Loading...
8100 Plantation Lakes Cir BLDG 8- 99-000758 (PLANTATION LAKES) (NEW APT BLDG) (A)9l ��cv�-Cw�v a� ZONE DATE CONTRACTOR(' SUBDIVISION: PERMIT #qq 07 LOT NO. BLOCK: ADDRESS PHONE# ,S34 COST 0 r LOCATION '�1 L yk) FEE $ OWNER�_/'LCyvt._stal l ADDRESS � r I � �? CCS fJTrA, STATE NO. PHONE #t PLUMBING CONTRACTOR FEE $ ADDRESS PHONE # -- ELECTRICAL CONTRACTOR Or -i/&3 3 l LLL !T�Ci FEE $ ADDRESS PHONE # MECHANICAL CONTRACTOR {��l" ' FEE $` F �1 ADDRESS PHONE # MISCELLANEOUS CONTRACTOR FEE $ ENERGY SECT. ADDRESS SEPTIC TANK PERMIT NO. SOIL TEST REQUIREMENTS (�_) SECTION: SQUARE FEET: MODEL: OCCUPANCY CLASS: FINISHED FLOOR ELEVATION REQUIREMENTS G) CERTIFICATE OF OCCUPANCY � _ ARCHITECISSUED # DATE: APPROVAL DATE: % FINAL DATt �_ �. Am S Y M B 0 L L E G E N D SYMBOL DESCRIPTION PART NUMBER OUTLET BOX FRCP FIRE ALARM CONTROL PANEL (FAC:P)� SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY FA.AH FIRE ALARM SYSTEM ANNUM. (FAAP ) SEE SPECIFICATION SHEET 4" SQUARE w/:SINGLE GANG RING o� HORN/STROBE SEE SPECIFICATION SWEET ¢ SQUARE x 2-1 / p" DEEP BOX STROBE �- � m� SEE SPECIFICATION SHEET 4" SQUARE x 2--1/8" DEEP BOX L� MANUAL STATION SEE SPECIFICATION SHEET 4, SQUARE w/SINGLE GANG RING W _ SPRINKLER WATER FLOW SWITCH BY OTHERS � FLEX TO DEVICE FROM J -BOX SPRINKLER TAMPER SWITCH BY OTHERS FLEX TO DEVICE FROM J --BOX. V) JUNCTION BOX BY OTHERS 4" SQUARE UNLESS NOTED - V END--OF--LINE DEVICE SFE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY D PHOTOELECTRIC SMOKE DETECTOR/BASE SEE SPECIFICATION SHE t 4" OCTAGON P1 ROOM MINI -HORN- - � SEE SPECIFICATION SHEET 4" SQUARE W/SINGLE GANG RING DESCRIPTION ZONE NUS BFR FLOW SWITCH -RISER I TAMPER SWITCH -RISER 2 SMOKE DETECTOR_rACP 3 ALL PULL STATIONS 4 W I �R E L_ E C E N D 3PHARD WIRE" LETTER A I DESCRIPTION #1v/2 COND_ SOLID RED - FPL TYPE USE NOTIFICATION CIRCUIT s D E #14/2 CONO, SOLID BLUE - FPL TYPE #18/2 COND. SOLID RED - FPL TYPE #18/2 COND. SOLID RED-- FPL TYPE mm 24VDC POWER CIRCUIT MANUAL -- INITIATION CIRCUIT AUTOMATIC. INITIATION CIRCUIT I -------------- � � Ovid NKO alo r[REVISIONS CS T E rl)RAINN: SEE:; CHECKED. PAL GATE: 5---25'--99 SCALE: 1 /8"=1 '.. 011 JOB NO. FA BUILDING TYPE 1 1 ST FLOOR 1 OF 3 SHEETS I C '�1 Ln � i � s W cc ( N 1 �� j N-) 00 j V) I ., Li < O 0- LLJ� C CL` C� F- Cn In q .-! x I Ca LL_. I a 0 I Y_ 0 r r)C W < m CO I � LLj I 0 I 0 It I I Q I rl)RAINN: SEE:; CHECKED. PAL GATE: 5---25'--99 SCALE: 1 /8"=1 '.. 