Loading...
1901 Sanford Ave - BR08-000623 (PORCH ADDITION) DOCUMENTSCITY OF SANFORD PERMIT APPLICATION Application # : ® —10d3 - i Submittal Date: 1, 11 OR Job Address: ii ^Vt Cd Value of Work: S_1 (fit/ Parcel ID: of _19 R) C y KddAAb" Zoning: t`S_ Historic District: lV 0 Description of Work: c Addi] 6f) Square Footage: (9 C Pemit Type: Building Electrical Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service — # of AMPS Addition/Alteration Change of Service Temporary Pole El Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Calc. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/New Residential: # of Water Closets Plumbing Repair —Residential Commercial Occupancy Type: Residential A Commercial Industrial Occupancy Use Group(s): R_92 Construction Type: V__f5__ # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required ) Property Owner: fb(%y--e _ Contractor: Address: ' Address: L Z7 I I Phone: E-mail: 1-C Q 6Kn >'(Phone: State License Number: Bonding Company, J Mortgage Lender: Address: Address: Architect/Engineer: 0 lam{ 1/07 O Z 1FOSF/ Phone: 4DI, 222.<< -7-113 Address: ,(( Fax: J o 15• Plan Review Contact Person:UAffi, I Phone:`L+ Z,SA Fax: :1-75.gi'7 E-mail f' Gj(Ylal. Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. OWNER'S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water management districts, state agencies, or federal agencies. ccep n e erm Recation that I will notify the owner of the property of the requirements of Florida Lien Law, FS 713. l• t.Ce) Si afore of ner/Agent Date Signature of Contractor/Agent Date Pr Owner/Agent's Name Print Contractor/Agent's Name o I nature of Notary -State of Florida r// Signature of Notary -State of Florida Date ary16 ,q"J_ 5 C;u,• Owner/Agent is Personally Known t-arm ale n a =Contractor/Agent is _ Personally Known to Me or Produced ID V 1 p' ;, Produced ID i G APPROVALS: ZONING: Special Conditions: Rev 07.07 lfD UTILOan:<: NoufENG: I Sid.` Seminole County Property Appraiser Get Information by Parcel Number Page 1 of 2 1A 3A 1.0 16 DAVID JOHNSON, Cr•A, ASA 1 to—G. 3.0 4 PROPERTY6. 0 5.0.E$A 0 APPRAISER 1.07 100.A SEMINOLE COUNTY FL. 1 3 0 1'Ai j P O 100.0 1i[2 1101 E.FIRSTsT 21.0 5.0, IT1t 102.0 SANFORD, FL3=1.1468 2.0 1 13407 - 66b - 75 10.0 23.0 K P a it4 15A 1 I 1 51.0 2008 WORKING VALUE SUMMARY Value Method: Market GENERAL Number of Buildings: 1 Parcel Id: 31-19-31-511-0000-0070 Depreciated Bldg Value: $184,094 Owner: FORREST ANDREW G JR & DIANE C Depreciated EXFT Value: $16,417 Mailing Address: 1901 SANFORD AVE Land Value (Market): $62,475 City,State,ZipCode: SANFORD FL 32771 Land Value Ag: $0 Property Address: 1901 SANFORD AVE SANFORD 32771 Just/Market Value: $262,986 Subdivision Name: ROSE COURT Assessed Value (SOH): $143,342 Tax District: S1-SANFORD Exempt Value: $25,000 Exemptions: 00-HOMESTEAD (2003) Taxable Value: $118,342 Dor: 01-SINGLE FAMILY Tax Estimator Tax Reform Calculator SALES 2007 VALUE SUMMARY Deed Date Book Page Amount Vaclimp Qualified Tax Amount(without SOH): $4,482 WARRANTY DEED 08/2003 04980 0545 $100 Improved No 2007 Tax Bill Amount: $2,143 WARRANTY DEED 09/2002 04558 1786 $166,000 Improved Yes Save Our Homes (SOH) Savings: $2,339 WARRANTY DEED 12/2001 04291 0494 $124,000 Improved Yes 2007 Taxable Value: $114,846 DOES NOT INCLUDE NON -AD VALOREM Find Comparable Sales within this Subdivision ASSESSMENTS LAND LEGAL DESCRIPTION Land Assess Method Frontage Depth Land Unit Land Units Price Value Pick PLATS: FRONT FOOT & 140 155 .000 425.00 $62,475 LEG LOTS 7 + 8 ROSE COURT PB 3 PG 3 DEPTH BUILDING INFORMATION Bid Bid Type Year Bit Fixtures Base SF Gross SF Living SF Ext Wall Bid Value Est. Cost New Num 1 SINGLE 1951 6 2,216 2,855 2,216 BOCKONC $ 184,094 $225,882 FAMILY Appendage / Sgft OPEN PORCH FINISHED / 72 Appendage / Sgft UTILITY UNFINISHED / 105 Appendage / Sgft GARAGE UNFINISHED / 462 NOTE: Appendage Codes included in Living