Loading...
132 Towne Center Cir - BC14-000379 (FRANCESCA'S) (INTERIOR RENOVATION) (A)MI PROJECT SUMMARY THIS PROJECT IS A LEVEL 2 IEBC INTERIOR FINISH BUILD -OUT IN AN EXISTING RETAIL SPACE. THE BUILD OUT CONSISTS OF A NEW STOREFRONT, NEW INTERIOR FIXTURES, AND NEW LIGHTING THROUGHOUT. NEW ADA TOILET hOOM. EXISTING HVAC TO BE REPLACED WITH A NEW UNITS. DUCTWORK TO BE REPLACED. NEW ELECTRICAL PANEL WITH MINOR ELECTRICAL UPGRADES. THIS PROJECT IS ON THE FIRST FLOOR OF A 2 STORY BUILDING VENDOR INFORMATION Flooring Supplier: Order from Floor Zone, 10200 Hempstead Rd. 41G, Houston, TX 77092 Sales Rep. Mr. Jeff Megow, 713- 205- 6400, leffrnegowC)vahoo.com. Project Manager Mr. Phillip Murillo, 713-683-7003, p1nu1il[221lo2rzonellc.c0rn Lighting Supplier: Order frorn Weidenbach Brown, Sales Rep. Mr. Ron Doyle, 714- 982- 1538, run doyle@whlil;ht.com ;fcsupport@wblight.com. Manufacturer: MSI. xPar 38 LED lamps at 22deg spread. "crack Fixtures: NORA, NT -3046, NT -3].213, NT -31613, NT32613, NT -3058 or 3068. Low Voltage Contractor: CrossCom National, 900 Deerfield Parkway, Buffalo Grove, IL 60089. Rep. Ms. Susan Medeiros, +1 (800) 933-9203 x 6291, srnedeirosCocrosscornnatlonal.com . L HVAC/Thermostat Supplier: Trane, National Rep. Ms. Lauren Burns, 972-406-3661, lauren.burn�(wtrane.corn Stockroom Door: Masonite;36 in. x80 in. Smooth 15 -Lite French Solid Core Unfinished Pine Interior Door Slab, Horne Depot SKU 11255250 Bathroom Door: Steves and Sons Inc., 36 in. x. 80 in. Composite Unfinished 14ush Interior Door Slab, Home Depot Model /tQ68F11FCNAC99, SKU It 334219 Door knobs for Stockroom and Bathroom doors: Kwickset; Model 1197402-553/Venetian Bronze. SKU: 8- 8335107279-3. Toilet: American Standard Madera FloWise I -Piece 1.6 GPF Hig l TQP Spud Elongated Flush Valve Toilet with EverCleau in White, MFG Model 11 ;3461.001.020, MFC; Part 113461.001.020; Toilet Valve: American Standard Manual 1.26 GP1' FloWise Flush Valve for 1.5 iu. Top Spud "Toilet in Polished Chrome. MFG Model It 6047.121.002. MFG Pat It 60417.121.002 A.F.F. ABOVE FINISHED FLOOR ACOUS. ACOUSTICAL ADJ. ADJUSTABLE AL. ALUMINUM BOT. BOTTOM BD. BOARD C.L. CENTER LINE CER. ACOUSTICAL CAB. CABINET CONS -FR. CONSTRUCTION CTR CENTER CL. CENTER COL. COLUMN CONT. CONTINUOUS DWG. DRAWING ELEC. ELECTRICAL EL. OR ELEV. ELEVATION EQ. EQUAL EQPT. EQUIPMENT EX. OR EXIST. EXISTING ETR EXISTING TO REMAIN FRP FIBERGLASS REINFORCED PANELS FRT FIRE RESISTANT TREATED F.D. FLOOR DRAIN FDN FOUNDATION FTG. FOOTING G.C. GENERAL CONTRACTOR GA. GAUGE GEN. GENERAL GYP. BD. GYPSUM BOARD HC HOLLOW CORE H.M. HOLLOW METAL LAM. LAMINATE MAX. MAXIMUM MATL. MATERIAL MTL. METAL MIN. MINIMUM O.C. ON CENTER SC SOLID CORE STN. STL. STAINLESS STEEL STD. STANDARD U.N.O. UNLESS NOTED OTHERWISE V.I.F. VERIFY IN FIELD DRAWING SYMBOLS 1 A101 ELEVATION REFERENCE 1 SECTION REFERENCE A101 APPROVED FOR BUILDING PERMIT. ANY PROPOSED DEVIATION FROM THE LANDLORD APPROVED PLANS MUST BE NUMBERED AND CLOUDED ON THE PLANS, AND THEN RESUBMITTED BY THE TENANT TO THE LANDLORD FOR RE -APPROVAL PRIOR TO ANY CONSTRUCTION CHANGES TAKING PLACE IN 1 A101 DETAIL REFERENCE Name Elevation LEVEL REFERENCE ODEMOLITION REFERENCE (D SPECIFICATION REFERENCE OKEYNOTE REFERENCE 17 WALL TYPE REFERENCE ODOOR & WINDOW REFERENCE i t EQUIPMENT- REFERENCE 1t FLOOR & FINISH REFERENCE EXISTING WALLS NEW WALLS 3) CONTACT PROPERTY MANAGEMENT FOR CONSTRUCTION BARRICADE REQUIREMENTS, INCLUDING BARRICADE GRAPHICS. DEMOLISHED WALLS 200 TOWNE'OTER CIRCLE GENERAL NOTES 1) ANY DISCREPANCIES BETWEEN THE EXISTING CONDITIONS DOCUMENTS AND THE ACTUAL FIELD CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE PROCEEDING WITH ANY WORK. 2) THE CONTRACTOR SHALL REVIEW ALL DOCUMENTS AND VERIFY ALL DIMENSIONS AND FIELD CONDITIONS AND SHALL CONFIRM THAT WORK IS BUILDABLE AS SHOWN. ANY CONFLICTS OR OMISSIONS, ETC., SHALL BE IMMEDIATELY REPORTED TO THE PROJECT MANAGER FOR CLARIFICATION PRIOR TO THE PERFORMANCE OF ANY WORK IN QUESTION. 3) WHEN CONTRACTOR ACCEPTS DELIVERY OF ALL ITEMS NOTED ON PLANS WHETHER IN CONTRACT OR NOT IN CONTRACT, HE SHALL BE RESPONSIBLE FOR LOSS AND/OR DAMAGE TO THESE ITEMS. 4) THE CONTRACTOR SHALL MAINTAIN FOR THE ENTIRE DURATION OF THE WORK ALL EXITS, EXIT LIGHTING, FIRE PROTECTION DEVICES AND ALARMS IN CONFORMANCE WITH ALL APPLICABLE CODES AND ORDINANCES. 5) 'TYP.' SHOULD MEAN THAT THE CONDITION IS REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT. UNLESS OTHERWISE NOTED, DETAILS ARE USUALLY KEYED AND NOTED 'TYP.' ONLY ONCE WHEN THEY FIRST OCCUR. 6) DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS. 7) DIMENSIONS SHOWN ON PLANS ARE TO FACE OF GYPSUM BOARD, CONCRETE COLUMNS OR GRID LINES AND FACE OF EXTERIOR MASONRY UNLESS OTHERWISE NOTED OR DETAILED. 8) CONTRACTOR SHALL, IN THE WORK OF ALL TRADES, PERFORM ANY AND ALL CUTTING, PATCHING RESTORING, REPAIRING AND THE LIKE NECESSARY TO COMPLETE THE WORK AND RESTORE ANY DAMAGED SURFACES RESULTING FROM THE WORK TO THEIR ORIGINAL CONDITION. 9) EACH CONTRACTOR SHALL LEAVE THE SITE IN A NEAT, CLEAN AND ORDERLY CONDITION UPON THE COMPLETION OF HIS WORK ON A DAILY BASIS. ALL WASTE, RUBBISH AND EXCESS MATERIALS SHALL BE REMOVED FROM THE SITE PROMPTLY. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL TRASH. 10) CONTRACTOR TO PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A OR 2- A/1 OBC WITHIN 75' TRAVEL DISTANCE TO ALL PORTIONS OF THE BUILDING DURING CONSTRUCTION. 11) THE GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEIVING, SAFE STORAGE, AND COMPLETE INSTALLATION OF ALL MILLWORK. DEFERRED SUBMITTALS - SIGN SUBMITTALS CODE SUMMARY CODE DATA - FLORIDA I. GENERAL SITE AND PROJECT INFORMATION A. THIS A BUILD OUT OF A TENANT SPACE IN A MULTIPLE TENANT BUILDING. THE EXISTING SHELL BUILDING IS BEING REUSED WITH NO MODIFICATIONS TO THE EXISTING STRUCTURE. B. THE EXISTING BUILDING IS PROTECTED THROUGHOUT BY AN AUTOMATIC FIRE SUPPRESSION SYSTEM. C. PROVISIONS HAVE BEEN MADE SO THAT ALL EXITS DISCHARGE TO GRADE OR AT ACCESS TO GRADE. D. THESE CONSTRUCTION DOCUMENTS INDICATE FOR ACCESSIBILITY TO BE MAINTAINED BY THE LANDLORD FROM THE PUBLIC WAY INTO, AND THROUGHOUT, THE BUILDING TO THE LEASE SPACE. IL GOVERNING CODES BUILDING: 2010 FLORIDA BUILDING CODE MECHANICAL: 2010 FLORIDA MECHANICAL CODE ELECTRICAL: 2011 NATIONAL ELECTRICAL CODE PLUMBING: 2010 FLORIDA PLUMBING CODE ENERGY: 2010 FLORIDA ENERGY CONSERVATION CODE FIRE PROTECTION: 2010 FLORIDA FIRE PREVENTION CODE ACCESSIBILITY: 2010 FLORIDA ACCESSIBILITY CODE III. USE AND O.CCUPANCY CLASSIFICATION A. SEC. 309.1- THIS PROJECT IS A RETAIL SALES STORE CLASSIFIED AS MERCANTILE USE GROUP M. IV. TYPE OF CONSTRUCTION A. TABLE 601- CONSTRUCTION TYPE II -8 REQUIRES NO FIRE RESISTANCE RATINGS FOR STRUCTURAL FRAMING, BEARING WALLS, FLOOR CONSTRUCTION, ROOF CONSTRUCTION, INTERIOR NONBEARING WALLS & PARTITIONS. V. INTERIOR FINISHES A. TABLE 803.9- INTERIOR WALL AND CEILING FINISHES FOR OCCUPANCY GROUP M, SPRINKL.ERED, ARE CLASS B FOR VERTICAL EXITS AND EXIT PASSAGEWAYS, CLASS C FOR EXIT ACCESS CORRIDORS AND OTHER EXITWAYS, AND CLASS C FOR ROOMS AND ENCLOSED SPACES. VI. MEANS OF EGRESS A. VALUES ARE FROM PLAN LAYOUT CONTAINED IN THESE CONSTRUCTION DOCUMENTS. SALES 798 sq. ft. NON -SALES 202 sg. ft. TOTAL LEASED SQUARE FOOTAGE 1000 sq. ft. B. OCCUPANCY CALCULATION VALUES ARE FROM TABLE 1004.1.2 AND PLAN LAYOUT CONTAINED IN THESE CONSTRUCTION DOCUMENTS. SALES 798 sq. ft. 30 sq. ft. per person 27 persons NON -SALES 202 sq. ft. 300 sq. ft. per person 1 persons TOTAL OCCUPANT LOAD: 28 persons C. EGRESS WIDTH CALCULATION VALUES ARE FROM SEC. 1005.3.2 AND CALCULATIONS ABOVE. SPRINKLERED BUILDING WITH A TOTAL OCCUPANT LOAD OF 28 MULTIPLIED BY 0.2" PER OCCUPANT EQUALS 5.6" OF EXIT WIDTH REQUIRED. 96" OF EXIT WIDTH HAVE BEEN PROVIDED. KEY PLAN SWORD gOILDING DIVISION NALLY - .ESE PIANS ARE REVIEWED AND CUNDIT SHALL BE TH ACCEPTED FOR PERMIT. A ISSU EOQ PERMIT TNF YVORK DEMO PERMISSION TO PROC CANCEL, ATTER AND NOT AS AUTHORITY 1VO OVIOSIONS,OF THE TECHNICAL OR SET ASIDE ANY OF THE PR NOR SHAT-►. ISSUANCE OF A PERMIT PREVENTNO A F CODES, BUILDING DIVISION FROM CHEREAFT SR CONSTRUCTION CORRECTION OF ERRORS ON T OFT E CODE' OR OTHER VIOLATION, r -M A nir-Nr-C%f-% AIC% LANDLORD GENERAL NOTES PROJECT DIRECTORY CONTRACTOR CON -FACT TBD. ARCHITECTURAL CONTACT EMMY MCLEES WD PARTNERS 614-634-7188 emmymiclees@wdpartners.corn ENGINEERING CONTACT JOHN DEBRUHL - ELECTRICAL WD PARTNERS 614-634-7000 john.debruhl@wdpartners.corn JEFF BOLYARD - MECHANICAL WD PARTNERS 614-634-7000 jeff.bolyard@wdpartners.com CLIENT CONTACT ALBERT CHINCUANCO FRANCESCA'S SR. DIRECTOR OF CONSTRUCTION 713-864-1358 x1269 albertc@francescas.com AMANDA PETTER FRANCESCA'S CONSTRUCTION MANAGER 832-494-2274 arnanda.petter@francescas.corn PROPERTY OWNER SIMON PROPERTY GROUP 225 WEST WASHINGTON STREET INDIANAPOLIS, IN 46204 CONTACT: DAVID FLETCHER 317-263-2287 BUILDING DEPARTMENT CITY OF SANFORD, BUILDING & FIRE PREVENTION DIVISION 300 N. PARK AVE. SANFORD, FL 32771-1788 407-688-5150 is AIR PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. I. i 200 TOWNE CENTER CIRCLE, SPACE #D11 C_ APPROVED FOR BUILDING PERMIT. ANY PROPOSED DEVIATION FROM THE LANDLORD APPROVED PLANS MUST BE NUMBERED AND CLOUDED ON THE PLANS, AND THEN RESUBMITTED BY THE TENANT TO THE LANDLORD FOR RE -APPROVAL PRIOR TO ANY CONSTRUCTION CHANGES TAKING PLACE IN SANFORD, FL 32771 THE FIELD. DRAWN BY: I WD PROJECT NUMBER k FRCC00050 1) PLANS REVIEWED AND APPROVED BY LANDLORD'S TENANT COORDINATOR MUST BE PRESENT ON THE JOB SITE AND BE ACCOMPANIED BY PLANS APPROVED FOR BUILDING PERMIT. ANY PROPOSED DEVIATION FROM THE LANDLORD APPROVED PLANS MUST BE NUMBERED AND CLOUDED ON THE PLANS, AND THEN RESUBMITTED BY THE TENANT TO THE LANDLORD FOR RE -APPROVAL PRIOR TO ANY CONSTRUCTION CHANGES TAKING PLACE IN THE FIELD. a u 2) TENANT'S GC IS REQUIRED TO CHECK IN WITH LANDLORD'S ON SITE PROPERTY MANAGER PRIOR TO THE START OF TENANT CONSTRUCTION. CONTACT 'NOV�� 10 MALL MANAGEMENT OFFICE. 3) CONTACT PROPERTY MANAGEMENT FOR CONSTRUCTION BARRICADE REQUIREMENTS, INCLUDING BARRICADE GRAPHICS. H E ET I N ®EX 4) TENANT'S GC IS RESPONSIBLE TO COMPLY WITH ALL MALL RULES AND REGULATIONS AND AS INSTRUCTED ON SITE BY MALL MANA(3EMENT. ISSUE DATES 5) ANY DAMAGE TO LANDLORD'S PROPERTY DURING TENANT DEMOLITION OR CONSTRUCTION (MALL FLOORING, BULKHEAD, NEUTRAL PIERS, ETC.) WILL T1 TITLE SHEET PRELIM SET: 10-16-2013 BE REPAIRED PER MALL SPECIFICATIONS, AT TENANT'S EXPENSE.T2 RESPONSIBILITY SCHEDULE 0 FINAL SET: 11-6-2013 6) ANY LANDLORD EQUIPMENT OR COMPONENT THAT IS EXISTING IN THE SPACE MUST REMAIN VISIBLE AND ACCESSIBLE TO THE LANDLORD. TENANT TOCC CODE COMPLIANCE] PERMIT SET: 11-20-2013 INSTALL ACCESS PANELS AS NECESSARY, AND PROPERLY LABEL IN SPACE. D1 DEMO PLAN 7) ALL LANDLORD COMMENTS FROM PREVIOUS REVIEW(S) ARE TO BE ADHERED TO IN THE FIELD. Al 3D RENDERING a 8) ALL LANDLORD COMMENTS ON THIS SET OF DRAWINGS APPLY TO THE ENTIRE DOCUMENT SET, EVEN IF NOT REPEATED ON EVERY SHEET IN DRAWING A1.1 FLOOR PLAN oct S ET. A2 i REFLECTED CEILING PLAN REVISIONS 9) THE RE -USE OF ANY EXISTING CONSTRUCTION, FINISHES, EQUIPMENT, OR ELECTRICAL, PLUMBING,, OR HVAC SYSTEMS CURRENTLY IN THE SPACE IS A3 STOREFRONT ELEVATIONS s CONDITIONAL UPON IT BEING APPROPRIATE FOR RE -USE. ANY EXISTING-; CONDITION OR EQUIPMENT TO BE RE -USED MUST BE RESTORED TO LIKE NEW CONDITION. THE LANDLORD MAKES NO WARRANTY ON THE RE -USE OF ANY EXISTING CONDITION IN THE SPACE. A3.1 STOREFRONT SECTIONS 10) IF AT ANY POINT FAILURES OR UPGRADES OR IMPROVEMENTS TO EXISTING SYSTEMS OCCUR, If IS THE SOLE RESPONSIBILITY OF THE TENANT TO A4 INTERIOR ELEVATIONS REPAIR OR REPLACE, AT TENANT'S EXPENSE.�,/� �`--- 11) LANDLORD AND TENANT RESPONSIBILITIES ARE AS DEFINED IN LEASE AGREEMENT. M1 MECHANICAL PLAN 12) TENANT IS REQUIRED TO INSTALL A WATERPROOF MEMBRANE IN ALL WET AREAS OF SPACE. TENANT SHALL USE A 30 MIL POLYETHYLENE CLEAVAGE M2 MECHANICAL DETAILS MEMBRANE (EQUAL TO NOBLESEAL TS) INSTALLED PER MANUFACTURER'S RECOMMENDATIONS AND ANSI A-108. MEMBRANE MUST BE EXTENDED UP M3 MECHANICAL SPECIFICATIONS THE WALL A MINIMUM OF 4" OR EQUAL TO THE HEIGHT OF THE FLOOR BASE. =r 13) FLOOR PENE=TRATIONS: TENANT'S GC MUST ADVISE THE PROPERTY'S OPERATIONS DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE E1 ELECTRICAL POWER PLAN CORE -BORED OR SAW -CUT (NO JACK -HAMMERING IS PERMITTED). PRIOR TO WORK, TENANT'S GC MUST VERIFY THAT TENANT'S WORK WILL NOTE2 ELECTRICAL LIGHTING PLAN DRAWING NUMBER CONFLICT WITH EXISTING STRUCTURAL, UTILITY, OR OTHER UNDER -SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANT'S EXPENSE. E3 ELECTRICAL RISER AND SCHEDULES z 14) ALL LANDLORD COMMENTS FROM PREVIOUS REVIEW(S) STILL APPLY AND ARE TO BE INCORPORATED INTO THIS SET OF DRAWINGS AND THE FINAL SET E4 ELECTRICAL SPECIFICATION OF DRAWINGS. LANDLORD COMMENTS FROM PREVIOUS REVIEWS ARE TO BE STRICTLY ADHERED TO, IF NOT ALREADY INCLUDED ON THE DRAWINGS. 15) ALL ROOFING, SPRINKLER, & FIRE PROTECTION WORK MUST BE PERFORMED BY LANDLORD APPROVED CONTRACTOR AT THE TENANT'S EXPENSE. CONTACT DAVID MILLER, OPERATIONS DIRECTOR, AT 407-323-1843 FOR CONTACT INFORMATION. E 16) PRIOR TO STARTING ANY CONSTRUCTION, THE TENANT OR TENANT'S GENERAL CONTRACTOR IS REQUIRED TO HAVE A PRECONSTRUCTION MEETING TITLE SHEET WITH THE PROPERTY OPERATIONS DIRECTOR OR MALL MANAGEMENT. CONTACT DAVID MILLER, OPERATIONS DIRECTOR, AT 407-323-1843.UO _ PROJECT I N �-O 17) PLANS REVIEWED & APPROVED BY LANDLORD'S TENANT COORDINATOR MUST BE PRESENT ON THE JOBSITE & ACCOMPANIED BY THE APPROVED BUILDING DEPARTMENT PLANS. ANY DEVIATION FROM LANDLORD APPROVED PLANS MUST BE RESUBMITTED TO LANDLORD FOR APPROVAL. CONTACT DAVID FLETCHER AT 317-263-2287. „ ..., ,.... ..., . _ I r ., .,.,.:.r .,..,.....,, ,. ..,.. ,.... „,..... ., ,r .>r. x. ,.. ,r.., .,: a..a a,w..,,a.,, ..,.,, „ ... .......... .. ... , ,. r.,' „ :.:. :,., t: , , .z x,a, r. r.,a.xL,. vxa „ .av x..:. ...,,,.,.. ... .'ii' ..x ,,, ,,,,, x t e4s, zx, ,.u,.. x.v .. . r .. .... , ........, ,.,x, , r. ;..r: 4 u. .. i .... .,, ! , , u , ..,,:,r r..,x .r:.:. ., i, x,r..;. „r. ..«i:a ..., ,.::.':. , ..,. .. ti"' . .... ... .... . a i r xaa ', ..a c n.., .. a . .i$ rt. • „ t, x.... „ V%d PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMIN®LE T.C. 200 TOWNE CENTER CIRCLE SPACE #I311C SANFORD, PL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ADY 2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 ED PERMIT SET: 11-20-2013 REVISIONS FFA DRAWING NUMBER RESPONSIBILITY SCHEDULE ,a,i � ,�; ,<:: a , . :!. a,,.i: 3.•; a ,:,d .; ,x-': a ,,:: ,,...:r :... .:.:. .. .. : ...: .'.< �.'.>r'•,. ...,. ��.. ... ,.: x, .,:: �. r'r 4ti 'ur n:r .. r r r .I r�i r.y Ir;;rY ui�r tj:r' ., .. .r ,. ,., .. .. ,.., .... ... z� F= in ® i inm RESPONSIBILITY � C H I I ED �J � � � z in W m � rn © KEY V- EXISTING F - FIXTURE VENDOR A- ARCHITECT L- LANDLORD C - GENERAL CONTRACTOR T - TENANT ITEM DESCRIPTION ITEM DESCRIPTION 01 GENERAL REQUIREMENTS 09 FINISHES (CONTINUED) 1. PERMITS AND FEES 6. BASE A. BLDG. PERMIT SUBMITTAL JA JAS REQUIRED BY LOCAL BLDG. DEPARTMENT A. RESTROOM C C REFER TO FINISH SCHEDULE FOR MATERIAL USED B. PERMIT FEES & PICK UP C AS REQUIRED BY LOCAL BLDG. DEPARTMENT B. STOCK ROOM C CI REFER TO FINISH SCHEDULE FOR MATERIAL USED C. SIGN PERMIT T BY TENANT'S COMMERCIAL SIGN COMPANY C. SALES AREA T C GC INSTALL, SUPPLIED BY FRANCESCA'S D. SIGN PLAN CHECK FEE TI BY TENANT'S COMMERCIAL SIGN COMPANY D. STOREFRONT BASE IC C REFER TO FINISH SCHEDULE FOR MATERIAL USED E. OTHER C ALL OTHERS AS REQUIRED BY LOCAL BLDG. & FIRE DEPARTMENTS 7. CEILING 2. INSPECTIONS C C AS REQUIRED BY LOCAL BLDG. & FIRE DEPARTMENTS A. SALES AREA C CI SEE RCP 3. TEMPORARY HEAT C Cl- B. STOCK ROOM C C SEE RCP 4. TEMPORARY ELECTRIC C C - C. RESTROOM C C SEE RCP 5. TEMPORARY BARRICADE C C G.C. TO CONSTRUCT PER LL REQUIREMENTS 8. WALL FINISHES 6. CLEAN UP C C DAILY SWEEP CLEANING DURING CONSTRUCTION, AND FINAL "WHITE GLOVE" CLEANING A. PAINT IC ClAS SHOWN ON PLANS AND ELEVATIONS 7. BUILDERS RISK INSURANCE C C AS REQUIRED BY TENANT AND LANDLORD B. FRP AT RESTROOM WET WALLS) C C 02 SITE WORK 10 SPECIAL11ES 1. SAW CUT SLAB C C AS REQUIRED 1. RESTROOM ACCESSORIES C C GC TO PROVIDE AND INSTALL ALL NEW ACCESSORIES IF NEEDED. 2> DEMOLITION C C AS REQUIRED TO CONSTRUCT SPACE 2. ACCESS PANEL N/A 3. CORE DRILL C C AS REQUIRED 3. AWNING N/A 4. KNOX BOX (KEY BOX) N/A 03 CONCRETE WORK 5. STOREFRONT WOOD ELEMENT VA - 1. SAND PAD -- 2. VAPOR BARRIER C C GC TO REPAIR ANY AREAS ALTERED BY DEMOLITION 11 EQUIPMENT 3. REINFORCING FABRIC 1. STOREFRONT SIGNAGE ALL SIGNAGE SUPPLIED AND INSTALLED BY TENANT'S SIGN SUPPLIER / CONTRACTOR 4. CONCRETE SLAB C C GC TO REPAIR ANY AREAS ALTERED BY DEMOLITION A. WALL SIGNS T T PER LANDLORD REQUIREMENTS 5. POURED CONCRETE J B. BLADE SIGN N/A 6. FLOOR PATCH C C AS REQUIRED INCLUDING AT MATERIAL TRANSITIONS 2. FIRE EXTINGUISHERS C C INSTALL PER PLAN AND / OR CODE REGULATIONS 7. IN -FILL AT STOREFRONT N/A 3. CASH REGISTERS IT TI INSTALLATION BY TENANT REPRESENTATIVE 04 MASONRY 12 FURNISHINGS_ 1. CONCRETE BLOCK N/A 1. WALL SHELVES T C GC INSTALL, SUPPLIED BY FRANCESCA'S 2. CASH WRAP BACK WRAP AREA T C GC INSTALL, SUPPLIED BY FRANCESCA'S 05 METALS 3. MIRRORS OTHER FURNITURE T C GC INSTALL, SUPPLIED BY FRANCESCA'S 1. STRUCTURAL STEEL ✓ 4. DISPLAY TABLE & RACK T C SUPPLIED BY FRANCESCA'S 2. METAL STUDS C C AS REQUIRED TO CONSTRUCT SPACE A. DEMISING WALLS ✓ L L G.C. TO PATCH AND REPAIR AS REQUIRED 13 SPECIAL CONSTRUCTION N/A B. INTERIOR PARTITIONS / FRAMING C C G.C. TO PROVIDE AND INSTALL NEW AS PER DRAWINGS C. SOFFITS C C 15 MECHANICAL D. STOREFRONT FRAMING C C G.C. TO PROVIDE AND INSTALL NEW AS PER DRAWINGS 1. HVAC C CI SEE MECH. PLAN E. METAL FURRING C C 2. HVAC DIFFUSERS C C SEE MECH. PLAN. 3. DOOR OPENING FRAME 3. HVAC DUCTWORK C C SEE MECH. PLAN A. GLASS WOOD DOOR FRAMING C C REFER TO DOOR SCHEDULE 4. TEMPERATURE CONTROLS C C SEE MECH. PLAN 4. REVEAL AT STOREFRONT N LA 5. EXHAUST FAN C C SEE ELECT. AND MECH. PLAN 5. CEILING EDGE C C 6. PLUMBING LANDLORD PROVIDE STUBS 6. FURRING STRIP C C A. WATER C C REFER TO MECHANICAL SHEETS B. WASTE C C REFER TO MECHANICAL SHEETS 06 CARPENTRY MILLWORK C. VENT C C REFER TO MECHANICAL SHEETS 1. BUILT --IN DISPLAY PLATFORM C C FINISH WOOD SUPPLIED BY TENANT, BUILT AND INSTALLED BY GC 7. PLUMBING FIXTURES C I C I REFER TO MECHANICAL SHEETS 2, WALL SHELF BLOCKING C C SUPPLIED AND INSTALLED BY GC AS NEEDED AT WALL FIXTURES 8. WATER HEATER C C REFER TO MECHANICAL SHEETS 3. STOCKROOM SHELF BLOCKING C C SUPPLIED AND INSTALLED BY GC AS NEEDED AT WALL FIXTURES 9. SPRINKLER SYSTEM N/A 4. FITTING ROOM AND ACCESSORIES T C SUPPLIED BY TENANT, BUILT AND INSTALLED BY GC 10. WATER METER C C REFER TO MECHANICAL SHEETS 5. WOOD BLOCKING C C ALL BLOCKING TO BE FIRE RETARDANT TO CODE 6. PLYWOOD C C FIRE RETARDANT TREATED PLYWOOD 7. STAINED WOOD AT STOREFRONT C C IF APPLICABLE, BUILT AND INSTALLED BY GC 8. TRIM C C IF APPLICABLE, BUILT AND INSTALLED BY GC 16 ELECTRICAL LANDLORD INSTALLS EMPTY CONDUIT. TENANT GC IS RESPONSIBLE TO PULL THE WIRE FOR ELECTRICAL AND TELEPHONE. 07 THERMAL MOISTURE CONTROL 1. SERV. TO MAIN DISCONNECT C C REFER TO ELECTRICAL SHEETS 1. WATERPROOFING MEMBRANE C C G.C. TO SUPPLY AND INSTALL PER LL REQUIREMENTS 2. DIST. IN TENANT SPACE ✓ C C REFER TO ELECTRICAL SHEETS 2. CAULKING C C MAINTAIN CODE REQUIRED CONDITIONS 3. METERING C C REFER TO ELECTRICAL SHEETS 3. INSULATION ✓ C C MAINTAIN CODE REQUIRED CONDITIONS 4. PANELS C C I G.C. TO REPLACE EXISTING PANEL WITH NEW. REFER TO ELECTRICAL SHEETS 4. FIREPROOFING C C MAINTAIN CODE REQUIRED CONDITIONS 5. TRANSFORMER N/A 6. MAIN CONDUIT TO SPACE C C REFER TO ELECTRICAL SHEETS 08 DOORS /WINDOWS 7. MAIN CONDUCTOR TO SPACE C C REFER TO ELECTRICAL SHEETS 1. STOREFRONT ROLLING GRILLE C ClG.C. TO INSTALL NEW ROLLING GRILLE & HARDWARE PER DRAWINGS 8. TELEPHONE IT C 2. STOREFRONT GLAZING SYSTEM C C G.C. TO PROVIDE AND INSTALL NEW STOREFRONT MATERIALS AS SHOWN IN DRAWINGS A. LOW VOLTAGE, J -BOXES, CONDUITS C C GC TO INSTALL J -BOX AND CONDUIT WITH PULL STRING. READY FOR TENANTS EQUIPMENT TO PLUG IN A. EXISTING N/A B. TEMPERED GLASS N/A 9. DOOR BELL AT REAR ENTRY N/A C. STOREFRONT METAL N/A 10. LIGHT FIXTURES - 3. RESTROOM DOOR C C G.C. TO INSTALL NEW DOOR & HARDWARE PER DRAWINGS A. SALES AREA T C REFER TO ELECTRICAL SHEETS 4. STOCKROOM DOOR C C G.C. TO INSTALL NEW DOOR & HARDWARE PER DRAWINGS B. STOCKROOM T C REFER TO ELECTRICAL SHEETS. 5. SERVICE DOOR N/A C. RESTROOM T C REFER TO ELECTRICAL SHEETS D. STOREFRONT SOFFIT T C REFER TO ELECTRICAL SHEETS 09 FINISHES E. TRACK FIXTURES IT C REFER TO ELECTRICAL SHEETS 1. GYPSUM BOARD (NE C C Jr TYPE "X" GYP. BD. - TAPED AND SANDED F. EXIT EMERGENCY LIGHTS T C REFER TO ELECTRICAL SHEETS. GYPSUM BOARD (EXIST.) C C EXIST. TO REMAIN - PATCH OR REPAIR AS REQ'D PRIOR TO INSTALL OF NEW FINISHES G. TRACK RAIL T C REFER TO ELECTRICAL SHEETS _2. 3. BACKER BOARD C C H. FIXTURE LAMPS T C REFER TO ELECTRICAL SHEETS 4. FLOORING J. WALL SCONCE & CHANDELIER T C REFER TO ELECTRICAL SHEETS A. SALES AREA FLOOR T C REFER TO FINISH SCHEDULE FOR MATERIAL USED 11. ELECTRICAL OUTLETS J C C INSTALL AS PER PLANS B. MALL FLOORING N A 12. SMOKE DETECTORS ✓ C C INSTALL AS PER PLANS C. RESTROOM C C REFER TO FINISH SCHEDULE FOR MATERIAL USED 13. STEREO SPEAKERS C C COORDINATE WITH TENANT D. STOCK ROOM C C REFER TO FINISH SCHEDULE FOR MATERIAL USED - E. METAL TRANSITIONS C C 5. COUNTER TOP RESTROOM) N/A V%d PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMIN®LE T.C. 200 TOWNE CENTER CIRCLE SPACE #I311C SANFORD, PL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ADY 2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 ED PERMIT SET: 11-20-2013 REVISIONS FFA DRAWING NUMBER RESPONSIBILITY SCHEDULE ,a,i � ,�; ,<:: a , . :!. a,,.i: 3.•; a ,:,d .; ,x-': a ,,:: ,,...:r :... .:.:. .. .. : ...: .'.< �.'.>r'•,. ...,. ��.. ... ,.: x, .,:: �. r'r 4ti 'ur n:r .. r r r .I r�i r.y Ir;;rY ui�r tj:r' ., .. .r ,. ,., .. .. ,.., .... ... OWALKS AND SIDEWALKS A. WALKS AND SIDEWALKS SHALL, HAVE A CONTINUOUS COMMON SURFACE NOT INTERRUPTED BY STEPS OR BY ABRUPT CHANGES IN LEVEL EXCEEDING 1/4 INCH, AND SHALL BE A MINIMUM OF 4 FEET IN WIDTH, B. SURFACES WITH A SLOPE OF LESS THAN 6 PERCENT GRADIENT SHALL BE AT LEAST AS SLIP RESISTANT AS THAT DESCRIBED AS A MEDIUM SALTED FINISH. C. SURFACES WITH A SLOPE OF 6 PERCENT GRADIENT OR GREATER SHALL BE SLIP -RESISTANT. D. SURFACE CROSS SLOPES SHALL NOT EXCEED 1/4 INCH PER FOOT. E. WALKS, SIDEWALKS AND PEDESTRIAN WAYS SHALL BE FREE OF GRATING WHENEVER POSSIBLE. FOR GRATINGS LOCATED IN THE SURFACE OF ANY OF THESE AREAS, GRID OPENINGS IN GRATINGS SHALL BE PERPENDICULAR TO THE PROMINENT DIRECTION OF TRAVEL, AND A MAXIMUM OF 1/2" IN SIZE. F. WHEN THE SLOPE IN THE DIRECTION OF TRAVEL OF ANY WALK EXCEEDS 1 VERTICAL TO 20 HORIZONTAL IT SHALL COMPLY WITH THE PROVISIONS FOR PEDESTRIAN RAMPS. G. ABRUPT CHANGES IN LEVEL ALONG ANY ACCESSIBLE ROUTE SHALL NOT EXCEED 1/2 INCH. WHEN CHANGES IN LEVEL DO OCCUR, THEY SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2 EXCEPT THAT LEVEL CHANGES NOT EXCEEDING 1/4 INCH MAY BE VERTICAL. WHEN CHANGES IN LEVEL GREATER THAN 1/2 INCH ARE NECESSARY COMPLY WITH THE REQUIREMENTS FOR CURB RAMPS. H. WALKS SHALL BE PROVIDED WITH A LEVEL AREA NOT LESS THAN 60 INCHES BY 60 INCHES AT A DOOR OR GATE THAT SWINGS TOWARD THE WALK, AND NOT LESS THAN 48 INCHES WIDE BY 44 INCHES DEEP THAT A DOOR OR GATE THAT SWINGS AWAY FROM THE WALK. SUCH WALKS SHALL EXTEND 24 INCHES TO THE SIDE OF THE STRIKE EDGE OF A DOOR OR GATE THAT SWINGS TOWARD THE WALK. I. ALL WALKS WITH CONTINUOUS GRADIENTS SHALL HAVE LEVEL AREAS OF AT LEAST 5 FEET IN LENGTH AT INTERVALS OF AT LEAST EVERY 400 FEET. J. IF A WALK CROSSES OR ADJOINS A VEHICULAR WAY, AND THE WALKING SURFACES ARE NOT SEPARATED BY CURBS, RAILINGS OR OTHER ELEMENTS BETWEEN THE PEDESTRIAN AREAS AND VEHICULAR AREAS, THE BOUNDARY BETWEEN THE AREAS SHALL BE DEFINED BY A CONTINUOUS DETECTABLE WARNING WHICH IS 36 INCHES WIDE. SEE DETECTABLE WARNING TEXTURE DETAIL. @TACTILE SIGNAGE_ A. SIGNS IDENTIFYING PERMANENT ROOMS OR SPACES OR PROVIDING INFORMATION OR DIRECTION, TO INCLUDE RAISED CHARACTERS, CONTRACTED GRADE II BRAILLE AND PICTURIAL SYMBOLS. B. WHEN SIGNS IDENTIFY, OR GIVE INFORMATION ABOUT ACCESSIBLE ELEMENTS AND FEATURE OF A BUILDING OR SITE, THEY SHALL INCLUDE THE APPROPRIATE SYMBOL OF ACCESSIBILITY OR PICTOGRAM, WITH THE EQUIVALENT VISUAL AND TACTILE DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE OUTSIDE BORDER OF THE PICTOGRAM SHALL BE MINIMUM 6" IN HEIGHT. C. VISUAL CHARACTERS SHALL BE UPPERCASE, STANDARD SANS SERIF FONT. VISUAL CHARACTERS TO HAVE A WIDTH -TO -HEIGHT RATION OF BETWEEN 3:5 AND 1:1 MEASURED BY THE WIDTH OF AN UPPERCASE 0 & THE HEIGHT OF AN UPPER CASE I & A STROKE WIDTH -TO -HEIGHT RATIO OF BETWEEN1:5 & 1&10 MEASURED BY THE WIDTH OF AN UPPERCASE I. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND. CHARACTERS, SYMBOLS AND BACKGROUNDS SHALL HAVE A NON -GLARE FINISH. D. TACTILE CHARACTERS SHALL BE UPPERCASE, STANDARD SANS SERIF FONT, RAISED 1/32" OFF THE BACKGROUND. THE HEIGHT OF TACTILE CHARACTERS SHALL BE BETWEEN 5/8" AND 2". CHARACTERS SHALL BE ACCOMPANIED BY GRADE II BRAILLE LOCATED 3/8 MIN. BELOW BOTTOM EDGE OF CHARACTER. E. GRADE 2 BRAILLE SHALL HAVE DOMED OR ROUNDED DOTS RAISED 1/40" OFF THE BACKGROUND, WITH DOTS SPACED 1/10" WITH -IN CELLS, AND 2/10" BETWEEN CELLS. F. TACTILE SIGNS SHALL BE MOUNTED 48" MINIMUM, TO THE BASELINE OF THE LOWEST TACTILE LETTER, AND 60" MAXIMUM ABOVE THE FLOOR TO THE BASELINE OF THE HIGHEST TACTILE LETTER. AN 18" X 18" CLEAR SPACE IS REQUIRED IN FRONT OF THE TACTILE SIGN, BEYOND THE ARC OF ANY DOOR SWING. WHERE SIGNS ARE MOUNTED AT DOORS, THE SIGN SHALL BE ON THE LATCH SIDE OF THE DOOR. WHERE SIGNS ARE MOUNTED AT DOUBLE DOORS, OR WHERE THERE IS NO WALL SPACE, THE SIGN SHALL BE MOUNTED ON THE NEAREST ADJACENT WALL, PREFERABLY THE RIGHT SIDE. @RAMPS A. ANY PATH OF TRAVEL SHALL BE CONSIDERED A RAMP IF ITS SLOPE IS GREATER THAN 1:20 (1:12 MAXIMUM) B. 1:12 SLOPED RAMPS WITH LENGTH GREATER THAN 72" SHALL HAVE HANDRAILS ON BOTH SIDES. C. THE TOP LANDINGS ON A RAMP MUST BE AT LEAST 60 INCHES IN DEPTH. D. IF A DOOR SWINGS ONTO ATOP LANDING, THE MIN. LANDING DIMENSION SHALL BE NOT LESS THAN 42 INCHES CLEAR PLUS THE WIDTH OF THE DOOR. E. THE TOP LANDING SHALL HAVE A WIDTH NOT LESS THAN ITS DEPTH. F. THE TOP LANDING SHALL EXTEND NOT LESS THAN 24 -INCHES BEYOND THE STRIKE SIDE OF THE DOOR AT EXTERIOR RAMPS AND 18 -INCHES AT INTERIOR RAMPS. G. THE BOTTOM LANDING SHALL BE NOT LESS THAN69 INGI IEG (CA: 72 INCHES) DEEP H. INTERMEDIATE LANDINGS SHALL BE PROVIDED AT TURNS AND WHENEVER THE CHANGE IN LEVEL EXCEEDS 30 INCHES, 60" MIN. I. INTERMEDIATE LANDINGS ON RAMPS SHALL HAVE A DEPTH OF NOT 3" MAXI ? LESS THAN 5'-0". WHERE A (CA: 30 DEGREE CHANGE) GHANGE IN RAMP DIRECTION OCCURS, A MINIMUM 72" BY 72" LANDING SHALL BE PROVIDED. RAMP J. RAMPS SHALL BE NOT LESS THAN 4'-0" WIDE. RAMPS SERVING A DOWN PRIMARY ENTRANCE FOR AN OCCUPANT LOAD OF 300 OR MORE 24" EXTERIOR PEOPLE SHALL BE NOT LESS THAN 5'-0" WIDE. LANDING AT RAMP 18" INTERIOR K. HANDRAILS SHALL BE PLACED ON EACH SIDE OF EACH RAMP AND SHALL BE CONTINUOUS THE FULL LENGTH OF THE RAMP. HANDRAILS SHALL BE 34 TO 38 INCHES ABOVE THE RAMP SURFACE AND EXTEND A MINIMUM OF 1 FOOT BEYOND THE TOP AND BOTTOM OF THE RAMP. L. SURFACES OF RAMPS SHALL BE SLIP -RESISTANT. M. RAMPS & LANDINGS WITH DROP OFFS SHALL HAVE CURBS, WALLS, RAILING OR PROJECTING SURFACES THAT PREVENT PEOPLE FROM SLIPPING OFF THE RAMP. CURB SHALL BE A MIN. 2" IN HEIGHT. MAXIMUM ELEVATION CHANGE BETWEEN LANDINGS IS 30". ODOORS A. LATCHES AND LOCKSETS: PROVIDE LEVER TYPE, PUSH- PULL OR PANIC TYPE HARDWARE 34 INCHES TO 48 INCHES ABOVE FLOOR. B. ADJUSTABLE CLOSURE PROVIDED WITH MAXIMUM PRESSURE FOR OPENING DOORS AS FOLLOWS: INTERIOR DOORS - 5 POUNDS PRESSURE EXTERIOR DOORS - 8.5 POUNDS PRESSURE FIRE DOORS - PER ADMINISTRATIVE AUTHORITY DOOR CLOSURES TO BE ADJUSTED TO CLOSE FROM AN OPEN POSITION OF 90 DEG IN NOT LESS THAN 5 SECONDS TO A POINT 12" FROM LATCH. ADJUST CLOSURES AFTER INSTALLATION AND TEST DOOR COMPLIANCE. C. FLOOR LEVEL AT DOORS 1. THRESHOLDS: THE FLOOR OR LANDING SHALL NOT BE MORE THAN 1/2 INCH LOWER THAN THE THRESHOLD OF THE DOOR WAY. CHANGE IN LEVEL BETWEEN 1/4 INCH AND 1/2 INCH SHALL BE BEVELED WITH A SLOPE NO GREATER THAN 1:2. (SEE BELOW). 21 � 1/2" MAX. THRESHOLDS 1/4 MAX. 2. LEVEL FLOOR OR LANDING: THERE SHALL BE A LEVEL AND CLEAR AREA ON EACH SIDE OF AN EXIT DOOR. THE LEVEL AREAS SHALL BE AS SHOWN BELOW. THE SPACE BETWEEN TWO CONSECUTIVE DOOR OPENING (VESTIBULE) SHALL PROVIDE 48 INCHES OF CLEAR SPACE FROM ANY DOOR OPENING INTO SUCH SPACE (SEE BELOW). FPPULL SIDE I F PULL SIDE - pw I I I I X=36"MIN IF Y=60" z p of 24" MIN. OR [IX X=42"MIN IF t I Y = 54" I mea ��s LU ZOO I pU) o o — \ I O I x+-24" MIN. � I24" MIN. ��¢z z = LPUSH SIDE J _ ¢ I PUSH SIDE 10" MIN. BOTTOM RAIL LAFCH APPROACH HINGE APPROACH OR PROVIDE KICK PLATE AT PUSH SIDE F PULL SIDE 177.7 z I j � I 18" MIN. SPACE IS NECESSARY TO ALLOW BACKING AND TURNING SPACE FOR A WHEELCHAIR TO CLEAR THE IN -SWINGING DOOR. PROVIDE THIS 32" / z /I < I I ADDITIONAL SPACE IF CLR. co DOOR IS EQUIPPED WITH BOTH A LATCH LUSH SICIEJ AND A CLOSER. 12" MIN. FRONT APPROACH VESTIBULE D. DOOR WIDTH & HEIGHT: 3 FEET WIDE AND 6 FEET 8 INCHES HIGH. CLEAR WIDTH: 32 INCHES MINIMUM WITH DOOR OPEN 90 DEG. MEASURED FROM THE FACE OF THE DOOR TO THE OPPOSITE STOP. E. THE BOTTOM 10 INCHES OF ALL DOORS EXCEPT AUTOMATIC AND SLIDING SHALL HAVE A SMOOTH UNINTERRUPTED SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. (DPROTRUDING OBJECTS: KNEE AND TOE CLEARANCE A. PROJECTIONS FROM WALLS WITH LEADING EDGE BETWEEN 27" AND 80" ABOVE FLOOR MAY PROJECT 4" MAXIMUM. LEADING EDGE AT OR BELOW 27" MAY PROJECT ANY AMOUNT. FREE STANDING PROJECTION, WITH LEADING EDGE BETWEEN 27" AND 80" ABOVE FLOOR MAY PROJECT 12" MAX. PROJECTIONS MAY NO - REDUCE MANEUVERING SPACE, OR CLEAR WIDTH OF f ACCESSIBLE ROUTE. B. HEAD ROOM: 80" MINIMUM. OELECTRICAL A. ELECTRICAL RECEPTACLES (15, 20 AND 30 AMPS) SHALL BE AT LEAST 15 INCHES ABOVE THE FLOOR. B. SWITCHES AND CONTROLS FOR LIGHTS, APPLIANCES, COOLING, HEATING AND VENTILATING EQUIPMENT SHALL BE NOT LESS THAN 3 FEET NOR MORE THAN 4 FEET ABOVE THE FLOOR. C. FIRE ALARM INITIATING DEVICES SHALL BE 48 INCHES MAX ABOVE THE FLOOR, GROUND OR SIDEWALK. OPUBLIC TELEPHONES A. A CLEAR FLOOR OR GROUND SPACE AT LEAST 30 INCHES IN BY 48 INCHES THAT ALLOWS EITHER A FORWARD OR PARALLEL APPROACH BY A PERSON USING A WHEELCHAIR SHALL BE PROVIDED AT TELEPHONES. BASES, ENCLOSURES, AND FIXED SEATS SHALL NOT IMPEDE APPROACHES BY PEOPLE WHO USE WHEELCHAIRS. B. THE HIGHEST OPERABLE PART OF THE TELEPHONE SHALL BE NO HIGHER THAN 48 INCHES ABOVE FINISH FLOOR. @ DDS KING --FOUNTAINS A. NOT REQUIRED - ACCORDING TO SECTION 410.3:.... IN OTHER OCCUPANCIES, WHERE DRINKING FOUNTAINS ARE REQUIRED, WA'T'ER COOLERS OR BOTTLED WATER DISPENSERS SHALL BE PERMITTED TO BE SUBSTITUTED FOR NOT MORE THAN 50 PEKCENTOF THE REQUIRED NUMBER OF DRINKING FOUNTAINS. @SANITARY FACILITIES A. GEOMETRICAL SYMBOLS 1. UNISEX SANITARY FACILITIES SHALL BE IDENTIFIED BY A CIRCLE 1/4 INCH THICK, 12 INCH DIAMETER, WITH A 1/4" THICK TRIANGLE SUPERIMPOSED ON THE CIRCLE AND WITHIN THE 12 INCH DIAMETER. 