Loading...
6100 Plantation Lakes Cir - 99-000770 (PLANTATION LAKES) (NEW APARTMENT BLDG) (A)ZONE CONTRACTOR ADDRESS PHONE # LOCATIOP OWNER ADDRESS PHONE #'• PLUMBING CONTRACTOR u I til �v�Vv� ADDRESS PHONE # ELECTRICAL CONTRACTOR ADDRESS PHONE # MECHANICAL CONTRACTOR ADDRESS�- PHONE # MISCELLANEOUS CONTRACTOR ADDRESS 00 'OP L ftri 4a4 4-7 d*coic te... DATE��/� SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS (�_) FINISHED FLOOR ELEVATION REQUIREMENTS �) ARCHITECTURAL APPROVAL DATE: SUBDIVISION: P31 cl q (P PERMIT. # 9!j LOT NO. "I JOB COS' FEE STATE NO. CG COVO 8 /0 FEE $ 1 Tb q FEE $ -71 'J FEE $ �n BMW: SECTION: SQUARE FEET: MODEL: OCCUPANCY CLASS: L INSPECTIONS r --TYPE DATE OKr-REJECT BY FEE $ ENERGY SECT. qq-L�t h --t49 /�/ re CERTIFICATE OF OCCUPANCY ISSUED # _ DATE: FINAL DATE EPI: Y M B 0 L L E G E N D , SYMBOL DESCRIPTION PART NUMBER OUTLET BOX [FACd FIRE ALARM CONTROL. PANEL (FRCP) SEE SPECIFICATION SHEET PROVIDED BY ALERT 'SECURITY FAA FIRE ALARM SYSTEM ANNUM. (FAAP) SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING FPL — FPL HORN/STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX D . STROBE . . .................. - --- --------- - SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX I -pi MANUAL STATION SEE SPECIFICATION SHEET 41' SQUARE w/SINGLE GANG RING 4, SPRINKLER WATER FLOW :;WITCH BY OTHERS FLEX TO DEVICE FROM J -BOX SOLID SPRINKLER TAMPER $WITCH BY OTHERS FLEX TO DEVICE FROM J -BOX JE JUNCTION E30X BY OTHERS 4" SQUARE UNLESS NOTED Li l END -OF -LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY Ea PHOTOELECTRIC SMOKE DETECTOR/BASE SEE SPECIFICATION SHEET 4" OCTAGON D4_1, ROOM MINI HORN SEE SPFC]FICATION ,HEFT r 4" SQUARE w/SINGLE GANG RING LETTER W 1 R E L DESCRIPTION E E E N D "HARD WIRE" USE A B #1 5/2 #14/2 COND. COND. SOLID SOLID RED — r_ BLUE —BLUE FPL — FPL TYPE TYPE L0 zltz NOTIFICATION CIRCUIT 24VDr, POWER CIRCUIT "I D #18/2 COND. SOLID RED — FPL TYPE MANUAL — INITIATION CIRCUIT E #18/2 COND. SOLID RED— FPL 'TYPE FF 0 AUTOMATIC INITIATION CIRCUIT < (D < Li l Ld < 0) r 010*1N I T F-LOOR REVISIONS GATE D R AW N: SEC CHECKED: PAL DATE: 2-25-99 SCALE: JOB NO. SHEET FA BUILDING TYPE V 'I ST FL. OF SHEETS L0 zltz co 0-d (o Ld Qo > < 0 �T ch E 0 FF 0 x < (D < Li l Ld < 0) r 010*1N 0 CL 00 < CD C5 rK 0 (D -A- < Ly - M 0 D R AW N: SEC CHECKED: PAL DATE: 2-25-99 SCALE: JOB NO. SHEET FA BUILDING TYPE V 'I ST FL. OF SHEETS ch (D < < Li l g (J� < C5 rK <1 (D < < Ly - M 0 D R AW N: SEC CHECKED: PAL DATE: 2-25-99 SCALE: JOB NO. SHEET FA BUILDING TYPE V 'I ST FL. OF SHEETS S Y fel B 0 L L E G E N D SYMBOL DESCRIPTION PART NUMBER OUTLET BOX FACP FIRE ALARM CONTROL PANEL. (FACP) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY I FAA FIRE ALARM SYSTEM ANNUM. (FAAP) SEE SPECIFICATION SHEET Q" SQUARE w/SINGLE GANG RING o