Area: Base, Upper Story Base, Upper Story Finished, Apartment, Enclosed Porch Finished,Base Semi Finshed Permits re_web. seminole_county_title?parcel=31193151100000070&cpad=sanford&cpad_num=19(1 / 11 /2008 111111e lie Teel 11 ill Il Ill li elt el lie 11 oil ii ell 110 N Ill I loll I NOTICE OF COMMENCEMENT Permit No. m Parcel ID: '2j L- 3I- State of Florida County of Seminole MARYANNE MQR k-,. CLERK OF CIRCUIT COURT SEMINOLE COUNTY 8K 06923 Pq 1347; ilpq) CLERK'S ## 2008014003 RECORDED 02/06/22008 01112140 PM RECORDING FEES 10.00 RECON00 BY L McKinley The undersigned hereby gives notice that improvement will be made to certain real property, and in accordance with Chapter 713, Florida Statutes, the following information is provided in this Notice of.Commencement. 1. Description of property: (legal description `of the property an street address if available) r S2,1 2. General description of improvement: 3. Owner Information ii a. Name and address: ylt l 1. lV- ,,-e y'6,A -2" b. Interest in property: Uc r1 r = 1li c. Name and address of fee simple titleholder (if other than owner) _ 4. Contractor a. Name and address: b. Phone Number: 5. Surety a. Name and address: b. Amount of bond $ c. Phone Number: 6. Lender a. Name and address: b Phone Number: HwNE ,MORSE OF CIRCUIT COURT Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Section 713.130)(a)7., Florida Statutes: a. Name and address: h Phnna Nnmher- 8. In addition to himself or herself, Owner designates the followingperson(s) to receive a copy of the Lienor's Notice as provided in Section 713,13(1) (b), Florida Statutes: a. Name and address: b. Phone Number: 9. Expiration date of notice of commencement (the expiration date is I year fi-om the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTINCE OF COMMENCEMENT ARE CONSIDERED IMPROPER PAYMENTS UNDER CHAPTER,713, PART 1, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH UR, L TORNEY BEFORE COMMENCING WORK OR RECORDING YOUR NOTICE OF CO! M N E N . ll IIS 1VTRUMEN'l PREPARED BY: rr l Signature o Owner or Ow er's Authorized Officer/Director/Partner/Manager ADDR. J &k Signatory's Title/Office C The foregoing tnstr ent was acknowle l before me this,Iay of 1 20 () by .• Y 9 "•yt1 ar t• at3 t rre' (name of peisort_ (type of authority ...e.g. officer, trustee, attorney in name of art on behalf of whom instrument was executed). fact) for e i T C' %.— ( party Signature of Notary Public, Commission Expires: 4atteOf Ftbrida Cis A T{ • o v r. OWNER BUILDER STAiEME1VT/AFFIDAVIT Altamonte Springs, Casselberry, Lake Mary, Longwood, Oviedo, Sanford, Seminole County, Winter Springs Florida Statutes are quoted here in part for your information to indicate the authority for exemptions for homeowners from qualifying as contractors and to express any applicable restrictions and responsibilities. OWNERS MUST PERSONALLY APPEAR AT THE BUILDING DIVISION TO SIGN THIS DOCUMENT FSS 489.103 Disclosure Statement State Law requires construction to be done by licensed contractors. You have applied for a permit under an exemption to that law. The exemption allows you, as the owner of your property, to act as your own contractor with certain restrictions even though you do not have a license. You must provide direct, onsite supervision of the construction yourself. You may build or improve a one -family or two-family residence or a farm outbuilding. You may also build or improve a.commercial building, provided your costs do not exceed $75,000. The building or residence must be for your own use or occupancy. It may not be built or substantially, improved for sale or lease. If you sell or lease a building you have built or substantially improved yourself within 1 year after the construction is complete, the law will presume that you built or substantially improved it for sale or lease, which is a violation of this exemption. You may not hire an unlicensed