3601 Orlando Dr - BC08-001628 (KFC) (INTERIOR RENOVATION) (A)A. ALL WORK SHALL CONFORM TO THE 2004 EDITION OF THE FLORIDA BUILDING CODE (2006 REV), AND ALL OTHER APPLICABLE CODES, STANDARDS, AND REGULATIONS OF THE CITY OF SANFORD, FLORIDA. B. IT IS INTENDED THAT A COMPLETE OCCUPIABLE BUILDING PROJECT IS PROVIDED. C. THE GENERAL CONDITIONS OF THE CONTRACT FOR CONSTRUCTION (A,I.A. A201 LATEST EDITION) ARE A PART OF THESE CONTRACT DOCUMENTS. A COPY IS ON FILE AT THE ARCHITECT'S OFFICE. D. DRAWINGS ARE BASED ON A SURVEY, DATED 11-28-2007 PREPARED BY TINKLEPAIJGH SURVEYING SERVICES, INC. AND IS INCLUDED IN THESE DOCUMENTS. E. THIS BUILDING HAS BEEN DESIGNED IN ACCORDANCE WITH THE RECOMMENDATIONS OF A GEOTECHNICAL INVESTIGATION BY PSI. THE REPORT IS PART OF THESE CONTRACT DOCUMENTS, AND THE CONTRACTOR IS RESPONSIBLE FOR CARRYING OUT ITS RECOMMENDATIONS, THOUGH SOME MAY NOT BE SPECIFICALLY DETAILED ON THE PLANS. F. DO NOT SCALE THESE DRAWINGS. VERIFY ALL DIMENSIONS AND CONDITIONS IN THE FIELD. ANY DISCREPANCIES IN THESE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO STARTING WORK, G. ALL PROPOSED SUBSTITUTIONS SHALL BE APPROVED BY THE YUM BRANDS CONSTRUCTION MANAGER, IN WRITING, PRIOR TO INSTALLATION. H. RETAIN THE PROJECT GEOTECHNICAL ENGINEER TO PROVIDE OBSERVATION AND TESTING SERVICES DURING THE GRADING (INCLUDING UTILITY TRENCHES) AND FOUNDATION PHASE OF CONSTRUCTION AS RECOMMENDED IN THE GEOTECHNICAL REPORT. ALL TESTING AND INSPECTION REPORTS, INCLUDING FINAL SUMMATION LETTER, SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND OWNER, G.C. SHALL CERTIFY PAD ELEVATION PRIOR TO START OF FOUNDATION WORK, I. SUBMIT PAY FEES AND OBTAIN ALL PERMITS ASSOCIATED WITH THE PROJECT EXCEPT GENERAL BUILDING PERMIT. THIS INCLUDES, BUT IS NOT LIMITED TO ELECTRICAL, MECHANICAL, PLUMBING, FIRE SPRINKLER, HOOD ANSUL, OR OTHER RELATED FIRE PERMITS, ENCROACHMENT PERMIT, ETC, YUM BRANDS WILL PAY FOR "CONNECTION FEES" ASSOCIATED WITH UTILITY PERMITS. PAY FOR TEMPORARY FACILITIES FEES AS REQUIRED TO COMPLETE THE WORK IN A TIMELY MANNER. J. PROVIDE EACH SUBCONTRACTOR WITH A COMPLETE AGENCY -PERMITTED DRAWING SETAT TIME OF CONSTRUCTION. K. ALL ABBREVIATIONS INCLUDED FOLLOW INDUSTRY STANDARDS. CONTACT ARCHITECT IF ANY ABBREVIATIONS ARE NOT CLEAR, L GC SHALL SUPPLY AND INSTALL ALL ASPECTS OF THE PROJECT DESCRIBED IN THIS DRAWING SET UNLESS OTHERWISE NOTED. SEE SCOPE OF WORK FOR EXCEPTIONS. M. GRAPHIC AND WRITTEN INFORMATION ON DRAWINGS SHALL BE COORDINATED WITH ALL TRADES PRIOR TO INSTALLATION. PROJECT GENERAL NOTES NAME ROOM NAME .I SHEET NUMBER 44( :AX. >2 �-- ELEVATION NUMBER 3 8' 4" CEILING HEIGHT BLDG. SECTION LETTER X AX.X BLDG. SECTION SHEET XELEV. LETTER AX' ELEV. SHEET ODOOR NUMBER O WINDOW NUMBER / DECOR ITEM NUMBER ❑X EXTERIOR WALL FINISH NUMBER KEY NOTE X-000 EQUIPMENT NUMBER XX ROOM FINISH NUMBER �-- DETAIL NUMBER 425 d� X X DIRECTION OF DETAIL �( INTERIOR ELEVATION DESIGNATION DETAIL SHEET 15500 NEW BARN ROAD SUITE 106 A REVISION NUMBER ID SHEAR WALL TYPE (STRUCTURAL) r0=0 BLDG. HEIGHT ELEV REFERENCE POINT XXX 000 EQUIPMENT/ FIXTURE NUMBER (M.E.P,) REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL SHEETS FOR SPECIFIC SYMBOLS GENERAL DRAWING SYMBOLS LEGAL JURISDICTION: CITY OF SANFORD BUILDING CODE: FBC 2004 (2006 REV), NEC,2002'�60� BUILDING AREA: BUILDING 2,517 S,F. (PLUS 298 S.F. WALK-IN COOLER/FREEZER = 2815 S.F, TOTAL) SEATING: 60 TYPE CONSTRIJCTIO',F(<I;D a# PHONE LINES: 25 PAIR CABLE IN 2" CONDUIT .+n�OTtlyp �T�' �rL 4 +Prt�, :<"nA'ns�w4xa iy, �C,E ,IC CASE; �N 80 /1[?S / 3 FHP,SE/(120 �08aVOL' .���� PROJECT SUMMARY OWNER 425 d� KFC US PROPERTIES, INC, CKE GROUP, INC. a4q 417 4� 15500 NEW BARN ROAD SUITE 106 Orlando, FL 32822 o� Operating Brand: KFC Contact: JUAN CARCACHE o Phone: (954) 805-7089 CONSTRUCTION MANAGER q JMERI CgNA t2< �, YUM BRANDS, INC. CKE GROUP, INC, 6200 Lee Vista Blvd, 15500 NEW BARN ROAD SUITE '106 Orlando, FL 32822 PROJECT Contact: JOHN MCCARTHY Contact: EDUARDO CARCACHE LOCATION Phone: (305) 558-4124 CIVIL ENGINEER ggULEVERD CKE GROUP, INC. TROPIC-KOOL ENGINEERING;, p� `,�.� 1332 DONEGAN ROAD MIAMI LAKES , FLORIDA 33014 V� Contact: EDUARDO CARCACHE Contact: BILL JOHNSON LOCATION MAP N Phone: (727) 581-2824 GEOTECHNICAL ENGINEER NOT TO SCALE Pr6fessional Sewice Industries, Inc. (PSI) BARTL ETT LANDSCAPE, INC. 1748 33rd Street 144117 STIRRUP LANE VICINITY MAP LEGAL JURISDICTION: CITY OF SANFORD BUILDING CODE: FBC 2004 (2006 REV), NEC,2002'�60� BUILDING AREA: BUILDING 2,517 S,F. (PLUS 298 S.F. WALK-IN COOLER/FREEZER = 2815 S.F, TOTAL) SEATING: 60 TYPE CONSTRIJCTIO',F(<I;D a# PHONE LINES: 25 PAIR CABLE IN 2" CONDUIT .+n�OTtlyp �T�' �rL 4 +Prt�, :<"nA'ns�w4xa iy, �C,E ,IC CASE; �N 80 /1[?S / 3 FHP,SE/(120 �08aVOL' .���� PROJECT SUMMARY OWNER ARCHITECT KFC US PROPERTIES, INC, CKE GROUP, INC. 6200 Lee Vista Blvd, 15500 NEW BARN ROAD SUITE 106 Orlando, FL 32822 MIAMI LAKES, FLORIDA 33014 Operating Brand: KFC Contact: JUAN CARCACHE Phone: (407) 330-5609 Phone: (954) 805-7089 CONSTRUCTION MANAGER STRUCTURAL CONSULTANT YUM BRANDS, INC. CKE GROUP, INC, 6200 Lee Vista Blvd, 15500 NEW BARN ROAD SUITE '106 Orlando, FL 32822 MIAMI LAKES, FLORIDA 33014 Contact: JOHN MCCARTHY Contact: EDUARDO CARCACHE Phone: (407) 864-8260 Phone: (305) 558-4124 CIVIL ENGINEER MECH. / ELEC. ENGINEER CKE GROUP, INC. TROPIC-KOOL ENGINEERING;, 15500 NEW BARN ROAD SUITE 106 1332 DONEGAN ROAD MIAMI LAKES , FLORIDA 33014 LARGO, FLORIDA 33771 Contact: EDUARDO CARCACHE Contact: BILL JOHNSON Phone: (305) 558-4124 Phone: (727) 581-2824 GEOTECHNICAL ENGINEER LANDSCAPE ARCHITECT Pr6fessional Sewice Industries, Inc. (PSI) BARTL ETT LANDSCAPE, INC. 1748 33rd Street 144117 STIRRUP LANE Orlando, FL 32839 WELLINGTON, FLORIDA 33414 Phone: (407) 304-5560 Contact: RICK BARTLETT ` Phone: (561) 795-0443 PROJECT DIRECTORY vlreushlea . N S`&9- Ill VIN IQ CITY OF SANFORD UTILITY DEPARTMENT BELLSOUTH 300 SANFORD UTILITY DEPARTMENT 501 WEST 9th STREET SANFORD, FLORIDA 32771 SAN FORD , FLORIDA 32771 Contact: RICHARD, BLAKE Contact: COMMERCIALS ALES Phone: (407) 330-5609 Phone: (407) 323-4720 WATER CITY OF SANFORD UTILITY DEPARTMENT 300 SANFORD UTILITY DEPARTMENT SANFORD, FLORIDA 32771 Contact: RICHARD. BLAKE Phone: (407) 330-5609 GAS FLORIDA PUBLIC UTILITIES STRUCTURAL P,O.BOX 530969 DeBARY , FLORIDA 327510969 Phone: (386) 668-2600 ELECTRIC FLORIDA POWER & LIGHT Contact: JOHN TRINIDAD Phone: (407) 328-1902 UTILITY CONTACTS PL r CKE pm%q6au rw DA"51neering-architecture planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 ppb SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 ...r- .�.A - - - „- - .. - a,• .� a e.- v / t 9111 ANY ERROR OR OMISSION IN PLAN REVIEW SHALL NOT BE >TRUCED TO GRANT APPRO VAL OF VIOLATION OF ANY ADOPTED :ENT BUILDING CODES OR [CIPAL CODES OF THIS DICTION 0 0 0 0 0 0 ,L CONTRACT DATE: A B C G E F. G FI TITLE/SITE DRAWING DATE: 3-11-2008 T1.0 TITLE SHEET STRUCTURAL S1.0 FOUNDATION PLAN S2.0 NOT USED 53.0 ROOF FRAMING PLAN S4.0 STRUCTURAL DETAILS (FOUNDATION) S4.1 STRUCTURAL DETAILS (ROOF) S4,2 STRUCTURAL DETAILS (ROOF) 35.0 STRUCTURAL ELEVATIONS ARCHITECTURAL A1.0 FLOOR PLAN A1.1 DOOR &WINDOW ELEVATIONS & SCHEDULES A2.0 EQUIPMENT AND SEATING PLAN A2.1 EQUIPMENT SCHEDULE A3.0 ROOF PLAN A4.0 EXTERIOR ELEVATIONS A4.1 EXTERIOR ELEVATIONS A5,0 WALL SECTIONS A5.1 WALL SECTIONS - TOWER SECTIONS A5.2 WALL SECTIONS - TOWER SECTIONS A6,0 CONSTRUCTION DETAILS - ROOF A6.1 CONSTRUCTION DETAILS - DOOR & WINDOW A6,2 CONSTRUCTION DETAILS -WALL A6.3 CONSTRUCTION DETAILS - INTERIOR FINISH A7.0 FLOOR FINISH PLAN A7,1 REFLECTED CEILING PLAN A7.2 FINISH SCHEDULE A8.0 INTERIOR ELEVATIONS - DINING ROOM A8,1 INTERIOR ELEVATIONS, ENLARGED RESTROOM & OFFICE PLAN A6.2 INTERIOR ELEVATIONS - KITCHEN A8,3 INTERIOR ELEVATIONS - KITCHEN ACCESSIBILITY ADA1.0 ACCESSIBILITY REQUIREMENTS ADA1.1 ACCESSIBILITY REQUIREMENTS MECHANICAL M1.0 MECHANICAL SCHEDULES AND NOTES CODE COMPLIANCE TO BE M2.0 DUCT AND DIFFUSER PLAN FIELD VERIFIED BY CITY M3.0 HOOD DRAWINGS - PLANS AND SECTIONS BUILDING INSPECTOR M3,1 HOOD FIRE SUPPRESSION DETAILS . ` NOT] M4,0 MECHANICAL &HOOD DETAILS THIS PLUMBING CON; P1,0 PLUMBING SCHEDULES AND NOTES CODE COMPLIANCE TO BE ANY P2.0 WASTE AND VENT PLAN FIELD VERIFIED BY CITY CURI P3.0 WATER AND GAS PLAN BUILDING INSPECTOR MUN P4,0 PLUMBING ROUGH -IN PLAN JURIk, 1`5,0 RISER DIAGRAMS P6,0 PLUMBING DETAILS ELECTRICAL E1.0 SITE ELECTRICAL PLAN E2.0 RISER DIAGRAM AND LEGEND E2.1 PANEL SCHEDULES AND LOAD SUMMARY CODE COMPLIANCE TO BE E3,0 POWER FLOOR PLAN FIELD VERIFIED BY CITY E3.1 ENLARGED POWER PLAN AND DETAILS BUILDING INSPECTOR E3,2 POWER ROOF PLAN E4,0 LIGHTING PLAN & SCHEDULE E5.0 COMMUNICATIONS PLAN E6,0 ELECTRICAL DETAILS SCOPE OF WORK SEE SPECIFICATIONS SPECIFICATIONS IN BOOK FORMAT e j Diva. PL r CKE pm%q6au rw DA"51neering-architecture planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 ppb SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 ...r- .�.A - - - „- - .. - a,• .� a e.- v / t 9111 ANY ERROR OR OMISSION IN PLAN REVIEW SHALL NOT BE >TRUCED TO GRANT APPRO VAL OF VIOLATION OF ANY ADOPTED :ENT BUILDING CODES OR [CIPAL CODES OF THIS DICTION 0 0 0 0 0 0 ,L CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE .` SANFORD, FLORIDA K -y07 (Cmu) TITLE SHEET SHEET INDEX I PLOT DATE: 2008 A 11 6" 70'-B" (FACE OF MASONRY TO FACE OF MASONRY) 2' 0' h' 0" 171-61 10'-0" M.O. M.O. - - _F_ - - - - SLAB TO BE 6" WIDER THAN VV,I.C. ON EXPOSED SIDES v VERTICAL TIES REMARKS AARK SIZE REINFORCENG 7 REBAR MARK SIZE REMARKS CROSSBAR PROTECTION. SEE SPECIFICATIONS SECTION 02362. (WOOD) 2. ALL TIMBER WOOD IN CONTACT WITH CONCRETE SHALL BEPRESSURE TREATED 3. SEE SITE PLAN FOR LOCATION ON WALKS, CURB, ACCESSIBLE c 1 C-1 �� 8" x '12" 4 #5 VERT #3 cco 8;; c/c TIE COLUMN TO BE PO V',(/ MASONRY IN PLA J I :: .. ;,;i:, EI;: � li:l �;: � : i ::t .; ; .. ,I,..l , ., li`II i Ili ( :• .::I . :E..I E: N!F 1 WF 'I V+IF-'1 RAMPS AND ALL OTHER MISCELLANEOUS SITE WORK W REINFORCED G ;.............._.., 74 0 WF-2 12" x 32" 3#5 CONT. #3 @ 36" ac. r �� _.... 14 MASONRY WALL 6 TYP. 4. FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OF MINIMUM 1,- CON CRE fE S TF3E TfH = :3,000 PSI. 2.- LAP ALL VERTICAL R IF.: 36 BAR 0 (U.O.N,) F-1 4'-0" x 4'-0" x 12" 6#5 EACH WAY FRONT PIERS S4.0 RTI FS S4.0 5. TOP OF FOOTINGS ARE SHOWN AS BEING 1' 4" MIN. BELOW GRADE, F-2 3'-0" x .3 0 x 12 405 EACH WAY 4.- NO SPLICE ALLOWED AT 1 RMEDIATE BM. OR TB„ VERIFY SOILS STRENGTH, FROST PROTECTION AND OTHER LOCAL 5.- ALL CONCRETE TIE COLUMNS S L BE'OURED IN DIRECT OQi CT w,BLOCKING BEARING'iVALL. CODE REQUIREMENTS PRIOR TO POURING CONCRETE AT 32' Cie (TYP _ _ -. _ FD ; ...... ._ F F-3 FF -3 F-2 2#5 CONT. - 6. COMPACTION TEST, AS REQUIRED BY THE SOILS REPORT AND YUM BRANDS, CONCRETE MASONRY: ALL CONCRETE MASONRY CONSTRUCTION SHALL ONFOR 0 THE REOUIRENIENTS OF SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, CD 5 L "SPECIFICATIONS FOR THE DESIGN AND CONSTRUCT F LOAD BEARING CONCRETE MASONRY: PROVIDE BUILDING DEPARTMENT WITH TEST RESULTS,. OF THE NATIONAL CONCRETE MASONRY AS50CIATI A ACI 530-88 & ACI 530,1-88. �FD 7, CONCRETE BLOCK SHALL BE NORMAL WEIGHT 6.--'.; FD l 1, AT EXTERIOR DOOR OPENINGS: 5,- ALLOWABLE SOIL BEARING; ` :' j FD HAVE AN ULTIMATE NET COMPRESSIVE STR TH OF 2,000 P51 IMIJNI TO GIVE A MINIMUM �"' i r.:. :..�C � :... � �� PROVIDE HORIZONTAL JOINT REINFCEMENT EVERY OTHER COURSE (1 /c)-DUPOWALL-9 GA. -LADDER TYPE, AS INDICATED ON FOUNDATION PLAN FOR 2,500 P.S.F. PROVIDE CONTROL JOINT CENTERED ON WALLn SOIL BEARING PRESSURE, VERIFY 9. CONCRETE IS DESIGNED FOR P = 3000 PSI MINIMUM COMPRESSIVE STRENGTH, POURED CONCRETE SHALL MORTAR SHALL BE ASTM C-270. RTLAND CEIV:ENT/LIME TYPE "S" FRESHLY P PARED AND UNIFORMLY MIXED WITH MINIMUM CUNIR ESSIVE STRENGTH OF 18,00 PSI @28 DAYS- FACE v . LL OF BED JOINTS TO 2- MONOLITHIC SLAB EDGE PER DETAIL SOIL BEARING CAPACITY BE EQUAL TO f' = 3000 P.S.I, MINIMUM COMPRESSIVE STRENGTH. SIM. IS TYPICAL UNLESS NOTED OTHERWISE. BEFORE PLACING FOOTINGS. 3.- TOP FOOTING TO BE VA" BELOW TOP 7,- VERIFY EXACT SLAB DIMENSIONS FLOOR SLAB, UNLESS NOTED OTHERWISE, 1N1 FREEZER MANUFACTURER 4.- CONCRETE BLOCK COURSING STARTS AT TOP PRIOR TO CONSTRUCTION 10. REINFORCING STEEL TO LAP WHERE SPLICED 48 DIA. MINIMUM LAP 24". 11. ALL INTERIOR SILL PLATES FOR WOOD STUD WALLS SHALL BE FASTENED TO SLAB WITH 0.145 DIA. POKIER DRIVEN FASTENERS WITH (2) 7/8" WASHERS FILL ALL CELLS WTT ONCRETE GROUT CONTAINING REINFORCING STEEL. (NEXT TO 0 JINGS) GROI-IT USED IN C .i CRETE BLOCKS SHALL HAVEA MNIMUM COMPRESSIVE STRENGTH OF2,500 PSI @ 28 S• GROUT MUSTH' !E A SLUMP BEPIVEEN 3" MIN. AND 12' MAX. _......." B-OTTO� F CELLS TO BE FILLED. ALL GROUT SHALL BE PUDDLED WITH GROUT STICK IMMEDIATRLY AFTER POURING. 5'-0" 5'-0" ' EYE FOOTING SCHEDULE E GENERAL NOTES 0o 00 S 4.0 i FD TERMITE PROTECTION - ALL SOIL AND FILL UNDER FLOORS AND/OR"WITHIN OR UNDER BUILDING SHALL HAVE HD '� r.") HD PRECONSTRUCTION SOIL TREATMENT FOR PROTECTION AGAINST TERMITES. THE STANDARDS OF NATIONAL PEST CONTROL ASSOCIATION SHALL BE DEEMED AS \-CD 8 co �, 14 - : S4 0 APPROVED IN RESPECT TO PRECONSTRUCTION SOIL TREATMENT FOR PROTECTION _ 54.0 i m4 AT 12'cic cin TYP. AGAINST TERMITES. CERTIFICATE OF COMPLIANCE SHALL BE ISSUED TO THE BUILDING DEPARTMENT BY LICENSED PEST CONTROL AGENCY THAT CONTAINS THE FOLLOWING STATEMENT "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES. TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS �`` �_� 11 ti j % 5-0:1 5-0" WITH 906 HOOK O (TYP.) AT PERIMETER - 0„ o CC) F 50 -'I it r;-3 FD j /: ; r I �` ESTABLISHED BY THE FLORIDA DEPARTMENT OF AGRICULTURE AND CONSUMER SERVICES." i `> FD + „ 22 \^� C-) . ' F, Ii SEE FOOTING 4 CONCRETE SLAB REINFORCED TYP, 4 0 B„ 1 l SCHEDULE NOTE #1 i WITH 6" x 6" x W1 A W.W.F. 5'-011 � 0, �4 O - OVER 6 MIL VAPOR BARRIER ' O LU OVER WELL COMPACTED FILL �r ELL �FS �! NOTE: DESIGN SOIL BEARING CAPACITY FD SEE FOOTING 10 - = 2500 P.S.F. - REFER TOQ SOILS REPORT ; 4 SCHEDULE NOTE #1 = 1 SIM. - 8" REINFORCED MASONRY WALL WITH #6 VERTICAL SEE FOOTING SCHEDULE NOTE #1 i ` •.. 2 SEE FOOTING SCHEQULE NOTE #1 AT 32" c/c (TYP.) 1 1 �, 18 31 M. 2 `-:-J- 18 FD 1 J 1 it H D =- J 1� 54.0 S4,U S4.0 TYP. S4 0 54,0 TYP. Ns -S4.0 �' 54.0 J � I F 2 r V�/F-1 WF -1 1/UF-1 1 L- . -• - :: ' _a • :: :: ,.:.I€�;E;� : :; I 11 j f ! E � .; f I E Ijj l ?1 ;: E E 1: i ': I f:; - _ r- 6,_.10y2, M.O. M.O M.O. 28'-10" M.O. 2'-4" I VA" 70'-B" (FACE OF MASONRY TO FACE OF MASONRY) 10'-0" 1_> I 11 I 10 I 9 1 8 1 7 VERTICAL TIES REMARKS AARK SIZE REINFORCENG 1. CONTRACTOR TO TREAT SOIL UNDER SLAB WITH PROPER TERMITE REBAR MARK SIZE REMARKS CROSSBAR PROTECTION. SEE SPECIFICATIONS SECTION 02362. (WOOD) 2. ALL TIMBER WOOD IN CONTACT WITH CONCRETE SHALL BEPRESSURE TREATED 3. SEE SITE PLAN FOR LOCATION ON WALKS, CURB, ACCESSIBLE c 1 C-1 �� 8" x '12" 4 #5 VERT #3 cco 8;; c/c TIE COLUMN TO BE PO V',(/ MASONRY IN PLA J WEE 12" x 24' 3#5 CONT. 03 @ 36" ac. RAMPS AND ALL OTHER MISCELLANEOUS SITE WORK WF-2 12" x 32" 3#5 CONT. #3 @ 36" ac. 4. FOOTINGS SHALL BEAR ON UNDISTURBED SOIL OF MINIMUM 1,- CON CRE fE S TF3E TfH = :3,000 PSI. 2.- LAP ALL VERTICAL R IF.: 36 BAR 0 (U.O.N,) F-1 4'-0" x 4'-0" x 12" 6#5 EACH WAY FRONT PIERS 2,500 PSF BEARING CAPACITY. 3 HOOK COL. VERTICAL S AT FOOTING &TOP BEAM 5. TOP OF FOOTINGS ARE SHOWN AS BEING 1' 4" MIN. BELOW GRADE, F-2 3'-0" x .3 0 x 12 405 EACH WAY 4.- NO SPLICE ALLOWED AT 1 RMEDIATE BM. OR TB„ VERIFY SOILS STRENGTH, FROST PROTECTION AND OTHER LOCAL 5.- ALL CONCRETE TIE COLUMNS S L BE'OURED IN DIRECT OQi CT w,BLOCKING BEARING'iVALL. CODE REQUIREMENTS PRIOR TO POURING CONCRETE 6,- FOOTING DOWELS, SAME SIZE & NU ER OF COLUMN ABOV , P=36 B,AR DIA. 8' (U.0•�'.) F-3 16" x 16" 2#5 CONT. - 6. COMPACTION TEST, AS REQUIRED BY THE SOILS REPORT AND YUM BRANDS, CONCRETE MASONRY: ALL CONCRETE MASONRY CONSTRUCTION SHALL ONFOR 0 THE REOUIRENIENTS OF SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR, "SPECIFICATIONS FOR THE DESIGN AND CONSTRUCT F LOAD BEARING CONCRETE MASONRY: PROVIDE BUILDING DEPARTMENT WITH TEST RESULTS,. OF THE NATIONAL CONCRETE MASONRY AS50CIATI A ACI 530-88 & ACI 530,1-88. 7, CONCRETE BLOCK SHALL BE NORMAL WEIGHT CONCRETE MASONRY UNITS SHALL CONFORd�I ASTM C-90. qLL CONCRETE BUCKS SHALL 1, AT EXTERIOR DOOR OPENINGS: 5,- ALLOWABLE SOIL BEARING; UNITS A5 PER ASTM C-90 SPECIFICATIONS. HAVE AN ULTIMATE NET COMPRESSIVE STR TH OF 2,000 P51 IMIJNI TO GIVE A MINIMUM PROVIDE #4 BARS A'T '12" ON CENTER PRESSURE 2,500 P.S.I. COMPRESSIVE STRENGITH OF MASONRY SEMBIAGE (Nn) OF `,500 1 UNLESS NOTED OTHERWISE, x 6-0 LONG, (10 AT COOLER) WITH e" PROJECTION 6.- ALL FOOTINGS ARE DESIGNED 8, REINFORCING STEEL f0 BE INTERMEDIATE GRADE DEFORMED BARS AS PER ASTM A615 (GRADE 60) 60,000 P.S.I. MIN. YIELD. PROVIDE HORIZONTAL JOINT REINFCEMENT EVERY OTHER COURSE (1 /c)-DUPOWALL-9 GA. -LADDER TYPE, AS INDICATED ON FOUNDATION PLAN FOR 2,500 P.S.F. PROVIDE CONTROL JOINT CENTERED ON WALLn SOIL BEARING PRESSURE, VERIFY 9. CONCRETE IS DESIGNED FOR P = 3000 PSI MINIMUM COMPRESSIVE STRENGTH, POURED CONCRETE SHALL MORTAR SHALL BE ASTM C-270. RTLAND CEIV:ENT/LIME TYPE "S" FRESHLY P PARED AND UNIFORMLY MIXED WITH MINIMUM CUNIR ESSIVE STRENGTH OF 18,00 PSI @28 DAYS- FACE v . LL OF BED JOINTS TO 2- MONOLITHIC SLAB EDGE PER DETAIL SOIL BEARING CAPACITY BE EQUAL TO f' = 3000 P.S.I, MINIMUM COMPRESSIVE STRENGTH. BE FULLY MORTARED,W ` SHALL BE FULLY MORTARED WERE AAD,jACENT CELLS A, TO BE GROUTED/FILLED IS TYPICAL UNLESS NOTED OTHERWISE. BEFORE PLACING FOOTINGS. 3.- TOP FOOTING TO BE VA" BELOW TOP 7,- VERIFY EXACT SLAB DIMENSIONS FLOOR SLAB, UNLESS NOTED OTHERWISE, 1N1 FREEZER MANUFACTURER 4.- CONCRETE BLOCK COURSING STARTS AT TOP PRIOR TO CONSTRUCTION 10. REINFORCING STEEL TO LAP WHERE SPLICED 48 DIA. MINIMUM LAP 24". 11. ALL INTERIOR SILL PLATES FOR WOOD STUD WALLS SHALL BE FASTENED TO SLAB WITH 0.145 DIA. POKIER DRIVEN FASTENERS WITH (2) 7/8" WASHERS FILL ALL CELLS WTT ONCRETE GROUT CONTAINING REINFORCING STEEL. (NEXT TO 0 JINGS) GROI-IT USED IN C .i CRETE BLOCKS SHALL HAVEA MNIMUM COMPRESSIVE STRENGTH OF2,500 PSI @ 28 S• GROUT MUSTH' !E A SLUMP BEPIVEEN 3" MIN. AND 12' MAX. MAXIMU FIGHT OF GROUT POUR SHALL BE ,I'-0' UNLESS CLEAN OUT OPENINGS ARE PROVIDED THE B-OTTO� F CELLS TO BE FILLED. ALL GROUT SHALL BE PUDDLED WITH GROUT STICK IMMEDIATRLY AFTER POURING. OF FOOTING WITH COURSE #1 COLUMN SCHEDULE FOOTING SCHEDULE E GENERAL NOTES 3'-10" I'-4" N1,0. 6-2" 5 1 4 SUITABLE FILL MATERIAL AND THE COMPACTION OF FILL SOILS 5 ALL FILL MATERIALS SHOULD BE FREE OF ORGANIC MATERIALS, SUCH AS ROOTS AND VEGETATION. AS A GENERAL GUIDE TO AID ,THE CONTRACTOR, WE RECOMMEND USING FILL WITH 3 TO 10 PERCENT BY DRY WEIGHT OF MATERIAL PASSING THE 19.5, STANDARD No. 200 SIEVE SIZE ALL STRUCTURAL FILL SHOULD BE PLACED IN LEVEL FIFTS NOT 'TO EXCEED 12 INCHES IN UNCOMPACTED THICKNESS,EACH LIFT SHOULD BE COMPACTED TO AT LEAS F 95 PERCENT OF THE MODIFIED PROCTOR (A,aTM D--1557) MAXIMUM DRY DENSfTY VALUE. THE FILLING AND COMPACTION OPERATIONS SHOULD CONTINUE IN LIFTS UNTIL THE DESIRED ELEVATION (S), IS ACHIEVED, IF HAND-HELD COMPACTION EQUIPMENT IS USED, THE LIFT THICKNESS SHOULD BE REDUCED -TO 6 INCHES. FOUNDATION SUPPORT BY SPREAD FOOTINGS AND FOUNDATfON COMPACTION CRITERIA EXCAVATE -THE FOUNDATIONS TO THE PROPOSED BOTTOM OF FOOTING ELEVATIONS AND, THEREAFTER, VERIFY THE IN-PLACE COMPACTION FOR A DEPTH OF ONE FOOT BELOW THE FOOTING BOTTOMS, IF NECESSARY. COMPACT THE BOTTOM OF THE EXCAVATIONS TO ACHIEVE A MINIMUM DRY DENSITY EQUIVALENT TO 95 PERCENT OF -THE MODIFIED PROCTOR MAXIMUM DRY DENSITY (ASTM D-1557) FOR A DEPTH OF 2 FEET BELOW THE FOOTING BOTTOMS. BASED ON THE EXISTING SOIL CONDITIONS AND, ASSUMING THE ABOVE OUTLINED PHOOF-ROLLING AND COMPACTION CRITERIA IS IMPLEMENTED, AN ALLOWABLE SOIL BEARING PRESSURE OF 2,500 POUNDS PER SQUARE FOOT (PSF) MAY BE USED IN THE FOUNDATION DESIGN. REFER TO SOILS REPORT BY: P51, INC, TELE.: (407) 304-5560 3 INCORPORATED engineering �r�r terJ tu r P idnninJ 15500 NEW BARN ROAD SUITE '106 MIAMI LAKES, FLORIDA 33014 PHONE: X305) 558-4124 E FAX: (305)826-0619 EB#0004432 0� SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 D JACK D. RAUDENBUSH ARCHITECT -AR 2808 C EOG�EU,.UvTH 6' t 6 Q VAPO�a'��E��� Q ,VER W�LI�GU,pQBECTEQ:;�ICL Q CD A CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 2 1 STORE NUMBER: W750279 DRAWING`; DATE: 3-1'I-2008 FOUNDATION PLAN 1/4"=1'-0" A KFC `�! J SLAB SHALL BE PITCHED 112" FOR 5'-0" DIA. AT ALL FLOOR DRAINS U.O.N. 3601 S ORLANDO DRIVE REFER TO PLUMBING DRAWINGS FOR LOCATIONS, SANFORD , FLORIDA D PROVIDE HUB DRAIN (HD) UNLESS REQUIRED BY LOCAL CODE TO HAVE FLOOR SINK (FS) CJ INDICATES INSIDE SURFACE OF FOOTING. SEE SHEET S4.0 4 FLOOR DRAIN FOR MOP SINK. `�5 1 #6 IN CONCRETE FILLED CELL AT EACH SIDE OF MASONRY OPENING BAR TO BE CONTINUOUS FROM FOOTING TO BEAN] TERMINATING WITH K -y07 STANDARD HOOK, ALL SPLICES TO BE MIN. 48" LAP (TYPICAL) SEE 7%34.0 �J COORDINATE PAD SIZE WITH WALK-IN BOX MANUFACTURERS SHOP DRAWINGS. 7 THICKEN PIER, MATCH DEPTH OF BLDG, FOOTING, PROVIDE #5 BOT. C PERIMETER OF PIER (MAINTAIN MIN, 3" COVER), 8" FOUNDATION RECESS FOR CMU, TYP. FOUNDATION 30"x3U" FOOTING av/ (3) #5 REBAR EW, BOT. PLAN 10 ELECTRICAL STUBS THRU SLAB. SEE ELECT. DRAWINGS FOR LOCATIONS. 1/2" WATER LINE THRID FLOOR, SEE PLUMBING DRAWINGS FOR LOCATION. PROVIDE PVC SLEEVE THRU SLAB. Im 1114 AN KEY NOTES N.T.S. PLOT DATE: 2006 1. SHADED AREAS INDICATE DECK IS TO BE OMITTED AT DUCT AND EQUIPMENT PENETRATIONS. 2. TRUSSES ARE DIMENSIONED ON CENTER. DOUBLED TRUSSES UNDER ROOFTOP UNITS AND AT THE CUPOLA PLATFORM ARE DIMENSIONED TO THE CENTER OF THE COMBINED 3' WIDTH. 3. ROOF DECKING & NAILING: A. AT BLOCKED DIAPHRAM (23 FT. MIN, FROM EACH END -HATCHED AREA) 19/32 APA RATED PLYWOOD, EXP. 1, V//10d NAILS AT 21/2"r� c ALONG PERIMETER, 4" ALONG PANEL EDGES AND 6" o.c. AT INTERMEDIATE SUPPORTS. B. ELSEWHERE_ 10/32 APA RATED PLYWOOD, EXP, 1, W/1Od NAILS AT 2 '1/2"ac. ALONG PERIMETER, 4" ALONG PANEL EDGES AND 6" c.c. AT INTERMEDIATE SUPPORTS, 4. CEILING HUNG SHELVING SHOWN ON SHEET EQI REQUIRES SUPPORTAT TRUSS. SEE CEILING HUNG SHELF DETAIL ON WALL SECTION SHEET 5. ALL DIMENSIONS SHOWN ON ROOF PLAN ARE FOR ROUGH OPENING ROOF FRAMING NOTES A I rAINtL tUutS ANU T c/c A I IN I tHIUH �31JF IJUH 113 & 2 1/2" AT PERIMETER WALLS - CROSS HATCHED AREA =18 FT. MIN. II II Il II II II II II II 11 I 11 11 11 II I II �c> 3 c 3E+" 3L 3E"" 3 rS MARK 10-28-2007 BUILDING TYPE: K -y07 STIRRUPS REMARKS SITE NUMBER: DEPTH BOTTOM TDP DRAWING DATE: ELEV. PROVIDE 2 #5 CORNER BARS 3'-0" BB -1 8�� 16" 12' 0" -1 #7 1 #7 LONG EA. LEG AT ALL CORNERS B-1 8" 24" 12'-0" 1 #7 '1 #7 PRECAST CONCRETE LINTEL - 81`24 RATED AT 2698 PLF "CASTCRETE" BY NOA 03-0605.05 B-2 8" 32" 12` 0" 1 #7 1 #7 PRECAST CONCRETE LINTEL 81`24 RATED AT 3685 PLF "CASTCRETE" BY NCA 03-0605.05 ' B-3 0 8" 8" 8' 4 1/�" PRECAST LINTEL PRECAST CONCRETE LINTEL RATED AT 1599 PLF - BY "CAti=)TCRETE" NOA 03-0605.05 (250 PLF ACTUAL LOAD) F8" ? PRECAST LINTEL PRECAST CONCRETE LINTEL RATED AT 1599 PLF - BY "CASTCRETE' NCA 03-0605.05 (250 PLF ACTUAL LOAD) 1,- BOTTOM BARS SHALL EXTEND 6" MIN. INTO ANY 4.- DROP BOTTOM OF TIE BEAM OR BEAM TO TOP COLUMN, ALL WAY INTO END COLUMNS, OF DOOR OR WINDOW HEAD AND ADD 2 #5 BOTTOM BARS. EXTEND DROP & REBARS 8" EA. SIDE OF 2.- TOP BARS SHALL EXTEND '1/4 SPAN INTO OPENING. ADJACENT BEAMS, HOOK AT END BEAMS, 5.- CAMBER BEAM FORMS 1/4" PER EA. 10 FT. SPAN. 3- TOP & BOTTOM BARS TO BE CONTINUOUS ONLY IF SO CALLED IN BEAM SCHEDULE BY A NOTE 6- PROVIDE 2 45 BEND BARS,, 3"' AT ALL CORNERS OR HEAVY DOT ( ), TOP BARS SPLICED AT OF TIE BEAMS OR BEAMS, cOF INA #3 TIES MIDDLE THIRD OF SPAN, BOTTOM BARS SPLICED @ 12" c/c (AT TB) WHERE 13END BARS OCCURS. BEAM SCHEDULE __F_C A I rtHIPVIL I tH WALL i - l; tU HA I (jHtU AHtA = 1 b t 1. MIM. D11II II II I! II II 11 II I! II !I II II II II li II r- I rcl- r- CV 1 r 1 `-- r I STARTING-, POINT OF TRUSS LAYOUT - REAR EDGE OF TRUSS. VERIFY NECESSITY OF DOUBLE TRUSSES V1IrH TRUSS mFR. DUE TO POINT LOADING, TYPICAL. SECOND TRUSS (IF REQ'D.) SHALL BE LOCATED ON THE FRONT SIDE OF I LLI JSTRATED TRUSS, COORDINATE BLOCKING WITH EXHAUST AND SUPPLY DUCT. SATELLITE DISH PIPE SUPPORT. SEE DETAIL 2/A6A C _5 CONT 2XII WD BRIDQ',ING ON TOP OF BOTTOM CHORD. ADJUST AS REOIRED FOR DUCT PLENUMS, MAX SPACING AT 4B" O.C, OR TIC?,HTER SPACING AS REQUIHED BY TRUSS DESIGN. SEE 12 & I6/S4.1 FOR CONFIGURATION, F� SIMPSON M TA 24 AT CORNER DBL TOP PLATE CEN TER S TRAP ON CORNER. (2) 2x6 BLOCKING W/ U26-2 HANGERS. TYP. ALL ROOF OPENINGS - SEE DETAIL 15/84.2 Q LOCATION OF HOODS, SEE HOOD DRAWINGS FOR HOOD ATTACHMENT DETAILS. 2x6 ,JOIST W/ U26 EACH END FOR LENGTH OF CONDENSER CURB. VERIFY LENGTH W/ M OPENING FOR SUPPLY FAN DUCT. C,11 EXHAUST DUCT OPENINGS SIZED FOR "DUCT WRAP", ADJUST ROUGH OPENINGS AS REQUIRED WHERE 'l -HR DUCT SHAFT CONSTRUCTION IS REQUIRED BY LOCAL CODE, REFER TO MECH, DWGS, 12 SEE DETAILS ON SHEET S4,3 FOR TOWER SUPPORT. .-13 NOT USED 114 HVAC HOOF OPENING FOR DUCT, VERIFY SIZE WITH HVAC MFR. & MECHANICAL DWGS, 2x4 BLOCKING FOR ROOF DRAIN AREA. SEE DETAIL 13/A6,0. 2X6 CEILING JOISTS C '16" O.C. @ 10' 4" A,F,F. SEE 1/A6,4, �_'I 7> 2x6 a 2'-0" O.C. W/ IJ -26 @ EA. ENE CD NOT USED (-19–) LOCATION OF STEAM HOOD (NOT SUSPENDED FROM TRUSSES). KEY NOTES ROOF PLAN 1r1 I'IJ° I A TRUSS TO WALL ANCHORAGE SCHEDULE REACTIONS NIAXIPJUIvI) MK UPLIFT CAPACITY STRAP UPLIFT = 3,117 LBS. NU-VUE INDUSTRIES NXHTA-16H L1 = '1,575 LBS. WITH DOUBLE NVHTA-20 STRAPS & L2 = 2,175 LBS, INTO STRAP & 6-10d x 1 112" NAILS INTO SEAT PER NOA 04-0510.03 O 6224 LBS. (2 PLY) 6224 LBS. (3 PLY OR GREATER) 4945 LBS. HORIZONTAL (L-2) UPLIFT = 1,117 LBS. L = 520 LBS. L2 = 630 LBS. SEE DETAIL 2/S4.2 NU -VIDE INDUSTRIES NVTA-16/NVTAS 212 WITH 8-10d NAILS x 1 1/2" INTO STRAP PER NOA 03-0327.14 ROOF NAILING SCHEDULE MARK EDGE NAILING (E,N.) BOUNDARY NAILING (B,N) FIELD NAILING (F.N.) 0 10d @ 4' 10ci @ 2 1/2" 1 O Co 6" NOTES: 1. 19/32' STRUC. I, EXTERIOR GLIDE, 5 PLY PL"NOOD SPAN INDEX (40/20) MINIMUM, 2. BLOCK ALL UNSUPPORTED EDGES. 1i A° rIv11 I WAI I I i (`r)r1RIf IATA PI F-PTRI aI rV mni IIT pPmNE=TRLT1r)r J !� F E D C B A INCORPORATED enginearing • architecture . planning 1.5.500 NEW BARN ROAD SurrE ,iw MIAMI LAKES, FLORIDA 32014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARGHITECT-AR 2808 0 A CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-1 I-2008 KFC 3601 S ORLANUO DRIVE SANFORD , FLORIDA K -y0_7 3/4" DIA. ANCHOR BOLTS @ 24" C.C. EMBED 7" INTO PROVIDE #3CONC, FOOTING, DOWELS ? 241 "19/32" 5 13/32" _ SILL PL. IF CONST, EXPANSION JOINT MATERI/ JOINT IS USED 4" GONG. SLAB SIDEWALK � PER PLAN PROVIDE #3 - DOWELS @ 24" IF CONST. JOINT IS USED SIDEWALK — 4' x4' x,1211 CONC. FOOTING . WITH 6#5 CONT. & 6#5 PERPENDICULAR. OPTIONAL CONST, JOINT 3/4' DIA, ANCHOR BOLTS @ 24" C.C. EMBED 7" INTO CONC. FOOTING, 19/32" 5 13/32/"SILL PL. EXPANSION JOINT MATERI/ / 41' CONC. SLAB PER PLAN 10 MIL. POLYETHYLENE MOISTURE BARRIER - IT N FOOTING @ FRONT TOWER 3/4" = V-0" 141 REINFORCED MASONRY - CONSTRUCTION NOTES N,T.s. 12 EXPANSION JOINT MATERIAL '1 1' x 16" CONC, CURB WITH 2#5 CONT. FINISHED GRADE, 6" BELOW FINISHED FLOOR, MIN,—\ a, EL. 0'-0" TOP OF SLAB c� �4 SLAB @ MOP SINK v=1'-0" F51 4" CONCRETE SLAB 10 MIL, POLYETHYLENE MOISTURE BARRIER 8" CONCRETE BLOCK (FILLED) '12" x 26" CONC. FTG. w/ 3 /A5 CONT& #3 @ 36" c/o ACROSS FOOTING @ DRIVE THRU 3/4" = 1'-0" I 6 RY .. ,. ...w uv vinivvniw livvn NOTE: GROUT FOR USE IN MASONRY SHALL CONFORM TO ASTM C476. 2500 PSI AT 28 DAYS. COURSE SAND OR PEA GRAVEL WITH SLUMP NOT GRATER THAN 8". JAMS AT MASONRY OPENING N.T.S. EXTERIOR INTERIOR #4 @ 12" O.C. 16" x,l 6" MONO�LITHI(EXPANSION JOINT MATERIAL 16" x '16" NIUNULITHIC CONCRETE FOOTINGCERAMIC TILE OVER CONC, WITH 2#5 CONT. SEE ROOM FINISH SCHEDULE i, 5'-U" �. 5'-0" , EL. 0'-0" "FOP OF SLAB Y 8" C.M.U. GROUT SOLID 12" x 24" CONC. FTG, w/ 3 #5 CONT & #3 @ 36" c/o ACROSS FOOTING @ REAR WALL �?a WALK-IN 3/4° NOTE: DEPTH OF FOOTING TO BE ESTABLISHED BY SITE-SPECIFIC SOILS REPORT, 8" MASONRY BLOCKw/ 9 GA. LADDER TYPE HORIZ, WALL REINF. (DUROWALL) @ 16" c/c FINISHED GRADE 6" BELLOW FINISHED FLOOR, MIN. OR SIDEWALK -SEE CIVIL DWGS EL, 0'-0" TOP OF SLAB m EXPANSION JOINT MATERIAL 4" CONCRETE SLAB 10 MIL. POLYETHYLENE MOISTURE BARRIER 8" CONCRETE BLOCK (FILLED) '12" x 24" CONC. FTG. w/ 3 #5 CONT & #3 C) 36" c/o ACROSS TYP. FOOTING 3/4" = 1'-0" EXTERIOR INTERIOR 8" C.M.U. GF30UT SOLID '12" x 24" CONC. FTG. w/3#5CON'r&#3@ 36" c/o ACROSS FOOTING @ FRONT & SIDE ENTRY 314`=P -O` HOLD REINFORCEMENT IN POSITION AT INTERVALS OF 96 CONCRETE MASONRY W/ "REBAR POSITIONERS" AS MANUFACTURED BY VERT. RFINF. FULL HEICHT OF WALL A. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE ALL REINFORCEMENT SHALL BE ANCHORED HORIZONTAL JOINT REINFORCEMENT IN POSITION PRIOR TO PLACING GROUT. BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES (ACI 530-02/ SPLICE VERTICAL BARS WITH MECHANICALCONC. - TWO COURSE (16") MAXIMUM SPACING COUPLERS WHICH DEVELOP 125% OF ASTM ASCE 5-92) AND SPECIFICATIONS FOR MASONRY STRUCTURES (ACI 530.1-02/ - AT TWO COURSES IMMEDIATELY ABOVE AND BELOW ALL WALL OPENINGS ASCE 5-95). DIA. LAPS. (LAP W/ FTC. DOWELS 12" MIN.) L�\ #6 @ 32" U.C. REINF. MORTAR JOINT THICKNESS B. COMPRESSIVE STRENGTH OF THE MASONRY SHALL EQUAL OR EXCEED - THEORETICAL = 3/8" Cm = 1500 PSI. DETERMINATION OF COMPRESSIVE STRENGTH SHALL BE 1 #6 AT OPENINGS & CORNERS - MAXIMUM ACTUAL = 1/2" BASED ON THE UNIT STRENGTH METHOD, VERTICAL CONTROL (SHRINKAGE) JOINTS C. CONCRETE MASONRY UNITS SHALL CONFORM TO ASTM C90 TYPE N -II, NORMAL - AT 26 FEET MAXIMUM HORIZONTAL SPACING DUROWALL HORIZ. 9 GA. WEIGHT. THE COMPRESSIVE STRENGTH OF THE UNITS SHALL BE 1900 PSI - AT CHANGES IN WALL HEIGHT OR THICKNESS MINIMUM ON THE NET AREA. SAMPLING AND TESTING OF UNITS SHALL BE - AT CONSTRUCTION JOINTS IN FOUNDATION, ROOF OR FLOORS -; IN ACCORDANCE WITH ASTM C140 FOR ALL REQUIREMENTS OF ASTM C90 �-- - AT CHASES AND RECESSES FOR PIPING, COLUMNS, FIXTURES, ETC, PLACE METAL CAP EXCEPT MOISTURE CONTENT. FOR GROUTING APPLICATIONS, THE MINIMUM - AT ABUTMENTS OF WALLS AND COLUMNS GROUT SPACE DIMENSIONS SHALL BE IN ACCORDANCE WITH TABLE 4.3.3.4 OR WIRE SCREEN - AT RETURN ANGLES OF "L", "T" OR "U" SHAPED STRUCTURES OF ACI 530.1-92/ASCE 6-92. - AT ONE OR BOTH SIDES OF WALL OPENINGS D. MORTAR SHALL CONFORM TO ASTM C270. TYPE S SHALL BE USED FOR ALL \N CONCRETE MASONRY BOND BEAMS REINFORCED WITH A MINIMUM OF 2-#5 WORK IN CONTACT WITH THE GROUND, TYPE S SHALL BE USED FOR ALL REBARS EXTENDING 24" PAST EDGES OF OPENINGS FILLED WITH GROUT TO CONFINE CONCRETE EXTERIOR WALLS AND ALL INTERIOR LOAD BEARING WALLS. PRIOR TO - BELOW SILL IN WALLS WITH OPENINGS THE START OF MASONRY WORK, THE CONTRACTOR SHALL SUBMIT MORTAR - AT THE TOP OF WALLS U,N.O. MATERIAL SPECIFICATIONS AND PROPORTIONS INTENDED FOR USE IN THE CONSTRUCTION. J. WHERE VERTICAL CELLS ARE SHOWN REINFORCED AND FILLED, CONSTRUCT WITH CELLS ALIGNED AND ADJACENT WEB JOINTS MORTARED SOLID TO PRE -CONSTRUCTION AND CONSTRUCTION EVALUATION OF MORTARS SHALL BE PREVENT THE SPREAD OF GROUT BEYOND GROUTED CELLS. DONE IN ACCORDANCE WITH ASTM C780. COMPRESSIVE STRENGTH REQUIRE- K. ALL MASONRY SHALL BE LAID IN RUNNING PATTERN, IN EACH WITH OF MENTS LISTED IN ASTM C270 NEED ONLY BE MET FOR THE LABORATORY MASONRY, HEAD JOINTS IN SUCCESSIVE COURSES SHALL BE OFFSET. A SAMPLES MIXED TO THE CONSISTENCY OF THAT SPECIFICATION. MINIMUM OF ONE QUARTER THE UNIT LENGTH E. FOR GROUTED MASONRY, THE STRENGTH OF GROUT DETERMINED IN ACCOR- DANCE WITH THE PROVISIONS OF ASTM C1019 SHALL BE AT LEAST EQUAL TO L. INTERSECTING WALL UNITS SHALL BE LAID IN AN OVERLAPPING MASONRY Cm BUT NOT LESS THAN 2500 PSI. THE SLUMP OF THE GROUT SHALL BE BONDING PATTERN ON 50% OF THE UNITS WITH ALTERNATE UNITS HAVING BETWEEN 8 AND 11 INCHES, A BEARING OF NOT LESS THAN 3 INCHES ON THE UNIT BELOW, F. REINFORCING BARS SHALL CONFORM TO ASTM A615 GRADE 60 UNLESS NOTED M. ALL CONCRETE MASONRY WALLS NOT SUPPORTED LATERALLY AT INTER - OTHERWISE. SECTING WALLS, FLOORS OR OTHER STRUCTURAL MEMBERS BY BOND ACTION G. HORIZONTAL JOINT REINFORCEMENT SHALL CONFORM TO ASTM A82 SHALL BE ANCHORED TO THESE MEMBERS WITH HOOKED WIRE DOVETAIL MANUFACTURED IN A TRUSS TYPE CONFIGURATION. COATINGS FOR CORROSION ANCHORS INTO THE GROUTED CELL OR BOND BEAM. PROTECTION SHALL CONFORM TO SECTION 3.2.1.4 OF ACI 530.1-88/ASCE 6-92. N. DOVETAIL ANCHORS, WALL PLUGS, ACCESSORIES AND OTHER MISCELLANEOUS H. MOVEMENT JOINTS ITEMS SHALL BE INSTALLED AS THE MASONRY WORK PROGRESSES. CONTROL JOINTS 0. ALL WALLS SHALL BE GROUTED SOLID FROM THE FOOTING'TO THE FINISHED ACI 530.1-02/ASCE 5-95 SECTION 2.2.6.1 SLAB ON GRADE AND SHALL INCLUDE 1-#5 CONTINUOUS AT THE FLOOR LEVEL. EXPANSION JOINTS P. STORE BLOCKS ON PALLETS AND COVER WITH VISQUEEN, ACI 5:50.1-02/ASCE 5-95 SECTION 2.2.6.2 Q. USE ALL MORTAR WITHIN 2 HOURS OF MIXING AT TEMPERATURES OF 80 DEG. F. (2-1/2 HOURS AT TEMPERATURES BELOW 50 DEC. F.) I. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, THE FOLLOWING MINIMUM LOCATIONS AND MAXIMUM SPACINGS OF THE LISTED ITEMS SHALL APPLY: REINFORCED AND FILLED VERTICAL CELLS (#7 TYP. U.N.O.) - ONE CELL AT 32" O.C. IN EXTERIOR WALLS U.N.O. - ONE CELL EACH SIDE OF OPENING - ONE CELL IN EACH CORNER - ONE CELL IN EACH INTERSECTION - ONE CELL EACH SIDE OF VERTICAL WALL JOINTS REINFORCING BAR SPLICES WHERE REQUIRED = 48 BAR DIAMETERS REINFORCED MASONRY - CONSTRUCTION NOTES N,T.s. 12 EXPANSION JOINT MATERIAL '1 1' x 16" CONC, CURB WITH 2#5 CONT. FINISHED GRADE, 6" BELOW FINISHED FLOOR, MIN,—\ a, EL. 0'-0" TOP OF SLAB c� �4 SLAB @ MOP SINK v=1'-0" F51 4" CONCRETE SLAB 10 MIL, POLYETHYLENE MOISTURE BARRIER 8" CONCRETE BLOCK (FILLED) '12" x 26" CONC. FTG. w/ 3 /A5 CONT& #3 @ 36" c/o ACROSS FOOTING @ DRIVE THRU 3/4" = 1'-0" I 6 RY .. ,. ...w uv vinivvniw livvn NOTE: GROUT FOR USE IN MASONRY SHALL CONFORM TO ASTM C476. 2500 PSI AT 28 DAYS. COURSE SAND OR PEA GRAVEL WITH SLUMP NOT GRATER THAN 8". JAMS AT MASONRY OPENING N.T.S. EXTERIOR INTERIOR #4 @ 12" O.C. 16" x,l 6" MONO�LITHI(EXPANSION JOINT MATERIAL 16" x '16" NIUNULITHIC CONCRETE FOOTINGCERAMIC TILE OVER CONC, WITH 2#5 CONT. SEE ROOM FINISH SCHEDULE i, 5'-U" �. 