1200 Rinehart Rd - BC04-002842 (FIRE ALARM) DOCUMENTSNov 15 04 12:04p Pit!j of Sanford Building 407 328 3859 P.1 I REVISIONS PERMIT &LA - DN a DA . TE ADDRESS. k QA, CONTRACTOR r c - PH # FAX # q0_1 - Z9 -7- 02 2- DESCPRITION OF I REVISION: ry)oadon A(4 and rea u -e n ew (IaAh 6�'eeTf� '4 - CITY OF SAN� UTILITIES NOV 1- 2004 FIRE ' JA BLDG ED CA,&f Saln4r ;If jl,),'7 -7 FLORIDA FIRE & SOUND, INC. 637 TRIUMPH COURT — ORLANDO, FLORIDA 32805 407-298-8812 FAX 407 297-5882 www.FloridaFireandSound.com EF 000 1162 DATE: 11/12/04 SUBMITTAL FOR: Seminole Power Sports 1200 Rinehart Road Sanford, Florida FIRE ALARM SYSTEM DESCRIPTION MANUFACTUREE MODEL NO. Fire Control Panel FCI 7100-21D Annunciator Panel LCD -71 00 Suppl ' Notif. Appliance Circuit SNAC-9 Manual Station MS -7A Smoke Detector ASD-PL2 Base ADB -FL Duct Detectorr ADP Sampling Tube ST -5 Remote Light RA40OZ Addressable Output Module AOM -2R Addressable Monitor Module AMM -2 Wall Horn Strobe 11 Ocd P1 224MC Ceiling Horn Strobe 11 Ocd P1 224MC Sync Module MDL Fire Protective Cable West Penn FPL -970 Fire Protective Cable FPL -972 Fire Protective Cable FPL -980 Fire Protective Cable FPL -982 Battery Elk ELK -1 280 Battery .1 . ELK -1 2120 By: —7zr;�— Sanford F 'Date: --,� FIRE ALARM * CCTV * N Fire Dept. Final Insp. Date�_ ACCESS* WTERCOM * BACKGROUND NIU!SIC Date: 11/12/04 Time: 2:13 PM 1 110-90001 ASD -PL Analog Photoelectronic Smoke Sensor 0.000 0.007 DUCT HOUSINGS, 12 121-90000 ACS -P200 Analog Duct Detector 0.004 0.004 ADDRIESSABLE M06ULES 3 190-00002 AMM -2 Addressable Monitor Mod, Cl "B" 0.001 0.021 6 190-90022 AOM -213 Addressable Output Relay Control Module 0.002 0.002 MANUAL STATi6rjis, 7 1100-0431 MS -7A Addressable double action station (AMM -MS mini -module included) 0.002 0.002 PROJECT NAME: Seminole Power Sports 1200 Rinehart Road Sanford, Florida Date: 11/12/04 Time: 2:13 PM GTY ,Part#. Model, Description 'StandbV.., Alarm Current Current a C "�ICATIONAPP'iANCES-"-.-," L F I NOTI SPECTRALERT�' SERIES HORNSiSTROBL8 P1 224MC Horn, Electronic, w/1 10 cd Strobe, red 0.000 0.876 P11224 I IVIC Ceiling Horn, Electronic, w/1 10 cd Strobe, red 0.000 0.438 P1 224MC Ceiling Horn, Electronic, w/1 10 cd Strobe, red 0.000 0.292 ACCESSORIES: POWER SUPPLIES 150-00012 SNAC-9 Supplementary Notification Appliance Ckt Panel 9 Amp W/ Sync 0.075 0.175 Total Supervisory Current, Amp Enter number of standby hours per NFPA for the specific installation Total Supervisory Capacity, A -H Total Alarm Current, Amp Enter Alarm period in minutes Total Alarm Capacity, A -H Total Alarm and Supervisory Capacity, A -H 0.075 '60 4.500 1.781 0.0833 0.148 4.648 . . ....... . 7, iZl Provide 8 AH FIRE CONTROL INSTRUMENTS UZI Building Intelligent Networks 7100SERIES www.firecontrolinstruments.com DESCRIPTION The FCI 7100 series fire alarm control panel is a multiprocessor-based,analcg addressable system in a compact, yet expandable, plat- form. Intended for commercial, industrial and institutional installations, it is ideal for life safety and property protection applications. Th e basic 7 100 series control panel p ro- vides two analog addressable signaling line circuits (SLCs). Each SLC supports up to 99 analog addressable sensors, as well as up to 99 addressable monitor modules and/or con- trol points.With 198 addresses available on each SLC, total system capacity reaches 396 a did resses.The 7 100 uses an advanced Pre - local that ensures an almost instant response to events while at the same time suppressing nuisance alarms. The system may be programmed with ei- ther theWindowsil-based Field Configuration Program (FCIP-71 00) or through a compre- hensive set of intuitive, securely Password protected front -panel programming options. This important feature allows the system to quickly adapt to any future requirements brought on by changes in Occupancies, build- ing remodels, or other contingencies. The sophisticated circuitry and powerful analog software enables the 7 100 series fire alarm control panel to read the specific sen- sitivity level of each sensor and compensate for any changes due to age, dust accumula- tion or other environmental factors.Th e 7 100 incorporates the FC] Listed Integrated SensitivityTesting (LIST) which meets NFPA 72 sensitivity testing and maintenance re- quirementsThe LIST testing allows subsmn- tial savings in both maintenance and service while virtually eliminating nuisance alarms. The Model 7 100-21D features an integral DigimlAlarnn CommunicatorTransmitter (DACT) with all popular transmission formats and a 16 -digit telephone number field, It is 8 - digit Carrier Information Code (CIC) compli- ant and also prevents"clialer-runaway" in the event of intermittent system faultsThe 7100- 2D is UL Listed for Remote Station, Propri- etary,and Central Station fire alarm systems. The 7 100 is housed in an attractive, con- temporary styled cabinet. It allows ample space for wiring and room for batteries up to 7A/H capacity. FEATURES Integrof DIgftaIA form Communicator (with the 7100-2D) 120 or 240YAC (optional) Input Line Voltage Intuitive Front Panel Programming o 80-characterAlpho-numeric Display Two Style 4 (Class"B") Signaling Line Cimuits.Style 6 (Class"A") with optional CACIM module Two Style Y (Class "B") Regulated Notification Appliance Circuits rated fo r I.SA mp. each. Style Z (Class"A") with optional CACIM module Suitable for Pre -Action Deluge applications with optional MCOM module I Available with Plastic orMetal Door PirriodicTrouble Reminder -Individual Sensor Drift Compensation Listed Integral SensitivityTesting (LIST) Dual -stage Maintenance alerts ("Dirty" and" Very Dirty") Multilevel Sensor Sensitivity Adjustments (Front Panel programmable) Daylilifight SensitivityAdjustments (Front Panel programmable) Alarm Verification per Individual Sensor PositiveAlarm Sequence for Sensors or ManitorModules Four Levels ofSystemAccess using Six Digit Passwords with up to Five User Passwords per Level A Duplicate and ExtroA ddress Indications ManchTime (60 or 120 BPM)/Temporol Pattern/ Coded FoursiCallfornia Code/ User-Deftned Zone Coding Cross Zoning System Configuration Programming and 500 Event Log stored in Non -Volatile Memory Fan Restart with Sequential Restart Delay Uploodi Download ol"Ponel Configuration between Panel and FCP-7 100 program (Password Protected feature) Up to 64 7 100 panels In NetS0L0" network with optional lNf-7100 module COMPACTANALOG ADDRESSABLE FIRE CONTROL PANEL (K) <,l SiB69 MEA 307-99-E 3 0 M9 - EV. 1. 