011 JOB NO. FA BUILDING TYPE 1 1 ST FLOOR 1 OF 3 SHEETS r1. 0- LLJ� CL` C� F- Cn I a 0 I < Li! I I I I I I rl)RAINN: SEE:; CHECKED. PAL GATE: 5---25'--99 SCALE: 1 /8"=1 '.. 011 JOB NO. FA BUILDING TYPE 1 1 ST FLOOR 1 OF 3 SHEETS W I R E L E 0 E N D "HARD WIRE" LETTER DESCRIPTION USE A , #16/2 COND. SOLID RED - FPL TYPE NOTIFICATION CIRCUIT B #14/2 COND. SOLID BLUE - FPL TYPE 24VDC.- POWER CIRCUIT 0 #18/2 COND. SOLID RED --- FPL TYPE MANUAL -- INITIATION CIRCUIT E #18/2 COND. SOLID RED- FPL TYPE AUTOMATIC INITIATION CIRCUIT REVISIONS DATE PERMITC 5-25-99 r- S(AB-0L DESCRIPTION PART NUMBER OUTLET QOX FRCP FIRE ALARM CONTROL PANEL (FA -,:P) SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY FAA FIRE ALARM SYSTEM ANNUN. (FAAP) SEE SPECIFICATION SHEET 4" SQUARE vv/SINGLE GANG RING o � I-IORN/STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX STROBE SEE SPECIFICATION SHEET 4" SQUARE x 2-1/8" DEEP BOX u MANUAL, STATION SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE GANG RING 00 SPRINKLER WATER FLOW SNATCH BY OTHERS FLEX TO DEVICE FROM J -BOX _ SPRINKLER TAMPER SWITCH BY OTHERS FLEX TO DEVICE FROM J -BOX JUNCTION PDX BY OTHERS 4" SQUARE UNLESS NOTED - V'- END---OF---LINE DEVICE SEE SPECIFICATION SHEET PROVIDED BY ALERT SECURITY r ------------------------ -- - -------------- PHOTOELECTRIC SMOKE DETECTOR/BASE ---------------- SEE SPECIFICATION SHEET ----------------------- - --- 4" OCTAGON x ROOM MINI -HORN SEE SPECIFICATION SHEET 4" SQUARE w/SINGLE CANG RING W I R E L E 0 E N D "HARD WIRE" LETTER DESCRIPTION USE A , #16/2 COND. SOLID RED - FPL TYPE NOTIFICATION CIRCUIT B #14/2 COND. SOLID BLUE - FPL TYPE 24VDC.- POWER CIRCUIT 0 #18/2 COND. SOLID RED --- FPL TYPE MANUAL -- INITIATION CIRCUIT E #18/2 COND. SOLID RED- FPL TYPE AUTOMATIC INITIATION CIRCUIT REVISIONS DATE PERMITC 5-25-99 r- DRAWN: SEC CHECKED; RAL. 7' 5-25-99 SCALE: 1 /S"= l'-0" JOB NO. SHEET FA BUILDING TYPE 1 L0 00 00 3 SLEETS)" I— I- N � Elm* CL Ln Q Ld F� Lj < Q_} CD Y _ I (� �) x C-) Q %' z < Ld c� z V-3 LL - Ld < 10) Ls.J CL Ln DRAWN: SEC CHECKED; RAL. 7' 5-25-99 SCALE: 1 /S"= l'-0" JOB NO. SHEET FA BUILDING TYPE 1 2ND r 2 OF 3 SLEETS)" CL Ln Q Ld F� Ld ID V i C-) Q %' z < Ld c� 0 V-3 LL - CL DRAWN: SEC CHECKED; RAL. GATE: 5-25-99 SCALE: 1 /S"= l'-0" JOB NO. SHEET FA BUILDING TYPE 1 2ND FLOOR 2 OF 3 SLEETS)" 3RD 'FLOOR 3 4 5 [� 7. 8. 9. 