Loading...
112 French Ave - BC12-001439 (MCDONALD'S) (REMODEL - REVISION) (A)1 4t4\ JUL I o 2012 REVIS PERMIT ft DATE PROJECT ADDRESS CONTRACTOR PHONE # 1/,D9 - 8 FAX tf 7 YS"/ CONTACT' PERSON 5 -1-e- v e— DESCRIPTION OF REVISION e dc -,q, e- e- UTIM,rY DEPT FIRE PREVENTION PLANNING BUILDING i FRENCH 1 V E N U E REVISION HISTORY REVISION NO. DATE REVISION TYPE NOTES 1 5/24/2012 INTERIOR COORDINATION REMOVED EXISTING CEILING FIXTURES, SOFFITS, TILE & GRID AT DINING ROOM & CREW ROOM - A0.1, MD1.0, ED4.0 -- -- -- - _� ADDED NEW CEILING FIXTURES, SOFFITS, TILE & GRID AT DINING ROOM & CREW ROOM - A1.1, M1.0, E4.0 E ADDED FURNITURE LAYOUT PER INTERIOR DRAWINGS & REVISED EGRESS PATHING & DATA - A0.5, A1.1 _ m _ _ `1 ADDED INTERIOR DESIGN DRAWINGS - REFER TO INDEX THIS SHEET co N REVISED ELECTRICAL LOAD CALCULATIONS - E1.1 Ci N N -- cU _ -- McDONALUS FRENCH AVENUE - REMODEL BUILDING INFORMATION: ADDRESS: STATE SITE CODE: 009-1303 STREET ADDRESS: 112 FRENCH AVENUE_ CITY: SANFORD COUNTY: SEMINOLE STATE- FLORIDA ZIP CODE: 32771 STRUCTURE 8" MASONRY & STEEL LOAD BEARING WALLS, STEEL ROOF FRAMING UTILITIES: SPLIT UTILITIES: ELECTRIC GRILLS & ELECTRIC FRYERS, HVAC & WATER HEATER BUILDING CODES-.- GOVERNING ODES:GOVERNING JURISDICTION: SANFORD, FLORIDA BUILDING CODE EDITION: FLORIDA BUILDING CODE 2010 FLORIDA EXISTING BUILDING CODE 2010 FLORIDA BUILDING CODE /ACCESSIBILITY 2010 MECHANICAL CODE EDITION: FLORIDA MECHANICAL CODE 2010 ELECTRICAL CODE EDITION: NATIONAL ELECTRICAL CODE 2008 (NFPA 70) PLUMBING CODE EDITION: FLORIDA PLUMBING CODE 2010 ADDITIONAL CODE EDITIONS: FLORIDA FIRE PREVENTION CODE 2010 NFPA 101 -LIFE SAFETY 2006 NFPA 1 - UNIFORM FIRE CODE 2006 BUILDING DATA: ROOF PLAN OCCUPANCY: USE GROUP A2 NORTH-EAST ELEVATIONS CONSTRUCTION TYPE: VB SOUTH-EAST ELEVATIONS NUMBER OF STORIES: 1 WALL SECTIONS BUILDING HEIGHT: 17'-11" (MAIN BLDG. PARAPET) WALL SECTIONS 19'-11" (HEARTH PARAPET) WALL SECTIONS EXISTING BUILDING AREA: 3,093 GROSS S.F. ENLARGED RESTROOM PLAN, AREA OF ADDITION: 275 SQ. FEET SCHEDULES & DETAILS NEW GROSS BUILDING AREA: 3,368 S.F. DETAILS COMPLIANCE METHOD: ALTERATION LEVEL 3 x DESIGN LOADS: VELOCITY: 140 MPH IMPORTANCE FACTOR: I = 1.0 EXPOSURE.- EXPOSUREC � INTERNAL PRESSURE COEFFICIENT: +/-0.18 X BUILDING CATEGORY: II I LIFE SAFETY SYSTEM: EMERGENCY LIGHTING: X YES NO O w F- EXIT SIGNS- X YES NO FIRE ALARM AND SMOKE DETECTION X SYSTEM (KITCHEN EQUIPMENT): X YES NO PANIC HARDWARE: X YES NO V FIRE SPRINKLERS.- YES X NO DESIGNER OF RECORD: ARCHITECT: John A Baer, AIA 500 W. Fulton Street 407.322.6841 CPH Engineers, Inc. Sanford Florida 32771 N 4 v N a CIVIL: Justin Polk, PE 500 W. Fulton Street 407.322.6841 CPH Engineers, Inc. Sanford Florida 32771 STRUCTURAL: Harold Higgenbotham, PE 322 Corrine Dr., Suite F 407.304.7721 Higgenbotham Structural Engineers Orlando, FL, 32707 X -- MECHANICAL, Bradley W. Perrot 130 Candace Dr. 407.740.5020 PLUMBING & Matern Professional _Engineering, Inc. Maitland, Florida 32751 z (') ELECTRICAL 0) M N CONSTRUCTION PROJECT MANAGER: MANAGER: Tim Chess 10150 Highland Manor Dr. Ste. 470 813.630.9634 Tampa, FL 33610 (D BUILDING PERIVIIT SUBMITTAL j REVISION LOG DRAWING INDEX 4 CS COVERSHEET X - G0.1 GENERAL INFORMATION GO.2 ADA REQUIREMENTS & DETAILS ARCHITECTURAL A0.0 DUMPSTER ENCLOSURE S2.1 DETAILS A0.1 DEMOLITION PLAN A0.2 DEMOLITION ROOF PLAN A0.3 DEMOLITION ELEVATIONS A0.4 DEMOLITION ELEVATIONS A0.5 LIFE SAFETY PLAN A1.0 FLOOR PLAN A'1.1 REFLECTED CEILING PLAN A1.2 ROOF PLAN A2.0 NORTH-EAST ELEVATIONS A2.1 SOUTH-EAST ELEVATIONS A3.0 WALL SECTIONS A3.1 WALL SECTIONS A3.2 WALL SECTIONS A4.0 ENLARGED RESTROOM PLAN, x SCHEDULES & DETAILS A5.0 DETAILS STRUCTURAL S1.1 NEW FOUNDATION PLAN S2.1 NEW ROOF FRAMING PLAN S3.1 STRUCTURAL NOTES 34.1 STRUCTURAL SECTIONS S4.2 STRUCTURAL SECTIONS S4.3 STRUCTURAL SECTIONS S4.4 STRUCTURAL SECTIONS S4.5 STRUCTURAL SECTIONS MECHANICAL M0.0 GENERAL NOTES, LEGENDS MD1.0 FLOOR DEMO PLAN MD1.1 ROOF DEMO PLAN M'1.0 FLOOR PLAN M1.1 ROOF PLAN M3.0 DETAILS PLUMBING P0.1 GENERAL NOTES, LEGENDS PD1.0 DEMO FLOOR PLAN P1.0 FLOOR PLAN ELECTRICAL E0.1 GENERAL NOTES, LEGENDS E0.2 SITE PLAN - POWER ED1.0 DEMO FLOOR PLAN - POWER ED4.0 FLOOR DEMO PLAN - LIGHTING ED4.1 ROOF DEMO PLAN - LIGHTING & POWER E1.0 FLOOR PLAN - POWER E1.1 ROOF PLAN - POWER E4.0 FLOOR PLAN - LIGHTING E4.1 ROOF PLAN - LIGHTING & POWER INTERIOR t I I o X -- X X w X w U b�'" < ,, X 1 X X�� X x X - x X � X I ID -CS COVER SHEET ID -1 PROPOSED REFRESH UPDATES ID -2 RECOMMENDED LIST REFRESH ITEMS ID -3 DEMO FLOOR PLAN ID -4 WALL FINISH PLAN ID -5 RESTROOM FINISH PLAN ID -6 GRAPHIC WALL PLAN ID -7 FLOOR PLAN ID -8 FLOOR FINISH PLAN ID -9 CEILING PLAN ID -10 BEFORE & AFTER PHOTO -SIDE DINING VIEW IDA'I GRAPHIC DETAIL - QUALITY 2 - FV16 ID -12 GRAPHIC: DETAIL - QUALITY 2 - FV18 ID -13 GRAPHIC DETAIL - QUALITY 2 - FV12 ID -14 GRAPHIC DETAIL - QUALITY 2 - FV10 ID -15 GRAPHIC DETAIL - QUALITY 2 - FV19 (A&B) ID -16 GRAPHIC DETAIL - QUALITY 2 - FV21 ID -17 GRAPHIC DETAIL - QUALITY 2 - FV20 ID -18 SITE PHOTOS ID -19 SITE PHOTOS X t I I o X -- X w X w U b�'" < ,, X 1 X�� z 0 x x X � X I X O w F- X V X X x, N 4 v N a w aLo❑ - X X -- Uj0 W w W w C� o Q z (') X 0) M N v CEO 500 West Fulton .Street Sanfoird, Florida 32771 P O. B -1- 2808 Sanfordi-Florida 32772-2808 Pilolte 407 322-6841 Fax 407 330-0639 �Engineers surveyors ��rc`l1tG4tSYf� .,�, Planners ; Landscape Architects Environmental Scientists C'i anstructi.on Management Traffic/ Trans po rta ti o 1t i Eng. O.A. No. 3215 Sury y L.B. No. 7143 Areb. L c. No. AA2600926 Landscp,! Lic. No. LC0000298 2072 I j t I I o �a w �� w U b�'" < ,, W 1L 1 C f wZ CERTIFICATION (D Cn TO THE BEST OF THE ARCHITECT'S Z KNOWLEDGE INFORMATION, AND BELIEF, THIS DESIGN IS IN C Mr 1 IANCE WITH APPLICABLE DE' AND L/1,W,9. IQ j MAY 2 � ��1� ,,;.. - , : Sheet No. JOHN A. E , AIA. DATE CS 000-130 .., i NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE" TO REPRODUCTION I I T >7] I W 1L z 0 z 0 0 � I O w F- z N 4 v N a w aLo❑ a�aaaaaz Uj0 W w W w C� o Q z (') N d 0) M N v (D G Q �> s U c� o ai w) o U a� C f wZ CERTIFICATION (D Cn TO THE BEST OF THE ARCHITECT'S Z KNOWLEDGE INFORMATION, AND BELIEF, THIS DESIGN IS IN C Mr 1 IANCE WITH APPLICABLE DE' AND L/1,W,9. IQ j MAY 2 � ��1� ,,;.. - , : Sheet No. JOHN A. E , AIA. DATE CS 000-130 .., i NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE" TO REPRODUCTION FREEZER 1. 115 COOLER 114 D STORAGE/, ,O�/ /CREW OM/ 11014— rrT GENERAL DEMOLITION REQUIREMENTS THE FOLLOWING REQUIREMENTS FOR DEMOLITION, CUTTING AND PATCHING APPLY TO ALL WORK WHICH IS ALTERED, WHETHER SUCH WORK IS NEW, EXISTING, RENOVATED OR REPLACED: PRIOR TO DEMOLITION, CUTTING AND PATCHING, THE CONTRACTOR SHALL LOCATE AND DISCONNECT UTILITY SERVICES AND ELECTRICAL / MECHANICAL SYSTEMS, OR TEMPORARILY CAP OFF SUCH SERVICES TO THE AFFECTED AREAS. GIVE NOTICE'T0, AND COORDINATE WITH UTILITY COMPANIES. OBTAIN WRITTEN APPROVAL FROM, AND COOPERATE WITH OTHER PARTIES WHO MAY BE AFFECTED BY INTERRUPTION OF SERVICES. CLEARLY MARK THE AREAS AND LIMITS OF DEMOLITION, CUTTING AND PATCHING. IF FEASIBLE, PRE-CUT THE LINE OF SEPARATION BETWEEN AREAS OF DEMOLITION AND AREAS TO BE PRESERVED. UTILIZE DEMOLITION AND CUTTING TECHNIQUES WHICH ARE LEAST LIKELY TO DAMAGE SURROUNDING OR ADJOINING WORK. WHERE FEASIBLE, USE HAND -TOOLS AND SMALL POWER TOOLS THAT ARE DESIGNED FOR SAWING AND GRINDING, NOT HAMMERING OR CHOPPING. DO NOT USE EXPLOSIVES. STRUCTURAL REQUIREMENTS: DO NOT CUT AND PATCH STRUCTURAL WORK IN A MANNER WHICH WILL REDUCE LOAD -CARRYING CAPACITY OR LOAD -DEFLECTION RATIO. WHERE STRUCTURAL WORK MUST BE CUT, PROVIDE ADEQUATE TEMPORARY SUPPORT (BRACING AND/OR SHORING) TO RESIST VERTICAL, LATERAL AND DYNAMIC LOADS IN THE ENTIRE TRIBUTARY AREA OF THE AFFECTED STRUCTURAL MEMBERS. WHERE REQUIRED, ENGAGE A LICENSED STRUCTURAL ENGINEER TO DESIGN SHORING / BRACING SYSTEMS AND JOINT OR CONNECTION DETAILS. 4 1 1 20 SUPPORT 113 PREPERATION 112 TORAGE 109 OPERATIONAL AND SAFETY LIMITATIONS: DO NOT CUT AND PATCH OPERATIONAL ELEMENTS OR SAFETY RELATED COMPONENTS IN A MANNER WHICH WILL REDUCE INTENDED PERFORMANCE OR SAFETY FACTOR, OR WHICH WILL RESULT IN INCREASED MAINTENANCE OR REDUCED OPERATIONAL LIFE. VISUAL REQUIREMENTS: DO NOT CUT AND PATCH WORK IN A MANNER WHICH WILL RESULT IN LESSENING OF THE AESTHETIC QUALITIES OF THE BUILDING OR SITE, OR THAT WILL RESULT IN VISUAL EVIDENCE OF CUT AND PATCH WORK. WHERE REQUIRED, EXTEND FINISH MATERIALS OVER ENTIRE UNBROKEN SURFACE AREAS AFFECTED BY CUT AND PATCH WORK. REMOVE AND REPLACE CUT AND PATCH WORK WHICH DOES NOT MEET VISUAL REQUIREMENTS. PROTECTION: PROTECT OTHER WORK DURING CUTTING AND PATCHING OPERATIONS TO PREVENT DAMAGE. PROVIDE PROTECTION OF ALL WORK FROM ADVERSE WEATHER CONDITIONS. WHERE OPENINGS ARE CREATED IN ROOF OR EXTERIOR WALLS, PROVIDE TEMPORARY ENCLOSURE OF SUCH OPENINGS ON A DAILY BASIS, AND WHENEVER ADVERSE WEATHER THREATENS OR EXISTS. ORDER 108 20 1 12 14 3 I ' III � -1 h H 6 1 1 1 / / / �i.. TI i/' /i/ /// /// /// /// i� / / // / / 'i'ii / / / / // / / / /ii//// // "1 I' /'/i i• ' /, i i�l IIS 103 / Z 13 Z Z z / / // i/d i�/ / // // // // /// /1// /// 0 ori/ /I/ //// / /// / // // /// /// / // // / / // / // / ///' / / / / 100 / / / / // /�/ /� r i / /// //, / /// /// / r/ / / / // T/ /� '///'/ /' 21 / �l // /z / ,rte �f// //' /' / //// 101 / /' / / / /, 13 Ny I//I/ 16 2 �f / / / / // / i 17 22 / // / // / /// // /, // // / // / // /// M(v's'i/ /, , //// /// //"// 'f' z1//� // / 100 