11 05211, 7165.0694:�l 9 (7 100) 7300-0694i231 (LCD -7100) 7300-0694:241 (LDM-7100) An ISO 9001 Compan 1�1 1— 1. All Rlg­ R--d P- I A H.n.y­11 C.mp­y FIRE CONTROL INSTRUMENTS RiFloBuilding Intelligent Networia 7100 SERIES www.firecontrt)linstruments.com OPTIONAL ACCESSORIES LCD -7 100 The LCD -71 00 remote serial display offers an 80-chal- acter alphanumeric readout lbr remote display ofall sys- tem events. It duplicates all the information on the 7 100 series panel displw/ and pmvides key switch protected func- tions such as System ResefAlarmAcknowledge7rouble Acknowledge, Signal Silence,and Dril;Test. LEDs on the LCD -7100 indicateAlarm, Supervisory, Sys- temTrouble, Pbwer Fault,Systems Silenced, NAC# I,and N AC#2 Silenced conditions. The LCD -7 100 can be surface or semi -flush mounted on a standard four -gang electrical box and it can be in - smiled up to 4.000 feet (1,219 m) from the main control panel.The 7 100 series fire alarm control panel can sup- port up to five (5) remote LCD -7 100 annunciators using one pair of twisted, n on -shielded I BAWG min.wire for serial communication and another pair of 16AWG min. for operating voltage. (Refer to 9020-0486) LDM-7100 The LED Driver module (LDM-71 00) is designed to mount in a U.L. Listed remote annunciator and provides outputs for remote panel switches and 33 remote LEDs. Three LDM-7 100 modules may be installed in a single an- nunciator for a total of 99 LEDs per annunciator This combination may be repeated up to five times for a total offifteen (15) LDM-7 100 at up to five different locations. Maximum distances of up to 4,000 feet (1,219 in) can be achieved using one pair of twisted, non -shielded wire for serial communication and another pair ofstraight-lay wire. for operating voltage. (Refer to 9020-05 19) CAOM The Class"A" Optional module (CAOM) allows StyleY arid Z (Class"B" and"A") operation for, both Notification Appliance Circuits and Style 4 and 6 (Class"B" and"A") for both Signaling Line Circuit.. It also provides discon- nect switches for each signaling line circuit and a com- men disconnect Switch for both notification appliance cir CLuts. MCOM The Municipal Connection Option Module (MCOM) provides three choices of outputs. It can be configured as a Municipal Circuit (City Box) output at: - 24VDC nominal voltage -0.0018 amp supervisory current -0.5 10 amp maximum alarm current -35 ohms maximum line resistance - 14.5 ohms maximum trip coil resistance It may also be setto serve as a Reverse Polarity output with a nominal voltage output of 24VDC at 0.0 12 amp maximum alarm and supervisory current. The third option the MCOM provides is as a releasing solenoid output rated at: -24VDC nominal voltage 0.005 amp supervisory current 0.7 10 amp maximum alarm current -2 ohms maximum line resistance it is suitable to be used with: -Skinner I2V2LBX25 A Asto T82 I OA 107 Asco 82 1 OG207 Skinner 73218BN4UNLVNOC I I I C2 -Skinner 73212BN4TNLVNOC322C2 -Skinner 71395SN2ENJ I NCH I I I C2 PTRM The PrinterTransient module (PTRM) provides RS -232 Isolator/Transient protection for the 7 100's RS -232 port (BSM connector J2). It is used in conjunction with a serial printer applied to the RS -232 port for permanent record keeping. INI-71 00 The Intelligent Network Interface module allows the 7100 series fire alarm control panel to become the platform ofa peer -to- peer, token ring,selfregenerative network comprised of up to sixty-four (64) 71 00s. Sp-11 ­1 -id -d b, m bA -d .,,d ­ bl,li­ FIRE CONTROL INSTRUMENTS 16 5—h— P,,kW­­d,MA02090 USA - T.1:781-471-3000 - Nx:781-471-3099 A H.neywerl C.mp­y EH38FIRE CONTROL INSTRUMENTS 8wildingintelfigentNet—,k, wwwfirecontrolinstruments.com niH 11 , 0-t T81 TBZ TB3 T" r— — — — — — -- BSM 06 (7) 0 67 1 2 4 5 7 8 i —d . b� —d -- �1... -d — h. -.d . b� - d e, -- �, e 2-11 Righ- R.I.— d FIRE CONTROL INSTRIJ M ENTS 16 S—J-- NrkW­,00d, MA 02050 USA - T,1.781-471-3000 - hx: 781-471-3099 A C.mp..y 1- —1— � 3 1 1— 1 �11 FIRE CONTROL INSTRUMENTS 10[uilding Intelligent N,tw,&j 7100 SERIES www.firecontmlinstruments.com SPECIFICATIONS Primary Input Power Output Power Non-resettable Power Resettable Power Two (2) Notification Appl i ance Circuits Current 7100-2 (Two Loop) 7100-21D (Two Loop w/Dialer) LCD-7�00 LDM-7 00 INI-7100-UTP,-FO OperatingTemperature Relative Humidity Battery Charger Capacity Alarm &Trouhle Relay Contacts Dimensions 7100 LCD -7100 LDM-7100 Weight (7 100) AGENCYAPPROVALS U. L. File 5 1869 FM Approved CSFM 307-99-E 307-99-EVol.11 MEA 7 165-0694:219 (7100) 7300-0694:231 (LCD -7100) 7300-0694:241 (LDM-7100) 120VAC,50/60 Hz @ 2.0 amps or 240VAC,SO/60 H� @ 1.0 amp 4 amps. @ 24VDC (tocal) 1.0 amp. max. 1.0 amp. max. 1 1.0 amp. max. from both circuits 1. 5 am p- each @ 24VD C Superviso,y Alarm 0.065 amp. 0.085 amp. 0.085 amp. 0. 105 amp. 0.050 amp. 0.075 amp. 0.035 amp. 0.200 amp. (All LEDs lit) 0.040 amp. 0.040 amp. 32 - 120- F (0 - 49- C) 85 % (non -condensing) 3 1 A/H (Cabinet accommodates 7A/H Sim batteries) Form"C",2 amps.@ 24VDC (resistive) 16.9" H . 