Loading...
183 Walnut Crest Run - BR08-000058 (PORCH WINDOW) DOCUMENTSQ CITY OF SANFORb PERMIT APPLICATION Application #: S(, Submittal Date: v' i Job Address: ) G Vahlot Cre, f ,uh + Value of Work: S , Q ` u Parcel ID: ZZ' 1 I ' t Uf ^y (,UU u" (Z5Q Zoning: j Historic District: Description of Work: AdaL Pu ` oddty# / 000 9A Square Footage: Permit Type: Building f Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service - # of AMPS Addition/Alteration Change of Service Temporary Pole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair - Residential Commercial Occupancy Type: Residential e Commercial Industrial Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required Property Owwner: / l l c h g a l f Re4ec c q lloy 6e V Contractor: C Q I ti i Yd Pfj COY 0`/ ` Address: I 3 walho c e i Rb t) Address: 2-3w -wq t i We FL. 32-7)1 Ley wood FL 275 2 _ Phone: I) I 3 2'rJ E-mail: Phone b 2ZState License Number: CI , J Z G% 7 Bonding Company: Address: Architect/ Engineer: Address: Plan Review Contact Person Mortgage Lender: Address: Phone: Fax: Phone: Fax: E-mail: Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. [ understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE- THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records oi' this county, and there may be additional permits required from other governmental entities such as water management districts, s to agencies, or federal agencies. cceptance of permit is ve ' cation that I will notify the owner of the property ofthe mnt o Lien Law, FS 13. Signat1ire o Owner/Agent Date Sigril.Cure ofContractor/Agent Date itcc_ af er- tl k-ler I P nt O er/A n 's Name P t Contractor/Agent's ame 0, 6 Datd Signature of Notary -State of Flori a Date HANNE RE C. ELVESTER Notary Public - State of Florida Commission Expires Aug 16, 2009 Commission # DD 462522 Produced ID - APPROVALS: ZONING: •O UT11L: FD: p X \ O1 SecialConditions: &ctnC Rev 07.07 Sarah H Staphana commission peCFt l008 Contractor/Ag9erronalyVtovt Produced ID ENG:, BAG:_ 9- 72" MAX UNIT FiT I1 68 MA I SA HT C MAX( UNI I WIU I H 11_7/8" ACRYLIC I LO I 63 15/16" ACRYLIC DLOI I;; 7 Fl1/16" 44 1/4" ACRYLIC DLO 95" r MAX = SASH HT 96': 190 114" MAX ACRYLIC UNIT DLO HT 5200 OUTSIDE MOUNT W/REMOVABLESCREEN 96" MAX UNIT WIDTH 52XO MULTIPANEL SLIDER 2P2T OR 2P3T TABLE OF CONTENTS GENERAL NOTES & ELEVATIONS .................. A ANCHOR SCHEDULE & NOTES . ................2 SECTION VIEWS(5200).....................................3 SECTION VIEWS(52X0).....................................4 B.O.M: S..............................................................5 EXTRUSIONS(5200)..........................................6 EXTRUSIONS(52XO)..........................................7 INSTALLATION DETAIL .... :......................... 8-10 78" MAX UNIT WIDTH ACRYLIC SLIDER WNDBREAKER" REQUIREMENT 3/4" MAX. PANEL I j'-- -- 38 3/4" MAX. PANEL 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TOWIDTH 34 7/8" ACRYLIC = -- WIDTH COMPLY WITH THE FLORIDA BUILDING CODE DLO g_ F .. .