2. GEOMETRIC (CIRCLE AND TRIANGLE) SYMBOLS ON SANITARY DOORS SHALL BE CENTERED ON THE DOOR AT A HEIGHT OF 60" AND THEIR COLOR AND CONTRAST SHALL BE DISTINCTLY DIFFERENT. 3. RAISED LETTERS SHALL BE PROVIDED IN CONFORMANCE TO ANSI SECTION 703.4.2 AND ACCOMPANIED BY GRADE II BRAILLE PER ANSI 703.5 AND SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT DOUBLE LEAF DOORS, SIGNS SHALL BE PLACED ON THE NEAREST ADJACENT WALL, PREFERABLY ON THE RIGHT. MOUNTING HEIGHT SHALL BE SUCH THAT BRAILLE IS BETWEEN 40" AND 60" ABOVE FINISHED SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT A PERSON MAY APPROACH WITHIN 3 INCHES OF SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR STANDING WITHIN THE SWING OF THE DOOR. 4. PICTORIAL SYMBOL SIGNS (PICTOGRAMS). PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION OF THE PICTOGRAM SHALL BE A MINIMUM OF 6 INCHES (152 MM) IN HEIGHT. B. WATER CLOSET: FLUSH CONTROLS ARE TO BE OPERABLE BY AN OSCILLATING HANDLE WITH A MINIMUM OPERATING FORCE OF 5 LB/F OR BY A LOW VOLTAGE BUTTON. THE HANDLE OR BUTTON IS TO BE LOCATED ON THE WIDE SIDE SO AS TO BE OPERABLE WITHOUT REQUIRING EXCESSIVE BODY MOVEMENT. C. LAVATORY: PROVIDE A CLEARANCE OF AT LEAST 29 INCHES FROM THE FLOOR TO THE BOTTOM OF THE APRON WITH KNEE CLEARANCE UNDER THE FRONT LIP EXTENDING A MINIMUM OF 30 INCHES WIDE, TO 8 INCHES MINIMUM DEPTH AT THE TOP. PROVIDE FOR THE CLEARANCE AT LEAST 30 INCHES WIDE, TO 9 INCHES ABOVE THE FLOOR AND 17 INCHES DEEP FROM THE FRONT OF THE LAVATORY. PROVIDE A CLEAR FLOOR SPACE 30 INCHES X 48 INCHES IN FRONT OF LAVATORY. THE CLEAR SPACE MAY EXTEND INTO KNEE AND TOE SPACE UNDERNEATH THE LAVATORY, INSULATE HOT WATER AND DRAIN PIPES UNDER LAVATORIES. NO SHARP OR ABRASIVE SURFACES ARE ALLOWED UNDER LAVATORIES. FAUCET CONTROLS ARE REQUIRED TO BE OPERABLE WITH ONE HAND AND CANNOT REQUIRE GRASPING, PINCHING, OR TWISTING OF THE WRIST, THE FORCE NECESSARY TO OPERATE CONTROLS IS NOT TO EXCEED 5 LB/F. D. ACCESSORIES: WHERE TOWEL, SANITARY NAPKIN AND WASTE RECEPTACLES AND SIMILAR DISPENSING AND DISPOSAL FIXTURES ARE PROVIDED, AT LEAST ONE OF EACH TYPE IS TO BE LOCATED WITH ALL OPERABLE PARTS, INCLUDING COIN SLOTS, WITHIN 40 INCHES FROM THE FLOOR. MOUNT MIRRORS WITH THE BOTTOM EDGE NO MORE THAN 40 INCHES FROM THE FLOOR. LOCATE TOILET TISSUE DISPENSERS ON THE WALL WITHIN 7" MIN TO 9" MAX. FROM THE FRONT EDGE OF THE TOILET SEAT. E. THE STRUCTURAL STRENGTH OF GRAB BARS, FASTENERS, AND MOUNTING DEVICES SHALL MEET THE SPECIFICATIONS OF THE AMERICAN DISABILITIES ACT. F. SINGLE ACCOMMODATION: A CLEAR FLOOR SPACE OF AT LEAST 60 INCHES IN DIAMETER IS REQUIRED FOR SINGLE ACCOMMODATION TOILET ROOMS. TOILET ACCESSORIES 36" BAR MIN: 42" BAR MIN. 60" X 56" MIN CLEAR FLOOR SPACE o 18"� � 1511 MIN.1 MIN. L1728" MI \ 60"MIN. DSA. 12" MI - MI 18" MIN. 30" X 48" MIN. CLEAR FLOOR SPACE SHOWN DASHED PRIVACY LOCK ON DOOR 32" MIN, CLR, 112" CLR. /1–HT-9" ---18" VERTICAL GRAB BAR ----42" GRAB BAR W ROLL PAPER HOLDER o WI I FIOUT STOPS klmT E Y NOTE: THESE FIGURES ARE ILLUSTRATIVE ONLY AND DO NOT DELINEATE THE ONLY MEANS OF COMPLIANCE. REFER TO PLANS FOR EXACT LAYOUT OF TOILET ROOM SUNOBSTRUCTED FORWARD/SIDE REACH A. GEOMETRICAL SYMBOLS 1. WHERE A FORWARD REACH IS UNOBSTRUCTED, THE HIGH FORWARD REACH SHALL BE 48 INCHES MAX. AND THE LOW FORWARD REACH SHALL BE 15 INCHES MIN. ABOVE THE FLOOR. 2. WHERE A PARALLEL APPROACH TO AN ELEMENT AND THE SIDE REACH IS UNOBSTRUCTED, THE HIGH SIDE REACH SHALL BE 48 INCHES MAX. AND THE LOW SIDE REACH SHALL BE 15 INCHES MIN. ABOVE THE FLOOR. 2A. EXCEPTION: EXISTING ELEMENTS SHALL BE PERMITTED AT 54 INCHES MAX. ABOVE THE FLOOR. z � Z Z 4MAX, SIDE FORWARD 11 ACCESSABILE CASH WRAP 0 m 8'- 0" LENGTH NO TUE-KICK BELOW SINK CABINET FOR WHEELCHAIR ACCESSIBILITY 12 ACCESSIBLE DRESSING ROOM a co 0 60 DRESS ROOM MIRROR 33"WX60"L MOUNT '18" A.F.F. ('.I IRTAIIV .1 60" X 36" 'T' I ",—,SHAPED CLEAR AREA CURTAIN MIRROR 33"WX60"L MOUNT 18" A.F.F. -- ACCESSIIB� z w DRESS] O T S W 0r_'1 IPTAINI J ¢Q DRESSING ROOM IS A PRE MANUFACTURED NON -LOAD BEARING DRESSING AREA FURNISHED BY OWNER INSTALLED BY G.C. C� T-0" A.F.F. OPENING @ T-0" A.F.F. .F. IWIPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPAHTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #B11C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 0 2D13 REVISIONS FIN DRAWING NUMBER COBE COMPLIANCE 12 11 i..... � r, f.Yj i �. �. ri, >. •.,ie•...� , .'�. i... � :�,. ', .... .. .,. ..., i. ...3. .. r ,,... e :.,e .., s ... .. .,. .., ... .. .,,. ., . ,,... ,.., ... .. ., ISSUE DATESNX " j PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS FIN DRAWING NUMBER COBE COMPLIANCE 12 11 i..... � r, f.Yj i �. �. ri, >. •.,ie•...� , .'�. i... � :�,. ', .... .. .,. ..., i. ...3. .. r ,,... e :.,e .., s ... .. .,. .., ... .. .,,. ., . ,,... ,.., ... .. ., DEMO GENERAL NOTES GENERAL CONTRACTOR SHALL PROVIDE ALL DEMOLITION AS REQUIRED FOR THE CONSTRUCTION OF THE SPACES DETAILED IN THE ARCHITECTURAL PLANS. ENTIRE SCOPE OF DEMOLITION WORK IS NOT NECESSARILY INDICATED IN THESE DRAWINGS. GENERAL CONTRACTOR SHALL VISIT THE JOBSITE TO DETERMINE QUANTITY OF MATERIALS AND COMPONENTS TO BE REMOVED TO CONSTRUCT THE PROJECT. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING CONDITIONS SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE CONSTRUCTION MANAGER. GENERAL CONTRACTOR TO COORDINATE A PRE -CONSTRUCTION MEETING WITH ON-SITE MANAGEMENT PRIOR TO BEGINNING ANY WORK. REMOVE ALL DEBRIS ON A DAILY BASIS TO GENERAL CONTRACTOR PROVIDED CONTAINERS IN DESIGNATED AREAS. COORDINATE WITH LANDLORD'S SITE MANAGEMENT. DEMOLITION OF ITEMS SHALL INCLUDE COMPLETE REMOVAL OF ANY ASSOCIATED ELECTRICAL, MECHANICAL, OR PLUMBING COMPONENTS. ABANDONED FLOOR PENETRATIONS SHALL BE PROPERLY SEALED IN ACCORDANCE WITH LANDLORD REQUIREMENTS PRIOR TO INSTALLATION OF NEW FLOORING, MATERIALS. COORDINATE ALL WORK IN DEMISING WALLS, ON ROOFS AND IN FLOORS WITH THE LANDLORD. THE FIRE RATING AND STRUCTURAL INTEGRITY OF EXISTING FLOORS, DEMISING WALLS AND COLUMNS SHALL BE MAINTAINED DURING DEMOLITION. CONTRACTOR TO PATCH AND REPAIR THESE ASSEMBLIES AS REQUIRED. COORDINATE WITH THE LANDLORD. VERIFY THE SCOPE OF DEMOLITION WORK TO DETERMINE IF ANY EXISTING EQUIPMENT IS TO REMAIN. SPRINKLER CONTRACTOR TO RELOCATE AND/OR PROVIDE NEW SPRINKLER HEADS AS REQUIRED AND SO AS NOT TO INTERFERE WITH LIGHTING FIXTURES, FIVAC, GRILLES, ETC. SEE ELECTRICAL SHEETS. ALL WORK TO CONFORM TO LOCAL AND N.F.P.A. CODES. CENTER HEADS IN CEILING TILE. NOTIFY MALL MANAGER BEFORE ANY SHUT-OFF. WHEN DOING DEMOLITION: NOTHING TO BE REUSED CAN BE ABANDONED. ALL UNUSED ITEMS (INCLUDING BUT NOT LIMITED TO CONDUITS, PIPING, WIRING, EQUIPMENT, HANGERS, DUCTWORK, ETC.) MUST BE REMOVED TO ITS POINT OF ORIGIN AND SPACE BROUGHT BACK TO ITS ORIGINAL CONDITION. DEMO LL NOTES COORDINATE ALL DEMO WITH LANDLORD PRIOR TO WORK COMMENCING. NOTIFY LANDLORD PRIOR TO DISPOSING OF FLOORING AND TRIM MATERIALS. ANY EXISTING EQUIPMENT OR COMPONENT IN OR PERTAINING TO THE PREMISES THAT IS BEING ABANDONED MUST BE DEMOLISHED COMPLETELY AND PROPERLY REMOVED FROM PREMISES. NO UTILITIES SHALL BE ABANDONED. ALL NON -UTILIZED LINES/RUNS SHALL BE REMOVED BACK TO THE POINT OF ORIGIN. ALL ABOVE GROUND UTILITY LINES NOT TO BE RE -USED MUST BE REMOVED TO POINT OF ORIGIN. ALL UNDER SLAB UTILITY LINES TO BE CUT, CAPPED, AND SEALED PER CODE. ALL ROOF MOUNTED EQUIPMENT ABOVE THE LEASED PREMISES NOT TO BE REUSED MUST BE REMOVED BY TENANT GC AT TENANT EXPENSE. ROOF MUST BE PROPERLY PATCHED BY MALL REQUIRED ROOFER. ROOF CURBS MUST BE REMOVED AND ROOF PATCHED - DO NOT CAP. COORDINATE ALL WORK WITH MALL OPERATIONS DIRECTOR. COORDINATION OF CONSTRUCTION BARRICADE AND DUMPSTERS IS TO BE COORDINATED WITH MALL MANAGEMENT ON SITE. FLOOR PENETRATIONS: TENANT'S GC MUST ADVISE THE PROPERTY'S OPERATIONS DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE CORE -BORED OR SAW -CUT (NO JACK -HAMMERING IS PERMITTED). PRIOR TO WORK, TENANT'S GC MUST VERIFY THAT TENANT'S WORK WILL NOT CONFLICT WITH EXISTING STRUCTURAL, UTILITY, OR OTHER UNDER -SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANT'S EXPENSE. DEMO KEYNOTES �1 REMOVE EXISTING FLOOR FINISHES IN THIS AREA INCLUDING ADHESIVES, GROUT, TRANSITIONS, ETC. DOWN TO CONCRETE SLAB. PREPARE FLOOR SLAB TO MEET NEW FLOOR COVERING MANUFACTURER'S RECOMMENDATIONS AND INFORMATION IN THESE DRAWINGS OREMOVE EXISTING BASE MATERIALS THROUGHOUT. OEXISTING DEMISING WALL. PATCH & REPAIR AS REQUIRED FOR NEW FINISHES. MAINTAIN EXISTING FIRE RATINGS. LEASE LINE. REMOVE EXISTING CEILING IN ITS ENTIRETY. OEXISTING CABINETS/FURNITURE TO BE REMOVED. PATCH & REPAIR AS REQUIRED FOR APPLICATION OF NEW FINISHES. El REMOVE RECEPTACLES, SWITCHES, CONDUITS, ETC., BACK TO THE NEXT POINT OF USE WH'CFI ARE NOT TO BE REUSED AND RELOCATED AND ARE WITHIN WALLS TO BE DEMOLISHED. ® DEMO EXISTING LIGHT FIXTURES (LAY -IN, RECESSED AND SURFACE MOUNTED), LIGHTING TRACKS AND TRACK HEADS, AND RELATED UNUSED CONDUIT AND CONDUCTORS BACK TO THE NEXT POINT OF USE. VERIFY WITH A2 ANY FIXTURES TO REMAIN. `CJ EXISTING EMERGENCY LIGHTING PACKS (CEILING AND WALL MOUNTED) TO BE REPLACED. REFER TO ELECTRICAL PLANS (�4 REMOVE UNUSED CONDUIT AND CONDUCTORS IN WALLS, ON WALLS, AND IN CEILING CAVITIES. M1 EXISTING HEATING AND COOLING UNITS TO BE REMOVED AND REPLACED WITH NEW EQUIPMENT. REFER TO MECHANICAL PLANS. eEXISTING MECHANICAL DUCT TO BE REMOVED. DEMOLITION PLAN 1 1 /4" = V-0" ADJACENT TENANT IWPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.6 34.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FL 32771 DRAWN BY: /SM WD PROJECT NUMBER FRCC00050 NOV& 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 El PERMIT SET: 11-20-2013 REVISIONS ID DRAWING NUMBER DEMO PLAN . ,r . , ., '. ,,., ,.. .. x,.r GI •,,, , .',,. ,.� ter ,.. r .., n. ,.. ter e. ,r 5. .( ..i ".• r,4.a'.'1; 1'u Jrf ir,•i,:r1 ! -. ... 3 :.' T.. <+,`.;I JS. r,l •..r l.i 'v.i ,.,: „ (f.Y. )}.JI^,., 4 ..� !i lJ ! r �: lY l..li x, r,,.i .,, t'•' '. •,Ji �x...',e ::, w.v.,"s, ,y :v ,,.. :..: r ,., i ... .., ,... .,•. .... .. ... ., .., e Yr4 ., ,.. :., FINISH LEGEND - COASTAL MARK DESCRIPTION GENERAL LOCATION VALSPAR SALES AREA WALLS CLR: SEA SALT BLUE #: CI 191 SATIN VALSPAR SERVICE ENTRANCE-/ PT -2 CLR: SAWYER WHITE RESTROOM #: 1002-16 INTERIOR SEMI -GLOSS z VALSPAR SALES AREA CEILING CLR: CREME FRAICHE a_ ff: CI 200 BEHR STOCK ROOM DOOR/ CLR: SEASIDESAND WOOD FRAME ff: 740C-1 OIL BASED SEMI -GLOSS OLYMPIC STOREFRONT CLR: HEIRLOOM LACE SYSTEM #: D 10-1 4" VINYL BASE STOCK ROOM/ CLR: BROWN REsTROOM 6 " WOOD BASE SALES (SUPPLIED SUPPLIED BY FRANCESCA'S, INSTALLED BY CI.C. BY FRANCESCA'S) STOREFRONT WALL TILE STOREFRONT 0 SOLI USA - HOSI MOSAIC CE LL CLR: WHITE / MULTI - PATTERN BY OWNER Uj Ir 0 GROUT: POLYBLEND / CUSTOM CLR: #333 ALABASTER 12"x12" VINYL FLOORING STOCK ROOM/ CLR: BEIGE RESTROOM 0 0 KARNDEAN SALES LL VINYL PLANK - HCO3 CLR; DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ d TEGULAR EDGE CLR: WHITE RESTROOM I 0 STOREFRONT NEW GYP. BID. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES, SEE SEC V. ON CODE STUDY FOR MORE DETAILS. NOTE: ALL SIGNAGE SHALL BE SUBMITTED UNDER SEPARATE COVER FOR LANDLORD REVIEW AND APPROVAL. I �y" 1A �A vid RTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCCO0050 NOV 51 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 0 PERMIT SET: 11 -20-2013 REVISIONS F11 DRAWING NUMBER Z't Al STOREFRONT PERSPECTIVE Al . ......... . ... . ... ................. ... . ... ......... DOOR SCHEDULE DESCRIPTION Double Glass Cabinet measuring 2'x6' with an overall height of 100".Lower section has DBL GS 5/8" TYPE "X" GYP VALSPAR 5/8" TYPE "X" GYP DOOR HARDWARE MARK CA -front LOCATION SIZE TYPE CA -back (18") FRAME DOOR DESCRIPTION HARDWARE FIRE RATING A. HARDWARE AS PROVIDED BY ROLLING GRILLE Optional tables measure 3'3"x5'6", which are noted as 3x5 ROLL-UP8'4" X 8'4" U STEEL ALUM. OVERHEAD DOOR SERIES 670 MANUAL 42"R N/A O GRILLE GYP.BD. G.C. TO PATCH A WS FURRED WALLS, < PUSH-UP DOOR OR APPROVED EQUAL A MOISTURE RESISTANT MANUFACTURER WITH U -CHANGE LOCK CYLINDER WITH Two-tiered 4' wood shelves, upper shelf is hung at 76"h, bottom bench is at 18"h & REPAIR AS REQUIRED. C note: 3FO MOISTURE RESISTANT BEHR face -out brackets GYP ON RESTROOM CLR: SEASIDE SAND Stacked shelving for stockroom, 12" deep wall mounted. Shelf with pole @5'3 & Top shelf THUMBTURN ON STORE SIDE. GC TO PROVIDE AND INSTALL SIGNAGE ON STORE SIDE OF BOTTOM RAIL OF #: 740C-1 OIL BASED SEMI -GLOSS GYP ON RESTROOM Stk. Shelv. OLYMPIC NEW DESIGN STANDARD - JELDWEN 15 Shelf (1) 24" wide shelf mounted at 60" a.f.f. for loss prevention equipment Q Small microwave & fridge for stockroom STOCK ROOM 3'-0" X 6'-8" X 1 3/8" B Custom built displays for storefront, standard height is 24"aff, 36"d, variable length, 5/AD.1 WD PANEL LITE DOOR. PAINT PT -4. g N/A GRILLE STATING "GRILLE TO REMAIN IN FULL OPEN CLR: BROWN 3 5/8" X 20 GA. Wood Bench for ADA Dressing room, attached to wall, with front legs. ADA Bench METAL STUDS @ QC TEMPERED GLAZING TO BE FROSTED. POSITION DURING STORE HOURS WHEN OCCUPIED BY THE GENERAL PUBLIC." 5/8" WOOD BASE SALES (SUPPLIED 16" O.C. TO DECK16" ®6" SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. RESTROOM O RESTROOM 3'-0" X 6'-8" X1 3/8" C 5/8" 5/AD 1 WD N"l PT -2 C N/A ' SEE SECTION 4/A1.114 0 O GROUT: POLYBLEND / CUSTOM SEE SECTION 3/A1.1 1- C/) CLR: #333 ALABASTER B. DECORATIVE PRIVACY LOCKSET - G.C. SHALL NOT 12"x12" VINYL FLOORING STOCK ROOM/ O VCT -1 CLR: BEIGE RESTROOM INSTALL CLOSER. 0 KARNDEAN SALES LL VP -1 VINYL PLANK - HCO3 CLR: DUSK OAK, RANDOM PATTERN C. PRIVACY LOCKSET - G.C. SHALL NOT INSTALL CLOSER. SALES/ STOCK ROOM/ CLG-1 NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ dj TEGULAR EDGE CLR: WHITE RESTROOM J U STOREFRONT C)� NEW GYP. BD. CEILING CLEAR Of=ETIING WIDTH TENSION —,,,DRNE END ---------------- END - - - PT -4 PT -2 P -2 FROSTED TEMPERED GLAZING ao - i� U - NOTE: DOOR HARDWARE SHALL BE EASY TO GRASP AND SHALL = NOT REQUIRE GRASPING, TIGHT PINCHING, OR TWISTING OF WRIST. ALL DOORS SHALL HAVE LEVER HARDWARE, - - PANIC RELEASES,OR PUSH-PULL PLATES CENTERED A B (� BETWEEN 30-44" A.FF. ALL LOCKING DEVICES MUST MEET ANSI AND TAS STANDARDS. 5/8" GYP. BD. TRIM DBL- 3 5/8" METAL STUDS. 22 GA. TYP. DOOR JAN r - FRT WOOD BLOCKING 5 DOOR HEAD & JAMB DETAIL 3 =1-0 FRAME DOOR 5/8" GYP. BD. DBL. 3 5/8" METAL STUDS. 22 GA. TYP TRIM FRT WOOD BLOCKING DOORJAMB FRAME WALL LEGEND DESCRIPTION Double Glass Cabinet measuring 2'x6' with an overall height of 100".Lower section has DBL GS 5/8" TYPE "X" GYP VALSPAR 5/8" TYPE "X" GYP BD. TO 6" ABOVE CA -front BD. TO 6" ABOVE CA - back CEILING - OMIT GYP. CA -back (18") CEILING -OMIT GYP. BD. Standard wood tables measure 2'9"x5'3", with an overall height of 2'6" T BD. ON ONE SIDE AT Optional tables measure 3'3"x5'6", which are noted as 3x5 EXISTING 5/8" TYPE "X" Rectangle island, measure 72"w x 30"d x 42"h. U ON ONE SIDE AT A 36" round wood tables with drop leaf, 2'6"h 42"R FURRED WALLS, B SQ Square island, measure 25 1/2"w x 25 1/2"d x 36 1/2"h GYP.BD. G.C. TO PATCH Wood shelves, measuring 12"d, available in 4',6',8' lengths WS FURRED WALLS, < Wood shelving is hung in doubles, the lower one at 66"h and upper at 79"h 4WS MOISTURE RESISTANT a. Two-tiered 4' wood shelves, upper shelf is hung at 76"h, bottom bench is at 18"h & REPAIR AS REQUIRED. C note: 3FO MOISTURE RESISTANT BEHR face -out brackets GYP ON RESTROOM CLR: SEASIDE SAND Stacked shelving for stockroom, 12" deep wall mounted. Shelf with pole @5'3 & Top shelf MAINTAIN ALL EXISTING #: 740C-1 OIL BASED SEMI -GLOSS GYP ON RESTROOM Stk. Shelv. OLYMPIC WALLS Shelf (1) 24" wide shelf mounted at 60" a.f.f. for loss prevention equipment FIRE RATINGS. INSTALL Small microwave & fridge for stockroom File WALLS Display Custom built displays for storefront, standard height is 24"aff, 36"d, variable length, 3 5/8" X 20 GA. 4" VINYL BASE Three-piece unit composed of right/left/center, with wood or glass shelves, lights ON TENANT SIDE IF NOT Side units measure 16"d x 35"w x 100"h CLR: BROWN 3 5/8" X 20 GA. Wood Bench for ADA Dressing room, attached to wall, with front legs. ADA Bench METAL STUDS @ QC EXISTING METAL STUDS @ 5/8" WOOD BASE SALES (SUPPLIED 16" O.C. TO DECK16" ®6" SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. (E) 6" METAL 5/8" O.C. TO 8'-6" STOREFRONT WALL TILE STOREFRONT O 5/8" LlSTUD. U- CLR: WHITE / MULTI - PATTERN BY OWNER ' SEE SECTION 4/A1.114 0 O GROUT: POLYBLEND / CUSTOM SEE SECTION 3/A1.1 NEW WALLS DEMISING WALLS USE 20GA. MTL STUDS UNLESS OTHERWISE NOTED J -MOLD ON TOP OF GYP. BD. NEW WALLS @ RESTROOM ° 16 GA. MIN. MTL. TRACK 18 GAUGE CONT DEFLECTION (� TOP AND BUTTON TRACK W/ 1-1/2" MINIMUM _ +8'-6" A.F.F. DEEP LEGS - ATTACHMENT T.O. WALL PER SCHEDULE r 9 FASTEN STUD TO RUNNER W/ (1) #10-16 SCREW PER FLANGE 20 GAUGE CONT 8'-0" A.F.F. I! TRACK TO MATCH B ACT CEIL TO DECK WALL STUD WIDTH SCHEDULED PER t 20 GAUGE CONT. TRACK TO MATCH 3 5/8" MTL. STUDS & GYP. BD. a WALL STUD WIDTH WALL SYSTEM. WALL BASE, SEE FINISH SCHEDULEWALL ANCHOR, SEE 6B/- (1) #10-16 SCREW TRACK ATTACHMENT PER STUD BASE, WHERE OCCURS. SEE PER SCHEDULE FLANGE, TYP. FINISH SCHEDULE NEW CONCRETE jk +0'-0" SLAB BY G.C. FINISH FLOOR A TO SLAB WALL ATTACHMENT DETAIL 3 RESTROOM WALL DETAIL 6O" CLR. 18" 24" MIN 0 36" GRAB BAR - GZ. TO INSTALL 72 BLOCKING IN WALL 1z idab.o d = 5/A4 48" CLR - IOD 7/A4 I 42" GRAB BAR - G.G. TO INSTALL BLOCKING IN WALL. LA Wr= 504 -IMT A4 I ��C FOR IRESTROOM ELEVATIONS I , ll N I h. GEN. NOTES CONSTRUCTION KEYNOTES 1. DIMENSIONS ARE TO FINISH SURFACES UNLESS NOTED ® LEASE LINE. OTHERWISE. O 2. THE G.C. IS RESPONSIBLE FOR CONFIRMING OVERALL EXISTING DEMISING WALL. G.C. TO PATCH & REPAIR AS REQUIRED. DIMENSIONS AND STRUCTURAL CONDITIONS PRIOR TO BEGINNING WORK. ANY DISCREPANCIES O ALL FIXTURES PROVIDED BY MILLWORK VENDOR. OR PROBLEMATIC CONDITIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE G.C.. ALL 3. REPORT ALL SHELL BUILDING DEFECTS "EO "EHE G.C. O BEFORE WALLS RE COVERED FROM FLOOR TO CEILING WITH PAINT. ALL WALLS TO BE BROUGHT TO A LEVEL 3 FINISH G. IMMEDIATELY UPON DISCOVERY. LL GENERAL NOTES T.G.C. IS TO OBTAIN APPROVAL AND REQUIREMENTS FROM ON SITE TENANT COORDINATOR PRIOR TO ANY CUTTING OR DRILLING OF EXISTING FLOOR. TENANT IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS IN THE SPACE. FAILURE TO PROPERLY FIELD VERIFY EXISTING CONDITIONS DOES NOT RELIEVE THE TENANT OF ANY EXPENSES OR RESPONSIBILITIES RESULTING FROM THAT FAILURE. NOTHING IS PERMITTED TO BE ATTACHED TO, BE SUSPENDED FROM, OR PENETRATE THE ROOF DECK. TENANTS MAY ATTACH TO JOIST(S), AT PANEL POINTS, UR TO THE STRUCTURAL STEEL. ALL WALL CONSTRUCTION SHALL BE SUPPORTED IN THIS MANNER. NO WELDING TOR SHOOTING INTO THE STRUCTURE IS PERMITTED. STRUCTURAL REINFORCING DETAILS MUST BE PROVIDED BY A REGISTERED STRUCTURAL ENGINEER TO TENANT COORDINATION FOR EQUIPMENT SUPPORT OR SUSPENSION, SERVICE PLATFORMS, DECK PENETRATIONS, ETC. - FOR LANDLORD'S RECORDS. ANY LANDLORD EQUIPMENT OR COMPONENT THAT IS EXISTING IN THE SPACE MUSE REMAIN VISIBLE AND ACCESSIBLE TO THE LANDLORD. TENANT TO INSTALL ACCESS PANELS AS NECESSARY, AND PROPERLY LABEL IN SPACE. COORDINATE PLACEMENT WITH MALL OPERATIONS DIRECTOR. TENANT'S STOCKROOM MAY NOT BE VISIBLE FROM THE SALES AREA. DOOR(S) LEADING TO THE STOCKROOM MUST HAVE AN AUTOMATIC CLOSURE. ALL CONCRETE PATCHING MUS -T BE LEVEL WITH THE EXISTING CONCRETE FLOOR. ALL FLOORING TRANSITIONS MUST BE SMOOTH & FLUSH. THE USE OF PLASTIC, VINYL, OR RUBBER TRANSITION STRIPS IS STRICTLY PROHIBITED. TENANTS MUST UTILIZE A HARD SURFACE TRANSITION. NO RUBBER OR VINYL BASE IS PERMITTED IN THE SALES AREA OF THE PREMISES Item Description DESCRIPTION Double Glass Cabinet measuring 2'x6' with an overall height of 100".Lower section has DBL GS _ 1 '4"ZZ VALSPAR sliding wood doors with inner shelf. Upper section consists of glass shelves, with lights Front Cashwrap meets ADA requirements with a center drop-down section measuring 36" CA -front wide at a height of 33" aff. Overall dimensions are 96"I x 36" d x overall height of 44". CA - back Back Cashwrap; 8' long version, 2'4"d x 44"h. CA -back (18") OPTIONAL Back Cashwrap; 6' long, 18"d x 44"h Standard wood tables measure 2'9"x5'3", with an overall height of 2'6" T SERVICE ENTRANCE/ Optional tables measure 3'3"x5'6", which are noted as 3x5 IS Rectangle island, measure 72"w x 30"d x 42"h. U 36" round unfinished tables, 2'6"h DL 36" round wood tables with drop leaf, 2'6"h 42"R 42" round wood tiered table SQ Square island, measure 25 1/2"w x 25 1/2"d x 36 1/2"h Z Wood shelves, measuring 12"d, available in 4',6',8' lengths WS SALES AREA CEILING < Wood shelving is hung in doubles, the lower one at 66"h and upper at 79"h 4WS 4' Wood shelf elevation, shelves are hung at 24",40",5611,72" a. Two-tiered 4' wood shelves, upper shelf is hung at 76"h, bottom bench is at 18"h #: CI 200 note: 3FO * There needs to be 3" gaps on either side to allow for the hangers to hang freely on the BEHR face -out brackets * Do not attach the lower bench to the wall CLR: SEASIDE SAND Stacked shelving for stockroom, 12" deep wall mounted. Shelf with pole @5'3 & Top shelf SS #: 740C-1 OIL BASED SEMI -GLOSS at 7' aff, variable lengths Stk. Shelv. OLYMPIC (4) 12" deep wall mounted shelving for stock room spaced equally with top shelf at 7' aff Shelf (1) 24" wide shelf mounted at 60" a.f.f. for loss prevention equipment M/F Small microwave & fridge for stockroom File Small file for stockroom Display Custom built displays for storefront, standard height is 24"aff, 36"d, variable length, finished with trim 4" VINYL BASE Three-piece unit composed of right/left/center, with wood or glass shelves, lights Armoire Side units measure 16"d x 35"w x 100"h CLR: BROWN Center unit measures 20"d x 36"w x 100"h Wood Bench for ADA Dressing room, attached to wall, with front legs. ADA Bench Measuring 42"wx18"hx20"w NOTE: PROVIDE CONCEALED F.R.T. WOOD BLOCKING AT ALL RETAIL FIXTURES ANCHORED TO WALLS. Hi O PREP CONCRETE SLAB FOR INSTALLATION OF NEW FLOOR FINISH PER MANUFACTURERS RECOMMENDATION. ALL FLOORING TRANSITIONS TO BE LEVEL AND FLUSH AND COMPLY WITH ANSI A117.1 & CALIFORNIA BUILDING CODE. O NEW ELECTRICAL PANEL. G.C. TO PULL SERVICE TO SPACE FROM LANDLORDS DESIGNATED LOCATION. SEE ELEC. O NEW INTERIOR WALLS. SEE WALL TYPE SCHEDULE FOR DETAILS. O NEW STOREFRONT SYSTEM. SEE ELEVATIONS FOR MORE INFO. O NEW ADA RESTROOM. SEE DETAIL THIS SHEET AND ELEVATIONS ON A4 FOR MORE INFORMATION. SEE PLUMBING FOR FIXTURE SPECS. 10 APPROXIMATE LOCATION OF FIRE EXTINGUISHER. GC TO COORDINATE WITH FIRE MARSHAL FOR PREFERRED LOCATIONS 11 CUT FLOOR (CORE DRILL ON ELEVATED FLOORS) 6'4" FROM WALL FOR RECEPTACLE & CAT5 FOR CASHWRAP, SEE ELECTRICAL FOR DETAILS. T.G.C. TO OBTAIN L.L. REQUIREMENTS BEFORE CUTTING 1� NEW DEMISING WALL BY LL. G.C. TO INSTALL 5/8" TYPE'X' GYP. BD. ON TENANT SIDE AND PROVIDE BLOCKING AS NECESSARY. 13 MESH WALL GRID BEHIND CASHWRAP. G.C. TO PROVIDE HORIZONTAL BLOCKING @ 24" O.C.-SCREW BOTTOM OF MESH TO MITIGATE MOVEMENT FROM WALL. ADJACENT TENANT a%i'-Q 'd/All FINISH LEGEND - COASTAL NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES. SEE SEC V. ON CODE STUDY FOR MORE DETAILS, T 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T W DPARTN ERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #D11 C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCCO0050 NOV . 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 Q PERMIT SET: 11-20-2013 * MARK DESCRIPTION GENERAL LOCATION 1 1/2- _ 1 '4"ZZ VALSPAR SALES AREA WALLS PT -1 CLR: SEA SALT BLUE #: CI 191 SATIN .. )...:)% -... .., .'..,....r.. ., ,<..,, ,,,. :. ✓.,; ..':.ry:rt,. .,J i,! i wM1 .,if ,..i �, r.':,.l i., .:I:. ,., f' ,..: i..4 rl Y.r � i,f r✓w��wr«,.. r)�,.r .r.f,r 4, 1. : i✓., s., Citi': lel er riX.. t.i. ', 1J.1'� ,Y .. '.� �i .. !: '..! VALSPAR SERVICE ENTRANCE/ PT -2 CLR: SAWYER WHITE RESTROOM #: 7002-16 INTERIOR SEMI -GLOSS Z VALSPAR SALES AREA CEILING < PT -3 CLR: CREME FRAICHE a. #: CI 200 BEHR STOCK ROOM DOOR/ PT -4 CLR: SEASIDE SAND WOOD FRAME #: 740C-1 OIL BASED SEMI -GLOSS OLYMPIC STOREFRONT PT -5 CLR: HEIRLOOM LACE SYSTEM #: D10-1 4" VINYL BASE STOCK ROOM/ B-1 CLR: BROWN RESTROOM QC WOOD BASE SALES (SUPPLIED ®6" SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. BY FRANCESCA'S) STOREFRONT WALL TILE STOREFRONT O WT -1 SOLI USA - HOSI MOSAIC U- CLR: WHITE / MULTI - PATTERN BY OWNER 0 O GROUT: POLYBLEND / CUSTOM 1- C/) CLR: #333 ALABASTER 12"x12" VINYL FLOORING STOCK ROOM/ O VCT -1 CLR: BEIGE RESTROOM 0 KARNDEAN SALES LL VP -1 VINYL PLANK - HCO3 CLR: DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ CLG-1 NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ dj TEGULAR EDGE CLR: WHITE RESTROOM J U STOREFRONT C)� NEW GYP. BD. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES. SEE SEC V. ON CODE STUDY FOR MORE DETAILS, T 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T W DPARTN ERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #D11 C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCCO0050 NOV . 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 Q PERMIT SET: 11-20-2013 * 3"= V-0" 1 1/2- _ 1 '4"ZZ : .. )...:)% -... .., .'..,....r.. ., ,<..,, ,,,. :. ✓.,; ..':.ry:rt,. .,J i,! i wM1 .,if ,..i �, r.':,.l i., .:I:. ,., f' ,..: i..4 rl Y.r � i,f r✓w��wr«,.. r)�,.r .r.f,r 4, 1. : i✓., s., Citi': lel er riX.. t.i. ', 1J.1'� ,Y .. '.� �i .. !: '..! FINISH LEGEND - COASTAL COMMENTS MARK DESCRIPTION GENERAL LOCATION REFER TO SHEET E2 FOR SURFACE MOUNT VALSPAR SALES AREA WALLS REFER TO SHEET E2 FOR PT 1 CLR: SEA SALT BLUE DISPLAY AREA IF: Cl 191 SATIN FOR EMERGENCY FIXTURES ENTRY/ VALSPAR SERVICE ENTRANCE/ REFER TO SHEET E2 FOR PT -2 CLR: SAWYER WHITE RESTROOM #: 7002-16 INTERIOR SEMI -GLOSS REFER TO SHEET E2 FOR c@ 90" A.F.F. F -- z SALES- VALSPAR SALES AREA CEILING a.( PT 3 CLR: CREME FRAICHE LL. #:C1200 BEHR STOCK ROOM DOOR/ PT 4 CLR: SEASIDE SAND WOOD FRAME #: 7400-1 OIL BASED SEMI -GLOSS OLYMPIC; STOREFRONT PT -5 CLR: HEIRLOOM LACE SYSTEM #: D10-1 STOCK ROOM/ B-1 4" VINYL BASE RESTROOM CLR: BROWN 6" WOOD BASE SALES (SUPPLIED B_z SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. BY FRANCESCA'S) z STOREFRONT WALL TILE STOREFRONT 0 W_i-1 SOLI USA - HOSI MOSAIC CLR: WHITE / MULTI - PATTERN BY OWNER U- w w GROUT: POLYBLEND / CUSTOM CLR: #333 ALABASTER STOCK ROOM/ 12"x12" VINYL FLOORING RESTROOM � VCT -1 CLR: BEIGE O 0 KARNDEAN SALES L VP -1 VINYL PLANK - HCO3 CLR: DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ CLG-1 TEGULAR EDGE CLR: WHITE RESTROOM 0 J STOREFRONT U CLG-2 NEW GYP. BD. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES. SEE SEC V. ON CODE STUDY FOR MORE DETAILS. LIGHTING SCHEDULE MARK DESCRIPTION 0 0 0 o TRACK LIGHTING WHITE TRACK LIGHTING 6" RECESSED CAN 0 LIGHT O CHANDELIER SCONCE 1x4 FLUORESCENT LIGHTING LOCATION COMMENTS SALES AREA REFER TO SHEET E2 FOR SURFACE MOUNT SPECIFICATIONS. REFER TO SHEET E2 FOR STOREFRONT SPECIFICATIONS. DISPLAY AREA FOR EMERGENCY FIXTURES ENTRY/ CONNECT TO INVERTER. SALES AREA REFER TO SHEET E2 FOR SPECIFICATIONS. SALES -CENTER OVER CASH WRAP REFER TO SHEET E2 FOR c@ 90" A.F.F. SPECIFICATIONS. SALES- REFER TO SHEET E2 FOR ABOVE DRESSING SPECIFICATIONS. a 82" A.F.F. REFER TO SHEET E2 FOR STOCK ROOM SPECIFICATIONS. NOTE: INSTALL CHANDELIER ONLY AFTER THE CASHWRAP HAS BEEN PROPERLY POSITIONED. NO EXCEPTIONS, SPRINKLER NOTES 1) SIMON PROPERTY GROUP REQUIRES ALL TENANTS TO USE MALL CONTRACTOR FOR ALL SPRINKLER WORK. 2) AT TIME OF BIDDING, TENANT OR T.G.C. SHOULD CONTACT SIMPLEX GRINNELL'S NATIONAL ACCOUNTS REPRESENTATIVE TO OBTAIN DIRECTION FOR PRICING AND SCHEDULING. 1-800-299-4377, OPTION 4. TENANT OR T.G.C. IS REQUIRED TO CONTRACT WITH AND PAY FOR ALL TENANT SPRINKLER WORK DIRECTLY WITH SIMPLEX GRINNELL. 3) SPRINKLER SYSTEM MUST BE FULLY CHARGED AND OPERATIONAL WHENEVER CONTRACTOR IS NOT ON SITE. 4) ALL SPRINKLER WORK (SHOP DRAWINGS) TO BE APPROVED BY LANDLORD'S INSURER. SUBMIT PLANS TO: GLOBAL RISK CONSULTANTS ATTN: LORI MEYER/ SIMON TENANT PLAN REVIEW 1003 REGENCY MANOR DRIVE BALLWIN, MO 63011 636-891-9052 lori.meyer a globalriskconsultants.com 5) TENANT TO CONTACT MALL OPERATIONS DIRECTOR, DAVID MILLER, AT 407-323-1843 FOR LIST OF MALL APPROVED ROOFING & SPRINKLER CONTRACTORS. 6) FIRE PROTECTION CONTRACTOR IS LIABLE FOR COMPLIANCE WITH ALL NATIONAL, STATE, AND LOCAL FIRE PROTECTION REQUIREMENTS. 7) TENANT'S SPRINKLER SYSTEM SHALL BE TESTED IN ACCORDANCE WITH NFPA 13. 8) UPON COMPLETION OF SPRINKLER SYSTEM MODIFICATIONS AND TESTS, CONTRACTOR SHALL SUBMIT A WRITTEN CERTIFICATE TO THE LANDLORD FOR THE UNDERWRITER STATING THAT THE SYSTEM HAS BEEN HYDROSTATICALLY TESTED, INSPECTED AND APPROVED. 9) ALL SPRINKLER HEADS IN STOREFRONT DISPLAY & ENTRANCES AREAS ARE TO BE FULLY RECESSED WITH FACTORY FINISHED COVER PLATES. SPRINKLER HEADS IN SALES AREA CAN BE FULLY CONCEALED OR SEMI RECESSED PENDANT CHROME HEADS AS A MIN. w MARK 'f� 0 Ell DESCRIPTION EMERGENCY LIGHTING REMOTE HEAD LOCATION COMMENTS THROUGHOUT REFER TO SHEET E2 FOR SPECIFICATIONS. RESTROOM RESTROOM FAN/ I RESTROOM LIGHT EXIT LIGHT THROUGHOUT EDGE LIT C7a SALES COMBO EXIT/STOCK ROOM EMERGENCY LIGHT REFER TO SHEET E2 FOR SPECIFICATIONS. REFER TO SHEET M1 FOR SPECIFICATIONS. EXISTING TO REMAIN. REFER TO SHEET E2 FOR SPECIFICATIONS. -REFER TO SHEET E2 FOR SPECIFICATIONS. CEILING KEYNOTES 0 G.C. TO INSTALL J -BOX CENTERED EQUALLY OVER CASH COUNTER FOR INSTALLATION OF CHANDELIER. 2 NEW TRACK LIGHTS MOUNTED TO CEILING. 3 NEW RECESSED LED CAN LIGHTS FOR EMERGENCY LIGHTING, TYP. 4 NEW WALL MOUNTED FITTING ROOM SCONCE FIXTURES CENTERED OVER MIRROR 18 5 NEW EMERGENCY EGRESS / EXIT LIGHTS. REFER TO ELECTRICAL 6 NEW CEILING MOUNTED STOCKROOM LIGHTS, TYP. 7 NEW CEILING MOUNTED RESTROOM LIGHTING. NEW FAN/LIGHT COMBO IN RESTROOM. CEILING NOTES VERIFY HEIGHT OF EXISTING DUCT WORK. ALL SUPPORTS ARE ATTACHED FROM THE STRUCTURAL JOISTS & BEAMS ABOVE. DO NOT ATTACH TO DECK. ONLY THE CEILING SHALL BE SUSPENDED FROM THE STRUCTURE ABOVE. ANY ITEM TO BE SUSPENDED FROM THE STRUCTURE MUST RECEIVE PRIOR WRITTEN APPROVAL BY THE LANDLORD. COORDINATE ALL CEILING WORK WITH THE LANDLORD PRIOR TO COMMENCING. ADJACENT TENANT '6 , 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FL 32771 DRAWN BY: /SM WD PROJECT NUMBER FRCC00050 livY ;I V L.U1J s llll ISSUE DATES [] PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 j PERMIT SET: 11-20-2013 REVISIONS 0 DRAWING NUMBER REFLECTED CEILING PLAN I 1/411 = 1'-0" ., ..x Y .. ,.. a... a , .... - z ,., r ., ., � , n r Y r r na .. .. .. t .. ,.,,,, ,, ,.e'- x....a.. ,.: ,,, ..�,. ,, ,, ,.,.'z ., .>�.,x..,,. ..,,,s:i ..x .., ..i .x ..... ,.,� •,,.,.,:: .. ... ..:. .. .. .... ,.,. ...., ,,,.,,., .x,s 3: e, ......,. u „x. �,.,., ,,,.,,, s. ,, .., ... ... .. ...... .. � ...