14.5"W . 3" D (40 . 37 x 7.5 c,n) 4.25 " H x 8,25"W x 1.88" D (1 1.5 x 20.5 x 4.6 cm) 6"W x 4 1/2"W (15.24 x 1 1.5 cm) 24 lbs ( I I kg) -o -d b� —d --N— p., ­- .,.d — b.1—d . b� i,� --, —, —. —-1 �. --, -- t, 2-11 R K—, -d FIRE CONTROL INSTRUMENTS 16 S,,Lt,w,,t P�rkVV,,t.,,d.MA 02090 USA - Tel!781-471-3000 - F,,: 781-471-3099 - —firecon—lins—m--c—, A ll—y—d C—p-y 1.2-11110113 1 ffir"Mr�mv FIRE'CONTROL INSTRUMENTS Building Intelligent Networkj 1100 SERIES www.firecontr-oIinstruments.com ORDERING INFORMATION BASIC KITS Part Number Model Description 00-�311 BK -7100-2 Basic System Kit,2 SLC (BSM,Keypad DisplayTransliormer) 00- 312 BK -7100-2D Basic System Kit w/ DACT2 SLC 1100-1313 BK -7100-2-240V Basic System Kit,2 SLC,240VAC 1 100-1314 BK -7100 -2D -240V Basic System Kitw/ DACT 2 SLC,240VAC CABINETS 1 100-1307 7100 -ENC -PLASTIC Enclosure with Plastic Door, standard (16.9" H x 14.4" D x 3" D) 1 100-1308 7100 -ENC -META L Enclosure with Metal Door, standard (16.9" H x 14.4" D x 3" D) 1 100-0480 NS -7100B Enclosure, NetSOLO", Broadband, black (19" H x 19"W x 4" D) 1 100-0481 NS-710OR Enctosure, NetSOLW Broadband,red (19" H x 19"W x 4" D) OPTIONALMODULES 1 100-0399 LCD -7100 Remote SerialAnnunciator (80 -character) 1 100-0428 LDM-7100 Remote LED Driver Module 1 100-1233 CAOM ClassA Option combination module with disconnect switches for both Signaling Line Circuits and NotificationAppliance Circuits 1 100-1234 MCOM Municipal Connection Option Module for Local Energy City Box, Reverse Polarity Signaling, or Releasing Solenoid 1 100-1235 PTRM PrinterTransient Module 1 100-0440 INI-7100-UTP Intelligent Netvvork Interface module- UnshieldedTwisted Pair 1 100-0439 INI-7100-FO Intelligent Network Interface module- Fiber Optic REPLACEMENT PARTS 1420-0429 EN -71 00 Enclosure (replacement) 1 120-0779 CS -7100 Plastic Door (replacement) 1 120-0867 CS -7100M Metal Door (replacement) 1 120-0778 T-71 00 Transiormer, 120VAC input (replacement) 1 120-0801 T-7100-240 Transbrmer,240VAC input (replacement) 1 120-0781 BSM -2 Basic System Module, 2 SLC (replacement) 1 120-0780 BSM -2D Basic System Module,2 SLC vv/DACT (replacement) 1 120-0767 KeypadAssembly (replacement) Sp-ir. p—d ------- I FIRE CONTROL INSTRU MENTS 16 S ou th we s t Ph rk.We s two o d, M A 02090 USA - Te 1: 78 1-471- 3 000 - h : 781 -471.3 09 9 - www.fi re co n t ro I in s I r, me,, - c, m A 11.neyw.11 Co.p.ny 9020 0466NER. 2�3 / Pq� 5 d S IIIIIIIIIN E FIRE CONTROL INSTRUMENTS il FIRECONTROLINSTRUMENTS.COM DESCRIPTION . The LCD -7100 Remote Serial Display provides superior flexibility to the 7100 Series installations. It features an. 80 -character display which duplicates all the information on the 7100 Series panel display with the exception of menus, The LCD -71 00 contains the following function keys: Alarm Acknowledge Trouble Acknowledge Signal Silence System Reset/Lamp Test System Drill Test A keylock must be placed in the "ON" position to enable the function keys with the exception of the "Trouble Ac- knowledge" key which is used to silence the trouble sounder on the LCD -71 00. LEDs on the LCD -7100 are: Alarm Supervisory System Trouble Power Fault System Silenced NAC #1 Silenced NAC -1"12 Silenced INSTALLATION The LCD77 100 can be surface or flush mounted on a stan- dard -four -gang electrical box and installed up to 4,000 feet away from the main control. The 7100 Series control panel can accommodate up to five (5) remote LCD -7 100 annuncia- tors. APPROVALS UL S1949 FM 3006578 CSFM NYC -MEA 7100 SERIES tL,CD-7100 REMOTE SERIAL LCD DISPLAY FEATURES 80 -Character LCD Display Full Complement of Function Keys and LEDs Remote Location up to 4,000 Feet Away from Control Panel 7100 Series will Accommodate up to Five (5) Annunciators Surface or Flush Mount on Standard Four -gang Electrical Box Compact, Attractive Appearance SPECIFICATIONS Operating Voltage 24 VDC (nominal) Supervisory current .050 amp. Alarm current .075 amp, Operating tempe rature (recommended) 60 to 80' F (15 to 27' C) Absolute maximum operating temperature range 32 to 120" F (0 to 490 Q Relative humidity 85% max., non -condensing at 90' F (320 C) Dimensions 8 '/4"L x 4 1/2" H x 1 7/8" D (20.5 x 11.5 x 4.6 cm) ORDERING INFORMATION Part No. Model Description 1100-0399 LCD -71 00 Remote Serial LCD Display Specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice, (D 1999 All Rights Reserved 16 Southwest Park, Westwood, MA 02090 USA TEL: (781) 471-3000 FAX: (781) 471-3099 An ISO 9001 Cenified Company 9020-0486 /Ver. 1.4 ��FIRE CONTROL INSTRUMENTS ASB=PL2 by:Honey"11 www.firecontrolinstruments.com ANALOG, ADDRESSABLE PHOTOELECTRONIC lei =1 i! I 4.11T-11 I The FCI Series analog addressable plug- in smoke sensors with integral communi- cation provide features that surpass con- ventional sensors. Sensitivity can be pro- grammed in the control panel software, and is continuously monitored and reported to the panel. Point ID capability allows each sensor's address to be set with decade address switches, providing exact loca- tions for selective maintenance when chamber contamination reaches an unac- ceptable level. The ASD-PL2 photo- elec- tric sensor's unique optical sensing chamber is engineered to sense smoke produced by a wide range of combustion sources. Dual electronic thermistors add 135'F (57'C) fixed -temperature thermal sensing on the ASD-PLT2. INSTALLATION ASD-PL2 plug-in sensors use a sepa- rate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug in and re- move detectors without using a ladder. Mount the base on a box which is at least 1.5" (3.81 cm) deep. Suitable mount- ing base boxes include: * 4.0" (10. 16 cm) square box. * 3.5" (8.89 cm) or 4.0" (10.16 cm) oc- tagonal box. * Single -gang box (except relay or isola- tor base). * With B501BH base, use a 4.0" (10. 