Loading...
14100 Plantation Lakes Cir BLDG 14 - 99-000772 (PLANTATION LAKES) (NEW APT BLDG) (A)ZONE CONTRACTOR PHONE # _ LOCATION OWNER _ ADDRESS o4 1 CO P L^%*4A4;&o SUBDIVISION: DATE zhq.T,e- PHONE #"ggw" / Y PLUMBING CONTRACTOR ADDRESS PHONE # IqPERMIT # l q r "7? LOT NO. f5lddi JOB BLOCK: *3mrSECTION: COST $ �JARE FEET: FEE $ MODEL: STATE NO. c;6zo OCCUPANCY CLASS: FEE $/� V ELECTRICAL CONTRACTOR 1FEE $ ADDRESS PHONE # MECHANICAL CONTRACTOR °� �� - FEE $ �� INSPECTIONS TYPE DATE OK REJECT BY ADDRESS PHONE # MISCELLANEOUS CONTRACTOR FEE $ z ENERGY SECT. ADDRESS SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS () FINISHED FLOOR ELEVATION REQUIREMENTS () CERTIFICATE OF OCCUPANCY ARCHITECTURAL APPROVAL DATE: ISSUED # DATE: FINAL DATE As LETTER Y M B 0 L L E G E N D #16/2 #14/2 COND. COND. SOLID, RED SOLID BLUE FP[,,. TYPE FPL TYPE Ld NOTIFICATION CIRCUIT 24VD(C' POWER CIRCUIT SYMBOL DESCRIPTION PART NUMBER SOLID RED OUTLET BOX FFAC FIRE ALARM CONTROL. PANEL (FACP) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY FAA FIRE ALARM SYSTEM ANNUM. (FAAP) SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING HORN/STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP 80" t(), ISTROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX IPI MANUAL STATION SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING SPRINKLER WATER FLOW swrrCH BY OTHERS (n FLEX TO DEVICE FROM J -BOX Cy C) SPRINKLER TAMPER SWITCH BY OTHERS FLEX TO DEVICE FROM J -BOX JUNCTION BOX V BY OTHERS < 4" SQUARE UNLESS NOTED 0 END -OF -LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY PHOTOELECTRIC SMOKE DET ECTOR/BASE SEE SPECIFICATION SHEET 4" OCTAGON ROOM MINI -HORN SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING LETTER W I R_ E � L DESCRIPTION E. G E N D "HARD WIRE" USE A 6 #16/2 #14/2 COND. COND. SOLID, RED SOLID BLUE FP[,,. TYPE FPL TYPE Ld NOTIFICATION CIRCUIT 24VD(C' POWER CIRCUIT D #18/2 COND. SOLID RED FPL TYPE < Q MANUAL -- INITIATION CIRCUIT E .... . . . ....... #18/2 COND. SOLID RED- FPL 'TYPE AUTOMATIC INITIATION CIRCUIT < Ir AIIN REVISIONS DAT E PERMIT SEG ................. 5-25-99 Q0 x W. 0 CC) F-- 0 C0 Ld hi > < Q 0 _j LtJ < Ir AIIN < OL Q0 x W. 0 CC) F-- 0 LL1 < OL C-) I. ---- (n Cy C) Cr) c� lh-, < C-] 0 < LL z < Ld (ZV) o M < CL DRAWN: SEC CHECKED: PAL DATE: 2-25-99 SCALE: 1 /8"-1 _ 0" JOB NO. SHEET FA BUILDING TYPE V I ST F -L. 1 OF 3 SHEETS REVISIONS 'SS Y M B 0 L L E G E N D "HARD WIRE" C-1) SYMBOL -j" DESCRIPTION PART NUMBER OUTLET BOX FACP FIRE ALARM CONTROL PANEL (FRCP) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY RED FIRE ALARM SYSTEM ANNUN. (FAAP) SEE SPECIFICATION #14/2 4" SQUARE w/51NGLE GANG RING SOLID HORN/STROBESEE FPL TYPE SPECIFICATION