Loading...
1295 Red Cleveland Blvd - BC09-000874 (SANFORD AIRPORT AUTHORITY) (TERMINAL A - INTERNATIONAL DEPARTURES - UPPER LEVEL) (A)l"�jrl "I I , .. REVISION PERMIT # DATE_ CLQ PROJECT ADDRESS CIO-/ ��4 le- .-I a IlrIticl IV -0/1 -F nCONTRACTOR PHONE #. 'YL13-69cIV-130Z) FAX# 7 - 3,0 - 67a CONTACT PERSON en S, qLr- / C�,No UTILITY DEPT FIRE PREVENTION PLANNING BUILDING 6 0 .Hudson News udson Boo ellers Palw%yrus p RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEq P TERMINAL A- INTERNATIONAL - LEVEL 2 DIRECTORY y GENERAL 9 NOTES 1. ALL WORK IS TO CONFORM TO ALL AFFLICADLE NATIONAL, STATE AND LOCAL REPRESENTATIVE 12. ALL WOODOWORK SHALL DE MANUFACTURED IN ACCOKPANCE WITH THE CURRENT GENERAL SPECIFICATIONS CODES AND AUTHORITIES, WORK SHALL BE APPROVED AND MEET THE LANDLOKD'S ADDITIONAL WORK 15 REQUIRED AFTER STORE 15 TURNED OVER TO TENANT, THE EDITION OF THE ARCHITECTURAL WOODWORK QUALITY 5TANPAKD5 OF THE LANDLORD REQUIREMENTS, G.G. SHALL PROVIDE PROTECTION FOR ANY EXFOSED SURFACES, FIXTURING, AND ARCHITECTURAL WOOPWOKK INSTITUTE IN THE GRADES SHOWN ON DRAWING5. DEMOLITION BARRICADE AND TEMP FIXTURES 1200 RED CLEVELAND BLVD MERCHANDISE AND SHALL DE RESFON5I13LE FOR RETURNING STORE TO A "STORE SURFACES SHALL DE TRUE STRAIGHT AND FREE FROM ALL MACHINE AND TOOL 2. THE G.C. TO VERIFY ALL DIMENSIONS AT THE JOB 51TE AND REPORT ANY OPENING" CONDITION. MARKINGS, BRUISES, INDENTATIONS, CHIPS, AND APKASIONS. REFLECTED CEILING PLAN D15CKEPANCIE5 TO THE TENANT'S REPRESENTATIVE. THE G.C. 15 KESFON5IBLE INTERIOR ELEVATIONS PROJECT COORDINATOR > FOR THE PROPER FIT AND INSTALLATION OF ALL WORK SHOWN ON THESE a. THE G.C. SHALL V151T THE JOB SITE PRIOR TO DIPPING OR AWARD OF CONTRACT TO 15. THE G.G. SHALL TAKE ALL PRECAUTIONS TO MAINTAIN FREE ACCESS OF ALL STOREFRONT DETAILS DRAWINGS. THE ARCHITECT SHALL NOT BE KE5FON51DLE FOR ANY FADKICATION IN5FECT EXISTING FIELD CONDITIONS, TH15 CONTRACT SHALL INCLUDE ALL LABOR LANPLOKWTENANT SERVICE PERSONNEL AND THE FUDLIC THPOUG'H THE AREAS STOREFRONT DETAILS OR INSTALLATION TECHNIQUES PROVIDED DY THE G.G. OR ANY 5U[3-CONTKACTOKS. ARCHITECT INVOLVED AND 5HALL SEE THAT ALL LANDLOKWTENANT FACILITIES, EQUIPMENT; FIXTURE PLAN AND DETAILS " CONDITIONS. THE G.C. SHALL CONTACT THE ARCHITECT, ENGINEER, OR TENANT AND SERVICES ARE FULLY OFERADLE DUKING 5U51NE55 HOUK5. ANY SHUT DOWN 3. THE G.C. SHALL SECURE AND PAY FOR ALL PERMITS, FEES, LICEN5E5, TEMPORARY KEPKESENTATIVE FRIOK TO BIDDING FOR INTEKFKETATION5 AND CLARIFICATIONS OF ELECTRIC, TELEPHONE, COMMUNICATIONS, FLUMBING, OR HVAC SERVICES CASHWRAP UTILITIES, INSPECTIONS, TESTS, AND CARRY LIADILITY INSURANCE AS REQUIRED. ENGINEER REQUIRED SHALL BE SCHEDULED WITH THE LANDLORD/TENANT' KEFRE5ENTATIVE5 GONDOLA/ KEYCHAIN MAGNET DISPLAY INCLUDE SAME IN DID, CLAKIFICATION5 MADE BY THE ARCHITECT, ENGINEER, OR "TENANT'S AND ACCEPTED DY SAME PRIOR TO ANY INTEKUFTION OF SERVICE. 4. UNLE55 OTHERWISE NOTED, THE G.C. SHALT_ PROVIDE AND PAY ALL ALL LADOR, REPRESENTATIVE AFTER BIDDING WILL BE FINAL AND SHALL DE IMPLEMENTED AT 14. ALL'EXI5TING TO REMAIN' ITEMS'OR MATEKIAL5 SHALL DE FKOTECTED BOOK WALL UNIT MATERIALS, EQUIPMENT, TOOLS, CONSTRUCTION EQUIPMENT, MACHINERY, G.G.'5 COST, THROUGHOUT THE CONSTRUCTION PERIOD AND SHALL DE THOKOUGHL\( CLEANED > TKAN51"OKTATION,. INSPECTIONS OR TEST'S SPECIFIED OR REQUIRED DY THE PAPYRUS TABI E JUST PRIOR TO TURNOVER OF 5FACE TO TENANT. LOCAL/5TATE DUILDING DEPARTMENT, AND OTHER SERVICES AND FACILITIES 9. ALL ELECTRICAL AND TELEPHONE WIRING AND CONDUIT SHALL BE CONCEALED IN 22. IF REQUIRED DY THE LANDLORD OR LOCAL AUTHORITIE5, THE G.C. SHALL PROVIDE NECE55AKY FOR FKOFEK AND TIMELY EXECUTION OF WORK, WALLS, CEILINGS, OR MILLWORK. 15. THE G.0 AND ALL. 5UDCONTRACTOK5 MUST DISPLAY PROPER ISSUED SECURITY . IDENTIFICATION AT ALL TIMES AS REQUIRED DY THE LANDLORD. 5, ALL FIXTUKE5, EQUIPMENT, COMPONENTS AND MATEKIAL5 DELIVERED TO THE 51TE AUTHORITIES, DE MADE PART OF THE CONSTRUCTION DOCUMENTS. i AND RECEIVED DY THE CONTRACTOR AND/OK H15 AGENTS, BECOME THE 16. TI IE G.C. SHALL DE ROUND TO THE DUILDING PULES A5 TO THE HOURS OF WORK, KE5FON5113ILITY OF THE G.C. NO DELIVERIES WILL DE ACCEPTED BY THE USE OF THE ELEVATORS AND STAIRS, STORAGE AND REMOVAL OF DEDF:15, ET -C, LANDLORD, ALL WOKr 5HALL. DE PERFORMED A5 EXFEDITIOUSL`(A5 P0550LE. THE TAX. TR VEL DF "(ANCE ROVID ,Di 44'- " CONTRACT PRICE MIDST INCLUDE ANY AND ALL CONSIDERATION OF THE 6. NO 505TITUTIONS ARE ALLOWED WITHOUT PRIOR WRITTEN AFFKOVAL OF THE DUILDINGRULES. NO EXTRA CHARGES WILL DE ADDED AFTER CONTRACT 51GNING. TENANT. 17, ALL 1305 ARE TO BE SUDMITTED TO THE TENAT REPRESENTATIVE PER 1-115 V. THE G.C. SHALL KEEP THE JOB SITE CLEAN AT ALL "TIMES AND SHALL FKEVENT INSTRUCTIONS, 1305 SHALL BE BROKEN DOWN PEK THE TENANT DUST/DIRT FROM GETTING INTO THE AIRPORT COMMON AREA. UPON COMPLETION KEFRE5ENTATIVE'S DID FORM. OF WORK, THE G.C. SHALL THOROUGHLY CLEAN ENTIRE STORE. CLEAN ALL GLASS, WALL5, FIXTURING, FLOORS, AND CEILING. REMOVE ALL SCRATCHES & MARKS LEFT 15, CONSULTANTS' DRAWINGS AKE SUPPLEMENTAL TO THE ARCHITECTURAL DIRECTORY TENANT Hudson Group TENANT RAY BOWEN REPRESENTATIVE 1 MEADOWLANDS PLAZA SUITE902 GENERAL SPECIFICATIONS EAST RUTHERFORD, NJ 07073 ADDITIONAL WORK 15 REQUIRED AFTER STORE 15 TURNED OVER TO TENANT, THE TEL (404)822-7348 LANDLORD SANFURD ORLANDO INTERNATIONAL AIRPORT G.G. SHALL PROVIDE PROTECTION FOR ANY EXFOSED SURFACES, FIXTURING, AND SANFOF�D AIRPORT AUTHORITY DEMOLITION BARRICADE AND TEMP FIXTURES 1200 RED CLEVELAND BLVD MERCHANDISE AND SHALL DE RESFON5I13LE FOR RETURNING STORE TO A "STORE SANFORD,FL 32773 >1 LARRY A. DALE OPENING" CONDITION. PRESIDENT & C.E.O. REFLECTED CEILING PLAN CONTACT: JENNIFER TAYLOR INTERIOR ELEVATIONS PROJECT COORDINATOR > 407-585-4000 a. THE G.C. SHALL V151T THE JOB SITE PRIOR TO DIPPING OR AWARD OF CONTRACT TO TSI AIRPORT MANAGEMENT, INC. STOREFRONT DETAILS CONTACT: DAVE LOGAN IN5FECT EXISTING FIELD CONDITIONS, TH15 CONTRACT SHALL INCLUDE ALL LABOR DIRECTOR OF OPERATIONS STOREFRONT DETAILS 407-585-4536 ARCHITECT METALUNA ARCHITECTURE FIXTURE PLAN AND DETAILS & DESIGN, P.C. CONDITIONS. THE G.C. SHALL CONTACT THE ARCHITECT, ENGINEER, OR TENANT 1665 HIGHWAY 588 COOLER ENCLOSURE ELLISVILLE, MS 39437 KEPKESENTATIVE FRIOK TO BIDDING FOR INTEKFKETATION5 AND CLARIFICATIONS CON TACT: SCOTT POWELL CASHWRAP CELL (001)433-3830 ENGINEER DON PENN, CONSULTING ENG. GONDOLA/ KEYCHAIN MAGNET DISPLAY 635 WESTPORT PARKWAY # 300 CLAKIFICATION5 MADE BY THE ARCHITECT, ENGINEER, OR "TENANT'S GRAPEVINE, TX 76051 > CONTACT: JACK PAMPALON REPRESENTATIVE AFTER BIDDING WILL BE FINAL AND SHALL DE IMPLEMENTED AT CELL PHONE: (404) 210-4699 FROM CONSTKU(,TION, FLOURS SHALL DE IvIOPFED. 5TEP5 SHALL DE TAKEN TO REMOVE FROM ALL EXPOSED SUKFACE5 AND FIXTURING: DUST, DEDRIS, PAINT DKAWINGJ. II I� THE RE�PONSIDILI" UF I1•iE G.G. 1U CKUSS H[ -GK. 7V1I1I TrE ARCHITECTURAL DRAWINGS PRIOR TO THE ORDEKING/INSTALLATION OF ANY T-1.1 SPECIFICATIONS APPLICABLE CODES DRIPPINGS, OIL, GREASE, ADHESIVES, AND OTHER DLEM15HE5. IN THE EVENT THAT MECHANICAL, P_LUMDING, AND ELECTRICAL WORK. ANY P15CREFANCIE5 DETWEEN GENERAL SPECIFICATIONS BUILDING FLORIDA BUILDING CODE, 2004 EDITION WITH ALL SUPPLEMENTS ADDITIONAL WORK 15 REQUIRED AFTER STORE 15 TURNED OVER TO TENANT, THE THE ARCHITECTURAL AND THE CONSULTING ENGINEEK'5 DRAWINGS 1,5HALL DE GENERAL SPECIFICATIONS FIRE FLORIDA FIRE PREVENTION CODE, 2004 EDITION G.G. SHALL PROVIDE PROTECTION FOR ANY EXFOSED SURFACES, FIXTURING, AND DROUGHT TO THE ARCHITEC T'5 ATTENTION FOK IMMEDIATE CLARIFICATION. DEMOLITION BARRICADE AND TEMP FIXTURES ELECTRICAL NATIONAL ELECTRICAL CODE, 2002 EDITION WITH ALL SUPPLEMENTS MERCHANDISE AND SHALL DE RESFON5I13LE FOR RETURNING STORE TO A "STORE A-1.0 >1 MECHANICAL FLORIDA BUILDING CODE, 2004 EDITION MECHANICAL OPENING" CONDITION. 19, ALL EXIT5'SHALL DE KEPT READILY ACCE55IDLE AND UNO55TKUCTED AT ALL REFLECTED CEILING PLAN WITH ALL SUPPLEMENTS, CHAPTER 13, ENERGY EFFICIENCY INTERIOR ELEVATIONS TIMES. > PLUMBING FLORIDA BUILDING CODE, 2004 EDITION, PLUMBING W/SUPPLEMENTS a. THE G.C. SHALL V151T THE JOB SITE PRIOR TO DIPPING OR AWARD OF CONTRACT TO A-3.0 STOREFRONT DETAILS ACCESSIBILITY FLORIDA BUILDING CODE, 2004 EDITION, CHAPTER ll, ACCESSIBILITY CODE IN5FECT EXISTING FIELD CONDITIONS, TH15 CONTRACT SHALL INCLUDE ALL LABOR 20. DAMAGED,5UKFACE5 AND ANY OTHER DEFECTS CAUSING AN" APPEARANCE STOREFRONT DETAILS BASF BUILDING AND MATERIALS NECESSARY FOR FIELD MODIFICATIONS DUE TO EXISTING DIFFERENT FROM A NEW, FIK5"F CLASS, FINISHED INSTALLATION SHALL EITHER DE FIXTURE PLAN AND DETAILS USE GROUP CLASSIFICATION Al -ASSEMBLY CONDITIONS. THE G.C. SHALL CONTACT THE ARCHITECT, ENGINEER, OR TENANT REPAIRED OR. THE G.C. SHALL REMOVE EX15"TING AND IN5TAL'L NEW SURFACES AT COOLER ENCLOSURE TYPE IN HEIGHT iNSON TYPE II B, SPRINKLERED BUILDING HEIGHT IN S"FURIES 2 KEPKESENTATIVE FRIOK TO BIDDING FOR INTEKFKETATION5 AND CLARIFICATIONS NO ADDITIONAL C05 T. CASHWRAP CODE ANALYSIS. OF THE DESIGN AND INCLUDE IN HIS DID ALL COSTS TO MEET THE DESIGN INTENT. F-2.5 GONDOLA/ KEYCHAIN MAGNET DISPLAY OCCUPANCYGROUP: M CLAKIFICATION5 MADE BY THE ARCHITECT, ENGINEER, OR "TENANT'S 21. PROVIDE FIRE EXTINGUISHEK(5) HAVING A MINIMUM RATING OF 2 -A.10 -B.0 FOR > SPRINKLED: YES REPRESENTATIVE AFTER BIDDING WILL BE FINAL AND SHALL DE IMPLEMENTED AT EVERY 2,500 SF OF FLOOR AREA. TRAVEL DISTANCE TO'ANY EXTINGUI5HEK SHALL BOOK WALL UNIT STOREAREA: '1430 SFTOTAL G.G.'5 COST, NUT EXCEED 75'. LOCATE EX"FINGU15HEK DETWEEN 4" AFF AND 60" AF"F", > TOTAL OCCUPANTLOAD: A, PAPYRUS TABI E 1880 S.F. +60 S.F. PER OCCUPANT = 32 OCCUPANTS 9. ALL ELECTRICAL AND TELEPHONE WIRING AND CONDUIT SHALL BE CONCEALED IN 22. IF REQUIRED DY THE LANDLORD OR LOCAL AUTHORITIE5, THE G.C. SHALL PROVIDE EGRESS REQUIRED: WALLS, CEILINGS, OR MILLWORK. SPRINKLER PLANS FKEFAKED DYA LANDLORD-APPKOVED FLORIDA STATE 32 OCCUPANTS,1.15"PER OCCUPAN'I-=36"MIN, REQUID PER E LICENSED CONTRACTOR, AND IF REQUIRED 13Y THE LANDLORD OR LOCAL (1) EXITS REQUIRED AUTHORITIES, DE MADE PART OF THE CONSTRUCTION DOCUMENTS. EGRESS PROVIDED: (1) STOREFRONT EXffS TAX. TR VEL DF "(ANCE ROVID ,Di 44'- " PHIS DRAWING AS AN INSTRUMENT )F SERVICE, IS AND SHALL REMAIN FHE PROPERTY OF ARCHITECT. JSE OF THE DRAB/VING, OR ANY ZEPRObUCTION THERE OF, WITHOUT FHE EXPRESS WRITTEN PERMISSION 7F THE DESIGNER IS STRICTLY 'ROHIBITED. SUBMISSION OR )ISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR -OR ANY OTHER PURPOSES IN DONJUNCTION WITH THIS PROJECT IS iOT.TO BE CONSTRUED AS "LIBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS, COPYRIGHT 2008 runumb�ert wall fikXSL4RMIP1lIPPIL'� 1f�1+nIPPMnPilili ■RSI T-1.0 TITLE SHEET T-1.1 SPECIFICATIONS T-1.2 SPECIFICATIONS G-1.0 GENERAL SPECIFICATIONS G-1.1 GENERAL SPECIFICATIONS G-1.2 GENERAL SPECIFICATIONS D-1.0 DEMOLITION AND REMOVALS D-1.1 DEMOLITION BARRICADE AND TEMP FIXTURES LS -1.0 LIFE SAFETY PLAN A-1.0 CONSTRUCTION PLAN A-1.1 FLOORING MATERIAL PLAN A-1.2 REFLECTED CEILING PLAN A-2.0 INTERIOR ELEVATIONS A-2.1 INTERIOR ELEVATIONS,SIGNS & FINISH SCHEDULE A-2.2 STOREFRONT ELEVATION A-3.0 STOREFRONT DETAILS A-3.1 STOREFRONT DETAILS A-3.2 STOREFRONT DETAILS A-4.0 DETAILS F-1.0 FIXTURE PLAN AND DETAILS F-2.0 SLATWALL DISPLAY UNIT F-2.1 COOLER ENCLOSURE F-2.2 NEWSTOWER F-2.3 CASHWRAP F-2.4 CASHWRAP DETAILS F-2.5 GONDOLA/ KEYCHAIN MAGNET DISPLAY F-2.6 NESTED TABLES F-3.0 SOUVENIRS / GIFTS WALL UNIT F-3.1 ELECTRICAL PANEL ENCLOSURE / WALL UNIT F-4.0 BOOK WALL UNIT F-4.1 BOOK TABLE F-4.2 PAPYRUS WALL UNITS F-4.3 PAPYRUS TABI E E-1.1 LIGHTING PLAN E-1.2 POWER PLAN E-1.3 FIRE ALARM PLAN E-1.4 PANEL, SPECS AND RISER DIAGRAM M-1.1 ) MECHANICAL PLAN AND SPECIFICATIONS 02060 REMOVALS_: I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CON"T"RACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION I GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. , 2. SEE ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR SPECIFIC REMOVALS (DEMOLITION) AND REQUIREMEN"T"S. 3. GENERAL REMOVALS AND RELOCATIONS: 1. REMOVE ALL ITEMS, MATERIALS AND FINISHES REQUIRED FOR THE INSTALLATION OF THE NEW WORK, AND/OR THE RELOCATION OF EXISTING, AS DESCRIBED IN PERTINENT SECTIONS OF THESE SPECIFICATIONS AND/OR SHOWN ON THE DRAWINGS INCLUDING BUT NOT LIMITED TO: WALL AND FLOOR SURFACE MATERIALS FOR THE PROPER ATTACHMENT AND/OR APPLICATION OF NEW FINISHES AND ALL EXISTING MISCELLANEOUS MECHANICAL AND ELECTRICAL ITEMS, DEVICES AND FIXTURES: SEE MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS. 2. REMOVE ALL MISCELLANEOUS INCIDENTAL MATERIALS AND ITEMS IN CONFLICT WITH THE PROPER PREPARATION, INSTALLATION AND FINISHING OF THE NEW WORK. 3. REMOVE ALL EXISTING DAMAGED AND MARRED FINISH MATERIALS AND REPLACE WITH NEW TO MATCH EXISTING. 4. ITEMS NOTED TO BE REMOVED SHALL BE REMOVED IN THEIR ENTIRETY, INCLUDING ALL INSTALLATION FASTENINGS, UNLESS OTHERWISE NOTED. ALL ABUTTING MATERIALS AND FINISHES SHALL BE PATCHED TO MATCH FOR NO NOTICEABLE REMOVAL INDICATIONS PER SECTION 01045. 5. REPAIR AND PATCH TO MATCH EXISTING WHERE LEFT EXPOSED TO VIEW OR DAMAGED BY REMOVALS: SEE SECTION 01045. II MATERIALS - (NA) III EXECUTION - 1. ALL REMOVALS SHALL BE IN COMPLIANCE WITH ALL LOCAL, STATE ADOPTED CODES, BUILDING OWNER REQUIREMENTS, AND ALL APPLICABLE FEDERAL SAFETY REGULATIONS. ALL NEW INTERIOR FINISH MATERIALS MUST BE INSTALLED ON NON-COMBUSTIBLE SURFACES. WHERE NEW FINISH MATERIALS ARE TO BE INSTALLED ON EXISTING SURFACES ALL EXISTING FINISH MATERIALS, INCLUDING GLUE, BONDING AGENTS, ETC., MUST BE REMOVED PRIOR TO INSTALLATION OF ANY NEW MATERIAL. 2. IF ASBESTOS OR ANY OTHER HAZARDOUS MATERIALS ARE ENCOUNTERED, NOTIFY OWNER IN WRITING PRIOR TO PROCEEDING. STATE GOVERNING AUTHORITY'S APPROVED METHODS OF PROPER REMOVAL AND DISPOSAL PROCEDURES. UPON WRITTEN NOTICE FROM OWNER TO PROCEED THESE METHODS AND PROCEDURES ARE TO BE STRICTLY FOLLOWED. 3. ALL MATERIALS AND ITEMS THAT ARE TO BE REUSED AND RELOCATED IN CONJUNCTION WITH THE NEW WORK SHALL BE CAREFULLY CUT AWAY FROM THE EXISTING ABUTTING WORK TRUE TO LINE AT THE NEAREST JOINT, SURFACE BREAK OR PATTERN LINE TO ENSURE NO NOTICEABLE DIFFERENCE BETWEEN NEW AND EXISTING TO REMAIN. REMOVALS SHALL BE KEPT TO A MINIMUM. MATERIALS TO BE REUSED AND RELOCATED SHALL BE PROPERLY HANDLED, TAGGED AND STORED TO PREVENT DAMAGING AND BREAKING. 4. CAREFULLY COORDINATE ALL TRADES TO ENSURE PROPER AND ADEQUATE INTERFACE OF THE WORK. 5. WHEN WORK IS STOPPED, PROVIDE AND MAINTAIN IN PLACE SUITABLE COVERINGS AND BARRIERS FOR PROTECTION OF THE WORK AND SAFETY FOR ALL PERSONNEL AND BUILDING USERS. 6. PROTECT ALL WORK, EXISTING AND NEW, FROM DAMAGE BY ANY CAUSE THROUGHOUT THE DEMOLITION OPERATIONS. PROTECTIVE COVERINGS OR BARRIERS SHALL NOT MAR, STAIN OR PENETRATE THE FINISHED WORK. 7. COORDINATION OF THE WORK: I. COORDINATE ANY ALL MECHANICAL AND ELECTRICAL WORK FOR THE PROPER DISCONNECTIONS; PROTECTIONS AND CAPPINGS: SEE MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS. 2. IF APPLICABLE, COORDINATE ALL STRUCTURAL WORK FOR THE PROPER PHASING, STAGING AND SEQUENCE OF REMOVAL REQUIREMENTS: SEE STRUCTURAL DRAWINGS AND SPECIFICATIONS. 8. UNDERTAKE WHATEVER PRECAUTIONS ARE NECESSARY TO CONTROL AND PREVENT EXCESSIVE DUST DURING REMOVALS. DO NOT ALLOW DUST BEYOND THE CONTRACT LIMIT LINE. 9. REMOVE ALL PORTIONS OF THE WORK IN A SAFE MANNER WITH CARE TO PREVENT DAMAGE TO ADJACENT AND REMAINING STRUCTURE, FINISHES OR ANY OTHER ITEMS OF THE TENANTS PROPERTY OR OTHER TENANT AREAS AND PUBLIC SPACES. Q3500 CEMENTITIOUS UNO-ERL-AYMENT-: 05500 MISCELLANEOUS METALS: I WORK INCLUDED - I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAI" OF ALL OTHER TRADES AFFECTING, OR AFFECTED 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL: 2. PROVIDE AND INSTALL: I. ALL FLASH PATCHING REQUIRED FOR THE PROPER INSTALLATION OF ALL FINISH 1. ALL MISCELLANEOUS METAL, INCLUDING BUT NOT LIMITED TO, STRUCTURAL FLOORING SECTIONS OF THESE SPECIFICATIONS. SUPPORT STEEL AND SUPPORT STEELFOR OVERHEAD OR SIDEFOLDING GRILLE AS SHOWN ON THE DRAWINGS, AND ALL FASTENERS AND ANCHORAGE DEVICES FOR THE 2. ALL FLOOR LEVELING REQUIRED FOR FLOOR ELEVATIONS SHOWN. INSTALLATION OF WORK FOR THIS AND ALL SECTIONS OF THESE SPECIFICATIONS INCLUDING (MECHANICAL AND) ELECTRICAL WORK. 3. FILL ALL EXISTING UNUSED AND ABANDONED FLOOR PENETRATIONS. 3. PROVIDE COORDINATED SHOP DRAWINGS AND PRODUCT LITERATURE 3. PROVIDE MANUFACTURER'S PRODUCT DATA LITERATURE IN ON ALL ITEMS AND SAMPLES OF ALL FINISHES IN ACCORDANCE WITH SECTION 01300 OF ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. THESE SPECIFICATIONS. 4. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH 4. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 01710 OF MANUFACTURER'S WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS AND STAIN REMOVAL METHODS. I. QUALIFIED EXPERIENCED INSTALLER (APPLICATOR) OF MATERIAL SPECIFIED, ACCEPTABL E TO "THE MANUFACTURER, WHO HAS A SUCCESSFUL RECORD OF 5. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH AISC, COMPLETING CEMENT -BASED UNDERLAYMENT APPLICATIONS SIMILAR IN MATERIAL ASTM, MFMA, NAAMM, AWS, SSPC STANDARDS AND APPLICABLE CODE REQUIREMENTS. AND EXTENT TO THAT REQUIRED FOR THIS PROJECT II MATERIALS - II MATERIALS - 1. ALL MISCELLANEOUS SUPPORT STEEL AND CLOSURE ITEM MATERIAL, I. UNDERLAYMENT: CEMENT BASED POLYMER -MODIFIED, FABRICATION AND ERECTION SHALL COMPLY WITH THE REQUIREMENTS OF THE AISC SELF -LEVELING, FILL, PATCHING AND RESURFACING COMPOUND CAPABLE OF STANDARD SPECIFICATIONS FOR STRUCTURAL STEEL, WITH SUPPLEMENTS TO DATE. FEATHEREDGE TO SIX INCH THICKNESS AS MANUFACTURED BY: ARDEX, INC., K-15 SELF -LEVELING UNDERLAYMENT CONCRETE; CONSPEC MARKETING AND 1. IN FABRICATION OF ITEMS WHICH WILL BE EXPOSED TO VIEW, LIMIT MATERIALS TO MANUFACTURING CO., INC., CONFLOW; L&M CONSTRUCTION CHEMICALS, INC., LEVELEX THOSE WHICH ARE FREE FROM SURFACE BLEMISHES, PITTING, ROLLED TRADE NAMES, UNDERLAYMENT, OR ARCHITECT ACCEPTED EQUAL. AND ROUGHNESS. 1. CEMENT BINDER: ASTM Com' 150, PORTLAND CEMENT, OR HYDRAULIC BLENDED 2. COMPLY WITH FOLLOWING STANDARDS, AS PERTINENT: CEMENT AS DEFINED BY ASTM C 219. COMPRESSIVE STRENGTH NOT LESS THAN 4100 PSI (28 MPA) AT 28 DAYS WHEN TESTED ACCORDING TO ASTM C 109/C 109M. 1. STEEL PLATES, SHAPES, AND BARS: ASTM A36 2. STEEL PLATES TO BE BENT OR COLD -FORMED: ASTM A283 2. UNDERLAYMENT ADDITIVE: RESILIENT -EMULSION PRODUCT OF UNDERLAYMENT MANUFACTURER FORMULATED FOR USE WITH UNDERLAYMENT WHEN APPLIED TO SUBSTRATE AND CONDITIONS INDICATED. 2. AGGREGATE: WELL -GRADED, WASHED GRAVEL, 1/8 TO 1/4 INCH, OR COARSE SAND AS RECOMMENDED BY UNDERLAYMENT MANUFACTURER. I. PROVIDE AGGREGATE WHEN RECOMMENDED IN WRITING BY UNDERLAYMENT MANUFACTURER FOR UNDERLAYMENT THICKNESS REQUIRED. 2. WATER: POTABLE AND AT A "TEMPERATURE NOT MORE THAN 70 DEG. F. 3. PRIMER: PRODUCT OF UNDERLAYMENT MANUFACTURER, RECOMMENDED IN WRITING, FOR SUBSTRATE CONDITIONS AND APPLICATIONS INDICATED. III EXECUTION - 1. EXAMINE SUBSTRATES, WITH INSTALLER PRESENT, FOR CONDITIONS AFFECTING PERFORMANCE OF UNDERLAYMENT INCLUDING SUBSTRATE MOISTURE CONTENT. BEGIN UNDERLAYMENT APPLICATION ONLY AFTER UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 2. PROPERLY PREPARE AND CLEAN SUBSTRATE, IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SUBSTRATE INDICATED PRIOR TO APPLICATION. PROVIDE CLEAN, DRY, NEUTRAL -PH SUBSTRATE FOR UNDERLAYMENT APPLICATION. 1. TREAT NON-MOVING SUBSTRATE CRACKS TO PREVENT CRACKS FROM TELEGRAPHING (REFLECTING) THROUGH UNDERLAYMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN RECOMMENDATIONS. 2. FILL SUBSTRATE VOIDS TO PREVENT UNDERLAYMENT FROM LEAKING. 3. MECHANICALLY REMOVE LAITANCE, GLAZE, EFFLORESCENCE, CURING COMPOUNDS, FORM -RELEASE AGENTS, DUST, DIRT, GREASE, OIL, AND OTHER CONTAMINANTS THAT MIGHT IMPAIR UNDERLAYMENT BOND ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. 4. AFTER SUBSTRATE PREPARATION, TEST SUBSTRATE FOR ADHESION WITH UNDERLAYMENT ACCORDING TO MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. MIX, APPLY AND CURE UNDERLAYMENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 1. COORDINATE APPLICATION OF COMPONENTS TO PROVIDE OPTIMUM UNDERLAYMENT-To-SUBSTRATE AND INTERCOAT ADHESION. 2. APPLY UNDERLAYMENT TO PRODUCE UNIFORM, LEVEL SURFACE, APPLY FINAL LAYER WITHOUT AGGREGATE TO PRODUCE A SMOOTH SURFACE. FEATHER EDGES TO MATCH ADJACENT FLOORING. 10. ALL MATERIALS UNLESS NOTED TO BE REUSED OR TO BE SALVAGED SHALL BE REMOVED OFF THE PROPERTY TO AN AVAILABLE DUMP OR SITE OF THE CONTRACTOR'S OWN CHOOSING AND ARE TO BE PROPERLY AND RESPONSIBLY DISPOSED OF. 3. STEEL TUBING (HOT -FORMED, WELDED, OR SEAMLESS): ASTM A501 4. STEEL BARS AND BAR -SIZE SHAPES: ASTM A306, GRADE 65. OR ASTM A36 5. COLD -FINISHED STEEL BARS: ASTM A108 6. COLD -ROLLED CARBON STEEL SHEETS: ASTM A336 7. GALVANIZED CARBON STEEL SHEETS: ASTM A526, WITH G90 ZINC COATING IN ACCORDANCE WITH ASTM A525 8. GRAY IRON CASTINGS: ASTM A48, CLASS 10 9. MALLEABLE IRON CASTINGS: ASTM A47 10. STEEL PIPE: ASTM A53 GRADE A, SCHEDULE 40, BLACK FINISH UNLESS OTHERWISE NOTED 11. CONCRETE INSERTS: 1. THREADED OR WEDGE TYPE GALVANIZED FERROUS CASTINGS OF MALLEABLE IRON COMPLYING WITH ASTM A27 2. PROVIDE REQUIRED BOLTS, SHIMS, AND WASHERS, HOT -DIP GALVANIZED IN ACCORDANCE WITH ASTM A153. 3. ALL STEEL SHALL BE SHOP PRIME FINISHED FOR CONCEALED ITEMS AND SCHEDULED FINISH FOR EXPOSED TO VIEW ITEMS. 1. PRIMER: USE "10-99 TNEMEC PRIMER" OR "RUSTOLEUM NUMBER 5769 PRIMER" 2. FOR REPAIR OF GALVANIZING, USE A HIGH ZINC -DUST CONTENT PAINT COMPLYING WITH MIL -21035. 4. THE CONTRACTOR SHALL FURNISH MILL TEST REPORTS FROM THE PRODUCER OF THE STEEL CERTIFYING THAT THE STEEL MEETS THE MINIMUM REQUIREMENTS AS DEFINED BY ASTM SPECIFICATIONS. 5. LOOSE LINTELS SHALL BE INSTALLED OVERALL OPENINGS IN MASONRY WALLS AS LISTED BELOW EXCEPT WHERE OTHERWISE DETAILED ON THE DRAWINGS: OPENING LINTEL NOTE 4'-0" OR LESS 4" X 3 1/2" X 5/16 3 1/2" LEGS ARE HORIZONTAL 2. ALL WELDING SHALL BE IN ACCORDANCE WITH THE STANDARD CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION OF THE AMERICAN WELDING SOCIETY. WELDING ELECTRODES SHALL CONFORM TO ASTM SPECIFICATIONS E-70XX. ALL BUTT WELDS SHALL BE 1005 PENETRATION WELDS AND FILLET WELDS SHALL BE A MINIMUM 3/16". 3. ALL FASTENERS, THREADED AND DRIVEN, SHALL BE THE BEST OF THEIR RESPECTIVE TYPE, GRADE AND CLASS AND SHALL BE USED IN SUFFICIENT NUMBERS AND CORRECT SIZES FOR THE PARTICULAR APPLICATIONS. ALL FASTENERS SHALL BE HIDDEN IN THE FINISHED WORK. FASTENERS FOR EXTERIOR USE AND WHERE BUILT INTO EXTERIOR WALLS SHALL BE ZINC COATED FASTENERS. 4. ALL OTHER MISCELLANEOUS INCIDENTAL ITEMS AND MATERIALS IN TYPES SHOWN OR NOTED INCLUDING BUT NOT LIMITED TO; FASTENERS, ATTACHMENTS AND GROUT SHOWN, NOTED AND/OR REQUIRED FOR FULL COMPLETION OF THE WORK, SHALL BE OF QUALITY COMPARABLE AND COMPATIBLE TO MATERIALS SPECIFIED. 4. FIELD QUALITY CONTROL: III EXECUTION - 11. VERIFY SALVAGE REQUIREMENTS FOR ALL MATERIALS NOTED TO BE REMOVED WITH THE AIRPORT AND TENANT REPRESENTATIVE. MATERIALS NOTED TO BE 1. SLUMP TEST: IF SLUMP TEST IS RECOMMENDED IN WRITING BY 1. INSTALL ALL ITEMS IN ACCORDANCE WITH ACCEPTED SHOP DRAWINGS SALVAGED SHALL BE STORED PER INSERT BUILDING OWNER OR AUTHORITY AND THE MANUFACTURER, TEST UNDERLAYMENT FOR SLUMP AS IT IS PLACED FOR COMPLIANCE AND MANUFACTURER'S WRITTEN INSTRUCTIONS. PLUMB, LEVEL AND TRUE WITHOUT TENANT DIRECTIONS. WITH MANUFACTURER'S WRI"T"TEN RECOMMENDATIONS. DISTORTION, ALIGNED AND FITTED PROPERLY. COORDINATE WITH ALL BUILT-IN ITEMS OF OTHER SECTIONS OF THESE SPECIFICATIONS FOR CUTOUT LOCATIONS AND SIZE, 12. ALL REMOVALS SHALL LEAVE "THE EXISTING SURFACES AND SUBSTRATES FREE AND 2. FIELD SAMPLES: TAKE AT LEAST THREE MOLDED -CUBE SAMPLES SUPPORT AND ATTACHMENT REQUIREMENTS. CLEAN FOR THE PROPER PATCHING AND PREPARATION REQUIRED FOR THE SPECIFIED FROM EACH UNDERLAYMENT BATCH. TEST SAMPLES ACCORDING TO ASTM C 109/C NEW MATERIALS AND FINISHES. 109M FOR COMPLIANCE WITH COMPRESSIVE -STRENGTH REQUIREMENTS. 2. PROPERLY PROTECT ALL FINISH SURFACES UNTIL INSTALLATION COMPLETION AND JUST PRIOR TO ARCHITECT'S FINAL ACCEPTANCE. 13. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 5. DO NOT INSTALL (APPLY) FINISH FLOORING OVER UNDERLAYMENT 0'1710 OF "THESE SPECIFICATIONS. UNTIL AFTER TIME PERIOD RECOMMENDED BY UNDERLAYMENT MANUFACTURER. 3. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 02060 6. REMOVE AND REPLACE UNDERLAYMENT AREAS THAT EVIDENCE LACK OF BOND WITH SUBSTRATE, INCLUDING AREAS THAT EMIT A "HOLLOW" SOUND WHEN END OF SECTION 05500 TAPPED. 7. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 03500 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 061 QO CARPENTRY: WORK INCLUDED - 1. RELATED DOCUMENTS I. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 'r#Tii � : �[71►E9rGL� 1. ALL ROUGH CARPENTRY INCLUDING BUT NOT LIMITED TO, WOOD BLOCKING, SUPPORT GROUNDS, FURRING, BACKBOARDS, ANCHORS AND ROUGH HARDWARE AND OTHER INCIDENTAL ROUGH CARPENTRY WORK AS REQUIRED FOR WORK OF ALL SECTIONS OF THESE SPECIFICATIONS INCLUDING STRUCTURAL, MECHANICAL AND ELECTRICAL WORK: SEE DRAWINGS. 2. MISCELLANEOUS CUTTING AND PATCHING FOR ALL SECTIONS OF THESE SPECIFICATIONS INCLUDING MECHANICAL AND ELECTRICAL WORK: SEE SECTION 01045. 3. FIRESTOPPING AT ALL FLOOR AND WALL PENETRATIONS. PROVIDE UL FIRE RESISTANCE DIRECTORY DETAIL FOR EACH DIFFERENT INSTALLATION PROVIDED. 4. ALL TEMPORARY CONSTRUCTION REQUIREMENTS, INCLUDING BUT NOT LIMITED "TO TEMPORARY CONSTRUCTION PARTITIONS, SCAFFOLDING, SCREENS, BARRIERS AND SUPPORTS FOR REMOVALS, RE -INSTALLATIONS AND NEW WORK, INCLUDING STRUCTURAL, MECHANICAL AND ELECTRICAL WORK, IN COORDINATION WITH REQUIRED PHASING OF THE PROJECT. 5. ALL WOOD SHALL BE FIRE RETARDANT TREATED. 6. RODENT INFESTATION PREVENTION AT FLOOR AND WALL PENETRATIONS. WHEN REQUIRED BY HEALTH CODE FOR FOOD SERVICE AREAS. 3. PROVIDE COORDINATED SHOP DRAWINGS AND `'AMPLES OF ITEMS AS MAY BE REQUESTED BY THE ARCHITECT. 1. UPON COMPLETION OF THIS PORTION OF THE WORK, COMPLETE AND POST CERTIFICATES OF COMPLIANCE IN ACCORDANCE WITH PERTINENT REQUIREMENTS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION. 4. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH ALSO, APA, AWPA, NHLA, PSI, PS 20 AND APPLICABLE CODE REQUIREMENTS. "TREAT ALL LUMBER AND WOOD WITH FIRE RETARDANT AS REQUIRED FOR TYPE, USE AND CODE. 1. IN ADDITION TO COMPLYING WITH PERTINENT CODES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, UNLESS OTHERWISE SPECIFICALLY DIRECTED OR PERMITTED BY THE ARCHITECT COMPLY WITH: 1. "PRODUCT USE MANUAL" OF THE WESTERN WOOD PRODUCTS ASSOCIATION FOR SELECTION AND IJSE OF PRODUCTS INCLUDED IN THAT MANUAL; 2. "PLYWOOD SPECIFICATION AND GRADE GUIDE" OF THE AMERICAN PLYWOOD ASSOCIATION. MATERIALS - 1. ALL ROUGH CARPENTRY LUMBER SHALL BE CONSTRUCTION GRADE SEASONED, S4S DOUGLAS FIR OR WESTERN LARCH, SEASONED TO 10% OR LESS MOISTURE CONTENT. EACH PIECE SHALL BE GRADE STAMPED WITH OFFICIAL MARK OF RESPONSIBLE GRADING RULES ASSOCIATION. HIDDEN AND EXPOSED PLYWOOD, DFPA, INTERIOR AND EXTERIOR C -C GRADE MANUFACTURED IN ACCORDANCE WITH APA AND PS 1-66 STANDARDS. EACH PIECE SHALL BE GRADE STAMPED. 2. THREADED AND DRIVEN FASTENERS SHALL BE HOT -DIPPED GALVANIZED AFTER FABRICATION AND THE BEST OF THEIR RESPECTIVE TYPE, GRADE AND CLASS, AND SHALL BE USED IN SUFFICIENT NUMBER AND CORRECT SIZES FOR THE PARTICULAR APPLICATION. 3. ALL WOOD AND WOOD PRODUCTS SHALL BE FIRE RETARDANT TREATED IN COMPLIANCE WITH THE LOCAL AND STATE BUILDING CODES: PRESSURE TREATED WITH FIRE RETARDANT CHEMICALS, AND GRADE STAMPED, IN ACCORDANCE WITH REFERENCE STANDARDS CITED. 1. LUMBER AWPA C20-1988 2. PLYWOOD AW PAC27-1988 4. FIRESTOPPING 1. 3M FIRE PROTECTION PRODUCTS, OR ARCHITECT ACCEPTED EQUAL FIRESTOPPING AND SMOKE -STOPPING SYSTEMS AND DEVICES, AS LISTED IN THE UL FIRE RESISTANCE DIRECTORY FOR EACH RATED WALL AND FLOOR PENETRATION CONDITION. 5. ALL TEMPORARY CONSTRUCTION PARTITIONS, SCAFFOLDING, SCREEN, BARRIER AND SUPPORT TYPES, MATERIALS, FINISHES AND THEIR LOCATIONS SHALL BE IN ACCORDANCE WITH THE BUILDING OWNER'S TENANT CONSTRUCTION REQUIREMENTS AND ARE TO BE REVIEWED AND COORDINATED WITH THE BUILDING OWNER'S REPRESENTATIVE FOR ACCEPTANCE PRIOR TO COMMENCEMENT OF THE WORK, 6. RODENT INFESTATION PREVENTION: 1. GALVANIZED 18 GA. SHEET METAL COLLARS, SIZED TO OVERLAP OPENING AND TIGHT TO PENETRATING ITEM, AND ADHESIVE COMPATIBLE TO SURFACES ADHERED. III EXECUTION - 1. SET ALL ROUGH CARPENTRY WORK AND TEMPORARY CONSTRUCTION ACCURATELY TO REQUIRED LEVELS AND LINES WITH MEMBERS PLUMB AND TRUE AND ACCURATELY CUT AND FITTED. SECURELY ATTACH THE WORK TO SUBSTRATE BY ANCHORING AND FASTENING AS REQUIRED BY RECOGNIZED STANDARDS.TEMPORARY CONSTRUCTION ITEMS SHALL BE INSTALLED IN A WAY TO MINIMIZE MARRING AND DAMAGING EXISTING FINISHES. ALL SUCH MARRING AND DAMAGE SHALL BE CORRECTED, PATCH TO MATCH, TO NO NOTICEABLE DIFFERENCE PER SECTION 01400 OF THESE SPECIFICATIONS. 2. ' HANDLE, STORE AND INSTALL FIRE RETARDANT (FR -S) MATERIALS IN ACCORDANCE WITH MANUFACTURER'S DIRECTIONS AND AS REQUIRED TO MEET REQUIRED CLASSIFICATION OR RATING. 3. TEMPORARY CONSTRUCTION PARTITIONS, SCAFFOLDING, SCREENS, BARRIERS AND SUPPORT -S SHALL REMAIN IN PLACE UNTIL WORK IS COMPLETED. UPON COMPLETION OF THE WORK, OR PORTION THEREOF PER REQUIRED PHASING, REMOVE ITEMS IN THEIR ENTIRETY INCLUDING ALL FASTENINGS. PATCH TO MATCH AND CLEAN AND REPAIR ALL EXISTING SURFACES AFFECTED BY ITEM PLACEMENT AND SUPPORT INSTALLATION AND REMOVAL. RE -INSTALL APPLICABLE UNDAMAGED RE -USED ITEMS FOR SUCCEEDING PHASES. 4. APPLY FIRESTOPPING TO PROPERLY PREPARED CLEAN SUBSTRATE SURFACES FREE OF DIRT, DUST; GREASE, OIL, LOOSE MATERIAL, OR OTHER MATTER WHICH MAY AFFECT BOND OF FIRESTOPPING MATERIAL. APPLY PRIMER AND MATERIALS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND APPLY FIRESTOPPING MATERIAL IN SUFFICIENT THICKNESS TO ACHIEVE RATING OF SURFACE PENETRATED AND TO UNIFORM DENSITY AND TEXTURE, INSTALL MATERIAL AT FLOORS, WALLS OR PARTITION OPENINGS WHICH CONTAIN PENETRATING SLEEVES, PIPING, DUCTWORK, CONDUIT AND OTHER ITEMS REQUIRING FIRESTOPPING. 5. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 06100 06400ARCH ITEICT 1_RAL. VVO.ODW.OI?II(..: I WORK INCLUDED - 1. RELATED DOCUMENTS: I. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL 1. ARCHITECTURAL WOODWORK ITEMS AS SCHEDULED AND SHOWN ON THE DRAWINGS. 2. TEMPLATES FOR ALL WALL DISPLAYS AND OTHER AW UNITS, AS SHOWN ON THE PLANS (TEMPLATE THICKNESS TO MATCH FINISH FLOOR HEIGHT). 3. ALL MISCELLANEOUS INCIDENTAL ITEMS, INCLUDING BUT NOT LIMITED TO PLASTIC LAMINATE AND MELAMINE, WOOD VENEER AND HARDWOOD, CABINET, DISPLAY CASE, DOOR AND ROLL -UP DOOR HARDWARE, METAL TRIM, SLATWALL, GLASS AND SHEET PLASTIC, PAINT, STONE, WOOD CEILING SYSTEM, FABRIC COVERED PANELS, METAL STUD AND WOOD FRAMING, MASONITE, FASTENERS, ANCHORAGE DEVICES, SEALANTS, FILLERS AND ADHESIVES AS REQUIRED FOR THE INSTALLATION OF THE SCHEDULED ITEMS AND AS SHOWN ON THE DRAWINGS AND AS REQUIRED FOR FULL COMPLETION OF THE WORK. 2. PROVIDE COORDINATED SHOP DRAWINGS OF ALL ITEMS, SAMPLES OF SLATWALL AND ALL FINISHES, INCLUDING WOOD VENEER FLITCHES, AND ON-SITE MOCK-UPS OF ALL ITEMS, WHERE REQUESTED, IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 1. (3) 12 X12 OR (3) 8 X 10 FINISH SAMPLES. 3. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 0171Q OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS AND STAIN REMOVAL METHODS. 4. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH AW] GRADES SPECIFIED AND APPLICABLE CODES. TREAT ALL LUMBER AND WOOD WITH FIRE RETARDANT AS REQUIRED FOR TYPE, USE AND CODE MATERIALS - SEE FINISH SCHEDULE ON DRAWINGS 1. PLYWOOD OR MEDIUM DENSITY FIBERBOARD/PLASTIC LAMINATE FACED CABINET WORK AND PANELS SHALL BE AW] PREMIUM GRADE QUALITY. (USE FIRE RATED CORE MATERIAL AND FIRE RATED HORIZONTAL GRADE PLASTIC LAMINATES FOR ALL PLASTIC LAMINATE TYPES.) (THE USE OF PVC IS NOT ALLOWED.) I. PLASTIC LAMINATES: (ADHESIVES, BACKER SHEETS AND SUBSTRATES PER MANUFACTURER'S SPECIFICATIONS (TO MAINTAIN MEA RATINGS). 2. DRAWER AND CABINET INTERIORS: 1. MELAMINE CABINET INTERIORS AND BALTIC BIRCH VENEER WITH CLEAR LACQUER FINISH DRAWERS. 2. PLYWOOD OR MEDIUM DENSITY FIBERBOARD/WOOD VENEER FACED CABINET WORK AND PANELS WITH HARDWOOD EDGING SHALL BE AWI PREMIUM GRADE QUALITY FOR ALL WOOD VENEER TYPES. (USE FIRE RATED CORE MATERIAL). 3. WD1 SPECIFIED VENEER WITH A CLOSED PORE LIGHTLY STAINED SATIN LACQUER CATALYTIC FINISH, TO MATCH ARCHITECT'S SAMPLE FOR COLOR ONLY. ALL WOOD PANELED SURFACES ADJOINED OR BUTTING REVEALS ARE TO BE BOOK MATCHED WITH ALL GRAIN TO BE VERTICAL. HARDWOOD TRIM: STAINED AND FINISHED TO MATCH WD1. 4. SLATWALL: 1. SLI SPACEWALL INTERNATIONAL (800-524-1590) FIRE -RATED MEDIUM DENSITY FIBERBOARD. FINISH TO MATCH WD1 FINISH, AND CLEAR ANODIZED ALUMINUM EXTRUSION 'T': CLASS A 5. METAL "TRIM: 1. STYLMARK TRIM MAKER ANODIZED ALUMINUM- TYPE AND FINISH AS NOTED AND DETAILED ON THE DRAWINGS. (NOTE: PRE -ORDER STYLMARK ITEMS, LONG LEAD TIME, 6 WEEKS+) 3. 16 GA. SATIN STAINLESS STEEL CLADDING WITH MITERED AND RADIUSED CORNERS AND TIGHT ALIGNED FLUSH HAIRLINE BUTT JOINTS AS NOTED AND DETAILED ON THE DRAWINGS. 4. FUTURA INDUSTRIES CLEAR ANODIZED ALUMINUM 90° OUTSIDE CORNER TRIM, DIE 5116, ITEM #60080, WITH MITERED CORNERS AS NOTED AND DETAILED ON THE DRAWINGS. 6. PAINT FINISH: SEE DRAWINGS 7. CABINET, DISPLAY CASE, DOOR AND ROLL -UP DOOR HARDWARE AS NOTED ON THE DRAWINGS 8. GLASS: 1. 1/4" TEMPERED CLEAR GLASS, WITH ALL EDGES POLISHED, AS MANUFACTURED BY LOF, GLOBE AMERADA, PPG INDUSTRIES OR ARCHITECT ACCEPTED EQUAL. 2. 3/8" "TEMPERED CLEAR GLASS, WITH ALL EDGES POLISHED, AS MANUFACTURED BY LOF, GLOBE AMERADA, PPG INDUSTRIES OR ARCHITECT ACCEPTED EQUAL. 9. SHEET PLASTIC: 1. 1/8" CLEAR LEXAN, WITH ALL EDGES POLISHED 2. 1/8" BLACK LEXAN, WITH ALL EDGES POLISHED '10. SOLID SURFACING AS NOTED AND DETAILED ON THE DRAWINGS 11. METAL STUD FRAMING SYSTEMS FOR ARCHITECTURAL WOODWORK SUPPORT REQUIREMENTS. 1. IN AUDITION TO COMPLYING WITH THE PERTINENT CODES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION, COMPLY WITH PERTINENT RECOMMENDATIONS CONTAINED IN "SPECIFICATIONS FOR METAL LATHING AND FURRING" PUBLISHED BY THE METAL LATH/STEEL FRAMING ASSOCIATION. 1. METAL STUD FRAMING, UNLESS OTHERWISE SHOWN ON THE DRAWINGS, SHALL BE STANDARD PUNCHED STEEL STUDS AND TRACK OF THE SIZES AND SHAPES SHOWN ON THE DRAWINGS, EITHER ELECTROLYTIC ZINC COATING (ASTM DESIGNATION A 591, CLASS B) OR PAINTED WITH 1.0 MIL DRY FILM THICKNESS) RUST -INHIBITIVE ZINC CHROMATE PRIMER PAINT, AT MANUFACTURERS OPTION. ALL INTERIOR METAL STUDS AND THEIR ATTENDANT TRACK, LONGER THAN 12'-0" IN HEIGHT SHALL BE 20 GAUGE. Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA . � T 2. USE ONLY ONE STUD TYPE THROUGHOUT THE WORK, UNLESS OTHERWISE SHOWN ON THE DRAWINGS OR SPECIFICALLY ACCEPTED IN ADVANCE BY THE ARCHITECT. 3. PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED TO, TRACKS, SCREWS, CLIPS, ANCHORS, FASTENING DEVICES, SOUND ATTENUATION PENCIL RODS AND RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A COMPLETE, PROPER, PERMANENTLY RIGID INSTALLATION, AND AS RECOMMENDED BY THE MANUFACTURER OF THE STEEL STUDS. 4. PROVIDE A GOOD GRADE OF COMMERCIAL GROUT FOR LEVELING THE FLOOR RUNNER MEMBER OF STEEL STUD FRAMING AS REQUIRED 12. WOOD CEILING SYSTEM: WHEN SPECIFIED SEE DRAWINGS 13. MISCELLANEOUS INCIDENTAL SUPPORT ITEMS IN TYPES, SHAPES AND SIZES AS SHOWN AND/OR REQUIRED WITH SHOP PRIME FINISH FOR CONCEALED ITEMS AND SCHEDULED FINISH FOR EXPOSED TO VIEW ITEMS. '14. ALL FASTENERS, THREADED AND DRIVEN, SHALL BE THE BEST OF THEIR RESPECTIVE TYPE, GRADE AND CLASS AND SHALL BE USED INSUFFICIENT NUMBERS AND CORRECT SIZES FOR THEIR PARTICULAR APPLICATIONS. ALL FASTENERS ARE TO BE CONCEALED IN THE FINISHED WORK. 15. SEALANT FOR INSTALLATION CAULKING OF ALL ARCHITECTURAL WOODWORK ITEMS SHALL BE TREMCO, OR ARCHITECT- ACCEPTED EQUAL, HIGH PERFORMANCE SEALANT, BLACK, AND IN TYPE AND DETAIL PER MANUFACTURER'S WRITTEN RECOMMENDATIONS AND STANDARDS. COMPLY WITH SEALANT MANUFACTURER'S RECOMMENDATIONS FOR SELECTION OF CAULKING MATERIALS WHICH SUIT APPLICATIONS FOR INSTALLATION CONDITIONS. 16. ALL MISCELLANEOUS INCIDENTAL ITEMS IN TYPES SHOWN OR NOTED ON THE DRAWINGS AND AS REQUIRED FOR FULL COMPLETION OF THE WORK. III EXECUTION - I. ALL FABRICATION, FINISHING, INSTALLATION, CLEANING AND PROTECTION OF ARCHITECTURAL WOODWORK SHALL BE GOVERNED BY APPLICABLE AW] STANDARDS. TO THE MAXIMUM EXTENT POSSIBLE, ASSEMBLE ALL ITEMS IN THE SHOP INCLUDING INSTALLATION OF THE NON -WOODWORK COMPONENTS. NO HORIZONTAL SEAMS OR JOINTS ARE ALLOWED IN ANY PANELS. 2. COORDINATE EXACT LOCATIONS AND SIZES OF ALL REQUIRED CUTOUTS AND SPACE REQUIREMENT DIMENSIONS. RELOCATE ALL EXISTING WALL MOUNTED ITEMS AND DEVICES TO REMAIN TO FACE OF NEW PANELING. 3. CONDITION WOODWORK TO AVERAGE PREVAILING HUMIDITY CONDITIONS IN INSTALLATION AREAS PRIOR TO INSTALLING. 4. INSTALL THE WORK PLUMB, LEVEL, "TRUE AND STRAIGHT WITH NO DISTORTIONS. SHIM AS REQUIRED USING CONCEALED SHIMS ANG/OR LEVELERS. INSTALL TO A TOLERANCE OF '1/8" IN 8'-0" FOR PLUMB AND LEVEL (INCLUDING COUNTERTOPS); AND WITH 1/16" MAXIMUM OFFSET IN FLUSH ADJOINING SURFACE, 1/8" MAXIMUM OFFSET IN REVEALED ADJOINING SURFACES. 5. SCRIBE AND CUT WORK TO FIT ADJOINING WORK, AND REFINISH CUT SURFACES OR REPAIR DAMAGED SURFACES AT CUTS. 6. ANCHOR TO BLOCKING BUILT-IN OR DIRECTLY ATTACHED TO SUBSTRATES. SECURE TO GROUNDS, STRIPPING AND BLOCKING WITH COUNTERSUNK, CONCEALED FASTENERS AND BLIND NAILING AS REQUIRED FOR COMPLETE INSTALLATION. EXCEPT WHERE PRE -FINISHED MATCHING FASTENER HEADS ARE REQUIRED, USE FINE FINISHING NAILS FOR EXPOSED NAILING, COUNTERSUNK AND FILLED FLUSH WITH WOODWORK, AND MATCHING FINAL FINISH WHERE TRANSPARENT FINISH IS INDICATED 7. PROPERLY APPLY SEALANT IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES, MATERIALS AND DETAILS FULLY, NEATLY AND CAREFULLY, WITHIN CONFINES OF JOINT BETWEEN ARCHITECTURAL WOODWORK AND ABUTTING SURFACES. 8. SET ALL DOORS SQUARE, PLUMB, LEVEL AND TRUE, ALL IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS. DOORS SHALL OPERATE FREELY THROUGHOUT THEIR INTENDED PATH OF TRAVEL AND LOCK WITH ABSOLUTE MINIMUM FREE PLAY. ENSURE PROPER MINIMUM JOINT AND ALIGNMENT BETWEEN DOOR AND FRAME. 9. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR, EXISTING TO REMAIN AND NEW TO ENSURE PROPER OPERATION OF FUNCTION OF EVERY UNIT. REPLACE ANY UNIT WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE APPLICATION 10. MAKE FINAL CHECK AND ADJUSTMENT OF ALL HARDWARE ITEMS. CLEAN OPERATING ITEMS AS NECESSARY TO RESTORE PROPER FUNCTION AND FINISH OF HARDWARE AND DOORS. ADJUST DOOR CONTROL DEVICES TO COMPENSATE FOR FINAL OPERATION OF HEATING AND VENTILATING EQUIPMENT. 11, INSTRUCT OWNER'S PERSONNEL IN PROPER ADJUSTMENT AND MAINTENANCE OF HARDWARE FINISHES, DURING THE FINAL ADJUSTMENT OF HARDWARE. 12. APPLY FABRIC PANEL COVERING TO SOUND, SMOOTH, DRY AND PROPERLY PREPARED PANEL SURFACES BY DIRECT GLUE -DOWN METHOD USING MANUFACTURER'S RECOMMENDED ADHESIVE. ALL MATERIALS SHALL BE INSTALLED WITH TIGHT NEAT CORNERS SECURE, SMOOTH, WITHOUT WRINKLES, GAPS OR OVERLAPS. JOINTS ARE TO BE UN -NOTICEABLE. 13. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 06400 07900 JOINT SEALERS: 2. SIDE FOLDING CLOSURE(S): 5. WIRE CLIPS: 99 SPRING STEEL. I WORK INCLUDED - '1. MANUALLY OPERATED, (BI -PARTING) ASSEMBLY(IES) WITH CLEAR III EXECUTION - ANODIZED MILL ALUMINUM FINISH / PERFORATED STEEL PANEL CURTAIN. PROVIDE 1. RELATED DOCUMENTS: INSIDE/OUTSIDE CYLINDER LOCK WITH DUSTPROOF FLOOR STRIKE AND EGRESS 1. INSTALL ALL GYPSUM WALLBOARD WORK IN ACCORDANCE DOORS FOR EMERGENCY EXIT. WITH THE GYPSUM WALLBOARD MANUFACTURER'S WRITTEN TECHNICAL INFORMATION, 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL GYPSUM CONSTRUCTION HANDBOOK LATEST EDITION. AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY 1. DYNAMIC CLOSURES, (800-663-4599), OR TO THIS SECTION. 2. DYNAFLAIR, (813-248-8100), MODEL "SENTRY", OR 2. EXISTING DEMISING WALLS ARE TO BE RETROFITTED AS 3. MOBILFLEX (800-501-3539), MODEL "AEROFLEX", OR REQUIRED TO MAINTAIN REQUIRED FIRE RATING. NEW WORK SHALL ACCOMMODATE 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS 4. METRO DOOR, (800-669-3667) OR EXISTING RELOCATED AND NEW BUILT-IN ELECTRICAL DEVICES: COORDINATE WITH WHICH AFFECT" WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS 5. ARCHITECT ACCEPTED EQUAL ELECTRICAL DRAWINGS. SPECIFICALLY MENTIONED IN THIS SECTION. III EXECUTION - 3. INSTALL ALL GYPSUM WALLBOARD PLUMB LEVEL, SQUARE 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AND TRUE WITHOUT DISTORTION, ALIGNED AND FITTED PROPERLY, TAPED FLUSH AND AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE 1. INSTALLATION SHALL BE BY CLOSURE MANUFACTURER'S SMOOTH, ACCEPTABLE FOR APPLIED FINISHES. INSTALL METAL TRIM AND METAL TRIM THE STEADY PROGRESS OF ALL PROJECT WORK. AUTHORIZED DISTRIBUTOR OR REPRESENTATIVE. ACCESSORIES AT ALL EXPOSED TO VIEW CORNERS, EXTERNAL AND INTERNAL, AND ALL EXPOSED TO VIEW ENDS. 2. PROVIDE AND INSTALL: 2. COORDINATE EXACT LOCATIONS AND SIZES OF ALL REQUIRED CUTOUTS, AND SPACE REQUIREMENTS AND DIMENSIONS FOR SUPPORT AND FINISH 4. COORDINATE EXACT LOCATIONS AND SIZES OF ALL REQUIRED 1. ALL CAULKING FOR THE INSTALLATION OF NEW WORK WHERE NOTED AND/OR REQUIREMENTS WITH OTHER SECTIONS OF THESE SPECIFICATIONS AND AS SHOWN CUTOUTS, AND SPACE REQUIREMENTS AND DIMENSIONS FOR SUPPORT AND REQUIRED INCLUDING ALL MECHANICAL AND ELECTRICAL WORK. AND NOTED ON THE DRAWINGS: ENCLOSED ABUTTING MATERIAL REQUIREMENTS WITH OTHER SECTIONS OF THESE SPECIFICATIONS AND AS SHOWN AND NOTED ON THE.DRAWINGS: 2. ALL ADHESIVES, BACK-UP MATERIALS AND INCIDENTAL MATERIALS REQUIRED 1. MISCELLANEOUS METALS SECTION 05500 FOR PROPER INSTALLATION OF THE ABOVE. 2. CARPENTRY SECTION 06100 1. MISCELLANEOUS METALS SECTION 05500 3. ARCHITECTURAL WOODWORK SECTION 06400 2. CARPENTRY SECTION 06100 3. PROVIDE MANUFACTURER'S PRODUCT DATA LITERATURE ON ALL ITEMS, 4. GYPSUM WALLBOARD SECTION 09250 3. ARCHITECTURAL WOODWORK SECTION 06400 SAMPLES OF CAULKING AND SAMPLES OF OTHER ITEMS AS MAY BE REQUESTED BY 5. ELECTRICALSEE DRAWINGS 4. MECHANICAL SEE MECHANICAL DRAWINGS THE ARCHITECT IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 5. ELECTRICAL SEE ELECTRICAL DRAWINGS 3. SET DOOR SUPPORT, ENCLOSURES AND ABUTTING ADJACENT 4. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 01710 OF THESE WORK SQUARE, PLUMB, LEVEL AND TRUE, ALL IN ACCORDANCE WITH THE CLOSURE 5. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS MANUFACTURER'S WRITTEN INSTRUCTIONS. CURTAIN(S) SHALL OPERATE FREELY 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. AND STAIN REMOVAL METHODS. THROUGHOU-T (TTS) (THEIR) INTENDED PATI-I(S) OF TRAVEL WITH ABSOLUTE MINIMUM FREEPLAY. ENSURE PROPER MINIMUM JOINT AND ALIGNMENT BETWEEN CURTAIN END OF SECTION 09250 5. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH SWRI, GUIDES AND STOREFRONT ENCLOSURES. SEALANT AND CAULKING GUIDE SPECIFICATION, IMIAC AND APPLICABLE CODE REQUIREMENTS AND SHALL BE OF THE HIGHEST QUALITY IN MATERIAL AND 4. INSTRUCT OWNER'S PERSONNEL IN PROPER ADJUSTMENT Q950 HARDWOOD FLOORING: INSTALLATION STANDARDS FOR THE TYPE APPLICATION AND METHOD OF AND MAINTENANCE OF CLOSURE(S), DURING THE FINAL ADJUSTMENT OF CLOSURE CONSTRUCTION IN ACCORDANCE WITH THE MANUFACTURER'S WRITTEN INSTALLATION(S). I WORK INCLUDED - RECOMMENDATIONS TO ACHIEVE A WATERTIGHT INSTALLATION GUARANTEE AGAINST ALL DEFECTS IN MATERIAL AND WORKMANSHIP FOR A PERIOD OF TWO (2) YEARS. 5. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 1. RELATED DOCUMENTS. 01400, 01600 AND 01710 OF THESE SPECIFICATIONS.' 6. WORK NOT INCLUDED: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING END OF SECTION 08300 GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1, GENERAL 1. SEALANTS SPECIFIED IN OTHER SECTIONS - REQUIREMENTS OF THESE SPECIFICATIONS, APPLY TO THIS SECTION. 1. ARCHITECTURAL WOODWORK SECTION 0(3400 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR Q950 GYPSUM WALLBOARD: REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. II MATERIALS - I WORK INCLUDED - 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR 1. TREMCO, OR ARCHITECT ACCEPTED EQUAL, HIGH PERFORMANCE 1. RELATED DOCUMENTS: AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE SEALANTS, IN, STANDARD COLORS SELECTED BY ARCHITECT AND IN TYPE AND DETAIL THE STEADY PROGRESS OF ALL PROJECT WORK. PER MANUFACTURER'S WRITTEN RECOMMENDATIONS AND STANDARDS. COMPLY WITH 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING SEALANT MANUFACTURER'S RECOMMENDATIONS FOR SELECTION OF CAULKING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL 2. PROVIDE AND INSTALL: MATERIALS WHICH SUIT APPLICATIONS FOR INSTALLATION CONDITIONS. REQUIREMENTS, APPLY TO THIS SECTION. 1. ALL HARDWOOD STRIP FLOORING AS SHOWN AND SCHEDULED ON THE 2. INCIDENTAL MATERIALS INCLUDING BUT NOT LIMITED TO BACK-UP 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR DRAWINGS. MATERIALS, ADHESIVES, BOND BREAKERS, TAPE, PRIMERS AND FASTENERS REQUIRED REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH AND COMPATIBLE AND IN ACCORDANCE WITH MATERIAL MANUFACTURER'S WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 2. TRANSITION STRIPS AS SHOWN ON THE DRAWINGS. RECOMMENDATIONS. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR 3. ALL SETTING MATERIALS AND INSTALLATION PRODUCTS FOR ABOVE III EXECUTION - AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE HARDWOOD STRIP FLOORING AND TRANSITION STRIPS. THE STEADY PROGRESS OF ALL PROJECT WORK. 1. PROPERLY PREPARE AND CLEAN ALL EXISTING AND NEW SURFACES TO 3. SUBMITTALS: RECEIVE APPLIED MATERIALS AND VERIFY THAT ALL SURFACES TO RECEIVE 2. PROVIDE AND INSTALL: MATERIALS ARE PROPERLY PREPARED AND READY IN ACCORDANCE WITH MATERIAL 1. PROVIDE SAMPLES OF STRIP FLOORING, SHOP DRAWINGS ON MANUFACTURER'S WRITTEN INSTRUCTIONS. '1. GYPSUM WALLBOARD PARTITION TYPES, CEILINGS, FSACIA/SOFFITS, TERMINATION DETAILS AND MANUFACTURER'S PRODUCT DATA LITERATURE IN ARCHITECTURAL WOODWORK BACK-UP ASSEMBLIES, PARTITION RETROFITS, FURRING ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 2. PROPERLY APPLY ALL MATERIALS TO ALL SURFACES IN ACCORDANCE WITH AND PATCHING THROUGHOUT AS SHOWN AND SCHEDULED ON THE DRAWINGS. MANUFACTURER'S RECOMMENDED INSTALLATION PROCEDURES, MATERIALS AND 2. INSTALLER CERTIFICATION: SUBMIT A LIST OF AT LEAST THREE INSTALLATIONS DETAILS. 3. PROVIDE MANUFACTURER'S LITERATURE IN ACCORDANCE SUCCESSFULLY COMPLETED WITHIN THE PAST YEAR REQUIRING THE SAME GENERAL WITH SECTION 01300 OF THESE SPECIFICATIONS. DEGREE OF INSTALLATION EXPERTISE. 3. APPLY SEALANTS FULL AND CONTINUOUS NEATLY AND CAREFULLY, WITHIN CONFINES OF JOINT, WITH CONCAVE PROFILES, AT ALL JOINTS INDICATED ANG/OR 4. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 3. SUBMIT MAINTENANCE DATA IN ACCORDANCE WITH SECTION 01710 OF REQUIRED. 01710 AND OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING CLEANING MATERIALS, STAIN REMOVAL METHODS. MATERIALS, STAIN REMOVAL METHODS, AND POLISHES AND WAXES, END OF SECTION 07900 5. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE 4. QUALITY ASSURANCE: WITH MANUFACTURER'S INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. 1. ALL WORK AND MATERIALS SHALL BE HIGHEST QUALITY IN ACCORDANCE 083.00 SPECIAL DOORS _ II MATERIALS - WITH THE LATEST RECOMMENDATIONS, STANDARDS AND REQUIREMENTS OF THE STRIP FLOORING MANUFACTURER'S WRITTEN TECHNICAL INFORMATION, TILE COUNCIL I WORK INCLUDED - 1. ALL GYPSUM WALLBOARD MATERIALS INCLUDING BUT NOT OF AMERICA CONSTRUCTION HANDBOOK, AND CODE ASSEMBLY REQUIREMENTS AND LIMITED TO: STEEL STUD FRAMING COMPONENTS, REGULAR BOARD, FIRECODE C TYPE ASTM AND NOFMA STANDARDS. 1. RELATED DOCUMENTS: X FIRE RATED BOARD, SOUND INSULATION AND SEALANT, ADHESIVES, METAL TRIM, METAL TRIM ACCESSORIES, CORNER TRIM, TAPE, JOINTING COMPOUND AND 2. MANUFACTURER: COMPANY SPECIALIZING IN THE PRODUCTION OF ENGINEERED 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL MISCELLANEOUS INCIDENTAL MATERIALS REQUIRED FOR THE NEW WORK AND MULTIPLY CONSTRUCTIN BONDED HARDWOOD FLOORING WITH A MINIMUM FIVE YEARS AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY PATCHING OF EXISTING SHALL BE U.S. GYPSUM QUALITY OR ARCHITECT ACCEPTED DOCUMENTED EXPERIENCE. TO THIS SECTION. EQUAL: 3. INSTALLER: SPECIALIZING IN PERFORMING THE WORK OF THIS SECTION 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS 1, PROVIDE STANDARD PUNCHED STEEL STUDS AND TRACK OF THE SIZES WITH A MINIMUM FIVE YEARS DOCUMENTED EXPERIENCE AND APPROVED BY THE WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS AND SHAPES SHOWN ON THE DRAWINGS, EITHER ELECTROLYTIC ZINC COATING (ASTM MANUFACTURER. SPECIFICALLY MENTIONED IN THIS SECTION. DESIGNATION A 591, CLASS B) OR PAINTED WITH -1.0 MIL DRY FILM THICKNESS) RUST -INHIBITIVE ZINC CHROMATE PRIMER PAINT, AT MANUFACTURERS OPTION. ALL II MATERIALS - 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR INTERIOR METAL STUDS, AND THEIR ATTENDANT TRACK, OVER 12'-0" IN HEIGHT SHALL AFFECTED BY WORK OFT HIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE BE 20 GAUGE. 1. WOOD FLOORING: THE STEADY PROGRESS OF ALL PROJECT WORK. 2. USE ONLY ONE TYPE THROUGHOUT THE WORK, UNLESS OTHERWISE 1. SEE FINISH SCHEDULE 2. PROVIDE AND INSTALL: SHOWN ON THE DRAWINGS OR SPECIFICALLY ACCEPTED IN ADVANCE BY THE ARCHITECT. 2. EXTRA MATERIALS: 1. SIDE FOLDING CLOSURE OR MOTOR OPERATED OVERHEAD ROLLING CLOSURE ASSEMBLY(IES) AS SHOWN AND SCHEDULED ON THE DRAWINGS, INCLUDING 3. PROVIDE ALL ACCESSORIES INCLUDING, BUT NOT NECESSARILY LIMITED 1. PROVIDE 6 SQ. YD. OF EXTRA FLOORING MATERIAL. ASSOCIATED ELECTRICAL WORK, HOOK-UP AND TESTING, OF ROLLING CLOSURE(S), TO, TRACKS, SCREWS, CLIPS, ANCHORS, FASTENING, DEVICES, SOUND ATTENUATION SEE'E' DRAWINGS PENCIL RODS AND RESILIENT CLIPS, AND OTHER ACCESSORIES REQUIRED FOR A 2. TRANSITION STRIPS: COMPLETE AND PROPER INSTALLATION, AND AS RECOMMENDED BY THE 3. COORDINATE ALL WORK OF OTHER SECTIONS FOR THE CLOSURES. MANUFACTURER OF THE STEEL STUDS. 1. AIRPORT STANDARD TRANSITION STRIP 4. PROVIDE COORDINATED SHOP DRAWING FOR CLOSURE REQUIREMENTS, 4. PROVIDE A GOOD GRADE OF COMMERCIAL GROUT FOR LEVELING THE INCLUDING BUT NOT NECESSARILY LIMITED TO; SUPPORT FRAMING AND ENCLOSURES, FLOOR RUNNER MEMBER OF STEEL STUD PARTITIONS AS REQUIRED III EXECUTION - PER CLOSURE MANUFACTURER'S LITERATURE IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 2. SUSPENSION SYSTEM MATERIALS: 1. EXAMINATION: 5. PROVIDE CLEANING AND MAINTENANCE DATA IN ACCORDANCE WITH 1. BOLT 3 X 3 X 1/4 X 2 LONG SUPPORT ANGLES TO EXISTING STRUCTURAL 1. VERIFY THAT CEMENTITIGUS UNDERLAYMENT, SEE SECTION 03500, IS SECTIONS 01710 AND 01 730 OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CONCRETE OR SUPPLEMENT EXISTING INTERMEDIATE FRAMING MEMBERS AS PROPERLY INSTALLED AND IS COMPATIBLE WITH WOOD FLOORING ADHESIVE TO BE CLEANING METHODS, CLEANING MATERIALS, STAIN REMOVAL METHODS. REQUIRED FOR NEW SUSPENSION SYSTEM WITH UNISTRUT CHANNELS AND IS CLEAN AND FREE OF ALL LAITANCE, LOOSE MATERIALS, GREASE, OIL, AND SCREW FASTENED TO EXISTING STRUCTURAL STEEL MEMBERS SPACED 4 FOOT 0 OTHER CONTAMINANTS THAT WILL INTERFERE WITH THE BONDING OF THE ADHESIVE IN 6. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH INCHES ON CENTER BETWEEN EXISTING STRUCTURAL MEMBERS. ACCORDANCE WITH THE FLOORING MANUFACTURER'S WRITTEN TECHNICAL MANUFACTURER'S WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. INFORMATION AND APPLICABLE ASTM STANDARDS. 2. SECURE TO SUPPORT ANGLES OR INTERMEDIATE FRAMING MEMBERS BY TIEING GUY WIRES OR INSERTING BENT END OF HANGER RODS THROUGH PRE -PUNCHED HOLES (4'-0" ON CENTERS IN INTERMEDIATE FRAMING MEMBERS) SIZED II MATERIALS - FOR NOT LESS THAN 3 TIMES THE HANGER DESIGN LOAD FOR THE STRUCTURAL CLASSIFICATION INDICATED; ASTM DESIGNATION C 635, TABLE 1, INDIRECT HUNG. 1. OVERHEAD ROLLING CLOSURE(S): 3. CEILING ATTACHMENT TO BUILDING SYSTEM SHALL BE THROUGH HANGER 1. MOTOR OPERATED, COUNTERBALANCE ASSEMBLY(IES) WITH CLEAR ANODIZED RODS, GUY WIRES, UNISTRUT AND STEEL CHANNELS AS SHOWN ON THE DRAWINGS: ALUMINUM (MT_) FINISH / PERFORATED PANEL CURTAIN. PROVIDE OUTSIDE/INSIDE KEY SWITCHES, ELECTRIC INTERLOCKS, ELECTRO MAGNETIC BRAKE, INSIDE EMERGENCY 1. HANGERS SHALL BE 1/4 INCH DIAMETER STEEL RODS. HANGER RODS SHALL BE RELEASE SYSTEM AND 4" WIDE BOTTOM RAIL CLOSURE PLATE WITH PAINTED (P_) GALVANIZED CONFORMING TO APPLICABLE PROVISIONS OF ASTM DESIGNATION A 123. FINISH, PER SECTION 09900,,BY: 2. GUY WIRES SHALL BE 12 GAUGE WIRE. 1. DYNAMIC CLOSURES, (800-663-4599), MODEL "PARAVENT", OR 2. DYNAFLAIR, (813-248-8100), OR 3. UNISTRUT SHALL- BE P-1001 WITH BEAM CLAMPS AND ANGLE FITTINGS. 3. METRO DOOR, (800-669-3667) OR 4. ARCHITECT ACCEPTED EQUAL 4. STEEL CHANNELS: EITHER COLD ROLLED AT 0.475 LB, PER FT. OR HOT -ROLLED FOR SUPPORT OF CEILING RUNNERS WITH DEFLECTIONS LESS THAN 1/360 X SPANS; BUT IN NO CASE LESS THAN 1-1/2 INCH SECTION WEIGHING 0.475 POUNDS PER LINEAR FOOT, AND IN NO CASE LESS THAN REQUIRED BY GOVERNING REGULATIONS OR FOR FIRE RESISTANCE. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 2. VERIFY THAT UNDERLAYMENT IS AT HEIGHT AND LEVEL TO MAKE WOOD FLOORING FLUSH, EVEN AND CONTINUOUS WITH ABUTTING FLOORING AND TRANSITION STRIPS AS DETAILED. 2. INSTALLATION: 1. INSTALL WOOD FLOORING WORK IN ACCORDANCE WITH THE FLOORING MANUFACTURER'S WRITTEN TECHNICAL INFORMATION FOR DIRECT -BOND INSTALLATION AND APPLICABLE ASTM STANDARDS. 1. INSTALL TRANSITION STRIPS AS REQUIRED FOR A CONTINUOUS SMOOTH, SOUND, LEVEL, AND FLUSH INSTALLATION WITH A MINIMUM NUMBER OF TIGHT HAIRLINE BUTT JOINTS, FLUSH AND LEVEL TO ABUTTING HARDWOOD FLOORING AND ABUTTING EXITING FINISH FLOOR SURFACES AS' SHOWN AND DETAILED. 2. LAY FLOORING AS INDICATED ON THE DRAWINGS. ARRANGE FLOORING WITH END MATCHED GRAIN SET FLUSH AND TIGHT. TOOTH IN ALL FLOORING DIRECTIONAL CHANGES. VERIFY ALIGNMENT AS WORK PROGRESSES. 3. COORDINATE INSTALLATION WITH THE WORK OF ALL OTHER SECTIONS OF THESE SPECIFICATIONS. 4. CLEAN AND PROTECT FINISHED FLOOR SURFACES IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 IN DIVISION 1 OF THESE SPECIFICATIONS. DO NOT PERMIT TRAFFIC OVER FINISHED FLOOR SURFACE FOR 4 DAYS AFTER INSTALLATION. END OF SECTION 09550 0.9�OQ ACOUSTICAL TREATMENT; I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL: 1. SUSPENDED ACOUSTICAL PANEL CEILING(S) AND GRID SYSTEM(S) AS SCHEDULED AND SHOWN ON THE DRAWINGS. 3. COORDINATE ALL CUTOUTS AND BUILT-IN REQUIREMENTS OF PERTINENT SECTIONS OF THESE SPECIFICATIONS OF THESE SPECIFICATIONS, INCLUDING MECHANICAL AND ELECTRICAL WORK: SEE MECHANICAL AND ELECTRICAL DRAWINGS. 4. COORDINATE ALL SUSPENDED ENCLOSURES, SIGNAGE AND ABUTTING WALL AND FASCIA CONDITIONS, NEW AND EXISTING, DESCRIBED IN PERTINENT SECTIONS OF THESE SPECIFICATIONS. 5. PROVIDE FINISH SAMPLES AND MANUFACTURER'S LITERATURE . ON ALL ITEMS IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 6. SUBMIT CLEANING DATA IN ACCORDANCE WITH SECTION 01710 OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS AND STAIN REMOVAL METHODS. 7. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH CISCA WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. II MATERIALS - 1. INTERIOR SUSPENDED ACOUSTICAL CEILING PANELS AND GRID TO FIT CEILING AREAS AND CONDITIONS AS INDICATED ON FINISH SCHEDULE ON DRAWINGS. 2. ALL CEILING JOISTS, SUPPORT ANGLES, FIANGER RODS, STRUTS, GUY WIRE, CLIPS, BLACK IRON, FASTENERS, ATTACHMENTS, WALL MOLDING AND MISCELLANEOUS INCIDENTAL MATERIALS REQUIRED FOR THE INSTALLATION OF THE ABOVE ITEMS APPROVED BY THE CEILING MANUFACTURER AND IN ACCORDANCE WITH ALL APPLICABLE BUILDING CODES. EXECUTION - 1. INSTALL ALL CEILING JOISTS, BLACK IRON, HANGER RODS, STRUTS, GUY WIRE, CLIPS, BLACK IRON, FASTENERS, ATTACHMENTS, WALL MOLDING AND MISCELLANEOUS INCIDENTAL MATERIALS IN ACCORDANCE WITH THE STANDARD BUILDING CODE REQUIREMENTS TO RECEIVE THE SUSPENDED ACOUSTICAL PANEL CEILING GRIDS. 2. INSTALL ALL CEILING PANELS AND GRIDS LEVEL AND TRUE'TO SUSPENSION SYSTEM TO FIT CEILING AREAS AS SHOWN AND IN ACCORDANCE WITH THE CEILING MANUFACTURER'S WRITTEN INSTRUCTIONS. COORDINATE WITH NEW DUCTWORK CONDITIONS, DIFFUSERS, RETURNS, LIGHTING FIXTURES, SPEAKERS AND SIGNAGE. INSTALL CEILING GRID TO THE SUSPENSION GRID WITH START POINTS AS SHOWN AT CEILING HEIGHTS INDICATED. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IMMEDIATELY. CAREFULLY CUT, SUPPORT AND INSTALL ALL PERIMETER PANELS WITH WALL MOLDING. FINISH ALL EXPOSED TO VIEW CUT PANEL EDGES TO MATCH UNCUT PANEL FINISHED EDGE, 3. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, Q1400,01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 09500 09900 PAINTING: I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL: 1. PROPERLY PREPARE, PRIME AND FINISH PAINT ALL GYPSUM WALLBOARD WALL, CEILING AND SOFFIT/FASCIA SURFACES AS SCHEDULED AND SHOWN ON THE DRAWINGS. 2. PROPERLY PREPARE AND FINISH PAINT ALL MISCELLANEOUS INCIDENTAL (MATERIALS AS NOTED ON THE DRAWINGS INCLUDING BUT NOT LIMITED TO; DIFFUSERS, REGISTERS, PIPING, CONDUIT, BOXES, LIGHTING FIXTURES, PANELBOARDS, ETC. EXPOSED TO VIEW. 3. PROPERLY PREPARE AND FINISH PAINT EXISTING DAMAGED, MARRED OR WORN SURFACES TO REMAIN AND PATCH TO MATCH WORK AS REQUIRED FOR THE INSTALLATION OF NEW WORK, INCLUDING MECHANICAL AND ELECTRICAL. 3. PROVIDE FINISH SAMPLES OF EACH TYPE COLOR AND ON-SITE SAMPLE AREAS FOR REVIEW ACCEPTANCE BY THE ARCHITECT AS NOTED IN THIS SPECIFICATION IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 1. (4) 12 X 12 OR (4) 8 X 10 FINISH SAMPLES. 4. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 01710 AND OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS, STAIN REMOVAL METHODS. 5. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH MANUFACTURER'S WRIT'T'EN SPECIFICATIONS AND APPLICABLE CODE REQUIREMENTS. 6. WORK NOT INCLUDED: 1. UNLESS OTHERWISE INDICATED, PAINTING IS NOT REQUIRED ON SURFACES IN CONCEALED AREAS AND INACCESSIBLE AREAS SUCH AS FURRED SPACES, FOUNDATIONS SPACES, UTILITY -FUNNELS, PIPE SPACES, AND DUCT SHAFTS. 2. METAL SURFACES OF ANODIZED ALUMINUM, STAINLESS STEEL, CHRQM:'JM PLATE, COPPER, BAKED ENAMEL, BRONZE, AND SIMILAR FINISHED MATERIALS WILL NOT REQUIRE PAINTING UNDER THIS SECTION EXCEPT AS MAY BE SO SPECIFIED. 3. DO NOT PAINT MOVING PARTS OF OPERATING UNITS, MECHANICAL OR ELECTRICAL PARTS SUCH AS VALVE OPERATORS, LINKAGE, SENSING DEVICES, AND MOTOR SHAFTS, UNLESS OTHERWISE INDICATED. 4. DO NOT PAINT OVER REQUIRED LABELS OR EQUIPMENT IDENTIFICATION,. PERFORMANCE RATING, NAME, OR NOMENCLATURE PLATES. DO NOT PAINT FINISH HARDWARE UNLESS PRIME COATED. 5. PAINTING SPECIFIED IN OTHER SECTIONS OF THESE SPECIFICATIONS: 1. SECTION 06400 ARCHITECTURAL WOODWORK 2. SECTION 10400 IDENTIFYING DEVICES MATERIALS 1. PAINT TYPES: SEE FINISH SCEDULE ON DRAWINGS 2. PRIMERS FOR THE ABOVE PAINT TYPES AS MANUFACTURED BY THE PAINT TYPE MANUFACTURER FOR SUBSTRATE TO BE PAINTED. 3. HEALTH SPEC LOW ODOR, LOW VOLATILE ORGANIC COMPOUNDS (VOC) COMPLIANT MATERIALS ARE ONLY TO BE USED. DO NOT THIN ALKYD BASED MATERIALS OTHERWISE VOC RATING WILL BE COMPROMISED. VOC PAINTS REQUIRE LONGER DRYING TIME. 4. UPON COMPLETION OF THE WORK OF THIS SECTION, DELIVER TO THE OWNER AND EXTRA STOCK EQUALING 10% EACH COLOR, TYPE AND CLASS OF PAINT USED IN THE WORK, TIGHTLY SEALING EACH CONTAINER, AND CLEARLY LABELING EACH CAN WITH CONTENTS AND LOCATION WHERE USED. EXECUTION - 1. EXAMINE SURFACES TO BE PAINTED AND REPORT ANY CONDITIONS THAT WOULD ADVERSELY AFFECT THE APPEARANCE OR PERFORMANCE OF THE PAINTING SYSTEMS. 2. PROPERLY PREPARE, CLEAN AND PRIME ALL EXISTING AND NEW SURFACE SUBSTRATES TO RECEIVE PAINTING SYSTEMS IN ACCORDANCE WITH THE MATERIAL MANUFACTURER'S SPECIFICATIONS. PATCH, REPAIR AND FILL FLUSH ALL DAMAGE, DEFECTS, AND OTHER MARRINGS TO EXISTING AND NEW SURFACES TO BE PAINTED. 3. REMOVE ELECTRICAL PLATES, HARDWARE, LIGHT FIXTURE TRIM, SIGNS, ESCUTCHEONS AND FITTINGS PRIOR TO PREPARING SURFACES OR FINISHING. SIGNS ARE TO BE REPLACED IN LOCATIONS AS DIRECTED BY OWNER AFTER PAINT FINISH ACCEPTANCE. MASK OFF ALL MECHANICAL AND ELECTRICAL OPERATING DEVICES AND IDENTIFICATION MARKINGS, FIRE PROTECTION SPECIALTIES, DOORS, FRAMES AND HARDWARE AND OTHER MISCELLANEOUS ITEMS AS REQUIRED AND ALL ABUTTING SURFACES SCHEDULED OR NOTED TO RECEIVE A DIFFERENT PAINT TYPE OR FINISH. 