203-205 Towne Center Blvd - BC03-001490 (GATEWAY PLAZA) (INTERIOR REMODEL) (A)El ELECTRICAL CONTRACTOR MECHANICAL CONTRACTOR PLUMBING CONTRACTOR� MISCELLANEOUS CONTRACTOR PERMIT NUMBER MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE FEE d d atvw SUBDIVISION J�j J W L-2 4 in r INTERIOR ALTERATION PLANS FOR: CJO, INC. AT GATEWAY PLAZA SPACE N0. A-2 AND A-3 SANFORD, FLORIDA VICINITY MAP LAKE000rMONROE 46 ,--SITE LOCATION GATEWAY PLAZA NORTH INDEX OF DRAWINGS CS COVER SHEET /GEN. NOTES EXISTING SITE PLAN A-1 OVERALL FLOOR PLAN —PHASE 2 & 3 A-2 SUITE FLOOR PLAN —PHASE 3 A-3 ENLARGED FLOOR PLAN —PHASE 3 A-4 OVERALL REFLECTED CEILING PLAN — PHASE 2 & 3 A-5 WALL SECTIONS /FIRE RATING DETAILS & MISC. DETAILS A-6 AIR CONDITIONING PIAN A-7 ELECTRICAL FLOOR PLAN PROJECT DATA AREA OF IMPROVEMENT: PUBLIC TOILET FIXTURE COUNT: WATER CLOSETS URINAL LAVATORIES BUILDING CODE MECHANICAL CODE PLUMBING CODE ELECTRICAL CODE UFE SAFETY CODE FIRE CODE FLORIDA ACCESSIBILITY CODE ENERGY EFFICIENCY CODE CONSTRUCTION TYPE: AUTOMATIC FIRE SPRINKLERS OCCUPANCY TYPE: PREVIOUS USE: 5,573 SQ. FT. MEN WOMEN EXIST, NEW TOTAL EXIST. NEW TOTAL 1 0 1 1 1 2 0 0 0 0 0 0 1 0 1 1 1 2 2001 FLORIDA BUILDING CODE 2001 FLORIDA MECHANICAL CODE 2001 FLORIDA PLUMBING CODE 1999 NEC --- 2000 NFPA 101 2001 FLORIDA FIRE PREVENTION CODE 2001 FLORIDA BUILDING CODE (CHAPTER 11) 2001 FLORIDA BUILDING CODE (CHAPTER 13 IV UNPROTECTED YES --- GROUP B - BUSINESS RETAIL ARCHITECTURAL SYMBOLS DETAIL SECTION INTERIOR ELEVATION COLUMN NUMBER DOOR NUMBER ELEVATION (7#1� DETAIL LETTER OR NUMBER 00 SHEET WHERE DETAIL IS DROWN SECTION LETTER OR NUMBER DIRECTION OF SECTION CUT SHEET WHERE SECTION IS DRAWN ELEVATION LETTER OR NUMBER N#N SHEET WHERE ELEVATION IS DR4WP QCOLUMN CENTER LINE i O HEIGHT ABOVE FINISHED FLOOR (A.F.F. LEGAL DESCRIPTION By: Sanford Fire Date: Z-) tioi DiY* INTERIOR FINISH FIRE CHARACTERISTICS FLAME SPREAD RATINGS CLASS FLAME SPREAD FUEL CONTRIBUTION SMOKE DENSITY PLASTIC LAMINATES --- 165 --- 135 EPDXY PAINT FINISH A / 1 10 0 0 ACOUSTICAL TILE --- 25 --- 50 Z PROJECT GENERAL NOTES THE CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THAT FURNISHED BY SUBCONTRACTORS. 2. DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS; DO NOT SCALE DRAWINGS TO DETERMINE ANY LOCATION. THE OWNER SHALL BE NOTIFIED IF ANY DISCREPANCY OCCURS PRIOR TO CONTINUING WITH WORK. 3. DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE NOT INTENDED. THE CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT AND OWNER ANY SUCH DISCREPANCIES PRIOR TO COMMENCING WORK. 4. THE CONTRACTOR SHALL REPORT TO THE ARCHITECT ANY ERRORS, INCONSISTENCIES, OR OMISSIONS HE MAY DISCOVER. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERRORS AFTER THE START OF CONSTRUCTION WHICH HAVE NOT BEEN BROUGHT TO THE ATTENTION OF THE ARCHITECT. THE MEANS OF CORRECTING ANY ERROR SHALL FIRST BE APPROVED BY THE ARCHITECT AND OWNER, 5. ALL PLAN DIMENSIONS ARE FROM FACE OF STUD OR FACE OF FINISH OR FACE OF CMU UNLESS OTHERWISE NOTED. 