f HORN/STROBE ------------- SEE SPECIFICATION! SHEET 4" SQUARE x 2-1/8" CHEEP BOX l'o STROBE SEE SPECIFI CATION SHEET 4" SQUARE x 2-1/8" DEEP BOX, U MANUAL STATION — SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE (;,ANG RING —^ 24VDC POWER CIRCUIT MANUAL _ INITIATION CIRCUIT SPRINKLER WATER FLOW SWITCH BY OTHERS FLEX TO DEVICE FROM J—BOX SOLID SPRINKLER TAMPER SWITCH BY OTHERS ��. FLEX TO DEVICE FROM J—BOX 1 JUNCTION BOX BY OTHERS 4" SQUARE UNLESS NOTED mm— Y.— END—OF--LINE DEVICE ��^ SEE SPECIFICATION! SHEET PROVIDED BY ALERT SECURITY �8 PHOTOELECTRIC SMOKE DETECTOR/BASE `.SEE SPECIFICATION SHEET 4" OCTAGON sE ROOM MINI—HORN SEE SPECIFICATION SHEET 4° SQUARE w/SINGLE GANG RING LETTER W I R E I DESCRIPTION E G E N D "HARD WIRE" USE A #16/2 COND. SOLID RED - FPL TYPE NOTIFICATION CIRCUIT B D #14/2 ,'t S/2 GOND, GOND. SOLID SOLID BLUE RED - FPL TYPE FPL TYPE Lh".i`1_. 24VDC POWER CIRCUIT MANUAL _ INITIATION CIRCUIT E #18/2 COND. SOLID RED--- FPL TYPE 1 AUTOMATIC INITIATION CIRCUIT 2ND FLOOR LJ . ..... REVISIONS i DATE PERMITISEC 5-25-99 DRAWN: SEC ` CHECKED: PAL I DATE: 2-25-99 SCALE: JOB NO. E SHEET FA E BUILDING TYPE V 2ND FL. � I 2 OF 3 SHEETS I I I L! ! Q0 I C\! Lo c-) 00 Q0 t Lh".i`1_. N I ) tet" QD CC co < Wt� 1 �L �:D Ci o x i 0 (D Q �� LiJ --1 00 i LLJ I✓--- ? tD C\!F Z' �. -- Com? It 5 M Lul L' DRAWN: SEC ` CHECKED: PAL I DATE: 2-25-99 SCALE: JOB NO. E SHEET FA E BUILDING TYPE V 2ND FL. � I 2 OF 3 SHEETS I L! ! CC < �L Q ( < < c (D W �� l --1 Q cy Com? � 5 M Lul L' DRAWN: SEC ` CHECKED: PAL I DATE: 2-25-99 SCALE: JOB NO. E SHEET FA E BUILDING TYPE V 2ND FL. � I 2 OF 3 SHEETS `� Y fvi B 0 L EI G E N D SYMOOL DESORIPTION. PART NUMBER OUTLET BOX FRCP FIRE ALARM CONTROL. PANEL (FACP) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY FAA FIRE ALARM SYSTEM ANNUM. (FAAP) SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING BLUE RED - HORN/ STROBE- - - SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX to STRODE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/3" DEEP BOX u MANUAL STATION SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING L.d 1- SPRINKLER WATER FLOW SWITCH BY OTHERS FLEX TO DEVICE FROM J --BOX ::D SPRINKLER TAMPER SWITCH BY OTHERS �^^ � FLEX TO DEVICE FROM J -BOX �r L?1 JUNC'TION BOX BY OTHERS 4" 501JARE UNLESS NOTED END -OF -LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURIT`f 2 PHOTOELECTRIC SMOKE DETECTOR/BASE SEE SPECIFICATION SHEET 4" OCTAGON ,ta ROOM MINI ---HORN SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING LL- LETTER A W I #16/2 R El L DESCRIPTION COND. SOLID RED E G E_ N FPL. TYPE D "HARD W I R EL" USE NOTIFICATION CIRCUIT m 0 U�^^ #14/2 # 18/2 COND. COND. SOLID SOLID BLUE RED - — FPL TYPE FPL TYPE - 24VDC POWER CIRCUIT MANUAL -- INITIATION CIRCUIT E #18/2 COND. SOLID RED- FPL TYPE � � AUTOMATIC INITIATION CIRCUIT L.d 1- IN Q0 C� ::D < L_J' I.