person to act as your contractor or to supervise people working on your building. It is your responsibility to make sure that people employed by you have licenses required by state law and by county or municipal licensing ordinances. You may not delegate the responsibility for supervision work to a licensed contractor who is not licensed to perform the work being done. Any person working on your building who is not licensed must work under your direct supervision and must be employed by you, which means that you must deduct F.I.C.A and withholding tax and provide workers' compensation for that employee, all as prescribed by law. Your construction must comply with all applicable laws, ordinances, building codes, and zoning regulations. BY SIGNING THIS STATEMENT, 1 ATTEST THAT: (Initial to the left of each statement) I UNDERSTAND AND AGREE TO THE EXEMPTION PROVISIONS OF FLORIDA STATUTES 489.103 AS LISTED ABOVE. I HAVE ACCESS TO THE ADOPTED CODES. 1 AM FAMILIAR WITH THE CODE PROVISIONS. I HAVE ADEQUATE KNOWLEDGE AND QUALIFICATIONS TO SAFELY PERFORM AND DIRECTLY SUPERVISE THE WORK. THIS PROPERTY IS NOT AN APARTMENT, CONDOMINIUM OR RENTAL PROPERTY. THIS STRUCTURE IS NOT BEING BUILT WITH MY INTENTION TO SELL, RENT, OR LEASE. I UNDERSTAND THAT THERE IS NOT STATED A TIME FRAME TO SELL, RENT OR LEASE AN OWNER BUILDER STRUCTURE WITHOUT BEING INVESTIGATED. I UNDERSTAND THAT FOR ANY UN -LICENSED PERSON 1 HIRE, I MUST DEDUCT F.I.C.A., WITHHOLDING TAX, AND PROVIDE WORKERS' COMPENSATION INSURANCE. V,v Property Add 1, h L "1 5 pre S_ , do hereby state that I am qualified and capable of performing the requeslod--69nstructiRkinvolved with the permit application filed. Signature Ln I M Date Form of Identification r L. `I,ZL. _ *.' Must be Photo IS o icy A violation of this exemption is a misdemeanor of i ,first degre ti . gable by a term of imprisonment not exceeding 1 year and a $1,000.00 fine in addition y evil°,'pe In addition, the local permitting jurisdiction shall withhold final approval, revoke the tr, Ind any action or remedy for unlicensed activity against the owner and any person performing wfir'Ido'tI uires licensure under the permit issued. Rev. 4/20/07) r Permit #: Project Name: 08-623 1 Residential Addition Address: 1901 Sanford Ave. Plans Reviewed By: Richard Denman 02/05/2008 407.330.5656 The Permit Is Subject T® The Following Comments THE FOLLOWING ARE STANDARD COMMENTS: NOTICE: In addition to the requirements of the Permit there may be additional restrictions applicable to this property that may be found in the Public Records of this County and there may be additional Permits required from other Governmental entities such as Water Management Districts, State Agencies or Federal Agencies. l . This approval does not grant permission to violate any applicable Codes. 2. Inspections will not be given unless the Approved plans and Permit are posted in a prominent location and protected from the elements until all inspections are complete. 3. Any connections that may be hidden during the installation shall be inspected prior to covering. 4. The Permit shall expire if work has not begun within six months of the date of issuance. 5. All Permits require Final Inspections. Failure to do so may result in permitting rivileges being revoked as well as charges being filed with the DBPR. 6. Your attention to "Notes" written on the Plan pages is requested. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, CONSULT YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. SECTION 713.135 FLORIDA STATUTES. dLs,R Wp wSmKL" d j T } v k U PiWll # 9 Z, 3 DATE: n 10 fi PLAT OF BOUNDARY SURVEY SET NAIL & DISK LB#6948 . LLJ r Z 3 LiJ a Q E Zc=aaCe Qa L 0 g A/ 1IOL. n U— Q U) I N In C d DESCRIPTION (As Furnished) LOT 7 & 8, ROSE COURT ADDITION TO SANFORD, according to the plat thereof as recorded in Plat Book 3, Pages 3 of the Public Records of Seminole County, Florida, Asphalt Pavement 50' PLATTED RIGHT OF WAY GRANDVIEW AVENUE SET 1/2" IRON SET 1/2- IRON ROD AND CAP L8e!6948 35.00' LRB#6948 OD AND CAP FOUND 3/8--IRON FENCE CORNER r FENCE CORNER L;79.43(M)80'(P) ROD NO NUMBER IS 6.3' S N90 OU 00 E 1s 0.1' s Tan-40.1 s22o.00 PT r7 n PC DRIVE N DRIVE Uv 4.7 v 35.7' v 3 I FOUND 3/4" IRON n PIPE NO NUMBER WALK IS 1.0' OFF col n rnl FOUND 1/2' IRON ROD NO NUMBER N 155'(P) g SINGLE STORY RESIDENCE #1901 26.7 POOL 155, (P) 154.67' N9f WALL CORNER IS 0.5'N NOTE: A TITLE COMMITMENT, WHICH MAY OR MAY NOT REFLECT ADDITIONAL DOCUMENTATION, HAS NOT BEEN FURNISHED TO THIS FIRM, THEREFORE, NO ADDITIONAL DOCUMENTATION WHICH MAY OR MAY NOT AFFECT THIS SURVEY HAS BEEN REFLECTED ON THIS SURVEY. IF ADDITIONAL DOCUMENTATION IS FURNISHED, THIS SURVEY MAY BE SUBJECT TO CHANGE. LOT 10 Based on the FEDERAL EMERGENCY MANAGEMENT AGENCY, NATIONAL FLOOD INSURANCE PROGRAM, FLOOD INSURANCE RATE MAP, Seminole County, Florida, Community Panel Number 120294 0045 E. lost dated 4/17/95, it appears from a scaling of said map that the land described hereon is shown to be in Zone "X", AREA OF MINIMAL FLOODING) Said map is not a Survey and no responsibility a taken for the information contained in or the accuracy of the above referenced map. i I. This Plat represents a Boundary Survey of the description os- f mished Harrison Surveying and Mapping, Inc. per client's instruction and makes no claims regarding ownership or rights of possession. 2. Bearings shown hereon are based on the EAST line of Lots 7 and 8, Being N 00'1536' W, PER PLAT. 3. This surveyor has not searched the public records -or abstracted the land'shown hereon for easements, right of ways, covenants and restrictions or other pertinent documents which may be found in the public records of this county. This research was not included in the scope of services of this firm. 4. The relative distance accuracy for boundary dimensions shown hereon is in excess`6V 1, Foot in 10,000 Feet- 5. Underground improvements and utilities have not been located. 6. This, survey performed by Harrison Surveying and Mapping, Inc. is for the singular use by the clients named hereon for the express stated purpose listed hereon. This drawingisnotjegailybindingwithoutmysignatureandoriginalraisedembossedseal. No third party is authorized to use this drawing in any way, and this surveyor shall not 6e held liable for damages resulting from the unauthorized or illegal executionsorattemptsatcircumventingprescribedlawsorprofessionalfeepayments. All plats, reports, notes, plans, specifications, computer files, field notes or data, other documents and instruments prepared by this firm as instruments of service shall remain the property of this firm. This firm shall retain oil common low, statutory and other reserved rights, including the copyright thereto. The originalofthisdrawingremainsthepropertyofHarrisonSurveyingandMapping, Inc.. HARRISON SURVEYING AND MAPPING, INC. PROFESSIONAL SURVEYORS AND MAPPERS i Certificate of Authorization {LB 6948 32529 Okalooso TrailTASorrento, Florida 32776 Phone: (352) 735-1263 JOB NO. 01-3325D Sheet 1 of 1 FENCE IS 12, D.5' ON v Z s N 24.4" a t7-4-- ------- 0040 mr.04 LOT 8' POOL EQUIP_ ^ ON CONC. 6' caw WALL & FENCE ' CORNER IS 0.3' N FOUND 3/8-IRON ROD NO NUMBER CERTIFIED TO: DIANE FORREST ANDREW G. FORREST, JR REVISIONS AND ADDITIONS 19-10-021 UPDATE 111-1-071 UPDATE N FOUND 3/8" IRON ROD NO NUMBER I I r D I l I D r Im o I I I I SCALE: 1 " = 30' LEGEND: p = Delta (Intersection Angle) DENOTES CONCRETE R = Radius L Are Length - WF Woad Fence C.H. Chord 8eanng (M) = Measured Ch = Chord Length CBW = Concrete Block Wall P.C. = Point of Curvature PI = Point of Intersection P.T. = Point of Tangency CNF = Corner not found P.B. = Plot Book SLY = Southerly Pg.