404//// 9 I f i/// /// /i�i� 0 o -/i / 21 22 MANAGER / / / / / 1 5 HAND 106 / /, / /// / // SINK I �//// //�/ ////// 22,///,I 3 /F- Z_ L�/_J//////// '/ /// /////// // /// // 18 / / / 8 PRESENTER 107 DEMOLITION NOTES 1. REPAIR & PATCH WALLS WHERE NECESSARY TO MATCH & TO RECEIVE PAINT/WALL PAPER 2. FIELD VERIFY ELECTRICAL DEMOLITION WITH MCDONALD'S CONTRACTOR 3. THE CONTRACTOR MAY DETERMINE THAT THE COST OF REMOVAL & REPLACEMENT OF EXISTING WALLS IS LESS EXPENSIVE THAN KEEPING EXISTING WALLS. IT IS THE CONTRACTOR'S PREROGATIVE TO DEMO EXISTING WALLS AT NO ADDITIONAL EXPENSE TO THE OWNER 4. CONTRACTOR TO FIELD VERIFY SUBSTRATES BELOW FLOOR FINISHES FOR ANY CONDITIONS THAT MAY AFFECT THE COST OF INSTALLATION OF THE SPECIFIED MATERIAL 5. CLEAN & LEVEL FLOOR AS REQUIRED IN DEMO OR SPECIFIED AREAS 6. CONTRACTOR TO DISPOSE OF ANY ITEMS THE OWNER DETERMINES ARE NOT ACCEPTABLE FOR RE -USE. ALL MEASUREMENTS INDICATED ON THE PLAN SHALL BE VERIFIED ON THE ACTUAL CONDITION. ANY DISCREPANCY IN THE MEASUREMENT SHALL BE REPORTED TO THE ARCHITECT BEFORE THE START OF DEMOLITION. DO NOT SCALE DRAWINGS. ALL MEASUREMENTS INDICATED ON THE PLAN SHALL BE VERIFIED ON THE ACTUAL CONDITION. ANY DISCREPANCY IN THE MEASUREMENT SHALL BE REPORTED TO THE ARCHITECT BEFORE THE START OF DEMOLITION. F-] KEYNOTES REMOVE EXISTING STOREFRONT, FRAME AND HARDWARE. WALL BELOW STOREFRONT TO REMAIN. CLEAN & PREP FOR NEW METAL STUD INFILL OR NEW WINDOW. REFER TO FLUOR PLAN & ELEVATIONS. REMOVE EXISTING STOREFRONT, FRAME, HARDWARE AND WALL E] L BELOW STOREFRONT.STOREFRONT.REFER TO FLOOR PLAN &ELEVATIONS. 3� REMOVE EXISTING STOREFRONT DOOR, FRAME & HARDWARE. REMOVE EXISTING WINDOW. CLEAN & PREP FOR NEW METAL STUD INFILL. REFER TO FLOUR PLAN & ELEVATIONS. EXISTING MENU BOARD VALANCE TO BE MODIFIED. COORDINATE W/ NEW MENU BOARD LAYOUT. Z11 EXISTING STEEL COLUMN TO REMAIN. aREMOVE EXISTING GUARDRAIL. z 8 EXISTING SSBB TO REMAIN. V-1.. REMOVE ALL EXISTING LIGHT FIXTURES, HVAC GRILLS, CEILING "FILES, & GRID. 10 REMOVE EXISTING WALL (V.I.F.) - REFER TO SHEET A4.0 HREMOVE ALL EXISTING RESTROOM ACCESSORIES 12 R OVE ALL EXISTING PLUMBING FIXTURES 13 EXISTING LOW WALL TO BE REMOVED. 14 REMOVE EXISTING GYPSUM CEILING & LIGHT FIXTURES. — - — C = = = _:_ =_ = — — = C = _ _._.. . _ — — — — — BUILDING PERMIT SUBMITTAL 500 WestFulton Street Satlfoird, Floriclu 32771 P., U. Bux 2808 Satlfordi.Florida 32772--2805 Pllu� e 407 322-6841 Fax 407 330-0639 �.Erlgineers ,Sul veyors t'chitect9 1"lanners Landjcape Architects tzvtrot�rnental Scientists construction Matiagelnent Traffic) Transportation Eng. �.O.A. No. 3215 Survey L.B. No. 7143 Arch. Linc. No. AA2600926 Landscp: Lic. No. LC0000298 (D20-12 �a DEMOLITION PLANN w U) SCALE: 1/4" =1'-0" 4► a) T SYMBOLLEGEND o 15 RELOCATE PLUMBING FIXTURE. REFER TO A1.0 EXISTING WINDOW / STOREFRONT TO BE DEMOLISHED ALL FLOOR DRAINS TO REMAIN. COVER & PROTECT DURING r 16 DEMOLITION. REFER TO PLUMBING. 17 REMOVE CUSTOMER SERVICE COUNTER / III EXISTING DOOR TO BE DEMOLISHED � III 18 EXISTING ICE TOWER TO REMAIN O z — — O REMOVE EXISTING GLASSBLOCK WALL. CLEAN & PREP FOR NEW METAL U 1 J STUD INFILL. REFER TO FLOOR PLAN & ELEVATIONS. TO REMAIN %////////// BE 20 EXISTING WINDOW/ STOREFRONT AREA OF EXISTING CEILING TO O DEMOLISHED 21 REMOVE EXISTING COLUMN. F - _ Z 22 REMOVE EXISTING . OFFIT N O F- _ _ _ _ ] EXISTING WALL TO BE DEMOLISHED � ❑ 23 EXISTING LOW WALL 0 REMAIN -REFER TO INTERIOR DECOR w 11 'i<I FOR NEW FINISHES. <I (�` ,n0�� � Z I EXISTING WALL TO REMAIN 1009-13031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE c 0 M .7 a) (L' NO b � LL E C4 w fn LL Lu L Lu >- Z Z W > 0 ww <0j LL heet No. �O e REPRODUCTION Z 0 r Ei O O U 0 R w F - Z N r 4 N � ❑ 11 'i<I <I Z ,n0�� � Z � • c) O N � m a c 0 0 E h ) v 7 p Q �I j O < Q) (0 ni o Z � a LL NO b � LL E C4 w fn LL Lu L Lu >- Z Z W > 0 ww <0j LL heet No. �O e REPRODUCTION _- - - -� I I BUILDING PERMIT SUBMITTAL 86' 91 FLOOR PLAN N SCALE: 1/4" = V-0" T_T�_EXIST. JOIST (FYP.) 3-5/8"'18 GA. MTL. ' STUD HORIZ. BRACE BETWN. Z JOISTS @ 6-0" O.C. MAX. - ATTACH TO TOP JOIST W/ (1) #10 TEK SCREW EA. END 1/2" GYP BD OR PLYWOOD — BACKUP EACH SIDE AS INDICATED ON FINISH SCHEDULE 18 GA CONT, TRACK ATTACHED TO CONC. SLAB W/ (2) 0.145 P.A.F. @ 24" O.C. MAX. ATTACH EA. STUD TO TRACK W/ (1) #10 TEK SCREW EA. SIDE BOTTOM 6" OF BACKUP TO BE CEMENT BD. - MIN. 1/2" ABOVE SLAB - EXIST. CONC. .� SLAB ---- " 18 GA CONT. TOP TRACK - ATTACH TO EA. HORIZ. BRACE W/ (1) #10 TEK SCREW, & TO EA, STUD W/ (1) #10 TEK SCREW EA. SIDE NOTE: CLG. AS I WALLS WITHIN 2 FEET OF WATER SCHEDULED CLOSETS, URINALS & HAND SINKS SHALL BE CEMENT BOARD TO 4 FEET A.F.F. WALL TAG CHART O FLOOR AS SCHEDULED MTL. STUD PARTITION TYPE: ALL PARTITIONS TYPE 'A' UNLESS NOTED OTHERWISE "A" = 3 5/8" "A1"= 3 5/8" W/BATT INSULATION B611 "B'1"= 6" W/BATT INSULATION .1c., = 8" "C'1"= 8" W/BATT INSULATION STUD SPACING: '16" O.C. LOAD BEARING 24" O.C. NON -LOAD BEARING STUD GAUGE: LOAD BEARING: 18 NON -LOAD BEARING: 20 INTERIOR PARTITION SCALE: 3/4" =1'-0" DOOR SCHEDULE MARK DOOR EXISTING WALL TO PRESERVE N FRAME NOTE MATERIAL SIZE TYPE MATL SIZE 1 ALUM. 3'-0" x T-0" x 1 3/4" A ALUM. 2" JAMB & HEAD 2 S.C. WOOD T-0" x 7'-0" x 1 3/4" B STL 2" JAMB & HEAD 24" X24" LITE (TEMPERED) 3 1 S.C. WOOD 3'-0" x 7'-0" x 1 3/4" B STL 2" JAMB & HEAD 24" X24" LITE (TEMPERED) DOOR HARDWARE DOOR #'1 1. CLOSER: LCN 4021 x 18 2. HINGES: OFFSET PIVOT ANSI -A-156.4 GRADE 1; PROVIDE EXPOSED PARTS OF CAST ALUMINUM ALLOY, AS SUPPLIED BY DOOR MANUFACTURER. 3. PUSH/PULL HANDLE: KAWNEER #CO -9 OR HAGER #164DNIB 4. THRESHOLD: NATIONAL GUARD PRODUCTS, INC. SADDLE TYPE THRESHOLD 325, 36" WIDE x1/2" RISE (ADA ACCESSIBLE). 5. WEATHER STRIPPING: PROVIDE COMPRESSION WEATHER STRIPPING AGAINST FIXED STOPS. AT OTHER EDGES PROVIDE SLIDING WEATHER STRIPPING RETAINED IN ADJUSTABLE STRIP MORTISED INTO DOOR EDGE. PROVIDE EPDM OR VINYL GASKET WEATHERSTRIPPING IN BOTTOM DOOR RAIL ADJUSTABLE FOR CONTACT W/ THRESHOLD. ,U. ALUM. IR TEMP. ZING 0" STILE \T BOTTOM 0 DOOR #2 - PASSAGE DOOR 1. CLOSER: 4031-LCN PULL SIDE MOUNTED 2. HINGES: HAGER BB1279 US 26D 4 1/2" x4 1/2" - 1-1/2 PAIR OR EQUAL. 3. PUSH & PULL PLATE: PUSH -HAGER 30S 4X16 US 28; PULL -HAGER FI -33E 4X16 PLATE US 28 4. WALL STOP: HAGER 236W 5. KICK PLATES: US28D SATIN, ALUM. 8" x 34" x 18 GA. (2) PER DOOR 6. DOOR SILENCERS: HAGER, QUANTITY = 3 7. SAFETY GUARDS: FINGER SAFE MKIA OPEN HINGE SIDE AND MKIB CLOSED HINGE SIDE OF DOOR. DOOR #3 - PASSAGE DOOR 1. HINGES: HAGER BB1279 US 26D 4 1/2" x 4 1/2" - 1-1/2 PAIR OR EQUAL. 2. PASSAGE HARDWARE GENERAL NOTES 1. THE PLAN LOCATION OF FIXTURES AND EQUIPEMNT AND ARE INTENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE AND LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL FOR EVERY AND ALL OF THE ACCESSORIES IN -FENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORK. 2. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE ARCHITECT RESERVES THAT RIGHT TO DIRECT THE REMOVAL AND REPLACEMENT OF ANY ITEM, IN HIS OPINION THAT DOES NOT PRESENT AN ORDERLY AND REASONABLY NEAT OR WORKMANLIKE APPEARANCE. THE REMOVAL AND REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE GENERAL CONTRACTOR AND WITHOUT ADDITIONAL COST TO THE OWNER. 3. THE CONTRACTOR SHALL COMPLY WTFH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS. 4. PATCH AND REPAIR ALL AREAS AFFECTED BY RENOVATION TO MAINTAIN THE INTENDED USE AND IN FULL SATISFACTION OF SPECIFICATIONS AND WARRANTIES OF (AFFECTED ITEM/S) MANUFACTURER. 5. CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS, DIMENSIONS, AND ELEVATIONS PRIOR TO FABRICATIONS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO FABRICATIONS AND CONSTRUCTION. ❑ KEYNOTES CM NEW CMU WALL/INFILL SW SCREEN WALL. COORDINATE LOCATION & LENGTH WITH EXISTING KITCHEN EQUIPMENT EC EXISTING STEEL COLUMN TO REMAIN ED EXISTING HOLLOW METAL DOOR - PAINTED TO MATCH NEWADJACENT BUILDING COLOR. CSR NEW ALUMINUM GUARD RAIL - REFER TO DET. *12/A5.0 FH - EXISTING HANDSINK MB NEW MENU BOARD LEGEND ---q>WALL TAG MS NEW 8" METAL STUD INFILL Q NS NEW CONCRETE SLAB - REFER TO STRUCTURAL LW EXISTING LOW WALL - REFER TO INTERIOR FOR NEW FINISHES OWNER TO VERIFY NEW SHELVING IN SH STORAGE AREA SS EXISTING SSBB T'1 48" x T ALUMINUM TRELLIS W/ SLOPED INFILL PANELS AND W/ TIE BACKS T2 2" x 8" ALUMINUM WALL FASCIA. EXACT LENGTH TO BE VERIFIED ONSITE. T3 36" x 18" ALUMINUM CANOPY W/ SLOPED INFILL PANELS AND W/ "FIE BACKS COLOR: YELLOW W'1 NEW EXTERIOR WINDOW ASSEMBLY TAT = TEMPERED GLAZING HEXISTING EXTERIOR WINDOW ASSEMBLY. 500 Wml Sarzf ht Floriatt 32771 1,, O. Box 2808 Saufoul, Florizla 32772--2808 Plto�ze 407 322-6841 Fax 407 330-0639 �Brtgirteers ;Surveyors rchitCcts 111artrters Landf l cape Architects .Envir'orlrrteutal scientists C'ortstractlon Martageruertt Traffic%Transportation I Eng. O.A. IV o. 3215 Sury a L.B. No. 7143 Arch. L c. No. AA2600926 Lurtdscp. Lic. No. LC0000298 (D2012 N -0 C 0 0 N 4 w N i Ln I O <71 Z EXISTING WALL TO PRESERVE N � NEW METAL STUD WALL / INFILL CD o NEW CMU WALL / INFILL ❑ KEY NOTE QDOOR TAG ---q>WALL TAG MS NEW 8" METAL STUD INFILL Q NS NEW CONCRETE SLAB - REFER TO STRUCTURAL LW EXISTING LOW WALL - REFER TO INTERIOR FOR NEW FINISHES OWNER TO VERIFY NEW SHELVING IN SH STORAGE AREA SS EXISTING SSBB T'1 48" x T ALUMINUM TRELLIS W/ SLOPED INFILL PANELS AND W/ TIE BACKS T2 2" x 8" ALUMINUM WALL FASCIA. EXACT LENGTH TO BE VERIFIED ONSITE. T3 36" x 18" ALUMINUM CANOPY W/ SLOPED INFILL PANELS AND W/ "FIE BACKS COLOR: YELLOW W'1 NEW EXTERIOR WINDOW ASSEMBLY TAT = TEMPERED GLAZING HEXISTING EXTERIOR WINDOW ASSEMBLY. 