____.... MAX 87 15116" UNIT ACRYLIC HEIGHT DLO 92 1/8" MAX PANEL HEIGHT 5200INSIDE MOUNT & OUTSIDE MOUNT W/ SPLINE GROOVE 48 1/8" MAX PANEL WIDTH h PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINOOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM VNANDOW SYSTEMS. INC. IS PROHIBITED. PERM# _ D S61 DATE; 2. GLAZING OPTIONS: FULL PANEL ACRYLIC SHEET SPLIT ACRYLIC SHEET WITH USE OF CENTERBAR 3. APPROVED CONFIGURATIONS: X/X" ISM W/ SPLINE GROOVE X/X" OSM W/ SPLINE GROOVE X/X" OSM W/ REMOVABLE SCREEN X/X" INTERIOR SGD FRAME MULTIPANEL X/X" EXTERIOR SGD FRAME MULTIPANEL X/X" W/ SCREEN INTERIOR SGD FRAME MULTIPANEL X/X' W/ SCREEN EXTERIOR SGD FRAME MULTIPANEL X/X/X/X INTERIOR SGD FRAME MULTIPANEL X/X/X/X" EXTERIOR SGD FRAME MULTIPANEL X/X/X/X' W/ SCREEN INTERIOR SGD FRAME MULTIPANEL X/X/X/X" W/ SCREEN EXTERIOR SGD FRAME MULTIPANEL 4. WINDBREAKER REQUIREMENT: VENTS TO BE REMOVED AT WINDS GREATER THAN 75 M.P.H. AS PER SECTION 2002.3 OF THE FLORIDA BUILDING CODE. 5. ANCHORAGE: THE 33 1/3% STRESS INCREASE HAS NOT BEEN USED IN THE DESIGN OF THIS PRODUCT. SEE SHEETS 9-11 FOR ANCHOR DETAIL. 6. ALL FRAMES AND VENTS SCREWED TOGETHER 7. PREFERENCE TEST REPORT. CTLA-1162W 8. SERIES / MODEL DESIGNATIONS - ISM/OSM - HS-5200 MULTIPANEL - HS-52XO 9. WOOD BUCK OR STUD FRAMING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. BUCK OR FRAMING IS RESPONSIBILITY OF ARCHITECT OR ENGINEER OF RECORD. 10. SECTION CALLOUTS APPLY TO ALL ELEVATIONS IN A SIMILAR LOCATION. 4a Y Oi9A e 6" MAX I _ - 18" MAX O.C. (TYP) 6" MAX 18" MAX O.C. (TYP)- 6 MAX I --SEE NOTE 3 6., MAX I INSTALLATION ANCHORS (TYP) MAX O.C. -- -_-- TYP) 18" MAX O.C. III (TYP) ANCHOR LAYOUT -52001SM/OSM 1 HRU NAILING PIN (ALUM. POPCH ENCLOSjRE SEE SHEEt 9) ANCHOR LAYOUT -52001SM/OSM THRLI NAILING FIN (WOOD) SEE SHEET 9) 6" MAX (T` 6" - MAX (TYP) 18" MAX O.C. TYP) INSTALLATION ANCHORS (TYP) ANCHOR LAYOUT - (FRAME) THRU FRAME TYP) SEE SHEET 10, NOTES: 1- INSTALL ONE ANCHOR AT EACH LOCATION, 2. INTO CONCRETE/MASONRY OR WOOD: SHIM AS REO'D AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS. MAX. ALLOWABLE SHIM STACK TO BE 114". USCSHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT. 3. INTO ALUMINUM: SHIM AS RED AT EACH SET OF INSTALLATION ANCHORS USING LOAD BEARING SHIMS, MAX. ALLOWABLE SHIM STACKTOBE1/8". USE SHIMS WHERE SPACE GREATER THAN 1116" IS PRESENT. 4. LOAD BEARING SHIMS SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. WOOD SHIMS ARE NOT ALLOWED. 5. 3/16" DIA. ELCO TAPCON (OR EQUIV.) MASONRY ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/4" INTO MASONRY THRU FRAME OR THRU 1 BY WOOD BUCK INTO MASONRY. A MINIMUM EDGE DISTANCE OF 2 1/2" SHALL BE ACHIEVED. 6. #10 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN, EMBEDMENT OF 1 1/2" INTO 2 BY WOOD BUCK. 7. #8 WOOD SCREW ANCHORS MUST BE OF SUFFICIENT LENGTH TO ACHIEVE A MIN. EMBEDMENT OF 1 1/2" INTO 2 BY WOOD BUCK FOR FININSTALLATION. 