Loading...
2500 S French Ave - E08-000793 (REWIRE TRACT LIGHTING RELOCATE SWITCH) DOCUMENTSCITY OF SANFORD PERMIT APPLICATION C 1 Application #: Submittal Date: Job Address:n i` r f` l ) 1-1 Vim_ D Value of Work: $ 0( Parcel ID: \_ — 't0— `b0H —` CA Zoning: ^`^ Historic District: Description of Work: &, , ni'm #c 0.C_t' l O.Ti An CA SWi)C .tf 1 Square Footage: Permit Type: Building Electrical 0 Mechanical Plumbing Fire Sprinkler/Alarm Pool Sign Electrical: New Service — # of AMPS Addition/Alteration Change of Service TemporaryPole Mechanical: Residential Non -Residential Replacement New (Duct Layout & Energy Cale. Required) Plumbing/ New Commercial: # of Fixtures # of Water & Sewer Lines # of Gas Lines Plumbing/ New Residential: # of Water Closets Plumbing Repair —Residential Commercial Occupancy Type: Residential Commercial 0 Industrial Occupancy Use Group(s): Construction Type: # of Stories: # of Dwelling Units: Flood Zone: (FEMA form required) 1.................... j.......................................... Property Owner: A-X f) Den6\ i C-10 P PfL I( Contractor: QV "h Address: 9 0 rJLi W Add r/ss 7 L A7 )car c 2% , 6 05 SS Ap k . 'El . Phone: E-mail: Phone: State License Number: Bonding Company: Address Mortgage Lender: Address: Architect/. Engineer: m Phone: Address \ 1— L 7J 4` i a- Fax: Plan Review Contact Person: Crc, %Ok P Q,`IQ Phone: —Fax: t-(Li'_l• 4%M—OPR4 E-mail: CO ' ').Corn 'M 15io' 1- c Application is hereby made to obtain a permit to do the work and installations as indicated. I certify that no work or installation has commenced prior to the issuance of a permit and that all work will be performed to meet standards of all laws regulating construction in this jurisdiction. I understand that a separate permit must be secured for ELECTRICAL WORK, PLUMBING, SIGNS, WELLS, POOLS, FURNACES, BOILERS, HEATERS, TANKS, and AIR CONDITIONERS, etc. I OWNER' S AFFIDAVIT: I certify that all of the foregoing information is accurate and that all work will be done in compliance with all applicable laws regulating construction and zoning. WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT, IN YOUR PAYING TWICE FOR IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED, ON THE JOB SITE BEFORE THE FIRST INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. NOTICE: In addition to the requirements of this permit, there may be additional restrictions applicable to this property that may be found in the public records of this county, and there may be additional permits required from other governmental entities such as water panagement districtistate agencies, or federal agencies Acceptance of permit is verification that I will notify the owner of the property of requiremen s o FI fida Lien Law, Ff 713: Gg Signature of Owner/Agent Date Signature o Contractor/Agent Date or? C Print Owner/Agent's Name Print Con actor/Agent's N C Signature of Notary -State of Florida Date Signature otary-State of Florida e o X n n ii c Z m Owner/ Agent is _Personally Known to Me or Contractor/Agent is_/ Personally Known to Me or m N v Produced ID _ Produced ID 3 $ J Cn a APPROVALS: ZONING: UTIL: FD: ENG: BLDG: 4 Special Conditions: % ~ [ Q9 Rev 07.07 "5 0 ` P E T R L E U M CONSTRUCTION SERVICES INC. Building & Zoning Department TO WHOM IT MAY CONCERN: I hereby give my Power of Attorney to v goaq to sign for and obtain permits in the city of c unty of for the project listed below. Sincerely, l - Richard A. Quinn Vice President, Sales and Marketing CBC035082 PCC045042 EC13001928 CFC046990 CMC053199 CUC056663 State of Florida County of Orange iTheforegoinginstrumentwasacknowledgedbeforemethis 'G Richard A. Quinn, who is personally known to me or who has produced ID) as identification and who did/did not take an oath. Notary Public State of Florida at Large k 20 C&_by type of My Commission Expires: ow PV. Notary Public State of Florida Eleanor Bernice Ryan P My Commission DD572081cl OF Expires_ 08/05/2010. 2173 Platinum Road Apopka, Florida 32703 T. 407.880.0850 F. 407.889.0930 License #CBC035082 L MOP SINK — WATER PURIFICATION SYSTEM SPRINKLERRISERS PAPER/FOIL DISPENSER REFRIG. BELOW MST, 5.S. COUNTERTOP RETWERMALIZER— 77 OVE r.IFiY9-0 O HEAT STAND X3WILDBEANky Mit T CAFE ` CUP DISP. BELOW 1 0 COUNTERTOP I IT DI5PLAY GAPPUOGINO RACK MAKER CUPS BELOW IL_&, COUNTER TYP. CONDIMENT ISLAND COFFEE D15PL AY COUNTER SHELVING BELO W COUNTERTOP VERIFY LOCATICN OF MIGRCXLIAVE, GGTV- RECORDER VCR —'LOCKABLE CAB. MONITOR i 2-DR COKE HOT 5HELV. SANDWICH EXISTBY POWEIJ REFRIG. BELOW SHELV. ON POLE POST TO I COUNTER S LLHEEL REMAIN I i 2 TIS1 1_ WB GRAPHIC BANNER MOUNTED ON CEIL MG DUAL VD GAS METER SODA SPORTS DRPKS W MONITOR TRASHCAN T \ PAPERTOIIIEL iF UNITS G SHELVING / Z < UNITS / c W Z® / MONITOR < H Wa®II® UTENSILS / m i LIDS / OF >w 0 m U. BULK U-p, LIDS C Pd'I1 WITH FIRE x U BEL50W / / TOBR 3 EXTINGUISHER vx J ---' C L POLE G POWERPOLEPOSTTO ICE GRAM CASE I cot B-I-B ___ a$'> REMAIN SALES AREA snw ® ADA TRASH TABLE GAB ' BULK Q EEE] ' L_— I O O I TRAE44 TRASH I I 4200 WBC - NEW POWER PLAN FULL SIZE PRINT: 1/4' . F-0' 0 DI 2y 4 IIXI'l PRINT, VS" I'-C' 4' J m 4' a' SCALE: 1/4" = V-01 AMIPM 4200 KOP EQUIPMENT SCHEDULE -- POWER MARK OTY ITEM SKU MANUFACTURER] SUPPLIER - DESCRIPTION ELECTRICAL REMARKS PH AMP KVA HP TOBR 1 EXISTING -- RELOCATE SELF-SERVICE BAKERY MERCHANDISER T09R 1 EXISTING -RELOCATE 48-L SELF -SERVE REFRIGERATED LOW PROFILE DELI CASE r12T14R1EXISTING -RELOCATE MICROWAVE T15A 1 GA TO ORDER, NOT CHARGE GEHL'S CHILI 8 CHEESE DISPENSER UNITS (DUAL) 1 20 0.2 T16C 1 NWAS-D43129 N. WASSERSTROM LARGE CONDIMENT BAR - 90.625-W x 42'D 120 1 12.5 60 HZ T17 1 HAT-AFST.00002 HATCO CORP. AFST - 2X ARCO SLIDING DOOR CUSSIDE 208 11.7 1 .845 USES NEMA 14-20P B08 1 WASS-121659 WASSERSTROM PRINCE CASTLE 297-T40 BUN TOASTER 115 13 1.5 60 HZ BOOT 1 WASS-810536 WASSERSTROM TIMER - 6 CHANNEL VERTICAL (VERIFY IF REO'D.) 135 1 IO.la5 I AUXILIARY OUTLET 500 µ.'ATTS ELECTRKAL SYMBOLS 5YMBOL DESCRIPTION IG ISOLATED GROUND QQ JUNCTION BOX SIMPLEX RECEPTACLE DUPLEX RECEPTACLE 206V 17 OR 206V 37 RECEPTACLE DUPLEX ISOLATED GROUND RECEPTACLE tIf DUPLEX GROUND FAULT PROTECTED BREAKER NON -FUSED DISCONNECT &DITCH SINGLE POLE TOGGLE SWITCH, 20 AMPERE RATED, MOUNTED 443" AFF. UNLESS NOTED OTHERWISE. SUB5CRIPT, a" - LOVER CASE LETTER INDICATES SWITCH CONTROL. P" - DENOTES LIGHTED HANDLE TOGGLE SWITCH, LAMP IN SWITCH SHALL LIGHT WHEN EQUIPMENT IS OP''ERATNG. ELECTRICAL GENERAL NOTES A. THE E.C. SHALL EXAMINE FIXTURE LEGENDS AND RELATED MISCELLANEOUS DETAILS BEFORE PROCEEDING WITH ANY ROUGH - IN WORK. B. ALL ELECTRICAL WORK SHALL COMPLY WITH THE REQUIRED ELECTRICAL CODE AND ALL LOCAL AMENDMENTS. C. ALL EQUIPMENT SHOWN OR INDICATED ON PLAN SHALL CONFORM WITH LATEST N.S.F. STANDARDS, N.F.PA. REGULATIONS AND LOCAL BUILDING CODES. D. FOR EQUIPMENT REQUIRING ELECTRICAL POWER TO OPERATE, FINAL