500 Wml Sarzf ht Floriatt 32771 1,, O. Box 2808 Saufoul, Florizla 32772--2808 Plto�ze 407 322-6841 Fax 407 330-0639 �Brtgirteers ;Surveyors rchitCcts 111artrters Landf l cape Architects .Envir'orlrrteutal scientists C'ortstractlon Martageruertt Traffic%Transportation I Eng. O.A. IV o. 3215 Sury a L.B. No. 7143 Arch. L c. No. AA2600926 Lurtdscp. Lic. No. LC0000298 (D2012 N -0 C 0 0 N 4 w N i Ln I O <71 Z � N � CD o c0 r= -� ¢ C:) a c m a `o Q o � Q w .. 7 Q �I O aj z o W CL in o 'u= Q -5 Sheet No. X1.0 1009-13031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION BUILDING PERMIT $UBMITTAL 1 .181-51, 86-9-,"' NEW L4x4x3/8 STEEL SUPPORT ANGLES COORDINATE HEIGHT OF STAND W/ CONDENSER SIZE TO BE BELOW FINISHED PARAPET HEIGHT ROOF TOP COOLER CONDENSERS ATTACHED WITH #14 TEK SCREWS & GALVANIZED L -BRACKETS TO NEW ALUMINUM STAND NEW ALUMINUM STAND BY "ALUMISTAND AND VIBRA-DAMP CORPORATION OF AMERICA" ATTACHED TO DECK WITH '1/2" DIAMETER BOLTS PER MANUF. SHOP DWGS. NEW BAR JOISTS; TYPICAL NEW '1/2" THICK COVER BOARD EXISTING ROOF SYSTEM EQUIPMENT RACK DETAIL N.T.S. 60 MIL. SINGLE -PLY TPO MEMBRANE PERIMETER SHEET METAL FASTENER PLATE W/ FASTENERS @12" O.C. �- PARAPET PRE -FABRICATED ANCHOR -TITS FASCIA 60 MIL. SINGLE -PLY TPO MEMBRANE SHEET - MECHANICALLY FASTENED SYSTEM EXISTING ROOF SYSTEM ROOFING DETAIL N.T.S. (AT EXISTING ROOF) ROOFING SYSTEM (AT 10'-011 EXTENSION) 1 ❑ KEYNOTES 1. MANUFACTURERS AND PRODUCTS: A. CARLISLE SYNTEC INCORPORATED: SURE -WELD TPO ROOFING SYSTEM B. JOHNS MANVILLE ULTRAGARD SRT -60 C. FIRESTONE ULTRA -PLY 2. SPECIFIED ROOFING SYSTEMS (AS SHOWN): HEAT -WELDABLE SINGLE -PLY 60 MIL TPO ROOFING SYSTEM, INSTALLED OVER RIGID INSULATION ON METAL ROOF DECK HAVING A SLOPE OF 1/4"/FT. MATERIALS SHALL BE AS FOLLOWS: A. TPO ROOFING SYSTEM AS MANUFACTURED BY ONE OF THE TWO MANUFACTORS LISTED ABOVE TO COMPLY WITH ASTM D-6878, AND FMG 1-90 FOR WIND UPLIFT. B. FASTENERS: METAL FASTENERS AND PLATES AS PER MANUFACTURE. C. ACCESSORIES: PRE -FABRICATED CURBS, FLASHING, CORNERS, TERMINATION BARS, PIPE FLASHING, VENT FLASHING ETC. AS PER MANUFACTOR. 3. WALKWAYS: A. 34" WIDE WALKWAY ROLL, HOT AIR WELDED TO MEMEBRANE. WIDTH AS PER MANUFACTURER. B. PROVIDE WALKWAY FROM ROOF LADDER EXIT TO ROOF TOP UNITS AS PER ROOF PLAN ABOVE. GENERAL ROOFING NOTES 1. SINGLE -PLY ROOFING SYSTEM WITH BASE FLASHING SHEET EXTENDING UP PARAPET AND TERMINATED UNDER COPING HOT WELDED TO SEALING STRIP SECURED TO WOOD BLOCKING 2. INSTALLATION OF ROOFING SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND PER DETAIL 2 OF THIS SHEET. 3. PROVIDE PREFABRICATED METAL CURBS. COORDINATE SIZE, LOCATION AND INSTALLATION REQUIREMENTS W/ M, E, P & S SHEETS.PROVIDE CURB LEVELER IN AREAS WHERE ROOF DECK IS PITCHED. C. INSTALL WALKWAY ACCORDING TO WALKWAY PAD MANUFACTURER'S WRITTEN INSTUCTION. 4. RIGID INSULATION: PROVIDE REQUIRED LAYERS OF POLYISOCYANURATE INSULATION W/ COVER BOARD TO MEET A R-30 VALUE - -THICKNESS AS REQUIRED. PROVIDE POSITIVE SLOPE TO ROOF DRAINS (3/8" PER FOOT MIN.) REFER TO ROOF PLAN. PROVIDE TOP LAYER PROTECTION MATERIAL AS PER MANUFACTURERS RECOMMENDATIONS. BOTTOM LAYER OF INSULATION OVER 5/8" TYPE "X" EXTERIOR GRADE GYPSUM BOARD. ASSEMBLY TO COMPLY WITH UL '1256 OR FMG 4450. ALTERNATE BOTTOM LAYER: INSULATION WITH INTERGRAL THERMAL BARRIER OR APPROVED ROOFING MANUFACTURER'S THERMAL UNDERLAYMENT SHEET. 5. TAPERED INSULATION: 6. EXHAUST HOODS: PROVIDE ADDITIONAL ROOF MEMBRANE AROUND EXHAUST HOODS AS INDICATED PER ROOF PLAN ABOVE. NOTE: FLORIDA APPROVAL #11300.8 FOR SINGLE PLY TPO ROOF SYSTEM 4. FOR EXACT LOCATION OF EXHAUST FANS, FIVAC UNITS, AND ROOF HATCH. REFER TO STRUCTURAL DRAWINGS. 5. CRICKETS MUST BE INSTALLED AT ALL HVAC UNITS EXHAUST FANS AND COMPRESSOR RAILS, BY GENERAL CONTRACTOR. 6. ALL WOOD USED ON ROOF DECK TO BE PRESSURE TREATED. EC EXISTING RTU CURB E� EXISTING METAL GUTTER/ DOWNSPOUT, PAINT TO MATCH ADJACENT BUILDING COLOR EL EXISTING ROOF ACCESS LADDER, PAINT TO MATCH ADJACENT BUILDING COLOR EQ EXISTING ROOF TOP EQUIPMENT 'r0 REMAIN ER NEW EQUIPMENT RACK - REFER TO 2/A1.2 METAL FASCIA BY METAL -ERA COLOR: CITYSCAPE LIGHT FIXTURE (WALL SCONCE) - REFER TO ELECTRICAL [L]A LIGHT FIXTURE (ARCADE LIGHT) - REFER TO ELECTRICAL NG NEW GUTTER & DOWNSPOUT. NQ NEW ROOF TOP UNIT. REFER TO MECHANICAL HNEW ROOF ASSEMBLY. REFER TO 3/A1.2 GENERAL NOTES: RE1 30'-0" ROOF CAP ELEMENT - REFER TO ELEVATIONS AND SECTIONS RFS DRIVE TRHU HEARTH ROOF CAP ELEMENT - REFER TO ELEVATIONS AND SECTIONS RJ EXISTING ROOF JOISTS. VERIFY IN FIELD EXACT LOCATION EXISTING ICE TOWER CONDENSER UNIT RELOCATED RU FROM PREVIOUS RACK - REFER TO MECHANICAL McDONALD'S SIGNAGE - REFER TO ELEVATIONS Fsl & SECTIONS SW NEW SCREEN WALL WITH CORRUGATED METAL PANELS BY METAL ERA: 7/8" "S" 24 GUAGE PANEL COLOR: CITYSCAPE IT148"x8" ALUMINUM TRELLIS WITH ANODIZED ALUMINUM 11 PANEL INFILL WITH POSITIVE SLOPE FOR DRAINAGE & W/ TIE BACKS T2 2"x8" ALUMINUM WALL FASCIA. LENGTH TO BE SITE VERIFIED. F336"x'18" ALUMINUM CANOPY WITH ANODIZED ALUMINUM PANEL INFILL WITH POSITIVE SLOPE FOR DRAINAGE & W/ TIE BACKS - COLOR: YELLOW 1. THE PLANS SHOW THE LOCATION OF FIXTURES AND EQUIPMENT AND ARE IN -FENDED TO CONVEY THE GENERAL INTENT OF THE WORK IN SCOPE AND LAYOUT. THEY ARE NOT INTENDED TO SHOW IN MINUTE DETAIL FOR EVERY AND ALL OF THE ACCESSORIES INTENDED FOR THE PURPOSE OF EXECUTION OF THE WORK, BUT IT IS UNDERSTOOD THAT SUCH DETAILS ARE PART OF THIS WORK. 2. ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED IN A NEAT AND FIRST CLASS WORKMANLIKE MANNER. THE ARCHITECT RESERVES THAT RIGHT TO DIRECT THE REMOVAL AND REPLACEMENT OF ANY ITEM, IN HIS OPINION THAT DOES NOT PRESENT AN ORDERLY AND REASONABLY NEAT OR WORKMANLIKE APPEARANCE. THE REMOVAL AND REPLACEMENT SHALL BE DONE WHEN DIRECTED BY THE GENERAL CONTRACTOR AND WITHOUT ADDITIONAL COST TO THE OWNER. TP NEW TPO ROOFING MEMBRANE OVER 1/2" COVERBOARD OVER EXISTING ROOF - REFER TO 1/A1.2. ADD A 34" WIDE LAYER OF TPO MEMBRANE FOR WALK PATH FROM ROOF ACCESS TO EQUIPMENT, AND A 24" WIDE LAYER AROUND RTU's & FRYER EXHAUST FANS. TR TAPERED INSULATION WM EXTEND WATERPROOFING MEMBRANE UP BACK, AND OVERTOP OF NEW PARAPET WALL - REFER TO WALL SECTIONS & DETAILS. XF EXISTING COOLER/FREEZER ROOF 3. THE CONTRACTOR SHALL COMPLY WITH THE MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS TO THE EXTENT PRINTED INFORMATION IS MORE DETAILED OR STRINGENT THAN REQUIREMENTS CONTAINED DIRECTLY IN THE PLANS. 4. PATCH AND REPAIR ALL AREAS AFFECTED BY RENOVATION TO MAINTAIN THE INTENDED USE AND IN FULL SATISFACTION OF SPECIFICATIONS AND WARRANTIES OF (AFFECTED ITEM/S) MANUFACTURER. 5. CONTRACTOR SHALL FIELD VERIFY ALL SITE CONDITIONS, DIMENSIONS, AND ELEVATIONS PRIOR TO FABRICATIONS AND CONSTRUCTION. CONTRACTOR SHALL NOTIFY ARCHITECT AND ENGINEER OF ANY DISCREPANCIES PRIOR TO FABRICATIONS AND CONSTRUCTION. son 500 West Fulton Street Sanford, Florida 32771 _,'. 0. Box 2808 Sanforll, Florida 32772-2808 Phone 407 322-6841 Fe ix 407 330-0639 Engineers Surveyors Architects 1'Citntters Landscape. Architects %atvirUrltrienter l Scientists ('onstrite tion Managetnent Traff i! 17'ratisportation Eng.; C. 0.A. No. 3215 Survey L.B. No. 7143 Arch. Lic. No. AA2600926 Lattdscp. Lic. No. LC0000298 20:12 z 0 c V 7 1- tr J 0 as 7- 0 0 f- Z 0 0 0 ry 0 fy w z N_ 4 N � � Q Q aaaaz c�A w u m Q o z CO co 0-) C) � a o z D ca D > L_ U Q ai cA 0� o Z -0 �I a� ILL Sheet No. Al 1 009-1 3031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION r C Q T a C i i ENLARGED RESTROOM -FIXTURES AND ACCESSORIES PLAN SCALE: 1/2" =1'-0 RESTROOM ACCESSORY SCHEDULE ITEM MODEL # SUPPLIER BACKUP SUPPORT (REFER TO NOTE 2) REFER TO NOTE 3 G GRAB BAR 42" 812-001-42 UNIVERSAL MFG. (1) 2x6'S 4'-0" LONG CENTER 800-821-'1414 MOUNTED 1 B GRAB BAR 36" 812-001-36 NOTES 1) REFER TO G0.1 FOR ACCESSORY MOUNTING HEIGHTS 2) SELECT ONE ITEM FROM ITEM GROUPS 4 & 6 3) CUT BACK-UP SUPPORTS BETWEEN STUDS SO FACE OF SUPPORT IS FLUSH W/WALL STUD PARTITION AS INDICATED ON FLOOR PLAN D. "PRO SET" CORIAN VANITY TOP SUPPORT BY 2" ALL SIDES WITH TURNED -DOWN H MFG. CO. 22?/ EDGES AS SHOWN WITH11 Jl Col D ARMS AND 8" MIN. ON PLATE: 0 FOR SINGLE EL 0700D FOR 'O -- --- ---- --1 `li j l" ADX PLYWOOD SUBSTRATE - VERIFY WITH COUNTER TOP MANUFACTURER. z ADA -COMPLIANT z u UNDERSINK PIPING � Q PROTECTION OVER PIPES - REFER TO `4 PLUMBING PROVIDE 5" CORIAN SKIRT AT OPEN SIDES OF LAVATORY LAVATORY SECTION DETAIL FLOOR MT TOILET TISSUE DISPENSER, 5412 BRADLEY (2) 2x6'S 2'-6" LONG 2 O DOUBLE, RECESSED JAY R. SMIT '1 -800 -BRADLEY OSANITARY NAPKIN RECEPTACLE, RECESSED 4731-15 BRADLEY MARK ROOM NAME (OPTIONAL) 800-272-3539 MODEL 070 BASE HAND DRYER, RECESSED, ADA, RA5Q-974 UNIVERSAL MFG. (1) 2x10 V-4" LONG 4A WHITE - OTHER COLORS AT DBL. SIDED 800-821-1414 O 0 ADDITIONAL COST n er7 LL 4B TOWEL DISPENSER & WASTE RECEPTACLE, INDIVIDUAL, 2441 BRADLEY w >- F- RECESSED (OPTIONAL) 3251 800-272-3539 U) TOWEL DISPENSER & WASTE ¢ BRADLEY` z w 7) 4C RECEPTACLE, COMBINATION, 2291 800-272-339 N RECESSED (OPTIONAL) I #781 UNIVERSAL MFG. 5) MIRROR, ANGLE FRAME 24"x36" 800-821-1414 z0 w z '1 DISPENSER, w UNIVERSAL MFG. L OSOAP WALL -MOUNTED 6542 800-821-1414 C14 w 71 BABY CHANGING TABLE, ui ❑ FRAME WALL RECESS PER O HORIZONTAL, RECESSED, ADA KB100-MDRA KOALA KARE CORP. MANUFACTURER'S COMPLIANT 800-666-0363 RECOMMENDATIONS > [o DIAPER CONTAINER 8 (OPTIONAL) - BY OWNER NOTES 1) REFER TO G0.1 FOR ACCESSORY MOUNTING HEIGHTS 2) SELECT ONE ITEM FROM ITEM GROUPS 4 & 6 3) CUT BACK-UP SUPPORTS BETWEEN STUDS SO FACE OF SUPPORT IS FLUSH W/WALL STUD PARTITION AS INDICATED ON FLOOR PLAN D. "PRO SET" CORIAN VANITY TOP SUPPORT BY 2" ALL SIDES WITH TURNED -DOWN H MFG. CO. 22?