8. SEAL CORNERS WITH SMALL JOINT SEAM SEALANT. 9. ALL INSTALLATION ANCHORS MUST BE MADE OF A CORROSION RESISTANT MATERIAL OR COATING. 10. #8 X 3/4" SHEET METAL SCREW ANCHORS MUST BE USED WITH FULL THREAD ENGAGEMENT INTO ALUMINUM ENCLOSURES. 11. AN APPROVED MEMBRANE OR MATERIAL SHALL BE PLACED BETWEEN ALL DISSIMILAR METALS TO CONTROL GALVANIC CORROSION. PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM VANDO'W SYSTEMS. INC. 15 PROHIBITED, NOTE 2 INSTALLATION ANCHORS (TYP) EX' TYPICAL VERTICAL SECTION OSM JAMB 2 OSM SILL EXTERIOR TYPI CAL HORIZONTAL SECTION 31 OSM HEAD W/SPINE GROOVE OSM JAMB W/SPINE GROOVE OSM SILL W/ SPLINE GROOVE ALTERNATE FRAME MEMBERS PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS. INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM VANDOW SYSTEMS, INC. IS PROHIBITED. TYPICAL VERTICAL SECTION r r3 2 TRACK HEAD 2, 52 i 2I 2 TRACK JAMB / 2 TRACK EXT. SILL 2 TRACK INT. SILL 3 TRACK INT. SILL ALTERNATE FRAME MEMBERS PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING 13 THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM N/INDOW SYSTEMS. INC. IS PROHI9ITED. TYPICAL VERTICAL SECTION 111 DRAWINGIS'HESOLEPROPERTYOFCUSTOM WINDOWS YSTEMS. INC. ANY RE PR ODUC7'ION IN PART OR AS .A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS. INC. IS PROHIBITED, 5200 ISM / OSM B.O.M. 5200 MULTIPANEL B.O.M. ItcmN Die 4' Descri lion OUTERFRAME ASSEMBLY (TYP) i i 2.187 1. ISM HEAD ALUM 6063-T6 3.000 ................a r2 ; 2.937 1._._..._...... _...._._....._.... ISM SILL ALUM 6063-T6 2.625 OSM SILL ALUM 6063-T6 3.000. u 2.937 L - OSM SILL ALUM 6063-T6 2. OSM HEAD W/SPINE GROOVE ALUM 6063-T6 3.000 - 2.937 H uyu OSM SILL W/ SPLINE GROOVE ALUM 6063-T6 3.000 _--- - — 3.000 - _ _.-_ 3.000 I 1.911 j 1.911 1.911 j.... 1 1 ISM JAMB OSM JAMB OSM JAMB W/SPINE GROOVE ALUM 6063-T6 ALUM 6063-T6 ALUM 6063-T6 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THF. SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WI'IOLE WITHOUT THE YJP,.ITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. 13 PROHIBITED. 1.000 j 1.000 h- 2.250 1.121 LOCKSTILE INTERLOCK ALUM 6063-T6 ALUM 6063-T6 VENT ASSEMBLY (TYP) a 4 1.000 I-- 1.000 r-- i_ 2.750 r8i 1.805 BOTTOM RAIL CENTERBAR ALUM 6063-T6 - ALUM 6063-T6 1.000 I 1 .780 -.... 2.000 825 L 1 _...__... GLAZEBEAD TOP RAIL ALUM 6063-T6 ALUM 6063-T6 1900 SW 44TH AVE. OCALA, FLORIDA 34474 ACRYLIC HORIZ SLIDFRS I BAT I`' 1/31120081 7 OF 11 1 .0 00 2 TRACK HEAD ALUM 6063-T6 3.997 1.500 2 TRACK EXT. SILL ALUM 6063-T6 3) r_ 3,687 911 2TRACK JAMB ALUM 6063-T6 1. 0oo i.... r.T7 3 TRACK HEAD ALUM 5063-T6 jj 5. 683 1. 500 3 TRACK EXT. SILL ALUM 6063-T6 5. 371 911 3TRACKjAmB ALUM 6063-T6 3. 874 (2) J. 65 2 TRACK INT. SILL ALUM 6063-T6 PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. PANEL ASSEMBLY (TYP) 5. 562 4 5 3 TRACK INT. SILL ALUM 6063-T6 1. 