5'-0" , EL. 0'-0" "FOP OF SLAB Y 8" C.M.U. GROUT SOLID 12" x 24" CONC. FTG, w/ 3 #5 CONT & #3 @ 36" c/o ACROSS FOOTING @ REAR WALL �?a WALK-IN 3/4° NOTE: DEPTH OF FOOTING TO BE ESTABLISHED BY SITE-SPECIFIC SOILS REPORT, 8" MASONRY BLOCKw/ 9 GA. LADDER TYPE HORIZ, WALL REINF. (DUROWALL) @ 16" c/c FINISHED GRADE 6" BELLOW FINISHED FLOOR, MIN. OR SIDEWALK -SEE CIVIL DWGS EL, 0'-0" TOP OF SLAB m EXPANSION JOINT MATERIAL 4" CONCRETE SLAB 10 MIL. POLYETHYLENE MOISTURE BARRIER 8" CONCRETE BLOCK (FILLED) '12" x 24" CONC. FTG. w/ 3 #5 CONT & #3 C) 36" c/o ACROSS TYP. FOOTING 3/4" = 1'-0" EXTERIOR INTERIOR 8" C.M.U. GF30UT SOLID '12" x 24" CONC. FTG. w/3#5CON'r&#3@ 36" c/o ACROSS FOOTING @ FRONT & SIDE ENTRY 314`=P -O` HOLD REINFORCEMENT IN POSITION AT INTERVALS OF 96 DIA'S (MAX.) NOTE: W/ "REBAR POSITIONERS" AS MANUFACTURED BY VERT. RFINF. FULL HEICHT OF WALL AA WIRE PRODUCTS OR EQUAL, (MIN. OF 2 PER BAR.) PROVIDE STANDARD 90 HOOKS ALL REINFORCEMENT SHALL BE ANCHORED AT EACH END IN POSITION PRIOR TO PLACING GROUT. W750279 SPLICE VERTICAL BARS WITH MECHANICALCONC. BOND BEAM COUPLERS WHICH DEVELOP 125% OF ASTM SPECIFIED YIELD STRENGTH, OR 48 x BAR DIA. LAPS. (LAP W/ FTC. DOWELS 12" MIN.) L�\ #6 @ 32" U.C. REINF. CENTERED IN BLOCK CAVITY (U.N.O.) 1 #6 AT OPENINGS & CORNERS DUROWALL HORIZ. 9 GA. LADDER TYPE EVERY -; �-- PLACE METAL CAP OTHER COURSE (16"O.C.) OR WIRE SCREEN MIN. LAP OF 12 INCHES �'' UNDER BOND BEAM \N TO CONFINE CONCRETE EXCEPT AT FILLED CELLS PROVIDE INSPECTION HOLES AT BOTTOM OF FOUR/LIFT '- FOOTING CELLS CONTAINING STEEL ARE FILLED W/ GROUT; VERT. CELL SHOULD PROVIDE A CONTINUOUS CAVITY FREE OF MORTAR DROPPINGS, AND AT LEAST PLACE MORTAR ON CROSS 3"X4" IN SIZE. AT TOP OF WEBS ADJACENT TO CELLS INTERMEDIATE GROUT LIFT, HOLD WHICH WILL BE GROUTED, GROUT 2" BELOW TOP OF BLOCK TO PREVENT LEAKAGE. TYP. REINF, MASONRY CONSTRUCT'N N.T.S. 1 $ GRADE CONFIRM SLAB EXTENSION WITH W.I.C./W.I.F. BOX MFR, (6" iVIIN.) CONT, ANGLE SUPPLIED BY FREEZER MAUNF• * I WALK-IN UNIT #4 AT 12"c/c x 5'-0" LONG WITH STANDARD HOOK I1= II—I r= 4" CONCRETE SLAB -III — I=I 1 I—III—I' WITH 6"x6" VVI A x WI A W.VPLF. III—I ——III' OVER 10 MIL VAPOR BARHER 16" x 16" MONOLITHIC FOOTING WITH 2#5 CONT. r FOOTING @ WALK-IN N. -T. S 1 4 I INCORPORATED engineering. architecture. planning 15500 NEVA/ BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-41124 FAX: (305) 826-0619 EB#0004432 L� C0 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING-; DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 DETAILSSTRUCTURAL X(2) 2x6 DBL PLATE 2x6 VERT. BLOCKING 24" O/C. W/ (2) 16d — EA. END, EA. SIDE (SEE SPLICE DETAIL '15/S4.1 18'-10' J t, 0 ROOF TRUSSES, TYP. —�� '1810 DBL PLATE ' C A35, TYP. SIMPSON OTC ROOF TRUSS CLIP ON BOTH SIDES PARALLEL TO FRAMING CKF= 11 - 811x 3/8" 0 LAG ��U� BOLTS C 16"O.C. IN 0.145".B @ 32" 0, 0. POWDER ACTUATED 2x6 MIN. TRUSS PARAPET LEC; 1/4" DRILLED FASTENER WITH (2)-7/8" WASHERS W/ B`( TRUSS MANUF. HOF,IZONTAF L INCORPORATED x 6 BRACING GHU HOLES. MIN 1 I/2 EMBED AT 32' O.C. AT ALL ROOF LEVELS engineering AT TOP PLATE AND AT • architecture .planning SILL PLATE MID-POINT BETWEEN SAID 2x6 BLOCKING '15500 NEW BARN ROAD LOCATIONS OR AT PLYWD, SUITE 106 PANEL POINTS (EDGES) MIAMI LAKES , FLORIDA 330'14 SPLICES NOT TO i EXCEED 16' c/c (VERT.) 19/32' APA RATED PLYWOOD PHONE: (305) 558 4124 y A c Q FAX: (305) 826-0619 /-r - - - PERPENDICULAR TO STUDE&#0004432 � - - - - - - rfj BUILD-OUT ATTACHMENT N.T.S, 17SUPPORT- PARALLEL TO TRUSS I/2" = 1' U" 13 NOT USED N.T.S. � S4.1 � lj 2x6 HORIZ. BRACING AT 'I G" o.c. MAX. SEAL (STA(:,(,ERED TO ALLOW LE FOR END NAILS) EDUARDO L. CARCACHE o o CJJ CKIVIL D�RAUDENBUSHLt ROOF TRUSSES, TYP. SHEA-I I-iIN(:� TRUSS ANCHOR PER SCHEDULE ARCHITECT-AR 2808 16 (3) -16d NAILING THRU ON SHEET S-3 m--n 54.1 SIMPSON OTC ROOF TRUSS VERTICAL TRUSS WEB (& I I INTO END OF HORIZ. CLIP ON BOTH SIDES I I BRACE —� 12-0-0' _ T.O. BOND BEAM — T & TRUSS BEARING �►:' — 0.145"0 a 32" O.C. POWDER ACTUATED 24 MIN, TRUSS PARAPET LEG— FASTENER WITH (2)-7/8" WASHERS W/ — `--- BY TRUSS MANUF, MEN MIN 1 1/2" EMBED AT 32" O.C. - 8"X24" BEAM WITH (1) c - NOTE: cv #7 ci> TOP &- TRUSS MANUF. TO DESIGN WEB OF ALL SIL_ PLATE BOTTOM �,,, �, TRUSSES BEARING A'f EXTERIOR WALL. 2x6 HORIZ. BRACIN(a ' - TO TRANSFER HORIZONTAL FORCE OF A 16" o.c, MAX. G75 LBS. FROM PLYWOOD DIAPHRAGM (S fAGGERED TO ALLOW TO TRUSS BEARING. FOR END NAILS) Ln Co CL r >- ca r NOT USED 1 1/2" =1' o° 1 SUPPORT PERP. TO TRUSS I/2" =1' o° 14 NOT USED N.T3, 1101 N BRIDGING DETAIL 3° = 1' 0" E REAR AND FRONT WALL @TRUSS 3/4° = V-01' 21 (3) 1 End NAILS Al- EACH x JOINT CONNECTION - TYP. N 61-0" MIN. G-0" MIN. Y T.0, DBL PLATE 0 (2) 2x6 PLATE (.`EE SPLICE Q DETAIL 15/54.1) ELEVATION 2x6 DOUBLE TCP PLATE, TYP. or F1 _4 (2) 24 STUDS EACH SIDE OF T.O. DBL PLATE .10d g 41' BETWEEN TRUSS AND Q LOWERED PARAPET AREA (2) 2x6 —�-1-8-10_DB TYP. PLYWOOD -TYPICAL T.O. DBL PLATE � 16d (3) 16d NAILS AT EACH JOINT CONNECTION - TYP. 0 + + 3.1 31, + Q PLAN - NAILING STAGGER 19/32" APA RATED PL`MJOOD HORIZONTAL 2 x 6 BRACING CONTRACT DATE: 10-28-2007 AT ALL ROOF LEVELS 24 MIN, TRUSS PARAPET LEG AT TOP PLATE AND AT BY TRUSS MANUF. BUILDING TYPE: K-y07 MID-POINT BETWEEN SAID 2x6 BLOCKING TYPICAL - ALL DOUBLE PLATE CONDITIONS - U.O.N. LOCATIONS OR AT PLYWD, PLAN VERSION: 2007 D PANEL POINTS (EDGES)F=,l PREFABRICATED WOOD TRUSS SITE NUMBER: 297909 >_ r SPLICES NOT TO EXCEED 1h" 0, (VERT,)9/32" APA RATED PLYWOOD STORE NUMBER: W750279 N®$' USED 1 PLATE LAP DETAIL N.T.S. 1 5 PARAPET STEPDOWN ELEVATION N,T,S.1 1 DRA1�lING DATE: 3-1'I-2008 VARIES --- -- --- - ROOF DEC KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA TRUSS ANCHOR TRUSS PER SCHEDULE ON SHEET S-3 171 2x4 II 7z II + II —' T.O. BOND BEAM _ —TO + &TRUSS BEARIiNO "''`:'- r<: Al NOTE: H (3) 16d - = TRUSS MANUF, TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALL. 2x WD, BLOCKING - - TO TRANSFER HORIZONTAL FORCE OF STRUCTURAL A BETWEEN TRUSSES - 675 LBS. FROM PLYWOOD DIAPHRAGM - TO TRUSS BEARING. 2x4\\_8"x DETAILS 1BOND BEAM W/2#7 PROVIDE 2#7 CORNER BARS ������ AT EACH CORNER, BEND 3'-U" EACH LENGTH 8" MASONRY n NOT USED BRIDGING LAP DETAIL N,T.S. 1161 NOT USED N. r.s, F12 NOT USED N.T.S._ PLOT DATE: 2008 8 SIDE WALL @TRUSS 3/4„ - 1L-L4 CONNECTION TYPE, NAILING: 1. JOIST TO SILL OR GIRDER, TOENAIL (3 8d) 2. BRIDGING TO JOIST, TOENAIL EACH END (2-8d) 3. 1"x6" (25MMx152MM) SUBFLOOR OR LESS TO JOIST, FACE MAIL (2-8d) 4. WIDER THAN 1" X 6"(25MMx-152MM) SUBFLOOR TO JOIST, FACE NAIL (3-8c1) 5. 2" (52MM) SUBFLOOR TO GIRDER, BLIND AND FACE NAIL (2-'16d) 6. SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL (16d @16" O.C.) 7. SOLE PLATE TO JOIST OR BLOCKING, AT BRACED W. PANELS (3-16d PER '16") 8. TOP PLATE TO STUD, END NAIL (2-16d) 9, STUD TO SOLE PLATE (2-16d END NAIL) '10. DOUBLE STUDS, FACE NAIL (16d @ 24", O.C.) 'I'1. DOUBLE TOP PLATES, TYPICAL FACE NAIL ('16(j @ 16" O.C.) 12• DOUBLE TOP PLATES, LAP SPLICE (8-16c1) 13. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOENAIL (3-8d) -14. RIM JOI ST TO TOP PLATE, TOENAIL (8d C 61' O.C.) 15. TOP PLATES, LAPS AND INTERSECTIONS, FACE NAIL (2-1 CD) 16. CONTINUOUS HEADER, TWO PIECES (16d a 16" U.C. ALONG EDGE) 17. CEILING JOISTS TO PLATE, TOENAIL (8-8d) 18. CONTINUOUS HEADER TO STUD, TOENAIL (4-8d) 19. CEILING JOISTS, LAP OVER PARTITIONS, FACE NAIL (3-'16d) 20. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL (3-16d) 2'1. RAFTER TO PLATE, TOENAIL (3-8d) 22. 1" (25MM) BRACE TO EACH STUD AND PLATE, FACE NAIL (2-8d) 23. 1 "x8" SHEATHING OR LESS TO EACH BEARING, FACE NAIL (2-8d) 24. WIDER THAN 1"x8" SHEATHING TO EACH BEARING, FACE NAIL (3-8d) 25. BUILT-UP CORNER STUDS (16d r- 24" O.C.) 26. 2" PLANKS (2-16d AT EACH SPLICE) 27. 2x6 BOX BEAM / HEADER (12d @ 12" O.C.) U 28, BUILT-UP GIRDER AND BEAMS (20d @ 32" O.C. AT TOP & BOTTOM AND CC STAGGERED 2-20d AT ENDS AND AT EACH SPLICE) y_' NAILING SCHEDULE N.T.S, NOTE: REFER TO DETAIL 4/S4.1 FOR 2 x 6 CATS A( 16" c/c AND PLYWOOD INFORMATION FOR PARAPET WALL LEW; m EL. 11'-0" - TRUSS D v � U NOTE: TRUSS MANUF. TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS. FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. (TYPICAL EACH END) TRUSS DIAGRAM "3" N.T.s. 19 BOUNDARY NAIL (B.N.) FOR BLDG. PERIMETER 2x4 FLAT BLK'G UNSUPPORTED EDGES PER PLAN - WHEN EN• IS LESS THAN 4" O.C. USE 3x4 BLKG MIN. LONG DIMENSION OF PLYWOOD TO RUN PERPENDICULAR TO JOISTS EDGE NAIL (E.N.) @ PLYWD. PERIMETER STAGGER PLYWD, JOINTS FIELD NAIL (F.N.) a ALL INTERMEDIATE MEMBERS � NOTES: x 1. MIN. PLYWD• SHT. SIZE SHALL BE 2-0"X 4'-0" N 2, MIN. 3/8" NAILING EDGE DISTANCE. a 3. EDGE NAIL (E.N) 0/ BEAMS AND AROUND ALL OPENINGS. cr� v� ROOF NAILING PLAN N.T.S, 13 1/8" GAP J I PLYWOOD ROOF DECK SHEATHING 1 O EDGE NAIL, STAGGER, U.0•N• 2x BLOCKING (2) 4 x 19" x 3/81 BENT PLATE BONI 3/4'' DIA. THRU DLT FOR THREE F FOUR TRUSS ISOMETRIC SCHEDULE 2x6 REO'D. EQUAL EQUAL MARK DESCRIPTION < 1 4°x19"x3/8" BENT STEEL PLATE (Fy=36 ksi). SEE DETAIL 1/S4.2 2 TWO (2), 3/4" DIA. THRU BOLT FOR TWO & THREE PLY TRUSS 3 5/8" DIA., "HILTI KWIK BOLTS II, 2 REWD. EL. 11'-0" - TRUSS D v � U NOTE: TRUSS MANUF. TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS. FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. (TYPICAL EACH END) TRUSS DIAGRAM "3" N.T.s. 19 BOUNDARY NAIL (B.N.) FOR BLDG. PERIMETER 2x4 FLAT BLK'G UNSUPPORTED EDGES PER PLAN - WHEN EN• IS LESS THAN 4" O.C. USE 3x4 BLKG MIN. LONG DIMENSION OF PLYWOOD TO RUN PERPENDICULAR TO JOISTS EDGE NAIL (E.N.) @ PLYWD. PERIMETER STAGGER PLYWD, JOINTS FIELD NAIL (F.N.) a ALL INTERMEDIATE MEMBERS � NOTES: x 1. MIN. PLYWD• SHT. SIZE SHALL BE 2-0"X 4'-0" N 2, MIN. 3/8" NAILING EDGE DISTANCE. a 3. EDGE NAIL (E.N) 0/ BEAMS AND AROUND ALL OPENINGS. cr� v� ROOF NAILING PLAN N.T.S, 13 1/8" GAP J I PLYWOOD ROOF DECK SHEATHING 1 O EDGE NAIL, STAGGER, U.0•N• 2x BLOCKING (2) 4 x 19" x 3/81 BENT PLATE BONI 3/4'' DIA. THRU DLT FOR THREE F FOUR TRUSS ISOMETRIC BENT PLATE DETAIL N.T.S. I 9 1 N OTE: TRUSS MANUF, TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS, FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. N U -VU E- NVTA-'16/ NVTAS212 STRAP WITH 8-1 Od x 1.5" NAILS TO TRUSS CD c cn PLYWOOD EDGE BLOCKING N.T.S. 14 DETAIL FOR TRUSS CONNECTION 3 N.-T.s. V -( i _ - �-?T- PLYWOOD SHEATHING JOIST,RAFTERS OR TRUSS U.N.O. • •1 f + JOIST HANGERS - OPENING SEE NOTE BELOW ' PER PLANS + * p- FUND. EDGE 1 7 - NAILING (E,N.) t AROUND l OPENING NOTE: HANGERS SHALL BE "SIMPSON" STANDARD "U" @ ROOF. DBL. JOIST OR RAFTERS SHALL BE JOINED TOGETHER AS FOLLOWS: 1.10" OR LESS NOM. DEPTH - 16d @1211 O.C. STAGGERED 2. MORE THAN 10" - (2)16d a 12" O.C. DOUBLE 2x HEADER SAME SIZE AS JOIST OR RAFTER U•N•O. 4 a O a co TYPICAL ROOF OPENING ROOF SCHEMATIC BRACING DETAIL N.T.S, TRUSS SCHEDULE DOUBLE TRUSS MARK DESCRIPTION T1 1 4°x19"x3/8" BENT STEEL PLATE (Fy=36 ksi). SEE DETAIL 1/S4.2 2 TWO (2), 3/4" DIA. THRU BOLT FOR TWO & THREE PLY TRUSS 3 5/8" DIA., "HILTI KWIK BOLTS II, 2 REWD. 0 4 PREFABRICATED TWO OR THREE PLY TRUSS 5 MIN. 19/32" EXTERIOR GRADE PLYWOOD. SEE PLAN FOR NAILING REWMTS. 6 MIN. 8"x12" CONCRETE TIE BEAM (f = 3,000 psi, MINIMUM) 7 CONCRETE MASONRY BLOCK X BENT PLATE DETAIL N.T.S. I 9 1 N OTE: TRUSS MANUF, TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS, FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. N U -VU E- NVTA-'16/ NVTAS212 STRAP WITH 8-1 Od x 1.5" NAILS TO TRUSS CD c cn PLYWOOD EDGE BLOCKING N.T.S. 14 DETAIL FOR TRUSS CONNECTION 3 N.-T.s. V -( i _ - �-?T- PLYWOOD SHEATHING JOIST,RAFTERS OR TRUSS U.N.O. • •1 f + JOIST HANGERS - OPENING SEE NOTE BELOW ' PER PLANS + * p- FUND. EDGE 1 7 - NAILING (E,N.) t AROUND l OPENING NOTE: HANGERS SHALL BE "SIMPSON" STANDARD "U" @ ROOF. DBL. JOIST OR RAFTERS SHALL BE JOINED TOGETHER AS FOLLOWS: 1.10" OR LESS NOM. DEPTH - 16d @1211 O.C. STAGGERED 2. MORE THAN 10" - (2)16d a 12" O.C. DOUBLE 2x HEADER SAME SIZE AS JOIST OR RAFTER U•N•O. 4 a O a co TYPICAL ROOF OPENING ROOF SCHEMATIC BRACING DETAIL N.T.S, TRUSS SINGLE TRUSS DOUBLE TRUSS BEARING POINT COMMENTS T1 X 0 T2 X J 0 T3X 0 SEE NOTE %� I BELOW T4 '10-28-2007 K -y07 2007-D 297909 W750279 3-'11-2008 X SEE NOTE #1 BELOW T5 X END JACKS NOTES: 1. T-3 &T-4 SHALL BE DOUBLE THICKNESS TRUSS AS REQUIRED BY TRUSS DESIGN, 2. HOLDD OWN CONNECTORS SHALL BE SPECIFIED BY SITE SPECIFIC ARCHITECT/ ENGINEER BASED UPON LOADING DATA PROVIDED BY TRUSS DESIGNER. 3. PROVIDE SHOP DRAWINGS PRIOR TO FABRICATION, 4. TRUSS MEMBER SIZES ARE FOR REFERENCE ONLY. ACTUAL SIZE SHALL BE., DETERMINED BY TRUSS MANUFACTURER BASED ON ACTUAL LOAD CONDITIONS AND CODES. L TRUSS SCHEDULE NOTE: TRUSS MANUF. TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS. FROM PLYWOOD WOOD DIAPHRAGM TO TRUSS BEARING. NU-VEU INDUSTRIES NVHTA-16H WITH DOUBLE NVHTA20 STRAPS & 20G SEAT WITH 16-10d X 1 1/2" NAILS INTO STRAPS & 6-10d x 1 1/2" NAILS INTO SEAT PER PER NOA-04.0510.03 BOND BEAM RAP CAPACITY: UPLIFT = 3,117POUNDS HORZ. SHEAR (L-1) = 1,575 POUNDS (L-2) = 2,175 POUNDS DETAIL FOR TRUSS CONNECTION 1 N.T.S. 12 18'-10' _ T•0, TRUSS TRUSS MANUFACTURER TO DESIGN VERTICAL LEGS AS PART OF TRU S S - INCREASE SIZE AS NECESSARY - 2°X6° MINIMUM, SECTION TWO PLY TRUSS (MAX. UPLIFT=6,224#) HORIZ. = 4945# 4 3/4"--� THREE PLY TRUSS (MAX. UPLIFT=6,224#) HORIZ. = 4945# DETAIL FOR TRUSS CONNECTION 2 N.T.S, MIN, 16" DIAMETER CLEARANCE AREA REQUIRED FOR HVAC DUCT & INSULATION, SLOPE: 1/4" PER FT. I- -1 f m s -� i` 12'-0" �❑ TRUSS BEARING �� / "--MIN, 16" SQUARE CLEARANCE U 'L-C2J 7 EQUAL SPACES AREA REQUIRED FOR HVAC DUCT & INSULATION.(TYP) CONT 2X4 LATERAL BRACING AT 48"O.C, MIN. OR PER TRUSS DESIGN LAID FLAT & NAILED TO TOP OF BOTTOM CHORD. NOTE: ALL WEBS MUST ALIGN BETWEEN TRUSSES, APPLY MOST STRINGENT STANDARD. X T.O. TRUSS - v 12'-0" TRUSS BEARING .Q X TRUSS MANUFACTURER TO DESIGN VERTICAL LEGS AS PART OF TRUSS - INCREASE SIZE AS NECESSARY - 2"X6" MINIMUM. MIN. 16" DIAMETER CLEARANCE AREA REQUIRED FOR HVAC DUCT &INSULATION. SLOPE: -1/4" PER FT. NOTE: TRUSS MANUF. TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. (TYPICAL EACH END) T2 TRUSS ELEVATION N.T.s. 2x6 MIN. O2x4 MIN, NOTE: TRUSS MANUF. TO DESIGN WEB OF ALL TRUSSES BEARING AT EXTERIOR WALLS TO TRANSFER HORIZONTAL FORCE OF 675 LBS FROM PLYWOOD DIAPHRAGM TO TRUSS BEARING. (TYPICAL EACH END) T2 TRUSS ELEVATION N.T.s. -MIN. 1t" SQUARE CLEARANCE 7 EQUAL SPACES AREA REQUIRED FOR HVAC I DUCT & INSULATION,(iYP) ROUGH OPE NGS ARE NOT CONT 2X4 LATERAL BRACING AT 48"O.C. MIN. OR PER TRUSS DESIGN LAID FLAT & TRj"E N , Y��{{To ST 1■ 2x6 MIN, NAILED TO TOP OF BOTTOM CHORD. TR j IC719�i *H d APPLY MOST STRINGENT STANDARD. LO �,d� TA N� 2 2x4 MIN. NOTE: ALL WEBS MUST ALIGN BETWEEN TRUSSES. �V �� 71 TRUSS ELEVATION 1/4" =1'-0" 30 PSF LIVE LOAD 15 PSF DEAD LOAD (APPLY TO TOP CHORD) 10 PSF DEAD LOAD NOTE: (APPLY TO BOTTOM CHORD) ALSO, APPLY ROOF TOP MECHANICAL POINT LOADS. WEIGHT AND LOCATION OF UNITS ARE SHOWN ON THIS SHEET AND ARE NOT INCLUDED IN THE ABOVE LOADING DIAGRAM, VERIFY THESE LOADS WITH MECHANICAL SUPPLIER BEFORE DESIGNING TRUSS, co n ccs -4- APPLY TO END VERTICAL LEG OF TRUSSES (PARAPET WALL) TRUSS DESIGN CRITERIA N.T.s, I 4 I CK GROUW INCORPORA-FED engineering . architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-06'19 EB -%0004432 v SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 IL 0 0 J -MIN. 1t" SQUARE CLEARANCE 7 EQUAL SPACES AREA REQUIRED FOR HVAC I DUCT & INSULATION,(iYP) ROUGH OPE NGS ARE NOT CONT 2X4 LATERAL BRACING AT 48"O.C. MIN. OR PER TRUSS DESIGN LAID FLAT & TRj"E N , Y��{{To ST 1■ 2x6 MIN, NAILED TO TOP OF BOTTOM CHORD. TR j IC719�i *H d APPLY MOST STRINGENT STANDARD. LO �,d� TA N� 2 2x4 MIN. NOTE: ALL WEBS MUST ALIGN BETWEEN TRUSSES. �V �� 71 TRUSS ELEVATION 1/4" =1'-0" 30 PSF LIVE LOAD 15 PSF DEAD LOAD (APPLY TO TOP CHORD) 10 PSF DEAD LOAD NOTE: (APPLY TO BOTTOM CHORD) ALSO, APPLY ROOF TOP MECHANICAL POINT LOADS. WEIGHT AND LOCATION OF UNITS ARE SHOWN ON THIS SHEET AND ARE NOT INCLUDED IN THE ABOVE LOADING DIAGRAM, VERIFY THESE LOADS WITH MECHANICAL SUPPLIER BEFORE DESIGNING TRUSS, co n ccs -4- APPLY TO END VERTICAL LEG OF TRUSSES (PARAPET WALL) TRUSS DESIGN CRITERIA N.T.s, I 4 I CK GROUW INCORPORA-FED engineering . architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-06'19 EB -%0004432 v SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 I KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA 0 0 0 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: '10-28-2007 K -y07 2007-D 297909 W750279 3-'11-2008 I KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA EL, 12'-0" - ---------------------------------------------------------------------------T1 - - EL. 16-10' II II II II II II II II II II II II IL--------- ----------- JI 1 h rl A l rl Mf A K A T /n IvI\JV IV I v iklu I V MVV I V — — — EL. 121-0" — — — EL. 10''-0' DRIVE THRU WINDOW - — — EL. 9'-4" EL. 0'-0" TOP OF SLAB LEFT SIDE ELEVATION 3/1611 _ .11 EL. 21'-4" F----------------------------------------------- I � I I I I EL. 18'-10' — - - - — rT------- -------------------------------------------- I I I I I I II I I II 6x8x15 CMU THIS AREA€ 6x8x16 CMU THIS AREA IL-------------- - - - - - - - --------------------------__ J -------------------------------------------� I # #6 g, 32" TYP. BOND BEAM TYP. i #5 C�� 40" TYP. BOND BEAM TYP. 5 Cn) 40" TYP. I TOP OF WALL ae-i I 2 #4 CONT, WALL as I I I I I c7 BEAM TOP OF EL. 12'-0" #3 HOOKED I I I i f EL, 12'-0" ..w.ww/:,»e M F- ..:.>h. yym+ .y c, « .� :;.r.n n ...:^.mow:; - .+r=', hi i 1, c »yaf...,w' .:;ty ..u..ay v,; .,* . ,•F p i ,.;:,::�::� t t,:. 2,06 CONT, I i 8IX 8ICONC ». w� „E1 .,� E COLUMN - = f:. _.: f:: ».# 3 ..N>.:::: -.. :.. , ....:::H .. .€ . EL 0'-011 - - MC816 - EL, U-0" TOP OF SLAB \\—MC816B \—MC816B i \—MC816 \—MC824 �MC824 LMC816 �MC816 EL.2'1'-4" - EL. '12'-0" - EL, 9'-4" - EL. 2'-8" - ------------------------I I I I I I I I �r--I------------------------ --------------------------------------- II I I II 6x8x16 CMU THIS AREA II I I II #6 @ 32" O.C. TYP. @ BEAMI __� IL__I------- t--------------------------------------- I RIGHT SIDE ELEVATION 3-16" = 11 - — EL. 18'-10" I 6x8x l6 CMU THIS AREA #5 @ 40" TYP,i BOND BEAM TYP. TOP OF WALL Fa -a --Il 1 _,,--2 #4 CONT. `MC816 �MC816 MC815 �MC816 MC824B --- I I I I I I I I I I I r�-------------- ----------------- I I I `--F� I I I I I I I I I I I I I I I I I I I I I I L__------____ II �vlvV i`J MVV �V MVV IV MVV IV IVI I.:U IV Iv11..V Itj EL. 21'-4" EL. 18'-10" EL, 121-01' )CATE GAS LINE ABOVE HOOD � D METAL PROTECTIVES EL. 8'-0" EL. 0'-0" TOP OF SLAB REAR ELEVATION 3/1611= 11 EL. 9'-4" EL. U-0" TOP OF SLAB FRONT ELEVATION 3/16" A. SOME ELECTRICAL JUNCTION BOXES / CONDUIT (REQUIRED FOR EXTERIOR LIGHT FIXTURES AND SIGNAGE) ARE LOCATED WITHIN CONCRETE POURS. INSTALL BOXES AND CONDUIT IN SUCH LOCATIONS PRIOR TO POURING OF CONCRETE. COORDINATE BOXES /CON DU IT WITH LOCATION OF STEEL REINFORCING. REFER TO ELECTRICAL SHEETS E3,2 AND E4.0. GROUP INCORPORATED engineering. architecture . planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES , FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 E B #0004432 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 �+ A :o�.nas�ssw sit- ramm 0 wrmr...►rsnswWArArMIRA HO8"O.C. 2 #6 CONT. tai 0 �M� m0via 0 1111mmill ��1�f CONTRACT DATE: BUILDING, TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: '10-28-2007 K -y07 2007-D 297909 W750279 3-11-2008 malloommall �msam+�wr�row� - EACH `MC816 �MC816 MC815 �MC816 MC824B --- I I I I I I I I I I I r�-------------- ----------------- I I I `--F� I I I I I I I I I I I I I I I I I I I I I I L__------____ II �vlvV i`J MVV �V MVV IV MVV IV IVI I.:U IV Iv11..V Itj EL. 21'-4" EL. 18'-10" EL, 121-01' )CATE GAS LINE ABOVE HOOD � D METAL PROTECTIVES EL. 8'-0" EL. 0'-0" TOP OF SLAB REAR ELEVATION 3/1611= 11 EL. 9'-4" EL. U-0" TOP OF SLAB FRONT ELEVATION 3/16" A. SOME ELECTRICAL JUNCTION BOXES / CONDUIT (REQUIRED FOR EXTERIOR LIGHT FIXTURES AND SIGNAGE) ARE LOCATED WITHIN CONCRETE POURS. INSTALL BOXES AND CONDUIT IN SUCH LOCATIONS PRIOR TO POURING OF CONCRETE. COORDINATE BOXES /CON DU IT WITH LOCATION OF STEEL REINFORCING. REFER TO ELECTRICAL SHEETS E3,2 AND E4.0. GROUP INCORPORATED engineering. architecture . planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES , FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 E B #0004432 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 KFC 3601 S ORLANDO DRIVE P.)ANFORD , FLORIDA K -yo 7 �-1 A 0 A 0 0 0 CONTRACT DATE: BUILDING, TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: '10-28-2007 K -y07 2007-D 297909 W750279 3-11-2008 KFC 3601 S ORLANDO DRIVE P.)ANFORD , FLORIDA K -yo 7 �-1 12 11 1 .10 1 9 1 8 1 7 I 6 1 5 1 4 1 3 I 2 Em TYPICAL EXTERIOR SHELL WALL: II 8x8x16 (NOM.) CMU. ALL CELLS FILLED VV/ FOAM, FOAMED IN PLACE INSULATION. PROVIDE 6" CMU RECESS (WHERE APPLICABLE). EXTERIOR FINISH ASSEMBLY: - EXTERIOR FINISH SYSTEM (SPEC. SECT. 09540). INTERIOR FINISH ASSEMBLY: INTERIOR SURFACE N DINING ROOM & RESTROOMS - STO "LEVELER SYSTEM", COMPLYVA// MANUFACTURERS SPECIFICATIONS. FINISH TEXTURE - SMOOTH TYPICAL EXTERIOR TOWER WALL: 2x6 WD STUDS AT '16" O.C. V// '1/2" EXTERIOR GRADE PLYUIU (CDX) SHEATHING. DRAINABLE EXTERIOR INSULATED FINISH ASSEMBLY: FLUID APPLIED AIR AND MOISTURE BARRIER (SPEC. SECT. 07195) REINFORCING MESH (SPEC. SECT. 07195), - RIGID INSULTATION (SPEC. SECT. 07210). EXTERIOR FINISH SYSTEM (SPEC. SECT. 07240), CONTACT FOR STO CORP.: TIM SALERNO 800-628-2738 x8502 (phone) 321-978-0267 (fax) tsalerno@stocorp. com TYPICAL INTERIOR WALL: 4" NOMI. METAL STUDS AT 16" O.C. (6" NOM. OR 8" NOM. WHERE NOTED). AT RESTROOMS: NATIONAL GYPSUM - 5/8" HI -IMPACT BRAND XP WALLBOARD. TYPE X CORE. NO SUBSTITUTIONS ALLOWED. AT KITCHEN: 1/2" CDX PLYWOOD W/ FRP SURFACE FINISH AT ALL OTHER FRAME WALL CONDITIONS: 1/2" GYPSUM WALLBOARD FINISHED AS SCHEDULED. '_�---,r�_, INTERIOR SOUND -RATED WALL: %'lef`V y 'CONSTRUCT TYPICAL INTERIOR WALL W/ 3-1/2" UNFACED r " FIBERGLASS BATT INSULATION. HOODWALL: TYP, CMU WALL WITH 20 GAGE S.S. PANEL BEHIND HOOD. REFER TO DETAIL 2/M3.0 FOR EXTENTS OF S.S. PANEL. SEE SCOPE OF WORK SHEET 1 1425, --------- DASHED LINE INDICATES INTERIOR SUBSTRATE LOCATION, ALL WALLS SHALL BE AS INDICATED EXCEPT FROM TOP OF SLAB TO 12" ABOVE SLAB SHALL BE 1/2" MOISTURE RESISTANT GYPSUM BOARD, U.0, N. THIS NOTE DOES NOT APPLY TO INTERIOR FACE OF RESTROOM WALLS. WALL LEGEND DIMENSIONS: A, ALL DIMENSIONS ARE TO FACE OF STUD OR CMU U.O.N. REFER TO FOUNDATION PLAN FOR FACE OF CONC. DIMENSIONS. B. DIMENSIONS NOTED AS "CLEAR' OR "HOLD' ARE MIN, REQ'D. NET CLEARANCE FROV FACE OF WALL. VERIFY FINAL EQUIPMENT SIZES W/ VENDOR PRIOR TO INT. WALL FRAMING. WINDOWS / DOORS: A. SEE SHT. Al.1 FOR WINDOW TYPES AND DOOR SCHEDULE. B. ALL DOOR AND WINDOW OPENING DIMENSIONS ARE TO ROUGH OPENING, FINISH SUBSTRATES: A. PROVIDE 1/2' THICK MOISTURE RESISTANT GYP. BD. FROM FLOOR SLAB TO 12' A.F.F. MIN. IN LIEU OF GYP. BD,, U,O.N, B. ALL JOINTS, GAPS OR SPACES LEADING TO ALL HOLLOW OR INACCESSIBLE SPACES SHALL BE SEALED WITH 'NSF INTERNATIONAL" APPROVED SEALANTS. C. ALL BACK OF HOUSE AND OFFICE WALLS SHALL HAVE 1/2" CDX PLYWOOD SUBSTRATE, U.O,N. D. PROVIDE SOLID BLOCKING FOR WALL SUPPORTED ITEMS DECOR: A, SEE A2.0 FOR SEATING PLAN AND DETAILS. B. SEE A7.2 FOR FLOOR & CEILING FINISHES. C. SEE A8.0 - A8.3 FOR WALL FINISHES. D, SEE A7.1 FOR CEILING FINISHES, GENERAL: A. PROVIDE THREE FIRE EXTINGUISHERS - (2) 10 Ib, BC and (1),10 Ib. ABC - TO COMPLY WITH LOCAL FIRE CODE, LOCATE PER DIRECTION OF FIRE MARSHALL OR LOCAL AUTHORIZING AGENT, B. DRAWINGS ARE BASED UPON CMU AND UTILIZATION OF METAL STUDS ON NON-BEARING INTERIOR PARTITIONS, BULKHEADS AND SOFFITS. C. ALL ATTACHMENTS MADE THROUGH E.I.F.S. SHALL BE BUSHED TO PREVENT DAMAGE TO THE FINISH, PER 13/A6.2. D. ALL PENETRATIONS THROUGH EJ,F.S. SHALL BE SEALED USING MFR'S, APPROVED METHOD. FLOOR PLAN NOTES I D (_!_/ STARTING POINT, ALL SUB -TRADES SHALL USE THIS POINT AS A BEGINNING LAY -OUT (INSIDE FACE OF EXT. CMU. �� INDICATES 2" DRAINABLE E.LF.S, PIPE BOLLARD, REFER TO SITE DWGS, COORDINATE WITH LOCATION OF GAS METER. D HOOD WALL, SEE WALL LEGEND, . 5 ELECTRICAL MAIN SWITCH BOARD, REFER TO ELECT. DWGS, C� CO2 FILL BOX LOCATION. `_! J METAL THRESHOLD, SPLASH GUARD, SEE DETAIL 7/A6,3, INSTALLATION SHALL BE COORDINATED WITH HAND SINK INSTALLATION. PROVIDE BLOCKING o> WALLS, (D DOWNSPOUT. 10 S.S, CORNER GUARD / WALL CAP, TYP. ALL CORNERS IN BACK -OF -HOUSE FROM REAR WALL TO THE KITCHEN SIDE OF THE SERVICE COUNTER, SEE DETAIL 10/A6,3, ,..,11 ELECT. PANELS IN 6" FURRED OU -r WALL. SEE DETAIL 18/A6.2. 12 SYRUP BUNDLE IN WALL, 13- 8"xB" HORIZONTAL OPENING FOR SYRUP TUBES, COORDINATE WALL PENETRATION WITH COUNTER INSTALLER. SEAL CHASE TO COUNTER. SEE 19/A6.3. Its -101 It , NO F E D C A 14 LIGHTING CONTROL PANEL, SURFACE MOUNTED. REFER TO ELECTRICAL DRAWINGS. 15 CHASE WALL, 16 LOCATION OF VERTICAL TRIM, SEE DETAIL 19/A6,2 AND SHEET A41. FOR INFILL BEHIND P.O.P. PANEL, SEE DETAILS 11/A6,'I, 12/A6.2 AND SHEET A8.0. �✓j PROVIDE HORIZONTAL DOOR SWEEPS AT ALL EXTERIOR DOORS, SEE SHEETAI.1. KEY NOVAS INCORPORATED engineering. architecture *planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 E:Qtrnnnnnan SEAL EDUARDOL,CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 PLOT DATE: 2008 9'-411 R.O. 8 A6.2 b L A6.2 U A 1 ,' SLL\b ,-Jk 14'-0" _ 1V R.O. Kik 'IG -o" RLO. L / )I, 9'-411 lkj R. 0. 0'-0" SLAB O I I "17 1 BUILDING---�I A6.1 I CORNER 14'-0" R. 0. I I 1 A6,1 I 9141 R.O. 16 A6,1 I I I 17 A6.1 141011 R.O. 9'-4" R. 0. 8 A6,2 D U-10%" CMU CONST, I 6'-10Y2' CMU CONST, 4 4 A6.2 A6,2 NOTE: THE OUTSIDE FACE OF FRAME FOR WINDOW TYPES'6' and'7' SHALL FLUSH -OUT WITH THE OUTSIDE FACE EXTERIOR FINISH SYSTEM (CORNER WINDOW ONLY). CV 8'-0" 3'-0' R. 0. co c? 17 A6.1 5 6D 18 A6,1 A6,1 S A6,1 I !_/ A D B D 2 GLASS SCHEDULE �j KICKPLATE THRESHOLD 1" INSULATED GLASS; TYPE GL -3 OPENING FOR P.O.P. NO GLASS 8 A6.1 4'-0%2" 2'-11 X" MISCELLANEOUS 1" INSULATED TEMPERED GLASS; TYPE GL -3 G 1" INSULATED SPANDREL GLASS; TYPE GL -5 1/4" TEMPERED GLASS; TYPE GL -2 Q LEXAN PANEL (AROUND P.O.P.). w NO. DOOR SIZE GRAY HIGH PERFORMANCE TINT. SUPPLIED BY SIGN VENDOR. W r,-- 0 0 1/4" OPAQUE SOLID WHITE SPANDREL, NOTE: STOP SHADING COEFFICIENT SPECIFICATION PER LOCAL CODE REQUIREMENTS, DETAIL LOCATIONS DOOR NOTES DAYTIME VISIBILITY INTO DINING ROOM SHALL BE MAINTAINED. n « ❑ NOTE: J a REFER TO SECTION 08800 OF THE SPECIFICATIONS MANUAL FOR GLAZING I 2 3 TYPES (GL-#). 1 2 3 4 GLAZING TYPES N."r,s, 7 I I "17 1 BUILDING---�I A6.1 I CORNER 14'-0" R. 0. I I 1 A6,1 I 9141 R.O. 16 A6,1 I I I 17 A6.1 141011 R.O. 9'-4" R. 0. 8 A6,2 D U-10%" CMU CONST, I 6'-10Y2' CMU CONST, 4 4 A6.2 A6,2 NOTE: THE OUTSIDE FACE OF FRAME FOR WINDOW TYPES'6' and'7' SHALL FLUSH -OUT WITH THE OUTSIDE FACE EXTERIOR FINISH SYSTEM (CORNER WINDOW ONLY). CV 8'-0" 3'-0' R. 0. co c? 17 A6.1 5 6D 18 A6,1 A6,1 S A6,1 I SEE SCOPE OF WORK SHEETS FOR DRIVE-THRU WINDOW INFORMATION 3'-4" I. 3'-0" 0 3 A6,1 N N 1. DIMENSIONS ON THIS DWG. ARE TO FRAME EDGE, REFER TO SHEETS A1.0 AND A5 SHEETS FOR ROUGH OPENING DIMENSIONS. 2. SEE SCHEDULE FOR GLASS TYPES. 3. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SEC; TIONS FOR ROUGH OPENING DIMENSIONS, 4. ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY G.C, U,O.N, 5. STOREFRONT FRAMES SHALL BE CLEAR ANODIZED (SILVER). DRIVE THRU WINDOW SHALL BE CLEAR ANODIZED. 6. LEXAN PANEL (SEE WINDOW TYPE 1 / THIS SHEET) IS PROVIDED BY THE SIGN VENDOR AND INSTALLED BY G,C, REFER TO GLASS SCHEDULE, NOTE E / THIS SHEET, PREFERRED SUPPLIER INTERIOR DOORS, FRAMES & HARDWARE LOCKNET MIKE MOYNAHAN '100 COURCHELLE DRIVE NICHOLASVILLE, KY 40356 800-887-4307 FAX : 859-887-4958 NOTES N.T.S. REFERENCE NOTES: 1. LAMINATE DOORS 5,6 & 8 AND PAINT FRAMES 5,6 &8. REFER TO FININSH SCHEDULE SHEET A7,2. 2. ALL HARDWARE SHALL BE US32D U,O,N. 3. ALL HM FRAMES SHALL BE 16 GA STEEL U.O.N, 4. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND INSTALLED BY THE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH CONSTRUCTION CORES. ALL PERMANENT CORES SHALL BE KEYED ALIKE, 5, PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER. 6. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY. 7. COMPLETE DOOR, FRAME AND HARDWARE PACKAGE INCLUDING: VISION PANEL (WITH 18 GA, HOLLOW METAL FRAME), CONTINUOUS HINGE, HEAVY DUTY CLOSER, RAIN DRIP, DOOR BOTTOM/ SWEEP, WEATHERSTRIP, KICKPLATE AND PANIC HARDWARE, ORDERED THRU LOCKNET SECURITY DOORS, PART f#DU3670L52VED (1-800-887-4307). 8 "VISION" STOREFRONT DOORS SHALL HAVE BUCKET HANDLES BOTH INTERIOR AND EXTERIOR, FLUSH BOLT ON INACTIVE LEAF, DEAD BOLT ON ACTIVE LEAF, 9. MOUNT KICKPLATE ON PUSH SIDE ONLY. '10. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR : 8.5 LBS EXTERIOR MEASURED AT 90 DEGREES TO THE DOOR AT THE STRIKE EDGE. 11, ADA COMPLIANT ACCESSIBILITY SlCiNAGE, INCLUDE BRAILLE AS REQUIRED BY LOCAL JURISDICTION - (1) MEN; (1) WOMEN 12, RESTROOM SIGN IF REQUIRED. VERIFY LOCAL REQUIREMENTS, 13. FRAMES SHALL BE PAINTED. 14. ENSURE THE DOOR OPENS A MAXIMUM OF 90 DEGREES TO MITIGATE POTENTIAL DAMAGE TO THE TOWER LEG (E.I.F.S.) CORNER. 15. EXTERIOR DOOR PUSH / PULLS TO BE INSTALLED BY THE STOREFRONT WINDOW INSTALLER, 16. PROVIDE BRUSH TYPE DOOR SWEEPS AT ALL EXTERIOR DOOR LOCATIONS. DOOR SWEEPS FINISH TO MATCH DOOR FINISH. SWEEPS SHALL BE PROVIDED BY SEALEZE, PART /AD48CCLA09BL. '1-800-SEALEZE. DOOR _ n DOOR !_/ A D B D 2 LOCKS �j KICKPLATE THRESHOLD 2'-1-1'x/4" 8 A6.1 4'-0%2" 2'-11 X" SEE SCOPE OF WORK SHEETS FOR DRIVE-THRU WINDOW INFORMATION 3'-4" I. 3'-0" 0 3 A6,1 N N 1. DIMENSIONS ON THIS DWG. ARE TO FRAME EDGE, REFER TO SHEETS A1.0 AND A5 SHEETS FOR ROUGH OPENING DIMENSIONS. 2. SEE SCHEDULE FOR GLASS TYPES. 3. REFER TO FLOOR PLAN, ELEVATIONS AND WALL SEC; TIONS FOR ROUGH OPENING DIMENSIONS, 4. ALL STOREFRONT MATERIAL AND GLAZING SHALL BE SUPPLIED AND INSTALLED BY G.C, U,O.N, 5. STOREFRONT FRAMES SHALL BE CLEAR ANODIZED (SILVER). DRIVE THRU WINDOW SHALL BE CLEAR ANODIZED. 6. LEXAN PANEL (SEE WINDOW TYPE 1 / THIS SHEET) IS PROVIDED BY THE SIGN VENDOR AND INSTALLED BY G,C, REFER TO GLASS SCHEDULE, NOTE E / THIS SHEET, PREFERRED SUPPLIER INTERIOR DOORS, FRAMES & HARDWARE LOCKNET MIKE MOYNAHAN '100 COURCHELLE DRIVE NICHOLASVILLE, KY 40356 800-887-4307 FAX : 859-887-4958 NOTES N.T.S. REFERENCE NOTES: 1. LAMINATE DOORS 5,6 & 8 AND PAINT FRAMES 5,6 &8. REFER TO FININSH SCHEDULE SHEET A7,2. 2. ALL HARDWARE SHALL BE US32D U,O,N. 3. ALL HM FRAMES SHALL BE 16 GA STEEL U.O.N, 4. ALL LOCKS SHALL BE FALCON 6 PIN INTERCHANGEABLE CORE SUPPLIED AND INSTALLED BY THE G.C. ALL EXTERIOR LOCKS SHALL BE PROVIDED WITH CONSTRUCTION CORES. ALL PERMANENT CORES SHALL BE KEYED ALIKE, 5, PERMANENT CORES SHALL BE SHIPPED TO THE RESTAURANT GENERAL MANAGER. 6. MOUNT DOOR CLOSERS ON RESTROOM OR KITCHEN SIDE ONLY. 7. COMPLETE DOOR, FRAME AND HARDWARE PACKAGE INCLUDING: VISION PANEL (WITH 18 GA, HOLLOW METAL FRAME), CONTINUOUS HINGE, HEAVY DUTY CLOSER, RAIN DRIP, DOOR BOTTOM/ SWEEP, WEATHERSTRIP, KICKPLATE AND PANIC HARDWARE, ORDERED THRU LOCKNET SECURITY DOORS, PART f#DU3670L52VED (1-800-887-4307). 8 "VISION" STOREFRONT DOORS SHALL HAVE BUCKET HANDLES BOTH INTERIOR AND EXTERIOR, FLUSH BOLT ON INACTIVE LEAF, DEAD BOLT ON ACTIVE LEAF, 9. MOUNT KICKPLATE ON PUSH SIDE ONLY. '10. MAXIMUM DOOR OPERATING PRESSURE: 5 LBS INTERIOR : 8.5 LBS EXTERIOR MEASURED AT 90 DEGREES TO THE DOOR AT THE STRIKE EDGE. 11, ADA COMPLIANT ACCESSIBILITY SlCiNAGE, INCLUDE BRAILLE AS REQUIRED BY LOCAL JURISDICTION - (1) MEN; (1) WOMEN 12, RESTROOM SIGN IF REQUIRED. VERIFY LOCAL REQUIREMENTS, 13. FRAMES SHALL BE PAINTED. 14. ENSURE THE DOOR OPENS A MAXIMUM OF 90 DEGREES TO MITIGATE POTENTIAL DAMAGE TO THE TOWER LEG (E.I.F.S.) CORNER. 15. EXTERIOR DOOR PUSH / PULLS TO BE INSTALLED BY THE STOREFRONT WINDOW INSTALLER, 16. PROVIDE BRUSH TYPE DOOR SWEEPS AT ALL EXTERIOR DOOR LOCATIONS. DOOR SWEEPS FINISH TO MATCH DOOR FINISH. SWEEPS SHALL BE PROVIDED BY SEALEZE, PART /AD48CCLA09BL. '1-800-SEALEZE. DOOR _ n DOOR !_/ BUTTS LOCKS CLOSERS KICKPLATE THRESHOLD DOOR MISCELLANEOUS w NO. DOOR SIZE W r,-- 0 STOP DETAIL LOCATIONS DOOR NOTES n « ❑ rr y J a I 2 3 4 1 2 3 4 5 � 1 2 3 1 2 3 11 1 2 3 4 '1 2 3 '1 2 3 4 5 6 vLL LESS THAN DOOR IW z ' L- WIDTH CV Ll j J0 L w- 0LLJ rr W 3c L 0 f. CC Er -x m 0 f W W J D U 9 ❑ W � o (n CT I,1 j (� Lli G U) U 1 (� Lr 0 � m i f W r-) - D_ i ( of L (J C�) Z �/ U Q III W 1- (..) r� `� - a�- Q 0 U f cV I_1 U J C, ❑ W i- tt 7 (� u� �� a Cn W G - ❑ 0 Gl O ❑ 1 M (� D n c r I c1} () l uJ Cn U rr J U J 0 r w C Z C 0 0 0 O (� � U Cr O Z o L �_ U] Q / 11 >:Ik W U L 0 W v) 0 = T U Z rn r� z ❑ J C1 W r (� r WW W 0 ❑ U) -� C 7 L_ r� W (n W W W rr UJ W G (� Z a) ( ) ( � ❑ ~ Q J Lr ❑ � L l J n Wl L] J W J (� (� W U 0 (, 0 Wl J Y) rr ❑ `� ca cLl O n W CC L - W U) r - n -) r `� i Cn W ~ S J G CC L = C T (� m Q N Q - W 0 ❑ I- C3 CO rr C, F �> (`3 Z co F 1: I-0 # Cc ~ k o 0 G a (n W -� U CL a a W (n U 77 W r S 0 rr u L� � -. W C L z Z i T p z II) r� LC N lf) G) W I- :r W (j) O Cn U ~ D - r✓ U 00- O « U 0 CL - a 0 0 0 � -r 0 co W (r) ! W U) rn W L 0 rn C- ri 0 ❑ � W C v) Lu III uJ Z z_ CV L J ri 0 �r J L <i ! -i (� r O( —' U i U U Lr r rj J (� r `t (n -i 0 f— 1 r ❑ L ��' 0 O (D ❑ r iil m < C) - (� = W ! W a W W - U _ co Y I- w = 2 a Cn Cn J U ❑ _ (n 1 &-0" x 7-0" x '1-3/4" A AL AL X X X X X X X X 12/A6.1 8, 10, 15, 16 2 3'-0" x 7-0" x-1-3/4" B ALX X X X X X X X X 12/A6,1 8, 10, 14, 15, 16 3 3'-0" x 7-0" x 1-3/4" B AL AL X X X X X X X X 12/A6.1 6, 10, 15,16 4 3'-6" x 7'-0" x '1-3/4" C HM HM X X X X X X X X 13/A6.1 'I WAG, I WAG, 1 6, 7, 10, 16 5 3'-0" x U-8" x '1-3/4" D WD HM X X X X X X X I I/A&3 11/A6.3 6, 9, 10, 11, 12, 13 6 3'-0" x 6'-8"x'1-3/4" D WD HM X X X X X X X 11/A6.3 I I/A6,3 6, 9, 10, 11, 12,13 7 NOT USED 8 3'-0" x 6-8" x 1-3/4" F WD HM X X X X X 11/A6.3 I I/A6,3 9'.13 DOOR SCHEDULE 2 w j12 NOTE: ELEVATIONS DRAWN AS VIEWED FROM EXTERIOR OF BUILDING, WINDOW TYPES u4" =1'0"T-9 LEVER 6" 6" SIGN WHERE REQUIRED / C rc) NOT USED _ b \ \ in \ b Ed - 0 !