�\ `. �� EREVISION:SDATE 5-25- 9 U) Awl W Q0 r1--.1 c�cJ C0 pwo L.d 1- IN Q0 C� ::D < n C� J < <�� _o l L_ z Ld `< (D LSI C c U) (D ? Co _J CD C\I 0 cD < ,7 0 < Li ! m U) W C� < n < <�� _o < w LSI C (D U) _J I- cD < ,7 0 < Li ! m L_l_._ DRA`NN: SEC CHECKED: PAL_ DATE: 5-25-99 SCALE: 1/8"= 1 ' JOB NO. SHEET FA BUILDING TYPE V ?RD FI. 3 OF 3 SHEETS NOTE ALL STEEL PIPE AND FITTINGS TO BE GALVANIZED. ALL STEEL PIPE AND FITTINGS TO BE WRAPPED & COATED. XTERIOR WALL TO DOMESTIC WATER TYPICAL APARTMENT BLDG. LEAD-IN DETAIL � zo0�B0v OPER�Y 00E -------- ---- ------------- --------------------------- ---------------- ------- ---- ---.------------------- ---------- ---------------------------- ---------------- -------- ------------------- --------------- --------------- --------- -------- -------- --------------- ----------- --------.---.- - ..__._..--------------- .----.------ ----- ---------__.-------.---- ------.---------- ------------- -------------- ------------ --------------------- ----------------------- ---- -------------------------- ---------------------------- ------------------- ------- --------------- ---- ----- --------------------------- -- A� ':5::.'. ': )b::; .: .iJi.....::::� ...iA<:• ..'«r: .<'�.;?�'� ^::: ?v �'•v5`:.. <fi: :.9?:i`?E. ... .. .t. :. q:. ..yi. ..r. .. �: .,.. .�.. 'f :<.• :Y<:'.:.r: r:..<:<,.•.+,� :....:'ff ::i ':Y : .. '-{ .«"?:K::. :: L^ ...': K:?:: t`9.:'9IF 2:::;G:?:zt: r ... ...... .. ...t,.. .:A .::?::. rR r:?L`. Sf t7t:::S?.:yb:.'.`T. ... .h ....:fR::?5::; . ...f .. .. ., ,' <... 9f�..3 > , .7.... s..?:. -:7 .. : - -ri- :.:::<aracZ' �?xz .... >rY �:..✓:?r.• :'x,:. :x"s.w ;:g;:: g<r .� :;y. 's.. SITE FIRE PROTECTION PLAN I" = 60'-0 f FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS �. < DATE REVISION DESCRIPTION -ti-GC�i �'•4- TATIC : 65 SYSTEM NO. • C .d CyTp pG `L� q�9O L - BUILDING - UNDERGROUND GENERAL NOTES: p�r��'en��� � I. ALL MATERIAL AND INSTALLATION TO BE IN ACCORDANCE WITH NFPA 24 AND UG2 ��'RJJ��9��9�`�9J uci MAKE THE CITY OF SANFORD. TYPE 4 2 ��5�� 2. ALL JOINTS TO BE RESTRAINED IN ACCORDANCE WITH NFPA 24, AND THE CITY LOCATION PVC (BY OTHERS) CPVC (BY DELTA) AS OF SANFORD. 3. ALL PIPING TO HAVE A 36" MINIMUM DEPTH OF BURY FROM TOP OF PIPE. GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS SANFORD FLORIDA 4. ALL PIPING TO BE HYDROSTATICALLY TESTED AND FLUSHED IN ACCORDANCE HAZARD QHS c WITH NFPA 24 AND THE CITY OF SANFORD. XTERIOR WALL TO DOMESTIC WATER TYPICAL APARTMENT BLDG. LEAD-IN DETAIL � zo0�B0v OPER�Y 00E -------- ---- ------------- --------------------------- ---------------- ------- ---- ---.------------------- ---------- ---------------------------- ---------------- -------- ------------------- --------------- --------------- --------- -------- -------- --------------- ----------- --------.