•...., .. ,. .,. .., .. .,., r w u w r Ywr r ELEVATION LWOLDE® n STOREFRONT ELEVATION (FRONT) 3/4" = V-0" 12'-10" A.F.F. T.O. BULKHEAD 11'-0" A. F. F. AN T.O. GLAZING 8'-0" A.F.F. T.O. GRILLE 0'-0" A.F.F. T.O. SLAB is MR PARTNERS brand : operations : build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T W DPARTN ERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#13111C SANFORD, EL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 NOV 2 0 2013 ISSUE DATES 0 PRELIM SET: 10-16-2013 0 FINAL SET: 11-6-2013 0 PERMIT SET: 11-20-2013 REVISIONS 0 DRAWING NUMBER STOREFRONT KEYNOTES OLEASE LINE, TYP. 0 EXISTING MALL BULKHEAD TO REMAIN. ONEW STYLMARK WALLMAKER ANODIZED ALUMINUM STOREFRONT SYSTEM, PAINTED PT -5, W/ 1/2" TEMPERED GLAZING. 0 SIGN LEDGE W/ LED COVE LIGHTING. BREAK METAL (MT -1) OVER 5/8" FRT PLYWOOD ON 2 1/2" METAL STUDS. SIGNAGE BY VENDOR. ONEW 3"H VINYL SAFETY GRAPHICS APPLIED TO INSIDE OF GLAZING, CENTERED IN GLAZING. 0 WALL TILE (WT -1) FRANCESCA'S WILL PROVIDE TILES AND SHIP TO SITE. OBREAK METAL WRAPPED STUD POSTS. PAINT PT -5 0 WOOD TRIM (POPLAR) TO BE PAINTED PT -5 0 GYP. BD. SOFFIT. PAINT PT -5 FINISH LEGEND - COASTAL MARK DESCRIPTION GENERAL LOCATION VALSPAR SALES AREA WALLS PT -1 CLR: SEA SALT BLUE #: CI 191 SATIN VALSPAR SERVICE ENTRANCE/ PT -2 CLR: SAWYER WHITE RESTROOM #: 7002-16 INTERIOR SEMI -GLOSS F-- VALSPAR SALES AREA CEILING CLR: CREME FRAICHE #:01200 BEHR STOCK ROOM DOOR/ PT 4 CLR: SEASIDE SAND WOOD FRAME #: 740C-1 OIL BASED SEMI -GLOSS OLYMPIC STOREFRONT PT -5 CLR: HEIRLOOM LACE SYSTEM #: D10-1 4" VINYL BASE STOCK ROOM/ B-1 CLR: BROWN RESTROOM CL 6" WOOD BASE SALES (SUPPLIED SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. BY FRANCESCA'S) STOREFRONT WALL TILE STOREFRONT O WT -1 SOLI USA - HOSI MOSAIC °C CLR: WHITE / MULTI - PATTERN BY OWNER Lu 0 U GROUT: POLYBLEND / CUSTOM U) CLR: #333 ALABASTER 12"x12" VINYL FLOORING STOCK ROOM/ VCT -1 CLR: BEIGE RESTROOM O 0 KARNDEAN SALES LL VP -1 VINYL PLANK - HCO3 CLR: DUSK OAK CLG-1 NEW 2x2 ACOUSTICAL TILE CEILING SALES/ STOCK ROOM/ DRESSING ROOM/ TEOULAR EDGE CLR: WHITE RESTROOM J U STOREFRONT CLG-2 NEW GYP. BD. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES. SEE SEC V. ON CODE STUDY FOR MORE DETAILS. LL STOREFRONT NOTES 1) IF NOT ALREADY EXISTING, TENANT MUST PROVIDE A SEALED PARTITION ABOVE THE STOREFRONT TO SEPARATE THE COMMON AREA CEILING FROM THE TENANT'S SPACE. (SHALL BE RATED IF REQUIRED BY CODE.) 2) STOREFRONT GRILLES ARE EXPRESSLY PROHIBITED BY THE LANDLORD. IF EXISTING IN THE SPACE FROM A PRIOR OCCUPANT, TENANT SHALL BE REQUIRED TO REMOVE AS PART OF DEMOLITION. NO EXCEPTIONS WILL BE PERMITTED. 3) SLAT WALL MAY NOT BE USED WITHIN THE FIRST 5'-0" OF THE SPACE. 4) VERTICAL GLASS JOINTS SHALL BE FRAMELESS BUTT JOINTS. 5) PAINTED DRYWALL IS NOT AN ACCEPTABLE STOREFRONT FINISH. 6) ANY DAMAGE TO MALL PROPERTY OR ADJACENT TENANTS DURING CONSTRUCTION MUST BE REPAIRED TO MALL SPECIFICATIONS AT TENANT'S EXPENSE. 7) STOREFRONT SIGN MUST BE ON A 7 -DAY, 24-HOUR TIME CLOCK. ILLUMINATED SIGNS MUST REMAIN ILLUMINATED DURING ALL MALL HOURS. 8) APPROVAL OF THE TENANT'S DESIGN OR WORKING DRAWINGS BY THE LANDLORD SHALL NOT CONSTITUTE REVIEW AND APPROVAL OF THE TENANT'S SIGNAGE. SIGN SHOP DRAWINGS MUST BE SUBMITTED SEPARATELY BY THE TENANT FOR LANDLORD REVIEW AND APPROVAL PRIOR TO FABRICATION AND INSTALLATION OF THE SIGN. is MR PARTNERS brand : operations : build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T W DPARTN ERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#13111C SANFORD, EL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 NOV 2 0 2013 ISSUE DATES 0 PRELIM SET: 10-16-2013 0 FINAL SET: 11-6-2013 0 PERMIT SET: 11-20-2013 REVISIONS 0 DRAWING NUMBER 016 B.O. MALL Bl EL = 12'-10” 5/8" GYP. BD, OVEF G" METAL STUD FRAYING, PAINT PT OgL T.O. STOREFR EL = 11'-0" BOX BEAN HEADER: HITH GOOT125-33 TRS ATTACH TRACK HI -IT @ 12" O.C. EACH FLAI BOX BEANS HITH ON STUD 6005162-33 AN STUD 6005162-33 TY ALUM. STOREFRONT SYSTEM HITH 1/2" TENPERED GLAZING „,,.v ....,.... „ ,,..., ,, .,, ,,. .,, .�, a, v,,.w ., .....,tea , w.,r ,..,., ,,.,.,x ,.,,.,,,v, r x ., �.� n i i. r . ..� .� rY ....w. .. www....+.., r..n. ,...,, n. •. wr. ...w.x .w r.. ,.. . .,, ..... r. ,.. .. ..r ... ,,, .rxw ......,. w.www.aw � .w.wrr rx Y r xs, t s , ,. , .. , , , . ,... ....... ..i . ...... ... ., . , , .a .'ri GID CEILING ' CLG. WIRE @ 6 TYP. B.O. ENTRY EL = 8'-0" '. BD. OVER 1ETAL STUD @ 16" O.C., NALL BUILKHEAC 5/8" GYP. BD. G G" METAL STUD FRAMING, PAINT PT -5 BOX BEAN HEAL HITH GOOT125-3? ATTACH -TRACK @ 12" O.C. EACH BOX BEANS HITT STUD 6005162-3'. STUD 5005162-3 5/8" GYP. BD. G 6" METAL STUD FRAMING, PAINT PT -5 WALL TILE (WT -1) 1/2" CEMENT �304I METAL STUD FR COVE LIGHTING, SPECIFIED BY H. EDGE MOUNTED SIGN BY SIGN VENDOR BOX BEAM HEAD 6005162--33 WITH TRACKS T4B. A'I HITH 410-16 SIRE EACH FLANGE. S BEAMS HITH ONI STUD 3525162--3: BEDDING STUD TYP. EACH END MANUAL ROLL -U SEE AI.I FOR MC NG RIGID CEILING "H 412 CLG. WIRE @ O.C. ) 410-16 `EHS, TYP. B.O. ENTRY EL = 8'-0" 11L AL PARTNERS In wm brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNER S.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #1311 C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 NOV 9 0 2013 ISSUE DATES 0 PRELIM SET: 10-16-2013 0 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS 0 DRAWING NUMBER G.G. IS TO SET CASH WRAP FIXTURE OVER (2) 1/4"D ANCHOR PINS INTO CONCRETE SLAB TO PREVENT THE FIXTURE FROM SLIDING OUT OF POSITION. BORE FIXTURE FEET TO ACCEPT ANCHOR. NOTE: FOOT IS DESIGNED TO BE SCREWED INTO FIXTURE. 0 CASHWRAP PIN DETAIL 1" = 1'-01, BENCH DETAIL NOT TO SCALE w ......_. .... .. ,..:,... r , . ,,:,.::. •., .. ,:..e. „ mii, as �„ w„+:.•. ,. „, DSALES WALL ELEVATION 3/8" = V-0" 10'-6" A. F. F. J B.O. CEILINGY 8'-0" �A.F.Fj4 B.O. SOFFIT Y 0'-0" A.F.F. T.O. SLAB 3 �V Y Y, 1#,L LLL Y I % 1 1 yr m 3/8" = 1'-0" 2' X 3' MIRROR - INSTALL MIRROR DIRECT TO GiYP. E3D. — T-0" Ole 12" 2'-0" LU A Q 10'-6" A.F.F. B.O. CEILING A. 0'-0" A.F�F.A T.O. SLAB V NOTE TO G.C.: ALL SHELVES WITH A CLOTHING ROD MUST BE SUPPORTED ONLY WITH BRACKETS PROVIDING HANG BAR SUPPORT FINISH LEGEND - COASTAL 6' -WS T FO Ll �\ 61 GENERAL LOCATION W e VALSPAR SALES AREA WALLS PT -1 10'-6" A.F.F. B.O. CEILING A. 0'-0" A.F�F.A T.O. SLAB V NOTE TO G.C.: ALL SHELVES WITH A CLOTHING ROD MUST BE SUPPORTED ONLY WITH BRACKETS PROVIDING HANG BAR SUPPORT FINISH LEGEND - COASTAL 6' -WS T FO Ll MARK DESCRIPTION GENERAL LOCATION 4" VINYL WS 8' -WS 6' -WS VALSPAR SALES AREA WALLS PT -1 CLR: SEA SALT BLUE WATER AND DRAIN WATER AND DRAIN BA5E #: CI 191 SATIN c3It VALSPAR SERVICE ENTRANCE/ PT -2 CLR: SAWYER WHITE RESTROOM RESTROOM ELEVATION #: 7002-16 INTERIOR SEMI -GLOSS 5 3/8 = 1 -0 6 -3/8'- V-0" Z I VALSPAR SALES AREA CEILING r..r-]:., '. .., :r{,' ', ,.:: .d, !'f.,.,,,. •, � �. •t-, ,,... :,, ,. ,.t r..� II t, r' .4r a a .i ..::•..; ,+, t ..: ... v. rv.. ';...ii CLR: CREME FRAICHE LL #: CI 200 BEHR STOCK ROOM DOOR/ PT 4 CLR: SEASIDE SAND WOOD FRAME #: 740C-1 OIL BASED SEMI -GLOSS OLYMPIC STOREFRONT PT -5 CLR: HEIRLOOM LACE SYSTEM #: D.10-1 4" VINYL BASE STOCK ROOM/ B 1 CLR: BROWN RESTROOM WOOD BASE SALES (SUPPLIED ®6" B z SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. BY FRANCESCA'S) STOREFRONT WALL TILE STOREFRONT GO WTI SOLI USA - HOSI MOSAIC m CLR: WHITE / MULTI - PATTERN BY OWNER U_ W 0 0 GROUT: POLYBLEND / CUSTOM F- CLR: #333 ALABASTER STOCK ROOM/ 1211x121' VINYL FLOORING RESTROOM cc VCT -1 CLR: BEIGE O O KARNDEAN SALES LL VP 1 VINYL PLANK - HCO3 CLR: DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ CLG-1 TEGULAR EDGE CLR: WHITE RESTROOM � U STOREFRONT CLG 2 NEW GYP. BD. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES. SEE SEC V. ON CODE STUDY FOR MORE DETAILS. ELEVATION UNFOLDED ENTRY ELEVATION 2 3/8" = 1 '-0" 10'-6" A.F.F. B.O. CEILING 8'-0" A.F.F. B.O. SOFFIT 0'-0" A*F ' F. F. "111,T.O. SLAB CLG-1 PT -3 PT -1 6' -WS T FO Ll L--4" VINYL I�®6�� � -- INSUI-ATE EXP05ED INSULATE EXPOSED 4" VINYL 4" VINYL WS 8' -WS 6' -WS ; -1" 1�11N. t�vjp_jinB-2 SALES WALL ELEVA I ION 4 3/8" = 1'-0" AR 'APER SER 10'-6" A.F.F. B.O. CEILING _ 0'-0" A.F.F. T.O. SLAB IWPARTNERS brand: operations * build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000'r WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #B11C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 NOV-2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS DRAWING NUMBER L--4" VINYL I�®6�� � -- INSUI-ATE EXP05ED INSULATE EXPOSED 4" VINYL 4" VINYL ��+ vuv qgE ; -1" 1�11N. g,gSE WATER AND DRAIN WATER AND DRAIN BA5E 5,45E c3It PIPES PIPES RESTROOM ELEVATION RESTROOM ELEVATION RESTROOM ELEVATION 8 RESTROpOM ELEVATION 5 3/8 = 1 -0 6 -3/8'- V-0" I r..r-]:., '. .., :r{,' ', ,.:: .d, !'f.,.,,,. •, � �. •t-, ,,... :,, ,. ,.t r..� II t, r' .4r a a .i ..::•..; ,+, t ..: ... v. rv.. ';...ii IWPARTNERS brand: operations * build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000'r WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #B11C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 NOV-2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS DRAWING NUMBER VAV BOX SCHEDULE EXHAUST FAN SCHEDULE TAG MANUFACTURER INLET CFMSIZE O.A. TAG MAKE MODEL NO. NOTES Sales NOTES DESCRIPTION 15 CFM CFM HP NOTES MAX MIN EF -1 VAV-1 TRANE VCCF12 12" 1000 300 1,2 NOTES: 1. FACTORY PROVIDED DISCONNECT SWITCH, CONTROL TRANSFORMER. 2. PROVIDE NEW THERMOSTAT. COORDINATE WITH LANDLORD FOR THERMOSTAT MANUFACTURER AND MODEL INFORMATION. VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 EXHAUST FAN SCHEDULE TAG MANUFACTURER MODEL NOMINAL O.A. FAN VOLTAGE MCA/MOCP NOTES Sales "SAG DESCRIPTION 15 CFM CFM HP NOTES MANUFACTURER MODEL EF -1 SEE ELEC. WASTE SEE ELEC. 90 - 130 WATTS 120/1/60 - 1 NOTES: WATER CLOSET AMERICAN CADET 1. CEILING EXHAUST FAN. 90 CFM a 0.375" ESP. FURNISHED WITH FACTORY MOUNTED DISCONNECT AND BACKDRAFT DAMPER. 2" 3/4° CWR VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 PLUMBING FIXTURE SCHEDULE Roorn Name Classification Room Area (sq.ft.) Area OA Rate (cfm/sq.ft.) FIXTURE VALVE/FAUCET People OA Rate (cfm/person) CONNECTIONS Sales Area Sales "SAG DESCRIPTION 15 12 7.5 187 NOTES MANUFACTURER MODEL MANUFACTURER MODEL WASTE VENT CW HW Restroorn 64 - - WC -1 WATER CLOSET AMERICAN CADET Total (square feet) 1 954 4" 2" 3/4° CWR 1, 2, 3 RD RETURN DIFFUSER ADA STANDARD #2467.016, WHITE RESISTOR DC DIRECT CURRENT RG RETURN GRILLE DI DIGITAL INPUT RTU LAV -1 LAVATORY AMERICAN LUCERNE AMERICAN RELIANT 2" 1.1/2" 1/2" 1/2" 4, 5, 10 SD SUPPLY DIFFUSER ADA STANDARD #0355.012, WHITE STANDARD #7385.050 FIRE ALARM CONTROL PANEL SMD SMOKE DETECTOR FCU FAN COIL UNIT SR FD -1 FLOOR DRAIN JAY R. SMITH 2O05A-P050 - - 3" 1-1/2" - - 9 UH FCO FLOOR CLEAN JAY R. SMITH SERIES 4000 TO VOLT FSD FIRE SMOKE DAMPER VA - - 7 VAC VOLT ALTERNATING CURRENT OUT HOT SUITE FLOOR FINISH VARIABLE AIR VOLUME HAC HEATED AIR CURTAIN VD VOLUME DAMPER HOA HAND OFF AUTO WAP EWH-1 POINT -OF -USE CHRONOMITE M -20L/208 - L - WUH 3/8 3/8 6 X TRANSFORMED WATER HEATER MINIMUM OR MODULATING DAMPER XMFR TRANSFORMER MIN MINIMUM WMS WIRE MESH SCREEN NOTES: 1. PROVIDE WITH BEMIS MANUFACTURING MODEL 1955SSC STANDARD WHITE OPEN FRONT SEAT. 2. PRESSURE ASSISTED TANK TYPE. 3. FURNISH RIGHT AND LEFT HAND MODELS AS REQUIRED PER ADA. 4. PROVIDE WITH JAY R. SMITH #0700 FLOOR MOUNT CONCEALED -ARM LAVATORY CARRIER. S. PROVIDE WITH TRUEBRO LAV GUARD. 6. 20 AMPS, 208 VOLT SINGLE PHASE, 4160 WATTS, 57°F TEMPERATURE RISE @ 0.5 GPM. 7. PROVIDE POLISHED NICKEL BRONZE COVER WITH ZARB-1470-A CLEANOUT PLUG. 8. CAST IRON CLEANOUT TEE WITH STAINLESS STEEL ROUND COVER. PLUG TO BE GAS AND WATERTIGHT. 9. PROVIDE FLOOR DRAIN WITH 1/2" TRAP PRIMER AND ACCESS DOOR IN WALL FOR ACCESS. 10. PROVIDE LEONARD 270 THERMOSTATIC MIXING VALVE, ASSE 1017 AND ASSE 1070 RATED. VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 1z:1 Roorn Name Classification Room Area (sq.ft.) Area OA Rate (cfm/sq.ft.) Default Occupancy (4/1000 sq.ft.) Occupancy (#) People OA Rate (cfm/person) Total OA (cfin) Sales Area Sales 804 0.12 15 12 7.5 187 Storage Storage Room 86 0.12 - - - 10 Restroom (1 fixture) Restroorn 64 - - - - - PT Total (square feet) 1 954 2. 1/2" X 1/2" X 1/2" EGGCRATE RETURN AIR GRILLE. RA 197 LANDLORD NOTES I ANY CHANGES AND/ OR UPGRADES TO TENAN'T'S EXISTING MECHANICAL SYSTEMS SHALL COMPLY WITH ALL CODES AND MALL CRITERIA. EXISTING SYSTEMS SHALL POSSESS THE CAPACITY TO HANDLE ANY AND ALL CHANGES IN LOAD. 2. NO PITCH POCKETS ARE PERMITTED ON THE ROOF FOR ANY CONDENSATE DRAINS, REFRIGERANT PIPING, POWER, OR CONTROL WIRING. ALL CONNECTIONS ARE TO BE MADE INSIDE THE EQUIPMENT CURB OR THROUGH PRE -MANUFACTURED PIPING CURB. 3. NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK. YOU MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE TENANT SPACE. 4. ALL PENETRATIONS TO ROOF MUST BE APPROVED BY LANDLORD. ALL RELATED ROOF WORK MUST BE DONE BY THE MALL'S DESIGNATED ROOFING CONTRACTOR AT TENANT'S EXPENSE. COORDINATE ALL WORK WITH PROPERTY MANAGEMENT ON SITE. S. TENANT MUST REMOVE ALL ABANDONED ROOFTOP AND/ OR MECHANICAL EQUIPMENT ABOVE THE LEASED PREMISES AND WITHIN THE LEASE PREMISES, AT TENANTS EXPENSE. PATCH AND REPAIR ROOF AS NEEDED. 6. T'ENANT'S GC TO LABEL ALL ROOF TOP EQUIPMENT WITH TENANT NAME SPACE NUMBER AND EQUIPMENT IDENTIFICATION (I.E. RTU -1, EF -1), PER MALL SPECIFICATIONS/ STANDARDS. 7. ALL PIPING_ ON ROOF SHALL BE SUPPORTED ON PRE -MANUFACTURED PIPE SUPPORTS INSTALLED ON CARRY TREAD, SPACED PROPERLY TO SUPPORT PIPING. TREATED WOOD SUPPORTS ARE NOT PERMITTED. 8. ALL UNEXPOSED SUPPLY AIR AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1-1/2" THICK FOIL FACE INSULATION. INTERNALLY LINED DUCTWORK MAY BE USED FOR ACOUSTIC PURPOSES ONLY, NOT AS A SUBSTITUTE FOR EXTERNAL INSULATION. 9. ALL DUCTWORK SHALL BE SHEET METAL. FLEX DUCT MAY ONLY BE USED IN RUNS OF 54" OR LESS. 10. AT CONCLUSION OF PROJECT, HVAC SYSTEM MUST BE TESTED AND BALANCED BY A LICENSED CONTRACTOR, COPY OF BALANCE REPORT MUST BE PROVIDED TO PROPERTY MANAGEMENT OFFICE ON SITE. ,, _z R 0 01 EF -1/7\ 90 - LAV -1 C9A/LJ A / f, DRAWING LEGEND 1z:1 SUPPLY DIFFUSER 0 RETURN GRILLE / REGISTER , TAG MODEL SD -1 AIR DEVICE DESIGNATION 150 TYPE '�F-- CFM AUX AUXILLIARY EXHAUST FAN / LIGHT COMBO Q THERMOSTAT ® SPRINKLER HEAD (E) EXISTING TO REMAIN (R) EXISTING TO BE RELOCATED (N) NEW M101MECHANICAL PLAN ®" SCALE: 1/4"=1'-0" AIR DEVICE SCHEDULE TAG MOUNTING I DESCRIPTION FINISH MANUFACTURER MODEL SIZE NOTES ANALOG OUTPUT TYPE NORMALLY CLOSED AUX AUXILLIARY NO. NORMALLY OPEN AWG SD -1 LAY -IN SUPPLY WHITE TITUS OMNI 24x24 1 RG -1 LAY -IN RETURN WHITE TITUS 5OF 2424 2 NOTES: PT 1. PROVIDE AG -75 DAMPER. CV 2. 1/2" X 1/2" X 1/2" EGGCRATE RETURN AIR GRILLE. AHU AIR HANDLING UNIT MOD MODULATING Al ANALOG INPUT N NEUTRAL AO ANALOG OUTPUT NO NORMALLY CLOSED AUX AUXILLIARY NO NORMALLY OPEN AWG AMERICAN WIRE GAUGE OA OUTDOOR AIR CD CONTROL DAMPER OL OVERLOAD COM COMMON OVR OVERRIDE CU CONDENSING UNIT PC PHOTOCELL CV CONTROL VALVE PT PROGRAMMABLE THERMOSTAT CV VALVE COEFFICIENT RA RETURN AIR CWR CONDENSER WATER RETURN RD RETURN DIFFUSER CWS CONDENSER WATER SUPPLY RES RESISTOR DC DIRECT CURRENT RG RETURN GRILLE DI DIGITAL INPUT RTU ROOFTOP UNIT DO DIGITAL OUTPUT RVR REVERSING VALVE, RELAY EA EXHAUST" AIR S TEMPERATURE SENSOR EF EXHAUST FAN SD SUPPLY DIFFUSER EOL END OF LINE SEF SMOKE EXHAUST FAN FACP FIRE ALARM CONTROL PANEL SMD SMOKE DETECTOR FCU FAN COIL UNIT SR SUPPLY REGISTER FD FIRE DAMPER TC TIME CLOCK FDM FLOW DISPLAY MODULE TDM TEMPERATURE DISPLAY MODULE FM FLOW METER UH UNIT HEATER FPB FAN POWERED BOX V VOLT FSD FIRE SMOKE DAMPER VA VOLT" AMPERE OND GROUND VAC VOLT ALTERNATING CURRENT H HOT VAV VARIABLE AIR VOLUME HAC HEATED AIR CURTAIN VD VOLUME DAMPER HOA HAND OFF AUTO WAP WIRELESS ACCESS POINT HR HEATING RELAY WSHP WATER SOURCE HEAT PUMP L LINE VOLTAGE WUH WALL UNIT HEATER LS LIQUID SENSOR X TRANSFORMED MD MINIMUM OR MODULATING DAMPER XMFR TRANSFORMER MIN MINIMUM WMS WIRE MESH SCREEN d r CHANGES TO THE DESIGN OF ANY SYSTEM IDENTIFIED ON THESE DRAWINGS OR SPECIFICATIONS SHALL BE SUBMITTED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO THE FABRICATION AND INSTALLATION. ANY MODIFICATIONS WITHOUT THE ORIGINATING ENGINEER'S WRITTEN AUTHORIZATION AND APPROVAL SHALL BE THE RESPONSIBILITY, AS WELL AS THE COST TO CORRECT SUCH MODIFICATION, OF THE CONTRACTOR. GENERAL NOT S: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. SUBMISSION OF A BID SERVES AS EVIDENCE THAT THE CONTRACTOR HAS No 43722 VISITED THE SITE AND HAS ACCOUNTED FOR ALL EXISTING CONDITIONS IN THE BID. 2. BEFORE COMMENCING ANY WORK, CONTRACTOR SHALL REVIEW THE MOST RECENT NATIONAL, 2. STATE, AND LOCAL CODE REQUIREMENTS, AND PERFORM THE WORK IN STRICT" ACCORDANCE WITH It STATF rn.92 ('HESE. 3. CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW THE DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. 4. CONTRACTOR SHALL ADHERE TO LANDLORD SPECIFICATIONS AND TENANT DESIGN CRITERIA. 5. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, AND SUPERVISION NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS AS OUTLINED HEREIN. 6. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL VERIFY THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. 7. PROVIDE ALL LOW VOLTAGE CONTROL WIRING FOR THE TEMPERATURE CONTROL SYSTEM. COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR CONTROL SYSTEM CONDUIT AND POWER �5 REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH THE GC FOR ALL TEMPERATURE CONTROL COMPONENTS. 8. THE CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING, AND DUCTWORK, NOT BEING USED OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. COORDINATE REQUIREMENTS WITH GC AND LANDLORD. VERIFY SCOPE OF WORK WITH GC PRIOR TO BID AND INCLUDE ALL COSTS IN BID. 9. PROVIDE IDENTIFICATION FOR EQUIPMENT" LOCATED ON THE ROOF OR OUTSIDE OF THE DEMISED PREMISES. PROVIDE STENCIL WITH A MINIMUM OF 4" HIGH BLACK SPRAY PAINTED LETTERS, INDICATING TENANT'S NAME, HVAC UNIT NUMBER AND SPACE NUMBER. VERIFY ADDITIONAL 0 REQUIREMENTS WITH LANDLORD. 10. ALL RETURN GRILLES IN CONSTRUCTION AREAS MUST BE COVERED WITH FILTER MEDIA WHILE HVAC SYSTEM IS RUNNING. REPLACE FILTER MEDIA WHEN IT GETS DIRTY. 11. CERTIFIED TAB CONTRACTOR TO REBALANCE NEW AND EXISTING AIR DEVICES TO CFM AS DESIGNATED ON PLAN. SPRINKLER GN L NOT 1. FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL No 43722 JURISDICTION. FINAL INSTALLATION MUST COMPLY WITH NFPA 13 AND STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 2. INSTALL SPRINKLER HEADS ABOVE AND BELOW DUCTWORK AND OTHER OBSTRUCTIONS AS It STATF rn.92 REQUIRED BY NFPA 13. COORDINATE INSTALLATION OF HEADS WITH FIVAC CONTRACTOR AND GC. 3. SPRINKLER HEAD LAYOUT IS A SUGGESTED LAYOUT AND/OR A REPRESENTATION OF THE APPROXIMATE LOCATIONS OF EXISTING HEADS. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL PLANS, STRUCTURAL PLANS, HVAC CONTRACTOR, ELECTRICAL CONTRACTOR, AND GC. THE FIRE SPRINKLER CONTRACTOR SHALL INCLUDE IN THE BID AND BE RESPONSIBLE FOR THE EXACT QUANTITY OF SPRINKLER HEADS REQUIRED FOR COVERAGE AND FINAL APPROVAL. KEYED NOTES: 0 CONNECT NEW SANITARY LINE INTO THE EXISTING SANITARY SERVICE. PROVIDE ADDITIONAL CLEANOUTS AS REQUIRED. FIELD VERIFY EXACT LOCATION AND SIZE OF SANITARY LINE AND No 43722 INVERT PRIOR TO BID. THIS CONTRACTOR IS RESPONSIBLE FOR ANY CUTTING AND PATCHING OF THE FLOOR THAT MAY BE REQUIRED AS IT RELATES TO THE PLUMBING SCOPE OF WORK. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL It STATF rn.92 REQUIREMENTS. CONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY G.C. IF TAP IS SMALLER THAN SHOWN. REFER TO WATER RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. COORDINATE BACKFLOW PREVENTER REQUIREMENTS WITH LANDLORD AND LOCAL AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL PURCHASE WATER METER AND REMOTE READER FROM LANDLORD'S TENANT COORDINATOR. INSTALL PER LANDLORD AND LOCAL AUTHORITY'S REQUIREMENTS. PROVIDE NEW THERMOSTAT FOR VAV-1. COORDINATE MAKE AND MODEL NUMBER WITH LANDLORD TO TIE INTO EXISTING MALL DDC SYSTEM. DEMOLISH EXISTING VAV BOX, VERIFY EXACT LOCATION IN THE FIELD. NEW VAV BOX TO BE INSTALLED IN LOCATION SHOWN. INSTALL VAV BOX IN ACCORDANCE WITH THE MANUFACTURER'S GUIDELINES AND MAINTAIN ALL REQUIRED SERVICE CLEARANCES. �5 CONNECT NEW MEDIUM PRESSURE DUCT TO EXISTING; LANDLORD SUPPLY DUCT SYSTEM. VERIFY EXACT LOCATION IN THE FIELD PRIOR TO VAV BOX INSTALLATION. 6 PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE AND FIELD VERIFY THE EXISTING CONDITIONS OF THE SPRINKLER SYSTEM AND DETERMINE EXACT SCOPE/EXTENT OF SPRINKLER MODIFICATIONS WITH LANDLORD AND LOCAL FIRE MARSHAL. INCLUDE ALL COSTS IN BID FOR REQUIRED SPRINKLER MODIFICATIONS. EXISTING SPRINKLER HEADS IN EXISTING CEILINGS CAN BE REUSED WHERE APPROPRIATE. NEW SPRINKLER HEADS SHALL BE INSTALLED IN NEW CEILING_; OR IN OPEN STRUCTURE AREAS (STOCKROOM) AS REQUIRED. PROVIDE NEW SPRINKLER PIPE AS NEEDED. ENSURE PROPER COVERAGE PER NFPA 13. 0 EXISTING RETURN AIR TRANSFER GRILLE THRU DEMISING WALL SHALL BE REUSED. VERIFY EXACT LOCATION IN THE FIELD. VERIFY EXISTING FIRE DAMPER IS IN COMPLETE WORKING ORDER. REPAIR OR REPLACE AS REQUIRED. PROVIDE NEW POINT OF USE ELECTRIC WATER HEATER. INSTALL AND MAKE PIPING CONNECTIONS PER DETAIL M2-01 ON SHEET M2 AND MANUFACTURER INSTALLATION INSTRUCTIONS. 0 NEW CEILING EXHAUST FAN/LIGHT COMBO BY ELECTRICAL CONTRACTOR. FAN CONTROL SHALL BE WIRED THROUGH THE LIGHT SWITCH SERVING THE RESTROOM. COORDINATE INSTALLATION WITH ELECTRICAL CONTRACTOR. EXTEND 6"0 DUCT FROM THE NEW EXHAUST FAN AND CONNECT TO EXISTING MALL EXHAUST SYSTEM. VERIFY EXACT LOCATION IN THE FIELD. 10 EXTEND NEW VENT PIPING TO MALL VENT SYSTEM. VERIFY MALL VENT SYSTEM LOCATION IN THE FIELD PRIOR TO WORK. REFER TO WASTE AND VENT" RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. LANDLORD NOTES: 1. G.C. SHALL VERIFY TRANSFER AIR OPENINGS EXIST AND MEET MALL CRITERIA FOR VAV/HVAC COMPLIANCE. 2. GC. SHALL UTILIZE A LL APPROVED CONTRACTOR FOR ALL INTERFACE CONNECTIONS TO CURRENT MALL JOHNSON EMS SYSTEM. CONTACT MALL OPERATIONS TO VERIFY. 3. EXTERNALLY INSULATED FLEXIBLE DUCT, NOT TO EXCEED 5'-0" IN LENGTH, MAY BE USED FOR VERI-( CAL CONNECTIONS TO SUPPLY DIFFUSERS ONLY. 4. EXTERNAL FOIL WRAP INSULATION IS MANDATORY FOR ALL SUPPLY AIR DUCT WORK IN CLOSED CEILING AREAS AND NOT IN LIEU OF INTERNAL DUCT LINER. LANDLORD NOTES: 1. NO PVC OR PEX ABOVE GRADE. 2. PLUMBING IS NOT PERMITTED IN LANDLORDS DEMISING WALLS. FURR OUT WALLS WHEN NECESSARY. 3. ALL TOILET ROOMS TO HAVE FLOOR DRAINS WITH TRAP PRIMERS. 4. G.C. TO COORDINATE ALL FLOOR CUTS AND CONNECTIONS TO LL WATER AND SANITARY MAINS WITH MALL OPERATIONS. V%d PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #B11C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 R N No 43722 % 0 It STATF rn.92 ; sft A NOV 20 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 Q PERMIT SET: 11-20-2013 REVISIONS 0 DRAWING NUMBER i� i. ,z ,sr, <, , .,x. „� .. > ::. i' 3 ro.x �..�.a .,,.,+.a . ,a.. , ,r x»x. ,� „ r,... . a . . „ar.. , ,,, ,.., ,��r , .. „ .. . ... ... .... .. ., .. ,.. . ; . re r,'.: .,,',:i' r ; r ,;i,;, ,x..x., ,,, ,....w ........ .... .. .^. .,. .. ,,.r, .. a..,. �s r..,r ,. >„, ... .,,, ., a, Vii',. i i I:,. ., .. .nom. .x r ,,,, +. .......... ...... ... , „i .. . .. w..,r d x e... .:: ,I. .. A..,: ,,,.,..„..a .., �,w. .:: ..... .. .. .....::................ .. .. r ....... .....s r..„ ..xi.., .., Y .: r:'... .. . , .... ., ,,, ,... ,.....,...::; , : i ..:.... ...... Y,r+..,.,,i'.i w. r... .�^ .: ,,, .,. .... ,.., WEATHER DATA Design Parameters: CityName.......................................................................................................... Orlando CFM Location.............................................................................................................. Florida CFM Latitude.................................................................................................................... 28.4 Deg. Longitude................................................................................................................. 81.3 Deg. Elevation............................................................. ................................................. 105.0 ft Summer Design Dry-Bulb........................................................................................ 94.0 IF Summer Coincident Wet-Bulb.................................................................................. 76.0 IF SummerDaily Range............................................................................................... 16.6 IF Winter Design Dry-Bulb........................................................................................... 37.0 IF Winter Design Wet-Bulb.......................................................................................... 31.1 IF Atmospheric Clearness Number.............................................................................. 0.90 MBH Average Ground Reflectance.................................................................................. 0.20 CFM Soil Conductivity.................................................................................................... 0.800 BTU/(hr-ft-°F) Local Time Zone (GMT +/- N hours).......................................................................... 5.0 hours Consider Daylight Savings Time................................................................................. No 1003 ft2 0 SimulationWeather Data.................................................................................. noneN/A Current Data is...................................................................... 2001 ASHRAE Handbook Design Cooling Months............................................................... January to December gprn HVAC LOAD CALCULATIONS Air System Information Air System Name ................................ BLOCK LOAD CFM Equipment Class ............................................ UNDEF CFM Air System Type .................................................. VAV CFM/ft2 Sizing Calculation Information 79,6/67.6 IF Zone and Space sizing Method: 0 CFM Zone CFM .......................... Peak zone sensible load CFM/ft2 Space CFM .................. Individual peak space loads IF Central Cooling Coil Sizing Data 0.100 Zone Total coil load ......................................................... 1.9 Tons Total coil load ....................................................... 23.3 MBH Sensible coil load ................................................. 19.8 MBH Coil CFM at Jan 1300 ............................................ 944 CFM Max block CFM ..................................................... 944 CFM Surn of peak zone CFM ......................................... 944 CFM Sensible heat ratio .............................................. 0.851 1003 ft2 0 11:2/Ton................................................................. 516.9 BTU/(hr-ft2)........................................................... 23.2 Water flow @ 10.0 IF rise ..................................... 4.66 gprn Supply Fan Sizing Data Actual rnax CFM .................................................... 944 CFM StandardCFM ....................................................... 940 CFM Actual max CFM/ft2............................................... 0.94 CFM/ft2 Outdoor Ventilation Air Data 79,6/67.6 IF Design airflow CFM ................................................... 0 CFM CFM/ft2.................................................................0.00 55.0/53.9 CFM/ft2 Number of zones.......................................................... 1 Floor Area............................................................ 1003.0 ft2 Location ............................................... Orlando, Florida Calculation Months ....................................... Jan to Dec Design Sizing Data .............................................. User -Modified Maximum Load occurs at ................................................. Jan 1300 HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 'F / 31.1 IF OADB/WB................................................... 79,6/67.6 IF Entering DB / WB ........................................... 74.5/62.5 IF Leaving DB / WB ........................................... 55.0/53.9 IF CoilADP.................................................................. 52.8 IF Bypass Factor........................................................ 0.100 Zone ResultingRH.............................................................. 52 % Design supply temp ................................................. 55.0 IF Zone T -stat Check .............................................. f) of 1 OK Max zone temperature deviation .................. 944 213 Fan motor BHP ........................................................ 0.10 BHP Fan motor kW .......................................................... 0.08 kW Fanstatic................................................................. 0.75 in wg CFM/person........................... ..................... I............ 0.00 CFM/person HVAC LOAD CALCULATIONS Air System Information Air System Narne................................ BLOCK LOAD Equipment Class ............................................ UNDEF Air System Type .................................................. VAV Sizing Calculation Information Zone and Space Sizing Method: Zone CFM .......................... Peak zone sensible load Space CFM .................. Individual peak space loads Zone Sizing Data Number of zones........................................................... 1 Floor Area........................................................... 1003.0 ft% Location ............................................... Orlando, Florida Calculation Months ....................................... Jan to Dec Sizing Data ............................................. User -Modified Zone Terminal Sizing Data No Gone '? errninai Sizing Datarequired for this ,3ysten'l. Space Loads and Airflows Zone Name / Space Name Maximum Design Minimum Time Maximum Zone Zone 7 HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 'F / 31.1 IF Cooling Air Air of Heating Floor 1 13.0 Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) (CFM) (CFM) Load (MBH) (ft2) CFM/ft2 Zone 1 17.3 944 213 Jan 1900 0.0 1003.0 0.94 Zone Terminal Sizing Data No Gone '? errninai Sizing Datarequired for this ,3ysten'l. Space Loads and Airflows Zone Name / Space Name Mult. Cooling Sensible (MBH) Time Air of Flow Load (CFM) Heating Load (MBH) Floor Area (ft2) Space CFM/ft2 Zone 7 HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 'F / 31.1 IF ZONE LOADS Sensible Latent Details (BTU/hr) (BTU/hr) Sensible Latent Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads Sales 1 13.0 Jan 1900 709 0.0 799.0 0.89 Stock Room 1 3.9I Jan 21001 211 0.0 144.0 1.46 Restroom 1 0.51 Jan 21001 25 0.0 60,0 0.42 ["_� - 3/4" 1/2" 3/4" 1/2" LAV -'1 EWH-1 1/2" WC -1 1/2" (TO TRAP PRIMER) WATER RISER M2.04 SCALE: NTS SECTIONS SIDE VIEWS 5/16" DIA. ALL THREAD SECURED TO STRUCTURE ABOVE. ROUND RIGID DUCT (SPIRAL SEAM) 1 1/2" WIDE, 16 GA. SUPPORT STRAP WITH 61-0" MAX. SPACING, WITH WASHERS AND LOCK NUTS. SUPPORT WIRE SECURED TO STRUCTURE ABOVE. ROUND RIGID DUCT (LOGITUDINAL SEAM) 1" WIDE, 18 GA. SUPPORT STRAP WITH 5'-0" MAX. SPACING. SUPPORT WIRE SECURED TO STRUCTURE ABOVE. FLEXIBLE DUCT, 5'-0" MAXIMUM LENGTH 2" WIDE SUPPORT STRAP WITH 3'-0" MAX. SPACING. ROUND DUCT SUPPORT M21-,®2 SCALE: NTS LANDLORD PLUMBING NOTES: 1. ANY CHANGES AND/ OR UPGRADES TO TENANT'S EXISTING PLUMBING SYSTEMS SHALL COMPLY WITH ALL CODES AND MALL CRITERIA. EXISTING SYSTEMS SHALL POSSESS THE CAPACITY TO HANDLE ANY AND ALL CHANGES IN LOAD. 2. ALL WATER LINES SHALL BE COPPER - PVC IS NOT PERMITTED. THERE SHALL BE NO PIPING JOINTS OR FITTINGS INSTALLED IN WATER PIPING BELOW THE FLOOR SLAB. 3. ALL DRAIN, WASTE AND VENT FITTINGS ABOVE GRADE MUST BE CAST IRON PIPE. 4. PLUMBING IS NOT PERMITTED IN ANY DEMISING PARTITIONS. FURR OUT THE WALL AS NECESSARY. 