_/ - q B 6'-4" B L A 11 A6.1 — — — — — - /11-8(1 w j12 NOTE: ELEVATIONS DRAWN AS VIEWED FROM EXTERIOR OF BUILDING, WINDOW TYPES u4" =1'0"T-9 LEVER 6" 6" SIGN WHERE REQUIRED / C rc) NOT USED _ b \ \ in \ b Ed - 0 - q f-� FRAME FOR TYPE A&B DOORS SHOWN IN 9/A1,1 INCORPORATED engineering. architecture. planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: ( 305) 558-4124 FAX: (305) 826-0619 E13#0004432 vJ v SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBU SH ARCHITECT -AR 2808 0 A 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA / D D \ _ _ / D Q K-yo7 IL11 noniq j; wimnnw FINISH FLOOR KICKPLATE KICKPLATE E VAT' S ON O N PUSH SID p0NLY O USH SIDE ONLY O O KICKPLATESTOREFRONT AN KITCHEN SIDE STOREFRONT ONLY SYSTEM SYSTEM C m E "L ES NOTE: ELEVATIONS DRAWN AS VIEWED FROM EXTERIOR OF BUILDING OR OUTSIDE ROOM Ai mi ®®®R TYPES 1/4" = 1' U" 3 PLOT DATE: 2008 ul CORE DRILLS A BE MADE FROM APPROVED VEND! TRAWINGS. DO NOT UTILIZE OR -OCATE PER THESE DRAWINGS. 7 I 6 I I 4 I 3 2 I I FOUIPRAFNTIRVATINe., 01 AN Ci QTY. ITEM REMARKS INCLUDES KNEE WALL PLAN VERSION: 0 SITE NUMBER: 297909 STORE NUMBER: < QTY, ITEM REMARKS 2 SERVING COUNTER VI -A9 1 KFC CANVAS COLLAGE ART 36" X 84" SEE A8.0 FOR LOCATION VI -A1 1 KFC CANVAS WALL ART 27" X 52" SEE A8,0 FOR LOCATION 3 4 DINING SCREEN PARTIAL H'F, G3.1 1 KFC ART BUCKET (SET'A') SEE A6.0 FOR LOCATION 4 1 WAITING BENCH G3.2 1 KFC ART BUCKET (SET'A') SEE A8.0 FOR LOCATION O 1 SET TABLE PACKAGE INCLUDES TABLES, FRAMES, BOOTHS [5% (3 SEATS) SHALL BE ACCESSIBLE, G 3,3 1 KFC ART BUCKET (SET'A') SEE A8.0 FOR LOCATION G4,1 1 LADIES SIGN SEE A8.0 FOR LOCATION O 1 SET CHAIR PACKAGE G4.2 1 GENTLEMEN SIGN SEE A8,0 FOR LOCATION �7 1 TRASH RECEPTACLE/TRAY RETURN SINGLE MIA 1 KFC "OMNOVA" ART/WALL PANEL SEE A8.0 FOR LOCATION 0 1 TRASH RECEPTACLE/TRAY RETURN DOUBLE MIB 1 KFC "OMNOVA" ART/WALL PANEL (3 SEGS) SEE A8.0 FOR LOCATION 0 2 WOOD SLAT BENCH C10 1 NUTRITION POSTER * SEE A8.0 FOR LOCATION Gil 1 PLEDGE (ON PLEXIGLASS) SEE A8.0 FOR LOCATION O 1 SET ARTWORK PACKAGE REFER TO PLAN AND SCHEDULE (THIS SHEET) AND INTERIOR ELEVATIONS SHEET A8.0 FOR LOCATIONS 51,1 1 SUNDAY DINNER NEON SIGN SEE A8.0 FOR LOCATION * THE NUTRITION MATERIALS (ACRYLIC HOLDER, NUTRITION POSTER ANDBRAND —] NUTRITION BROCHURES) ARE PART OF A NEW RESTAURANT'S GRAND OPENING KIT AND ARE PROVIDED BY YUM FORMS. SEATING PACKAGE - BY SEATING VENDOR U.O.N. (TOTAL SEATS = 60) E ARTWORK SCHEDULE D DECOR 1. REFER TO SC SHEETS FOR SCOPE OF WORK RESPONSIBILITIES. 2. (H) -SYMBOL DENOTES A HIGH TABLE OR DINING COUNTER WITH STOOLS. 3.HC - SYMBOL DENOTES A HANDICAP ACCESSIBLE TABLE. GENERAL NOTES 0 HOOD FIRE SUPPRESSION SYSTEM (ANSIJL R-102) SPLASH GUARDS. SEE 7A6.3. MAINTAIN 44" MIN CLEAR AISLE EGRESS PATHS TO EXIT DOORS. C 30" x 48" CLEAR FLOOR SPACE FOR HANDICAP ACCESS. 5 DOT INDICATES CORE DRILL LOCATION. CORE DRILL LAYOUT TO BE PROVIDED BY THE SEATING VENDOR. SEE DETAIL 6/A6.3 AND SCOPE OF WORK. �j PULL STATION @ 3'-8" A.F.F. GAS LINE DOWN TO EQUIPMENT. COORDINATE LOCATION OF HORIZ PVC SYRUP CHASE THROUGH WALL TO COUNTER. 9 SEE SHEET At'I FOR SECURITY DOOR PACKAGE, SAUCE DISPENSING+ BRACKET, 111 GAS METER. 1D SWITCHGEAR / ELECTRIC PANELS. KEYNOTES F E D C INCORPORATED engineering. architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 dv SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 3'1914 JACK D. RAUDENBU SH ARCHITECT -AR 2608 A CONTRACT DATE: 10-28-2007 B K -y07 PLAN VERSION: 0 SITE NUMBER: 297909 STORE NUMBER: 0 DRAWING DATE: 0 0 0 A CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA PLOT DATE: 2006 - L EQUIPMENT SCHEDULE NO. QTY G.C. INST. ITEM DESCRIPTION MFR. & MODEL NUMBER PLUMB ELECT GAS REMARKS NO. GAS REMARKS NO. B CONTRACTOR BUILDING ELEMENTS DRAWING DATE: N SINKS/DISHWASHERS B-120 1 X DRIVE-THRU WINDOW QUICKSERV #SC4030CR CLEAR ANODIZED B-120 B-215 1 X WATER HEATER BRADFORD WHITE #EF-100T-199E-3N(A) X X X B-215 B-241 6 X SOAP DISPENSER (WALL MOUNT) KAY 3675 SURFACE MOUNTED B-241 B-251 4 X SANITIZER DISPENSER KAY 3741 SURFACE MOUNTED B-251 B-265 2 X MIRROR, 18" X 36" BOBRICK #B-165-1836 SURFACE MOUNTED B-265 B-275 2 X TOILET PAPER DISPENSER BOBRICK #2890 SURFACE MOUNTED B-275 B-290 4 X PAPER TOWEL DISPENSER BOBRICK #13-262 SURFACE MOUNTED B-290 B-291 2 X PAPER TOWEL DISPENSER / TRASH RECEPTACLE BOBRICK #13-38034 RECESSED B-291 B-300 2 X GRAB BAR 1-1/2"DIA X 36" S.S. FIN. BOBRICK #136806X36 SURFACE MOUNTED B-300 B-305 2 X GRAB BAR 1-1/2"DIA X 42" S.S. FIN. BOBRICK #B6606X42 SURFACE MOUNTED B-305 B-400 2 X WASTE BASKET - 32 GALLON RUBBERMAID #2632 (GREY) B-400 B-405 4 X WASTE BASKET RUBBERMAID SLIM JIM #3541 (GREY) B-405 B-406 I X WASTE BASKET" RUBBERMAID 28 QT #2956 (BLACK) B-406 B-410 '1 X SANITARY NAPKIN RECEPTACLE RUBBERMAID #0140 INCLUDES ACCESSORY KIT & MOUNTING HARDWARE B-410 B-599 1 X MOP SINK STATION ISS #WST806Y B-599 B-620 1 X CHICKEN MOP SINK arATION ISS #MOPCHICKMB B-620 P-001 1 X 60" HEATED DISPLAY UNIT HENNY PENNY #HCW5 X X P-001 C COOKING EQUIPMENT X HEAT SINK TABLE 27"W x 34"H C-001 2 X 8 HEAD PRESSURE FRYER HENNY PENNY 4HP690 X X W/ RACK KIT, ACCESSORY KIT & GAS HOSE KIT #C-503 0-001 C-023 1 X SINGLE OPEN FRYER W/ CONTROLLER PITCO #SGF 18WKS X X COMES WITH GAS HOSE KIT C-023 C-024 1 X DUAL OPEN FRYER W/ CONTROLLER PITCO #SGF18-2WKS X X COMES WITH GAS HOSE KIT C-024 C-025 I X 6 HEAD FRYER PITCO #SG6HNG X X COMES WITH GAS HOSE KIT C-025 C-1130 1 X CONVECTION OVEN W/ CONTROLLER BLODGETT #CTBRAP X C-130 C-183 2 X MICROWAVE OVEN 2100 W SHARP #R-25JT X 0-183 C-198 2 X STAR SPLIT LID TOASTER STAR # GR 14SPTA X FOR C-024 C-198 C-375 I X FRYER LANDING TABLE 24.5" X 36.511 ISS #536FRYACCMBA 0-375 0-503 2 X GAS HOSE KIT 3/4" DO R MONT 'I 675BPOBS48 FOR (2) C-001 C-503 FASTRON #KFCMT300 X P-361 P-460 1 X AIR CURTAIN PASS-THRU WARMER HATCO #FSHAO-2PT X X NO HUMIDITY P-460 P-500 1 X MIXER HOBART #HL200 X P-500 P-532 1 X SHORTENING SHUTTLE WORCESTER SS -709 P-532 P-575 1 X CAN OPENER E EXHAUST HOODS/FIRE SUPP. E-234 1 X KFC HOOD GEN. VENTILATION X SEE HOOD N1FR. DRAWINGS (INCLUDES PRE -PIPING) E-234 AYRKING #BBS-EC1-4830BPC X P -60'I P-650 1 X CONVECTION OVEN TABLE 32"W x 31 "D APW/AMERICAN WYOTT #4857700 P-650 F OFFICE/EMPLOYEE/MUSIC/MISC. X WORK STATION FOR HOT WATER 18"W x 30"D x 76"H F-008 '1 X FILE CABINET (2 DRAWER HIGH) LOUISVILLE MILL - HON R532PL F-008 F-019 '1 X CHAIR - OFFICE HON 5831 F-019 F-025 1 X CHAIR - EMPLOYEE ROOM VIRCO #162 F-025 F-030 1 X COAT HOOKS ISS #HOOK246R2Y F-030 F-036 1 X EMPLOYEE WORKSTATION ISS #WST754E LOCKERS TO BE WALL MOUNTED F-036 F-040 1 OFFICE COMPUTER POS PROVIDED X F-040 F-050 1 CREDIT CARD SATELLITE ROUTER JUNCTION YUM X F-050 F-060 1 BUCKET DISPENSER 46 MONITOR -OFFICE YUM F-060 F-080 1 P-909 OFFICE PRINTER/ COPIER/ FAX/ SCANNER POS PROVIDED X F-080 F-090 1 UPS (IDN-INTERUPTABLE POWER SUPPLY) POS PROVIDED X F-090 F-131 I PLATE HOLDER (4 PACK) MUSIC SYSTEM MUZAK #6848. LOCAL LEASE X MUZAC (LOCAL LEASE), W/ 4 SPEAKERS F-131 F-170 I X SAFE WITH AUDIT LOCK FIREKING #BSD2920AAXRKF X F-170 F-21'1 1 X CLOCK EQUITY TIME #87220 F-211 F-250 I X "RUN A GREAT RESTAURANT" BOARD, 34'W x 40"H B& B SYSTME9 #02010200 F-250 F-270 1 X FIRST AID KIT SWIFT #68-UFPC F-270 F-341 1 X VIDEO TRAINING UNIT WORKSTATION 24"x24" ISS 42424MOT1EA F-341 F-360 1 X VIDEO TRAINING UNIT COBY #TFDVD15911 X MUST ORDER RESTRAINING CABLE F-360 F-506 2 X STACKABLE HIGH CHAIR OLD DOMINION #SI F-506 F-915 3 X FLOOR MAT 3' x 5' ENTRANCE, INC. #41150012 RUBBERIZED F-915 S SERVING/DRIVE-THRU K WORKSTATIONS/SHELVING/CARTS S-002 2 X HEATED CABINET -FULL SIZE R/H HINGE HENNY PENNY #HHC-900 (R/H) X K-130 2 X MOBILE FRONT COUNTER CART 18"X24" ISS #FC18242MYA K-130 K-'13'1 1 X MOBILE CONDIMENT CART ISS #CONDDPSSA K-131 K-198 1 X PREP SINK WORKSTATION 361 ISS #WST756E K-198 K-227 1 X 3 COMP, SINK WORKSTATION, 961 ISS #WST808E K-227 K-269 1 X BREADER WORKSTATION (DOUBLE) '18" x 48" ISS #WST758Y K-269 K-274 1 X BREADING WORKTABLE, 30"D x 24% ISS #WST1141YA K-274 K-280 1 X 48" MICROWAVE WORKSTATION ISS #WST760E K-280 K-281 I X 48" PREP WORKSTATION ISS #WST789E K-281 K-282 1 X MIXER WORKSTATION ISS #WST757E K-282 S-283 5-346 1 X PICK-UP DRIVE-THRU COUNTER (30" x 54") K-300 7 X CHICKEN DOLLY YESS #PE84065 K-300 K-320 1 X SALAD DOLLY APW #21639000 K-320 S-358 8-383 1 X SELF SERVE DRINK COUNTER (47" x 90") K-420 I X CARBONATOR PLATFORM SHELF 18" X 24" ISS #WST34Y K-420 K-425 1 X BAKERS RACK 20.5" x 26" x 69" NEW AGE INDUSTRIAL #1331 K-425 K-437 1 X VEGGIE MODULE, 24" X 36" ISS #WST 1139Y K-437 K-495 1 X SHELVING UNIT 18" x 30" x 74"H (4 TIER) ISS #SU183074Y K-495 K-496 2 X BULKHEAD SHELF 18" x 48" X1 5" ('1 TIER) ISS #BHWS1846Y MOUNTED AT +7'-0" A.F.F. (AT BOTTOM OF LOWER BRACKET) K-496 K-497 6 X SHELVING UNIT 18" x 36" x 74" (4 TIER) ISS #SU 183674Y K-497 K-498 6 X SHELVING UNIT 18" x 48" x 74" (4 TIER) ISS #SU184874Y K-498 K-499 4 X SHELVING UNIT 18" x 60" x 74" (4 TIER) ISS #SU'186074Y K-499 K-502 4 X SHELVING I_JNTT 24" X 36" X 74"H (4 TIER) ISS #SI-J243674Y K-502 K-504 5 X SHELVING UNIT 24" x 48" x 74"H (4 -TIER) ISS #SU244874Y K-504 K-506 3 X SHELVING UNIT 24" x 60" x 74"H (4 "TIER) ISS #SU246074Y K-506 LOCATED ON SHELF BENEATH DRINK MACHINE 3-570 S-580 I CO2 (BULK) TANK MVE #11805373 WITHOUT IMPURITY RING S-580 S-592 1 X WATER FILTER SYSTEM L LIGHTING/SIGNAGE/MENUBOARDS X L-042 I X INTERIOR MENU BOARD PACKAGE, 7 -PANEL POSTERLOID SEE SCOPE OF WORK L-042 L-150 1 X SECURITY DOOR DANGER SIGN ADVERCO#ADVCUSTOM ORDERED DIRECT FROM YRFS L-150 L-'15'1 1 X CHAMPS BOARD 31 "W x 23"H ORDERED DIRECT FROM YRFS L-151 S-813 S-814 'I X 2x3 INFRA RED HOLDING:, UNIT PRINCE CASTLE #DHB2P-F-46KFC X 5-814 S-808 1 X 4x3 HOLDIN(_a CABINET DUKE #FWM34-43KF 1 -208 X EQUIPMENT SCHEDULE NO. QTY C.C. INST. ITEM DESCRIPTION MFR & MODEL NUMBER PLUMB ELECT GAS REMARKS NO. W750279 DRAWING DATE: N SINKS/DISHWASHERS N-0'13 1 X 3 -COMP POWER SOAK 108"R x 34"D METCRAFT #200PSB108R1 P X X W/ T& S B-2466 FAUCET & SPRAY RINSE N-013 N-053 4 X HAND SINK (KITCHEN) AERO #HS -MOD X N-053 N-071 2 X MOP SINK FAUCET T&S #13-2465 X N-071 N-130 1 X 1 COMP. SINK FAUCET T&S FAUCET B-2463 X FOR N-702 N-130 N-131 1 X PRE -RINSE KIT T&S B-2466 X FOR N-014 N-131 N-133 4 X HAND SINK FAUCET T&S FAUCET B -2456-W X SPLASH MOUNTED, FOR N-053 N-'133 N-150 4 X HAND SINK FOOT PEDAL T&S B-0501 X FOR N-053 N-150 N-171 1 X 1 COMP. SINK WASTE DRAIN LEVER AERO #S-20 X 2" TWIST TYPE, FOR N-702 N-171 N-202 2 X MOP SINK 24"X24" FLOOR MOUNT SINK AERO MANUFACTURING CO., INC. #3MP-2121-6 X INCLUDES (2) 24"X36" WALL PANELS N-202 N-702 1 X 1 COMP PREP SINK 381W X 27"D X 35 1/2"H AERO #2F1211618L X N-702 P FOOD PREPARATION P-001 1 X 60" HEATED DISPLAY UNIT HENNY PENNY #HCW5 X X P-001 P-028 1 X HEAT SINK TABLE 27"W x 34"H APW WYOTT #4882300 P-028 P-034 1 X M A,P.S, 60" BASE UNIT 34"H APW WYOTT #K60BU4882825 P-034 P-054 1 X HOTWELL TABLE 34"H APW #K46HS4883500 X X W/ UC STORAGE/OVERSHELF P-054 P-105 1 X POST PACK TABLE 32"W x 52 5"D x 34"H APW WYOTT #K32POST P-105 P-164 1 X COLDWELL TABLE 34"H APV/ #K35.5CS4883525 X X VV/ UC STORAGE/OVERSHELF P-164 P-206 1 X OVERSHELF W/ RACEWAY APW WYOTT #4883550 P-206 P-361 1 X MIXER TIMER FASTRON #KFCMT300 X P-361 P-460 1 X AIR CURTAIN PASS-THRU WARMER HATCO #FSHAO-2PT X X NO HUMIDITY P-460 P-500 1 X MIXER HOBART #HL200 X P-500 P-532 1 X SHORTENING SHUTTLE WORCESTER SS -709 P-532 P-575 1 X CAN OPENER EDLUND G-2 P-575 P-60'1 2 X BREADER (SINGLE) 481 x 30"W x 36"H AYRKING #BBS-EC1-4830BPC X P -60'I P-650 1 X CONVECTION OVEN TABLE 32"W x 31 "D APW/AMERICAN WYOTT #4857700 P-650 P-674 1 X WORK STATION FOR HOT WATER 18"W x 30"D x 76"H ISS #WST790E HOT WATER DISPENSER STATION P-674 P-721 1 X 5 GAL HOT WATER MACHINE BUNN H5X-60-208 X X P-721 P-864 I X STAINLESS STEEL WORK TABLE 30"W x 30"D ISS #WTO3030Y P-864 P-909 2 X BUCKET DISPENSER 46 AJ, ANTUNES #9900342 W/ PREPACK 24" P-909 P-910 2 X BUCKET DISPENSER #8 A.J. ANTUNES #9900346 In// PREPACK 24" P-910 P-911 1 X PLATE HOLDER (4 PACK) APW #4875680 P-911 P-912 1 X ACCESSORY KIT APW #4883575 P-912 R REFRIGERATION R-002 1 X SINGLE SPLIT DOOR FREEZER (LH) TRAULSEN #012001 X 29-7/8"W x 34-15/16"D x 83-1/4"H R-002 R-029 1 X 1/2 HT. FREEZER (LH) STD, CASTERS DELFELD 403CA, LH X W/ WORK TOP R-029 S SERVING/DRIVE-THRU S-002 2 X HEATED CABINET -FULL SIZE R/H HINGE HENNY PENNY #HHC-900 (R/H) X W/ GLASS DOORS ON FRONT AND BACK S-002 S-200 I DRIVE -THRID TIMER ERC #DTT-KFCNT X S-200 5-220 1 X HEADSET HOOKS HME #321006 5-220 S-250 1 DUAL OUTPUT VEHICLE DETECTOR ERC #9172 X 5-250 S-251 1 DRIVE=THRID TIMER DISPLAY UNIT ERC TM -05 X S-251 S-260 1 X DRIVE THRU CONDIMENT TOWER ISS #CONDTOW24LA S-260 S-283 1 X DRIVE THRU DRINK STAGER ISS #WST788E S-283 5-346 1 X PICK-UP DRIVE-THRU COUNTER (30" x 54") IS5 #W5T1140Y S-346 S-358 1 X BEVERAGE COUNTER -DRIVE THRU 7011 x 32"D x 34"H DELFIELD # S-358 8-383 1 X SELF SERVE DRINK COUNTER (47" x 90") CARTER HOFFMANN #(_,H'3- TB590 5-383 S-453 2 X T-SHIRT BAG HOLDER FRANKE #27012973 (ATTACH TO PO`TPACK) 5-453 S-477 2 X DUAL SIDE CIDP DISPENSER A,J. ANTUNES #9900350 S-477 S-482 2 X CUP DISPENSER 30-1/16" x 15-1/16" x 23-3/4"D A.J. ANTUNES #DACS60 S-482 S-512 2 X ICE CUBEB MANITOWOC #SY0674C X X 5-512 S-532 2 BEVERAGE DISPENSER (SELF SERVE/DRIVE THRID) CORNELIUS #ED 250 X X S-532 S-550 1 BAGI-N-BOX SYRUP RACK CORNELIUS/REMCOR BNB12B8P X FLO-3REG-2CRB 5-550 S-570 2 CARBONATOR CORNELIUS/REMCOR X X LOCATED ON SHELF BENEATH DRINK MACHINE 3-570 S-580 I CO2 (BULK) TANK MVE #11805373 WITHOUT IMPURITY RING S-580 S-592 1 X WATER FILTER SYSTEM SELECTO #TB5/620-5 X S-592 S-600 2 X BUNDLED SYRUP LINES CORN ELI US/REMCOR TUBE BUNDLE X SEE SCOPE OF WORK S-600 S-813 1 X 2x2 INFRA RED HOLDING UNIT PRINCE CASTLE #DHB2PT-33KFC X S-813 S-814 'I X 2x3 INFRA RED HOLDING:, UNIT PRINCE CASTLE #DHB2P-F-46KFC X 5-814 S-808 1 X 4x3 HOLDIN(_a CABINET DUKE #FWM34-43KF 1 -208 X S-808 U SECURITY/COMM,/FIRE PROT./POS U-022 1 X CCTV DVR & MONITOR MARTCO, INC, X U-022 U-024 I 1 X BASE STATION - D/T COMM. SYSTEM HME SYSTEM #0113466 IQ SYSTEM X 6 COMMUNICATORS & BATTERY CHARGER, +7'-0" A.F.F. U-024 U-048 1 X 'SECURITY SYSTEM ADT #E53200094 X U-048 U-070 3 RECEIPT PRINTER POS PROVIDED X 2 FOR F/C AND I D/T U-070 U-100 4 POS/ORDER ENTRY TERMINAL POS PROVIDED X U-100 U-121 2 CASH DRAWER HOLDER POS PROVIDED SEE SCOPE OF WORK U-121 U-152 3 =CASH DRAWER POS PROVIDED SEE SCOPE OF WORK U-152 U-197 2 X MONITOR WALL BRACKET POS PROVIDED U-197 U-198 6 X 17" MONITOR (FLAT SCREEN) POS PROVIDED X SEE SCOPE OF WORK U-198 U-199 4 X MONITOR BRACKET POS PROVIDED SEE SCOPE OF WORK U-199 U-250 6 BUMP BAR POS PROVIDED U-250 W WALK-IN COOLERS/FREEZERS W-037 1 X WALK-IN COOLER/FREEZER ICs X X W-042 NOTE: ITEMS NOTED AS "CURRENTLY UNDER A FIELD VALIDATION PROGRAM" ARE PART OF A LARGE SCALE EVALUATION AND MAY NOT BE APPROVED FOR CONITNUING USE FOLLOWING COMPLETION OF THE EVALUATION. PLEASE CONTACT YOUR DISTRIBUTOR IF YOU HAVE ANY QUESTIONS. B DCr CLEARANCE BAR, SECURITY DOOR, WATER HEATER, D%r WINDOW, RESTROOM ACCESSORIES, AIR DOOR/CURTAIN, MOP SINK, HAND SINK ACC., CORNER GUARDS, MATS C FRYERS, OVENS, GRILLS, RETHERMALIZERS, TOASTERS, MICROWAVE E KITCHEN EXHAUST HOOD`;, FIRE SUPPRESSION EQUIPMENT F SAFE, OFFICE EQUIPMENT, EMPLOYEE STORAGE/BREAK K SHELVING, WORKSTATIONS, CARTS, RACKS, DOLLIES L SITE LIGHTING, SIGNAGE, MENUBOARDS N POWERSOAK, KITCHEN HAND SINKS, PREP, SINKS, DISHWASHERS P M,A.P.S. LINES, I -LINES, PACK LINES, BREADERS, MARINATORS, HOT WATER, WORKTABLES, CHEESE MELTERS R REFRIGERATORS AND FREEZERS (NOT WALK-IN) S DRINK SYSTEMS & EQUIP., HEAT CABINETS, STAGERS, WARMERS, SERVING EQUIP„ D/T EQUIP, U SECURITY SYSTEM, LOCKS, CCTV, D/T COMMUNICATIONS/POS SYSTEM, POS EQUIP. W WALK-IN COOLERS/FREEZERS INCORPORATED engineering. architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AP, 2808 0 0 0 0 0 CONTRACT DATE: '10-28-2007 BUILDING -TYPE K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 PLOT DATE: 2008 yll, 21'-4" TO. WALL i II II I II II I II II i IldI 3'-2" 9 III 16 III I � W, 18'-10" T.O. WALL OVERFLOW SCUPPER CALCULATIONS: 1 V-7` 18'-10" T,O. WALL TYP. 14 9 1, MINIMUM SIZE 3 TIMES SIZE OF GRAIN: 3x 12.586 = 37.76 in 2 < CONTROLS 2, MINIMUM SIZE PER FBC '1 107.3 (PLUMBING): 6"0 30i12= 28.269 in 2 3. MINIMUM SIZE PER FBC. FIG. 1616.3 = 30412 13.. AREA PROVIDED: 3 x13 = 39 IN 2 �c ROOF '12 4"0 ROOF DRAIN (AREA= 945.79 S.F.) 4"0 ROOF DRAIN— (AREA= 878.90 S.F.) NOTE: TRIBUTARY AREA INCLUDES FLAT ROOF AREA PLUS HALF VERTICAL AREA OF 4 FF. PARAPET WALL PER SECTION 1106.4 F.B.C.-2004 4"0 AT 1/4 IN/FT 6"0 DOWN r (2,770.48 S.F.) 4"0 AT 1/4 IN/FT INCO. � .?II➢�- 5" AT 1/4 IN/FT TO CATCH BASIN 4"0 ROOF DRAIN (AREA= 945.79 S.F.) 10 ROOF DRAINAGE ISOMETRIC n 22 f YP. 6" .0 TO CATCH BASIN (TRIB. AREA = 2,770.48 S.F.) 23'-'I" 1 1 '-7" —4" x 13" OVERFLOW SCUPPER 4" x 13" OVERFLOW SCUPPER 4" x 13" OVERFLOW SCUPPER (TRIB, AREA = 945.79 S.F.)r — — — — — — (TRIB. AREA = 878.90 S.F.) (TRIB, AREA = 945.79 S.F.) 23'-1 1/4" x 34'-0" + (23'-1 1/4" +3111 + 23'-1 1/4") I I 23'-1 1/4" x 34'-0" + (23'-1 1/4" -h 23-1 1/4") 23'-1 1/4" x 34'4" + (23-1 1/4"+34'+23'-1 1/4") x 4'/ 2 = 945.79 S.F. I 4 I x 41/ 2 = 878.90 S.F. x 4' / 2 = 945,79 S.F. I 18'-1 p•• 16 I '13 TYP. T.O. WALL — I 4"0 AT 1/4 IN/ CoQ \ ��/ 4'0 AT 1/; IN/FT - `� �2� 2� �, 4"0 AT 1/4 IN,/FT 01Y y <p <r� ------ �- ---- ------------ -- - - - - CD - 21 J 21 17� . ......... ......... i TYP. __ 12 O 12 CEF EF 15 — _ — — 2`0 PVC CONDENSATE DRAIN TO ROOF DRAIN TIE TO CATCH A6 0 I F-1 BASIN (TYP. ALL UNITS) tt 5 I� TYP, / I 12 \ — — — \ 7 — — Lu 0- �- / ---N1,LL� "I L�------__ 1- I i it ----.__ Ak '14 I I- — � � � � / — — — RTIJ 2 A6,0 \ / CID Ir 14 L 0- TYP. \ TYP. — — — — — \ -- — — — — V ,-� 12 j I TYP. \ 12 \ I 20 III- - --------------- LL- -- ------ ----- --- __-___ "/ �_ == =- —JJ = �� -_ 13 TYP, 18' 10" 16 I g 114 16 18' 10° T,O, WALL L21W T.O. WALL T.O. WALL 9 8 7 CRICKETS MUST BE LOCATED AT THE EQUIPMENT AS INDICATED. MINIMUM CRICKET SLOPE; 1/2" PER FOOT. 6 WATERPROOFING: A. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED. B. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY BE MADE AS INDICATED ON THE DRAWINGS OR SPECS. SEE SPECIFICATIONS FOR SEALANT SPECS, C. ALL SHEET MTL FLASHING SHALL BE 22 GA MIN. MISCELLANEOUS: A. ROOF PENETRATIONS CLOSER THAN 12" FROM ANOTHER WILL NOT BE ALLOWED. B. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE/ SUPPLY. ROOF INSULATION: A. RIGID BOARD, INSULATION TYPE 3. REFER TO SPECIFICATION SECTION 07210. B. BOARD THICKNESS TO BE DETERMINED BY SITE-SPECIFIC REGIONAL REQUIREMENTS; 1/2" MINIMUM (PER ROOFING SYSTEM STANDARD). ROOFING SYSTEM: A. SINGLE -PLY SYSTEM. REFER TO SPECIFICATIONS SECTION 07523, B. G.C. SHALL COORDINATE ALL INSTALLATION REQUIREMENTS. ALTERNATE ROOFING SYSTEM: A. MODIFIED BITUMEN MEMBRANE SYSTEM. REFER TO SPECIFICATION SECTION 07550. B. G.C. SHALL COORDINATE ALL INSTALLATION REQUIREMENTS. ROOF CRICKETS: A. CRICKETS Co)) ROOFTOP EQUIPMENT SHALL BE FORMED WITH TAPERED INSULATION TO SUCH AN EXTENT AS TO PROVIDE A POSITIVE MIN, 1/2" SLOPE TO THE VALLEY. ROOF PLAN NOTES 1 D 5 4 WATERPROOFING: A. PAINT UNDERSIDE OF PARAPET CAP FLASHING WITH FACTORY BONDED PAINT GRIP OR PRIMER. B. TOP NAILING AT PARAPET CAP FLASHING WILL NOT BE ACCEPTED, C. PENETRATIONS IN ROOFING MEMBRANE AND FLASHING SHALL ONLY BE MADE AS INDICATED ON THE DRAWINGS OR SPECS. D. SEE SPECIFICATIONS FOR SEALANT SPECS. E. ALL SHEET MTL FLASHING SHALL BE 22 GA MIN. MISCELLANEOUS: A. ROOF PENETRATIONS CLOSER THAN '12" FROM ANOTHER WILL NOT BE ALLOWED. B. EXHAUST FANS MIN. 10'-0" AWAY FROM ALL AIR INTAKE/ SUPPLY, C. LOCATE WALK-IN CONDENSERS ON ROOF ONLY IF REQUIRED BY CODE. LL 1 If - - -1 �C:�: fir'---iI 'LL—_—I l 13 L1— u A6.0 7 3 F E D NOTE: ROOF DRANIAGE, INCLUDING OVERFLOW SCUPPERS, HAVE BEEN DESIGNED AND SIZED IN ORDER TO PREVENT ACCUMULATION OF MORE THAN 5" OF WATER ON ANY PORTION OF THE ROOF PER F.B.C. 1616.2 NOTE: ROOF CONDENSER TO BE MOUNTED ON C ENGINEERED ROOF STANDS WITH CLEARANCES EQUAL TO 1/2 THE DIMENSION OF THE SHOTEST SIDE OF UNIT PER F.B.C. 2004—SECTION NOTE: TOP NAILING AT PARAPET WALL CAP FLASHING WILL NOT BE ACCEPTED. — NOTE: ALL ROOFTOP UNITS SHALL BE SECURED TO ROOF AS INDICATED ON SHEET M-3. ALL CONNECTIONS HAVE BEEN DESIGNED TO RESIST DESIGN LOADS AND WIND OF 146 MPH. B DESIGN LOADS: SLAB -ON -GRADE LIVE LOAD 125 PSF. ROOF DEAD LOAD 25 PSF. ROOF LIVE LOAD 30 PSF. ALLOWABLE BEARING 2,500 PSF. BASIC WIND SPEED 146 MPFI, WIND IMPORTANCE FACTOR 1.0 WIND EXPOSURE IV, INTERNAL PRESSURE COEFFICIENT Y 0.18 NET UPLIFT AT ROOF DECK ASCE-7-98 DRAWING DATE: 51.0 PSF. rP 4' OF TRUSS END 24x36 WALK MATS. SEE ROOF SPECS. 37.10 PSF. (1 MID—TRUSS SPAN REFER TO BUILDING ELEVATIONS FOR WINDOWS AND DOOR DESIGN PRESSURES. 20 2 ROOF PLAN GROUP INCORPORATED engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 C)4 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBU SH ARCHITECT -AR 2808 0 O 0 0 0 0 0 A HVAC UNIT. INSTALL PLUMB AND LEVEL. 15 WASTE VENT THRU ROOF. SEE DETAIL 12/A6,0, CONTRACT DATE: 10-28-2007 16 BUILDING TYPE: K -y07 DETAILS '18 ,et 19/A6.0 PLAN VERSION: 2007-D SITE NUMBER: 297909 NOT USED STORE NUMBER: W750279 A DRAWING DATE: 3-11-2008 KEY NOTES KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 HVAC UNIT. INSTALL PLUMB AND LEVEL. 15 WASTE VENT THRU ROOF. SEE DETAIL 12/A6,0, KITCHEN HOOD EXHAUST FAN, SEE SHEETS M3.0 a M31 AND 16 TRANSITION BETWEEN PARAPETS TYPES/ HEIGHTS. DETAILS '18 ,et 19/A6.0 17 PIPE HOOD FOR SATELLITE DISH AND ICE MACHINE CONDENSERS. SEE DETAIL 9/A6.0, RESTROOM EXHAUST FAN VENT PIPE. SEE DETAIL 2/M4.0. 18 NOT USED _ CANOPIES. SEE SCOPE OF WORK. 24x36 WALK MATS. SEE ROOF SPECS. 19 ROOF LADDER. SEE DETAILS 2,4/A6,0. ICE MACHINE CONDENSERS. 20 WATER HEATER INTAKE. SEE DETAIL 20/A6.0 FOR BRACING DETAIL. WALK-IN COOLER / FREEZER CONDENSERS. SEE SCOPE OF WORKSHEET. 21 410 ROOF DRAIN OUTSIDE AIR INTAKE FOR HVAC UNIT, MAINTAIN MIN. 10'-0" SEPARATION FROM 22 WATER PLY BELOW BASE PLY. NO PENETRATIONS BETWEEN DASHED LINES, PLUMBING VENTS, FLUES AND BUILDING EXHAUST, LINE OF KFC PARAPET CAP. SEE DETAILS I, 6/A6.0. 10 PREFERRED LOCATION FOR SATELLITE DISH SLED. SEE SCOPE OF WORK, 111 NOT USED ROOF CRICKET. 13 DURO-LAST FLASHING CAP. SEE DETAIL 5/A6.0. 14 KFC TOWER RETURN LEG. BRACE WALL (COMPOSED OF 2X6 FRAMING) BACK TO KFC TOWER MAIN WALL WITH (2) 3x3 ANGLES, BOLTED TO RETURN LEG WALL AND MAIN WALL (AT TOP AND MIDPOINT OF RETURN LEG). KEY NOTES KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 • I-41 �. T.O. WALL 111011 T.O. WALL T.U. SIGNAGE FRAi` �11 T,41-0— `` O. TRANSOM PNI �./ T.O. LGUVERS . T.U. VVINDUWS / B.U. TRANSOM LIGI T.O. STAB SYMBOL AREA MANUFACTURER COLOR ALTERNATE IVIFR. ALTERNATE COLOR SITE NUMBER: KFC MAIN WALL BENJAMIN MOORE MOOREGARD "HERITAGE RED" #096-25 NO ALTERNATE ALLOWED FOR THIS COLOR U KFC PARAPET BAND, ACCENT COLOR SHERWIN WILLIAMS SW 2123 "KFC WHITE" 3 ACCENT COLOR SHERWIN WILLIAMS SW "HUNTINGTON BEIGE" KFC ACCENT COLOR BENJAMIN MOORE MOORGARD "CLASSIC BURGUNDY" #096-26 NO ALTERNATE ALLOWED FOR THIS COLOR 5 KFC ACCENT COLOR PITTSBURG PAINT PPG 321-6 "CHAPS" ❑6 KFC BLDG. BASE COLOR SHERWIN WILLIAMS SW 7020 " BLACK FOX" aBOLLARDS DOT YELLOW F-81 I DRIVE-THRU TILE DAL -TILE LESLIE S. LIKINS (502) 637-2750 LESLIE.LIKINSnDALTILE.CONI PORCEALTO PORCELAIN TILE #CD85 OSSIDIANA / UNPOLISHED 121lx 12" DRIVE-THRU TILE GROUT HYDROMENT JEANNE ATKINSON BIDS. (248)478-3958 MOBILE: (8,10)459-1009 H'144 MISTY GRAY, UNSANDED SEE SHEETA7.2 FOR MORE CONTACT INFORMATION EXTERIOR FINISH SCHEDULE 1 MISCELLANEOUS A. SEE SHT A1.1 "WINDOW TYPES" FOR WINDOW ELEVATIONS. B. SEE SCOPE OF WORK FOR RESPONSIBILITIES. C. PAINT COLOR SHOWN ARE COLOR REFERENCES ARE FOR THE E.I.F.S. SUPPLIER D. E.I.F.S. SHALL HAVE SATIN FINISH, TYPICAL. SEALERS (REFER TO SPECS): A. SEALANT AT ALL WALL AND ROOF PENETRATIONS. B. SEALANT AT ALL WINDOW AND DOOR FRAMES AT HEAD AND JAMB. DO NOT SEAL SILL @ WINDOWS. EXTERIOR WALL INSULATION: A. EXTERIOR WALL INSULATION SHALL BE INJECTED FOAM FROM EXTERIOR SIDE OF CMU, cid GROUT JOINT. LEGEND: A. VENDOR SCOPE INCLUDES SUPPLY AND INSTALLATION OF AWNINGS, V//ACANOPIES, SIGNAGE AND ARTWORK. B. SPANDREL LOCATIONS. CRITICAL FINISH OPENINGS: A. BUILDING FINISH OPENINGS THAT ARE DESIGNATED AS 11CRITICAL" SHALL BE MAINTAINED TO PROVIDE FOR THE STANDARD INSTALLATION OF STANDARD SIGNAGE/ BUILDING ELEMENTS, REFER TO SHETS A4. IAND A5.1. GENERAL NOTES I F BM'HERITAGE RED', RM 'CLASSIC BURGUNDY', & SW 'BLACK FOX' SHALL RECEIVE A UV PROTECTION FINISH COAT OF SHERWIN-WILLIAMS SHER-CLEAR 1KACRYLIC CLEAR COAT. O E.I.F.S, BASE COAT W/ 20 OZ. HIGH IMPACT MESH (AT TOWER ENTRIES) TO BE APPLIED, WHERE NO"FED, FROM STARTER TRACK TO 7'-0" A.F.F. REFER TO SPECIFICATION MANUAL FOR E.I.F.S. MANUFACTURER'S ASSEMBLY DETAILS. EXTERIOR FINISH NOTE N.T.S. D I 2" DRAINABLE E.15,8, REFER TO SPECIFICATIONS MANUAL FOR E.I.F.S, MANUFACTURER'S ASSEMBLY DETAILS. (2) DRIP EDGE FLASHING. SEE DE'T'AIL 5/A6.0. (a) KFC TOWER CAP/ PARAPET CAP: PAINT COLORS SHALL BE APPLIED TO TOP, BOTTOM AND FACE OF CAP. SEE DETAILS 1, O/A6.0. CANOPY BY SIGN VENDOR. SEE SCOPE OF WORK, BUILDING SIGN BY SIGN VENDOR. SEE SCOPE OF WORK, WALL LIGHTING. HT. AS INDICATED. SEE SHEET E4.0. SYNTHETIC STUCCO OVER CMIJ, REFER TO SPECIFICATIONS MANUAL FOR E.I.F.S. MANUFACTURER'S ASSEMBLY DETAILS. C� HOSE BIB - REFER TO DETAIL 20/A6.2. ALIGN W/ ADJACENT PERPENDICULAR INTERIOR WALL. CO2 FILLER VALVE & COVER. WALK-IN COOLER/FREEZER UNIT, PROVIDED WITH FACTORY FINISH (SEE EXTERIOR FINISH SCHEDULE), SEE SCOPE OF WORK. 11 SWITCHGEAR. (:D,2 -INDICATES ROOF BEYOND. 1 TOWER RETURN LEG. REFER TO KEYNOTE -14/A3.0 FOR ADDITIONAL INFORMATION 1 GAS METER. DO NOT PAINT METER. 15 -.-FEEL BOLLARD. SEE SITE DETAILS, 16 TOP OF RTU IF TRANE IS USED (STANDARD) 17 EXHAUST FANS ON ROOF. RICHT SIDE ELEVATION 1/4"=V-0" 1 g PRE -FINISHED ALUMINUM LOUVERS BY SIGN VENDOR. SEE SCOPE OF WORK, 19 GUTTER, DOWNSPOUTS. - SIZE PER LOCAL REQUIREMENTS. 20 WATER HEATER VENT. SEE DETAIL 2/P6.C. 21 LED LIGHTING. 22 LINE OF PAINT COLOR CHANGE, -rYP. 23 "V" GROOVE IN 21' EIFS ONLY. SEE DETAIL 14/A6 2 24 1" E.I.F.S, AT TOWER RECESS ONLY. 25 WALL TO ROOF FLASHING. SEE DETAIL 15/A6.2, 26 TOP OF RTU IF CARRIER IS USED (NON STANDARD), 27 SURFACE APPLIED TRIM, SEE DETAIL 19/A6.2. �28 BREAKME-FAL - FINISFI'r0 MATCH `� FOREFRONT, SEE DETAILS 15 & '16/A6.1. 29) 42" H SAFETY GUARD RAIL ON ROOF. SEE SHEET A3.0 FOR LOCATION AND DIMENSIONS. 30 ROOF ACCESS LADDER. SEE DETAILS 2, 4/A6.0 31 E.I.F.S, CONTROL JOINT - PER MANUFACTURER'S SPECIFICATIONS. COORDINATE WITH CHANGE IN SUBSTRATE FROM CMU WALL TO WOOD FRAME WALL. 32 OUTSIDE FACE OF WINDOW FRAME and BREAK METAL COLUMN COVER SHALL FLUSH -OUT WITH OUTSIDE FACE OF EXTERIOR FINISH SYSTEM (CORNER WINDOW ONLY). 33 WALL TILE, 34 STAINLESS STEEL CORNER GUARDS, 5 HANDICAP SIGNAGE. 6 UNI STRUT "H11 FRAME. K� GROUP INCORPORATED engineering . architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 8260619 EB#0004432 nke� SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 3'1914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 A CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-'11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y0 7 PLOT DATE: 2008 T.O— ..O WALL 2Y T.O. WALL 18' 101 T,O, WALL T.O. SIGNAGE 9'-4" _ B.O. TRANSO "ih-0'-0" _ FIS' N. FLOOR 18'-10" WALL 14'-0" PANEL Y UVERS Y OIL NOPY ,,NSOM _21'-4" .I-.0. WALL '181-10" T.O. WALL IF 14'-0" 0, TRANSOM PNL`r 9'-4' TRANSOM LIGHT FIN. FL. SEE SHEET A4.0 FOR KEYNOTES. LEFT SIDE ELEVATION I/4" = V-01' I A FRONT ELEVATION 1/4" = P-01' 18'-10" F.O. WALL .0. WALL `P 01-011J \ 3.0., CANOPY )/T (CLEARANCE FIN. FL. REAR ELEVATION 1/4" =1'-0° 1 R INCORPORATED engineering * architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 �Ij6 � SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y0 7 PLOT DATE: 2008 EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 5 A6.0 EL.18'-10" _ _ _ _ TOP OF PARAPET — HORIZONTAL 2x6 BRACING AT ALL ROOF LEVELS AT TOP PLATE AND AT MID -POINT BETWEEN SAID LOCATIONS OR AT PLYWOOD PANEL POINTS (EDGES) SPLICES NOT TO EXCEED 16"c/c (VERT.) 3/4° STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ('K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B,C.. 19/32" APA RATED PLYWOOD SHEATHING 32/15 EXTERIOR EXP, 1 NAILED WITH '10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN,) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN, (TYP,) EL. 12'-0" _ _ _ _ TOP OF BOND BEAM — — — & TRUSS BEARING a, 8'x 16" BOND BEAM WITH 2#7 - CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH J -BOX - COORDINATE WITH VENDOR EL.7'-4" _ _ _ _ B.C. HEADER (M.O.) 8" x 8" CONC, LINTEL WITH 1 #7 CONT. SECURITY DOOR SEE SHEET A2.0. 14 A6.1 �j -0'-0" _ _ _ `Y TOP OF SLAB SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS ROOF SYSTEM -TY P, DURO-L-AST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK, SEE STRUCTURAL FOR DECK SIZE AND LAYOUT, REFER TO SPECIFICATION SECTIONS 07210, 07523. 13 A6.1 z WALL SECTION AT SERVICE DOOR 3/4" EXTEND TRUSS MEMBER (24 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF, TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 1 A6.0 EL, 18'-10" _ _ _ _ TOP OF PARAPET LED LIGHT BAND 17 A6.1 TOP OF TRANSOM 2" ALUMINUM STOREFRONT WITH SPANDREL GLASS EL. 12'-0' _ s TOP OF BOND BEAM r ii & TRUSS BEARING �n FINISH GRADE I n r ALUMINUM SUNSHADE 1, BY SIGN VENDOR (SEE OR AT PLYWOOD PANEL POINTS (EDGES) SCOPE OF WORK) SPLICES NOT TO EXCEED 16"c/c (VERT.) t ✓ ii 3/4" STUCCO FINISH OVER 2 LAYERS TRANSOM LIGHT BY 10-28-2007 K-yQ7 2007-D 297909 W750279 3-11-2008 SIGN VENDOR (SEE SCOPE OF WORK) _A- 19/32" APA RATED PLYWOOD SHEATHING 8" x 8" CONC, LINTEL 32/16 EXTERIOR EXP. 1 NAILED WITH 10d WITH 1 #7 CONT. NAILS AT 6"c/c AT EDGES & INTERMEDIATE STOREFRONT WINDOW SYSYEM NOTE: OUTSIDE FACE OF FRAME FOR CORNER STOREFRONT WINDOW TYPES'U and'T (ONLY) SHALL FLUSH -OUT WITH OUTSIDE FACE OF EXTERIOR FINISH SYSTEM. - SEE HEAD DETAIL 5/A6.2 - SEE JAMB DETAIL 8/A6.2 - SEE SILL DETAIL 4/A6.2 SYNTHETIC STUCCO OVER CMU 0'-0" TOP OF SLAB SEE STRUCT, DWGS. FOR FOUNDATION AND SLAB DETAILS ROOF SYSTEM - TYP,: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK. SEE STRUCTURAL FOR DECK SIZE AND LAYOUT. REFER TO SPECIFICATION SECTIONS 07210, 07523. 6" C!\/IU, SEE STRUCTURAL _ _ _ _ _ _ _ _.EL. 9'-4° B.O. HEADER (M.0.) 18 A6.1 13 A6.3 WALL SECTION AT DINING 3/4" EXTEND TRUSS MEMBER (24 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION EL. 18'-10" _ _ .-0-— — — — —— — TOP OF PARAPET C) EL. 0'-0" _ TOP OF SLAB — — — — HORIZONTAL 24 BRACING AT ALL ROOF FINISH GRADE LEVELS AT TOP PLATE♦. 10" x 16" CONCRETE CURB AND AT MID -POINT BETWEEN SAID LOCATIONS WITH 2 95 CONT, OR AT PLYWOOD PANEL POINTS (EDGES) A SPLICES NOT TO EXCEED 16"c/c (VERT.) FOUNDATION AND SLAB DETAILS 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH 10-28-2007 K-yQ7 2007-D 297909 W750279 3-11-2008 ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F,B.C, 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS CANOPY MOUNTING PLATE BY VENDOR OVERLAP BOND BEAM 8" MIN, (TYP,) CANOPY BY SIGN VENDOR (SEE SCOPE OF WORK) _ _ TOP OF BOND BEAM — — — — — — r, EL. 12'-0' QO TOPOF BOND BEAM CORNER BARS AT EACH CORNER, & TRUSS BEARING BEND 3'-0" EACH LENGTH r, r r - r� r 11 ------------------------------ ---------------- �If1-1---------------- - - i ----------------- EL. 10'-0" _ _ _ ♦� B.O. LINTEL (M.O.) BUILDING'S PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN. (TYP.) SPANDREL GLASS i 6 A6.1 DRIVE-THRU WINDOW PASS-THRU UNIT, SEE SCOPE OF WORK, — EL. 3'-0" _ DRIVE THRU WDVV. M.O. — — _ 10" COORD. W/ CIVIL DWGS. WALL SECTION / DRIVE-THRU AREA L ROOF TRUSS REFER TO STRUCT DWGS. FOR SIZES, LOCATIONS AND PROFILES - 8" x 8' CONC. LINTEL WITH 1 {>E7 CONT. 5 A6,1 SUSPENDED CEILING I Cn 8'-4"A. F. F. 8" X 8 CONC. SILL WITH 2#5 CONT. HORIZONTAL WALL REINF, AT 16"o.c. VERTICAL TYP, OF ALL BLOCK WALLS (9 GA, LADDER TYPE) #6 DOWELS WITH STANDARD HOOK AT 32" o.c. EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION EL. 18'-10" _ _ TOP OF PARAPET — — — A C) EL. 0'-0" _ TOP OF SLAB — — — — O U — — FINISH GRADE LEVELS AT TOP PLATE 10" x 16" CONCRETE CURB AND AT MID -POINT BETWEEN SAID LOCATIONS WITH 2 95 CONT, OR AT PLYWOOD PANEL POINTS (EDGES) A SEE STRUCT. DWGS, FOR FOUNDATION AND SLAB DETAILS 3/4" STUCCO FINISH OVER 2 LAYERS WALL SECTION / DRIVE-THRU AREA L ROOF TRUSS REFER TO STRUCT DWGS. FOR SIZES, LOCATIONS AND PROFILES - 8" x 8' CONC. LINTEL WITH 1 {>E7 CONT. 5 A6,1 SUSPENDED CEILING I Cn 8'-4"A. F. F. 8" X 8 CONC. SILL WITH 2#5 CONT. HORIZONTAL WALL REINF, AT 16"o.c. VERTICAL TYP, OF ALL BLOCK WALLS (9 GA, LADDER TYPE) #6 DOWELS WITH STANDARD HOOK AT 32" o.c. EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION EL. 18'-10" _ _ TOP OF PARAPET — — — A A HORIZONTAL 2x6 BRACING AT ALL ROOF � LEVELS AT TOP PLATE ` AND AT MID -POINT BETWEEN SAID LOCATIONS A OR AT PLYWOOD PANEL POINTS (EDGES) A SPLICES NOT TO EXCEED 16"c/c (VERT.) 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH 10-28-2007 K-yQ7 2007-D 297909 W750279 3-11-2008 ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT 611c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN.) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN, (TYP,) EL, 12' f'I`} _ _ TOP OF BOND BEAM — — — — — — — TRUSS BEARING QO 8' x '16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH 3/4" STUCCO FINISH 8" MASONRY BLOCK HORIZONTAL WALL REINF. AT 16"o.c. VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 5/8" GYPSUM BOARD FI -FOIL B-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN,) PROVIDE DRAFTSTOPS AT CEILING & 8 FT.c/c (MAX.) ALL EXTERIOR WALLS EL. U-0° T,O. SLAB — — — FINISH GRADE — — — — SEE STRUCT, DWGS. FOR FOUNDATION AND SLAB DETAI ROOF SYSTEM - TYP,: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK. SEE STRUCTURAL FOR DECK SIZE AND LAYOUT. REFER "f0 SPECIFICATION SECTIONS 07210, 07523, ROOF TRUSS REFER TO STRUCT. DWGS. SUSPENDED CEILING (WHERE OCCURS) #6 DOWELS AT 32" o,c, (36" LAPS) GROUT CORES SOLID #6 DOWELS WITH STANDARD HOOK AT 32" o.c, NOTE: SECTION NOTES SHALL APPLY TO ALL BUILDING SECTIONS UNLESS NOTED OTHERWISE (U.N.O.). TYPICAL WALL SECTION aid NOTES 3/4" = 1'-0" A G R0 U INCORPORATED engineering. architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 330'14 PHONE: (305) 558-4124 FAX: (305) 826-0619 E B #0004432 �l SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 319'14 JACK D. RAUDENBIJSH ARCHITECT -AR 2808 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 WALL SECTIONS A A A A A A A A CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10-28-2007 K-yQ7 2007-D 297909 W750279 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 WALL SECTIONS EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 8 lU — T,U. PARAPET 3/4" STUCCO FINISH OVER BUILDING PAPER BACKED METAL LATI I BEAM & TRUSS BEARING ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. . 