6. ALL WORK AND MATERIALS SHALL CONFORM TO THE REQUIREMENTS OF ALL FEDERAL, STATE, LOCAL AND OSHA CODES AND LOCAL RESTRICTIONS, 7. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING MECHANICAL AND ELECTRICAL SERVICES AND DISTRIBUTION SYSTEMS WHETHER SHOWN OR NOT, AND TO PROTECT THEM FROM DAMAGE, THE CONTRACTOR SHALL BEAR ALL EXPENSE OR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE PERFORMANCE OF THE WORK. 8. FIRE EXTINGUISHERS - SIZE,TYPE,NUMBER AND LOCATION IS TO BE COORDINATED WITH THE BUILDING AND FIRE DEPARTMENTS. 9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPLACEMENT OR REMEDY OF ANY FAULTY, IMPROPER OR INTERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR WITHIN ONE (1) YEAR OR AS OTHERWISE SPECIFIED FOR A SPECIFIC COMPONENT AFTER THE COMPLETION AND ACCEPTANCE OF THE WORK UNDER THIS CONTRACT. 10. THE CONTRACTOR SHALL PROVIDE BACKING/BLOCKING AS REQUIRED FOR MOUNTING OF WALL MOUNTED SHELVES AND CABINETS, ALL WOOD BLOCKING, PLYWOOD SHEATHING, SUB -FLOORING AND WOOD FRAMING CONCEALED WITHIN WALL, FLOOR OR CEILING SPACES SHALL BE PRESSURE TREATED WHEN INSTALLED AGAINST CONCRETE BLOCK. 11, SILICONE CAULK SHALL BE USED AT THE FOLLOWING LOCATIONS INCLUDING, BUT NOT LIMITED TO: 1. METAL DOOR AND WALL CONNECTION 2. CONDUIT AND PIPE PENETRATIONS AT WALLS AND CEILING. 3. JUNCTION OF MILLWORK (CABINETS, SHELVES, ETC.), 12, CONTRACTOR IS TO CLEAN WORK AREAS ON A DAILY BASIS SO AS NOT TO ACCUMULATE DEBRIS. 13. UPON PROJECT COMPLETION CONTRACTOR IS TO CLEAN WORK AREAS AND JOB SITE THOROUGHLY SO AS TO REMOVE ALL ONSTRUCTION DUST, RESIDUE, AND DEBRIS. 1 14. DO NOT OBSTRUCT STREETS, SIDEWALKS, ALLEYS OR OTHER I RIGHT-OF-WAY WITHOUT FIRST OBTAINING PROPER PERMITS. 15. ALL WORK SHALL BE ACCOMPLISHED WITH QUALITY WORKMANSHIP OF THE HIGHEST INDUSTRY STANDARDS. ALL MATERIALS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS AND RECOMMENDATIONS. MATERIALS AND METHODS SHALL CONFORM TO THE APPROPRIATE NATIONAL TRADE BOOK; I.E. TILE COUNCIL OF AMLRICA HANDBOOK FOR CERAMIC TILE INSTALLATION, ARCHITECTURAL WOODWORK I INSTITUTE, "QUALITY STANDARDS," ETC. 16, THE OWNER MAY PERFORM ADDITIONAL WORK THAT IS NOT PART OF THIS CONTACT WITH HIS OWN FORCES, UNDER SEPARATE CONTRACTS AND/OR WITH OTHER CONTRACTORS. THE CONTRACTOR SHALL COOPERATE WITH THE OWNER AND OTHER CONTRACTORS AND COORDINATE HIS WORK WITH THE OWNER SO THAT THE WORK BY OTHERS CAN BE INCORPORATED IN A TIMELY MANNER. 17, THE CONTRACTOR SHALL BE RESPONSIBLE FOR JOB SAFETY, AND SHALL TAKE ALL NECESSARY PRECAUTIONS TO ENSURE SAFETY OF WORKS AND OCCUPANTS AT ALL TIMES. 18. ALL ELECTRICAL, MECHANICAL, AND PLUMBING WORK SHALL CONFORM TO STATE AND LOCAL REQUIREMENTS, 19. REMODEL WORK SHALL NOT OBSTRUCT, OR CAUSE TO BE INOPERATIVE, EXISTING FIRE ALARM SYSTEMS. MODIFICATION TO FIRE ALARM SYSTEMS SHALL BE PERFORMED BY A FIRE ALARM CONTRACTOR, WHO SHALL OBTAIN A PERMIT FROM THE BUILDING DEPT. PRIOR TO WORK. 20. THE CONTRACTOR SHALL MAINTAIN, IN GOOD CONDITION, ONE COMPLETE SET OF CONSTRUCTION DOCUMENTS WITH ALL REVISIONS, ADDENDUMS AND CHANGE ORDERS ON THE PREMISES AT ALL TIMES. THE DOCUMENTS ARE TO BE KEPT UNDER THE CARE OF THE JOB SUPERINTENDENT. I21. THE CONTRACTOR SHALL FURNISH AND INSTALL ALL MINOR ITEMS WHICH ARE OBVIOUSLY AND REASONABLE NECESSARY TO COMPLETE ANY INSTALLATION. 22. IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO ISOLATE ALL WORK AREAS IN SUCH A WAY AS TO PROTECT THE ADJACENT BUILDING SPACES AND STRUCTURE. 23. MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING CODES/ORDINANCES. 24. ACCEPT PREMISES AS FOUND. OWNER ASSUMES NO RESPONSIBILITY FOR THE CONDITION OF THE EXISTING BUILDING SITE OR EXISTING STRUCTURES AT THE TIME OF BIDDING OR THERE AFTER, 25. GYPSUM WALLBOARD AND SUSPENDED CEILING SYSTEMS SHALL CONFORM TO REQUIREMENTS OF LOCAL BUILDING CODES AND ORDINANCES, 26. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO SECURE ALL NECESSARY PERMITS AND APPLICATIONS, 27. ALL NEW DRYWALL AND ABUTTING SURFACES ARE TO BE FINISHED TO A SMOOTH PAINTABLE SURFACE. 28. ALL EXISTING INTERIOR WALLS ARE TO BE PATCHED AND POINTED UP AS REQUIRED TO PROVIDE A SMOOTH UNIFORM PAINTABLE SURFACE. 29. GYPSUM WALL BOARD SHALL BE INSTALLED WITH ALL CORNER BEADS, TRIM, ACCESSORIES, MOULDINGS, ETC., AS REQUIRED FOR COMPLETION, TAPED AND SANDED READY FOR PAINT BY DRYWALL CONTRACTOR, ALL WORK WILL BE PERFORMED IN ACCORDANCE WITH U.S. GYPSUM STANDARDS. 30. UPON COMPLETION OF WORK THE GENERAL CONTRACTOR SHALL CLEAN ALL WINDOWS (INTERIOR AND EXTERIOR), JAMBS, CLEAN, SEAL AND WAX ALL VINYL TILE FLOORS, ALL TOILET ROOMS, SALES FLOOR CAREFULLY REMOVING THOROUGHLY ALL I TAPE, LABELS, AND OTHER CONSTRUCTION DIRT AND DEBRIS. RECEIVED APR 0 o 3 F�; V) Z 0 0 �j CLI a z 0 0 � A W E-+ 1--1 O F+i w o0 O g L0 o z EU)00 �V woODoCD H o :5 N Q w x CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. O Li Ln Z • N O p 0 za o a a "� � �` a o LTJ W J O Q a can a I' wxi-w-jo QIF- T-�ZW Ozqp ti.tn..1tYU _ �ww' WO00}Zlt <zw oz 'Q: Z Lj `a Un a r`cwt1-"( Ltl N H w U U W O af_va'00L' u a ZC9 O u1 W Z pf�Lmh �QWGW jW A",,pwZ1,i-O'w�eT i; J J.aw .L Wa W I_ U w¢O,nu)T?IWTL. W wF`t�W gr- r.It.�fJl O W s Q CL p wc`ew0WUW00 WwmL saa z It rl (L J Qf''�q(AUFR'> i n s i r L ,� W1 L O wU(jCZG) H rZt _ WO E i JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479CSU ti SHEET d s W r r - CAO),9 TOYS R US SERVICE MERCHANDISE KEY PLA z N.T.S. AM \ FLOOR PLAN LEGEND: F777= EXIST, WALL TO REMAIN. �l IRETAIL stiF� �'q NEW PHASE 3 WALL. SEE WALL q, SECTIONS, q, NEW PHASE 2 WALL, SEE WALL i Al \\\ RETAIL A FUTURE --o i A2 A3 i A4 i A4.8 OVERALL FLOOR PLAN - RETAIL 'A' SCALE: 1/8" , l' -O" 0 .3 0 43 0 0 L 0 A W E-4 o � O �u1 00 W ® ® g M O Q V1 Z -J C) cI _ ►n ao F -131 LL. . . v)Lu �, o p xx `'p a N L W0 Q a _ c w 0 0 c �L O O a� a. C 7 7 V D nc=) o ...... ,ice z -) U CONTRACTOR /SHALL VERIFY ALL CONDITIONS :AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. o .. o Q o 0 v V N � N N o CL t� a cao o l O ami Q 3►N� n a o LLJ p o (n n JQ can a N t Q Q cy- o V O W Q CL � U a C 0 0 r M V) z 0 0 Q 0 0 Z .3 0 M 0 0 N z t 0 U DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479AIU SHEET