000 MULTIPANEL INTERLOCK ALUM 6053-T6 r SCREEN ADAPTOR ALUM 6063-T6 ASTRAGAL ALUM 6063-T6 1900 SW 44TH AVE. OCALA, FLORIDA 34474 ACRYLIC HORIZ. SLIDERS F""" " BAT 1/31/20081 8 OF I I SCREEN ENCLOSURE MEMBERS BY OTHERS 1/8" MAX SHIM PERIMETER CAI BY OTHERS WINDOW FR HEAD (ISM) EXTERIOR WINDOW FR, SILL (ISM) PERIMETER C, BY OTHERS 1/8" MAX SHIM -- SCREEN ENCLOSURE -- MEMBERS BY OTHERS A`,VERTICAL SECTION 7.; IIJSIDE M 81NSTALLATION SCREW ANCHOR CAULK BETWEEN WINDOW - FLANGE & SCREEN ENCLOSURE IULK BETWEEN WINDOW ANGE & SCREEN ICLOSURE 8INSTALLATION SCREW ANCHOR INTERIOR 8 INSTALLATION SCREW ANCHOR K BETWEEN WINDOW JGE & SCREEN OSURE INSIDE MOUNT 5200 FRAME INTERIOR 1/8" MAX SHIM--1 1\..._. PERIMETER CAULK BY OTHERS Bl\_HORIZONTAL SECTION INSIDE MOUNT (ALUM) WINDOW FRAME SILL (OSM) 8INSTALLATION SCREW ANCHOR SCREEN ENCLOSURE MEMBERS BY OTHERS 1/8" MAXSHIM— r- PERIMETER CAULK - — BY OTHERS EXTERIOR — DE MOUNT I-' CAULK BETWEEN WINDOW RAME FLANGE & SCREEN 8INSTALLATION ENCLOSURE SCREW ANCHOR C)HORIZONTAL SECTION I\ 7 /OUTSIDE MOUNT (ALUM) tIMETER CAULK DTHERS 1/8" MAX SHIM SCREEN ENCLOSURE MEMBERS BY OTHERS r (ALTERNATE MOUNTING OPTION 1, 7" OUTSIDE MOUNT (ALUM) PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. 1900 SW 44TH AVE. OCALA, FLORIDA 34474 avv w n. I:S DR.""t4 "Y -E. RYL H R SLIDERS BAT 1/31/2008 I:iDEC SCALE: U.^:3. WO.' 5200152X0 NTS CWS-183 RE',.!F.TiER SHEET 9OF 11 2 BY BUCK -- BY OTHERS 1/8" MAX SHIM I I PERIMETER C BY OTHERS WINDOW I HEAD 0SN EXTERIOR WINDOW FRAME SILL (ISM) PERIMETER CAULK BY OTHERS 1/8" MAX SHIM - 1 2 BY BUCK BY OTHERS 8 INSTALLATION SCREW ANCHOR CAULK BETWEEN WINDOW-- . FRAME AND BUCK BY OTHERS INSIDE MOUNT 1/8" MAX SHIM I 5200 FRAME INTERIOR ILK BETWEEN WINDOW ME AND BUCK PERIMETER CAULK -- THERS I" I BY OTHERS 8 INSTALLATION 2 BY BUCK SCREW ANCHOR I i BY OTHERS 2 BY BUCK I BY OTHERS PERIMETER CAULK EXTERIOR BY OTHERS 1/8" MAX SHIM - L CAULK BETWEEN WIND OUTSIDE MOUNT --- FRAME AND BUCK 5200FRAME BY OTHERS E\HORIZONTAL SECTION 8 INSTALLATION 8 j INSIDE MOUNT (WOOD) II SCREW ANCHOR G6) RIZONTAL SECTIONI\ g 1 OUTSIDE MOUNT (WOOD) WINDOW FRAME --- SILL (OSM) PERIMETER CAULK BY OTHERS i INTERIOR 8 INSTALLATION----- SCREW ANCHOR 1/8" MAX SHIM CAULK BETWEEN WINDOW ' FRAME AND BUCK BY OTHERS -- 2 BY BUCK BY OTHERS CH LTERNATE MOUNTING OPTIONgIA. UTSIDE MOUNT (WOOD) 8 INSTALLATION SCREW ANCHOR CAULK BETWEEN WINDOW FRAME AND BUCK 1900 SW 44TH AVE. BY OTHERS OCALA, FLORIDA 34474 TITLE E, \VERTICAL SECTION INSTALLATION DETAIL WOOD - 5200 ACRYLIC XX INSIDEINSIDE PA - I-S: 'Rr( 51 b, _ •;.