19/32" APA RATED PLYWOOD SHEATHING II 32/16 EXTERIOR EXP. 1 NAILED WITH -loci NAILS AT 6"c/c AT EDGES & INTERMEDIATE 0 SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS C SIGN VENDOR (SEE 6" BATT INSULATION (R-19 MIN.) SCOPE OF WORK).1'1111 8'x 16" BOND BEAM WITH 2#7 1 'B() HEADER (M.O.) CORNER BARS AT EACH CORNER, 8" x 8" CONC. LINTEL BEND 3'-0" EACH LENGTH BUILDING PAPER & METALLATH TO OVERLAP BOND BEAM 8" MINT. ---EIL 12-0— _ TOP OF BOND BEAM CANOPY BY SIGN & TRUSS BEARING ori BY VENDOR, SEE #6 DOWELS' AT 32" o.o. SCOPE OF WORK (36" LAPS) GROUT CORES SOLID 2" E.LF.S, 1" E,I.F.S. WALK IN COOLER / 15 FREEZER (SEE SCOPE A6.2 OF WORK) 100, -__.-_-� -- - -- --.-- --------------- } B0, .G. HEADER (M.U.) -I 8" x 8" CONCRETE LINTEL WITH 1 #7 CUNT. I I I I OPENING �{ i I I I I I SEE STRUCT. DWGS. FOR FOUNDATION AND SLAD DETAILS TOP OF PARAPET BEYOND 3/4" STUCCO FINISH OVER BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. ""PHINGLOCK" FLASHING; AS MANUF. BY "FRY REGLET CORP." OR EQUAL CANT, STRIP ROOFING MEMBRANE 2 1/2" RIGID INSULATION (R-19 MIN.) ROOF TRUSS HEIFER TO STRUCT. DWGS. SUSPENDED CEILING WALL SECTION AT REAR OF BUILDING 3/4" = 11-0" H _L' 2114" , — . — . — �' TOP OF WALL EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET -TRUSS 1 MANUF, TO SUBMIT SHOP A6.0 DRAWINGS FOR APPROVAL PRIOR TO FABRICATION rIIIIIk EL—'18' '10" �' T.O. PLATE -f- 1 ' 11 TYP. A6.0 LED LIGHT BAND 3/4" STUCCO FINISH OVER BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.G. 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT 61'c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS 17 A6,1 2" ALUMINUM STOREFRONT WITH SPANDREL GLASS - 8'x -16" BOND BEAM WITH 2#7 BEAM & TRUSS BEARING CORNER BARS AT EACH CORNER, BEND 3'-D" EACH LENGTH /-6 EL_ 121-011 OF`JBOND BEAM II & TRUSS BEARING ALUMINUM SUN SHADE BY SIGN VENDOR (SEE 0 SCOPE OF WORK) TRANSOM LIGHT BY C SIGN VENDOR (SEE SCOPE OF WORK).1'1111 r� 1 'B() HEADER (M.O.) I� LA— 8" x 8" CONC. LINTEL WITH '1# 7 CONT. ENTRY STOREFRONT T.O, SLAB SEE STRUCT. DWGS, FOR FOUNDATION AND SLAB DETAILS 1 10 ,j A6.1 6" CMU, SEE STRUCTURAL WALL SECTION AT FRONT ENTRY 3/4" =1'-0" T z z Lu 0- Q n z LL r.> F-- /rw1\ TOP OF WALL -f � r LED LIGHT BAND 2" E,I.F.S. OVER WD FRAMING 2 x 6 FRAMING � TOP OF WALL — — 1/4" V -GROOVE DRIP SII rillilk EL. 17'-4" �I q' TOP OF WALL - I IIi171 II II Er r I III 1 .LF.S, BEHIND SIGNAGE ELEMENT 2x4 FRAMING @ 16" o.c, I III BEHIND SIGNAGE, SEE EXTERIOR ELEVATIONS I II SIGNAGE ELEMENT I IIi (SEE SCOPE OF WORK) a I II I III CANOPY MOUNTING; BRACKET I III BY SIGN VENDOR, SEE I III SCOPE OF WORK I III pl I �EL . 121_-011 TOP OF BOND 0 BEAM & TRUSS BEARING 0 0 SLOPE E.I.F.S. % II II 0 �/ 0 ---�1------T- CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10 28 2007 K -y07 2007-D 297909 W750279 3-11-2008 III--------------I--II CANOPY BY SIGN BY VENDOR, SEE SCOPE OF WORK 2" E.LF.S, 1" E,I.F.S. ENTRY STOREFRON-r- TOWER LEG (BEYOND) 12 A6.1 rik EL. 01-011 \ T.O. SLAB SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS CONTINUOUS DBL PLATE W/ A35 CLIP TOP & BOTTOM TO FULL HEIGHT 2X6 STUD BEYOND H3 HORIZ. @ EA. STUD ROOF TRUSS REFER TO STRUCT. DWGS, B.O, HEADER (M.O.) \`- 8" x 8" CONC. LINTEL 20 WITH 1 #7 CONT. A&I HEADER -SEE STRUCTURAL WALL SECTION AT SIDE ENTRY 3/4" = v -(y T F /r-1\ - 21'-4" TO _ . . — - TOP OF V�/ALL -� - - � r LED LIGHT BAND \ Ile 2" E,1.F.S. OVER WD FRAMING 2x6 FRAMING @ 16" o.c. EL: 18'-8" 1 TOP OF WALL li 1/4" V -GROOVE DRIP I I '1" E.I.F.S. BEHIND SIGNAGE ELEMENT I 2x4 FRAMING @ 1 611 O.C. BEHIND SIGNAGE, SEE EXTERIOR ELEVATIONS Lu I SIGNAGE ELEMENT v (SEE SCOPE OF WORK) z II� Q I L) U 8'x '16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, n BEND 3'-0"EACH LENGTH I L EL. TOP OF BOND BEAM &TRUSS BEARING HEADER -SEE STRUCTURAL I SLOPE E.I.F.S, EL. 9'-41' I L B.O. HEADER (M.O.) TRANSOM LIGHT BY SIGIVENJDOR (SEE SCOPE OF WORK) 2" E.I,F,S, -1" E.1,F.S. ENTRY STOREFRONT - TOWER LEG (BEYOND) 8" x 8" CONCRETE SILL WITH 2 IA5 CONT. 1-6 21-811 1 SILL M.O. — 3/4" STUCCO FINISH HORIZONTAL WALL REINF. AT -I Ub.c. VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 8" MASONRY BLOCK 01-0" TOP OF SL -B— SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS CONTINUOUS DBL PLATE W/ A35 CLIP TOP & BOTTOM TO FULL HEIGHT 2X6 STUD BEYOND H3 HORIZ. @ EA, STUD DURA -LAO T ROOFING MEMBRANE OVER RIGID INSULATION ROOF TRUSS REFER TO STRUCT. DWGS. -r - 8" x 8" CONC, LINTEL WITH 1 #7 CONT, 2 A6.1 4 _( A6.1 1 5/8" GYPSUM BOARD FI -FOIL B-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN.) WALL SECTION AT KFC TOWER (FRONT) 31T= E CK� GROUP INCORPORATED engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 626-0619 EB#0004432 o� SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA 0 0 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10 28 2007 K -y07 2007-D 297909 W750279 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA EL. 12-0" — JI TOP -OF BOND BEAM & TRUSS BEARING SLOPE E.I.F.S. I- - - - - - - - - - - - - -i- CANOPY BY SIGN BY VENDOR. SEE SCOPE OF WORK 2" E.I.F.S. 1" E,1.F.S. TOWER LEG (BEYOND) OPENING FOR P.O.P. NO GLASS, GC TO VERIFY REQUIREMENTS WITH SIGN VENDOR I� 1-1/2" METAL FURRING fc7 16" o.c. n- 11 �� 6 A6,0 CONTINUOUS DBL PLATE W/ A35 CLIP TOP & BOTTOM TO FULL HEIGHT 2X6 STUD BEYOND H3 HORIZ, @ EA. STUD 2'-8" \ I SILL HEIGHT (M.O.) — — — � I 12 A6.1 F.O. SLAB SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS ROOF TRUSS REFER TO STRUCT, DWGS. _ EL. Y-41' B.O. HEADER 8" x 8" CONC. LINTEL 20WITH 1 IA7 CONT. A6.1 HEADER -SEE STRUCTURAL WALL SECTION @ P.O.P. PANEL 3/4" = 11-0II EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) 'f0 FORM PARAPET -TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 1 LED LIGHT BAND A6.0 r6 EL. 181-101, rOPOF PARAPET HORIZONTAL 2x6 BRACING AT ALL ROOF \ / LEVELS AT TOP PLATE ♦ / AND AT MID -POINT BETWEEN SAID LOCATIONS 1 -ft - OR AT PLYWOOD PANEL POINTS (EDGES) SPLICES NOT TO EXCEED 16"c/c (VERT.) 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP, 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN.) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN. (TYP.) L. 12'-0" — 'r—TOP OF BOND BEAM & TRUSS BEARING ALUMINUM SUN SHADE BY SIGN VENDOR. (SEE SCOPE OF WORK) 8'x '16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH 3/4' STUCCO FINISH 8" MASONRY BLOCK HORIZONTAL WALL REINF, AT 16"o,c, VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 5/8" GYPSUM BOARD FI -FOIL B-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN.) PROVIDE DRAFTSTOPS AT CEILING & 8 FT.c/c (MAX.) ALL EXTERIOR WALLS ROOF SYSTEM TYP.: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK. SEE STRUCTURAL FOR DECK SIZE AND LAYOUT. REFER TO SPECIFICATION SECTIONS 07210, 07523, r1h EL. 01-01 T.Q. SLAB FINISH GRADE— — SEE STRUCT. DWGS, FOR FOUNDATION AND SLAB DETAILS SUSPENDED CEILING (WHERE OCCURS) #6 DOWELS AT 32" o.c. (36" LAPS) GROUT CORES SOLID #6 DOWELS WITH STANDARD HOOK AT 32" o.c, WALL SECTION AT FRONT 3/4" = 1' o" K EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQ! TIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 1 LED LIGHT BAND --.',". AND A6.0 EL. 18'-10" / �' TOP OF PARAPET I 1 HORIZONTAL 2x6 BRACING AT ALL ROOF LEVELS AT TOP PLATE AND AT MID -POINT BETWEEN SAID LOCATIONS OR AT PLYWOOD PANEL POINTS (EDGES) SPLICES NOT TO EXCEED '16"c/c (VERT.) 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F,B.C, 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP, 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 411c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN.) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN. (TYP.) rilkj EL, '12'-0" _ TOP OF BOND BEAM & TRUSS BEARING ALUMINUM SUN SHADE BY SIGN VENDOR. (SEE SCOPE OF WORK) 8' x 16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH 3/4" STUCCO FINISH 8" MASONRY BLOCK HORIZONTAL WALL REINF, AT 1611b.c. VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 5/8" GYPSUM BOARD FI -FOIL 13-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN,) PROVIDE DRAFTSTOPS AT CEILING & 8 FT.c/c (MAX.) ALL EXTERIOR WALLS 1�- EL . —. . —. . — . — . — . — �-' T.O. SLAB FINISH GRADE_ — SEE STRUCK f. DWGS. FOR FOUNDA'T'ION AND SLAB DETAILS ROOF SYSTEM - TYP.: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK, SEE STRUCTURAL FOR DECK SIZE AND LAYOUT, REFER TO SPECIFICATION SECTIONS 07210, 07523, L ROOF TRUSS REFER TO STRUCT. DWGS. SUSPENDED CEILING (WHERE OCCURS) #6 DOWELS AT 32" o.c. (36'' LAPS) GROUT- CORES SOLID #6 DOWELS WITH STANDARD HOOK AT 32" o,c, WALL SECTION AT SIDE 3/4" =1'-0" J EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF, TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 18'-10' TOP OF PARAPET LED LIGHT BAND 1 A6.0 1 — 3/4" STUCCO FINISH \ / OVER BUILDING PAPER \ / BACKED METAL LATH 3/4" STUCCO FINISH OVER BUILDING PAPER BACKED METAL LATH (''K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C,—r 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS I SIGNAGE ' (SEE SCOPE OF WORK) / k 17 2" ALUMINUM A6.1 STOREFRONT WITH SPANDREL GLASS EL. 12'-01' _ 147T P OF BOND BEAM & TRUSS BEARING 6" x 16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH C411 HEAD HOT. ('M —0,) TRANSOM LIGHT SIGN VENDOR. (S SCOPE OF WORK) STORE -FRONT WINDOW SYSTEM I r L _V BY EE 8" x 8" CONCRETE SILL WITH 2 /A5 CONT. 2' 8" 0`�' SILL HEIGHT (M.O,) 1 E -L—, 2 VA" _ —4— —LED 3/4" STUCCO FINISH IOP OF WALL HORIZONTAL WALL REINF AT 16"o,c, VERTICAL TYP, OF ALL BLOCK WALLS (9 GA, LADDER TYPE) \ 8" MASONRY BLOCK LED LIGHT BAND 0' 0" TOP OF SLAB 2" E,I.F,S, OVER WD FRAMING 2x6FRAMING Cc716"oc. TOP OF WALL 1/4" V -GROOVE DRIP -Ilr i�_ELL 1 / �4; — _ — _ I -fOP I OF WALL I II I 1" E.I.F.S. BEHIND I I� II SIGNAGE ELEMENT 2x4 FRAMING (�-,v 16" o.c. II BEHIND SIGNAGE, SEE EXTERIOR ELEVATIONS SIGNAGE ELEMENT I I� II (SEE SCOPE OF WORK) I Ill II r < CANOPY MOUNTING BRACKET I II i BY SIGN VENDOR, SEE I �� i SCOPE OF WORK I I II < I � i EL. 12-0" — JI TOP -OF BOND BEAM & TRUSS BEARING SLOPE E.I.F.S. I- - - - - - - - - - - - - -i- CANOPY BY SIGN BY VENDOR. SEE SCOPE OF WORK 2" E.I.F.S. 1" E,1.F.S. TOWER LEG (BEYOND) OPENING FOR P.O.P. NO GLASS, GC TO VERIFY REQUIREMENTS WITH SIGN VENDOR I� 1-1/2" METAL FURRING fc7 16" o.c. n- 11 �� 6 A6,0 CONTINUOUS DBL PLATE W/ A35 CLIP TOP & BOTTOM TO FULL HEIGHT 2X6 STUD BEYOND H3 HORIZ, @ EA. STUD 2'-8" \ I SILL HEIGHT (M.O.) — — — � I 12 A6.1 F.O. SLAB SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS ROOF TRUSS REFER TO STRUCT, DWGS. _ EL. Y-41' B.O. HEADER 8" x 8" CONC. LINTEL 20WITH 1 IA7 CONT. A6.1 HEADER -SEE STRUCTURAL WALL SECTION @ P.O.P. PANEL 3/4" = 11-0II EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) 'f0 FORM PARAPET -TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 1 LED LIGHT BAND A6.0 r6 EL. 181-101, rOPOF PARAPET HORIZONTAL 2x6 BRACING AT ALL ROOF \ / LEVELS AT TOP PLATE ♦ / AND AT MID -POINT BETWEEN SAID LOCATIONS 1 -ft - OR AT PLYWOOD PANEL POINTS (EDGES) SPLICES NOT TO EXCEED 16"c/c (VERT.) 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP, 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN.) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN. (TYP.) L. 12'-0" — 'r—TOP OF BOND BEAM & TRUSS BEARING ALUMINUM SUN SHADE BY SIGN VENDOR. (SEE SCOPE OF WORK) 8'x '16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH 3/4' STUCCO FINISH 8" MASONRY BLOCK HORIZONTAL WALL REINF, AT 16"o,c, VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 5/8" GYPSUM BOARD FI -FOIL B-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN.) PROVIDE DRAFTSTOPS AT CEILING & 8 FT.c/c (MAX.) ALL EXTERIOR WALLS ROOF SYSTEM TYP.: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK. SEE STRUCTURAL FOR DECK SIZE AND LAYOUT. REFER TO SPECIFICATION SECTIONS 07210, 07523, r1h EL. 01-01 T.Q. SLAB FINISH GRADE— — SEE STRUCT. DWGS, FOR FOUNDATION AND SLAB DETAILS SUSPENDED CEILING (WHERE OCCURS) #6 DOWELS AT 32" o.c. (36" LAPS) GROUT CORES SOLID #6 DOWELS WITH STANDARD HOOK AT 32" o.c, WALL SECTION AT FRONT 3/4" = 1' o" K EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQ! TIRED) TO FORM PARAPET - TRUSS MANUF. TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 1 LED LIGHT BAND --.',". AND A6.0 EL. 18'-10" / �' TOP OF PARAPET I 1 HORIZONTAL 2x6 BRACING AT ALL ROOF LEVELS AT TOP PLATE AND AT MID -POINT BETWEEN SAID LOCATIONS OR AT PLYWOOD PANEL POINTS (EDGES) SPLICES NOT TO EXCEED '16"c/c (VERT.) 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F,B.C, 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP, 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 411c/c AT PARAPET CORNERS 6" BATT INSULATION (R-19 MIN.) BUILDING PAPER & METAL LATH TO OVERLAP BOND BEAM 8" MIN. (TYP.) rilkj EL, '12'-0" _ TOP OF BOND BEAM & TRUSS BEARING ALUMINUM SUN SHADE BY SIGN VENDOR. (SEE SCOPE OF WORK) 8' x 16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH 3/4" STUCCO FINISH 8" MASONRY BLOCK HORIZONTAL WALL REINF, AT 1611b.c. VERTICAL TYP. OF ALL BLOCK WALLS (9 GA. LADDER TYPE) 5/8" GYPSUM BOARD FI -FOIL 13-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN,) PROVIDE DRAFTSTOPS AT CEILING & 8 FT.c/c (MAX.) ALL EXTERIOR WALLS 1�- EL . —. . —. . — . — . — . — �-' T.O. SLAB FINISH GRADE_ — SEE STRUCK f. DWGS. FOR FOUNDA'T'ION AND SLAB DETAILS ROOF SYSTEM - TYP.: DURO-LAST SINGLE PLY ROOF MEMBRANE OVER RIGID INSULATION BOARDS OVER CORRUGATED METAL DECK, SEE STRUCTURAL FOR DECK SIZE AND LAYOUT, REFER TO SPECIFICATION SECTIONS 07210, 07523, L ROOF TRUSS REFER TO STRUCT. DWGS. SUSPENDED CEILING (WHERE OCCURS) #6 DOWELS AT 32" o.c. (36'' LAPS) GROUT- CORES SOLID #6 DOWELS WITH STANDARD HOOK AT 32" o,c, WALL SECTION AT SIDE 3/4" =1'-0" J EXTEND TRUSS MEMBER (2x6 MIN 2x8 IF REQUIRED) TO FORM PARAPET - TRUSS MANUF, TO SUBMIT SHOP DRAWINGS FOR APPROVAL PRIOR TO FABRICATION 18'-10' TOP OF PARAPET LED LIGHT BAND 1 A6.0 1 — 3/4" STUCCO FINISH \ / OVER BUILDING PAPER \ / BACKED METAL LATH 3/4" STUCCO FINISH OVER BUILDING PAPER BACKED METAL LATH (''K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C,—r 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT 6"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & 4"c/c AT PARAPET CORNERS I SIGNAGE ' (SEE SCOPE OF WORK) / k 17 2" ALUMINUM A6.1 STOREFRONT WITH SPANDREL GLASS EL. 12'-01' _ 147T P OF BOND BEAM & TRUSS BEARING 6" x 16" BOND BEAM WITH 2#7 CORNER BARS AT EACH CORNER, BEND 3'-0" EACH LENGTH C411 HEAD HOT. ('M —0,) TRANSOM LIGHT SIGN VENDOR. (S SCOPE OF WORK) STORE -FRONT WINDOW SYSTEM I r L _V BY EE 8" x 8" CONCRETE SILL WITH 2 /A5 CONT. 2' 8" 0`�' SILL HEIGHT (M.O,) 1 \ 3/4" STUCCO FINISH HORIZONTAL WALL REINF AT 16"o,c, VERTICAL TYP, OF ALL BLOCK WALLS (9 GA, LADDER TYPE) 8" MASONRY BLOCK 0' 0" TOP OF SLAB SEE STRUCT. DWGS. FOR FOUNDATION AND SLAB DETAILS ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C. "SPRINGLOCK` FLASHING AS MANUF. BY "FRY REGLET CORP." OR EQUAL CANT. STRIP ROOFING MEMBRANE 2 1/2" RIGID INSULATION (R-19 MIN.) 6 CMU, SEE STRUCTURAL 8" x 8" CONC. LINTEL WITH 1 #7 CONT. 18 A6.1 5/8" GYPSUM BOARD FI -FOIL B-3 SILVER SHIELD REFLECTIVE INSULATION & RADIANT BARRIER (R-4 MIN.) WALL SECTION @ DINING N.T.S. GROUP INCORPORATED engineering - architecture - planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FA/X: 1305) 826-0619 EB#0004432 l (v� 'J SEAL EDUARDOL,CARCACHE CIVIL ENGINEER -PE 31914 ,JACK D. RAUDENBLJSH ARCHITECT -AR 2808 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-1'1-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -yo 7 WALL SECTIONS 2" DRAINAE E,1.F.S. BOLTS and SPACERS -T E.I.F,S. BY VENDOR (E SCOPE OF SIGN VEND SCOPE OF REFER TO SECTIONS; ELEVATION SIMPSON A34 FRAMING ANCHOR (TOTAL OF 4) 3 - 2x'10 BLOCKING (2) - 2x6 STUDS EACH SIDE OF BLOCKING W/ 2- 12d NAILS INTO EACH OF THE 2x10 BLOCKING MEMBERS >TANDARD CURB BASE, As TEN PER MFR'S iECOMMENDA-I-IONS :LECTRICAL CONDUrr :{ALVANIZED NAILS (c� i" O.C. )CREW THRU NEOPRENE VASHER , 3 PER SIDE 'REFABRICATED CUSTOM 'URB FLASHING 2) TAPERED 2x'12 VVD 'URB OVER 2x >ECURED TU DECK IOOFING MATERIAL NOTE: EXHAUST FAN SHALL BE LEVEL WITHIN 1/8" OVER WIDTH OF CURB `-N HOOD EXHAUST FAN BASE FOR SERVICING/ G. 'ITH APPROVED MATERIAL BRICATED VENTILATED CURB )ION IR FUSED DISCONNECT, " TO HINGED BASE, SEE EL EC. METAL COUNTER FLASHING - TOP & OUTSIDE OF CURB, )ING OVER BASE FLASHING )RICArED GALV, STEEL CURB J LATI ON JOTE: :XHAUST FAN SHALL BE .EVEL WITHIN '1/8" OVER MDTH OF CURB /RAP -SEE MECHANICAL 1vIII, Iv GA. WELUED DUCT EXHAUST FAN CURB N.T.S. 1 S I BUILDING PARAPET 2x2x1/8" ANGLE - LAG BOLT TO PARAPET @ BLK'G & CUT & BEND @ 90° ANGLE PIPE CLAMP -BOL r ,rO ANGLE, TYP, OF 2 HOT WATER INTAKE OR EXHAUST FLUE NOTE: FLUES TO BE SEPARATED BY 18" MIN, EXHAUST TO BE 6" HIGHER THAN I NTAKE, WATER HEATER, FLU SUPPORT N,T.s, 20 X111 611 LADDER PLATFORM TOPS LANDING 3/4 3/8, – 'Cv 0 (2) LADDER UPRIGHTS BAR GUTTER & DOWNSPOUTS SHALL BE SIZED BY LOCAL REQUIREMENTS - MMERCIAL .036 SEAMLESS ALUMINUM BOX GUTTER GUTTER DETAIL 3" =11-0" 113 I HVAC UNIT UNIT OQUNTERFLASHING W/ NEOPRENE PERIMETER GASKET 1" HEAD NAILS AT 6" O.C. MIN, 24 GA. G,I. CAP FLASHING SECURE W/ SCREW THRU rEEL/NEOPRENE WASHER AS NEEDED FOR PROPER SECUREMENT (4 SLUES) 2x8 @ 16"0.C. CD NOTE: SET SUPPORTS ON SOLID NON -RIBBED NEOPRENE, AND SECURE LAG BOLTS THROUGH s rEEUNEOPRENE WASHER KNOCK -DOWN FLAT METAL CURB - SEE SCOPE OF WORK 5/8" PLYWOOD SECURED TO CURB CURB FLASHING TAPERED SLEEPER TO LEVEL CURB ROOFING MATERIAL OVER RIGID INSULATION W/ COVER BOARD NOTE: RTU SHALL BE LEVEL WITHIN 1/8" OVER LENGTH OF EQUIPMENT HVAC CURB 3°=1' o° 14 5/8" CDX PLYWOOD (2)2x12, RIP FOR LEVEL PLATFORM BITUTHENE CAP SHEET OVER TOP OF SLEEPER EXTEND DOWN SIDES BY 211 EASE FLASHING ROOFING MATERIAL ROOFDECK SLEEPER SUPPORT 1 1/2°=1' o° 15 ROOF TOP APPLIANCE EMITTING GREASE SHEET METAL FLASHING- WRAPS TOP & SIDES OF CURB, EXTENDING OVER BASE FLASHING BASE FLASHING ROOFING MEMBRANE ROOFING PROTECTION 1-1/2"=1' o" 16i "/IULTI PIPE GROUPING - 'IPE SLOPING DOWN SWAY FROM SHROUD /LIN. 24 GA. G,I. PIPE :NCLOSURE COVER "HEAD NAIL @6"O.0 )CREW THRU NEOPRENE VASHER 3 PER SIDE �) 2x12 WD CURB OVER 2x )ECURED TO DECK (ASE FLASHING MULTIPLE PIPE FLASHING 1 1/2" =1'-0" S L—JI % % 7 ////////7"- / 111111_L_z Z_ Z_ GC TO PROVIDE SIX (6) ADDITIONAL CEILING GRID WIRE HANGERS C EACH CEILING CLOUD, REFER TO REFLECTED CEILING PLAN SCHEDULED CEILING, TILE (W/-rEGULAR EDGE) NEOPRENE WASHER (FOR TEGULAR TILE OFFSET) UNISTRUT and ALL -THREAD ROD BY ARTWORK VENDOR CEILING CLOUD BY ARTWORK VENDOR CEILING CLOUD ATTACHMENT N.T.s, 1 p (OUTSIDE FACE)>00< _J17 2" DRAINABLE b -- E.I,F.S. -LAST" NATION BAR LLED PER PEC. BREAKMETAL�- NG LAST" NG MEMBRANE--► PLYWOOD HIND "DURO TERM( INSTA MFR. S CONT. FLASHI "DURO- ROOF( '19/3211 SHEAT (INSIDE FACE) 3/4" STUCCO FINISH 19/32" PLYWOOD SHEATHING 2x6 CONT. WOOD BLOCKING TOWER RETURN LEG 3° = 1'-011 11 TALL PIPE OR CLOSED PIPE LINE STAINLESS STEEL BAND PRE -FAB, VENT STACK FLASHING FLASHING ROOFING MATERIAL OVER RIGID INSUL W/ COVER BOARD 2x SOLID BLOCKING STACKED W/ DRILLED HOLE FOR PIPE PENETRATION SEALANT @ PENETRATION SEALED PIPE FLASHING 11/2"=1' 0�12 FIELD PAINTED MIN, 24 GA. GALVANIZED COPING ROLLED BITUTHENE 60 MIL CONT. OVER CANT, ANCHORS WITH NEOPRENE STEEL WASHERS AT 16"o,c. THROUGH VERTICAL SLOTS 1 x WOOD NAILER FIBER CANT DBL. TOP PLATE CONTINUOUS CLEATS WITH #12 x1 1/2" WOOD SCREWS AT 24"o c. 3/4" STUCCO FINISH OVER 2 LAYERS BUILDING PAPER BACKED METAL LATH ("K -LATH" OR EQUAL) INSTALL PER CHAPTER 25 OF THE F.B.C, 19/32" APA RATED PLYWOOD SHEATHING 32/16 EXTERIOR EXP. 1 NAILED WITH 10d NAILS AT F,"c/c AT EDGES & INTERMEDIATE SUPPORTS (FIELD) & PARAPET CAP 311= .11.011 FIBER CANT WELD ,— "DURO-LAST" ROOFING MEMBRANE I CJ 22 GA. GALVANIZED r METAL DRIP EDGE - INSTALLED PER MFR. SPEC, N - 24 GA, ALUM, SOFFIT W/ HEMMED EDGE 611 LED LIGHT BAND 2'' DRAINABLE E.I.F.S. 2x6 WOOD FRAMING_-; (2) 2x4 WOOD BLOCKING KFC TOWER CAP '19/32" PLYWOOD SHEATHING TE, P,T, 2X4 TOWER FRAMING a -- '19/32" PLYWOOD SHEATHING 1" E.I.F.S. (AT TOWER) "DURO-LAST" ROOFING MEMBRANE (1) - H3 SIMPSON u EA, STUD AND (2) - H3 SIMPSON CONNECTIONS AT EACH TOWER STUD. FIBER CANT CONN. @ STUD AND @ BLOCKING 3" =11_x11 FIBER CANT—., r� 22 GA. GALVAN12 METAL DRIP I_ INSTALLED PER 1` SPEC. 24 GA. ALUM, SC W/ HEMMED EDC LED LIGHT BAND 3/4" STUCCO FIN WELD MST16 cc -16" O,C, "DURO-LAST" ROOFING MEMBRANE EXPANSION ANCHORS WITH FLAT WASHER (TYP,) LADDER BRACKET: WELD TO UPRIGHT AT MAX 241- O.C. 4"U.C. VERTICAL SPACING LADDER RUNGS AT T-0" 0.0, VERTICAL SPACING ALUMINUM BAR GRATING LADDER PLATFORM TOP LANDING LADDER FRAME EDGE OF HOOF ALUMINUM BAR GRADING LADDER PLATFORM TOPS LANDING (2) LADDER UPRIGHTS BAR ALUMINUM ANGLE FASTENED TO HORIZ, 2x6 FRAMING .'rcv L �� -- - -I" 0 LADDER RUNG`; AT ------ ED `- SPACING r 'i E - TO UPRIGHTS AT MAX 24" O.C. VERTICAL SPACING 1FR. FFIT O (2) 2x4 E — WOOD 5-1/2" A.1/2" BLOCKING SH a EXPANSION ANCHORS WITH FLAT WASHER (TYP,) LADDER BRACKET: WELD TO UPRIGHT AT MAX 241- O.C. 4"U.C. VERTICAL SPACING LADDER RUNGS AT T-0" 0.0, VERTICAL SPACING ALUMINUM BAR GRATING LADDER PLATFORM TOP LANDING LADDER FRAME EDGE OF HOOF ALUMINUM BAR GRADING LADDER PLATFORM TOPS LANDING (2) LADDER UPRIGHTS BAR ALUMINUM ANGLE FASTENED TO HORIZ, .'rcv L -I" 0 LADDER RUNG`; AT ------ '1 1-0" '1'-0" O.C. VERTICAL `- SPACING r LADDER BRACKETS: WELD TO UPRIGHTS AT MAX 24" O.C. VERTICAL SPACING V KFC PARAPET _CA_ P 3° = 1' o" 1 ifilf6111®YP A VERIFYLOCATIONOF VERTICAL PIPE RAIL 7" MIN. IN FIELD 2 x 2 ALUMINUM ANGLE VERTICAL r PIPE RAIL PIPE RAIL CLAMP, FIELD r WELD / MECHANICALLY "D FASTEN TO LADDER Q FRAN iF > ltflqllw�10I STAINLESS STEEL THRU BOLT WITH FLAT WASHER (TYP,) ---------------� II r — i RAIL BEYOND VERTICAL PIPE RAIL PIPE RAIL r1I AN An VERTICAL PIPE RAIL EXPANSION ANCHORS WITH FLAT WASHER THRU WOOD BLOCKING LADDER AND RAILING NOTES: 1, SUBMIT DRAWINGS AND CALCULATIONS IN COMPLIANCE WITH OSHA STANDARDS 2. MATERIALS: ALUMINUM ALLOY WITH STAINLESS STEEL HARDWARE - GRIND WELDS SMOOTH, 3 RUNGS SHALL BE DESIGNED FOR A SINGLE CONCENTRATED LOAD OF 250 LBS APPLIED IN MIDDLE. RUNGS SHALL BE KNURLED OR PROVIDED WITH A SKID -RESISTANT MATERIAL TO MINIMIZE SLIPPING, 4, LADDER BRACKETS SHALL SUPPORT TWO 250 LB LOADS. 5, RAILING SHALL BE DESIGNED TO SUPPORT A LOAD OF 50 P.LF, APPLIED IN ANY DIRECTION. A TOP RAILING LOAD OF 200 LB IN ANY DIRECTION ON ALL PARTS OF THE QVC -rt NA IC Al Qr) Df7r_)l 11M7 ) r\Ir)T QINZI II TAN4.:ni ic�i v �- R®®F LADDER 111=.11.011 � I INCORPORATED engineering. architecture *planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB -/0004432 U" SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA 2X4 Ff W/ 191 PLYWI I" Ell' SIGNP ELEI`A[ CNIU WALL LIiNTEI HEADI SEE STRU( 2" E.I.F SYNTHETIC STUC( FINISH OVER CMU 19/32" APA RATED PLYWOOD SHEATI PARAPET TRUSS L SHIM AS REQUIRE SEALANT AS REQI SPANDREL GLASS 2" ANODIZED ALUM WINDOW FRAME - WINDOW SCHEDUI SPANDREL GLASS 2" ANODIZED ALUMINUM WINDOW FRAME -SEE WINDOW SCHEDULE, MTL. "Z" FLASHING \All END DAM - NO SEALANT AT FLASHING TO ALLOW WEEPAGE WITHIN FRAME i LINTEL - SEE STRUCTURAL SYNTHETIC STUCCO FINISH OVER CMU I I I LIGHT BOX, --� CONNECTION TO WALL BY SIGN VENDOR --_--- SEALANT AS REQUIRED —� ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE. SILL @ SPANDREL 3 _ V-011 -0 FIB] CANOPY, CONNECTION TO WALLAND SPACERS THROUGH E.I.F.S. BY SIGN VENDOR. G.C. TO COORDINATE CONDUIT PENETRATION OF HEADER and E.I.F.S. (FOR POWER TO CANOPY) WITH STRUCTURAL/ ELECTRICAL. WINDOW HEAD AT ENTRY TOWER 3/16" 0 TA FASTENER MAX. FROP MAX, 16"ch ALONG FI7 INTO CON( SYNTHETIC FINISH OVE SEALANT A SERVICE D( SCHEDULE LINTEL - SEE STRUCT, 20 GA. S.S. WALL GUARD @ HEAD AND JAMBS - ATTACH W/ CONST. ADHESIVE SERVICE DOOR HEAD/JAMB 3"=1'-0" 13 NOTE: SEE FLOOR FINISH PLAN FOR FLOOR FINISHES SERVICE DOOR - SEE DOOR SCHEDULE AND SCOPE OF WORK FINISH FLOOR OVER CONCRETE SLAB ADA COMPLIANT ALUMINUM THRESHOLD -SET IN SEALANT L cV c= PRE -MOLDED EXPANSION JOINT SERVICE DOOR THRESHOLD 3"-1' o" 14 Lr\VI\LI 111�� VVINDUVV FRAME -SEE MATCH WIDTH OF COL. SURROUND BELOW &CAULK WINDOWSCHEDULE. 3 3/16" -£E- - JAMBS @ SPANDREL 3" =1'-0" 15 ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE I 8" x 8" CONCRETE COLUMN REFER TO STRUCTURAL DRAWINGS FOR REINF. 3/16" 0 ''TAPCON" MASONRY 3/4" STUCCO FINISH \L FASTENERS LOCATED 5 3/4" MAX. FROM CORNERS & MAX. 16"c/c ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) JAMBS @ COLUMN 3" = 1'-0" 16 ILEUTT . ..................... ANODIZED ALUMINUM 3/16" 0 "TAPCON" MASONRY WINDOW FRAME - SEE FASTENERS LOCATED 5 3/4" WINDOW SCHEDULE. M.0. MAX. FROM CORNERS MAX. -1 U'c-/c SEALANT AS REQUIRED ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) STUCCO FINISH OVER CMU SHIM AS REQUIRED WINDOW JAMB 3" _ ,' o" 9 FINISH PER SCHEDULE SEALANT A REQUIRED SHIM AS RE ---------- XX----------'J CMU -----Tl , i t n III --------1 LINTEL - SEE STRUCTURAL Ii ---j SYNTHETIC STUCCOXX FINISH OVER CMU �i II - CANOPY, I- E CANOPY, CONNEC"PION I TO WALL BY SIGN VENDOR I ------r--- JJ .. '1 3/4" LANT AS IRED SEA LA DRIVE■THRU WINDOW HEAD CMU 1/2" PLYWOOD is SPANDREL GLASS PANEL 2x6 WOOD ANODIZED ALUMINUM XX> FRAMING WINDOW FRAME - SEE19/32" PLYWOOD WINDOW SCHEDULE SEALANT AS REQUIRED 1>00 2" E.I.F.S. ng < "]IT WINDOW JAMB @ TOWER 3"=V-0" 110 ANODIZED X N r ANODIZED ALUMINUM DOOR - SEE DOOR SCHEDULE PRE -MOLDED EXPANSION JOINT ADA COMPLIANT ALUMINUM THRESHOLD - SET IN SEALANT CONCRETE SLAB STOREFRONT DOOR SILL °=.1 0° 1 2 WINDOW SOLID 3LOCKING DRIVE-THRU WINDOW HEAD 3"=1' 0" 6 ANODIZED ALUMINUM 3/16" 0 "TAPCON" MASONRY WINDOW FRAME -SEE FASTENERS LOCATED 5 3/4" WINDOW SCHEDULE. AA „ MAX, FROM CORNERS & SEALANT AS REQUIRED --7 ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) STUCCO FINISH OVER CMU SHIM AS REQUIRED DRIVE-THRU WINDOW ,JAMB 3"=I o" 7 2x4 FF W/ 119/ PLYWC 1" E,I.F SIGMA ELEME CMU WALL LINTEL SEES] 1 2" E.I.F, ANC WINI MTL. 1/4" SIDE I LIGHT BOX, CONNECTION TO WALL AND SPACERS THROUGH E.I.F.S. BY SIGN VENDOR, G.C. TO COORDINATE CONDUIT PENETRATION OF HEADER and E.I.F.S. (FOR POWER TO LIGHT BOX) WITH STRUCTURAL/ ELECTRICAL. WINDOW HEAD @ FRONT TOWER WINDOW SILL @ SIDELITE ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE— SEALANT AS REQUIRED SHIM AS REQUIRED STUCCO FINISH 8" CONC. SILL 3/16" 0 "TAPCON" MASONRY FASTENERS LOCATED 5,3/4" MAX. FROM CORNERS & MAX. "1611c/c ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) CAULK JOINT SOLID SURFACE SILL 1/2° 1x2 CHAIR RAIL WHERE OCCURS WINDOW SILL @ SYNTH. STUCCO 3"=1'-0" GROUP INCORPORATED engineerinU .architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 3.3014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 P.O,P. PANEL, I I n_\ L� 0 NOT IN G.C. 0 0 SCOPE OF WORK 0 0 CONTRACT DATE: BUILDING, TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10-28-2007 K -y07 2007-D 297909 VV750279 3-11-2008 5/8" GYP BD. 1 'I/2" MTL, STUDS rp 24" ac. U.O.N. LEXAN PANEL BY SIGN VENDOR, SEE SCOPE OF WORK ANODIZED ALUMINUM WINDOW FRAME - SEE L ..............::::;' I WINDOW SCHEDULE { CHAIR RAIL I CMU SILL AT P... ANODIZED X N r ANODIZED ALUMINUM DOOR - SEE DOOR SCHEDULE PRE -MOLDED EXPANSION JOINT ADA COMPLIANT ALUMINUM THRESHOLD - SET IN SEALANT CONCRETE SLAB STOREFRONT DOOR SILL °=.1 0° 1 2 WINDOW SOLID 3LOCKING DRIVE-THRU WINDOW HEAD 3"=1' 0" 6 ANODIZED ALUMINUM 3/16" 0 "TAPCON" MASONRY WINDOW FRAME -SEE FASTENERS LOCATED 5 3/4" WINDOW SCHEDULE. AA „ MAX, FROM CORNERS & SEALANT AS REQUIRED --7 ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) STUCCO FINISH OVER CMU SHIM AS REQUIRED DRIVE-THRU WINDOW ,JAMB 3"=I o" 7 2x4 FF W/ 119/ PLYWC 1" E,I.F SIGMA ELEME CMU WALL LINTEL SEES] 1 2" E.I.F, ANC WINI MTL. 1/4" SIDE I LIGHT BOX, CONNECTION TO WALL AND SPACERS THROUGH E.I.F.S. BY SIGN VENDOR, G.C. TO COORDINATE CONDUIT PENETRATION OF HEADER and E.I.F.S. (FOR POWER TO LIGHT BOX) WITH STRUCTURAL/ ELECTRICAL. WINDOW HEAD @ FRONT TOWER WINDOW SILL @ SIDELITE ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE— SEALANT AS REQUIRED SHIM AS REQUIRED STUCCO FINISH 8" CONC. SILL 3/16" 0 "TAPCON" MASONRY FASTENERS LOCATED 5,3/4" MAX. FROM CORNERS & MAX. "1611c/c ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) CAULK JOINT SOLID SURFACE SILL 1/2° 1x2 CHAIR RAIL WHERE OCCURS WINDOW SILL @ SYNTH. STUCCO 3"=1'-0" GROUP INCORPORATED engineerinU .architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 3.3014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA 0 n_\ L� 0 0 0 0 0 0 CONTRACT DATE: BUILDING, TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10-28-2007 K -y07 2007-D 297909 VV750279 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA 8" CMU WALL 24 @ 22"O.C. FINISH PER PLAN ELECTRICAL PANELS ELECTRICAL PANELS 1.. — .1 �, 1 8 1 STUCCO FINISH FOAM ACCENT BAND FAM ME0Nawat-a1lyj a wam "­'ITHETIC STUCCO SH OVER CMU J STRUCTURE JLK XER ROD ALL AROUND BOX CESSED HOSE BIB BOX. SEE .UMBING FOR SPEC. ALL CLAMP VOID WITH SELF EXPANDING �M AFTER BOX IS INSTALLED :KWRAP OPENINGS BOX IN SEALANT BEAD DOSE BIB 3' _,, 1201 EIFS 71p EXTERIOR SHEATHING= E.I.F.S. WASHER PVC (SCH 40) BUSHING - FILL WIT SEALANT FASTENER AS REQUIRED E.I.F'.S. V -GROOVE 6"=1' o" 1 14 1 2" DRAII PLYWO( 2x6 WO( E.I.F.S. ( MANUF� 6" CMU FINISH SHALL I` DRAINA PLYWOOD SHEATHING E.I.F.S. WASHER BLOCKING AS REQUIRED PVC (SCH 40) BUSHINGl - FILL WITH SEALANT FASTENER AS REQUIRED INSTALL BUSHING AFTER E.I.F,S, APPLICATION HAS HARDENED. DRILL HOLE SLIGHTLY LARGER THAN BUSHING THROUGH INSULATION ONLY, STOP AT PLYWOOD. CAULK OPENING PRIOR TO INSERTING FASTENER TO SEAL PENETRATION, REFER TO SPECIFICATIONS MANUAL FOR E.I.F.S, MANUFACTURER'S ASSEMBLY DETAILS. CONNECTIONS THRID EIFS =1'-o" 13 SPANDREL GLASS 2" ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE.— ------_ MTL. "Z" FLASHING W/ END—\ DAM - NO SEALANT AT FLASHING TO ALLOW = — WEEPAGE WITHIN FRAME LINTEL - SEE STRUCTURAL— STUCCO FINSH LIGHT BOX, CONNECTION TO WALL BY SIGN VENDOR = _ SEALANT AS REQUIRED ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE,— REFER TO DETAILS 4, 8 / A6.2 SILL HEAD @ CORNER WINDOW 3" =1'-0" s I JAMBS "P.O.P." 3" aYPSUM BOARD DVER 3/4" P.T. =URRING MU 2x WOOD =RAMING 19/32" PLYWOOD SASE @ EXT. TOWER WALLS 3" _ .1 0 7 ANODIZED ALUMINUM 3/16" 0 "TAPCON" MASONRY WINDOW FRAME -SEE FASTENERS LOCATED 5 3/4" WINDOW SCHEDULE. M.O. MAX. FROM CORNERS & SITE NUMBER: MAX. 16"c/c SEALANT AS REQUIRED ALONG FIXED RAIL (MIN. 3" DRAWING DATE: INTO CONCRETE) STUCCO FINISH OVER CMU ,HIM AS REQUIRED WINDOW JAMB a'= 1'-0" 13 ANODIZ WINDOV WINDOV STUCCO 8" CMU FINISH: 60 ALCOVE SECTION 1 1/2" =1' o" 12 I STUCCO FINISH BACKER ROD & SEALANT CAULK WEATHER TIGHT J -BOX. MOUNT TO SUPPORTING STRUCTURE, SET IN SEALANT AIR SEAL CONDUIT CMU STRUCTURE J■SOX IN E.I.F.S. OR STUCCO 3" = 1' o" 3 I \I T :FACE "OVE SET =LOOK INCORPORATED engineering • architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 626-0619 EBt,E0004432 _....... J� SEAL EDUARDO L. CACACHE CIVIL ENGINEER -PE 31914 JACK D, RAUDENBU SH ARCHITECT -AR 2808 0 0 0 A 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2006 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 WIN®CfW SILL ®ETAIL 3" = 1'-0° 4, � PLOT DATE: 2UU8 PROTECT SYRUP LINES FROM TRUSS PLATES BUNDLED SYRUP LINES AND FILTERED WATER LINES BOTTOM CHORD OF ROOF TRUSS OPTIONINSTALLATION," AL . I WIDE GALV. STRAPS @ EA. TRUSS (MAX. 6-0" U.C.) NOTE: SEE SCOPE OF WORK FOR SCOPE DEFINITIONS co SYRUP LINE IN CEILING N.T.S. FASTEN 2X BLOCKING TO FACE OF ADJACENT WALL OR TRUSS PLUMBER'S TAPE STRAP 7" DIA. OPENING IN CEILING TILE 6" PVC SECTION VIEV/ SYRUP LINE BUNDLE THRU CLG, SYRUP BUNDLE CLG. PENETRATION N.T.S. WALL SECTION FUD WALL DINING ROOM DRINK COUNTER 4" DIA, PVC CHASE DRIVE-THRU DRINK COUNTER FRAMED OPENING THRID WALL FIN. FLOOR SYRUP CHASE IN WALL N.T,S. 19 -- I/2" GYP, BD. FINISH PER PLAN, I I I 1/2" MOISTURE RESISTANT I GYP, BD. TO 12" A.F.F. FINISH PER PLAN, I I COVE BASE TILE - SET I I FLUSH W/ FLOOR TILE BASE @ DINING ROOM PARTITIONS 3" =1'-o" 20 ANODIZED ALUMINUM WINDOW FRAME - SEE WINDOW SCHEDULE - 3/'16" O "TAPCON" MASONRY FASTENERS LOCATED 5 3/4" MAX. FROM CORNERS & MAX. 16"c/c ALONG FIXED RAIL (MIN. 3" INTO CONCRETE) 7. STUCCO FINISH 8" CMU CAULK JOINT SOLID SURFACE SILL 3/4" Typ CAULK SANITARY COVE BASE TILE - SET FLUSH W/ FLOOR TILE WINDOW SILL DETAIL 3" = v -a" 13 CHAIR RAIL. /—PARGE COAT NOTE: SEE INTERIOR ELEVATIONS FOR FINISHES AND MOUNTING HT, SECTION AT CHAIR RAIL 3" =1' 14 WATER HEATER CORNER GUARD BEYOND FRP TO TERMINATE IN J -MOULD SET IN SILICON SEALANT (NO BASE) PROVIDE SILICONE CHAULK BEAD ALL AROUND WATER HEATER TO SEAL TO THE FLOOR 6" CONCRETE CURB (COLD ,JOINT TO SLAB) COVE BASE WITH SURFACE BULLNOSE FINISHED TILE SURFACE WATER HEATER PLATFORM N.T.S. 15 30ARD OVER NG STRIPS COVE BASE TILE - 1 W/ FLOOR TILE BASE @ DINING ROOM EXT. WALLS 1161 I—■- SAFE - SEE SCOPE OF WORK FOR SCOPE DEFINITIONS 5/8" CEMENT BD. SIZE '1/2" SMALLER THAN SAFE FOOTPRINT. GROUT TO MATCH ADJ. FLOOR, FINISHED CONC. SURFACE ANCHOR BOLTS - SEE SCOPE OF WORK BOLT HOLES = 3/4" DIA x 3" DEEP SAFE PEDESTAL 1-1/2"=1' o" 9 2" 20 GA. S. S. CORNER GUARD -TOP OF BASE TO BOTTOM OF CLG. - ATTACH W/ CONST, ADHESIVE CAULK WALL FINISH OVER SUBSTRATE PER PLAN TILE WHERE OCCURS 20 GA. S.S, END WALL GUARD - "FOP OF BASE TO BOTTOM OF CLG. - ATTACH W/ CONST, ADHESIVE TILE WHERE OCCURS CORNER GUARD 1 0 DOUBLE STUDS AT JAMB AND HEAD WITH ANCHOR STRAP. H.M. FRAME co �. CV Lo H.M. DOOR SEALANT SUBSTRATE AS NOTED ON SHEET A1.0 JAMB @ H.M. DOOR (HEAD SIM.) 30ARD OVER NG STRIPS COVE BASE TILE - 1 W/ FLOOR TILE BASE @ KITCHEN EXT. WALLS 3"=1'-o" 12 47 BOT. OF CLG. LIGHT FIXTURE — (WHERE OCCURS) WALL FINISH OVER 1/2" PLYWOOD _E "FOP HEIGHTS". TOP HGT. = 30"A. F. F. HIGH OP HGT. = 42" A.F.F, JNTER TOP HGT. = 42" A.F.F SUPPORT PLATE SUPPORT 30UT 10CK "FILE TETE SLAB CORE DRILL 1 1/2"=1'-0" s NOTE: CAULK ALL SEAMS AT WALL SURFACE, I I I I I I I I I I I I I . I I • I I (4) #12 S,S. WOOD SCREWS 3/4" LG. W/ S.S. WASHERS, 1/2" HAD. EASED CORNER (TYP.) EXTEND FRONT OF PANEL TO FRONT EDGE OF ADJ. SINK. APPROX. 