16 cm) square box. * With B224RB or B224BI base, use a 3.5" (8.89 cm) octagonal box, or a 4.0" (10.16 cm) octagonal or square box. NOTE: Because of the inherent supervi- sion provided by the SLC, end -of -line resistors are not required. Wiring 7 -taps" or branches are permitted for Style 4 (Class "B) wiring. FEATURES • Sleek, low -profile design. • Analog Addressable communica- tion. • Stable communication technique with noise immunity. • Low standby current. • Rotary 01 to 99 address switches • Optional remote, single -gang LED Indicator (RA400Z). • Dual LED design provides 360 viewing angle. • Visible red LEDs flash every time the detector is polled, and light steadily on alarm. • Built-in functional test switch activated by external magnet. • Optional relay, isolator, orsounder bases. - Listed to UL 268. DETECTOR SPACING: FCI recommends spacing sensors 'in compliance with NFPA 72. In low airflow applications with smooth ceilings, space sensors 30 feet (9.144 m). For specific information regarding sensor spacing, placement, and special applications, refer to NFPA 72. System Smoke Detector Application Guide, document A05-1003, is available at www.systemsensor.com. SMOKE SENSOR ASD-PL2 ASD-PTL2 LISTEO a <a> APPROVED An ISO 9001 ComDan Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no respon- sibilityis assumed by Fire Control Instruments for their use Specifications subject to change without notice. 0 2003 All Rights Resenied 9020-0559tver. 1.2 Page 1 of 2 Fed Asn=PI9 by Honeywell REMOTE ANNUNCIATOR + + — — — — — — — — — — — — - Listed Compatible CONTROL 2 2 PANEL 03 3 -------------------------------------------- OPTIONAL RETURN LOOP ------------------------------------------------------- SPECIFICATIONS Size: 2. 1 " (5.1 cm) high x 4.1 " (110.4 cm) diameter installed in B501 base, 6.1 " (15.5 cm) diameter installed in ADB -FL base. Shipping weight: 5.2 oz. (147 g). Operating temperature: ASD-PL2- O*C to 49'C (32'F to 120*F); ASD-PTL2- O'C to 38*C (32*F to 1 00'F). Low-temperature signal forASD-PTL2 at 45'F/7.22'C (+/— 1 O'F/5.54'C). UL -Listed velocity range: 0 — 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% — 93% noncondensing. Thermal ratings: fixed -temperature setpoint 135'F (57'C). ELECTRICAL SPECIFICATIONS Voltage range: 15 - 32 volts DC peak. Standby current (max. avg.): 250 pA @ 24 VDC (without communication); 360 pA @ 24 VDC (one communication every 5 seconds with LED enabled). LED current (max.): 6.5 mA @ 24 VDC ("ON"). BASES AVAILABLE B21OLP: 6.1" (15.5 cm) diameter. B501: 4.1 " (110.4 cm) diameter. B501 BH or B501 BHT: Sounder base assembly (13501 BHT produces a temporal pattern). Includes B501 base. B224RB Relay Base: Screw terminals: up to 14 AWG (2.0 MM2) . Relay type: Form -C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). B524BI Isolator Base: Dimensions: 6.2" (15.748 cm) x 1.2" (3.048 cm). Maximum: 25 devices between isolator bases. Specifications are provided for information only, and are not intended to be used for installation purposes and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments for their use. Specifications subject to change without notice. C2003AII Rights Reserved FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA - Tel: 781-471-3000 - Fax: 781-471-3099 - www.firecontrolinstruments.com A Honeywell Company 9020-0559/Ver. 1.2 / Paoe 2 of 2 EY1'FIRE CONTROL INSTRUMENTS B'un1jhg.1ab@1Zfg=tNeWoAs www.firecontrolinstruments.com DESCRIPTION The Fire Control Instruments ADP Low_ Flow Series photoelectronic air duct smoke sensors are capable of sensing smoke in air velocities from 100 to 4,000 feet per minute (0.5 to 20.32 m/sec). The ADP series features low -flow tech- nology that enables duct smoke detection throughout a broad range of airflow environments. Many difficult to solve HVAC applications occur in low airflow duct applications where reliable smoke detection is critical. ADP low -flow tech- nology can detect smoke at air speed ve- locities of 100 feet per minute or greater, while continuing the same reliable perfor- mance to 4,000 feet per minute. The ADP Series sensor samples air cur- rents passing through a duct and gives de- pendable performance for shutdown of fans, blowers, and air conditioning systems, pre- venting the spread of toxic smoke and fire gases through the protected area. These intelligent sensors communicate and are continuously monitored through the signaling line circuit. Sensor sensitivity changes caused by dirt, temperature, or humidity are reported to the panel, allow- ing compensation algorithms to maintain the sensor's set sensitivity. An advance indication at the panel specifies the sen- or address, allowing for selected main- tenance to be performed as needed. Remote alarm annunciation can be accomplished by using the RA40OZ Re- mote Annunciator or the RTS451 or RTS451KEY Remote Test Station. Both these devices allow testing of the sensor from a remote location, The ADP series low -flow duct sensors are designed for simplified installation and easy maintenance. The modular construc- tion allows for easy cleaning and uncom- plicated field replacement of the UL rec- ognized power and sensor boards. AUP Series The ADIP (non-rela y) has outputs for a remote LED display and remote test switch. It incorporates zener diodes to con- serve power for commu nications to other devices. The ADP is a 2 -wire device that requires signaling line circuit power only. The ADP -R (with relay) has powered outputs for remote LED indication with a remote test switch and audible sounder. Two form "C" auxiliary contacts can be configured as a relay version or jumpered to mimic the non -relay version. It has a patented cover tamper trouble signal. The