5. EXHAUST AND PLUMBING VENTS SHALL BE LOCATED A MINIMUM OF 10'-0" FROM ANY OUTSIDE AIR INTAKE, AND 5'41 FROM ANY DEMISING WALL VERTICAL PLANE. 6. ALL FLOOR DRAINS ARE REQUIRED TO HAVE TRAP PRIMERS. 7. COORDINATE ALL CONCRETE TRENCHING/ CORING TO ENSURE THAT ANY UNDER SLAB UTILITIES, ETC., ARE NOT DAMAGED DURING FLOOR CUT. ANY DAMAGES TO BE REPAIRED AT TENANTS EXPENSE. PRIOR TO APPROVAL AND COORDINATION WITH PROPERTY MANAGEMENT IS REQUIRED FOR ALL CONCRETE CUTTING. 8. ANY UNUSED PLUMBING EQUIPMENT, PIPING, ETC., WITHIN OR SERVING THE PREMISES MUST BE COMPLETELY REMOVED TO POINT OF ORIGIN. DO NOT ABANDON IN PLACE. 9. ALL FLOOR PENETRATIONS MUST BE CORE BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND A MINIMUM OF 4" AFF. 10. IF NOT ALREADY EXISTING, INSTALL A SHUT OFF VALVE ON DOMESTIC WATER LINE INSIDE SPACE. 11. TENANT IS REQUIRED TO INS -PALL A WATERPROOF MEMBRANE IN ALL WET AREAS OF THE SPACE. TENANT HALL USE A 30 MIL POLYETHYLENE CLEAVAGE MEMBRANE (EQUAL TO NOBLESEAL TS) INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND ANSI A108. MEMBRANE MUST BE EXTENDED UP THE WALL A MINIMUM OF 4" OR EQUAL TO THE HEIGHT OF THE FLOOR BASE. LANDLORD NOTES: 1. NO PVC OR PEX ABOVE GRADE. 2. PLUMBING IS NOT PERMITTED IN LANDLORDS DEMISING WALLS. FURR OUT WALLS WHEN NECESSARY. 3. ALL TOILET ROOMS TO HAVE FLOOR DRAINS WITH TRAP PRIMERS. 4. G.C. TO COORDINATE ALL FLOOR CUTS AND CONNECTIONS TO LL WATER AND SANITARY MAINS WITH MALL OPERATIONS. 2" FCO LAV -1 FDA WC -1 3.. 2" 2rr 4" \ 0-/ 4" WASTE AND VENT RISER M2.03 SCALE: NTS (E) COLD WATER DOWN IN CHASE (E) VENT UP IN WALL E LAV 1 COLD WATER TO l FAUCET 1 HOT WATER TO FAUCET - 3 -WAY ANGLE STOP VALVE `-(E) WASTE PIPE DRAIN-----.,- FLOOR PLUG PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. SET HEATER THERMOSTAT TO 104 DEGREES. POINT OF USE WATER HEATER M2=01 SCALE: NTS "d PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FE 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 i a�• No 43722 3'� E V s CONAL ''�i+a�v't�+� NOV 2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS DRAWING NUMBER MM 2 MECHANICAL DETAILS rl 11"', ,4 '.��; r�, a �. Boa v , a :x';':: a :: „ , , ,,, .::: ,: .. ':, ., x r.. „x„x .... . .. .... ..... ....... . .... .... ,.. ,..,... > . W ,, a.. ,, .a ...a. .,.:,.r ,..�, ,.,,,, ,,,. .,,. :.:„ ,,,, .:a,..., ,,,,,,, .., , ., ..,.: ,. ,. :......,.:... .. ,.. .. .,. . , ....., „.. .. .., .., : ,...,, .,..,,.. ., ,.., ... : <.,., .,..: x, ,,, .:. , :.,, : , .. . ,.,.. .., .. .a. x, ,,.:,, :. „, ,:, ,. ., ,., . ,.,. ,,.,, „ ... . ,..... ...,.. ,. .. ,....... < e, DESIGN COOLING DE(:,3IGN HEATING COOLING DATA AT Jan 1300 COOLING OA DB / WB 79.6 IF / 67.6 IF HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 'F / 31.1 IF ZONE LOADS Sensible Latent Details (BTU/hr) (BTU/hr) Sensible Latent Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 0 ft2 - Wall Transmission 0 ft2 0 0 ft2 0 Roof Transmission 0 ft2 0 0 ft2 0 Window Transmission 0 ft2 0 0 ft2 0 Skylight Transmission 0 ft2 0 0 ft2 0 Door Loads 0 ft2 0 0 ft2 0 Floor Transmission 1003 ft2 0 1003 ft2 0 Partitions 0 ft2 0 0 ft2 0 Ceiling 0 ft2 0 0 ft2 0 Overhead Lighting 1059 W 2925 0 0 Task Lighting 1598 W 4341 0 0 Electric Equipment 1250 W 0 0 People _4197 15 J 2498 3007 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 15%/15% 2094 451 10% 0 0 >> Total Lone Loads 16055 3458 0 0 Zone Conditioning - 19544 3458 - -1709 0 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 0% 0 0 0 Plenum Lighting Load 0% 0 0 0 Return Fan Load 944 CFM 0 - 213 CFM 0 Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 944 CFM 283 - 213 CFM -99 Space Fan Coil Fans - 0 - 0 Duct Heat Gain / Loss 0% 0 - 0% 0 >> Total System Loads 19827 3458 -1808 0 Central Cooling Coil 19827 3458 -1808 0 >> Total Conditioning 19827 3458 -1808 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads ["_� - 3/4" 1/2" 3/4" 1/2" LAV -'1 EWH-1 1/2" WC -1 1/2" (TO TRAP PRIMER) WATER RISER M2.04 SCALE: NTS SECTIONS SIDE VIEWS 5/16" DIA. ALL THREAD SECURED TO STRUCTURE ABOVE. ROUND RIGID DUCT (SPIRAL SEAM) 1 1/2" WIDE, 16 GA. SUPPORT STRAP WITH 61-0" MAX. SPACING, WITH WASHERS AND LOCK NUTS. SUPPORT WIRE SECURED TO STRUCTURE ABOVE. ROUND RIGID DUCT (LOGITUDINAL SEAM) 1" WIDE, 18 GA. SUPPORT STRAP WITH 5'-0" MAX. SPACING. SUPPORT WIRE SECURED TO STRUCTURE ABOVE. FLEXIBLE DUCT, 5'-0" MAXIMUM LENGTH 2" WIDE SUPPORT STRAP WITH 3'-0" MAX. SPACING. ROUND DUCT SUPPORT M21-,®2 SCALE: NTS LANDLORD PLUMBING NOTES: 1. ANY CHANGES AND/ OR UPGRADES TO TENANT'S EXISTING PLUMBING SYSTEMS SHALL COMPLY WITH ALL CODES AND MALL CRITERIA. EXISTING SYSTEMS SHALL POSSESS THE CAPACITY TO HANDLE ANY AND ALL CHANGES IN LOAD. 2. ALL WATER LINES SHALL BE COPPER - PVC IS NOT PERMITTED. THERE SHALL BE NO PIPING JOINTS OR FITTINGS INSTALLED IN WATER PIPING BELOW THE FLOOR SLAB. 3. ALL DRAIN, WASTE AND VENT FITTINGS ABOVE GRADE MUST BE CAST IRON PIPE. 4. PLUMBING IS NOT PERMITTED IN ANY DEMISING PARTITIONS. FURR OUT THE WALL AS NECESSARY. 5. EXHAUST AND PLUMBING VENTS SHALL BE LOCATED A MINIMUM OF 10'-0" FROM ANY OUTSIDE AIR INTAKE, AND 5'41 FROM ANY DEMISING WALL VERTICAL PLANE. 6. ALL FLOOR DRAINS ARE REQUIRED TO HAVE TRAP PRIMERS. 7. COORDINATE ALL CONCRETE TRENCHING/ CORING TO ENSURE THAT ANY UNDER SLAB UTILITIES, ETC., ARE NOT DAMAGED DURING FLOOR CUT. ANY DAMAGES TO BE REPAIRED AT TENANTS EXPENSE. PRIOR TO APPROVAL AND COORDINATION WITH PROPERTY MANAGEMENT IS REQUIRED FOR ALL CONCRETE CUTTING. 8. ANY UNUSED PLUMBING EQUIPMENT, PIPING, ETC., WITHIN OR SERVING THE PREMISES MUST BE COMPLETELY REMOVED TO POINT OF ORIGIN. DO NOT ABANDON IN PLACE. 9. ALL FLOOR PENETRATIONS MUST BE CORE BORED, SLEEVED, GROUTED, SEALED AND MADE WATERPROOF. SLEEVES MUST EXTEND A MINIMUM OF 4" AFF. 10. IF NOT ALREADY EXISTING, INSTALL A SHUT OFF VALVE ON DOMESTIC WATER LINE INSIDE SPACE. 11. TENANT IS REQUIRED TO INS -PALL A WATERPROOF MEMBRANE IN ALL WET AREAS OF THE SPACE. TENANT HALL USE A 30 MIL POLYETHYLENE CLEAVAGE MEMBRANE (EQUAL TO NOBLESEAL TS) INSTALLED PER MANUFACTURERS RECOMMENDATIONS AND ANSI A108. MEMBRANE MUST BE EXTENDED UP THE WALL A MINIMUM OF 4" OR EQUAL TO THE HEIGHT OF THE FLOOR BASE. LANDLORD NOTES: 1. NO PVC OR PEX ABOVE GRADE. 2. PLUMBING IS NOT PERMITTED IN LANDLORDS DEMISING WALLS. FURR OUT WALLS WHEN NECESSARY. 3. ALL TOILET ROOMS TO HAVE FLOOR DRAINS WITH TRAP PRIMERS. 4. G.C. TO COORDINATE ALL FLOOR CUTS AND CONNECTIONS TO LL WATER AND SANITARY MAINS WITH MALL OPERATIONS. 2" FCO LAV -1 FDA WC -1 3.. 2" 2rr 4" \ 0-/ 4" WASTE AND VENT RISER M2.03 SCALE: NTS (E) COLD WATER DOWN IN CHASE (E) VENT UP IN WALL E LAV 1 COLD WATER TO l FAUCET 1 HOT WATER TO FAUCET - 3 -WAY ANGLE STOP VALVE `-(E) WASTE PIPE DRAIN-----.,- FLOOR PLUG PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT FIELD CONDITIONS. SET HEATER THERMOSTAT TO 104 DEGREES. POINT OF USE WATER HEATER M2=01 SCALE: NTS "d PARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FE 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 i a�• No 43722 3'� E V s CONAL ''�i+a�v't�+� NOV 2 0 2013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS DRAWING NUMBER MM 2 MECHANICAL DETAILS rl 11"', ,4 '.��; r�, a �. Boa v , a :x';':: a :: „ , , ,,, .::: ,: .. ':, ., x r.. „x„x .... . .. .... ..... ....... . .... .... ,.. ,..,... > . W ,, a.. ,, .a ...a. .,.:,.r ,..�, ,.,,,, ,,,. .,,. :.:„ ,,,, .:a,..., ,,,,,,, .., , ., ..,.: ,. ,. :......,.:... .. ,.. .. .,. . , ....., „.. .. .., .., : ,...,, .,..,,.. ., ,.., ... : <.,., .,..: x, ,,, .:. , :.,, : , .. . ,.,.. .., .. .a. x, ,,.:,, :. „, ,:, ,. ., ,., . ,.,. ,,.,, „ ... . ,..... ...,.. ,. .. ,....... < e, „. , ,...„ exR R , ..., .. .,.,x.,v„a :.,, eo ..+.a er � uveu„ .. e,, .., ,,w. ,, ,.. ..... , ., r ,, vv ,:xx , cz.,., x ,, , .. ..ot ' ... , ., .. @ ^... .. . .w . . .^., r r w. s nr..rw. wtau....,,... ... .,, ,..,r . , r . n„ ,. ,^, ,.,..r,e xr!4 4t ti.Ar rwxrw r.. rR<n, rr n..,,: a^w,w .,w., r ..r,.mu..w.w. r uu.. ..wrru,+lv,ru.u. , .... 1 . DIVISION 15000 - MECHANICAL SECTION 15001 - BASIC MECHANICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 15000. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTOR'S WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WORK TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE ON THE ELECTRICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 16002 - GENERAL REQUIREMENTS A. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE COMPLETE MECHANICAL SYSTEM AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD, OR TENANT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH LANDLORD, AND THE TENANT PROJECT MANAGER AS REQUIRED, B. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. C. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. D. ALL MECHANICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. E. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. F. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LAEORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 15003 - CODES A. ALL WORK SHALL CONFORM TO THE LANDLORDS' CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE OWNER TO THE CONTRACTOR, SECTION 15004 - LICENSES, PERMITS, INSPECTIONS & FEES A. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. B. FURNISH TO THE TENANT'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 15005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS A. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WI'_L BE SUBJECT TO APPROVAL IN WRITING BY TENANT'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS, FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. SECTION 15010 - CUTTING AND PATCHING A. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. B. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FURNISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND TENANT'S PROJECT MANAGER. C. EXISTING UTILITIES, ETC, THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGER. SECTION 15011 - SLEEVES A. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROJECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. B. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. C. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO 22 U.S.G GALVANIZED STEEL MINIMUM. SECTION 15012 - HANGERS A. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C -CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. B. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, AND IN ORDER TO SUPPORT DUCTWORK OR PIPING, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, AND OTHER EQUIPMENT. HANGER TYPES AND INSTALLATION METHODS ARE ALSO SUBJECT TO LANDLORD CRITERIA, C. HANGERS FOR ALL INSULATED PIPING SHALL BE SIZED AND INSTALLED FOR THE OUTER DIAMETER OF INSULATION. INSTALL 6" LONG SPLIT CIRCLE GALVANIZED SADDLE BETWEEN THE HANGER AND THE PIPE INSULATION. D. HANGERS AND PIPING OF DISSIMILAR METALS SHALL BE DI -ELECTRICALLY SEPARATED. DIVISION 15300 - FIRE PROTECTION (IF APPLICABLE) SECTION 15301 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE SPRINKLER SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO DE IN LU BUT NOT BE LIMITED TO THE FOLLOWING: INCLUDE, 1 r MODIFICATIONS TO EXISTING WET SPRINKLER SYSTEM AS REQUIRED TO PROVIDE COVERAGE IN ACCORDANCE, NFPA-13, LOCAL CODES, AND LANDLORD'S CRITERIA. 2. TAPS, RISERS, LATERALS, BRANCHES, VALVES, ALARMS, SPRINKLER HEADS AND ALL COMPONENTS REQUIRED FOR A COMPLETE SYSTEM. 3. DESIGN DRAWINGS, HYDRAULIC CALCULATIONS, SUBMITTALS AND APPROVALS. 4. PERMITS, FEES, INSPECTIONS AND CHARGES. 5. TESTS AND TEST CERTIFICATES. 6. IT IS INTENDED THAT THE CONTRACTOR SHALL PROVIDE A COMPLETE AND FUNCTIONAL SYSTEM.. B. THIS FIRE PROTECTION CONTRACTOR IS RESPONSIBLE FOR SUBMITTING COORDINATED DRAWINGS, HYDRAULIC CALCULATION, HEAD TYPE AND COLORS TO ALL AUTHORITIES HAVING JURISDICTION FOR APPROVAL. NO WORK SHALL BEGIN UNTIL ALL APPROVALS HAVE BEEN RECEIVED. SECTION 16202 - MATERIALS A. SPRINKLER HEADS: 1. ALL SPRINKLER HEADS SHALL BE NEW U.L., F.M. LISTED AND APPROVED AUTOMATIC SPRAY TYPE AS MANUFACTURED BY GRINNELL, RELIABLE, STAR, OR VIKING. 2. ALL SPRINKLER HEADS SHALL BE RATED FOR 165°F UNLESS INDICATED OTHERWISE ON DRAWINGS OR REQUIRED BY LOCAL CODES. 3. VERIFY HEAD TYPES AND COLORS WITH TENANT AND SUBMIT WITH SPRINKLER DRAWINGS FOR PERMIT. 4. LOCATIONS OF ALL HEADS SHOULD BE APPROVED BY TENANT AND THE LOCAL FIRE PROTECTION OFFICIAL BEFORE INSTALLATION. a. SALES/TOILET ROOMS AT GYP. BD. CLG - FULLY RECESSED WITH COVER PLATES TO MATCH GYP. BD. FINISH. b. SALES AREA AT A.G.T. CLG. - SEMI -RECESSED CHROME WITH WHITE ESCUTCHEONS. c. STOCKROOM/CORRIDOR -BRASS PENDANT. d. STOREFRONT - FULLY RECESSED HEADS WITH COVER PLATES TO MATCH GYP. BD. FINISH. B PIPING: 3. INTERIOR CONDENSATE PIPING SHALL BE TYPE "L" HARD DRAWN COPPER TUBE WITH 95-5 TIN -ANTIMONY SOLDERED JOINTS AND WROUGHT COPPER FITTINGS WITH DIELECTRIC SEPARATION BETWEEN DISSIMILAR METALS. EXTERIOR CONDENSATE PIPING MAY BE SCHEDULE 40 PVC PIPING WITH SOLVENT WELDED FITTINGS IF APPROVED FOR USE BY THE LANDLORD. C. POTABLE WATER PIPING 1. BELOW GRADE: TYPE W, ANNEALED TEMPERED COPPER TUBE FOR PIPE SIZES 2 INCHES AND SMALLER. BRAZE ALL JOINTS. 2.ALL OTHER: TYPE'U HARD DRAWN COPPER TUBE WITH SWEAT JOINTS AND CAST WROUGHT COPPER FITTINGS AND 95-5 TIN -ANTIMONY SOLDER. D. PIPING OF DISSIMILAR METALS MUST BE DI -ELECTRICALLY SEPARATED. E. INSULATE ALL HOT WATER, COLD WATER AND INTERIOR CONDENSATE PIPING WITH 1" THICK (K=0.23 @ 75"F) PIPE INSULATION WITH AN ALL SERVICE JACKET TO MEET LOCAL CODES AND UL FLAME SPREAD AND SMOKE DEVELOPED RATINGS. OWENS-CORNING OR EQUAL. F. INSULATE THE TRAP, SANITARY AND SUPPLY PIPES UNDER LAVATORY WITH 1/2" ARMSTRONG "ARMAFLEX" PIPING INSULATION OR TRUEBRO MODEL 102W WHITE "HAND LAV GUARD" INSULATION KIT TO COMPLY WITH ADA REQUIREMENTS. G. INSTALL AIR CHAMBER SHOCK ABSORBERS IN BOTH HOT AND COLD LINES OF PIPING SYSTEM TO PREVENT NOISE AND DAMAGE DUE TO WATER HAMMER. SIOUX CHIEF 650 SERIES ALL STAINLESS STEEL, OR EQUAL. J.R. SMITH "HYDROTROLS", INSTALLED IN AN UPRIGHT POSITION. H. ALL BRANCH PIPING SYSTEM SHALL HAVE ACCESSIBLE SERVICE VALVE. PROVIDE SHUT OFF VALVES IN THE SUPPLY PIPING TO EVERY FIXTURE. PROVIDE ACCESS DOORS WHERE NECESSARY. 1. INSTALL ALL NECESSARY PIPE HANGERS, SADDLES, AND CARRIERS TO PROPERLY SUPPORT ALL PIPING AND FIXTURES. HANGERS SHALL SUIT TYPE OF PIPING INSTALLED AND BE SPACED AT A MAXIMUM SPAN OF 5 FEET. PROVIDE SWAY AND SEISMIC BRACING WHERE REQUIRED BY CODES. J. STERILIZE WATER SYSTEM IN ACCORDANCE WITH LOCAL CODES. K. CLEAWOUTS AND FLOOR DRAINS SHALL BE INSTALLED PER LOCAL CODES. ALL FLOOR DRAINS SHALL HAVE DEEP SEAL TRAPS. PROVIDE TRAP PRIMERS FOR FLOOR DRAINS. L. ESCUTCHEONS SHALL BE CHROME PLATED, SIZE AS REQUIRED AND PLACED AT ALL PIPE PENETRATIONS AT WALLS, FLOORS. AND CEILINGS IN FINISHED AREAS. M. LEAKAGE TESTS SHALL BE PER LOCAL CODES. N. FLASHING SHALL BE SEALED WATERTIGHT AND PERFORMED IN ACCORDANCE TO THE LANDLORD'S CRITERIA. USE A LANDLORD APPROVED ROOFING CONTRACTOR WHERE APPLICABLE AND INCLUDE ALL COSTS IN BID. 0. PROVIDE WATER METER AND REMOTE READER PER LANDLORD'S CRITERIA OR LOCAL UTILITIES REQUIREMENTS IF APPLICABLE. -. P. GAS PIPING: 1. PROVIDE A COMPLETE GAS PIPING SYSTEM IF APPLICABLE. REFER TO PLANS TO DETERMINE IF A GAS SYSTEM IS REQUIRED. 2. GAS LINES SHALL BE BLACK STEEL, SCHEDULE 40, ASTM A-120, WITH MALLEABLE THREADED FITTINGS FOR 2" AND SMALLER, AND WITH WELDED JOINTS FOR 2-1/2" AND LARGER. 3. PROVIDE A GAS COCK, DIRT LEG, AND UNION CONNECTION TO EACH PIECE OF EQUIPMENT, 4. PITCH PIPING AT A UNIFORM GRADE OF 1/4" IN 15 FEET UPWARD IN DIRECTION OF FLOW. SUPPORT PIPING EVERY 5 FEET. SUPPORT AS REQUIRED BY LANDLORD CRITERIA, AS DETAILED ON DRAWINGS, OR BY STANDARD INDUSTRY PRACTICE, WHICHEVER IS MORE STRINGENT. 5. GAS PIPING EXPOSED ON ROOF MUST BE PRIMED AND PAINTED WITH RUST -INHIBITING PAINT. 6. GAS PIPING INSTALLED IN RETURN AIR PLENUMS SHALL BE SLEEVED AND VENTED OR WELDED IN ACCORDANCE WITH THE LOCAL GAS COMPANY, LOCAL CODE, AND APPLICABLE NFPA 54 CODES. 7. TESTING AND PURGING OF GAS PIPING SHALL BE DONE PER THE REQUIREMENTS OF THE LOCAL GAS COMPANY, LOCAL CODES, AND APPLICABLE NFPA 54 CODES. 8. CONTACT AND COORDINATE GAS SERVICE AND METER REQUIREMENTS WITH THE LOCAL GAS COMPANY AND THE MALL'S OPERATIONS MANAGER PRIOR TO BID. INCLUDE INSTALLATION OF GAS METER AND REGULATOR COSTS IN BID. DIVISION 15500 - HEATING, VENTILATING, AIR CONDITIONING SECTION 15501 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE HVAC SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, SHOWN ON DRAWINGS AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. NEW WATER SOURCE HEAT PUMP, EXISTING EXHAUST FAN, SUPPLY, RETURN AND EXHAUST DUCTWORK WITH ALL CONTROLS AND ACCESSORIES SPECIFIED TO REMAIN. 2. THE AIR DEVICES AS NOTED ON THE PLANS SHALL BE PURCHASED BY THE CONTRACTOR. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SCHEDULING, RECEIVING, VERIFYING QUANTITIES AND INSPECTING FOR DAMAGE AND FILING OF ANY CLAIM FORMS. REFER TO RESPONSIBILITY SCHEDULE AND AIR DEVICE SCHEDULE ON PLANS. 3, ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFY ALL DIMENSIONS AT THE SITE. 4. ALL VALVES, DAMPERS, ETC. SHALL BE SO LOCATED AND INSTALLED TO PERMIT ACCESS FOR SERVICE WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS. SECTION 15502 - MATERIALS AS MINIMUM. H: DUCTWORK INSULATION 1. INSTALL INSULATION PRODUCTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS, AND IN ACCORDANCE WITH RECOGNIZED INDUSTRY PRACTICES. INSULATION MUST COMPLY WITH NFPA 90A. 2. DUCT SIZES SHOWN ON DRAWINGS ARE INSIDE CLEAR DIMENSIONS. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH 1 '/2" THICK, 1-1/2 LB. DENSITY DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE, EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. 3. ALL ROUND, MEDIUM PRESSURE AND OUTSIDE AIR DUCTWORK SHALL BE EXTERNALLY INSULATED WITH A MINIMUM OF 2" THICJ, 1 LB. DENSITY (R=5.6) DUCT WRAP WITH VAPOR BARRIER. VAPOR BARRIER IS TO BE MAINTAINED THROUGHOUT DUCT SYSTEM. ALL JOINTS MUST BE TAPED SO THAT NO INSULATION FIBER IS VISIBLE. EXTEND DUCTWORK INSULATION WITHOUT INTERRUPTION THROUGH WALLS, FLOORS, AND SIMILAR PENETRATIONS. K. TESTING, ADJUSTING, AND BALANCING 1. CONTRACTOR SHALL BALANCE, ADJUST & TEST EQUIPMENT TO PROVIDE DESIGN AIR QUANTITIES AND ASSURE PROPER OPERATION OF SYSTEMS. CONTRACTOR SHALL SUBMIT COPIES OF BALANCE/TEST REPORT TO OWNER FOR REVIEW PRIOR TO COMPLETION OF PROJECT. IF A CERTIFIED TEST AND BALANCE REPORT IS REQUIRED BY LANDLORD, CONTRACTOR SHALL COORDINATE ALL REQUIREMENTS WITH LANDLORD AND LOCAL AUTHORITY HAVING JURISDICTION, CONTRACT DIRECTLY WITH AN APPROVED TESTING AND BALANCING AGENCY, AND PROVIDE COMPLETE REPORT TO OWNER AND LANDLORD. 2. IF REQUIRED BY THE LANDLORD OR THE LOCAL AUTHORITY HAVING JURISDICTION THE BALANCE REPORT SHALL BE ON THE AABC NATIONAL STANDARD REPORT FORMS OR THE NEBB CERTIFIED REPORT FORMS AS PUBLISHED IN THEIR MOST CURRENT EDITIONS AND SHALL INCLUDE AS A MINIMUM TH EFOLLOWING INFORMATION: a. AABC OR NEBB CERTIFICATION NUMBER AND SIGNATURE OF BALANCING CONTRACTOR. b. B. COPY OF A CERTIFICATE OF CONFORMANCE WITH NATIONAL STANDARDS FOR THIS PROJECT. c. INSTRUMENTATION LIST WITH LAST CALLIBRATION DATES. d. MAKE AND MODEL NUMBERS OF ALL HVAC EQUIPMENT TESTED. e. AIR CFM AND STATIC PRESSURE READINGS (DISCHARGE AND SUCTION) AS MEASURED BY PITOT TUBE DUCT TRAVERSE AT THE UNIT. f. MONITOR NAMEPLATE DATA WITH ACTUAL FIELD VOLTAGE AND AMPERAGE READINGS FOR EACH LEG. g. MOTOR AND FAN RPMS, SHEAVE SIZES AND BELT SIZES. h. OUTSIDE, RETURN, MIXED AND SUPPLY AIR TEMPERATURES AND VOLUMES SHALL BE MEASURED AT FULL COOLING WITH MINIMUM OUTSIDE AIR. RETURN/RELIEF/SMOKE EVACUATION AIRFLOW SHALL BE BALANCED AND MEASUREMENTS RECORDED BY PITOT DUCT TRAVERSE AT FULL ECONOMIZER AND POWER EXHAUST. L MAKE AND MODEL NUMBERS OF ALL AIR DISTRIBUTION EQUIPMENT. j. FINAL BALANCED AIR VOLUMES AT ALL OUTLETS (INCLUDING RETURNS WHERE DUCTED). k. INDEXED PLAN WITH DIFFUSED AND RETURN LOCATIONS. ALSO INDICATE IF DIFFUSER IS 3 -WAY OR 2 -WAY. I. FINAL BALANCED GPM AT ALL UNITS FOR CHILLED/HOT/CONDENSER WATER WHEN APPLICABLE. m.CHILLED/HOT/CONDENSER ENTERING AND LEAVING WATER TEMPERATURES WHEN APPLICABLE. n. PRESSURE DROP THROUGH COILS AND CONTROL VALVES WHEN APPLICABLE. 3. IF REQUIRED BY THE LANDLORD OR THE LOCAL AUTHORITY HAVING JURISDICTION THE GENERAL CONTRACTOR SHALL ARRANGE FOR THE TEST AND BALANCE A MINIMUM OF TWO WEEKS PRIOR TO THE REQUIRED DATE AFER RETURNING TABC'S "START UP CHECK LIST". ALL WORK SHALL BE COMPLETED PRIOR TO SCHEDULING AIR BALANCE. IN ADDITION, THE BALANCE CONTRACTOR WILL INSPECT AND PREPARE A FINAL PUNCH LIST. THE HVAC CONTRACTOR SHALL REPAIR OR REPLACE ANY DEFECTIVE MATERIALS, EQUIPMENT OR WORKMANSHIP PRIOR TO TENANT'S FINAL WALK THRU AND BEFORE FINAL PAYMENT WILL BE MADE. 4. FOUR COPIES OF THE BALANCE REPORT SHALL BE SUBMITTED TO TENANT AND FOUR COPIES TO THE LANDLORD FOR APPROVAL. 5. OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: a. EQUIPMENT CAPACITY (INPUT AND OUTPUT) AND REQUIRED MAINTENANCE ACTIONS. b. EQUIPMENT OPERATION AND MAINTENANCE MANUALS. c. HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS; DESIRED OR FIELD -DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS, d. COMPLETE NARATIVE OF HOW EACH SYSTEM IS INTENDED TO OPERATE. ALL PIPING SHALL WITHSTAND AIR PRESSURE TESTING PER GOVERNING PLUMBING CODE. A. HYDRONIC PIPING 1. HYDRONIC PIPING FOR CHILLED WATER, CONDENSER WATER AND/OR HEATING WATER SHALL BE ASTM A-53, SCHEDULE 40, ERW, BLACK STEEL PIPE WITH PLAIN ENDS. INSTALL STEEL PIPE WITH WELDED JOINTS WHERE PIPE IS 2-1/2 INCH AND LARGER. INSTALL STEEL PIPE WITH THREADED JOINTS AND FITTINGS. INSTALL TYPE "K" COPPER PIPE FOR 2 INCH AND SMALLER PIPE. PROVIDE DIELECTRIC UNIONS BETWEEN DISSIMILAR METALS. ALL PIPING SHALL BE IN STRICT CONFORMANCE WITH ASTM, ASA, AND LANDLORD'S REQUIREMENTS. WHICHEVER IS MOST STRINGENT, UNIONS OR FLANGES MUST BE USED AT EQUIPMENT CONNECTIONS WHERE SERVICE OR REMOVAL MAY BE REQUIRED. 2. ALL PIPING AND EQUIPMENT SHALL BE PRESSURE TESTED WITHOUT LEAKAGE AT A MINIMUM PRESSURE OF 125 PSI. 3. ALL HYDRONIC PIPING AND EQUIPMENT CONNECTED TO THE HVAC PIPING SYSTEM SHALL BE CLEANED AND FLUSHED. REMOVE, CLEAN, AND REPLACE STRAINER SCREENS. FILL TENANT'S SYSTEM WITH DOMESTIC WATER AND VENT ALL PIPING AND EQUIPMENT PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM. CONTRACTOR LL TENANT'S SYSTEM WITH WATER FROM THE LANDLORD'S SYSTEM UNLESS SPECIFICALLY IWPARTNERS brand: operations : build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T W DPARTN E RS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #B11 C SANFOR®, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ,iI �3 ��W��� B. MECHANICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S PROJECT MANAGER S 0 S G DED AND SEAMLESS,B-36-10-700 Ar REFER TO PLANS FOR SCHEDULES OF EQUIPMENT. ALL EQUIPMENT SHALL BE COMPLETE IN EVERY RESPECT SHALL NOT FI ,oe� ��..;RNlST �'.fs, 1. SCHEDULE 40, BLACK STEEL PIPE, A TM A-53 F R FERROU PIPIN , WEL N AMLE , ANSI F R INSTRUCTED TO DO SO FROM THE LANDLORDS FIELD REPRESENTATIVE. ANY RUNS THRU A CHASE OR SHAFT v' P ,.• FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS WROUGHT STEEL PIPE. WITH ALL DEVICES APPURTENANCES, AND ACCESSORIES PROVIDED TO MEET THE DESIGN INTENT AND � �C•E•N19 41-. ®I FOR TENANT'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S CAST IRON OR MALLEABLE IRON SCREWED FITTINGS FOR PIPES 2 INCHES AND SMALLER. SCREWED OR CAST OPERATION OF THE SYSTEMS SHOWN ON THE DRAWINGS AND SPECIFIED HEREIN, EQUIPMENT SHALL BE WILL BE DONE WITH FEWEST JOINTS POSSIBLE USING THE LONGEST LENGTH OF HARD COPPER PIPE AVAILABLE. =` �C�; , PROGRESS. SUBMITTALS SHALL BEAR "THE STAMP OF GENERAL CONTRACTOR AND THE SUB -CONTRACTOR 2' SHOULD A JOINT BE REQUIRED, CONTRACTOR SHALL MAKE ALL EFFORTS TO KEEP THE JOINTS IN ACCESSIBLE;' No 43 722 > IRON FLANGED JOINTS FOR PIPES LARGER THAN 2 INCHES. INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. ALL AIR CONDITIONING U� 1 SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE 3. GALVANIZED OR BLACK MELLEABLE IRON WITH BRASS SEAT SCREWED UNIONS FOR PIPES 2 INCHES AND EQUIPMENT MUST BE TRAPPED IN ACCORDANCE WITH MANUFACTURERS DATA. AREAS. -- * * r * = I CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. _ � SMALLER. 4. PRIOR TO CONNECTION TO THE LANDLORD'S SYSTEM, CONTRACTOR SHALL OBTAIN WRITTEN CONFIRMATION 17� 00 4. VICTAULIC TYPE COUPLINGS ARE ACCEPTABLE, WHERE APPROVED BY CODE AND THE LANDLORD. B. METAL DUCTWORK - NO FIBERGLASS DUCT ALLOWED. 1 AT SECTION 15006 - GUARANTEE 1. EXCEPT AS OTHERWISE INDICATED FABRICATE AND INSTALL RECTANGULAR AND ROUND DUCTWORK WITH FROM 'TME LANDLORD'S FIELD REPRESENTATIVE, THAT ALL TESTING, FLUSHING, AND PROPER FILLING OF THE 5. HANGERS SHALL COMPLY WITH LANDLORD AND CODE REQUIREMENTS. TENANT'S SYSTEM HAS BEEN COMPLETED IN ACCORDANCE TO THE LANDLORD'S REQUIREMENTS AND THAT THE r3 ,> ` v' GALVANIZED STEEL, IN ACCORDANCE WITH SMACNA 'HVAC DUCT CONSTRUCTION STANDARDS' OF THE LATEST �� S I � % A. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND EDITION. TENANT's SYSTEM IS READY TO BE CONNECTED TO THE LANDLORD's SYSTEM. 6 "' F %o SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK MATERIAL, OR C. SPRINKLER SPACING SHALL NOT EXCEED 130 SQ. FT. IN "SALES" AREAS AND 100 SQ. FT. IN "STOCK" AREAS. i��o�l N At 1�s COMPLY WITH LANDLORD'S DESIGN CRITERIA. PIPE SIZING SHALL BE BASED ON NFPA ORDINARY HAZARD. 2. INSTALL TURNING VALVES IN ALL RIGHT ANGLE ELBOWS IN ALL DUCTS. EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN 3. INSTALL RIGIT ROUND AND RECTANGULAR METAL DUCT WITH SUPPORT SYSTEMS INDICATED IN SMACNA 5. PRESSURE/TEMPERATURE TEST PLUGS (PETE S PLUG) - 1/4 INCH NPT FITTINGS TO RECEIVE EITHER A WRITING) OF THE INSTALLATION BY THE TENANT'S PROJECT MANAGER. EXTENDED WARRANTIES ARE SPECIFIED STANDARDS. PROVIDE SWAY AND SEISMIC BRACING AS REQUIRED BY STATE AND LOCAL CODES OR BY TEMPERATURE OR PRESSURE PROBE, 1/8 INCH O.D. FITTING AND CAPS SHALL BE BRASS WITH VALVE CORE OF WITH INDIVIDUAL EQUIPMENT. D. ALL SPRINKLER LINES SHALL BE INSTALLED CONCEALED, AVOIDING INTERFERENCE WITH OTHER TRADES. LANDLORD. NORDEL, RATED AT 400 PSIG, 0 TO 200 DEGREES F. r= NOV 2 0 201 E. WHERE POSSIBLE, REWORK THE EXISTING SPRINKLER SYSTEM TO MEET THE NEW REQUIREMENTS OF THIS 4. ALL JOINTS AND SEAMS SHALL BE SEALED WITH UNITED MCGILL DUCT SEALER OR EQUAL. 125 PSIG CAST IRON BODY WITH PERFORATED STAINLESS STEEL SCREEN, SECTION 15007 RECORD DRAWINGS DESIGN AND INCLUDE ALL COSTS TO RAISE OR RELOCATE EXISTING PIPING TO OBTAIN CEILING HEIGHTS SHOWN a. ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS, AND CONNECTIONS IN DUCTWORK MUST BE SECURELY 6. STRAINERS - "Y" PATTERN STRAINERS, ON DRAWINGS. IN NEW CONSTRUCTION THE LANDLORD MAY PROVIDE ONLY A STUB -IN TO THE SPACE. THE SEALED USING WELDMENTS; MECHANICAL FASTENERS WITH SEALS, CASKETS, OR MASTICS; MESH AND THREADED FOR 2 INCHES AND SMALLER, FLANGED FOR 2 112 INCHES AND LARGER. SCREEN OPENING SIZE AT A. THIS CONTRACTOR SHALL MAIN -FAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM 0.033 INCH FOR HEATING AND 1/8 INCH FOR CHILLED OR CONDENSER WATER. PROVIDE WITH BLOWDOWN VALVEI ISSUE DATES CONTRACT DRAWINGS, SUCH AS: CONTRACTOR SHALL CONNECT AND EXTEND NEW PIPING AS REQUIRED, VERIFY ALL REQUIREMENTS PRIOR TO MASTIC SEALING SYSTEMS; OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELLED IN WITH HOSE END FITTING..10 BID. ACCORDANCE WITH UL 181A OR UL 1818. ALL LONGITUDINAL AND TRANSVERSE JOINTS, SEAMS AND PRELIM SET: 10-16-2013 1. LOCATION OF CONCEALED PIPING VALVES AND DUCTS. FINAL SET: 11-6-2013 2. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. CONNECTIONS OF SUPPLY AND RETURN DUCTS OPERATING AT STATIC PRESSURE LESS THAN OR EQUAL TO B. HYDRONIC PIPING GENERAL INSTALLATION qll D F. PROVIDE AND INSTALL A VALVED TEST CONNECTION IN AN ACCESSIBLE LOCATION FOR THE SPRINKLER SYSTEM 3. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND 2" W.G. SHALL BE SECURELY FASTENED AND SEALED WITH WELDS GASKETS, MASTICS (ADHESIVES), Q PERMIT SET: 11-20-2013 CONTRACTOR'S COORDINATION WITH OTHER TRADES. AS REQUIRED OR REQUESTED BY THE MALL, LOCAL INSPECTOR, OR TENANT'S INSURANCE CARRIER. MASTIC -PLUS -EMBEDDED FABRIC SYSTEMS OR TAPES INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 1. INSTALL WATER MAINS WITHOUT PITCH. USE ECCENTRIC REDUCING COUPLINGS AT CHANGES IN SIZE WITH THE TOP OF PIPES AT SAME ELEVATION. G. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE CAUSED BY LEAKS IN ANY OF THE EQUIPMENT INSTALLATION INSTRUCTIONS. y B. AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL INSTALLED BY THEM. ALL REPAIRS OR REPLACEMENT OF DAMAGES SHALL BE AT THIS CONTRACTOR'S EXPENSE. b. MECHANICAL FASTENERS AND SEALS, MASTICS, OR GASKETS MUST BE USED WHEN CONNECTING DUCTS TO . CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY 2. BRANCHES TO UNITS BELOW MAINS TO BE TAKEN FROM BOTTOM OF MAINS AT A 45 DEGREE ANGLE, PITCH FANS ND OTHER AIR DISTRIBUTION EQUIPMENT OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE . DOWNWARD TOWARD UNITS. BRANCHES TO UNITS ABOVE MAINS TO BE TAKEN FROM TOP OF MAINS AT A 45 At DELIVERED TO TENANT'S PROJECT MANAGER. H. PROPERLY COMPLETED AND SIGNED "SPRINKLER CONTRACTOR'S MATERIAL AND TEST CERTIFICATES" SHALL BE 5. ALL DUCTWORK SHALL BE INSTALLED WITH INSIDE CLEAR DIMENSIONS AS NOTED ON DRAWINGS. WHERE DEGREE ANGLE PITCHED UPWARD TOWARDS UNITS. PITCH NOT LESS THAN 1" TO 10 FEET. FURNISHED TO THE LANDLORD AND AUTHORITIES HAVING JURISDICTION, DUCTWORK SIZE IN LARGER THAN CONNECTED DEVICE SMOOTH DUCT TRANSITIONS SHALL BE INSTALLED JUST REVISIONS SECTION 15008 -DISCREPANCIES IN DOCUMENTS PRIOR TO DEVICE CONNECTION. 3. SEE MECHANICAL DETAIL DRAWINGS FOR APPLICABLE DETAILS. 