Loading...
109 Red Cedar Dr - BR08-000717 (REPLACE GARAGE DOOR) DOCUMENTSApplication #: 00 / Job Address: 10a?G ' Parcel ID' Description of Work: G t CITY OF SANFORD PERMIT APPLICATION "V1, + /' ll _ l 6 Submittal Date: ( Value of Work: $ '7 Oo ° Zoning: a C) Historic District: Square Footage: Permit Type: Building G( Electrical • • • • Mechanical • • • • • •Plumbing Fire Sprinkler/Alarm Pool Q Sign Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential `- New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # ,of Water Closets Plumbing Repair —Residential Commercial Occupancy Type: Residential Commercial Industrial Occupancy Use Group(s): t/ of Stories: # of Dwelling Units: Flood Zone: (EEMA form required) Construction Type: ... 4 .................................... c' p Contractor: i Property Owner: g t' d (/ I C Address: Address: c' e G 7 jj+*i% Pon t State License Numbercpc 6603 y r% 72 E-mail: Phbne Bonding Company: Mortgage Lender. Address: Address: Arch itect/Engineer: Phone: Fax: Address: Plan Review Contact Person: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuanceofapermitandthatallworkwillbeperformedtomeetstandardsofalllawsregulatingconstructioninthisjurisdiction. 1 understand that a separate permitmustbesecuredforELECTRICALWORK, PLUMBING, SIGNS; WELLS, POOLS, FURNACES, BOILERS; HEATERS; TANKS, and AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating constructionandzoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICEFORIMPROVEMENTSTOYOURPROPERTY. IF YOU INTEND TO OBTAIN FINANCING; CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of thiscounty, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies, Acceptance of permit is verification that I will notify the owner of the property of the regi Signature of Owner/Agent Date Print Owner/Agent's Name Signature of Notary -State of Florida Date Owner/ Agent is _ Personally Known to Me or Produced lD APPROVALS: ZONING: U I IL: FD. Special Conditions: Rev 02/2007 Contractor/ Agent is Produced ID Me or V T 1 VALUATION ENTITY Gary Pfuehler; P. E. 5665 Green Oak Court Fairfield, OH 45014 1 Product ESA' uation Report for Florida DCA . Evaluation Report # 4300W4-09 MANUFACTURER Clopay Building Products Company 8585 Duke Blvd. Mason, OH 45040 513.770.4800 The Clopay Building Products Company sectional doors as described on the drawings listed below meet the design and test pressures shown. Based on the testing and rational analysis detailed below, this product is evaluated to be in compliance with the following provisions of the Florida Building Code: Outside the HVHZ: Wind Loads (tested in compliance with FBC 1714.5.3.1, ref. ANSI/DASMA 108 or TAS 202) Inside the HVHZ: Wind Loads for HVHZ (tested in compliance with FBC 1714.5.3.1, ref. TAS 202), 1625 Cyclic Tests for HVHZ (ref. TAS 203), 1626 Impact Tests for HVHZ (ref. TAS 201) Double -skin Insulated (exterior skin 27 ga. min,, interior skin 27 ga. min.) Description of Product: Single -Car (up to 9'0" wide) WINDCODE® W4 Garage Door Design Pressures: +28/-29 Test Pressures: +42/43.5 Specific Models and Technical Documentation: UnAe! Test Report Drawing No. Comments 4400W4, 4401 W4, Glazing approved per HCN-5A, HCN-5. Low head room track approvedHDGW4, HDGLW4, 4300W4, 4310W4, HCN-21 101652-Revo5 per HCN-126. 