24" (SEE PLAN) 16 GA. BRUSHED STAINLESS STEEL. '1/2" HEM ON TOP, FRONT AND BOTTOM EDGES. BOTTOM EDGE OF SPLASH GUARD SHALL BE EVEN W/ THE EDGE OF THE HIGHEST ADJ, SINK, NATIONAL GYPSUM - 5/8" HI -IMPACT BRAND XP WALLBOARD. TYPE X CORE. NO SUBsTiTUTIONS ALLOWED. WALL TILE SANITARY COVE BASE TILE - SET FLUSH W/ FLOOR 'FILE PTO - - p Tk M��n L. —I I+ +I L ±I 3 5/8" MTL. BRACE 16" O.C. TO t f / STRIJC, ABOVE / 6" MTL, JOISTS LTJ 15" O.C. MENU BOARD & MOUNTING BRACKET I + ` FURNISHED BY OWNER / INSTALLED BY GC 6 MTL. STUDS Ca)16" 0,C. FRP OVER 1/2" PLYWOOD I -6 e -4 BOIi". OF KITCHEN CLG. 8-0" B'OT. OF SOFFIT FRP OVER PLYWOOD MENU BOARD SECTION 3/4" = V-0" FEND FRP BEYOND G. GRID ILING TILE & GRID BLOCKING o CLG. IP IBSTRATE PER PLAN KITCHEN FINISH CEILING =1'0" 2 I I -�--- FRP D — 1/2° CDX PLYWOOD - PROVIDE '1/4" GAP BETWEEN SUBSTRATE & mois,rURE RESISTANT GYP, BD. I 0 BELOW. 0 1/2" MOISTURE RESISTANT D GYP. BD. TO 12" A.F,F, CONTRACT DATE: BUILDING TYPE PLAN VERSION: 81 -FE NUMBER: STORE NUMBER: DRAWING DATE: FINISH PER PLAN, II --� J MOLD SE'r IN SILICON SEALANT - FILL J -MOLD W/ SILICON PRIOR TO INSTALLING FRP, WIPE OFF EXCESS SANITARY COVE BASE TILE - SEI" FLUSH W/ FLOOR "FILE BASE KITCHEN PARTITIONS — HEAVY DUTY DUAL TRACK WALL STANDARDS Ccs 16" O.C. SECURED TO WALL AT STUD LOCATIONS PER MFR.'S SPECIFICATIONS 12" DEEP, WHITE MELAMINE SHELVING SECURED TO 11.5" HEAVY DUTY DUAL TRACK BRACKETS PER MFR.'S SPECIFICATIONS. OLT, STUD & ANGLE 1x4 SPLASH W/ P. LAM TO MATCH 2-1/4" 21_0.1 COUNTERTOP, 1-3/4" SOLID CORE DOOR COUNTERTOP WITH LAMINATE PER SHEET A8,1 ON TOP AND FRONT EDGE. MITRE & GRIND SHARP EDGES/ 1-21/4 1 POINTS u. \\- I 7 3/4" 2 x 2 x ,a" ANGLE FRAME, TYP. OF (4). Q �? SEE PLAN A/A8.1 FOR LOCATIONS N N I (4) 1/4" O x 1-1/2" LAG BOLTS @ EA, ANGLE BRACKET 1x4 LEDGER W/ P, LAM TO MATCH COUNTERTOP. 1/2" O THRID BOL"F, ` BRACKET AT U.C. KEYBOARD TRAY LOCATION SHALL BE HELD AT 1'-0" FROM EDGE OF COUNTERTOP. OFFICE COUNTER 3/4"=1'-0" 4 INCORPORATED engineering . architecture . planning 15500 NEW BARN ROAD SUITE '1 U6 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FA>C: (305) 826-0619 EB#0004432 20 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D, RAUDENBUSH ARCHITECT -AR 2808 i KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA D 0 0 D CONTRACT DATE: BUILDING TYPE PLAN VERSION: 81 -FE NUMBER: STORE NUMBER: DRAWING DATE: 10-28-2007 K -y07 2007-D 297909 W750279 3-11-2008 i KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA I PANEL WALL FOOD GRADE HTV SEALANT 1 1/4" TEK SCHEU INTERIOR BASE COVE TRIM THINSET TILE ��- - GROUT HIT FASTENER SCREED - 4 n DYNATROL SEALANT n CONCRETE PAD a WALK-IN TILE/BASE 1-1/2" = V-0" I E I 6 A. = DENOTES FINISH MATERIAL. REFER TO SHT A7.2 FOR FINISHES. B. TILE JOINTS (U, 0.N.): 1. QUARRY FLOOR TILE: 1/4" 2. GLAZED WALL TILE : 1/8" 3. BASE, TRIM AND ACCESSORIES: MATCH ADJOINING TILE UNITS C. TILE INSTALLATIONS REQUIRE MANUFACTURERS STANDARD MOLDED CORNERS AT BOTH INSIDE AND OUTSIDE CORNERS, AND BULLNOSE AT TOP OF TILE WAINSCOT (RESTROOM WALL). D. ALL BASE TILE SHALL BE SANITARY COVE STYLE WITH 3/8" MIN RADIUS, U.O.N. E. SEE SCOPE OF WORK FOR RESPONSIBILITIES. F. PROVIDE CLEAR SILICONE CAULK WHERE FRP STOPS A'T TOP OF COVE BASE. G. TILE CHIPPING AROUND CORE DRILL HOLES FOR SEATING WILL NOT BE ACCEPTED. FINISH NOTES I D 4 6" SANITARY COVE TILE BASE (BACK OF HOUSE), SEE DETAILS &I PROVIDE FLOOR TILE INSIDE WALK-IN COOLER & STORAGE. FLOAT FLOOR TILE IN COOLERS TO DRAIN TO KITCHEN. COORD. WITH WALK-IN WALL CONFIGURATION. (___.) PLATFORM FOR SAFE, -SEE DETAIL WA6.3, �44D FLOOR TILE SHALL TRANSITION AT SERVICE COUNTER WALL START POINT FOR FLOOR TILE, METAL BASE IN COOLER; SEE SCOPE OF WORK AND DETAIL E, THIS SHEET, REFER TO STRUCT DRAWINGS FOR CONC FLOOR SLOPES AROUND FLOOR DRAINS. FLOAT FLOOR TILE TO MEET COOLER & STORAGE FLOORS FLUSH. COORD WITH COOLER & STORAGE THRESHOLD INSTALLATION. SANITARY COVE TILE BASE (REs TROOMS). SEE DETAIL 8/A6.3 FOR INSTALLATION. 10� FACTORY FLOOR FINISH (GALV. STL.) W/ INTEGRAL COVE BASE AND BUILT-IN INT, RAMP IN WALK-IN FREEZER. (7t1) DIMENSION STRING REPRESENTS LINE OF FLOOR TILE TRANSITION. (—I6" (-.OVE "FILE BASE (DINING ROOM). SEE DETAILS 16, 20/A6,3 FOR INSTALLATION. x.'13 OMIT TILE AND BASE AT MOP SINK LOCATIONS. 14 CONCRETE WATER HEATER PLATFORM, SEE DETAIL 15/A6,3. TRANSITION FROM KITCHEN TILE T WALK-IN TILE AND FREEZER RAMP MUST BE FLUSH I E FLOOR FINISH PLAN 1/4'=1-0" KEY NOTES FI E a C 0 A INCORPORATED engineering. architecture . planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES , FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB%E0004432 (014 610� SEAL EDUARDOL CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 PLOT DATE: 2008 ............................................................................. I .10 V-0" x 4-0" FLUORESCENT LIGHT FIXTURE 2'-0" x 4'-0" FLUORESCENT LIGHT _ FIXTURE DOWNLIGHT @ WALK-IN (BY WALK-IN MFR.) SUSPENDED PENDENT AT OPEN TRUSS O PENDANT FIXTURE O DOWNLIGHT PENDANT OR DIRECTIONAL FIXTURE, TRACK MOUNTED I EXTERIOR WALL FIXTURE SPEAKER 12" EXHAUST FAN HVAC RETURN GRILLE HVAC SUPPLY DIFFUSER HVAC SUPPLY DIFFUSER HVAC PERFORATED SUPPLY DIFFUSER BACK DOOR SECURITY STROBE LIGHT CEILING SYMBOL LEGEND I E ................................ --- --- ---- ---- --- ---- ---- --- -- - ............._ . - - _ _....-..............._ ..__l 7 6 DIMENSIONS: A. ALL DIMENSIONS ARE TO FACE OF FINISH AND � OF FIXTURES U,0,N. CEILING FINISHES: A. REFER TO ROOM FINISH SCHEDULE (SHTA7.2) FOR CLG. FINISHES. SUSPENDED CEILING: A. ACOUSTICAL PANEL INSTALLATION: INSTALL ACOUSTICAL PANELS WITH EDGES IN CLOSE CONTACT WITH METAL SUPPORTS AND IN TRUE ALIGNMENT. B. ALLOWABLE VARIATIONS FROM FLAT AND LEVEL SURFACE: 1/8" IN 10'-0" MAX. C. ALLOWABLE VARIATIONS FROM PLUMB OF GRID MEMBERS: AS CAUSED BY ECCENTRIC LOADS, 2' MAX. D. INSTALL SYSTEM AFTER MAJOR ABOVE CLG. WORK IS COMPLETE. COORD LOCATIONS OF HANGERS WITH RELATED WORK. E. SEE SPECS FOR ADDITIONAL INFORMATION. GYPSUM BOARD CEILING: A. SUBSTRATE SHALL BE 1/2" THICK GYP BD ELECTRICAL: A. SEE ELECT, DWGS. FOR FIXTURE SCHED. GENERAL NOTES: A. PROVIDE ESCUTCHEON PLATES AND SEALANT AT ALL PENETRATIONS INTO WALLS, CEILINGS, AND FLOORS, DO NOT USE CAULKS OR EXPANDING FOAM FOR SEALANT. REFLECTED CEILING PLAN NOTES D CEILING GRID STARTING POINT. WALK IN COOLER BULKHEAD AT NON -INSULATED BUNDLED SYRUP LINES FOR DRINK SYSTEM, SEE DETAIL 17/A6,3. ALSO SEE SCOPE OF WORK, C7D 6" DIA PVC STUB THROUGH CEILING, SEE DETAIL 18/A6,3. 5 HOOD, FOR ROUGH FRAMING OPENINGS SEE AIR DEVICE SCHED. (TYP. AT RE TROOMS), �D AWNINGS & CANOPIES. SEE SCOPE OF WORK BOTTOM OF BULKHEAD @ 8'-0" A.F.F. 1/2" GYP. BD, OVER 2x6 FRAMING_, - REFER TO 1/A6.3 FOR SIMILAR ASSEMBLY DETAILS. `::9:�) MENU BOARD, SEE SCOPE OF WORK. 10 BOTTOM OF MENU BOARD BULKHEAD @ 8'-0" A.F.F. SEE DETAIL 1/A6.3. 1� BOTTOM OF BULKHEAD @ T-0" SPEAKER, (_„13 PENDANT LTG - CENTER OVER TABLE TOP (TYP). .� EXTERIOR WALL LIGHT FIXTURES, SEE ELEVATIONS AND ELECT. DV/G_",S, l KFC "CLOUD" BY ARTWORK VENDOR, SEE SCOPE OF WORK, REFER TO 10/AG.0 FOR MOUNTING INFORMATION, REFLECTED CEILING PLAN 1/4"=1'-0° (E6) EMERGENCY DUAL HEAD FIXTURE, SEE ELECT, DWGS, 17 SECURITY STROBE LIGHT, SEE ELECT. DWGS. 16� FAN COIL. 19' 6” X 6" STAINLESS STEEL CHASE ALONG WALL FOR ICE MACHINE REFRIGERANT LINES: CEILING TO TOP OF ICE MACHINE, 20 PUB SIGN. SEE ELECTRICAL SHEETS. CASE CEILING PENETRATIONS FOR A CLEAN INSTALLATION. 21 CEILING DIFFUSER (TYP.). SEE MECHANICAL 22 PAINT DUCTWORK, SEE ELEVATION 8/A8.0, KITCHEN WALL FINISH C, CEILING_-,, SEE DETAIL 2/A6.3. 4 M.A.P.S, LINE VERTICAL CHASE THRU CEILING, WALL R.A, DIFFUSER SEE MECHANICAL, SEE ELEVATION 6/A8.0, KEY NOTES F E m C 0 0 INCORPORATED engineering . architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA .33014 PHONE: ( 305) 558-4124 FAX: (305) 626-0619 E B#0004432 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBIJSH ARCHITECT -AR 2808 O IL CONTRACT DATE: EMERGENCY LIGHTS (� EXIT LIGHT PLAN VERSION: (WALL MOUNTED) SITE NUMBER: EXIT LIGHT STORE NUMBER: (CEILING M(-.)[JNTED) PENDANT OR DIRECTIONAL FIXTURE, TRACK MOUNTED I EXTERIOR WALL FIXTURE SPEAKER 12" EXHAUST FAN HVAC RETURN GRILLE HVAC SUPPLY DIFFUSER HVAC SUPPLY DIFFUSER HVAC PERFORATED SUPPLY DIFFUSER BACK DOOR SECURITY STROBE LIGHT CEILING SYMBOL LEGEND I E ................................ --- --- ---- ---- --- ---- ---- --- -- - ............._ . - - _ _....-..............._ ..__l 7 6 DIMENSIONS: A. ALL DIMENSIONS ARE TO FACE OF FINISH AND � OF FIXTURES U,0,N. CEILING FINISHES: A. REFER TO ROOM FINISH SCHEDULE (SHTA7.2) FOR CLG. FINISHES. SUSPENDED CEILING: A. ACOUSTICAL PANEL INSTALLATION: INSTALL ACOUSTICAL PANELS WITH EDGES IN CLOSE CONTACT WITH METAL SUPPORTS AND IN TRUE ALIGNMENT. B. ALLOWABLE VARIATIONS FROM FLAT AND LEVEL SURFACE: 1/8" IN 10'-0" MAX. C. ALLOWABLE VARIATIONS FROM PLUMB OF GRID MEMBERS: AS CAUSED BY ECCENTRIC LOADS, 2' MAX. D. INSTALL SYSTEM AFTER MAJOR ABOVE CLG. WORK IS COMPLETE. COORD LOCATIONS OF HANGERS WITH RELATED WORK. E. SEE SPECS FOR ADDITIONAL INFORMATION. GYPSUM BOARD CEILING: A. SUBSTRATE SHALL BE 1/2" THICK GYP BD ELECTRICAL: A. SEE ELECT, DWGS. FOR FIXTURE SCHED. GENERAL NOTES: A. PROVIDE ESCUTCHEON PLATES AND SEALANT AT ALL PENETRATIONS INTO WALLS, CEILINGS, AND FLOORS, DO NOT USE CAULKS OR EXPANDING FOAM FOR SEALANT. REFLECTED CEILING PLAN NOTES D CEILING GRID STARTING POINT. WALK IN COOLER BULKHEAD AT NON -INSULATED BUNDLED SYRUP LINES FOR DRINK SYSTEM, SEE DETAIL 17/A6,3. ALSO SEE SCOPE OF WORK, C7D 6" DIA PVC STUB THROUGH CEILING, SEE DETAIL 18/A6,3. 5 HOOD, FOR ROUGH FRAMING OPENINGS SEE AIR DEVICE SCHED. (TYP. AT RE TROOMS), �D AWNINGS & CANOPIES. SEE SCOPE OF WORK BOTTOM OF BULKHEAD @ 8'-0" A.F.F. 1/2" GYP. BD, OVER 2x6 FRAMING_, - REFER TO 1/A6.3 FOR SIMILAR ASSEMBLY DETAILS. `::9:�) MENU BOARD, SEE SCOPE OF WORK. 10 BOTTOM OF MENU BOARD BULKHEAD @ 8'-0" A.F.F. SEE DETAIL 1/A6.3. 1� BOTTOM OF BULKHEAD @ T-0" SPEAKER, (_„13 PENDANT LTG - CENTER OVER TABLE TOP (TYP). .� EXTERIOR WALL LIGHT FIXTURES, SEE ELEVATIONS AND ELECT. DV/G_",S, l KFC "CLOUD" BY ARTWORK VENDOR, SEE SCOPE OF WORK, REFER TO 10/AG.0 FOR MOUNTING INFORMATION, REFLECTED CEILING PLAN 1/4"=1'-0° (E6) EMERGENCY DUAL HEAD FIXTURE, SEE ELECT, DWGS, 17 SECURITY STROBE LIGHT, SEE ELECT. DWGS. 16� FAN COIL. 19' 6” X 6" STAINLESS STEEL CHASE ALONG WALL FOR ICE MACHINE REFRIGERANT LINES: CEILING TO TOP OF ICE MACHINE, 20 PUB SIGN. SEE ELECTRICAL SHEETS. CASE CEILING PENETRATIONS FOR A CLEAN INSTALLATION. 21 CEILING DIFFUSER (TYP.). SEE MECHANICAL 22 PAINT DUCTWORK, SEE ELEVATION 8/A8.0, KITCHEN WALL FINISH C, CEILING_-,, SEE DETAIL 2/A6.3. 4 M.A.P.S, LINE VERTICAL CHASE THRU CEILING, WALL R.A, DIFFUSER SEE MECHANICAL, SEE ELEVATION 6/A8.0, KEY NOTES F E m C 0 0 INCORPORATED engineering . architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA .33014 PHONE: ( 305) 558-4124 FAX: (305) 626-0619 E B#0004432 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBIJSH ARCHITECT -AR 2808 O IL CONTRACT DATE: 10-28-2007 BUILDING TYPE K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y0 7 CEILING PLAN PLOT DATE: 2008 FLOORS WALLS LAMINATES WALLS CEILINGS SYM DESCRIPTION ALTERNATE / NOTE ,YM DESCRIPTION ALTERNATE / NOTE SYM DESCRIPTION ALTERNATE / NOTE DESCRIPTION ALTERNATE / NOTE T-1 MFR.: DAL -TILE WC -1 MFR.: FORBO WAINSCOT PANELS, ALUMINUM CORNER TRIMS P-12 MFR.: SHERWIN-WILLIAMS LOCATION: DINING ROOM LOWER WALLS, CL -1 MFR,: TYPE: SURETREAD QUARRY TYPE: MARMOLEUM AND J -MOLDS BY DECOR VENDOR "TYPE: RESTROOM PASSAGE WALLS TYPE: OPEN TO STRUCTURE COLOR: RED 0081 COLOR: 3174 SAHARA LOCATION: DINING ROOM WALLS COLOR: SW#61'17 "SMOKEY TOPAZ" COLOR: P-20 SIZE: 6"x6" TRIM: BRONZE FINISH: LATEX SATIN/EGG SHELL GROUT: MAPEI #47 CHARCOAL T-2 MFR.: CROSSVILLE TYPE: COLOR BLOCK SERIES PORCELAIN TILE WC -2 MFR.: FORBO "TYPE: MARMOLEUM WAINSCOT PANELS, ALUMINUM CORNER TRIMS P-13 MFP.: SHERWIN-WILLIAMS LOCATION: DINING ROOM WALLS CL -2 MFR.; NOTE: 1/2" GYPSUM BOARD OVER 2x FRAMING COLOR: A11077 "MUD PIE" COLOR: 3127 BLEEKERSTREET AND J MOLDS BY DECOR VENDOR TYPE: COLOR: SNI/A6362 "TIGER EYE" TYPE: GYPSUM BOARD COLOR: P-11 a) 24" O.C. COORDINATE FRAMING WITH SIZE: 12" X '12" TRIM: BRONZE LOCATION: DINING ROAM WALLS FINISH: LATEX SATIN/EGGSHELL MECHANICAL and ELECTRICAL FIXTURES. GROUT: LATICRETE #35 MOCHA, SANDED T-3 MFR.: CROSSVILLE TYPE: COLOR COLOR BLOCK SERIES PORCELAIN TILE COL �, P-13 MFR.: .�HERNJIN-WILLIAM: "TYPE: LOCATION: DOOR FRAMES CL -3 MFR.: ACOUSTIFLEX CORP. MFR.: US GYPSUM CO. "CAMPING OUT" TYPE: CAPAUL VINYL ROUT(, #1140, WASI!ABLE NON -PERFORATED, 24'k4TH2" TYPE: PANEL #3270 -2 -MIL SIZE: 12" X 12" COLOR: SW#6362 "TIGER EYE"ALTERNATE: SVS/ #6117 "SMOKEY TOPAZ" COLOR: WHITE COLOR: WHITE VINYL GROUT: LATICRETE #35 MOCHA, SANDED FINISH: ENAMEL (ENAMEL) GRID: WHITE SUSPENSION GRID W/ ALUMINUM FACE NOTE: FIRE CODE C NOTE: FLAME SPREAD RATING 0-25, CLASS NOTE: SEE SPECIFICATIONS P-14 MFR.: BENJAMIN MOORE LOCATION: DINING ROOM WALLS, KITCHEN CL -4 MFR.: USG NOTE: FACTORY PAINT TO MATCH P-16 "CAVIAR" TYPE: WALLS. TYPE: 24" x 24" (GRID, TILES AND VENTS) COLOR: BM #2152-40 "GOLDEN TAN" COLOR: FROST CLIMA PLUS 414-205 FINISH (DININ(3): LATEX SATIN/EGGSHELL GRID: PRELUDE ML EXPOSED TEE, BLACK FINISH (KITCHEN): EPDXY/ HIGH -GLOSS NOTE: FLAME SPREAD RATING 0-25, CLASS P-16 MFR,: SHERWIN WILLIAMS LOCATION: DINING=, CEILING TYPE: GRID COLOR: SW #6990 "CAVIAR" FINISH: LATEX SATIN/EGGSHELL P-'17 MFR.: BENJAMIN MOORE LOCATION: RESTROOM CEILING TYPE: COLOR: BM READY MIX SUPER WHITE FINISH: LATEX SATIN/EGGSHELL P-18 MFR.: BENJAMIN MOORE LOCATION: DINING ROOM BULKHEAD, MENU TYPE: BOARD SOFFIT, ORDER AREA WALL COLOR, BM #310 "COUNTRY REDWOOD" FINISH: AQUA PEARL P-19 MFR.: SHERWIN WILLIAMS TYPE: STAIN COLOR: SW #312.1-8 "PEARWOOD" TYPE: 1X2 WOOD TRIM LOCATION: DINING ROOM CHAIR RAIL P-20 MFR.: BENJAMIN MOORE LOCATION: LOBBY (OPEN CEILING), TYPE: RESTROOM WALLS COLOR: BM #HC -85 "FAIRWEIN TAUPE FINISH: LATEX SATIN/EGGSHELL FRP1 N1FR.: MARLITE TYPE: FIBERGLASS REINFORCED PANEL COLOR: FP -100 WHITE NOTE: NO COLOR VARIATIONS ACCEPTED WALL RASE DOORS DOORS IFR.: MARLITE FRP-2 TY LOCATION: CHICKEN BREADING AREA ONLY. MILLWOIK E: FIBERGLASS REINFORCED PANEL ,M� COLOR, FP -100 WHITE NOTE: NO COLOR VARIATIONS ACCEPTED TEXTURE: SMOOTH SYD/1 DESCRIPTION ALTERNATE / NOTE aYM DESCRIPTION ALTERNATE / NOTE n ,GYM DESCRIPTION ALTERNATE / NOTE B-1 MFR.: DALTILE "TYPE: DL -'1 MFR.: WILSONART SANITARY COVE "r TYPE: LAMINATE PL -1 MFR.: WILSONART COLOR: REDTo MATCH '1 COLOR: #10776-60 KENSINGTON MAPLE TYPE: LAMINATE SIZE: 5''x6" FINISH: #60 COLOR: #9721-38 TUSCAN WALNUT GROUT: MAPEI !>E47 CHARCOAL B-2 MFR.: CROSSVILLE S-1 NIFR.: FORMICA SIGNATURE TYPE: COLOR BLOCK SERIES PORCELAIN TILE TYPE: SOLID SURFACE MATERIAL COLOR: A11071 `MUD PIE" COLOR: #742 BLANCO TERRAZZO SIZE: 6" X 12" COVE BASE GROUT: LATICRETE #35 MOCHA, SANDED WT -I MFR.: CROSSVILLE LOCATION: ONE WALL EACH RESTROOM. SEE TYPE: COLOR BLOX SERIES PORCELAIN TILE A8,1 FOR LOCATION. COLOR: #AI 15 "CAMPING OUT' SIZE: 12' X '12" GROUT: LATICRE"rE #35 MOCHA, SANDED OPTIONAL GROUT: TEC COFFEE 969 WT -2 MFR.: CROSSVILLE LOCATION: "TOP COARSE OF WALL TILE, ONE TYPE: COLOR BLOX SERIES PORCELAIN TILE WALL EACH RESTROOM. SEE COLOR: #A115 "CAMPING OUT" A8.1 FOR LOCATION, SIZE: 3-1/2' X121 BULLNOSE GROUT: LATICRETE #35 MOCHA, SANDED OPTIONAL GROUT: TEC COFFEE 969 DALTILE L.M. SCOFIELD COMPANY 1. INSTALL FRP ON KITCHEN SIDE OF SERVING-{ COUNTER WALL, LESLIE S. LIKINS 800-900-9900 502-637-2750 2. GALV STEEL WALL AND CEILING FINISHES BY WIC / WIF BOX MFR, LESLIE. LIKINS@DALTILE.COM HYDROMENT JAENNE ATK INSON 3. REFER TO INTERIOR ELEVATIONS FOR LOCATIONS OF TILE AND FRP. MARLITE 248-478-3958 TM -1 MFR.: MILLWORK CONTRACTOR MFR.: UALEY'S V/OOD CAIN DAN EGBERS CELL 810-459-1009 TYPE: CHAIR RAIL TYPE: 4. FOR FINISH LOCATION; REFER TO: 330-343-6621 COLOR: STAINEG'TO MATCH COLOR: LIGHT CHERRY SHEETS A4,0 & A4.1 - EXTERIOR ELEVATIONS WWW.MARLITE.COM OMNOVA SOLUTIONS WILSONART #7909-60 FUSION MAPLE CONTACT: 800-735-7019 SHEET A7.0 - FLOOR FINISH PLAN 175 GHENT ROAD NOTE: 1 X 2 SOLID MAPLE LOCATION: DINING ROOM. SHEET ATI - REFLECTED CEILING PLAN SHERWIN-WILLIAMS FAIRLAWN, OH 44333 SHEETS A8.0 TO A8,3 - INTERIOR ELEVATIONS BRAD HARRINGTON MATT ORLY 216-341-5553 ext 115 330-869-4385 5, APPROVED PAINT MANUFACTURERS: Cell: 216-210-2723 BENJAMIN MOORE, PORTER, SHERWIN WILLIAMS, ICI, & PITTSBURGH PAINTS. BRAD. E. HARRINGTON(�OSHERWIN.COM BENJAMIN MOORE ALTERNATE MFRS. SHALL MATCH SPECIFIED SCHEDULE COLORS EXACTLY. DOROTHY HAZINSKI CROSSVILLE 800-635-5147 ext, 1841. 6. ALL PAINTED SURFACES SHALL HAVE A SPRAY APPLIED "LIGHT ORANGE PEEL" MIKE MATHEWS TEXTURE, LOUISVILLE TILE DISTRIBUTOR 4520 BISHOP LANE LOUISVILLE, KY40218 502-452-2037 NATIONAL ACCOUNT DIVISION 800-369-7671 ROOM FINISH NOTES D CONTACTS C ROOM FINISH SCHEDULE LEGEND A INCORPORATED engineering. architecture. planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: 0305) 558-4124 FAX: (305) 826-0619 EB#0004432 v SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 A A 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y0 7 PLOT DATE: 2006 I 0 r I ®I N I N G 3/8"=1'-o° w rrQ 0 aj ORDINATE TRUSS ELEVATION FH CMU or WOOD FRAME ,NSTRUCTION TYPE, I c c 4'-8-2" a PASSAGE 3/8"=I' -o" DINING I INCORPORATED engineering • architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-41124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 Q WINDOWSILL. SEE 4/A, ,A, CONTRACT DATE: '10-28-2007 H.C. SIGNAGE BUILDING TYPE: K -y07 Q PROVIDE CLEAR SILICONE CAULK WHERE ALL FIXED AND BUILT-IN COUNTERS / PLAN VERSION: 2007-D EQUIPMENT ABUT WALL SURFACES. WHERE GAP BETWEEN WALL AND COUNTER SITE NUMBER: 297909 SPLASH/ EQUIPMENT EXCEEDS 1/4", PROVIDE S.S. CLOSURE ANGLE. STORE NUMBER: W750279 Q 18 GAUGE STAINLESS STEEL CHASE, DRAWING DA"rE: 3-11-2008 6 DROP PENDANT LIGHT FIXTURE, SEE SCOPE OF WORK AND SHEET E4.0. KFC 6 TRACK MOUNTED LIGHT FIXTURE. SEE SCOPE OF WORK AND SHEET E4.0, 3601 S ORLANDO DRIVE 8"x8" OPENING FINISHED WITH FRP FOR SYRUP TUBES. SEE 19/A6.3 AND SHEETAI,O. SANFORD ,FLORIDA 8 NOT USED. FOR ARTWORK DESCRIPTION, REFER TO ARTWORK SCHEDULE ON SHEET A2.0. 10 BOTTOM OF BEVERAGE AND ICE DISPENSING LEVERS SHALL BE NO HIGHER THAN 42" A.F.F. E 11 CHAIR RAIL, REFER TO DETAIL 14/A6.3, K -y07 .12 SS CORNER / END WALL CHANNEL GUARD, FULL HEIGHT. SEE 10/A6.3. NOT USED, INTERIOR .14 MENUBOARD BULKHEAD, ELEVATIONS 15) KFC PUB SIGN. OWNER SUPPLIED. 1: 6�) GYP. BD. OVER FURRING STRIPES @ 16" U.C. BETWEEN DOOR FRAME AND CORNER DINING OF DINING ROOM, THIS AREA ONLY, SEE DETAILS I VAG.1 and 12/A6.2. 17 KFC NEON SIGN. OWNER SUPPLIED, Aa'"�'m 0 KEY NOTES A PLOT DATE: 2006 WOMEN'S RESTROOM 3/8I'= 1'-0" J I MEN'S RESTROOM 3/81, q FvTFE-g F /VT -1 ICJ , MEN'S RESTROOM 3/&'= 1'-o" I L \\-- =B-2 �—/ WOMEN'S RESTROOM 3/8" =1'-0" 1 F I WOMEN'S RESTROOM 3/8" =1'-3" O I B-265 BB-24� WOOD FRAME CONSTRUCTION 10.) ONLY MEN'S RESTROOM 3/a" =1'-0" I I -050 `r I WOMEN1--._ __ - '> 4'0" �: `. I B-305 WK =- - -- ...... .......... ------J-------- ------ I I ...—............. ... --,— �— B-275 MEN L — PROVIDE 2x BLOCKING AT ALL WALL MOUNTED A8.0 5 B 300 ACCESSORIES, PASSAGE P : A8.1 H ? - GRAB BARS, FASTENERS AND MOUNTING DEVICES 7 SHALL BE INSTALLED PER ADA REQUIREMENTS. REFER TO SH FET ADA1,0, N Z ....... -------- ._..._.. _..._., .. I _ - REFER TO FLOOR PLAN NOTES FOR BLOCKING AND ................ _.... ....:............... SUBSTRATE NOTES. ....... ......... .......... .......... .......... ..__ . ....... _ REFER TO SHEETADAI.0 FOR MOUNTING HEIGHTS AND g� CLEARANCES OF ACCESSORIES AND FIXTURES. _. ALCOVE i_- L _. ......-... _........ ........ ....._.. .......:::_----. ... ...:. ''" B 241,,,—\ ALL DIMENSIONS THIS DRAWING ARE TO FINISH c? SURFACE. FOR DESCRIPTIONS, REFER TO ARTWORK SCHEDULE ON SHEET A2.0. 7NLARGED RESTROOM/OFFICE PLAN / GENERAL NOTES N.T.S OFFICE ELEVATION 3/8"=1' o" 1 ® I OFFICE ELEVATION 3/8"=1'-o" 7I OFFICE ELEVATION 3/8"=1'-o" R I (._D THERMOSTAT CONTROLS. <~ 2 LIGHTING CONTROL SWITCHES. 'TELEPHONE TERMINAL BOARD 4 j HOLD UP BUTTON 12" DEEP WHITE MELAMINE SHELVING W" 16" SHELF BRACKETS. SEE DETAIL 4/A6,3, 6� UNDER COUNTER KEYBOARD TRAY. '12" X1 2" PHONE DISTRIBUTION BOX: OWNER PROVIDED & INSTALLED. <__8) ANGLE BRACKETS PER DETAIL 4/A6,3 (TYP. OF 4). BRACKET A-FfACHED TO STUD PER DETAIL 4/A6.3, SHALL BE A MAXIMUM OF 16" FROM END OF COUNTERTOP. ( 10.) 1/2" METAL REVEAL (WOOD FRAME CONSRUCTION ONLY), NOTE: SEE DETAIL 1/ADA1.0 FOR ACCESSIBILITY MOUNTING HEIGHTS AND CLEARANCES, INC— ORPOF�ATE D engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 _ MIAMI LAKES, FLORIDA 33014 PHONE:305 558 4124 FAX: 305 826 0619 E13#0004432 (0, -........._SEAL l EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 q W750279 DRAWING DATE: I -f� -Y WOOD FRAME CONSTRUCTION 10.) ONLY MEN'S RESTROOM 3/a" =1'-0" I I -050 `r I WOMEN1--._ __ - '> 4'0" �: `. I B-305 WK =- - -- ...... .......... ------J-------- ------ I I ...—............. ... --,— �— B-275 MEN L — PROVIDE 2x BLOCKING AT ALL WALL MOUNTED A8.0 5 B 300 ACCESSORIES, PASSAGE P : A8.1 H ? - GRAB BARS, FASTENERS AND MOUNTING DEVICES 7 SHALL BE INSTALLED PER ADA REQUIREMENTS. REFER TO SH FET ADA1,0, N Z ....... -------- ._..._.. _..._., .. I _ - REFER TO FLOOR PLAN NOTES FOR BLOCKING AND ................ _.... ....:............... SUBSTRATE NOTES. ....... ......... .......... .......... .......... ..__ . ....... _ REFER TO SHEETADAI.0 FOR MOUNTING HEIGHTS AND g� CLEARANCES OF ACCESSORIES AND FIXTURES. _. ALCOVE i_- L _. ......-... _........ ........ ....._.. .......:::_----. ... ...:. ''" B 241,,,—\ ALL DIMENSIONS THIS DRAWING ARE TO FINISH c? SURFACE. FOR DESCRIPTIONS, REFER TO ARTWORK SCHEDULE ON SHEET A2.0. 7NLARGED RESTROOM/OFFICE PLAN / GENERAL NOTES N.T.S OFFICE ELEVATION 3/8"=1' o" 1 ® I OFFICE ELEVATION 3/8"=1'-o" 7I OFFICE ELEVATION 3/8"=1'-o" R I (._D THERMOSTAT CONTROLS. <~ 2 LIGHTING CONTROL SWITCHES. 'TELEPHONE TERMINAL BOARD 4 j HOLD UP BUTTON 12" DEEP WHITE MELAMINE SHELVING W" 16" SHELF BRACKETS. SEE DETAIL 4/A6,3, 6� UNDER COUNTER KEYBOARD TRAY. '12" X1 2" PHONE DISTRIBUTION BOX: OWNER PROVIDED & INSTALLED. <__8) ANGLE BRACKETS PER DETAIL 4/A6,3 (TYP. OF 4). BRACKET A-FfACHED TO STUD PER DETAIL 4/A6.3, SHALL BE A MAXIMUM OF 16" FROM END OF COUNTERTOP. ( 10.) 1/2" METAL REVEAL (WOOD FRAME CONSRUCTION ONLY), NOTE: SEE DETAIL 1/ADA1.0 FOR ACCESSIBILITY MOUNTING HEIGHTS AND CLEARANCES, INC— ORPOF�ATE D engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 _ MIAMI LAKES, FLORIDA 33014 PHONE:305 558 4124 FAX: 305 826 0619 E13#0004432 (0, -........._SEAL l EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2003 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA L�SS Ni: K -y07 INTERIOR ELEV ENLARGE RESTROOMS OFFICE PLAN KEY NOTES N.T.S. PLOT DATE: 2008 C F T ib 7 Co DRIVE-THRU 3/8" _ "1' o" DRY STORAGE 3/8" - 1 KEG COOK PREP 3/8" = V-0° D MOP SINK 3/8" = 1'-0" FR7`21 K 269 K-274 P-6( 1 B-1 (2) Fm DPEN KFC GOOK 3/811 =1-a WARE WASHING ®RIVE•THRU 3/8"=1'-0" INCORPORATED engineering. architecture . planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 1 L, SEAL EDUARDOL CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 Q 6" STAINLESS STEEL CHASE FOR ICE MACHINE REFRIGERANT LINES. CONTRACT DATE: 10-28-2007 Q ANSUL CABINET. BUILDING "TYPE: K -y07 Q 8" x 8" OPENING FINISHED WITH FRP FOR SYRUP TUBES, SEE 19/A6.3. PLAN VERSION: 2007-D Q SS CORNER/ END WALL CHANNEL GUARD, FULL HEIGHT. SEE 10/A6.3. SITE NUMBER: 297909 STORE NUMBER: W750279 HOLD-UP BUTTON, SEE S/5.0. DRAWING DATE: 3-11-2008 SS CORNER GUARDS AT PERIMETER OF D/T WINDOW, SEE 8/A6,1, Q, KFC HAND SINK FOOT PEDAL. SEE 7/P6,0 P� 5� Q� 3601 5 ORLANDO DRIVE Q EDGE OF 20 GAGE STAINLESS STEEL PANEL BEHIND HOOD. t— ' �Q J�Q�Q�,� SANFORD , FLORIDA f�("� SPLASH r SEE n �`� �� G)o D SS SPLASH GUARD. SEE DETAIL 7/Aa.3, FC-) Q 0 FRP AT BOTTOM OF iMENUBOARD BULKHEAD, �O 1 PROVIDE CLEAR SILICONE CAULK WHERE ALL FIXED AND BUILT-IN COUNTERS / EQUIPMENT ABUT WALL SURFACES. WHERE GAP BETWEEN WALL AND COUNTER SPLASH / EQUIPMENT EXCEEDS 1/4", PROVIDE S.S. CLOSURE ANGLE. K 12 5 1/2" X 5 1/2" '18 GA SHROUD FROM CEILING TO TABLE TOP FOR SYRUP BUNDLE, ' —y0 l% SCREWED TO WALL. 13 GAS RISER. 14 WALL -MOUNTED SAUCE DISPENSER BRACKET. INTERIOR 15 ANSUL PULL STATION. ELEVATIONS 16 SS END SKIRT, KITCHEN N 17 SECURITY SYSTEM KEYPAD, SEE E5.0. 2 KEY NOTES PLOT DATE: 2008 .......... FF1P-2 � FRP-2 F I— K-274 P-6( 1 B-1 (2) Fm DPEN KFC GOOK 3/811 =1-a WARE WASHING ®RIVE•THRU 3/8"=1'-0" INCORPORATED engineering. architecture . planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 1 L, SEAL EDUARDOL CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 Q 6" STAINLESS STEEL CHASE FOR ICE MACHINE REFRIGERANT LINES. CONTRACT DATE: 10-28-2007 Q ANSUL CABINET. BUILDING "TYPE: K -y07 Q 8" x 8" OPENING FINISHED WITH FRP FOR SYRUP TUBES, SEE 19/A6.3. PLAN VERSION: 2007-D Q SS CORNER/ END WALL CHANNEL GUARD, FULL HEIGHT. SEE 10/A6.3. SITE NUMBER: 297909 STORE NUMBER: W750279 HOLD-UP BUTTON, SEE S/5.0. DRAWING DATE: 3-11-2008 SS CORNER GUARDS AT PERIMETER OF D/T WINDOW, SEE 8/A6,1, Q, KFC HAND SINK FOOT PEDAL. SEE 7/P6,0 P� 5� Q� 3601 5 ORLANDO DRIVE Q EDGE OF 20 GAGE STAINLESS STEEL PANEL BEHIND HOOD. t— ' �Q J�Q�Q�,� SANFORD , FLORIDA f�("� SPLASH r SEE n �`� �� G)o D SS SPLASH GUARD. SEE DETAIL 7/Aa.3, FC-) Q 0 FRP AT BOTTOM OF iMENUBOARD BULKHEAD, �O 1 PROVIDE CLEAR SILICONE CAULK WHERE ALL FIXED AND BUILT-IN COUNTERS / EQUIPMENT ABUT WALL SURFACES. WHERE GAP BETWEEN WALL AND COUNTER SPLASH / EQUIPMENT EXCEEDS 1/4", PROVIDE S.S. CLOSURE ANGLE. K 12 5 1/2" X 5 1/2" '18 GA SHROUD FROM CEILING TO TABLE TOP FOR SYRUP BUNDLE, ' —y0 l% SCREWED TO WALL. 13 GAS RISER. 14 WALL -MOUNTED SAUCE DISPENSER BRACKET. INTERIOR 15 ANSUL PULL STATION. ELEVATIONS 16 SS END SKIRT, KITCHEN N 17 SECURITY SYSTEM KEYPAD, SEE E5.0. 2 KEY NOTES PLOT DATE: 2008 2 F_E-234�� I \rlREj—/ CMU CONSTRUCTION P-14 4 M.A.P.S. LINE (WALK UP SIDE) 3/8" =1'-o,, CNIU CONSTRUCTION P-14 rc�� CMU CONSTRUCTION P-'14 5 K 269 C)PEN BUILDING TYPE: K -y07 PLAN VERSION: CMU CONSTRUCTION P-14 4 M.A.P.S. LINE (WALK UP SIDE) 3/8" =1'-o,, CNIU CONSTRUCTION P-14 rc�� CMU CONSTRUCTION P-'14 5 C-001 P-601 B-1 OPEN U-070 U-"100 �----_--_-_ i7O O O --r,------F-1 I 11' F7 10 B 1 B-'1 [a] M.A.P.S. LINE (®RIVE-THRU SIDE) 3/8 '11-01 KITTEN 3/8" =1' o" UTILITY 3/8"='I '-o" SERVING AREA 3/8" =1'-o" UTILITY 3/8"-11-01 (") WATER HEATER VENT SEE PLUMB DWGS. HOLD-UP BUTTON, NOT USED. SS CORNER / END WALL CHANNEL GUARD, FULL HEIGHT. SEE 10/A6.3. FAN MOTOR STARTERS, SURFACE MOUNTED. TYP, OF 2 '=6 SS CORNER GUARD @ SERVICE DOOR HEAD & JAMB. SEE -13/A61. LIGHTING CONTROL PANEL. =8J LIGHTING CONTROL RELAYS (CONTACTORS). 16" W X 4" D CONTINUOUS STAINLESS STEEL CHASE. EXTEND 2" ABOVE CEILING. 10 ELECTRICAL PANELS IN FURRED WALL, SEE '18/A6.2, KEY NOTES GROUP INCORPORATED engineering. architecture. planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: j F1 F L STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 EN I jill I C-001 P-601 B-1 OPEN U-070 U-"100 �----_--_-_ i7O O O --r,------F-1 I 11' F7 10 B 1 B-'1 [a] M.A.P.S. LINE (®RIVE-THRU SIDE) 3/8 '11-01 KITTEN 3/8" =1' o" UTILITY 3/8"='I '-o" SERVING AREA 3/8" =1'-o" UTILITY 3/8"-11-01 (") WATER HEATER VENT SEE PLUMB DWGS. HOLD-UP BUTTON, NOT USED. SS CORNER / END WALL CHANNEL GUARD, FULL HEIGHT. SEE 10/A6.3. FAN MOTOR STARTERS, SURFACE MOUNTED. TYP, OF 2 '=6 SS CORNER GUARD @ SERVICE DOOR HEAD & JAMB. SEE -13/A61. LIGHTING CONTROL PANEL. =8J LIGHTING CONTROL RELAYS (CONTACTORS). 16" W X 4" D CONTINUOUS STAINLESS STEEL CHASE. EXTEND 2" ABOVE CEILING. 10 ELECTRICAL PANELS IN FURRED WALL, SEE '18/A6.2, KEY NOTES GROUP INCORPORATED engineering. architecture. planning '15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -yo 7 ,� � PLOT DATE: 2008 TOTAL SEATS ACCESSIBLE SEATS 1 -20 1 21 - 40 2 4'1 - 60 3 61 -80 4 81 -100 5 101 -120 6 121 -140 7 NUMBER OF ACCESSIBLE SEATS 3U" MIN ELEVATION CORRISPONDING REACH HEGHTS FOR GIVEN DEPTHS; WHEN D = 10" OR LESS, H = 54" MAX. WHEN D = 10", H = 53.5" MAX, WHEN D = 12', H = 53.0" MAX. WHEN D = 13", H = 52.5" MAX WHEN D = 14", H = 51.5" MAX, WHEN D = 15", H = 51.0" MAX. WHEN D = 16", H = 50.5" MAX, WHEN D = 17", H = 50,0" P11AX. WHEN D = 18", H = 49.5" MAX. WHEN D = 19", H = 49.0" MAX. WHEN D = 20" H = 48.5" MAX. WHEN D = 21", H = 47.5" MAX, WHEN D = 22", H = 47.0" MAX. WHEN D = 23" , H = 46.5" MAX. WHEN D = 24", H = 46.0" MAX, 1011 MAX. 301' I 24� CONDIMENTS REACH RANGES N.T,S, 114] ACCESSIBLE RESTROOM DOORS N.T,S. 15 59-3/4" RECOMMENDED MOUNTING HEIGHT, OFF FLOOR FOR BARRIER -FREE DESIGN PROTRUDING OBJECT FREESTANDING OBJE MOUNTED ON POSTS PYLON MAY OVERHA MAX FROM 27" TO 80" ABOVE FINISH FLOOR OBJECT PROJECTION WALL BETWEEN; 27" T ABOVE FINISH FLOOR PROTRUDE NO MORE 4" ACCESSIBLE ROUTE OBJECT PROJECTION FROM WALL LESS TH 27" ABOVE FINISH FLO MAY PROTRUDE'ANY AMOUNT FLOOR SHALL BE SLIP -RESISTANT SURF AND LEVEL WITH MAX CHANGE IN LEVEL FINISH FACE OF WALL 91 S I I• COMBINATION PAPER TOWEL DISPENSER/ TRASH RECEPTACLE [nLl i 711J r) a° - r G cl)F- 1:9 r LI 1/16" co CT NG 1 4 811 1911 3UII CLEAR OR X a CLEAR U 12" f' - 1211 NOTE: MAINTAIN 44" MIN. �F FROM O 80" SHALL 19 THAN LL z 36" MIN, CLR. co AN OR ,,\ � of ACE \.'.; 1/41' INT. ACCESS. ROUTE CLEARANCES1101 SIGN POST OBSTRUCTION ACCESSIBLE ROUTE WALK PROTRUDING HAZARDS 1/211 = V-0" 111 I MIRROR MTD @ 40"A.F.F. MAX TO BOTTOM OF REFLECTING SURFACE LAV. INSULATE HOT WATER & DRAIN 3'-0" S.S. GRAB BAR PIPES OPTIONAL CUP T.S. COVER DISPENSER DISPENSER PAPER TOWEL DISPENSER CONTROLS MOUNTED ON PULL STATION \WIDE SIDE OF TOILET AREA 14" MIN, PROJECTION FROM WALL URINAL \�3'-6" S.S. GRAB BAR J F ) CE �F ? x u 2 - N N g 1 Ti I2 c 7" - 0 Eli I �6" MAX. DEPTH x 30" MIN. WIDTH TOE CLEARANCE SWITCHES 8" MIN. DEPTH x 30" MIN, THERMOSTAT WIDTH KNEE SPACE FIRE ALARM 2 L cc r Z r BABY CHANGE STATION MOUNTING HTS. & CLEARANCES FOR ACCESSIBILITY BY THE DISABLED 3/8" ACCESSIBLKE URNIAL 3/4" =1'-0"6 I GRAB BAR SHALL BE 1-1/2" MAX., OUTSIDE DIA.- TYPICAL CLR. 2- 1/4"x3' EXPANSION ANCHORS AT — MASONRY OR CONC. WALL 2- #10x2" SCREWS AT WOOD OR STEEL STUD WALL- TYP. ,1/8"x2" BENT PLATE WELDED TO RAIL AND 1/8"x3" DIAMETER MOUNTING PLATE Co) 11'-0" 2"x6" BLOCKINc;1 AT WOOD ,13 TUD WALLS (OMIT BLOCKING AT MASONRY OR CONC. WALL) - TYPICAL GRAB BAR 3° I' 0" 7 CLEAR foo -i Lu rr J rn u 0 <L ACCESSIBLE ROUTE 1 4 811 1911 3UII CLEAR X a CLEAR U f' - co NOTE: MAINTAIN 44" MIN. CLEAR AISLE EGRESS PATHS TO EXIT DOORS, CHANGES IN LEVEL N.r.s, 1 � I DINING R®®M ���1TINt� �L�AR®NC�� N.-r.s. 5'01 MIN. (1525) 3'-0" MIN. \PER (455) 6" MAX. (150) ro Tz0 J Z CL D_ J ACCESSIBLE LAVATORY 1. INDICATED DIMENSIONS, HEIGHTS, DEPTHS, AREAS AND OTHER GRAPHIC INFORMATION ARE PROVIDED AS MINIMUMS THAT MUST BE MAINTAINED. THESE MINIMUMS ARE BASED UPON YUM STANDARDS AND MAY EXCEED ADA REQUIREMENTS. ■ INCORPORATED engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FA <: (305) 826-0619 EB#0004432 vs �v SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 0 CONTRACT DATE: '10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD FLORIDA K=y0 7 Q X a r U f' - co O 19 :;T LL ro Tz0 J Z CL D_ J ACCESSIBLE LAVATORY 1. INDICATED DIMENSIONS, HEIGHTS, DEPTHS, AREAS AND OTHER GRAPHIC INFORMATION ARE PROVIDED AS MINIMUMS THAT MUST BE MAINTAINED. THESE MINIMUMS ARE BASED UPON YUM STANDARDS AND MAY EXCEED ADA REQUIREMENTS. ■ INCORPORATED engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FA <: (305) 826-0619 EB#0004432 vs �v SEAL EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 0 CONTRACT DATE: '10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD FLORIDA K=y0 7 DOOR CLOSER IF PROVIDED, SHALL HAVE AT LEAST A 3 -SECOND CLOSING_-; TIME PERIOD FROM 701E OPEN POSITION TO 3" FROM LA'T'CH DOOR HANDLE, ' SEE HARDWARE NOTES 1, 3'-0" DOOR WIDTH 1. T`7P, ENTRANCE / EXIT DOOR N.T.S. 17 GUIDE RAIL ._j a =C .X ❑ m W T Q CE r G TI (j J .o 0 GUIDE RAIL DETAIL HANDRAIL ;r HANDRAIL & CURBS & CURB_r I l 0 [� :;T— WHEEL (_:lUIDE WHEEL GUIDE WHEEL GUIDE DETAIL WHEN DOOR SWINGS WHEN NO DOOR ONTO LANDING - 42" SWINGS ONTO MIN, PLUS DOOR LANDING-;. WIDTH, 60° MIN. SEE NOTE 72" MIN, qS-------- FSE-(�UIF� p 72" 2, MIN. NOTE: MAXIMUM HORIZONTAL DISTANCES OF EACH RAMP AND RUN VARY. RAMP WITH INTERMEDIATE SWITCH BACK PLATFORM CLEAR FLOOR SPACE AT DOOR STRIKE SIDE THRESHOLD -SEE DETAILS 12, 14 / A6.1 DOOR AND HARDWARE PER SHEETA1,1 CLEAR SPACE FINISH ELEVATION TO MATCH FINISH FLOOR ELEVATION AT DOOR SLIP RESISTANT SURFACE (MEDIUM ---�- BROOM FINISH) 60" CROSS -SLOPE 1:50 OR 2% MAX. n NOTE: EXTERIOR DOOR PRESSURE CANNOT EXCEED 8.5 LBS., INTERIOR DOOR PRESSURE CANNOT EXCEED 5 LBS. EXTERIOR DOOR REQUIREMENTS 1/2" __ V-0" 113] MIN. 60 DEGREE SI_ BOTTOM RAIL OF C ALUMINUM THRESI #10 S.M. IN PLASTI, EXPANSION ANCH( BOTTOM RAIL (EXTERIOR DOOR) 3" = I' -o" 14 NOTE 1: WHEN DOOR SWINGS ONTO LANDING 42" MIN, PLUS DOOR WIDTH NOTE 2: 60" MIN. WHEN NO MAXIMUM HORIZONTAL DOOR SWINGS ONTO DISTANCE OF EACH LANDING RAMP AND HUN VARY SEE NOTE 2 �l SEE NOTE 1 sEE NO`rF_ 2 —1 60MIN. I----- 7211 MIN, f O"IIVf�N. r TOP PLATFORM As }-' INTERMEDIATE LEVEL �f-G�IJIf��� BOTTOM LEVEL PLATFOFHI TFORM STRAIGHT RAMP RUN 24" MIN, EXTERIOR AND — 18" MIN. INTERIOR BEYOND THE STRIKE EDGE OF A GATE OR DOOR ON THE SIDE TOWARD WHICH IT SWINGS. I 60" MIN. RAMP LANDING AT DOORWAY NOTE]: NOTE 2: WHEN DOOR SWINGS MAXIMUM HORIZONTAL 60" MIN. WHEN NO ONTO LANDING, 42" DI>IANCE OF GEACH DOOR SWINGS ONTO MIN, PLUS DOOR WIDTH RAMP AND RUN VARY LANDING SEE NOTE 2 ISEE NOTE NOTE E NOTE 2 �E j 60" MIN• TOP PLATFORM 72" " INTERMEDIATE LEVEL f�J f'f=QUlf,�O PLATFORM "�-- INTERMEDIATE LEVEL AS REQUIRED TURNING PLATFORM RAMP WITH TURNING PLATFORM RAMPS N.T.S. Lu III Cc CIa _Z Q PATH OF TRAVEL RLOUIHE D - "' FROM PUBLIC SIDEWALK l0 DETECTABLE WARNINGS WHEN E ACCESSIBLE ROUTE CROSSES STORE ENTRANCE @05% AX. RUNNING SLOPE AND 2% AX. HAZARDOUS VEHICULAR WAY xG m CROSS SLOPE. (I.E, A DRIVEWAY) — y ir `S Jf :.:........... m� ..:: 7„ \ z 5% MAX. 5% MAX. MAX. -.y o co cQ EXIT ONLY ----NO--- PARKING WHERE A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE: NOT SEPARATED BY CURBS, RAILINGS, OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDRY BETWEEN THE AREAS MUST BE DEFINED BY A CONTINUOUS, YELLOW, 36” WIDE DETECTABLE WARNING STRIPE THAT DIFFERS FROM ADJOINING WALKING SURFACE IN RESILIENCY OR SOUND ON CANE CONTACT. 