/ EDGES AS SHOWN WITH11 Jl Col D ARMS AND 8" MIN. ON PLATE: 0 FOR SINGLE EL 0700D FOR 'O -- --- ---- --1 `li j l" ADX PLYWOOD SUBSTRATE - VERIFY WITH COUNTER TOP MANUFACTURER. z ADA -COMPLIANT z u UNDERSINK PIPING � Q PROTECTION OVER PIPES - REFER TO `4 PLUMBING PROVIDE 5" CORIAN SKIRT AT OPEN SIDES OF LAVATORY LAVATORY SECTION DETAIL FLOOR MT ROOM FINISH SCHEDULE LAVATORY �- < z O JAY R. SMIT o OR EQUAL u CONCEALE MARK ROOM NAME ESCUTCHE MODEL 070 BASE p SIDED;MOD � C114 O v DBL. SIDED WALLS O 0 ❑ n er7 LL CEILING C__)� * O w >- F- REMARKS k SEE CEILING PLAN FOR HGTS & LAYOUTS U) iY Lu z ¢ z w 7) IJ U) ».: N 1w Jw I a <1 <1<61 z0 w z '1 z w LLA L J -0 0�� Z N r C14 w 71 U) ui SCALE: 1" =1'-0" 1/2" CORIAN ADA NOTES ADA REQUIRED CLEAR SPACE TURNAROUND 60" DIAMETER B❑ ADA REQUIRED CLEAR FLOOR AREA 60" x 60" aADA REQUIRED CLEAR FLUOR AREA 30" x 48" ADA REQUIRED CLEAR FLOOR AREA 42" x 54" ADA SIGNAGE - EXISTING TO REMAIN LEGEND EXISTING WALL TO PRESERVE NEW WALL - REFER TO A1.0 X❑ KEY NOTE TAG 2'-6" 1/2" PLYWOOD 2X WD. BLOCKING 6" MTL. STUD @ 16" U.C. FRP OVER'1/2" PLYWOOD ON KITCHEN SIDE SIN 1/2" PLYWOOD ti CV 2X WD. BLOCKING CONT. RUNNER ANCHOR TO - FLOOR w/ 1 1/2" SHORT PINS @ 48" O.C. FLOOR FINISH AS SCHEDULED RESTROOM ACCESSORY TAG d' ELI Mill' COUNTERTOP SECTION SCALE: 1 1/2" =1'-0" 1/2" TEMP GLASS WI LOGO SEALANT 1/2" CORIA 1/2" PLYW 2X WD. BL 8" MTL. Sl 1/2" PLYW 2X WD. BL FRP OVEF KITCHEN FLUOR Al i BUILDING PERMIT SIUBMITTAL i GENERAL NOTES O= RESTROOM ACCESSORY - REFER TO X RESTROOM ACCESSORY SCHEDULE 1. ALL DIMENSIONS SHOWN ARE TAKEN FROM FACE OF GYP. BD. - FIELD VERIFY AND ADJUST AS NEEDED TO ENSURE COMPLIANCE WITH ADA REQUIREMENTS. 2. REFER TO SHEET A4.0 FOR PARTITION TYPES. 3. REFER TO SHEET A1.0 FOR DOOR SCHEDULE. 4. REFER TO G0.2 FOR ACCESSORY MOUNTING HEIGHTS. 5. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST PERMA-SIGN 1-800-214-8765 9292 1 ST ST., BOX 588 www.forrestpermasigns.com NEW ROCHELLE, NY 10802 6, ALL HAND SINK LOCATIONS SHALL HAVE CEMENT BOARD BACKING 48" IN HEIGHT A F F • 500 west Fulton Street Sanfoird, Florida 32771 Y' U. Vo,r 2808 Sanford,1.Florida 32772-2808 PhoPe 407 322-6841 Fa407330-0639 ;.Engineers surveyors Architects I Planners Land calve Architects Eirviror mental Scientists C'orastruction AV anagemerat Traffic/ Transportation Eng. O.A. No. 32:15 Surv�y L.B. No. 7143 Arch. Lac. No. AA -9600926 L.andscf)l Lic. No. LC0000298 20.12\ 7. COORDINATE ALL REQUIRED BLOCKING FOR WALL c HUNG FIXTURES FOR PROPER INSTALLATION C_ HFIGHTS NOTE:COUNTER SUPPORT WALL FURNISHED & INSTALLED BY G.C. INTERMEDIATE SUPPORTS SUPPLIED & INSTALLED BY KES. 1/2" CORIAN NOTE: ALL ITEMS ARE PROVIDED AND INSTALLED BY G.C. ITE: 1/2" CORIAN )UNTER TOP TO IERHANG ON -CHEN SIDE OF \LL BY 1/2". 1/2" CORIAN 'CORIAN CONT. GALV. RUNNER ANCHOR TO FLUOR w/ 1 1/2" SHORT PINS a 48" U.C. COUNTERTOP SECTION SCALE: 1 1/2" =1'-0" ROOM FINISH SCHEDULE �- < z O o I u i <f MARK ROOM NAME FLOOR O BASE p OLL � C114 O v Uj1 WALLS O 0 ❑ n er7 LL CEILING C__)� * O w >- F- REMARKS k SEE CEILING PLAN FOR HGTS & LAYOUTS U) iY Lu z ¢ z w 7) IJ U) ».: N 1w Jw I a <1 <1<61 z0 w z '1 z w LLA L J -0 0�� Z N r C14 w 71 U) ui ❑ w - Q w z w ZZ > [o 0 2, w W Q > z a_ �I Z w < D � L! 111 I-_ w W z O z m Z Gl Z Z z Q Z Z O Z F- > Q W m 0 CL > Q m Z W Cl Iw- O U) J ° 7 > p m 0 W w -1 II - 0 I - O � 7 IL a w Q a -i z cn w W � a- < w Z w O � Q w _j 0O m m O ¢ cn U F� v1 _ F- }~ I- C7 z d F- u C7 Z° > r Z> w z w U W J Q U Z V] OU z m Q Z 0 1 _j C7 Z O U Q I- O W Cl W J < I- U (A O O W U W F- S Q I- 7I O - O Q 1 a X > O > O Z ¢ X a �- W CK W 0Y 2E w W w w � w W w X U W i� x Z Q ` W w Z Q ° m X LL ° w 0 U> w� cD w w U cn U U a w� N a. N a w� w 100 CUSTOMER SERVICE COUNTER • • • • • • • • VERIFY FINISHES WITH DECOR COMPANY 101 DINING ROOM • • • • • • • VERIFY FINISHES WITH DECOR COMPANY 102 WOMEN'S • • • • • VERIFY FINISHES WITH DECOR COMPANY 1U3 MEN'S • • • • • VERIFY FINISHES WITH DECOR COMPANY 110 CREW ROOM • • • • • • • VERIFY FINISHES WITH DECOR COMPANY GENERAL FINISH NOTES 1. ALL FINISH SURFACES OF WALL AND CEILING MATERIALS SHALL BE CLASS II AND SHALL HAVE A FLAME SPREAD RATING OF 26 TO 75 AND A SMOKE DENSITY OF 450 MAX. (PER IBC TABLE 8A). 2. DECORATIVE MATERIAL SHALL NOT CONCEAL EXITS, EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS, AND EXTINGUISHER LOCATIONS 3. FLOOR TILE: 1) MUST BE APPROVED BY McDONALD'S U.S. RESTAURANT DESIGN & CONSTRUCTION DEPARTMENT 2) MUST BE NO LARGER THAN 12"X12" 3) MUST MEET THE FOLLOWING: STATIC COEFFICIENT OF FRICTION (PER ASTM F1677-05): LEVEL SURFACES: MINIMUM 0.50 DRY AND WET 4. PROVIDE CEMENT BOARD BACKER OR EQUIVALENT AT ALL CERAMIC TILE LOCATIONS. 1/2" CORIAN ADA NOTES ADA REQUIRED CLEAR SPACE TURNAROUND 60" DIAMETER B❑ ADA REQUIRED CLEAR FLOOR AREA 60" x 60" aADA REQUIRED CLEAR FLUOR AREA 30" x 48" ADA REQUIRED CLEAR FLOOR AREA 42" x 54" ADA SIGNAGE - EXISTING TO REMAIN LEGEND EXISTING WALL TO PRESERVE NEW WALL - REFER TO A1.0 X❑ KEY NOTE TAG 2'-6" 1/2" PLYWOOD 2X WD. BLOCKING 6" MTL. STUD @ 16" U.C. FRP OVER'1/2" PLYWOOD ON KITCHEN SIDE SIN 1/2" PLYWOOD ti CV 2X WD. BLOCKING CONT. RUNNER ANCHOR TO - FLOOR w/ 1 1/2" SHORT PINS @ 48" O.C. FLOOR FINISH AS SCHEDULED RESTROOM ACCESSORY TAG d' ELI Mill' COUNTERTOP SECTION SCALE: 1 1/2" =1'-0" 1/2" TEMP GLASS WI LOGO SEALANT 1/2" CORIA 1/2" PLYW 2X WD. BL 8" MTL. Sl 1/2" PLYW 2X WD. BL FRP OVEF KITCHEN FLUOR Al i BUILDING PERMIT SIUBMITTAL i GENERAL NOTES O= RESTROOM ACCESSORY - REFER TO X RESTROOM ACCESSORY SCHEDULE 1. ALL DIMENSIONS SHOWN ARE TAKEN FROM FACE OF GYP. BD. - FIELD VERIFY AND ADJUST AS NEEDED TO ENSURE COMPLIANCE WITH ADA REQUIREMENTS. 2. REFER TO SHEET A4.0 FOR PARTITION TYPES. 3. REFER TO SHEET A1.0 FOR DOOR SCHEDULE. 4. REFER TO G0.2 FOR ACCESSORY MOUNTING HEIGHTS. 5. GC TO PROVIDE ADA SIGNAGE PACKAGE AND INSTALL SIGNS AT LOCATIONS AND POSITIONS INDICATED OR AS REQUIRED BY LOCAL CODES. SIGNAGE PACKAGE SUPPLIED BY: FORREST PERMA-SIGN 1-800-214-8765 9292 1 ST ST., BOX 588 www.forrestpermasigns.com NEW ROCHELLE, NY 10802 6, ALL HAND SINK LOCATIONS SHALL HAVE CEMENT BOARD BACKING 48" IN HEIGHT A F F • 500 west Fulton Street Sanfoird, Florida 32771 Y' U. Vo,r 2808 Sanford,1.Florida 32772-2808 PhoPe 407 322-6841 Fa407330-0639 ;.Engineers surveyors Architects I Planners Land calve Architects Eirviror mental Scientists C'orastruction AV anagemerat Traffic/ Transportation Eng. O.A. No. 32:15 Surv�y L.B. No. 7143 Arch. Lac. No. AA -9600926 L.andscf)l Lic. No. LC0000298 20.12\ 7. COORDINATE ALL REQUIRED BLOCKING FOR WALL c HUNG FIXTURES FOR PROPER INSTALLATION C_ HFIGHTS NOTE:COUNTER SUPPORT WALL FURNISHED & INSTALLED BY G.C. INTERMEDIATE SUPPORTS SUPPLIED & INSTALLED BY KES. 1/2" CORIAN NOTE: ALL ITEMS ARE PROVIDED AND INSTALLED BY G.C. ITE: 1/2" CORIAN )UNTER TOP TO IERHANG ON -CHEN SIDE OF \LL BY 1/2". 1/2" CORIAN 'CORIAN CONT. GALV. RUNNER ANCHOR TO FLUOR w/ 1 1/2" SHORT PINS a 48" U.C. COUNTERTOP SECTION SCALE: 1 1/2" =1'-0" C 0 Q= �- < z O o I u i <f d. ,U),I O p OLL � C114 O v Uj1 C 0 Q= heet No. �4mO 1009-13031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION z O I d. ,U),I O p OLL � C114 O IJ Uj1 O 0 ❑ n er7 LL CC C__)� Lu O w >- F- U) iY Lu z ¢ z w 7) IJ U) ».: N 1w Jw I a <1 <1<61 z0 w z '1 z w LLA L J -0 0�� Z N r C14 w 71 U) w E 0 2, p ltr 0 > �I C? UJ D � L! heet No. �4mO 1009-13031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION J d. ,U),I O OLL � C114 O IJ Uj1 O ❑ n er7 LL CC C__)� Lu w >- F- U) < ¢ z w 7) IJ U) ».: 7 O 1w Jw LL z0 w z Q LIJ T Q L J C) C14 w 71 U) w heet No. �4mO 1009-13031 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION E C7 Z W Z 0 V) Q Of Q_ z ry o a 1 1 1 1 11 J 10`1 9i r-� P•v r+J`•;>a,' E R 1:J 0 �r- IF -Ef " I C 1/VC7f41cP.i' FLOOR . PLAN - MECHANICALt 0 ­_­------------ _­___ III � ___--__-------------------- -----------_____ B 725 TO D-1 ON II 1 HAN[ SINK 2 r 1 I I I 1 ! K LJ 250 1 - - --'-r� 8"0 12" 11,! � I Ill � I --- I I1! J•�•1� iT _ _ -------------- - I, I9! I j �•�� B i i ii I'0 I 14'0 1 725 1 1 ii I K it ilt (ON ROOF) I > _ �.. _I _ 500 1 1 250 iii j I----------------- I 11! ir- I� I _-_.----------------VIII I II i l I j 11 I 8" I I1! 0 I L 4b 11 600 K 1 I _ r -f L----------- i i ( i --------------- ______ - 12" 0 TO DT1 ON R09 / ry A-2 �- fir---� � K u 500 250 1 1 HEX NOTES O REMOVE EXIST. SA AND RA DUCT RISERS UP TO ROOF. BUILDING PERMIT SUBMITTAL GENERAL NOTES 1. ALL EXISTING MECHANICAL EQUIPMENT AND DUCTWORK NOT WITHIN SCOPE OF WORK IS NOT SHOWN. 500 West Fulton Street Sanford, Florida 32771 P. O. Box 2808 Sanford, Florida 3277,E-2808 Phone 407 322-6841 Fax 407 330-0639 Engineers Surveyors Architects Planners Landscape Architects Environmental Scientists Construction Management Traffic/ Transporta tion Eng. C.O.A. No. 3215 Survey L.B. No. 7143 Arch. Lie. No. AA2600926 Landscp. Lie- No. LCOW0298 © 2012 ,e r4�. G E NqA'•. t�:A EL w Si'i��rV"A��E� U J z Z0 m f0 0 >n��pQQyj CU cc (nW U n wiz � -.