ADP -R is a 4 -wire device that requires both signaling line circuit power and either 24VAC/DC or 120/240VAC for proper op- eration. FEATURES Air Velocity rating from 100 to 4000 feet per minute (0.5 to 20.32 mIsec.) Patented Telescopic Sampling Tube Easily accessible Code Switches Outside Mounting Tabs Easy and quick mounting to Round or Rectangular Ducts from V- 12' (0.3-3.7 meters) wide Easy to clean UL Recognized Field -replaceable Power and Sensor boards Transparent Cover for convenient Visual Inspection UL 268A listed ANALOG, ADDRESSABLE LOW -FLOW DUCT SENSOR 2-J, In, 0. ADP MRN ADP -R L A An ISO 9001 Compan -1 ARRIg-s— A Honeywell Company FIRE CONTROL INSTRUMENTS COMMUNICATION L04E Ul LISTED CONTROL PANEL ADP Series I ST DETECTOR 2ND DETECTOR IN LOOP IN LOOP Wiring diagram for ADP Duct Smoke Sensor using a LIL Listed control panel 41 00 AUP nA40OZ Wiring diagram for ADP Duct Smoke Sensor with optional RA40OZ (Must break tab on back of RA40OZ when used with ADP.) ADP tOMMON ATS45IMTSMIKEY FOR RTS46I.TERMINAL.3 IS NOT USED. (I'll S451 DDES NCI HAVE A YERMINAL 64 FOR RT8461KEY, TERMINA1.8, 7AND C, ARE NOr USED - Wiring diagram for ADP Duct Smoke Sensor with RTS451/RTS451KEY 02MMm,h%R..d FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA02090 USA - Tel: 781471-3000 - Fax: 781-471-3099 - www�flrecontmlimstmments.com A Honeywell Company 90-- lo L-M2 ­_,1 FIRE CONTROL INSTRUMENTS k wilt'antm...A. AUP Series COMMUNICATION . . ... ... LINE ............ 11 tj EM C j, LIVED r . ....... 61 r�_ . Q - .] = PANEL .11JUMPE—f ISTOETECTOR J1 JUMPER . 2ND DETECTOR lu,Lobp IN Loop Wiring diagram for ADP -R Duct Smoke Sensor using a UL Listed control panel NOTE: Jumper J1 shunt must be installed for 2—ire applications. J1 shunt must be removed for power PCB supervision. RA4MZ W'Wn WVA-YAOG14110�,W Wiring diagram for ADP -R Duct Smoke Sensor with optional RA40OZ .. ........... ik' mg- T�n'r4k S ANO,� ME NOT USED. Wiring diagram for ADP -R Duct Smoke Sensor with RTS451/RTS451KEY S .'x-- nd — b W — ­—nd— -w 0 W ww­ FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA - Tel: 781471-3000 - Fax: 781-471-3099 - —fireconlrolinstru—t,-m A Honeywell Cornpany FIRE CONTROL INSTRUMENTS 'B"'al'ing J) talLi;" tH so, 0A, AUP Series ADP SERIES LOW -FLOW SPECIFICATIONS Operating Temperature Range 32* to 131'F (0' to 55*C) Operating Humidity Range r Storage Temperature Range -22* to - 1 58'F 00' to +70' C) 117) ....... ... ADP: 5 � Alaurn Signal ADP -R: 3.90lbs. (1.8 kg) t 7 - AW. Po.ef I-) Width . ..... . .... ........... ................. ........... _J Wiring diagram for ADP -R Duct Smoke Sensor with optional PA400 Wiring diagram for ADP -R Duct Smoke Sensor with optional RA40OZ .. ........... ik' mg- T�n'r4k S ANO,� ME NOT USED. Wiring diagram for ADP -R Duct Smoke Sensor with RTS451/RTS451KEY S .'x-- nd — b W — ­—nd— -w 0 W ww­ FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA - Tel: 781471-3000 - Fax: 781-471-3099 - —fireconlrolinstru—t,-m A Honeywell Cornpany FIRE CONTROL INSTRUMENTS 'B"'al'ing J) talLi;" tH so, 0A, AUP Series ADP SERIES LOW -FLOW SPECIFICATIONS Operating Temperature Range 32* to 131'F (0' to 55*C) Operating Humidity Range 10% to 93% relative humidity (non -condensing) Storage Temperature Range -22* to - 1 58'F 00' to +70' C) Duct Air velocity 100 - 4000 ft./min. (0.5 - 20.32 m/s) Shipping Weight ADP: 3.35lbs. (1.5 kg) ADP -R: 3.90lbs. (1.8 kg) Length 14-3/4" (37 cm) Width 5-1/2" It 4 cm) Depth 2-3/4" (7 cm) ADP SPECIFICATIONS Voltage Range 15 to 32 VDC Standby Current 300pA @ 24 VDC (one communication every 5 seconds with LED flash enabled) Accessory Current Loads Device Standby Alarm RA40OZ OmA 10 mA Max. RTS451 /RTS451 KEY OmA 7.5 mA Max. ADP -R SPECIFICATIONS Current Requirements (using no accessories) Power supply voltage: 20-30VDC 24 VAC, 50-60HZ 120VAC, 50-6OHz 220/240 VAC, 50-60Hz Max. standby current: 26 mA 65 mA RMS 44 mA RMS 25 mA RMS Max. alarm current: 87 mA 182 mA RMS 52 mA RMS 30 mA RMS Alarm response tim:e 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. 3 to 10 sec. Power up time: 2 sec. 2 sec. 2 sec. 2 sec. Contact Ratings Alarm auxiliary contacts* (DPDT) 10 A @ 30 VDC 10 A @ 277 VAC (0.75 power factor) 240 VA @ 249 VAC (0.4 power factor) 1/8 HP @ 120 VAC 1/4 HP @ 240 VAC Supervisory contact IS PST) 2.0 A @ 30 VDC (resistive) *Minimum switching current for auxiliary contact must be 100 mA DC minimum 5 VDC. Accessory Current Loads at 24 VDC Device Standby Alarm PA400 0 mA 15 mA Max. RA40OZ OmA 12 mA Max. RTS451/RTS451KEY OmA 10 mA Max. P­nd.. .1— b FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA 02090 USA - Tel: 781-471-3000 - Fax: 781-471-3099 - www.firecontrolinsfirUrnents.corn A Honeywell Cmpany ff'-'Yl'F'IRE CONTROL INSTRUMENTS B.'Wj'q' Mtan#_tN...&' ABP Series ORDERING INFORMATION Part N Description Remote test station Analog addressable low -flow photoeiectronic non -relay duct smoke sensor ADP -R Analog addresable low -flow photoelectronic with relay duct smoke sensor ST -1.5 Metal sampling tube duct widths V-2' ST -3 Metal sampling tube duct widths 2'-4' Replacement filters Metal sampling tube duct widths 4'-8' ST -10 Metal sampling tube duct widths 8'- 12' A5053 Replacement photoelectric sensor board A5060 Replacement power board for ADP -R (w/relay) A5067 Replacement power board fprADP (w/o relay) Accessories Description RTS451 Remote test station RTS451KEY Remote test station w1key ^'—RX4ddZ__- Remote LED P460 Mini -Alert' Sounder- Note: Device cannot be wired directly to ACID (non -relay). F36-09-11 Replacement filters M02-04-00 Test magnet P48-21 -00 End cap for metal sampling tube P48-61 -00 End cap for plastic sampling tube S08-39-01 Replacement photo insect screen TBO-71-00 Replacement plastic sampling tube S�ffi­ spm�Wn­edt­.