11' MIN. I, 5' MIN 8' MIN T (1) VAN ACCESSIBLE STALL & (1) STANDARD ACCESSIBLE STALL 1. Lu w r,0, c- 0rr w J Lq9� mco E) w co U U U Q Qz z0 O� zz w� � z z C 1 co 0 ro CONCRETE ACCESSIBLE PARKING STALL N.T.S. 11 I HANDICAP SIGN Y!N NOTE: VAN ACCESSIBLE SIGN NOT REQUIRED ON UNIVERSAL OR STANDARD STALLS, GALVANIZED METAL SIGN POST FINISH GRADE NOTE: l C, DETAIL IS MEANT AS A GENERAL GUIDELINE. REFER TO LOCAL MUNICIPALITY FOR SIGN TYPE, VERBAGE AND a; P FENSIONS. SIGNS SHALL BE LOCATED SO THAT THEY CANNOT BE OBSCURED BY A VEHICLE PARKED IN I. I. THE SPACE, ACCESSIBLE PARKING SIGN N•-r.s, 12 RETAINING CURE' (IF NECESSARY; POST MOUNTED ISA SIG N WITH ADDITIONAL "VAN ACCESSIBLE" LANGUAGE BOTTOM LANDING, 60" LONG ELEVATION 2% SLOPE, WITH SMOOTH TRANSITION (NO 1/2 LIP; WHEEL -STOP (AWAY FROM AISLE) DIAGONAL 3" STRIPE`;, 36" O.C, WHITE OR BLUE PARKING AND AISLE SLOPE 2% MAX. IN ANY DIRECTION VAN -ACCESSIBLE STALL, 'I V WIDE, 18' LONG LEFT OF ACCESS AISLE DEPRESSED CURB RAMP AT ACCESSIBLE PARKING 6" CURB SIDE FLARES SLOPED AT 10% MAX, CURB CUT AT ACCESSIBLE PARKING L NO PARKING EXTERIOR PATH OF TRAVEL N,T•s. � RAMPS DOWN �IDEV/ALK POST MOUNTED ISA PARKING SIGN 1:12 1:12 SIDEWALK 4' CLEAR MIN, MAX. AMAX. RAMP DOWN, USE LEAST POSSIBLE SLOPE, 8.3% MAX. BOTTOM LANDING 60" MIN, ACCESS AISLE 8' WIDE FOR P 'r)IInnnr- VAN (5' FOR REGULAR) DEPRESSED CURB RAMP REGULAR ACCESSIBLE STALL, 8' WIDE, 18' LONG 36" SQUARE ISA PAVEMENT SIGN NOTE: LOCAL MUNICIPALITY MAY HAVE ADDITIONAL REOUIREMENTS FOR RAMPS THAT SHOULD BE REFERENCED. CURB RAMPS N.T,S CURB RAMPS N.T.S. INCORPORATED engineering • architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 330'14 PHONE: (305) 558-4124 FAX: (305) 826-06.19 EB -#0004432 SE L EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBU SH ARCHITECT" -AP, 2808 co -+7.9" 0 � 0 0 10% AT `o CURB —p- o 0 N 10-28-2007 K -Y07 2007-D 297909 W750279 3-11-2008 6.0" +1.2" 48' WIDE RAMP T z (0.0" PREFERRED) SLOPED AT 8.3% MAX. o 'i' TYP. CURB RAMP ELEVATIONS NOTE: LOCAL MUNICIPALITY MAY HAVE ADDITIONAL REQUIREMENTS FOR RAMPS THAT SHOULD BE REFERENCED. CURB RAMPS N.T.S. INCORPORATED engineering • architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 330'14 PHONE: (305) 558-4124 FAX: (305) 826-06.19 EB -#0004432 SE L EDUARDO L, CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBU SH ARCHITECT" -AP, 2808 I _ KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 0 0 0 0 0 CONTRACT DATE: BUILDING TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: DRAWING DATE: 10-28-2007 K -Y07 2007-D 297909 W750279 3-11-2008 I _ KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 I CMM E N E R A Us 1 1. LOCATE, CUT AND FRAME ROOF OPENINGS AS SHOWN FOR ALL HVAC EQUIPMENT AND EXHAUST FANS 2, IT IS VERY IMPORTANT THAT ACCURATE MEASUREMENTS ARE UtiED WHEN E_OCAiING EXHAUST FAN ROOF OPENINGS TO ENSURE THAT NO ADDITIONAL OFF -SETS S ARE REQUIRED IN -HE EXHAUST Dt-CTWORK. COORDINATE ROOF OPENINGS WITH THE KITCHEN EOUIF%MEN'T. 3. PROVIDE. ANY FRAMING REQUIRED FOR DIFFUSER INSTALLATION IN HARD CEILING N O/ e 1. INSTALLATION SHALL CONFORM TO THE F'_ORIDA ENERGY CODE= & FLORIDA BUILDING, PLUNIBING & ME-CHANICAL CODE:2004 EDIY!ON" FOR COMVERCIAL CONSTRUCTION 2. ALL WORK AND MATERIALS SHALL COMPLY WITH GOVERNING CODES. SAFETY OFDERS AND REGt.,LA T IONS 3. OBTAIN AND PAY FOR ALL NECESSARY PERMITS FEES AND INSPECTIONS REQUIRED B`/ GOVERNING AUTHORITIES. 4. ELECTRICAL SHALL DROVIDE CONDUIT FOR LINE AND LOW VOLTAGE WIRING, LINE VOLTAGE WIRING. SWITCHES, VOL"AGE OVERLOAD DEVICES AND FINAL CONNECTIONS ON HIGH VOLTAGE CONNECTIONS OTHER THAN t NIT HEAT E ALL LOW VOLTAGE WIRING & CONNECTIONS PERTAINNG TO HVAC SHALL BE BY MECHANICAL CONTRACTOR FOR OTHER ELECTRICAL RESPONSIBIL TIES SEE WF -ERE SHOWN ON PLAN:3 J. ANY EQUIPMENT THAT IS SUBSTITUTED SHALL F T IN THE SPACE PROVIDED WITH ADEQUATE ROOM FOR SERVICING) INCLUDING SUBSTITUTE EQUIPMENT NAMED IN THE SPECIFICATIONS. SUBEC A 1 !4" SCALE CRA4I NG OALL L 6. EQUIPMENT SUBSTITUTED FOR APPROVAL. PRIOR TO INSTA_LATION, INCUCAG BUT NOT LIMINTED TO, STRUCTURAL AND ARCHITECTURAL IMPACT CLEARANCE REQUIREMEN'S AND IJTILITY PEOUIRIEMENTS FOR INSTALLATION OF RECHARGEABLE REFRIGERANT LINES FRCDM ICE MACHINE TO CONDENSER ON ROOF, SEE SCOPE OF WORK 7. HVAC UNITS SHALL BE MOUNTED LEVEL CN ROOF CURBS a. ALL DUCTWORK SHALL BE EXTERNALLY INSULA -ED 9. ALL SUPPLY/ I tETURN DUCTS SHALL BE RIGID, WITH THE EXCEPTION OF THE LAST 14'-G WHICH MAYBE -,LEX, 10. SMOKE DETECTOR ;HALL. BE INSTALLED IN THE RETURN AIR DUCT, PRIOR TO ANY CUTSIDE AIR CONNECTIOINS, AND SHAD.. DIEACTI'VATE ROOFTOP I,NIT UPON SENSING SMOKE INCLJDE SMOKE DETECTOR IN THE SUPPLY AIR DUCT ONLY IF REOJiRED BY LOCAL CODE: 11. 12. ALL HOOD EXHAUST DUCTS SHALL BE RIG D 16 GA MINIMUM WELDED DUCT GRIND AA -L WELDS SMOOTH PROVIDE 3M FRE DARRIER D:,CT WRAP FOR ALL HOOD EXHAUST DUCTS SEE 15/M4 0 13. ALL BRANCH DUCTS FEEDING INiJIVID.JAL DIFFUSERS SHALL HAVE DAMPERS AT TAKEC FFS FOR A!R BALANCING PROVIDE ACCESS PANELS TO DAMPERS SEE 8/M4 0 ALL UTILITY PILING E=:OR RTU'S SHALL. RUN JP TF -ROUGH ROOF INSIDE EACH !JNIT,S ROOF CURB 14, ALL OUT: AIR !N-AKE:> SHALL BE A MINIMUM OF 10'-0" FROM EXHAUST FANS AND / OR VENTS 15 E 8W. 1, 0 AND SCOPE Cl;: WORK FC7R DESCRIPTION OF HVAC PACKAGE TO BE PURCHASED THROUGH YUMI BRANDS NATI0NA! CONTRACT I Fi. FINAL HVAC S/STE/I TESTING AND BALANCING SHALT_ BE PERFORMEC BY INDEPENDENT AGENT CONTRACTED DIR=CTI-V BY T HE OWNER A REE -TESL- IS MANDATORY FOR A FALSE START (I E NO POWER,0' ON A3ENT'S ARRIVAL EQUIPMi ENT NOT WIRED, ETC.) AND SHALL. BE A COST INCURRED BY THE G C !N THE EVENT A SYSTEM % STORIE RECEIVES A GRADE OF 5 OR BEELCW AS A RESULT OF THE HVAC SYSTEEM PERFOR MANIC FE P' T ON AL OPE � I O. dAL 17. DEFICIENCIES, OWNER WILL REQUEST A RETEST AND THE COST FUR SAME SHALL BE ALSO INCURRED BY Tri- GENERAL. CONTRAC rCR Nps' TRANS PROGFIAMMABLE-HERMOSTA'r MODEL ibBAYSENSC3198 PROVIDED VVITH TRANEE PACKAGE 18. � TRANE THERMOSTAT SENSOR (REMOTE) MODES_ #14190-7015. PROVIDED WITH TRANE PACKAGE TRANE DUCT MOUNTED HUMIDITY SENSOR MODEL #8AYSENS037A, PROVIDED W TH TRANE PACKAGE O I OUTSIDE AIR CALCMATION NOTE A.5•H R.A.h. 62-1989 REQUIRES OUTSIDE AIR FOR INDOOR AIR QUALITY: DINING ROOMS -20 CFM PER PERSON KITCHEN - 15 CFM PER PERSON CALCULATIONS: DINING - 50 PEOPLE X 20 CFM = 1000 CFM KITCHEN - 8 PEOPLE X I5 CFM = 120 CFM TOTAL REQUIRED = 1120 CFM OUTSIDE AIR PROVIDED = 3350 CFM BY ROOFTOP EQUIP. r SYMBOL & ABBREV. DESCRIPTION A/C, AC SA/SUP SUPPLY AIR (RISE/DROP)- NO RA/RET RETURN AIR DUCT (RISE/DROP) ��� EA/EXI I E=XHAUST AIR DUCT (RISE/DROP) -- - .4 CD/SR CEILING DIF=FUSEER/SUPPLYREGISTER x i FIRE RATED ROOF CEILING ASSEMBLY (ARROWHEAD REPRESENTS NUMBER OF THROW) x , RR/RG �- RETURN REGISTEERJGF;ILLE - � ER/EG E=XHAUST REGISTER/GRILLE !� - :C RECTANGULAR DUCT ELBOW WITH TURNING VANES FLEXIBLE OA,'OSA - OUTSIDE AIR CONNECTION - S/S STAINLESS STEEL__- TYP. UON UTR MVD MANUAL VOLUME DAMPER �- _ UNIT. CURB - . FD FIRE DAMPER CFM CFM FSP HP REAM (MI3H) TONS EER (L) DUCT LINING (1" -THICK. UNLESS OTHERWISE NOTED) WEIGHT MODEL NUMBER REMARKS HEIGHT WEIGHT` ' .. SINGLE LINE DUCT BRANCH TAKEOFF i DUCT TRANSITION (RE CTANGULAR TO ROUND) -- FLEX FLEXIBLE DUCT (14-0 MAXIMUM) (Dr T -STAT � -� PROGRAMMABLE THERMOSTAT PROVIDED WITH T I` � RA IE PACKAGE. (;ts� THERMOSTATSENSOR (REMOTE), PRONDED WITH TRANE PACKAGE. ( RTU -1 HUMIDITY SENSOR (REMOTE), PROVIDED WITH TRANE PACKAGE, T� D -t-DIA. D CONDENSATE DRAIN O 40.5/54 138,186 2 N/A DIAMEETER - DL DL DOOR LOUVER -UC-----R- I UC DOOR UNDERCU-T (3/4" MINIMUM; X X OOOU ' 7200 MECHANICAL EQUIPMENT DESIGNATION I 5 811 GENERAL NOTES r EAC DESIGN REQUIRES:S DESCRIPTION A/C, AC AIR CONDITIONING (Eu NO DUCE SMOKE DETEC1TOR-� X DTR - FIRE DAMPER(")) EF x FIRE RATED ENCLOSURES -� x i FIRE RATED ROOF CEILING ASSEMBLY UC _ x , FIRE STOPPING _ - -y x SMOKE CONTROL MECH x - (N) -- NEW ^, -- OA,'OSA - Florida Building Code (F.B.C) March 2004 Chapter 8 Sx3ction 8-10 Miami Dade Ordinance 01-112 w SYMBOL & ABBREV. DESCRIPTION A/C, AC AIR CONDITIONING BDD CB CEG. CONN. I CONT. CONTR CFM DET. �^ BACK DRAFT DAMPER CIRCUIT BREAKER ---^ CEILING CONNECT/CONNECTION CONTINUATION- CONTRACTOR-� �- CUBIC FEET PER MINUTE DETAIL - DISC. DISCONNECT DTR - DOWN THRU ROOF EF EXHAUST FAN - ,E) - EXISTING GA. GAGE/GAUGE UC _ GENERAL CONTRACTOR HVAC HEATING, VENTILATING, AND AIR CONDITIONING MFR. _ MANUFACTURER MECH MECHANICAL - (N) -- NEW ^, -- OA,'OSA - OUTSIDE AIR 013D OPPOSED BLADE DAMPER S/S STAINLESS STEEL__- TYP. UON UTR TYPICAL UNLESS OTHERWISE NOTED - UP THRU ROOF NOTES: 1. DIFFUSERS IN SURFACE_ MOUNTED CEILINGS SHALL BE PROVIDED WITH OPPOSED BLADE DAMPERS. SEE ARCHITECTURAL DRAWINGS FOR CEILING TYPES. PLAN VERSION 2007-D 'SITE NUMBER: 297969 !� STOHE NUMBER:. 352900" L - +• KFC: I t»m 5A RA OA EA` PRESSURE , ODV I ORLANDO DRIVE; D; F C)RIDA SAI�IFOR EF -1 - FOR COMPLETE ININFORMATION AND PRICING ONTHE TRANE HVAC PACKAGE 2200CFM -2200 CFM CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. EF -2 2006 CFM 20QO CFM ; TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986.4822 FAX: (502) 499-7870 r� EMAIL: mlcusick@trane.aorn 75 CFM' - 75 CFM TRANE HAS AGREED TO SUPPLY AN HVAC PACKAGE CONSISTING OF THE R OF -TOP ----r -_--- UNITS, CURBS, THERMOSTATS, TEMPERATURE SENSORS (REMOTE), AND HUMIDITY EP.4 .- 75 CFM X �/75 CFP/1SENSORS REP�IOTE}. RTU'S Aa SPECIFIED INCLUDE AN UNPOWEREDD CONVENIENCE^'IY, "� OUTLET (SEE ELECTRICAL) AND AN HACK CIRCUIT BREAKER WHICH PROVIDES UNIT DISCONNECT. TRANE ALSO 0 HAV E AVAILABLE OPTION PACKAGES WHICH tINCLUDE SMOKE DETECTORS AND ENUNCIATORS, ECONOMIZERS, AND RTU VARIATIONS SUCH AS HIGH -EFFICIENCY MODELS. �"-- --- -- : BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT MECHANICAL DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN - •< • MAY NOT MATCH NATIONAL DESIGN. ' . SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL INFORMATION. - . • . CHEIRM TIRANE PACKAGE N.T.S. PLOT` DATE; ,• 10,19.0% ', .' � its �1���,. �'i� ,,, � • + , FAN DATA COOLING CAPACITY. HEATING CAPAQrrY UNIT ELECT DATA - _ ''MAX MANUFACTURER r GREASE, IVSD SUPPLY MlN 0 A. MIN CAP NOM MIN INPUT "• OUTPUT HTR;, VOLTS/ UNIT. AND UNIT. CURB - . MARK CFM CFM FSP HP REAM (MI3H) TONS EER STAGE AFUE (MBH) (STAGES) MCA MOCd PH WEIGHT MODEL NUMBER REMARKS HEIGHT WEIGHT` ' .. TOT/SEN ( ) @20E3V (LESS) RTU -1 DINING 6000 2290 1.0 5 9-40 17.5 206,/151 9.8 40.5/54 138,186 2 N/A 208/`x'30 3 162/184 1.75/200 1654 TCD210C3L0 SEE NOTES 1 3,4,Fi,7, 50 RTU -1 DINING 7200 2290 1,0 5 811 20 245/174 9,7 40.5/54 138,186 2 N/A, 3�J 162/184 1;75/200 203.1 TCD241'03LM SEE NOTE$1-3 5 7 54 14 _ SCHEDULE NOTES: 1. LISTED CAPACITY IS THE STANDARD UNITS GROSS COOLING CAPACITY AT 80 DEG. F. DB / 6-1 DEG. F. WB EATAND 95 DEG. F, AM BIEN T, OUTDOOR DESIGN ; CONDITION, SUMMER 95 DEG. F. & 14 DEG. F WB, WINTER 17 DEG, F. (AAI STANDARD CONDITIONS,) 2. SPECIFIED RTUS ARE DOWN DISCHARGE PACKAGED GAS / ELECTRIC ROOFTOP UNITS WITH MINUMUM`2-STAGE COOLING. INCLUDES THROUGH THE ROOF CURB POWER, GAS & CONDENSATE DRAIN. GAS PIPING SHALL BE FACTORY PIPED WITH SHUT-OFF ..0UTSIDE•OF,UNIT. . 3. SPECIFIED UNIT INCLUDES HINGED ACCESS DOORS, 2" PLEATED FILTERS, LOW AMBIENT CONTROL TOO DEG, F., MOTORIZED OUTDOOR AIR DAMPER, CIRCUIT BREAKER WITH SINGLE POINT WIRING, HAIL GUARD, AND FACTORY FABRICATED, KNOCK DOWN ROOF CURES, 4. HOT GAS REHEAT 13 NOT AVAILABLE ON A1 7.5 TON UNIT 5. SPECIFIED UNIT INCLUDES FACTORY INSTALLED HOT GAS REHEAT OPTION INCLUDING REMOTE MOUNTED TEMPERATURE AND HUMIDITY'SENSORS AS INDICATED ON THE DRAWINGS 6. SPECIFIED UNIT INCLUDES SUPPLY AIR TEMPERING CONTROL 7. PROJECT LOCATIONS NEAR COASTAL AREAS MAY REQUIRE EPDXY COATED COILS, HVA i 1T 8 I 0U LE ACCESSORIES 1. UL 762 LISTED (GREASE) MANUFACTURER 2. VENTED ROOF CURB t X XXX) CFM SP RPM HP ELECT LU J AND 'REMARKS3: ROOF CURB UJ LU cn CC MARK cn a MODEL NUMBER it. GREASE TROUGH v� - 5. ,' HINGED ROOF CURES 6, WEATHEROR:OOF DISCONNECT SWITCH COOK 180VH7B EF -1 2200 1.5 1358 1 208/3 - X X X SEE NOTES 1,2,3,4,5 &'6 7., SOLID STATE SPEED CONTROLLER �- -� - OR EQUIVALENT 8: BACKDRAFT DAMPER E F-2 2000 1.5 1:350 1 208/3 X x X COOK SEE NOTES 1,2,:1,4,5 & 6 OR EQUIVALENT . _ VAL' " EF -4 750.5 1050 129W 120/1 X X X COOK GC -160 SEE NOTES 7,8 -- _ OR EQUIVALENT - COOK GC -160 EF -5 75 0.5 1050 129W -1201.1 x X X SEE NOTES,7,8 - OR EOUtVALENT EXHAUST FANSCHEDULE, warri�+�o�1c+aW1Mr*�uartam,®s+®Grp+�rirera�amp�l��ife�„uss+®u�auW�mp+rs�,am�mosml�wwi.saa+u�am�+tm�600rameirviyawl�RWs �2j �MI�tW�q�oemivw 1a�W t#dM®N�wsa1�V>+�YFwr .- DIFFUSER FACE - TYPE (NO.) & AIR MOUNTING DUT`G MATERIAL r PATTERN XX XXX NECK OR (z � i u r H LU SIZE CEILING GRID � `-;- n ct = MANUFACTURER, MODEL NUMBER REMARK:; a r -)LU CrIM D vyJ MARK V SIZE u"'.. w c7 RANGE �5 LU :� 1 4 10x4 11.5x5.7:1 X r (4) 1 W x x ME TAL-AIRE / TITUS V4004 / S300FS- FURNISH. DAMPER/EXTRACTOR, REGISTER TO BE DUCT MOUNTED 0-200 S•2 1 10,10 18"Td XX X X METAL-AIRE / TITUS' 3100A / TMA -AA ` ADJUSTABLE GONE DIFFUSER HORIZONTAL POSITION 0-450 •- ..-.�.-.. - ..--_ ,• , (3)3W,(6)4 S-3 9 12x-12 24x24 X x X X METAL-AIRE / TITUS 500(1-6 / TDC-AA. FRN SQR TO FIND ADAPTER � 0-600 S-4 4 9x9 1 4x1 4 XX �f X METAL.-AIRE/TITUS 6000-1 /TQC -AA _ 0-250 S-5 2 22x72 24x24 x (2) NO DIR X x x METAL.-AIRE/TITUS �65oRAL,-6I13FF PERFORATED HINGED FACE, NO FILTER, SEE DETAIL 6/M4.0 - - 785-1266 FF IN SQR TO RNID ADAPTER S-6 6 18x18 24x24 X (1)`?W'(3)3W'(2) ,/ 0-1000 / x X X _ METAL-AIRE-/ TITUS 5000 6/TOC-AA FpN SQR TO FIND ADAPTER R-1 4 22x12 24x24 x X X X METAL -AIRF; / TITUS GC5-FB-TB / 50FF FULLY REMOVABLE FACE 0-1900 :. F-1-2 1 54x-18 56x20 X X X X PASTAE AIRE /TITUS SRH/350RL _ PAINT TO MATCH WALL - 0-5000 NOTES: 1. DIFFUSERS IN SURFACE_ MOUNTED CEILINGS SHALL BE PROVIDED WITH OPPOSED BLADE DAMPERS. SEE ARCHITECTURAL DRAWINGS FOR CEILING TYPES. PLAN VERSION 2007-D 'SITE NUMBER: 297969 !� STOHE NUMBER:. 352900" L - +• KFC: I t»m 5A RA OA EA` PRESSURE , ODV I ORLANDO DRIVE; D; F C)RIDA SAI�IFOR EF -1 - FOR COMPLETE ININFORMATION AND PRICING ONTHE TRANE HVAC PACKAGE 2200CFM -2200 CFM CONTACT MARTY CUSICK, THE YUM! BRANDS ACCOUNT EXECUTIVE AT TRANE NATIONAL ACCOUNTS. EF -2 2006 CFM 20QO CFM ; TOLL-FREE PHONE: (866) YUM-HVAC or (866) 986.4822 FAX: (502) 499-7870 r� EMAIL: mlcusick@trane.aorn 75 CFM' - 75 CFM TRANE HAS AGREED TO SUPPLY AN HVAC PACKAGE CONSISTING OF THE R OF -TOP ----r -_--- UNITS, CURBS, THERMOSTATS, TEMPERATURE SENSORS (REMOTE), AND HUMIDITY EP.4 .- 75 CFM X �/75 CFP/1SENSORS REP�IOTE}. RTU'S Aa SPECIFIED INCLUDE AN UNPOWEREDD CONVENIENCE^'IY, "� OUTLET (SEE ELECTRICAL) AND AN HACK CIRCUIT BREAKER WHICH PROVIDES UNIT DISCONNECT. TRANE ALSO 0 HAV E AVAILABLE OPTION PACKAGES WHICH tINCLUDE SMOKE DETECTORS AND ENUNCIATORS, ECONOMIZERS, AND RTU VARIATIONS SUCH AS HIGH -EFFICIENCY MODELS. �"-- --- -- : BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT MECHANICAL DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN - •< • MAY NOT MATCH NATIONAL DESIGN. ' . SEE THE SCOPE OF WORK SHEETS FOR ADDITIONAL INFORMATION. - . • . CHEIRM TIRANE PACKAGE N.T.S. PLOT` DATE; ,• 10,19.0% ', .' � its �1���,. �'i� ,,, � • + , LJ LaJ Q z FLANGE @ ROOF LINE FOR SUPPORTING CURB FAN DI CHARGE MIN. 12'1 AE30VE ROOF= SURFACE AND CORROSION RESISTANT BIF30 SCREEN WITH MESH SIZE NO LARGER THAN 1/2" 17 X 17 HOOF FAN / CURB W/DROP IN PLENUM & GRAVITY DAMPER RESTING ON TOP OF FAN CURET. 8" FIND. (SHEET METAL DUCT OVER TO EXHAUST AIR TERMINAL AS SHOWN 10 X 10 PLENUM ✓ �� VOLUME DAMPER - TYP. NOTE: DUCTWORK MAY VARIE: INFIELD APPLICATION EF --3 FAN/PLE1N11 M DETAIL NO SCALE 12 NOTE: FOR WIRING OF AUXILIARY DEVICES E ES R - 'T R FE 0 MANUFACTURER'S INSTALLATION INSTRUCTIC OR CONTACT MANUFACTL I I 1 Y t' , i CIEND 1�ii00 PM} 1 0 ALARM,TROUBLE ANNUNCIATOR e :, REMOTE F�FESEl _- - _ .. -... .. ...... .. .. w.,. .v. ry yr •..vr l •i L,. L,.• Lit-Ir\It 1 1-f > _ A _ � v va iH��u4urVlVVAIkH HtAlLH FLUE: VEh1 >�•^/ ,TER, M( IO_N`RUN THRU WEB S TJ OU AT ONEXTERIOR FA.,.L FOR ��9 LOCATETHERMOSTAT DrWALL IN OFFICEICE s18A..F. COORDINATE . EXTEFI]R EL VATlON FR l6T.SEEQETAILWP6,C OCOORIDDJNAT W AK lTH : ZONI- SMKE DETECTOR D LOCATION WITH SHEET 3/E3.1 and B/A8.1.STqT10N MOUNT THERMOSTAT HE SENSOR AT 60A ABOVE FINISHED FLOOR ALL TRA DES. _ ..R. t AUDIONISUAL REMO E ALARM STATION NO SCALE r� 00 Cl W f- 0 J n S cel I I 0 r 0 Q0 r -r) O r - V) r_ C) , W W _..J LL. AIR SCOOP EXTRACTOR SUPPLY DUCT ROUND DUCT CONNECTION AIRFLOW t AIRFLOW 'PIN -IN FITTING WITH VOLUME CONTROL DAMPER - INSULATE f0 MATCH DUCT INSULATED SHEET METAL SCREWS MIN. OF (1) EACH QUADRANT AT ALL RIGID PIPE CONNECTIONS. APPLY LOW VELOCITY MASTIC AT ALL JOINTS OF METAL DUCT.-- i ROUND BRANCH l ---- DUCT TO DIFFUSER ITAINLESS STEEL DRAW BAND DR APPROVED EQUAL) IN IETURN AIR PLENUM ADJUSTMENT ROD SPLriiER UAPAPER tiV,� MITERED TEE FITTING r VANES & FRAME DOULBLEWALL TURNING AIRFLOW BRANCH DUC'RVORK NOTES: 1. DOVETAIL S ALL BE MIN. 24 GA WITH DOUBLE G BALANCING C AAPE R 2. FLEXDUCT;;HALL BE C:ERTAINTEED CERTAFLEX OR APPROVED EQUAL, CLASS 1 AIR DUCT UL_ '181 APPROVED. PERFORMANCE CHARACTERISTICS AS FOLLOWS: THERMAL PERFORMANCE: CONDUCTANCE 0=0.18 BTUH/S0,FT.r'F AT 75° MEAN TEMPERATURE. RESISTANCE R==6. FLAME SPREAD INDEX: NOT GREATER THAN 25. SMOKE DEVELOPED INDEX: NOT GREATER THAN 50. STATIC PRESSURE: 1,0" WG POSITIVE, 1-1/2" WG NEGATIVE ALL FLEXIBLE DUCT SHALL BE SUPPORTED IN ACCORDANCE: WITH SMACNA STANDARDS 30 AS NOT TO RESTRICT AIR FLOW NOR CAUSE: EXCESSIVE PRESSURE DROP. LOW VELOCITY DUCT JIL. i VOLUME DAMPE=R RETURN AIR REC IANC ILE TEE WITH TURN RA;LVANES IN EACH SUPPLY DIRECTION ON RY-2 RT -1 DROP REC. ELBOW IN ON DIRECTION -_- INSULATED FLEX DUCT PROVIDE SHORT RADIUS RIGID METAL ELBOW WHERE 18" R. FLEX ELBOW CANNOT BE MAINTAINED SEE FLAN FOR DUCT SIZE - - NOTE: MAXIMUM ALLOWABLE LENGTH OF FLEX DUCT PUNOUTS TO SUPPLY DIFFUSERS = 5'-0'°. FLEX DUCT I S NOT ALLOWED ON EXHAUST, RETURN OR EXPOSES) DUCTWORK. = _ INSTALLER TO SECURE INSULATION TC) PROVE DAMPER HANDLE FOR T&B PERSON THIS HANDLE MUST BE EASILY ACCESSED AND ROTATED FOR AIR � B AIANC;E ADJUSTMENTS. -- -- - STRAP HANGER S i 'II D ,1 / �- SHALL.BE ! IS'T[ D AS YZHW, INSULATION _./ _ - SUBJECT 762 FOLDED BACK �, = ---- ENTIRE 2'X 3/4 Ib. BLANKET OF a SEE HINGE DiAGRAN ON M2 SF -IT. . ANOTAPE D ` ' = INSULATION N//FOIL BACK COVERING, DIFFUSER GRILLE &Boar. ANY,F WR. J ENTILATIGNDAMPER BLADE INSIDI_ DUCT - NYLON STRAP FASTENER (TYP) 24"X24")(1 6" 22 GAUGE SHEET METAL SUPPLY PLENUM (UNLINED) WITH 1 1/2" DUC;TWRAP INSULATION I I SIDE CONNECTION PERFORATED SUPPLY AIR DIFFUSER- - RE: AIR DEVICE SCHEDULE ri L NO -1 ALL Cour 18 GA. GA 4 101 L F-- tZ W W t: GENERAL NOTES i. Exhaust and supply duct collars may be field cut. 2. Exhaust duct air flow velocity shall be between 1500 and 2200 FPM 3. Exhaust and supply air flours must be balanced upon installaffon. Fan operating speed should be rechecked after 60 days to ensure proper performance. Static pressure values are given for the hood only and do HOOD # LENGTH (IN): `1 OF 2 MODEL # , 11'-0" WIDTH'(IN). a8HEIGfTT (IN) SV NQ 2a' HOOD .# L NC#TIi {IN);. 2 OF 2 MODEL # 1(7' 0" WIDTH {INj; 48," ,HEIGI-rf'(IN); SV 24" EXHAUST CFM: 2200 SUPPt:.Y CFM:. NA EXHAUST CFM. � 2000 :SUPPLY CFIvt: NA E..XHAU:3T SP; -1.5 SUPPLY, 5P; NA EXHAUST SP 1.0 SUP_ PLY SP: ._.�. EXHAU:3T FPM; 1684 SUPPLY'FPM: NA EXI-MUST F�?M; 1600 .SUPPLY FPM; ►yp EXH. SIZE:. 20"X'}0" S.UP SIZE; NA E;<H. SIDE; 18"x '10' 'SatJP SIZE: -... -- -- NA FILTERS: (2}. 16"k-16" 16" FILTERS: (6) I6" X 2Q" F1LT FIS; {f2) , 16' K 16' FILTFtS: () FIRE SUPPRESSION: AN31.4-8102 FILTER TYPE; ALUMINUM FORE $UPPFII SSIGN; ANSUL-R 102 FILTER TYPE: ALUMINUM LIGHT CITY: (3) IN` CANDESCENT CONTROL SWITCH: NONE LIGHT OTY: (3) ' INCANDESCENT K:f)NTROL SWTTGN:� N _Tr, ,,,ti -'j-, � r.: ,,,r.:u. ti SPECIFICATIONS 48�.a.'�I24 FAX 2 1. Floods shalt be constructed of 18 gaugestainlesssteel with # 3 r.6 •" S06 8 Ot?i19 004432: polish, All unexposed surfaces shall be constructed of minimum p ...., 18 gauge aluminized steel. t HOODS ARE SUPPORTED "Y w J BOX PRE -WIRED TO E E� 1/2 2. Supply plenum shall be lined with foil backed insul�ttiort to prevent n �, l THREAQED R(7D " PP Y s I LI . HTS INSIDE OF�HOOD. condensation. 1' 6" 1 Q THrJEAE)ED NroQ SUPPORT 3 UL classified aluminum or stainless steel baffle -type filters shall be tYp • � �� ' easily, removed for cleaning. Filter hauling shat( terminate in a pitched f41GUNTlNGBRA. KE:T4 T'r'P. removable grease trough that drains into a removable stainfesy steel ( ); grease cup.------ - 4. UL listed and NSF approved vapor proof InCandesc;ent light fixtures erre- AWE Q ES . ` - :- wired to junction box at top of hood in accordance with NEC 70, - ----r---- -- ---- - =L--- r ENGINEER-PE'04065 5. Hoocls(s) shall be equipped with fire damper fitted to supply duct collar. JAC Klt.PA USH��. ARCHITECCT'=AR'2t308 -` - 6. Pre -piped fire suppression systems shall be located on the top of the hood Location may vary with each individual system. . FUTURE OVEN 7. Hood(s) shall be fabricated in accordance with NFPA Bulletin #96 and .�_ LEFT HAND = = = - -' - n shall bear the NSF Suri of Approval. Hoods shalt be listed und�3r UL 710 1 eat > REMOVABLE I r� �j 4. --t { � I r 1 EXHAUST HOODS FOR COMMERCIAL COOKING EQUIPMf NT UL File ii' MH18853. END..SKIR.r I I I`' i I IIS _r1I - II F I i} l I I P1O MEiUS"fAE3LE r lui_ Ilr 1 (U 11- II 1 1 y`lALL O 21.1 C (- -I _ I i r I r l us A'A I '_r �L III Il,}ftlZEE FF� ►11 I _ _ 1 FF Ir r= . _ If THIS HOOD DESIGN IS BASED UPON I �= II i I =4C= I fIII�III 'II II STRATO VENT. MANUFACTURED BY:Lift- 11 Ill 1 CiENERALVENTIEA'rION, L.L.C. _-'� __ 1.l. > 69 T"AMM`( LI M'LE D,111VE (HIGHWAY 35) / � SECTION, ALABAMA 35771 - 270"L X 116"H STAINLESS STEEL BACKS PLASH.COVERING THE " TM r�� � a4 L X 11,6"H STAINLESS VE EL; PHONE 256.228.4757 WALL BEHIrNU THE: HOOD AND 18' LEFT. r �tIGH r WALL PANEL, AOO OT AND PECIS ffypj N.T.S. � I f YA I y , ,�. rl / I ST ' -ORE NUM6 ,, , 1. 352900 ROD ,AMEN IC,I !: I (7) co rD rD --.I (Li Ljj I— E- 0 1 EL L Job Name: KFC Drawn by: System Size: ANSUL-3.0/3.0/`,3,0 Total FP required: 26 (33 MAX). Flood 1: 11' U' long x 48" Wide x 24" High Rlser ! 'I Sve: 10" x 20"10=0 111-01, Flood # 2: -10'0" Long x 48" Wide x 24" High - KFC HOOD # 1 KF?G HOOD # 2 Riser # 2 Size: 10" x 18"� � , NOTES �PIELU PIPE DROPS AS SHOWN SLEEVING, ELBOWS, TEES, AND NOZZLES SUPPLIED BY STRATO-VENT RELOCATE NOZZLES IF FLOW PATTERN IS BLOCKED BY SHELVING, SALAMANDERS, ETC. MAXIMUM 9 ELBOWS IN SUPPLY LINE. - MININIUM 72 INCHES OFAGENT LINE FROM TANK TO FIRST 11OZZLE. IF APPLICABLE, PRE -PIPED CHARBROILER DROPS ARE SHIPPED LOOSE, FACTORY PIPING EXTENDS A MAXIMUM OF E ABOVE THE TOP OF THE HOOD. - APPLIANCE DIMENSIONS LISTED REPRESENT THE COOK SURFACE SIZE, NOT THE OVERALL APPLIANCE SIZE. THIS FIRE SYSTEM COMPLIES WITH U.L. 300 REQUIREMENTS FACTORY PIPING; �J i`i5 Y ' ed 9�.:C �- _ _ ----- FIELD PIPING co p[['� ( �a C�15 rx LL I rQ v y ;- �� JE' (' In � _ �^ �I 0 If1 � '=UI'1I ��� ([ BUSS ti'111:0 MEIMBEH NUT & WASHER TOP & BOTTOM -1i x4', E3LUC;K ;2 1300 !4 L0,"ATICNS) H2.5 EACH SIDE 2'x6' TRUSS BTfY CORD 112' 0A Al.,L THIJ EAD ROD DRILL I i- E [HRU BLOCK C 1 - ROD ATTACHME.Wr 13 � - ] Nmmm NIJT H _0 MO JN1 1h' 0( "1 ­HAI'�NEL C"I W)OD r. BOLT CONNECTION TO H0101) >i I$ BAHDIN'o- 304 SS '�Ij X .014" -T HICK tJIN 3,1 MIN, L0NGIT,,),Dft11L A%,�Z­ OVERLAP AT 81,ANKE -T JOINT 3" MIf1, PEHIME 'ER OVERLAP AT 81-41KETJOIN T LJYER 1 1/2'' THIC'/, 8-11"P F1-iEIVIASTE'r-} E cc,!,,TiNUOUSLY WF1 DED HOOD EXHAUST DUCT =� ' ? G 112' M".) rES D UC ),NTI1 I�P C', S N�UOUS 4S, FF;OM : Fr - - r 0 M '-' 0 N N E CTJ �_" f,J A I -IROUGH _URF 10-112" 21'i'YP IVR, iEA, AND EXTEND '13" BELOtili ROOF DE(,,K, BANDIN"'.'j, REOUIREMENT3. USE 304 S EAIH'!_E'S5 81-F E-1 2, F : -)R HORIZONTAL HUN'S OF EXHAUST DUCTS PRCY-v'IDE BAIIIDS "\ MAXIMUM 1-1/2 FROPl BLANKE r EDGE= AND TYPICAL. RAPL1EF)uPr­oF:I r SYSTEM WITH 1/:)HAN'GEPROSY ", SPACED A MAXIMUM OF 10-1/2 ON CEEN711RA I'vIAXINIUM OP 6' ;HOM INSULATION E0,' 1E 'I RAPLZES'UPP(')HTS SHALL BE SPACED A MAXIMUM OF 60" 01NI ("E."ITER C'E"N IE'RUNE OF VERTICAL EXHAUST DUCT. 3 SLOPE I-,iOR{Z',)NTA1_ EXHAUST DUCT Ri;NS A MINIMUM OF 14 E'ER f -'- )O I' ;2% SLOPE; TOV-iARDS EXH,"UST HOOD. 4. PrPOVIDE INSULATED AC,,ES!3 DOOR OPPANr__'L NEAR MWD P'1_11INT C')F EXHAUST DUCT HUN FOP GLEANING AND INSPECT1011 Or DUCT PPOVIDE AN �PPRCVED SIGN ON ACCESS D(I)OR (-.)R PANEL' /40-i READS ACCE,"-S PANEL F_',G 11r IT OBSTRU r, KITCHEN 1400D EXHAUST DUCT S"fit STU11 DETAIL. �J T,> I � �fi . ........... .3 AIR 15� OR LF -33 B Aill Z' 01-{ LES 51 FLO ORMA,r�om EXPANSION R ` : - VANEZ, TURNING VAN F, 'IRFE i ,, r` t+:J" ITUWHING VANES TURNING VANES 90; ELBOW 45" ELDO* SIMILAR NO _�HROAT RADI(JS, SHORT FiADIJS L 3A D E--- 90' ELE1001AKE-OFF b� ... J . ..... IUS E 0 N LY I i'l AREAS RETURN AIR BRANCH RAE) 'LDO�%� SUPP; Y OR RE -URN 1,'T(E FITI"ING PU LL RADIUS I/ H i R E ") P A C �RECTANGULAR DU -'*"T) -------- TAKE -OF -F �ry'pmll. DUCTWORK DETAILISD T.s____Fi RETURN AIR DUCT si-*NsoR sTP,NDOFP BRACKET S+._ AL S. -AL DU(,T PENE-RATION AIR TIG'- I To,rHc'_:F3NI('.):.')TAT RC,MO'fF HUMIDITY SEI'TSOR RI -MOVABLE: RETURN "'RILLE REMOTE HUMIDITY SENSOR 3,,,8;'- "-()- 1 9 KITCHEN HOOD [':':XHAIJST FAN 110" M IN 3 IS(;HARGE HEIGHT NEMA 3R DISCONNECT FACTORY WIRED FROM MOTOR TO DISCONNEC r TH ROUGH TH E BREATHER TUBE NOTE: 'a. OCA,rE EXHAUST FANS MIN. IU -0" _'T F OM ANY OUTSIDE AIR INTAKE CK JI I I J Fl E-FIROOF INSULATION GROOLUP LIQUID TIGHT FLEXIBLIECONDUIT M F-21 0 M. " Ir M engineenng*architecturo aplanning L VENTED CURB EXTENSION 16500 NEW BARN ROAD < SUITE 106 < MIN. 16" GA. WELDED I -EXHAUST NOTE: F_I L.IC DUCT -EXTEND MIN. OF 18" XMIAMI LAKES FLORIDA 33014 , -R NFPA ABOVE ROOF DECK PE PHONE: (32�5568-4-124 ' ROOF FAX. ..(305) 826-06-il 19 9 PREFABRICATED GAL\/. STEEL E8#0004.432 H CURB WITH INSULATION. GREASE TRAP 6. J NOTUSEI) N T 15� EXHAUST FAN N33. 71 - LC)\V VELOCI_'( DUCT SEAL STRAP HANG;ER _10SENECK VAN(*.;E OAKF:S ------- INAECH. ENGINEER PE 54065 JACK D. RAUDENBUSH STRAP FASTENIER (1'(Pl, I I r..r ' 24'x24"y 16" 2,- GAUGE SHEET METAL ARCHITECT -AR 2808 4, SUPPLY PLENUM (UNLINED) WITIH LIZ 1 '/2" DUCT *RAP INSULATION --7 INSU�_ATEU` FLEX 0U(1,'T - Pl`.'QVID'E BUG-SC"REF N—\ FO, I W—? F RADIUS METAL ;24 ELB(A'i \,','HERP' 18' R FLEX ELB,',)'vV _/ / --� CANHOIT BE MAINTANIE"D S ')R CE: FLAN .N F(' DU(, F S_ 12- NOTr". OURO -LAST ROOFING MEMBRANE VIAXII`,1UM ALL( _,'0/AB..rE LENGTH OF F- i X r "?UN',_,"JTS, V),S,JPPL ( DIF, USERS = 0". FLEX DUCT IS NI-I'T Al­!_Q�^il__.'D Olk EXI-iAUS"I RETURN JR L' XPO�;ED DIJIC h',iORK _31DE: CONNECTION PERFORATED SUPPLY AIR DiFFU>ER PE AIR DE\/ICF,`:;CHE`DULE -- ------------- KIT(J"IHEN AREA CE.ILINU41 DIFFUIDER CONNECTION DEJ'AlL N T 6; ­------­--------- 3ASK J ET 15"ENTRY' CLINCHED COLLAR TRANSITION TO ROUND SEE PLj\N3 FORSIZE AVHEHE 0(.,,r,URS,,i BRANCH E)UCT. RECTANGULAR OR HOUND BUTT-ERFLY DAMPER tiVITH ARM & LOCKING (DUADRANT,TYPICAL; — ------ -- ----- — ----- INSULATED FLEX DUC'T - PROVIDE I SHORT RADIUS RIGID METAL I ELBOW WHERE 18" R FLEX ELBOW i LOW VELOC11Y ouc,r CANNOT BE MAINTAINED STRAP HANGER NYLC'N STRAP FASTENER (1 TYP) I 1/2'OUCT'NRAP INSULATION NOTE: MAXIM M ALL'-' P-\F3LEL-F:NG'Tr-IOi-:FLE:Y\'DU(:'F TOP CONN E-CTION Rt'11,10UTG TC SUPPLY DIFFUSERS = 14',0' FLEX DUCT IS NOTALLO"NED ON FXPOSED CONNECTION Cy"MILING Off"FUSER 1(,*W'01MNECT10NS 3,,81, -1 --01 NoTt", ALL COUN-rERFL.ASHII\:IG DRIP SHIELD AND EXPOSED DUCTWORK SHALL BE' 18 GA. GAL.VANI?ED SHEETMETAL ALL SOLDERED AIR -TIGHT CONSTRUCTION. GOOSENECK FOR EXHUASTFAN N.TS. 2 GENERAL NOTEISO 1. Exhaust and SLIPPly duct collars may be field cut. 2. Exhaust duct air flow velocity shall be between 'l 500 and 2200 FPi\/I. 3. Exhaust and supply air flows must be balanced upon installation. Fan operating *;peed should be rechecked after 60 days to ensure prop performance. 'Static pressure values are given for the hood only and do not inclucie ductwork. and rooftop fans. 41 1 '05PECIFICAT 10MIS 1, Hoods shall be constructed of 18 gauge stainlev; steel with # 3 polish, All unexposed surfaces shall be constructed of minimum l8 gauge, aluminized steel. 2 Supply plenurn shall be lined with foil backed insulation to priavent condensation. 3 UL classified alurninurn or stainless steel baffle -type filtrars shall be easily removed for cleaning, After housing shall WrmInate in a pitched removablegrease trough that drains into a removable stainless steel grease cup. 4. UL listed -and NSF approved vapor prt)of Incandescent light fixtures pre- wired to junction box at top of hood in accordance with NEC 70. 5 Hoods(s) shall be equipped with fire damper fitted to Supply duct collar. 6- Pro -piped fire Suppression systems shall be located on the top of the hood Location may vary with each individual system. Z CONTRACT DATE: XX.XX.XX BUILDING "TYPE: K -y07 PLAN VERSION, 2007-D SITE NUMBER 297909 STORE NUMBER: 362900 KFC, 3601 ORLANDO DRIVE SANFORD, FLOR10A 7 Hood(s) shall be fabricated in accordance with NFPA Bulletin #96 and K -Y07 shall bear the NSF Seal of Approval. Floods shall be listed under UL 710 EXHAUST' HOODS FOR COMNIERCIAL COOKING EQUIPMEENT UL File # MH1 8853, M Ef (w" H A J h1*42 1 (0 114iAL PTO], a NAft EMIL NAPA' AND nuou THIS HOOD DESIGN IS BASED UP6N 10E."TAIL's STRATO VENT, MANUFACTURED BY: GENERAL, VENTILATION, L.L.C. 5759TMiIMY LITTLE DRIVE (HIGHWAY 35) SECTION, ALABAMA 35771 'fil4almiO PHONE 256.228 4757 PLOT DATE 10,19.07 HOOD NOTIES AND SPECT (wo.j.) 4 1. SOIL AND WASTE PIPE SHALL SLOPE 2% MINIMUM, UNLESS OTHERWISE NOTED OR REQUIRED BY CODE. 2. ALL DRAWN WATER ,& GAS LINES SHALL BE KEPT TIGHT TO THE UNDERSIDE OF EQUIPMENT & SECURED IN PLACE. 3, CONTRACTOR SHALL VERIFY THE LOCATION OF THE SANITARY SEWER ON THE SITE PLAN AND SHALL REVISE THE SEWER SYSTEM AS REQUIRED. 4, PROVIDE TRAP PRIMERS FOR FLOOR DRAINS IN RESTROOMS, WHERE REQUIRED BY CODES, PROVIDE DEEP SEAL "TRAPS FOR FLOOR DRAINS WITHOUT TRAP PRIMERS, 5, ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE, THE CONTRACTOR SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT, CABINETS, ETC, AND THE OWNERS REPRESENTATIVE PRIOR TO ANY INSTALLATION, 6. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTORS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON -ACCESSIBLE CEILING SHALL BE INSTALLED BEHIND AN ACCESS PANEL, 7. ALL PLUMBING FIXTURE VENTS SHALL TERMINATE A MINIMUM OF 12 INCHES FROM ANY VERTICAL SURFACE AND 10 FEET FROM ANY OUTSIDE AIR INTAKE. 8, PROVIDE GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION 9. INSTALL SHUT-OFF VALVES ON ALL HOT & COLD WATER LINES TO FIXTURE OR APPLIANCE ALL EXPOSED WATER AND WASTE LINES TO BE CHROME PLATED. 10. PROVIDE A LEVER HANDLE GAS SHUT-OFF VALVE IN THE BRANCH PIPING OF EACH APPLIANCE OR PIECE OF EQUIPMENT, FOR EACH APPLIANCE INSTALL QUICK DISCONNECT, FLEXIBLE PIPE WHEN ALLOWED BY CODE AND RESTRAINING DEVICE FURNISHED BY OWNER, PROVIDE PRESSURE REDUCING VALVES AT EACH PIECE OF EQUIPMENT OR APPLIANCE, IF GAS PRESSURE GREATER THAN '1077 IS USED DOWNSTREAM FROM THE GAS METER. 11. ALL VALVES, UNIONS, ETC. SHALL BE SAME SIZE AS PIPE UNLESS OTHERWISE INDICATED ON DRAWINGS 12. REFER TO KITCHEN EQUIPMENT DRAWINGS FOR PLUMBING ROUGH -IN SCHEDULE & FOR ADDITIONAL WORK TO BE FURNISHED & INSTALLED BY CONTRACTOR, ALL ROUGH -IN PLUMBING AND FINAL CONNECTIONS TO KITCHEN EQUIPMENT SHALL BE MADE BY THE CONTRACTOR U,O,N, 13. REFER TO MECHANICAL SHEETS FOR HVAC AND HOOD PLUMBING REQUIREMENTS. 14. ALL GAS LINES SHALL BE SUPPORTED SEE SPECS. 15, ALL FLOOR SINKS AND FLOOR DRAINS IN TRAFFIC AREAS SHALL BE INSTALLED FLUSH TO FLOOR SURFACE, 16. PROVIDE WATER HAMMER ARRESTOR FOR ALL HAND SINKS AND URINAL WATER LINES. 17. PROVIDE AIR GAPS FOR INDIRECT DRAINS AS REQUIRED BY CODE, AIR GAP SHALL BE MINIMUM 2 TIMES THE DIAMETER OF THE INDIRECT DRAIN. '18. PRIOR TO COMMENCING WORK ON THIS PROJECT, VERIFY DEPTH, SIZE, LOCATION AND CONDITION OF ALL EXISTING UTILITIES IN FIELD, SHOULD CONDITIONS EXIST OTHER THAN THOSE INDICATED WHICH WOULD CAUSE THE DESIGN TO BE ALTERED, CONTRACTOR SHALL NOTIFY OWNER IMMEDIATELY. '19, COORDINATE INSTALLATION OF PLUMBING WORK WITH ALL OTHER TRADES SO AS TO AVOID UNNECESSARY DELAY OR INTERFERENCES, CONTRACTOR SHALL REVIEW ARCHITECTURAL AND EQUIPMENT SHEETS, 20. FURNISH & INSTALL ALL BACKFLOW PROTECTION DEVICES REQUIRED BY AGENCIES HAVING JURISDICTION. BACKFLOW DEVICES REQUIRING TESTING SHALL BE INSTALLED NO HIGHER THAN 6-0` A.F.F. 21. PROVIDE CONDENSATE DRAIN FROM A/C UNITS TO APPROVED DRAIN, GAS PIPING TO UNITS AND ALL FINAL CONNECTIONS REQUIRED FOR OPERATION, 22. THE OWNER OR KITCHEN EQUIPMENT SUPPLIER MAY SUBSTITUTE EQUIPMENT OR THE EQUIPMENT MAY VARY FROM WHAT IS SHOWN, THEREFORE, VERIFY ALL CRITICAL DIMENSIONS WITH THE OWNER PRIOR TO CONSTRUCTION, FAILURE TO VERIFY THESE DIMENSIONS SHALL PLACE THE RESPONSIBILITY FOR ANY SUBSEQUENT RELOCATION DIRECTLY UPON THE CONTRACTOR, 23. ALL WATER LINES SHALL BE RUN OVERHEAD U.O.N. 24. ALL WATER LINES SHALL BE FLUSHED PRIOR TO CONNECTING ANY FIXTURES OR EQUIPMENT. 