---.- - ..__._..--------------- .----.------ ----- ---------__.-------.---- ------.---------- ------------- -------------- ------------ --------------------- ----------------------- ---- -------------------------- ---------------------------- ------------------- ------- --------------- ---- ----- --------------------------- -- A� ':5::.'. ': )b::; .: .iJi.....::::� ...iA<:• ..'«r: .<'�.;?�'� ^::: ?v �'•v5`:.. <fi: :.9?:i`?E. ... .. .t. :. q:. ..yi. ..r. .. �: .,.. .�.. 'f :<.• :Y<:'.:.r: r:..<:<,.•.+,� :....:'ff ::i ':Y : .. '-{ .«"?:K::. :: L^ ...': K:?:: t`9.:'9IF 2:::;G:?:zt: r ... ...... .. ...t,.. .:A .::?::. rR r:?L`. Sf t7t:::S?.:yb:.'.`T. ... .h ....:fR::?5::; . ...f .. .. ., ,' <... 9f�..3 > , .7.... s..?:. -:7 .. : - -ri- :.:::<aracZ' �?xz .... >rY �:..✓:?r.• :'x,:. :x"s.w ;:g;:: g<r .� :;y. 's.. SITE FIRE PROTECTION PLAN I" = 60'-0 f FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA F Q SPRINKLERS INC. 111 `TECH DRIVE SANFORD, FLORIDA 32771 TATIC : 65 SYSTEM NO. LOCATION SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ` ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS SANFORD FLORIDA ESIDUAL 50 HAZARD TYPE OF SYSTEM FLOW 1135 SPACING NO. OF SPRINKLERS DATE 4-25-99 K FACTOR DENSITY DRAWN BY: F. LUPO DATE 4-1-99 DCC CONSTRUCTORS INC. TIME : 3:45 INSIDE HOSE DESIGN AREA SPRKS. ON JOB. 2,808 SCALE, AS NOTED 355 SOUTH C.R. 427 LOC. : CITY MAIN OUTSIDE HOSE GPM FLOW e BR2 UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY : D.F.S. RACK GPM RESIDUAL PSI 2 BR2 CONTRACT NO. A1907 CUSTOMER PROJECT NO. SHEET NO. --1_- OF _____ , � GENERAL NOTES: ® 0 I. ALL WORK SHALL BE DONE IN ACCORDANCE WITH NFPA 13R, 1996 EDITION, ©UP F AND THE LOCAL AUTHORITY. 2. ALL MATERIAL AND DEVICES TO BE IN ACCORDANCE WITH NFPA 13 & 13R ❑ 1996 EDITION. 3. ALL PIPE AND FITTINGS TO BE CPVC, EXCEPT FOR THE BUILDING RISER, A ° A ° � WHICH WILL BE SCH. 40 BLACK STEEL ❑ A. 4 ° i� UP C ` ` ALL RESIDENTIAL SPRINKLER HEAD SPACING TO CONFORM WITH THE MAN- UFACTURERs LISTING. UP �� EO ® A 5. ALL FIREWALLPENETRATIONS TO BE SEALED IN ACCORDANCE WITH THEIR D ❑ 4G © 6. SPRINKLERS SHALL BE OMITTED IN THE FOLLOWING AREAS, PER NFPA 13R, 1996 EDITION, SECTION 2-6 EXCEPTIONS 1 THRU 4 - - B ❑ _ - - J ® °' CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES UNDER 24 DATTACHED, SQ. FT., PORCHES, BALCONIES, CORRIDORS, AND STAIRS WHICH ARE OPEN AND I a AND ALL OTHER AREAS NOT USED OR INTENDED FOR LIVING C PURPOSES OR STORAGE. 