0 SPECIFICATIONS, AND DETAILS ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION 111 DIVISION 15400 -PLUMBING C. MEDIUM PRESSURE DUCT: 4. PROVIDE UL LISTED FIRE STOPPING SYSTEM AROUND ALL PIPING PENETRATIONS THROUGH RATED WALLS. A. DRAWINGS (PLANS, ) 1. WHERE DUCTWORK IS SPECIFICALLY NOTED AS MEDIUM PRESSURE IT SHALL BE CONSTRUCTED IN ACCORDANCE PENETRATIONS SHALL MEET THE REQUIREMENTS OF UL DETAILS WL1001 UNINSULATED WALL AND INTENT OF THE MECHANICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR SECTION 15401 SUMMARY OF WORK ( ) AND WL5039 OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE TENANT'S PROJECT MANAGER, IN WRITING OF VARIATIONS WITH SMACNA STANDARDS FOR A PRESSURE RATING OF 4 INCHES WATER COLUMN MINIMUM OR LARGER AS (INSULATED WALL). TO CONTRACT DOCUMENTS PRIOR TO SUBMITTAL OF BID. OTHERWISE, TENANT'S PROJECT MANAGER'S REQUIRED BY LANDLORD. A. THIS CONTRACTOR SHALL FURNISH ALL LABOR INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL , MATERIALS, EQUIPMENT, ETC. NECESSARY FOR, REASONABLY 2, ALL GAUGES AND REINFORCEMENT MUST MEET WITH THE LA"FEST EDITION OF SMACNA STANDARDS FOR MEDIUM C. HYDRONIC PIPING INSULATION COMPENSATION PERMITTED. IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR PRESSURE DUCT AND WITH THE LANDLORD'S CRITERIA. THE PLUMBING SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO,3. CONNECTIONS TO THE LANDORD'S MEDIUM PRESSURE DUCTWORK SHALL BE MADE WITH "LO -LOSS" SADDLE TEE 1. ALL HYDRONIC PIPING FOR CHILLED WATER AND/OR HEATING WATER (NOT INCLUDING CONDENSER WATER SECTION 16009 -DEMOLITION INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: TAPS BY UNITED MCGILL CORP., ORAS OTHERWISE REQUIRED BY THE LANDLORD, UNLESS SPECIFICALLY NOTED OTHERWISE), VALVES, FITTINGS, AND ACCESSORIES SHALL BE INSULATED. FOR 4. ALL OTHER ITEMS FROM METAL DUCTWORK SPECIFICATION SECTION APPLY TO THIS SECTION, WITH THE PIPE SIZES UP TO 2 INCHES, INSULATE WITH 1 INCH THICK (K=0.23 @ 75°F) FIBERGLASS INSULATION WITH ALL A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK 1. CONTRACTOR SHALL DETERMINE THE LOCATION OF EXISTING WATER SUPPLY AND DRAIN LINES AND MAKE EXCEPTION THAT ALL MEDIUM PRESSURE DUCTWORK MUST BE WRAPPED INSULATION, NOT LINED. SERVICE JACKET AND VAPOR BARRIER. FOR PIPE SIZES 2-1/2 INCHES AND LARGER, INSULATE WITH 1-1/2 INCH PROPER CONNECTIONS, THERETO, INCLUDING VENTS. THICK K=0 23 75°F FIBERGLASS INSULATION WITH ALL SERVICE JACKET AND VAPOR BARRIER. AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR. COORDINATE WITH THE GENERAL 2, ALL MATERIALS SHALL BE NEW AND SHALL FIT THE SPACE AVAILABLE. VERIFY ALL DIMENSIONS AT THE SITE. ( @ ) D. FLEXIBLE COLLARS AT EQUIPMENT SHALL BE PROVIDED IN ALL CONNECTIONS BETWEEN VIBRATING EQUIPMENT CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. 3. ALL VALVES, CLEANOUTS, ETC. SHALL BE SO LOCATED AND INSTALLED TO PERMIT ACCESS FOR SERVICE DRAWING NUMBER AND DUCTS OR CASINGS. FLEXIBLE CONNECTIONS SHALL CONSTRUCTED OF NEOPRENE -COATED FLAMEPROOF 2. INSULATION AT ALL HANGERS FOR PIPING 21/2 INCHES AND LARGER SHALL BE HARD AND NON-COMPRESSIBLE. B. EACH CONTRACTOR SHLL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL WITHOUT DAMAGE TO BUILDING OR FINISHED MATERIALS: FABRIC, PROVIDE ADEQUATE JOINT FLEXIBILITY TO ALLOW FOR MOVEMENT AND PREVENT THE TRANSMISSION OF EXISTING FIRE PROTECTION, PLUMBING FIXTURES PIPING HVAC UNITS, REFRIGERANT RECAPTURE EXHAUST VIBRATION. 3. ALL INSULATION SHALL HAVE A FLAME SPREAD RATING OF NOT MORE THAN 25 AND A SMOKE DEVELOPED RATING FANS, ETC. AND ASSOCIATED ROOF CURBS NOT BEING REUSED ON THIS PROJECT, UNLESS SPECIFICALLY NOTED SECTION 15402 - MATERIALS OF NO HIGHER THAT 50 TO CONFORM WITH THE REQUIREMENTS OF THE NFPA. 1 OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT, PIPES, E, FLEXIBLE AIR DUCT AT AIR DEVICES SHALL BE MIN. R-5 INSULATED CLASS 1 AND RATED FOR THE OPERATING A. REFER TO PLANS FOR SCHEDULES OF EQUIPMENT AND FIXTURES. AMERICAN STANDARD, KOHLER AND CRANE PRESSURE OF THE SYSTEM. DUCT CONSTRUCTION MATERIAL MUST ADHERE TO LOCAL CODES AND LANDLORD'S 4. PROVIDE ZESTON OR EQUAL INSULATION FITTINGS FOR ALL TEES, ELLS OR SPECIALTY FITTINGS. DUCTWORK, AND EQUIPMENT PRIOR TO REMOVAL. ROOF CURBS SHALL BE REMOVED AND THE ROOF PATCHED. ARE CONSIDERED ACCEPTABLE AS EQUALS. ALL PLUMBING EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE �.', m 3 ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE WITH THE MANUFACTURER'S RECOMMENDATION. REQUIREMENTS. REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED PIPES, DUCTS, OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE ARE TO B. SANITARY PIPING F. PROVIDE MANUAL LOCKING QUADRANT VOLUME CONTROL DAMPERS WITH HANDLE OPERATORS IN EACH BRANCH BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS DUCT AND AS SHOWN ON PLANS TO FACILITATE AIR BALANCING. ALL RECTANGULAR DAMPERS IN OUTSIDE AIR, 8 MECHANICAL PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED PIPING AND/OR DUCTWORK MUST BE REMOVED 1 • WASTE, DRAIN AND VENT PIPING SHALL BE SERVICE WEIGHT CAST IRON HUB AND SPIGOT BELOW; NO HUB ABOVE RELIEF AIR, OR RETURN AIR DUCTS ARE TO BE OF OPPOSED BLADE TYPE. SPECIFICATIONS TO POINT OF ORIGIN. CONFIRM THE EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR AND TENANT GROUND. VENT PIPING ABOVE FLOOR 2" OR SMALLER MAY BE GALVANIZED STEEL. 2. INSULATE ALL HORIZONTAL RUNS OF PIPING LOCATED IN CEILING SPACES OF TENANTS IN SPACES BELOW, WHEN G. PROVIDE PRIMARY FIRE DAMPERS WHERE INDICATED OR REQUIRED BY CODES. FIRE DAMPERS SHALL BE UL PRIOR TO BID AND INCLUDE IN BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND TENANT. APPLICABLE. INSULATION TO BE AS SPECIFIED FOR WATER PIPING. LABELED. FIRE DAMPERS SHALL HAVE THE BLADES OUT OF THE AIRSTREAM AND A 165 F FUSIBLE LINK, TYPE B, 11 ., :.r , e .,,, .. ,,, err , ,. xe,. r<:: , ; „'e .r ,. , , , : > , .. .. , ,,, w,,,,, ,, ,, ,, ,, ,,, , .. ^ ,., ,... .. "''^.3. ^ . .. ^ . „i ,.., .x , < >r" a„ {,: ,, r .. u,,.,,,,', ..Kr,H n.:: rrrrry 5 4, „,.':: , ,r ,. , .....,.... .. . z. r z , r„ , ,., ,u, ,,, ,,,, ,,,,,, ...,...., ,.,,,,,.. ., „ .., a ,. ,., a „uxe ,.,,,.. e,,,, ,e ,,, a ,.R,..,e , ... .,,.�.. ,e <s ,.), .: err r .r e,nv,r.0 v v ,r .,, ,e .. <, ... ^, , a rr x,x ..a : a,f, xxu. ro ,,,, .,„ .:., ,<,,.,.,, ..,,.,,, w .,.. „ ..,, ., , ,,, ,:.. ., „,,,, ^,. ,. .r' 'vt o::: s ., e,. ,, .H:v. r , .., .,, ,..,ct -rir: n v., :':i ;,. ,:: - , .:. . .: e . 1. ... .. rs.. . 11� . : e , .,,.< :: .l < -0 ELECTRICAL COMMENTS: • ABSOLUTELY NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. FLEXIBLE CONDUIT IS PERMITTED FOR SHORT, FINAL CONNECTIONS ONLY (6-0" OR LESS). • EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIHGT LINES, PARALLEL OR IN RIGHT ANGLES TO THE BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE OR WALL CAVITY. • CABLE TYPES AC OR NM CABLES ARE NOT ACCEPTABLE. TYPE MC CABLE, ELECTRIC METALLIC TUBING (EMT), AND RIGID GALVANIZED CONDUIT ARE PERMITTED. • ALL EQUPMENT, DEVICES, AND FIXTURES SHALL BE GROUNDED IN COMPLIANCE WITH NEC AND UL REQUIREMENTS. • ALL PANEL.) TO BE UL LABELED WITH BOLT -ON TYPE CIRCUIT BREAKERS. • 7 -DAY, 24-HOUR TIME CLOCK IS REQUIRED TO CONTROL STOREFRONT ENRTY LIGHTS, SHOW WINDOW, SHOW WINDOW LIGHTS, SHOW WINDOW RECEPTACLES, AND STOREFRONT SIGNAGE. ILLUMINATED STOREFRONT SIGNS MUST REMAIN LIT DURING ALL MALL BUSINESS HOURS. • TENANT IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NT EXCEED THE ELECTRICAL SERVICE. ANY/ALL MODIFICATIONS OR UPGRADES NEEDED ARE SUBJECT TO LANDLORD'S PRIOR APPROVAL, AND WILL BE COMPLETED BY TENANT/TENANT'S G.C., AT TENANT'S SOLE EXPENSE. • ALL ELECTRICAL PANELS TO BE MOUNTED ON PLYWOOD BACKER BOARD. • PANEL PHASE LOADS TO BE BALANCED WITHIN 10%. • ELECTRICAL PANELS MAY NOT BE RECESSED IN DEMISING PARTITIONS. SURFACE MOUNT OR FUR OUT WALL TO ACHIEVE FLUSH APPEARANCE. • ONLY 30KVA AND SMALLER TRANSFORMERS MAY BE SUSPENDED FROM BUILDING STRUCTURE. ALL OTHER TRANSFORMERS NUST BE FLOOR MOUNTED. • FLOOR PENETRATIONS TENANT'S G.C. MUST ADVISE THE PROPERTY'S OPERATIONS DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE CORE -BORED OR SAW -CUT (NO JACK -HAMMERING PERMITTED). PRIOR TO WORK, TENANT'S G.C. MUST VERIFY THAT TENANT'S WORK WILL NOT CONFLICT WITH EXISTING, STRUCTURAL, UTILITY, OR OTHER UNDER SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANT'S EXPENSE. ADJACENT TENANT ..,., .ata ........ ......... ,.. ,, . .. ...,. .,... . ' AA 20,22 { WH -1 .....�" 9 A-10 i LU f n YY aa.w :xi.w\�a\�AA�u3a1Wa ) t A-8 I '- POINT "B" v 1 6 Q!A-1 A-1°'2 13 1I _ ..�. A-4 6 , Es ... a.aaaa 60A DISC:SV — 30KVA XFMR POINT "A" A-1 I POWER PLAN El mOl SCALE: 1/4"=V-0" 14 N)P1 FIRE ALARM SYSTEM SYMBOLS FF—AC-p-1 FIRE CONTROL PANEL +72" A.F.F. TO TOP OF DEVICE I REMOTE POWER SUPPLY +72" A.F.F. TO TOP OF DEVICE i FIRE TERMINAL CABINET FSA FIRE SYSTEM ANUNCIATOR +48" A.F.F. TO TOP OF DEVICE Zc 14 N)P1 VIA`,SjW T- A -12 A 12 +14 . (A-1,) ADJACENT TENANT A-14,16 +18' A-1' m �i A-17 O��...VIA SW f' r, ..�,�.{{,,A 18 I A-1 26+14" ll!! L.1... , E STANDARD 20A, 120/277V-1 O SPST TOGGLE SWITCH MOUNTED AT +48" A.F.F. $OS WALL MOUNTED INFRA -RED OCCUPANCY SENSOR. �S CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR. STANDARD 20A, 120V-10 GROUNDING TYPE SIMPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. (bW.P STANDARD 20A, 120V-10 GROUNDING TYPE WEATHER PROOF (NEMA 3R) DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE CEILING MOUNTED AT STORE FRONT STANDARD 20A, 120V-10 GROUNDING TYPE FOUR-PLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE "GROUND FAULT INTERRUPTER" (G.F.I.) RECEPTACLE MOUNTED AT +'18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE DUPLEX RECEPTACLE,MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE QUADRAPLEX RECEPTACLE, MOUNTED AT+18" A.F.F. STANDARD 15A, 120V-10 SIMPLEX CLOCK RECEPTACLE. La FUSED DISCONNEC-f SWITCH. AMPS, POLES AND FUSE SIZE AS INDICATED. OPEN- INDICATES NON-FUSED W.P. - INDICATES NEMA 3R ENCLOSURE LN COMBINATION DISCONNECT SWITCH/MAGNETIC MOTOR STARTER. AMPS, POLES, FUSE SIZE, AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE. ® MAGNETIC MOTOR STARTER. POLES AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE MANUAL MOTOR STARTER SWITCH. HORSEPOWER RATED -120V - 10 -U.O.N. M PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. O JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND/OR CONDUCTORS PASSING THRU. 10 MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. TRANSFORMER AS SPECIFIED. TIME CLOCK. DELIVERY BUZZER. a DELIVERY BUZZER PUSH BUTTON MOUNTED AT 54" A.F.F. TELEPHONE PLYWOOD BACKBOARD. (1 THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. ]� PROVIDE J -BOX AT +48" A.F.F. (� VOLUME CONTROL MOUNTED AT +48" AFF. `t TELEPHONE OUTLET WITH (1) RJ11 PORT. JACK COLOR- GRAY. XO DATA OUTLET WITH RJ45 PORTS (X) AMOUNT OF DATA PORTS. JACK COLOR - ORANGE. IF COMBINATION TELE/DATA OUTLET WITH (1) RJ11 AND AND (2) RJ45 PORTS. JACK COLOR - GRAY AND ORANGE. ® TELEPHONE OUTLET WITH (1) RJ11 PORT WITH TWO TELEPHONE LINES. JACK COLOR - BLUE. CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. CONDUIT ROUTED BELOW FINISHED GRADE AND / OR CONCRETE SLAB. HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. FLEXIBLE CONDUIT CONNECTION FROM JUNCTION BOX. GENERAL ELECTRICAL SAFETY REQUIREMENTS: A. ALL ELECTRICAL WORK PRACTICES MUST COMPLY WITH APPLICABLE SECTIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL ELECTRICAL CODE (NFPA 70 & 70E), NATIONAL ELECTRICAL SAFETY CODE (NESC) AND STATE AND LOCAL ADOPTED ELECTRICAL CODES. ELECTRICAL N D B. THE GENERAL CONTRACTOR,CTRI AL C CONTRACTOR AN ALL APPLICABLE TRADES ARE RESPONSIBLE FOR STRICT ADHERENCE TO ALL ELECTRICAL SAFETY REQUIREMENTS. LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR CUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. • NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. GENERAL NOT A. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. B. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY, CIRCUITING SHALL BE "THRU-WIRING" WHERE AND WHENEVER POSSIBLE. C. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING ELECTRICAL EQUIPMENT. D. ALL RECEPTACLE CIRCUITS UP TO 100'-0" SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251'-0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. E. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS AND AT 18" A.F.F UNLESS OTHER WISE NOTED). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S PROJECT MANAGER PRIOR TO ROUGH-iN. F. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. G. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. H. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONEY SHALL BE AWARDED FOR TIE-IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. I. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT SWITCH IN LANDLORD'S SWITCH GEAR WITH DEMISED PREMISES' SPACE NUMBER. J. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK.. K. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. L. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH LANDLORD PRIOR TO STARTING WORK. M. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPE WRITTEN PANEL DIRECTORIES IN ALL PANEL BOARDS. N. ALL RECEPTACLES TO BE MOUNTED VERTICALLY, NOT HORIZONTALLY. 0. RECEPTACLE COVER PLATES SHALL BE WHITE EXCEPT AT WAINSCOT, WHERE THEY SHALL BE IVORY P. "G.C. IS TO REVIEW STRUCTURE BELOW OUR SPACE PRIOR TO CONSTRUCTION FOR CONDITIONS PREVENTING FLOOR PENETRATIONS AS SHOWN. OBSTRUCTIONS THAT PREVENT LAYOUT AS SHOWN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY AND PRIOR TO FRAMING." KEYED NOTES: 0 GROSSCOM TO RUN TWO (2) CAT5E WIRES BETWEEN POINTS "A" & "B" BETWEEN POINTS "B" AND "C", AND BETWEEN POINTS "C" AND "A'. COORDINATE ALL ROUTING PRIOR TO ROUGH -IN. 0 PROVIDE RECEPTACLE AT BACK CASH WRAP FOR STEREO EQUIPMENT, VERY EXACT LOCATION WITH OWNER. G.C. TO INSTALL STEREO AND RUN SPEAKER WIRE, G.C. TO RUN WIRE BEHIND FURNITURE, SPEAKERS INSTALLED ON TOP OF FURNITURE TO RIGHT AND LEFT OF BACK CASHWRAP. SPEAKERS TO MUTE WHEN FIRE ALARM IS ACTIVATED. (�,.C. TO VERIFY ALL REQUIREMENTS WITH LANDLORD AND TO COORDINATE WITH FIRE ALARM CONTRACTOR AS REQUIRED. 0DUPLEX RECEPTACLE WITH COVER PLATE MOUNTED IN SOFFIT ABOVE WINDOW. CONTROL RECEPTACLE WITH TIME CLOCK AND SWITCHES AT MANAGER'S DESK. RECEPTACLE AND COVER PLATE TO MATCH SURROUNDING WALL COLOR. �4 NEW PANEL "A" 208Y/120V, 3PH, 4W WITH A 100A MAIN CIRCUIT BREAKER. REFERTO SHEET E-3 FOR MORE DETAIL. 5 NEW TIME CLOCK FOR LIGHTING AND RECEPTACLES. REFER TO SHEET E2 FOR MODEL NUMBER. COORDINATE EXACT LOCATION PRIOR -f0 BID. 2'X 4'X 3/4" TELECOMM. BOARD WITH DEDICATED QUADRAPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE Q COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULL WIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELECOMM. BOARD. VERIFY EXACT LOCATION IN FIELD. SEE SHEET E3 FOR FRANCESCA'S NOTES AND DETAILS. 0 RECEPTACLE, DATA AND TELEPHONE OUTLET MOUNTED IN CASHWRAP MILL WORK. COORDINATE EXACT PLACEMENT OF DEVICE AND WIRE ROUTING IN CASHWRAP WITH MILLWORK DRAWINGS. C) (1) 1" CONDUIT FOR POWER AND (1) 1" CONDUITS FOR TELEPHONE/DATA UNDERFLOOR FROM CASHWRAP TO NEARBY WALL OR COLUMN, UP TO ABOVE CEILING AND TO ELECTRICAL PANEL OR ,TELEPHONE BOARD AS LABELED. STUB CONDUITS UP 16" ABOVE FINISHED FLOOR AT CASHWRAP. SEE E3 FOR FRANCESCA'S NOTES AND DETAILS. ELECTRIC WATER HEATER. CIRCUIT AS SHOWN. 1U PROVIDE WHIP AT 8'-6" AFF FOR FURNITURE. COORDINATE EXACT PLACEMENT OF QUAD RECEPTACLE AND WIRE ROUTING WITH MILLWORK DRAWINGS. SEE SHEET E2. FOR SWITCH LOCATION. 1.� PROVIDE WHIP AT 8'-6" AFF FOR FURNITURE. COORDINATE EXACT PLACEMENT OF DUPLEX RECEPTACLE AND WIRE ROUTING WITH MILLWORK DRAWINGS. MOUNT RECEPTACLE HORIZONTALLY, SEE SHEET E2. FOR SWITCH LOCATION. 12 NEW VAV-1, CIRCUIT AS SHOWN. FIELD VERIFY EXACT CONNECTION REQUIREMENTS PRIOR TO BID. 13 ONE (1) CAT5E LINE ROUTED ABOVE THE CEILING FROM A JUNCTION BOX IN CONDUIT FROM THIS LOCATION TO THE TELEPHONE BOARD. LEAVE 12'-0" OF SLACK AT EACH BOX. COORDINATE JUNCTION BOX LOCATION AND CONDUIT ROUTING PRIOR TO INSTALLATION. 14 NEW 60A, 600V, FUSED DISCONNECT FUSED AT 60A TO FEED NEW 30KVA TRANSFORMER. REFER To ONE -LINE DIAGRAM, SHEET E3 FOR ADDITIONAL INFORMA'HON. 15 NEW 30KVA 48UV-TO-208Y/120V TRANSFORMER. MOUNT TRANSFORMER ON WALL ABOVE PANEL. PARTNERS brand . operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 s ee N �. 0 67023 d 5�.+ • /+_ QVC ���rBd11999ASa�'®e 1 it 6AA �fl `2 ISSUE DATES PRELIM SET: 10-16-2013 x FINAL SET: 11-6-2013 'Y PERMIT SET: 11-20-2013 REVISIONS 1 DRAWING NUMBER I� POWER PLAN ,3 !.v','{1 FIRE ALARM SYSTEM SYMBOLS FF—AC-p-1 FIRE CONTROL PANEL +72" A.F.F. TO TOP OF DEVICE RPS REMOTE POWER SUPPLY +72" A.F.F. TO TOP OF DEVICE F—FT-C-1 FIRE TERMINAL CABINET FSA FIRE SYSTEM ANUNCIATOR +48" A.F.F. TO TOP OF DEVICE Zc CONTROL MODULE Zr RELAY MODULE CONTROL RELAY, SPDT, W/ LED ❑I MONITOR MODULE n PULL STATION +48" A.F.F. TO TOP OF DEVICE Q WATER FLOW SWITCH TS TAMPER SWITCH DH DOOR HOLD OPEN DEVICE 24VDC HORN +90" A.F.F. TO TOP OF DEVICE R1 SUPERVISION RELAY O L DETECTOR 120 VAC W/9VDC BATTERY O PHOTOELECTRIC SENSOR ® HEAT SENSOR W/ RATE -OF -RISE ('7T( DUCT DETECTOR 2 IN -DUCT DETECTOR CD .24VDC AUDIBLE/STROBE UNIT (15CD) +80" A.F.F. TO TOP OF DEVICE (CD=CANDELA) CD 24VDC STROBE UNIT (15CD) +80" A.F.F. TO TOP OF DEVICE (CD=CANDELA) VIA`,SjW T- A -12 A 12 +14 . (A-1,) ADJACENT TENANT A-14,16 +18' A-1' m �i A-17 O��...VIA SW f' r, ..�,�.{{,,A 18 I A-1 26+14" ll!! L.1... , E STANDARD 20A, 120/277V-1 O SPST TOGGLE SWITCH MOUNTED AT +48" A.F.F. $OS WALL MOUNTED INFRA -RED OCCUPANCY SENSOR. �S CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR. STANDARD 20A, 120V-10 GROUNDING TYPE SIMPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. (bW.P STANDARD 20A, 120V-10 GROUNDING TYPE WEATHER PROOF (NEMA 3R) DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE CEILING MOUNTED AT STORE FRONT STANDARD 20A, 120V-10 GROUNDING TYPE FOUR-PLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE "GROUND FAULT INTERRUPTER" (G.F.I.) RECEPTACLE MOUNTED AT +'18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE DUPLEX RECEPTACLE,MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE QUADRAPLEX RECEPTACLE, MOUNTED AT+18" A.F.F. STANDARD 15A, 120V-10 SIMPLEX CLOCK RECEPTACLE. La FUSED DISCONNEC-f SWITCH. AMPS, POLES AND FUSE SIZE AS INDICATED. OPEN- INDICATES NON-FUSED W.P. - INDICATES NEMA 3R ENCLOSURE LN COMBINATION DISCONNECT SWITCH/MAGNETIC MOTOR STARTER. AMPS, POLES, FUSE SIZE, AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE. ® MAGNETIC MOTOR STARTER. POLES AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE MANUAL MOTOR STARTER SWITCH. HORSEPOWER RATED -120V - 10 -U.O.N. M PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. O JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND/OR CONDUCTORS PASSING THRU. 10 MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. TRANSFORMER AS SPECIFIED. TIME CLOCK. DELIVERY BUZZER. a DELIVERY BUZZER PUSH BUTTON MOUNTED AT 54" A.F.F. TELEPHONE PLYWOOD BACKBOARD. (1 THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. ]� PROVIDE J -BOX AT +48" A.F.F. (� VOLUME CONTROL MOUNTED AT +48" AFF. `t TELEPHONE OUTLET WITH (1) RJ11 PORT. JACK COLOR- GRAY. XO DATA OUTLET WITH RJ45 PORTS (X) AMOUNT OF DATA PORTS. JACK COLOR - ORANGE. IF COMBINATION TELE/DATA OUTLET WITH (1) RJ11 AND AND (2) RJ45 PORTS. JACK COLOR - GRAY AND ORANGE. ® TELEPHONE OUTLET WITH (1) RJ11 PORT WITH TWO TELEPHONE LINES. JACK COLOR - BLUE. CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. CONDUIT ROUTED BELOW FINISHED GRADE AND / OR CONCRETE SLAB. HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. FLEXIBLE CONDUIT CONNECTION FROM JUNCTION BOX. GENERAL ELECTRICAL SAFETY REQUIREMENTS: A. ALL ELECTRICAL WORK PRACTICES MUST COMPLY WITH APPLICABLE SECTIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL ELECTRICAL CODE (NFPA 70 & 70E), NATIONAL ELECTRICAL SAFETY CODE (NESC) AND STATE AND LOCAL ADOPTED ELECTRICAL CODES. ELECTRICAL N D B. THE GENERAL CONTRACTOR,CTRI AL C CONTRACTOR AN ALL APPLICABLE TRADES ARE RESPONSIBLE FOR STRICT ADHERENCE TO ALL ELECTRICAL SAFETY REQUIREMENTS. LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR CUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. • NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. GENERAL NOT A. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. B. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR CLARITY, CIRCUITING SHALL BE "THRU-WIRING" WHERE AND WHENEVER POSSIBLE. C. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING ELECTRICAL EQUIPMENT. D. ALL RECEPTACLE CIRCUITS UP TO 100'-0" SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251'-0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. E. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT TO CORNERS AND AT 18" A.F.F UNLESS OTHER WISE NOTED). IF THE RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S PROJECT MANAGER PRIOR TO ROUGH-iN. F. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. G. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. H. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONEY SHALL BE AWARDED FOR TIE-IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. I. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT SWITCH IN LANDLORD'S SWITCH GEAR WITH DEMISED PREMISES' SPACE NUMBER. J. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK.. K. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. L. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH LANDLORD PRIOR TO STARTING WORK. M. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPE WRITTEN PANEL DIRECTORIES IN ALL PANEL BOARDS. N. ALL RECEPTACLES TO BE MOUNTED VERTICALLY, NOT HORIZONTALLY. 0. RECEPTACLE COVER PLATES SHALL BE WHITE EXCEPT AT WAINSCOT, WHERE THEY SHALL BE IVORY P. "G.C. IS TO REVIEW STRUCTURE BELOW OUR SPACE PRIOR TO CONSTRUCTION FOR CONDITIONS PREVENTING FLOOR PENETRATIONS AS SHOWN. OBSTRUCTIONS THAT PREVENT LAYOUT AS SHOWN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY AND PRIOR TO FRAMING." KEYED NOTES: 0 GROSSCOM TO RUN TWO (2) CAT5E WIRES BETWEEN POINTS "A" & "B" BETWEEN POINTS "B" AND "C", AND BETWEEN POINTS "C" AND "A'. COORDINATE ALL ROUTING PRIOR TO ROUGH -IN. 0 PROVIDE RECEPTACLE AT BACK CASH WRAP FOR STEREO EQUIPMENT, VERY EXACT LOCATION WITH OWNER. G.C. TO INSTALL STEREO AND RUN SPEAKER WIRE, G.C. TO RUN WIRE BEHIND FURNITURE, SPEAKERS INSTALLED ON TOP OF FURNITURE TO RIGHT AND LEFT OF BACK CASHWRAP. SPEAKERS TO MUTE WHEN FIRE ALARM IS ACTIVATED. (�,.C. TO VERIFY ALL REQUIREMENTS WITH LANDLORD AND TO COORDINATE WITH FIRE ALARM CONTRACTOR AS REQUIRED. 0DUPLEX RECEPTACLE WITH COVER PLATE MOUNTED IN SOFFIT ABOVE WINDOW. CONTROL RECEPTACLE WITH TIME CLOCK AND SWITCHES AT MANAGER'S DESK. RECEPTACLE AND COVER PLATE TO MATCH SURROUNDING WALL COLOR. �4 NEW PANEL "A" 208Y/120V, 3PH, 4W WITH A 100A MAIN CIRCUIT BREAKER. REFERTO SHEET E-3 FOR MORE DETAIL. 5 NEW TIME CLOCK FOR LIGHTING AND RECEPTACLES. REFER TO SHEET E2 FOR MODEL NUMBER. COORDINATE EXACT LOCATION PRIOR -f0 BID. 2'X 4'X 3/4" TELECOMM. BOARD WITH DEDICATED QUADRAPLEX RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM GROUNDING AND ALL OTHER REQUIREMENTS WITH LOCAL TELEPHONE Q COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULL WIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELECOMM. BOARD. VERIFY EXACT LOCATION IN FIELD. SEE SHEET E3 FOR FRANCESCA'S NOTES AND DETAILS. 0 RECEPTACLE, DATA AND TELEPHONE OUTLET MOUNTED IN CASHWRAP MILL WORK. COORDINATE EXACT PLACEMENT OF DEVICE AND WIRE ROUTING IN CASHWRAP WITH MILLWORK DRAWINGS. C) (1) 1" CONDUIT FOR POWER AND (1) 1" CONDUITS FOR TELEPHONE/DATA UNDERFLOOR FROM CASHWRAP TO NEARBY WALL OR COLUMN, UP TO ABOVE CEILING AND TO ELECTRICAL PANEL OR ,TELEPHONE BOARD AS LABELED. STUB CONDUITS UP 16" ABOVE FINISHED FLOOR AT CASHWRAP. SEE E3 FOR FRANCESCA'S NOTES AND DETAILS. ELECTRIC WATER HEATER. CIRCUIT AS SHOWN. 1U PROVIDE WHIP AT 8'-6" AFF FOR FURNITURE. COORDINATE EXACT PLACEMENT OF QUAD RECEPTACLE AND WIRE ROUTING WITH MILLWORK DRAWINGS. SEE SHEET E2. FOR SWITCH LOCATION. 1.� PROVIDE WHIP AT 8'-6" AFF FOR FURNITURE. COORDINATE EXACT PLACEMENT OF DUPLEX RECEPTACLE AND WIRE ROUTING WITH MILLWORK DRAWINGS. MOUNT RECEPTACLE HORIZONTALLY, SEE SHEET E2. FOR SWITCH LOCATION. 12 NEW VAV-1, CIRCUIT AS SHOWN. FIELD VERIFY EXACT CONNECTION REQUIREMENTS PRIOR TO BID. 13 ONE (1) CAT5E LINE ROUTED ABOVE THE CEILING FROM A JUNCTION BOX IN CONDUIT FROM THIS LOCATION TO THE TELEPHONE BOARD. LEAVE 12'-0" OF SLACK AT EACH BOX. COORDINATE JUNCTION BOX LOCATION AND CONDUIT ROUTING PRIOR TO INSTALLATION. 14 NEW 60A, 600V, FUSED DISCONNECT FUSED AT 60A TO FEED NEW 30KVA TRANSFORMER. REFER To ONE -LINE DIAGRAM, SHEET E3 FOR ADDITIONAL INFORMA'HON. 15 NEW 30KVA 48UV-TO-208Y/120V TRANSFORMER. MOUNT TRANSFORMER ON WALL ABOVE PANEL. PARTNERS brand . operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE#1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 s ee N �. 0 67023 d 5�.+ • /+_ QVC ���rBd11999ASa�'®e 1 it 6AA �fl `2 ISSUE DATES PRELIM SET: 10-16-2013 x FINAL SET: 11-6-2013 'Y PERMIT SET: 11-20-2013 REVISIONS 1 DRAWING NUMBER I� POWER PLAN ,3 !.v','{1 ADJACENT TENANT' Y p { s F a 1 CO C -CO 1 a C ! E a. ....v ® . I.,. DW(4) .. ........,.. CCa I E $ 3 E � � a I i 1 q IA A A A-19 T(IR 4 -011 ' ... .,,u SW "h'I 2 1 0S D rtm�emim" E 8 -0 jJF A, iii z ! ! I n I QW(5) DW 5; A1b F 18'-0" } IX4 _ ) I DW 5 L! ! ]j u! , I f f g� F ? Q Q A-15 1 E THRU; SWITCH 'V'i 41E , I s E n 5 p n , X7 B -CO 5 ..,a A- d 3 3 s X QW U4 1 A-1aE -..........0 11 LIGHTING FIXTURE SCHEDULE SYMBOL DESCRIPTION MANUFACTURER MODEL NUMBER LAMP WATTAGE VOLTS MOUNTING FURNISHED BY 2. 6" RECESSED NEW CONSTRUCTION LED DOWNLIGHT ON A-18 "THRU-WIRING" WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT A-19 FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE SALES ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU-WIRING". SALES A SALES FLOOR. 1000 LUMEN, 90+ CRI, 3000K, WITH WHITE DMF #DLE16/DM10930-L60W LED INCLUDED 15 120V RECESSED FRANCESCA'S FURNITURE ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. ROOM LIGHT FIXTURE SPECIFICATION MAY VARY. IF CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR IS LIGHTS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH TENANT'S LIGHTING SUPPLIER. .5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL COLLECTIONS ELECTRIC CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL METAL TRIM VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). CLOSELY COORDINATE INSTALLATION WITH TENANT'S CONSTRUCTION MANAGER. 6. ALL LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM '101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTS PEY'I"ON SAL -SPRAY COLLECTION 6+3 LIGHT CIRCUITS ABOVE 251'-0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. MARTEK (9) ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY CHAIN HUNG @ 7'-6" FRANCESCA'S B -GO CHANDELIER IN WHITE FINISH MURRAY-FIESS #F2534/6+3WH #nLED-JFF-2700K-DIM-ALU 32 120V AFF COLLECTIONS CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 9. EXIT/EMERGENCY LIGHTS AT STOREFRONT ARE TO BE CEILING MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.0). EXIT/EMERGENCY LIGHTS AT DOOR TO "NON -SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH TENANTS C -CO PEYTON SALTSPRAY COLLECTION 1 LIGHT WALL SCONCE MURRAY FIESS #WB1486SGW SATCO 60 120V WALL MOUNTED FRANCESCA'S IN WHITE FINISH (1) 601310/F -130V COLLECTIONS DW WHITE PAR38 FRONTLOAD GIMBAL TRACK HEAD NORA #NTH -148W MSI (1) XPAR383025114TN 14 120V TRACK MOUNTED FRANCESCA'S COLLECTIONS D -TW WHITE 8'1 CIRCUIT TRACK. CONTACTOR TO FIELD CUT NORA #NT -304W - 120V TRACK MOUNTED FRANCESCA'S TO LENGTH COLLECTIONS USHIO E BATHROOM FAN/LIGHT COMBO IN WHITE FINISH, 110CFM CRAFTMADE #TV110SL (2) CF18DE/835 39 120V SURFACE FRANCESCA'S (INCLUDED) COLLECTIONS 4FT TWO LAMP SURFACE MOUNTED WRAP AROUND USHIO ELECTRICAL F FIXTURE FOR STOCKROOM COLUMBIA #WC4 232 -EU (2) #F32 -F8/83058 120V SURFACE CONTRACTOR PUBLIC AREA LED EDGE LIT EXIT SIGN CEILING/WALL X1 SURFACE MOUNT WITH RED LETTERING ON CLEAR BACK BEST #ELXTEUI RCAEM INCLUDED - 120V SEE PLAN - MOUNT ON FRANCESCA'S GROUND, SILVER FINISH, AND EMERGENCY BATTERY WALL OR CEILING COLLECTIONS BACK OF HOUSE LED PLASTIC EMERGENCY/EXIT COMBO X3 SIGN CEILING/WALL SURFACE NOUN WITH RED BEST #CXTEU2RW INCLUDED - 120V SEE PLAN - MOUNT ON FRANCESCA'S LETTERING, WHITE FINISH, AND EMERGENCY BATTERY WALL OR CEILING COLLECTIONS PUBLIC AREA EMERGENCY BUG EYE FIXTURE WITH X4 STANDARD LUMEN 5AW MR16 LAMPS IN A WHITE FINISH. BEST #RMR-16 (2) 5AW MR16 FLOOD - 120V SEE PLAN - MOUNT ON FRANCESCA'S FOR USE IN CEILINGS/WALLS 12FT AND UNDER LAMPS INCLUDED WALL OR CEILING COLLECTIONS 125W 120V EMERGENCY POWER INVERTER WITH FRANCESCA'S X7 SWITCHABLE INPUT. WILL SUPPORT UP TO 8 ISOLITE #IMI -125 -LC -VI -TB - 125 120V SURFACE(WALL) COLLECTIONS DOWNLIGHTS. NOTE: ALL FIXTURES INDICATED AS EMERGENCY (EM OR SHADED) SHALL BE PROVIDED WITH EMERGENCY BATTERY PACKS. BATTERY PACKS SHALL BE AS FOLLOWS: - LINEAR T8 FLUORESCENT LAM PS -BOD INE#B50/1350 LUMENS MINIMUM -2/1 LAMP OPERATION - COMPACT FLUORESCENT LAMPS-BODINE#B84C/1000 LUMENS MINIMUM -2/1 LAMP OPERATION. - COMBINATION TEST SWITCH/CHARGE LIGHT. ALTERNATE OR EQUALS TO BE PRE -APPROVED BY ARCHITECT AND ELECTRICAL ENGINEER. PROVIDE EMERGENCY REFLECTORS OR HOUSINGS WHEN OPTION IS AVAILABLE FROM MANUFACTURER TO ALLOW FOR INSTALLATION OF BATTERY PACKS, TEST SWITCHES, PILOT LIGHTS, ETC. WITHIN FIXTURE. WHEN OPTIONAL EMERGENCY REFLECTORS OR HOUSINGS ARE NOT AVAILABLE, REMOTE BATTERY PACKS, TEST SWITCHES, PILOT LIGHTS, ETC. ARE TO BE INSTALLED IN THE MOST CONSPICUOUS LOCATION AS ALLOWED BY CODE AND LOCAL AHJ REQUIREMENTS. IF NECESSARY, COORDINATE LOCATION WITH ARCHITECT AND/OR ELECTRICAL ENGINEER PRIOR TO ANY ROUGH -IN. ADJACENT TENANT' Y p { s F a 1 CO C -CO 1 a C ! E a. ....v ® . I.,. DW(4) .. ........,.. CCa I E $ 3 E � � a I i 1 q IA A A A-19 T(IR 4 -011 ' ... .,,u SW "h'I 2 1 0S D rtm�emim" E 8 -0 jJF A, iii z ! ! I n I QW(5) DW 5; A1b F 18'-0" } IX4 _ ) I DW 5 L! ! ]j u! , I f f g� F ? Q Q A-15 1 E THRU; SWITCH 'V'i 41E , I s E n 5 p n , X7 B -CO 5 ..,a A- d 3 3 s X QW U4 1 A-1aE -..........0 11 LIGHTING PLAN E2m01 SCALE: 1/4"=1'-0" F 8'0" I A-7 THRU SWITCH .,.,.,.,... .. j E i i x s .. A' I 1 DW(4) $. -.O 6'-0.. : { , r Ij 2 'A_1 b If P' A-1 s I1x �d 1. X1 � E , A ' , ' > ,. I I � 3.s Q� `I � I��`• . -1a � a1 4 F p• -Alb', a 1 , 3 AQ DW(4) 4 ` A-1 b 15 6 0" ��i\\' DW(3) w..N,. D...5 4,,0113. _I $, "N �.�. 7 ZZ-1-99Ly =^" 1 'QW(3) A-3 )THRU I ` a— A-13 THRU TIMECLOCK LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR GUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. NOTE TO BIDDERS/CONTRACTOR THESE DRAWINGS WERE PREPARED AS ACCURATELY AS POSSIBLE UTILIZING EXISTING DRAWINGS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE BIDDING AND COMMENCEMENT OF THE PROJECT. CLAIMS FOR EXTRAS RESULT FROM LACK OF COMPLIANCE WILL BE DENIED. GENERAL NOT S: 1. I E ! 2 s LIGHTING PLAN E2m01 SCALE: 1/4"=1'-0" F 8'0" I A-7 THRU SWITCH .,.,.,.,... .. j E i i x s .. A' I 1 DW(4) $. -.O 6'-0.. : { , r Ij 2 'A_1 b If P' A-1 s I1x �d 1. X1 � E , A ' , ' > ,. I I � 3.s Q� `I � I��`• . -1a � a1 4 F p• -Alb', a 1 , 3 AQ DW(4) 4 ` A-1 b 15 6 0" ��i\\' DW(3) w..N,. D...5 4,,0113. _I $, "N �.�. 7 ZZ-1-99Ly =^" 1 'QW(3) A-3 )THRU I ` a— A-13 THRU TIMECLOCK LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR GUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. NOTE TO BIDDERS/CONTRACTOR THESE DRAWINGS WERE PREPARED AS ACCURATELY AS POSSIBLE UTILIZING EXISTING DRAWINGS. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO FIELD VERIFY EXISTING CONDITIONS PRIOR TO THE BIDDING AND COMMENCEMENT OF THE PROJECT. CLAIMS FOR EXTRAS RESULT FROM LACK OF COMPLIANCE WILL BE DENIED. GENERAL NOT S: 1. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS 2 WORK AND THE WORK OF ALL SUBCONTRACTORS WITH ALL DIVISION OF WC)HK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS WITH A COMPLETE SET OF OE.C. BID DOCUMENTS. 2. LIGHTING SHALL BE CIRCUITED EXACTLY AS SHOWN ON PLANS. CIRCUITING SHALL BE A-18 "THRU-WIRING" WHERE AND WHENEVER POSSIBLE. MULTIPLE CONNECTIONS TO A SINGLE LIGHT A-19 FIXTURE FOR VOLTAGE DROP CONDITIONS OR AS A RESULT OF A FIELD CONDITION ARE SALES ACCEPTABLE. LIGHTING FIXTURES SHALL BE MANUFACTURED TO ACCOMMODATE "THRU-WIRING". SALES ANY RELATED COSTS FOR MULTIPLE CONNECTIONS SHALL BE INCLUDED IN BID. 3. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION AND QUANTITY OF LIGHTING CHANGING FIXTURES. 4. ELECTRICAL CONTRACTOR'S BID SHALL INCLUDE THE INSTALLATION OF ALL LIGHT FIXTURES AND DECORATIVE ASSOCIATED LAMPS FURNISHED BY TENANT. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO FURNITURE ENSURE THE ADJUSTABILITY OF ALL DIRECTIONAL FIXTURES AFTER INSTALLATION AND AIM THEM. ROOM LIGHT FIXTURE SPECIFICATION MAY VARY. IF CEILING SYSTEMS ARE FIRE RATED, CONTRACTOR IS LIGHTS TO CLOSELY COORDINATE FIXTURE REQUIREMENTS WITH TENANT'S LIGHTING SUPPLIER. .5. EMERGENCY AND EXIT LIGHTS SHALL BE INSTALLED AND CIRCUITED PER THE LATEST NATIONAL LIGHTS ELECTRIC CODE AND ALL LOCAL CODES. ALL EMERGENCY AND EXIT FIXTURES SHALL BE DUAL GENERAL VOLTAGE WITH BATTERY BACKUP (120/277 VOLT INPUT). CLOSELY COORDINATE INSTALLATION WITH TENANT'S CONSTRUCTION MANAGER. 6. ALL LIGHTING CIRCUITS UP TO 100'-0" IN LENGTH SHALL UTILIZE #12 CONDUCTORS MINIMUM. ALL LIGHTING CIRCUITS FROM '101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. LIGHTS ALL LIGHTING CIRCUITS FROM 150'-0" TO 250'-0" IN LENGTH SHALL UTILIZE #8 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251'-0" SHALL UTILIZE #6 CONDUCTORS MINIMUM. 7. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. 8. WHERE DRY WALL CEILINGS ARE USED IN THE "SALES" AREA, THE ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATION. THE USE OF JUNCTION BOXES ABOVE DRY WALL CEILINGS SHALL BE LIMITED TO LOCATIONS NEAR ACCESS FRAMES USED FOR DIFFUSERS AND RETURN AIR GRILLES OR ACCESS PANELS AS LOCATED ON PLANS. FIELD COORDINATE WITH TENANT'S PROJECT MANAGER PRIOR TO ROUGH -IN TO AVOID ANY CONFLICTS. JUNCTION BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. 9. EXIT/EMERGENCY LIGHTS AT STOREFRONT ARE TO BE CEILING MOUNTED AND CENTERED OVER OPENING (TYPICAL U.N.0). EXIT/EMERGENCY LIGHTS AT DOOR TO "NON -SALES" SHALL BE CENTERED ON WALL ABOVE DOOR. FIELD VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH TENANTS CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. 10. ELECTRICAL CONTRACTOR TO FURNISH AND INSTALL A POLY PULL STRING IN ALL EMPTY CONDUITS N CONFIGURATION FOR FUTURE USE. SECURE PULL STRING AT BOTH ENDS OF CONDUIT. KEYED NOTES: 1 PROVIDE JUNCTION BOX WITH DISCONNECT SWITCH IN CONCEALED LOCATION FOR CONNECTION TO STORE FRONT SIGN LIGHTING. LOCATE DISCONNECT PER NEC 600.6 2 CIRCUIT NIGHT, EMERGENCY, AND EXIT LIGHTING FIXTURES AHEAD OF CONTROLS. PROVIDE NEW BALLAST AS REQUIRED. OE.C. TO PROVIDE CURRENT -LIMITING BREAKER AT END OF TRACK. A-5 REFER TO SWITCH BANK DETAIL, THIS SHEET, FOR LIGHTING CONTROLS FOR THE SPACE. A-18 CONNECT LIGHT TO EMERGENCY INVERTER'X8' FOR EMERGENCY LIGHTING IN THIS SPACE. E2mO3 SWITCH BANK SCALE: NTS. TIME CLOCK: TORK #1847AW, OR 'ALF -NT BY PARAGON. E, 20 AMP, 600V., MECHANICALLY HELD 1NG CONTACTOR WITH 2 -WIRE CONTROL ( AND 120V AC COIL - SQUARE D CLASS _X SERIES OR EQUAL. BLEARING CONTACTS (SUPPLIED) i UNLATCH i A-13 i i I SIGN ` SPARE I� j SPARE SPARE SPARE E ` LIGHTING CONTROLS DIAGRAM E2"02 SCALE: N.T.S. IWPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ISSUE DATES PRELIM SET: 10-16-2013 �� FINAL SET: 11-6-2013 © PERMIT SET: 11-20-2013 REVISIONS LIGHTING PLAN lf:e!'I i'IjYI ,. .. ,.. ... .. i.. .. ;.. :. r..: ,.�.. ... .... .... .. ... .. :... ..", ,. ,.. :� .:.� �,.. .. A-1 A-1 A-3 A-5 A-15 A-18 A-% A-19 SALES SALES SALES SALES BACK SALES SALES CHANGING GENERAL GENERAL DISPLAY DECORATIVE ROOM FURNITURE DISPLAY ROOM LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS GENERAL LIGHTS NOTE:- T F CONTRACTOR O VERIFY E I Y XA T E C N CONFIGURATION REQUIRED WITH H SPACE AVAILABLE. PROVIDE LABELS AS DIRECTED BY OWNER. SWITCHES SHALL NOT BE MOUNTED HIGHER THAN 48". E2mO3 SWITCH BANK SCALE: NTS. TIME CLOCK: TORK #1847AW, OR 'ALF -NT BY PARAGON. E, 20 AMP, 600V., MECHANICALLY HELD 1NG CONTACTOR WITH 2 -WIRE CONTROL ( AND 120V AC COIL - SQUARE D CLASS _X SERIES OR EQUAL. BLEARING CONTACTS (SUPPLIED) i UNLATCH i A-13 i i I SIGN ` SPARE I� j SPARE SPARE SPARE E ` LIGHTING CONTROLS DIAGRAM E2"02 SCALE: N.T.S. IWPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ISSUE DATES PRELIM SET: 10-16-2013 �� FINAL SET: 11-6-2013 © PERMIT SET: 11-20-2013 REVISIONS LIGHTING PLAN lf:e!'I i'IjYI ,. .. ,.. ... .. i.. .. ;.. :. r..: ,.�.. ... .... .... .. ... .. :... ..", ,. ,.. :� .:.� �,.. .. A-1 A-1 A-3 A-5 A-15 A-18 A-% A-19 SALES SALES SALES SALES BACK SALES SALES CHANGING GENERAL GENERAL DISPLAY DECORATIVE ROOM FURNITURE DISPLAY ROOM LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS LIGHTS GENERAL LIGHTS E2mO3 SWITCH BANK SCALE: NTS. TIME CLOCK: TORK #1847AW, OR 'ALF -NT BY PARAGON. E, 20 AMP, 600V., MECHANICALLY HELD 1NG CONTACTOR WITH 2 -WIRE CONTROL ( AND 120V AC COIL - SQUARE D CLASS _X SERIES OR EQUAL. BLEARING CONTACTS (SUPPLIED) i UNLATCH i A-13 i i I SIGN ` SPARE I� j SPARE SPARE SPARE E ` LIGHTING CONTROLS DIAGRAM E2"02 SCALE: N.T.S. IWPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #1311C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ISSUE DATES PRELIM SET: 10-16-2013 �� FINAL SET: 11-6-2013 © PERMIT SET: 11-20-2013 REVISIONS LIGHTING PLAN lf:e!'I i'IjYI ,. .. ,.. ... .. i.. .. ;.. :. r..: ,.�.. ... .... .... .. ... .. :... ..", ,. ,.. :� .:.� �,.. .. NEC ELECTRICAL LOAD SUMMARY SIZE: 100 AMP MCB FEEDER: # 3 W/#8 G IN 11/4" C CU SETS: 1 OPTIONS: NONE NEMA: 1 ELECTRICAL LOAD MOUNTING: SURFACE VOLTAGE: 208Y/120V CONFIG: 3 PHASE 4 WIRE NEUTRAL: 100% TVSS: NO CONNECTED NEC DEMAND USE NEC REFERENCE LIGHTING ZONE -L1 VA/FT2 0.00 730 913 KW PER PHASE 220.12,42 LIGHTING ZONE -1_2 VA/FT2 0.00 0 0 U) w a 220.12,42 LIGHTING ZONE -L3 VA/FT2 0.00 0 0 220.12,42 TRACK - TL (FT) 96 952 6,840 220.43(B) SIGNS - S (EA) 1 1,000 1,250 � 220.14(F) SHOW WINDOW - SW (FT) RATING _ 0 0 220.14(G),43(A) DF = DIVERSITY FAC TOR RECEPTACLES - R 3,780 3,780 100% 220.14(H,I & K),44 KITCHEN RESISTIVE - KR 2,100 2,100 _ 100%u 220.56 KITCHEN MOTORS - KM 0 0 100% 220.56 COOLING MOTORS - C 0 0 100% 220.40,50,60 HEATING - H 0 0 _ 100% 220.40,50,51,60 OTHER MOTORS - OM MAX MOTOR HP 0 0 N/A 0 0 100% 220.40,50 220.40,50 WATER HEATERS - WH 4,160 4,160 100% 220.40 OTHER - 0 100 100 100% 220.40 LTG - SALES TRACK j--- 0.43 ` ` TOTAL KW 12.8 19.1 POWER FACTOR: 99% LIGHTING AREA - Al 5.0 FT2 LIGHTING - L1 0.00 W/FT2 LIGHTING AREA - A2 20 FT2 _i LIGHTING - L2 0.00 W/FT2 LIGHTING AREA - A3 FT2 LIGHTING - L3 0.00 W/FT2 LIGHTING AREA 0 FT2 TOTAL LIGHTS: 0.00 W/FT2 COOLING AREA 0 FT2 COOLING - C 0.00 W/FT2 HEATING AREA CONNECTED: 0 0.00 FT2 HEATING - H W/FT2 NEC DEMAND: 0.00 W/FT2 0.00 W/FT2 SYSTEM VOLTAGE; 480 VOLTS PHASES: 3 CONNECTED: 15.6 AMPS NEC DEMAND: 23.3 AMPS MOTOR CONTRIBUTION: 0.0 KW CONFIGURATION: 3 PHASE 4 WIRE �= PANELBOARD: A SIZE: 100 AMP MCB FEEDER: # 3 W/#8 G IN 11/4" C CU SETS: 1 OPTIONS: NONE NEMA: 1 SERVICE ENTRANCE: NO LENGTH: 50 FT CCNDUIT TYPE: ST TYPE: LIGHTING & APPLIANCE VOLTAGE DROP: 0.37% MOUNTING: SURFACE VOLTAGE: 208Y/120V CONFIG: 3 PHASE 4 WIRE NEUTRAL: 100% TVSS: NO LOCATION: ELECTRIC ROOM FED FROM: DP DIRECTION: TOP BRANCH MOUNT: BOLT -ON BUS MATERIAL: CU CIRCUIT OC w co a w a w o DESCRIPTION KW PER PHASE KW PER PHASE DESCRIPTION o 0 U) w a OC CIRCUIT N0. RATING a z 2-1 � ¢ a RATING NO. q g C A B C 1 20 1 2.1 L1 LTG - SALES 0.25 ' - 0.36 -- RECEPT. - MGR'S DESK R 3.0 1 20 2 3 20 1 3.8 TL LTG - SALES TRACK j--- 0.43 ` ` 0.60 ` - REFRIGERATOR KR 5.0 1 ZO 4 5 20 1 1.9 L1 LTG - DECORATIVE ' .21 __ _ 1.50 MICROWAVE KR _ 12.5 1 20 6 7 20 1 4.5 TL LTG - SALES TRACK 0.52 0.36 -_ -__ RECEPT. - PHONE BOARD R 3.0 1 20 8 9 20 1 SPARE - -__ ___ 0.54 >< RECEPT. - BOH R _ 4.5 1 20 10 11 20 1 1.5 R RECEPT. - BACKWRAP `' - -_ 0.18 - -__ 0.72 RECEPT. - SALES T R 6.0 1 20 12 13 20 1 8.8 S STOREFRONT SIGN 1.00 -__ '` ___ 0.18 _ i RECEPT. - CASHWRAP R 1.5 1 20 14 15 20 2.0 L1 LTG - BOH ` -__ 0.18 ` -- 1 20 1 0.22 RECEPT. - CASHWRAP R 1.5 16 20 1 4.5 R RECEPT. - STOREFRONT - 0.54 �' ` 0.72 RECEPT. - FURNITURE R 6.0 1 20 18 r2l 20 1 0.4 L1T LTG - FITTING ROOM 0.05 jam �' '� 2.08 '` ` WATER HEATER WH 20.0 _ 2 30 20 SPARE \ 2.08 WATER HEATER WH 20.0 2 30 22 23 SPARE. -_ �. 0.10 VAV-1 0 0.8 1 20 24 25 SPARE _ !� SPARE 26 27 SPARE _ SPARE 28 29 _ SPARE f. SPARE 30 GROUND: SOLID DIVERSITY: 105% 4.8 KW -A 4.1 KW -B 4.0 KW -C SCCR: 42 kAIC BALANCE: 87% CONNECTED: 12.8 KW 36.0 AMPS SPEC. SECTION 262416 PF: 99% DEMAND: 13.5 KW 37.9 AMPS TYPE: H -HEATING, C -COOLING, KR -KITCHEN RESISTIVE, KM -KITCHEN MOTOR, WH -WATER HEATER, OM -OTHER MOTOR, L1,L2 OR 1 -3 -LIGHTING, TL -TRACK LIGHTING, S -SIGNS, SW-SHUVV WINUUW, R -RECEPTACLES, SF -SUB FEED, 0 -OTHER, E-EXISITNG SIZE: MLO -MAIN 1.UG ONLY, MCB-MAIN CIRCUIT BREAKER NOTE: GF -GROUND FAULT, AF -ARC FAULT, E -EXISTING TC -VIA TIME CLOCK, ST -SHUNT TRIP, LC -LOCK ON, PC -PHOTO CELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL•FEED THRU LUGS (2) #1 A-24 " "' EEDER (3) #6 & 3ND IN 1 "C BY E.C. UIJI.rui\wiLki I JVVI I url WITH 60A FUSES. ONE -LINE DIAGRAM E3.01 SCALE: N.T.S. NEW 60A, 3 -POLE DISCONNECT SWITCH WITH 60A FUSES. I I I-LANDLORD'S EXISTING 480Y/277V, 3 -PH, 4W DISTRIBUTION PANEL GENERAL NOTE: A. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. B. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 1993 (OR LA -TEST ADOPTED) NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. C. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ELECTRICAL REQUIREMENTS OF ALL EQUIPMENT PROVIDED BY OTHERS (INCLUDING HVAC EQUIPMENT) PRIOR TO ROUGH -IN AND PROVIDE ALL REQUIRED FUSIBLE SWITCHES, TRANSFORMERS, STARTERS NECESSARY FOR PROPER OPERATION OF EQUIPMENT. E. DUPLEX RECEPTACLES MOUNTED WITHIN 6FT. OF SINK TO BE A GFI RECEPTACLE. F. ALL WIRING SHALL BE COPPER, THHN/THWN OR XHHW INSULATED IN CONDUIT. MINIMUM CONDUIT SIZE TO BE 1/2". PROVIDE INSULATED COPPER BOND WIRE ON ALL CIRCUITS. G. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHT FIXTURES. VERIFY CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMMODATE LIGHT FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. H. ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING AUTHORITY. ACCESSIBLE NOTE: LIGHT SWITCHES, ELECTRICAL OUTLETS, -THERMOSTATS AND OTHER ENVIRONMENTAL CONTROLS SHALL HAVE OPERABLE PARTS OF THE CONTROLS LOCATED NO HIGHER THAN 48" AND NO LOWER THAN 15" ABOVE THE FLOOR. IF THE REACH IS OVER AN OBSTRUCTION BETWEEN 20" AND 25" IN DEPTH. THE MAXIMUM HEIGHT IS REDUCED -TO 44" FOR FORWARD APPROACH OR 46" FOR SIDE APPROACH, PROVIDED THE OBSTRUCTION IS NO MORE THAN 24" IN DEPTH. OBSTRUCTIONS SHALL NOT EXTEND MORE'THAN 25" FROM'THE WALL BENEATH A CONTROL, LANDLORD REQUIREMENTS: • PRIOR TO BID, TENANT IS REQUIRED TO VERIFY THAT -THE LANDLORD'S EXISTING AVAILABLE ELECTRICAL SERVICE MEETS THE TENANTS TOTAL CONNECTED LOAD. • TGC TO SURVEY ALL EXISTING ELECTRICAL EQUIPMENT AND VERIFY ANY ADDITIONAL LANDLORD WORK TO BE COMPLETED. VERIFY WITH MALL OPERATIONS. • COORDINATE ALL NEW ROUTING OF CONDUIT, FEEDER CABLES, AND CONNECTIONS TO LANDLORD'S MAIN ELECTRICAL GEAR WITH MALL OPERATIONS.. • ANY AND ALL UPGRADES TO EXISTING EQUIPMENT SHALL BE AT TGC AT TENANTS EXPENSE. mdPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OH 43017 614.634.7000 T WDPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #R11 C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 Ova ®.4e ff D S• K C E /VSA°. �<j No 67p23 O °o905 tl. 4 e;...., �,o9ZONAL e" fid, I I I M 11110 NOV 2 0 20J3 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS All DRAWING NUMBER ELEC. RISER & SCHEDULES u., - - x :;'.:. '.�} a +...e.,r.. .., ,.�. ': ...., ., ...41 r7 :.: :�, Y.yt,, r> •.. ., is '.; Y', r.. >..r ,.�:.. >.e '.S ..4 xn .... ., . , ., . I r' � DIVISION 16000 - ELECTRICAL SECTION 16001 - BASIC ELECTRICAL REQUIREMENTS A. GENERAL CONDITIONS 1. DRAWINGS AND GENERAL PROVISIONS OF CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND ALL OTHER SPECIFICATION SECTIONS, APPLY TO THIS AND THE OTHER SECTIONS OF DIVISION 16000. 2. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTOR'S WITH ALL DIVISIONS OF WORK. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO PROVIDE THEIR SUBCONTRACTORS WITH A COMPLETE SET OF BID DOCUMENTS. 3. THIS CONTRACTOR IS RESPONSIBLE FOR SCHEDULING THE COMPLETION AND INSPECTION OF THEIR WORK AND THE WORK OF THEIR SUBCONTRACTORS WORK TO COMPLY WITH THE SCHEDULE AND THE PROJECT COMPLETION DATE. 4. THIS CONTRACTOR SHALL VISIT THE SITE PRIOR TO SUBMITTAL OF BID TO DETERMINE CONDITIONS AFFECTING THE WORK ANY ITEMS WHICH ARE NOT COVERED IN THE BID DOCUMENTS OR ANY PROPOSED SUBSTITUTIONS SHALL BE LISTED SEPARATELY AND QUALIFIED IN THE CONTRACTOR'S BID. SUBMITTAL OF BID SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF EXISTING CONDITIONS AND ANY MODIFICATIONS WHICH ARE REQUIRED TO MEET THE INTENT OF THE DRAWINGS AND SPECIFICATIONS. FAILURE TO VISIT THE SITE DOES NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY IN PERFORMANCE OF WORK. 5. REFER TO RESPONSIBILITY SCHEDULE ON THE ELECTRICAL DRAWINGS FOR INFORMATION IN REGARD TO RESPONSIBILITY OF WORK OR ITEMS WHICH MAY AFFECT BID. SECTION 16002 - GENERAL REQUIREMENTS A. THIS CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, SERVICES, TOOLS, TRANSPORTATION, INCIDENTALS AND DETAILS NECESSARY TO PROVIDE COMPLETE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS, CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD, OR TENANT SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR. CLOSELY COORDINATE THE ENTIRE INSTALLATION WITH LANDLORD, AND THE TENANT PROJECT MANAGER AS REQUIRED. B. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE PROVIDED EVEN THOUGH NOT SPECIFICALLY MENTIONED IN BOTH. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK OR WHICH IS USUALLY INCLUDED IN WORK OF SIMILAR CHARACTER, SHALL BE PROVIDED AS PART OF CONTRACT. C. WHERE THE DRAWINGS OR SPECIFICATIONS CALL FOR ITEMS WHICH EXCEED CODES OR THE LANDLORD'S TENANT CRITERIA, THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING AND INSTALLING THE SYSTEM WITH THE MORE STRINGENT REQUIREMENTS AS DESIGNED AND DESCRIBED ON THESE DRAWINGS, UNLESS SPECIFICALLY NOTED OTHERWISE. D. ALL ELECTRICAL WORK SHALL BE INSTALLED SO AS TO BE READILY ACCESSIBLE FOR OPERATING, SERVICING, MAINTAINING AND REPAIRING. THIS CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUFFICIENT SERVICE ACCESS TO ALL EQUIPMENT. E. ALL WORK SHALL BE PERFORMED IN A NEAT PROFESSIONAL MANNER USING GOOD ENGINEERING AND CONSTRUCTION PRACTICES. F. UNLESS SPECIFICALLY NOTED OTHERWISE, MATERIALS, PRODUCTS, AND EQUIPMENT, INCLUDING ALL COMPONENTS THEREOF, SHALL BE NEW, UNDERWRITERS LABORATORIES LISTED AND LABELED AND SIZED IN CONFORMITY WITH REQUIREMENTS OF THE NATIONAL ELECTRICAL CODE, STATE AND LOCAL CODES, WHICHEVER IS MORE STRINGENT. SECTION 16003 - CODES A. ALL WORK SHALL CONFORM TO THE LATEST ADOPTED EDITION OF THE NATIONAL ELECTRICAL CODE, LANDLORD'S CRITERIA, THE STATE'S, COUNTY'S, CITY'S AND LOCAL CODES AND ORDINANCES, SAFETY AND HEALTH CODES, NFPA CODES, ENERGY CODES, AND ALL OTHER APPLICABLE CODES AND REQUIREMENTS. THIS CONTRACTOR SHALL INQUIRE INTO AND COMPLY WITH ALL APPLICABLE CODES, ORDINANCES, AND REGULATIONS. THIS CONTRACTOR SHALL INCLUDE ANY CHANGES REQUIRED BY CODES IN THE BID AND IF THESE CHANGES ARE NOT INCLUDED IN THE BID, THEY MUST BE QUALIFIED AS A SEPARATE LINE ITEM IN THE BID. AFTER CONTRACT IS ISSUED, NO ADDITIONAL COST DUE TO CODE ISSUES SHALL BE REIMBURSED BY THE OWNER TO THE CONTRACTOR. SECTION 16004 - LICENSES, PERMITS, INSPECTIONS & FEES A. THIS CONTRACTOR SHALL OBTAIN AND PAY FOR ALL LICENSES, PERMITS, INSPECTIONS, AND FEES REQUIRED OR RELATED TO THEIR WORK. B. FURNISH TO THE TENANT'S PROJECT MANAGER ALL CERTIFICATES OF INSPECTION AND FINAL INSPECTION APPROVAL AT COMPLETION OF PROJECT. SECTION 16005 - TRADE NAMES, MANUFACTURERS AND SHOP DRAWINGS A. WHERE TRADE NAMES AND MANUFACTURERS ARE USED ON THE DRAWINGS OR IN THE SPECIFICATIONS, THE EXACT EQUIPMENT SHALL BE USED AS A MINIMUM FOR THE BASE BID. ADDITIONALLY, ONLY MANUFACTURERS CONSIDERED AS AN EQUAL OR BETTER IN ALL ASPECTS TO THAT SPECIFIED WILL BE REVIEWED. ALL SUBSTITUTIONS ARE SUBJECT TO APPROVAL IN WRITING, BY TENANT'S PROJECT MANAGER THROUGH PRIOR SHOP DRAWING SUBMITTAL PROCESS FOR ACCEPTANCE. THE USE OF ANY UNAUTHORIZED EQUIPMENT SHALL BE SUBJECT TO REMOVAL AND REPLACEMENT AT THE CONTRACTOR'S EXPENSE. B. ELECTRICAL CONTRACTOR SHALL SUBMIT ONLY SUBSTITUTION REQUESTS TO TENANT'S PROJECT MANAGER FOR APPROVAL. SUBMISSIONS SHALL BE MADE EARLY ENOUGH IN PROJECT TO ALLOW FOUR (4) WORKING DAYS FOR TENANT'S PROJECT MANAGER'S REVIEW WITHOUT CAUSING DELAYS OR CONFLICTS TO THE JOB'S PROGRESS SUBMITTALS SHALL BEAR THE STAMP OF THE GENERAL CONTRACTOR AND THE SUB -CONTRACTOR SHOWING THAT THEY HAVE REVIEWED AND CONFIRMED THAT THE SUBMITTALS ARE IN CONFORMANCE WITH THE CONTRACT DRAWINGS AND SPECIFICATIONS OR INDICATE WHERE EXCEPTIONS HAVE BEEN TAKEN. SECTION 16006 - GUARANTEE A. THIS CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORK PROVIDED UNDER THEIR CONTRACT AND SHALL MAKE GOOD, REPAIR OR REPLACE AT THEIR OWN EXPENSE, ANY DEFECTIVE WORK, MATERIAL, OR EQUIPMENT WHICH MAY BE DISCOVERED WITHIN A PERIOD OF 12 MONTHS FROM THE DATE OF ACCEPTANCE (IN WRITING) OF THE INSTALLATION BY THE TENANT'S PROJECT MANAGER. EXTENDED WARRANTIES ARE SPECIFIED WITH INDIVIDUAL EQUIPMENT. B. TENANT SHALL PROVIDE A COMPLETE 12 -MONTH WARRANTY FOR ALL PARTS ON EQUIPMENT PROVIDED BY TENANT AND TENANT'S VENDORS. THIS CONTRACTOR SHALL NOT BEAR ADDITIONAL WARRANTIES BEYOND A COMPLETE WORKING SYSTEM, AND AS SUCH, NO ADDITIONAL MONIES SHOULD BE INCLUDED IN THE BID. SECTION 16007 - RECORD DRAWINGS A. THIS CONTRACTOR SHALL MAINTAIN ONE COPY OF DRAWINGS ON THE JOB SITE TO RECORD DEVIATIONS FROM CONTRACT DRAWINGS, SUCH AS: 1. LOCATION OF CONCEALED CONDUIT AND WIRING. 2. LOCATION OF JUNCTION BOXES. 3. REVISIONS, ADDENDUMS, AND CHANGE ORDERS. 4. SIGNIFICANT DEVIATIONS MADE NECESSARY BY FIELD CONDITIONS, APPROVED EQUIPMENT SUBSTITUTIONS, AND CONTRACTOR'S COORDINATION WITH OTHER TRADES. B. AT COMPLETION OF PROJECT AND BEFORE FINAL APPROVAL, THE CONTRACTOR SHALL MAKE ANY FINAL CORRECTIONS TO DRAWINGS AND CERTIFY THE ACCURACY OF EACH PRINT BY SIGNATURE THEREON. ONE COPY OF THE MOST RECENT SET OF DRAWINGS WITH TEMPERATURE CONTROL DRAWINGS INCLUDED SHALL BE DELIVERED TO TENANT'S PROJECT MANAGER. SECTION 16008 - DISCREPANCIES IN DOCUMENTS A. DRAWINGS (PLANS, SPECIFICATIONS, AND DETAILS) ARE DIAGRAMMATIC AND INDICATE THE GENERAL LOCATION AND INTENT OF THE ELECTRICAL SYSTEMS. WHERE DRAWINGS, EXISTING SITE CONDITIONS, SPECIFICATIONS OR OTHER TRADES CONFLICT OR ARE UNCLEAR, ADVISE TENANT'S PROJECT MANAGER, IN WRITING OF VARIATIONS TO CONTRACT DOCUMENTS PRIOR TO SUBMITTAL OF BID. OTHERWISE, TENANT'S PROJECT MANAGER'S INTERPRETATION OF CONTRACT DOCUMENTS OR CONDITIONS SHALL BE FINAL WITH NO ADDITIONAL COMPENSATION PERMITTED. SECTION 16009 - DEMOLITION A. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR THE COORDINATION OF THE DEMOLITION OF EXISTING WORK AND THE DEMOLITION PROVIDED BY THE GENERAL CONTRACTOR COORDINATE WITH THE GENERAL CONTRACTOR ANY EXISTING EQUIPMENT REQUIRED TO BE LEFT INTACT. B. THIS CONTRACTOR SHALL VERIFY SCOPE OF WORK WITH THE GENERAL CONTRACTOR FOR THE REMOVAL OF ALL EXISTING LIGHT FIXTURES, RECEPTACLES, SWITCHES, ETC. NOT BEING REUSED ON THIS PROJECT UNLESS SPECIFICALLY NOTED OTHERWISE. CONTRACTOR MUST VERIFY WITH THE LANDLORD ALL PRESUMED ABANDONED EQUIPMENT PRIOR TO REMOVAL. ALL EXTRANEOUS ITEMS IN THE SPACE OR ON THE ROOF NOT APPLICABLE TO THE NEW WORK MUST BE REMOVED AND ROOF/WALL/FLOOR PATCHED/REPAIRED TO MATCH EXISTING STRUCTURE. EXISTING ABANDONED CONDUIT OR EQUIPMENT IN THE FLOOR, EMBEDDED IN CONCRETE, OR OTHERWISE INACCESSIBLE, ARE TO BE CUT OFF AND SEALED BELOW OR WITHIN FLOOR OR WALL LEVEL WHEN THEY ARE NOT TO BE REUSED IN THIS PROJECT. IF REQUIRED BY LANDLORD OR CODES, ABANDONED CONDUIT MUST BE REMOVED TO POINT OF ORIGIN. CONFIRM EXTENT OF DEMOLITION WITH THE GENERAL CONTRACTOR PRIOR TO BID PROPOSAL AS DIRECTED BY THE GENERAL CONTRACTOR AND TENANT. ALL UNUSED x EXISTING PLENUM RATED CABLING IS TO BE REMOVED COMPLETELY. SECTION 16010 - CUTTING AND PATCHING #: A. THE CONTRACTOR SHALL PERFORM ALL CUTTING AND PATCHING AS REQUIRED FOR THE INSTALLATION OF THE WORK UNDER THIS SPECIFICATION. NO CUTTING OF THE STRUCTURE SHALL BE PERMITTED WITHOUT WRITTEN APPROVAL OF THE LANDLORD AND ARCHITECT OR ENGINEER. B. PATCHING SHALL BE OF THE SAME WORKMANSHIP, MATERIAL AND FURNISH AND SHALL MATCH ACCURATELY ALL SURROUNDING CONSTRUCTION IN A MANNER SATISFACTORY TO THE ARCHITECT AND TENANT'S PROJECT MANAGER. C. EXISTING UTILITIES, ETC. THAT ARE DAMAGED DURING THE CONSTRUCTION PERIOD, WHETHER OR E NOT DUE TO THE CONTRACTOR'S NEGLIGENCE SHALL BE REPAIRED OR REPLACED BY THE CONTRACTOR AND LEFT IN A CONDITION SUITABLE TO THE LANDLORD AND TENANT'S PROJECT MANAGER. '. SECTION 16011 -SLEEVES A. THIS CONTRACTOR SHALL PROVIDE SLEEVES TO PROTECT EQUIPMENT OR FACILITIES IN THE INSTALLATION. EACH SLEEVE SHALL EXTEND THROUGH IT'S RESPECTIVE FLOOR, WALL OR PARTITION AND SHALL BE CUT FLUSH WITH EACH SURFACE EXCEPT SLEEVES THAT PENETRATE THE FLOOR, WHICH SHALL EXTEND 2" ABOVE THE FLOOR. CONTRACTOR MUST COORDINATE THROUGH THE LANDLORD ANY CORE DRILLING OR CUTTING OF OPENINGS IN MASONRY FLOORS OR WALLS. B. ALL SLEEVES AND OPENINGS THROUGH FIRE RATED WALLS AND/OR FLOORS SHALL BE FIRE SEALED WITH CALCIUM SILICATE, SILICONE "RTV" FOAM, "3M" FIRE RATED SEALANTS OR EQUAL, SO AS TO RETAIN THEIR FIRE RATING. C. SLEEVES IN BEARING AND MASONRY WALLS, FLOORS AND PARTITIONS SHALL BE STANDARD WEIGHT STEEL PIPE FINISHED WITH SMOOTH EDGES. FOR OTHER THAN MASONRY PARTITIONS, THROUGH SUSPENDED CEILINGS, OR FOR CONCEALED VERTICAL CONDUIT, SLEEVES SHALL BE NO 22 U.S.G GALVANIZED STEEL MINIMUM. SECTION 16012 - HANGERS A. HANGERS SHALL INCLUDE ALL MISCELLANEOUS STEEL SUCH AS ANGLE IRON, WIRE, UNISTRUT, C -CLAMPS WITH RETAINING CLIPS, CHANNELS, HANGER RODS, ETC., NECESSARY FOR THE INSTALLATION OF WORK. F B. HANGERS SHALL BE FASTENED TO BUILDING STEEL, CONCRETE, OR MASONRY, BUT NOT TO PIPING. HANGING FROM METAL DECK IS NOT PERMITTED. HANGERS MUST BE ATTACHED TO UPPER CHORD OF BAR JOIST. WHERE INTERFERENCES OCCUR, IN ORDER TO SUPPORT CONDUIT OR BOXES, THE CONTRACTOR MUST INSTALL TRAPEZE TYPE HANGERS OR SUPPORTS WHICH SHALL BE LOCATED I WHERE THEY DO NOT INTERFERE WITH ACCESS TO FIRE DAMPERS, VALVES, JUNCTION BOXES, ACCESS DOORS, OTHER EQUIPMENT SERVICE REQUIREMENTS AND/OR OTHER TRADES. HANGER TYPES AND INSTALLATION METHODS ARE SUBJECT TO LANDLORD CRITERIA. DIVISION 16200 - ELECTRICAL SECTION 16201 - SUMMARY OF WORK A. THIS CONTRACTOR SHALL FURNISH ALL LABOR, MATERIALS, EQUIPMENT NECESSARY FOR REASONABLY IMPLIED AND INCIDENTAL TO, THE FURNISHING, INSTALLATION, COMPLETION AND TESTING OF ALL THE WORK FOR THE ELECTRICAL SYSTEMS AS CALLED FOR IN THE SPECIFICATIONS, AND AS REQUIRED BY JOB CONDITIONS, TO INCLUDE, BUT NOT BE LIMITED TO THE FOLLOWING: 1. WORK IN THE LANDLORD'S MAIN DISTRIBUTION EQUIPMENT ROOM SHALL BE AS INDICATED, AND/OR REQUIRED BY EXTENDING SERVICE TO THE LEASED SPACE. 2. COMPLETE POWER AND LIGHTING DISTRIBUTION SYSTEMS INCLUDING ALL PANELS AND COMPLETE BRANCH CIRCUIT WIRING SYSTEM. 3. COMPLETE LIGHTING FIXTURE INSTALLATION. 4. COMPLETE TELEPHONE CONDUIT SYSTEM, INCLUDING SERVICE CONDUIT FROM POINT OF CONNECTION TO LANDLORDS SYSTEM AND ALL TERMINAL DEVICES, BOXES, CONDUIT, PLATES, ETC. 5. TEMPORARY ELECTRICAL SERVICE AS REQUIRED FOR CONSTRUCTION. 6. WIRING AND FINAL CONNECTION TO ALL SIGNS AND GRAPHICS, FURNISHED BY THE OWNER. 7. PROVISIONS FOR FIRE ALARM/SMOKE EVACUATION SYSTEM AND EXTENSION OF LANDLORD SYSTEM (IF APPLICABLE). 8. TESTING OF ALL CABLES AND CIRCUIT WIRING AFTER INSTALLATION. k 9. TESTING OF ALL ELECTRICAL EQUIPMENT. 10. WARRANTY OF ALL WORK FOR A PERIOD OF ONE YEAR FROM DATE OF PROJECT CLOSE-OUT. B. PROVIDE ELECTRICAL SERVICE AS INDICATED ON THE DRAWING. ALL WORK NOT SPECIFICALLY NOTED AS BEING BY THE LANDLORD OR THE POWER COMPANY SHALL BE PROVIDED BY THE ELECTRICAL CONTRACTOR CLOSELY COORDINATE ENTIRE INSTALLATION WITH THE LANDLORD AND THE POWER COMPANY. CONTRACTOR SHALL MAKE ARRANGEMENT WITH THE POWER COMPANY FOR INSTALLATION OF METERING AS REQUIRED BY THE LANDLORD. C. CONTRACTOR SHALL MAKE ARRANGEMENTS WITH THE LOCAL TELEPHONE UTILITY FOR TELEPHONE SERVICE ; TO THE SPACE, CONDUIT SYSTEM FOR TELEPHONE DISTRIBUTION TO THE LEASED PREMISES SHALL BE PROVIDED WHERE REQUIRED FOR UTILITY COMPANY WIRES. COORDINATE INSTALLATION OF TELEPHONE t WORK AND INSTALL ALL CONDUIT (IF REQUIRED BY LANDLORD OR LOCAL CODE) FOR TELEPHONE SYSTEM WITHIN THE LEASED SPACE. OUTLET BOXES SHALL BE 4" SQUARE MINIMUM WITH SINGLE DEVICE COVER AND TELEPHONE PLATE. D. FURNISH ALL LABOR, MATERIALS, EQUIPMENT AND TOOLS TO PERFORM ELECTRICAL WORK SHOWN, NOTED OR SCHEDULED FOR A COMPLETE AND FINISHED INSTALLATION. SECTION 16202 - MATERIALS 1 A. MATERIALS PRODUCTS AND EQUIPMENT, INCLUDING COMPONENTS THEREOF, SHALL BE NEW AND SUCH AS APPEARS ON THE UNDERWRITER'S LABORATORY LIST OF APPROVED ITEMS AND SHALL MEET THE REQUIREMENTS OF RECOGNIZED STANDARDS. B. CONDUIT SHALL BE STANDARD STEEL, IC OR EMT (THIN WALL) ACCORDING TO CODE REQUIREMENTS. CONDUIT SHALL BE CONCEALED IN FINISHED AREAS EXCEPT AS OTHERWISE APPROVED BY TENANT'S 1 PROJECT MANAGER. EMT CONNECTIONS SHALL BE COMPRESSION TYPE. MINIMUM SIZES OF CONDUIT SHALL BE 3/4", EXCEPT 1/2" FOR SWITCH LEGS. EMT SHALL BE GALVANIZED OR ELECTRO -GALVANISED. EMT SHALL BE USED FOR FEEDERS AND BRANCH CIRCUITS RUN ABOVE THE SUSPENDED CEILING OR CONCEALED IN INTERIOR PARTITIONS. EMT SHALL NOT BE CONCEALED IN POURED CONCRETE FLOOR OR WALLS. USE IMC FOR UNDER SLAB INSTALLATIONS. IMG IS PERMITTED WITH SCREW CONNECTIONS. FLEXIBLE METALLIC TUBING MAY BE USED IN LIEU OF EMT FOR CONCEALED BRANCH CIRCUIT WIRING ONLY, WHERE PERMITTED BY LOCAL AUTHORITIES. FLEXIBLE METAL CONDUIT MAY BE USED ONLY FOR SHORT CONNECTIONS TO FIXTURES AND EQUIPMENT PERMITTED BY CODE. C. ALL CONDUCTORS SHALL BE SOFT DRAWN, ANNEALED COPPER, WITH 600 VOLT INSULATION. 1. #10 AND SMALLER -SOLID, #8 AND LARGER -STRANDED. MINIMUM WIRE SHALL BE #12, EXCEPT #14 MAYBE ,, USED FOR CONTROL APPLICATIONS. 2. ALL WIRE AND CABLE SHALL BE NEW AND SHALL BE BROUGHT TO THE SITE IN UN BROKEN PACKAGES. 3. GENERAL WIRING SHALL HAVE THHN INSULATION. I 4. ALUMINUM CONDUCTORS, ROMEX OR BX ARE NOT PERMITTED. 5. WIRE CONNECTORS SHALL BE EQUAL TO SCOTCH - LOCK FOR #8 AND SMALLER, AND T &BLOCK TIE FOR #6 AND LARGER. 6. WIRES SHALL BE COLOR CODED IN KEEPING WITH LANDLORD'S CONVENTION. D. OUTLET BOXES AND COVERS SHALL BE ONE PIECE, GALVANIZED OR SHERARDIZED STEEL, 4" x 4" KNOCK - OUT TYPE WITH FIXTURE STUDS AS REQUIRED. JUNCTION BOXES, PULL BOXES AND COVERS SHALL BE GALVANIZED STEEL, CODE GAUGE AND SIZE. E. WIRING DEVICES: 1. DEVICES AND COVER PLATES SHALL BE SPECIFICATION GRADE WITH A MINIMUM RATING OF 20 AMPS. COLOR OF DEVICES AND COVER PLATES IN SALES AREA GYP BOARD, TOILET ROOM AND STOCK ROOM "f0 BE WHITE. }; IN SALES AREA WAINSCOT AND MILLWORK THEY ARE TO BE IVORY. DEVICES AND COVERPLATES TO BE MANUFACTURED BY HUBBELL. EQUALS BY LEVITON OR COOPER WIRING DEVICES / EAGLE ELECTRIC. DUPLEX RECEPTACLE : HUBBELL #5262. QUADRAPLEX RECEPTACLE: HUBBELL #5262 UNDER ONE (TWO GANG -TYPE) COVER PLATE. ISOLATED GROUND RECEPTACLE : HUBBELL #IG -5262. QUADRAPLEX ISOLATED GROUND RECEPTACLE: (2)HUBBEL MG -5262 UNDER ONE (TWO GANG TYPE) COVER PLATE. WEATHER PROOF RECEPTACLE: HUBBELL #GF -5262-1 WITH "WP26" ALUMINUM COVER PLATE. SPST SWITCH: HUBBELL #HBL-1221. THREE WAY SWITCH: HUBBELL #HBL-1223. % F. THIS CONTRACTOR SHALL PROVIDE, INSTALL AND CONNECT A COMPLETE SYSTEM OF GROUNDING FOR ALL EQUIPMENT AND STRUCTURES. A GOOD MECHANICAL AND ELECTRICAL CONNECTION SHALL BE MADE WITH APPROVED GROUNDING CONNECTIONS, ELECTRICAL SYSTEM AND EQUIPMENT GROUNDS SHALL COMPLY WITH ALL LOCAL, STATE AND N.E.C. CODES AND REGULATIONS. PANELS, CONDUIT SYSTEMS, MOTOR FRAMES, LIGHTING FIXTURES AND OTHER EQUIPMENT THAT ARE PART OF THIS INSTALLATION SHALL BE SECURELY GROUNDED BOTH MECHANICALLY AND ELECTRICALLY IN ACCORDANCE WITH ALL CODES. MAIN GROUNDING SYSTEM SHALL BE SIZED TO CONFORM WITH SECTION 250 OF THE NATIONAL ELECTRIC CODE. PROVIDE CONDUIT 'TO PROTECT GROUND WIRE FROM DAMAGE TO A HEIGHT OF 6 FEET ABOVE FLOOR. MAKE ALL JOINTS AND CONNECTIONS OF THE CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL AND ELECTRICAL GROUND THROUGH ENTIRE SYSTEM. GROUND ALL THREE WIRE RECEPTACLES TO THE OUTLET BOXES. GROUND NEUTRAL FROM THE TRANSFORMER CONNECTED TO BUILDING STEEL. GROUND CONDUCTOR SHALL BE SUPPLIED IN ALL NON-METALLIC CONDUIT. A SEPARATE ISOLATED, INSULATED E GROUND SYSTEM SHALL BE INSTALLED FOR ELECTRONIC CASH REGISTER. G. ALL PASTEBOARDS SHALL BE STANDARD DEAD -FRONT CONSTRUCTION WITH SIZE AND NUMBER OF SINGLE AND MULTI -POLE BOLT -ON BRANCH BREAKERS AS INDICATED ON THE PANEL SCHEDULE, AND WITH MAIN BREAKER AND MAIN LUGS AS INDICATED ON THE DRAWINGS, PANEL BUSSING SHALL BE COPPER. PANEL BOARDS SHALL BE COMPLETE WITH TRIM, DOOR, CONCEALED HINGES, FLUSH LOCK, DIRECTORY FRAME AND NEATLY TYPED CO PLETED DIRECTORY CARDS. ALL PANEL BOARDS SHALL HAVE DISTRIBUTED BUSSING AND SEQUENCE NUMBERING WITH NO TWO CONSECUTIVE CIRCUIT NUMBERS TIED TO THE SAME BUS OR PHASE. ALL PANELS AND BREAKERS ARE PRE -PURCHASED AND SHALL BE GET AS PART TENANT'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. ALL CIRCUIT BREAKERS USED FOR CONTROL OF LIGHTING CIRCUITS SHALL BE "SWD" RATED. H. DRY TYPE STEP - DOWN TRANSFORMER SHALL HAVE NEMA CLASS F INSULATION ON UNITS BELOW 30 KVA AND NEMA CLASS H INSULATION ON UNITS 30 KVA AND ABOVE. TRANSFORMER TO BE GENERAL PURPOSE VENTILATED TYPE WITH ALUMINUM WINDINGS. TRANSFORMER IS PRE PURCHASED AND SHALL BE GE AS PART TENANT'S NATIONAL ACCOUNT RELATIONSHIP AND SHIPPED TO THE JOB SITE FOR INSTALLATION BY THE ELECTRICAL CONTRACTOR. I. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, 600 VOLT RATED, QUICK-MAKE/QUICK-BREAK, WEATHER PROOF (WHERE APPLICABLE), FUSED/NON FUSED AS SHOWN ON THE DRAWINGS. SWITCHES USED FOR SERVICE ENTRANCE SHALL BE "SE" RATED. STARTERS SHALL BE MINIMUM NEMA SIZE 1. DISCONNECT SWITCHES AND COMBINATION STARTER DISCONNECT SWITCHES ARE PURCHASED AND INSTALLED BY THE ELECTRICAL CONTRACTOR AND SHALL BE GE. J. ELECTRICAL CONTRACTOR SHALL PROVIDE ELECTRIC SERVICE AND MAKE CONNECTIONS TO THE HVAC EQUIPMENT, SIGNS AND GRILLE MOTORS (IF APPLICABLE) AS SHOWN ON THE DRAWINGS. K. THE ISOLATED CIRCUIT OUTLETS AT CASH WRAP AREAS SHALL BE CLEARLY AND COMPLETELY MARKED FOR UNMISTAKABLE IDENTIFICATION BY THE OWNER'S EMPLOYEES. L. TEMPORARY WIRING SHALL BE REMOVED WHEN WORK IS COMPLETED. M. NO CONDUIT SHALL BE RUN THROUGH HVAC DUCTS. N. FINALLY 1. IT IS THE INTENT THAT THE FOREGOING WORK SHALL BE COMPLETED IN EVERY RESPECT AND THAT ANY MATERIAL OR WORK NOT SPECIFICALLY MENTIONED OR SHOWN ON THE DRAWINGS BUT NECESSARY TO FULLY COMPLETE THE WORK SHALL BE FURNISHED. THE LOCATION OF RECEPTACLES AND FIXTURES SHOWN ON THE DRAWING ARE APPROXIMATE AND THE OWNER SHALL HAVE THE RIGHT TO RELOCATE ANY RECEPTACLE OR FIXTURES BEFORE THEY ARE INSTALLED WITHOUT ANY ADDITIONAL COST. IWPARTNERS brand: operations: build 7007 DISCOVERY BLVD DUBLIN, OR 43017 614.634.7000 T W DPARTNERS.COM SEMINOLE T.C. 200 TOWNE CENTER CIRCLE SPACE #1311 C SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 �®iwo9et�B®® J (D'; STATE OF .' Qom. 'RI -fee I 7010 )joy 20 7-013 ISSUE DATES PRELIM SET: 10-16-2013 FINAL SET: 11-6-2013 PERMIT SET: 11-20-2013 REVISIONS ID DRAWING NUMBER DOOR SCHEDULE Description I DESCRIPTION Double Glass Cabinet measuring 2'x6' with an overall height of 100".Lower section has DBL GS VALSPAR DOOR HARDWARE MARK LOCATION SIZE TYPE CA - back FRAME DOOR DESCRIPTION HARDWARE FIRE RATING A. HARDWARE AS PROVIDED BY ROLLING GRILLE SERVICE ENTRANCE/ ROLL-UPO 8'-U" X 8 U' IS STEEL ALUM. OVERHEAD DOOR SERIES 670 MANUAL DL N/A 42"R GRILLE SQ A Z_ Wood shelves, measuring 12"d, available in 4',6',8' lengths WS PUSH-UP DOOR OR APPROVED EQUAL A Wood shelving is hung in doubles, the lower one at 66"h and upper at 79"h MANUFACTURER WITH U -CHANGE LOCK CYLINDER WITH 4' Wood shelf elevation, shelves are hung at 24",40",56",72" Two-tiered 4' wood shelves, upper shelf is hung at 76"h, bottom bench is at 18"h note: 3FO * There needs to be 3" gaps on either side to allow for the hangers to hang freely on the BEHR CLR: SEASIDE SAND face -out brackets THUMBTURN ON STORE SIDE. GC TO PROVIDE AND INSTALL SIGNAGE ON STORE SIDE OF BOTTOM RAIL OF Stacked shelving for stockroom, 12" deep wall mounted. Shelf with pole @5'3 & Top shelf SS OLYMPIC at 7' aff, variable lengths NEW DESIGN STANDARD - JELDWEN 15 PT -5 CLR: HEIRLOOM LACE OB STOCK ROOM T-0" X 6'-8" X 1 3/8" B Small microwave & fridge for stockroom 5/A1D 1 WD PANEL LITE DOOR. PAINT PT -4. g N/A GRILLE STATING "GRILLE TO REMAIN IN FULL OPEN CLR: BROWN Three-piece unit composed of right/left/center, with wood or glass shelves, lights Armoire Side units measure 16"d x 35"w x 100"h Center unit measures 20"d x 36"w x 100"h TEMPERED GLAZING TO BE FROSTED. ADA Bench Measuring 42"wx18"hx20"w POSITION DURING STORE HOURS WHEN OCCUPIED BY THE GENERAL PUBLIC." 6" WOOD BASE SALES (SUPPLIED RESTROM BY FRANCESCA'S) C RESTROOM 3'-0" X 6'-8" X 1 3/8" C 0 5/AD 1 WD DOOR, PA NT PT -2 C N/A CLR: WHITE / MULTI - PATTERN BY OWNER w 0 GROUT: POLYBLEND / CUSTOM B. DECORATIVE PRIVACY LOCKSET - G.C. SHALL NOT CLR: #333 ALABASTER 12"x12" VINYL FLOORING STOCK ROOM/ pC VCT 1 CLR: BEIGE RESTROOM INSTALL CLOSER. 0 KARNDEAN SALES � VP 1 VINYL PLANK - HCO3 C. PRIVACY LOCKSET - G.C. SHALL NOT INSTALL CLOSER. CLR: DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ CLG-1 NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ d TEGULAR EDGE CLR: WHITE RESTROOM J U CLEAR OFENINCa WIDTH STOREFRONT TEtd510N —� NEW GYP. BD. CEILING ------- DRIVE END -- END PT -4 PT -2 r r PT -2 FROSTED TEMPERED GLAZING U IFTI NOTE: DOOR HARDWARE SHALL BE EASY TO GRASP AND SHALL g NOT REQUIRE GRASPING, TIGHT PINCHING, OR TWISTING OF WRIST. ALL DOORS SHALL HAVE LEVER HARDWARE, RELEASES,OR PUSH-PULL PLATES CENTERED APANIC B (, BETWEEN 30-44" A.FF. ALL LOCKING DEVICES MUST MEET ANSI AND TAS STANDARDS. 5/8" GYP. BD. DBL. 3 5/8" METAL / TRIM DOOR JAN FRT WOOD BLOCKING 5 DOOR HEAD & JAMB DETAIL 311 =1-0 11 WALL LEGEND 5/8" TYPE "X" GYP BD. TO 6" ABOVE CEILING - OMIT GYP. BD. ON ONE SIDE AT FURRED WALLS, A MOISTURE RE SISTANT GYP ON RESTROOM WALLS 3 5/8" X 20 GA. METAL STUDS @ 16" O.C. TO DECK SEE SECTION 4/A1.1 FRAME 5/8" GYP. BD. DBL. 3 5/8" METAL STUDS. 20 GA. TYP. TRIM FRT WOOD BLOCKING DOORJAMB FRAME EXISTING 5/8" TYPE "X" GYP.BD. - G.C. TO PATCH & REPAIR AS REQUIRED. C MAINTAIN ALL EXISTING FIRE RATINGS. INSTALL ON TENANT SIDE IF NOT EXISTING (E) 6" METAL 5/8" STUD NEW WALLS DEMISING WALLS NEW WALLS USE 20GA. MTL STUDS UNLESS OTHERWISE NOTED CW RESTROOM 5/8" TYPE "X" GYP BD. TO 6" ABOVE CEILING, - OMIT GYP. BD ON ONE SIDE AT FURRED WALLS, MOISTURE RESISTANT GYP ON RESTROOM WALLS 3 5/8" X 20 GA. METAL STUDS @ 16" O.C. TO 8'-6" 5/8" SEE SECTION 3/A1.1 J -MOLD ON TOP OF GYP. BD. 3 5/8x20 GA DIAGONAL DEEP LEG (18 GA MIN) CONT. EL BRACING AT 48" O.C. SLOTTED DEFLECTION TRACK `t ATTACH TO TOP OF (CLARK-DIETRICH SLP -TRK) W/ cJ WALL WITH SIMPSON L30 ATTACHMENT TO STEEL U +8'-6" A.F.F. rik LU CLIPS. ATTACH BRACING JOISTS FRAMING ABOVE PER TO FRAMING ABOVE PER T.O. WALL DETAILS ON A3.1. DO NOT DETAILS ON A3.1. ATTACH TO METAL DECK. +8'-0" A.F.F. OB U P TO DECK AC f CEILING PER SCHEDULE 20 GAUGE CONT. 3 5/8", 20 GA MTL. STUDS & TRACK TO MATCH GYP. BD. WALL SYSTEM. WALL STUD WIDTH Ap (2) 0.145" DIA HILTI X -DNI WALL BASE, SEE UNIVERSAL PAF @ 16" OC FINISH 3CHEDULEif (1-1/4" EMBED). (2) 0.145" DIA HILTI X -DNI (1) #10-16 SCREW PER STUD BASE, WHERE OCCURS. SEE UNIVERSAL PAF @ 16" OC FINISH SCHEDULE (1-1/4" EMBED). FLANGE, TYP. NEW CONCRETE +0'-0" SLAB BY G.C. FINISH FLOOR A TO SLAB WALL ATTACHMENT DETAIL 3 RESTROOM WALL DETAIL 3'= 1, 0, 1 112" = 11-011 60" CLR IS" 24" MIN 36" CWAB BAR - -� I G.C. To INSTALL BLOCKIN[s IN WALL I F 0� I o = 5/A4 ` LIN- r 48" CLR - 7/A4 1 42" CsRAB BAR - IG.C. To INSTALL }' BLOCKING IN WALL. I B„jk; Frrs �'a SEE SHEET A4 1„\ C y' FOR �STROOM ELEVATIONS 1 .....<> ENLARGED RESTROOM PLAN Francesca's FIXTURE SCHEDULE �CONSTR.GEN.NOTES CONSTRUCTION KEYNOTES 1. DIMENSIONS ARE TO FINISH SURFACES UNLESS NOTED OTHERWISE. 2. THE G.C. IS RESPONSIBLE FOR CONFIRMING OVERALL DIMENSIONS AND STRUCTURAL CONDITIONS PRIOR TO BEGINNING WORK. ANY DISCREPANCIES OR PROBLEMATIC CONDITIONS SHALL BE BROUGHT TO THE IMMEDIATE ATTENTION OF THE G.C.. 3. REPORT ALL SHELL BUILDING DEFECTS TO THE G.C. IMMEDIATELY UPON DISCOVERY. T.G.C. IS TO OBTAIN APPROVAL AND REQUIREMENTS FROM ON SITE TENANT COORDINATOR PRIOR TO ANY CUTTING OR DRILLING OF EXISTING FLOOR. TENANT IS RESPONSIBLE TO FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS IN THE SPACE. FAILURE TO PROPERLY FIELD VERIFY EXISTING CONDITIONS DOES NOT RELIEVE THE TENANT OF ANY EXPENSES OR RESPONSIBILITIES RESULTING FROM THAT FAILURE. NOTHING IS PERMITTED TO BE ATTACHED TO, BE SUSPENDED FROM, OR PENETRATE THE ROOF DECK. TENANTS MAY ATTACH TO JOIST(S), AT PANEL POINTS, OR TO THE STRUCTURAL STEEL. ALL WALL CONSTRUCTION SHALL BE SUPPORTED IN THIS MANNER. NO WELDING TOR SHOOTING INTO THE STRUCTURE IS PERMITTED. STRUCTURAL REINFORCING DETAILS MUST BE PROVIDED BY A REGISTERED STRUCTURAL ENGINEER TO TENANT COORDINATION FOR EQUIPMENT SUPPORT OR SUSPENSION, SERVICE PLATFORMS, DECK PENETRATIONS, ETC. - FOR LANDLORD'S RECORDS. ANY LANDLORD EQUIPMENT OR COMPONENT THAT IS EXISTING IN THE SPACE MUST REMAIN VISIBLE AND ACCESSIBLE TO THE LANDLORD. -I-ENANI” "I"O INS-fALL ACCESS PANELS AS NECESSARY, AND PROPERLY LABEL IN SPACE, COORDINATE PLACEMENT WITH MALL OPERATIONS DIRECTOR. TENANT'S STOCKROOM MAY NOT BE VISIBLE FROM THE SALES AREA. DOOR(S) LEADING TO THE STOCKROOM MUST HAVE AN AUTOMATIC CLOSURE. ALL CONCRETE PATCHING MUST BE LEVEL WITH THE EXISTING CONCRETE FLOOR. ALL FLOORING TRANSITIONS MUST BE SMOOTH & FLUSH. THE USE OF PLASTIC, VINYL, OR RUBBER TRANSITION STRIPS IS STRICTLY PROHIBITED. TENANTS MUST UTILIZE A HARD SURFACE TRANSITION. NO RUBBER OR VINYL BASE IS PERMITTED IN THE SALES AREA OF THE PREMISES. Item Description I DESCRIPTION Double Glass Cabinet measuring 2'x6' with an overall height of 100".Lower section has DBL GS VALSPAR sliding wood doors with inner shelf. Upper section consists of glass shelves, with lights Front Cashwrap meets ADA requirements with a center drop-down section measuring 36" CA -front wide at a height of 33" aff. Overall dimensions are 96"1 x 36" d x overall height of 44". CA - back Back Cashwrap; 8' long version, 2'4"d x 44"h. CA -back (18") OPTIONAL Back Cashwrap; 6' long, 18"d x 44"h Standard wood tables measure 2'9"x5'3", with an overall height of 2'6" T SERVICE ENTRANCE/ Optional tables measure 3'3"x5'6", which are noted as 3x5 IS Rectangle island, measure 72"w x 30"d x 42"h. U 36" round unfinished tables, 2'6"h DL 36" round wood tables with drop leaf, 2'6"h 42"R 42" round wood tiered table SQ Square island, measure 25 1/2"w x 25 1/2"d x 36 1/2"h Z_ Wood shelves, measuring 12"d, available in 4',6',8' lengths WS SALES AREA CEILING Q Wood shelving is hung in doubles, the lower one at 66"h and upper at 79"h 4WS 4' Wood shelf elevation, shelves are hung at 24",40",56",72" Two-tiered 4' wood shelves, upper shelf is hung at 76"h, bottom bench is at 18"h note: 3FO * There needs to be 3" gaps on either side to allow for the hangers to hang freely on the BEHR CLR: SEASIDE SAND face -out brackets * Do not attach the lower bench to the wall Stacked shelving for stockroom, 12" deep wall mounted. Shelf with pole @5'3 & Top shelf SS OLYMPIC at 7' aff, variable lengths Stk. Shelv. PT -5 CLR: HEIRLOOM LACE (4) 12" deep wall mounted shelving for stock room spaced equally with top shelf at 7' aff Shelf (1) 24" wide shelf mounted at 60" a.f.f. for loss prevention equipment M/F Small microwave & fridge for stockroom File Small file for stockroom Display Custom built displays for storefront, standard height is 24"aff, 36"d, variable length, finished with trim CLR: BROWN Three-piece unit composed of right/left/center, with wood or glass shelves, lights Armoire Side units measure 16"d x 35"w x 100"h Center unit measures 20"d x 36"w x 100"h Wood Bench for ADA Dressing room, attached to wall, with front legs. ADA Bench Measuring 42"wx18"hx20"w NOTE: PROVIDE CONCEALED F.R.T. WOOD BLOCKING AT ALL RETAIL FIXTURES ANCHORED TO WALLS. H �1 LEASE LINE. �2 EXISTING DEMISING WALL. G.C. TO PATCH & REPAIR AS REQUIRED. O ALL FIXTURES PROVIDED BY MILLWORK VENDOR. ® ALL WALLS ARE COVERED FROM FLOOR TO CEILING WITH PAINT. ALL WALLS TO BE BROUGHT TO A LEVEL 3 FINISH BEFORE PAINTING. OPREP CONCRETE SLAB FOR INSTALLATION OF NEW FLOOR FINISH PER MANUFACTURERS RECOMMENDATION. ALL FLOORING TRANSITIONS TO BE LEVEL AND FLUSH AND COMPLY WITH ANSI A117.1 & CALIFORNIA BUILDING CODE. 6� NEW ELECTRICAL PANEL. G.C. TO PULL SERVICE TO SPACE FROM LANDLORDS DESIGNATED LOCATION. SEE ELEC. 7O NEW INTERIOR WALLS. SEE WALL TYPE SCHEDULE FOR DETAILS. 8O NEW STOREFRONT SYSTEM. SEE ELEVATIONS FOR MORE INFO. 9� NEW ADA RESTROOM. SEE DETAIL THIS SHEET AND ELEVATIONS ON A4 FOR MORE INFORMATION. SEE PLUMBING FOR FIXTURE SPECS. 10 APPROXIMATE LOCATION OF FIRE EXTINGUISHER. GC TO COORDINATE WITH FIRE MARSHAL FOR PREFERRED LOCATIONS 11 CUT FLOOR (CORE DRILL ON ELEVATED FLOORS) 6'-6" FROM WALL FOR RECEPTACLE & CAT5 FOR CASHWRAP, SEE ELECTRICAL FOR DETAILS. T.G.C. TO OBTAIN L.L. REQUIREMENTS BEFORE CUTTING 12 NEW DEMISING WALL BY LL. G.C. TO INSTALL 5/8" TYPE'X' GYP. BD. ON TENANT SIDE AND PROVIDE BLOCKING AS NECESSARY. 13 MESH WALL GRID BEHIND CASHWRAP. G.C. TO PROVIDE HORIZONTAL BLOCKING @ 24" O.C. SCREW BOTTOM OF MESH TO MITIGATE MOVEMENT FROM WALL. ADJACENT TENANT FINISH LEGEND - COASTAL NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES SEE SEC V. ON CODE STUDY FOR MORE DETAILS. PARTNERS brand: operations: build I Z� ���II 7007 DISCOVER Yi BLVDro DUBLIN, OH 43017 r.) 614.634.7000 T �I 11 tJ W D P A R T N E R S. G O M----.----:—) SEMiN�LE T.C. 200 TOVIINE CENTER CIRCLE SPACE #11311 C SANFOR®, FL 3271 DRAWN BY: WD PROJECT NUMBER FRCC00050 JAI 0 8 lO jjr MARK I DESCRIPTION GENERAL LOCATION VALSPAR SALES AREA WALLS PT -1 CLR: SEA SALT BLUE #: Cl 191 SATIN VALSPAR SERVICE ENTRANCE/ PT -2 CLR: SAWYER WHITE RESTROOM #: 7002-16 INTERIOR SEMI -GLOSS Z_ VALSPAR SALES AREA CEILING Q PT 3 CLR: CREME FRAICHE #: U1200 PT -4 BEHR CLR: SEASIDE SAND STOCK ROOM DOOR/ WOOD FRAME #: 7400-1 OIL BASED SEMI -GLOSS OLYMPIC STOREFRONT PT -5 CLR: HEIRLOOM LACE SYSTEM #: D10-1 4" VINYL BASE STOCK ROOM/ B-1 CLR: BROWN RESTROOM cc 6" WOOD BASE SALES (SUPPLIED SUPPLIED BY FRANCESCA'S, INSTALLED BY G.C. BY FRANCESCA'S) STOREFRONT WALL TILE STOREFRONT 0 WT -1 SOLI USA - HOSI MOSAIC LL CLR: WHITE / MULTI - PATTERN BY OWNER w 0 GROUT: POLYBLEND / CUSTOM CLR: #333 ALABASTER 12"x12" VINYL FLOORING STOCK ROOM/ pC VCT 1 CLR: BEIGE RESTROOM O 0 KARNDEAN SALES � VP 1 VINYL PLANK - HCO3 CLR: DUSK OAK, RANDOM PATTERN SALES/ STOCK ROOM/ CLG-1 NEW 2x2 ACOUSTICAL TILE CEILING DRESSING ROOM/ d TEGULAR EDGE CLR: WHITE RESTROOM J U STOREFRONT C NEW GYP. BD. CEILING NOTE: ALL FINISHES NEED TO MEET A MIN. OF A CLASS C FINISH FOR ENCLOSED SPACES SEE SEC V. ON CODE STUDY FOR MORE DETAILS. PARTNERS brand: operations: build I Z� ���II 7007 DISCOVER Yi BLVDro DUBLIN, OH 43017 r.) 614.634.7000 T �I 11 tJ W D P A R T N E R S. G O M----.----:—) SEMiN�LE T.C. 200 TOVIINE CENTER CIRCLE SPACE #11311 C SANFOR®, FL 3271 DRAWN BY: WD PROJECT NUMBER FRCC00050 JAI 0 8 lO jjr PARTNERS brand - operations: build 7007 DISCOVEF Y BLVD �1 DUBLIN, OH 4317 3;:;. 614.634.7000 T _:_01 WDPARTNERS'.COMc 1I SEMINOLE T.C. 200 TOWNE CENTER CIRCLE_ SPACE #13110 SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 ATTACH STUD FRAMING ATTACH STUD FRAMING z TO STEEL JOIST FRAMING TO STEEL JOIST FRAMING ABOVE PER DETAIL THIS ABOVE PER DETAIL THIS SHEET. DO NOT ATTACH SHEET. DO NOT ATTACH SCREWS A TO METAL DECK. TO METAL DECK. (2)1110-16 I 16" AT EXISTING (2)410-16 SCREWS AT BULKHEAD STUDS. 16" AT EXISTING ' BULKHEAD STUDS. , r1ALL BUILKNEAD -------""� ,'� • /• MALL �• B.O. MALL BULKHEAD 33 MILS BUILKNEAD 3 5/8", 33 MILS EL = 1'L' -1U" , ' �� DIAGONAL BRACE @ 48" O.C. MAX. 5/8„ GYP. BD. OVER , DIAGONAL BRACE @ 48” O.C. MAX. 6" METAL STUD ' --------- _-- FRAMING, PAINT ---------- PT--5 PT --5 ,--, 5/8" GYP. BD. OVER • `------- --- HANG RIGID CEILING WITH #12 CLG. WIRE @ BOX BEAM HEADER: (2) 6005162-33 ------- HANG RIGID CEILING ' 611 METAL STUD 48" O.C. WITH 60OT125--33 TRACKS TSB. WITH 412 CLG. WIRE @ FRAMING, PAINT PT -5 ATTACH TRACK WITH #10-16 SKEWS 48" O.C. (4) #10-16 @ 12" O.C. EACH FLANGE. SUPPORT (4) #10--16 SCREWS, TYP. BOX BEAMS Hrm ONE FULL HT. SCREWS, TYP. STUD 6005162-33 AND ONE BEDDING STUD 6005162-33 TYP. EACH END (.O. STOREFRONT SYSTEM F, ., w. ;, ---- B.O. ENTRY _ _ -- ---- ---- I. a EL - 11'-0" EL = 11'-0" 5/8" GYP. BD. OVER ROLLING GRILLE t ..,.=� . i7 T- _ HITH 600T125-33 TRACKS TSB, 5/8'l GYP. BD. OVER -: FRAMING ' PAINT BEYOND ATTACH TRACK WITH #10-16 SCREWS 3 5/8" METAL STUD PT -5 1 @ 12" O.C. EACH FLANGE. SUPPORT FRAMING, PAINT PT -5 BOX BEAMS WITH ONE FULL HT. WALL TILE (OJT -1) AND MA5TIC ON STUD 6005162-33 AND ONE BEARING 1/2" CEMENT E30ARD. OVER 2 1/2" STUD 6005162-33 TYP. EACH END. METAL STUD FRAMING ROLLING GRILLE WALL TILE (WT -1) ON MASTIC OVER 1/2" COIL CEMENT 50ARD. FRANCESCA'5 WILL COVE LIGHTING, PROVIDE TILES INSTALL 45 AND SNIP TO SITE. DIRECT BY OWNER d SPECIFIED BY WB �I MANUFACTURES RECOMMENDATIONS. �+ EDGE MOUNTED n SIGN BY SIGN VENDOR 6" O I I ALUM. STOREFRONT SYSTEM WITH 1/2" I I , TEMPERED GLAZING I I r I I _ B.O. ENTRY -------- _ B.O. ENTRY EL = 8'-0" EL = 8'-0" 1'—ill (oil TJ 2I -All 'f BOX BEAM HEADER: (2) 5/6" GYP. BD. OVER 6005162--33 WITH 362T125-33 3 5/8" METAL STUD TRACKS TSB. ATTACH TRACK LED CAN LIGHT (E> MErAL DECKING. ATTACH BUILT-UP SECTION TO u FRAMING @ 16 O.C., WITH #10--16 SCREWS @ 12 O.C. (E) s rEEL JOIST TOP CHORD W/ LEASE LINE.----------- TYP. EACH FLANGE. SUPPORT BOX s,LT rOP CHORD. (3)1k12-14 SCREWS, TYP. EA END. (E) r E E L JO _ BEAMS WITH ONE FULL H �. DO NOT PENETRATE ROOF DECK. STUD 3625162-33 AND ONE BEARING STUD 3625162--33 5/8" GYP. BD. OVER TYP. EACH END. 3 5/8" METAL STUD I FRAMING BUILT-UP HEADER: LEASE LINE. (N) 8003162-54 METAL STUD INSIDE OF 8005200.54 METAL ✓ L2x2x68 MILSxO'-8" LONG METAL (N) TRACK. CONNEO'T TOGETHER CLIP ONE SIDE OF DIAD. BRACE W/ USING Ik10.16SCREWS « 6" U.C., (3) #10-16 SCREWS EA LEG, rYP. MAX., `L" FROM EA END. MANUAL ROLL -UP DOOR. SEE AI.I FOR MORE INFO.STEEL TUBE SUPPORT IN WALL - SHOWN DASH[`` POST ...... (N) NEW LIGHTGAGE DIAGONAL (E) SFEEL JOIST BOTTOM CHORD. BRACES @ 48" O.C. 01 BEFORE INSTALLING ANCHORS, CONTRACTOR SHALL VERIFY WITH LANDLORD THAT ATTACHMENT SHOWN IS ACCEPTABLE. BRACING PARALLEL TO ROOF JOISTS. WALL BEYOND WALL BEYOND STOREFRONT BRACING CONNECTION AT FRAMING ABOVE 3 PARTNERS brand - operations: build 7007 DISCOVEF Y BLVD �1 DUBLIN, OH 4317 3;:;. 614.634.7000 T _:_01 WDPARTNERS'.COMc 1I SEMINOLE T.C. 200 TOWNE CENTER CIRCLE_ SPACE #13110 SANFORD, FL 32771 DRAWN BY: WD PROJECT NUMBER FRCC00050 VAV BOX SCHEDULE EXHAUST FAN SCHEDULE TAG MANUFACTURER INLET CFMSIZE O.A. "FAG MAKE MODEL NO. NOTES Sales NOTES DESCRIPTION CFM CFM HP 187 NOTES MANUFACTURER EF -1 SEE ELEC. SEE ELEC. 90 MAX MIN 120/1/60 VAV-1 TRANE VCCF12 12" 1000 300 1, 2 NOTES: 1. FACTORY PROVIDED DISCONNECT SWITCH, CONTROL TRANSFORMER. 2. PROVIDE NEW THERMOSTAT. COORDINATE WITH LANDLORD FOR THERMOSTAT MANUFACTURER AND MODEL INFORMATION. VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 EXHAUST FAN SCHEDULE TAG MANUFACTURER MODEL NOMINAL O.A. FAN VOLTAGE MCA/MOCP NOTES Sales TAG DESCRIPTION CFM CFM HP 187 NOTES MANUFACTURER EF -1 SEE ELEC. SEE ELEC. 90 - 130 WATTS 120/1/60 - 1 NOTES: - - WATER CLOSET 1. CEILING EXHAUST FAN. 90 CFM a 0.375" ESP. FURNISHED WITH FACTORY MOUNTED DISCONNECT AND BACKDRAFT DAMPER. Total (square feet) 954 VALVE COEFFICIENT VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 PLUMBING FIXTURE CH ®ULE Room Name Classification Room Area (sq.ft.) Area OA Rate (cfm/sq.ft.) FIXTURE VALVE/FAUCET People OA Rate (cfm/person) CONNECTIONS Sales Area Sales TAG DESCRIPTION 15 12 7.5 187 NOTES MANUFACTURER MODEL MANUFACTURER MODEL WASTE VENT CW HW Restroorn 64 - - - WATER CLOSET AMERICAN CADET Total (square feet) 954 VALVE COEFFICIENT RA 197 CWR CONDENSER WATER RETURN RD WC -1 ADA STANDARD #2467.016, WHITE RESISTOR DC 4" 2" 3/4" - 1, 2, 3 RTU LAV -1 LAVATORY AMERICAN LUCERNE AMERICAN RELIANT 2" 1-1/2" 1/2" 1/2" 4, 5, 10 SD SUPPLY DIFFUSER ADA STANDARD #0355.012, WHITE STANDARD #7385.050 FIRE ALARM CONTROL PANEL SMD SMOKE DETECTOR FCU FAN COIL UNIT SR FD -1 FLOOR DRAIN JAY R. SMITH 2O05A-P050 TIME CLOCK - 3" 1-1/2" - - 9 UH UNIT HEATER FLOOR CLEAN FAN POWERED BOX SERIES 4000 TO VOLT FSD FIRE SMOKE DAMPER VA VOLT AMPERE GND GROUND VAC FCO OUT JAY R. SMITH SUITE FLOOR FINISH VARIABLE AIR VOLUME HAC HEATED AIR CURTAIN VD VOLUME DAMPER HOA 7 E1N.H-1 POINT -OF. -USE WATER HEATER CI IRONOM,ITE HEATING RELAY WSHP WATER SOURCE HEAT PUMP L LINE VOLTAGE 3/8, ,,: -3/8 ., „ 6.v. EWC-1 WATER COOLER ELKAY EZTL8C - - 2" 1-1/2" 1/2" - 11 NOTES: 1 1. PROVIDE WITH BEMIS MANUFACTURING MODEL 1955SSC STANDARD WHITE OPEN FRONT SEAT. SUPPLY DIFFUSERS ONLY. 4. EXTERNAL FOIL WRAP INSULATION IS DAO O ALL 2. PRESSURE ASSISTED TANK TYPE. REVISIONS REVISION #1: 01-08-2014 3. FURNISH RIGHT AND LEFT HAND MODELS AS REQUIRED PER ADA. 4. PROVIDE WITH JAY R. SMITH #0700 FLOOR MOUNT CONCEALED -ARM LAVATORY CARRIER. 5. PROVIDE WITH TRUEBRO LAV GUARD. 6. 20 AMPS, 208 VOLT SINGLE PHASE, 4160 WATTS, 57°F TEMPERATURE RISE @ 0.5 GPM. 7. PROVIDE POLISHED NICKEL BRONZE COVER WITH ZARB-1470-A CLEANOUT PLUG. 8. CAST IRON CLEANOUT "IEE WITH STAINLESS STEEL ROUND COVER. PLUG TO BE GAS AND WATER TIGHT. - IN CLOSED CEILING AREAS AND NOT 9. PROVIDE FLOOR DRAIN WITH '1/2" TRAP PRIMER AND ACCESS DOOR IN WALL FOR ACCESS. 10. PROVIDE LEONARD 270 THERMOSTATIC MIXING VALVE, ASSE 1017 AND ASSE 1070 RATED. "0 MP 11. PROVIDE WITH DEARBORN 17 GA. TRAP, TRAP ADAPTER, AND ANGLE STOP. WATER COOLER IS 325 WATTS AT 120V, 1 PH, 60HZ. VENTILATION RATE SCHEDULE Mechanical Ventilation Schedules Based upon ASHRAE 62.1, 2007 TAG Room Name Classification Room Area (sq.ft.) Area OA Rate (cfm/sq.ft.) Default Occupancy (4/1000 sq.ft.) Occupancy (#) People OA Rate (cfm/person) Total OA (cfm) Sales Area Sales 804 0.12 15 12 7.5 187 Storage Storage Room 86 0.12 NEW 2424 1 RG -1 room (If ixture) Restroorn 64 - - - - - P�Lt Total (square feet) 954 VALVE COEFFICIENT RA 197 DRAWING LEGEND TAG SUPPLY DIFFUSER DESCRIPTION RETURN GRILLE/ REGISTER TAG MODEL SD -1 AIR DEVICE DESIGNATION 150 CFM TYPE NORMALLY CLOSED EXHAUST FAN / LIGHT COMBO T THERMOSTAT ® SPRINKLER HEAD (E) EXISTING TO REMAIN (R) EXISTING TO BE RELOCATED (N) NEW D AIR DEVICE SCHEDULE TAG MOUNTING DESCRIPTION FINISH MANUFACTURER MODEL SIZE NOTES ANALOG OUTPUT TYPE NORMALLY CLOSED AUX AUXILLIARY NO. NORMALLY OPEN AWG SD -1 LAY -IN SUPPLY WHITE TITUS OMNI 2424 1 RG -1 LAY -IN RETURN WHITE TITUS 50F 2424 2 NOTES: 1. PROVIDE AG -75 DAMPER. 2. 1/2" X 1/2" X 1/2" EGGCRATE RETURN AIR GRILLE. EA10 x1l, A ` = AHU AIR HANDLING UNIT MOD MODULATING Al ANALOG INPUT N NEUTRAL AO ANALOG OUTPUT NC NORMALLY CLOSED AUX AUXILLIARY NO NORMALLY OPEN AWG AMERICAN WIRE GAUGE OA OUTDOOR AIR CD CONTROLDAMPER OL OVERLOAD COM COMMON OVR OVERRIDE CU CONDENSING UNIT PC PHOTOCELL CV CONTROL VALVE PT PROGRAMMABLE THERMOSTAT CV VALVE COEFFICIENT RA RETURN AIR CWR CONDENSER WATER RETURN RD RETURN DIFFUSER CWS CONDENSER WATER SUPPLY RES RESISTOR DC DIRECT CURRENT RG RETURN GRILLE DI DIGITAL INPUT RTU ROOFTOP UNIT DO DIGITAL OUTPUT RVR REVERSING VALVE RELAY EA EXHAUST AIR S TEMPERATURE SENSOR EF EXHAUST FAN SD SUPPLY DIFFUSER EOL END OF LINE SEF SMOKE EXHAUST FAN FACP FIRE ALARM CONTROL PANEL SMD SMOKE DETECTOR FCU FAN COIL UNIT SR SUPPLY REGISTER FD FIRE DAMPER TC TIME CLOCK FDM FLOW DISPLAY MODULE TDM TEMPERATURE DISPLAY MODULE FM FLOWMETER UH UNIT HEATER FPB FAN POWERED BOX V VOLT FSD FIRE SMOKE DAMPER VA VOLT AMPERE GND GROUND VAC VOLT ALTERNATING CURRENT H HOT VAV VARIABLE AIR VOLUME HAC HEATED AIR CURTAIN VD VOLUME DAMPER HOA HAND OFF AUTO WAP WIRELESS ACCESS POINT HR HEATING RELAY WSHP WATER SOURCE HEAT PUMP L LINE VOLTAGE WUH WALL UNIT HEATER LS LIQUID SENSOR X TRANSFORMED MD MINIMUM OR MODULATING DAMPER XMFR TRANSFORMER MIN MINIMUM WMS WIRE MESH SCREEN GENERAL NOTES: 1. CONTRACTOR IS RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING CONDITIONS PRIOR TO 250 SUBMITTING A BID. SUBMISSION OF A BID SERVES AS EVIDENCE THAT THE CONTRACTOR HAS VISITED THE SITE AND HAS ACCOUNTED FOR ALL EXISTING CONDITIONS IN THE BID. 2. BEFORE COMMENCING ANY WORK, CONTRACTOR SHALL REVIEW THE MOST RECENT NATIONAL, 2. STATE, AND LOCAL CODE REQUIREMENTS, AND PERFORM THE WORK IN STRICT ACCORDANCE WITH THESE. 3. CONTRACTOR IS REQUIRED TO READ THE SPECIFICATIONS AND REVIEW THE DRAWINGS FOR ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF ALL SUBCON"TRAC"TORS WITH ALL DIVISIONS OF WORK. 4. CONTRACTOR SHALL ADHERE TO LANDLORD SPECIFICATIONS AND TENANT DESIGN CRITERIA. 5. CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIAL, LABOR, AND SUPERVISION NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH THE SPECIFICATIONS AND STANDARDS AS OPROVIDE OUTLINED HEREIN. 6. UPON COMPLETION OF THE WORK, CONTRACTOR SHALL VERIFY THE PROPER WORKING ORDER OF THE SYSTEM(S) AND MAKE ANY ADJUSTMENTS AS REQUIRED. 7. PROVIDE ALL LOW VOLTAGE CONTROL WIRING FOR THE TEMPERATURE CONTROL SYSTEM. I COORDINATE WITH THE ELECTRICAL CONTRACTOR FOR CONTROL SYSTEM CONDUIT AND POWER 0 REQUIREMENTS. COORDINATE EXACT LOCATIONS WITH THE GC FOR ALL TEMPERATURE CONTROL LANDLORD NOTES: COMPONENTS. 8. THE CONTRACTOR SHALL ENSURE THAT ALL EQUIPMENT, PIPING, AND DUCTWORK, NOT BEING USED \a OR SHOWN TO REMAIN, IS FULLY REMOVED AND NOT ABANDONED. COORDINATE REQUIREMENTS WITH GC AND LANDLORD, VERIFY SCOPE OF WORK WITH GC PRIOR TO BID AND INCLUDE ALL COSTS IN BID. 9. PROVIDE IDENTIFICATION FOR EQUIPMENT LOCATED ON THE ROOF OR OUTSIDE OF THE DEMISED PREMISES. PROVIDE STENCIL WITH A MINIMUM OF 4" HIGH BLACK SPRAY PAINTED LETTERS, INDICATING TENANT'S NAME, HVAC UNIT NUMBER AND SPACE NUMBER. VERIFY ADDITIONAL 0 REQUIREMENTS WITH LANDLORD. 10. ALL RETURN GRILLES IN CONSTRUCTION AREAS MUST BE COVERED WITH FILTER MEDIA WHILE HVAC SYSTEM IS RUNNING. REPLACE FILTER MEDIA WHEN IT GETS DIRTY. 11. CERTIFIED TAB CONTRACTOR TO REBALANCE NEW AND EXISTING AIR DEVICES TO CFM AS DESIGNATED ON PLAN. SPRINKLER N NOTES: 1. FIRE PROTECTION PLANS, SPRINKLER DRAWINGS, MUST BE ENGINEERED AND WET SIGNED BY A 250 LANDLORD APPROVED, LICENSED REGISTERED FIRE PROTECTION CONTRACTOR IN THE LOCAL JURISDICTION. FINAL INSTALLATION MUST COMPLY WITH NFPA 13 AND STATE AND LOCAL AUTHORITIES HAVING JURISDICTION. 2. INS -FALL SPRINKLER HEADS ABOVE AND BELOW DUCTWORK AND OTHER OBSTRUCTIONS AS REQUIRED BY NFPA 13. COORDINATE INSTALLATION OF HEADS WITH HVAC CONTRACTOR AND GC. 3. SPRINKLER HEAD LAYOUT IS A SUGGESTED LAYOUT AND/OR A REPRESENTATION OF THE APPROXIMATE LOCATIONS OF EXISTING HEADS. COORDINATE SPRINKLER HEAD LAYOUT AND PIPE ROUTING WITH ARCHITECTURAL PLANS, STRUCTURAL PLANS, HVAC CONTRACTOR, ELECTRICAL CONTRACTOR, AND GC. THE FIRE SPRINKLER CONTRACTOR SHALL INCLUDE IN THE BID AND BE RESPONSIBLE FOR THE EXACT QUANTITY OF SPRINKLER HEADS REQUIRED FOR COVERAGE AND FINAL APPROVAL. KEYED NOTES: 0 CONNECT NEW SANITARY LINE INTO THE EXIS"f ING SANITARY SERVICE, PROVIDE ADDITIONAL 250 CLEANOUTS AS REQUIRED. FIELD VERIFY EXACT LOCATION AND SIZE OF SANITARY LINE AND INVERT PRIOR TO BID. THIS CONTRACTOR IS RESPONSIBLE FOR ANY CUTTING AND PATCHING OF THE FLOOR THAT MAY BE REQUIRED AS IT RELATES TO THE PLUMBING SCOPE OF WORK. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. CCONNECT NEW COLD WATER LINE INTO THE EXISTING COLD WATER TAP. NOTIFY G.C. IF TAP IS SMALLER THAN SHOWN. REFER TO WATER RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. COORDINATE BACKFLOW PREVENTER REQUIREMENTS WITH LANDLORD AND LOCAL AUTHORITY HAVING JURISDICTION. CONTRACTOR SHALL PURCHASE WATER METER AND REMOTE READER FROM LANDLORD'S TENANT COORDINATOR. INSTALL PER LANDLORD AND LOCAL AUTHORITY'S REQUIREMENTS. OPROVIDE NEW THERMOSTAT FOR VAV-1. COORDINATE MAKE AND MODEL NUMBER WITH PRELIM SET 10 16 2013 LANDLORD TO TIE INTO EXISTING MALL DDC SYSTEM. DEMOLISH EXISTING VAV BOX, VERIFY EXACT LOCATION IN THE FIELD. NEW VAV BOX TO BE INSTALLED IN LOCATION SHOWN. INSTALL VAV BOX IN ACCORDANCE WITH THE MANUFACTURER'S I GUIDELINES AND MAINTAIN ALL REQUIRED SERVICE CLEARANCES. 0 CONNECT NEW MEDIUM PRESSURE DUCT TO EXISTING LANDLORD SUPPLY DUCT SYSTEM. VERIFY LANDLORD NOTES: EXACT LOCATION IN THE FIELD PRIOR TO VAV BOX INSTALLATION. PRIOR TO BID, CONTRACTOR SHALL VISIT THE SITE AND FIELD VERIFY THE EXISTING CONDITIONS \a OF THE SPRINKLER SYSTEM AND DETERMINE EXACT SCOPE/EXTENT OF SPRINKLER MODIFICATIONS WITH LANDLORD AND LOCAL FIRE MARSHAL. INCLUDE ALL COSTS IN BID FOR REQUIRED SPRINKLER MODIFICATIONS. EXISTING SPRINKLER HEADS IN EXISTING CEILINGS CAN BE REUSED WHERE APPROPRIATE. NEW SPRINKLER HEADS SHALL BE INSTALLED IN NEW CEILING OR IN OPEN STRUCTURE AREAS (STOCKROOM) AS REQUIRED. PROVIDE NEW SPRINKLER PIPE AS NEEDED. ENSURE PROPER COVERAGE PER NFPA 13. 0 EXISTING RETURN AIR TRANSFER GRILLE THRU DEMISING WALL SHALL BE REUSED. VERIFY EXACT LOCATION IN THE FIELD. VERIFY EXISTING FIRE DAMPER IS IN COMPLETE WORKING ORDER. REPAIR OR REPLACE AS REQUIRED. PROVIDE NEW POINT OF USE ELECTRIC WATER HEATER. INSTALL AND MAKE PIPING CONNECTIONS PER DETAIL M2-01 ON SHEET M2 AND MANUFACTURER INSTALLATION INSTRUCTIONS, 9L NEW CEILING EXHAUST FAN/LIGHT COMBO BY ELECTRICAL CONTRACTOR. FAN CONTROL SHALL BE WIRED THROUGH THE LIGHT SWITCH SERVING THE RESTROOM. COORDINATE INSTALLATION WITH ELECTRICAL CONTRACTOR. EXTEND 6"0 DUCT FROM THE NEW EXHAUST FAN AND CONNECT TO EXISTING MALL EXHAUST SYSTEM. VERIFY EXACT LOCATION IN THE FIELD. 10 EXTEND NEW VENT PIPING TO MALL VENT SYSTEM. VERIFY MALL VENT SYSTEM LOCATION IN THE FIELD PRIOR TO WORK. REFER TO WASTE AND VENT RISER DIAGRAM AND PLUMBING SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. I M l H a U d 250 ISSUE DATES 4, I� PRELIM SET 10 16 2013 n j I LANDLORD NOTES: \a FINAL SET: 11-6-2013 REST�' �E� ��� 3 > 1. G.C. SHALL VERIFY TRANSFER AIR OPENINGS EXIST AND MEET PE : 11-20-2013 PERMIT SET I•.• MALL CRITERIA FOR VAV/HVAC COMPLIANCE . 3 L. GC SHALL UTILIZE A LL APPROVED CONTRACTOR FOR ALL SD 1 INTERFACE CONNECTIONS TO CURRENT MALL JOHNSON EMS r RU -1=; 6 10':,x'; SYSTEM. CONTACT MALL OPERATIONS TO VERIFY. -- 150 3. EXTERNALLY INSULATED FLEXIBLE DUCT, NOT TO EXCEED 5'-0" IN LENGTH, MAY BE USED FOR VERT"TICAL CONNECTIONS TO 5 1 _ t 8 SUPPLY DIFFUSERS ONLY. 4. EXTERNAL FOIL WRAP INSULATION IS DAO O ALL �] REVISIONS REVISION #1: 01-08-2014 .......... ...-- VD - IN CLOSED CEILING AREAS AND NOT "0 MP 14x12 IN LIEU OF INTERNAL DUCT LINER. ' > s 3 . 3 VAV=1 <UD VD Vp .r.,v . ., ,r.. SurnmerDaily Range............................................................................................... WinterDesign Dry-Bulb........................................................................................... 37.0 IF WinterDesign Wet-Bulb.......................................................................................... 31.1 IF Atmospheric Clearness Number.............................................................................. 0.90 Average Ground Reflectance................................................................................. 0.20 SoilConductivity.................................................................................................... 0.800 BTU/(hr-ft-°F) 50 h WEATHER DATA Design HVAC LOAD CALCULATIONS Time Maximum Zone VAV Air System Information Cooling Design aar% meters: i Air of Air System Narne................................ BLOCK LOAD Number of zones......................................................... . 1 Stock Room 1 Sensible Equipment Class ............................................ UNDEF Floor Area ............................................ ............ 1003.0 ft2 CityName.......................................................................................................... Orlando Area Air System Type .................................................. VAV Location .................................... Orlando, Florida Location.............................................................................................................. Florlda (CFM) Sizing Calculation Information (MBH) Latitude.................................................................................................................... 28.4 Deg. Zone and space: Sizing Method: 944 Longitude 81.3 Deg. Zone CFM .......................... Peak zone sensible load Calculation Months ....................................... Jan to Dec ................................................................................................................. Elevation................................................................................................................ 105.0 ft Space CFM .................. Individual peak space loads Sizing Data ............................................. User -Modified SummerDesign Dry-Bulb........................................................................................ 94.0 IF IF Zane Sizing Data 23.3 Summer Coincident Wet-Bulb.................................................................................. 76.0 79.1: / 67.6 IF Sensible coil load ................................................. 