SHEET 4" SQUARE x -2-1f8" DEEP BOX (D STROBE SEE SPECIFICATION SHEET 4` SQUARE x 2-1/8" DEEP BOX JPJ MANUAL STATION 'SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG, RING E SPRINKLER WATER FLOW SWITCH BY OTHERS SOLID FLEX TO DEVICE FROM J -BOX FPL TYPE SPRINKLER TAMPER SWITCH BY OTHERS < ----------- FLEX TO DEVICE FROM J -BOX Eil JUNCTION BOX BY OTHERS Z_ 4" SQUARE UNLESS NOTED END -OF -LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY PHOTOELECTRIC SMOKE DETECTOR/BASE SEE SPECIFICATION SHEET 4" OCTAGON FROOM MINI -HORN SEE SPECIFICATION SHEET 4" SQUARE W/SINGLE GANG RING REVISIONS W I R E L, E G E N D "HARD WIRE" C-1) LLJ 00 DESCRIPTION L=,J) USE -LETTER A 1 #16/2 COND. SOLID RED FPL TYPE NOTIFICATION CIRCUIT B #14/2 COND. SOLID BLUE FPL TYPE 24VDC POWER CIRCUIT Li > <r- (D nrl D #1812 COND. SOLID RED FPL TYPE MANUAL -- INITIATION CIRCUIT E #18/2 COND. SOLID RED- FPL TYPE AUTOMATIC INITIATION CIRCUIT . .. . . .. . .. . .............. . . .. .. . ............ REVISIONS DATE PERMIT SEC 5-2-5-99 C-1) DRAWN: SEC CHECKED: PAL DATE: 2-25-99 SCALE: 'I /8"=1 ' ----0" JOB NO. SHEET FA BUILDING TYPE V 2ND FL. 2 OF SHEETS C-1) LLJ 00 L=,J) I-, V) Li > <r- (D nrl 0 0 j IJI_ Orl LL] - 7, (D __J x < < Q 0 LL_ _A __J < C0 Z_ LJ C0 0 Ld o <f - DRAWN: SEC CHECKED: PAL DATE: 2-25-99 SCALE: 'I /8"=1 ' ----0" JOB NO. SHEET FA BUILDING TYPE V 2ND FL. 2 OF SHEETS LLJ < n nrl 0 0 j IJI_ Orl LL] - 7, < Q 0 L _A __J < Z_ m 0 <f - DRAWN: SEC CHECKED: PAL DATE: 2-25-99 SCALE: 'I /8"=1 ' ----0" JOB NO. SHEET FA BUILDING TYPE V 2ND FL. 2 OF SHEETS F ivi B 0 L E N D W I SYMOOL F DESCRIPTION PA Ipr NUMBER OUTLET BOX ECfl I FIRE ALARM CONTROL PANEL- (FACID) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY = FIRE ALARM SYSTEM ANNUN. (FAAP) 'SEE SPECIFICATION SHEET 4 ", S 0 UAR E w/5INGLE GANG' RING -_ - --- I-IQRN/STROB_EE SEE S 5PECIFICATION SHEET .......... ... ---- --- -- 4" SQUARE x 2 --1/8" DEEP BOX SOLID STROOE SEE SPEC"IFICATiON SHEET 4" "S(,)UARE x 2-1/8" DEFP BOX MANUAL STATION SEE SPECIFICATION SHEET 4" SQUARE w/13INGLE GANG RING BLUE SPRINKLER WATER FLOW SWITCH BY oTHERS FLEX TO DEVICE FROM J --BOX #18/2 SPRINKLER TAMPER SWITCH BY OTHERS ------------- FLEX TO DEVICE FROM J --BOX FPL TYPE JUNCTION BOX BY OTHERS 4" SQUARE UNLESS NOTED COND. END -OF -LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY AUTOMATIC INITIATION cimcurr HOTOELECTRIC SMOKE DET'[:-C'FOR/BA$[:-* SEE SPECIFICATION SHEET 4" OCTAGON 17 -- f) ROOM MINI --HORN SEE SPECIFICATION SHEET 4" SQUAR17 w/SIN(.-,LE GANG RING \\I REVISIONS - .- qF PERMIT W I R E L E G E_ N D "HARD WIRE--) LETTER USE A ____DESCRIPTION #16/2 COND. SOLID RED FPL TYPE NOTIFICATION CIRCUIT #14/2 COND. SOLID BLUE FPL TYPE 24VDC POWER CIRCUIT 0 #18/2 COND. SOLID RED FPL TYPE MANUAL .