(TE. PROPRIETARYANO CONFIDENTIAL RYL H R Z L DER BAT 1/31/200E THE INFORMATION CONTAINED IN THIS DRAWING IS THE SOLE PROPERTY OF CUSTOM <FJ^E' SCALt;, DN^J IJO.: WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WHOLE WITHOUT THE 5200152XO NT$ CWS-18. WRITTEN PERMISSION OF CUSTONI VANDOW SYSTEMS. INC. IS PROHIRITED. : ELV. LEI TER L'I.iEE 7; 1 O OF 11 CONCRETE/MASONRY CONCRETE/MASONRY-- BY OTHERS BY OTHERS CAULK BETWEEN FRAME ANDMINEDGEDIST.) OPENING BY INSTALLER I r- INSTALLATION ANCHOR. D EXTERIOR FINISH', 3/16" MASONRY ANCHOR BY OTHERS --j 4 7116"--"-{ 3 3/16" 1 114_' a.mF 00 . o 4 La MINEMBEDMENT) o0 1 BY WOOD BUCK BY OTHERS Id PERIMETER CAULK --- - BY OTHERS I DOORFRAME -/ HEAD I CAULK UNDER SCREW J HEAD BY INSTALLER EXTERIIOR INTERIOR 1 114' MIN. EMBEDMENT) 1/4" MAX SHIM SEE NOTE 2 & 3 SHEET 3) 1/4" MAX SHIM SEE NOTE 2 & 3 SHEET 3) INTERIOR 11 /2" MIN. EMBEDMENT) I--- CONCRETE/MASONRY J BY OTHERS D a 2 BY WOOD BUCK BY OTHERS D V CAULK BETWEEN A/ FRAME AND OPENIN( Al D BYINSTALLF_R a a- k CAULK UNDER SCREW 7 HEAD BY INSTALLER ---- INSTALLATION ANCHORLL Jd d #10 WOOD SCREW DOOR FRAME pMIN. EDGE DIST.) G oo. -DOOR FRAME JAMB o 0 l oo JAMB j% °•o.• o G oo°, BY OTHERS CAULK EXTERIOR ° oo A• 4 CAULK UNDER SCREW / • °' o •oP°°° HEAD BY INSTALLER oo • o - EXTERIOR FINISH PERIMETER CAULK -- \•----- EXTERIOR FINISHBYOTHERSBYOTHERSBYOTHERS JIHORIZONTAL SECTION 1 _I17 /R'\,HORIZONTAL SECTIONg. MULTIPANEL (1 BY BUCK) "" ••• 1-.- PERIMETER CAULK INSTALLATION ANCHOR, I BY OTHERS 3/16" MASONRY ANCHOR 1 -CAULK UNDER SCREW HEAD BY INSTALLER I OORFRAME SILL I i aPERIMETER CAULK ----1 \ II N BY OTHERS SET SILL IN BED OF CONCRETE OR GF THE ENTIRE LENGTH OF SILL TO n e n N n N SUPPORT ALL ANCHORS BY INSTALLER. 1 1/4" D D p IN. EMBEDMENT) CONCRETE/ MASONRY BY OTHERS ` - T-`, VERTICALSECTION 9,% MULTIPAFlE! (EXTERIOR SILL) E`. ALTERNATE SILL OPTION 7, - MULTIPANEL (INTERIOR SILLI PROPRIETARY AND CONFIDENTIAL THE INFORMATION CONTAINED IN THIS DRAWING 13 THE SOLE PROPERTY.OF CUSTOM WINDOW SYSTEMS, INC. ANY REPRODUCTION IN PART OR AS A WMOLE WITHOUT THE WRITTEN PERMISSION OF CUSTOM WINDOW SYSTEMS, INC. IS PROHIBITED. 9/ MULTIPANEL R BY BUCK) PERIMETER CAULK BY OTHERS i r1_ 1/4" MIN EMBEDMENT L 1900 SW 44TH AVE. OCALA, FLORIDA 34474 1 / 3112008 CWS-182 11 OF 11 4 . I PLOD" PLAN DESCRIPTION: (AS FURNISHED) LOT 125, PRESERVE AT LAKE MONROE AS RECORDED IN PLAT BOOK 62. PAGES 12-15 OF THE PUBLIC RECORDS OF SEMINOLE COUNTY, FLORIDA IuPMAMC 1"AACUl A1)ONS it.OT ONLY1 LOT 125 CONTAINS 6662 SOUARF FEET t (LOT ONLY) THIS STRUCTURE CONTAINS 2381 SQUARE FEET t TOTAL CONCRETE 492 (YItTH1N LOT ONLY) SO. FT, t TOTAL-§OQ 37159 PERCENT OF CMCRETE STRUCTURE TO LOT 43X c .Aw rmiy.ts na- in r u % LOT 125 UP TO CURB CONTAINS 7165 SQUARE FEET t THIS STRUCTURE CONTAINS 23al SQUARE FEET t 014CRETE 810 SO. FT. t MICLU(MG (SICIEwALK/APRON) JOTAL SOD 3974 SQ FT, t____ A-• 5'19'41 " L=46.50' R = 500.00' CB=N05.24'06"E C= 46. 