�­­ 0-aefta- FIRE CONTROL INSTRUMENTS 16 Southwest Park, westwood, VA 02090 USA - Tel: 781-471-3000 - Fax: 781-471-3099 - www.fireconholinstruments,com A Honeywell Company FIRE CONTROL INSTRUMENTS WWW.FIRECONTROLINSTRUMENTS.COM DESCRIPTION The Addressable Output Relay Control Module (AOM -2R) allows an FC1 analog addressable fire alarrn con- trol to switch discrete relay contacts by code command. The relayprovides two (2) isolated sets of Form -C contacts which transfer simultaneously. Circuit connections to the relay con- tacts are not supervised by the module. TheAOM-2Rmodule is designed for installation in the sig- naling line circuit of any FCI analog addressable control panel, The signaling line circuits of FCT analog addressable control panels are designed to accommodate up to 98 control modules per circuit. The module contains a panel controlled LED. The AOM -2R is designed to mount in a 4" square j unction box 2 1/8" deep. AGENCY APPROVALS UL S1949 Factory Mutual 3006398 CSFM NYC -MEA A.OM-2R � (R ADDRESSABLE OUTPUT RELAY,� CONTROL MODULE APPROVED FEATURES Two (2) Sets of Form "C" Contacts Compact Size Allows Easy Installation aw - p, Current Rating__ Maximum Volta2e Load Description b; tion pjL _a____ 3A 30 VDC Resistive Non Coded 2A 30 VDC Resistive Coded 0.9A 110VDC Resistive Non Coded 0.5A 125 VAC Resistive Non Coded 0.5A 30 VDC Inductive (L/R=5ms) Coded IA 30 VDC Inductive (L/R=2ms) Coded 0.5A 125 VAC Inductive (PF=.35) Non Coded 0.7A 75 VAC Inductive (PF=.35) Non Coded TECHNICAL INFORMATION Supervisory current .00030 amp. Alarm current .00030 amp. Operating temperature 32 to 1200 F (0 to 49) C) Relative humidity 10 to 93% relative humidity (non -condensing) Dimensions 4 1/2" IJ x 4" W x 1 1/4" D ( 3.3 x 5.5 x 1.25 cm) ORDERING INFORMATION Part Number Model Description 190-90022 AOM -2R Addressable output relay control module I ec,�,calcon, n,,,,ti ended to be used for installation PUMOSes. and are believed to be accurate. However. no responsibility is assamed by Fire Control In- st nen" for 'bri, u, c R ina a vithout notice.- CD 2001 All Right, RE,E,,ed 16 Southwest Park, Westwood, MA 02090 USA TEL: (7811) 471-3000 FAX: (781) 471-3099 An ISO 9001 Certified Corepany 9020-0520,,,Ver. 1.2 0 FIRE CONTROL INSTRUMENTS DESCRIPTION The Addressable Monitor Module AMM -2 features a single Style B, Class B initiating circuit with end of line resistor. This module provides an address for any device or group of devices connected to this circuit. Any alarm initiating devices with nor- mally open (N.O.) dry contacts, such as heat detectors, linear heat detection devices, projected beam smoke detectors, 4 -wire smoke detectors, water flow switches, tamper switches, manual stations, etc. may be installed in this circuit. The AMM -2 module is designed for installation in the signal- ing line circuit of any FC1 analog addressable control panel. The signaling line circuits of FC1 analog addressable panels are designed to accommodate tip to 99 monitor modules per circuit. The initiating circuit of the AMM -2 has a maximum line resis- tance of 1,200 ohms, allowing the module to accommodate a substantial number of initiating devices located at consider- able distances from the module. The compact size facilitates the installation of the module in- side manual stations, or mounting boxes of various types of alarm initiating devices. AGENCYAPPROVALS tL S1949 IM OVOA4.AY NYGMEA MEA427-91-EVol.111 ICSFM Approved U(D L AMM -2 ) ADDRESSABLE MONITORMODULE AWROWD FEATURES - Compact Size Allows Easy Installation - Class B, Style B Initiating Circuit 0 1,200 Ohm Line Resistance for Initiating Circuit - Accommodates any N/O Dry Contact Device TECHNICAL INFORMATION Supervisory current .0004 amp. Alarm current .0006 amp. Operating temperature 32 to 120'F ( 0 to 49, Q Relative humidity 10 to 93 % (non -condensing) Dimensions 1.3" H x 2.75" W x 0.5" D (3.3 x 5.5 x 1.25 cm) ORDERING INFORMATION Part Number Model Description 190-00002 AMM -2 Addressable Monitor Module, Single circuit, Style B, Class B Specifications are provided for information only, are not intended to be used for installation purposes, and are believed to be accurate. However, no responsibility is assumed by Fire Control Instruments, Inc. for their use. Specifications subject to change without notice, c2000 All Rights Reserved 301 2nd Ave Waltham, MA 02451-1133 USA TEL: (781) 487-0088 FAX: (781) 3 70-4132 9020-0502Ner. 1.0 FIRE CONTROL Slystem Sensor INSTRUMENTS SpectrAlert Sevies Operates on either -12 VDC or 24 VDC www.firecontrolinstruments.com WidestRange ofCandela Options: to SELECTABLE OUTPUT 1211., 15 amd 15175 candela STROBES AND HORNS Description MODELS P.1224MC,.- The System Sensor Spectralert' select- 17/a" backbox using the universal mount- S1224MC able output strobes and horn/strobes offer ing plate included with each Spectralert enhanced features that include the widest unit. range of Gandela options available,and the An optional strobe sychronization mod - capability to recognize and self -adjust for ule is available for compliance the Ameri- either 12'or 24 volt operation. cans with Disabilities Act (ADA). The MDL Spectralert selectable candela wall- (red) MDLW (white) synchronizes the mounted strobes and horn/strobes offer strobes at 1 Hz and the horns to a tempo- fi key performance features long associated ral 3 coded pattern. The synchronization with the Spectralert name. The selectable modules mounts on a 4 '74' x 4 x Al candela strobes and horn/strobes offer av- 2 'A" backbox and supports two (2) Style erage current draws that are not only Y (Class B) or one (1) Style Z (Class A) lower than conventional fixed -candela notification appliance circuit. A separate Spectralert