-- INITIATION CIRCUIT F #18/2 COND. SOLID FRED— FPL TYPE . . .... .......... AUTOMATIC INITIATION cimcurr V) (D 17 -- f) Lei 0- 00 \\I REVISIONS - .- qF PERMIT N- DATE 5 15-{a9 _�q 5 - 2- 5 �-9 9 ("0 Li Lo - uz 00 t7 rN Qo D cn Ia Ld <c 0 < ()` 0 CF C -)x i < __j a- < w--) V) (D 17 -- f) Lei 0- 00 / V) CK cp cl\I '0 < < LL, 0 M ("0 Li < n < < __j a- < w--) V) f F, -( 17 -- f) w0 __j / V) '0 < < LL, 0 M �r DRAWN: SEC CHECKED: PAL DATE: 5-25-99 SCALE: 1/8"=I' -O" JOB NO. SHEE f FA BUILDING TYPE_ V 3RD FL. 3 OF SHEETS NOTE ALL STEEL PIPE AND FITTINGS TO BE GALVANIZED. ALL STEEL PIPE AND FITTINGS TO BE WRAPPED & COATED. 4- 015r - 9q'vol 9 F� CF Fp J UG2 r1p .. lb 9J - BUILDING - UNDERGROUND GENERAL NOTES: 1. ALL MATERIAL AND INSTALLATION TO BE IN ACCORDANCE WITH NFPA 24 AND THE CITY OF SANFORD. 2• Q~ 2. ALL JOINTS TO BE RESTRAINED IN ACCORDANCE WITH NFPA 24, AND THE CITY CPUC As OF SANFORD. (BY DELTA) 3. ALL PIPING TO HAVE A 36" MINIMUM DEPTH OF BURY FROM TOP OF PIPE. 4. ALL PIPING TO BE HYDROSTATICALLY TESTED AND FLUSHED IN ACCORDANCE WITH NFPA 24 AND THE CITY OF SANFORD. :XTERIOR WALL TO DOMESTIC WATER TYPICAL APARTMENT BLDG. LEAD-IN DETAIL 'T() ��g B FLOW TEST DATA DESIGN CRITERIA STATIC 65 SYSTEM NO. LOCATION RESIDUAL 50 HAZARD TYPE OF SYSTEM FLOW 1135 SPACING NO. OF SPRINKLERS DATE 4-25-99 K FACTOR DENSITY TIME : 3:45 INSIDE HOSE DESIGN AREA LOC. : CITY MAIN OUTSIDE HOSE GPM FLOW @ BR2 BY D.F.S. I RACK GPM IRESIDUAL PSI @BR2 SITE FIRE PROTECTION PLAN HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND SYMBOLS I QUAN. I SIZE I TEMP. I MAKE I MODEL I TYPE FINISH I" = 60'-0 MATERIALS I NO. DATE ESC. I SIZE LOCATION TYPE I 1 4-1-99 OPER�Y �,NE REVISION DESCRIPTION BY DELTA FIRE GENERAL CONTRACTOR SUBMITTAL FJL (Ut1U} SPRINKLERS INC. 111 TECH DRIVE SANFORD, FLORIDA 32771 DRAWN BY: F. LUPO DATE: 4-1-99 SPRKS. ON JOB: 2,808 SCALE: AS NOTED UNDERWRITERS: LOCAL AUTHORITY CONTRACT NO. A1907 -------------------------- I q PLANTATION LAKES APARTMENTS SANFORD FLORIDA DCC CONSTRUCTORS INC. 355 SOUTH C.R. 427 LONGWOOD, FL. 32750 CUSTOMER PROJECT NO. I SHEET NO. _-1_- OF _____ BUILDING TYPE 5- 2ND FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/8" = 1'=0 BUILDING TYPE 5- 1ST FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/S" = 1'-0 GENERAL NOTES: I. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA 13R, 1996 EDITION, AND THE LOCAL AUTHORITY. 2. ALL MATERIAL AND DEVICES TO BE IN ACCORDANCE WITH NFPA 13 & 13R 1996 EDITION. 3. ALL PIPE AND FITTINGS TO BE CPVC, EXCEPT FOR THE BUILDING RISER, WHICH WILL BE SCH. 40 BLACK STEEL 4. ALL RESIDENTIAL SPRINKLER HEAD SPACING TO CONFORM WITH THE MAN- UFACTURERS LISTING. 