4. APPLY PAINT COATS BY SPRAY, ROLLER AND BRUSH APPLICATION ONLY TO SOUND, SMOOTH, DRY AND PROPERLY PREPARED SURFACES IN A DUST FREE ENVIRONMENT IN ACCORDANCE WITH THE PAINT MANUFACTURER'S WRITTEN INSTRUCTIONS. FILL ALL DAMAGED, MARRED, SCRAPED AND DENTED SURFACES WITH APPROPRIATE FILLER MATERIAL, METAL OR WOOD, AND SAND/POLISH SMOOTH AND SMOOTH WITH ABUTTING SURFACES. ALL WORK SHALL RECEIVE ONE PRIME COAT AND TWO FINISH COATS. ALL COMPLETED WORK SHALL BE UNIFORM IN APPEARANCE Al D COVERAGE, FREE OF HOLIDAYS, SPOTTING, LAPS, TOOL MARKS, RUNS, SAGS, OR OTHER SURFACE IMPERFECTIONS. 1. EXCEPT AS SPECIFICALLY OTHERWISE ACCEPTED BY THE ARCHITECT, CONFINE SPRAY APPLICATION TO TVIETAL FRAMEWORK AND SIMILAR SURFACE WHERE HAND BRUSH WORK WOULD BE INFERIOR. 5. MISCELLANEOUS SURFACES AND PROCEDURES 1. PAINT ALL DAMAGED EXISTING PAINT SURFACES COLOR AND FINISH TO MATCH EXISTING LIKE FINISHED SURFACE. 2. HARDWARE: PAINT PRIME COATED HARDWARE TO MATCH ADJACENT SURFACES. 3. ALUMINUM SURFACES SCHEDULED FOR PAINT FINISH: REMOVE SURFACE CONTAMINATION BY STEAM OR HIGH PRESSURE WATER. REMOVE OXIDATION WITH ACID ETCH AND SOLVENT WASHING. APPLY ETCHING PRIMER IMMEDIATELY FOLLOWING CLEANING. 4. SEAL WITH SHELLAC AND SEAL ALL MARKS WHICH MAY BLEED THROUGH SURFACE FINISHES. 6. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. . END OF SECTION 09900 1040 IDENTIFYING D �CICE% I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL: 1. SIGN(S) AS SCHEDULED AND SHOWN ON THE DRAWINGS. 2. ALL MOUNTING DEVICES AND FASTENERS REQUIRED FOR THE INSTALLATION OF THE ABOVE SIGN AND MAP ASSEMBLIES. 3. PROVIDE COORDINATED SHOP DRAWINGS AND MANUFACTURER'S LITERATURE ON ALL ITEMS IN ACCORDANCE WITH THESE SPECIFICATIONS. 4. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 0.1710 AND 0 � THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS, STAIN REMOVAL METHODS. 5. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. Hudson News - Hudson BookseHers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA II MATERIALS 1. STOREFRONT FASCIA SIGN: 1. SIGN AS INDICATED ON DRAWINGS AND ARCHITECT APPROVED SIGN DRAWINGS. III EXECUTION - 1. COORDINATE EXACT LOCATIONS AND SIZES OF ALL REQUIRED CUTOUTS AND SPACE REQUIREMENTS AND DIMENSIONS WITH OTHER SECTIONS OF THESE SPECIFICATIONS AND AS NOTED ON THE DRAWINGS: 1. SECTION 06400 ARCHITECTURAL WOODWORK 2. SECTION 092.50 GYPSUM WALLBOARD 2. 'E' DRAWINGS ELEC"T"RICAL 2. . INSTALL ALL WORK TRUE PLUMB, RIGID AND PERMANENT IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 10400 1144 APPS_ LANCES: I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. INSTALL ONLY: OWNER SUPPLIED CONTRACTOR INSTALLED (OSCI) 1. REFRIGERATOR(S) AS SHOWN ON THE DRAWINGS. 3. PROVIDE AND INSTALL: 1. POWER REQUIREMENTS, SEE ELECTRICAL DRAWINGS 4. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. II MATERIALS -. 1. EQUIPMENT AS SHOWN ON DRAWINGS - (USCI). III EXECUTION - 1. COORDINATE EXACT LOCATIONS, SIZE AND SPACE REQUIREMENT DIMENSIONS WITH OTHER SECTIONS OF THESE SPECIFICATIONS AND AS NOTED ON THE DRAWINGS: 1. ARCHITECTURAL WOODWORK SECTION 06400 2. ELECTRICAL SEE'E' DRAWINGS 2. INSTALL REFRIGERATOR(S) LEVEL, TRUE AND PLUMB IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. CLEAN AND PROTECT REFRIGERATOR(S) IN ACCORDANCE WITH SECTIONS 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 11450 126-70 RUGS AICD MATS I WORK INCLUDED - 1. RELATED DOCUMENTS: 1. DRAWINGS AND GENERAL PROVISIONS OF THE CONTRACT, INCLUDING GENERAL AND SUPPLEMENTARY CONDITIONS AND DIVISION 1 GENERAL REQUIREMENTS, APPLY TO THIS SECTION. 2. EXAMINE ALL OTHER SECTIONS OF THE SPECIFICATIONS FOR REQUIREMENTS WHICH AFFECT WORK OF THIS SECTION. WHETHER OR NOT SUCH WORK IS SPECIFICALLY MENTIONED IN THIS SECTION. 3. COORDINATE WORK WITH THAT OF ALL OTHER TRADES AFFECTING, OR AFFECTED BY WORK OF THIS SECTION. COOPERATE WITH SUCH TRADES TO ASSURE THE STEADY PROGRESS OF ALL PROJECT WORK. 2. PROVIDE AND INSTALL: 1. ANTI -FATIGUE MAT(S) AT CASHWRAP(S) AS SHOWN ON THE DRAWINGS. 3. ALL SETTING MATERIALS AND ADHESIVES REQUIRED FOR THE INSTALLATION OF THE ABOVE. 4. PROVIDE MAT JOINT LOCATION PLANS, FINISH SAMPLES AND MANUFACTURER'S LITERATURE ON ALL ITEMS IN ACCORDANCE WITH SECTION 01300 OF THESE SPECIFICATIONS. 5. PROVIDE CLEANING DATA IN ACCORDANCE WITH SECTION 01710 AND OF THESE SPECIFICATIONS. INCLUDE RECOMMENDED CLEANING METHODS, CLEANING MATERIALS, STAIN REMOVAL METHODS. 6. ALL WORK SHALL BE HIGHEST IN QUALITY IN COMPLIANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS AND APPLICABLE CODE REQUIREMENTS. II MATERIALS - 1. MAT: 1. VERIFY SUPPLIER WITH TENANT OR ALTERNATE - MATS, INC. (800-628-7462) REMOVABLE ROLL -UP CUSHION EZE, DARK GRAY, 1/2" THICK, DURABLE MARBLEIZED VINYL, ADHERED TO A COMFORTABLE FOAM BACKING, CUT TO CUSTOM SIZES, MINIMUM JOINTS PER LOCATION, TO FIT AREAS SHOWN AND SCHEDULED. 2. ALL SETTING AND FLOOR LEVELING MATERIALS AND ANCHORAGE DEVICES USED FOR MAT SHALL BE COMPATIBLE TO THE SURFACES INSTALLED TO, EXISTING AND NEW, AS RECOMMENDED BY THE MAT MANUFACTURER. III EXECUTION - 1. PREPARE AND LEVEL FLOOR SURFACE CONDITIONS REQUIRED FOR FLUSH, SMOOTH, LEVEL MAT INSTALLATIONS. 2. MAT SHALL BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS. 3. AFTER MAT HAS BEEN INSTALLED AND CONTRACTOR HAS COMPLETED CLEANUP, THE CONTRACTOR SHALL PLACE HEAVY DUTY BUILDING PAPER OVER THE MAT, SECURED WITH (2) INCH MASKING TAPE, TO PROTECT THE MAT FROM DAMAGE. 4. PERFORM ALL WORK IN ACCORDANCE WITH SECTIONS 01045, 01400, 01600 AND 01710 OF THESE SPECIFICATIONS. END OF SECTION 12670 DRAWN DATE 12=1-08 CHECKED JOB NUMBER 0614 SPECIFICATIONS 0101_0__ SUMMARY OF WORK I WORK INCLUDED - 1 WORK INCLUDED: TENANT FIT OUT OF RETAIL SPACE, INCLUDING NEW PARTITIONS, ELECTRICAL, MECHANICAL & FINISHES AS FURTHER DEFINED IN THE CONTRACT DOCUMENTS. 2. ALL WORK TO BE CONDUCTED AS QUIETLY AS POSSIBLE AND WITH A MINIMUM AMOUNT OF NOISE OR DUST. 3. WHERE THE SCOPE OF THE WORK OF THE CONTRACTOR CALLS FOR SERVICE CONNECTIONS, SUPPORTS OR INSTALLATION OF ANY ITEM OR GROUP OF ITEMS BEING FURNISHED BY OTHER CONTRACTS, THE OMISSION OF ANY GIVEN ITEM FROM THE DRAWINGS OF THIS PARTICULAR CONTRACT SHALL NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY FOR INSTALLING, CONNECTING OR SUPPORTING SUCH ITEM AT NO INCREASE IN CONTRACT. 4. THE CONTRACTOR SHALL BE BOUND TO THE BUILDING RULES AS TO THE HOURS OF WORK, USE OF THE ELEVATORS AND STAIRS, STORAGE AND REMOVAL OF DEBRIS, ETC. ALL WORK SHALL BE PERFORMED AS EXPEDITIOUSLY AS POSSIBLE. THE CONTRACT PRICE MUST INCLUDE ANY AND ALL CONSIDERATION OF THE BUILDING RULES. NO EXTRA CHARGES WILL BE ADDED AFTER CONTRACT SIGNING. 5. THE CONTRACTOR AND SUBCONTRACTORS SHALL PERFORM THEIR WORK IN A MANNER THAT WILL CAUSE THE LEAST INTERFERENCE TO THE OPERATION OF THE PRESENT TENANTS AND TO THE PUBLIC. 6. SUBJECT TO THE CONDITIONS ELSEWHERE STATED HEREIN, THE AREAS TO BE OCCUPIED BY THE PERMANENT CONSTRUCTION WILL BE MADE AVAILABLE TO THE CONTRACTOR UPON THE COMMENCEMENT OF THE CONTRACTOR'S FIRST OPERATIONS AT THE CONSTRUCTION SITE. THE CONTRACTOR WILL PROVIDE PROTECTION OF COMMON AREAS AS NECESSARY, SUBJECT TO THE REVIEW AND THE ACCEPTANCE OF THE OWNER AND ARCHITECT. 7. THE CONTRACTOR SHALL COOPERATE WITH AND COORDINATE THEIR OPERATIONS WITH THOSE OF THE OWNER AND ALL TENANTS. THE CONTRACTOR SHALL SO PLAN AND CONDUCT THEIR OPERATIONS AS TO WORK IN HARMONY WITH OTHERS ENGAGED AT THE CONSTRUCTION SITE AND NOT TO DELAY, ENDANGER OR INTERFERE WITH THE OPERATIONS OF OTHERS (WHETHER OR NOT SPECIFICALLY MENTIONED ABOVE), ALL TO THE BEST INTERESTS OF THE OWNER AND THE PUBLIC AND AS MAY BE DIRECTED BY THE OWNER, TENANTS AND ARCHITECT. 8. THE CONTRACTOR SHALL NOT INTERFERE WITH GENERAL PUBLIC ACCESS AND EGRESS. INTRODUCTION OF MATERIALS AND ACCESS AND EGRESS OF THE WORKFORCE SHALL BE RESTRICTED TO SUCH PLACES AND IN SUCH MANNER AS ACCEPTED BY THE OWNER, TENANT AND ARCHITECT. 9. ALL WORK IS REQUIRED TO BE COORDINATED WITH TENANT OPERATIONS THROUGH THE ARCHITECT. THE CONTRACTOR WILL BE PERMITTED TO WORK DURING NORMAL WORKING HOURS ONLY TO THE EXTENT THAT SUCH OPERATION DOES NOT INTERFERE SIGNIFICANTLY WITH OPERATIONS. WORK WITHIN ANY AREA ENCLOSED BY PERMANENT CONSTRUCTION PARTITION WILL BE PERMITTED DURING ALL HOURS PROVIDED THAT NOISE LEVELS ARE ACCEPTABLE TO THE OWNER, TENANTS AND THE ARCHITECT. 10. PROVIDE SUCH EQUIPMENT AND FACILITIES AS ARE NECESSARY OR REQUIRED, IN CASE OF ACCIDENT, FOR FIRST AID SERVICE TO ANY WHO MAY BE INJURED IN THE PROGRESS OF THE WORK, AND HAVE STANDING ARRANGEMENTS FOR THE REMOVAL AND HOSPITAL TREATMENT OF ANY EMPLOYEES WHO MAY BE INJURED OR WHO MAY BECOME ILL. COMPLY WITH OCCUPATIONAL SAFETY AND HEALTH STANDARDS ISSUED BY THE SECRETARY OF LABOR PURSUANT TO THE WILLIAMS-STEIGER OCCUPATIONAL SAFETY AND HEALTH ACF OF 1970 AND AS AMENDED. 1 1 . WORK BY OWNER 1. THE OWNER MAY AWARD SEPARATE CONTRACTS WHICH WILL COMMENCE DURING WORK UNDER THIS CONTRACT. THESE CONTRACTS INCLUDE, BUT NOT NECESSARILY LIMITED TO: TELEPHONES, ELECTRONIC EQUIPMENT, WIRING, SIGNAL AND COMMUNICATION CIRCUITS. 2. ITEMS NOTED 'NIC' (NOT IN CONTRACT), WILL BE FURNISHED AND INSTALLED BY OWNER. 3. FOR ITEMS FURNISHED BY OWNER FOR FINAL CONNECTION BY CONTRACTOR. REFER TO DRAWINGS. 12. OWNER SUPPLIED PRODUCTS 1 . THE FOLLOWING ABBREVIATIONS ARE UTILIZED IN THE CONTRACT DOCUMENTS: A. OSOI - OWNER SUPPLIED OWNER INSTALLED. B OSCI - OWNER SUPPLIED CONTRACTOR INSTALLED. 2. OWNER'S RESPONSIBILITIES: (OSOI & OSCI) A. ARRANGE FOR AND DELIVER OWNER REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES, TO THE CONTRACTOR. B. ARRANGE AND PAY FOR PRODUCT DELIVERY TO SITE. C. ON DELIVERY, INSPECT PRODUCTS JOINTLY WII-H THE CONTRACTOR. D. SUBMIT CLAIMS FOR TRANSPORTATION DAMAGE AND REPLACE DAMAGED, DEFECTIVE, OR DEFICIENT ITEMS. E. ARRANGE FOR MANUFACTURERS' WARRANTIES, INSPECTIONS, AND SERVICE. 3. CONTRACTOR'S RESPONSIBILITIES: (OSOI & OSCI) A. REVIEW OWNER REVIEWED SHOP DRAWINGS, PRODUCT DATA, AND SAMPLES. B. RECEIVE, UNLOAD AND UNCRATE PRODUCTS AT THE SITE; INSPECT FOR COMPLETENESS OR DAMAGE, JOINTLY WITH OWNER. C. HANDLE AND STORE PRODUCTS. D. REPAIR OR REPLACE ITEMS DAMAGED AFTER RECEIPT. E. INSTALL AND FINISH PRODUCTS. (USCI ONLY) 4. ITEMS SUPPLIED TO SITE AND INSTALLED BY OWNER (OSOI): A. ITEMS AS INDICATED ON THE DRAWINGS. 5. ITEMS SUPPLIED BY OWNER FOR INSTALLATION BY CONTRACTOR (OSCI): A. ITEMS AS INDICATED ON THE DRAWINGS. II MATERIALS -NOT USED III EXECUTION - NOT USED END OF SECTION 0 10 10 010.19,-_(:QNTRALT U` IDERATIQN_ I WORK INCLUDED - 1. ACCEPTED ALTERNATES WILL BE IDENTIFIED IN OWNER -CONTRACTOR AGREEMENT. COORDINATE RELATED WORK AND MODIFY SURROUNDING WORK AS REQUIRED. 2. CONTRACTOR SHALL SUBMIT A PRINTED SCHEDULE OF VALUES ON AIA FORM G703 - APPLICATION AND CERTIFICATE FOR PAYMENT CONTINUATION SHEET, IN DUPLICATE, WITHIN 15 DAYS AFTER DATE OF OWNER -CONTRACTOR AGREEMENT. 3. CONTRACTOR SHALL SUBMIT THREE COPIES OF EACH APPLICATION FOR PAYMENT TO THE ARCHITECT ON AIA FORM G702 - APPLICATION AND CERTIFICATE FOR PAYMENT AND AIA G703 - CONTINUATION SHEET, UTILIZING SCHEDULE OF VALUES. 4. CHANGE PROCEDURES: 'I . THE ARCHITECT WILL ADVISE OF MINOR CHANGES IN THE WORK NOT INVOLVING AN ADJUSTMENT TO CONTRACT SUM OR CONTRACT TIME AS AUTHORIZED BY AIA A201, BY ISSUING SUPPLEMENTAL INSTRUCTIONS ON AIA FORM G710. 2. THE ARCHITECT MAY ISSUE A PROPOSAL REQUEST WHICH INCLUDES A DETAILED DESCRIPTION OF A PROPOSED CHANGE WITH SUPPLEMENTARY OR REVISED CONTRACT DOCUMENTS, A CHANCE IN CONTRACT TIME FOR EXECUTING THE CHANGE, WITH A STIPULATION OF ANY OVERTIME WORK REQUIRED AND THE PERIOD OF TIME DURING WHICH THE REQUESTED PRICE WILL BE CONSIDERED VALID. CONTRACTOR TO SUBMIT AN ESTIMATE WITHIN SEVEN CALENDAR DAYS. 3. THE CONTRACTOR MAY PROPOSE CHANGES BY SUBMITTING A REQUEST FOR CHANGE TO THE ARCHITECT, DESCRIBING THE PROPOSED CHANGE AND ITS FULL EFFECT ON THE WORK. INCLUDE A STATEMENT DESCRIBING THE REASON FOR THE CHANGE, AND THE EFFECT ON THE CONTRACT SUM AND CONTRACT TIME WITH FULL DOCUMENTATION AND A STATEMENT DESCRIBING THE EFFECT ON WORK BY SEPARATE OR OTHER CONTRACTORS. 4. THE ARCHITECT MAY ISSUE AIA FORM G713 CONSTRUCTION CHANGE DIRECTIVE, SIGNED BY THE OWNER, INSTRUCTING THE CONTRACTOR TO PROCEED WITH A CHANGE IN THE WORK, FOR SUBSEQUENT INCLUSION IN A CHANGE ORDER. DOCUMENT WILL DESCRIBE CHANGES IN THE WORK, AND DESIGNATE METHOD OF DETERMINING ANY CHANGE IN CONTRACT SUM OR CONTRACT TIME. CONTRACTOR SHALL PROMPTLY EXECUTE THE CHANGE. 5. TIME AND MATERIAL CHANGE ORDER: THE CONTRACTOR SHALL SUBMIT AN ITEMIZED ACCOUNT AND SUPPORTING DATA AFTER COMPLETION OF CHANGE, WITHIN TIME LIMITS INDICATED IN THE CONDITIONS OF THE CONTRACT. ARCHITECT WILL DETERMINE THE CHANGE ALLOWABLE IN CONTRACT SUM AND CONTRACT TIME AS PROVIDED IN THE CONTRACT DOCUMENTS. MAINTAIN DETAILED RECORDS OF WORK DONE ON TIME AND MATERIAL BASIS. PROVIDE FULL INFORMATION REQUIRED FOR EVALUATION OF PROPOSED CHANGES, AND TO SUBSTANTIATE COSTS FOR CHANGES IN THE WORK. 6. CONTRACTOR SHALL ISSUE CHANGE ORDERS, USING AIA G701 CHANGE ORDER, FOR SIGNATURES OF ALL PARTIES AS PROVIDED IN THE CONDITIONS OF THE CONTRACT. II MATERIALS - NOT USED III EXECUTION - NOT USED END OF SECTION 01019 O> a9_- COQRDINATION_AN MEETING S I WORK INCLUDED - I . VERIFY THAT UTILITY REQUIREMENTS AND CHARACTERISTICS OF OPERATING EQUIPMENT ARE COMPATIBLE WITH BUILDING UTILITIES. COORDINATE WORK OF VARIOUS SECTIONS HAVING INTERDEPENDENT RESPONSIBILITIES FOR INSTALLING, CONNECTING TO, AND PLACING IN SERVICE, SUCH EQUIPMENT. 2. COORDINATE SPACE REQUIREMENTS AND INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WHICH ARE INDICATED DIAGRAMMATICALLY ON DRAWINGS. FOLLOW ROUTING SHOWN FOR PIPES, DUCTS, AND CONDUIT, AS CLOSELY AS PRACTICABLE. PLACE RUNS PARALLEL WITH LINE OF BUILDING. UTILIZE SPACES EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR OTHER INSTALLATIONS, FOR MAINTENANCE, AND FOR REPAIR. 3. IN FINISHED AREAS EXCEPT AS OTHERWISE INDICATED, CONCEAL PIPES, DUCTS, AND WIRING WITHIN THE CONSTRUCTION. COORDINATE LOCATIONS OF FIXTURES AND OUTLETS WITH FINISH ELEMENTS. 4. AFTER OWNER OCCUPANCY OF PREMISES, ACCESS TO SPACE FOR CORRECTION OF DEFECTIVE WORK AND WORK NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS (PUNCH LIST ITEMS), SHALL BE CONDUCTED AT TIMES OTHER THAN REGULAR WORKING HOURS UNLESS OTHERWISE CONSENTED TO BY THE OWNER. 5. PRE -CONSTRUCTION MEETING A. A PRE -CONSTRUCTION MEETING WILL BE SCHEDULED AT THE PROJECT SITE PRIOR TO CONTRACTOR OCCUPANCY. B. ATTENDANCE REQUIRED: AUTHORITY HAVING JURISDICTION, LANDLORD, OWNER, ARCHITECT, CONTRACTOR AND CONTRACTOR'S SUPERINTENDENT. C. AGENDA: 1. USE OF PREMISES BY OWNER AND CONTRACTOR. 2. SECURITY 3. TEMPORARY PROTECTION AND SAFETY 4. DUST AND NOISE PROTECTION 5. STAGING AREA, DELIVERY AND STORAGE OF MATERIALS 6. SCHEDULES AND PHASING OF THE WORK 7. CONTRACTOR PARKING 8. WORK HOURS 9. INSPECTION AND CERTIFICATE OF OCCUPANCY PROCEDURES 10. ANY SPECIFIC REQUIREMENTS BY AUTHORITY HAVING JURISDICTION, LANDLORD OR OWNER. D. CONTRACTOR SHALL RECORD MINUTES AND DISTRIBUTE COPIES WITHIN TWO BUSINESS DAYS AFTER MEETING TO PARTICIPANTS, WITH ONE COPY TO THE AUTHORITY HAVING JURISDICTION, LANDLORD, OWNER, ARCHITECT, ALL OTHER PARTICIPANTS AND THOSE AFFECTED BY DECISIONS MADE. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 6. SITE MOBILIZATION MEETING A. ARCHITECT AND OWNER WILL SCHEDULE A MEETING AT THE PROJECT SITE PRIOR TO CONTRACTOR OCCUPANCY. B. ATTENDANCE REQUIRED: OWNER, ARCHITECT, SPECIAL CONSULTANTS, CONTRACTOR, CONTRACTOR'S SUPERINTENDENT, AND MAJOR SUBCONTRACTORS. C. AGENDA: 1. USE OF PREMISES BY OWNER AND CONTRACTOR. 2. OWNER'S REQUIREMENTS. 3. CONSTRUCTION FACILITIES AND CONTROLS PROVIDED BY OWNER. 4. TEMPORARY FACILITIES PROVIDED BY OWNER. 5. SECURITY AND HOUSEKEEPING PROCEDURES. 6. SCHEDULES. 7. PROCEDURES FOR TESTING. 8. PROCEDURES FOR MAINTAINING RECORD DOCUMENTS. 9. REQUIREMENTS FOR START-UP OF EQUIPMENT. 10. INSPECTION AND ACCEPTANCE OF EQUIPMENT PUT INTO SERVICE DURING CONSTRUCTION PERIOD. D. CONTRACTOR SHALL RECORD MINUTES AND DISTRIBUTE COPIES WITHIN TWO BUSINESS DAYS AFTER MEETING TO PARTICIPANTS, WITH ONE COPY TO OWNER, ARCHITECT, OTHER PARTICIPANTS, AND THOSE AFFECTED BY DECISIONS MADE. PROGRESS MEETINGS A. CONTRACT OR SHALL SCHEDULE AND ADMINISTER MEETINGS THROUGHOUT PROGRESS OF THE WORK AT MAXIMUM WEEKLY INTERVALS. B. CONTRACTOR SHALL MAKE ARRANGEMENTS FOR MEETINGS, PREPARE AGENDA WITH COPIES FOR PARTICIPANTS, PRESIDE AT MEETINGS. 7. C. ATTENDANCE REQUIRED: JOB SUPERINTENDENT, MAJOR SUBCONTRACTORS AND SUPPLIERS, OWNER, ARCHITECT, AND CONSULTANTS APPROPRIATE "1-0 AGENDA TOPICS FOR EACH MEETING. III D. AGENDA: 1. REVIEW MINUTES OF PREVIOUS MEETING. 2. REVIEW PROGRESS OF WORK. 3. FIELD OBSERVATIONS, PROBLEMS, AND DECISIONS. 4. IDENTIFICATION OF PROBLEMS WHICH IMPEDE PLANNED PROGRESS. 5. REVIEW OF SUBMITTALS SCHEDULE AND STATUS OF SUBMITTALS. 6. REVIEW OF OFF-SITE FABRICATION AND DELIVERY SCHEDULES. 7. MAINTENANCE OF PROGRESS SCHEDULE. 8. CORRECTIVE MEASURES TO REGAIN PROJECTED SCHEDULES. 9. PLANNED PROGRESS DURING SUCCEEDING WORK PERIOD. 10. COORDINATION OF PROJECTED PROGRESS. 1 1 . MAINTENANCE OF QUALITY AND WORK STANDARDS. 12. EFFECT OF PROPOSED CHANGES ON PROGRESS SCHEDULE AND COORDINATION. 13. OTHER BUSINESS RELATING TO WORK. E. CONTRACTOR SHALL RECORD MINUTES AND DISTRIBUTE COPIES WITHIN TWO BUSINESS DAYS AFTER MEETING TO PARTICIPANTS, WITH ONE COPY TO ARCHITECT, OWNER, PARTICIPANTS, AND THOSE AFFECTED BY DECISIONS MADE. PRE -INSTALLATION MEETING A. WHEN REQUIRED IN INDIVIDUAL SPECIFICATION SECTIONS, CONVENE A PRE -INSTALLATION MEETING AT WORK SITE PRIOR TO COMMENCING WORK OF THE SECTION. B. REQUIRE ATTENDANCE OF PARTIES DIRECTLY AFFECTING, OR AFFECTED BY, WORK OF THE SPECIFIC SECTION. 8. C. NOTIFY ARCHITECT FOUR BUSINESS DAYS IN ADVANCE OF MEETING DATE. D. CONTRACTOR SHALL PREPARE AGENDA AND PRESIDE AT MEETING: 1 . REVIEW CONDITIONS OF INSTALLATION, PREPARATION AND INSTALLATION PROCEDURES. 2. REVIEW COORDINATION WITH RELATED WORK. E. CONTRACTOR SHALL RECORD MINUTES AND DISTRIBUTE COPIES WITHIN TWO BUSINESS DAYS AFTER MEETING TO PARTICIPANTS, WITH ONE COPY TO ARCHITECT, OWNER, PARTICIPANTS, AND THOSE AFFECTED BY DECISIONS MADE. II MATERIALS - NOT USED III EXECUTION - NOT USED END OF SECTION 01039 Q1045 CUTIM. AND,PAZCH NO; I WORK INCLUDED - 1. THIS SECTION ESTABLISHES GENERAL REQUIREMENTS PERTAINING TO CUTTING INCLUDING FITTING, AND PATCHING OF ALL THE WORK, INCLUDING MISCELLANEOUS ARCHITECTURAL, STRUCTURAL MECHANICAL AND ELECTRICAL WORK REQUIRED OUTSIDE THE CONTRACT LIMIT LINE REQUIRED TO: 1. MAKE THE SEVERAL PARTS FIT PROPERLY, NEW AND EXISTING. 2. CORE DRILL FLOOR STRUCTURE AND SAWCUT FINISH FLOOR TOPPING FOR ELECTRICAL AND NEW FINISH FLOOR REQUIREMENTS. 3. UNCOVER WORK TO PROVIDE FOR THE INSTALLATION, INSPECTION, OR BOTH OF ILL-TIMED WORK. 4. REMOVE AND REPLACE WORK NOT CONFORMING TO REQUIREMENTS OF THE CONTRACT DOCUMENTS. S. REMOVE AND REPLACE DEFECTIVE WORK. 6. CUT, REPAIR AND PATCH TO MATCH EXISTING WORK LEFT EXPOSED TO VIEW BY REMOVALS AND WHERE DAMAGED BY THIS CONTRACT WORK. NO. I DATE I REVISION 2. IN ADDITION TO OTHER REQUIREMENTS SPECIFIED, UPON THE ARCHITECT'S REQUEST, UNCOVER WORK TO PROVIDE FOR INSPECTION BY THE ARCHITECT OF COVERED WORK, AND REMOVE SAMPLES OF INSTALLED MATERIALS FOR TESTING. D. DO NOT CUT OR ALTER WORK PERFORMED UNDER SEPARATE CONTRACT WITHOUT THE ARCHITECT'S WRITTEN PERMISSION. 4. PERFORM ALL CUTTING AND PATCHING IN STRICT ACCORDANCE WITH PERTINENT REQUIREMENTS OF THESE SPECIFICATIONS AND, IN THE EVENT THAT NO SUCH REQUIREMENTS ARE DETERMINED, IN CONFORMANCE WITH THE ARCHITECT'S WRITTEN DIRECTION. 5. PRIOR TO CUTTING WHICH AFFECTS THE STRUCTURAL SAFETY OR THE STRUCTURAL INTEGRITY OF THE BUILDING, SUBMIT A WRITTEN REQUEST TO THE ARCHITECT FOR PERMISSION TO PROCEED WITH CUTTING. DO NOT CUT ANY STRUCTURAL WALLS, SLABS OR FRAMING MEMBERS, INCLUDING ANY REINFORCING UNTIL PERMISSION IS RECEIVED IN WRITING. IF REINFORCEMENT IS ENCOUNTERED WHERE NOT EXPECTED DO NOT PROCEED WITH CUTTING WITHOUT NOTIFYING THE ARCHITECT AND RECEIVING WRITTEN PERMISSION TO PROCEED. 6. PRIOR TO CUTTING AND PATCHING PERFORMED PURSUANT TO THE ARCHITECT'S INSTRUCTIONS, SUBMIT COST ESTIMATE TO THE ARCHITECT. SECURE THE ARCHITECT'S ACCEPTANCE OF COST ESTIMATE AND TYPE OF COST REIMBURSEMENT BEFORE PROCEEDING WITH CUTTING AND PATCHING. 7. SUBMIT WRITTEN NOTICE TO THE ARCHITECT DESIGNATING TIME THE WORK WILL BE UNCOVERED, TO PROVIDE FOR THE ARCHITECT'S OBSERVATION. MATERIALS - 1 . FOR REPLACEMENT OF WORK REMOVED, USE MATERIALS WHICH COMPLY WITH THE PERTINENT SECTIONS OF THESE SPECIFICATIONS. EXISTING AREAS ABUTTING NEW WORK OUTSIDE CONTRACT LIMIT LINE ARE TO MATCH EXISTING LIKE WORK IN MATERIAL AND FINISH: SEE SECTION 01400. EXECUTION - 1 . INSPECT EXISTING CONDITIONS, INCLUDING ELEMENTS SUBJECT TO MOVEMENT OR DAMAGE DURING CUTTING AND PATCHING. 2. AFTER UNCOVERING THE WORK, INSPECT CONDITIONS AFFECTING INSTALLATION OFTHE NEW WORK. 3. IF UNCOVERED CONDITIONS ARE NOT AS ANTICIPATED, IMMEDIATELY NOTIFY THE ARCHITECT AND SECURE NEEDED DIRECTIONS. 4. DO NOT PROCEED IN AREAS OF DISCREPANCY UNTIL ALL SUCH DISCREPANCIES HAVE BEEN TRULY RESOLVED. 5. PROVIDE ALL REQUIRED PROTECTION INCLUDING, BUT NOT NECESSARILY LIMITED TO, SHORING, BRACING AND SUPPORT TO MAINTAIN STRUCTURAL INTEGRITY OF THE WORK, 6. PERFORM ALL WORK AS REQUIRED UNDER PERTINENT SECTIONS OF THESE SPECIFICATIONS. PERFORM CUTTING AND PATCHING BY METHODS WHICH WILL PREVENT- DAMAGE TO OTHER PORTIONS OF THE WORK AND WILL PROVIDE PROPER SURFACES TO RECEIVE OR REPAIR NEW WORK. PERFORM FITTING AND ADJUSTMENT OF PRODUCTS TO PROVIDE FINISHED INSTALLATION COMPLYING WITH THE SPECIFIED TOLERANCES AND FINISHES. 7. CORE DRILL SLAB AND MAKE MINIMUM WIDTH AND RUN SAWCUT IN FINISH FLOOR TOPPING TO FLUSH FLOOR BOX LOCATIONS. ADJUST CORE DRILLING TO MISS SLAB REINFORCEMENT. PATCH TO MATCH FINISH FLOOR WHERE EXPOSED TO VIEW. END OF SECTION 0104.5 01.0 0. -, FERN -L E STANDARDS I WORK INCLUDED - '1 . THROUGHOUT'THE CONTRACT DOCUMENTS, REFERENCE IS MADE TO CODES AND STANDARDS WHICH ESTABLISH QUALITIES AND TYPES OF WORKMANSHIP AND MATERIALS, AND WHICH ESTABLISH METHODS FOR "TESTING AND REPORTING ON THE PERTINENT CHARACTERISTICS. 2. ALL MATERIALS AND WORKMANSHIP ARE REQUIRED BY THESE CONTRACT DOCUMENTS TO MEET OR EXCEED ALL PERTINENT CODES AND STANDARDS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND WORKMANSHIP WHICH MEET OR EXCEED THE SPECIFICALLY NAMED CODE OR STANDARD. 3. IT IS ALSO THE CONTRACTOR'S RESPONSIBILITY, WHEN SO REQUIRED BY THE CONTRACT DOCUMENTS OR BY WRITTEN REQUEST FROM THE ARCHITECT, TO DELIVER TO THE ARCHITECT ALL REQUIRED PROOF THAT THE MATERIALS AND WORKMANSHIP, OR BOTH, MEET OR EXCEED THE REQUIREMENTS OF A SPECIFICALLY NAMED CODE OR STANDARD. SUCH PROOF SHALL BE IN THE FORM REQUESTED IN WRITING BY THE ARCHITECT, AND GENERALLY WILL BE REQUIRED TO BE COPIES OF A CERTIFIED REPORT OF TESTS CONDUCTED BY A TESTING AGENCY ACCEPTED FOR THAT PURPOSE BY THE ARCHITECT 4. SPECIFIC NAMING OF CODES OR STANDARDS OCCURS ON THE DRAWINGS AND IN OTHER SECTIONS OF THESE SPECIFICATIONS. 5. QUALITY ASSURANCE: 1. FAMILIARITY WITH PERTINENT CODES AND STANDARDS. 2. IN PROCURING ALL ITEMS USED IN THIS WORK, IT IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY THE DETAILED REQUIREMENTS OF THE SPECIFICALLY NAMED CODES AND STANDARDS ANDTO VERIFY THATTHE ITEMS PROCURED FOR USE IN THIS WORK MEET OR EXCEED THE SPECIFIED REQUIREMENTS. 3. THE ARCHITECT RESERVES THE RIGHT TO REJECT ITEMS INCORPORATED INTO THE WORK WHICH FAIL TO MEET THE SPECIFIED MINIMUM REQUIREMENTS. THE ARCHITECT FURTHER RESERVES THE RIGHT, AND WITHOUT PREJUDICE TO OTHER RECOURSE THE ARCHITECT MAY TAKE, TO ACCEPT NON -COMPLYING ITEMS SUBJECT TO AN ADJUSTMENT IN THE CONTRACT AMOUNT AS ACCEPTED BY THE ARCHITECT AND THE OWNER. II MATERIALS - 1. REFERENCE STANDARDS: 1. REFERENCE STANDARDS LISTED IN THESE SPECIFICATIONS INCLUDE, BIJT ARE NOT NECESSARILY LIMITED TO, THE LATEST EDITIONS OF STANDARDS PROMULGATED BY THE FOLLOWING AGENCIES AND ORGANIZATIONS: AAMA AMERICAN ARCHITECTURAL MANUFACTURER'S ASSOCIATION 2700 RIVER ROAD, SUITE 1 18, DES PLAINS, IL (31 2) 699-7310 ACT AMERICAN CONCRETE INSTITUTE P.O. BOX 19150 REDFOLD STATION DETROIT, MI 48219 AIA AMERICAN INSTITUTE OF ARCHITECTS 1735 NEW YORK AVE. NW, WASHINGTON, DC 20006 (202) 626-7474 AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION 400 N. MICHIGAN AVE. 8TH FLR., CHICAGO, IL 60611 (312) 670-2400 AISI AMERICAN IRON AND STEEL INSTITUTE 1000 1 6TH ST. NW, WASHINGTON, DC 20036 (202) 452-7100 AITC AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 333 W. HAMPDEN AVE. ENGLEWOOD, CO 80110 (303) 76'1-3212 ALSC AMERICAN LUMBER STANDARDS COMMITTEE P.O. BOX 210, GERMANTOWN, MD 20874 (301) 972-1700 AMCA AIR MOVEMENT AND CONTROL ASSOCIATION 30 W. UNIVERSITY DRIVE, ARLINGTON HEIGHTS, IL 60004 (312) 394-0-150 ANSI AMERICAN NATIONAL STANDARDS INSTITUTE '1430 BROADWAY, NEW YORK, NY '10018 (2'12) 354-3300 APA AMERICAN PLYWOOD ASSOCIATION P.O. BOX -11 70, TACOMA, WA 9841 -1 (206) 565-6600 ARI AIR CONDITIONING AND REFRIGERATION INSTITUTE 1 501 WILSON BLVD., ARLINGTON, VA 22209 (703) 524-8800 ASC ADHESIVE AND SEALANT COUNCIL '1600 WILSON BLVD., SUITE 910, ARLINGTON, VA 22209 (703) 841-1112 ASHRAE AMERICAN SOCIETY OF HEATING, REFRIGERATING AND AIRCONDITIONING ENGINEERS '1791 TULLIE CIRCLE, NE, ATLANTA, GA 30329 (404) 636-8400 ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS 345 E. 47TH ST., NEW YORK, NY 1001 7 (2 -12) 705-7722 ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS 15233 VENTURA BLVD., SUITE 81 1 , SHERMAN OAKS, CA 91403 (21 3) 783-4845 ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS 1916 RACE ST., PHILADELPHIA, PA 19103 (21 5) 299-5400 AWI AMERICAN WOODWORK INSTITUTE 1952 ISAAC NEWTON SQUARE, RESTON, VA 20190 (703) 733-0600 AWPA AMERICAN WOOD PRESERVERS ASSOCIATION 7735 OLD GEORGETOWN RD. BETHESDA, MD 20014 AWS AMERICAN WELDING SOCIETY P.O. BOX 351040, 550 LEJUNE RD., NW, MIAMI, FL 33135 (305) 443-9353 AWWA AMERICAN WATER WORKS ASSOCIATION, INC. 6666 W. QUINCY AVE., DENVER, CO 80235 (303) 794-7711 BOCA BASIC NATIONAL BUILDING CODE BUILDING OFFICIALS AND CODE ADMINISTRATIONS INTER. INC. 4051 W. FLOSSMOOR RD., COUNTRY CLUB HILLS, IL 60477-5795 (708) 799-2300 BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION 60 E. 42ND ST., ROOM 511, NEW YORK, NY 10"165 (212) 682-8142 FGMA FLAT GLASS MARKETING ASSOCIATION 3310 HARRISON ST., TOPEKA, KS 6661 1 (913) 266-7013 IEEE INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS, INC. 345 E. 47-FFI ST., NEW YORK, NY 1001 7 (21 2) 705-7900 MCAA MECHANICAL CONTRACTOR'S ASSOCIATION OF AMERICA 5530 WISCONSIN ANE., SUITE 250, CHEVY CHASE, MD 20815 (301) 654-7960 NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS 221 N, LASALLE ST., CHICAGO, IL 60601 (312) 346-1600 N B S NATIONAL BUREAU OF STANDARDS -U.S. DEPARTMENT OF COMMERCE GAITHERSBURG, MD 20234 (301) 921-1000 NEC NATIONAL ELECTRICAL CODE-NFPA BATTERYMARCH PARK, QUINCY, MA 02269 (617) 770-3300 NECA NATIONAL ELECTRICAL CONTRACTORS ASSOCIATION 7315 WISCONSIN AVE., BETHESDA, MD 20814 (301) 657-3110 Hudson News - Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA NEMA NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION 2'101 L ST., NW, WASHINGTON, DC 20037 (202) 457-8400 NFPA NATIONAL FIRE PROTECTION ASSOCIATION BATTERYMARCH PARK, QUINCY, MA 02269 (617) 770-3300 NHLA NATIONAL HARDWARE LUMBER ASSOCIATION P.O. BOX 34518, MEMPHIS, TN 38104 (90'1) 377-1818 NMC NATIONAL MECHANICAL CODE-BOCA 4051 W. FLOSSMOOR RD., COUNTRY CLUB HILLS, IL 60477-5795 (708)799-2300 NPC NATIONAL PLUMBING CODE-BOCA 4051 W. FLOSSMOOR RD., COUNTRY CLUB HILLS, IL 60477-5795 (708) 799-2300 OSHA OCCUPATIONAL SAFETY HEALTH ADMINISTRATION U.S. DEPARTMENT OF LABOR WASHINGTON, DC 20402 SMACNA SHEET METAL AND AIR CONDITIONING CONTRACTORS NATIONAL ASSOCIATION P.O. BOX 70, MERRIFIELD,VA 22-116 (703) 790-9890 SSPC STEEL STRUCTURES PAINTING COUNCIL 4400 5TH AVE„ PITTSBURGH, PA 152"13 (412) 578-3327 TCA TILE COUNCIL OF AMERICA, INC. P.O. BOX 326; PRINCETON, NJ 08540 (609) 921-7050 UL UNDERWRITER'S LABORATORIES 333 PFINGSTEN RD., NORTHBROOK, IL 60062 (31 2) 272-8800 III EXECUTION - NOT USED END OF SECTION 01090 12 DRAWN DATE '12-1-08 CHECKED JOB NUMBER 0814 GENERAL SPECIFICATIONS 0'1 S00 Sl_1BMLfFALS AND...SUB-,TITl1TIQNS: I WORK INCLUDED - 1. SUBMS C� DRAW I yGS ON ALL FABRICATED ff-EM a. 2. SUBMIT SAMPLES -QF ALLMSH MATERIALS. 3. SUBMIT MANUFACTURER'S LITERATURE ON ALL MATERIALS NOT INCLUDED IN THE SHOP DRAWING OR SAMPLE SUBMITTALS. 4. SUBMIT ALL ADDITIONAL REQUIREMENTS AS SPECIFIED ON THE DRAWINGS INCLUDING STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS. S. PROVIDE ON-SITE OR SHOP MOCK-UPS WHERE REQUESTED BY THE ARCHITECT. MOCK-UPS ACCEPTED BY THE ARCHITECT MAY REMAIN IN PLACE OR BE USED AS THE FINISH PRODUCT. 6. SUBMIT CONSTRUCTION SCHEDULE AND A SUBMITTALS SCHEDULE IN COORDINATION WITH THE PHASING OF THE WORK. 7. PRIOR TO EACH SUBMITTAL, CAREFULLY REVIEW AND COORDINATE ALL ASPECTS OF EACH ITEM BEING SUBMITTED TO VERIFY THAT EACH 'ITEM AND THE SUBMITTAL FOR IT CONFORMS IN ALL RESPECTS WITH THE REQUIREMENTS OF THE CONTRACT DOCUMENTS. BY AFFIXING THE CONTRACTOR'S SIGNATURE TO EACH SUBMITTAL, CERTIFY THAT THIS COORDINATION HAS BEEN PERFORMED. 8. CERTIFY THAT ALL MATERIAL USED IN THE WORK COMPLY WITH ALL SPECIFIED PROVISIONS THEREOF. CERTIFICATION SHALL NOT BE CONSTRUED AS RELIEVING THE CONTRACTOR FROM FURNISHING SATISFACTORY MATERIALS IF, AFTER TESTS ARE PERFORMED ON SELECTED SAMPLES, THE MATERIAL IS FOUND TO NOT MEET SPECIFIED REQUIREMENTS. 9. SHOW ON EACH CERTIFICATION THE NAME AND LOCATION OF THE WORK, THE NAME AND ADDRESS OF THE SUB -CONTRACTOR, QUANTITY AND DATE OR DATES OF SHIPMENT OR DELIVERY TO WHICH THE CERTIFICATE APPLIES, AND NAME OF THE MANUFACTURING OR FABRICATING COMPANY. CERTIFICATION SHALL BE IN THE FORM OF A LETTER OR COMPANY STANDARD FORMS CONTAINING ALL REQUIRED DATA. CERTIFICATES SHALL BE SIGNED BY AN OFFICER OF THE MANUFACTURING OF FABRICATING COMPANY. II MATERIALS - 1. SUBMIT ALL SHOP DRAWINGS IN THE FORM OF,(1) SEPIA "TRANSPARENCY AND (2) BLIJELINE PRINTS OF EACH DRAWING. ALL REVIEW COMMENTS WILL BE SHOWN ON THE SEPIA TRANSPARENCY AND RETURNED TO THE CONTRACTOR. THE CONTRACTOR SHALL MAKE AND DISTRIBUTE ALL PRINTS REQUIRED FOR THEIR PURPOSES. 