—�o-v�W uj._ Qccz "z 0.6 z M5 0 cv 0 �k m 0 3 ul (L 2 92 Sheet No. MD 1w U'O"" MCDONALD'S PROJECT CODE: 009-1303 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION z O Q z QP U IX O W; 0 V) E' cV N O Q a a a<1 <1 Q z IY 11= N 07 co CE m - CD N r- a Cj -O 7 a of 0 N C: C: D U cD D o Q a� cn 0 O Z -0 o o CA W u_ - Sheet No. MD 1w U'O"" MCDONALD'S PROJECT CODE: 009-1303 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION wa n !I II II II II II II II i' II II II !I II II II II II II II II II II II II II II II II II II II II II II II II 1! II II U II II it II II II it ii II II II it I� II II II II II II II it i = ---- ��_-_==J-_Jt - - =----- ----==--=W-- �-----____-____====fit _______=�_�=��W_=---______�_�'I FLOOR PLAN - MECHANICAL 1/4" =1'-0" � 0 2' 4' 8, VP in ® I� 4 w Z M � :3Va _j c) w LU w > zz () HEX NOTES GENERAL NOTES z X LU O 1. ALL EXISTING MECHANICAL EQUIPMENT NOT WITHIN SCOPE OF WORK IS NEW DIFFUSER/GRILLE SHALL BE PAINTED BLACK FROM THE FACTORY TO NOT SHOWN. �Z MATCH NEW DECOR PACKAGE. 2. REFER TO MANUFACTURER'S RECOMMENDATIONS FOR ALL REFRIGERANT ® 1111110 C4 w O CONNECT NEW GRILLES TO EXISTING BRANCH DUCTS. PIPE SIZES ACCORDING TO FINAL LENGTH OF RUN, 0Malmo 3, ALL DUCTWORK SHALL BE RUN BETWEEN OR THROUGH THE JOISTS UL O ADD TRANSFER GRILLE WITH 10" DUCT CONNECTION BETWEEN SPACES. UNLESS NOTED OTHERWISE. DUCTWORK DESIGNATED WITH (B.J.) SHALL efto BE RUN BELOW THE JOISTS. BUILDING PERMIT SUBMITTAL 11[hj 500 West Fulton Street Sanford, Florida 32771 P. O. Box 2808 Sanford, Florida 32772-2808 Phone 407 322-684.1 Fax 407 330-0639 Engineers Surveyors Architects Planners Landscape Architects Environmental Scientists Construction Management Traffic/ Transportation Eng. C.O.A. No. 32.15 Survey L.B. No. 7143 Arch. Lic. NO. AA2600926 Landscp. Lia No. LC0000298 © 2012 m U m JZ Z� •fin pZ ecu as ZU-)-c F 0mr' � Cn � � 11 LU LL -559--0-rj�� O (D'q C C z COD Ca ID 55-Ww U 5 O 10 O N O N ik LD O W Q M •�• r . y�CEN0 r '4 ` CU -n q• 1 /'�•i� .. V` 4 •,' <ORIOP U AL ON m U m JZ Z� •fin pZ ecu as ZU-)-c F 0mr' � Cn � � 11 LU LL -559--0-rj�� O (D'q C C z COD Ca ID 55-Ww U 5 O 10 O N O N ik LD O W Q M 4. DUCT SIZES SHOWN ARE INTERNAL FREE AREA DIMENSIONS UNLESS NOTED OTHERWISE. 5. ALL SHEET METAL DUCTWORK SHALL BE EXTERNALLY OR INTERNALLY INSULATED. INSULATION IS NJT SHOWN FOR CLARITY. SEE MECHANICAL NOTES FOR INSULATION REQUIREMENTS. McDONALD'S PROJECT CODE: 009-1303 Sheet No. NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION _N N CU O QaQQ QQ z z S 0 (N CY) � O r q Ci i0 l w Q7 GI O U ` ro z -0 o a� D U Q w Q ) LL 4. DUCT SIZES SHOWN ARE INTERNAL FREE AREA DIMENSIONS UNLESS NOTED OTHERWISE. 5. ALL SHEET METAL DUCTWORK SHALL BE EXTERNALLY OR INTERNALLY INSULATED. INSULATION IS NJT SHOWN FOR CLARITY. SEE MECHANICAL NOTES FOR INSULATION REQUIREMENTS. McDONALD'S PROJECT CODE: 009-1303 Sheet No. NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION BUILDING PERMIT SUBMITTAL 3 -v O W I O C.0 O I N CD N CC � FJJ ai Q v C a> rn 4 C O V g I 0 cp 0 I N_ O N / N_ 0 N J LL LO C7 co O q - Ci 0 N LO N Q O I— O J Q C� Z W Lu Z c' Z w Z O V) ' [/n H O CL Z . ry F-- C• EXISTING 200A SERVII #2 TO PANEL AP -5. EXISTI EXISTING MAIN CIRCUI SHUNT TRIP BUTTON. CL co LP 0 N 0 N 0 �O a. BUILDING PERMIT SUBMITTAL (1) 2" CONDUI I TU D/ I CAMLKA MUM I LU UN ____________________V LIGHT POLE OR OTHER POLE, COORDINATE STUB-UPLINES WITH 1 1/2" GROMMET LOCATION WITH ACM & D/T CAMERA INSTALLER REFER TO ELECTRICAL SCHEDULE ON E0.2 FOR THIS EQUIPMENT REFER TO ELECTRICAL SCHEDULE ON EO.2 FOR THIS EQUIPMENT ON ?s . • ■ A VNEM 1/4" =1'-0" 0 2' 4' 8' 00 500 West Fulton Street Sanford, Florida 32771 P. O. Box 2808 Sanford, Florida 32772-2808 Phone 407 322-6841 Fax 407 330-0639 Engineers Surveyors Architects Planners Landscape Architects Environmental Scientists Construction Management Traffic/ Transportation Eng. C.O.A. No. 3215 Survey L.B. No. 7143 Arch. Lic. No. AA2600926 Landscp. Lic.1Vo. LCO000298 © 2012 UEY w lee v " STq�" p 'OF LL OR It S'��j' 11�i t • •..,• • �`� yah f. _NqL ENG�..��� c_.i Jz COPYRIGHT ME, LLC 06101/03 VERSION: A60 REVISED: 10/25!2011 few ®M VOLTS UN: 120 cu �LL.�`O �0�®cam; Z7�� Ia. Mw Mo U j� a L� VOLTS PH.: 208 PANEL: AP -5 REVISED EXISTING:- NO PHASE : 3 MLO("'") 1) SECTIONS: 1 O MOUNTING: SURFACE MCB 2U0 NEMA 3R 300 w on TYPE NQO SH.TRIP MFR SQ D GFP 3) ALL HEX NOTES NOT NECESSARILY USED ON ALL SHEETS. 1 L O NOTES AND REFERENCE NOTES: GENERAL NOTES: (1) ALL C.B.'S FEEDING HVAC EQUIPMENT TO BE HACR TYPE. < SERIES RATED AIC RATING ("Y- 35 KA(") 1V1FR = SIZE CB PER MFR. RECOMMENDATIONS. 0) ro W (2) ALL C.B.'S FEEDING ELEV EQUIP TO BE SHUNT -TRIP TYPE. FULLY RATED KA $ = NEW CB IN EXIST SPACE (n ❑ (3) ALL C.B.'S FEEDING ELEV EQUIP TO BE SIZED AS REQ'D BY MFR LL 2. = REPLACE EXIST CB WITH NEW PURPOSES AND ARE NOT NECESSARILY REPRESENTATIVE n_ (4) ALL C.B.'S FEEDING HID LTG TO BE HID RATED. (") NOTE: MAY REQUIRE FULL RATING TO ACHIEVE SH = SHUNT TRIP C.B. (5) NO MULTIWIRE BRANCH CKTS ARE ALLOWED AF = ARC FAULT CB (6) NOT USED. RELOCATE/REWORK EXISTING ELECTRICAL AS REQUIRED TO FACILITATE 0 0 Hft = UTILIZE EXISTING SPARE SEX NOTES - OPTIONAL CALC NO LL� 1� TOTAL AMPS A PH 147 ( ) NOTE: SIZE SHOWN 13 MINIMUM ACCEPTABLE MLO ACTUAL CONN LOAD 55 KVA 152 AMPS AMPERAGE. INCREASE SIZE IF REQUIRED TO ACHIEVE DEMAND 37 KVA 104 AMPS TOTAL AMPS B PH 156 1/2"C-2#12, 1#12 GND & 1#12 ISOLATED GROUND TO 20A, 1P CIRCUIT QUANTITY OF POLES OR BREAKER SIZEIAIC RATING AS DIVERSITY 37 KVA 104 AMPS TOTAL AMPS C PH 153 CALLED FOR IN SCHEDULE. 8) LOCATIONS FOR DISCONNECT SWITCHES SHOWN ON DRAWINGS IS FOR ERROR CODE AR TRANSFORMER SIZE KVA GENERAL INFORMATION ONLY. �3 TAMPER RESISTANT GFCI DUPLEX RECEPTACLE MOUNTED AT 18" AFF IN WIDTH: 20 DEPTH: 6.00 SECTION 1 WITH MAINS PUBLIC AREAS (UNLESS OTHERWISE NOTED), EC SHALL PROVIDE PASS & WITHIN SIX (6) FEET OF EQUIPMENT AS REQUIRED BY APPLICABLE LOAD C.B. C.B. REF AMPS POLE NOTE i LOAD CKT. CKT. REF C.B. LAMPS.B. NO. NO. NOTE POLE AMPS AMPS AMPS DESCRIPTION CONN TYPE DESCRIPTION CONN TYPE AMPS AMPS AMPS FRYER 39 7.0 39 60 3 SH 1 2 SH 3 60 39 FRYER 39 7.0 _ 39 7.0 39 -- -- 3 4 -- 39 -- 39 7.0 -_ 39 7.0 39 -- - 5 6 -- -- 39 -- 39 7.0 SHUNT TRIP SPACE 04 1 7 8 1 SHUNT TRIP SPACE AU FRYER 39 _ 7.0 39 60 3 SH 9 10 SH 1 20 13 FRYER INTERLOCK 13 7.0 _ 39 7.0 39 -- 11 12 1 SHUNT TRIP SPACE _ 39 7.0 39 -- --- 13 14 SH 1 20 4 REFRIGERATOR 27" WIDE 4 7.0 SHUNT TRIP SPACE 1 15 16 1 SHUNT TRIP SPACE REFRIGERATOR WORKTABLE -48•' 5 7.0 5 20 1 17 18 SH 1 __20 12 FRYER CONTROLSIFILTER PUMP 12 7.0 ICE MAKER 12 5.0 12 20 3 19 20 1 SHUNT TRIP SPACE -- 12 5.0 12 -- - 21 22 1 20 10 WALL MTD FREEZER 10 7.0 _ 12 5.0 12 -- 23 24 3 20 SPARE 0.2 SSBB 5 5 20^ 1 25 '26 -- - - 0.2 SSBB 5 5 20 1 27 28 -- -- - 0.2 COD 41 OPTICAL ISOLATOR 2 2 M5.0 20 1 0 29 COD U2 OPTICAL ISOLATOR 2 2 20 1 t" 31 32 N 1 20 7 WI -FI RECPTS 5 3.0 SPARE 20 1 SPARE 0.2 20 1 _33 35 36 1 20 SPARE 0.2 SPACE 1 37 38 MFR 3 30 TVs 18.0 SPACE _ 1 39 40 --- -- - 18.0 SPACE 1 41 42 -- -- - 18.0 SUBFEED LUGS/BREAKER SUBFEED LUGS/BREAKER S.F. S.F. _ - -. - -- S.F. S.F. - S.F. S.F. - - - ON ?s . • ■ A VNEM 1/4" =1'-0" 0 2' 4' 8' 00 500 West Fulton Street Sanford, Florida 32771 P. O. Box 2808 Sanford, Florida 32772-2808 Phone 407 322-6841 Fax 407 330-0639 Engineers Surveyors Architects Planners Landscape Architects Environmental Scientists Construction Management Traffic/ Transportation Eng. C.O.A. No. 3215 Survey L.B. No. 7143 Arch. Lic. No. AA2600926 Landscp. Lic.1Vo. LCO000298 © 2012 UEY w lee v " STq�" p 'OF LL OR It S'��j' 11�i t • •..,• • �`� yah f. _NqL ENG�..��� c_.i Jz m Z >^ few ®M Lu cu �LL.�`O �0�®cam; Z7�� Ia. Mw Mo U j� a L� 0.6 0 0 CV a CV m 0 w a. 1■ z O O O U 0 0 Iy_ V) w F- m z r1r MEME00EN NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION O N p7 J w J w m I L� 1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE. wLL O 2) REFER TO SPECIFICATIONS. 300 w on z 0 < _j U) 3) ALL HEX NOTES NOT NECESSARILY USED ON ALL SHEETS. 1 L O L (D (3l N 3 0) w �j O0 CL 0) ro W Z 0 q o Q) ❑ ❑ U Q (n ❑ -7 LL NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION GENERAL NOTES 1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE. wLL 2) REFER TO SPECIFICATIONS. 300 w on z 0 < _j U) 3) ALL HEX NOTES NOT NECESSARILY USED ON ALL SHEETS. 1 L 4) EXISTING CONDUIT ROUTING IS UNKNOWN. z LLII =) 5) WHERE CONDUIT ROUTING IS SHOWN, THE CONDUITS ARE SHOWN FOR T > 0 DIAGRAMMATIC PURPOSES AND ARE NOT NECESSARILY REPRESENTATIVE n_ Z � OF EXACT PLACEMENT. U 6) RELOCATE/REWORK EXISTING ELECTRICAL AS REQUIRED TO FACILITATE 0 0 LU Z SEX NOTES RENOVATION. LL� 1� NEW HAND DRYER, INTERCEPT, CONNECT AND EXTEND TO EXISTING HAND DRYER CIRCUIT MADE SPARE BY DEMOLITION. 