10, 12, 13. GENERAL NOTES ALL WIRING MUST CONFORM WITH NEC ARTICLE 760 AND LOCAL CODES. ALL EQUIPMENT SHALL BE UL LISTED. ALL DEVICES SHALL BE COMPATIBLE WITH THE CONTROL PANELS. ALL INSTALLATION MATERIAL SUCH AS CONDUIT FITTINGS, BOXES, HANGERS ETC. ARE NOT SUPPLIED BY ALERT SECURITY INC. ALL INTIATING AND INDICATING CIRCUITS MUST BE SUPERVISED. CIRCUIT POLARITY MUST BE OBSERVED. WIRE RUNS ARE SHOWN DIAGRAMMATICALLY, EXACT LOCATION OF ALL EQUIPMENT TO BE DETERMINED IN THE FIELD, BUT SHALL CONFORM WITH BASIC LAYOUT AS SHOWN ON DRAWINGS TO PREVENT CIRCUIT OVERLOAD. MINIMUM CONDUIT SIZE WILL BE 3/4". CONDUIT SHALL BE NO MORE THAN 40% FILLED. DO NOT MARK ID NUMBERS ON DEVICES. LABEL BASE ONLY. FAN SHUTDOWN RELAYS MUST BE LOCATED WITHIN 3' OF STARTER COIL. PER NFPA 72, THE FIRE ALARM CONTROL PANEL SHALL NOT BE USED TO POWER ANY UNAUTHORIZED EXTERNAL DEVICE. DAMPER MOTOR AND FAN SHUTDWON (IF ANY) ARE TO BE COORDINATED IN FIELD WITH HVAC CONTRACTOR. ALL SURGE/TRANSIENT SUPRESSORS MUST BE CONNECTED TO APPROVED BLDG. GROUND. 1201 VAC POWER REQUIREMENTS FOR FIRE ALARM CONTROL PANEL AND FIRE ALARM SYSTEM RELATED EQUIPMENT OR DEVICES USED IN THIS PROJECT IS NOT THE RESPONSIBILITY OF ALERT SECURITY INC. DO NOT APPLY 120 VAC POWER TO CONTROL PANEL UNTIL A ALERT SECURITY INC. SERVICE TECNICIAN HAS INSPECTED ALL SYSTEM WIRING CONNECTIONS AND HAS APPROVED THE SYSTEM TO BE TURNED ON. /-- P L.AS T I C GROMMET CEILING= ALARM 4/STROBE IRE ALARM MANUAL STATION FLOOR BO" I N S TA I L.AT I O N DETAIL /lAN !-JAL QSTATI O H._ AND H HHHI HST R H B E TON. T.S. TO 170 FIELD VAC DEVICES PANEL MOUNTING DETAIL N.T.S. w REVISIONS DATE PERMIT-' 5-25-99 DRAWN: SEC CHECKED: PAL DATE: 5-25-99 SCALE: 1/8"-V-0" JOB NO. SHEET FA BUILDING T''Pc 1 :,ARD FLOOR 3 or- 3 SHEETS ON W � Oo Com! I Wit' W f cn H-- W �� 0 H n n 1 w < LL w Lij 0 Q m �C cD z D:' W 1-- I "t 7 Q0 v' 0 DRAWN: SEC CHECKED: PAL DATE: 5-25-99 SCALE: 1/8"-V-0" JOB NO. SHEET FA BUILDING T''Pc 1 :,ARD FLOOR 3 or- 3 SHEETS W f H-- n n w Lij 0 �H H� H H W O v' I.....1..._ DRAWN: SEC CHECKED: PAL DATE: 5-25-99 SCALE: 1/8"-V-0" JOB NO. SHEET FA BUILDING T''Pc 1 :,ARD FLOOR 3 or- 3 SHEETS NOTE ALL STEEL PIPE AND FITTINGS TO BE GALVANIZED. ALL STEEL PIPE AND FITTINGS TO BE WRAPPED & COATED. c,�T�.cq�d9 rza rte` rz), z UG2 r1pdF�� fJ 9J 9J '9J �o O 4• PVC (BY OTHERS) N TO DOMESTIC WATER TYPICAL APARTMENT BLDG. LEAD-IN DETAIL T - BUILDING - UNDERGROUND GENERAL NOTES: 1. ALL MATERIAL AND INSTALLATION TO BE IN ACCORDANCE WITH NFPA 24 AND THE CITY OF SANFORD- 2. ALL J©iN'I'S TO BE RESTRAINED IN ACCORDANCE iNIM NFPA 24, A14D iiil C'i'l OF SANFORD. J 3. ALL PIPING TO HAVE A 36„ MINIMUM DEPTH OF BURY FROM TOP OF PIPE. 4. ALL PIPING TO BE HYDROSTATICALLY TESTED AND FLUSHED IN ACCORDANCE WITH NFPA 24 AND THE CITY OF SANFORD. _XTERIOR WALL SND . .