2. SUBMIT ALL SAMPLES IN THE QUANTITY WHICH ARE REQUIRED TO BE RETURNED PLUS (2) WHICH WILL BE RETAINED BY THE ARCHITECT. 3. SUBMIT THE NUMBER OF MANUFACTURER'S LITERATURE COPIES WHICH ARE REQUIRED TO BE RETURNED PLUS (2) COPIES WHICH WILL BE RETAINED BY THE ARCHITECT. 4. NOTIFY ARCHITECT IN ADVANCE FOR ON-SITE OR SHOP MOCK-UP REVIEW VISITS. SUBMIT CONSTRUCTION SCHEDULE AND SUBMITTALS SCHEDULE IN TYPE AND S. QUANTITIES TO BE DETERMINED AT THE PRE -CONSTRUCTION MEETING. 6. DO NOT SUBSTITUTE MATERIALS, EQUIPMENT, OR METHODS UNLESS SUCH SUBSTITUTION HAS BEEN SPECIFICALLY ACCEPTED, IN WRITING, FOR THIS WORK BY THE ARCHITECT. WHERE THE PHRASE "OR EQUAL" OR "OR EQUAL AS ACCEPTED BY THE ARCHITECT" OCCURS IN THE CONTRACT DOCUMENTS, DO NOT ASSUME THAT MATERIALS, EQUIPMENT, OR METHODS WILL BE ACCEPTED AS EQUAL UNLESS THE ITEM HAS BEEN SPECIFICALLY ACCEPTED FOR THIS WORK BY THE ARCHITECT. THE DECISION OF THE ARCHITECT SHALL BE FINAL. III EXECUTION - 1. CONSECUTIVELY NUMBER ALL SUBMITTALS. ACCOMPANY EACH SUBMITTAL WITH A LETTER OF TRANSMITTAL CONTAINING ALL PERTINENT INFORMATION REQUIRED FOR IDENTIFICATION AND REVIEWING OF THE SUBMITTAL. 2. MAKE ALL SHOP DRAWINGS ACCURATELY TO SCALE, SUFFICIENTLY LARGE TO SHOW ALL PERTINENT METHODS AND MATERIALS OF CONSTRUCTION. INDICATE ALL ADJACENT AND ABUTTING MATERIALS, NEW AND EXISTING. FULLY COORDINATE ALL CONDITIONS AND DIMENSIONS IN THE FIELD. COORDINATE WITH ALL OTHER TRADES INVOLVED. NOTE SUBCONTRACTOR OF OTHER TRADES INDICATED; DO NOT USE THE TERM, "BY OTHERS". 3. MAKE ALL SUBMITTALS IN GROUPS CONTAINING ALL ASSOCIATED ITEMS. PARTIAL SUBMITTALS MAY BE REJECTED. END OF SECTION 01 300 01 310 CONSTRUCTIONSCEDULE: I WORK INCLUDED - 1. TO ASSURE ADEQUATE PLANNING AND EXECUTION OF THE WORK, SO THAT THE WORK IS COMPLETED WITHIN THE NUMBER OF CALENDAR DAYS ALLOWED IN THE CONTRACT, AND TO ASSIST THE ARCHITECT IN APPRAISING THE REASONABLENESS OF THE PROPOSED SCHEDULE AND IN EVALUATING PROGRESS OF THE WORK, PREPARE AND MAINTAIN THE SCHEDULES AND REPORTS DESCRIBED IN THIS SECTION. 2. "DAY" USED THROUGHOUT THE CONTRACT, UNLESS OTHERWISE STATED, MEANS "CALENDAR DAY". 3. COORDINATE ALL WORK AND SCHEDULING WITH THE OWNER, AND THEIR USE OF THE SITE: 1. PHASING OF THE WORK 2. SECURITY 3. TEMPORARY PROTECTION AND SAFETY 4. STAGING AREA, DELIVERY AND STORAGE OF MATERIALS 5. DUST AND NOISE PROTECTION 6. CONTRACTOR'S PARKING AREA 4. QUALITY ASSURANCE: 1 . THE CONSTRUCTION SCHEDULE AS ACCEPTED BY THE ARCHITECT WILL BE AN INTEGRAL PART OF THE CONTRACT, AND WILL ESTABLISH INTERIM CONTRACT COMPLETION DATES FOR THE VARIOUS ACTIVITIES. 2. SHOULD ANY ACTIVITY NOT BE COMPLETED WITHIN 7 DAYS AFTER DATED SCHEDULE DATE, THE ARCHITECT SHALL HAVE THE RIGHT TO ORDER THE CONTRACTOR TO EXPEDITE COMPLETION OF THE ACTIVITY BY WHATEVER MEANS THE ARCHITECT DEEMS APPROPRIATE AND NECESSARY, WITHOUT ADDITIONAL COMPENSATION TO THE CONTRACTOR. 3. SHOULD ANY ACTIVITY BE 14 OR MORE DAYS BEHIND SCHEDULE THE ARCHITECT SHALL HAVE THE RIGHT TO PERFORM THE ACTIVITY OR HAVE THE ACTIVITY PERFORMED BY WHATEVER METHOD THE ARCHITECT DEEMS APPROPRIATE 4. COSTS INCURRED BY THE ARCHITECT IN CONNECTION WITH EXPEDITING CONSTRUCTION ACTIVITY UNDER THIS ARTICLE SHALL BE REIMBURSED TO THE ARCHITECT BY THE CONTRACTOR. IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT FAILURE BY THE ARCHITECT TO EXERCISE THE OPTION TO EITHER ORDER THE CONTRACTOR TO EXPEDITE AN ACTIVITY BY OTHER MEANS SHALL NOT BE CONSIDERED PRECEDENT SETTING FOR ANY OTHER ACTIVITIES. 5. SUBMITTALS: 1. COMPLY WITH PROVISIONS OF SECTION 01300. 2. WITHIN 7 DAYS AFTER RECEIPT OF NOTICE TO PROCEED, SUBMIT THREE COPIES OF A PRELIMINARY CONSTRUCTION SCHEDULE, PLUS THREE COPIES OF PROPOSED FORMAT FOR MATERIALS STATUS REPORTS, PREPARED IN ACCORDANCE WITH PART III OF THIS SECTION. 3. WITHIN 14 DAYS AFTER RECEIPT OF NOTICE TO PROCEED, SUBMIT THREE COPIES OF THE CONSTRUCTION SCHEDULE, PREPARED IN ACCORDANCE WITH PART III OF THIS SECTION. 4. ON THE FIRST WORK DAY OF EACH MONTH, FOLLOWING SUBMITTAL DESCRIBED, SUBMIT THREE COPIES OF THE CONSTRUCTION SCHEDULE AND THREE COPIES OF THE MATERIALS STATUS REPORTS UPDATED AS DESCRIBED IN PART III OF THIS SECTION. II MATERIALS - 1 . CONSTRUCTION ANALYSIS: 1 . GRAPHICALLY SHOW THE ORDER AND INTERDEPENDENCE OF ALL ACTIVITIES NECESSARY TO COMPLETE THE WORK, AND THE SEQUENCE IN WHICH EACH ACTIVITY IS TO BE ACCOMPLISHED, AS PLANNED BY THE CONTRACTOR AND HIS PROJECT FIELD SUPERINTENDENT IN COORDINATION WITH ALL SUB -CONTRACTORS WHOSE WORK IS SHOWN ON THE DIAGRAM. ACTIVITIES SHOWN ON THE DIAGRAM SHALL INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO: 1. PROJECT MOBILIZATION 2. SUBMITTALS AND ACCEPTANCES 3. PROCUREMENT OF EQUIPMENT AND CRITICAL MATERIALS 4. FABRICATION OF SPECIAL MATERIAL AND EQUIPMENT, AND THEIR INSTALLATION AND TESTING 5. FINAL CLEAN-UP 6. FINAL INSPECTION AND TESTING 2. MATERIALS STATUS REPORTS: 1. THE CONTRACTOR'S STANDARD MATERIALS STATUS REPORT FORM WILL BE ACCEPTABLE IF, IN THE ARCHITECT'S JUDGEMENT, IT PROVIDES SUFFICIENT PERTINENT DATA TO DETERMINE THAT MATERIALS PROCUREMENT FLOW IS ADEQUATE FOR ALL NEEDS OF THE WORK. 2. SHOW AT LEAST THE FOLLOWING INFORMATION: 1 ITEM DESCRIPTION, LISTED IN ACCORDANCE WITH SPECIFICATION SECTION NUMBER IN WHICH ITEM IS CALLED FOR 2. PURCHASE ORDER NUMBER AND DATE OF ISSUE 3. VENDOR NAME 4. DATE SHIPPED, AND SHIPPING MEANS UTILIZED 5. ESTIMATED DATE OF ARRIVAL AT JOB SITE 6. ACTUAL DATE OF ARRIVAL AT JOB SITE, AND RECEIVING REPORT NUMBER THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 III EXECUTION - 1 . PRELIMINARY ANALYSIS: 1. SHOW ALL ACTIVITIES OF THE CONTRACTOR UNDER THIS WORK FOR THE PERIOD BETWEEN RECEIPT OF NOTICE TO PROCEED AND SUBMITTAL OF CONSTRUCTION SCHEDULE REQUIRED. 2. SHOW CONTRACTOR'S GENERAL APPROACH TO THE REMAINDER OF THE WORK. 3. SHOW COST OF ALL ACTIVITIES SCHEDULED FOR PERFORMANCE BEFORE SUBMITTAL AND ACCEPTANCE OF THE CONSTRUCTION SCFIEDULE, 4. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE ABOVE CONSTRUCTION SCHEDULE. S. AS SOON AS PRACTICABLE AFTER RECEIPT OF NOTICE TO PROCEED, COMPLETE THE CONSTRUCTION ANALYSIS DESCRIBED ABOVE, IN PRELIMINARY FORM. MEET WITH THE ARCHITECT, REVIEW CONTENTS OF PROPOSED CONSTRUCTION SCHEDULE, AND MAKE ALL REVISIONS AGREED UPON. SUBMIT IN ACCORDANCE WITH ABOVE. 2. MATERIALS STATUS REPORT: 1 . AS SOON AS PRACTICABLE AFTER RECEIPT OF NOTICE TO PROCEED, COMPLETE THE CONSTRUCTION ANALYSIS DESCRIBED ABOVE, IN PRELIMINARY FORM. MEET WITH THE ARCHITECT, REVIEW CONTENTS OF PROPOSED MATERIALS STATUS REPORTS, AND MAKE ALL REVISIONS TO FORMAT AGREED UPON. 3. REVISIONS: 'I . MAKE ONLY THOSE REVISIONS TO ACCEPTED CONSTRUCTION SCHEDULE AND MATERIALS STATUS REPORTS AS ARE ACCEPTED IN ADVANCE BY THE ARCHITECT. END OF SECTION 01 310 Q14QQ Q ALITY,C'QNTROL: I WORK INCLUDED - 1. PERFORM ALL WORK IN ACCORDANCE WITH THE BUILDING CODE OF ALL LOCAL, STATE AND FEDERAL LAWS, CODES AND ORDINANCES HAVING JURISDICTION OVER THE WORK, INCLUDING ALL ADA ACCESSIBILITY GUIDELINES AND WITH ALL TRADE STANDARDS AND PRODUCT MANUFACTURE'S WRITTEN INSTRUCTIONS. 2. INDIVIDUAL REQUIREMENTS FOR QUALITY ASSURANCE ARE DESCRIBED IN PERTINENT SECTIONS OF THESE SPECIFICATIONS INCLUDING STRUCTURAL, MECHANICAL AND ELECTRICAL WORK: SEE 'S', 'FP', 'H' AND 'E' DRAWINGS. 3. IN CASE OF CONFLICT BETWEEN STANDARDS, THE MORE STRINGENT REQUIREMENT SHALL GOVERN. IN ALL CASES WHERE THERE IS A DISCREPANCY WITHIN OR BETWEEN DRAWINGS AND SPECIFICATIONS IN QUALITY OR QUANTIFY OF ANY ITEM, MATERIAL, INSTALLATION, DETAIL OR WORKMANSHIP THE CONTRACTOR SHALL USE THE LARGER QUANTITY, OR BETTER QUALITY TO PRODUCE THE HIGHEST QUALITY FINISHED WORK. 4. PROVIDE AND REMOVE, IN COORDINATION WITH THE PHASING OF THE WORK ALL TEMPORARY BARRIERS AND WALLS REQUIRED FOR THE PHASING AND PROTECTION OF THE CONTRACT WORK. MAINTAIN ALL TEMPORARY FACILITIES AND CONTROLS AS LONG AS NEEDED FOR THE SAFE AND PROPER COMPLETION OF THE WORK. II MATERIALS - 1. PRODUCTS USED IN THE WORK SHALL BE PRODUCED BY MANUFACTURERS ENGAGED IN THE MANUFACTURE OF SIMILAR ITEMS AND WITH A HISTORY OF SUCCESSFUL PRODUCTION ACCEPTABLE TO THE ARCHITECT. 2. COMPLY WITH REFERENCED STANDARDS AND BE IN STRICT ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COMPATIBILITY OF ALL MATERIALS REQUIRED FOR INSTALLATION, PROTECTION AND CLEANING OF THE MATERIALS SHALL BE VERIFIED WITH THE MANUFACTURERS OF THE MATERIALS TO BE INSTALLED, PROTECTED AND CLEANED. III EXECUTION - '1. ALL WORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE WITH, COORDINATED ACCEPTED SHOP DRAWINGS WHICH SHALL INCLUDE CORRECTIONS DUE TO FIELD CONDITION AND DIMENSION VERIFICATIONS. DETAILS OF SHAPES, MATERIALS AND FINISHES SHALL BE FOLLOWED INSOFAR AS THE ARCHITECTURAL DESIGN INTENT IS CONCERNED. DETAILS OF CONSTRUCTION, RELATION OF COMPONENT SECTIONS, METHODS OF CONSTRUCTION NOT SHOWN ON THE CONTRACT DOCUMENTS SHALL BE ESTABLISHED BY THE FABRICATOR AND THE INSTALLER WHO SHALL BE RESPONSIBLE FOR THE INTEGRITY, STRENGTH AND DURABILITY OF THE FABRICATION AND THE INSTALLATION OF THE WORK RESPECTIVELY. 2. THE INSTALLATION OF ALL WORK SHALL FOLLOW THE MANUFACTURER'S WRITTEN INSTRUCTIONS FOR SURFACE PREPARATION, TEMPERATURE AND MOISTURE CONTROL, METHODS OF INSTALLATION AND PROTECTION PROCEDURES. 3. THE BLENDING OF NEW SURFACES, MATERIALS AND FINISHES WITH SIMILAR SURFACES, MATERIALS AND FINISHES SHALL RESULT IN NO VISIBLE DEMARCATION BETWEEN EXISTING AND NEW WORK. HOLES, DAMAGE OR DEFORMATION RESULTING FROM REMOVALS UNDER THIS CONTRACT SHAL BE PATCHED TO THE SATISFACTION OF THE OWNER. REPLACE WITH NEW MATERIALS OR FINISHES, OR BOTH, TO MATCHED THOSE DAMAGED. END OF SECTION 01400 0i-11QTE TING Q1 5QQ - CONSTRUCTION FACIL1TI_ES AND TEMPORARY CONTROLS I WORK INCLUDED - I WORK INCLUDED - 'I. COOPERATE WITH THE OWNER'S SELECTED TESTING LABORATORY AND ALL 1. PROVIDE TEMPORARY ELECTRIC FEEDER FROM EXISTING BUILDING ELECTRICAL OTHERS RESPONSIBLE FOR TESTING AND INSPECTING THE WORK. SERVICE AT LOCATION AS DIRECTED. DO NOT DISRUPT OWNER'S NEED FOR CONTINUOUS SERVICE. COMPLEMENT EXISTING POWER SERVICE CAPACITY AND CHARACTERISTICS AS REQUIRED. PROVIDE POWER OUTLETS FOR 2. PROVIDE OTHER TESTING AND INSPECTING AS SPECIFIED TO BE FURNISHED BY CONSTRUCTION OPERATIONS, WITH BRANCH WIRING AND DISTRIBUTION THE CONTRACTOR IN THIS SECTION AND/OR IN OTHER SECTIONS OF THESE BOXES LOCATED AT EACH FLOOR, AS REQUIRED. PROVIDE FLEXIBLE POWER SPECIFICATION AND ON THE DRAWINGS, INCLUDING SITEWORK, STRUCTURAL, CORDS AS REQUIRED. PROVIDE MAIN SERVICE DISCONNECT AND MECHANICAL AND ELECTRICAL DRAWINGS. OVERCURRENT PROTECTION AT CONVENIENT LOCATION. 3. WHERE NO TESTING REQUIREMENTS ARE DESCRIBED, BUT THE OWNER DECIDES THAT TESTING IS REQUIRED, THE OWNER MAY DIRECT THAT SUCH TESTING BE 2. PERMANENT CONVENIENCE RECEPTACLES MAY NOT BE UTILIZED DURING PERFORMED UNDER CURRENT STANDARDS FOR TESTING. PAYMENT FOR SUCH CONSTRUCTION, UNLESS AGREED TO BY OWNER. TESTING WILL BE MADE AS DESCRIBED IN THIS SECTION. 3. PROVIDE AND MAINTAIN LIGHTING FOR CONSTRUCTION OPERATIONS TO ACHIEVE A MINIMUM LIGHTING LEVEL OF 4 WATT/SQ FT. MAINTAIN LIGHTING 4. THE OWNER WILL SELECT A PRE -QUALIFIED INDEPENDENT TESTING AND PROVIDE ROUTINE REPAIRS. LABORATORY. 5. THE OWNER WILL PAY FOR INITIAL SERVICES OF THE TESTING LABORATORY AS 4• PERMANENT BUILDING LIGHTING MAY NOT BE UTILIZED DURING FURTHER DESCRIBED IN THIS SECTION. CONSTRUCTION, UNLESS AGREED TO BY OWNER. 6. QUALITY ASSURANCE: 5. UTILIZE OWNER'S EXISTING HEAT PLANT, EXTEND AND SUPPLEMENT WITH TEMPORARY HEAT DEVICES AS NEEDED TO MAINTAIN SPECIFIED CONDITIONS 1 . THE TESTING LABORATORY WILL BE QUALIFIED TO THE OWNER'S FOR CONSTRUCTION OPERATIONS. ACCEPTANCE IN ACCORDANCE WITH ASTM E329. 6. PRIOR TO OPERATION OF PERMANENT EQUIPMENT FOR TEMPORARY HEATING 2. TESTING, WHEN REQUIRED, WILL, BE IN ACCORDANCE WITH ALL PERTINENT PURPOSES, VERIFY THAT INSTALLATION IS APPROVED FOR OPERATION, CODES AND REGULATIONS AND WITH SELECTED STANDARDS OF ASTM. EQUIPMENT IS LUBRICATED AND FILTERS ARE IN PLACE. PROVIDE AND PAY FOR OPERATION, MAINTENANCE, AND REGULAR REPLACEMENT OF FILTERS AND WORN OR CONSUMED PARTS. 7. PRODUCT HANDLING: 1 . PROMPTLY PROCESS AND DISTRIBUTE REQUIRED COPIES OF TEST REPORTS 7. MAINTAIN MINIMUM AMBIENT TEMPERATURE OF 50 DEGREES F IN AREAS AND RELATED INSTRUCTIONS TO ENSURE NECESSARY RE -TESTING AND WHERE CONSTRUCTION IS IN PROGRESS, UNLESS INDICATED OTHERWISE IN REPLACEMENT OF MATERIALS WITH THE LEAST POSSIBLE DELAY IN SPECIFICATIONS. PROGRESS OF THE WORK. 8. PROVIDE, MAINTAIN AND PAY FOR TELEPHONE SERVICE, FACSIMILE SERVICE AND A DEDICATED TELEPHONE LINE TO FIELD OFFICE AT TIME OF PROJECT MOBILIZATION. II MATERIALS - 9. EXISTING PUBLIC TOILET FACILITIES (MAINTAINED BY OTHERS) ARE 1 . PAYMENT FOR TESTING: AVAILABLE IN THE BUILDING. CONTRACTOR WILL ACCEPT RESPONSIBILITIES FOR AND VIGOROUSLY PROHIBIT THE COMMITTING OF NUISANCE ON THE SITE 1 . THE OWNER WILL PAY FOR INITIAL TESTING SERVICES REQUESTED BY THE OF THE WORK. OWNER. 10. PROVIDE TEMPORARY PARTITIONS AS INDICATED TO SEPARATE WORK AREAS 2. WHEN INITIAL TESTS INDICATE NON-COMPLIANCE WITH THE CONTRACT FROM OWNER AND TENANTS OCCUPIED AREAS, TO PREVENT PENETRATION OF DOCUMENTS, THE COSTS OF INITIAL TESTS ASSOCIATED WITH NOW DUST AND MOISTURE INTO OWNER AND TENANTS OCCUPIED AREAS, AND TO COMPLIANCE WILL BE DEDUCTED BY THE OWNER FROM THE CONTRACT PREVENT DAMAGE TO EXISTING MATERIALS AND EQUIPMENT. SUM. 3. WHEN INITIAL TESTS INDICATE NON-COMPLIANCE WITH THE CONTRACT 11. PROTECT INSTALLED WORK AND PROVIDE SPECIAL PROTECTION WHERE DOCUMENTS, ALL SUBSEQUENT RE -TESTING OCCASIONED BY THE SPECIFIED IN INDIVIDUAL SPECIFICATION SECTIONS. PROVIDE TEMPORARY AND NON-COMPLIANCE SHALL BE PERFORMED BY THE SAME TESTING AGENCY REMOVABLE PROTECTION FOR INSTALLED PRODUCTS. CONTROL ACTIVITY IN AND THE COSTS THEREOF WILL BE DEDUCTED BY THE OWNER FROM THE IMMEDIATE WORK AREA TO PREVENT DAMAGE. PROVIDE PROTECTIVE CONTRACT SUM. COVERINGS AT WALLS, PROJECTIONS, JAMBS, SILLS, AND SOFFITS OF 2. CODE COMPLIANCE TESTING: OPENINGS. PROTECT FINISHED FLOORS, STAIRS, AND OTHER SURFACES FROM TRAFFIC, DIRT, WEAR, DAMAGE, OR MOVEMENT OF HEAVY OBJECTS, BY 1. INSPECTIONS AND TESTS REQUIRED BY CODES OR ORDINANCES, OR BY PROTECTING WITH DURABLE SHEET MATERIALS. PLAN APPROVAL AUTHORITY, AND WHICH ARE MADE BY A LEGALLY CONSTITUTED AUTHORITY, SHALL BE PAID FOR BY THE CONTRACTOR, UNLESS OTHERWISE PROVIDED IN THE CONTRACT DOCUMENTS. '12. PROHIBIT "TRAFFIC OR STORAGE UPON WATERPROOFED OR ROOFED SURFACES. IF TRAFFIC OR ACTIVITY IS NECESSARY, OBTAIN RECOMMENDATIONS FOR 3. CONTRACTOR'S CONVENIENT TESTING: PROTECTION FROM WATERPROOFING OR ROOFING MATERIAL MANUFACTURER. 1. INSPECTING AND TESTING PERFORMED EXCLUSIVELY FOR THE CONTRACTOR'S CONVENIENCE SHALL BE THE SOLE RESPONSIBILITY OF THE 13. PROVIDE A FIELD OFFICE WITHIN THE CONSTRUCTION AREA FOR ALL CONTRACTOR. CONTRACTOR'S, SUPPLY AND STORAGE. PROVIDE SPACE FOR PROJECT MEETINGS, WITH ALL REQUIRED TABLE AND CHAIRS. THE FIELD OFFICE, 4. INSPECTION BY OWNER'S PERSONNEL: INCLUDING FURNITURE, WILL REMAIN THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE AFTER COMPLETION OF THE WORK. I . FROM TIME TO TIME, PERSONNEL IN THE EMPLOY OF THE OWNER MAY INSPECT THE WORK WHERE THE WORK IS IN PROGRESS, BUT SHALL HAVE NO AUTHORITY TO DIRECT THE CONTRACTOR OR REQUEST CHANGES IN 14. REMOVE TEMPORARY UTILITIES, EQUIPMENT, FACILITIES, MATERIALS, PRIOR TO THE WORK EXCEPT THROUGH THE ARCHITECT. SUBSTANTIAL COMPLETION INSPECTION. 15. CLEAN AND REPAIR DAMAGE CAUSED BY INSTALLATION OR USE OF III EXECUTION - TEMPORARY WORK. 1 . COOPERATION WITH TESTING LABORATORY: 16. RES -FORE EXISTING AND PERMANENT FACILITIES USED DURING CONSTRUCTION TO ORIGINAL CONDITION. RESTORE PERMANENT FACILITIES USED DURING 1 . REPRESENTATIVES OF THE TESTING LABORATORY SHALL HAVE ACCESS TO CONSTRUCTION TO SPECIFIED CONDITION. 'THE WORK AT ALL TIMES. PROVIDE FACILITIES FOR SUCH ACCESS IN ORDER THAT THE LABORATORY MAY PERFORM ITS FUNCTION. II MATERIALS - NOT USED 2. SPECIMENS AND SAMPLES FOR TESTING, UNLESS OTHERWISE PROVIDED IN III EXECUTION - NOT USED THE CONTRACT DOCUMENTS, WILL BE TAKEN BY THE TESTING PERSONNEL. SAMPLING EQUIPMENT AND PERSONNEL WILL BE PROVIDED BY THE TESTING LABORATORY. END OF SECTION 01 500 2. SCHEDULES FOR TESTING: 1. BY ADVANCE DISCUSSION WITH THE TESTING LABORATORY SELECTED BY THE OWNER, DETERMINE THE TIME REQUIRED FOR THE LABORATORY TO PERFORM ITS TEST AND TO ISSUE EACH OF ITS FINDINGS. 2. PROVIDE REQUIRED TIME WITHIN THE CONSTRUCTION SCHEDULE. 3. WHEN CHANGES OF CONSTRUCTION SCHEDULE ARE NECESSARY DURING CONSTRUCTION, COORDINATE SUCH CHANGES OF SCHEDULE WITH THE TESTING LABORATORY AS REQUIRED. 4. WHEN THE TESTING LABORATORY IS READY TO TEST ACCORDING TO THE ESTABLISHED SCHEDULE, BUT IS PREVENTED FROM TESTING OR TAKING SPECIMENS DUE TO INCOMPLETENESS OF THE WORK, ALL EXTRA CHARGES FOR TESTING ATTRIBUTABLE TO THE DELAY MAY BE BACK -CHARGED TO THE CONTRACTOR AND SHALL NOT BE BORNE BY THE OWNER. 3. ALTERNATIVE INSPECTION PROCEDURE: 1. THE ARCHITECT SHALL HAVE THE RIGHT TO REQUIRE ALTERNATIVE INSPECTION PROCEDURE OTHER THAN AS SPECIFIED WHEN, IN THE ARCHITECT'S JUDGEMENT, OTHER INSPECTIONS ARE REQUIRED TO DEMONSTRATE COMPLIANCE WITH THE CONTRACT DOCUMENTS. COSTS OF SUCH ALTERNATIVE INSPECTIONS WILL BE BORNE BY THE OWNER IF PRODUCTS ARE FOUND TO COMPLY; OTHERWISE, COSTS WILL BE BORNE BY THE CONTRACTOR. END OF SECTION 01410 Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12 -'1 -Uv CHECKED JOB NUMBER 0814 GENERAL SPECIFICATIONS Q10QQ PRODUCT HANDLING: Q1 12Q PROJECT R_E�'QRN DOCUMENTS: 01730 OPERA"TIONAD MAINTENANCE DATA: WORK INCLUDED - 5. CLOSEOUT SUBMITTALS: I WORK INCLUDED - I WORK INCLUDED - 1. THROUGHOUT THE CONSTRUCTION PERIOD USE ALL MEANS NECESSARY FOR 1. CLOSEOUT SUBMITTALS INCLUDE, BUT NOT NECESSARILY LIMITED TO: 1. THROUGHOUT PROGRESS OF THE WORK OF THIS CONTRACT, MAINTAIN AN 1 . TO AID IN THE CONTINUED INSTRUCTION OF OPERATING AND MAINTENANCE THE SAFETY AND PROTECTION OF ALL PERSONS, PROPERTY AND MATERIALS ACCURATE RECORD OF ALL CHANGES IN THE CONTRACT DOCUMENTS, AS PERSONNEL, AND TO PROVIDE A POSITIVE SOURCE OF INFORMATION REGARDING BEFORE, DURING AND AFTER COMMENCEMENT OF THE WORK. 1. COMPUTER AIDED DRAFTED (CAU) "AS -BUILT" RECORD SETS AND DESCRIBED BELOW. THE PRODUCTS INCORPORATED IN THE WORK, FURNISH AND DELIVER THE ASSOCIATED DISKS. DATA DESCRIBED IN THIS SECTION AND IN PERTINENT SECTIONS OF THESE 2. OPERATION AND MAINTENANCE DATA. 2. UPON COMPLETION OF THE WORK OF THIS CONTRACT, "TRANSFER BY COMPUTER SPECIFICATIONS. 2. DOCUMENTS AFFECTING WORK OF THIS SECTION INCLUDE, BUT ARE NOT 3. WARRANTIES AND BONDS AIDED DRAFTING (CAD), THE RECORDED CHANGES TO A SET OF RECORD CAD NECESSARILY LIMITED TO THE SECTIONS IN DIVISION 1 OF THESE 4. KEYS AND KEYING SCHEDULE DOCUMENT, AS DESCRIBED IN III BELOW. 2. MAKE ALL SUBMITTALS IN STRICT ACCORDANCE WITH PROVISIONS OF SECTION SPECIFICATIONS AND ADDITIONAL PROCEDURES AS MAY BE PRESCRIBED IN 5. SPARE PARTS AND MATERIAL EXTRA STOCK 01300, OTHER SECTIONS OF THESE SPECIFICATIONS INCLUDING STRUCTURAL, MECHANICAL, AND ELECTRICAL WORK: SEE STRUCTURAL, MECHANICAL AND 6. EVIDENCE OF COMPLIANCE WITH GOVERNMENTAL AGENCIES HAVING JURISDICTION INCLUDING, BUT NOT NECESSARILY LIMITED TO - 3. THOROUGHLY COORDINATE ALL CHANGES WITHIN THE RECORD DOCUMENT, 3. REQUIRED CONTENTS OF SUBMITTALS MAY ALSO BE AMPLIFIED IN PERTINENT ELECTRICAL DRAWINGS AND SPECIFICATIONS. MAKING ADEQUATE AND PROPER ENTRIES ON EACH PAGE OF SPECIFICATIONS OTHER SECTIONS OF THESE SPECIFICATIONS. AND EACH SHEET OF DRAWINGS AND OTHER DOCUMENTS WHERE SUCH ENTRY 1. CERTIFICATES OF INSPECTION IS REQUIRED TO PROPERLY SHOW CHANGE. ACCURACY OF RECORDS SHALL BE 4. SUBMIT THREE CURIES OF THE FINAL MANUAL OR MANUALS "fhlE ARCHITECT 3. INCLUDE WITHIN THE CONTRACTOR'S QUALITY ASSURANCE REQUIREMENTS `L. CERTIFICATES OF OCCUPANCY SUCH THAT FUTURE SEARCH FOR ITEMS SHOWN IN THE CONTRACT DOCUMENT PRIOR "TQ INDOCTRINATION OF OPERATION AND MAINTENANCEE PERSONNEL. SUCH PROCEDURES AS ARE REQUIRED TO ASSURE FULL PROTECTION OF THE MAY REASONABLY RELY ON INFORMATION OBTAINED FROM THE ACCEPTED WORK. 7. CERTIFICATES OF INSURANCE FOR PRODUCTS AND COMPLETED RECORD DOCUMENTS. OPERATIONS 4. EXCEPT AS OTHERWISE ACCEPTED BY THE ARCHITECT, DETERMINE AND COMPLY 8. LIST OF SUBCONTRACTORS, SERVICE ORGANIZATIONS AND PRINCIPAL II MATERIALS - WITH MANUFACTURER'S RECOMMENDATIONS ON PRODUCT HANDLING, VENDORS, INCLUDING NAMES ADDRESSES AND TELEPHONE NUMBERS 4. MAKE ALL ENTRIES WITHIN 24 HOURS AFTER RECEIPT OF INFORMATION. 1 WHERE INSTRUCTION MANUALS ARE REQUIRED TO BE SUBMITTED UNDER OTHER STORAGE, AND PROTECTION. WHERETHEY CAN BE REACHED FOR EMERGENCY SERVICE AT ALL TIMES . SECTIONS OF -THESE SPECIFICATIONS, PREPARE IN ACCORDANCE WITH THE INCLUDING NIGHTS, WEEKENDS AND HOLIDAYS. 5. DELIVER THE WORK TO THE JOB SITE PROPERLY CONTAINED AND IDENTIFIED IN SUCH S. IN ADVANCE OF THE LOCAL AIRPORT AUTHORITIES FINAL INSPECTION THE FOLLOWING: QUANTITIES AND AT SUCH TIME AS TO ASSURE THE CONTINUITY OF THE CONTRACTOR SHALL SUBMIT THE FINAL RECORD CAU DOCUMENTS TO THE INSTALLATION. II MATERIALS - NOT USED ARCHITECT TO SECURE THE ARCHITECT'S ACCEPTANCE. 1. FORMAT: 6. MAINTAIN PACKAGED MATERIALS WITH SEALS UNBROKEN AND LABELS INTACT III EXECUTION - NOT USED SIZE 8 1/2" X 1 1 ". PAPER WHITE BOND, AT LEAST 20 LB. WEIGHT. UNTIL TIME OF USE. END OF SECTION 01700 TEXT NEATLY TYPEWRITTEN. 7. PROMPTLY REMOVE DAMAGED MATERIALS AND UNSUITABLE ITEMS FROM THE DRAWINGS 1 1 " IN HEIGHT PREFERABLE; BIND IN WITH TEXT; FOLDOUTS JOB. SITE, AND PROMPTLY REPLACE WITH MATERIALS MEETING THE SPECIFIED 01 710 CLEANING: ACCEPTABLE; LARGER DRAWINGS ACCEPTABLE, BUT FOLD TO REQUIREMENTS, AT NO ADDITIONAL COST TO THE OWNER. II MATERIALS - FIT WITHIN THE MANUAL AND PROVIDE A DRAWING POCKET WORK INCLUDED - INSIDE REAR COVER OR BIND IN WIIhI TEXT. 1 . PROMPTLY FOLLOWING AWARD OF CONTRACT, SECURE FROM THE ARCHITECT, 1 . THROUGHOUT -THE CONSTRUCTION PERIOD MAINTAIN THE JOB SITE IN A AT NO CHARGE TO THE CONTRACTOR ONE COMPLETE SET OF ALL DOCUMENTS 2. PROVIDE FRONT AND BACK CURERS FOR EACH MANUAL, USING DURABLE II MATERIALS - NOT USED STANDARD OF CLEANLINESS AS DESCRIBED IN THIS SECTION. COMPOSING THE CONTRACT. MATERIAL ACCEPTED BY THE ARCHITECT AND CLEARLY IDENTIFIED ON OR 2. IN ADDITION TO STANDARDS DESCRIBED IN THIS SECTION, COMPLY WITH ALL THROUGH THE FRONT COVER WITH AT LEAST THE FOLLOWING INFORMATION: III EXECUTION - REQUIREMENTS FOR CLEANING UP AS DESCRIBED IN VARIOUS SECTIONS OF 2. AT A TIME NEAR THE COMPLETION OF THE WORK, PRIOR TO THE REQUEST FOR THESE SPECIFICATIONS AND WITH ALL PERTINENT REQUIREMENTS OF THE FINAL INSPECTION, SECURE FROM THE ARCHITECT AT NO CHARGE TO THE 1. OPERATING AND MAINTENANCE INSTRUCTIONS 1. PROTECT FINISHED SURFACES, INCLUDING JAMBS AND SOFFITS OF OPENINGS LANDLORD AND ALL OTHER GOVERNMENT AGENCIES HAVING JURISDICTION. CONTRACTOR, CAD FILES ON DISK OF ALL DOCUMENTS INCLUDED IN THE 2. NAME OFCONTRACTOR USED AS PASSAGEWAYS, THROUGHOUT WHICH EQUIPMENT AND MATERIALS CONTRACT. SUBJECT OF 3. GENERAL SUBJECT OF THIS MANUAL ARE HANDLED. 3. CONDUCT DAILY INSPECTION, AND MORE OFTEN IF NECESSARY, TO VERIFY THAT III EXECUTION - 2. PROVIDE PROTECTION FOR FINISHED FLOOR SURFACES IN TRAFFIC AREAS PRIOR REQUIREMENTS OF CLEANLINESS ARE BEING MET. 3. CONTENTS: TO ALLOWING EQUIPMENT OR MATERIALS TO BE MOVED OVER SUCH SURFACES. 1. IMMEDIATELY UPON RECEIPT OF THE JOB SET DESCRIBED ABOVE, IDENTIFY 1. INCLUDE AT LEAST THE FOLLOWING: 4. SUBMIT MANUFACTURERS WRITTEN INSTRUCTIONS OF THE PROPER CLEANING EACH OF THE DOCUMENTS WITH THE TITLE RECORD DOCUMENTS - JOB SET". MATERIALS AND APPLICATIONS REQUIRED FOR THEIR PRODUCTS TO THE 1 IMMEDIATE INFORMATION TO THE LOCATION WITHIN THE MANUAL OF ALL 3. MAINTAIN FINISHED SURFACES CLEAN, UNMARRED, AND SUITABLY PROTECTED OWNER, PRIOR TO FINAL ACCEPTANCE. . EMERGENCY DATA REGARDINGTHE INSTALLATION. UNTIL ACCEPTED BY OWNER. 2. DO NOT USE THE JOB SET FOR ANY PURPOSE EXCEPT ENTRY OF NEW DATA II MATERIALS - AND FOR REVIEW BY THE ARCHITECT, UNTIL START OF TRANSFER OF THE DATA 4. IN THE EVENT OF DAMAGE, PROMPTLY MAKE REPLACEMENTS AND REPAIRS TO TO FINAL RECORD CAD DOCUMENTS. 2. COMPLETE INSTRUCTIONS REGARDING OPERATION AND MAINTENANCE THE ACCEPTANCE OF THE ARCHITECT AND AT NO ADDITIONAL COST TO THE 1. PROVIDE ALL REQUIRED PERSONNEL, EQUIPMENT, AND MATERIALS TO MAINTAIN OF ALL EQUIPMENT INVOLVED, INCLUDING LUBRICATION, OWNER. THE SPECIFIED STANDARD OF CLEANLINESS. 3. MAINTAIN THE JOB SET AT THE SITE. DISASSEMBLY, AND RE -ASSEMBLY. 5. ADDITIONAL TIME REQUIRED TO SECURE REPLACEMENTS AND TO MAKE REPAIRS 2. USE ONLY THE CLEANING MATERIALS AND EQUIPMENT WHICH ARE COMPATIBLE 4. IN MOST CASES ON THE DRAWINGS, ARRANGEMENT OF CONDUIT AND AND 3. COMPLETE NOMENCLATURE AND PART NUMBER OF ALL REPLACEABLE WILL NOT BE CONSIDERED BY THE ARCHITECT TO JUSTIFY AN EXTENSION IN WITH THE SURFACE BEING CLEANED, AS RECOMMENDED BY THE CIRCUITS, PIPING, DUCTS, AND OTHER SIMILAR ITEMS, IS SHOWN PARTS, NAME AND ADDRESS OF NEAREST VENDOR, AND ALL OTHER THE CONTRACT TIME OF COMPLETION. MANUFACTURER OF THE SURFACE BEING CLEANED. SCHEMATICALLY AND IS NOT INTENDED TO POTRAY PRECISE PHYSICAL LAYOUT. PERTINENT DATA REGARDING PROCUREMENT PROCEDURE. FINAL PHYSICAL ARRANGEMENT IS AS DETERMINED BY THE CONTRACTOR END OF SECTION 01 600 SUBJECT TO THE ARCHITECT'S ACCEPTANCE. HOWEVER, DESIGN OF FUTURE III EXECUTION - MODIFICATIONS OF THE FACILITY MAY REQUIRE ACCURATE INFORMATION AS TO 2. COPY OF ALL GUARANTEES AND WARRANTIES. 01700CONTRACT CLOSEOUT: PHYSICAL ARRANGEMENT OF ITEMS WHICH ARE SHOWN ONLY THE FINAL PHY�T 1. RETAIN ALL STORED ITEMS IN AN ORDERLY ARRANGEMENT ALLOWING MAXIMUM SCHEMATICALLY ON THE DRAWINGS. 3. MANUFACTURER'S BULLETINS, CUTS, AND DESCRIPTIVE DATA, WHERE WORK INCLUDED - ACCESS, NOT IMPEDING DRAINAGE OR TRAFFIC, AND PROVIDING THE REQUIRED r PERTINENT, CLEARLY INDICATING THE PRECISE ITEMS INCLUDED IN THIS PROTECTION OF MATERIALS. 5. THE PURPOSE OF FINAL RECORD CAD DOCUMENTS IS TO PROVIDE FACTUAL INSTALLATION AND DELETING, OR OTHERWISE CLEARLY INDICATING, ALL 1. PROVIDE AN ORDERLY AND EFFICIENT TRANSFER OF THE COMPLETED WORK TO 2. DO NOT ALLOW THE ACCUMULATION OF SCRAP, DEBRIS, WASTE MATERIAL, INFORMATION REGARDING ALL ASPECTS OF THE WORK, BOTH CONCEALED AND MANUFACTURER' DATA WITH WHICH THIS INSTALLATION IS NOT THE OWNER IN ACCORDANCE WITH THE CONTRACT DOCUMENT REQUIREMENTS AND OTHER ITEMS NOT REQUIRED FOR CONSTRUCTION OF THIS WORK. VISIBLE, TO ENABLE FUTURE MODIFICATIONS OF DESIGN TO PROCEED WITHOUT CONCERNED. SUCH OTHER DATA AS REQUIRED IN PERTINENT OTHER INCLUDING BUT NOT NECESSARILY LIMITED TO THE GENERAL CONDITIONS, AND EXPENSIVE SITE MEASUREMENT, INVESTIGATION, AND SECTIONS OF THESE SPECIFICATIONS. SUPPLEMENTARY CONDITIONS AND DIVISION 1 OF THESE SPECIFICATIONS.LENGTHY EXAMINATION. 3. AT LEAST ONCE A WEEK, AND MORE OFTEN IF NECESSARY, COMPLETELY REMOVE ALL SCRAP, DEBRIS, AND WASTE MATERIAL FROM THE JOB SITE. 6. FOLLOWING RECEIPT OF THE CAD FILES ON DISK DESCRIBED ABOVE, AND PRIOR 2. QUALITY ASSURANCE: TO START OF TRANSFER OF RECORDED DATA THERETO, SECURE A REVIEW BY III EXECUTION - NOT USED THE ARCHITECT OF ALL RECORDED DATA. MAKE ALL REQUIRED REVISIONS. 1 . PRIOR TO REQUESTING INSPECTION, USE ADEQUATE MEANS TO ASSURE THAT 4. PROVIDE ADEQUATE STORAGE FOR ALL ITEMS AWAITING REMOVAL FROM THE THE WORK IS COMPLETED IN ACCORDANCE WITH THE SPECIFIED REQUIREMENTS JOB SITE, OBSERVING ALL REQUIREMENTS FOR FIRE PROTECTION AND c END OF SECTION 01730 AND IS READY FOR REQUESTED INSPECTION. PROTECTION OF THE SITE AND THE OWNER'S PROPERTY. 7. CAREFULLY TRANSFER ALL CHANGE DATA SHOWN ON THE JOB SET OF RECORD DRAWINGS TO THE CORRESPONDING CAD FILES ON DISK, COORDINATING THE CHANGES AS REQUIRED, AND CLEARLY INDICATING AT EACH AFFECTED DETAIL 2. PRIOR TO FINAL INSPECTION AND OCCUPANCY VERIFY THAT ALL S. DAILY, AND MORE OFTEN IF NECESSARY, INSPECT THE SITE AND PICK UP ALL AND OTHER DRAWING THE FULL DESCRIPTION OF ALL CHANGES MADE DURING Q1740_WAR_ AR-NTIES_ANI� zl A�NTEES: PENETRATIONS, INCLUDING EXISTING, THROUGH FIRE RATED ' SCRAP, DEBRIS, AND WASTE MATERIAL. REMOVE ALL SUCH ITEMS TO A PLACE CONSTRUCTION AND THE ACTUAL LOCATION OF ITEMS DESCRIBED ABOVE. FLOORS/WALLS ARE PROPERLY SEALED. DESIGNATED FOR THEIR STORAGE. MAINTAIN THE SITE IN A NEAT AND ORDERLY CALL ATTENTION TO EACH ENTRY BY DRAWING A "CLOUD" AROUND THE AREA I WORK INCLUDED - CONDITION AT ALL TIMES. OR AREAS AFFECTED. MAKE ALL ENTRIES TO THE CAD FILES ON DISK NEATLY 3. SUBSTANTIAL COMPLETION: AND CONSISTENTLY IN BOLD LINES AND TEXT. IDENTIFY EACH CAD DISK AND 1 . THIS SECTION COVERS PREPARING AND SUBMITTING MANUFACTURER'S ALL OF THE DOCUMENTS WITHIN WITH THE TITLE "AS -BUILT RECORD SET". WARRANTIES AND GUARANTEES REQUIRED IN ACCORDANCE WITH THE 1. WHEN THE CONTRACTOR CONSIDERS THE WORK, OR DESIGNATED PORTION 6. -WEEKLY, AND MORE OFTEN IF NECESSARY, SWEEP ALL INTERIOR SPACES CONTRACT DOCUMENTS. THEREOF WHICH IS ACCEPTABLE TO THE OWNER IS SUBSTANTIALLY CLEAN. "CLEAN", FOR THE PURPOSE OF THIS SUB -PARAGRAPH, SHALL BE COMPLETE THE CONTRACTOR SHALL PREPARE FOR SUBMISSION TO THE INTERRUPTED AS MEANING FREE FROM DUST AND OTHER MATERIAL CAPABLE ARCHITECT A LIST OF ITEMS TO BE COMPLETED OR CORRECTED. OF BEING REMOVED BY USE OF REASONABLE EFFORT AND HANDFIELD BROOM. 8. SUBMIT THE COMPLETED TOTAL SET OF RECORD DOCUMENT CAD FILES ON II MATERIALS - DISK, AND THREE (3) BOUND (STAPLED) SETS OF ASSOCIATED PRINT-OUTS, IN NUMERICAL ORDER, TO THE ARCHITECT AS DESCRIBED ABOVE. 1. IN ACCORDANCE WITH SECTION 01300, SUBMITTALS AND SUBSTITUTIONS - 2. THE DATE OF SUBSTANTIAL COMPLETION OF THE THE WORK, OR 7. FOLLOWING THE INSTALLATION OF FINISH FLOUR MATERIALS, CLEAN THE DESIGNATED PORTION THEREOF, IS THE DATE CERTIFIED BY THE ARCHITECT FINISH FLOUR DAILY (AND MORE OFTEN IF NECESSARY) AT ALL TIMES WHILE WHEN CONSTRUCTION IS SUFFICIENTLY COMPLETE IN ACCORDANCE WITH WORK IS BEING PERFORMED IN THE SPACE IN WHICH FINISH MATERIALS HAVE 1. SUBMIT BLANK WARRANTY AND GUARANTEE FORMS FOR ACCEPTANCE NOT THE CONTRACT DOCUMENTS SO THE OWNER CAN OCCUPY OR UTILIZE THE BEEN INSTALLED. "CLEAN", FOR THE PURPOSE OF THIS SUB -PARAGRAPH, SHALL LATER THAN 30 DAYS AND BEFORE ANTICIPATED FINAL ACCEPTANCE THE WORK, OR DESIGNATED PORTION THEREOF FOR THE USE WHICH IT IS BE INTERPRETED AS MEANING FREE FROM ALL FOREIGN MATERIAL WHICH, IN AN K FORM, ONE COPY OF EACH FORM DATE. SUBMIT 4 COPIES OF EACH BLANK INTENDED. THE OPINION OF THE ARCHITECT MAY BE INJURIOUS TO THE FINISH FLOOR WILL BE RETURNED FOR CORRECTION OR FOR USE. MATERIAL. END OF SECTION 01 720 3. WITHIN A REASONABLE TIME AFTER RECEIPT OF THE LIST THE ARCHITECT 2. SUBMIT EXECUTED WARRANTY AND GUARANTEE FORMS FOR ACCEPTANCE WILL INSPECT TO DETERMINE THE STATUS OF COMPLETION. 