7) CONTRACTOR SHALL MAINTAIN CONTINUITY TO EXISTING FIXTURES LL AND/OR DEVICES REMAINING. Q 1/2"C-2#12, 1#12 GND & 1#12 ISOLATED GROUND TO 20A, 1P CIRCUIT BREAKER IN EXISTING SPACE OF PANEL AP -5 FOR NEW SEEQ MENU 8) LOCATIONS FOR DISCONNECT SWITCHES SHOWN ON DRAWINGS IS FOR AR GENERAL INFORMATION ONLY. �3 TAMPER RESISTANT GFCI DUPLEX RECEPTACLE MOUNTED AT 18" AFF IN 9) MOUNT ALL DISCONNECT SWITCHES FOR MECHANICAL EQUIPMENT PUBLIC AREAS (UNLESS OTHERWISE NOTED), EC SHALL PROVIDE PASS & WITHIN SIX (6) FEET OF EQUIPMENT AS REQUIRED BY APPLICABLE SEYMOUR "SAFELOCK" 2095 -TR-* ("*": 1=IVORY, W=WHITE, GRY=GRAY, CODES AND STANDARDS. Sheet N0. BK=BLACK, RED=RED, LA=LIGHT ALMOND). SPECIFIED RECEPTACLE BECOMES DE -ENERGIZED UPON FAILURE OF GFCI DEVICE. NO SUBSTITUTIONS. (TYPICAL). COORDINATE COLOR WITH ARCHITECT AND INTERIOR DESIGN. R U 04 CONNECT TO EXISTING 20A, 1P C.B. IN EXISTING AP -5 McDONALD'S PROJECT AU CODE: 009-1303 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION BUILDING PERMIT SUBMITTAL I VV 1 I_,. I I IL VVI \LL V1 11 11_VL I U \1 - -1 1 I 1 I/ - VI 1/ 1 -- --- . v . - c� z 0 CI C r- Iq T co N O N 4- Q CD U Q, 3t ci lil o� O N_ O N d ti q U P, -o n 0 0 U a co 0 N O i a 'r n (D z w w Q z V) 0 R 011-1 - irm LP I II II 11 11 II II II I� LIGHTING LOAD CALCULATIONS: EXISTING DINING AREA LIGHTING SHALL BE REMOVED: (29) COMPACT FLUORSCENT FIXTURES - 1508 WATTS (2) PENDANT LIGHTS - 150 WATTS (2) WALL SCONCES - 52 WAITS SUBTOTAL - 1710 WATTS NEW DINING AREA LIGHTING = MOUNTING LOCATION (44) 12.5 WATT LED LIGHTS + 550.0 WATTS (2) 11 WATT ACCENT LIGHTS + 22.0 WATTS (3) 22 WATT ACCENT LIGHTS + 66.0 WAT IS (7) 18 WATT PENDANT LIGHTS + 126.0 WATTS (2) 18 WATT WALL SCONCES + 36.0 WAITS TOTAL NEW LOAD ON EXISTING (1) 2UA, 1P C.B. (LP:2) SUBTOTAL + 800.0 WATTS CEILING SUBTOTAL REMOVED LOAD - 910.0 WATTS EXISTING RESTROOM LIGHTING ON (1) 20A, 1P C.B. (LP:13) TO BE REMOVED: (6) 2x4 FLUORSCENT FIXTURES - 690 WATTS (1) 1x4 FLUORSCENT FIXTURES - 75 WATTS (2) COMPACT FLUORESCENT DOWN LIGHTS - 84 WATTS Q SUBTOTAL - 849 WATTS NEW RESTROOM LIGHTING = (14) LED 12.5 WATT LIGHT FIXTURES + 175.0 WATTS 12.5W LED TOTAL NEW LOAD ON EXISTING (1) 2UA, 1P C.B. (LP:13) SUBTOTAL + 175.0 WATTS DINING SECURITY LIGHTING: SUBTOTAL REMOVED LOAD - 674.0 WATTS 1) DIFFERENCE IN TOTAL LOAD INTERIOR LIGHTING (FURNISHED BY INTERIOR DESIGNER) - 1584.0 WATTS EXISTING EXTERIOR SOFFIT LIGHTING ON (2) 20A, 1P C.B.(S) (LP:16 & 18) TO BE REMOVED: — (8) 10OW METAL HALIDES - 904 WATTS NEW EXTERIOR LIGHTING (13) LED 30 WATT LIGHT FIXTURES + 390 WATTS TOTAL NEW LOAD ON EXISTING (1) 20A, 1P C.B. (LP:16) + 390 WATTS SUBTOTAL REMOVED LOAD - 514.0 WATTS 2) DIFFERENCE IN TOTAL LOAD EXTERIOR LIGHTING B1 - 514.0 WATTS TOTAL LOAD CHANGE THIS SHEET DUE TO LIGHTING RENOVATION 1) + 2) _ N /A - 2098.0 WATTS FLOOR PLAN 1/410 =1f -Ott - LIGHTING LIGHTING FIXTURE SCHEDULE: LAMPS MANUFACTURER AND MARK SYMBOL DESCRIPTION DIFFUSER BALLAST MOUNTING LOCATION WATTS TYPE CATAI-OG NUMBER A O LED DOWNLIGHT N/A 12.5W LED CEILING DINING SECURITY LIGHTING: SLS-612W-GU24-SLS6C-1000 - WHITE TRIM B Q LED DOWNLIGHT N/A 12.5W LED CEILING DINING SECURITY LIGHTING: (FURNISHED BY INTERIOR DESIGNER) #SLS-612W-GU24-SLS6C-1000416WH B1 O LED DOWNLIGHT N /A 12.5W LED CEILING DINING SECURITY LIGHTING: #SLS-612W-GU24-SLS6C-1000-LT6BB-(BLACK TRIM) D SQUARE SINGLE RECESSED LED N/A 1-11W LED - RECESSED DINING SECURITY LIGHTING # LIGHT MLLPARI-TFLO1-B24-LRP-38 D1 Q RECTANGULAR DOUBLE RECESSED N/A 2-11W LED _ RECESSED DINING SECURITY LIGHTING # O LED LIGHT MLLPAR2-TFL02-824-LRP-38 E GREEN SHADE 18W O CFL SECURITY LIGHTING # DECORATIVE PENDANT PENDANT DINING MDP-GN-231CFL-BS F20 EXIT SIGN WITH BATTERY _ 1.8 LED - SURFACE DINING SECURITY LIGHTING: BACKUP 800-544-4848 S1 "DOWN ONLY" RADIAL WALL TEMPERED GLASS 1-30W LED EXTERIOR EXTERIOR SECURITY LIGHTING: RWSC-30LED-WD-PS-120 Q SCONCE WALL WALL ORDER THESE NEW FIXTURES EARLY BECAUSE OF LONGER LEAD TIMES. WS1 DECORATIVE WALL SCONCE TEMPERED GLASS 18W INTERIOR INTERIOR WALL SECURITY LIGHTING: DWSM-18CU24-WH Q LED WALL KEY DENOTES LIGHTING FIXTURES SHOWN SHADED SHALL BE FIXTURE TYPE AWIRED TO A DEDICATED EMERGENCY CIRCUIT AND BE PROVIDED BATTERY EMERGENCY 41 WITH A TYPE DENOTES CIRCUIT BALLAST, NUMBER BUILDING PERMIT SUBMITTAL 1. EC SHALL CONNECT ALL EXIT SIGNS, EMERGENCY LIGHTS AND NIGHT LIGHTS TO EXISTING LOCAL AREA LIGHTING DEDICATED EMERGENCY CIRCUIT AND PROVIDE LOCKABLE BREAKER. EC SHALL VERIFY ALL REQUIREMENTS AND FINAL EMERGENCY LIGHTING LOCATIONS WITH LOCAL AUTHORITIES. INCLUDE ALL COSTS IN BASE BID. 2. IF NOT INSTALLED BY MANUFACTURER, EC SHALL BE RESPONSIBLE FOR THE COMPLETE INSTALLATION OF THE EMERGENCY INVERTER BALLAST IN NIGHT LIGHTING FIXTURES SHOWN ON THIS SHEET. 3. ALL FIXTURES DENOTED AS NIGHT LIGHTING FIXTURES SHALL BE CONNECTED TO A BATTERY INVERTER AS SHOWN: INVERTER IS SECURITY LIGHTING LG1 SERIES RECESSED T -GRID. BALLAST BATTERY SHALL MAINTAIN 87.5% OF THE NOMINAL BATTERY VOLTAGE AFTER 1.5 HOURS TO COMPLY WITH NEC SECTION 700 AND UL924, 500 West Fulton Street Sanford, Florida 32771 P. 0. Box 2808 Sanford, Florida 32772-2808 Phone 407 322-6M Fax 407 330-0639 Engineers Surveyors Architects .Planners Landscape Architects Environmental Scientists Construction Management Traffic/ Transportation Eng. C.O.A. No. 3215 Survey L.B. No. 7.143 Arch. Lic. No. AA2600926 Landscp. Lia No. LCOOM98 Q 2012 En 0 w LL m z 0 Q qZ R 0 0 0 0 v M V) H > N 4 °' N � 0 QQQQ441 z 4. EMERGENCY LIGHTING HAS BEEN DESIGNED PER NFPA 101 TO MAINTAIN 1 J J FC IN PATH OF EGRESS. IF FIELD CONDITIONS REQUIRE ANY CHANGES TO w w `D co LIGHTING DESIGN, EMERGENCY LIGHTING, SHALL BE INSTALLED TO MEET -'if if N THE ABOVE REQUIREMENTS. o D ci U GENERAL NOTES a C: s1 U z 1) REFER TO GENERAL NOTES FOR THIS DISCIPLINE. o D —i 2) REFER TO SPECIFICATIONS. Q U) LL 3) ALL HEX NOTES NOT NECESSARILY USED ON ALL SHEETS. 4) EXISTING CONDUIT ROUTING IS UNKNOWN. 5) WHERE CONDUIT ROUTING IS SHOWN, THE CONDUITS ARE SHOWN FOR DIAGRAMMATIC PURPOSES AND ARE NOT NECESSARILY REPRESENTATIVE OF EXACT PLACEMENT. 0 6) RELOCATE/REWORK EXISTING ELECTRICAL AS REQUIRED TO FACILITATELL LL Cq RENOVATION. � � � 7) CONTRACTOR SHALL MAINTAIN CONTINUITY TO EXISTING FIXTURES w L AND/OR DEVICES REMAINING. < Z z HEX NOTES 0 :r < 0 O NEW LIGHTS TO BE CONNECTED TO EXISTING EXTERIOR LIGHTING �' t J _j CIRCUITS MADE SPARE BY DEMOTION. ws0Ij zz 0 NEW LIGHTS TO BE CONNECTED TO EXISTING LOCAL AREA LIGHTING LL DEDICATED EMERGENCY/NIGHT LIGHT CIRCUIT 20A, 1P CIRCUIT ® C4 w BREAKER, REFER TO LIGHTING GENERAL NOTE #1 THIS SHEET. _j U3 NEW LIGHTS TO BE CONNECTED TO EXISTING RESTROOM LIGHTING 20A, 1P CIRCUIT BREAKER MADE SPARE BY RENOVATION. 4� RELOCATED COMBINATION EXIT SIGN/2-HEAD EMERGENCY LIGHT, CONNECT TO EXISTING CIRCUIT FROM PREVIOUS LOCATION. �5 NEW LIGHTS TO BE CONNECTED TO EXISTING. DINING AREA LIGHTING Sheet No. 20A, 1P CIRCUIT BREAKER MADE SPARE BY RENOVATION. 1 McDONALD'S PROJECT CODE: 009-1303 NOTE: THE SCALE OF THESE PLANS MAY HAVE CHANGED DUE TO REPRODUCTION McDon Id's reFres�h, 1] 2 French Ave Sanford, FL CONTACTS: Owner / Operator: Mcopco Mark Bonczyk phone: 407.432.0316 email: Mark. Bonczyk4us. mcd.com or Jackie Bunting phone: 636.578.3412 email: Jackie.Bunting@us.mcd.com Area Construction Manager (ACM): Tim Chess cell: 772.486.4190 email: tim.chess4us.mcd.com Designer: Carrie Leigh Designs Carrie Bollella email: Carrie@carrielei cell: 561.929.7540 ghdesign.com Seating & Decor Supplier: J.B.I. Erika Carlson email: ecarlson@jbi-interiors.com 310.667.5608 CONTACTS CONT'D: Graphics: American Screen Art Ann Bowen phone: 800. 251. 9031 ext. 7337 email: abowen@americanscreenart.com or GFX Rick Formanski phone: 847. 543. 4681 email: rformanski@gfxi.com Lighting: Security Lighting Steve Friedman phone: 847. 279. 0627 email: stevef@securitylighting.com D 1 April 10, 2011 DRAWING INDEX: ID 1 Proposed reFRESH Updates ID 2 Recommended List reFRESH items ID 3 Demo Floor plan ID 4 Wall Finish Plan ID 5 Restroom finish Plan ID 6 Graphic Wall Plan ID 7 Floor Plan ID 8 Floor Finish Plan ID 9 Ceiling Plan ID 10 Before & After Photo ID 1 1 Graphic Detail - Qua ID 12 Graphic Deta ID 13 Graphic Deta ID 14 Graphic Deta ID 15 Graphic Deta ID 16 Graphic Deta ID 17 Graphic Deta ID 18 Site Photos ID 19 Site Photos L� -side dining view 1 lity 2 - FV -1 6 lity 2 - FV -1 8 lity 2 - FV -1 2 lity 2 - FV -1 0 lity 2 - FV -1 9 lity 2 - FV -21 lity 2 - FV -20 S= i � S £ s 9 ffsf Y ail, }}$}$ S kLK 7£: x A u Sx _..S.a.f.✓+s`Y Eiy ..�.aei......a ... ...... .........%..'..:rx::.... i � b. � .i s : A if y �"".� x 'i�`, i� h� � � N�',.�: � f s3� z.uV•S- t �+, a+1...E f ML,.` � � ii : H .?eE, :o.A ., f�.n`- 2� .c<ctt % ?'. ..,.. �+ McDonald's reFresh 112 French Avk/.-'N',.l Sanford, FL FINAL RECOMMENDATIONS - LTRS reFRESH INTERIOR UPDATES SCOPE LIST: 1.Remove artwork & artifacts & replace with graphics where specified 2.Replace 2x4s'in restrooms with recessed lights 3.Replace pendants with new pendants 4.Replace wall sconces 5. SEEQ - Update menu board , 6. SEAQ - Add side wall menu board or side interrupt panel 7. SEEQ - Add center island screening & new beverage bar wall tile 8. SEEQ - Unbrand center island & beverage bar equipment 9. SEEQ - Replace service counter or Replace tile on service counter front seating10. Add new 11. Add a soffit over service counter & beverage bar 12. Replace chairs throughout 13. Replace booth upholstery throughout OR replace booths 14. Remove decorative columns throughout & soffit for columns in front dining 15. Remove shutters throughout 16. Replace specified table tops 17. Add accent floor tile in front of service counter SCOPE LIST CONTINUED: 19. Replace ALL finishes in restrooms 20. Replace wall covering 21. Remove crown molding 22. Replace damaged ceiling tile 23. Replace corian low wall caps 24. Remove corner guards from all walls Store ID: 1 0/0-00 MCC9' ei, April 10, �201 1 -� ......... s r.: on: z. 3. ze z aa9 01 �: 'r f i _-s3 Yv, ft, #,::.,�'X,? r j '....:�d r..x' :.n•.....i .....,+ Y ..ter" ai... k t,I .... ,;, j: 3 .. j McDon Id I s reFresh 1] 2 French Ave Sanford., FL ril 10 1 --ma m R e q u Mr e-, d, 0D 0 0 I.R(E;Nrove artwork & artifacts & replace with graphics where specified I I . . ....... . 2 s in restrooms with recessed lights -,place pica7ndants w'th new pendants r,,*oncec .R e--� p I a e_-.- w a 5,� EQ- Update menu board 'de interrupt panel Add s'da:::A wall menu board or S)I I NJ U.