4301 W4 Glazing approved per HCN-5A, HCN-5. Low head room track approvedSP20W4, SE20W4, HCN-21 101652-Rev05 er HCN-126. SF20W4 Glazing approved per HCN-5A, HCN-5. Low head room track approved 66W4, 67W4, 68W4 HCN-21 102049-Rev03 per HCN-126. H400W4, H401 W4, Model uses horizontal reinforcement; door height does not effect H310W4, H300W4, HCN-21 102488-RevO2 performance. H301 W4 Installation requirements: Installation must be in accordance with manufacturer's installation instructions. Limitations and conditions of use: Jambs, lintels, sills or other structural,elements required to prepare openings are not covered. The design of the supporting structural elements shall be the responsibility of the professional of record for the building or structure and in accordance with current building codes for the loads listed on the drawing(s) referenced above. Certification of Independence of Evaluation Entity: I hereby certify that (1) I have no financial interest in Clopay Building Products. Company; (2) I am an independent licensed Professional Engineer in the State of Florida; and (3) I comply with the criteria of independence as stated in 913772.110 F.A.C. Signature:-, 1r, P. E. Gary Pfu e Florida P. E. No. 49850 Date: l lis J FILE:4300W4-09-REv02 GPI ORHOLUQ PHRIGDUC APPFUR o MALE 3026HU 03 CLOPAY MODELS 4400, 4401 (24 GA. EXTERIOR SKIN) CLOPAY MODELS HDG. HDGL. 4300. 4301, 4310 (27 GA. EXTERIOR SKIN) IDEAL MODELS SP20. SE20. SF20 (27 GA. EXTERIOR SKIN) OPTIONAL WINDOW UTE DSB GLASS OR 1/8' ACRYLIC AVAILABLE. OPTIONAL ARCYUC GLAZING IS PLASKOUTE OPTIX OR LUCRE CP APPROVED CC2 PLASTIC IN ACCORDANCE WITH IBC/FBC2606 (SEE IN B—B) _ I 1 I I I I I r / I L______JBI 1L______J LI rQa zu I' ---:pI I----1 III III III II 111 I11 III S II lit L' ___iJ ill OPTIONAL OUTSIDE KEYED — A LOCK POSITION MAX. DOOR WIDTH - 9•-0- INSIDE ELEVATION SEE END HINGE DETAIL SEE INTERNED. HINGE DETAIL TWO POINT LOCKING INTO TRACK 4) /14x5/8' SHEET METAL SCREWS O 4) 1/4•x3/4• SELF TAPPING SCREWS 14 GA. ENO HINGE 19 GA. INTERAIEDNTE HINGE NOTE: 14 GA. INTERMEDIATE HINGES ON 24 GA EXTERIOR SKIN DOOR MODELS.) HORIZONTAL TRACK SUPPORT BY DOOR INSTALLER (TO SUIT)- I ICI - I 1 ICI ill ICI ICI III ICI oo.VV1.1 rI L______J 1r— ----- TTf------ lr/ / IIIIIIIF/ I III I L______J L______9 YK r--- _T= r=__= T r _ _ T i I11 III III III III III III III IL _I 1_ K J L___ IT - - - - Ijl ICI ICI Nil III ICI ICI ICI r =____ T r _ = T11 III Ill Ill Ill Ill III Ill 111 1L OPTIONAL OUTSIDE KEYED A LOCK POSITION MAx. DooR YnorH FRONT FRAME WITH U.V. COATING ON OUTSIDE SURFACE. n n 11 II II II GLAZING MOLDED INSIDE SECTION B—B / 80-1/4' PAN UTE RETAINER. OPTIONAL 10 SCREW WINDOW LITE HEAD SCREW. 10 SCREWS PER LITE) 13 CA GALV. STEEL FLAG BRACKET. EACH FASTENED TO WOOD JAMB WITH 3) 5/16•xl-5/8' WOOD LAG SCREW.. - TRACK CONFIGURATION LHR.TOP BRACKET DOUBLE HORIZONTAL 2x6 YELLOW PINE JAMB S2 WM DOUBLE TRACK TRACK 12 GA GALV. STEEL TRACK i LOW HEADROOM IS BRACKET FASTENED T WOOD AVAILABLE AS AN OPTION JAMB WITH ONE 5/16•xl-5/8' WOOD LAG SCREW PER BRACKET. 2' GILI. EL' GALV. STEEL TRACK Y TRACK THICKNESST::.O60' DOUBLE TRACK FASTENED2 TO TRACK BRACKETS LOW HEADROOM OPTION EACH BRACKET ATTACHED WITH ONEl' 1/4•x5/8' BOLT a, NUT DE TWO 1/4• RIVETS. s u JAMB CONFIOURATION TYP. 2-1/2'x12 CA GALV. STEEL TRACK BRACKET. 