(s) = Page(s) NLY = Northerly Conc. = Concrete ELY = Easterly - - C.L.F. Chain -Link Fence WLY. = Westerly A/C = Air Condition B S-L. = Building Setback Line R W = Right —Of —Way A) = Actual CONC.= Concrete P) = Plat C Centerline El = REC 0 = REC C(D__ = OHUL DENOTES OVER HEAD UTIUTY LINES DRAWING: 01-3325D.DWG SURVEY DATE: 1/2/02 INTENDED DISPLAY SCALE: 1" = 30' DRAWN: DSW EXPECTED USE OF THIS LAND: RESIDENTIAL PURPOSES IT 1S CERTIFIED THAT THE SURVEY REPRESENTED HEREON MEETS OR EXCEEDS THE MINIMUM TECHNICAL STANDARDS AS SET FORTH IN CHAPTER61G17-6 FLORIDA ADMINISTRATIVE CODE,'PURSUANT TO SECTION 472.027, FLORIDA STATUTES. NOT VALID WI OUT Er,51GN TORE AND THE ORIGINAL RAISED SVAL OF A LORT LICENSED SURVEYpR/AN MAPPER DOUGLAS S. WILLIS, Florida Registration 5984 FOR THE FIRM: January 29, 2008 Mr. Richard Denman Plans Examiner/Building Inspector City of Sanford Building Fire and Prevention Division P.O. Box 1788 Sanford FL 32772 RE: Andrew and Diane Forrest Residence Porch Addition Permit App. No. 08-623 Dear Mr. Denman - Thank you for your review comments dated January 25, 2008 regarding the Forrest Residence Porch Addition. Below please find responses to the comments. S-1 Provide the door and window manufacturer's Florida Product Approval documentation and installation instructions for all. Response: The porch addition will not be conditioned space and therefore, will not be enclosed with glass windows and doors. The windows and doors will be custom fabricated from fiberglass screen and wood trim. Please see notes on elevations Det.'s 2 & 4, Sheet 3 S-2 The plans do not indicate / provide a detail for attachment of the new masonry walls to the existing structure's masonry wall. Response: Please see attached detail 1/1, -"CMU to Existing CMU Wall", dated January 29, 2008. S-3 The 4" wide masonry walls, indicated on the plans at Detail 1/1, do not comply with the 2004 Florida Building Code, Residential Section R606.1 as stated in the "Notes To Drawing" on Plan page 1. Section R606.2 requires the exterior walls to eight inches or shall be designed in accordance with Section R606.1 ". If the 4" wall thickness is correct please provide all engineering and testing data for the 4" masonry walls. Response: The new masonry walls will be constructed of 8" wide x 4" high x 16" long CMU to match the existing house with the exception of the single base course shown in Det. 1/2. References to 4" CMU on the plans are to mean 4" high CMU. All new CMU walls are 8" wide. S-4 There appears to be other notes on Plan page 2 that causes a conflict between the masonry block sizes. Please clarify. Response: Per the response to item S-3 above, all new CMU walls will be constructed of 8" W. x 4" H. x 16" L. CMU except as shown in Det. 1/2. This is because the existing porch slab is sloped to from north to south (top of slab elevation difference of 2".) So the bottom course along the east wall will be constructed of 8"CMU and cut from 8" high at the low end of the slab to 6" high on the high endof the slab in order to provide a level course for the rest of the CMU wall above. This is how the base of the existing west wall is constructed. The 8" cut block is shown at the base of the elevations 3 and 4, sheet 3. The single 8" block course is also shown on detail 1, sheet 2 however, it was not clearly noted. Mr. Denman, I hope the above responses clarify your review of the drawings. Please do not hesitate to contact me if you require additional information on these responses or the project plans. Best Regards, Diane S. Chan y, FL AR 0015480 Attached — Det. 1 /1 lac. Opdc7 . CM WALL Goi2E E e ex. lr`Jr L.L . C al tT cxoLlp e 4W e Mli Oew R.EIt, GMo Vl"&,L— C--mo To tz-,Ig G U- 1001 r R*-O k\/E , FL A r CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION PO BOX 1788 SANFORD FLORIDA 32772 PHONE: 407.330.5656 FAX: 407.328.3859 PLAN REVIEW COMMENTS Date: January 25, 2008 Contact Person: Andrew Forrest Contact Phone Number: 407-302-8041 Contact Fax