---------------------------------------------------------------------------------------------.-----------------..__.-----...----..__.-------- .----..------------------------------------------------ — ------ PROTECTION oPERll� `,NE I/ C FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY E LTA FIRE STATIC : 65 SYSTEM NO. LOCATION SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL DPLANTATION LAKES APARTMENTS RESIDUAL 50 HAZARD TYPE OF SYSTEM SPRINKLERS INC. FLOW 1135 SPACING NO. OF SPRINKLERS 111 TECH DRIVE SANFORD, FLORIDA 32771 SANFORD FLORIDA DATE 4-25-99 K FACTOR DENSITY DRAWN BY1 F. LUPO DATE: 4-1-99 DCC CONSTRUCTORS INC. TIME - 345 INSIDE HOSE DESIGN AREA SPRKS. ON JOB. 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. CITY MAIN OUTSIDE HOSE GPM FLOW a BR2 UNDERWRITERS, LOCAL AUTHORITY LONGWOOD, FL. 32750 IBY : D.F.S. RACK GPM I I I I I RESIDUAL PSI a BR2 CONTRACT N0, A1907 CUSTOMER PROJECT NO. SHEET NO. --i-- OF __5 _ GENERAL NOTES: 1. ALL WORK SHALL BE DONE 1N ACCORDANCE WITH NFPA 13R, 1996 EDITION, AND THE LOCAL AUTHORITY. 2. ALL MATERIAL AND DEVICES TO BE IN ACCORDANCE WITH NFPA 13 & 13R 1996 EDITION. 3. ALL PIPE AND FITTINGS TO BE CPVC, EXCEPT FOR THE BUILDING RISER, WHICH WILL BE SCH. 40 BLACK STEEL 4. ALL RESIDENTIAL SPRINKLER HEAD SPACING TO CONFORM WITH THE MAN- UFACTURERS LISTING. 5. ALL FIREWALL PENETRATIONS TO BE SEALED IN ACCORDANCE WITH THEIR RATING. 6. SPRINKLERS SHALL BE OMITTED IN THE FOLLOWING AREAS, PER NFPA 13R, 1996 EDITION, SECTION 2-6 EXCEPTIONS 1 THRU 4 CLOTHES CLOSETS, LINEN CLOSETS, AND PANTRIES UNDER 24 SQ. FT., PORCHES, BALCONIES, CORRIDORS, AND STAIRS WHICH ARE OPEN AND ATTACHED, AND ALL OTHER AREAS NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGE. 6' 12OV. ELECTRIC BELL SPARE HEAD BOX W/ WR GLOBE VI NOTE: ALL PIPE SIZES ARE 3/4" UNLESS NOTED OTHERWISE. ROOM LEGEND A� - LIVING ROOM ® - BEDROOM CD - KITCHEN []D - CLOSET EC� - UTILITY [F] - DINING ROOM [G - PORCH - H. V. A. C. n - BATHROOM LL� - STORAGE [M - ENTRY ON - HALLWAY TO SYSTEM i nur avw I ,. i 'RESSURE GAUGE FLOW SWITCH (WIRED BY OTHERS) ACCESS