5. ALL FIREWALL PENETRATIONS TO BE SEALED IN ACCORDANCE WITH THEIR RATING. 6. SPRINKLERS SHALL BE OMITTED IN THE FOLLOWING AREAS, PER NFPA 13R, 1996 EDITION, SECTION 2-6 EXCEPTIONS 1 THRU 4 - CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES UNDER 24 SQ. FT., PORCHES, BALCONIES, CORRIDORS, AND STAIRS WHICH ARE OPEN AND ATTACHED, AND ALL OTHER AREAS NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGE. NOTE: ALL PIPE SIZES ARE 3/4" UNLESS NOTED OTHERWISE, ROOM LEGEND A[] - LIVING ROOM Q - BEDROOM T] - KITCHEN FM - CLOSET M - UTILITY 0 - DINING ROOM © - PORCH ❑H - H. V. A. C. n - BATHROOM [Q - STORAGE []M - ENTRY 0 - HALLWAY 6' 120V. ELECTRIC BELL @r SPARE HEAD BOX W/ WRENCH GLOBE VA. ----_ __ I' INS. TEST & DRAIN FROM SUPPLY TO SYSTEM PRESSURE GAUGE FLOW SWITCH (WIRED BY OTHERS) I ACCESS PANEL 30' X 20' 0 -d Iz RES�UCU�sA�- FOe 0-C)WQ. 2WATTS 0070T DOUBLE CHECK VALVE ASSY, 2' B.BALL BFV. W/ T.S. (WIRED BY OTHERS) PRESSURE GAUGE TYPICAL BLDG. RISER DETAIL Mir u" r Taco ;PVC N. T. S. TUk% '-COLE TOLCO PVC HANGER DETAIL N. T. S. ■ NOTE: CW_ DECK SHOWK HOWEVER; THESE TABLES APPLY FOR ANY TYPE OF CONST. SEE 1 HANGER SPACING LEGEND i BRACE/HANGER N. T. S. vlhtis CITY ®F SA E0 ► t3,d REQUIRED FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA FIRE STATIC 65 SYSTEM NO. D/A #7 D/A 8 D/A #9 LOCATION D/A #7 D/A #8 D/A #9 SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS RESIDUAL 50 HAZARD LIGHT LIGHT ORD. TYPE OF SYSTEM WET WET WET 324 1/2' 155' GLOBE JN -LF PEND WHITE SEMI-REC. 1*,-%, B. LINES/MAIN CPVC ,IIIZZZSJj SPRINKLERS INC. FLOW 1135 SPACING 2Ox20 2Ox20 130 NO. OF SPRINKLERS 1 4 4 .4 1/2' 155' GLOBE JN -LF RES/HSI,4 WHITE SEMI-REC. 11�' RISER SCH 40 111 TECH DRIVE SANFORD, FLORIDA 32771 SANFORD FLORIDA DATE 4-25-99 K FACTOR 2.8 2.8 5.6 DENSITY .10 .10 .15 ® 1/2' 1 155' GLOBE JN STD/PEND WHITE SEMI-REC. 2' UNDERGROUND CPVC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME 3:45 INSIDE HOSE 45 45 45 DESIGN AREA I HD 4 HDS ENTIRE SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. CITY MAIN OUTSIDE HOSE 0 0 0 GPM FLOW e BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY : D.F.S. RACK GPM 0 0 0 RESIDUAL PSI 2 BRI CONTRACT NO, A1907 CUSTOMER PROJECT NO. SHEET NO. OF TABLE 1 TABLE 2 MAXIMUM SUPPORT SPACING MAXIMUM SUPPORT SPACING FROM END LINE HEAD FROM INLINE HEAD TABLE 3 MAXIMUM SUPPORT SPACING BETWEEN-AWjERS PIPE SIZE THAN LESS THANMORE THAN LESS THAN roopsi 100 PSI 00 PSI 100 PSI ANY PSI 3/4' 0'-9' '-6' 4'-0' '-0' 5'-6' i' 0'-12' -9 5'-0' - 6'-0' 1-1/4' 0'-16' 0' ' 6'-0' 5v 6'-6' 1-1/2• 0'-24• 7'-0' 3(-k7'-0' 2' 0'-24' 0'-12 7'-0' -0' 21/2' 0'-24' 0'-12' 7'-0' 7'-0' 9'-o' 3' 0'-24• 0'-12' 7'-0' 7'-0' 10'-0' ■ NOTE: CW_ DECK SHOWK HOWEVER; THESE TABLES