Number: 386-775-9867 Contact E-mail Address: dforrest@embarqmail.com Permit Application Number: 08-623 Project Description: Room Addition Job Address: 1901 Sanford Ave. The following is a list of the areas of the submitted plans that contained violations of the codes adopted by the City of Sanford and enforced by the Building Division. The violations noted must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal. Changes to construction documents that require an Architect or Engineer's seal must be submitted with the appropriate seal. STRUCTURAL 1 Provide the door and window manufacturer's Florida Product Approval documentation and installation instructions for all. W<2 The plans do not indicate / provide a detail for attachment of the new masonry walls to the existing structure's masonry wall. V/ 3 The 4" wide masonry walls, indicated on the plans at Detail 1/1, do not comply with the 2004 Florida Building Code, Residential Section R606.1 as stated in the "Notes To Drawing" on Plan page 1. Section R606.2 requires the exterior walls to eight inches or shall be designed in accordance with Section R606.1". If the 4" wall thickness is correct please provide all engineering and testing data for the 4" masonry walls. S-4 There appears to be other notes on Plan page 2 that cause a conflict between the masonry block sizes. Please clarify. Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Please direct any questions you may have to Richard Denman at 407.330.5656 or fax to 407.328.3859. You may also contact me by E-mail at denmanr@sanfordfl.gov. Respectfully, Re?l and V ew*" V&ad .5=M = / 6ui d, y lw#am 1- CITY OF SANFORD BUILDING AND FIRE PREVENTION DIVISION PO BOX 1788 SANFORD FLORIDA 32772 PHONE: 407.330.5656 FAX: 407.328.3859 PLAN REVIEW COMMENTS Date: January 25, 2008 Contact Person: Andrew Forrest Contact Phone Number: 407-302-8041 Contact Fax Number: 386-775-9867 Contact E-mail Address: dforrest@embarqmail.com Permit Application Number: 08-623 Project Description: Room Addition Job Address: 1901 Sanford Ave. The following is a list of the areas of the submitted plans that contained violations of the codes adopted by the City of Sanford and enforced by the Building Division. The violations noted must be addressed before the plans can be approved. Changes to plans shall be submitted on the same size format as the original submittal. Changes to construction documents that require an Architect or Engineer's seal must be submitted with the appropriate seal. STRUCTURAL 1 Provide the door and window manufacturer's Florida Product Approval documentation and installation instructions for all. W<2 The plans do not indicate / provide a detail for attachment of the new masonry walls to the existing structure's masonry wall. V/ 3 The 4" wide masonry walls, indicated on the plans at Detail 1/1, do not comply with the 2004 Florida Building Code, Residential Section R606.1 as stated in the "Notes To Drawing" on Plan page 1. Section R606.2 requires the exterior walls to eight inches or shall be designed in accordance with Section R606.1". If the 4" wall thickness is correct please provide all engineering and testing data for the 4" masonry walls. S-4 There appears to be other notes on Plan page 2 that cause a conflict between the masonry block sizes. Please clarify. Any error or omission in this plan review shall not be construed to grant approval of any violation of any of the adopted codes or municipal ordinances of this jurisdiction. Please direct any questions you may have to Richard Denman at 407.330.5656 or fax to 407.328.3859. You may also contact me by E-mail at denmanr@sanfordfl.gov. Respectfully, Re?l and V ew*" V&ad .5=M = / 6ui d, y lw#am 1- 12 hp LaserJet 3015 HP LASERJET FAX Jan-25-2008 10:12AM Fax Call Report i n v e n t Job Identification Duration Pages Result 93867759867 1:00 1 OK Date Time Type 367 1/25/2008 10:11:28AM Send