PANEL 30' X 20' 1112 RESIDtN7ZAl vDC C0Qt�1. ?' WATTS 0070T DOUBLE CHECK VALVE ASSY. ?' RBALL BFV. W/ T.S. (WIRED BY OTHERS) PRESSURE GAUGE TYPICAL BLDG. RISER DETAIL ^"1 '10LE TOLCO Tvc N. T. S. '10LE TOLcO Pvc HANGER DETAIL N.T.S. I NOTE1 CDC. DECK SHOWN. HOWEVER; THESE TABLES APPLY FOR ANY TYPE OF CONST SEE TABLE I-\ 1 SEE TABLE 3 1 SEE TABLE 2 1 SEE TABLE 3 1 SEE TABLE 2 BRACE/HANGER BRACE/HANGER HANGER SPACING Z BRACE /HANGER 4 '7( LEG END, 6 FLOW TEST DATA TAKE I TABLE 2 MAXIMUM SUPPORT SPACING MAXIMUM SUPPORT SPACING FROM END LINE HEAD FROM INLINE HEAD TAKE 3 MAXIMUM St1PPORT SPACING BETWEEN HANGERS PIPE SIZE LESS THANMORE THAN LESS THAN MORE THAN 100 PSI 00 PSI 100 PSI 00 PSI ANY PSI 3/4' 0'-9' '-6' 4'-0' '-0' 5'-6' 11 W-12' - 5'-0' k -Of 6'-0' 1-114' 0'-16' 0')p' 6'-0' sy 6'-6' 1-1/2' 0'-24' T-0' YA T-0' 2' 0'-24'-1 T-0' '-o• 8'-0' 2112• 0'-24' 0'-12' 7'-0' 7'-0' 9'-0' 3' 0'-24• 0'-12• T-0' 7'-0' 10'-0' I NOTE1 CDC. DECK SHOWN. HOWEVER; THESE TABLES APPLY FOR ANY TYPE OF CONST SEE TABLE I-\ 1 SEE TABLE 3 1 SEE TABLE 2 1 SEE TABLE 3 1 SEE TABLE 2 BRACE/HANGER BRACE/HANGER HANGER SPACING Z BRACE /HANGER 4 '7( LEG END, 6 FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO. DATE REVISION DESCRIPTION BY DELTA F SPRINKLERS INC. 111 TECH DRIVE SANFORD, FLORIDA 32771 STATIC 65 SYSTEM NO. D/A #1 D/A #2 D/A #3 LOCATION D/A #1 D/A #2 D/A #3 SYMBOLS QUAN. SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENTS SANFORD FLORIDA RESIDUAL � 50 HAZARD LIGHT LIGHT ORD. TYPE OF SYSTEM WET WET WET & 324 1/2' 155' GLOBE JN -LF RES/PEND WHITE SEMI-REC. ji'-%' B. LINES/MAIN CPVC FLOW 1135 SPACING 2Ox20 2Ox20 130 NO. OF SPRINKLERS 1 4 6 44 1/2' 155' GLOBE JN -LF RES/HSW WHITE SEMI-REC. 1�' RISER SCH 40 DATE 4-25-99 K FACTOR 2.8 2.8 5.6 DENSITY .10 .10 .15 ® 1/2' 155' GLOBE JN STD/PEND WHITE SEMI-REC. 2' UNDERGROUND CPVC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME 345 INSIDE HOSE 45 45 45 DESIGN AREA 1 HD 4 HDS ENTIRE SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. CITY MAIN OUTSIDE HOSE 0 0 0 GPM FLOW 2 BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY D.F.S. RACK GPM 0 0 0 RESIDUAL PSI e BRI CONTRACT NO. A1907 CUSTOMER PROJECT NO. SHEET NO. __2__ OF I 'G ► p I 1 ®i ❑ II® UP ❑ � I a F ❑ �,� I i I a © 5 ® ® ' ® {� J J 4 i Fig 0 uj� 7/1', El m z- \�i� T' �2 CI1 © C2 C3 F ❑ I O a �— LN a �� -�\` a o o J ❑ c3 F❑ r � ��` T1 ❑ // E�— 4 ❑ I� © © 6� DF ❑ 3 I Q � 1� II ® (5 