CONNECT, WIRING, HOOK UP, ETC. SHALL BE DONE BY THE E.C. E. ALL WIRING SHALL BE INSTALLED IN CONDUIT, FLEXIBLE METAL CONDUIT CAN BE USED IN LENGTHS NOT TO EXCEED 6'-0' ALTERNATE WIRING METHODS MAY BE USED IF ACCEPTABLE BY LOCAL CODE AND APPROVED BY THE ENGINEER. F. ALL CONTINUOUS SLEEVES TO HAVE LONG SWEEP ELBOWS. G. ALL ELECTRICAL PRODUCTS AND MATERIALS SHALL CONFORM TO APPLICABLE NEMA STANDARDS AND SWILL BE UL LUSTED. H. ALL 15, 20 AND 30 AMPERE 120V SINGLE PHASE RECEPTACLES IN THE UTILITY AREA, KITCHEN/FOOD PREP AREAS, AND WITHIN 6'-0. OF ALL SINKS WILL HAVE GFI RECEPTACLES. RECEPTACLES WILL BE EITHER HUBBELL #GF-5362 OR SLATER #SIR-20-F, OR APPROVED EQUAL BY PASS & SEYMOUR OR LEVITON. I. ALL NEW SIMPLEX RECEPTACLES WILL BE ONE OF THE FOLLOWING: HUBBELL #5361, SLATER #5361-AG, OR APPROVED EQUAL BT PASS SEYMOUR OR LEVITON. J. IF THERE ARE ANY DISCREPANCIES WITH THIS DRAWING, CONTRACTOR TO CONTACT THE ENGINEER OF RECORD. K. E.C. SHALL ROUTE NO MORE THAN (3) CURRENT CARRYING CONDUCTORS PER 3/4- CONDUIT. IF E.C. DECIDES TO ROUTE MORE THAN 3) CURRENT CARRYING CONDUCTORS PER CONDUIT E.C. IS TO FOLLOW GUIDELINES OF THE REQUIRED ELECTRICAL CODE. L. ELECTRICAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS. M. IF REQUIRED, E.C. TO PROVIDE AND INSTALL WIREMOLD #ALTP-2S, ANODIZED ALUMINUM, 10'-5", POWER POLE(S) WITH FACTORY INSTALLED 20A, 120V DUPLEX RECEPTACLES. CONTACT WIREMOLD AT: 860-523-8704 OR EMAIL AT SPQUOTEOWIREMOLD.COM. POWER PLAN KEYNOTES: D EXISTING AREA TO REMAIN AS IS UNLESS NOTED OTHERWISE. O E.C. TO ROUTE (2) #12 AND (1) #12 GROUND IN 1/2" CONDUIT TO AVAILABLE 120V, 20A BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT E.C. TO PROVIDE AND INSTALL BREAKER. OEXISTING EQUIPMENT TO BE RELOCATED. E.C. TO RELOCATEJUNCTIONBOX/ RECEPTACLE AND EXTEND WIRE AND CONDUIT AS REQUIRED. E.C. TO MOUNT RECEPTACLE ABOVE TABLE AND BELOW WALL MOUNTED SHELF, SO UNIT CAN BE SET BACK TO THE WALL O E.C. TO ROUTE (3) #12 AND (1) #12 GROUND IN 1/2- CONDUIT TO AVAILABLE 120V. 20A BREAKER IN ELECTRICAL PANEL. IF NO SPARE BREAKER PRESENT, E.C. TO PROVIDE AND INSTALL BREAKER. E.C. TO PROVIDE AND INSTALL CLASS "A" 5mA GROUND FAULT BREAKER IN PANEL. OE.C. TO FIELD VERIFY EXISTING ELECTRICAL OUTLETS ON THIS WALL. INSTALL NEW OUTLETS AS REQUIRED PER CUT SHEETS, OR RELOCATE JUNCTION BOXES / RECEPTACLES AND EXTEND WIRE AND CONDUITS AS REQUIRED. REMOVE UNUSED OUTLETS AND COVER OPENINGS WITH PLATES. bp, Y! 28100 TORCH PARKWAY WARRE)MLE, RUIM 60555 AY114 r MET d14WlZR and NI. Wr ACUT Y®v's Lend Lease 801 WARRDWILLF ROAD - SUITE 6000 LISLE. RLNOIS' c;. !I 5 -5206 q_ P" IRV cALM I; WCL O,t:F DE5TX'Aa,70V I t The w1pierd of thae mal.rWh underland: Poet copyright In IN rlM.ria4 1. om.d by BP, and olm, W Mt . matedah corddn KWWgad and confW.nfial buslnm Infomlation of OF. Accordingly, IN m1pteM ogress to Maki tMse materials in strict mnfld.nce and ag— not to dislm fi— malxkte I. any o1Mr porly mM I.M- agrm rot to mats mpi.a of th. material:. Th. —Ipknt agr to ua tM mat.d ' only for Po. limB.d purpoa for .hkh BP Ms mad. tM mat.dots onMbte, aru redpk l og— tu Mum all material. to BP s6hw upon cwplNiw of fM Intendod purpm or upon Ms mqual of BP, hiah..r coma nnl. 4200 BLDG. V.5 AmPm INTERIOR RETROFIT tmvrsf BP #35138 2500 S. FRENCH AVENUE SANFORD, FLORIDA SCNL AujoCY Z". 4&c'' N RfAlt 0EMED 0..' NBV l Alt 6FAMV Br FDA - FU NN - El-0_4200.DWGGMM` DUNK mz POWER PLAN BEFLd6 E.1.0 COPtttIGM ]car 8•A.YPnr A.