- I t�_ A 0 /. `D,'�'])) - A 'd ��-z�-,Y­en'ng & new beverage bar wall tile r--% 4 - - I k� n . -\ , - lan P -A bar �"'menT Un I i -A , ! I k -A --,, i�j K� v e r a g e Pd(_-Acefleon svocc:-, ou,-) , %kJ i I ice counte, 9. LE, Q - P I a e s e M d* _4"o evpionde, �ning area. i U A a n e w 0 io I's co ot over s sII ervict7 un'er & beverage bar 2. Remove decora-1-0 rive columns throug'--iout & soffit for columns in front IT n 3.v, Remove shutters 'Throughout Replace chairs throughout 2. ReplarC.,,e booth ur,_)hoIst1,:_--.ar\,/ the u ll ace booths Store IID: 11 ID 2 W7`0iRi7�7iTC7i! April 10, 2011 Highly Recommended Confinuede 0 ur�_ Aa, 3. Replace spec'fied table, tops I I -4. Add accent floor the in front of -service count� 18. Replace trash receptacles 0 19. Replace ALL finishes in restrooms 0 20. Replace wall covering 0 21. Remove crown molding 0 22. Replace damaged ceiling the 0 23. Replace corian low wall caps 0 24. Remove corner guards from all walls go.......... Rll X. Secondary Recommend aTIo ,::: ... ................. 1. Repaint door f ms n reszirooms (If Hid:: hly recommendedis not don i , ii M w�3 f M WON ..:.:.:...:... c � E a: 01 si taA McDonald's 1 1 2 French Ave Sanford.. Fl. �i 11 ii 11 .11 ii 11 11 L= DEMC 11-11-011 F = Tr I II II II II IN III IIII Store ID: 13864 0/0: McOpCo April 10, 201 1 r: es.,; a I . ... ns fl.ftA A-1 ff '16 r: es.,; a I . ... ns fl.ftA WALL FINISH LEGEND: WC -1 = MAIN WALL COVERING MANUFACURER: MDC MODEL: FIDDLEBACK, BBFB10/4546 COLOR: SWANEE RIVER CONTACT: 800.621.4006 TL -4 = WALL TILE **(TO MATCH EXISTING) MANUFACURER: DAL -TILE SERIES: CONTINENTAL_ SLATE, COLOR: CS53 ASIAN BLACK SIZE: 12"x12", GROUT: TO MATCH EXISTING CONTACT: HILLARY FRANK 847.997.1893 LOCATION: WAINSCOTING FOR NEW WALLS, VERIFY THAT TILE MATCHES EXISTING WAINSCOTING TL -5 = COVE BASE TILE MANUFACURER: DAL -TILE SERIES: TERRA ANTICA, COLOR: TA01 ORO SIZE: V.I.F. - TO MATCH HEIGHT OF EXISTING BASE TILE CONTACT: HILLARY FRANK 847.997.1893 LOCATION: WALL BASE FOR NEW WALLS TL -9 = SEEQ - CENTER ISLAND SCREEN & BEV BAR REAR WALL TILE_ MANUFACURER: EUROWEST, SERIES: FEEL COLOR: BLACK TASTE_, SIZE: 10" x 30" GROUT: LATRICRETE #22, MIDNIGHT BLACK GROUT JOINT TO BE AS TIGHT AS POSSIBLE_, 1/16" MAXIMUM, CONTACT: JAN DETER 714.309.9551 TI_ -10 = SEEQ - BEVERAGE BAR SIDE WALL TILE MANUFACURER: EUROWEST, SERIES: MA.DE COLOR: UNI GRIGIO, GROUT: LATICRF_TE, 18 SAUTERNE CONTACT: JAN DETER 714.309.9551 P-2 = PAINT MANUFACURER: SHE_RWIN WILLIAMS COLOR: SW 6717 LIME RICKEY LOCATION: SOFFIT OVER SERVICE COUNTER & BEV. BAR PL -4 = LAMINATE FOR SIDE MENU BOARD WALL MANUFACURER: WILSONART FINISH: 1573-60 FROSTY WHITE (MATTE) CONTACT: KATHY WALKER 630.487.1642 PL -5 = LAMINATE (TO MATCH EXISTING) MANUFACURER: FORMICA COLOR: 5164-45 PUNCHED STAINLESS LOCATION: ALL NEW CHAIR RAILS SS -2 = SOLI -ID SURFACING FOR SILLS & LOW WALL CAPS MANUFACTURER: CORIAN, COLOR: NIGHT SKY CONTACT: 800.426.7426 SS -3 = SEEQ - SOLID SURFACING FOR SERVICE COUNTER MANUFACTURER: CORIAN, COLOR: LINEN CONTACT: 800.42 6.742 6 BF -1 = BASF_ FINISH FOR SIDE MENU BOARD WALL CHEMETAL 927, LIGHT STAINLESS STEEL 0400 4" BASE: CHEMETAL 927 LIGHT STAINLESS STEEL WITH 1/4" CORNER GUARDS, BRUSHED STAINLESS STEEL. APP: APPLIED BY SEATING & DECOR PRE INSTALL. M-1= NEW SEEQ MENU BOARD/ GRAPHICS M-2 = NEW SIDE MENU. MOUNTING HEIGHT TO BE 36'' AFF. SEATING & DECOR COMPANY TO VERIFY PLACEMENT MANUFACTURING & COORDINATION OF MENU COMPONENTS. WALL LEGEND W W d £u X10 = WC -1, wall covering for new walls = PL -5, Laminate chair rail (to match existing) = TL -4, wall tile (to match existing) = TL -5, tile base (to match existing) _ £ = WC -1, wall covering for existing walls = Existing wainscoting = Graphic wall covering for new walls = PL -5, Laminate chair rail (to match existing) = TL -4, wall the (to match existing) = TI_ -5, the base (to match existing) = Graphic wall covering for existing walls = Existing wainscoting = Graphics on louvered partition wall = SS -2, Low wall top cap = TL -4, wall the (to match existing) = TL -5, tile base (to match existing) = SS -2, Low wall top cap (See ID -17 for details) = TL -7, wall tile = TL -8, tile base ,3 = 33-2, Window sill to match existing corian sills = TL -4, wall the (to match existing) = TL -5, tile base (to match existing) = TL -9, wall tile for center island screening wall & beverage bar back wall = SS -3, Coria n for service counter - SEEQ = TL -7, Accent base tile. -= PL -4, New laminate for SEEQ side wall menu board. = M-2, New side menu board = BF -1, New base finish for SEEQ side wall m r = TI_=10, wall file for beverage bar side walls = TL -5, tile base [j] = M-1, New updated SEEQ menu board 0 z 0 V) z Q 0 z V) X w :. ..0 �J T T f �? Q !..................... .................. WI L .. T-1 VA Rf-..t............ _......-. ..........__.,.j TYPICAL NEW DINING WA McDonald's reFresh 1 1 2 French Ave Sanford, FL WC -1, OR GRAPHIC WALL COVERING P L-5 TL -4 TL -5 LL LAYOUT L_. f� 3 s9 SEE ID -5 FOR RESTROOM FINISHES L UQUO t� L.. e SEE ID -5 FOR f RESTROOM FINISHES J x. s s s -� :a "_ 1 F14 a 0 II II II II II II II WC -1 TL -9 TI_ -10 TL -5, 6 - See ID -8 SS -3 TL -7, 8 - See ID -8 11'-3' Fir= ===ir IF _IIJII - IL -------- JL_ II II II -- ' F __1 f 40 .:� �• f: 11-11-011 1/8 - SS -2 P L-5 Store ID: 13864 0/0: MCOPCO April 10, 2011 P-2 I w: 3 f: z ,z � i a R tl C h RESTROOM FINISH LEGEND: *THESE FINISHES ARE HIGHLY RECOMMENDED - TO BE DONE AS A COMPLETE PACKAGE *SEF 111 LEGEND FOR SECONDARY RECOMMENDATIONS TL -1 = MAIN WALL TILE MANUFACURER: EUROWEST MODEL: MA. DE SIZE: 12 11 x24 11 2"x24" COLOR: UNI BIANCO GROUT: LATICRETE_, COLOR: 18 SAUTERNE CONTACT: JAN DETER 714.309.9551 TL -2 = ACCENT TILE MANUFACURER: EUROWEST MODEL: BRUSHSTROKE SIZE: 6"x24" COLOR: WALNUT STROKE GROUT: LATICRETE, COLOR: 35 MOCHA CONTACT: JAN DETER 714.309.9551 LOCATION: SIDES & BELOW THE SINKS TL -3 = GLASS ACCENT TILE MANUFACURER: STONE SOURCE MODEL: GLACIER TILE SIZE: 2" x 2" COLOR: C05 EVERGREEN GROUT: LATICRETE, COLOR: 18 SAUTERNE CONTACT: 866.271.8722 LOCATION: ABOVE THE SINK SS -1 =SOLID SURFACING MANUFACURER: CORIAN COLOR: ANTARCTICA CONTACT: 800.426.7426 LOCATION: VANITY FINISH &HAND DRYER BACKER P-1= PAINT MANUFACURER: BENJAMIN MOORE COLOR: OC -28 COLI-INGWOOD LOCATION: RESTROOM STALL DOOR FRAMES PL -1 = PLASTIC LAMINATE MANUFACURER: WILSONART COLOR: 4830K-18 SATIN STAINLESS W/ AEON CONTACT: KATHY WALKER 630.487.1642 LOCATION: RESTROOM STALL DOORS PL -2 = PLASTIC LAMINATE MANUFACURER: WILSONART COLOR: 7054-60 WILD CHERRY CONTACT: 800.433.3222 LOCATION: RESTROOM ENTRANCE DOORS SINK MANUFACURER: TOTO MODEL: LT540G UNDER COUNTER LAVATORY COLOR: COTTON CONTACT: HD SUPPLY, LEE FLASHER 407.509.7626 FAUCET MANUFACURER: TOTO MODEL: TEL3GS10#CP CONTACT: HD SUPPLY, LEE_ FLASHER 407.509.7626 RESTROOM FINISH LEGEND *THESE FINISHES ARE SECONDARY RECOMMENDATIONS - TO BE DONE IF HIGHLY RECOMMENDED ITEMS ARE NOT DONE P-3= PAINT MANUFACURER: GC CHOICE COLOR: BLACK, SEMI GLOSS ENAMEL LOCATION: REPAINT DOOR FRAMES *PROFESSIONALLY CLEAN EXISTING TILE P L-2 ........... . . ... . McDonald's reFtesh . .................. ....... .. ..... ............ .............. ......... .. . . . . . . . .. . ........... XM::::::X:: 1 1 2 French Ave .. .. ....... ... ............. Sanford, FL ............ WALL LEGEND f n u f a m = TL -1, Main wall the 9 M M 111 $11.� = TL -2, Accent wall the = TL -3, Glass wall the above sink = TL -2, Accent wall tile below sink m-r.m = PL -1, Laminate for restroom stall doors = PL -2, Paint for restroom entrance doors SEE FINISH LEGEND FOR SPECIFICATIONS P-1 PL -1 TL -1 TL -3 TL -2 SS -1 aj A�* d DY&TAI T. M: I I N I L4 E !I Will IL 6, 1/4 11=1 1-0'I CORM. VANITY TOP WITH TURNW-DOWN EDO S ASS SHOWN F'F;OORMXDI PRO SFT" I.AVArORY SUPPOR-1 by JAY R; SMITH MH CQ - ,OR EQ0AL M VH C()NC.ff fXD ARMS AHD E5CUTC.11FG N PU%TP PA�TJIQN AS INDICATE -0 ON FLOOR PLAN . -.- – [Q) 11 ABX Pi.y"Y0t,J`.C7 SauVVR14rC VERITY WITH CO!JNTFR TOP MA1`lWAC URF.R, PIPING PROfECIION OVER PIPES SEE PF.0.JMMN.0 FLOATING VANITY SECTION Store ID: 1386:1F 0/0: mcopco April 10, 2011 : 2 f x z^ f(. r� M M' ' r .: :: ......:.. :..... ....,�� rf�j{ .. I a r 3 ... .e C p '. Y 1^.' " .v i'i� ..441 •'� �. i `A..y.o.:.�3i.,t;:f� '..y15 .. 323y,z,'ist .., .s.11 L II II II II II �I �� a i� II II II II II II II II II==JL= =JL= McDonald's reFresh 1 1 2 French Ave Sanford, FL / See ID -15 for sizes & additional notes II II II II II II II II 1/8 If= 1 1-011 Store ID: 13864 0/0: MCOPCO April 10, 2011 or sizes al notes See ID -1 5 for sizes & additional notes � s ��fki� E£ 1p� khjy e ..�.. .K ro...uid tl S..cA' FURNITURE LEGEND: T B-1 = EXISTING TABLE TO BE RE -USED IF UNDMAGF_D 'VIF TABLE_ TOP IS DAMAGED, REPLACE WITH NEW TABLE SIZE_: EXISTING SURFACE: PL -2 EDGE: BLACK TB -2 = NEW TABLE (OR EXISTING TABLE TO BE RE -USED IF UNDMAGED) SIZE: 421 x 30"W SURFACE: PL -2 EDGE: BLACK TB -3 = NEW TABLE (TO BE ADA COMPLIANT) SIZE: 42" I_ x 30" W SURFACE: PL -2 EDGE: BLACK THBI ,4 - NEW TABLE SIZE: 42" L x 24" W SURFACE: PL -3 EDGE_: BLACK TB -S = EXISTING TABLE TOP - TO BE REPLACED SIZE_: SAME AS EXISTING SURFACE: PL -3 EDGE: BLACK B-1 = NEW BOOTH - TO CLOSELY MATCH EXISTING BOOTHS SIZE: APPROX. 