L4�xl � ��O ❑ I ( J o L so ail I d I C .1 1 ❑ o 0 0 0 �o o I o 0 I D B; ❑; B ❑ � � � �. B I ilP 1 Bfl DESIGN AREA #8 DESIGN AREA #7 —, l i 4 HDS 20x20 1 HEAD 20x20 DESIGN AREA #4 DESIGN AREA #5 4 HDS 20x20 1 HEAD 20x20 BUILDING TYPE 1- 3RD FLOOR FIRE PROTECTION PLAN BUILDING TYPE 3- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 3,7,8,16, & 17 1/8" = 1'-0 TYPICAL FOR BLDG. #'S 1,4,5,9,10,12,13 & 15 1/8" = 1'-0 D I I j 1 ! ® D UP B F D A 4 1 G❑ ® C. D F ❑ ® -- n I d 1 ` � ® I 1 ® ALL PIPE SIZES ARE 3/4" UNLESS NOTED OTHERMISE. ® e M 1jo L=La, 4a 1- I E ' C a ROOM LEGEND 02 rcl, It;�� 1vK„e ,i�' ,.s,; .� ,, — ® LIVING ROOM `71' Q c3 ❑C cz �. �j o C -- ❑ 1• i' 1' 1 1. ,lE 1 1 i 1 1 J i 1' ❑ B —BEDROOM 7-0 S— 10-31 19-9 1-10 5-0 0— :, — 7 5=1a — — 2A I 11 �2 I — —� �, — 17-4 - !' c, - - C❑ -KITCHEN �,J I -. U I I ❑D — CLOSET DI T1 7 'Ifil❑ J ❑ UTILITY D ❑ C I ® I, I F '' F e� ,, , ' — DINING ROOM J a G— PORCH �\ E 1 2 Q ❑ © — H. V. A. C. I� , 1 R ® — BATHROOM FB ❑ �” �f ❑L STORAGE _ I ` B V W B ❑ ® ENTRY II I® Ifl I A J I I I ❑N — HALLWAY a © © ® !; c � i . RG AM UP © ® ( D .� o B � 0 I fl xb�ag5-3 DESIGN AREA #7 DESIGN AREA #8 1 HEAD 20x20 4 HDS 20x20 BUILDING TYPE 5- 3RD FLOOR FIRE PROTECTION PLAN TYPICAL FOR BLDG. #'S 2,6,11,14 & 18 1/8" = 1'-0 FLOW TEST DATA DESIGN CRITERIA HYDRAULIC CALCULATIONS AUTOMATIC SPRINKLER LEGEND MATERIALS NO, DATE REVISION DESCRIPTION BY DELTA F STATIC 65 SYSTEM NO. BLDG. TYPE 1 BLDG. TYPE 3 BLDG. TYPE 5 L❑CATION BLDG. TYPE i BLDG. TYPE 3 BLDG. TYPE 5 SYMBOLS QUAN, SIZE TEMP. MAKE MODEL TYPE FINISH ESC. SIZE LOCATION TYPE 1 4-1-99 GENERAL CONTRACTOR SUBMITTAL FJL PLANTATION LAKES APARTMENT RESIDUAL 50 HAZARD SEE SHEET SEE SHEET SEE SHEET TYPE OF SYSTEM SEE SHEET SEE SHEET SEE SHEET 324 1/2' 155' GLOBE JN -LF RES/PEND WHITE SEMI-REC. W -V B. LINES/MAIN CPUC 1� SPRINKLERS 111 TECH DRIVE SANFORD, INC. FLORIDA 32771 SANFORD FLORIDA FLOW 1135 SPACING 2 OF 5 4 OF 5 5 OF 5 NO. OF SPRINKLERS 2 OF 5 4 OF 5 5 OF 5 1/2' 155` GLOBE JN -LF RES/HSW WHITE SEMI-REC. 1ST' RISER SCH 40 DATE 4-25-99 K FACTOR DENSITY 2' UNDERGROUND CPUC DRAWN BY: F.LUPO DATE: 4-1-99 DCC CONSTRUCTORS, INC. TIME : 3:45 INSIDE HOSE DESIGN AREA SPRKS. ON JOB: 2,808 SCALE: AS NOTED 355 SOUTH C.R. 427 LOC. : CITY MAIN OUTSIDE HOSE GPM FLOW @ BRI UNDERWRITERS: LOCAL AUTHORITY LONGWOOD, FL. 32750 BY D.F.S. RACK GPM RESIDUAL PSI @ BRI CONTRACT NO. A1907 CUSTOMER PROJECT NO. SHEET NO. OF --5- -5-