8. EXCEPT AS OTHERWISE SPECIFICALLY PROVIDED, CLEAN" (FOR THE PURPOSE OF NOT LATER THAN 10 DAYS BEFORE THE ANTICIPATED FINAL ACCEPTANCE THIS ARTICLE) SHALL BE INTERPRETED AS MEANING THE LEVEL OF CLEANLINESS DATE. SUBMIT 4 COPIES OF EACH EXECUTED FORM, ONE COPY OF EACH GENERALLY PROVIDED BY STILLED CLEANERS USING COMMERCIAL QUALITY FORM WILL BE RETURNED FOR CORRECTION OR FOR USE. 4. FINAL COMPLETION: BUILDING MAINTENANCE EQUIPMENT AND MATERIALS. 1. UPON RECEIPT OF WRITTEN NOTICE FROM THE CONTRACTOR THAT THE 3. ACCOMPANY BLANK AND EXECUTED FORMS WIThI TRANSMITTAL FORM WORK IS READY FOR FINAL INSPECTION AND ACCEPTANCE AND UPON 9• PRIOR TO COMPLETION OF THE WORK, REMOVE FROM THE JOB SITE ALL TOOLS, CONTAINING THE FOLLOWING INFORMATION - RECEIPT OF A FINAL APPLICATION FOR PAYMENT, THE ARCHITECT WILL SURPLUS MATERIALS, EQUIPMENT, SCRAP, DEBRIS AND WASTE. CONDUCT PROMPTLY MAKE SUCH INSPECTION. FINAL PROGRESS CLEANING AS DESCRIBED IN ABOVE. 1 . ITEMS COVERED BY THE WARRANTY OR GUARANTEE 2. DATE SUBMITTED TO ARCHITECT 2. THE CONTRACTOR SHALL CERTIFY THAT: 10. VISUALLY INSPECT ALL SURFACES AND REMOVE ALL TRACES OF SOIL, WASTE 3. PROJECT TITLE AND NUMBER 4. SUPPLIER'S, MANUFACTURER'S OR SUBCONTRACTOR'S NAMES AND MATERIAL, SMUDGES AND OTHER FOREIGN MATTER. REMOVE ALL TRACES OF ADDRESSES 1 . CONTRACT DOCUMENTS HAVE BEEN REVIEWED. SPLASHED MATERIALS FROM ADJACENT SURFACES. REMOVE ALL PAINT 2. WORK HAS BEEN INSPECTED FOR COMPLIANCE WITH THE DROPPINGS, SPOTS, STAINS, AND DIRT FROM FINISHED SURFACES. USE ONLY CONTRACT DOCUMENTS. SPECIFIED MATERIALS AND EQUIPMENT. III EXECUTION -NOT USED 3. WORK HAS BEEN COMPLETED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 4. EQUIPMENT AND SYSTEMS HAVE BEEN TESTED AS REQUIRED, AND ARE 1 1 . CLEAN ALL GLASS, BOTH SIDES, INCLUDING EXISTING GLASS TO REMAIN. OPERATIONAL. REMOVE ALL LABELS. END OF SECTION 01 740 5. WORK IS COMPLETED AND READY FOR FINAL INSPECTION. 12. TO ALL SURFACES REQUIRING THE ROUTINE APPLICATION OF BUFFED POLISH, 3. THE ARCHITECT WILL MAKE AN INSPECTION TO VERIFY STATUS OF APPLY THE POLISH RECOMMENDED BY THE MANUFACTURER OF THE MATERIAL COMPLETION. BEING POLISHED. 4. WHEN THE ARCHITECT DETERMINES THAT THE WORK IS ACCEPTABLE 13. SCHEDULE FINAL CLEANING, TO BE DONE BY A PROFESSIONAL CLEANING UNDER THE CONTRACT DOCUMENTS, THE ARCHITECT WILL REQUEST THAT COMPANY, AS ACCEPTED BY THE ARCHITECT, TO ENABLE THE OWNER TO THE CONTRACTOR TO MAKE CLOSEOUT SUBMITTALS. ACCEPT A COMPLETELY PROFESSIONALLY CLEANED PROJECT END OF SECTION 01 710 THIS DRAWING AS AN .INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THEPROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA I DEMOLITION NOTES 1. G.C. SHALL DEMO AND REMOVE ALL EXISTING CON5TRUCTION REQUIRED FOR NEW WORK. CARE SHALL BE TAKEN 50 A5 TO PROTECT ANY ITEMS BEING REUSED. REMOVE ALL ITEMS NOT DEING REU5ED (CONDUIT, ETC.) --DO NOT JUST ADANDON. ALL ELECTRICAL CONDUIT TO DE REMOVED RACK TO FANEL 13OXE5. ALL DEMOLITION AND REMOVAL SHALL COMPLY WITH LANDLORD'S & TENANT'5 REQUIREMENTS. 2. G.C. 15 RE5FON51DLE TO VISIT SITE TO ASCERTAIN FULL EXTENT OF DEMOLITION. NOTIFY THE ARCHITECT IMMEDIATELY OF ANY INCON515TENCIES OR DISCREPANCIES WITH FLANS IN RELATION TO EXISTING FIELD CONDITIONS. 3. G.C. SHALL ERECTA CONSTRUCTION DARRICADE OR FROVIDE DUST DARRIER AS REQUIRED DY LANDLORD. 4. PROTECT EXISTING STRUCTURAL, STEEL & FIRE -PROOFING FROM DAMAGE. THE GC SHALL MAINTAIN ALL EXITING UL RATED FIRE5TOP5 AT EXISTING PENETRATION5 DURING DEMO AND CONSTRUCTION 5, G.C. TO COVER LANDLORD'5 OR TENANT'5 EXISTING HVAC RETURN AIR GRILLE5 FRIOR TO INTRODUCTION OF ANY CONSTRUCTION DUST INTO SPACE. 6. G.C. TO MAINTAIN FIRE-RATING5 OF PARTITIONS, COLUMNS, FLOOR AND CEILING ASSEMBLIES DURING DEMOLITION. %. SAVE AND FROTECT UTILITIES WHEN THEY SERVE THE DA5E DUILDING OR OTHER TENANTS. PRoTEC`T ALL EXISTING STRUCTURE TO REMAIN. DO NOT CUT, DAMAGE, OR COMFROMI5E THE EXISTING STRUCTURE IN ANYWAY. LANDLORD UTILITY INTERRUFTIONS MUST DE 5CHEDULED THROUGH THE LANDLORD'S REFRE5ENTATIVE AND WILL DE CONDUCTED DURING TIME5 CONVENIENT TO "THE LANDLORD AND SURROUNDING TENANT'S. 5. IF ANY AREAS OF LAN1)LOR1)'5 CONSTRUCTION OR TENAN"T'5 CONSTRUCTION TO REMAIN (CARPET, COLUMNS, CEILING, 5OFFIT5, ETC.) 15 DAMAGED, THE G.C. SHALL DE RESPONSIDLE FOR REPAIRING/REFLACING DAMAGED AREA TO MATCH EX15"TING. 9. G.C. TO VERIFY SALVAGE REQUIREMENT5 WITH LANDLORD AND TENAN"T FRIOR TO 5TARTING WORK. THE G.C. SHALL INQUIRE A5 TO THE STATUS OF ANY ITEM FOUND IN THE SPACE WHICH 15 NOT EXFRE55LY CALLED OUT ON THE CONSTRUCTION DOCUMENTS, 10, G.G. SHALL DE RESFON515LE FOR RE -LOCATING AND STORING ALL ITEMS CALLED FOR "TO DE RE -USED. THE G.C. SHALL, AT HI5 COST, KEFLACE ANY ITEMS LOST, DAMAGED, OR STOLEN WHILE IN HI5 CARE, WHERE EX15TING TEMP WATERFALL EX15T A5 A 13ARRICADE, FRAME FROM TOF OF UNIT TO C.EILNG A5 KEOUIRED 5/6" GYP'. DD. FAINTED I— WHITE' OR A5 OT HERW54 REOUIKED 13Y LANDLOKDI I 5/8" METAL 5T UD5 @ 16" O,C. SOUND DATT I1\15ULATION I I I 4" HIGH'bLACK' VINYL b4DE OR A5 OT'HEKWI5E REOUIRED DY LANDLORD I PROVIDE V150UEEN DU51'BARKIEK BRACING - Do NOT ATTACH bKACE5,fo LANDLORD'S FINISHED MATEK'1AL5 (TILE, CEILING, WALLS) CONT. 1'LYvvO0D UNDER METAL. SPUD FRAMING COUNTER WEIGHT A5 REQUIRED TO SECURE BARRICADE D ETAI L TEMPORARY CONSTRUCTION 13ARRICADE v ^ 1!„O!! VERIFY EXI511N0 EXP, JT. EXTERIOR OF BUILDING ROOF BELOW I UL RATED FIRESTOP A 2- Vit; i.4 . .. ......... . E�jST/ NG TE Mp �V ,� TERM CONCOURSE DAKKICADE EXTENDS ' IVI/111`!It'\I' LAIJIINl7OrIVI`lNIXI`�V :3 UNITIL NEW REDE5IGNED SPRINKLER I TEMPOKARY CONSTRUCTION GRID 15 APPROVED AND INSTALLED I ' BARRICADE 5EE DETAIL TH15 i SHEET �>If3Zss-i3f'k�'it::.5i,4`t iF.'}..,'e '..,. .)^ �.... �i... ._.:.fa�f -.}. 'it > 2..5 .!,43.Sa... ,s. ..3... .. .t ......,r-..... !i�.... a3e ..:1:•..� i.4z; z..L ta;fi.$i .it..3.;ts:+, ..,.._. i�.3t.. .o!. :?}!<...1;L 4:3i!aY ., ii: :. F kcsrlEil .§ m ,`i}.L" rtl£Y.ds k'°''r E. Oi? l : SA. ..1 . asl,i•A Kilt I .$tv g.kj: ., ., < R. : f ..,,k a . 4 . ♦fi.., ..� .�>+ .......... :.3.. ,C:.'� , ts...,,..ti: ;�43 }a+...3, ,..._\,. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION I 2-22-09 TENANT REVISIONS EX151ING 6_0" HIGH DARKICADE - EXTEND To CLO Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA EXI TING COLUMN 10 REMAIN CONCOURSE DRAWN DATE 12-1-v� CHECKED JOB NUMBER 08'14 DEMOLITION FLOOR PLAN BARRICADE PLAN M ETALU NA Architecture & Design P.C. 1665 1 lighway 588 Ellisville, MS 39,137 TEL 601.9 14.6909 FAX 601.763.,1886 www, M ETALU N, el`nail: me alunZC REMOVE EXI5TING NON-FUNCTIONING CONPEN5ING UNIT ANP REPAIR EXI 5'rING COKKEGATED METAL 51PING A5 KEGIUIKEP DY A1KFOK'r- PATCH All HOLF5 IN WALL AND FIKE CAIJLF A5 KE0T)- IF KEO'D UY AIRPORT- THE WORK 10 PATCH METAL 51DING MAY 13E DONE DY THE AIRPOKT5 MAINTANCE OR 5UE AT T ENANT 5 EXF EN5E- GC SHALL CAKKY ALL C05- r IN 1310 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 DEMOLITION CEILING PLAN 1/4" = 11,0" NO. DATE REVISION I 2-22-09 TENANT REVISIONS AIRPORT CONCOURSE EXI5TING 5U5PENDED CEILING TO DE REMOVED A5 KECIIJIKEP FOK I`IEVV 4VA L. L LANPLOKD'5 EXI5TING 5U5PEr1MED CEILING TO REMAIN Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL_ DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA LANDLORD'5 EXI5TING 51J5PENDEP CEILING TO KEMAII`I m DRAWN DAI L 12=1-oa CHECKED JOB NUMBER 0814 - DEMOLITION CEILING PLAN D-1.1 E V I to"i'l 0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA LIFE SAFETY PLAN 1 :0111 U Lvi. 1 -4 �m �l LO -1 C, 1, FOR ALL EQUIPMENT TO DE SELECTED DY TENANT ANP IN5TALLEP DY G.C.. AN EQUIPMENT ALLOWANCE WILL 5E ADDED TO ALL 13109. THE TENANT WILL SELECT AND OKPER EQUIPMENT ANP SEND THE PURCHASE ORPER TO THE GC. FOR IMMEPIATE THE G.C, 5HALL RECEIVE, UNLOAD, AND UNCRATE FRODIJCTS, INS1 LG r FUR CUIvIFLE l"ENE55 Ori DAMAGE, FIAt IDLE AND POKE PRODUCTS. AN'( I-rElvlS DAMAGED AF'rEK KECEIr,,I` 5HALL BE REFAIKED OK KEFLACEP BY T HE G.C. THE G.C. 5HALL INF)TAL1_ AND FIN15H ITEMS FEF: MANUFAcrUKER'S IN5TRUCrION5• 2. T TIE G.C. 5HAL.L RECEIVE, UNLOAD, UNCRATE FROPUCT 5, HANDLE, AND 5 TORE ITEM5 THAT ARE FURNI5HE1) BY TENANT AND IN51AL.LEU BY TENANT. Coor,bmArE WITH TENANT REFRESENTATIVE. 3. THE G.C. 5HALL VERIFY ALL F 04VER, WATER, AND DRAINAGE F.ECIIJIREMENTS WITHTHE MANUFACI U}:E1. S 5PECIFICATION5/IN51 RIJCTION5 FOR THE EQUIPMENT "r0 BE IN5IALLED FKIOF: T"0 S'rAR'r OF cDNF)'rRUCr10N. THE G.C, 5HALL COOKDINArE THE EXACT LOCATION AND 51ZE OF EACH FIECE OF EQUIPMENT ANO THE REQUIREP I1\15TALL_ATION CONNECTION5 WITH THE TENANT KEPRE5ENTATIVE PRIOR TO IN51-AL.LATION. EQUIPMENT SCHEDULE CONSTRUCTION NOTES 1, ALL PIMEN51ON5 ARE 10 FACE OF FINISHED MATERIAL (GYFK BD„ 10. SAVE ANP FKOTECT u'rll_ITIE5 WHEN THEY SERVE THE BA5E ELECTRICAL TILE, ETC,'.) UNLE55 OTHERWI5E NOT EP. BUILDING OR OTFIER TENANT5. FKOTECT ALL EXISTING 5TKUCTUKE 0 CA5H REGISTER AND FIKE-FROOFING TO REMAIN, DO NOr CUT, DAMAGE, OR 2. f AR'rrr10N5 5HOWN 5HADED INDICATE NEW FAKTITION5 OR COMNr:OM15E THE EXI5TING 5TKUCTUKE IN ANYWAY. LANDLOKD G.C. CON51-RUCTION, UN5HAPEP 1'ARTITION5 INDICATE EXI5TING U'rILI FY INTERRUFTION5 MU51'SE 5CHE1)ULEU THKOUGf-I'rHE 'SOUTHERN 5TORE FIXTURE INC' MPC-V8HH5C PA F:f"rrIUNS/COLUMNS TO KEMAIN. BRACE FARTITIOH 5 "r0 EXISTING LANDLORD'5 KEFKE5ENTATIVE AND WILL BE CONDUCTED PUKING TENANT 5 r KUCTURE ADOVE. TIME5 CONVENIENT TO THE LANPLOKP ANP 5UKKOUHUING FLAT 5CREEN D15PLAY VERIFY TEHANT'5. 3. ALL METAL 5'rUD510 BE 5 518", 20 GA, 916" O.C., UNLE55 G.C. 0 OTHEKWI5E NOTED. ALL GYP 131). TO 13E 50" TYFE'X', UNLE55 IF ANY AREAS OF LANDLOKV5 CON51-RUCTION (GARFET, VERIFY OTHERWI5E NOTED. TL COLUMN5, CEILING, TILE, ETC.) 15 DAMAGED, THE G.C. SHALL BE G.C. LANDLORD, ALL POOR COMFONENT5 TO CONFORM TO LAHOLORV5 5TANDAR05, PAINT LANPLORO'S 51PE OF POOR & KE51`01\151BL.E FOK REPAIRING/REPLACING DAMAGED AREA TO 4, ALL WOOF FURRING/BLOCKING TO BE FIFE-KETAKOENT TREATED MATCH EXI5TING. WOOF. G.C. TO (.;OVER/REMOVE LANPLORV5 OR. TENANV5 EXI5TING HVAC 5. G.C.TO COOKDINAI E ANY ALARMING REQUIREMENT 5 WITH THE RETURN AIR 0KII_LE5 FKIOK TO INTKOPLic'nON OF ANY TENANT REFRE5ENTATIVE AND LANPLOKI). 12. CON5TKuc-rioN UL15'r Irmo 5f ACE. 6. ANY PENETRATIONS ,rHKU FIKE-RAT Ep WALLS, FLOOK5, AND LANDLORD KEQUIKEMENT5 FOK "rHE BAKRICADE CON5TKL1CrioN, CEILING5 SHALL DE 5LEEVED ANP 5EALED WITH AFFROVEP INCLUDING ACCE55 DOOR AND KEYING, SHALL SUFEK5EDE NOTES FIKE-KATED 5EALANT. G.C, TO COOKOINATE PENETRATION5 WITH AND PETAiI.5 5HOWN IN THE COH51-RUCTION DOCUMENT 5. LAN DLOKD. 13. THE DARICAUE LOCATION SHALL NOT IMFEDE LIFE SAFE"rY OF V. ANY 5LAD FENETKATION5 TO BE MADE MU5T PIE X-KAYEU AND THE AREAS BEING U5EU BY "rHE FUDLIC. THE BARRICADE 5HALL NOT LOCATION APFKOVEU BY THE LANDLORD FKIoR To COKING OF SLAB. INTERFERE WITH THE V15 m-rY OF EXI-r 51GN5. THE G.C. 5HALL ALL CURE DRILLING 5HALL- FOLLO'vV LANUI.OKU'5 REQUIKEIvIEHT 5. PROVIDE TEMFOKAKY EXITING 510NAGE TO DIKECr FUBLIC 14, AROUND BAKKICADE IF NEEDED. COORDINATE WORK WITH G.C. TO MAINTAIN FIKE-RAT ING5 OF PART IT ION5, COLUMNS, FLOOR LANULOKU AND LOCAL FIRE MAR5HAL/BUILDING DEFAKI MEN_r 6. AND CEILING A55EMBLIE5 DURING CONST RUC:r10N. OFFICIAL. G.C. 5HALL ERECT A CON51-RUCTION BARRICADE A5 REQUIRED BY THE LANDLORD. THE BARRICADE 5HALL BE TYPE AND LOCATION A5 9. SHOWN ON CON5TKUCT10N FLAN UNLE55 OTHEKWI5E KEQUIRED BY 'rHE LANDLORD, 1 :0111 U Lvi. 1 -4 �m �l LO -1 C, 1, FOR ALL EQUIPMENT TO DE SELECTED DY TENANT ANP IN5TALLEP DY G.C.. AN EQUIPMENT ALLOWANCE WILL 5E ADDED TO ALL 13109. THE TENANT WILL SELECT AND OKPER EQUIPMENT ANP SEND THE PURCHASE ORPER TO THE GC. FOR IMMEPIATE THE G.C, 5HALL RECEIVE, UNLOAD, AND UNCRATE FRODIJCTS, INS1 LG r FUR CUIvIFLE l"ENE55 Ori DAMAGE, FIAt IDLE AND POKE PRODUCTS. AN'( I-rElvlS DAMAGED AF'rEK KECEIr,,I` 5HALL BE REFAIKED OK KEFLACEP BY T HE G.C. THE G.C. 5HALL INF)TAL1_ AND FIN15H ITEMS FEF: MANUFAcrUKER'S IN5TRUCrION5• 2. T TIE G.C. 5HAL.L RECEIVE, UNLOAD, UNCRATE FROPUCT 5, HANDLE, AND 5 TORE ITEM5 THAT ARE FURNI5HE1) BY TENANT AND IN51AL.LEU BY TENANT. Coor,bmArE WITH TENANT REFRESENTATIVE. 3. THE G.C. 5HALL VERIFY ALL F 04VER, WATER, AND DRAINAGE F.ECIIJIREMENTS WITHTHE MANUFACI U}:E1. S 5PECIFICATION5/IN51 RIJCTION5 FOR THE EQUIPMENT "r0 BE IN5IALLED FKIOF: T"0 S'rAR'r OF cDNF)'rRUCr10N. THE G.C, 5HALL COOKDINArE THE EXACT LOCATION AND 51ZE OF EACH FIECE OF EQUIPMENT ANO THE REQUIREP I1\15TALL_ATION CONNECTION5 WITH THE TENANT KEPRE5ENTATIVE PRIOR TO IN51-AL.LATION. EQUIPMENT SCHEDULE NO. ITEM MODEL/MANUFACTURER SIZE ELECTRICAL FURNISHED BY INSTALLED BY 0 CA5H REGISTER VERIFY VERIFY VERIFY TENANT G.C. OOPEN 2 FACE KEFKIGEKATE'P CA5E 'SOUTHERN 5TORE FIXTURE INC' MPC-V8HH5C SO'I/2"W x 29 5/8"P x 7t3 /gIIFI 120/240 4 WIRE WITH NEUTKAL N E1vIA: L14-201; '16.OA TENANT G.C. O42" FLAT 5CREEN D15PLAY VERIFY VERIFY VERIFY TENANT G.C. 0 PIGITAL FROCE55oK, VERIFY VERIFY VERIFY TENANT G.C. 0163hAR1TITION LEND MARK EXISTING PARTITION TO REMAIN. G.0TO PREPARE EX15 TING WALL 5URFACE5 FOR NEW FINIE)HE5 WHEKE REQUIRED. I HAF DWAKE/REMAM5 NEW PARTITION - WALL TYPE 1. 5/8" GYP BD, ON PUBLIC 510E OF 55/6" METAL 61-1-J25-004 '. NLE55 0"TF� FKVt P IT d�N DWGS. U5E (2) #& x 7/16" PAN HEA 2 L`CONNECTION. 5EGIJKE TO 5LAB WITH MIN. Vl8" LONG POWER -1)1_'17 2 IAX.- 0.118" DIA HILTI X -PW. FINI5HEP FACE OF NEW PARTITION NOT USED -2 TO BE FL.U51 I OWN. ExrENP OiYK Bp. 3" ABOVE LAY -IN CEILING lF 64PE-01` FACE AND TO DECK ON AIRFORT SIDE TO MATCH EXISTING �YKF�t �HES A5 DETAILED, - � �.!) NE PAKTTT�ION WALL TYPE 4�/8" GYF U. 01` 3 5/8" METAL Sl OF S <c� 'I " OC., -U511(2) #8 x7/16'' PAN HEAD E re Al -Ak{'C:i`}PIF} 14C-)fK1. '✓ tiJ1tC fTkL TL1 (' c' FLI �i(G "C) I - 0.116" PIA HILT I X -PW. FINI51-1E1) FACE OF NEW FART"ITION TO BE FLU511 WITH APJACENT EXI5TING PARTITION5 WHERE 51-IOWN. PF:OVIDE FINISH MATERIALS A5 DETAILED. SEE DETAIL 1/A4.0 �2 NEW MILLWORK FIXTURES. 5EE MILLWORK PLAN 51-IEE"i' F-1.0 Irl- E IN FLOOR A5 KEQ'D. FROVIDE OUT5I0E CYLINDER. LOCK ANP IN51PE QUICK RELEA5E 900 (MAX,) "THUMB TUKN FOR TEMPORARY CONSTRUCTION DARRICAPE, 5EE DETAIL ON 5HEEr P-1.0 J EMEF'GENCY EXIT, IN5TALLKHON 5HALL DE B`( GRILLE MAN UFACTUKER'5 AU'riIOKIZED DISTRIBUTOR OR AlDOOR SCHEDULE MARK v 51 ZVE V I HAF DWAKE/REMAM5 ��; A5 c A� �H04V�1 510E -GLUING GRILLE A5 MANF. BY "F)YNAFLAIR" 800 840-3962 OK EQUAL- "ELEGANCE-Ff"' ANO[). ALUM• WITH ( ) �.!) PERG:ArED FANEL5 FROVIOE OPTIONAL ONE-5TEF TOP & BOTTOM LOCKING 5Y5TEM ON EACH END WITH DUB rPKOOF (VERIFY EXIE)ITNG GATE Irl- E IN FLOOR A5 KEQ'D. FROVIDE OUT5I0E CYLINDER. LOCK ANP IN51PE QUICK RELEA5E 900 (MAX,) "THUMB TUKN FOR V A TRACK FOR KEU5E) EMEF'GENCY EXIT, IN5TALLKHON 5HALL DE B`( GRILLE MAN UFACTUKER'5 AU'riIOKIZED DISTRIBUTOR OR REF .E5ENTATIVE. G.C. 5HALL INSTALL REC:IIJIRED BLOCKING. GC 5HALL COORDINATE EXACT LOCATION AND 51ZE5 OF . 7.7.71 f.. AL REQUIRED CUTOUTS, 5FACE REQUIREMENTS, AND DIMEN5101\15 FOR 5UFFOKT WITH 0.1 -HER FIN15H WORK. -��-� `-�'- C0 f"AIK3x6*o'er J �J c- c 5.C. WOOD ROOK OF. HOLLOW METAL & ME"I"AL FRAME, r I�UVIDE CLG �f=K MOU�I TED UN rE�IAN rS �10E OF DUUf.• -1-U (5EE SHEET P- 1.0) LOCK5Ef''ro BE'EN,rKANCE/OFFICE' Fal WITH HANPICAFFEU-ACC:E551BLE LEVER, TYFE & FIN15H MATCH LAMDLORP -`• (G c J , ,� � c 51-ANDARD, NO HA51`5 OR 1-A[)LOCK✓ f-EKMITTEP. COORPINA'1'E KEYING OF LOCKS WITH TENANT KEI`RE5ENT'ATIVE ANP LANDLORD, ALL POOR COMFONENT5 TO CONFORM TO LAHOLORV5 5TANDAR05, PAINT LANPLORO'S 51PE OF POOR & FKAME TO MATCIf ADJACENT BARRICADE. NOTE: ENSURE ALL CONCEALED WOOD AND BLOCKING TO BE FIRE RATED TREATED WOOD NOTE: ALL FINISHES INCLUDING MILLWORK SHALL BE CLASS A MATERIALS. M_F TA_UNA Architectur_c & Design PC. 1665 I IIS hwa 588 g / LIIIsvllle 9/1 M5 3 37 -1 EL 601.914.6909 FAX 601,763.4886 www, M E-FALU NAarchi tects.corn email: rTletalunaa�mindsprin.com THIS DRAWING AS AN INSTRUMENT OF SERVICE I L S AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING OR ANY REPRODUCTION THERE OF WITHOUT THE EXPRESS WRITTEN PERMISSION I N OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION I N DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 m C� T I Tlop_ A it uy ii `� � �. (fl` ' , '��••'• �lf'L.L� V��j C•• / •-- ®®. _ _ � � II TUI II `_Jn� I II III II ' 1 � � / ' v -f' ``v";, %r..�"�j1:�'_;''�:•.... �' - __ 6 08 A5.0 - ray ,,a., �X-f' _ •• ( A5,U I II III, II , - �,,,' •- I - I - I • 'l r I II IIII II , , /,��� = ry'.`::`.`.•.•• ,/ ._-__.. _ "___" I II IIII II / , �'b ,< '•�• t.. •,. ' I II IIII II / / •�, � � _ OUT LET F0 TV t. N I OUTLET FGR. VIDEO_ '`~,� Ir' I 1 ➢i III II / r �j, IIII II oCE55oK uNIT I I, I II IIII II A2,G • ,' / II t _ 1 I II IIII II ,' ' n II III; II Hudson Booksellers IEI D ; 1 �i HOKZ, ' IN BA5E AIRPORT TERMINAL � , J Lry�I ELECTRIC FANEL, _r rl •',I ' , TELEPHONE BOARD, \ I IIII II ,' (�(Cor`flAGroK 5wrrcH � \ I II IIII II / / 36" HIGH x 36" (MIN.) WIDE \�dy_ LINE OF EXISTING HANDICAFFED-ACCESSIBLE \ 51GN 5HE1_F ECGUN'rEr\IOr ' O F (T`(F 5I -TAPED) ABOVE TO REMAIN \ II IIII II/ \ L/L_JII __j -_I14 II A2.0 / '---------- _.----- ---------- II IIII II / / 11 11 ry �^-___-7�;<,�, ♦_ \\ \ I II IIII II / / I II II II 11 `�---J I II IIII II / I II II II I � ,� L _l l _ _1111 i =__ - _- ___� I 1 I/ �`1:�__'I�IW�'-�I ,�;I rrll I I W 1 -�`_' I ' '' '' (f II III II f•- I (-____----__, r- I it ^ i 1---------- I I v I I_07I II II 11 II II I I 11 I j II , LLI NEW EASE SPACE r- (\/ �\/\ , ADDI ION ;.,I Ali I 36" HIGH x 36" (MIN.) WIDE G HANDICAFFEU-ACCE551BLE A2,U I COUNTERTOP ('IYf' 5rIAPED) I 1 II ii HORZ,p I n IN BA5E Hudson News I 11 I u OUFLEX MOUNTED IN I u MILLWOKK 0,104" AFF / A2.0 (TY!". UNLE55 OTHERWISE / 1 NOTED) / A / � n I II A2.G / L / DUPLEX FOR COOLER , MTD. IN FAKTITION , 1 I I ' I,.IGCCCKQZ. i ir-----///- \-___-11 Ir----/ -- ---moi i; ---------- I -------- L_ �' IL15L I II ( J ) n I / O� II 11 II I / I A3.0 -'I a`I --_ -JI--_-_ -'-- I II v II \��-// II II I IL, I s� _ 15: �^• . `�1 II II II Imo---------- L =[^' '-I II I II I I I 11 11 it 11 11 ,{ 'I I (I I I' I I I I III I -1\J 1T �rL---------- '--------- (5 ---------- I IL--------- -II IL--------- II I (hi ��I d j- I NO. DATE REVISION I :r..: ...\tet ................................................. . .::::.::...:::.............. .::.:.. ..............::.>:.;.:... ..::::. V A IF \\ AFN . 7.7.71 f.. f.. THIS DRAWING AS AN INSTRUMENT OF SERVICE I L S AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING OR ANY REPRODUCTION THERE OF WITHOUT THE EXPRESS WRITTEN PERMISSION I N OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION I N DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 m C� T I Tlop_ A it uy ii `� � �. (fl` ' , '��••'• �lf'L.L� V��j C•• / •-- ®®. _ _ � � II TUI II `_Jn� I II III II ' 1 � � / ' v -f' ``v";, %r..�"�j1:�'_;''�:•.... �' - __ 6 08 A5.0 - ray ,,a., �X-f' _ •• ( A5,U I II III, II , - �,,,' •- I - I - I • 'l r I II IIII II , , /,��� = ry'.`::`.`.•.•• ,/ ._-__.. _ "___" I II IIII II / , �'b ,< '•�• t.. •,. ' I II IIII II / / •�, � � _ OUT LET F0 TV t. N I OUTLET FGR. VIDEO_ '`~,� Ir' I 1 ➢i III II / r �j, IIII II oCE55oK uNIT I I, I II IIII II A2,G • ,' / II t _ 1 I II IIII II ,' ' n II III; II Hudson Booksellers IEI D ; 1 �i HOKZ, ' IN BA5E AIRPORT TERMINAL � , J Lry�I ELECTRIC FANEL, _r rl •',I ' , TELEPHONE BOARD, \ I IIII II ,' (�(Cor`flAGroK 5wrrcH � \ I II IIII II / / 36" HIGH x 36" (MIN.) WIDE \�dy_ LINE OF EXISTING HANDICAFFED-ACCESSIBLE \ 51GN 5HE1_F ECGUN'rEr\IOr ' O F (T`(F 5I -TAPED) ABOVE TO REMAIN \ II IIII II/ \ L/L_JII __j -_I14 II A2.0 / '---------- _.----- ---------- II IIII II / / 11 11 ry �^-___-7�;<,�, ♦_ \\ \ I II IIII II / / I II II II 11 `�---J I II IIII II / I II II II I � ,� L _l l _ _1111 i =__ - _- ___� I 1 I/ �`1:�__'I�IW�'-�I ,�;I rrll I I W 1 -�`_' I ' '' '' (f II III II f•- I (-____----__, r- I it ^ i 1---------- I I v I I_07I II II 11 II II I I 11 I j II , LLI NEW EASE SPACE r- (\/ �\/\ , ADDI ION ;.,I Ali I 36" HIGH x 36" (MIN.) WIDE G HANDICAFFEU-ACCE551BLE A2,U I COUNTERTOP ('IYf' 5rIAPED) I 1 II ii HORZ,p I n IN BA5E Hudson News I 11 I u OUFLEX MOUNTED IN I u MILLWOKK 0,104" AFF / A2.0 (TY!". UNLE55 OTHERWISE / 1 NOTED) / A / � n I II A2.G / L / DUPLEX FOR COOLER , MTD. IN FAKTITION , 1 I I ' I,.IGCCCKQZ. i ir-----///- \-___-11 Ir----/ -- ---moi i; ---------- I -------- L_ �' IL15L I II ( J ) n I / O� II 11 II I / I A3.0 -'I a`I --_ -JI--_-_ -'-- I II v II \��-// II II I IL, I s� _ 15: �^• . `�1 II II II Imo---------- L =[^' '-I II I II I I I 11 11 it 11 11 ,{ 'I I (I I I' I I I I III I -1\J 1T �rL---------- '--------- (5 ---------- I IL--------- -II IL--------- II I (hi ��I d j- I NO. DATE REVISION I 2-22-09 TENANT REVISIONS A OUTLETFUK FUTURE COOLER I l � 29'-0" EXI5TING WALL - FIELD VERIFY R CONSTRUCTION FLAN 1/4'1:= 1"0. Hudson News - Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFO RD O INTERNATI NAL AIRPORT S FLORIDA ANFORD a E NOTE: AFTER DEMOLITION, GC AND MILLWORK CON'rKACrOK 5HALL MEA51LIKE AND VERIFY 5FACE DIMEN51ON5 AND LOCATION AND 51ZE EXI5TING NICHES FOR MILLWORK CLEARANCE REQUIREMEHT5 FRIOR'r0 cON5-rRucrloN DRAWN DATE 12 -1 -Ob 0 CHECKED JOB NUMBER 0614 CONSTRUCTION PLAN FLOOR MATERIAL NOTES TEMPLATE NOTE: FLOOR TILE INSTALLATION TO DE LEVEL WITH NO MORE THAN 1/16" VARIANCE IN HEIGHT. G.C. SHALL FIELD VERIFY CONDITION OF FLOOR FOR LEVELNESS AND/OR 1MFERFECTION5 PRIOR TO 50MITTING DID. 1665 Highway 588 TILE TO DE THIN-5ET. GROUT JOINTS TO DE '10' WIDE (MAX.) :. ,. ALL TRAN5rnONS DE-FWEEN TILE AND EXISTING FLOOR AREAS WITH ABOVE SHADING INDICATES FOOTFKINT MATERIALS TO DE FLUSH AND SMOOTH, OF NEW MILLWOKK/FIXTUR.ING THAT DOES NOT RECEIVE FLOOR TILE. THE G.C. AND MILLWORK CONTRACTOK(5) PATCH ANY FLOOR FENETRN'ION5 NOT BEING RE -USED TO SHALL COORDINATE WORK TO INSURE FROFER FIT OF MATCH EXISTING CONSTRUCTION. MAINTAIN FLOOD; ALL MILLWORK/FIXTURING WITHIN TENANT'S SPACE FIKE-KATING5. FRIOK TO ANY FADRICATION AND INSTALLATION. THE GC SHALL CLEAN, SAND, FKEF AND FKIME SLAB PER MILLWORK CONTRACTOR SHALL INSTALL TEMPLATES STONE TILE MANF. 5FECIFCATIONS FKIOR TO APPLYING OF THE MILLWORK/FIXTURING 50 THAT THE FLOOR TILE MEMDKAME. MAY DE IN5TALLED TO THE TEMPLATES. NO GAPS DE TWEEN FLOOR TILE AND MILLWORK/FIX-rURING SHALL PROVIDE EPDXY INJECTION •TRE/ATMEN-r FOR. CRACKS -THOSE REMAIN ONCE ALL WORK HAS DEEM INSTALLED, COMPLETELY THROUGH THE SLAB AND FROM 0.0625 INCH UP TO 0.25 INCH IN WIDTH. ECD MEMBKANE, SELF-ADHEKING ELA5TOMEKIC SHEET, 40 MILS THICK AS MADE DY N.A.C. PRODUCTS, AKRON, OH, OR ARCHITECT ACCEPTED EQUAL. APPLY STONE FLOUR. SEALER FEK MANF. RECOMMENDATIONS. MIRACLE SEALANT 511 IMFKEGNATOK FOR SEALER AND 5LIF RESISTANCE. it LEASE LINE LANDLORV5 EXI5TING FLOORING OR ADJACENT TILE NEW 5TOF:E TILE - MAX VARIATION 6E•}'WEEN FINISHED FLOOR i 5URFACE5 TO DIE -1/16" ®EVIL FULLSCALE EXI5TING CONC. FLOOR- G.C. SHALL GRIND AND OR FEATHER 5LAD IF REOWIRED TO ALLOW FLLJ SH IN51-AI_LATION OF NEW TILE WITH CONCOUK5E FLOORING. SLOPE 5HALL NOT EXCEED 1/6" IN ONE FOOT OF RLJ N (TYPICAL) EDGE -PROTECTION TRANSITION PROFILE A5 MFD. 5Y "5CHLUT ER" -MODEL. "'Ll 5CHLUTER- 5CHIENE" FINI51-1 TO BE 5ATIN ANODIZED ALUMINUM #AE 125 VERIFY EXACT HEIGHT REUT) PKIOK TO ORDERING. ORDER "R" WHEN U5ED FOR RADIU5 APPLICATIONS ALIGN TOP5 OF TILE TO TILE OR TILE TO WOOD EX15-TING CONC. FLOOR- G.C. 5HALL GRIND AND OR FEATHER 5LAD IF REOUIRED TO ALLOW FLUSH INSTALLATION OF NEW TILE EDGE -PROTECTION TKAN5ITION PROFILE A5 MFD. 13Y "5CHLIJT EP. 5Y5TEM5" -MODEL " 1.1 SCHLUTER- 5CHIENE" FINISH TO 13E 5ATIN ANODIZED ALUMINUM #AE 125 VERIFY EXACT HEIGHT REQ'D PRIOR TO ORDERING. ORDER "R" WHEN U5ED FOK RADIUS APPLICA-TION5 DETAIL FULL SCALE METALJN A ArchiWcrure & Design P.C. F 1665 Highway 588 :. ,. �- Ellisville MS 39 }37 ,\ ..����� . ..., . �. . : 'f: f TEL 601.9 14.6909 FAX 601.763.438 6 RMOMti\ \\� gm —aw :.:::......: Aff .... \... ft es AMR ww w M ETA L JNA r I ec a ch t is co m :.. ...:..::::::::::::.:...;.;.:.:...:....... 3 e_rnl; c- a I _ _om til una nin J, Tin - THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THEREOF, WITHOUT ITHOUT THE EXPRESS WRITTEN PERMISSION C OF THE DESIGNER ISTRI TLY 5 C PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION O IN DEROGATION OF THIS ARCHITECTS C S RI GHTS. COPYRIGHT 2008 CORE DRILL. PENT RATI( POWER, DATA, AND TE UNDER CA5HWRAF. D AND VERIFY EXACT RE, PLACEMENT IN THE FIE GENERAL CONTRACTO X -KAY THE FLOOR 5LA ANY CU'TT'ING, DRILLIN, OTHEK PENETKA'nONS PORT PRIOR TO X-RAY. NO. DATE REVISION FLOOR MATERIAL PLAN • Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVE_ ORLANDO SANFORD INTERNATIONAL AIRPORT SANO F RD FLORIDA DRAWN DATE 12-1-08 CHECKED JOB NUMBER 0514 FLOOR MATERIAL PLAN [0 14; [W I illi 1� 1. ALL LANDLORD'S EXISTING CEILING FIN15HE5 TO REMAIN, UNLESS O-THERWISE NOTED. ANY AREAS DAMAGED DURING CONSTRUCTION SHALL BE REPAIRED/REFLACED TO MATCH EXISTING. 2. G.G. TO VERIFY THAT EXISTING STRUCTURE, pUC'TWORK, EQUIPMENT, ETC. DOES NOT INTERFERE WITH NEW FINISHED CEILING HEIGHTS SHOWN ON CEILING FLAN. G.C. TO NOTIFY TENANT'S KEFKESENTATIVE IMMEDIATELY( IF FINISHED CEILING HEIGHTS ARE NOT ATTAINADLE, 3. ARCHITECTURAL DRAWINGS SHALL GOVERN THE FLACEMENT OF ITEMS (LIGHT FIXTURES, DIFFUSERS, ETC.) EXPOSED TO VIEW. 4. ALL DIFFUSERS AND GRILLES -TO DE'WHI-i'E' TO MATCH ADJACENT CEILING COLOR UNLESS NOTED OTHERWISE. THE GC SHALL VERIFY AND ORDER ALL DIFFUSERS AND GRILLES FRAMES TO COMFATIDLE WITH THE CEILING TYPE IN WHICH EACH 15 INSTALLED, 5. LAY- IN CEILING HANGER WIRES 1-0 DE 9 GA. SOFT ANNEALED MILD STEEL. WIRES SHALL NOT 1 E ATTACHED TO ANY DUCTWORK, FLUMDING, OR CONDUIT, CONSTRUCTION TO MEET ASTM C655 AND ASTM C636. 6. THE G.C. SHALL DETERMINE THE NUMDEK, LOCATION, AND SIZE OF ANY ACCE55 FANELS REQUIRED IN GYF DD. CEILINGS. THE ARCHITECT SHALL APFROVE TYPE OF ACCESS PANEL FRIOR TO INSTALLATION, LIGHT RX"I"URE SCHEDULE SEE COMPLETE LIGHT FIXTURE SCHEDULE ON SHEET Ea1.0 NO. SYMBOL DESCRIPTION 2 X 2 RECE55EO FARADOLIC LOUVER 131 FLUORESCENT LIGHT FIXTURE, 9 CELL 2 X 2 RECESSED FARADOLIC LOUVER 131 EM FLUORESCENT LIGHT FIXTURE, 9 CELL WITH SELF CONTAINED EMERGENCY BATTERY PACK, TEST SWITCH AND INDICATE LIGHT F1R Zi O 6" LINE VOLTAGE COMFACT FLUORESCENT RECESSED FIXED DOWNLIGHT W/ WHITE BAFFLE LINEAR FLUORESCENT TS ARCH. 01 FIXTURE W/ INTEGRAL BALLAST AND FOWER CORD & FLUG ('15 5/31) 02 LINEAR FLUORE5CENT T5 ARCH, FIXTURE W/ INTEGRAL BALLA5T AND POWER CORD & FLUG (24 5/51) 03 LINEAR FLUORESCENT TS ARCH. FIXTURE W/ INTEGRAL DALLA5T AND POWER CORD & FLUG (36 5/51) 06 LINEAR FLUORESCENT TO ARCH. FIXTURE W/ INTEGRAL DALLAST AND FOWEK CORD & FLUG (751/4"L) ® ARCHITECTURAL EDGE -LIT X1 EXIT SIGN NOTE; ALL LIGHT FIXTURES SPECIFIED ARE TO BE PURCHASED BY THE G.C. THROUGH THE TENANT'S LIGHTING CONSULTANT e CHARLIE. AND COMPANY, CONTACT VIRGIL @ (309) 605-5043 NOTE. LIGHTS MUST RE PREPAID BEFORE DELIVERY THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 51 51 cc PI E> Lc CEILING Ir LAN 1/4" =1'-O" ADJACENT RESIAURAN I Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA 11AIN 1 FKOFILE OF'06' LIGHT FIXTIJKE FKOFILE OF'06' LIGHT FIXTURE FIRE ALARM 5TKODE MILLWORK "ro DE MADE REMOVABLE FOR FUTURE COOLER (SHOWN 5HAPED) CORNER TRIM FLJ REGIONAL MURAL 5'( I F -Z.1 AHICOM 51GH5 - MOUNT ON FFL2 COVEKEP PANEL DY MILLWORK coNrrKACrOK f:FC;10HAI2• 4UKAL DY ANICOM 51GH5 ROMEWill IIS! KF�IONAL �, (MURAL EKY ANICoM 51GN5 WD1 ,— tvFr2 v v LEXAN FAN'EL5 FOK v MAGAZINE COVERS MOUNT PUFLEX KECEFTACLE5 0 101" A.F.F . — -- —CATEGORY - — - --; — 51 G N AG E77 -- - -- ------ WP1 TO --. - II I --CORNER TRIM — LJ -- Ll L o II II ► , 100 I I YlU I_ IIU I J 103 I� 5LATWALL DISPLAY 'I I OPEN FACE COOLER I OPEN FACE COOLER ~I 5LATWALL (REMOVAPLE) DI5PLAY RECEFTACLE AELEVATION MOUNTED YF) IN BASE (�r(F) DISPLAY DISPLAY DISPLAY DI5PLAY RECEFFAGLE ELEVATIONMOUNTED HO IN BASE (-r([')) 3/511 R 11-011 2 2 GRAPHIC BY ANICOM F-4.2 51GN5 - MOUNT ON F-4.2 FL2 COVERED FAHEL BY MILLWORK CON"rKACFOR r l f l r I r l —.-.---..._. - -. --. r _ I I C, I I 5FINNEK5 -ct-t I - 1I I it It I -- --- �) 5L2 5L2 WDZ .. I I ------.---_ it I I �5 L J l J l J L I -- JJ2 -__ L II I I 151 I I 16U I 16'I I h ROOKS PAPYRUS PAPYRUS F ELEVATION 100 5LATWALL DI5PLAY G REGIONAL MURAL FAY RLWO F-3.0 AWCOM 51GN5 - MOUMr ON IIKK FL2 COVEKEP FI,NEL DY SOFFIT MILLWORK CONTRACTOR I I I I I I I I I I 1 rl rl I II II II II I II II II II I I I F�I Ci l'I I II II II II I II II II II I II II II � II I II II II II I II II II II I II II � II II I I I I W01it- I I I II II II II I II II II �II I II II II II I Ir— J L 1 L J FL1 L J L I I I � I I I 1�F1 I Igo I loll I 140 GIFTS GIFTS GIFTS GIFTS THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 n II II II II II II II II II II II II It i --J II II II II II II II II II N II II Ll 2 -L-i 103 5LATWALL DI5PLAY MOUNT PUFLEX KECEFTACLE.S FKOFILE OF'02' OF' '03' LIGHT FIXTURE (-r(F) PROFILE OF'OF5 LIGHT FIXTURE ("rYF) RECESSED UITANPAKP HALF -ROUND Ivl'rl HALF-ROIINP FROFILE OF '03' LIGHT FIXTURE FKOFILE OF'06' LIGf1"r FIXTURE (rrF) KECEF"f'ACLE — MOUNTED HOKIZ. IN DA5E (1-(F) NO. DATE REVISION 1 2-22-09 TENANT REVISIONS ELEVATION aJ/811 � 11„0,1 MOLMT PUFLEX KECEf TACLE5 0104'' A,F.F —CD2 CATEGORY — _ 510NAGE — =� �5L2 7v HALF -ROUND EXI TING 5OFFIT- FKEF FOR FAINT F1 _ WD1 N LD `- ri i GLI II I I Ili (5L1 = I � ELEVATION aJ/811 � 11„0,1 MOLMT PUFLEX KECEf TACLE5 0104'' A,F.F —CD2 CATEGORY — _ 510NAGE — =� �5L2 7v HALF -ROUND EXI TING 5OFFIT- FKEF FOR FAINT F1 _ � N LD `- i 1_ J GIFTS ��' ENCLOSURE �I Cj ELEVATION 3,811 � 11_011 R TRIM F-2.0/ `F-2. NON -ILLUMINATED 51GNAGE FY ANICOM 51GN5 MILLWORK 5OFFI f PROFILE OF 0'1 LIGHT FIXTURE (-r(F) IIII - II II COKNEP TKIM --m OFEN _ 5L1 II —` 1 L J it I 1U0 _ I 120 I 552 I 5LATWALLNIS- EWS`� DI5PLAY TOWER ELEVATION 3/811 .