0 (D 4L C5 rDl i, nn L;�J � i' ;7 ❑ ❑ ,] �� i •' ❑D 0 � � ❑C \' ❑ I• t' 1' 1• 1• 1' 1• l' 1' t' t' ALL PIPE SIZES ARE 3/4" UNLESS NOTED OTHERWISE 10-3 19- - - - 5-0 - - - I- 5A L_ I L— ©© a -0 / I ©+�Tll OF CA&NETS AT JB' C. f. F AEON11T. CAB. 36' A.F.. / a ® O ROOM LEGEND F DI ❑ ❑j ❑ ® ❑ F ❑ Q - LIVING ROOM - BEDROOM E o 10 © ❑ - KITCHEN � Q oo� � J ❑ � � ^ �y� ; ❑D -CLOSET ® i nD FBI ❑E - UTILITY C 1 —AFF] ❑F F - DINING ROOM ILI UP DOw7 3�� A. UP G❑ -PORCH D A ° G 0 C.5 A. 4 _ -- - i An f Q- BATHROOM �/❑ I UP ° L❑ - STORAGE ° ° G❑® 0 - ENTRY HALLWAY xbWg5-2 ° 6' 120V, ELECTRIC BELL TO SYSTEM BUILDING TYPE 5— 2ND FLOOR FIRE PROTECTION PLAN SPARE HEAD TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/8n = 1'=0 Bax W/ WRENCH PRESSURE GAUGE FLOW SWITCH (WIRED BY OTHERS) GLOBE VA. --� I ACCESS PANEL 30' x 20' 1'12- '1z2' 2'WATTS 0070T DOUBLE CHECK VALVE ASSY. 2' B.BALL BFV. W/ T.S. (WIRED BY OTHERS) UP PRESSURE GAUGE ® An V INS. TEST & DRAIN [-G] UP C . 5 - © FROM SUPPLY A.4© GAn ❑ ® TYPICAL BLDG. RISER DETAIL J J .4G ® D ® N.T.S. ® 4 — — w O - —� �_ a s ° © E C ❑ ~ © �:I ✓; �� ONE HOLE TOLCO TWO HOLE TOLCO FOR C7 ,, ° 1 CPVC FOR CPVC r- ® 0 ' 0 Q- d 1 ,, 1!¢ lY�• 1�t• 1 1 1 lig 1 1 1 — ' ® O 1[ 3 1 19-9 — - 1-t0 -11 2- - © _]I�• _ 7A go O C8 C9 u 1 - ❑ 1' 24 7-I1 Y3 5 � � 5❑ o C V _ '- -we I' 1 it _ O =ffl:d 10 2-9 -10 PT N HANGER DETAIL o 22 B ❑ N.T.S. CIO ❑ N N A `-r /I ® ( - i `�-' © ® n, oma'. TABLE 1 TABLE 2 TABLE 3 MAXIMUM SUPPORT SPACING MAXIMUM SUPPORT SPACING MAX]" SUPPORT SPACING FROM END LINE HEAD FROM INLINE HEAD BETWEEN HANGERS ❑ ❑ PIPE LESS THAN MORE THAN LESS THAN MRE THAN SIZE 100 PSI 00 PSI 100 PSI 00 PSi ANY PSI UP C,'t' 3/4' 0'-9' 0'-6' 4'-0' '-0' 5'-6' i' 0'-12' -9 5'-0' 6'-0' - 2 � ,� 1-1/4' W-16' 0' 6'-0' S 6'-6' ° 6-5 1-i/2' 0'-24'7'-0' - 7'-0' -- — 2' 0-24' 0, - 1^ 7'-0' '-0' 8'-0' ❑ ❑ 21/2' 1 0'-24' 0'-12' 7-0' 7'-0' 91-V 0'-24' 0'-12' 7'-0' 7'-0' SPRINKLER RISER LOC. WITH SINGLE 1.5 FDC ° °31 ® ■ NOTE, CONC. DECK SHOWN. HOWEvERs THESE TABLES APPLY FOR ANY TYPE OF CONST. ` + DESIGN AREA #9 SEE TABLE I � SEE TABLE 3 SEE TABLE 2 SEE TABLE 3 SE.E�\ 2 \`-BRACE/HANGER BRACE /HANGER BRACE /HANGER 4 HDS SEE SITE PLAN FOR CONTINUATION BUILDING TYPE 5— 1ST FLOOR FIRE PROTECTION PLAN V HANGER SPACING LEG i :- TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/8" = 1'-0 / acoj V� FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA F NO. D/A #7 D/A 8 D/A #9 D/A #7 D/A #8 D/A #9 SYMBOLS QUAN. SIZE TEMP. TYPE SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL STATIC : 65 SYSTEM LOCATION MAKE MODEL FINISH ESC. FJL PLANTATION LAKES APARTMENTS RESIDUAL : 50 HAZARD LIGHT LIGHT ORD. TYPE OF SYSTEM WET WET WET 324 1/2' 155' GLOBE JN -LF PEND WHITE SEMI-REC. 1ST' -Ii' B. LINES/MAIN CPVC SPRINKLERS INC. 111 TECH DRIVE SANFORD, FLORIDA 32771 SANFORD FLORIDA FLOW 1135 SPACING 20x20 20x20 130 NO. OF SPRINKLERS 1 4 4 .4 1/2' 155' GLOBE JN -LF RES/HSvj WHITE SEMI-REC. 1ST' RISER SCH 40 DATE 4-25-99 K FACTOR 2.8 2.8 5.6 DENSITY .10 .10 .15 ® 1/2' 155' GLOBE JN STD/PEND WHITE SEMI-REC. 2' UNDERGROUND CPVC DRAWN BY; F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME 3:45 INSIDE HOSE 45 45 45 DESIGN AREA I HD 4 HDS ENTIRE SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. CITY MAIN OUTSIDE HOSE 0 0 0 GPM FLOW e BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY D.F.S. RACK GPM 0 0 0 RESIDUAL PSI e BRI CONTRACT NO. A1907 CUSTOMER PROJECT NO. SHEET NO. --5-- OF __ _ FG1 I D ❑I I FBI- = UP A ❑ UP A ❑ f– I I IInA 5 ® ; CJ® i®J I C 4 ® ® �► I4 B D o i I ❑D 444 MT D.2 D.2 C� CJ (C2)Fc] �3 C � ® 0 C a�CD7_ �(Fj N i D J w C i El ,a ,s F ; F nc FE] w CI i a Up R r[LP LDo Q �7j® T1 o d�lp � © © 0 J t it J 0 0 Q Ilo �II J 0 F- 1 �f y" r— ® 0 Q I o o © . ,, �� I o , o o O --- © FA - I O D up DESIGN AREA #8 DESIGN AREA #7 — 4 HDS 20x20 1 HEAD 20x20 DESIGN AREA #4 DESIGN AREA #5 4 HDS 20x20 1 HEAD 20x20 BUILDING TYPE 1- 3RD FLOOR FIRE PROTECTION PLAN BUILDING TYPE 3- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 3,7,8,16, & 17 1/8" = 1'-0 TYPICAL FOR BLDG. #'S 1,4,5,9,10,12,13 & 15 1/8n = 1'-0 UP u � ❑ ❑ ILA,I G ❑ UP ./ r �� A, 4 ®I I ® G D ® C. R o a o A, ,�� ® I NOTE: All PIPE SIZES ARE 3/4" UNLESS NOTED OTHERWISE ® C E O C I EOD °nl� ROOM LEGEND c, –a '' ! _'---�–� �� % o ,� F ❑A –LIVING ROOM 1' � 7 '-'s❑ ,• 77 1' F ,. ,. 1' 1.� 1� .h I , �� �1, � � � �� � �: � J ❑ B – BEDROOM ❑ - -0 5- lo( 19-9 _ I-10 5-0 0- - 5- e - - 2A -2� - ®- 1, 1�Fc] 1� - {� 1' -4 1 I ❑ -5 E C7 1' � ( © –KITCHEN FD]O C J —1 F s ❑ 0 r– I ❑E ® o CLOSET E – UTILITY L-`E�A D 0 Jt� 0 © ® ' , 0 F – DINING ROOM j ! © PORCH © E \ 2 — ❑ ❑H – H. V. A. C. BATHROOM \ ® 0 ` u ," �d,, ���������_ �',�', – ❑L STORAGE NO 7 ❑D I ENTRY � Q HALLWAY ° J a' o A C. A. 4 F I I i UP �B I © B ❑ 0 e o r LOP xblclg5-3 DESIGN AREA #7 DESIGN AREA#8 C` 1 HEAD 20x20 4 HDS 20x220 BUILDING TYPE 5- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 I/8" = 1'-0 FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA F STATIC : 65 SYSTEM NO, BLDG. TYPE 1 BLDG, TYPE 3 BLDG. TYPE 5 LOCATION BLDG. TYPE I BLDG. TYPE 3 BLDG. TYPE 5 SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL SPRINKLERS INC. 111 TECH DRIVE SANFORD, FLORIDA 32771 PLANTATION LAKES SANFORD APARTMENTS FLORIDA RESIDUAL : 50 HAZARD SEE SHEET SEE SHEET SEE SHEET TYPE OF SYSTEM SEE SHEET SEE SHEET SEE SHEET 324 1/2' 155' GLOBE JN—LF RES/PEND WHITE SEMI—REC. W—V B. LINES/MAIN CPUC FLOW : 1135 SPACING 2 OF 5 4 OF 5 5 OF 5 NO. OF SPRINKLERS 2 OF 5 4 OF 5 5 OF 5 .4 1/2' 155• GLOBE JN—LF RES/HSW WHITE SEMI—REC. W RISER SCH 40 DATE 4-25-99 K FACTOR DENSITY 2' UNDERGROUND CPUC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME : 3:45 INSIDE HOSE DESIGN AREA SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. : CITY MAIN OUTSIDE HOSE GPM FLOW C BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY D.F.S. RACK GPM RESIDUAL PSI 2 BRI CONTRACT NO. A1907 CUSTOMER PROJECT NO. SHEET NO. --3-- OF