products, but also lower horn control input is available to allow than similar products by others. By con- silenceable audible devices and non- suming less current, the ability to con- nect even more devices per circuit is pos- silenceable visual devices on the same pair or wires. sible, resulting in lower installed cost. Spectralert selectable candela strobes and horn/strobes offer the same installation - friendly features synonymous with the Spectralert name, such as the option of 2- and 4 -wire operation; the ability to use standard size backboxes with no encroach- ment into the box; and universal mounting incorporating the labor-saving QuickClick- feature. Such labor-saving features make wire connections simple and fast, further reducing installed cost. These strobes and horntstrobes offer the broadest range of candela options. In ad- dition, they can operate�on either 12V or 24V with no settings required. The device recognizes and self -adjusts to the correct current automatically. Temporal 3 or con- tinuous tone options continue to be avail- able, in either an electro -mechanical or 3 kHz pattern These strobes and horn/strobes incor- porate the same stylish, low profile design of the conventional Spectralert products, for a consistent and aesthetically pleasing appearance across the entire product line. The selectable strobe and horn/ strobe is available in either red or white. Thedevicesmountona standard4"x 4"xll/2"backboxorasinglegang2"x4"x Features Operates on either -12 VDC or 24 VDC WidestRange ofCandela Options: to 1211., 15 amd 15175 candela � 24V., 15,15,75,30,75 110candela i Easy Candela Selection Easy DIP Switch Selection for Horn Options Eask Mounting with QulcJ�Clfckl Synchronization avalable with optional MDL Sync�Clrcult- module < Meets UL1971, NFPA72, and ADA Signaling ReqEdrements MEA An ISO 9001 Comoanv �._'Al 1,.104 A Honeywell Company FIRE CONTROL INSTRUMENTS Strobe only Horn/ Strobe 15 cd: Horn/ Strobe 30 cd Sound output guide SpectrAlert Selectable Ouput Strobe and Horn/Strobe Spectralert Current Tables Horn/ Strobe 75 cd Horn/ Strobe 15175 cd: Horn/ Strobe 110 cd: * This tone only suitable for pilvate mode use at rated voltage tested by UL. FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, VIA 02090 USA - Tel: 781-471-3000 - Fax: 781-471-3099 - www�firecontmlinstruments.com A Honeywell Company W�M6-­ 1.1 1 1�2d' a SpectrAlert 1zFIRE CONTROL Selectable Ouput INSTRUMENTS Bu,g1!3gJbWn4entNobv­ks Strobe and Horn/Strobe Strobe only: lllllm�m� WMIMNIMMMEMMM�Mmmm a mmmmmamomol mmmmommmmomm Mo Mmmmm=Mm MM MMEOMMEM IMMIMMIMMM01 Horn] Strobe 15 cd: Current measurements (Average RMS method) NOTE: The 12V 15/75 cd strobe was tested at the 9.5-17.5 volt-FWP/DC limits. All other 12 V strobes were tested at the 8-17.5 volt-FWR/DC limits. All 24V strobes were tested at the 16-33 volt-FWR/DC limits. This does not include the 80% low end or 110% high end voltage limits. Hom/ Strobe 15/75 cd: Moo = WE N no =M=mmi Horl Strobe 30 cd: Horn/ Strobe 75 cd: Em moon moon OM M mo mom Memo m on oino om E a!= M ommomm Horn/ Strobe 110 cd: NEWN-WE MW Moo FIRECONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA02090 USA - Tel: 781-471-3GOO - Fax: 781-471-3099 - wwwfireconholinstruments.com A Honeywell Company EFIRE CONTROL INSTRUMENTS ?3'B'.M,hgMW2Z#antN.tv..ks Specifications Walk Test SpectrAlert horn/strobe and horn only work on 1� walk tests" with time durations of4 seconds or greater Input terminals 12 to 18 AWG Dimensions Strobe and horn/strobe with universal plate 5" x 5 5/8" x 2 15/is" Strobe and hom/strobe with small footprint plate 3 3/s" x 5 sh" x 2 clis" Hom with universal mounting plate 5" x 5 5/a" x 1 5/16" Horn without mounting plate 2 `hs" x 5'/11," x 1shli" Weight, horn only 7.2 Oz. Weight, strobe and hornistrobe &8oz. Ordering Information SpectrAlert Selectable Ouput Strobe and Noru/Strobe Mounting 4" x 4"x 1 1/2" or 2" x 4" x 17/6" standard boxes Indoor operating temperature 32'F to 120'F (O*C to 49'C) Maximum humidity 95% as tested per UL464 Weatherproof (horn and horn/strobe) Operating temperature 32*F to 150'F (O'C to 6l (outdoor strobe only) -40'F to 158*F (-40'C to 70*C) Voltages 12 or 24VDC and FWR unfiltered Operating Voltage Range* 12V: 10.5-17V 24V: 20-30V Operating Vbl�ge Range (with Sync -Circuit module MDL) 12V: 11-17V; 24V: 20-30V * These products should be operated within their rated voltage range; UL does test functional integrity to -20% and �10% of manufacturer's stated ranges. Red W hib, C—d.� Avg.— Av,­A- , 0 N—.VDC 0 K.. VDC-- 1`122414- .224MCW 12/-A -r­bl� 1q,15/75,30,75,11011 T..22�IC a224MC14 12�'14 A—i- S�­��Moduh ADL ADfN 12/2,t NA 1D/11 22/15 Sr. &11�tpmi M'"Iting P- Ji 9+1 P sm� N A N A NA X ­� Bo� �xt bBS BB91 NA A NA NP, U­.1M­l±qPat. D�P D�w 1 A N A NA NA hpl— en�' H- SPWffl_..rj._ N.—t—, FIRE CONTROL INSTRUMENTS 16 Southwest Park, Westwood, MA02090 USA - Tel; 781-471-3000 - Fax: 781-471-3099 - wwwfirecontrolinstruments.com A Honeywell Company I I I ­. _. _VV RATING - UL listed NEC type FPL inch �vrn inch - Constructed in accordance Egg with UL standard 1424 961 1 16 Solid .091 2.31 Black, Green, Brown, White, - Complies with UL 1581 4.1 QX Red, Orange, Vertical Tray Flame Test 962 1 14 Solid .020 .51 .104 2.64 Yellow - Temperature range: 2.6 QX 1 —20' C to 105' C Standard spool size 1000 feet dry locations - Meets 300 volt requirement nt c arifind in KIP Artirin 7CZA Standard spool size 1000 feet r APPLICATIONS Indoor (non—conduit per NEC) for: - Power— Limited Fire Protective Circuits WEST PENN WIRE /CDT--<- 61 Ell �E"A a F "' af? ANI,11,;A 0. 