+ 11-011 OFEN EX CORNER 1 KIN( r< 2 LOCAL AUTHOR GRAFHIC BY F-1%0 ANICOM 51GN5 - MOL1N,r ON 19L2 COVERED FANEL 13Y MILLWORK CONTRACTOR II IIII II IIII II IIII II IIII II IIII II IIII II 1111 II IIII II IIII I I WU2 I I I II IIII II IIII II IIII II IIII II IIII II IIII II IIII II IIII II IIII II IIII II IIII cc��) I I JJ2 I I I I L1 LIL1 lel BOOK5 ELEVATION 3/811 11-011 Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD �c�2DSo INTERNATIONAL AIRPORT SANFORD, FLORIDA !-�.�.� ZL DRAWN DATE 12-1-06 CHECKED JOB NUMBER ELEVATIONS M FTAI_U NA Architecture & Design P.C. 1665 Highway 588 Ellisville, MS 39,137 TEL 601.9 14,6909 FAX 601.763.4886 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN 'rHE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. www. M ETALU NAarchitects,cor n email: metalunact rnind5pring.com ;< COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 TENANT REVISIONS 1l:I�VN►1 CHECKED Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN UAI r 12-1-06 JOB NUMBER 0814 ELEVATIONS TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL_ AIRPORT SANFORD, FLORIDA - . r ADJACENT 5TORE5 `9 MATERIAL TO REMAIN THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN. 'rHE PROPERTY OF ARCHITECT., USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION.OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 WOOD FANEL5 OVER EXI 5TING CURVED 5OFFrr EX15-TING AIRPORT CEILING AND 50FFrr O - SLUE PAINT EU WAVES r�� i YP 2 EX15TING 55 CURVED 510N REVISION 1 � c9 w c, t M15 rYR LEDGE -r0 REMAIrl INDIVIDUAL LE-rTER LEE) FW� Tyr. MOUNTED 51GN ON EXISTIHOi mi " w - THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN. 'rHE PROPERTY OF ARCHITECT., USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION.OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 WOOD FANEL5 OVER EXI 5TING CURVED 5OFFrr EX15-TING AIRPORT CEILING AND 50FFrr O - SLUE PAINT EU WAVES r�� i YP 2 OFEN CORNER 'TRIM H FRONT ELEVATION 3/8" = 1'-0" HON-ILLUMINAT EU SURFACE MOUNTED 51GNAGE - T YR OF ALL 5 - 51GN5 DY AHICOM F5 T YF CORNER TRIM r e p7 r Ivli .� .� �•: - 4s o l UF:AL MAI LE :'v:}sr?1r "! ; =<:: > fa ::.:R "• !4°?' :r'<' VENEER, I `(I' - L� "`.^R YFf� T nrJ�\^',.��✓j '�..,�.+`-.:,.-.,.:., fr'; `+1k...; +.iF-'"+'n::.: - '"`�i.-' �i�.-,{''f'.-..-�`+r��.��,�•':!.:##;.;,gF�cr:�.F-�%. 1{�::r:;r-" OPEN TO 5"TORE f;LUE PAINT EU VVAVE5 P5 CORNER TRIM � SIDE ELEVATION A,, 3/811 = 1 1-011 NO. EX15TING 55 CURVED 510N REVISION 1 2-22-09 TENANT REVISIONS rum. vhIMW M15 rYR LEDGE -r0 REMAIrl INDIVIDUAL LE-rTER LEE) FW� Tyr. MOUNTED 51GN ON EXISTIHOi mi " l'IJRVED SIGN 50FFri= SIGN FAY ANICOM 51GN5 55 5HROUD OVER FLA"r PANEL AV1 u - ? o 015FLAY FEAT-IJRE MAO FROGRAM OFEN CORNER 'TRIM H FRONT ELEVATION 3/8" = 1'-0" HON-ILLUMINAT EU SURFACE MOUNTED 51GNAGE - T YR OF ALL 5 - 51GN5 DY AHICOM F5 T YF CORNER TRIM r e p7 r Ivli .� .� �•: - 4s o l UF:AL MAI LE :'v:}sr?1r "! ; =<:: > fa ::.:R "• !4°?' :r'<' VENEER, I `(I' - L� "`.^R YFf� T nrJ�\^',.��✓j '�..,�.+`-.:,.-.,.:., fr'; `+1k...; +.iF-'"+'n::.: - '"`�i.-' �i�.-,{''f'.-..-�`+r��.��,�•':!.:##;.;,gF�cr:�.F-�%. 1{�::r:;r-" OPEN TO 5"TORE f;LUE PAINT EU VVAVE5 P5 CORNER TRIM � SIDE ELEVATION A,, 3/811 = 1 1-011 NO. DATE REVISION 1 2-22-09 TENANT REVISIONS 51AINLE55 STEEL. Hudson News - Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA HEVV GYP b[), OVER EXI51INO -- FAINr'ED1<) MATCH EX15T1NG ADJACENT AIRFORT AREA5 1 NEW r)A5E TO MATCH LANDLORV5 EX1511N0 0 2 DETAIL 3 A3.2 1�(P 111=11-011 ! CENTERLINE OF 51UE-FOLDING GRILLE 5 DETAIL THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 DU51 PROOF STKIKE A5 REOL11KED DY GRILLE MANF, (1-'(F) TWO 2 Wb" 'TWIN BALL CA"IGH A5 MANF, BY HAFELE MODEL#244,20.120 WUI P5 5IDE FOLDING GRILLE - VERIFY FOCKET [)EFTH AND EXACT MODEL T (FE EXISTING COLIJIvII`I/ ENCI.05UKE 61, �UD1 NI"l3 MT3 ------------------- ------------------- WO 2 3/0" JVVIN DALL. C CH A5 MANF. B`( WDI #12L}LLL)Ni� DEL �t 0 DUST -PROOF STRIKE A5 REQUIRED DY GRILLE MANF. (TYP) CENTEKLI�IE OF 5IDE-FOLDING GRILLE Cn (rYF) CONT. CONCEALED LEAF _ HINGE #21265A, DY ROTON - VEKIFY FIN151-1 WITI1 ARCHITECT N 140 141 \ bVD1 PROFILE OF GYF FSU. 50FFIT' ABOVE RECE55ED STANDARD (lYF) --------------------------------------------------------- l PROFILE OF CROWN MOLD 3„ 3 ADOVE A'- 2 c% c,tirr3 � ----------------------------------------------- \4 C 400 DETAIL v=11. -O., 0 �n �O AVI O / RECE55EU -161 5-IANDARU (-r(P) 140 1_ --------------------- ------ WD2 ' FROFILE OF CROWN MOLD 4UD 1 ABOVE PROFILE OF WD2 FIELD VERIFY 5OFFFr ABOVE , 5 [DETAIL NO. REMOVADI_E 1 MILLWORK °'� FIELD r.VER:IFY I 1-7 2-22-09 TENANT REVISIONS NO SED 5 _ WD1I (�v 6DI IN COORDINATE AVI I115TALLATION AND DUPLEX OUTLET LOCA-rION5 FILLER: WITH TENANT'S REFI 1 �O AVI O / RECE55EU -161 5-IANDARU (-r(P) 140 1_ --------------------- ------ WD2 ' FROFILE OF CROWN MOLD 4UD 1 ABOVE PROFILE OF WD2 FIELD VERIFY 5OFFFr ABOVE , 5 [DETAIL NO. DATE REVISION I 2-22-09 TENANT REVISIONS Hudson News - Hudson Booksellers . Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RF -TAIL SPACE_ IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA 100 NT 5 DETAIL 111 .+,1^011 MT3 (E ALL 50135 EXISTING COLUMN/ ENCL05UKE DU5TFKOOF 51'KIKE A5 REOUIRED DY GRILLE MANF. ('r -(F) CENTERLINE OF 5IDE-FOLDING GRILLE (.r -(P) CENTERLINE OF 5IDE-FOLDING GRILLE (-f (P) DIJ5TFR00F rRIKE A5 RE01-JIKED BY GRILLE MANF. (T -(f) 7 A3.2 •fWO 2 3/5" TWIN DALL CA' A5 MANF. FSY HAFELE NI O D E L // 2zI /l .20.12O W 0 w Nal 511)E FOLDING GRILLE - VERIFY POCKET DEPT H AND EXACT MODEL'TYFE EXISTING COLUMN/ ENCLO5URE DRAWN DATE 12-1-08 HECKED JOB NUMBER U81�T STOREFRONT PLAN DETAILS • �l M ETAI_U NA Architecture & Design P.C. 1665 Highway 588 Ellisville, M5 39437 TEL 601.9 1 1.6909 FAX 601.763.4886 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING,. OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. www. M ETALU NAarchitects.com email metal una(c1bmindsprinG.com f COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 TENANT REVISIONS Iai 1-M11111111 111111 1117r1 1 ' Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN DRAWN DATE 12-1-oa CHECKED JOB NUMBER 0&1 21- REFRONT SECTIONS TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA M ETALU NA ArchitecLUle & Design P.C. 1665 Hiphway 588 Ellisville, MS 39437 TEL 601,9 14.6909 FAX 601.763.9886 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. www. M ETALU NAarcli i tec Ls, corn email: metal una(cbmindsprin�.corn COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 TENANT REVISIONS low Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN ICI'VV CHECKED JOB NUMBER U31> - STOREFRONT DETAILS TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL. AIRPORT SANFORD, FLORIDA A-3.2 EVISIO 5URE DRACING TO U �EFSIDE OF DECK WrrH715° LONG POGVEK-D VEN FA5TENER5 924"O -C"- N, X. ATTACH TOP & DOTTO TRACK 5 W1 (2) #6x, 7/16 - FAN HEAD 5CKEW5 ATTACH DKACI NG TO TOP T RACK W/ (3) — #6 x 7/16'' PAN HEAD 5CKEW5 EX15T1NG EX&FING 5TKUCTUKE C 5TRUCTIJKE 3 5/6" METAL 5T'U D5 \ UNISTK UT @ 46" 0.C. UNarm G 46" O.C. 5ECURED TO 5ECURED l0 5TKUC rUKE 5TKUCTUKE AGOVE r ADOVE_______ _ ---------------- --------- p------------ ---------------- --- ------------- 3" x 3" x'1/4�" x 2" LONG /// 3" x x 1/4-" x 2" LONG 5TEEL ANGLE 5T F L ANGLE 3" x 3" x 3/6° FLUOR. STRIP 5TKAP HANGER E)TKAP HANGER FIXTURES FASTENED TO FA5TENED TO 1/4�" DIA. GALVANIZED 5TEEL 5TKUC'rURE iii 5TKUCTUKE HANGER KOD5 00 zI-5" O.C. MAX. E2 P2 SUSPELI510N CHANNEL LU NOT USED I C 48" O.C. MAX. WIFE CLIP #9 SPRING .5TEEL CU5TOM ALUM. FRAME WITH COLORED OK PATTERNED ACRYLIC ( PANELS A5 MANF, G`( \ FURRING ANICOM 51GN5- COOOD. CHANNELS EXACT SOFFIT 5HAFE 0 24" C.C.' WITH 51GN 5HOP 1 UFAWING T'EMPLAT LAY -IN CEILING 5/8 T(FE X 2'-0" GYP 131). DETAIL DETAIL THRU LAY -IN CEI _ _ LING 11/2" =1'-O" DETAIL DETAIL THRU GYP. BD. CEILING DETAIL 11/2" =110" 1'-0" _\ A A A 1 1/2"= THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 TENANT REVISIONS m 5ECUKE 5RACING \ UNI5r- 'i 5ECUKED TO UNDEK50E OF DECK _z TO I Cr, 0 24" OC WITH MIN, 7/6" LONG POWER-DKIVEN FA5, 7NEK5 0 24" O.C. MAX. 1/4" DIA, GALVANIZED 51 -EEL HANGER KOD, J'-0" AFF LED FLEX IDLE STRIP COVE LIGHTING ON METAL 5-rUD DLO(: A5 GYP. DD. SOFFIT REM) GY ANIC 1 -PAINT P2 51GN5- COLO : WHITE 2 TAIL 1 1I2 =1 a-®ee hNDER5IDE OF EXI5TING DECK ATTACH TOP & DOTTOM T KACK5 W/ (2) 97x'1116" PAN HEAD 5CFEW5 ATTACH DRACING TO TOP TRACK W/ (3) // 7 x 7/16" I'A N 1-1 EA I) 5CKEW5 NOT USED VERTICAL & ANGULAR GRACING V 4b'' O.C. MAX. - DRACING 51ZE & GAUGE TO DE EQUIVALEHTTO5TUD 9'-6" AFF LED FLEXIDLE 51 COVE LIGHTING ON METAL 51 IJD hL.00Y A5 REM) DY ANICOM 51G1\15- COLOR WHITE 0 �rkr ----- ---._. -0" AFF C YI'. DD. 5OFFIT N'f F2 1'-0" FIRE CAULK A5 REM) TO UNDER5IDE OF DECK TO MAINTAIN ONE HOUR FIRE EATING 5ECUKE GRACING TO IJNDEK5IDE OF DECK WITH MIN. 716" LONG POWER - DRIVEN FA5TENEKS Ca 24" O.C. MAX. VERTICAL & ANGULAR DRACING C60 46" O.C. MAX. - DRACING 51ZE & GAUGE TO 13E EQUIVALENT TO 5TU D RE'FEK'r0 CON5•rKUCrION DRAWING5 FOR CEILING HEIGH'r & TYPE I � I I I I � r� 5/8" T`(PE'X' GYP DD. I � I - I 3 516", 20 GA. METAL 5TUD5 0o 16" O.C. TOP & GOTTOM TKACK 51ZE & GAUGE TO GE EQUIVALENTT•0 5TUD5 5ECUKE BOTTOM TRACK 21-01' I 0 _ ATTACH TOP & DOTTOM MINILI 25/4" LONG PO WER- rRACK5 W/ (2) #7 x 7/'16" DRIVEN FA5TENER5 C PAN HEAD 5CREW5 24" O.C. Hudson News - Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DETAIL NON -RATED NON -REARING PARTITION 1"=V-0" 1 Ca) 46" O.C. MAX. WIFE CLIP' #9 5FRING 5TEEL ATTACH TOP & Dar rOM T KACK5 W/ (2) #8 x 7/16'' ' FURRING CHANNELS< PAN HEAD 5CKEW5 0 24" O.C. 5U5PENSION CI�IANNE Cal 4 b" O.C. MAX. f\ VEK,rICAL & ANGULAR 4 CjKACING (0 46" O.C. MAX. L3KACIf JCi SIZE & �iAUGE .. TO GEEQUIVALENT TO 5'ru D NOT 1 4m. USED- ­ 10'- 1" AFF ` ( ATTACH C3KACING TO �2� TOP TRACK W/ (3) o #5REWS PAN HEAD J'-0" AFF LED FLEX IDLE STRIP COVE LIGHTING ON METAL 5-rUD DLO(: A5 GYP. DD. SOFFIT REM) GY ANIC 1 -PAINT P2 51GN5- COLO : WHITE 2 TAIL 1 1I2 =1 a-®ee hNDER5IDE OF EXI5TING DECK ATTACH TOP & DOTTOM T KACK5 W/ (2) 97x'1116" PAN HEAD 5CFEW5 ATTACH DRACING TO TOP TRACK W/ (3) // 7 x 7/16" I'A N 1-1 EA I) 5CKEW5 NOT USED VERTICAL & ANGULAR GRACING V 4b'' O.C. MAX. - DRACING 51ZE & GAUGE TO DE EQUIVALEHTTO5TUD 9'-6" AFF LED FLEXIDLE 51 COVE LIGHTING ON METAL 51 IJD hL.00Y A5 REM) DY ANICOM 51G1\15- COLOR WHITE 0 �rkr ----- ---._. -0" AFF C YI'. DD. 5OFFIT N'f F2 1'-0" FIRE CAULK A5 REM) TO UNDER5IDE OF DECK TO MAINTAIN ONE HOUR FIRE EATING 5ECUKE GRACING TO IJNDEK5IDE OF DECK WITH MIN. 716" LONG POWER - DRIVEN FA5TENEKS Ca 24" O.C. MAX. VERTICAL & ANGULAR DRACING C60 46" O.C. MAX. - DRACING 51ZE & GAUGE TO 13E EQUIVALENT TO 5TU D RE'FEK'r0 CON5•rKUCrION DRAWING5 FOR CEILING HEIGH'r & TYPE I � I I I I � r� 5/8" T`(PE'X' GYP DD. I � I - I 3 516", 20 GA. METAL 5TUD5 0o 16" O.C. TOP & GOTTOM TKACK 51ZE & GAUGE TO GE EQUIVALENTT•0 5TUD5 5ECUKE BOTTOM TRACK 21-01' I 0 _ ATTACH TOP & DOTTOM MINILI 25/4" LONG PO WER- rRACK5 W/ (2) #7 x 7/'16" DRIVEN FA5TENER5 C PAN HEAD 5CREW5 24" O.C. Hudson News - Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DETAIL NON -RATED NON -REARING PARTITION 1"=V-0" 1 T- --:1- _ - - /J-/ Y 190 X67 ` :1-10 4n — r KIDD �3rj l r _-__ l b Q:E] 4 I Hudson Booksellers // /l l ::::J:::/ 13(30' / // � -----_...::......... � 375 I LI] 300 . app 4— / _ / 1 151 190 1 / 1 1TAN — — — - - 300 _ I 230 3 POS I • o ; CASHWRAP I o II I _ 1 CLI F] 300 I -- l DVD �I \ GONDOLA Hudson News ( 300 300 30U ....`:: / `300I `� --- CMILLWORKER TO VERIFY WITH TENANT REP. ANY FIXTURES THAT ARE EXISTING AND NOT REQ'D o � / ----.----------------------------------- lU0 000: e '110 '1 '10 _- `n 103 '100 �j '103 rY � H I I c� 110 N .4 C% o- i l FIXTU R E PLAN HUDSON INEVIIS / BOOKSELLERS FIXTURE SCHEDULE N®. ITEM FINISH REMARKS �2 "1/2" WIDE 100 SLATWALL�DI5PL/;r ALL WOOD SHALL BE WO -1 AND SLA'T4VALL. 5L. -I SEE DETAILS -SHEET F-2.0 51" NIDE 103 SLA'TWALL DISPLAY ALL WOOD hl -TALL UE BUD -"1 AND 5l_Ar4VALL SL=1 SEE UE -TAILS - SHEET E-2,0 f�EF'RIG. CASE ALL WOOD SHALL BE WD -1 SEE DETAILS -SHEET F -2."I 110 ENGL05URE 120 �1E4V5PAPER TOWER ALL WOOD SNALL DE WD -1 SEE DETAILS - SNEET F-2,2 ELEC''rRIC PANEL DOOR / ALL WOOD SHALL BE WD -1 AND 5L-1 SEE DFlrll_5 - SNFFT F-�.l 130 SLATWALLUISPLAY '140 `>•8" REGIONAL GIF'r5 ALL WOOD SHALL BE 4VU-1 AND FGF -1 SEE•. DETAILS - SHEET F-3.0 DISPLAY 2=f-" REGIONAL GIF'r5 ALL 4V000 SNALL Bk WP -1 AND FCP-1 SEE DETAILS - SNEE"r F-3.0 111 UISPLA'( 150 36" BOOK DISE LAY FIXTURE ALL WOOD SHALL BE WD -2 5EE DE1%,ILS - SNEF r F-�1.0 151 42" F30OK DISPLAY FIXTURk ALL WOOD SHALL BE WP -2 SEE DETAILS - SNFEr F-�f.0 160 PAPYRUS 5I'INNER FIXT URE ALL WOOD .SNALL BE WD -2 SEE DETAILS - SNEET F-�-.2 161 PA('YRlJS DISPLAY FIXTURE ALL WOOD SHALL FE WP -2 ANP 5l_A"rWALL SL -2 5EE DEIV,ILS - SI-IEE�r f�-�.2 190 BOOKS CUSTOM ALL WOOD SHALL BE WD -2 AND SLAT WALL 5L-2 5LAT4VALL DISPLAY 230 3 POS CASN4VRAP ALL WOOD 5f -TALL DE WD -'1 AND COCZIAN SS -'1 SEE Uk�rAILS - SHEET F-2.�i AND F -2A 300 PIf�IWHEEL GONDOLA ALL WOOD SHALL BE 4VD-1 AND 5LAI�VALL 5L-1 SEE DETAILS - 5f -IFFY F-2.5 l SET IS EXIS-TING TO 6E USED 2 - :"� I�l�-WO�If"��\1=J-,L��TD-SI,A�" - - � -- - '� UNIT IS EXISTING 10 BE USED 350 MOBILE MAGAZINE UNIT EXISTING UNIT Al WATERFALL BARRICADE r0 C'�k USED PROVIDED t3Y l E'NAN r 352 MOBILE CAFIUY UFII'f EXISTING UNI�r AT WATERFALL BARFJCADE T'0 BE USED PCZUVIUEU �Y �rENANT 355 MOBILE NEWS UNIT EXISTING UNIT AT E'�ARKICADE TO BE IJSEU PROVIDED BY -TENANT . 2 SET REQUIRED TO BUILD 360 NESTED TABLE' 2 SE"r5 EXI�rING "rU BE USED ALL WOOD SNALL BE WP -1 SEE DETAILS - SHEET F-2.FJ 371 BOOK'!'ABL.E ALL WOOD SNALL BE WP -2 SEE DETAILS - 51-I�F'r F-�.l 72X3U 375 FRONT AND CENTER ALL WOOD SHALL BE WD -2 TYP. UNIT BOOK D15PLA'( UVU GONDOLA ALI_ WOOD 5{ -TALL BE WD -2 DESIGN HARDWARE -CASHWRAP N0. MFG. QTY. CAT. N0. DESCRIPTION CBM INDUS'iRIES 1 76a RHOMBUS FURNITURE FIXED CASTOR FETHERED II8II.71 7."L831 HAFELE 1 51.00.31 1 ME'T'AL FLUSH HANDLES -STEEL MATTE BLACK IIOU.4L"3.3531 244.20.120 TWIN BALL CATCH 422.88.946 PRECISION BALL BEARING SLIDES -FULL EXTENSION TYPE 1 H -SERIES HINGE HAOE(t COMPANIES 780-224HD RUTON CONCEALED LEAF HINGE WITH BALL CATCH 800.L55.3590 S'�YLMARI< 110008 TRACK HEADER 800.3L8.2�}95 0'LO FINISH COLOR 1101 78 SECURITY BUTTOM'fRACI< 020 FINISH COLOR URA4VING AVAILABLE FROM SUREWOOD T- --:1- _ - - /J-/ Y 190 X67 ` :1-10 4n — r KIDD �3rj l r _-__ l b Q:E] 4 I Hudson Booksellers // /l l ::::J:::/ 13(30' / // � -----_...::......... � 375 I LI] 300 . app 4— / _ / 1 151 190 1 / 1 1TAN — — — - - 300 _ I 230 3 POS I • o ; CASHWRAP I o II I _ 1 CLI F] 300 I -- l DVD �I \ GONDOLA Hudson News ( 300 300 30U ....`:: / `300I `� --- CMILLWORKER TO VERIFY WITH TENANT REP. ANY FIXTURES THAT ARE EXISTING AND NOT REQ'D o � / ----.----------------------------------- lU0 000: e '110 '1 '10 _- `n 103 '100 �j '103 rY � H I I c� 110 N .4 C% o- i l FIXTU R E PLAN HUDSON INEVIIS / BOOKSELLERS FIXTURE SCHEDULE N®. ITEM FINISH REMARKS �2 "1/2" WIDE 100 SLATWALL�DI5PL/;r ALL WOOD SHALL BE WO -1 AND SLA'T4VALL. 5L. -I SEE DETAILS -SHEET F-2.0 51" NIDE 103 SLA'TWALL DISPLAY ALL WOOD hl -TALL UE BUD -"1 AND 5l_Ar4VALL SL=1 SEE UE -TAILS - SHEET E-2,0 f�EF'RIG. CASE ALL WOOD SHALL BE WD -1 SEE DETAILS -SHEET F -2."I 110 ENGL05URE 120 �1E4V5PAPER TOWER ALL WOOD SNALL DE WD -1 SEE DETAILS - SNEET F-2,2 ELEC''rRIC PANEL DOOR / ALL WOOD SHALL BE WD -1 AND 5L-1 SEE DFlrll_5 - SNFFT F-�.l 130 SLATWALLUISPLAY '140 `>•8" REGIONAL GIF'r5 ALL WOOD SHALL BE 4VU-1 AND FGF -1 SEE•. DETAILS - SHEET F-3.0 DISPLAY 2=f-" REGIONAL GIF'r5 ALL 4V000 SNALL Bk WP -1 AND FCP-1 SEE DETAILS - SNEE"r F-3.0 111 UISPLA'( 150 36" BOOK DISE LAY FIXTURE ALL WOOD SHALL BE WD -2 5EE DE1%,ILS - SNEF r F-�1.0 151 42" F30OK DISPLAY FIXTURk ALL WOOD SHALL BE WP -2 SEE DETAILS - SNFEr F-�f.0 160 PAPYRUS 5I'INNER FIXT URE ALL WOOD .SNALL BE WD -2 SEE DETAILS - SNEET F-�-.2 161 PA('YRlJS DISPLAY FIXTURE ALL WOOD SHALL FE WP -2 ANP 5l_A"rWALL SL -2 5EE DEIV,ILS - SI-IEE�r f�-�.2 190 BOOKS CUSTOM ALL WOOD SHALL BE WD -2 AND SLAT WALL 5L-2 5LAT4VALL DISPLAY 230 3 POS CASN4VRAP ALL WOOD 5f -TALL DE WD -'1 AND COCZIAN SS -'1 SEE Uk�rAILS - SHEET F-2.�i AND F -2A 300 PIf�IWHEEL GONDOLA ALL WOOD SHALL BE 4VD-1 AND 5LAI�VALL 5L-1 SEE DETAILS - 5f -IFFY F-2.5 l SET IS EXIS-TING TO 6E USED 2 - :"� I�l�-WO�If"��\1=J-,L��TD-SI,A�" - - � -- - '� UNIT IS EXISTING 10 BE USED 350 MOBILE MAGAZINE UNIT EXISTING UNIT Al WATERFALL BARRICADE r0 C'�k USED PROVIDED t3Y l E'NAN r 352 MOBILE CAFIUY UFII'f EXISTING UNI�r AT WATERFALL BARFJCADE T'0 BE USED PCZUVIUEU �Y �rENANT 355 MOBILE NEWS UNIT EXISTING UNIT AT E'�ARKICADE TO BE IJSEU PROVIDED BY -TENANT . 2 SET REQUIRED TO BUILD 360 NESTED TABLE' 2 SE"r5 EXI�rING "rU BE USED ALL WOOD SNALL BE WP -1 SEE DETAILS - SHEET F-2.FJ 371 BOOK'!'ABL.E ALL WOOD SNALL BE WP -2 SEE DETAILS - 51-I�F'r F-�.l 72X3U 375 FRONT AND CENTER ALL WOOD SHALL BE WD -2 TYP. UNIT BOOK D15PLA'( UVU GONDOLA ALI_ WOOD 5{ -TALL BE WD -2 DESIGN HARDWARE -CASHWRAP N0. MFG. QTY. CAT. N0. DESCRIPTION CBM INDUS'iRIES 1 76a RHOMBUS FURNITURE FIXED CASTOR FETHERED II8II.71 7."L831 HAFELE 1 51.00.31 1 ME'T'AL FLUSH HANDLES -STEEL MATTE BLACK IIOU.4L"3.3531 244.20.120 TWIN BALL CATCH 422.88.946 PRECISION BALL BEARING SLIDES -FULL EXTENSION TYPE 1 H -SERIES HINGE HAOE(t COMPANIES 780-224HD RUTON CONCEALED LEAF HINGE WITH BALL CATCH 800.L55.3590 S'�YLMARI< 110008 TRACK HEADER 800.3L8.2�}95 0'LO FINISH COLOR 1101 78 SECURITY BUTTOM'fRACI< 020 FINISH COLOR PHIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NU'I TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. ;. COPYRIGHT 2008 NO. DATE REVISION I 2-22-09 TENANT REVISIONS Hudson News -Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A _INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFOR® INTERNATIONAL AIRPORT SANFORD, FLORIDA F�GFI SII TIL W =1'_O„ G I-0 ------ �-.-/-SCJ---- (2) 1/6" Tl lICK KENIOVA DLE LEXAN FANEL5 - REAR i'ANEL TO 13E DLACK LEXAN, FKONT FANEL TO 13E CLEAK )E - FURNI5I IED VIDE O I 6/4" 21/2" 5/4" 5 D ETA 3" =1'-O„ 21/2" 3'-61/2"CY 100 21/2" 'Y' (cU I U3 IL 3 m ALAN 11/2„ =1,_®„ THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 JL1 5CKEWED 10 FIRE -KATE) FL`(WOOD WITH CONCEALED FLAT HEAD 5CREW5 DAKREL DOLT - FROVIPE HOLE IN DA -5E TO ACCEFT DOLT �Wm LDOLT5TOF& M FIXTIJKE'06 5/4" x 5/4" x'1/8'I vIUM ANGLE "5T'(LMAKf TRIM MAKEK HALF-KOUNP #110200 & 13A5E #41044.3 WITH 5ArlN ALUMINIUM FIN15H #020. FKOVIPE MITERED ANP FKE- KADIU5E1) CORNER5 A5 NECE55ARY FIKE-KArED DL.00KING (- I I I I I l FLJ2LJ i I I I I I I I I I I I I I I I I/ I I I I I I I I I I I I I I I � I I I I I I I I I I FL -1 FIKE-KATE) DLOCKING (TYI') 2 SECTION 11/211 = 11^0 11 NO. DATE REVISION I 2-22-09 TENANT REVISIONS LU G I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I I �r I I I I I I I I I I I I I I I I I I I I I I � I I I I 21/2" 51/=` I I' I I I I I I r �I� I I I I I I 11/2" WD1 WD1 SURFACE MOUNTED DIJFLEX KECEF-rACLE ON EXI5TING WALL. -SEE EI-EVAHON5 FOF: LOCArI ON (2)'1/6" THICK REMOVADLE LEXAN 1;'ANEL5 - REAR r'ANEL TO DE DLACK LEXAN, FRONT 1'ANEL. TO DE CLERK DAKKEL [SOLI'- FROVIDE HOLE IN VALANCE TO ACCEFF DOLr FKOFILE OF LIGHT FIXT IJKE'06' MOUNTED VERTICALLY IN AN - 5EE'LIGHTING SCHEDULE' 5L1 5CREVVED TO FIRE -RATED FLYWOOD WITH CONCEALED FLAT- IIEAP SCREW5 DARKE L DOD'- PROVIDE HOLE IN DA5E TO ACCEPT - DOLT Mr "5r(LMAKK" TRIM MAKER HALF -ROUND 1/110200 & DA5E #41O PIS 5 VVITH SATIN ALUMINUM FIN15H ##020. FROVIDE MITERED AND F'KE- RAPIU5ED CORNEK5 A5 NECE55ARY 1 ELEVATION 11/2" = f-0" Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA I I ! DRAWN DALE 12 -1 -Oa CHECKED JOB NUMBER _ os1�1- SLATWALL DISPLAY j ME: 1 I 11 /2" FIRE -RATED DI-OCKING C PL'1 FIRE-KATED BLOCKING (TYP) l'-7'1/4" WD'I 'I'-0" Affilk SECTION 11/2" -1'-0° AG P'1 WD1 LOCAL INTEKE5T'GKAPHIC DY ANICOM 51GN5- MILLVVOF:K CONTRACTOR TO I'KOVIDE WHITE PLAM, A5 13AGKGKOUND FOR MURAL P L'I 1 '1/2'' THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. <: COPYRIGHT 2008 PROFILE OF COOLER FUTUKE GDM 4! 291/2" X 51" 110 2 PLAN SECTION NO. DATE I REVISION 11/2" = 1'-011 Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL. AIRPORT SANFORD, FLORIDA • I I �— DAKKEL DOLT - PROVIDE HOLE IN VALANCE TO ACCEPT i I I I I I I I I I I I I I I I I hOL-F I I � I I NOTE: KOUT COKE) & PLUG FOK LIGHT I I FIXTUKE5'01','02','03', AND'06 TO KECEPTAG'LE -CONCEAL - VVD1 IN MILLWORK I I I I I I I I I I I I I I I I NOTE: THIS IS TO PE A REMOVABLE DISPLAY SECTION GUILT WITHIN A I GDM 45 ENCLOSURE FOR A I I I I I FUTURE COOLER I I I I I I I I I I I I I I I I I I I I I I I nl PROFILE OF LIGHT FIXTURE'06 MOUNTED I I VERTICALLY IN FIN I � - 5EE'LIGf-MING I I SCHEDULE' I I I I I I 2 I I I I I I I I 5L1 SCKEWED TO FIKE-KATED PLYWOOD —' - WITH CONGEALED FLAT - HEAP 5CKEW5 I I I I I I I I I I I I I I I I I I I I I I DARREL DOLT - PROVIDE — ' I I HOLE IN DA5E TO ACCEPT 1/2" 131/4" DOLT MT'I I 1 I I -- '51YLMAKK"'TRI1vI MAKER HALF -ROUND #110200 & BA5E #410443 WITH SATIN ALUMINUM FIN15H #020, PKOVIDE miTERED AND PKE- �, RADIUSED CORNEK5 A5 NECE55AKY - L .em P L'I 1 '1/2'' THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. <: COPYRIGHT 2008 PROFILE OF COOLER FUTUKE GDM 4! 291/2" X 51" 110 2 PLAN SECTION NO. DATE I REVISION 11/2" = 1'-011 Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL. AIRPORT SANFORD, FLORIDA • 3 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR. DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 H01_E5 IN SIDE FANEL5 TO ACGEFT SHELF FIN5 (TYF) ADJU51-A[3LE 5HELF ON 511ELF FIN5 DARREL DOLT - FKOVIDE HOLE IN 13A5E TO ACGEFT E3OL"I' ("iYF) NO. DATE REVISION 11/2" = p-0" FIRE -RATED Ivi\4 DLOCKING (l -(I') SIJRFAGE MOUNTED DUFLEX RECEFTAGLE ON EX15T ING TVVALL -5EE ELEVATIONS FOR 1-- I LOCATION 2) '1/a" THICK REMOVA13LE EXAN FAHEL5 - REAR FANEL '0 DE BLACK I_EXAN, FRONT 'AHEL TO 13E CLEAR SARREL 13OLT- FROVIDE iOLE IN VALANCE TO ACGEFT 50 L.T 'ROFILE OF LIGHT =1XTIJRE '01' - 5EE ;EILING FI -AH (TYI') " THICK ADJU5TA[3LE 5HE1_F VITH HARDWOOD EDGE5 ON SHELF FIN5 W/ 5AT IN ,IICKEL FIN1511 ('h(F) NOTE: ROUT CORD & PLUG FOR LIGHT FIXT UKE5'01','O2','05', AND'06' 0 0 1-0 RECEPTACLE -CONGEAL IN MILLVVORK CS)o o ' 71 2 SECTION 11/2" ^ V-0" Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA -IOLE5 2" O.C. VERTICALLY 0 ACCEF-r SHELF 12IN5 5TAIH IN51UE OF HOLES -0 MATCH ADJACENT 'AREA 5L1 5CREWEU TO =1KE RA"F'ED PLYVVOOD -` Vrm CONCEALED FLAr- -IEAP 5CREW5 2ROFI1-E OF LIGHT =IXTURE'06MOUNTED /ERTICALLY IN FIN • 5EE'LIGHT1NG SCHEDULE' 3ARREL DOLT - FKOVIDE -]OLE IN DA5E TO ACCEPT 3OLT 5TYL.MARK" TRIM MAKER -IALF-ROUND #110200 & 3A5E #4104IZ WITH 5Arw ALUMINUM FIN15H #020. 'ROVIUE MITERED AND FRE- �AUIU5ED CORNERS A5 \1ECE55AKY 11/211 ^ 11-011 i 34"'HIGH H.C. TRANSACTION COUNTERTOP PLAN 1/2" =1'�O° 1 U"W X 22" H FIRE EXTINGUISHER NICHE WITH SIGN ABOVE SS1 FINISH .n AXONOMETERIC- 3 POS, CASHWRAP ELEVATION 1/2" =1'-0., 7 ELEVATION 1/2"=1-0' WD1 FL1 WD1 rAT2 4 ELEVATION 1/2" =1-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 8 ELEVATION 1/2" =1'-O" NO. DATE REVISION 2-22-09 TENANT REVISIONS ELEVATION 1/2;, =1? 0" r6 F-2.4 6 ELEVATION 1/2 =1'-0" J�-pu —tiT I J I I I 1 -I � _ r _ I W1 1; - 1W[11U\ 9 ELEVATION 1/2" = 11-0" PL1 230 3 POSITION CASHWRAP DRA ATE Hudson N ® Hudson Booksellers CHECKED JOB NUMBER Papyrus I 0b14- RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN 3 POS CASHWRAP TERMINAL A -INTERNATIONAL DEPARTURES UPPER LEVEL ORLANDO SANFORD FEW, INTERNATIONAL AIRPORT EV SANFORD, FLORIDA-�, ELEVATION 1/2;, =1? 0" r6 F-2.4 6 ELEVATION 1/2 =1'-0" J�-pu —tiT I J I I I 1 -I � _ r _ I W1 1; - 1W[11U\ 9 ELEVATION 1/2" = 11-0" PL1 230 3 POSITION CASHWRAP DRA ATE Hudson N ® Hudson Booksellers CHECKED JOB NUMBER Papyrus I 0b14- RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN 3 POS CASHWRAP TERMINAL A -INTERNATIONAL DEPARTURES UPPER LEVEL ORLANDO SANFORD FEW, INTERNATIONAL AIRPORT EV SANFORD, FLORIDA-�, � _ r _ I W1 1; - 1W[11U\ 9 ELEVATION 1/2" = 11-0" PL1 230 3 POSITION CASHWRAP DRA ATE Hudson N ® Hudson Booksellers CHECKED JOB NUMBER Papyrus I 0b14- RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN 3 POS CASHWRAP TERMINAL A -INTERNATIONAL DEPARTURES UPPER LEVEL ORLANDO SANFORD FEW, INTERNATIONAL AIRPORT EV SANFORD, FLORIDA-�, 9 ELEVATION 1/2" = 11-0" PL1 230 3 POSITION CASHWRAP DRA ATE Hudson N ® Hudson Booksellers CHECKED JOB NUMBER Papyrus I 0b14- RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN 3 POS CASHWRAP TERMINAL A -INTERNATIONAL DEPARTURES UPPER LEVEL ORLANDO SANFORD FEW, INTERNATIONAL AIRPORT EV SANFORD, FLORIDA-�, 2" BLACK F'LAST IC GROMMETTO 13 GL:I PLACED IN FIELD AND COORDINATED WITH TNA J �:I E N ra E_ JI( MEN - T r �o VAfI E5 Q\1 551 � ----- � ----- ^ ' I VAEIES 1/4" CLEAR LEXAN II ANGLED DIVIDERS f WITH F'OLI5FIED AND EASEDEDGE5 GC TO COORDINATE ALL POWER AND DATA REOIJIREMENT _ Wrrf1 TENANT KEK o ILI SECTION 11/2" = 11 '0" f'L"1 'rEKKY HINGE HO8-99E60 2'-8 3/4" 2" SS"I f� 114 "HEFELE" KECE55ED FULL 1/2' - - _ 1/2" TYPICAL N .... CU ---- - - - - - -- -- Lq - - - - - - - - - - I � N f'L:I r'LI F'L1 0 �r SECTION 11/2" =1',0" �rD1 C', ACKET I Q 4vD"1 EVERY 4.2 551 1/4" CLEAR - -. - �� LEXAN ANGLED DIVIDERS WITH f'OI-ISHEDAND EA5ED EDGES — r. �.._ _ co WDI\ ....-._.,..:.......:............................:.::;. SHELF ON Cn �r3 iru„� „ 2:-2 2 7- 2 SECTION 11/211 = 11,011 3.. 3'-211 511 b�� 5TYLMARK -rKACK HEADEF; #110008,FINISH #020 1/4" FR 5IJf3sTKATE SLIDING DOOR 5rfLMARK TRACK HEADER #110006,1`11\115H #020 T PLAN DETAIL 11/2" = V-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. :? COPYRIGHT 2008 NO. DATE REVISION C Lf , ., SECTION 11/2" = V-19" ki PLAN SECTION 11/2" = V-0" �n 4 DETAIL 3"=l, -O,, I PLAN SECTION 11/2" =1'-O" Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA GLI TAPERED SHROUD OVER 2" DIA. 5F'RING LOADED GASTER - FINISH GKAY,MODEL IXA f3Y Cf3M INDUSTRIES MOIJNrED ON ANGLED WOOD F31-OGK -r0 ALLOW EASE ON ROLLING IN ARC- FINISH GKAY,MODEL 176A 13Y CDM INDUS TRIES 2 60''rWIN DALL CATCH AS MANE DY HAFELE MODEL #244-.20,120 1/2" 5 DETAIL 3„ =1,�0» - -- /ALUM."ANGLE ALIGN WITH SS TOr SEC`s ION 11/2" =1,-L I SECTION 11/2" =1,.0„ DRAWN DATE 12-1-06 CHECKED JOB NUMBER D&14 4 POS CASHWRAP e- 12 ELEVATION 11/2" 1'-0° 0 530 rnrn BALL BEAKING 5WIVE1_ KING BY RICHELIEU _. #"3010 (200 kg LOAD KA -TING) BELOW bIE55E CUT PAf:I'S (5) 5TACKED TO FOKM DA5E (5EE 5EC ION TI -115 5F1EET) TEFLOrI'5UPER6)IDE5' 51-IEPAKD #9465 38rnrn BASE "rl-IKEADED INTO METAL IN5EKT, -r`(P. 0 DETAIL 3I1 .'. 1 1-011 1 ELEVATION 11/2" 01'-0° 11-Cjll 7 TOP PLAN 11/2° 1'-0" l........ ... OrYI l'I: met _Irl r in a Hinds r com P 0 i1�iIa7L' WD1 -- 16GA.Z PLATE W 5ATIN Al POWDER F11\I15H 'r MATC 1-1( 10 SECTION 11/2" ;110" 0330 rnrn DAL DEARING 5WIVEL. KING DY RICHELIEU #3010 (200 k(j LOAD RAT] NG) DE LOW 16 GA. ZINC PLATE vv/ 5ArIN ALUM. POWD F KCOAT FIN15H TO IvIATC H MT2 WD1 51'1 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2 G 008 ll_�u 3 3/4" 11"� 1111/2"" 11"1 515/41, 6 PLAN SECTION 11/2° = V-0" NO. DATE REVISION ___ 11/2" ^ 1'-0" 0330 rnrn BALL — — — — — ------_. - --- ---- 11/2" 1'. -'Il 1/2" J DEARING 5WIVEL � -- -- -- - KING D`( KICHELIEU #3010 (200 kg �— t✓rr1 ABOVE LOAD RA"rIN(:-;) NOTE: GRAIN TO KUH AL1 — f3ELU4V I `� x\ , �� I 13IE55E CUT PAK'r5 w-rE: (5) 5TACKED TO FOKM DA5E 5115-rIUN ALL FLYWOOD AND I 1 LAMINATE'r0 DE (5EE 1 I TI -115 5HEET) I WD1 I I O O 6� \ \�-7— /ACCE55 I I t:EG1'D TO SECURE >(\/ ..........� ......:.......... f KING Nil. 1 Q J, fN 6 PLAN SECTION 11/2° = V-0" NO. DATE REVISION ___ 11/2" ^ 1'-0" 0330 rnrn BALL — — — — — ------_. - --- ---- 11/2" 1'. -'Il 1/2" J DEARING 5WIVEL � -- -- -- - KING D`( KICHELIEU #3010 (200 kg �— t✓rr1 ABOVE LOAD RA"rIN(:-;) NOTE: GRAIN TO KUH AL1 — f3ELU4V I `� x\ , �� I 13IE55E CUT PAK'r5 w-rE: (5) 5TACKED TO FOKM DA5E 5115-rIUN ALL FLYWOOD AND I 1 LAMINATE'r0 DE (5EE 1 I TI -115 5HEET) O O I I O O \ \�-7— /ACCE55 HOLE A5 I t:EG1'D TO SECURE >(\/ KING 1 Q J, 2 F-2,5 —r = m I I - U5E PREFORMED RADIU5 -- _ COKHERS (J 51-lAf'E) �- CV �— - f L"1 W/ KADIU5ED CORNER5 .2 ELEVATION WD1 NI'I'"I U5,E PREFORMED C5L"I PL. f3DIUS COF;NEI?5 (J I 5FIAPE) -ems- -- - KICK DELOW FLAT TOF ADOVE VOID - w[) - - I r I [} 11 1/2" j 2' I 11/2" 1" 2'-11/2" 1 PLAN v =1'-0" Hudson News -Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA 5L' DETA HALF SCALE I L " BULLNOSE EDGE LOW [7Ll Jl.l�l I`IU A5 REOT) SECTION PINWHEEL GONDOLA NTS ;gHto i9 DRAWN DATE 12-1-0& CHECKED JOB NUMBER Od"14 PINWHEEL GONDOLA KEY / MAGNET UNIT F-2.5 R E'%V" 113" 10 N 1 1/2" -rKIM FLAT 11/4" - --- ---- 11/2" 1'. -'Il 1/2" J PROFILE:, f0N PIEGES ONLY. W1)1 'I 1/2" HAPTWOOD E5 LLN05E, 511)E PIECE5 0 N LY. -- -- -- - NOTE: GRAIN TO KUH AL1 — VEKTICAL w-rE: ALL FLYWOOD AND LAMINATE'r0 DE FIRE K/ATED —r = m I I - U5E PREFORMED RADIU5 -- _ COKHERS (J 51-lAf'E) �- CV �— - f L"1 W/ KADIU5ED CORNER5 .2 ELEVATION WD1 NI'I'"I U5,E PREFORMED C5L"I PL. f3DIUS COF;NEI?5 (J I 5FIAPE) -ems- -- - KICK DELOW FLAT TOF ADOVE VOID - w[) - - I r I [} 11 1/2" j 2' I 11/2" 1" 2'-11/2" 1 PLAN v =1'-0" Hudson News -Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA 5L' DETA HALF SCALE I L " BULLNOSE EDGE LOW [7Ll Jl.l�l I`IU A5 REOT) SECTION PINWHEEL GONDOLA NTS ;gHto i9 DRAWN DATE 12-1-0& CHECKED JOB NUMBER Od"14 PINWHEEL GONDOLA KEY / MAGNET UNIT F-2.5 R E'%V" 113" 10 N LINE OF LAKGE IADLE DELOW PLAN 11/2" ='I' -O'' 91/21 PLAN= LARGE TABLE (1 REQ'D) 11/2" = .11.0 PLAN '1 1/211 21_.1.1 loor e� I DOVETAIL JOIN -r5 r ---r---------------------------------- ----------- I I I I I------------------------------------------------J f — J Lr— { I I I I I I I I 1U I I I I - I I I I I I I I I I I I I I yvIA I - I I I I I I I I I I I I I I I I I I I I I 2" VVIDE HARDWOOD — + 1-------------------------------------------i----1 I ------------------------------------------- 8 11 - 7 PLAN - SMALL TABLE (2 REQ'D) 11/2" = 1'-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION TYK 4ELEVATION 11/2" ='I' -O" ELEVATION 11/2" =1'-011 02'-01 1Q SECTION 11/2" = .1'_011 5 ELEVATION '11/2" - "11_011 /)I� J1_211 2' CV or 1/4"A" GROMMET, T`(F.. o — LINE OF 211 SHELF A13OVE Q WGl 0 0 1 irk (W[)]) o HARDWOOD EDGE o .1011 PLAN= LARGE TABLE (1 REQ'D) 11/2" = .11.0 PLAN '1 1/211 21_.1.1 loor e� I DOVETAIL JOIN -r5 r ---r---------------------------------- ----------- I I I I I------------------------------------------------J f — J Lr— { I I I I I I I I 1U I I I I - I I I I I I I I I I I I I I yvIA I - I I I I I I I I I I I I I I I I I I I I I 2" VVIDE HARDWOOD — + 1-------------------------------------------i----1 I ------------------------------------------- 8 11 - 7 PLAN - SMALL TABLE (2 REQ'D) 11/2" = 1'-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION TYK 4ELEVATION 11/2" ='I' -O" ELEVATION 11/2" =1'-011 02'-01 1Q SECTION 11/2" = .1'_011 5 ELEVATION '11/2" - "11_011 ELEVATION 11/2" =1'-0" 2'-0" OL 1' -F" - - - - - - - - - - - - - - - 21-011 o_ ------------- SECTION ----------- SECTION 1 1/21' = .11.011 �II Hudson News Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA NOTE: INSTALL TABLE ON CASTER - VERIFY WITH TENANT REP. s SECTION 11/2' =1 1-01' 1'-9" LARGE TADLE 3/4" PLYWOOD, TYE 170TH 51DE5 12 SECTION SMALL TABLE (tiVDI) MOR-r15E / -rENON JOINT5 �1 MORTISE AND TENON DETAIL SII AXONOMETRIC W[)1) NAKDWDOD DRAWN DATE 12-1-08 CHECKED JOB NUMBER 0814 1 NESTED TABLES F-2.6- EVIb&IO I � 4VU1 11 011 211 ELEVATION 11/2" =1'-0" 2'-0" OL 1' -F" - - - - - - - - - - - - - - - 21-011 o_ ------------- SECTION ----------- SECTION 1 1/21' = .11.011 �II Hudson News Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA NOTE: INSTALL TABLE ON CASTER - VERIFY WITH TENANT REP. s SECTION 11/2' =1 1-01' 1'-9" LARGE TADLE 3/4" PLYWOOD, TYE 170TH 51DE5 12 SECTION SMALL TABLE (tiVDI) MOR-r15E / -rENON JOINT5 �1 MORTISE AND TENON DETAIL SII AXONOMETRIC W[)1) NAKDWDOD DRAWN DATE 12-1-08 CHECKED JOB NUMBER 0814 1 NESTED TABLES F-2.6- EVIb&IO F-3.0 2 F-3.0 ACFI JII ACP1 / 1 FIRE -RATED I 5URFACE MOUNTED UUf'LEX DLOCKING (-r'rf') PECEf TACLE ON EXISTING _ � �� WALL. -SEE EI-kVA'r10N5 FOR r---, �, — <r , •—.