APPLY FOR ANY TYPE OF CONST. SEE 1 HANGER SPACING LEGEND i BRACE/HANGER N. T. S. vlhtis CITY ®F SA E0 ► t3,d REQUIRED FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA FIRE STATIC 65 SYSTEM NO. D/A #7 D/A 8 D/A #9 LOCATION D/A #7 D/A #8 D/A #9 SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS RESIDUAL 50 HAZARD LIGHT LIGHT ORD. TYPE OF SYSTEM WET WET WET 324 1/2' 155' GLOBE JN -LF PEND WHITE SEMI-REC. 1*,-%, B. LINES/MAIN CPVC ,IIIZZZSJj SPRINKLERS INC. FLOW 1135 SPACING 2Ox20 2Ox20 130 NO. OF SPRINKLERS 1 4 4 .4 1/2' 155' GLOBE JN -LF RES/HSI,4 WHITE SEMI-REC. 11�' RISER SCH 40 111 TECH DRIVE SANFORD, FLORIDA 32771 SANFORD FLORIDA DATE 4-25-99 K FACTOR 2.8 2.8 5.6 DENSITY .10 .10 .15 ® 1/2' 1 155' GLOBE JN STD/PEND WHITE SEMI-REC. 2' UNDERGROUND CPVC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME 3:45 INSIDE HOSE 45 45 45 DESIGN AREA I HD 4 HDS ENTIRE SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. CITY MAIN OUTSIDE HOSE 0 0 0 GPM FLOW e BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY : D.F.S. RACK GPM 0 0 0 RESIDUAL PSI 2 BRI CONTRACT NO, A1907 CUSTOMER PROJECT NO. SHEET NO. OF 4 rill) 4Ux" 1 MAI) eUVU BUILDING TYPE 1- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 3,7,8,16, & 17 1/8" = 1'-0 4 HDS 20x20 1 HEAD 20x20 BUILDING TYPE 3- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 1,4,5,9,10,12,13 & 15 1/8n = 1'-0 1 HEAD 20x20 4 HDS 20x2O BUILDING TYPE 5- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/8" = l'-0 V am Ail. PIPE SIZES ARE 3/4" UNLESS NOTED OVERMISE. ROOM LEGEND ® - LIVING ROOM nBB - BEDROOM CD - KITCHEN 0 - CLOSET - UTILITY - DINING ROOM © - PORCH N - H. V. A. C. ® - BATHROOM OL - STORAGE ® - ENTRY n - HALLWAY 4 FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTASTATIC FIRE SPRINKLERS INC. 111 TECH DRIVE SANFO D, FIARIDA 32771 65 SYSTEM NO. BLDG. TYPE I BLDG, TYPE 3 BLDG. TYPE 5 LOCATION BLDG. TYPE 1 BLDG. TYPE 3 BLDG. TYPE 5 SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS SANFORD FLORIDA RESIDUAL : 50 HAZARD SEE SHEET SEE SHEET SEE SHEET TYPE OF SYSTEM SEE SHEET SEE SHEET SEE SHEET �i 324 1/2' 155' GLOBE JN—LF RES/PEND WHITE SEMI—REC. 1'— B. LINES/MAIN CPVC FLOW : 1135 SPACING 2 OF 5 4 OF 5 5 OF 5 NO. OF SPRINKLERS 2 OF 5 4 OF 5 5 OF 5 , 1/2' 155" GLOBE JN—LF RES/HSW WHITE SEMI—REC. 1ST' RISER SCH 40 DATE : 4-25-99 IBY K FACTOR DENSITY 2' UNDERGROUND CPVC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME : 3:45 INSIDE HOSE DESIGN AREA SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. : CITY MAIN OUTSIDE HOSE GPM FLOW @ BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 : D.F.S. RACK GPM RESIDUAL PSI @ BRI CONTRACT NO. A1907 CUSTOMER PROJECT NO. -5- I SHEET NO. —_3-- OF --5--