'dz 18 Solid _0110 Red, White, 6.5 QX Orange, Brown, Blue, Black 16 Solid ' E White, Red, Black 4.1 QX 14 Solid White, Red, Black 2.6 QX 'HEM 12 Solid White, Red, Black Standard spool size 1000 feet r APPLICATIONS Indoor (non—conduit per NEC) for: - Power— Limited Fire Protective Circuits WEST PENN WIRE /CDT--<- 61 Power -Limited Multiple Conductor/Unshielded 988 10 18 Solid .010 .25- .020 .51 .294 SPECIAL NOTES DESCRIPTION 6.5 QX • Select cables are available in ASTM bare copper PVC insulation - Twisted pair or 990 1 cabled construction - PVC fillers as required Polyester binders as required - Overall 75' C PVCjacket 1�;TINO Pair .010 .25 .020 .5 .165 See AquasealO product line I 4.1 Q/M' • UL listed NEC type FPLR I • Constructed in accordance with 992 4 16 Solid .010 .25 .020 .51 .213 • Orange ripcord underjacket UL Standard 1424 4.1 QX inch rru�_ inch mm inch n1m • Complies with UL 1666 Vertical 1 1084 6 22 Solid .010 .25, .020 .51, .179 Shaft (riser) Flame Test 2.6 QX 17.5 Q/M' Green, White or Yellowjacket 700 4 • Temperature range-, .012 1086 8 22 Solid .010 '.25 .020 .51 .193 4.90, - 20 * C to 75 0 C dry locations 17.5 Q/M' 998 1 12 Solid - .012 • Meets 300 volt requirements as . rO2 5 - 980 1 18 Solid .010 25" .020 '.51 .156 3'06, specified in Section 760 of the NEC Pair 6.5 LVM' COLOR CODE APPLICATIONS Standard spool size 1000 feet 982 4 18 Solid .010 .25 .020 .51 .188 4.78, Indoor (non -conduit per NEC) for: 6.5 f2/M' • Audio circuits 984 6 18 Solid .010 .25 .020 �.51 .224 5.139', • Control circuits 6.5 n/M' • Initiating circuits 986 8 18 Solid .010 .25 .020 -_51," .252 40 • Notification circuits 6.5 K2/M' Al 1 1 Black 6 1 Yellow 2 Red 7 Purple 3 Brown 8 Green 4 Blue 9 Red/Black 5 Orange 10 Red/White 50 --V- WEST PENN WIRE /CDT JACKET: Red 988 10 18 Solid .010 .25- .020 .51 .294 SPECIAL NOTES 6.5 QX • Select cables are available in 990 1 16 Solid 1 outdoor and direct burial versions. Pair .010 .25 .020 .5 .165 See AquasealO product line I 4.1 Q/M' I for details 992 4 16 Solid .010 .25 .020 .51 .213 • Orange ripcord underjacket 4.1 QX • Catalog No. 980, 982, and 990 994 1 14 Solid .012 30 .025 -.64- .205 are also available with a Blue, Pair 2.6 QX Green, White or Yellowjacket 700 4 14 Solid .012 '30, .025 1 64 .250 2.6 K2X 998 1 12 Solid - .012 TO . rO2 5 "".64',- .235 Pair 1.8 f2/m, COLOR CODE Standard spool size 1000 feet 1 1 Black 6 1 Yellow 2 Red 7 Purple 3 Brown 8 Green 4 Blue 9 Red/Black 5 Orange 10 Red/White 50 --V- WEST PENN WIRE /CDT JACKET: Red , ELK- 1280 Sealed Lead Acid Battery Sealed Lead Acid Battery 1EIK-1280 ) 12 Volts, 8 Ah ELK Sealed Lead Acid Batteries are excellent for the following applications with regard to size, Amp hour rating, and proper terminal connections: battery backup (for Access Control Systems, Fire Alarm Systems, and Security Alarm Systems), emergency lights, lighted exit signs, and uninterruptible power supplies. SPECIFICATIONS: • Nominal Voltage: 12 Volts • Rated Capacity: 8 AH (20 hour rate) • Length: 5.94" (151 mm) • Width: 2.56" (65mm) • Height: 3.74 (95mm) • Total Height: 3.98" (110 1 mm) • Weight: 6.17 lbs (2.8kg) - Terminals: F1 -Faston Tab No. 187, U.L. Recognized Two Year -Warranty ELECTRICAL SPECIFICATIONS: 20 hour rate (0.375A) 8AH Capacity 10 hour rate (0.71A) 7.1AH 77'F(25 -C) 5 hour rate (1.27A) 6.37AH 1 hour rate (4.5A) 4.5AH Internal Resistance, 1 Omn Fully Charged Battery (77'F) 104-F (40-C) 102% Capacity affected by 77-F (25-C) 100% Temperature (20 hour rate) 32-F (0-C) 85% 5-F (-15'C) 65% Cycle: Initial Charging Current less than 2.25A Charge Constant Voltage Voltage 14AV - 15.OV at 77'F(25'C) I Standby: Voltage 13.5V - 13.8V at 77'F(25'C) http://www.elkproducts.com/products/elk- I 280.htm Page I of 2 11/12/04 ELK- 1280 Sealed Lead Acid Battery �Dbebarge Churacteristits (WC, 6rF) U 10 .12 Q ) tL— ' L --L--L . .......... 5 10 20 30 66 2 3 5 10 " 10 �Wice 1,6 is 30 Discbne Time Discharge Current To order the ELK -1280 Call your nearest distributor or ELK at 1-800-797-9355 for more information (,:Imrwcftr*fics MC/32"F, 7 [ Home ] ELK Products, Inc. P.O. Box 100, Hildebran, N.C. 28637 USA (828) 397-4200 Copyright@2004 All rights reserved Terms and Conditions http://www.elkproducts.com/products/elk- 1280.htm Page 2 of .2 11/12/04 , ELK- 12120 Sealed Lead Acid Battery ELK -12120 12 Volts, 12 Ah ELK Sealed Lead Acid Batteries are excellent for the following applications with regard to size, Amp hour rating, and proper terminal connections: battery backup (for Access Control Systems, Fire Alarm Systems, and Security Alarm Systems), emergency lights, lighted exit signs, and uninterruptible power supplies. SPECIFICATIONS: • Nominal Voltage: 12 Volts • Rated Capacity: 12 AH (20 hour rate) • Length: 5.94" (151 mm) • Width: 3.90" (99mm) • Height: 3.78" (96mm) • Total Height 3.94" (1 00mm) Weight: 8.82 lbs (4.Okg) • Terminals: F1 -Faston Tab No. 187 U.L. Recognized Two Year Warranty ELECTRICAL SPECIFICATIONS: 20 hour rate (0.6A) 12AH Capacity 10 hour rate (1. 14A) 11AAH 77'F(25 -C) 5 hour rate (1.9A) 9.5AH 1 hour rate (7.2A) 7.2AH Internal Resistance, 20mO Fully Charged Battery (77'F) 104-F (40-C) 102% Capacity affected by 77-F (25-C) 100% Temperature (20 hour rate) 32-F (0-C) 85% 5-F (-15'C) 65% Cycle: Initial Charging Current less than 3.6A Charge Constant Voltage Voltage 14AV - 15.OV at 77*F(25'C) I Standby: Voltage 13.5V - 13.8V at 77*F(25'C) Dimensions(mm) Page I of 2 http://www.elkproducts.com/products/elk- I 2120.htm 11/12/04 ELK- 12120 Sealed Lead Acid Battery 10 V DiSebarge characteristics (20-c' WT) DiscbaW Time 14, 3 2 I wk Ln5cnarge 4.�namcftmsucs 1pl� To order the ELK -12120 Call your nearest distributor or ELK at 1-800-797-9355 for more information [ Home ] ELK Products, Inc. P.O. Box 100, Hildebran, N.C. 28637 USA (828) 397-4200 Copyright@2004 All rights reserved Terms and Conditions Page 2 ef,2 http://www.elkproducts.com/products/elk- I 2120.htm 11/12/04