—.—._ I I LOCATION J -F3 I I ' ,,\\ �,;\ CV ----•— -- — � � I _ � ._.moi i 6TI I P1_2 FANEL FOR � i I LOCAL IN"I-Ff'. -5T M U RAL L - - - J t --- ' — 6/4" 2 1/2" 3/4" _ I (GRAf'HIC5 PROVIUEI) ra ANO IN51'ALLED D CN Lq - I AN COM 51GN5) All tiVD1 I PL2 PANEL FOR n 6/4" 4" LOCAL INTERE5.1- MURAL I _ (GRAPHIC5 FRUVIUEU I I ASID I,NSfALLED DY DARREL BOLT - PROVIDE ANICUM SIGNS) �� HOLE IN VALANCE TO ACCEPT "'; L; LJ LJ JDOLT FROFI .E OF LIGf-rr FIXrIJKE'03' - 5EE 1'-71/4" A" 1/2" i CEILING PLAN (fYF) I I I I I I I I I I _ WU1 NOTE: to RoUT GURU & PLUG FOR LIGHT FIX -i U RE5 'O1', 'O2', 'O5', AND 'Ord' 'r0 RECEPTACLE -CONCEAL �Y c" i W1j.l IN MILLWORK Q E x 17ARREL DOLTS, TOF & 'vi� — DO rTOM1 WPI r I ., 7'-01/2" .�-, ,III \ —--------------------- n I I I I I I LIGHT FIXTURE IOU LIGHT I Imo.., FIXTURE CA AGORY 5IGNAGE - FURNI5HED T I I I I I I DY ANICOM 51GN5• tc) 4VD1 - J LU I I DAKREL DOLT- i'KOVIDE HOLE IN VAI_ANCF I U WVI CONT; 5/4" x 5/4" x 1/8" CU (D 4 'I/2" I 'I/'L" 3 �T" ACCEPT DOLr AL.IUMINUM APIGLF 4 ADJUSIAS�� GL2 SHELVES ON "12"LUNG T I I DF:ACKF'15 I12602-1 B`( "CAPfrOL°, POLISHED I I I I I I CHROME FINISH. G.C.'ro PROVIDE CLIP #2077-1 AND/OR 112077-2, (2) FER BRACKET I I I I I ANE) 51-ICTION CLJF #115 A5 NEEUEU. U &7L 2D FKOFILE OF LIGHT FIXTURE'O✓u-" MOUNTED VERTICALLY IN FIN DETAIL D ET�i L GAFI"1OL' [� LINE GU CCAE_FD WALL '6, 9 510N T - 5EE I_IGHTI�IG I I VF-F,l-ICAL FANEL STANDAf,U /12 2.a �, 9G-3 SCHEDULE' rIIGH, GlJ-r TO MATCH DIMEN51OH5 ON DWG., 311 11�011 311 = 11�011 DKIGH`f'ZINC OK DLAGK ENAMEL FIN15H. I I I I I I I i i I I FCP1 FA[3RIC �I OVER KOKLIT E FAHE1_5 I I I I I I I I I I I I 21/2" 4'-U" C� 140 21/2" r' WD1 2'-0" V 141 I I u G� .I " .I II 11-011 -0 1-O 611 - I I BARREL DOLT- PROVIDE lF HOLE IN DASE TO ACCEPT - rl /2 u ; II'll BOLT \ I / I 1 _ 1 1/2:' C I \ I I I N l F-3,0 I WD1 FC.'P1 �f;Ll 5TYLMARK" TRIM MAKER \ I - FABRIC HALF -ROUND #110200 & \ OI OVER KOrLITE PANED DA5E #41-10'43 WITH 5A-1 IN r � ALUMINUM FIN51-1 11020. � r, *II r, I 0 PROVIDE MITERED AND PRE- RADIU5E [) COKNER5 A5. BARREL DOLT - FRoVIDE — NECE55AR'( J HOLE IN DA5E -rO AGGEFT —��, -- DOLT WDI LQ — -- <r FIRE -RATED PLh LQ BLOCKING (T(P) 1 1/2" 5 Nrrl � "5TrLMAKK` TRIM MAKER F 3.0 HALF -ROUND #110200 & DA5E #410443 WITH SATIN ALUMINUM FIN15H #020. FROVIDE MITERED AND FRE - PLANRADIUSFD GORi1ER5 A5 2 NECE55AR'( SECTION ELEVATION. 11/2" =1'-0" 11/2 11-0" 11/2" = 1'-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. .;: COPYRIGHT 2008 NO. DATE REVISION Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA PROF GFIOV ADC4 CON HINC FUT URA ON LL OUT51PE OKNEKS, rY1') 3 PLAN DETAIL 11/2" ^ 1'-0" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 ,LL CATCH DY MODEL ).'120 2 3/S" NOTE, ENSURE THERE VENTALATION 7 FOR EP CLOSET 2 SECTION 11/2" = 11 "0" - NO. DATE REVISION 1 2-22-09 TENANT REVISIONS TO )OP 1-1 -1EAP 1 ELEVATIOIN 11/2" ®1'-0" Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12-1-08 CHECKED JOB NUMBER a ELECTRIC PANEL ENCLOSURE 00 g� F®3. 1 / / / / / / ALIG�(5LATWALL w EQ / 2'-F�" ECS / / / / / FA55AGE 5ET - \ DKU5HEPALUM. LEVEK HANDLE -- \ 1 ELEVATIOIN 11/2" ®1'-0" Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12-1-08 CHECKED JOB NUMBER a ELECTRIC PANEL ENCLOSURE 00 g� F®3. 1 THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION I 2-22-09 TENANT REVISIONS RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL_ DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA PLAN 11/2" _ .1,-0" "Aft LTJ SECTION 11/2" =]'-O" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 A)2 OWELED TOP AND '0110M, 1/4" x1" %KOMMET, 5LEEVE TYP, D2 1)2 ADJ. SHELF D2 552 P50-250 GA5TEK5 NO. DATE REVISION 2 SIDE ELEVATION 11/2" =1'-0" I WD2 5L2 WD2 552 ZI'I-0II 3 _FRONT ELEVATION 11/2" �=.I.O NTS Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12 -'I -U8 CHECKED JOB NUMBER Od14 BOOK TABLE F-4.1 DOWELED TOP AND BOTTOM, 1/4"x1" GKOMMET, TYP, �� II �9 N O T VVD2 WD2 - L" �o PLAN 11/2" _ .1,-0" "Aft LTJ SECTION 11/2" =]'-O" THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 A)2 OWELED TOP AND '0110M, 1/4" x1" %KOMMET, 5LEEVE TYP, D2 1)2 ADJ. SHELF D2 552 P50-250 GA5TEK5 NO. DATE REVISION 2 SIDE ELEVATION 11/2" =1'-0" I WD2 5L2 WD2 552 ZI'I-0II 3 _FRONT ELEVATION 11/2" �=.I.O NTS Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12 -'I -U8 CHECKED JOB NUMBER Od14 BOOK TABLE F-4.1 ACNi �AGt'1- FIRE,-f'.ArEU FIKE-KAI LP DLOCKING (1YN) P1_2 COVEKED PANEL [3`( DLOCKING (T(") f'L2 COVERED f'ANIEL DYMILI_WOKK CONTRACTOR AND 0KAFHIC [3Y ANICOM — MILLWOKK CON'TRACfOK 51GH5 AND GRAPHIC DY ANICOM 5IGH5 -) �C) 2'-51/4° �I- .10/0/r7 F -q -.O F-4.0 If IAKDWOOU PAINTED _ HARDWOOD FAINTED G. �. ♦. Jrl -- GLO55 ( [SLACK f GLUSh'( [.,LACK � �Lq I<<) ELECTRICAL KECErIACLE I — ELECIKICAL KECEPTAC'LE r WD2 WD2 4RE 13ULKHEAD TO DE MODIFIED DAr;KEL r30LT - NKOVIDE DARKEL DOLT - NROVIUE AT AKEA OF PAI-"YKIJ5 HOLE IN VALANCE TO xACCENT PINNEK LOCATION � � HOLE IN VALANCE TO ACCENT 4 1/2 DOLT NL2 � J. 5 '1/2" DOLT i I ° I i I I I I CUSTOM SPINNERS TO BE SUPPLIED BY PAPYRUS THROUGH HUDSON GROUP I I l ( l I I I I I I I I I I r `a I4VU2� I I I I 'fI � 1= � I <r I I 1 I I I I I I 1 ( Z r � NOTE: NOTE: ° ; KOU'f CURD &PLUG FOR LIGHTROUT COKP & PLUG FOR LIGHT _ I FIxTUKES'nI','02','0 ?)', AND'OU' °L FIX'rURE5'0i','02','O6% AND'00' - iTO RECEI'TACLE -CONCEAL ° ° TO KECEI'TACLE -CONCEAL I IN MIL!_WOKK IN MILLWORK I I I I NKOFILE OF LIGH-r ; NKOFILE OF LIGHT ( _ I FIXTURVOU IVIOUNTEP FIXTURE06 MOUNTED VERTICALLY IN FIN VEKTICAI_l_Y IN FIN 5EE'L!G[i TING; ° ° 5EE LIGH TING 5CHEPULE' 5CHEPULE' I I I I I I j 1 1 _ I AL2 5CKEWED TO FIRE -RATED PLYWOOD WITH CONCEALED FLAT- ' I I HEAP 5CREW5 I I I I WD2 �r I I I I I I I _TIT ° I I I I I I I I I I I DARKEL DOLT - PROVIDE - DARREL 130L:r - NROVIPE I " r I1i HOLE IN DASE 1-0 ACCEPT HOLE IN DASE "f0 ACCENT 1 BOLT ) DOLT l I I I I/GTI _._..I 1. _.I - I I I ` I �7 1/2" 13 '1 /"t I' I� �52 5GLIU 5UF' FACE DA5E ��52 Dv SOLID SURFACE DASE I \I I � FIRE -RATED FIRE -RATED �—� �. DLOcKING (T -(f') BLOCKING (TYP) F-4.0 F 4.0 SECTION SECTION THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 2-22-09 TENANT REVISIONS , ----.--- Hudson - 1__o_ Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12-1-05 CHECKED JOB NUMBER 0814 PAPYRUS WALL UNITS M ETALU NA Architecture & Desitin P.C. 1665 hlighway 588 Ellisville, MS 39,137 TEL 601.9 14.6909 FAX 601.763.4886 www.MET/-\LUN, email: metalunaC THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 m NO. DATE REVISION 1 2-22-09 TENANT REVISIONS Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES -UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA DRAWN DATE 12-1-08 CHECKED JOB NUMBER 0814 PAPYRUS DISPLAY TABLE ,VOW F-4.3 LIGHT FIX'j"IrURE SCHEDULE NO, SYMBOL DESCRIPTION MANF / MODEL # LAMP FF r I» 5 Highway X88 ? :• : :• :• Euisviu _ rir) 39437 7 r u 2 X 2 KECE55ED PARADOLIC LOUVER, FLUORESCENT LIGHT 'COOPER-METALUX' (3) 1 -AV T& LAMPS 131 v .... ....:::: .... . ..:::.::.:. FIXTURE, 9 CELL, (3)17W TS LAMPS, 120V 2EF5GAX-317-12OV-E13,5 - email; rne�taluna( mindsprin�.corn G �. r. 2 X 2 KECE55EP PARADOLIC LOUVER, FLUORESCENT LIGHT 'COOPER-METALUX _ (3) 17W r5 LAMPS �1Fnn > 1 FIX-rUE".E, 9 DELL, (5)'17W T& LAMPS, EMERGENCY DATTERY PAC, 2EF5GAX-517-120V-ED(3-EM -ur INDICA"rOR LIGHT, 120V U5E'DODINE' D50 FLUOR. 131 B EMERGENCY 13ALLA5T F1 O 6" LINE VOLTAGE RETROFIT COMPACT- FLUORESCENT 'CONTECH' (2) CF26DTT nl Til �.EGE`>J��ED FIXED DOWNLIGN-f W/ WHITE DAPPLE RL226-R /26-26 wCTP,1826-02 01 LINEAE: FLUORESCENT, (1)14W Tb ARCH. DARTCO' DFL255-14PCW (1) F14T3 FIXTURE W/ INTEGRAL 5ALLA5T AND POWER CORD & PLUG, 120V, (15 5/51) 0� LINEAR FLUORESCENT, (1) 25W -F3 ARCH. FIXTURE W/ INTEGRAL DALLAST AND DARrCO' DFL255-17PCW (1) F1%T8 POWER CORD 6. PLUG,120V (24 5/51) I II 111-- I III � I I ILI 03 LINEAR FLUORESCENT, (1) 25W T5 ARCH. 'DARTCO' DFL255-25PCW 'U5E (1) F25T8 t^- 4�I^-�� / I --t`F ` FIXTURE W/ IN-rEGRAL 5ALLA5T AND 5r/\GGEKED FIXTUKE & EXTRA POWER CORD & PLUG, 120V (36 501) LONG LIFE Lr\MPS Af30VE GALLEKIE SHELF 1 I/ LINEAR FLUORESCENT, (1) 35W T& ARCH. B1 06 B1 FIXTURE W/ INTEGRAL DALLA5T AND DARTCO' DFL255-2525PGW (2) F25T8 BI POWER CORD & PLUG, '120V (751/4"L) X1 ARCHITECTURAL EDGE -LIT EXIT 51GN NOTE; ALL LIGHT FIXTURES SPECIFIED ARE TO BE PURCHASED BY THE G.C. THROUGH THE TENANT'S LIGHTING CONSULTANT - CHARLIE AND COMPANY, CONTACT VIRGIL @ (309) 665-5643 NOTE. LIGHTS MUST BE PREPAID BEFORE DELIVERY METALUNA DATE REVISION 1 i� Arcf litecture & L)eslb n PC,, _ OWNER REVISION FF r I» 5 Highway X88 ? :• : :• :• Euisviu _ rir) 39437 7 r u 06, TEL 60 1.9 1,1,6909 ����N :.....::.:>:::.>: FAX 601.763.4886 av< v .... ....:::: .... . ..:::.::.:. r. www, ME rAL NA r r' �� U a C IItC _tom. _OfYI - email; rne�taluna( mindsprin�.corn G �. r. THIS DRAWING AS AN INSTRUMENT OF � SERVICE IS ANDS HALL REMAIN HE PROPERTY OF ARCHITECT. USE OF THE DRAWING OR ANY REPRODUCTION THEREOF, WITHOUT ouT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION T o O MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BEN TR ED CO S U AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 ELECTRICAL_ SYMBOLS AND LEGEND CONDUIT AND WIRE (IN CONCEALED LOCATIONS WHEN POSSIBLE) - HASH MARKS SHOWN FOR SWITCHING CLARITY ONLY. SIZE CONDUCTORS PER 2005 NEC. "HOME RUN" TO PANEL BOARD - SUBSCRIPT DENOTES PANEL AND CIRCUIT DESIGNATION NOTE TO CONTRACTOR; PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE TO VERIFY FIELD CONDITIONS FOR HIS PARTICULAR TRADE. IF THERE ARE DISCREPANCIES IN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS THEN THE CONTRACTOR SHALL PREPARE A BIDD BASED ON ACTUAL FIELD CONDITIONS AND IMMEDIATLY INFORM THE ARCHITECT IN WRITING OF THE THE DISCREPANCIES. IF JOBSITE IS NOT VISITED PRIOR TO BIDDING THEN THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ABOVE MENTIONED DISCREPANCIES. I_ANULOKV5 EXIU-nNG __-_ -ml --n- A DATE REVISION 1 2-22-09 _ OWNER REVISION OU5F'ENDEU CEILING r u - I lul pu � II -III I II ILII I -ur B 1 Em 131 B nl Til li iiii I I II 111-- I III � I I ILI t^- 4�I^-�� / I --t`F ` 1 I/ L�_iiii I r__n--ILII B1 B1 /� i B1 BI B1 I II IIID / ; 11 II III l u ull ii Lil ii Lijd �ffi ,1 i � i i l L-1,3 I II III III / � _J ii iiii lu i / 1.3 II I II ILII ii Ly__1y�1 131 131 / � % % B1 EM 131 B1 EM L- II (VIA T )Ii �I / I L i % 1 / LAMM ll - I j 1312mJ i B1 131 B1 B1 I F"lrt I u Ili I I I LLL H± L±I 111 11' III I' B1 B1 B1 I 1 B1 I F I R LJlii iii; I,°° I it------ _-; B'1 B1 B1 B1EM FIR ---- r --- Ir' �I-- — mil f I �-�-•� I I I Ell I B1 B1EM 131 131 B1 B1 I FIR !IT I � I II I --Til 131 B1 B1 B1 B1 B1 I I i FIR � LLL LEI HE LLL1_ I I I I BI B1EM 131 BI - B1 BIEM I FIR I , , I III I -II - III II i III i B1 B1 _ B1 B1 _ B1 B1 I ' F1R I _ L i 71 I li I I ;I LLLJ H ffid ±H- I ---- ---------II --II 1iITIIIlIrlI- r 1III --------I -----,IIIrjLII - --•- I -�rII �i�IIII� ,II(III-TTIII -"�I '---- FIR I1 F I ]iI- ---_-- ---------- ItI {'LILt -I ----- --- + - -------J 1I I Ili I III I III I I I II I I it ii l I ------ L'----' ------ L----- ------- -� -7 I`' --------^-----Ji ill I I -o- LIGHTING PLAN 1/4" =1'.�0" NO. DATE REVISION 1 2-22-09 _ OWNER REVISION ADJACENT RESTAURANT -! - R 1R FIR FIR FIR F1R Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN �, I EXI5T LNG 5OFFIT TO KEMAIN EXI5TING 51J5 ENL CEILING, LIGHTING & mFFU5EF,5 -ro REMAIN I I i I � I I I � 1 I I I LINA. OF EX15-rING 51GN SHELF I \ A13OVE TO REMAIN I I I I I I I 1 ----------------------------------------- EXI5TING GYF. be-- [3D.5OFFrr-ro •ro�IKEMAIN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SAN FORD INTERNATIONAL AL AIRP® RT SANFORD FLORIDA ------------------------------- --------- NEW 5 rOKEFRONT 51c�jN I I I I DON PENN, P.E. FLORIDA ENGINEER N0. 0051096 ME ,H S dp635 WESTPOR T PARKWAY SUITE 300 GRAPEVINE, TEXAS 76051 817-410-2858 FAX 817-251-8411 DRAWN DATE JVP CHECKED JOB NUMBER DP L. U all ELECTRICAL_ SYMBOLS AND LEGEND C) JUNCTION BOX - SHALL BE ACCESSIBLE AFTER COMPLETION OF CONSTRUCTION T PHONE OUTLET MOD 01> DATA OUTLET CR 00> CASH REGISTER OUTLET S SINGLE POLE WALL SWITCH - MOUNT 48" ABOVE FLOOR UNLESS REVISION INDICATED OTHERWISE 2-22-09 DISCONNECT SWITCH (NEMA -3R IN WET LOCATIONS) FURNISHED DUPLEX RECEPTACLE MOUNTED 18" ABOVE FLOOR UNLESS NOTED OTHERWISE NO. QUAD RECEPTACLE MOUNTED 18" ABOVE FLOOR UNLESS NOTED OTHERWISE IG/SS � ISOLATED GROUND/SURGE SUPRESSION RECEPTACLE MOUNTED 18- ABOVE FLOOR, UNLESS NOTED OTHERWISE, HUBBELL # G5362 (BLUE) IG/SS = ISOLATED GROUND/SURGE SUPRESSION RECEPTACLE MOUNTED 18" ABOVE CA511 KEGI5'rEK FLOOR, UNLESS NOTED OTHERWISE, (2) HUBBELL # G5362 (BLUE) �C TELEVISION CONNECTION DEVICE CONDUIT AND WIRE (IN CONCEALED LOCATIONS WHEN POSSIBLE) HASH MARKS SHOWN FOR SWITCHING CLARITY ONLY. SIZE CONDUCTORS PER 2002 NEC. "HOME RUN" -f0 PANELBUARD -SUBSCRIPT DENOTES PANEL AND CIRCUIT DESIGNATION T-, "HOME RUN" TO TELEPHONE BACKBOARD - 1 " C WITH PULL CORD TO TEL -BD. TERMINATE ABOVE TEL -BD. FOR USE BY OTHERS. IG/SS ISOLATED GROUND/SURGE SUPRESSION CR CASH REGISTER IG ISOLATED GROUND AFF ABOVE FINISHED FLOOR DATA & COMMUNICATION SPECIFICATIONS: COMMUNICATION: 1. PROVIDE (4) FOUR CAT 6 CABLES, WHICH INCLUDES (1) ONE GRAY CABLE FOR VOICE FROM BLDG. TELEPHONE BACKBOARD TO CASHWRAP. 2. TERMINATE (3) THREE SEPERATE PHONE LINES INTO (3) THREE SEPERATE RJ1 1 .JACK WALL PLATE ON THE LOWER SECTION OF THE CASHWRAP AT THE MAIN REG- ISTER LOCATION. 3. TERMINATE (1) ONE ADDITIONAL PHONE LINE INTO A RA 1 WALL PLATE JACK ON THE LOWER SECTION OF EACH ADDITIONAL CASHWRAP REGISTER LOCATION. 4. PROVIDE A LABLE ON RJ1 1 WALL PLATE INDICATING THE TELEPHONE NUMBER AT EACH LOCATION. 5. CERTIFY CONTINUITY OF EACH PHONE LINE. DATA: 1. RIJN (1) ONE GE PATCH LINE FROM EACH REGISTER BACK TO OWNER SUPPLIED HIJB, LOCATED AT THE LOWER SECTION AT MAIN CASH REGISTER, TERMINATE WITH A MALE RJ45 AT BOTH ENDS. 2. OWNER WILL PROVIDE AND INSTALL ALL CASH REGISTERS, MODEMS AND HUBS. CONTRACTOR TO COORDINATE LOCATIONS WITH OWNER. 3. ALL DATA CABLE TO RUN UNDER THE CASHWRAP IN CONDUIT. TERMINATE CONDUIT ON THE LOWER SHELF AT EACH CASH REGISTER LOCATION. PROVIDE ENOUGH SLACK CABLE TO REACH TO THE TOP OF THE CASHWRAP AND PLUG INTO EACH CASH REG- ISTER. PROVIDE (1) FOOT OF SLACI< CABLE AT THE MODEM HUB END OF EACH CABLE. 4. PROVIDE LABEL FOR EACH CABLE AT THE MODEM HUB END. 5. CERTIFY CONTINUITY OF EACH DATA CABLE. 1. PROVIDE (1) ONE 120 VOLT ISOLATED GROUND QUAD RECEPT ON A DEDICATED CIRCUIT ON THE LOWER SECTION OF THE CASHWRAP AT THE MAIN CASH REGISTER LOCATION. 2. PROVIDE (1) ONE 120 VOLT ISOLATED GROUND DUPLEX RECEPT ON A DEDICATED CIRCUIT ON THE LOWER SECTION OF THE CASHWRAP AT EACH ADDITIONAL CASH REG- ISTER LOCATION(S). 3. CERTIFY CONTINUITY OF EACH OUTLET. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 +104" (TYP) NOTE_ TO CONTRACTOR: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE TO VERIFY FIELD CONDITIONS FOR HIS PARTICULAR TRADE. IF THERE ARE DISCREPANCIES IN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS THEN THE CONTRACTOR SHALL PREPARE A BIDD BASED ON ACTUAL FIELD CONDITIONS AND IMMEDIATLY INFORM THE ARCHITECT IN WRITING OF THE THE DISCREPANCIES. IF JOBSITE IS NOT VISITED PRIOR TO BIDDING THEN THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ABOVE MENTIONED DISCREPANCIES. POINT AND PROVIDE A 1 " CONDUIT FROM THAT CONNECTION TO THE SPACE WITH PULLCORD FOR FUTURE USE. NO. DATE REVISION 1 2-22-09 _ OWNER REVISION FURNISHED `�(POWER PLAN 1/4 1 = 11-011 A - - EQUIPMENT SCHEDULE ELECTRICAL. FURNISHED INSTALLED NO. ITEM MOUEUMANUFACTURER SIZE _- BY BY CA511 KEGI5'rEK VEKIFY VERIFY VEKIFY TEI IANT G.C. Of EN FACE '50UTHEKN 5TOKE FIXTUKE INCA 501/21V x 29 5/8"D 120/240 4 WIRE WITH TENANT G.C. KEFF:IGEKA"IED CASE MDc-%oHN5c x 78 5/(5"Fl NEUTF:AL NEMA:L"I�1-201', 16 -OA 42" FLAT 5CREEN 015PLA( VERIFY VEKIFY VERIFY fENAN f G.C. DIGITAL PKOCE550K VEKIFY VERIFY VEKIFY TENANT G.C. Hudson Hudson BookseRers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE_ IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA dpDON PENN, P.E. FLORIDA ENGINEER NO. 0051096 (MECH) 635 WESTPORT PARKWAY, SUI1E 300 GRAPEVINE, TEXAS 76051 817-110-2858 FAX 817-251-8411 If DRAWN DATE JVP CHECKED JOB NUMBER DP 0814 FIRE ALARM SPECIFICATIONS 1. FURNISH ALL REQUIRED LABOR, MATERIALS, EQUIPMENT AND CONTRACTORS SERVICES NECESSARY FOR THE COMPLETE INSTALLATION OF FIRE ALARM ITEMS AS INDICATED ON THE DRAWINGS, INCLUDING BUT NOT LIMITED TO THE FOLLOWING: A. STROBES. B. WIRING DEVICES. C. PA SPEAKERS. 2. DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND WORK. CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES, REGULATIONS BUILDING STANDARDS AND THE BEST PRACTICE OF THE TRADE FOR THE INSTALLATION OF FIRE ALARM WORK. 3. THE FIRE ALARM WORK SHALL COMPLY WITH THE LATEST F.B.C. FOR THE STATE OF FLORIDA AND LATEST AMENDMENTS, MDAD DESIGN GUIDELINES MANUAL(DGM) AND LIFE SAFETY MASTER PLAN, NATIONAL ELECTRICAL CODE OF THE NEPA-NEC, NFPA 72A, 72E, 101, 70, ARTICLE 760, '15, 16, 21., STANDARD OF THE NATIONAL BOARD OF UNDERWRITERS, OSHA, THE BUILDING MANAGEMENT STANDARDS, MDAD AND ALL AUTHORITIES HAVING JURISDICTION. THE CONTRACTOR SHALL SECURE ALL CERTIFICATES OF REQUIRED ORDINANCES, AND DELIVER THEM 'TO THE OWNER'S REPRESENTATIVE. 4. THE CONTRACTOR SHALL HAVE HAD EXPERIENCE ON AT LEAST (2) PROJECTS INVOLVING QUANTITIES AND COMPLEXITIES AT LEAST EQUAL -1-0 THOSE REQUIRED UNDER THIS PROJECT. THE CONTRACTOR SHALL VISIT AND EXAMINE CAREFULLY THE AREAS AFFECTED BY THIS WORK TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND WITH DIFFICULTIES THAT WILL ATTEND THE EXECUTION OF THIS WORK. THE CONTRACTOR SHALL PERFORM THIS PRIOR TO SUBMITTING HIS PROPOSAL. THIS WILL BE CONSTRUED AS EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE, AND LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT, OR MATERIALS REQUIRED BECAUSE OF DIFFI (�ULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN HAD SUCH AN EXAMINATION BEEN MADE. 5. UPON REVIEW OF FIRE ALARM DRAWINGS PRIOR TO SUBMITTING HIS PROPOSAL, THE FIRE ALARM CONTRACTOR SHALL INFORM THE ARCHITECT AND/OR ENGINEER OF ANY DISCREPANCIES OR REQUEST CLARIFICATION, IF NECESSARY, CONCERNING THE INTENT OF THE PLANS AND SPECIFICATIONS TO PROVIDE A COMPLETE FIRE ALARM INSTALLATION. LATER CLAIMS WILL NOT BE RECOGNIZED FOR EXTRA LABOR, EQUIPMENT OR MATERIALS SHOULD SUCH PROCEDURE NOT BE FOLLOWED. 6. THE C'ONTRAC'TOR SHALL COORDINATE HIS WORK WITH OTHER CONTRACTORS WHOSE WORK MIGHT AFFECT THIS IN CONTRACTORS SHALL ARRANGE ALL PARTS OF 'THIS WORK AND EQUIPMENT IN PROPER RELATION TO THE WORK AND EQUIPMENT OF OTHERS AND WITH BUILDING CONSTRUCTION AND ARCHITECTURAL FINISH SO THAT If WILL HARMONIZE IN SERVICE AND APPEARANCE. 7. THE DRAWINGS INDICATE SIZE AND GENERAL LOCATION OF WORK. SCALED DIMENSIONS SHALL NOT BE USED. THE EXACT LOCATION AND ELEVATION OF DEVICES SHALL BE DETERMINED FROM THE ARCHITECTS DRAWINGS. 8. CUTTING AND PATCHING: A. ALL CUTTING AND PATCHING REQUIRED FOR EQUIPMENT INCLUDED IN THESE SPECIFICATIONS SHALL BE DONE BY THIS CONTRACTOR. IF CUTTING IS DONE DUE TO FAILURE TO PERFORM PRELIMINARY ROUGHING WORK, THIS CONTRACTOR WILL BE RESPONSIBLE FOR THE COST OF THE ADDITIONAL PATCHING. B. IN AREAS WHERE NEW WALLS OR PARTITIONS ARE REQUIRED THE CONTRACTOR SHALL FURNISH AND LOCATE ALL REQUIRED SLEEVES AND INSERTS BEFORE THE WALLS OR PARTITIONS ARE CONSTRUCTED. WHERE SLEEVES AND INSERTS WERE NOT INSTALLED OR WHERE SLEEVES AND INSERTS WERE INCORRECTLY LOCATED, THE CONTRACTOR SHALL BE RESPONSIBLE FORTHE COST OF ANY REQUIRED CUTTING AND PATCHING. C. THIS CONTRACTOR SHALL NOT DO ANY CUTTING THAT MAY IMPAIR THE STRENGTH OF BUILDING CONSTRUCTION. NO OUTLETS, SWITCHES OR SIMILAR DEVICES SHALL BE PERMITTED TO BE CHOPPED INTO ANY CORE WALL. NO HOLES, EXCEPT FOR SMALL SCREWS MAY BE DRILLED IN BEAMS OR OTFIER STRUCTURAL MEMBERS WITHOUT OBTAINING PRIOR APPROVAL. ALL WORK SHALL BE DONE IN A NEAT MANNER BY MECHANICS SKILLED IN THEIR -TRADES AND AS APPROVED. 9. RACEWAYS AND BOXES: A. NO OUTLETS OR SIMILAR DEVICES SHALL BE PERMITTED TO BE CHOPPED INTO ANY CORE WALL. B. WHERE SIZES OF RACEWAYS OR BOXES ARE NOT INDICATED, THE CONTRACTOR SHALL SIZE THESE ITEMS AS REQUIRED FOR THE INSTALLATION. C. ALL CONDUIT AND TUBING SHALL BE CUT SQUARE AND REAMED AT THE ENDS. RED LEAD SHALL BE APPLIED TO ALL EXPOSED THREADS AFTER JOINTS HAVE BEEN MADE UP CLEAN AND TIGHT. D. CONDUIT AND TUBING RUNS SHALL BE MECHANICALLY AND ELECTRICALLY CONTINUOUS FROM SERVICES STARTING TO ALL OUTLETS. CONDUIT SHALL ENTER AND BE SECURELY CONNECTED TO CABINET, JUNCTION BOX OR OUTLET BOX BY MEANS OF LOCKNUTS ON THE OUTSIDE AND INSIDE AND AN INSULATED BUSHING ON THE INSIDE. IN TUBING OR FLEXIBLE METAL CONDUIT, THE ONE COMPRESSION LOCKNUT SHALL BE MADE WRENCH -TIGHT. ALL LOCKNIJTS SHALL BE 'THE BONDING TYPE WITH SHARP EDGES FOR DIGGING INTO THE METAL ENCLOSURE AND SHALL BE INSTALLED IN SUCH A MANNER THAT WILL ASSURE A LOCKING AND ELECTRICALLY CONTINUOUS INSTALLATION. LOCKNUTS AND BUSHINGS WILL NOT BE REQUIRED WHERE CONDUITS ARE SCREWED INTO TAPPED CONNECTIONS. E. ALL VERTICAL RUNS OF CONDUIT OR TUBING TERMINATING IN THE BOTTOM OF WALL BOXES OR CABINETS OR SIMILAR LOCATIONS, SHALL BE PROTECTED FROM THE ENTRANCE OF FOREIGN MATERIAL PRIOR TO THE INSTALLATION OF CONDUCTORS. F. UNLESS OTHERWISE SPECIFIED, ALL CONDUIT AND TUBING SHALL BE INSTALLED CONCEALED. IN GENERAL, ALL CONDUIT AND TUBING SHALL BE RIJN IN HUNG CEILINGS AND FURRED SPACES WHERE THEY EXIST. WHERE CONDUIT IS RUN EXPOSED, IT SHALL BE SECURELY SUPPORTED WITH ZINC COATED MALLEABLE IRON PIPE STRAPS OR OTHER APPROVED METALS. G. EVERY CONDUIT SYSTEM SHALL BE INSTALLED COMPLETE BEFORE ANY CONDUCTORS ARE DRAWN IN. WIRE PULLING LUBRICANTS, WHEN UTILIZED, SHALL BE IN ACCORDANCE WITH THE REQUIREMENTS OF UNDERWRITER'S LABORATORIES, INC., APPLICABLE TO THE SPECIFIC CONDUCTOR OR CABLE INSULATION AND RACEWAY MATERIAL. I. MINIMUM CONDUIT SIZE SHALL BE 3/4". MAXIMUM SIZE FOR EMT IS 2". 10. FIRE ALARM SYSTEM: A. WHERE CONSTRUCTION INTERFERES WITH EXISTING FIRE ALARM EQUIPMENT, OR IT IS LOCATED ON EXISTING WALLS TO BE DEMOLISHED, IT SHALL BE THE RESPONSIBILITY OF THIS CONTRACTOR TO NOTIFY THE BUILDING OWNER AND RELOCATE IT AT 'THE OWNERS DIRECTION. DO NOT REMOVE F/A DEVICES UNLESS DIRECTED TO DO SO BY THE BUILDING. IT IS THIS CONTRACTOR'S RESPONSIBILITY TO MAINTAIN FIRE ALARM SPEAKERS, SMOKE DETECTORS AND OTHER FIRE SAFETY DEVICES IN OPERATION AT ALL TIMES. IF ANY PERMANENT BUILDING INSTALLATIONS SUCH AS SMOKE DETECTORS, CORRIDOR PA SYSTEMS, FIRE ALARM STATIONS, ELEVATOR SIGNS, LIGHTING IN ELECTRIC OR PORTERS CLOSETS, PIPE SHAFTS, ELECTRIC CABS, ETC. ARE TO BE ALTERED OR RELOCATED, THE BUILDING MANAGEMENT OFFICE SHALL BE NOTIFIED BEFORE PROCEEDING. THE ELECTRICAL CONTRACTOR MUST COORDINATE THE COMPLETE INSTALLATION WITH THE BUILDIN'S FIRE ALARM SYSTEM CONTRACTOR. THE ELECTRICAL CONTRACTOR MUST SUBMIT WIRING DAGRAMS (PRODUCED BY THE BASE BUILDING FA CONTRACTOR) TO THE ENGINEER FOR ANY MODIFICATIONS TO THE FIRE ALARM SYSTEM. THE ELECTRICAL CONTRACTORS BID SHALL INCLUDE TESTING BY THE BASE BUILDING FA CONTRACTOR. 11. OPENINGS AROUND ELECTRICAL PENETRATIONS THROUGH FIRE RESISTANCE RATED WALLS, PARTITIONS, FLOORS OR CEILINGS SHALL BE FIRE STOPPED USING APPROVED METHODS. 12. ALL WORK SHALL BE GUARANTEED AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE OF THE INSTALLATION. 13. FINAL CLEANUP AND FIELD TESTS: AFTER COMPLETION OF THE FINAL INSTALLATION: A. THE CONTRACTOR, BEFORE FINAL ACCEPTANCE WILL BE GRANTED, SHALL CLEAN ALL DEVICE PLATES AND ALL OTHER ITEMS INSTALLED UNDER THIS CONTRACT AND SHALL INSURE THAT ALL DIRECTORIES ARE IN PLACE WITH COMPLETED OR REVISED SCHEDULES AND ALL IDENTIFICATIONS AND MARKINGS OF EQUIPMENT, CABLES AND OTHER ITEMS ARE COMPLETED. B. THE CONTRACTOR SHALL REPAIR OR REPLACE AS DIRECTED BY THE ARCHITECT, AT NO ADDITIONAL COSI TO THE OWNER, ANY ITEM DAMAGED DUE TO INSTALLATION, RELOCATION OR REINSTALLATION. C. IN ADDITION TO OTHER TESTS WHICH MAY BE REQUIRED IN THE VARIOUS OTHER DISCIPLINES, THE CONTRACTOR SHALL PERFORM FIELD TESTS IN THE PRESENCE OF THE ARCFIITECT, TO DEMONSTRATE THE RELIABILITY OFTHE FIRE ALARM INSTALLATION. GIVE THE ARCHITECT 48 HOURS NOTICE IN ADVANCE OF SUCH TESTS. THE FOLLOWING FIELD TESTS SHALL BE PERFORMED BY THE CONTRACTOR: 1. SHOULD THE FOREGOING TENS REVEAL ANY DEFECTS, PROMPTLY CORRECT SUCH DEFECTS AND RERUN THE TESTS UNTIL THE ENTIRE INSTALLATION IS SATISFACTORY IN ALL KESPECTs. 14. THE CONTRACTOR SHALL PREPARE AND SUBMIT TO THE ARCHITECT FOR APPROVAL (6) SETS OF DETAILED SHOP DRAWINGS, CATALOG CUTS AND WIRING DIAGRAMS WHERE APPLICABLE. ANY SUBSTITUTIONS TO FIRE ALARM ITEMS DESCRIBED ON THIS CONTRACTOR WILL ONLY BE PERMITTED UPON WRITTEN APPROVAL BY THE ARCHITECT. SHOP DRAWINGS AND CATALOG CUTS WILL BE REQUIRED FOR THE FOLLOWING: A. FIRE ALARM DEVICES. 1. NO PVC CONDUIT ALLOWED. 2. ALL REUSED DEVICES TO BE RECERTIFIED. FIRE ALARM NOTES: 1 FA CONTRACTOR SHALL REUSE THE EXISTING FIRE ALARM DEVICES AND RELOCATE THEM AS SHOWN ON THE DRAWINGS. NEW DEVICES SHALL BE INSTALLED AS NEEDED TO MATCH THE EXISTING AS REQUIRED. 2 THE BUILDING FIRE ALARM SYSTEM CONTRACTOR, (FIELD VERIFY AIRPORT SYSTEM) SHALL SUPPLY AND INSTALL A COMPLETE EXTENSION OF THE EXISTING FIRE ALARM SYSTEM, INCLUDING ALL NECESSARY WIRING. THE FA CONTRACTOR SHALL BE EMPLOYED BY THE TENANT'S GC TO PREFORM THE INSTALLATION AND CONNECTION. 3 THE FA CONTRACTOR SHALL PROVIDE DRAWINGS AS REQUIRED AND HIS BID SHALL INCLUDE TESTING AND DEMOSTRATING THE OPERATION OF THE SYSTEM TO THE PORT AUTHORITY. 4 THE FA CONTRACTOR SHALL BE RESPONSIBLE FOR THE START-UP AND PROPER OPERATION OF THE FIRE ALARM SYSTEM. 5 WALL MOUNTED DEVICES SHALL BE MOUNTED AT 80" AFF OR 6" BELOW THE FINISHED CEILING WHICHEVER IS LOWER. 6 ALL FA DEVICES AND FA JUNCTION BOXES SHALL BE IDENTIFIED IN ACC- ORDANCE WITH NFPA STANDARD 70. TERMINAL BOXES SHALL BE PAINTED RED AND STENCILED IN WHITE LETTERS "FIRE ALARM". 7 FA CONDUITS SHALL ENTER ONLY AT THE SIDES OR BOTTOM OF THE FIRE ALARM TERMINAL BOXES. 8 ALL WIRING TYPES SHALL BE COORDINATED WITH THE BUILDING'S FA MAINTENANCE CONTRACTOR AND SHALL BE APPROVED BY THE LOCAL FIRE DEPARTMENT AND ALL AUTHORITIES HAVING JURISDICTION. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 OWNER REVISION ADJACENT RESTAURANT FIRE ALARM PLAN 1/W' =1'-0" I3udson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN ELECTRICAL SYMBOLS AND LEGEND L[�] FIRE ALARM HORN/STROBE O0 FIRE ALARM STROBE J� JUNCTION BOX - SHALL BE ACCESSIBLE AFTER COMPLETION OF CONSTRUCTION CONNECTION TO PANELBOARD - SUBSCRIPT DENOTES PANEL DESIGNATION NOTE: ALL FIRE ALARM DEVICES ARE CLASS "B" RATED. FA CONTRACTOR SHALL VERIFY WITH THE DOA FOR THE FIRE ALARM MANUFACTURER BEING USED FOR THE EXISTING FIRE ALARM SYSTEM PRIOK TO PURCHASE. N NOTE- TO CONTRACTOR: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE TO VERIFY FIELD CONDITIONS FOR HIS PARTICULAR TRADE. IF THERE ARE DISCREPANCIES IN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS THEN THE CONTRACTOR SHALL PREPARE A BIDD BASED ON ACTUAL FIELD CONDITIONS AND IMMEDIATLY INFORM THE ARCHITECT IN WRITING OF THE THE DIS .REPANCIES. IF JOBSTTE IS NOT VISITED PRIOR TO BIDDING THEN THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ABOVE MENTIONED DISCREPANCIES. -------------- I � I I I I \ I I \ I I \ APPROVED AIRPORT FIRE ALARM I I \ CONTRACTOR SHALL CONNECT TO I I \� THE EXISTING AIRPORT FIRE ALARM I I \ SYSTEM AS REQUIRED BY THE DOA. I I � I 0 \ \ I 1 \ I 1 1 ( I 1 I I 0 11 i I 1----------------,------- -----� I 1 I II I 0 `I I II I � II I 01� it I ' I 0 I / / I 0 TERMINAL A INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SAN FORD INTERNATIONAL_ AIRPORT SANFORD, FLORIDA DON PENN, P.E. FLORIDA ENGINEER NO. 0051096 (MECH) 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817-410-2858 FAX 817-251-8411 DRAWN DATE JVP CHECKED JOB NUMBER DP 06,14 E-1.3 SION EVI v II IIII I It 11 LL_ - IF I II III L__ I I / / F- IF 111 IIIIJI� Iii / / r=r•1 // �1I I I —Ili III MI / ,/J �Li—Li I II IIII I II L �I— // rT � I I I I // / II u 7 it 79 I III IIII II 1 II IIII 11 k /��LLL / / +4 +8 / I V / � /II I 1 1 III IIII II // / /� LIL-2 / I // III IIII II IIIIII I III 111111 // / /10 1 11 III} III III LIQ I2 1 / / / / / EEE 1 I �_-�=J11 - J / 0 — T I 1= EE A F I T—I Ij I j 10 I I I F I 1 I 1 0 I 1 I 0 I F-'� \ I I II I I II II 1 \1 0 1 uI I � ] III --- -- I 1 — --- +8 F h - " ADJACENT RESTAURANT FIRE ALARM PLAN 1/W' =1'-0" I3udson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN ELECTRICAL SYMBOLS AND LEGEND L[�] FIRE ALARM HORN/STROBE O0 FIRE ALARM STROBE J� JUNCTION BOX - SHALL BE ACCESSIBLE AFTER COMPLETION OF CONSTRUCTION CONNECTION TO PANELBOARD - SUBSCRIPT DENOTES PANEL DESIGNATION NOTE: ALL FIRE ALARM DEVICES ARE CLASS "B" RATED. FA CONTRACTOR SHALL VERIFY WITH THE DOA FOR THE FIRE ALARM MANUFACTURER BEING USED FOR THE EXISTING FIRE ALARM SYSTEM PRIOK TO PURCHASE. N NOTE- TO CONTRACTOR: PRIOR TO BIDDING THE CONTRACTOR SHALL VISIT THE JOBSITE TO VERIFY FIELD CONDITIONS FOR HIS PARTICULAR TRADE. IF THERE ARE DISCREPANCIES IN THE CONTRACT DRAWINGS AND ACTUAL FIELD CONDITIONS THEN THE CONTRACTOR SHALL PREPARE A BIDD BASED ON ACTUAL FIELD CONDITIONS AND IMMEDIATLY INFORM THE ARCHITECT IN WRITING OF THE THE DIS .REPANCIES. IF JOBSTTE IS NOT VISITED PRIOR TO BIDDING THEN THE CONTRACTOR WILL BE HELD RESPONSIBLE FOR ABOVE MENTIONED DISCREPANCIES. -------------- I � I I I I \ I I \ I I \ APPROVED AIRPORT FIRE ALARM I I \ CONTRACTOR SHALL CONNECT TO I I \� THE EXISTING AIRPORT FIRE ALARM I I \ SYSTEM AS REQUIRED BY THE DOA. I I � I 0 \ \ I 1 \ I 1 1 ( I 1 I I 0 11 i I 1----------------,------- -----� I 1 I II I 0 `I I II I � II I 01� it I ' I 0 I / / I 0 TERMINAL A INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SAN FORD INTERNATIONAL_ AIRPORT SANFORD, FLORIDA DON PENN, P.E. FLORIDA ENGINEER NO. 0051096 (MECH) 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817-410-2858 FAX 817-251-8411 DRAWN DATE JVP CHECKED JOB NUMBER DP 06,14 E-1.3 SION EVI ELECTRICAL_ MATERIALS & METHODS: INSTRUCTION TO BIDDERS: 1. CONTRACTOR SHALL BASE HIS PROPOSAL FOR HIS WORK ONLY AFTER VISITING THE JOBSITE FOR ACTUAL JOB CONDITIONS WHICH MAY AFFECT WORK COVERED BY THESE SPECIFICATIONS. SUBMITTALS: 1. SUBMIT SHOP DRAWINGS & PRODUCT INFORMATION FOR THE FOLLOWING: * SERVICE & DISTRIBUTION EQUIPMENT * PROTECTIVE DEVICES LIGHTING FIXTURES AND LAMPS * WIRING DEVICES AND COVER PLATES DISTRIBUTION EQUIPMENT: 1. DISTRIBUTION EQUIPMENT; RATED FOR 240 OR 600 VAC, 60 HZ, FAULT CURRENT INTERRUPTING CAPACITY AS INDICATED, IN AMPERES, RMS, SYMMETRICAL, BUT NOT LESS THAN 10,000 AMPS, WITH SOLID NEUTRAL GROUND (S/N); GENERAL ELECTRIC (G.E.), WESTINGHOUSE, SQUARE -D, SIEMENS-ALLIS ITE PRODUCTS, CUTLER HAMMER. 