25. PROVIDE ESCUTCHEON PLATES AND SEALANTS AT ALL UTILITY PENETRATIONS INTO WALLS, CEILINGS, AND FLOORS, DO NOT USE CAULKS OR EXPANDING FOAM FOR SEALANTS. GENERAL NOTES I n PLUMBING SCHEDULE CK GROUP INCORPORATED engineering • architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 z� 0 0 0 0 CONTRACT DATE: ITEM FIXTURE SOIL OR WASTE VENT COLD WATER HOT WATER TEMP'D WATER WASTE FU WATER FU DESCRIPTION 3-11-2008 MANUFACTURER / MODEL NUMBER ECO1 EXTERIOR CLEANOUT CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER, JOSAM / MODEL: 56000 WADE / MODEL: 6000Z ZURN / MODEL: Z-11100 FS 1 FLOOR SINK 4" 2" g PVC 12" SQUARE FLOOR SINK, 8" DEEP, WITH ALUMINUM OR PVC DOME STRAINER AND LOOSE SET PVC SLOTTED TOP GRATE. SET FLOOR SINK LIP FLUSH WITH FLOOR TILE, JOSAM / MODEL: JPF84-PVC ZURN / MODEL: FD-2370-PV4-DS-F FD 1 FLOOR DRAIN 3" 2" 2 - PVC FLOOR DRAIN, 5" DIA. IF PVC OR ABS DRAINS ARE USED, SCHEDULE 80 PVC DRAIN PIPE SHALL BE USED FOR THE FIRST 10'-0" FROM THE DRAIN ZURN /MODEL: FD -2210 JOSAM /MODEL: 30003 A WADE / MODEL: 1103 HD 1 HUB DRAIN 3" 2" 2 CAST IRON DEEP SEAL P=TRAP WITH FUNNEL, NO -HUB OUTLET AND BRASS GASKETED CLEANOUT PLUG. JOSAIVI / MODEL: 88213 WADE/ MODEL: 2453EF ZURN / MODEL: Z-1019 FCO 1 FLOOR CLEANOUT -- - -- CAST IRON CLEANOUT WITH THREADED ADJUSTABLE HOUSING, ROUND SCORIATED HEAVY CAST IRON COVER. JOSAM / MODEL: 56000 WADE/ MODEL: 60002 ZURN / MODEL: Z-1100 CO 1 WALL CLEANOUT - CAST IRON CLEANOUT TEE WITH INLET/OUTLET SPIGOT AND THREADED BRASS PLUG, WITH STAINLESS STEEL ACCESS COVER, JOSAM / MODEL: 58510 -WADE/ MODEL: 8560E ZURN /MODEL: Z -11146 -BP HB 1 HOSE BIBB - 3/4" 2.5/1 FREEZELESS WALL FAUCET WITH INTEGRAL VACUUM BREAKER, BRONZE CASING MAX PRESSURE OF '125 PSI, SLOPE HOSE BIBB TO DRAIN TO EXTERIOR, INSULATE PIPES IN WALL WOODFORD / MODEL: 19 (WC =l WATER CLOSET 2" 'I/2" 4 2 WHITE VITREOUS CHINA FLOOR MOUNTED FLUSHOMETER TANK (PRESSURE ASSISTED) TYPE, ELONGATED BOWL, ADA COMPLIANT, '1.6 GPF, WITH OPEN FRONT SEAT LESS COVER, OLSENITE #95 OR EQUIVALENT, FLUSHOMETER TANK: SLOAN FLLUSHMATE OR EQUAL. PROVIDE TANK COVER LOCKS, FLUSH VALVES SHALL BE RIGHT HAND OR LEFT HAND AS REQUIRED TO CORRESPOND WITH ACCESS FROM WIDE SIDE OF STALL. VERIFY FLUSH SIDE REQUIREMENTS AM. STD, "CADET"/ MODEL: 3109.016/4098.800 KOHLER "HIGHLINE" /MODEL: K -3544-T CRANE "ECONMISER" / MODEL: 3H839 L 1 LAVATORY '1 'I/4" 1 1/2" I/2" 1 1.5 WHITE VITREOUS CHINA, WALL HUNG=,, WITH CONCEALED ARMS SUPPORT, 4" CENTERS, WITH INTEGRAL BACKSPLASH, ADA ACCESSIBLE, FLAT GRID STRAINER. FAUCET: FURNISHED BY OWNER -INSTALLED BY G.C. SINGLE LEVER TYPE FAUCET, ADA COMPLIANT,DELTA MODEL: #500. SEE 8/P6.0 FOR LAV SUPPORT DETAIL. A.S. LUCERNE/ MODEL: 0355.012 KOHLER KINGSTON / MODEL: K-2005 CRANE "HARWICH" / MODEL: 1412V S 1 HAND SINK 1-1/2" 1-1/2" 1/2"2 1.5 S-1: STAINLESS STEEL HAND SINK, WALL HUNG, INCLUDES A 6" GOOSENECK STAINLESS. FAUCET W/FOOT VALVE PER DETAIL 7/P6,0. S 2 MOP SINK 3" 2" 1/2" I/2" ;3 AERO MANUFACTURED MOP SINK, 31VIP212I& 2.25 24" x 24" x 10", FURNISHED WITH WALL PANELS, - S 3 3 -COMP. SINK INDIRECT '1/2" 1/2" SINK, FAUCET, DRAIN & PRE -RINSE KIT 3 S 4 PREP SINK INDIRECT 1/2" I/2" SINK, FAUCET AND DRAIN 3 -- - C61—M GREASE INTERCEPTOR 6" -- -- -- -- -- PROVIDE 1,000 GALLON GREASE INTERCEPTOR OR SIZE AS REQUIRED BY AHJ, SEE CIVIL PLAN FOR EXTERIOR GREASE INTERCEPTOR SIZE AND LOCATION. MV 1 MIXING VALVE - 1/2" 1/2" THERMOSTATIC, 125 P516, 200VF BRONZE BODY, STAINLESS STEEL PISTON LINER, CHECK VALVES SIZE PER PIPE CONNECTIONS, HYDROTEK SERIES HBL LAWLER SERIES 61 LEONARD SERIES 210 WH 1 WATER HEATER 1-1/4" -1.1/4" - GAS FIRED WATER HEATER, 98.5% THERMAL EFF., 199,000 BTUH INPUT, '100 GAL. STORAGE TANK, 239 GPH @ 100 DEG. RISE REC, RATE, 3" PVC FLUE &AIR INTAKE, ASME RTD TEMP. & PRESS. REL, VALVE, ELECTRONIC IGNITION SYSTEM, ELETRONIC CONTROLS AND INTEGRAL DIAGNOSTICS, BRADFORD WHITE/ EF-100T-199E-3N(A) - WATTS SERIES DET ET 1 EXPANSION TANK 3/4" EXPANSION TANK, STEEL, EXPANSION MEMBRANE '150 PSI, 160° F, '12 GALLON CAPACITY. MOUNT EXPANSION TANK WITH CHECK & SHUT OFF VALVES ABOVE WATER HEATER, AMTROL SERIES CST WILKINS SERIES WXTP BFP 1 BACKFLOW PREVENTOR VERIFY REDUCED PRESSURE ZONE BACKFLOW PREVENTER, CAST BRONZE CONSTRUCTION WITH 1 QUARTER TURN FULL -POR "f BALL VALVES AND BRONZE STRAINER. WATTS / MODEL: 009M20TS WILKINS / MODEL: 975XLS FEBCO / MODEL: 860 SA 1 SHOCK ARRESTOR -- '1/2" - STAINLESS STEEL CASING, WITH STAINLESS STEEL BELOW, PRECHARGED WITH NITROGEN SIZED PER PDI-WH2O1 WADE / SHOKSTOP JOSAM / MODEL: 75000 ZURN / SHOKTROL PLUMBING SCHEDULE CK GROUP INCORPORATED engineering • architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 z� 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 AND NOTES PLOT DATE: 2008 A. NO ROOF PENETRATIONS PERMITTED WITHIN ROOF WATER PLY. REFER TO ROOF PLAN FOR LOCATIONS. B. REFER TO RISER DIAGRAM ON SHEET P5.0 FOR ALL WASTE AND VENT SIZES, C. STORM WATER PIPING IS SIZED FOR A RAINFALL OF 4" PER HOUR. ADJUST ROOF DRAIN (RD -1) SIZE AND STORM PIPE SIZES PER THE LOCAL RAINFALL REQUIREMENTS AND BY THE AUTHORITY HAVING JURISDICTION. PIPE SHALL DISCHARGE -OVER DRIVE-THRU ROADWAY CURB OR AS DIRECTED BY THE AUTHORITY HAVING JURISDICTION. D. INSULATE ALL HORIZONTAL RUNS OF STORM DRAINAGE PIPING ABOVE THE CEILING OR EXPOSED WITH 1" CLOSED CELLULAR INSULATION WITH VAPOR BARRIER JACKET THAT CAN BE PAINTED. E. 4" SECONDARY DRAIN OUTLET SHALL EXTEND 2" BEYOND FINISHED WALL. SEE ARCHITECTURAL DRAWING A4.0 FOR INSTALLATION PROCEDURE AND A4.1 FOR EXACT LOCATION OF DRAIN OUTLET, F. COORDINATE LOCATION OF STORM WATER PIPING ABOVE CEILING WITH ALL TRADES PRIOR TO INSTALLATION. WASTE & VENT PLAN NOTES n Q PROVIDE FLOOR SINK, IN LIEU OF HUB DRAIN, IF REQUIRED BY LOCAL CODE, PROVIDE CONDENSATE LINE AND DRAIN LINE FROM ICE MACHINE TO HD / FS, PROVIDE AIR GAP PER LOCAL CODE. WASTE & VENT PLAN 1/4"=1'-0" 11 RUN DRAIN LINE FROM S/S DRINK MACHINE THRU WALL OP'G. TO OUTFALL AT FS BENEATH D/T DRINK MACHINE.. 12 UNDERGROUND SANITARY PIPE SHALL BE NO HUB CAST IRON FOR THE FIRST 10 FEET FROM CONNECTION TO FLOOR SINK FS -2. Q PROVIDE WASTE LINES FROM BEVERAGE UNIT TO HD / FS, PROVIDE AIR GAP PER LOCAL BUILDING TYPE: K -y07 PLAN VERSION: CODE, 13 NOT USED Q PROVIDE 3/4" PVC OR COPPER CONDENSATE FROM DRAIN PROVIDED BY VENDOR TO 14 WATER HEATER CONDENSATE. SEE DETAIL 2/P6.0, RUN INSIDE WALL AND OUTFALL AT MOP SINK/HUB DRAIN (HEAT ROPE IS SUPPLIED WITH FREEZER CONDENSATE). EXPOSED PORTION OF CONDENSATE SHALL BE COPPER. 15 4" ROOF LEADER DOWN FROM ROOF DRAIN. INSULATE ALL HORIZONTAL 5 PVC OR COPPER CONDENSATE DRAIN FROM HVAC UNITS ON ROOF, RUN ABOVE RUNS OF STORM DRAINAGE PIPING. CEILING TO MOP SINK. PIPING SHALL SLOPE 1/4" PER FOOT AND SHALL BE INSULATED WITH 1" CLOSED CELLULAR INSULATION. REFER TO RISER DIAGRAM ON SHEET P5.0 FOR 16 4" STORM DRAIN PIPE DOWN IN WALL PIPE SIZES. Q ENTIRE RUN OF DRAIN LINES TO INLET OF EXTERIOR GREASE INTERCEPTOR AND OUTLET OF INTERCEPTOR TO CONNECTION AT SANITARY MAIN SHALL BE SCHEDULE 40 PVC DWV OR AS REQUIRED BY THE AUTHORITY HAVING JURISDICTION. O NOT USED ® 4" VENT UP THROUGH ROOF, COORDINATE W/ STRUCTURAL. PIPE 3 -COMPARTMENT SINK TO FLOOR SINK WITH AIR GAP PER CODE, 10 NOT USED 7m_ al-11- OROUP INCORPORATED engineering • architecture *planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 E B #0004432 uo(� SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 U 6-18-08 CITY -UTILITY DEPT, L 0 A A CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 PLOT DATE: 2008 1 1/4" DOMESTIC WATER SERVICE, FOR CONTINUATION, SEE CIVIL DRAWINGS, A, WATER DISTRIBUTION PIPING IS SHOWN ABOVE FINISH CEILING. UNDER SLAB DISTRIBUTION ALLOWED AT CONTRACTOR OPTION, COORDINATE ALL DETAILS, B. NO ROOF PENETRATIONS PERMITTED WITHIN THE ROOF "WATER VALLEYS", REFER TO ROOF PLAN FOR LOCATIONS, C. REFER TO SHT P4.0 FOR ROUGH -IN LOCATIONS, D. REFER TO SHEET P5.0 FOR WATER AND GAS ISOMETRIC DRAWINGS. WATER &GAS PLAN NOTES Fo I Q NOT USED 1 1/4" GAS DOWN TO WATER HEATER WITH GAS COCK, DIRT LEG AND UNION Q 1/2" TEMPERED WATER DOWN IN WALL TO HAND SINK. �J I" HOT AND I" COLD WATER LINES TO WATER HEATER. 1/2" HOT AND COLD WATER LINES DOWN IN WALL TO PREP SINK. 1/2" HOT AND COLD WATER LINES DOWN IN WALL TO THREE COMPARTMENT SINK. 1/2" FILTERED WATER DOWN IN WALL TO BELOW SLAB. DO NOT INSTALL ANY JOINTS BELOW SLAB, I, BRACKETS, CO. SEE WATER & GAS PLAN 1/4"=1'-0" 15 1/21' CW DOWN IN WALL TO EXTERIOR HOSE BIBB. 16 BUNDLED SYRUP LINES TO BEVERAGE DISPENSERS S-532 & 5-533 AND FILTERED WATER LINES TO ICE MAKERS S-511. SEE DRAWINGS A2.0, P5,0 AND P6.0. 17 1/2" FILTERED WATER DOWN IN WALL TO BUNN HOT WATER DISPENSER P-721. 18 2 1/2" CAS DOWN ALONG WALL TO KFC COOKING EQUIPMENT, lg 2" GAS MANIFOLD ALONG WALL TO TB COOKING EQUIPMENT. 20D -1/2" FILTER WATER STUB -UP FROM BELOW SLAB TO 1" A.F,F, FOR CONNECTION TO T HEATED DISPLAY UNIT P-001, 21) 3" PVC EXHAUST AND INTAKE FLUES FROM WATER HEATER, PIPE INTAKE THRU ROOF AND 1/2" COLD AND HOT WATER DOWN IN THE WALL TO THE MOP SINK. EXHAUST THRU REAR WALL AS RECOMMENDED BY MANUFACTURER. SEE SHEET M2,0 Q 1/2" CW DOWN IN WALL TO WATER CLOSET FLUSHOMETER TANK, AND DETAIL 2/P6.0. c 1" GAS CONNECTION TO FRYER. PROVIDE FLEXIBLE HOSE KITAS INDICATED ON 10 REDUCED PRESSURE BACKFLOW PREVENTER LOCATED ABOVE THE CEILING IF ALLOWED ARCHITECTUAL DRAWING A2, 1, BY LOCAL UTILITY. PROVIDE SHUT-OFF VALVES AT BOTH SIDES OF BACKFLOW PREVENTER. PIPE RELIEF TO HUB DRAIN. VERIFY LOCATIONS WITH CIVIL DWGS. VERIFY 23 1" GAS CONNECTION TO EACH PRESSURE FRYER, 1 1/4" GAS CONNECTION TO 6 HEAD WATER SERVICE REQUIREMENTS WITH CITY. FRYER AND 1 1/2" GAS CONNECTION TO DUAL FRYER. PROVIDE FLEXIBLE HOSE KIT AS 11 1/2" TEMPERED WATER LINES DOWN IN WALL TO LAVATORY. 12 3/4" CW DOWN TO WATER FILTER. 13 1/2" FW FROM WATER FILTER S-592 TO P-001 & P-451.FILTERED WATER CONNECTION AFTER SECOND WATER FILTER. SEE RISER DIAGRAM ON DRAWING P5,0, C4D 1/2" CW DOWN IN WALL TO WATER CLOSET FLUSH VALVE & R.O. SYSTEM, INDICATED ON ARCHITECTUAL DRAWING A2,1. 24 EMERGENCY CTAS SHUT-OFF VALVE LOCATED BELOW CEILING, _25 OPTIONAL COFFEE AND TEA MAKERS: VERIFY WITH OWNER IF REQUIRED. PROVIDE 1/2" FILTER WATER TO EACH IF REQUIRED. 26 WATER HEATER (WH -1). PIPE CONDENSATE LINE, T&P DISCHARGE AND DRAIN PAN TO FLOOR SINK. SEE WATER HEATER DETAIL 2/P6.0. KEY NOTES INCORPORATED engineering. architecture. planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: X305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: V\850279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y07 PLOT DATE: 2006 EQUIP # EQUIPMENT ITEM TYPE ELEVATION REMARKS EQUIP # EQUIPMENT ITEM TYPE ELEVATION REMARKS F 1 FLOOR SINK S 4 PREP SINK FAUCET CW/HW +38" A.F.F FS 2 FLOOR SINK EPDXY COATED CAST IRON FD 1 FLOOR DRAIN HD 1 � HUB DRAIN B 215 WATER HEATER CW/HW WFI 1 WATER HEATER CVJ S 512 ICE MAKER S/S FV! - VIA SYRUP BUNDLE WH 1 WATER HEATER G +15" A.F.F. S 512 ICE MAKER D/T FW - VIA SYRUP BUNDLE WATER CLOSET CW +29" A.F.F BOTH HANDICAP AND REGULAR C 001 PRESSURE FRYER - 8 HEAD G +12" A.F.F. UR I URINAL FLUSH VALVE CU`/ +47" A. F, F. WALL MOUNTED C 023 SINGLE OPEN FRYER G +12" A.F.F. UR 1 URINAL WASTE STUB W + 16-1/2" A.F.F. WALL MOUNTED C 024 DUAL OPEN FRYER G +12" A, F. F. L 1 LAVATORY TW +20" A.F.F. C 025 PRESSURE FRYER - 6 HEAD G +12" A, F. F. L 'I LAVATORY WASTE LINE W +16-1/2" A, F. F. S-592 WATER FILTER SYSTEM CW +94" A.F.F. INLET TO & OUTLET FROM FILTER - S 1) HAND SINK TW +18" A.F.F RIM OF LAV Co) +2'-8" A.F.F. <E72j> HOT WATER DISPENSER FW +48" A, F. F. SITS ON COUNTERTOP =,32 MOP SINK W -6" A.F.F. RECESSED IN FLOOR P-721 HOT WATER DISPENSER FW +48" A.F.F. SITS ON COUNTER TOP =S2 MOP SINK FAUCET CW/HW +36" A.F,F S 3 3 -COMPARTMENT SINK 3 -COMPARTMENT SINK FAUCET W CW/HW +19" A.F.F +38° A.F.F - 3 ,, 4 PREP SINK W +19 A.F.F - PLUMBING ROUGH -IN SCHEDULE O HOT WATER 1. ALL DIMENSIONS TO FLOOR SINKS, FLOOR DRAINS AND HUB DRAINS ARE TO CENTER OF FIXTURE. ® COLD WATER 2. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THIS DATA ON THE LOCATION OF ALL PLUMBING ROUGH -INS WITH INFORMATION PROVIDED ON THE ARCH * TEMPERED WATER AND STRUCTURAL DWGS AND THE EQUIPMENT ACTUALLY SUPPLIED AND TO CONFIRM THE CORRECTNESS OF ANY DIMENSIONS INDICATED HEREIN. 13 GAS @ FLOOR DRAIN FNIFLOOR SINK O HUB DRAIN ♦ WASTE OUTLET (D FLOOR CLEANOUT Q WALL CLEANOUT O FILTERED WATER O VENT UP FROM UNDER SLAB o WATER LINE THRU FLOOR, SYMBOL LEGEND mi GROUP INCORPORATED engineering. architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 1113#0004432 SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 0 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: 1\J750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y®7 PLOT DATE: 2008 1/2" CW- ' 1/2" TW S 4 3 1-1/4" DOMESTIC WATER SERVICE. FOR CONTINUATION, SEE CIVIL DRAWINGS. 1/2" CW -1/2" HW WATER ISOMETRIC N.T.S. 1 4 4" VTRJIL �- 4" V 1-1/2"V� I I 4" V S 1 FS 1 2" SSS 1-1/2"V CQ 1 12 FD 1 (2 FU) CO 1 I6" GW (5 FU) FCO 1 FD 1 3" GW l (2 FU) U01 1 4 SS 2 -WAY) FD 1 1 (17 FU) 3" GW �` 3" GW (2 FU) \ (2 FU)FD 1 ( S 3 GW 2" V �� HD 1 ECO 1 (2 FU) �� \ ' (9 FU) \ ��-3" GW / (2 -WAY) 6" GW (2 FU� (17 FU) FU (4 FUFD 1 3 (11 FU) `I 3" GW 2 SS ) 2" V FD 1 ` (2 FU) (/ /v l� (1 FU) I 3" SS ",2 FU ) 4 VTR) J� WC 1 (8 FU) �� /2 2" V 1 CONDENSATE 2 1/2" V 6GW DRAIN DOWN TO MOP 3" SS i 1 \ i � � ' II (30 FU) SINK (4 FU) 2 1/2"i (17G U) (18 FU \ \ 4 V� J 1-1/2"V I i 611 GW � S 2 WC 1 iT (2 FU) CO 1 �, ,�� (6 FU) 1-1 /2"V 2" V 2" V 2 -1/2" V 1'��yr �I) � Y 1 T FD '1 I i ,� I 2" V 3„ GW 6 GW � FD 1 I 4" SS / " �{ �-(2 FU) 0 FU) i 2.. V (4 U) (9 FU) / 3" GW 2 V FS 1 6" GW J QFC I S 1 L 1 I 3" SS r-�' (4 FU) 3" GW (6 FU) 2" SS 3" SS (5 FU) I 2" V (4 FU) CO 1 �COn1 (2 FU) I � 3�� GW F S _1 4 V 6., GW 2"SS�FS 1(2 FU) 12 (6 FU) I 3 GW (1 FU) S 2 (2 FU) FD 1 HD 1 3" GW (2 FU) CO 1 'c2 * S-512 * S-512 Fr P-001 3-532 * \ S-532 * 1/2" F2 1/2" 1/2" I 8 CO /NO JOINTS UNDER P-721 > FLOOR P-721 BUNN HOT WATER d--) DISPENSERS 3/4" COLD WATER C1� ENTIRE RUN OF DRAIN LINES ON INLET TO GREASE TRAP SHALL BE SCHEDULE 40 PVC OR NO HUB CAST IRON AS REQUIRED BY CODE. 1/2" TEMPERED WATER DOWN IN WALL TO HAND SINK/ LAVATORY. 1/2" HOT AND COLD WATER LINES DOWN IN WALL TO PREP SINK, THERMOSTATIC MIXING VALVE, REDUCED PRESSURE BACKFLOW PREVENTER PER LOCAL UTILITY REQS. PROVIDE SHUT-OFF VALVES AT BOTH SIDES OF BACKFLOW PREVENTER. VERIFY LOCATIONS WITH CIVIL DWGS, EMERGENCY GAS SHUT-OFF VALVE SHALL BE A MECHANICALLY OPERATED VALVE ACTIVATED BY THE EXHAUST HOOD FIRE SUPPRESSION SYSTEM IN ACCORDANCE WITH IBC AND NFPA. FACTORY GAS PIPING AT ROOF TOP UNIT FOR THROUGH THE BASE PIPE CONNECTION. SHUT-OFF VALVE SHALL BE LOCATED OUTSIDE OF THE UNIT, Q 1/2" FILTERED WATER UP THROUGH FLOOR CAP PIPE 1"A.F.F. FOR CONNECTION TO HEATED DISPLAY UNIT. Q 1/2" FILTERED WATER TO HOT WATER DISPENSERS P-721. STUB OUT 1/4" LINE W/ BALL VALVES, REFER TO INTERIOR ELEVATIONS. 10 GAS SHUT-OFF VALVE IN CEILING SPACE BY G.C. 6" SANITARY TO SEWER. FOR CONTINUATION SEE CIVIL DRAWINGS.— `-6" SS (47 FU) NEW SEWER SAMPLING BOX 6" SS (30 FU) WASTE AND VENT IS®MPTRII[' N T FILTERED EQUIPMENT AND LINES: S-592 - WATER FILTER FILTERED LINE (COLD WATER) S-512 - ICE MAKER - ABOVE SELF -SERVE BEVERAGE DISPENSER * S-512 - ICE MAKER - ABOVE DRIVE-THRU BEVERAGE DISPENSER S-532 - DRIVE-THRU BEVERAGE DISPENSER S-532 - SELF -SERVE BEVERAGE DISPENSER * FILTERED LINE (COLD WATER/HARD PIPING) P-001 - HEATED DISPLAY UNIT P-721 - BUNN HOT WATER DISPENSER P-721 - BUNN HOT WATER DISPENSER * FILTERED WATER SUPPLIED VIA SYRUP BUNDLE, SEE SCOPE OF WORK FOR RESPONSIBILITIES. FILTERED WATER IS®MIETRIc N T. 11 PIPE T&P RELIEF VALVE TO OUTSIDE OF BUILDING OR TO HUB DRAIN. RUN FULL SIZE PIPE FROM VALVE WITH TYPE "K" COPPER TUBING. 12 PROVIDE TRAP PRIMERS AS REQUIRED PER CODE. r = r INCORPORATED engineering • architecture *planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE; 305 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 Q 6-18-08 CITY -UTILITY DEPT. 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297900 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -yo 7 PLOT DATE: 2008 1/2" TEMPERED WATER TO LAVATORIES OIJI IT nL:L:VAL.VE (TYP) METER REMOTE — ROOFTOP CONDENSER DRINK COUNTER \LVE (TYP) JCW DOME'SIIC HVJ TEMPERING VALVE N.T.S. CONNECTION TO DRAIN PAN FULL SIZE VENT TO ATMOSPHERE EQUIPMENT CURB RETURN CONDENSATE DRAIN LINE THROUGH CURB, CONNECTTO MAIN ABOVE CEILING AND TERMINATE 2" ABOVE RIM OF MOP SINK. INSULATE ALL PIPING BEYOND THIS PENETRATION ` REMOVABLE THREADED CAP FOR CLEAN-OUT & WINTER DRAINING SEE WASTE PLAN FOR CONDENSATE LINE BELOW ROOF RTU CONDENSATE N.T.S. QTY MODEL a# DESCRIPTION 1 EF100T199E3N BWC HIGH EFFICIENCY COMMERCIAL WATER HEATER 1 MFK7 MANIFOLD KIT 1 DET12 EXPANSION TANK 1 HAL ALARM LIGHT W/ INSTALLATION INSTRUCTIONS 1 PK100 STAND * THE FOLLOWING IS INCLUDED IN THE MANIFOLD KIT: QTY DESCRIPTION 1 3/4" BLK GAS COCK 1 3/4" BLK UNION 1 3/4" BLK TEE 1 3/4" BLK CAP 3 3/4" x 2,,1/2" BLK NIPPLE 1 3/4" x 4 BLK NIPPLE 1 3/411 THD BALL VALVE 2 '1 1/2" FX UNION 6 1 1/2" CXC 90 1 1 1/2" CXC TEE 2 1 1/2" BALL VALVES CXC 1 1 '1/211 CHECK VALVES CXC 1 1 1/211 GALV_ ST 90 1 '1 '1/2" CX ST 90 1 H PT -507 1/21' P -TRAP 1 1/2" P4 SMA 1 1 1/2" x d 1/2" x 1/2" TEE COPPER 1 DIAL THERMOMETER 1 1/2" COPPER FEMALE FITTING ADAPTER 1 3" PVC 9W 1 1/211 PVC STREET 90` 1 1/211 PVC 900 ELBOW REMOTE1/4" CO2 LINE TO PNEUMATIC SYRUP LINES, WATER LINES FOR THE ROOFTOP \� ,� GATE REGULATOR (LOCATED CARBONATOR PUMPS, ICEMAKER WATER �. CONDENSER BEHIND DISPENSER FRONT LINES, CO2 LINE FOR PNEUMATIC GATE AND PANEL). PRESSURE PRESET TO PLAIN WATER FOR THE DISPENSERS ARE RIJN 30-35 MAX PSI, INSIDE THE TUBING BUNDLE. c� c0 ' _—_ 1 ROOF ~� -- REFRIGIERANT ` REFRIGERANT i I I�� - — - I I CEILING LINES LINES 1/211-D. _ 3/F3LINETTO ER LINE IC:EMAK- WATER INLET WATER INLET - IN REAR IN REAR I I I I I I � 1/2 x 3/8 x 3/8 "Y" POWER POWER I III I I I PorAHLEWATER - - — 1/2 NPT X 1/2 BARB CONNECTION IN CONNECTION IN I i I IIII 3/8LIN ESTO I I I I SOURCE WATER FILTER PEAR REAR I ,III uISPENSERs��I ICI I I II I I I HAT"R iO FRA'AnY :I':'"Ni-�7 t:AF.ON\TOR � — E ICE II I LL0lCAFaKATEPTOPRWATlY0WE\6Efl— —� 1/2' LINE LN(:T+;-ki A0'FIER TTECO\CA eCI5FE=4SC� iGR_ MAKER MAKER I • I DRAIN IN REAR DRAIN IN REAR I III IIISHUT OFF VALVE III L - - - - - - I ON BANRB IT ZINGS CORNELIUS/ - - I I IIII I_ - OUTLET REMCOR I I IIII L ED250 I I IIII ----- _ w �� --Wy� I I IIII S_ N AH To To i*nn4 A'13' �+V �L'1 v0•1 OBJ F':.�i ICEMAKER ICEMAKER IIIIIII � O i 31-ILl<c021TANK 3 RECEPT. I ('III o js RECEP r. i 1 1 A 115/60/'12 0 I I I I I I �._i.,-,Y, ._F 11T7-V,r,E:,F, '115/60/1 20 I I I AMPS EACH I( IIII D O PRE SET i I AMPS EA. - I� PRE-SET Cod I I I I CO2 I I I I REGULATOR I III F„ REGULATOR I - - I L - - 75PSI I I IIII O Cl ICEMAKER DRAINDISPE DRAINNSER i I I I I I II IIII A I I I I A R II IIII CARBONATOR I II CARBONATOR I II IIII SM rU -AVER - - LL IF ICEMAKER DRAIN_::�/ TYPICAL SYRUP LINE ONLY '1 FLOOR MNK DISPENSER DRAIN FLOOR MNK SHOWN FOR CLARITY) — —CO2 LINE DINING ROOM DRIVE THRU BACK ROOM - - - - - - - WATER LINE SYRUP LINE co 0 r WATER HEATER SCHEDULE N.T.S. I S GENERAL NOTES: 1. OVERALL FILTER DIMENSIONS: 25-1/211 WIDE x 9" DEEP x 32" HIGH 2. SEE 2/ V2,0 AND THE SCOPE OF WORK FOR SCOPE DEFINITIONS. 3. ROUGH -INS SHALL BE PROVIDED BY THE CONTRACTOR. 4. INSTALLATION MUST COMPLY WITH ANY STATE OR LOCAL PLUMBING CODES, 5, THE FILTER MUST BE PROTECTED AGAINST FREEZING. 6, USE ONLY TEFLON (HIGH -LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE. 7. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F. 8. SEE THE EQUIPMENT PLAN FOR LOCATION. SEE 12/ P6,0 FOR BUNDLE DETAILS 9. "Y" FOR ICE MACHINES SUPPLY LINES 10, SHALL BE INSTALLED @ FILTER OUTLET. BACKFLOW PREVENTERS FOR FILTER ' 11. ASSEMBLY ARE PROVIDED, NOTE INSTALL ELECTRICAL, WATER, AND DRAIN IN ACCORDANCE WITH ALL LOCAL, STATE & FEDERAL CODES. EQUIPMENT RATING: ED250 DISPENSER - '1 15V, 3.5 AMPS CARBONATOR -11 60 Hz, 7.0 AMPS DRINK SYSTEM SCHEMATIC N.T,S, CALE OUT CO2 TO ICE SPARE MACH. SCALE -OU /ATER LINE TO ICE SPARE TO CARD. MACH. /ATER LIN ro NON-CARB WATER LINE ATER LIN TO CARD. TO NON-CARB SYRIJP SYRUP SYRUP SYRUP Z 7 -'(S -UP YRUP SYRUP NON -INSULATED SYRUP BUNDLE INCLIJDES 17 LINES SYRUP BUNDLE CONFIGURATION N,T.s, 112 - SUPPLY MAIN FROM METER 10 BOOSTER BUILDING TYPE: K -y07 PLAN VERSION: TANK SITE NUMBER: BOOSTER STORE NUMBER: SELECT DRINK/ DRAWING DATE: PUMP ICE FILTRATION s592 ----------- --------------- 1 F2 VALVE MANIFOLD I DRIVE-THRU I 5511 ICE MACHINE tLu - - SELF -SERVE 1 m S511 ILo T ICE MACHINE O T ~ J Z O_ n v' Co mf � MJ <� U DRIVE-THRU DRINK <3m> ' SYSTEM FI SELF -SERVE DRINK < 5533 SYSTEM CARBONATOR 1 5570 CARBONATOR 2 S5"10 SEE 11/P6.0 FOR PLUMBING CONNECTIONS OF ADDITIONAL EQUIPMENT TO FILTER SYSTEM, ------------------------- L-------------------------- 1' 0 UTILITY - TOILET ROOMS/ GENERAL KITCHEN (COLD) I POWER SOAK (%v 3 COMP, SINK N014 I I WATER HEATER B215 UTILITY - GENERAL KITCHEN II (HOT) I L--------------------------— LEGEND -------------------------—LEGEND Nxxx KITCHEN EQUIPMENT # --�— FLOW ARROW (SHEET A2,0) _ _ % POINT OF CONNECTION (PEPSI) F_ SYSTEM �- - - -1 POINT OF CONNECTION (GC) WATER FILTRATION SCHEMATIC N.T.S. I FACE OF SINK NOTE: 1/2" PIPING SHALL BE HARD COPPER LINE, OR BRAIDED STAINLESS HOSE. SOFT COPPER IS NOT ACCEPTABLE. WALL 1/2" SWEAT/ 3/8" COMPRESSION 1/211 COPPER LINE FROM MIXING VALVE ABOVE 1/2" SWEAT W/ 1/2" MALE ADAPTER 1/2" ANGLE STOP VALVE 1/211 HARD COPPER LINE TO SINK 1/2" WALL STRAP 1/2" SWEAT ELBOW SINGLE FOOT PEDAL .1/4" X 3" TAPCON HEX HEAD SCREW 1/2" SWEAT W/ '1/2" MALE ADAPTER FOOT PEDAL N.T.S, WALL LAVATORY FLOOR MOUNT UPRIGHT SUPPORT 4x4 WELDED BASE PLATE W/ (4) 1/2" HILTI KWIK BOLT II OR EQUAL FINISH FLOOR LAVATORY SUPPOR- ED Lu L_ �T7 Nz>O v) SERVICE CLEARANCES TOP 1811 SIDES 4" FRONT 24" 1-1/2" —_-D 1 FLUE THRU ROOF - SEE DETAIL 20/A6.0 WATER HEATER PLATFORM PROVIDED BY W.H. MANUFACTURER. FINISHED FLOOR (�D THERMAL EXPANSION TANK BY WATTS - SEE PLUMBING SCHEDULE - STRAP AND SUPPORT TO WALL 5 SCHEDULE 40 PVC, MINIMIZE TURNS AND TRANSITIONS, GAS COCK VALVE WITH FULL SIZE DIRT LEG Q 3/4" DRAIN WITH VALVE & CAP Q COMBINATION TEMPERATURE AND PRESSURE RELIEF PER LOCAL CODE Q RUN T&P DISCHARGE FULL SIZE TO HUB DRAIN 10 22" DEEP HEAT TRAP 11 AIR INTAKE W/ INTERNAL INSECT SCREEN PROVIDED BY MFR. 12 SUPPORT VENT PIPE RUNS EVERY 5'-0" VERTICALLY AND EVERY 3'-0" HORIZONTALLY, 13 OUTLET THERMOMETER PROVIDED BY MFR, LOCATE WITHIN 12" OF W.H. OUTLET, 14 SEE DETAIL 9/P6.0 FOR SCHEDULE OF ITEMS PROVIDED BY W.H. MFR. 15 DRAIN PAN TO HUB DRAIN. l 6D P -TRAP AND LINE TO DRAIN PROVIDED BY MANUFACTURER, LEAVE AIR GAP WATER HEATER N-T,S, ALL WORK THIS DETAIL PER DETAILS 6, 11 &'12/P6.0 FILTER LINE F1 SUPPLIES FILTER LINE F2 SUPPLIES FILTER LINE F2 SUPPLIES BUNDLED TUBE BY PEPSI BUNDLED TUBE BY PEPSI 1. DRIVE THRU DRINK STATION 1. KFC HEATED DISPLAY 1. ICE MACHINES 2, SELF SERVE DRINK STATION 2.) WELLS HOT WATER MACHINE T135/620-5 WITH SCALE -OUT HIGH FLOW WATER FILTRATION SYSTEM KEY NOTES: Q 3/4" COLD WATER INLET TO 1/2" COPPER LINE AND FITTINGS AT FILTER. Q 3/4" OUTLET W/ INTEGRAL BACKFLOW PREVENTER, EQUAL TO WATTS REGULATOR CO. SERIES 007 AND SERVICE BALL VALVE, GENERAL NOTES: 1. OVERALL DIMENSIONS 25-1/211 WIDE x 9" DEEP x 32" HIGH 2, SEE SCOPE OF WORK FOR ADDITIONAL INFORMATION. 3, INSTALLATION MUST COMPLY WITH STATE OR LOCAL PLUMBING CODES. 4. THE UNIT MUST BE PROTECTED AGAINST FREEZING. 5. USE ONLY TEFLON (HIGH -LOW TEMPERATURE) TAPE TO SEAL THREADED PARTS; NO PIPE DOPE, 6. DO NOT INSTALL WHERE LINE PRESSURE EXCEEDS 125 PSI OR WHERE TEMPERATURE EXCEEDS 100 F, 7. SEE SHT. A2.0 FOR LOCATION, WATER FILTER SYSTEM N.T,S. 1 4 GROUP INCORPORATED engineering. architecture . planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-06'19 SEAL EDUARDO L CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -y0 7 - 0!1111 t, DETAILS PLOT DATE: 2008 AMERICANA BOULEVARD Luminaire Schedule 10-28-2007 Symbol Qty Label Arrangement Lumens LLF Description Total Watts 3 A ROTATED 2 IN 90 110000 0.720 GBR—FP-1000—MHR—CT—D180 2RTD ON 24' POLE 2160 1 B ROTATED 2 IN 90 110000 0.720 GBR-2-1000—MHR—CT D180-2RTD ON 24' POLE 2160 O 3/4" C. - 2 #10, #10 GRD. (TYP. FOR ENTIRE CIRCUIT.) DIRECTIONAL' IGN. O MENU BOARD. PYLON SIGN. UNDERGROUND ELECTRIC SERVICE TO UTILITY CO. TRANSFORMER. REFER TO CIVIL SHEETS FOR LOCATION AND ROUTING. VERIFY AND COORDINATE ALL REQUIREMENTS WITH UTILITY CO. Q UNDERGROUND TELEPHONE SERVICE. REFER TO CIVIL SHEETS FOR LOCATION AND ROUTING. VERIFY AND COORDINATE ALL REQUIREMENTS WITH UTILITY CO. Q PREVIEW BOARD. ORDER CONFIRMATION BOARD/ SPEAKER POST. INCORPORATED engineering • architecture planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 1::Q 4Fnnnn AQ') SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES • electrical engineer • CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -Y0 7 PLOT DATE: 2008 NATIONAL ACCOUNTS INSTALL STANDARD PACKAGE. SUPPLY & INSTALL NON STANDARD COMPONENTS YUM! BRANDS HAS DEVELOPED A NATIONAL ACCOUNT AGREEMENT WITH GE SUPPLY FOR THE SUPPLY AND DISTRIBUTION OF ELECTRICAL SWITCHGEAR EQUIPMENT FOR COMPANY DEVELOPMENT ONLY. FRANCHISEES SHOULD NOT OBTAIN SWITCHGEAR FROM GES BECAUSE THE UFPC AGREEMENTS DESIGNED TO PROTECT FRANCHISEES HAVE NOT BEEN COMPLETED. UNDER THIS AGREEMENT, THE CONTRACTOR IS RESPONSIBLE FOR PURCHASE AND INSTALLATION OF THE SYSTEMS DESCRIBED IN THE PLANS. ALL COMPANY PROJECTS MUST CALL GENERAL ELECTRIC SUPPLY'S NATIONAL ACCOUNT DEPARTMENT FOR A PRICE QUOTE AND A BILL OF MATERIAL CONFIRMATION FOR THEIR SPECIFIC PROJECT. SEE THE SWITCHGEAR SECTION IN THE SCOPE OF WORK FOR ADDITIONAL INFORMATION. PRIMARY CONTACT: MIKE URKOWSKI PHONE: (630) 718-6529 FAX: (630) 718-6567 EMAIL: MIKE.URKOSKICOGE.COM THE GE SUPPLY GEAR PACKAGE CONSISTS OF SERVICE ENTRANCE, SWITCHGEAR, MAIN PANELS, SUB PANELS, AND LIGHTING CONTACTORS. GENERAL ELECTRIC IS ALSO ABLE TO SUPPLY A FULL LINE OF GE AND NON -GE ELECTRICAL PRODUCTS TO COMPLIMENT THE GEAR PACKAGE. BE PREPARED AT TIME OF ORDER OR QUOTE REQUEST TO PROVIDE ALL PROJECT DETAILS REGARDING SPECIFICATIONS AND QUANTITIES AS SITE SPECIFIC DESIGN MAY NOT MATCH PROTOYPICAL DESIGN. WI—I.r.T.r.. UNDERGROUND FEEDERS 120/208V, 30,4W CU 22KAIC, CURRENT TRANSFORMER (CT) CAN AND METER SOCKET PER SERVING UTILITY CO. SPEC. V `T - INCOMING SERVICE LATERAL TO UTILITY TRANSFORMER TO PANELS "A", "B", "D", "H" & DUAL -LINE EQUIPMENT CABINET NOTE: CONFIRM DIMENSIONS WITH SUPPLIER SERVICE ENTRANCE EQUIPMENT ELEVATIOC 1. THERE SHALL BE U.L. LISTED SERIES RATING BETWEEN CKT. BREAKERS LOCATED ATTHE DISTRIBUTION PANEL AND THE DOWNSTREAM 10k A.I.C. RATED CIRCUIT BREAKERS AT PANELS "A", "B", "C", "D"& "H" BASED 2X4 FLUORESCENT FIXTURE NL NIGHT LIGHT FUSIBLE DISCONNECT SWITCH ON THE MAXIMUM FAULT CURRENT AS DETERMINED ATTHE SERVICE ENTRANCE. THE NFPA-70'SIX WITH STARTER SWITCH' MAXIMUM RULE SHALL APPLY ATTHE POINTAT WHICH THE SERVICE ENTERS THE BUILDING AS �S CEILING MOUNTED SPEAKER FUSED DISCONNECT SWITCH DEFINED BY NFPA-70 (CURRENT EDITION IN FORCE AT THIS SITE). NOTIFY ENGINEER WHERE LOCAL 2X4 FLUORESCENT FIXTURE CONDITIONS REQUIRE ALTERNATE LOCATIONS OR SINGLE POINT DISCONNECT. WITH BATTERY PACK WALL MOUNTED SPEAKER NON-FUSED DISCONNECT SWITCH 2. SEE SCOPE OF WORK FOR DETAILS REGARDING OWNER SUPPLIED AND/OR INSTALLED PRODUCTS. JUNCTION BOX GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL OTHER ASPECTS OF THE PROJECT Lr�J 1X4 FLUORESCENT FIXTURE WALL MOUNTED JUNCTION BOX PC PHOTOCELL 3. IF UTILITY COMPANY PROPOSES A SERVICE DIFFERENT FROM THAT ILLUSTRATED, CONTACT THE CONSTRUCTION ENGINEER FOR A DECISION BEFORE PROCEEDING. COORDINATE AVAILABLE SHORT ® TELEPHONE OUTLET R5 RAIN SENSOR CIRCUIT CURRENT W/ LOCAL UTILITY AND PROVIDE CIRCUIT BREAKERS W/ SUFFICIENT INTERRUPTING 1X4 FLUORESCENT FIXTURE CAPACITY. WITH BATTERY PACK DEDICATED GROUNDED OUTLET FLUORESCENT WALL MOUNT FIXTURE $ DUPLEX GROUNDED OUTLET 4. COORDINATE CT METERING COMPARTMENT SIZE WITH LOCAL UTILITY COMPANY, THE LOCAL ELECTRICAL DOWNLIGHT FIXTURE EMERGENCY LIGHT INSPECTOR AND THE NATIONAL ELECTRICAL CODE TO MEE(ALL REQUIREMENTS BEFORE PURCHASE Q DOUBLE DUPLEX GROUNDED OUTLET AND INSTALLATION. NEW METER BY LOCAL UTILITY COMPANY. SUSPENDED DOWNLIGHT FIXTURE 4� GROUND FAULT DUPLEX OUTLET < SINGLE POLE, SINGLE THROW TOGGLE SWITCH 5. ALL WIRING SHOWN SHALL BE COPPER TYPE "T HHN/THWN" EXCEPT FEEDERS FROM UTILITY PENDANT MOUNTED LIGHT FIXTURE ' GROUND FAULT DUPLEX W/ BOTT. HALF SWITCHED LOW VOLTAGE TRANSFORMER TRANSFORMER TO SWITCH BOARD MAY BE ALUMINUM. GROUND FAULT DEDICATED OUTLET TRACK MOUNTED SINGLE POLE, SINGLE THROW TOGGLE PENDANT LIGHT FIXTUREAAA ® CEILING DUPLEX OUTLET �P SWITCH W/ PILOT LIGHT DIRECTIONAL FIXTURE DUPLEX ISOLATED GROUND OUTLET IRI RELAY FIXTURE, TRACK MOUNTED DOUBLE DUPLEX ISOLATED GROUND OUTLET CONDUIT RUN, UNDERGROUND DIRECTIONAL FIXTURE, -®- DEDICATED ISOLATED GROUND AAATRACK MOUNTED TO 0 SMOKE DETECTOR UNDERSIDE OF INTERIOR CANOPY �D- SPECIAL PURPOSE OUTLET COOLER FIXTURE 0 CEILING SPECIAL PURPOSE OUTLET EXTERIOR WALL FIXTURE it ELECTRICAL PANEL. SEE SHEEP E2.1 FOR PANEL SCf-IED. EXIT SIGN (WALL MOUNTED) 4 HOLD UP EMERGENCY BUTTON EI EXTERIOR DECORATIVE WALL FIXTURE EXIT SIGN (CEILING MOUNTED) 'O' ELECTRICAL MOTOR EXTERIOR DECORATIVE WALL FIXTURE FS -D-1 DUCT MOUNTED SMOKE DETECTOR on SECURITY STROBE CONNECTIONTO EQUIPMENT WPG WEATHERPROOF GROUND FAULT ELECTRICAL LEGEND GENERAL NOTES I D (�1_) WIRE ISOLATED GROUND TO ISOLATION GROUND BUS IN PANEL AND LAND ISOLATED GROUND TO SINGLE POINT GROUND. "DO NOT COMBINE COMMON GND TO ISOLATED GROUND". Q 6 BUILDING MAIN DISCONNECT FOR THIS SERVICE: (MAXIMUM 6 MAINS PER N.E.C) LABEL EACH MAIN BREAKER AS INDICATED: "MAIN 1 OF 6" (ENGRAVED LETTERS x 3/4" HIGH) "MAIN 2 OF 6" "MAIN 3 OF 6" "MAIN 4 OF 6" "MAIN 5 OF 6" "MAIN 6 OF 6" CIRCUIT BREAKER #5 IN THE SWITCHBOARD SHALL BE 100A PANEL "H" SHUNTTRIP BREAKER CONTROLLED BY HOOD'S FIRE EXTINGUISHER SYSTEM, IF QMB BOARD IS USED, PROVIDE MAIN SHUNT TRIP BREAKER (SAME SIZE) IN PANEL "H". Q PROVIDE 2" CONDUIT STUBBED INTO BUILDING FROM LATERAL POLE FOR TELEPHONE. O VERIFY AVAILABLE FAULT CURRENT AT SERVICE ENTRANCE WITH THE UTILITY CO. AND PROVIDE "AIC" RATING AS REQUIRED. 6 (3) 5/8" DIA. x 10'-0" COPPER CLAD GROUND RODS. INSTALL 10'-0" APART AND CONNECT GROUND SYSTEM PER N.E.0 ARTICLE 250. Q INSTALL UNDERGROUND SERVICE LATERAL TO UTILITY TRANSFORMER PER SERVING UTILITY COMPANY SPECIFICATIONS. (3) 3"0 - 4#300 KCMIL IN EACH TO PAD MOUNT TRANSFORMER. GC/ ELECT. CONTRACTOR SHALL COORDINATE SERVICE POLES PER LOCAL UTILITY CODE, IF ALUMINUM CONDUCTORS ARE USED PROVIDE (3) 3"C - 4#400 KCMIL IN EACH. PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 3-1914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES • electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 333 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: 305) 444-9696 SEAL 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLOF31DA PLOT DATE: 2008 GENERAL NOTE: LIGHTING CIFICUI-TS INSIDE THE BUILDING SHALL BE WIRED THRU LIGhTTING CONTACTORS. REFER TO DETAILS ON SHEET" E6.0. KEY NOTES: PROVIDE LOCK -ON BREAKER. Q CIRCUITS TO BE WIRED THRU EXTERIOR LIGHTING CONTROL RELAY. SEE DETAIL 8/E6.0. FOR PARKING LOT LIGHTS AND OUTSIDE SIGNS: PROVIDE (5) 3/4"C FROM PANEL "B" AND STUB OUl" 10'-0" AWAY FROM THE BUILDING. VERIFY EXACT LOCATION OF STUB PRIOR TO ROUGH -IN. LOADS MAY VARY WITH LOCATION -- VERIFY. VERIFY OUTDOOR VOLTAGE DROP FOR ALL PARKING LIGHTING CIRCUITS. (D DRIVE-THRU TIMING SYSTEM: 8-200,8-250,8-251 CfjD CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAY -FRONT. SEE DETAIL 18/E6.0. CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAY -REAR. SEE DETAIL 14/E6.0. PANEL'D' WILL BE SUPPLIED WITH 400A MAIN LUGS WHEN PROVIDED BY SQUARE -D (AS SHOWN, FOR FRANCHISEE DEVELOPMENT ONLY). WHEN G.E. PANELS ARE USED "CHE MAIN LUGS WILL BE RATED @ 600A. (EAST REGION, COMPANY DEVELOPMENT ONLY) PANEL TI' WILL BE SUPPLIED WITH 100A MAIN LUGS WHEN PROVIDED BY SQUARE -D (AS SHOWN, FOR FRANCHISEE DEVELOPMENT ONLY). WHEN G.E. PANELS ARE USED THE MAIN LUGS WILL BE RATED Cu) 125A (COMPANY DEVELOPMENT ONLY). GENERAL NOTES & KEY NOTES PANEL LIGHTING (W) KITCHEN EQUIP. (W) *** HVAC (W) MISCELLANEOUS (W) CONNECTED LOAD DEMAND LOAD (W) A - 22341 - 14420 46991 36761 B 43358 - - 500 44358 55232 D - 18434 70866 20825 110125 '110125 H 600 20162 - - 31618 20912 I TOTAL 1 44458 1 60937 1 70866 1 35745 1 233092 1 223121 1 223121 W C 120/208V, 30-4W = 648 A LARGEST MOTOR LOAD = 1659W LOAD KEY LEGEND LOAD DESCRIPTION APPLICABLE FACTOR L LIGHTING 125% K KITCHEN EQUIPMENT 65% *** H HVAC 100% M MISC. EQUIPMENT 100% A&E NO. # WIRES & SIZE GRND WIRE SIZE ***KITCHEN EQUIPMENT DEMAND FACTORS PER 2002 NEC SECTION 220-20 ALLOWS FOR PERCENTAGES WITHIN EACH PANEL ACCORDING TO THE FOLLOWING EQUIPMENT QUANTITIES: 1 -100%; 2 -100%; 3 - 90%; 4 - 80%; 5 - 70%; 6 AND OVER - 65%. THESE PERCENTAGES DO NOT CARRY OVER INTO THE LOAD SUMMARY, WHICH IS CALCULATED AT 65%REGARDLESS. LOAD SUMMARY CIRCUIT NO. GRND WIRE SIZE # WIRES & SIZE A&E NO. LOAD DESCRIPTION o O -i WATTS TRIPw AMPS Lu a- Lu _ a w a- TRIP AMPS WATTS 0 O LOAD DESCRIPTION A&E NO. # WIRES & SIZE GRND WIRE SIZE CIRCUIT NO. A B — C A B C B-1 #12 2 #12 - KITCHEN LIGHTS ) L 1320 �` �'� 20 1 A 1 20 794 ,� �� .� L DINING ROOM LIGHTS 5 - 2 #12 #12 B-2 B-3 #12 2 #12 - KITCHEN, OFFICE, RR LIGHTS, EF -4 & 5 6 L 744 20 1 B 1 20<` 1200 >< L DINING ROOM 'TRACK LTG 5 - 2 #12 #12 B-4 B-5 #12 2 #12 - COOLER/FREEZER LIGHTS ® L >< 800 20 1 C 1 20 :.--/ , ., 1350 L DINING ROOM TRACK LTG � - 2 #12 #12 B-6 B-7 #12 2 412 - LIGHTING CONTROL Q� M 500 j<,.� �j.,�, 20 1 A 1 20 1200 /'' w j� L PUB SIGN 5 - 2 #12 #12 B-8 B-9 #10 2 #10 - OUTSIDE LIGHTS Q L< 1584 ��- 20 1 B 1 20 200 L LED LIGHTING 2 - 2 #12 #-12 B-10 B-11 #10 2 #10 - OUTSIDE LIGHTS Q L %`�~ >"�-. 