4) TRACK BRACKET PER SIDE. DISTANCE BETWEEN SECTION C—C 0 1PACK BRCKETS NOT T EXCEED 30. O.C. (FACTORY ATTACHED) SNAP LATCH ENGAGES ONTO VERTICAL TRACK. ONE SNAP LATCH - EACH SIDE OF DOOR. OUTSIDE KEYED V.D HANDLE mLE INSIDE HANDLE OU1510E KEYED LOCK SNAP LATCH LOCH OPTION VERTICAL JAMB ATTACHMENT (C-90 BLOCK OR 20DO PSI MIN. CONCRETE COLUMNI: 3/8'X4' SLEEVE ANCHORS ON 24' CENTERS BOTH C-90 BLOCK OR 2000 PSI MIN. CONCRETE) OR 1/4'X4' TAPCON SCREWS ON 24• CENTERS (2000 PSI MIN. CONCRETE). WASHERS INCLUDED WITH SLEEVE ANCHORS, 1' O.D. WASHERS TWO POINT LOCKING REWIRED WITH TAPCONS. ANCHORS MAY INTO TRACK BE COUNTERSUNK (BUT NOT REQUIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. VERTICAL JAMB ATTACHMENT (WOOD FRAME BUILINGSI: 1/2'x3' LAG SCREWS ON 24' CENTERS. 1' O.D. WASHER REWIRED. LAG SCREWS MAY BE COUNTERSUNK (BUT NOT REWIRED) TO PROVIDE A FLUSH MOUNTING SURFACE. HORIZONTAL JAMBS DO NOT TRANSFER LOAD. 27 GA. MIN. STEEL EXTERIOR SKIN WITH G-40 GALVANIZING. BAKED —ON PRIMER AND A BAKED —ON POLYESTER PAINTED TOP COAT. a a 2' THICK SILICONE FILLED CHANNEL SEPARATES FRONT AND BACK SKIN OF DDOR 1.95' THICK. 1i DENSITY EXPANDED POLYSTYRENE FOAM INSULATION 1M11NATED TO BOTH EXTERIOR AND INTERIOR SKINS. 12 GA GALV. STEEL TOP ROLLER BRACKET. EACH BRACKET ATTACHED W/(3) 14x5/8' SHEET METAL SCREWS. TONGUE AND GROOVE JOINTS. 2-1/4• TALL x 20 GA. GALV. STEEL U—BAR. THREE PER DOOR. ATTACHED WITH (2) 1/4'x3/4• SELF TAPPING SCREWS AT EACH HINGE LOCATION.. SECTION A —A 27 GA. STEEL INTERIOR SKIN WITH G-60 GALVANIZING. BAKED —ON PRIMER AND A BAKED —ON POLYESTER PAINTED TOP COAT 13 GA CALV. STEEL BOTTOM BRACKET. ATrACNEO WITH (4) /14x5/8' SHEET METAL SCREWS. ALUMINUM EXTRUSION SUDE BOLT SCALE 2' I' h VINYL WEATHERSTRIP. END LOCI( ENGAGES STILEINTO VERTICAL TRACK. ONE END LOCK ON STILE EACH SIDE OF DOOR. INSIDE SLIDE BOLT LOCK OPTION THIS DOOR MEETS OR EXCEEDS THE DESIGN OUTSIDE LOADS FOR THE WIND SPEEDS LISTED BELOW HANDLE ACCORDING TO THE FLORIDA BLDG. CODE OR IBC (ASCE7) FOR THE FOLLOWING LOCK CONDITIONS: 1) ENCLOSED BUILDING, 2) DOOR ENGAGES STOP MOULDING BY DOOR HAS 2 OF WIDTH IN BUILDINGS END ZONE, TRACK ON INSTALLER (To SUIT) 3) IMPORTANCE FACTOR OF 1.0, 4) ANY OUTSIDE KEYED LOCK EACH SIDE 18 GA. GALV. STEEL END STILE END STILES HELD BY HINGE SCREWS) ROOF SLOPE AND 5 5076 SAFETY FACTOR. .K R L _KIN. OF DOOR. WIND SPEED MPH S 1 OO 110 110 120 EXPOSURE LI B or C B I C 1 8 MEAN ROOF HEIGHT 30• 1 30' 1 24'1 30• THE OPTIONAL GLAZING SHOWN ON THIS DRAWING MEETS THE 18 GA. MIN. GALV. STEEL CENTER HINGE WIND LOAD REQUIREMENTS OF THE FLORIDA BUILDING CODE FASTENED TO INSIDE SKIN W/(4) OR INTERNATIONAL BUILDING CODE BUT DOES b0T MEET THE EACH /14x5/8' SHEET METAL SCREWS. IMPACT RESISTANT REQUIREMENT FOR WINDBORNE DEBRIS 14 GA GALV. STEEL. ROLLER HINGE REGIONS REF. CHAPTE:R16 FBC IBC FASTENED T END STILES W/(4) EACH DESIGN ENGINEER: MARK WESTERFIELD, P.E. 14x5/8• SHEET MErAL SCREWS FLORIDA P.E. #48495, NC P.E. 023832, TEXAS P.E. /91513 2' STEEL ROLLER. PREPARATION OF JAMBS BY OTHERS, MM THE DESIGN OF THE SUPPORTING STRUCTURAL ELEMENTS SHALL BE THE RESPONSIBILITY OF THE PROFESSIONAL OF RECORD FOR THE BUILDING OR STRUCTURE AND IN ACCORDANCE TIH CURRENT BUILDING CODES FOR THE LOADS LISTED ON THIS DRAWING. DESIGN LOADS: +28.0 P.S.F. h —29.0 P.S.F. TEST LOADS: +42.0 P.S.F. k —43.5 P.S.F.