2. DISTRIBUTION EQUIPMENT USING CIRCUIT BREAKER TYPE PROTECTIVE DEVICES; BOLTED -ON OR 'SQUARE D' [-LINE DEVICES. 3. PANELBOARDS; FACTORY ASSEMBLED, MINIMUM WIDTH OF 20 INCHES, A MINIMUM DEPTH OF 5-3/4 INCHES, AND MINIMUM MAINS RATED 100 AMPERES, WITH POLE 'SPACES'; BUSSED AND READY FOR INfALLATIQN OF PROTECTIVE DEVICES. CABINETS; FULL SIZED SINGLE DOORS WITH CHROMIUM PLATED COMBINATION CYLINDER LOCK AND CATCH AND TWO KEYS. "GENERAL ELECTRIC" OR EQUAL: TYPE "NLAB" W/ Q -LINE BRANCH CIRCUIT- BREAKERS; TYPE "NI -113" WITH E -FRAME BREAKERS. 4. PANELBOARD MAINS; COPPER OR ALUMINUM WITH BRANCH CONNECTIONS IN VERTICALLY DISTRIBUTED CONSECUTIVE PHASE SEQUENCE SUCH THAT ONE OR MULTIPLE POLE BREAKERS CAN BE MOUNTED IN ANY POSITION. SOLID NEUTRAL BUS; WITH A FEEDER LUG AND WITH A SEPARATE SET -SCREW TERMINAL FOR EACH BRANCH CIRCUIT POLE. S. PANELBOARD MOUNTING; TOP OF ENCLOSURE 78 INCHES ABOVE THE FINISHED FLOOR/GRADE, WITH THE BOTTOM OF THE CABINET NOT CLOSER THAN 6 INCHES TO THE FLOOR/GRADE, PROPERLY ALIGNED AND SUPPORTED INDEPENDENTLY OF THE CONNECTING RACEWAYS. COMPLETE INSIDE CIRCUIT DIRECTORY CARD USING A TYPEWRITER. 6. DISCONNECT SWITCHES; 'HEAVY-DUTY' RATED WITH QUICK -MAKE AND QUICK -BREAK MECHANISMS. PROVIDE GROUND LUGS AND CODE REQUIRED ACCESSORIES. SWITCHES LOCATED OUTSIDE; 'NEMA -3R' ENCLOSED TYPE WITH LOCKING HASP. 7. PROVIDE AN ENCLOSED SWITCH FOR ELECTRICALLY SERVED EQUIPMENT. PROVIDE SWITCHES & FUSES, INCLUDING HEATER ELEMENTS, RATED PER THE CHARACTERISTICS AND NAMEPLATE RATINGS OF EQUIPMENT IN ACCORDANCE WITH CODE REQUIREMENTS, MANUFACTURER'S RECOMMENDATIONS AND CHARTS. PROVIDE SWITCHES WITH CODE REQUIRED ACCESSORIES. 8, FUSED SWITCHES IN BRANCH CIRCUITS; NON-RENEWABLE CARTRIDGE FUSES RATED 250 OR 300 VAC OR 600VAC AS FOLLOWS: * SIZES 'I - 200 AMPS: DUAL ELEMENT, CURRENT LIMITING FUSES, CLASS 'RK -1', OR 'RK -5', SELECTED TO PROVIDE STARTING AND LIMIT LET-THRU CURRENT. * OTHER RATINGS, SIZES OR SPECIAL APPLICATIONS AS INDICATED. 9. STATIONARY FRACTIONAL HORSEPOWER MOTORS NOT PROVIDED WITH INTEGRAL MOTOR RUNNING OVF-RLOAD PROTECTION, OR INHERENTLY PROTECTED BY DESIGN; SWITCHED BY A FRACTIONAL HORSEPOWER STARTER PROVIDING SUPPLEMENTARY PROTECTION. 10. STARTERS AND DISCONNECT SWITCHES; ENCLOSED QUICK -MAKE AND QUICK -BREAK MECHANISMS. 11. BRANCH CIRCUIT BREAKERS; MOLDED CASE, AUTOMATIC TRIPPING TYPE, BOLT -ON OR I -LINE CONSTRUCTION, MINIMUM FRAME SIZE OF '100 AMPS AND A MINIMUM TRIP SIZE OF '15 AMPS, CALIBRATED FOR 40oC. PROVIDE SUITABLE TYPE BREAKERS SERVING HIGH INRUSH CIRCUITS FOR INCANDESCENT LIGHTING. '12. GROUP SINGLE -POLE BREAKERS USED FOR MULTI -WIRE CIRCUITS CONSECUTIVELY ON THE SAME SIDE OF THE CABINET. CONDUCTORS: 1 . CONDUCTORS; SOFT DRAWN, ANNEALED COPPER WITH CONDUCTIVITY OF NOT LESS THAN 98 % BY 'ASTM' STANDARDS. 2. CONDUCTOR SIZE NUMBERS; AMERICAN WIRE GAUGE (AWG. SYSTEM, STANDARD TRADE SIZES. 3. CONDUCTORS; COLOR CODED PER CODE AND UTILITY CO. 4. CONDUCTORS; No. 12 AWG SIZE AND SMALLER; SOLID. h NoA 0 AWG SIZE; SOLID OR STRANDED. * No.8 AWG SIZE AND LARGER; STRANDED. STRANDED CONDUCTORS; CLASS B' OR 'C'. * CONTROL CIRCUITS; MINIMUM AWG No. 14. * POWER AND LIGHTING BRANCH CIRCUITS; AWG # 12 FOR GENERAL CIRCUITS NOT REQUIRING DERATING OR SIZE INCREASE TO REDUCE VOLTAGE DROP. * CODING AS INDICATED: 120/208 VOLT- SYSTEM: PHASE A -BLACK PHASE B -RED PHASEC-BLUE NEUTRAL -WHITE GROUND -GREEN 277/480 VOLT SYSTEM: PHASE A -BROWN PHASE B -ORANGE PHASE C -YELLOW NEUTRAL -WHITE W/TRACER GROUND -GREEN 5. USE A SPERATE LUG FOR EACH CONDUCTOR WHERE MULTIPLE CONDUCTORS ARE CONNECTED TO THE SAME ELECTRICAL TERMINAL POSITION 6. FEEDER CONDUCTORS (TO INCLUDE SUB -FEEDER); IJNSPLICED THROUGHOUT "THEIR LENGTH. 7. BRANCH CIRCUIT CONDUCTORS; UNSPLICED EXCEPT WHERE CIRCUITS ARE SHOWN TO DIVIDE BY THE PLANS. 8. GENERAL WIRING CONDUCTORS OPERATING AT 600 VOLTS AND BELOW; RATED 60 HERTZ, 600 VOLTS, WITH 75oC OR 90oC INSULATION AS FOLLOWS: A. FEEDER CONDUCTORS: RATED FOR WET LOCATIONS OF 'THW% . 'TFIWN' OR 'XHHW'. B. BRANCH CONDUCTORS RATED FOR: * WET LOCATIONS, OR LOCATIONS LOCATED BELOW GRADE OR ENCASED IN SLAB ON GRADE, OF 'THW', 'THWN' OR 'XHHW'. * DRY LOCATIONS OF 'THW', 'THWN', 'XHHW' OR 'THHN'. C. RATED LIGHTING CONDUCTORS FOR CIRCUITS REQUIRING 900C RATING; 'THHN' OR 'XHHW', OR OTHER APPROVED TYPE. D. JOINTS ON CONDUCTORS RATED ABOVE 75oC; TAPED OR MADE-UP WITH MATERIALS HAVING A SUITABLE HIGH TEMPERATURE RATING. RACEWAYS: 'I. INSTALL WIRING IN METALLIC, RIGID TYPE RACEWAYS. 2. RUN RACEWAYS AND CABLE CONCEALED, EXCEPT RACEWAYS IN EQUIPMENT ROOMS RUN EXPOSED. 3. RACEWAYS IN ORDINARY LOCATIONS: * BURIED BELOW GRADE OR SLAB; SCH. 40 PVC CONDUIT, EXCEPT WHERE SCH. 80 IS REQUIRED BY THE UTILITY CO. OR CODE DUE TO INSTALLATION CONFIGURATION. * INSIDE (NOT IN WET OR DAMP LOCATIONS OR EXPOSED TO MECHANICAL INJURY); STEEL, ELECTRICAL METALLIC TUBING (EMT). * EXPOSED OUTSIDE, THROUGH OUTSIDE WALL OR ROOF, OR THROUGH TWO-HOUR OR MORE RATED FIRE BARRIERS; GALVANIZED RIGID STEEL (GRS) CONDUIT MADE UP WATER TIGHT. FINAL CONNECTION IN DRY LOCATIONS SERVING LIGHTING FIXTURES; FLEXIBLE METAL CONDUIT OR FLEXIBLE METALLIC TUBING. CONNECTIONS TO MOTORS, OR TO COMPONENTS IN WET OR DAMP LOCATIONS, LIQUIDTIGHT FLEXIBLE METAL CONDUIT (LT FLEX). 4. RIGID STEEL GRS, AND STEEL IMC; HOT DIP GALVANIZED 5. STEEL EMT; HOT DIP GALVANIZED OUTSIDE, AND ENAMEL OR GALVANIZED FINISHED INSIDE. 6. EMT COUPLINGS AND CONNECTORS; METAL AS FOLLOWS: * RAINTIGH T, HEX -NUT, EXPANSION- GLAND COMPRESSION STEEL, FOR ANY WET OR DAMP LOCATION OR FEEDER (OR SUB -FEEDER.. SET -SCREW OR TAP -ON, STEEL OR CAST METAL, FOR DRY LOCATIONS. 7. CIRCULAR RACEWAYS; MINIMUM TRADE SIZE AS FOLLOWS: 3/4 -INCH; 'HOMERUN' CIRCUIT WIRING; MORE THAN (3) CONDUCTORS. 8. SIZE RACEWAYS TO ACCOMMODATE THE ENCLOSED CONDUCTORS. 9. PROVIDE JUNCTION OR PULL BOXES TO AVOID EXCESSIVE RUNS OR BENDS BETWEEN OUTLETS, AND AT LOW POINTS IN RACEWAY RUNS, 10. SUPPORT CONCEALED CONDUIT ABOVE THE CEILING INDEPENDENTLY OF CEILING CONSTRUCTION. INSTALL CONDUITS HIGH ABOVE LAY -IN CEILINGS TO PERMIT REMOVAL OF CEILING PANELS OR EQUIPMENT. INS -FALL EXPOSED RACEWAYS PARALLEL OR PERPENDICULAR TO STRUCTURAL MEMBERS AND ARCHITECTURAL FEATURES. INSTALL CONCEALED CONDUIT RACEWAYS WITH AS FEW BENDS AS FEASIBLE, COORDINATED WITH STRUCTURAL, MECHANICAL AND ARCHITECTURAL REQUIREMENTS. ROUTE RACEWAYS TO AVOID 'TRAPPING' WHERE PRACTICABLE. ENCLOSURES AND BOXES: 1. EQUIPMENT ENCLOSURES, BOXES, & COVERS; GALVANIZED STEEL, MALLEABLE IRON, GRAY IRON, OR COPPER -FREE ALUMINUM. SCREWS; STAINLESS STEEL; ALUMINUM FOR ALUMINUM BOXES. 2. ENCLOSURES: " FLUSH MOUNTED WITH CONCEALED RACEWAYS OR FLUSH MOUNTED DEVICES. * SURFACE MOUNTED TYPE IN EQUIPMENT ROOMS, WITH EXPOSED RACEWAYS AND OTHER SURFACE MOUNTED DEVICES. 3. BOXES FOR USE WITH GENERAL RACEWAY SYSTEMS; 4 INCHES SQUARE OR OCTAGONAL SIZE, NOT BE LESS THAN 1-1 /2 INCHES DEEP, EXCEPT WHERE SHALLOWER BOXES ARE REQUIRED BY STRUCTURAL CONDITIONS. 4 BY 2 INCH BOXES; WHERE ONLY ONE RACEWAY ENTERS AN OUTLET BOX, OR WHERE NEEDED TO MATCH DEVICES AND/OR MOUNTING HARDWARE. 4. DO NOT USE SUSPENDED CEILING CONSTRUCTION TO SUPPORT RACEWAYS, BOXES OR OTHER ITEMS, EXCEPT AS ALLOWED BY CODE AND ACCEPTED BY THE ARCHITECT IN WRITING. DEVICES: 1. SWITCHES; STANDARD LINE STYLE, MAINTAINED, 15 OR 20 AMPS, 120- "277 VAC, QUIET OPERATING, FLUSH MOUNTING, BY LEVITON, 'SPEC - MASTER, COMMERCIAL SPEC. GRADE' SERIES, HUBBELL OR ARROW HART. 2. RECEPTACLES; STANDARD LINE STYLE, STRAIGHT BLADE, 2 -POLE, 3 - WIRE GROUNDING TYPE, RATED'125 VAC, 15 OR 20 AMPS, BY LEVITON, 'SPECMASTER, 'COMM. SPEC. GRADE' SERIES, HUBBELL OR ARROW HART. 3. DIMMER SWITCHES; RATED FOR FULL RANGE DIMMING OF 120 VAC LOADS, EITHER FLUORESCENT OR INCANDESCENT, KNOB OR SLIDE CONTROLLED W/ FULL OFF POSITION, FLUSH MOUNTABLE IN STANDARD 1 -GANG OR 2 -GANG BOXES. ARCHITECTURAL' STYLE, THIN PROFILE TYPES, BY LEVITON, 'COMM. SPEC. GRADE' SERIES, LUTRON OR LITHONIA. 4. GROUND FAULT CIRCUIT INTERRUPTED (GFCI) RECEPTACLES; U.L. LISTED FOR PERSONNEL PROTECTION AGAINST LINE -TO- GROUND SHOCK HAZARD. GFCI RECEPTS.; DUPLEX, 'DECORA STYLE' BY LEVITON, 'COMM. SPEC. GRADE', HUBBELL OR ARROW HART. S. KEYLESS LAMPHOLDER: WHITE PORCELAIN, 660 WATTS AT 250 VOLTS; LEVITON, CAT. No. 9875-2. 6. COVER PLATES: FOR FLUSH, INSIDE, WALL MOUNTED DEVICES; LEVITON. 7. INSTALL WIRING DEVICES WITH TOP -OF -BOX MOUNTING HEIGHTS ABOVE FINISHED FLOORS AS FOLLOWS: FOR RECEPTACLES 18 INCHES AND 48 INCHES FOR SWITCHES AS REQUIRED BY HANDICAPPED CODES. THIS DRAWING AS AN INSTRUMENT OF SERVICE, IS AND SHALL REMAIN THE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THERE OF, WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 LIGHTING: 1. FLUORESCENT BALLASTS; HIGH POWER FACTOR (HPF) TYPE, CLASS 'P' PROTECTED, SOUND RATING •A', AND ENERGY SAVING TYPE. 2. FLUORESCENT BALLASTS FOR THE MINI -LAMPS; U.L. LABELED OR ACCEPTABLE TO BUILDING OFFICIALS, ENCAPSULATED, QUIET OPERATING DESIGN IF AVAILABLE. 3. ORIENT FLUORESCENT LAMPS WITHIN THE SAME VISUAL SPACE IN THE SAME DIRECTION. GROUNDING: 1. GROUND ELECTRICAL SYSTEMS, EQUIPMENT, AND SUPPORTING STRUCTURES. PROVIDE BONDING JUMPERS WHERE NECESSARY. MECHANICALLY AND ELECTRICALLY SECURE METAL RACEWAYS AND FITTINGS, JOINTS AND CONNECTIONS AT EQUIPMENT TO PROVIDE AN GROUNDING MEANS. METAL RACEWAYS; ELECTRICALLY CONTINUOUS THROUGHOUT THEIR LENGTH FOR AN EFFECTIVE GROUNDING PATH TO THE POWER SERVICE DISCONNECT SWITCH. 2. INSTALL GROUNDING CONDUCTORS WITHOUT JOINT OR SPLICE TO THE GREATEST PRACTICAL EXTENT. 3. PROVIDE FOR EACH RACEWAY A GREEN #12 GROUNDING CONDUCTOR IN ADDITION TO BRANCH CONDUCTORS INDICATED. 4. DO NOT SPLICE MAIN BONDING JUMPER. CONFIRM THAT A MAIN BONDING JUMPER IS PROVIDED AT THE POINT OF SERVICE ONLY. 5. GROUND BOTH NEUTRAL AND GREEN ISOLATED GROUNDING TYPE CONDUCTORS FOR ISOLATED GROUNDING CIRCUITS AT ONE POINT OF GROUND OF SEPARATELY DERIVED ELECTRICAL SYSTEM. TESTING: 1. TEST INDIVIDUAL SYSTEMS AND COMPONENTS FOR FULL FUNCTIONAL REQUIREMENTS. PERFORM TESTS AS REQUIRED BY CODE, LOCAL PRACTICES, OR AS REASONABLY REQUIRED BY THE OWNER'S REPRESENTATIVE WHERE A QUESTION ARISES AS TO THE PROPER INSTALLATION OR OPERATION OF MATERIALS. 2. PROVIDE TESTING INSTRUMENTS, PROCEDURES, AND DOCUMENTATION. MISCELLANEOUS: 1. MAJOR COMPONENTS OF THE DISTRIBUTION SYSTEM SUCH AS THE PANELBOARD, DISCONNECT SWITCHES... ETC. SHALL HAVE PERMANENT NAMEPLATES FOR EQUIPMENT IDENTIFICATION. PROVIDE NAMEPLATE ON SERVICE DISCONNECT IN "TDP" PANEL AND POWER COMPANY METER TO INDICATE TENANT SPACE NUMBER AND SPACE LEVEL. 2. IN RACEWAY OR CABLE, ETC. THAT PENETRATES A FIRE BARRIER, WITH MATERIALS AND METHODS APPROVED FOR APPLICATION BY BUILDING OFFICIALS. IDENTIFY EACH FIRE BARRIER FROM THE ARCHITECTURAL PLANS, AND FOR SECURE APPROVAL OF MATERIALS AND METHODS FOR EACH TYPE PENETRATION. 3. ROOF PENETRATIONS SHALL BE COORDINATED WITH LANDLORD'S REPRESENT- ATIVE. ALL ROOF CUTTING/PATCHING SHALL EB BY LANDLORD'S ROOFING CONTRACTOR AT TENANT'S EXPENSE, 4. PROVIDE APPROVED "MEANS OF DISCONNECT" FOR STOREFRONT SIGN(S). 5. PROVIDE NAMEPLATES FOR ALL ROOF MOUNTED DISCONNECT SWITCHES. WITH SPACE NAME, NUMBER AND MALL LEVEL INFORMATION. 6. PROVIDE ACCESS PANELS AT ALL LANDLORD INSTALLED ELECTRICAL DEVICES AND EQUIPMENT ABOVE HARD CEILINGS. ACCESS PANELS TO BE SIZED IN THE FIELD FOR EACH APPLICATION. TELEPHONE SYSTEM ROUGH -IN: 1. PROVIDE COMPLETE ENCLOSED RACEWAYS WITH MEASURED PULL CORDS FOR FUTURE USE BY OTHERS. PROVIDE A 1 " CONDUIT FROM LANDLORD'S MAIN TERMINAL LOCATION TO TENANT'S SPACE. TEMPORARY WIRING DURING CONSTRUCTION: 1. PROVIDE TEMPORARY ELECTRICAL DISTRIBUTION WIRING AND RELATED SERVICES AS REQUIRED. 2. PAY THE COST OF ELECTRICITY FOR THE TEMPORARY SERVICE WHERE THE LANDLORD DOES NOT PAY DIRECTLY FOR THESE UTILITY SERVICES. T VERIFY u ANGLE 3"x3"x1/2" (L.L.V.) WELD TO BOTTOM CHORD OF EXIST. JOIST (2 READ.) ANGLE3"x3"x1 /2" (L:L.V.) MINIMUM OF 96"AFF 2 -REQUIRED. STEEL ABOVE -E -<TYP. RODS THRD. EACH (4 READ.) 4TION ISOLATORS UND OR EQUAL TRANSFORMER MOUNTING DETAIL NTS NO. DATE REVISION 1 2-22-09 OWNER REVISION 0 PANELBOARD SCHEDULE "L" MAINS: 100 A MCB VOLTAGE: 120/208V PHASE: 3 WIRE: 4 MOUNTING: SURFACE CIRC. NO. 'TRIP POLE DESCRIPTION CONNECTED LOAD (KVA) DESCRIPTION TRIP POLE CIRC. NO PHASE A PHASE B PHASE C 1 20/1 SALES LIGHTING 1.5 1.6 OPEN FACE COOLER 20/2 "2 3 20/1 SALES LIGHTING 1.3 1.6 4 5 20/1 ENTRY DN. LTS. (VIA TC 8 1.6 OPEN FACE COOLER 20/2 6 7 20/1 WALL CASE LTS. 1.8 1.6 8 9 20/1 WALL CASE LTS. 1.8 .8 RECEPT/FUT. TV 20/1 10 1 1 20/1 WALL CASE LTS. 1.8 1.6 FUTURE OPEN FACE COOLER 20/2 '12 13 20/1 CASH REGISTER .8 1.6 14 15 20/1 CASH REGISTER .8 .8 SIGNS (VIA TC) 20/1 16 17 20/1 CASH REGISTER .8 .6 DIGITAL PROC/TV 20/1 18 19 20/1 CASH REG. IG QUADS 1.2 X SPARE 20/1 2U 21 20/1 TELEPHONE .2 X SPARE 20/1 22 23 20/ l LTG. CONTACTOR 2 X SPARE 20/1 24 25 20/ 1 TIME CLOCK .2 X SPACE 1 P 26 27 IP SPACE X X SPACE 1P 28 29 '1P SPACE X X SPACE 1P 30 MIN. BREAKER A.I.C. 10,000 10.3 7.3 7.4 TOTAL CONNECT LOAD: 2 5. 0 KVA TOTAL DEMAND LOAD: 20.5 INA NOTE: ALL LIGHTING CIRCUITS TO BE ROUTED THRU THE LIGHTING CONTACTOR(S) AS REQUIRED. CONTRACTOR SHALL PROVIDE A 1 1 5 DEG- REE HIGH EFFENECY TRANSFORMER AS REQUIRED BY THE AIRPORT AUTHORITY. #8(G) TO BLDG. STEEL AND MAIN METAL COLD WATER PIPE 3 #8, 1 #10(G), 3/4"C T 30 KVA II 480-208 3 PH 4 #2, 1 #8(G), 1-1/4"C NOTE TO CONTRACTOR: WHEN THE CONTRACTOR OBSERVES ERRORS, DISCREPANCIES, OMISSIONS OR AMBIGUTIES IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL IMMEDIATLEY, IN WRITING, REFER SAME TO THE ARCH- ITECT FOR THE ARCHITECT'S WRITTEN INTERPRETATION OR CORRECTION. IF CONTRACTOR SHALL FAIL TO GIVE NOTICE OF SUCH WORK BEFORE CONSTRUCTION OR FABRICATION OF THE WORK, CONTRACTOR WILL BE HELD RESPONSIBLE FOR THE RESULT OF SUCH ERROR, DISCREPANCY OR OMISSION. PNL" L" 1 20/208V, 3PH, 4W 100 AMP MCB I 60/3/NF 1 " CONDUIT WITH PULL - CORD TO AIRPORTS NEAREST MAIN TELEPHONE BACKBOARD AS REQUIRE _�. TELEPHONE BACKBOARD TENANT'S AIRPORTS ELECTRICAL SPACE ROOM TIME CLOCK LIGHTING CONTACTOR 14 ELECTRICAL L RISER DIAGRAM SCALE: NONE a A j I Hudson News Hudson booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SANFORD INTERNATIONAL AIRPORT SANFORD, FLORIDA 3 #8, 1 #10(G), 3/4"C NOTE: CONDUIT AND CONDUCTORS ARE SIZED FOR 200'-0", IF THE DIS- TANCE FROM TENANT PANEL TO AIRPORT PANEL IS GREATER THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR THE RESIZING OF CONDUIT AND CONDUCTORS PRIOR TO BIDING. (50/3) AIRPORT PNL 277/48OV, 3PH, 4W CONTRACTOR SHALL FIELD VER- IFY THE LOCATION OFTHE 480V/3PH PANEL THAT WILL BE SERVING THE SPACE AND THE ROUTING OF CONDUIT AND CONDUCTORS TO THE SPACE PRIOR TO BIDDING. DON PENN, P.E. FLORIDA ENGINEER N0. 0051096 (MECH) 635 WESTPORT PARKWAY, SUITE 300 GRAPEVINE, TEXAS 76051 817-410-2858 FAX 817-251-8411 DRAWN DATE JVP CHECKED JOB NUMBER DP 0314 HVAC SPF_CIFICATIONS.4 SCOPE OF WORK: 'I. SCOPE OF WORK FOR THE PROJECT SHALL CONSIST OF PROVIDING ALL LABOR, MATERIAL, EQUIPMENT, HOISTING AND OTHER ITEMS AS NECESSARY FOR A COMPLETE OPERATIONAL HVAC SYSTEM. 2. MECHANICAL CONTRACTOR SHALL VISIT- THE SITE PRIOR TO PROVIDING; BIDS AND COMMENCEMENT OF WORK AND SHALL FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS SO THAT ANY CONDITIONS READILY VISIBLE TO THE EYE WHICH RELATES TO HIS WORK SHALL BE PROVIDED FOR AT NO ADDITIONAL EXPENSE TO THE OWNER. 3. ALL WORK SHALL BE INSTALLED IN A PROFESSIONAL MANNER, AND THE ARCHITECT RESERVESTHE RIGHT 'TO HAVE CONTRACTOR REMOVE AND REPLACE OR REPAIR ANY WORK WHICH IS DEEMED INFERIOR TO ACCEPTABLE STANDARDS. 4. ALL WORK SHALL CONFORM TO THE 2006 INTERNATIONAL MECHANICAL CODE AND WITH THE 2006 FLORIDA BUILDING CODE, AIRPORT AUTHORITY AND LOCAL OFFICALS TO INCLUDE THE LOCAL ENERGY CODE. CONTRACTOR SHALL PROVIDE FOR ALL PERMITS, FEES AND OTHER COSTS ASSOCIATED WITH LOCAL JURISDICTION HAVING AUTHORITY. 5. CONTRACTOR SHALL SCHEDULE HIS WORK AS FAST AS THE JOB SCHEDULE PERMITS SO AS TO NOT HINDER THE WORK OF OTHER TRADES. 6. NO EQUIPMENT SHALL BE OPERATED DURING CONSTRUCTION UNTIL SUCH TIME AS CONTRACTOR IS NOTIFIED THAT SYSTEMS ARE READY TO BE STARTED FOR FINAL DELIVERY TO THE OWNER. PRODUCTS: I. PRODUCTS FOR THE LAYOUT BASIS HAVE BEEN SELECTED FROM A SINGLE MANUFACTURER. CONTRACTOR MAY AT HIS OPTION PROVIDE EQUIPMENT OF ANOTHER MANUFACTURER PROVIDED HE ENSURES THAT HIS SELECTION WILL FIT WITHIN THE SPACE PROVIDED. 2. ALL EQUIPMENT SHALL BE NEW AND SHALL BE PROVIDED WITH A FULL MANUFACTURER'S WARRANTY EXTENDED TO THE OWNER. 3. SPECIAL ATTENTION SHALL BE PROVIDED TO VOLTAGE REQUIREMENTS OF EQUIPMENT. CONTRACTOR SHALL COORDINATE REQUIREMENTS WITH ELECTRICAL BEFORE ORDERING OR INSTALLING. AIR DISTRIBUTION: 1. INSTALL A NEW AIR DISTRIBUTION SYSTEM PER PLANS AND SPECIFICATIONS. DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH JOINTS SEALED WITH DUCT MASTIC PER MANUFACTURER RECOMMENDATIONS. 2. WRAP ALL DUCTWORK WHICH WILL BE CONCEALED AFTER BUILDING FINISHES WITH FOIL -FACE 2" THICK DUCT WRAP WITH JOINTS LAPPED AND STAPLED. ALL DUCTWORK TO BE EXPOSED UPON COMPLETION OF BUILDING FINISHES SHALL BE INTERNALLY LINED WITH '1 " THICK DUCT LINER. ALL EXPOSED DUCTWORK SHALL SUSPENDED STRAIGHT AND LEVEL. FINAL PAINTING SHALL BE BY OTHERS. 4. BALANCING DAMPERS SHALL BE PROVIDED WHERE INDICATED FOR BALANCING OF SUPPLY AIR IN THE SPACE. 5. ALL ROUND RUN -OUTS SHALL BE MADE WITH SPIN -IN FITTINGS WITH SCOOP AND ADJUSTABLE DAMPER WITH LOCK NUT. WHERE MORE THAN ONE DIFFUSER IS SERVED FROM A SINGLE RUN -OUT, DIFFUSERS SHALL BE EQUIPPED WITH BALANCING DAMPERS IN THE THROAT OF SUCH DEVICES. 6. MAXIMUM LENGTH OF FLEXIBLE DUCTWORK IS 5'-0" 7. AIR DISTRIBUTION DEVICES SHALL BE ALL SELECTED FROM THE SAME MANUFACTURER AND SHALL BE PROPERLY SELECTED FOR CEILING OR WALL FINISH. COORDINATE FINISHES WITH ARCHITECTURAL DRAWINGS. PRIOR TO INSTALLING FACE PLATES, SPRAY PAINT ALL PARTS VISIBLE THRU THE FACE FLAT BLACK. CONTRACTOR SHALL COORDINATE EXACT CEILING DIFFUSER PLACEMENT WITH LIGHTING FIXTURES AND SPRINKLER HEADS AND SHALL MAKE ADJUSTMENTS AS NECESSARY. REFER TO ARCHITECTURAL CEILING PLAN AS NECESSARY. HVAC EQUIPMENT: 1. EXISTING AIRPORT SUPPLY AIR AND VAV UNITS BY THE ORLANDO SANFORD AIRPORT AUTHORITY UNLESS DIRECTED OTHERWISE. EXECUTION: 1. CONTRACTOR SHALL EXECUTE HIS WORK AS FAST AS THE JOB SCHEDULE PERMITS WITHOUT DISRUPTING THE WORK OF OTHER TRADES. COORDINATE CONTROL AND POWER WIRING WITH DIVISION 16. 2. ALL WORK SHALL BE WARRANTED FOR A PERIOD OF ONE YEAR WITH AN ADDITIONAL 4 YEAR WARRANTY ON THE AIR CONDITIONING UNIT COMPRESSOR(S) MANUFACTURER. MECHANICAL RENOVATION NOTES: 1. VISIT THE SITE AND CAREFULLY EXAMINE THE EXISTING CONDITIONS BEFORE SUBMITTING BIDS, AS NO ALLOWANCE WILL BE MADE FOR LACK OF KNOWLEDGE OF EXISTING CONDITIONS WHERE SUCH CONDITIONS MAY REASONABLY BE DETERMINED BY OBSERVATION. 2. THE EXISTING INSTALLATION IS TO REMAIN IN PLACE AND IN SERVICE EXCEPT AS OTHERWISE INDICATED OR SPECIFIED. ALL WORK NECESSARY .FO'PROPERLY TIE IN THE NEW WORK WITH THE EXISTING WORK AND ADAPT THE EXISTING INSTALLATION TO THE CHANGES IN THE BUILDING AND IN THE SYSTEMS SHALL BE PERFORMED. 3. EXPOSED DUCTWORK, PIPING AND CONTROLS RENDERED USELESS DUE TO CHANGES IN THE BUILDING SHALL BE REMOVED AS NOTED. 4. CONCEALED DUCTWORK, PIPING AND CONTROLS EXPOSED BY THE REMOVAL OF WALLS, PARTITIONS, ETC., SHALL BE REMOVED OR RECONNECTED AS REQUIRED. i 5. ALL EXISTING DIFFUSER DROPS TO BE REMOVED BACK TO TRUNK DUCT, CAPPED AND SEALED. CONTRACTOR SHALL PROVIDE NEW FLEXIABLE DUCT AND NEW TAP WITH VOLUME DAMPER AS INDICATED. 6. ALL EQUIPMENT WHICH IS TO REMAIN IN SERVICE, BUT TEMPORARILY DISCONNECTED DUE TO THE ALTERATIONS TO THE BUILDING OR SYSTEMS, SHALL BE RECONNECTED AND RESTORED TO ITS ORIGINAL OPERATING CONDITION. 7. THE SIZE AND LOCATION OF EXISTING EQUIPMENT AND DUCTWORK SHOWN ON THE DRAWINGS SHALL BE VERIFIED AT THE SITE. 8. EXISTING MATERIAL THAT IS REMOVED AND NOT REUSED SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE PREMISES. 9. WHERE EXISTING INSULATION IS DAMAGED DUE TO NEW WORK, IT SHALL BE REPAIRED TO MATCH THE EXISTING INSULATION TO THE DAMAGED PORTION REPLACED WITH INSULATION OF THE TYPE SPECIFIED FOR THE NEW WORK. 10. SPRINKLER HEADS ARE EXISTING. CONTRACTOR SHALL RELOCATE HEADS AS REQUIRED TO MEET THE NEW ARCHITECTURAL LAYOUT AND CEILING HEIGHTS. ALL NEW SPRINKLER HEADS AND PIPING SHALL BE INACCORDANCE WITH THE LOCAL FIRE MARSHALL, CODES AND PER THE LANDLORD INSURANCE UNDERWRITERS. CONTRACTOR SHALL SUBMIT DRAWINGS AS REQUIRED TO THE FIRE MARSHALL FOR APPROVAL. 11. ALL EXISTING SUPPLY AND RETURN DIFFUSERS TO BE REMOVED. HANGER SUPPORTS: 45 DEG TAKE- OFF FITTING: WITH VOLUME ....................................... DAMPER SIZES SHOWN ARE FREE AREA MINIMUM RADIUS EQUAL TO THE FLEX DUCT DIAMETER SADDLE 2" HANGER STRAP (TYPICAL) SHEET METAL FOR RUN -OUTS GREATER THAN 6', WITH INSULATION @ R=8.0 EXISTING VAV BOX SCHEDULE MARK M ETALU NA CFM MAX. KW VOLTS/PHASE UNIT TYPE MANUFACTURER Architec rJ I- e •' t e & DesiEn LC. --- 1200 1665 Highway a 88 120V, 1 PH. VFREM Ellisville MIS 39437 \. ................ .. ��o�< ................: .::..::::..:...:..: . . TEL 601.91 ,1,6909 F FAX I . X �0 763.4886 .\\ ._ ,. Of - : B 24 1 2 ...:..:. P CA F T -F/ -..l . f.. \/\(,Nvv.METALUNAarchitects.com LTL- IF F f +] I t + iF_ metal emsuna mindsP rin 1- ;i ! %: .coal II III HANGER SUPPORTS: 45 DEG TAKE- OFF FITTING: WITH VOLUME ....................................... DAMPER SIZES SHOWN ARE FREE AREA MINIMUM RADIUS EQUAL TO THE FLEX DUCT DIAMETER SADDLE 2" HANGER STRAP (TYPICAL) SHEET METAL FOR RUN -OUTS GREATER THAN 6', WITH INSULATION @ R=8.0 EXISTING VAV BOX SCHEDULE MARK CFM MIN. CFM MAX. KW VOLTS/PHASE UNIT TYPE MANUFACTURER VAV-1 --- 1200 2 120V, 1 PH. VFREM ENVIRO-TEC NOTES: 1. CONTRACTOR SHALL FIELD VERIFY CAPACITY OF VAV AND REUSE AS INDICATED. FLEXIBLE DUCT: INSULATED, MAXIMUM 5' LONG, DO NOT SAG OR KINK SEAL INSULATION OR DUCT CONNECTION A- TO DIFFUSER TO FORE SEAL AT DUCT CONN[ CEILING DIFFUSER NOTE: 1 . HANGER SUPPORTS SHALL BE PER SMACNA AND APPLICABLE SPECIFICATIONS. 2. ELBOWS SHALL BE SQUARE NECK (SAME IN AND OUT DIMENSION) WITH 2" DOUBLE THICKNESS TURNING VANES. 3. OFFSETS SHALL NOT EXCEED 30" ANGLE, AND SHALL NOT REDUCE THE FREE AREA OF THE DUCT. 4. TRANSITIONS SHALL NOT EXCEED 1:3 RATIO (4" TRANSITION PER FOOT SINGLE SIDED TRANSITION, AND 8" PER FOOT DOUBLE SIDED TRANSITION). 5. RECTANGULAR BRANCH CONNECTIONS SHALL BE 45° ENTRY TYPE, WITH METAL SLEEVE AND CLINCH LOCK CONNECTION. ENTRY LENGTH SHALL BE 25% OF BRANCH DUCT WIDTH. 6. ROUND BRANCH DUCT CONNECTIONS SHALL BE SPIN -IN FITTINGS, WITH EXTRACTOR, DAMPER AND HANDLE. 7. FLEXIBLE ROUND DUCT SHALL INCLUDE: TRIPLE LOCK METAL FLEXIBLE DUCTING, BLANKET INSULATION AT A MINIMUM 8.0 R VALUE, AN ALUMINUM FOIL OUTER VAPOR BARRIER, AND BE UL -181 APPROVED. DIFFUSER CONNECTION DETAIL NOT TO SCALE THIS DRAWING AS AN INSTRUMENT F SERVICE, I L O C S AND SIAL REMAIN rHE PROPERTY OF ARCHITECT. USE OF THE DRAWING, OR ANY REPRODUCTION THE RE OF WITHOUT THE EXPRESS R SS WRITTEN PERMISSION OF THE DESIGNER IS STRICTLY PROHIBITED. SUBMISSION OR DISTRIBUTION TO MEET OFFICIAL REGULATORY REQUIREMENTS OR FOR ANY OTHER PURPOSES IN CONJUNCTION WITH THIS PROJECT IS NOT TO BE CONSTRUED AS PUBLICATION IN DEROGATION OF THIS ARCHITECTS RIGHTS. COPYRIGHT 2008 NO. DATE REVISION 1 2-22-09 _ OWNER REVISION HVAC SYMBOLS AND ABBREVIATIONS ---® EXISTING DUCTWORK VAV-* VARIABLE AIR VOLUME A NEW DUCTWORK CFM CUBIC FEET PER MINUTE B RETURN FLEXIBLE DUCT 0- DIFFUSER DESIGNATION VOLUME DAMPER 21 RETURN OR EXHAUST GRILLE ® SUPPLY DIFFUSER Of THERMOSTAT DIFFUSER SCHEDULE MARK /n\ NECK �l 150 CFM MARK TYPE FACE BASIS OF DESIGN A SUPPLY 24 x 24 TITUS OMNI -AA B RETURN 24 x 12 TITUS 50F 1. DIFFUSER FRAME TYPES SHALL BE COMPATIBLE WITH ARCHI- TECTURAL CEILING TYPES IN WHICH IT IS INSTALLED. 2. ALL TO BE OFF-WHITE FINISH, UNLESS NOTED OTHERWISE. `I i 'z� LANDLOKIYE) EXI51ING 51,161"FNPEP CEILING III 1111 I° I B 24 1 2 II � III F T -F/ -..l LTL- IF f +] I t + iF_ II 1- ;i ! %: I I + II III I II IIII II' III • TO A\/ -I r Irm I r r-r� 8 �T r� / r T r 1 � 1- II IIII II F} 1 AD + 1 / I I -I -i I {+ I {+{ 1 -I-+ 1 15++ LL_L / , 4-+-I LL_LJ ® h_ -+-1 LL_lJ 4 +-IIL11J LL1J TLI I III IIII III II / 8'0 A 12 24-XI -� R -- II IIII // / 15 II j L IL TO VAV 1 I I // . ® , / I + f "t- -f i I t ....';y • -I- -+ I I- I- I I LLJ J LL_LJ LLLJ �LsJ r Ir- I I II III 8 0 (' II I II III A 15 0 / �II!!II� I r TT / I -TT -1 r -7T-1 f T -T-1 r -TT -1 III IIII I -i - / I- 1 -1- { F +- -i- -{ I- J_ -I F -i - + -1 III IIII 11 I- l.r nl I F + I- -I- + -i I I + I- "I- + -1 L �':>JassJ / L1 -LJ LLJ-J LL_LJ LL_LJ A TO VAV-11 IIII III • 8"0 61:10I A (� I II I II IIII II / / 15010 TO AV -1 I II -If II III / / r_ T- -r -1 r- 7 -r -1 r- T- -r -1 F T- r -1 II III II / / F + -I -I I + -+ 1 F +- 1 -1 I -1- -i -I L IL Jill1 f I + -1 • I -}- -1 - { -1-- + -1 I I + 1 • // L _L -i ILL_LJ LL1J LL_L_J (� _JIT L- ELOCA ED T'ST6,T I f r -----ter---, Il T -III ^ I - 24x I I I- T- T -1 f T T -1 f T T -1 r- _F r> IF �I J i 1+ 1 I f -i I i -i- 1 + i B 12 --- - - ^' - - - = I F + -I { -1- + -I I -1- + -1 I-`Frl --- I LL_LJ LL_LJ LL_1J uL%L'J F- 2 IxI2 I I III B i II r TT 1 r I --r r T T r rTVAV- F_T 1 rTT 1 I + + i F +- I- 1 -1- 1 F +- + -1 i + i 1- t- -1- -1 L_y r - ` I I- + + -1 I- -(fid`=1 I- +- + -I I- +- + -I -1+- -I -I- + -I I LL1J LL> >J LL_L-1 LL1J LL1J LLJ J 6110 AJ6"10TO V V-1 TO V -1 I- I f T -r -I F_ T-1 I -TT -1 1- I TT -1 F_ L -_ { i- -} _{ I- +- + 1 I i- + _ { I- -I-- -1--1 F_ -t-- -1- { I + + -1 F nil- II I 4- 4 -1 • I- 4- + I 4- + -1 • I- +- + -I I- "I- -1- -1 +- + -1 • 1 1 LL_LJ LL_1J LL- J LL1J L1_ -.J L_LLJ F_ II I I I III 1 - L_� r--r-r-1 r - T -T/ r--r-r-I �T-T-1 r -TT -1 r - TT/, 1 r- I I h I t i F f 1 F F t I I- t 1 i i+ 1 -1 f -f t. 14-+ I I-1+ 1 LL_LJ o""'W'J LL1J LLLJ LL_LJ Irl[ 1 I_ 1 11. 8" TO VA -1 200 A 00 III TO V+_ I F T-1 r- F- T- -T -1 l -TT 1 f T -T-1 r'T-r-1 F - I f i + 1 + + -1 F t -i- -1 F +- -I- -I + + f- -f- -t 14- + -1 I 1 + -1 I -I- + -1 • I +- + I- I- + 14- + • LL_LJ LLLJ LL_LJ LL_L-1 LL_LJ LL1J ��I B 24x 2 VI i --- - 1 i --- -- i ilk_ II II I� 1II _-_ SII ---II SPRINKLER HEAD, TYPICAL. _ REFERENCE APPROVED ° SPRINKLER CONTRACTOR LAYOUT FOR FINAL HEAD LOCATION. ADJACENT RESTAURANT MECHANICAL (PLAN 1/4!1=1101' '^... ._ NOTES TO CONTRACTOR: 1 1. INFORMATION AS SHOWN OR INDICATED ON THE DRAWINGS WAS DONE FROM INFORMATION RECEIVED FROM THE JOBSITE THEREFORE THE CON- TRACTOR SHALL VISIT THE JOBSITE PRIOR TO BIDDING TO DETERMINE THE EXTENT AND SCOPE OF HIS WORK. 2. THE EXISTING VAV BOX AND DUCTWORK FOR VAV-1 SHALL BE REUSED. 3. CONTRACTOR SHALL CONNECT NEW DUCTWORK FOR THE DIFFUSERS TO THE EXISTING DUCTWORK FOR VAV-1 BOX AS REQUIRED. 4. A TEST AND BALANCE OF THE' SYSTEM SHALL BE PREFORMED BY AN INDEPENDANT T AND B COMPANY AND A CERTIFIED REPORT SHALL BE GIVEN TO THE TENANT AND AIRPORT WHEN FINISHED. S. CFM AS SHOWN AT EACH SUPPLY DIFFUSER SHALL BE VERIFIED AND COORDINATED WITH THE MAXIMUM CFM BEING DELIEVERED FORM VAV-1. 6. CFM RATING OF THE VAV BOX FROM THE FIELD WAS 1200 CFM, BUT COULD NOT BE VERIFIED. CONTRACTOR SHALL FIELD VERIFY CAPACITY OF VAV BOX #1 AND REPORT HIS FINDINGS TO THE ARCHITECT AS SOON AS POSSIBLE IN WRITING. Hudson News - Hudson Booksellers Papyrus RENOVATIONS AND ALTERATIONS TO EXISTING RETAIL SPACE IN TERMINAL A -INTERNATIONAL DEPARTURES- UPPER LEVEL ORLANDO SAN FORD 0 T C� R INTERNATIONAL NAL AI RP S ANFO RD FLORIDA NOTE- TO CONTRACTOR: WHEN THE CONTRACTOR OBSERVES ERRORS, DISCREPANCIES, OMISSIONS OR AMBIGUTIES IN THE CONTRACT DOCUMENTS, CONTRACTOR SHALL IMMEDIATLEY, IN WRITING, REFER SAME TO THE ARCH- ITECT FOR THE ARCHITECT'S WRITTEN INTERPRETATION OR CORRECTION. IF CONTRACTOR SHALL FAIL TO GIVE NOTICE OF SUCH WORK BEFORE CONSTRUCTION OR FABRICATION OF THE WORK, CONTRACTOR WILL BE HELD RESPONSIBLE FUR THE RESULT OF SUCH ERROR, DISCREPANCY OR OMISSION. DON PENN, P.E. FLORIDA ENG ME''INFER N0. 0051096 (,H d635 WESTPO RT PARKWAY SUITE 300 p G ' 7 GRAPEVINE, TEXAS 76051 817-410-2858 FAX 817-251-8411 DRAWN .JVP CHECKED DP DATE JOB NUMBER 08 14.