19.8 166 OF 74.5/62.5 `F SurnmerDaily Range............................................................................................... WinterDesign Dry-Bulb........................................................................................... 37.0 IF WinterDesign Wet-Bulb.......................................................................................... 31.1 IF Atmospheric Clearness Number.............................................................................. 0.90 Average Ground Reflectance................................................................................. 0.20 SoilConductivity.................................................................................................... 0.800 BTU/(hr-ft-°F) 50 h Local Time Zone (GMT +/- N hours).......................................................................... . ours Consider Daylight SavingsTime ................................................................................. No Zone Terminal Sizing Data Simulation Weather Data .............................................. .................. noneN/A y ..1.. ,, Y i , I t�.._ ; , . €.. .at"<. =Jr�. a �• :,;� f:,. 'his � y�c�tt�•r Current Data is...................................................................... 2001 ASHRAE Handbook N:.1or?¢:, r€,€ na ,_,r t,c} =.fs. r ; �,s, .€ s,y .>f .., €. Design Cooling Months............................................................... January to December Space Loads and Airflows Zone Name / Space Name Maximum Design Minimum Time Maximum Zone VAV HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 IF / 31.1 IF Cooling Air Air of Heating Floor Stock Room 1 Sensible Flow Flow Peak Load Area Zone Zone Name (MBH) (CFM) (CFM) Load (MBH) (ft2) CFM/ft2 Zone 1 17.3 944 213 Jan 1900 0.0 1003.0 0.94 Local Time Zone (GMT +/- N hours).......................................................................... . ours Consider Daylight SavingsTime ................................................................................. No Zone Terminal Sizing Data Simulation Weather Data .............................................. .................. noneN/A y ..1.. ,, Y i , I t�.._ ; , . €.. .at"<. =Jr�. a �• :,;� f:,. 'his � y�c�tt�•r Current Data is...................................................................... 2001 ASHRAE Handbook N:.1or?¢:, r€,€ na ,_,r t,c} =.fs. r ; �,s, .€ s,y .>f .., €. Design Cooling Months............................................................... January to December Space Loads and Airflows Zone Name / Space Name Mult. Cooling Time Sensible of (MBH) Load Air Heating Flow Load (CFM) (MBH) Floor Area Space (ft2) CFM/ft2 Zone '1 AirSystem Type .................................................. VAV HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 IF / 31.1 IF Location ............................................... Sales 1 13.0 Jan 1900 709 0.0 799.0 0.89 Stock Room 1 3.91 Jan 21001 211 0.0 144.01 1.46 Restroom 1 0.51 Jan 21001 25 0.0 60.01 0.42 HVAC LOAD CALCULATIONS Air System Information • � N -bee of zone 1 Air�,ystern Narne................................ Equipment Class ............................................ BLOCK LOAD UNDEF um ............................................ Floor Area............................................................ I............. 1003.0 ft2 AirSystem Type .................................................. VAV HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 IF / 31.1 IF Location ............................................... Orlando, Florida Sensible Latent Details (BTU/hr) (BTU/hr) Sizing Calculation Information Window & Skylight Solar Loads 0 ft2 0 0 ft2 Zone and Space Sizing Method; 0 ft2 0 0 ft2 0 Roof Transmission Zone CFM .......................... Peak zone sensible load 0 ft2 0 Calculation Months ....................................... Jan to Dec 0 ft2 0 Space CFM .................. Individual peak space loads Sizing Data .............................................. User -Modified Central Cooling Coil Sizing Data Door Loads 0 ft2 0 0 ft2 0 Total coil load ......................................................... 1.9 Tons Load occurs at ................................................. Jan 1300 Totalcoil load ....................................................... 23.3 MBH OA DB / WB ................................................... 79.1: / 67.6 IF Sensible coil load ................................................. 19.8 MBH Entering DB / WB ........................................... 74.5/62.5 `F Coil CFM at Jan 1300 ............................................ 944 CFM Leaving DB ! WB ........................................... 55.0/53.9 IF Maxblock CFM ..................................................... 944 CFM Coil ADP.................................................................. 52.8 IF Sum of peak zone CFM ......................................... 944 CFM Bypass Factor........................................................ 0.100 0 Sensible heat ratio .............................................. 0.851 0 Resulting RH.............................................................. 52 % ft2/Ton................................................................. 516.9 - 0 Design supply ternp................................................. 55.0 IF BTU/(hr-ft2)........................................................... 23.2 0 Zone T -stat Check ................................................. 0 of 1 OK Water flow @ 10.0 IF rise ..................................... 4.66 gpin Max zone temperature deviation ................................ 0.7 IF Supply Fan Sizing Data Plenum Wall Load 0% 0 - 0 0 Actual max CFM .................................................... 944 CFM Fan motor BFIP........................................................ 0.10 BHP StandardCFM ....................................................... 940 CFM Fan motor kW .......................................................... 0.08 I<W Actual max CFM/ft2............................................... 0.94 CFM/ft2 Fan static................................................................. 0.75 in wg Outdoor Ventilation Air Data 0 Supply Fan Load 944 CFM 283 213 CFM -99 Design airflow CFM .................................................. 0 CFM CFM/person............................................................. 0.00 CFM/person CFM/ft2.................................................................0.00 0% 0 CFM/ft2 01/. 0 - >> Total System Loads DESIGN COOLING DESIGN HEA11N01 COOLING DATA AT Jan 1300 COOLING OA DB / WB 79.6'F/67.6'F HEATING DATA AT DES HTG HEATING OA DB / WB 37.0 IF / 31.1 IF ZONE LOADS Sensible Latent Details (BTU/hr) (BTU/hr) Sensible Latent Details (BTU/hr) (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 0 ft2 Wall Transmission 0 ft2 0 0 ft2 0 Roof Transmission 0 ft2 0 0 ft2 0 Window Transmission 0 ft2 0 0 ft2 0 Skylight Transmission 0 ft2 0 0 ft2 0 Door Loads 0 ft2 0 0 ft2 0 Floor Transmission 1003 ft2 0 1003 11:2 0 - partitions 0 ft2 0 0 ft2 0 - Ceiling 0 f 0 0 ft2 0 Overhead Lighting 1059 W 2925 0 0 Task Lighting 1598 W 4341 0 0 Electric Equipment 1250 W 4197 - 00 People 15 2498 3007 0 0 0 Infiltration - 0 0 0 0 Miscellaneous 0 0 - 0 0 Safety Factor 15% /15% 2094 451 10% 0 0 .,> Total Zone Loads 16055 3458 0 0 Zone Conditioning 19544 3458 - -1709 0 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 01/. 0 0 0 Plenum Lighting Load 0°/ 0 00 Return Fan Load 944 CFM 0 213 CFM 0 Ventilation Load 0 CFM 0 0 0 CFM 0 0 Supply Fan Load 944 CFM 283 213 CFM -99 - Space Fan Coil Fans - 0 0 Duct Heat Gain / Loss 0% 0 01/. 0 - >> Total System Loads 19827 3458 -1808 0 Central Cooling Coil 19827 3458 -1808 0 , Total Conditioning 19827 3458 -1808 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads ELECTRICAL COMMENTS: • ABSOLUTELY NO FLEXIBLE CONDUIT IS PERMITTED IN DEMISING WALLS. FLEXIBLE CONDUIT IS PERMITTED FOR SHORT, FINAL CONNECTIONS ONLY (6'-0" OR LESS). • EXPOSED CONDUIT SHALL BE INSTALLED IN STRAIHGT LINES, PARALLEL OR IN RIGHT ANGLES TO THE BUILDING STRUCTURE. DO NOT LOOP EXCESS FLEXIBLE CONDUIT IN CEILING SPACE OR WALL CAVITY. • CABLE TYPES AC OR NM CABLES ARE NOT ACCEPTABLE. TYPE MC CABLE, ELECTRIC METALLIC TUBING (EMT), AND RIGID GALVANIZED CONDUIT ARE PERMITTED. • ALL EQUPMENT, DEVICES, AND FIXTURES SHALL BE GROUNDED IN COMPLIANCE WITH NEC AND UL REQUIREMENTS. • ALL PANELS TO BE UI. LABELED WITH BOLT -ON TYPE CIRCUIT BREAKERS. • 7 -DAY, 24-HOUR TIME CLOCK IS REQUIRED TO CONTROL STOREFRONT ENRTY LIGHTS, SHOW WINDOW, SHOW WINDOW LIGHTS, SHOW WINDOW RECEPTACLES, AND STOREFRONT SIGNAGE. ILLUMINATED STOREFRONT SIGNS MUST REMAIN LIT DURING ALL MALL BUSINESS HOURS. • TENANT IS REQUIRED TO MAKE A FIELD SURVEY OF THE EXISTING ELECTRICAL SERVICE TO ENSURE THAT THE TOTAL CONNECTED LOAD DOES NT EXCEED THE ELECTRICAL SERVICE. ANY/ALL MODIFICATIONS OR UPGRADES NEEDED ARE SUBJECT TO LANDLORD'S PRIOR APPROVAL, AND WILL BE COMPLETED BY TENANT/TENANT'S G.C., AT TENANT'S SOLE EXPENSE. • ALL ELECTRICAL PANELS TO BE MOUNTED ON PLYWOOD BACKER BOARD. • PANEL PHASE LOADS TO BE BALANCED WITHIN 10%. • ELECTRICAL PANELS MAY NOT BE RECESSED IN DEMISING PARTITIONS, SURFACE MOUNT OR FUR OUT WALL TO ACHIEVE FLUSH APPEARANCE. • ONLY 30KVA AND SMALLER TRANSFORMERS MAY BE SUSPENDED FROM BUILDING STRUCTURE, ALL OTHER TRANSFORMERS NUST BE FLOOR MOUNTED. • FLOOR PENETRATIONS TENANT'S G.C. MUST ADVISE THE PROPERTY'S OPERATIONS DIRECTOR PRIOR TO ANY SLAB CUTTING OR REMOVAL. ALL FLOOR PENETRATIONS MUST BE CORE -BORED OR SAW -CUT (NO JACK-HAMMERIN(3 PERMITTED). PRIOR TO WORK, TENANT'S G.C. MUST VERIFY THAT TENANT'S WORK WILL NOT CONFLICT WITH EXISTING, STRUCTURAL, UTILITY, OR OTHER UNDER SLAB CONDITIONS. TENANT'S WORK MUST NOT COMPROMISE OR DAMAGE THE EXISTING STRUCTURE. ANY DAMAGE CAUSED BY TENANT'S WORK IS TO BE REPAIRED AT TENANT'S EXPENSE. E r....A 20,22 1 y; # ...w..,.... , WH -1 .. 1 A 10 i ...... ., 3� t9 , w 1 _ t A-8 I 1r?(_),!AT "B., 1 6+ Ll A-1 5 ) A 12 +1 1 13 I J A-4,6 ...... ....z@ ;1 ,., g {.„......a 60A DISC 3SV1 = 1 ` 30KVA XFMR 1 POINT "A” I A2 ....... ... t...r.......... ..... . A-10 E OEM 1 POWER PLAN mm SCALE: 1/4"=V-0" .0 3 : ADJACENT TENANT t " .... _ ..... . 13 t .- 1 I 10 1 C�11 +14" ° A-18 A-17 u' -12 VIA SW. 'T' � E t E # I �.. S. ........... ..y..... � . „ .........E ,ntS .... e.� ........ ;: ..nc 3 A-17 A-24' _, POINT "C" #i �} t4 PANEL A t 13 !�I VIA=eSW f" A 1zdb+14" j IIA 18((1 1::.. ADJACENT TENANT A-14,16 0VIA SW. '1' 11 A 18 } 1� 3 A -1l A-12kh+14" ELECTRICAL SYMBOLS LIST_ STANDARD 20A, 120/277V-10 SPST TOGGLE SWITCH MOUNTED AT +48" A.F.F. $OS WALL MOUNTED INFRA -RED OCCUPANCY SENSOR. OS CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR. W STANDARD 20A, 120V-10 GROUNDING TYPE SIMPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-16 GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. &.P STANDARD 20A, 120V-10 GROUNDING TYPE WEATHER PROOF (NEMA 3R) DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE CEILING MOUNTED AT STORE FRONT STANDARD 20A, 120V-10 GROUNDING TYPE FOUR-PLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE "GROUND FAULT INTERRUPTER" (G.F.I.) RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE DUPLEX RECEPTACLE,MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE QUADRAPLEX RECEPTACLE,MOUNTED AT+18" A.F.F. STANDARD 15A, 120V-10 SIMPLEX CLOCK RECEPTACLE. Ke LM FUSED DISCONNECT SWITCH. AMPS, POLES AND FUSE SIZE AS INDICATED. OPEN- INDICATES NON-FUSED W.P. - INDICATES NEMA 3R ENCLOSURE L® COMBINATION DISCONNECT SWITCH/MAGNETIC MOTOR STARTER. AMPS, POLES, FUSE SIZE, AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE. ® MAGNETIC MOTOR STARTER. POLES AND NEMA SIZE AS INDICATED, PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE MANUAL MOTOR STARTER SWITCH. HORSEPOWER RATED -120V - 10 -U.O.N. M PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. O JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND/OR CONDUCTORS PASSING THRU. MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. TRANSFORMER AS SPECIFIED. © TIME CLOCK. DELIVERY BUZZER. DELIVERY BUZZER PUSH BUTTON MOUNTED AT 54" A.F.F. TELEPHONE PLYWOOD BACKBOARD. Q THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE J -BOX AT +48" A.F.F. (� VOLUME CONTROL MOUNTED AT +48" AFF. Y® TELEPHONE OUTLET WITH (1) RJ11 PORT. JACK COLOR - GRAY. XV DATA OUTLET WITH RJ45 PORTS (X) AMOUNT OF DATA PORTS. JACK COLOR - ORANGE. ® COMBINATION TELE/DATA OUTLET WITH (1) RJ11 AND AND (2) RJ45 PORTS. JACK COLOR - GRAY AND ORANGE. ® TELEPHONE OUTLET WITH (1) RJ11 PORT WITH TWO TELEPHONE LINES. JACK COLOR - BLUE. CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. CONDUIT ROUTED BELOW FINISHED GRADE AND / OR CONCRETE SLAB. HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. FLEXIBLE CONDUIT CONNECTION FROM JUNCTION BOX. GENERAL ELECTRICAL SAFETY REQUIREMENTS: A. ALL ELECTRICAL WORK PRACTICES MUST COMPLY WITH APPLICABLE SECTIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL ELECTRICAL CODE (NFPA 70 & 70E), NATIONAL ELECTRICAL SAFETY CODE (NESC) AND STATE AND LOCAL ADOPTED ELECTRICAL CODES. B. THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND ALL APPLICABLE TRADES ARE RESPONSIBLE STRICT TRICT ADHERENCE TO ALL ELECTRICAL SAFETY REQUIREMENTS. - LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR CUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. • NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. FIRE ALARMSYSTEM YM L r "• d��i,�S/U•• ir� % FRCP I FIRE CONTROL PANEL +72" A.F.F. TO TOP OF DEVICE RPS REMOTE POWER SUPPLY +72" A.F.F. TO TOP OF DEVICE F-F—TC-1 FIRE TERMINAL CABINET FSA FIRE SYSTEM ANUNCIATOR +48" A.F.F. TO TOP OF DEVICE Zc CONTROL MODULE Zr RELAY MODULE CONTROL RELAY, SPDT, W/ LED �j MONITOR MODULE a PULL STATION +48" A.F.F. TO TOP OF DEVICE QTS WATER FLOW SWITCH 40 TAMPER SWITCH DH DOOR HOLD OPEN DEVICE B. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR "THRU-WIRING" 24VDC HORN +90" A.F.F. TO TOP OF DEVICE R1 SUPERVISION RELAY O L DETECTOR 120 VAC W/9VDC BATTERY O PHOTOELECTRIC SENSOR 3 : ADJACENT TENANT t " .... _ ..... . 13 t .- 1 I 10 1 C�11 +14" ° A-18 A-17 u' -12 VIA SW. 'T' � E t E # I �.. S. ........... ..y..... � . „ .........E ,ntS .... e.� ........ ;: ..nc 3 A-17 A-24' _, POINT "C" #i �} t4 PANEL A t 13 !�I VIA=eSW f" A 1zdb+14" j IIA 18((1 1::.. ADJACENT TENANT A-14,16 0VIA SW. '1' 11 A 18 } 1� 3 A -1l A-12kh+14" ELECTRICAL SYMBOLS LIST_ STANDARD 20A, 120/277V-10 SPST TOGGLE SWITCH MOUNTED AT +48" A.F.F. $OS WALL MOUNTED INFRA -RED OCCUPANCY SENSOR. OS CEILING MOUNTED ULTRASONIC OCCUPANCY SENSOR. W STANDARD 20A, 120V-10 GROUNDING TYPE SIMPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-16 GROUNDING TYPE DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. &.P STANDARD 20A, 120V-10 GROUNDING TYPE WEATHER PROOF (NEMA 3R) DUPLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE DUPLEX RECEPTACLE CEILING MOUNTED AT STORE FRONT STANDARD 20A, 120V-10 GROUNDING TYPE FOUR-PLEX RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 GROUNDING TYPE "GROUND FAULT INTERRUPTER" (G.F.I.) RECEPTACLE MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE DUPLEX RECEPTACLE,MOUNTED AT +18" A.F.F. STANDARD 20A, 120V-10 ISOLATED GROUND TYPE QUADRAPLEX RECEPTACLE,MOUNTED AT+18" A.F.F. STANDARD 15A, 120V-10 SIMPLEX CLOCK RECEPTACLE. Ke LM FUSED DISCONNECT SWITCH. AMPS, POLES AND FUSE SIZE AS INDICATED. OPEN- INDICATES NON-FUSED W.P. - INDICATES NEMA 3R ENCLOSURE L® COMBINATION DISCONNECT SWITCH/MAGNETIC MOTOR STARTER. AMPS, POLES, FUSE SIZE, AND NEMA SIZE AS INDICATED. PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE. ® MAGNETIC MOTOR STARTER. POLES AND NEMA SIZE AS INDICATED, PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION PER MOTOR NAMEPLATE DATA, 120V CONTROL COIL - U.O.N., AND H.O.A. (HAND -OFF -AUTO) SWITCH. W.P. - INDICATES NEMA 3R ENCLOSURE MANUAL MOTOR STARTER SWITCH. HORSEPOWER RATED -120V - 10 -U.O.N. M PROVIDE COMPLETE WITH THERMAL OVERLOAD PROTECTION. O JUNCTION BOX. SIZED BY THE CONTRACTOR PER ACTUAL NUMBER OF CONDUITS AND/OR CONDUCTORS PASSING THRU. MOTOR OUTLET. H.P. OR F.L.A. - VOLTS & PHASE AS INDICATED. TRANSFORMER AS SPECIFIED. © TIME CLOCK. DELIVERY BUZZER. DELIVERY BUZZER PUSH BUTTON MOUNTED AT 54" A.F.F. TELEPHONE PLYWOOD BACKBOARD. Q THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. PROVIDE J -BOX AT +48" A.F.F. (� VOLUME CONTROL MOUNTED AT +48" AFF. Y® TELEPHONE OUTLET WITH (1) RJ11 PORT. JACK COLOR - GRAY. XV DATA OUTLET WITH RJ45 PORTS (X) AMOUNT OF DATA PORTS. JACK COLOR - ORANGE. ® COMBINATION TELE/DATA OUTLET WITH (1) RJ11 AND AND (2) RJ45 PORTS. JACK COLOR - GRAY AND ORANGE. ® TELEPHONE OUTLET WITH (1) RJ11 PORT WITH TWO TELEPHONE LINES. JACK COLOR - BLUE. CONDUIT CONCEALED WITHIN BUILDING WALLS OR CEILING SPACE. CONDUIT ROUTED BELOW FINISHED GRADE AND / OR CONCRETE SLAB. HOMERUN TO DESTINATION AS INDICATED. REFER TO CONDUIT SYMBOL ABOVE. FLEXIBLE CONDUIT CONNECTION FROM JUNCTION BOX. GENERAL ELECTRICAL SAFETY REQUIREMENTS: A. ALL ELECTRICAL WORK PRACTICES MUST COMPLY WITH APPLICABLE SECTIONS OF THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA), NATIONAL FIRE PROTECTION ASSOCIATION (NFPA), NATIONAL ELECTRICAL CODE (NFPA 70 & 70E), NATIONAL ELECTRICAL SAFETY CODE (NESC) AND STATE AND LOCAL ADOPTED ELECTRICAL CODES. B. THE GENERAL CONTRACTOR, ELECTRICAL CONTRACTOR AND ALL APPLICABLE TRADES ARE RESPONSIBLE STRICT TRICT ADHERENCE TO ALL ELECTRICAL SAFETY REQUIREMENTS. - LANDLORD REQUIREMENTS: • ALL HOME RUNS TO TENANT'S PANELS SHALL BE IN RIGID STEEL CONDUIT OR EMT. • ALL EXPOSED WIRING IN CEILINGS OR INTERIOR WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • ALL WIRING IN LANDLORD DEMISING WALLS MUST BE IN RIGID STEEL CONDUIT OR EMT. • COORDINATE ALL FLOOR CUT MEANS AND METHODS OF ROUTING CONDUIT THROUGH THE FLOOR WITH MALL OPERATIONS. • NO CONDUIT TO BE SUPPORTED FROM THE ROOF DECK. VERY EXACT LOCATION WITH OWNER. G.C. TO INSTALL STEREO AND RUN SPEAKER WIRE, G.C. TO RUN WIRE BEHIND FURNITURE, SPEAKERS WD PROJECT NUMBER INSTALLED ON FOP OF FURNITURE TO RIGHT AND LEFI OF BACK CASHWRAP. SPEAKERS TO MUTE WHEN FIRE ALARM IS ACTIVATED. G.C. TO FRCC00050 VERIFY ALL REQUIREMENTS WITH LANDLORD AND TO COORDINATE WITH FIRE ALARM CONTRACTOR AS REQUIRED. DUPLEX RECEPTACLE WITH COVER PLATE MOUNTED IN SOFFIT ABOVE WINDOW. CONTROL RECEPTACLE WITH TIME CLOCK AND SWITCHES AT MANAGER'S DESK. RECEPTACLE AND COVER PLATE TO MATCH �����As{aaaaaae�®d SURROUNDING WALL COLOR. .,��' 4.H�`�� o9d cam. 4 NEW PANEL "A" 208Y/1 20V, 3PH, 4W WITH A 100A MAIN CIRCUIT BREAKER. �.,\\ G E N �� "•.,'y ���� REFER TO SHEET E-3 FOR MORE DETAIL. _ No 6 '. AN 5 NEW TIME CLOCK FOR LIGHTING AND RECEPTACLES. REFER TO SHEETE2 0 =_ FOR MODEL NUMBER. COORDINATE EXACT LOCATION PRIOR TO BID. O2' X 4' X 3/4" TELECOMM. BOARD WITH DEDICATED QUADRAPLEX r'",~ %STATE OF r RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM L AL TELEPHONE "o" OB �•••���" GENERAL N r "• d��i,�S/U•• ir� % COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULL WIRE FROM IN A. THE CONTRACTOR FOR THIS WORK IS REQUIRED TO READ THE PSB u SPECIFICATIONS REVIEW DRAWINGS OF ALL DIVISIONS OF WORK AND IS RESPONSIBLE FOR THE COORDINATION OF THIS WORK AND THE WORK OF PARTNERS ALL SUBCONTRACTORS WITH ALL DIVISIONS OF WORK. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ALL SUBCONTRACTORS ISSUE GATES 40 WITH A COMPLETE SET OF BID DOCUMENTS. E PRELIM SET: 10-16-2013 B. CIRCUITING INDICATED ON PLAN IS PARTIALLY DIAGRAMMATIC FOR "THRU-WIRING" band op�r�tl®ns build CLARITY. CIRCUITING SHALL BE WHERE AND WHENEVER 0 FINAL SET: 11-6-2013 POSSIBLE. PERMIT SET: 11-20-2013 C. FIELD VERIFY EXACT LOCATION AND ELECTRICAL REQUIREMENTS OF ALL HVAC EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING 7007 DISCOVERY BLVD ELECTRICAL EQUIPMENT. DUBLIN, OH 43017 't D. ALL RECEPTACLE CIRCUITS UP TO 100'-0" SHALL UTILIZE #12 CONDUCTORS 614.634.7000 T I 10 D1 Ar GnnGnrr nP ni iAn PP:C'PPTA('.1 F ANn WIRF R0[ ITINCa WITH MILLWORK MINIMUM. ALL RECEPTACLE CIRCUITS FROM 101'-0" TO 150'-0" IN LENGTH SHALL UTILIZE #10 CONDUCTORS MINIMUM. CIRCUITS ABOVE 251'-0" SHALL WDPARTNERS.CON UTILIZE #6 CONDUCTORS MINIMUM. I E. PLACEMENT OF ALL RECEPTACLES IN THE "SALES" AREA SHALL BE c� INTENTIONAL (I.E. - CENTERED ON COLUMNS, WALL FEATURES OR TIGHT- TO CORNERS AND AT 18" A.F.F UNLESS OTHER WISE NOTED). IF THE I RECEPTACLE IS NOT SHOWN IN A DESIRABLE LOCATION, FIELD VERIFY EXACT PLACEMENT OF RECEPTACLE WITH TENANT'S PROJECT MANAGERiii g 111 111glig 11 g! all ggw�g PRIOR TO ROUGH -IN. F. ELECTRICAL CONTRACTOR SHALL MAKE ALL FINAL CONNECTIONS AS REQUIRED FOR A FULLY COMPLETE AND OPERABLE SYSTEM. G. WHERE DRYWALL CEILINGS ARE USED IN THE "SALES" AREA, THE SEMINOLE T.C. ELECTRICAL CONTRACTOR SHALL ARRANGE CIRCUITS TO AVOID THE USE OF JUNCTION BOXES IN INACCESSIBLE LOCATIONS. THE USE OF JUNCTION 200 TOWNS CENTER CIRCLE BOXES ABOVE LAY -IN CEILINGS ARE ACCEPTABLE. SPACE #1311C H. ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INQUIRE WITH THE LANDLORD'S REPRESENTATIVE ON ANY FIRE ALARM SYSTEMS IN USE AT SANFORD, FL 32771 THE MALL AT THE TIME OF THE BID. IF THE FIRE ALARM SYSTEM IS NOT ADEQUATELY DESCRIBED ON THE DRAWINGS, THE ELECTRICAL CONTRACTOR IS RESPONSIBLE TO INFORM THE GENERAL CONTRACTOR AND INCLUDE THE COST AS A SEPARATE LINE ITEM IN THE BID. NO ADDITIONAL MONEY SHALL BE AWARDED FOR TIE-IN REQUIREMENTS TO A LANDLORD'S FIRE ALARM SYSTEM THAT IS IN EXISTENCE AT THE TIME OF THE BID, WITHOUT A SEPARATE LINE ITEM FOR THE FIRE ALARM SYSTEM AT THE TIME OF THE BID. I. INSTALL ENGRAVED BAKELITE NAMEPLATE ON SERVICE DISCONNECT" SWITCH IN LANDLORD'S SWITCH GEAR WITH DEMISED PREMISES' SPACE NUMBER. IA J. NO HANGERS, SUPPORTS, JUNCTION BOXES, ETC. SHALL BE ATTACHED TO ROOF DECK.. K. COORDINATE ALL ROOF PENETRATIONS WITH THE LANDLORD. WRITTEN PERMISSION FROM THE LANDLORD SHALL BE RECEIVED PRIOR TO ANY WORK BEING PERFORMED. ALL ROOF PENETRATIONS TO BE BY LANDLORD'S CONTRACTOR AT TENANT'S ELECTRICAL CONTRACTOR'S EXPENSE. L. ELECTRICAL CONTRACTOR IS TO CUT FLOOR (CORE DRILL ON ELEVATED FLOORS) AS REQUIRED TO INSTALL CONDUITS TO CASHWRAP UNITS AND PATCH FLOOR TO MATCH EXISTING. COORDINATE ALL WORK WITH LANDLORD PRIOR TO STARTING WORK. $> M. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL TYPE WRITTEN PANEL DIRECTORIES IN ALL PANEL BOARDS. N. ALL RECEPTACLES TO BE MOUNTED VERTICALLY, NOT HORIZONTALLY. O. RECEPTACLE COVER PLATES SHALL BE WHITE EXCEPT AT WAINSCOT, WHERE THEY SHALL BE IVORY P. "G.C. IS TO REVIEW STRUCTURE BELOW OUR SPACE PRIOR TO CONSTRUCTION FOR CONDITIONS PREVENTING FLOOR PENETRATIONS AS SHOWN. OBSTRUCTIONS THAT PREVENT LAYOUT AS SHOWN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY AND PRIOR TO FRAMING." KEYED . OCROSSCOM TO RUN TWO (2) CAT5E WIRES BETWEEN POINTS "A" & "B", 1 BETWEEN POINTS "B" AND "C", AND BETWEEN POINTS "C" AND "A'. COORDINATE ALL ROUTING PRIOR TO ROUGH -IN. 2 PROVIDE RECEPTACLE AT BACK CASH WRAP FOR STEREO EQUIPMENT, DRAWN BY: VERY EXACT LOCATION WITH OWNER. G.C. TO INSTALL STEREO AND RUN SPEAKER WIRE, G.C. TO RUN WIRE BEHIND FURNITURE, SPEAKERS WD PROJECT NUMBER INSTALLED ON FOP OF FURNITURE TO RIGHT AND LEFI OF BACK CASHWRAP. SPEAKERS TO MUTE WHEN FIRE ALARM IS ACTIVATED. G.C. TO FRCC00050 VERIFY ALL REQUIREMENTS WITH LANDLORD AND TO COORDINATE WITH FIRE ALARM CONTRACTOR AS REQUIRED. DUPLEX RECEPTACLE WITH COVER PLATE MOUNTED IN SOFFIT ABOVE WINDOW. CONTROL RECEPTACLE WITH TIME CLOCK AND SWITCHES AT MANAGER'S DESK. RECEPTACLE AND COVER PLATE TO MATCH �����As{aaaaaae�®d SURROUNDING WALL COLOR. .,��' 4.H�`�� o9d cam. 4 NEW PANEL "A" 208Y/1 20V, 3PH, 4W WITH A 100A MAIN CIRCUIT BREAKER. �.,\\ G E N �� "•.,'y ���� REFER TO SHEET E-3 FOR MORE DETAIL. _ No 6 '. AN 5 NEW TIME CLOCK FOR LIGHTING AND RECEPTACLES. REFER TO SHEETE2 0 =_ FOR MODEL NUMBER. COORDINATE EXACT LOCATION PRIOR TO BID. O2' X 4' X 3/4" TELECOMM. BOARD WITH DEDICATED QUADRAPLEX r'",~ %STATE OF r RECEPTACLE AND CIRCUIT WITH ISOLATED GROUND. VERIFY SYSTEM L AL TELEPHONE "o" OB �•••���" GROUNDING AND ALL OTHER REQUIREMENTS WITH OC r "• d��i,�S/U•• ir� % COMPANY. EXTEND 1" TELEPHONE CONDUIT WITH PULL WIRE FROM SERVICE ENTRANCE AT DEMISING WALL TO TELECOMM. BOARD. VERIFY PSB u EXACT LOCATION IN FIELD. SEE SHEET E3 FOR FRANCESCA'S NOTES AND DETAILS. RECEPTACLE, DATA AND TELEPHONE OUTLET MOUNTED IN CASHWRAP MILL WORK. COORDINATE EXACT PLACEMENT" OF DEVICE AND WIRE ISSUE GATES 40 ROUTING IN CASHWRAP WITH MILLWORK DRAWINGS. E PRELIM SET: 10-16-2013 (1) 1" CONDUIT FOR POWER AND (1) 1" CONDUITS FOR TELEPHONE/DATA 8 UNDERFLOOR FROM CASHWRAP TO NEARBY WALL OR COLUMN, UP TO 0 FINAL SET: 11-6-2013 ABOVE CEILING AND TO ELECTRICAL PANEL OR TELEPHONE BOARD AS PERMIT SET: 11-20-2013 LABELED. STUB CONDUITS UP 16" ABOVE FINISHED FLOOR AT CASHWRAP. SEE E3 FOR FRANCESCA'S NOTES AND DETAILS. ELECTRIC WATER HEATER. CIRCUIT AS SHOWN. PROVIDE WHIP AT 8'-6" AFF FOR FURNITURE. COORDINATE EXACT 10 D1 Ar GnnGnrr nP ni iAn PP:C'PPTA('.1 F ANn WIRF R0[ ITINCa WITH MILLWORK RF���S�C1NS NEC ELECTRICAL LOAD SUMMARY SIZE: 100 AMP MCB ELECTRICAL LOAD OPTIONS: NONE NEMA: 1 CONNECTED NEC DEMAND USE NEC REFERENCE LIGHTING ZONE -L1 VA/FT2 0.00 730 913 NEUTRAL: 100% TVSS: NO 220.12,42 LIGHTING ZONE -1_2 VA/FT2 0.00 _ 0 0 w 220.12,42 LIGHTING ZONE13 VA/FT2 0.00 0 0 KW PER PHASE 220.12,42 TRACK - TL (FT) 96 952 6,840 Oc 220.43(6) SIGNS - S (EA) 1 1,000 1,250 220.14(F) SHOW WINDOW - SW (FT) DESCRIPTION 0 0 220.14(G),43(A) RATINGLU DF = DIVERSITY FACTOR RECEPTACLES - R 3,780 3,780 100% 220.14(H,I & K),44 KITCHEN RESISTIVE - KR 2,100 2,100 100% 220.56 KITCHEN MOTORS - KM 0 0 100% 220.56 COOLING MOTORS - C �0 0 100% 220,40,50,60 HEATING - H 0 0 100% 100% 220.40,50,51,60 OTHER MOTORS - OM MAX MOTOR HP 0 0 N/A 0 0 220.40,50 220.40,50 WATER HEATERS - WH 4,160 4,160 100% 220.40 OTHER - 0 100 100 100% 220.40 RECEPT. MGR'S DESK R 3.0 1 TOTAL KW 12.8 19.1 POWER FACTOR: 99% 1 LIGHTING AREA - Al TL FT2 LIGHTING - L1 0.00 W/FT2 LIGHTING AREA - A2 FT2 LIGHTING - L2 0.00 WlFT2 LIGHTING AREA - A3 FT2 LIGHTING - L3 0.00 W/FT2 - LIGHTING AREA 0 FT2 TOTAL LIGHTS: 0.00 W/FT2 COOLING AREA 0 FT2 COOLING - C 0.00 W/ T2 HEATING AREA 0 FT2 HEATING - H 0.00 W/FT2 MICROWAVE CONNECTED: 0.00 W/FT2 NEC DEMAND: 0.00 W/FT2 SYSTEM VOLTAGE: 480 VOLTS PHASES: 3 TL CONNECTED: 15.6 AMPS j NEC DEMAND: 23.3 LAMPS MOTOR CONTRIBUTION: 0.0 KW CONFIGURATION: 3 PHASE 4 WIRE PANELBOARD: A SIZE: 100 AMP MCB FEEDER: # 3 W/#8 G IN 11/4" C CU SETS: 1 OPTIONS: NONE NEMA: 1 SERVICE ENTRANCE: NO LENGTH: 50 FT CONDUIT TYPE: ST TYPE: LIGHTING & APPLIANCE VOLTAGE DROP: 0.39% FOR FAILURE TO COMPLY. PARTNERS B. MOUNTING: SURFACE VOLTAGE: 208Y/120V CONFIG: 3 PHASE 4 WIRE NEUTRAL: 100% TVSS: NO LOCATION: ELECTRIC ROOM FED FROM: DP DIRECTION: TOP BRANCH MOUNT: BOLT -ON BUS MATERIAL: CU CIRCUIT OC w Q, Lu a w � EQUIPMENT PROVIDED BY OTHERS (INCLUDING HVAC EQUIPMENT) PRIOR TO ROUGH -IN AND KW PER PHASE KW PER PHASE PROVIDE ALL REQUIRED FUSIBLE SWITCHES, TRANSFORMERS, STARTERS NECESSARY FOR w w cn cn Oc CIRCU IT NO. RATING o LIN, OH DUBOH43Q17 o DESCRIPTION DESCRIPTION o ;I c�j 0 RATINGLU N0. FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. f o I H. _ ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL -A FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING AUTHORITY. A B C A g C 1 20 1 2.1 L1 LTG - SALES _ 0.25 0.36 _ RECEPT. MGR'S DESK R 3.0 1 20 2 3 20 1 3.8 TL LTG - SALES TRACK 0.43 0.60 -_ REFRIGERATOR KR` 5.0 1 20 4 5 20 1 1.9 L1 _ LTG DECORATIVE 0.21 _ f___ 1.50 MICROWAVE KR 12.5 1 20 6 7 - 20 1 4.5 TL LTG SALES TRACK _ 0.52 -_ 0,36 RECEPT. - PHONE BOARD R 3.0 1 20 8 9 20 1 4.5 .0 WATER FOUNTAIN / 0.54 !<� 0.54 ''= '� RECEPT. - BOH R 4.5 1 20 10 11 20 .. 1 1.5 R RECEPT. - BACKWRAP. _ 0.18 __ 0.72 RECEPT. - SALES R 6.0 1 20 12 13 20 1 8.8 S STOREFRONT SIGN 1.00 ,._ 0.18 '' RECEPT. - CASHWRAP R 1.5 1 20 14 15 20 1 2.0 L1 LTG - BOH 0.22 0.18 RECEPT. • CASHWRAP R 1.5 1 20 16 _ 17 20 1 4.5 R RECEPT. - STOREFRONT _ '_- 0.54 f-- 0.72- RECEPT. - FURNITURE R 6.0 1 20 18 19 20 _ 1 .4 l L1 LTG - FITTING ROOM 0.05 �' 2.08 WATER HEATER WH 20.0 2 30 20 21 SPARE _ '' 2.08 _ WATER HEATER WH 20.0 2 30 22 23 _ SPARE -_ _ _ _ ^ - 0.10 VAV-1 0 0.8 1 20 24 25 SPARE �' �' ��/� SPARE 26 27 SPARE4KW-C;.__ SPARE 28 29SPARE -`SPARE 30 GROUND: SOLID DIVERSITY: 105% 4.8 KW -A 4.6 KW -B 4.0 SCCR: 42 kAIC BALANCE: 89% CONNECTED: 13.4 KW 37.5 AMPS SPEC. SECTION 262416 PF: 99% DEMAND: 14.1 KW 39.4 AMPS I i rF-, n-nCr%i uvv, U-UUULINU, NNIM 1 UNLAN KtJIJ I IV t, r M -KI I UHLN MU I UK, WH -WA I EK HLA ILK, OM -OTHER MOTOR, L1,L2 OR 1 -3 -LIGHTING, TL -TRACK LIGHTING, S -SIGNS, SW -SHOW WINDOW, R -RECEPTACLES, SF -SUB FEED, 0 -OTHER, E-EXISITNG SIZE: MLO -MAIN LUG ONLY, MOB -MAIN CIRCUIT BREAKER NOTE: GF -GROUND FAULT, AF -ARC FAULT, E -EXISTING TC -VIA TIME CLOCK, ST -SHUNT TRIP, LC -LUCK ON, PC -PHOTO CELL CONTROLLED OPTIONS: SFL-SUB FEED LUGS, FTL-FEED THRU LUGS (2) #1 A-24 ""-'"' LEDER (3) #6 & GND IN 1 "C BY E.C. U15C;(JININLU 15W1 I (AFI WITH 60A FUSES. ONE -LINE DIAGRAM EZ3�°wa S� CALL: N.T.S. - - NEW 60A, 3 -POLE DISCONNECT SWITCH WITH 60A FUSES. I I - LANDLORD'S EXISTING 480Y/277V, 3 -PH, 4W DISTRIBUTION PANEL GENERAL NOTE: A. CONTRACTOR SHALL VISIT THE SITE AND FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS UNDER WHICH HE IS TO PERFORM HIS WORK. NO ALLOWANCE WILL BE MADE FOR FAILURE TO COMPLY. PARTNERS B. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE 1993 (OR LATEST ADOPTED) NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. C. VERIFY EXACT LOCATION, MOUNTING HEIGHT AND ELECTRICAL REQUIREMENTS OF ALL brand : operations: build EQUIPMENT PROVIDED BY OTHERS (INCLUDING HVAC EQUIPMENT) PRIOR TO ROUGH -IN AND PROVIDE ALL REQUIRED FUSIBLE SWITCHES, TRANSFORMERS, STARTERS NECESSARY FOR PROPER OPERATION OF EQUIPMENT E. DUPLEX RECEPTACLES MOUNTED WITHIN 6FT. OF SINK TO BE A GFI RECEPTACLE. 7007 DISCOVERY BLVD F. ALL WIRING SHALL BE COPPER, THHN/THWN OR XHHW INSULATED IN CONDUIT. MINIMUM LIN, OH DUBOH43Q17 CONDUIT SIZE TO BE 1/2". PROVIDE INSULATED COPPER BOND WIRE ON ALL CIRCUITS. 614.634. T I!� A G. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF LIGHT FIXTURES. VERIFY ;I c�j CEILING TYPES AND PROVIDE NECESSARY MOUNTING HARDWARE TO ACCOMMODATE LIGHT WDPARTNER[S.COM FIXTURES USED. PROVIDE SLOPE CEILING ADAPTERS WHERE REQUIRED. f o I H. _ ADDITIONAL EXIT SIGNS AND EMERGENCY LIGHTING MAY BE REQUIRED. ADDITIONAL -A FIXTURES SHALL BE LOCATED AS DIRECTED BY THE LOCAL BUILDING AUTHORITY. LANDLORD REQUIREMENTS: • PRIOR TO BID, TENANT IS REQUIRED TO VERIFY THAT THE LANDLORD'S EXISTING AVAILABLE ELECTRICAL SERVICE MEETS THE TENANTS TOTAL CONNECTED LOAD. • TGC TO SURVEY ALL EXISTING ELECTRICAL EQUIPMENT AND VERIFY ANY ADDITIONAL LANDLORD WORK TO BE COMPLETED. VERIFY WITH MALL OPERATIONS. • COORDINATE ALL NEW ROUTING OF CONDUIT, FEEDER CABLES, AND CONNECTIONS TO LANDLORD'S MAIN ELECTRICAL GEAR WITH MALL OPERATIONS.. + ANY AND ALL UPGRADES TO EXISTING EQUIPMENT SHALL BE AT TGC AT TENANTS EXPENSE.