48' BUILDING SETBACKS FRONT: 25' REAR: 20' SIDE: 5' CORNER: if, WREPARED FOR: CENTEX HOMES I, ELEVA,90NS SHOVIIN ARE PER LOT GRAOINO PLANS PROVIDED BY THE CLIENT. LIJ 1' GRAPRC SCALE su) 0 Is xP 0) 00 UNPLATTED k 34.94' 28.55' S00'00'24"E S09'06'41 "W LOT 125 L TYPE A e DRAINAGE CV i i O Yr 1 1 I 1 rl 1 11 1 1 i T 1 2 ye iL0i1L6 NW 192e " aEQ i t 1 7 qL. Q 1 1 2 4 L.LiIt FINISHED FLOOR n EL£vA910N-10 a pi r T SJ' 04 K In I6yam. 1 VN i jj y.,. O K! P 4• 1 z 21.3• O 1 J`ra 1 p U1111r EASEMENT 1 e-a»4°21i .R1.;+•'T+'e'—w-..Ash$ L• 75,0 L-a•ar j C9-NDa'wI9'ER.47S.OD' c1a-No4Yn'4e'e it c.a.a r C-ftaErN JfSOS• PT - PCRKIT-QFwAY R-4Y5.W Ce-N04 33"Da•E C.aa.s1• WALNUT CREST FAUN s0' MWT••O-WAY LEGEND al I.aNc ST:tBACx LINEMtwIN MINioM LOT WIDTH POLAR ON BOUNDARY CENTERLIK PCC POINT OF COMPOUND CURVATURE. R004T OF WAY LINE POC POINT ON CURVE FK PROPOSED ELEVATION 0* PD OFFICIAL RECORD PLANNED 1T£VELOPUChT f PROP06E0 DRAHAM FLOW A DENOTES DELI4 ANODE L DENOTES AK LENGD4 4 1 CONCRETE C.S. DENOES CNORD KAR°NG N * l9URhiY7N0 6USWE:tS 8 /Alp PC DENOTES POINT Of CUP ArVRE a , PI DEN0IES POINT OF WTERSECnON leaf If III If 11111111 it III :ll III II ill II 11111 ill II 111.1111111111 y r THIS INSTRUMENT PREPARED BY`. Name` jLvc+ 11 i 1 Address: j- W, v- I W v- StaWof Florida y SEAGNOLE COUNTY FLORIDA' S NATURAL CHOICE MARYANNE MORSra, CLERK OF CIRCUIT COURT SEMINOLE COUNTY BK 07073 pg 17821 Npg) CLERK' S # 2008112809 RECORDED 10/06/2008 01:03:51 pM RECORDING FEES 10.00 RECORDED BY T Smith Jr,- 00o0 12 Permit Number Parcel ID Number (PID) The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of Commencement. DESCRIPTION OF P OPERTY (Le g I desc iption of the p Qperty and stre t addre s if available) Irk . , i u l . 1°f .Z.'7/ CERTIFIED pRYANN y vA IT rolMnilRT COU TY, FLORIDA GENERAL' DESCRIPTION OF IMPROVEMENT {'L f) ' 'FNmomoFL OWNER INFORMATION Name and address: CONTRACTOR Name and address. e i l I,) day A 4r) (,, t v Persons within the State of Florida Designated by Owner upon whom notice or otherdocuments may be served as provided. by Section 713. 13(1)(b), Florida Statutes. Name and address: In addition to himself, Owner Designates of To receive a copy of the Lienor's Notice as. Provided in Section 713.13( 1)(b), Florida Statutes. Expiration Date of Notice of Commencement: The expiration date is 1 year from date of recording unless a different date is specified. WARNING_ TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE. THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF COMMENCEMENT. STATE OF FLORIDA COUNTY OF SEMINOLE O . NER IGNATURE t,/T OWNERS PRINTED NAME NOTE: Per Florida Statute 713.13(1) (g), owner must sign...... and no one. else may be permitted to sign in his or her stead." The foregoing instrument was ackno ledged efore me this day of L' , 20 Who isersonall p y knownto me I k Iaby C- iNameofperson making statement —, % OR who has produced identification type of identification produced VERIFICATION PURSUANT TO SECTION 92.525, FLORIDA STATUTES. UNDER PENALTIES OF PERJURY, I DECLARE THAT I HAVE READ THE FOREGOING AND THAT THE FACTS STATED IN IT ARE TRIBE TO THE BEST OF MY F NOWLEDGE AND BELIEF. 9 /1 -7 1 J Il . "--) RE OF NATURAL PERSON SIGNING ABOVE hANNELORE C.ELVESTE. i Notary Pub i Slate of Florida Aug 16, 2009hAyCommissi , p452522J,• M Commission # Nota Signature B National NotaryAssn. Bonded Y''. i