1750 20 1 C 1 20l _� 1200 L POP PANEL 2 2#12 #12 B-12 B-13 #10 2 #10 - OUTSIDE LIGHTS 2 L 876 �>'` 77 20 1 A 1 20 1200 �;:� L KFC SUNDAY DINNER SIGN 5 - 2 #12 #12 B-14 B-15 #12 2#12 - MENU BOARD @ D/T Q L >< 500 %' 20 1 B 30 �i�__ 2160 L PARKING LIGHTING �� - 2 #10 #10 B-16 B-17 #12 2 #12 - SPARE ``' _:, _-''� ,_ 0 20 1 C 2 > j .� 2160 L - - - - B-18 B-19 #12 2 #12 WINDOW SIGN L 1200 ` �.�, 20 1 A 20 1080 >�"� .� -- L PARKING LIGHTING 0`_".� - 2 #10 #10 B-20 B-21 #12 2 #12 - WINDOW SIGN L< 1200 20 1 B 2 1080 f: L - - - B-22 B-23 #12 2 #12 - WINDOW SIGN L >< 1200 20 1 C 20 /"`- —, 1080 L PARKING LIGHTING 2 3 2 #10 #10 B-24 B-25 - - - SPARE L - �? .�-'"" 20 1 A 2 1080 L - - - B-26 B-27 #12 2 #12 - KFC WALL SIGN L 1200 ><20 1 B 1 20 >< 1200 ., L PUB SIGN - 2#12 #12 B-28 B-29 #12 2 #12 - KFC WALL SIGN Q L >< > < ' 1200 20 1 C 1 20 :5::77>< 1200 L PUB SIGN 5 2#12 #12 B-30 B-31 #12 2 #12 - KFC WALL SIGN L 1200 20 1 A 1 20 1500%<� � ' L DINING ROOM TRACK LTG - 2#12 #12 B-32 B-33 #12 2 #12 - TRANSOM LIGHTS 2 L >< 1200 � n 20 1 B 1 20 !j! 0 j<.�l - SPARE - - - B-34 B-35 #12 2 #12 - TRANSOM LIGHTS ��/ L , �! �,< 1200 20 1 C 1 20 /' >< 1200 L KFC CANOPY SIGN Q - 2#12 #12 B-36 B-37 #12 2 #12 - TRANSOM LIGHTS 2 Q L 1000 .� �,j-''� _ j< 20 1 A 1 20 1 ><200 < > L KFC "MUG" SIGNp - 2#12 #12 B-38 B-39 #10 2# 10 - PYLON SIGN Q L > .` 1200 ><r 20 1 B 1 20 >< 1200 >< L KFC "POP" PANEL - 2#12 #12 B-40 B-41 #10 2 #10 �-DnEcTiONAL SIGNS L /"< :><,_ 1200 20 1 C -1 20 �` ��-y 0 - SPARE - - - B-42 6096 7628 7350 8054 7040 8190 WA FTS: BUS A 14150 LIGHTING = 43858 x 1.25 = 54823 W BUS B '14668 OTHER LOADS (MISC.) = 500 W BUS C 15540 TOTAL LOAD= 55323 W TOTAL 44358 TOTAL CURRENT= -154 A PANEL B ELECTRICAL DATA 120/208V PANEL TYPE NQOD MOUNTING FLUSH MAINS 225A M.L.O. PHASE 30,4W NEUTRAL BUS AMPACITY 225A GROUND BUS AMPACITY 225A A.I.C. RATING 10 KA LIGHTING PANEL INCORPORATED engineering s architecture e planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558,4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDOL.CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer • CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD, SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 4444550 FAX: (305) 444-9696 SEAL 0 CONTRACT DATE: 10 28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA AND LOAD SUMMARY E2.1 PLOT DATE: 2008 0 A. HORIZONTAL DIMENSIONS TO J -BOXES ARE FROM FACE OF STUD TO CENTER OF BOX, J. ELECTRICAL EQUIPMENT ENCLOSURES SHALL BE NEMA -1 FOR INTERIOR AND NEMA U.O.N. VERTICAL DIMENSIONS TO J -BOXES ARE FROM FIN. FLOOR TO CENTER OF BOX, 3R FOR EXTERIOR. IN COASTAL REGIONS THE STANDARD FOR OUTSIDE SHALL BE U.O.N. NEMA -4X. B. ALL CONDUIT DROPS ARE INSIDE WALLS U.O.N. SEE ARCH. DWGS FOR WALL DIMS C. ALL J -BOX CIRCUITS, CONDUITS, FIXTURES, ETC. SHALL BE AS INDICATED ON THE ELECT. DWGS AND SPECS. D. CONTRACTOR TO VERIFY UNDERGROUND CONDUIT LOCATIONS PRIOR TO POURING SLAB. E. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO COORDINATE THIS DATA ON THE LOCATION OF ELECT. ROUGH -INS WITH INFO PROVIDED ON THE ARCH. AND STRUCT. DWGS AND THE EQUIPMENT ACTUALLY SUPPLIED, AND TO CONFIRM THE CORRECTNESS OF ANY DIMENSIONS HEREIN. F. LOCATIONS OF ALL OUTLETS MAY BE RELOCATED TO NEAREST STUD. DO NOT CU!' INTO STUDS. G. FOR EXACT LOCATIONS OF KITCHEN & MECHANICAL EQUIPMENTAND POINTS OF CONNECTION, REFER TO KITCHEN & MECHANICAL EQUIPMENT DRAWINGS AND MANUFACTURER'S SHOP DRAWINGS. H. ALL CIRCUIT FEEDERS AND DISCONNECTS SHALL BE SIZED BY NEC. I. CONTRACTOR SHALL VERIFY CIRCUIT BREAKER, DISCONNECT SWITCH, STARTER AND FUSE SIZES WITH SELECTED EQUIPMENT MANUFACTURER'S SHOP DRAWINGS PRIOR TO PLACING ORDER AND PROVIDE EVERYTHING AS REQUIRED. K. PER SECTION 210.8(B)(3) NEC 2002, ALL '15 AND 20A, -120V RECEPTACLES IN COMMERCIAL KITCHENS ARE REQUIRED TO BE GFCI PROTECTED. THIS INCLUDES ISOLATED GROUND RECEPTACLES. L. DO NOT MEASURE/LOCATE OUTLETS ON DRAWINGS. USE DIMENSIONS PROVIDED M. CONDUIT MAY RUN UNDER SLAB AT G.C.'S DISCRETION. POWER PLAN ry GENERAL M os *1 11 111 miIi Q REFER TO ROOF PLAN. qui INSTALL SURFACE MOUNTED IN CONDUIT RUNNING ON KITCHEN SIDE OF CABINETRY REAR WALL. LOWER MAPS LINE EQUIPMENT TO BE POWERED FROM FLOOR MOUNTED RECEPTACLES AS INDICATED ON PLAN. COORDINATE WITH MANUFACTURER'S SHOP DRAWINGS FOR EXACT DEVICE LOCATIONS, PRIOR TO ANY ROUGH -IN WORK. ANSUL J -BOX - LOCATE ABOVE CEILING. LOCATED INSIDE SHELL OF HEATER. Q CONDENSING UNIT. SEE SCOPE OF WORK. TWIST -LOCK RECEPTACLE. SWITCHGEAR LOCATION. ALIGN OUTLETS ON CEILING ALONG CENTERLINE OF TABLE. 10 CONDUIT SHALL BE HARDWIRED INTO EQUIPMENT. RUN FROM A J -BOX IN THE WALL. 11 GENERAL CONTRACTOR SHALL FURNISH AND INSTALL VERTICAL METAL CHASE TO PRE-INSTALLED ELECTRICAL BOX, FOR POWER TO UPPER MAPS LINE EQUIPMENT. COORDINATE EXACT LOCATION WITH MAPS LINE EQUIPMENT, AND EXACT REQUIREMENTS WITH EQUIPMENT MANUFACTURER, PRIOR TO ANY ROUGH -IN INSTALLATION. 12 NOT USED. 13 CONDUIT DROP FROM ABOVE SIGN ELEMENT. THIS ITEM SHALL BE HARD -WIRED. INCORPORATED engineering • architecture • planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX. (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES • electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD, SUITE 329 CORAL GABLES , FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL 0 A 0 0 0 0 CONTRACT DATE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D 81 -FE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -Y07 PLOT DATE: 2008 THE DEDICATED POS POWER CIRCUIT REQUIRES AN ISOLATED GROUND IN ADDITION TO THE NORMAL COMMON BUILDING GROUND. THE ISOLATED GROUND WIRE SERVES TWO PURPOSES: * AS A SAFETY PATH TO GROUND. * AS A ZERO REFERENCE POINT FOR ALL POS DIGITAL LOGIC. THE GROUND MIDST EXHIBIT THE LOWEST POSSIBLE IMPEDANCE TO MINIMIZE VOLTAGE TRANSIENTS AND NOISE. BE SURE TO: * USE AN INSULATED CONDUCTOR FOR THE ISOLATED GROUND WIRE. * RUN THE ISOLATED GROUND WIRE THROUGH THE SAME CONDUIT AS THE HOT AND NEUTRAL WIRES. * INS -FALL ONLY ISOLA-TED GROUND (IG) TYPE RECEPTACLES. * CONNECTTHE ISOLATED GROUND WIRE TO BUILDING GROUND ONLY ATTHE MAIN SERVICE PANEL. * VERIFY "THAT IG RECEPTACLES PRE -WIRED IN OWNER SUPPLIED EQUIPMENT HAVE A TRUE ISOLATED GROUND THAT CAN BE TRACED BACK TO THE BUILDING GROUND AT THE MAIN SERVICE PANEL. DO NOT CONNECT THE ISOLATED GROUND WIRE TO THE CONDUIT, JUNCTION BOXES, THE FRAME ON A SUBPANEL, OR ANY OTHER METAL SURFACE. DEDICATED CIRCUITS: DEDICATED CIRCUITS REQUIRE A DEDICATED HOT AND A DEDICATED NEUTRAL THATARE NOT SHARED WITH ANY OTHER CIRCUITS. IG RECEPTACLES MUST BE "PHASE ALIGNED" WITH THE "B" PHASE OF BUILDING SUBPANEL "A". COMMON GROUND (EQUIPMENT GND) INSTALLED PER N.E.C. 1 — I ISOLATED GROUND (IG) (#12 WIRE) ISOLATED GROUND (IG) (#6 WIRE) saw -9m gmwp_� IG RECEPTACLE IG RECEPTACLE I DEDICATED HOT SUBPANEL MAIN SERVICE PANEL (OT? EQUIPMENT SERVICE CABINET) SEE SHEET E5.0 (HM 1 08 ISOLATED GROUND OUTLE"T FOR D/T SYSTEM SEE SHEET E5.0HM 03El LINE OF WORK SURFACE ISOLATED GROUND OUTLET FOR PUS SEE SHEET E5.0 P 01 UTILITY NEUTRAL EARTH GROUND 777.— ii P.O.S. ISOLATED GROUND SYSTEM N.T.S. LINE OF CEILING VIEW 1-0 LEFT OF WINDOW re __ _ T D/T WINDOW ___7 SEE SHEET E5.0 HM (4) 1" DIA. CONDUITS VIEW OF WINDOW M d ISOLATED GROUND OUTLET FOR MONITOR CEED_ — SEE SHEET E5.0 SEE SHEET E5,0 HM 01 SEE 8HEETE5.0 1 WI � ►C CONDUIT IN WALL Cf YP.) SEE SCHEDULE FOR SIZE VIEW TO RIGHT OF WINDOW ISOLATED GROUND OUTLET FOR D/T SYSTEM OUTLET FOR LOW VOLTAGE TRANSFORMER FOR D/T TIMER. P 05 SEE SHEET E5.0 IIM 02 SEE SFIEETE5.0 ISOLATED GROUND OUTLET FOR LOW VOLTAGE TRANSFORMER FOR PCB, S 1 03 ) SEE SHEET E5.0 ISOLATED GROUND OUTLET FOR POS and PRINTER P 01 SEE SHEET E5.0 f_ 04) SEE SHEET E5.0 QUAD OUTLET T 05 SEE SHEET E5.0 V _62 SEESHEETE5,0 REFER TO COMMUNICATIONS SCHEDULE ON SHEET E5.0 FOR EQUIPMENT DESCRIPTIONS/MOUNTING HTS. PHONE: (305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL 0 LL 0 CONTRACT DATE: '10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -YO 7 r E3.1 PLOT DATE: 2008 F.O. 8'-o'1(+168') t 8'-8"(+116-) 1q' -q'-(+180") -4"(+ 26'-4" (+1 31'-4" (+1 -F A. NO CONDUIT SHALL BE FASTENED DIRECTLY TO OR THROUGH ROOFING MEMBRANE. B. ALL CUTS IN ROOFING MEMBRANE SHALL BE MINIMAL AND IN ACCORDANCE WITH ROOFING MFR'S AND INSTALLER'S REQS. C. REFER TO MECH. DWGS FOR MECHANICAL EQUIPMENT ELECTRICAL REQS. D. ALL EXPOSED ELECTRICAL CONDUITS SHALL PENETRATE ROOF MEMBRANE AT PIPE HOODS U.O.N. E. REFER TO ELECT. EQUIP. SCHEDULE AND ELECT. ROUGH -IN PLAN. F. ALL CONDUITS FROM EXHAUST FANS SHALL BE ROUTED INSIDE OF CURB. G. ALL CONDUITS TO AND FROM RTU SHALL BE ROUTED INSIDE OF RTU CURB. COORDINATE WITH RTU MFR RECOMMENDATIONS. H. REFER TO GENERAL NOTES SHEET E2.0 FOR IMPORTANT INFORMATION. I. ALL WIRING AND CONDUITS SHALL BE CONCEALED. NO CONDUITS PERMITTED TO RUN EXPOSED ACROSS ROOF DECK. ROUTE ALL CONDUITS THROUGH EQUIPMENT ROOF CURBS OR ARCHITECT SPECIFIED ROOF PENETRATIONS. J. ALL OUTLETS AND J -BOXES BEHIND SIGNAGE SHALL BE RECESSED OR FLUSH WITH BUILDING FINISH SURFACE. K. SOME BOXES ARE LOCATED WITHIN CONCRETE POURS. INSTALL BOXES AND CONDUIT IN SUCH LOCATIONS PRIOR TO POURING OF CONCRETE. COORDINATE WITH OTHER TRADES. POWER* • PLAN PROVIDE CONNECTION FROM RETURN AIR DUCT SMOKE DETECTORS TO MECH CONTROL CIRCUIT PER DETAIL 2/E6.0, AND FIRE ALARM SYSTEM (IF PRESENT). Q SPECIFIED TRANE RTU IS SUPPLIED WITH THRU THE BASE ELECTRICAL CONNECTIONS AND FACTORY INSTALLED HACK CIRCUIT BREAKER WITH WEATHER TIGHT ENCLOSURES AND ACCESS THRU SWINGING DOOR. Q POWER AND CONTROL ENTRY FROM BOTTOM OF UNIT. ` __) GOOSENECK TERMINATION FOR RESTROOM EXHAUST. FANS ARE CONNECTED TO RESTROOM LIGHTING. SEE SHEET E4.0 AND MECHANICAL SHEETS. 5 1/2" C, WITH REQ'D CONDUCTORS TO J -BOX IN CEILING ABOVE ICE MACHINE. MAKE CONNECTION TO ICE MACHINE AND CONDENSING UNIT. REFER TO POWER PLAN FOR CONTINUATION TO COOLER/ FREEZER. MOUNT PHOTOCELL ON NORTH SIDE OF RTU 2. CONNECT TO EXTERIOR LIGHTING CONTROL PANEL. CD RTU'S SHALL BE PROVIDED WITH BUILT-IN DISCONNECT, SINGLE POINT WIRING AND CONVENIENCE OUTLET-. 9 J -BOX FOR SIGNAGE. COORDINATE LOCATION WITH SIGNAGE VENDOR. SEE SCOPE OF WORK. CIRCUITVIA EXTERIOR LIGHTING CONTROL PANEL. REFER TO DETAIL 8/E6.0. 10 CONTRACTOR SHALL VERIFY CIRCUIT BREAKER TYPE, STARTER, DISCONNECT SWITCH, AND FUSE SIZE (IF REQUIRED) WITH SELECTED EQUIPMENT MANUFACTURER'S SHOP DRAWINGS PRIOR TO PLACING ORDER AND FURNISH AND INSTALL EVERYTHING AS REQUIRED. 11 LED LIGHT STRIP. 12 RAIN SENSOR. 13 PIPE HOOD FOR ICE MACHINE CONDENSERS. 14 TRANSOM LIGHT, SUPPLIED WITH FIXTURE. 15 1 00V LOW VOLTAGE TRANSFORMER SHALL BE PROVIDED WITH LED STRIP LIGHTS. CONTRACTOR TO PROVIDE NEMA 3R ENCLOSURE FOR TRANSFORMER. Y NOTES 0 PHONE: (305) 558-4124 FAX: 305 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHrrECT-AR 2808 ELM AL ffO% Wk N AL & ASSOCIATES electrical engineer • CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL 0 IL 0 CONTRACT DATE: 10-28-2007 BUILDING 'TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -Y07 POWER ROOF PLM!_�' E3. 2 PLOT DATE: 2008 ALL CONDUITS SHALL BE ROUTED ALONG THE TOP CHORD OF • OR •" OF THE ROOF DECK INCORPORATED engineering + architecture. planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: 305 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD, SUITE 333 CORAL CABLES, FLORIDA 33314 PHONE: (30.5) 444-4550 FAX. (305) 444-9696 SEAL LIGHTING PLAN 1/4"=1'-0" I A I CONTRACT DATE: 10-28-2007 GENERAL 140TES A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. B. EMERGENCY AND NORMAL LIGHTING MARKED WITH "NL" SUBSCRIPT SHALL OPERATE CONTINUOUSLY. PROVIDE UNSWITCHED HOTTO NORMAL AND EMERGENCY BALLAST. C. EMERGENCY LIGHTING NOT MARKED WITH "NL" SUBSCRIPT SHALL OPERATE UNDER CONTROL OF LIGHTING SWITCH AS INDICATED. PROVIDE UNSWITCHED CONSTANT HOT TO EMERGENCY BALLAST AND SWITCHED FIOTTO NORMAL BALLAST. D. ALL CONDUITS ENTERING OR LEAVING COOLER/FREEZER SHALL BE PROVIDED WITH SEAL -OFF FITTING WITH COMPOUND PER NEC 300-(7a). E. ALL INTERIOR LIGHTING CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAYS. SEE 14 & 18/E6.0. F. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING HARDWARE. G. ALL FIXTURES SUPPLIED WITH LAMPS. KEY NOTES CONNECT TO EF -4 & EF -5. SEE M2.0 FOR EXACT LOCATION. O FOR LIGHTING FIXTURES, CONDUIT, CONDUCTORS AND INSTALLATION RESPONSIBILITIES, REFER TO SCOPE OF WORK. p FIXTURE AND SWITCH FACTORY INSTALLED WITH UNIT. G.C. TO COMPLETE CIRCUITING. EXHAUST HOOD LIGHT FIXTURES SUPPLIED WITH HOOD AND MTD IN PRE -WIRED J -BOX. COMPLETE CIRCUITING PER DETAIL 2/E6.0. Q COORD. J -BOX LOCATION SO IT REMAINS CONCEALED BEHIND FIXTURE. VERIFY MOUNTING HEIGHT WITH ARCH. DWGS. SOME BOXES ARE LOCATED WITHIN CONCRETE POURS. INSTALL BOXES AND CONDUIT IN SUCH LOCATIONS PRIOR TO POURING OF CONCRETE. COORDINATE WITH OTHER TRADES. CD J -BOX FOR CANOPY LIGHTS. VERIFY POINT OF CONNECTION. WIRE VIA EXTERIOR LIGHTING CONTACTOR. KFC "PUB SIGN": LOCATE OUTLET 8" ABOVE CEILING. LIGHTING NOTES BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 LAMP MOUNTING LAMP MOUNTING NO. QUANTITY LOCATION MANUFACTURER / CATALOG NUMBER DESCRIPTION VOLT WATT REMARKS NO. QUANTITY LOCATION MANUFACTURER / CATALOG NUMBER DESCRIPTION # 'TYPE "TYPE HT. # TYPE TYPE DINING ACCUSERV BLACK CYLINDER 1113016 BOTTOM BLACK CANOPY DINING LOL 4'-0" BLACK TRACK - SURFACE 10'-0" CONNECTOR AS NEED C 4 00533-001 FLUORESCENT 1 U-0" AFF 120 20 5 BLACK CORD KB4 5 6004BK 120 KITCHEN ACCUSERV 2x4 FLUORESCENT 31032%/41 K RECESSED 8'-4" A.F.F. PRISMATIC LENS DINING LOL U-0" BLACK TRACK - SURFACE 10'-0" CUT FROM & TRACK. E 10 & OFFICE 04231-010 3 GRID 120 88 NOTE F KB6 1 6008BK ' - 11'-0" 120 CONNECTOR AS NEED KITCHEN ACCUSERV 2x4 FLUORESCENT 31032/741K RECESSED 8'-4" A.F.F. PRISMATIC LENS DINING LOL U-0" BLACK TRACK - SURFACE 10'-0" CONNECTOR AS NEED EMI 5 SERVING 04231-010 3 GRID 120 88 NOTE F KB8 2 6008BK I20 - KITCHEN THOMAS/DAY-BRITS EMERGENCY BALLAST KIT - - FIELD INSTALL SERVING ACCUSERV DOWNLIGHT FLUOR. UB204 RECESSED 8'-0" W/ FRESNEL LENS TRIM EM1 5 SERVING DEB -1 _ _ _ L I 06211-001 RECESSED 1 HARD CLG. 120 20 RESTRM ACCUSERV 2x4 FLUORESCENT W/ 31032/741K RECESSED 8'-0" A.F.F. PARABOLIC LENS DINING ACCUSERV DOWNLIGHT FLUOR. UB204 RECESSED 10'-O" EM3 2 04231-010 FLANGE KIT 3 FLANGE 120 96 NOTE F L1 15 06211-002 RECESSED 1 120 20 DROP CLG. 11ESTRNI THOMAS/DAY-BRITE EMERGENCY BALLAST KIT - - FIELD INSTALL DINING ACCUSERV DOWNLIGHT FLUOR. UB204 RECESSED 9'-2" EM3 2 DEB -1 - _ _ L2 1 06211-003 RECESSED 1 120 20 HARD CLG. DINING THOMAS/McPHILBEN EMERGENCY LIGHT WALL, TOP 10'-0" A F.F. UNSWITCHED DINING ACCUSERV DOWNLIGHT FLUOR. UB204 RECESSED 10'-0" W/ FRESNEL LENS TRIM EM4 3 CAX6 FROG EYE 2 120 18 'HOT' L3 1 06211-004 RECESSED 1 DROP CLG. 120 20 DINING ACCUSERV LOW VOLTAGE MONOPOIN EXN SURFACE MOUNTING EXTERIOR ACCUSERV 2 -LIGHT UP/DOWN PAR38 WALL 8'-0" TO BOT, METALLIC GRAY FINISH F `1 00119-020 MOUNTED HEAD, BLACK I 120 50 AS DIRECTED M5 10 WALL 5247-001 WALL SCONCE 2 UON ON A4.0 120 250 DINING ACCUSERV LOW VOLTAGE TRACK EXN TRACK MOUNTING EXTERIOR ACCUSERV VAPOR TIGHT INCAND. - SURFACE VARIES, SEE F1 2 00119-019 MOUNTED HEAD, BLACK 1 120 50 AS DIRECTED N 1 5 CANOPIES 00533-007 FIXTURE W/ WIRE GUARD 1 A4.0, A4.1 120 42 KITCHEN THOMAS/McPHILBEN EXIT SIGN, LED WALL 8'-4" A.F.F. EXTERIOR ACCUSERV STRAIGHTARM L163 WALL VARIES, SEE NATURAL ALUM. FINISH U 2 DINING CXXL3RWEM UNIVERSAL MOUNT LED - 120 4 S1 6 WALL 00533-009 WALL FIXTURE 1 A4.0 A4.1 120 100 DINING THOMAS/McPHILBEN EXIT SIGN, LED CEILING TOP @ TOWER ACCUSERV 00259 -KFC L.E.D. SIMULATED NEON L.E.D. WALL 19'-2" (IOP) & COMES IN U LENGTHS GI 1 CXXL3RWEM UNIVERSAL MOUNT LED - 10'-0" AFF 120 4 LR 141 F T. LEON # ACCL88R (RED) 24VDC - 16'-9" (TOP) SEE bHEETA4.1 DINING ACCUSERV SILVER PERFORATED UB204 PENDANT 6-6" A.F.F. H I KF4779 METAL PENDANT 1 120 20 DINING ACCUSERVO KFC "BUCKET' E26 PENDANT 7'-0" A.F.F. J� 4 00277-001 PENDANT 1 120 18 DINING ACCUSERV KFC CYLINDER E26 PENDANT U-0" A.F.F. J6 1 00277-002 PENDANT 1 120 18 DINING LOL BLACK GIMBAL RING L4458 TRACK MOUNTING KB 29 9023BK TRACK HEAD 1 120 75 AS DIRECTED DINING LOL Z-0" BLACK TRACK W/ SURFACE 10'-0" CONNECTOR AS NEED K132 3 6000BK LINE END - 1Z0 - LIGHTING FIXTURE SCHEDULE C ALL CONDUITS SHALL BE ROUTED ALONG THE TOP CHORD OF • OR •" OF THE ROOF DECK INCORPORATED engineering + architecture. planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: 305 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD, SUITE 333 CORAL CABLES, FLORIDA 33314 PHONE: (30.5) 444-4550 FAX. (305) 444-9696 SEAL LIGHTING PLAN 1/4"=1'-0" I A I CONTRACT DATE: 10-28-2007 GENERAL 140TES A. CONFIRM LIGHTING FIXTURE QUANTITIES WITH SUPPLIER. B. EMERGENCY AND NORMAL LIGHTING MARKED WITH "NL" SUBSCRIPT SHALL OPERATE CONTINUOUSLY. PROVIDE UNSWITCHED HOTTO NORMAL AND EMERGENCY BALLAST. C. EMERGENCY LIGHTING NOT MARKED WITH "NL" SUBSCRIPT SHALL OPERATE UNDER CONTROL OF LIGHTING SWITCH AS INDICATED. PROVIDE UNSWITCHED CONSTANT HOT TO EMERGENCY BALLAST AND SWITCHED FIOTTO NORMAL BALLAST. D. ALL CONDUITS ENTERING OR LEAVING COOLER/FREEZER SHALL BE PROVIDED WITH SEAL -OFF FITTING WITH COMPOUND PER NEC 300-(7a). E. ALL INTERIOR LIGHTING CIRCUITS TO BE WIRED THRU THE LIGHTING CONTROL RELAYS. SEE 14 & 18/E6.0. F. CONTRACTOR TO FIELD VERIFY CEILING TYPE AND PROVIDE PROPER MOUNTING HARDWARE. G. ALL FIXTURES SUPPLIED WITH LAMPS. KEY NOTES CONNECT TO EF -4 & EF -5. SEE M2.0 FOR EXACT LOCATION. O FOR LIGHTING FIXTURES, CONDUIT, CONDUCTORS AND INSTALLATION RESPONSIBILITIES, REFER TO SCOPE OF WORK. p FIXTURE AND SWITCH FACTORY INSTALLED WITH UNIT. G.C. TO COMPLETE CIRCUITING. EXHAUST HOOD LIGHT FIXTURES SUPPLIED WITH HOOD AND MTD IN PRE -WIRED J -BOX. COMPLETE CIRCUITING PER DETAIL 2/E6.0. Q COORD. J -BOX LOCATION SO IT REMAINS CONCEALED BEHIND FIXTURE. VERIFY MOUNTING HEIGHT WITH ARCH. DWGS. SOME BOXES ARE LOCATED WITHIN CONCRETE POURS. INSTALL BOXES AND CONDUIT IN SUCH LOCATIONS PRIOR TO POURING OF CONCRETE. COORDINATE WITH OTHER TRADES. CD J -BOX FOR CANOPY LIGHTS. VERIFY POINT OF CONNECTION. WIRE VIA EXTERIOR LIGHTING CONTACTOR. KFC "PUB SIGN": LOCATE OUTLET 8" ABOVE CEILING. LIGHTING NOTES BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -Y07 PLOT DATE: 2008 HOLD-UP BUTTON SHALL BE MOUNTED WITH THE ACTIVATION BUTTOM FACING FO THE SIDE (MOUNT 2-1/211 BEHIND COUNTER EDGE) Q MUSIC SYSTEM SPEAKERS ❑0 SECURITY STROBE 0 J -BOX 2" x 4" J -BOX W/ DATA PORTS QMOTION DEFECTOR QDOOR CONTACT 0 DOOR CONTACT (LINKED TO AUDIO/ C2 VISUAL ALARM) V "SOUND ALERT" DEVICE KP KEYPAD (MTD AT 48" A.F.F.) AS ALARM SIREN ABOVE CLG HBUMP PAD aFS HOOD FIRE SUPPRESSION SYSTEM PULL STATION COMMUNICATIONS LEGEND A. SUPPLY AND INSTALL OUTLETS AND CONDUIT FOR OWNER' UPPLIED AND INSTALLED CABLE AND LOW VOLTAGE WIRING (U.O.N.) TELEPHONE AND MUSIC SYSTEM WIRING SHALL BE SUPPLIED AND INSTALLED. SEE SCOPE OF WORK SHEETS. B. SEE ShTTS. E3.0 AND E3.1 FOR ELECT. INFO ON POS, SECURITY SYSTEM, CCN SYSTEM, (OFFICE) COMPUTER, DRIVE-THRU TIMER AND DRIVE-THRU COMMUNICATION SYSTEM. C. THIS PLAN INCLUDES CONDUITS AND J -BOXES FOR POS, SECURITY SYSTEM, CCN SYSTEM, (OFFICE) COMPUTER, 'TELEPHONE SYSTEM, MUSIC SYSTEM, DRIVE=THRU -TIMER AND DRIVE=THRU COMMUNICATION SYSTEM. D. ALL OUTLETS AND BOXES MOUNTED IN THE SERVING COUNTER CABINETRY ARE TO BE 24" AFF. INSTALL JUNCTION BOXES WITH CONDUIT UNDER CABINET TO NEAREST WALL AND TO ABOVE CEILING. COMMUNICATIONS COMMUNICATIONS IONS PLAN 1/4"=1'-0" PHONE: 305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 3191 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL CONTRACT DA -TE: EQUIPMENTITEM ELEVATION REMARKS COM. # 2007-D SITE NUMBER: 297909 EQUIPMENTITEM ELEVATION REMARKS hl 01 UNDER COUNTER HOLD-UP BUTTON S 03 J -BOX SECURITY SYSTEM +24" A.F.F. 2X4 J -BOX W/ (1) 1/2" CONDUIT TO ABV. CLG. FOR HOLD-UP BUTTON SIGNAL WIRE H U2 WALL MOUNTED HOLD-UP BUTTON +18" A.F.F. 2x4 J -BOX FLUSH MOUNTED IN WALK-IN WALL BY COOLER MANUFACTURER WITFI 1/2" CONDUIT TO OUTSIDE OF COOLER NEAR KITCHEN CEILING. SECURITY SYSTEM INSTALLER TO INSTALL HOLD-UP BUTTON FACING DOWN AND RUN WIRING J -BOX SECURITY SYSTEM +84" A.F.F. 2X4 J BOX W/ COVER & (1) 1/2" CONDUITTO ABOVE CEILING. S 05 J -BOX SECURITY SYSTEM +24" A.F.F. 2X4 J -BOX W/ 3/4" CONDUIT TO ABOVE CEILING. HM 01 D/T J -BOX +96" U.O.N. 4X4X4" DEEP (MIN.) J -BOX BLW. CEILING W/ (1) 2-1/2" CONDUITTO HM -02 & HM -07. SEE GET.16/E3.1 S 06 J -BOX SECURITY SYSTEM +48" A.F.F. 2X4 J -BOX W/ (1) 1/2" CONDUIT TO ABOVE CEILING FOR SECURITY SYSTEM KEYPAD. HM 02 D/T TIMER J -BOX +66" A.F.F. 4X4X4" DEEP (MIN.) J -BOX @ D/T TIMER W/ (1) 2-1/2" CONDUIT TO HM -01 & (1) 1"CONDUIT TO HM -04. SEE DET. 16/E3.1. CS 171) J -BOX SECURITY SYSTEM TOP OF JAMB 2X4 J -BOX W/ (1) 1/2" CONDUIT TO ABOVE CEILING FOR DOOR CONTACT. S 08 "SOUND ALERT" DEVICE B.O.CEILING CONNEGTTO SECURITY SYSTEM. HM 03 D/T BASE STATION J -BOX +72" A.F.F. 4X4 J -BOX @ D/T BASE STATION W/ (1) 1" CONDUITTO HM -08 & HM -04. SEE DEI.16/E3.1. 69 SECURITY STROBE LIGHT B.O. CEILING CONNECT TO SECURITY SYSTEM. HM U4 D/T COMM SYSTEM J -BOX +18" A.F.F. 4X8 J -BOX W/ (1) 1" CONDUIT TO HM -02, (1) 1" CONDUIT TO HM -03, (1) 1" CONDUIT -f0 PICK-UP WINDOW D/T LOOP, AND (3) 1" CONDUITS TO D/T MENU BOARD. SEE DET. 16/E3.1. S 10 ALARM SIREN ABV. CEILING CONNECT TO SECURITY SYSTEM S 11 MOTION DETECTOR +78" STUB 1/2" CONDUIT HM 07 D/T J -BOX D/T J -BOX IRRIGATION TIMER +108" A.F.F. +96" A.F.F. +80" A.F.F. 2X4 J -BOX ABV. CEILING W/ (1) 2-1/2" CONDUIT TO HM -01 & (1) 1" CONDUITTO HM -08. SEE DET. 16/E3.1. 2X4 J -BOX BELOW CEILING W/ (1) 1" CONDUIT TO HM -03 & (1) 1"CONDUIT TO HM -07. SEE DEI -.16/E3.1. 4X4 J -BOX W/ 1" CONDUITTO IRRIGATION VALVES. HM 08 S 12 J -BOX SECURITY DVR +42" A.F.F. 2X4 J -BOX FOR SECURITY DVR. IR U1 (TFOD TELEPHONE SERVICE BOX PER LOCAL TELEPHONE COMPANY. PROVIDE 24"X24"X3/4" PLYWOOD PANEL AT CLG. PROVIDE PULL STRING IN 2" CONDUIT. +48" A.F.F. PROVIDE (1) 25 PAIR TELEPHONE CABLE. ONLY (2) LINES TO BE USED. LINE ONE FOR VOICE/FAX. LINE (2) FOR COMPUTER MODEM. M U1 SPEAKER, CEILING MOUNTED CEILING SPEAKER WIRING FROM SPEAKERS IN DINING ROOM TO AMPLIFIER IN OFFICE. FOR EXACT LOCATION OF SPEAKERS, SEE LIGHTING PLAN SHEET E4.0. T 02 SECURITY SYSTEM PHONE JACK +106" A.F.F. 2X4 J -BOX ADJACENT TO S-02 W/ RJ -31X PHONE JACK. M U3 MUSIC SYSTEM J -BOX +60" A.F.F. 4X4 J -BOX W/ COVER AND W/ 1/2" CONDUIT TO ABV. CEILING FOR MUSIC SYSTEM. FOR RECIEVER, AMPLIFIER & SPEAKERS SEE SCOPE OF WORK T 03 VOICE LINE PHONE JACK +42" A.F.F. 2X4 J -BOX W/ DOUBLE RJ -11 PHONE JACK & 1" CONDUIT TO ABOVE CEILING. T 04 COMPUTER LINE PHONE JACK +42" A.F.F. 2X4 J -BOX W/ RJ -11 PHONE JACK AND 1" CONDUIT TO ABOVE CEILING. O 01 (4) 1" DATA CONDUITS U.G. FROM MENU BOARD/SPEAKER POST TO ABOVE CEILING FOR OCB AND D/T COMM. SYST. SEE DET. 16/E6.0. f 05 POS PHONE JACK +24" A.F.F. 2X4 J -BOX W/ 1" CONDUIT TO ABOVE CEILING. CLOSED CIRCUIT TELEVISION (CCTV) THE STANDARD CCN SYSTEM WILL CONSIST OF (2) CCTV MONITORS, (1) W/ WALL BRACKETS AND (3) MINI -DOME CAMERAS MTD. TO BTM OF MENU BOARD BULKHEAD. P J761 POS J -BOX +24" A.F.F. 2X4 J -BOX W/ 3/4" CONDUIT TO ABOVE CEILING P U2 KITCHEN MONITOR J -BOX @ CLG. 2X4 J -BOX FLUSH a CEILING. FOR M.A.P.S. LINE MONITOR J -BOX (P_F_03) KITCHEN MONITOR J -BOX +84" A.F.F. 2X4X4" DEEP (MIN.) J -BOX W/ (1) 3/4" CONDUITTO ABOVE CEILING. N 01 CCTV MONITOR +126" A.F.F. 2X4 J -BOX W/ (1) 1/2" CONDUIT TO ABV. CLG. P U4 BUMP PAD J -BOX +24" A.F.F. 2X4 J -BOX W/ (1) 3/4" CONDUIT TO P-05. TV 02 SECURITY CAMERA +96" A.F.F. MINI -DOME CAMERA MTD. TO BTM. OF MENU BOARD BULKHEAD. 2X4 J -BOX W/(1) 1/2" CONDUIT TO ABOVE CEILING MTD. ON BACKSIDE OF BULKHEAD. P 05 KITCHEN MONITOR J -BOX +80" A.F.F. 2X4 J -BOX W/ (1) 3/4" CONDUIT TO P-04 AND (1) 3/4" CONDUIT TO ABOVE CEILING. V 01 ALTERNATE PAYMENT ROUTER BOX +90" A.F.F. 4X4 J -BOX W/ 1/2" CONDUIT TO ABOVE CEILING FOR ETHERNET CABLES (DOUBLE JACK) S 01 J -BOX SECURITY SYSTEM +48" A,F,F, 4X4 J -BOX AT SECURITY SYSTEM CONTROL PANEL W/ (1) 2" CONDUIT TO S-02. V 02 CREDIT CARD READER (VSA -f) +24" A.F.F. 2X4 J -BOX W/ 1/2" CONDUIT TO ABOVE CEILING FOR ETHERNET CABLES. S 02 J -BOX SECURITY SYSTEM +106" A.F.F. 4X4 J -BOX ADJACENT TO T-02 W/ (1) 2" CONDUIT TO 5-01. COMMUNICATIONS ROUGH -IN SCHEDULE � PHONE: 305) 558-4124 FAX: (305) 826-0619 EB#0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 3191 JACK D. RAUDENBUSH ARCHITECT -AR 2808 & ASSOCIATES electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL CONTRACT DA -TE: 10-28-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -Y07 A TIONS PLAN PLOT DATE: 2008 TOP OF SLAB ELECTRICAL METALLIC TUBING RIDID STEEL CONDUIT THRU SLAB SLAB SAND GRAVEL EARTH PAD NOTE: GREEN GROUND WIRE REQUIRED IN ALL CONDUITS, SIZED PER N.E.C. REQUIREMENTS. LIGHTING CONTROL SWITCH IN MGR.'S FROM ELECTRICAL PANELS OFFICE OR AS 1 1 l 1 J SHOWN CIRCUIT BREAKER ELECTRICALLY HELD RELAY W/1 20V COIL AND 20AMP CONTINUOUS DUTY "FC' LIGHTING CONTACTS 120V (TYP "PANEL-_" C T T T T _F ) -11 12 13 7\ 14 15 16 17 1 O 0 W Cl p p Co Co Z Z y y Z Z D A i7 � m m z z m m r- W r r - cin m m C m X � m G D C7 > C7 5J NOTE: Om SEE E3.1 FOR LOCATION r La -un; '1 f \ l •' +►i ►`&L: •], ■ :i', -I 1w1y i[m* 4] ►1 II (1) ME 0) CC SEQUENCE OF OPERATION: WHEN SPST SWITCH IS IN THE DOWN POSITION (OFF), RELAY "LC" CONTACTS SHALL ENERGIZE, DISABLING POWER TO THE KITCHEN LIGHTS, SERVING AREA LIGHTS, REST ROOM LIGHTS, WALK-IN REFRIGERATION LIGHTS, AS WELL AS RELAYS "R3" AND "BC"- IN ADDITION: CONTACT LC -7 SHALL ENABLE THE EXHAUST FAN CONTROL RELAY "113" TO SENSE THE "OCCUPIED" OR "UNOCCUPIED" CONDITION (REFER TO DET. 2, SHT E6.0 FOR SEQUENCE OF OPERATION). ACTIVATION OF RELAY "BC" (BLOWER CONTROL) SHALL CAUSE THE CORRESPONDING TERMINALS ON ALL ROOF TOP UNITS TO START THE BLOWERS ON RTU -1 AND 2. EACH RTU BLOWER MOTOR SHALL RUN CONTINUOUSLY UNTIL EITHER "BC" IS DEACTIVATED BY TURNING OFF THE KITCHEN LIGHTS OR WHEN A SMOKE DETECTOR ON AN INDIVIDUAL SHALL SHUT THAT UNIT DOWN INDIVIDUALLY AS REQUIRED BY NFPA. SPST SWITCH IN MGR.'S OFFICE, REFER TO PANEL BOARD OR AS SHOWN. INSTALL SCHEDULES CIRCUIT INVERTED BREAKERS TYP) 7` NORMALLY CLOSED ELECTRICALLY HELD, 120 VOLTAC 20 AMP CONTINUOUS DUTY LIGHTING CONTACTOR LC -11 12 13 14 15 16 , 7 8 120V PANEL "B" CD 7� 7\ n Co M WHERE REQUIRED BY O D n n 24 VAC LOCAL CODE. WIRE TO ® J2-3 —TO RELAY "BC" + Z m m m m G) z z UPON DETECTION OF m r' m m X Co m D MNm 5J Om � � r G) r -c S M "BC" RTU BLOWERC CONTROL RELAY NOTE: SEE E3.1 FOR LOCATION A 10 TYPE I HOOD EXHAUST FAN CONTROL R3� F------ ._._ — -5 ��. _E_ _T -G- (SEE 2/E6.0) -moi °- —�- —R31y j-4— TO DETAIL 3 ON SHEET TO TO E6-� SPARE SPARE RTU -2 RTU -1 r— BC -14 13 12 REFER TO NOTES �FO DETAIL 3 ABOVE ON SHEET E6.0 THIS INTERLOCK SYSTEM IS INTENDED TO MAKE AVAILABLE A FULL VOLUME OF OUTSIDE AIR TO THE BUILDING WHEN ALL EXHAUST FANS ARE ACTIVATED BY THE "OCCUPIED" RELAY. SEQUENCE OF OPERATION: OCCUPIED: ALL KITCHEN EXHAUST FANS SHALL RUN WHEN "R3" IS ENERGIZED INDICATING AN "OCCUPIED" CONDITION, AN AUXILIARY CONTACT IN EACH EXHAUST FAN MOTOR STARTER SHALL CLOSE, TURNING ON THE CORRESPONDING HOOD WORK LIGHTS, INDICATING THAT THE EXHAUST FAN STARTER HAS BEEN ACTIVATED. SPACE THERMOSTAT SENSORS SHALL CYCLE ROOF TOP UNITS TO MAINTAIN "OCCUPIED" SPACE TEMPERATURES. BLOWER MOTORS SHALL OPERATE AS NO -FED IN DETAIL 14, SHT E6.0. UNOCCUPIED: KITCHEN EXHAUST FANS SHALL CEASE OPERATION WHEN RELAY "R3" IS DE -ENERGIZED CORRESPONDING TO TURNING OFF THE LIGHT SWITCH IN THE KITCHEN. SPACE THERMOSTATS SHALL CYCLE ROOFTOP FANS AND HEATING OR COOLING TO MAINTAIN "UNOCCUPIED" SPACE TEMPERATURES. EMERGENCY OPERATION: UPON ACTIVATION OF ANY HOOD FIRE SUPPRESSION RELAY, A RELAY IN THAT FIRE SUPPRESSION SYSTEM SHALL CAUSE THE SHUNT TRIP CIRCUIT BREAKER IN PANEL "H" TO OPERATE, THUS REMOVING POWER FROM ALL DEVICES CONNECTED TO THAT PANEL. EXHAUST FANS SHALL NOT BE AFFECTED BY THIS ACTION AND SHALL CONTINUE TO BE CONTROLLED BY THE "OCCUPIED" OR "NON -OCCUPIED" CONDITIONS LISTED ABOVE. HARDWARE SPECIFICATIONS: HOFFMAN A -HE SERIES WITH HINGED COVER AND CYLINDER KEY LOCK SET. RELAYS: SQUARE -D CLASS 8501, R343, V20 WITH SOCKET BASE. SEE DETAIL 14, SHEET E6.0 ..LC.. C NEUT SEQUENCE OF OPERATIONS: * SET TIME CLOCK FOR THE HOURS THE STORE WILL BE OCCUPIED- COORDINATE WITH OWNER'S REPRESENTATIVE. * ADJUST PHOTOCELL TO ACTIVATE WHEN AMBIENT LIGHT APPROXIMATES DUSK - COORDINATE WITH OWNER'S REPRESENTATIVE * SET BOTH SWITCHES TO THE "AUTOMATIC" POSTITION. SIGNS AND LIGHTS WILL NOW BE ENERGIZED WHEN THE TIME CLOCK INDICATES THE STORE IS OCCUPIED AND THE PHOTOCELL INDICATES LOW LIGHT LEVELS. * WHEN THE STORE CLOSES BUT IS STILL OCCUPIED, THE SIGNS/ BUILDING LIGHTS SWITCH SHOULD BE TURNED TO "OFF" TO EXTINGUISH THESE LIGHTS. * WHEN THE CREW LEAVES THE TIMECLOCK WILL TURN OFF ALL EXTERIOR LIGHTS - THE 30 MINUTE DELAY TIMER IS USED TO PROVIDE POWER TO THE SITE LIGHTS FOR ENOUGH TIME TO ALLOW THE CREW TO LEAVE SAFELY. FAN CONTROL RELAY AFTER COMPLETION AND-IESTING OF THE INTERLOCK SYSTEM SHOWN BELOW, BUT BEFORE PUTTING IT INTO OPERATION, PROGRAM THERMOSTATS FOR RTU1 AND RTU2 TO INITIATE "OCCUPIED" TEMPERATURE SETTINGS AT TIME OF ARRIVAL OF FIRST EMPLOYEE OR MANAGER (APPROXIMATELY 8.-00 A.M.). NOTES: 1. REFER TO THE ELECTRICAL ROOF PLAN, SHEET E3.2 FOR UNIT LOCATIONS AND FURTHER ELECTRICAL REQUIREMENTS. 2. REFER TO THE MECHANICAL SCHEDULES ON SHEET M1.0 FOR ELECTRICAL REQUIREMENTS. RTU TERMINAL STRIP (LTB1) SMOKE DETECTORS LOCATED IN RETURN AIR -REMOVE DUCTS. INCLUDE IN ® 02 JUMPER SUPPLY DUCTS ONLY ®EZ120 WHERE REQUIRED BY n0 L\ 0 09 LTB -3 72A(PR) J1 8 J2-2 24 VAC LOCAL CODE. WIRE TO ® J2-3 —TO RELAY "BC" + SHUTDOWN AC UNITS 01� SHEET E6.0 '10-28-2007 K -y07 2007-D 297909 W750279 J2-5 UPON DETECTION OF 006 ®15 SMOKE. mmm AN 107M ® 131 —1 ALARM CONTACTS 12.5-20 TON VOYAGER UNIT SMOKE DETECTOR NEUT (D-23) 120v SPARE CIRCUIT PAN �—, PHOTOCELL -FORK #2101, MOUNT FACING NORTH. CALIBRATE TO OPERATE WHEN AMBIENT LIGHT APPROXIMATES DUSK. COORDINATE WITH OWNER'S REPRESENTATIVE TIMECLOCK TORK #1101 MOUNT ON WALL ABOVE ENCLOSURE SITE LTS. 20A HAND -OFF - AUTOMATIC (HOA) SWITCH. MOUNT IN ENCLOSURE NORMALLY OPEN ELECTRICALLY HELD RELAY WITH 120V COIL AND 30 AMP CONT. DUTY CONTACTS FOR BUILDING LIGHTS AND SIGNAGE MOUNT IN ENCLOSURE 30 MINUTE TWIST TIMER FOR PARKING LOT LIGHT DELAY MOUNT IN ENCLOSURE 20A HAND -OFF - AUTOMATIC (HOA) SWITCH. MOUNT IN ENCLOSURE NORMALLY OPEN ELECTRICALLY FIELD RELAY WITH 120V COIL AND 30 AMP CONT. DUTY CONTACTS FOR SITE LIGHTS MOUNT IN ENCLOSURE H-27 120V H-27 NEUTRAL PANEL H FEEDER 11 BREAKER INSTALL SHUNT I �I IN CIRCUIT L—� BRFAKER PANELH'PER PANEL H NEUTRAL HOOD FIRE KTINGUISHER CONTACTS 12.5-20 TON VOYAGER UNIT (ROOF TOP UNIT) J1 n0 L\ CTI J2-1 LTB -3 72A(PR) J1 8 J2-2 P7.8 0 J2-3 —TO RELAY "BC" ON DETAIL 14, J2-4 SHEET E6.0 '10-28-2007 K -y07 2007-D 297909 W750279 J2-5 J2-6 COIL TERMINAL OF FAN CONTACTOR —�#64A iwO RELAY'BC" ON DETAIL 14, SHEET E6.0 RTUNFAN INTERLOCK N.T.S. 3 11144CORPORATE® engineering . architecture *planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX: (305) 826-0619 EB//0004432 SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 jut & ASSOCIATES • electrical engineer CA0007454 VICTOR G. MARINA, P.E. ELECTRICAL PE0048539 717 PONCE DeLEON BLVD. SUITE 329 CORAL GABLES, FLORIDA 33314 PHONE: (305) 444-4550 FAX: (305) 444-9696 SEAL KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -YO PLOT DATE: 2008 n0 L\ A 0 0 0 0 CONTRACT DATE: BUILDING -TYPE: PLAN VERSION: SITE NUMBER: STORE NUMBER: '10-28-2007 K -y07 2007-D 297909 W750279 KFC 3601 S ORLANDO DRIVE SANFORD , FLORIDA K -YO PLOT DATE: 2008 I� 2 WAY C.O. T 2 WAY C.O. • ♦ FT -17, SINGLE ONE MANHOLE PER COMPARTMENT — MANHOLE COVER & FRAM L 2 WAY CA, TEE 2 WAY C.O. INLET 2 1/2" MIN. I a I N �0 4 I I N I —-...---� 2/3 LENGTH 1/3 LENGTH BAFFLE REQUIRED TOPS OF INLET AND OUTLET TEES SECTION ARE LEFT OPEN FOR VENTING TEES SHALL BE TWO-WAY CLEANOUT TYPE ALL MAN HOLES AND CLEAN OUTS MUST BE BROUGHT TO GRADE NO SMALLER THAN INLET PIPE MIN. 4" GRADE OUTLET TO SEWER BITUMINOUS EPDXY COATING ON INTERIOR SURFACE TANK MUST BE RATED TO WITHSTAND VEHICULAR TRAFFIC OIL & GREASE INTERCEPTOR DETAIL Q (PER CITY OF SANFORD UTILITY DEPARTMENT) EXIST. FIRE HYDRANT TO REMAIN SITE UTILITY PLAN NOT PLATTED COMMERCIAL ESTABLISHMENT GRAPHICGRAPHIC SCALE ( IN FEET ) 1 inch = 20 ft, SEPARATOR OR INTERCEPTOR PLAN VIEW NOTE: DEPTH WILL VAY ACCORDING TO THE DEPTH OF THE SEWER SERVICE. SEMINOLE CENTRE PLAT BOOK 62, PAGES 39-40 IJ CENTERUISIE 15' WATERLINE EASEMENT, ORB 1795, PG.142 CT /� a f� -t- EXIS 6" SAN SEV, LATERAL POINT OF CONNEC T)N AT EXIST. LATRAL �---�- TRASH ENCLOSURE SAAB TO BE 6" MIN ABU`,E SURROUNDING GRaQS SEWER SAMPLING BOX 0 MANHOLE COVER LABEL AS "SAMPLING BOX" n .4 . 6" RUBBER BOOT TYPE co 36' 48' SECTION VIEW Q 2 SEWER SAMPLING BOX PER CITY OF SANFORD UTMIDL DEPARTMENT) -11 ° w h c CONCRETE / FLUME EXIST. 10"0 S N SEWER SEMINOLE CENTRE e:::� PLAT BOOK 62, PAGES 39-40 LOT 2 / NOTES: 1. ALL HYDRANTS TO FALL WITHIN 2 FEET OF CURB, STEAMER CONNECTION TO FACE ROADWAY. 2. LANDSCAPING SHALL NOT OBSCURE FIRE HYDRANT NOR SPRINKLER STANDPIPE WYES. 3. BUILDING ADDRESS SHALL BE CLEARLY VISIBLE FROM ROADWAY. 4. ALL GLEAN—OUT IN �RNFFI EWAYS TO HAVE TRAC BEARING CAPS USC 7605 VALVE BOX). 5, ON—SITE SANITARY SEWER TO BE PRIVATELY 14AINTAINED. 6, CONTRACTOR TO VERIFY INVERTS AND EXACT LOCATION OF UTILITIES PRIOR TO COMMENCING WITH WORK. 7.. MINIMUM SLOPE OF SANITARY WASTE = 19:. 8. CONTRACTOR TO PROMDE CLEANOUTS AT EACH CKANGE OF DIRECTION OF SEWER UNE AND AT INTERVALS NOT TO EXCEED 70FT. 9. NO SOLVENT WELD SHALL BE USED. f7K GRON Im INCORPORATED engineering • architecture .planning 15500 NEW BARN ROAD SUITE 106 MIAMI LAKES, FLORIDA 33014 PHONE: (305) 558-4124 FAX (305) 826-0619 EBEB#0�32 cl� SEAL EDUARDO L. CARCACHE CIVIL ENGINEER -PE 31914 JACK D. RAUDENBUSH ARCHITECT -AR 2808 NO. DATE DESCRIPTION Q 4-16-08 CITY 6-18-08 CITY -UTILITY DEPT, 0 Q 0 CONTRACT DATE: 10-18-2007 BUILDING TYPE: K -y07 PLAN VERSION: 2007-D SITE NUMBER: 297909 STORE NUMBER: W750279 DRAWING DATE: 3-11-2008 KFC 3601 S ORLANDO DRIVE SANFORD, FLORIDA K -y07 SITE UTILITY' LAN C-3 PLOT DATE: 2008