8 ' L V.I.F. UPHOLSTERY: UP -1 CII I = 1951 CHAIR (FREE STANDING) COLOR: GREEN r-." I-2 = 1951 CHAIR (FREESTANDING) COLOR: GREY '.R-1 = TRASH RECEPTACLE USE APPROVED TRASH RECEPTACLE HORIZONTAL SURFACE: SS -2, VERTICAL SURFACE: PL -2 VINYL BUMPER EDGE: BLACK ID W. = VINYL UPHOLSTERY MANUFACURF_R: DESIGN TEX SERIES: ARGIANO COLOR: 3411-802 IRON ORF_ CONTACT: 800.221.1540 LOCATION: TO REPLACE UPHOLSTERY ON ALL EXISTING BOOTH BACKS & SEATS PI�...m2 = PLASTIC LAMINATE_ MANUFACURF_R: WILSONART COLOR: 7054-60 WILD CHERRY CONTACT: 800.433.3222 LOCATION: SPECIFIED TABLE TOPS PL -3 = PLASTIC LAMINATE MANUFACURE_R: WII_SONART COLOR: 7949K-07 ASIAN NIGHT CONTACT: 800.433.3222 LOCATION: SPECIFIED TABLE TOPS SS -2 = SOLID SURFACING MANUFACTURER: CORIAN COLOR: NIGHT SKY CONTACT: 800.426.7426 "NOTE: REPLACE ANY DAMGAGED EXISTING TABLE TOPS I D-(E) I C;, . co u21> TBL- w ` TBL-5 F TBL-5 F A -A LIN 2 POW��/. 11'-3° T )L-4 E�v 1 1/8--------- CH-1 CH -2 UP-] P L-2 PL -3 Store ID: 13864 0/0: mcopco April 1 0, 2011 UP- SS -2 0 P uF"- ID 7 ,y6 zgff } }fi 5 i4 K -, r`z :, fiLmm: F� r f ryy �• -'.<i 3 .,.. �,'. abs R y� � � R. �z ¢ < I 3 y 3 .. £ �. -r fi R tF niu.� '+.m?''. .jr .:F .. J. FLOORING LEGEND: TL -4 = WALL TILE **(TO MATCH EXISTING) MANUFACURER: DAL -TILE SERIFS: CONTINENTAL_ SLATE_, COLOR: CS53 ASIAN BLACK SIZE: 12"x12', GROUT: TO MATCH EXISTING CONTACT: HILLARY FRANK 847.997.1893 LOCATION: WAINSCOTING FOR NEW WALLS, VERIFY THAT TILE_ MATCHES EXISTING WAINSCOTING TL -5 = COVE BASE TILE (TO MATCH EXISTING) MANUFACURER: DAL -TILE SERIES: TERRA ANTICA COLOR: TA01 ORO SIZE: V.I.F. - TO MATCH HEIGHT OF EXISTING BASE TILE GROUT: MAPEI, COLOR: 05 CHAMOIS CONTACT: HILLARY FRANK 847.997.1893 LOCATION: WALL BASE FOR NEW WALLS TL -6 = FLOOR TILE (TO MATCH EXISTING) MANUFACURER: EUROWEST SERIES: TERRA ANTICA COLOR: TA01 ORO SIZE: 12 11 2" x 12" GROUT: MAPEI, COLOR: 05 CHAMOIS CONTACT: JAN DETER 714.309.9551 TL -7 = ACCENT TILE MANUFACURER: EUROWEST SERIES: ROVERE ILLEC'��= COLOR. NERO SIZE: 6" x 36" GROUT: JAMO, COLOR: JET BLACK CONTACT: JAN DETER 714.309.9551 LOCATION: ACCENT IN FRONT OF SERVICE COUNTER & NEW LOW WALL IN FRONT DINING TL -8 = ACCENT BASE TILE MANUFACURER: EUROWEST SERIES: ROVERE ILLEGNI COLOR: NERO GROUT: JAMO, COLOR: JET BLACK CONTACT: JAN DETER 714.309.9551 LOCATION: ACCENT IN FRONT OF SERVICE COUNTER & NEW LOW WALL IN FRONT DINING *NOTE: INSTALL NEW FLOOR TILE TO LINE UP AND MATCH WITH EXISTING FLOOR TILE :c0 D -E) L RELOCATED I ( I I o HAND SINK I I I I I •� y LLL , McDonald's reFresh 112 French Ave Sanford, FL TL -4 TL -5, 6 TL -7, 8 TL -71 II II II II II II LL II II II McDonald's reFresh 112 French Ave Sanford, FL TL -4 TL -5, 6 TL -7, 8 TL -71 Store ID: 13864 0/0: MCOPCO April 10, 2011 JL_1L -------- A i JL TL -61 rU 7Hr UL== ui uu 3 F aoVede1ya1eis'eoem ml Store ID: 13864 0/0: MCOPCO April 10, 2011 JL_1L -------- A i JL TL -61 rU 7Hr UL== ui uu Ll 3 F Ll CEILING LEGEND �� y�T���� = P-2, paint for new soffit over service I I II I I•� counter &beverage bar SEE FINISH LEGEND FOR SPECIFICATIONS FINISH & LIGHTING LEGEND: PD -1 = PENDANT LIGHTING MANUFACURER: SECURITY LIGHTING SERIES: P PENDANT MODEL: DRUM MODEL# MDP-GN-213CFL-BS SIZE: MEDIUM -22W x 14H COLOR: GN -GREEN MOUNTING MECHANISM: BS- BRUSHED STEEL RIGID STEM CONTACT: STEVE FRIEDMAN 847.830.1444 PD -2 = PENDANT LIGHTING MANUFACURER: SECURITY LIGHTING SERIES: P PENDANT MODEL: DRUM MODEL# LDP-GN-313CFL-BS SIZE: LARGE - 30W x 14H COLOR: GN -GREEN MOUNTING MECHANISM: BS- BRUSHED STEEL RIGID STEM CONTACT: STEVE FRIEDMAN 847.830.1444 WS -1 = DECORATIVE WALL SCONCE MANUFACURER: SECURITY LIGHTING MODEL# DWSM-18GU24 - WH SIZE: MEDIUM - 7.8W x 3.9D COLOR: WH -WHITE CONTACT: STEVE FRIEDMAN 847.830.1444 P-2= PAINT MANUFACURER: SHERWIN WILLIAMS COLOR: SW 6717 LIME RICKEY LOCATION: SOFFIT OVER SERVICE COUNTER & BEV. BAR P-3 = PAINT MANUFACURER: BENJAMIN MOORE COLOR: 1218 COPPER KETTLE 1. REMOVE 2x4 & l x4 FLUORESCENT LIGHITNG. REPLACE WITH RECESSED CAN LIGHITNG. 2. NEW SOFFIT WITH RECESSED LIGHTING. :(a F I I 10 PD -1 Lil --Ili, �III��6 AP 1 031 , L � McDonald's reFresh I'l 2 French Ave Sanford, FL P-2 2 L ID 9 rJL_JL-------- JLJL PD -2 m 8 11-11-011 Store ID: 1386d', 0/0: mcopco April 10, 2011 tKK MIMI SSS f 5 ,V 1 L [tf 1. QUALITY 2 GRAPHICS - SIDE DINING VIEW I Replace v 0 Indicates Required Items Indicates Highly Recommended Indicates Secondary Recommendations McDonald's reFresh 112 French Ave Sanford, FL ,leplace wall covering Remove existing artwork replace corian low wall �ap AFTER for concept only Green 1951 chair to replace ALL chairs on this wall ID 10 Store ID: 1 3864 D/o: Mco co A riI ir d e s 14, 10 i i car -in GRAPHIC DETAIL ID 11 QUALITY 2 GRAPHIC - FV -1 6 151-411 V.I.F. McDonald's reFresh 1 1 2 French Ave Sanford, FL NOTE: I, Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from corner to � corner. 0111 Remove eistin will covering on this wall and properlyprepare wall to receive new wall graphics on type II wall covering. Store ID: 13864 0/0: MCOPCO April 10, 2011 All f� z 21 11 l,,t iSS A r P 31-311 V.I.F. McDonald's reFresh ::i ......... . .. 112 French Ave ............ ...... .... .. ....... .. ........... . ........... NO ........ ... Sanford, FL NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from corner to edge of window. ProLO perly prepare wall to receive new wall graphics on type II wall covering. Use perforated wall -covering & correct adhesive for use on an exterior wall in a humid climate. VERIFY IN FIELD ALL DIMENSIONS Store ID: 13864 0/0: MCOPCO April 10, 2011 � r R it { p o -a ILA' N f =�M 3 <3 £ sf s � r R it { p o -a ILA' N 10. UALITY 2 GRAPHIC FV -1 2 M N 0 ON LO ow (if window is to remain) NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from edge of wall to corner. Properly prepare wall to receive new wall graphics on type II wall covering. Store ID: 13864 0/0: Mcopco April 10, 2011 rRlll£. S f�' s'. ....... ....••n • it" .......tF; ... .. . spF` Un.'s� g '1�' ��. 9 b }�Y £f..^ �. a >.v}gy i d.Nf ...Z%Me12-1 <ei: 'Y�:•�:.r..: .ua.� ::.:� 's...�x ;�,•#rs'.i } }} .... s°�� .. 'i#c ( ( q �i?�f 3 ?��r �f✓. .:i7�1 ... r✓ <. ✓; c7 3µj: 0 QUALITY 2 GRAPHIC - FV -1 0 61_ 1 II NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from edge of window to edge of door. Properly prepare wall to receive new wall graphics on type II wall covering. Use perforated wall -covering & correct adhesive for use on an exterior wall in a humid climate. VERIFY IN FIELD ALL DIMENSIONS Store ID: 13864 0/0: MCOPCO April 10, 2011 a s s d ....n. .� f NaiYF x ....., 3 , s?Sif-Zi a s s d ....n. .� f NaiYF x ....., 3 , QUALITY 2 GRAPHIC - FV -1 9 (A) I V.I.F. NOTA: Use area of graphic indicated by dashed lines. final size of graphic indicated. This wall graphic to cover entire wall from edge of window to edge of window. Properly prepare wall to receive new wall graphics on type II wall covering. Use perforated wall -covering & correct adhesive for use on an exterior wall in a humid climate. McDonald's reFresh 1 1 2 French Ave Sanford, FL N r- CXN LO QUALITY 2 GRAPHIC - FV -1 9 (B) 21-2 1 /2, V.I.F. NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from edge to edge. Properly prepare wall to receive new wall graphics on type II wall covering. Use perforated wall -covering & correct adhesive for use on an exterior wall in a humid climate. VERIFY IN FIELD ALL DIMENSIONS Store ID: 13864 loll cOpCo April 111., 12011 15 s` zt: z .. e �,..c��' �...rv3 ? "a" � ..r,t ,... .:•. z ;v.,: .$c. r.sa+'� '•� -� ....:a �• �%. � dz s�:��v t dtwi ��. ., s re ..?.f,.:8 �..<4: � 3.�'., >.r �.ra wsur 9, �',7 tMr,i i= �i � 3LM-�;. QUALITY 2 GRAPHIC - FV -21 8'- 11 I2„ V.I.F. McDonald's reFresh 1 1 2 French Ave Sanford, FL A, CSI QD NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This wall graphic to cover entire wall from corner to edge of window. Properly prepare wall to receive new wall graphics on U_ type II wall covering. Use perforated wall -covering & correct adhesive for use on an exterior wall in a humid climate. VERIFY IN FIELD ALL DIMENSIONS Store ID: 13864 */0: MCOPCO April 10, 2011 - - --------- - h ns I ££ g FR.:.�:`�#vim: �s✓ :;ao ;,� <,.i'.i N)....,': .� ?..$$cl5s.: :S! �µ ... J SSC, z '2 h ns I ££ g FR.:.�:`�#vim: �s✓ :;ao ;,� <,.i'.i N)....,': .� ?..$$cl5s.: :S! �µ ... J QUALITY 2 GRAPHIC - FV -20 NOTE: Use area of graphic indicated by dashed lines. Final size of graphic indicated. This graphic on Wilsonart laminate, by seating & decor or graphics company. Use 3/4" x 3/4" stainless steel vertical dowels GC to coordinate with graphic supplier & Decor Company on mounting hardware prior to fabrication of graphic. Store ID: 13864 0/0: -MCOPCO April 10, 2011 K �^ �1EADE i.Mgi `t' s <L /4 0. i' Via: �;�t ERT r ..2 11 , WALL ';�:LL s v[; ID 17 ......... ........: Y i f, rr AM n �s ......... ........: rr n �s Remove crown N place / relocate per I \',, Nl\s11—`. / 1," `..+1 1u111J Remove shutters Remove ALL corner guards McDonald's reFresh 112 French Ave Sanford, FL Remove ALL existing artwork [3 Indicates Required Items 13 Indicates Highly Recommended Indicates Secondary Recommendations Dce wall covering Replace wall scor _s Reupholster boc backs & seats ReplaCE receptc Remove shutters Store ID: 13864 0/0: MCOPCO April 10, 2011 umns!, & soffit Remove columns & soffit n f z f� J i i n J i i f. M n.✓: '., E a : QflJ, I SEEQ - Replace menu boards, unbrand center: island equipmE black tile/ scre, SEE service counter McDonald's reFresh 1 1 2 French Ave Sanford, FL SEEQ - UY the Indicates Required Items Indicates Highly Recommended Indicates Secondary Recommendations Replace ALL restroom El finishes R4 door frames Store ID: 13864 0/0: MCOPCO April 10, 2011 I Y ; Jill f ]]. HE 5 3 C.. J AM- NNE s N. pgg :: s •� � f. � ,; � sykt y,.n : 3 ,s sd11 l:. � �