lam. — P ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING HEIGHT ENTRY CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" SHOWROOM CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" SHOP CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #3 CARPET 4" VINYL . PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #4 CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" HALL #2 CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" NEW RESTROOM VINYL 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" BREAK ROOM VINYL 4" VINYL PAINT ALL WALLS EXIST, ACOUST./GRID 10'-0" OFFICE #2 CARPET 4" VINYL PAINT ALL WALLS NEW ACOUST,/GRID 10'-0" HALL #1 VINYL 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE # 1 CARPET 4" VINYL PAINT ALL WALLS NEW ACOUIST./GRID 10'-0" ELEC. ROOM VINYL 4" VINYL PAINT ALL WALLS NEW ACOUIST./GRID 10'-0" EXIST, MEN EXIST. EXIST, PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" EXIST. WOMEN EXIST. EXIST. PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" EXIST. VEST, EXIST. EXIST. PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" DOOR SCHEDULE # SIZE THK. MATERIAL FRAME TYPE REMARKS HARDWARE 1. PR. 3'-0"x7'-0" 1-3/4" WD/GLASS METAL FRENCH STEEL REINF. 2, 3'-0" X 7'-0" 1-3/4" WD/GLASS METAL FRENCH STEEL REINF, 3. 3'-0" X 6'-8" 1-3/4" WD/GLASS WOOD FRENCH INTERIOR DOOR 1 4. 3'-0" X 6'-8" 1-3/4" WD/GLASS WOOD FRENCH INTERIOR DOOR 2 5. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE 6. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE 7. 2'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE E1. 3'-0" x 7'-0" 1-3/4" EXIST, METAL EXIST. FLUSH EXIST, EXTERIOR EXIST. ^ E2. 3'-0" x 6'-8" 1-3/4" EXIST, WOOD EXIST. FLUSH EXIST, EXTERIOR EXIST, GROUP 1 1-1/2 PR. BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 LOCKSET SCHLAGE 2-3/4" BSXASA 1 WALL MOUNTED DOOR STOP IVEY GROUP 2 1-1/2 PR. BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 PASSAGE SET SCHLAGE 2-3/4" BSXASA 1 WALL MOUNTED DOOR STOP IVEY WALL MOUNTED TRANSPARENCY BY OTHERS DISPLAY CASES BY OTHERS —r 0 LF ., \ s�o:j" qfs� �, �, y ; 1 � e r A Y e ID P N Ln U o ® EXISTIf�C� QRINRNG '` ' i' L FO NTAI�I ' h - 2 A-5 A-5 I U El- 6,-� 5-+ 91-011 E_ 0 E2 ' i' il) E (FE2 m V) z 0 V) a 0 Uz- DOOR SCHEDULE # SIZE THK. MATERIAL FRAME TYPE REMARKS HARDWARE 1. PR. 3'-0"x7'-0" 1-3/4" WD/GLASS METAL FRENCH STEEL REINF. 2, 3'-0" X 7'-0" 1-3/4" WD/GLASS METAL FRENCH STEEL REINF, 3. 3'-0" X 6'-8" 1-3/4" WD/GLASS WOOD FRENCH INTERIOR DOOR 1 4. 3'-0" X 6'-8" 1-3/4" WD/GLASS WOOD FRENCH INTERIOR DOOR 2 5. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE 6. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE 7. 2'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE E1. 3'-0" x 7'-0" 1-3/4" EXIST, METAL EXIST. FLUSH EXIST, EXTERIOR EXIST. ^ E2. 3'-0" x 6'-8" 1-3/4" EXIST, WOOD EXIST. FLUSH EXIST, EXTERIOR EXIST, GROUP 1 1-1/2 PR. BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 LOCKSET SCHLAGE 2-3/4" BSXASA 1 WALL MOUNTED DOOR STOP IVEY GROUP 2 1-1/2 PR. BUTTS SELF CLOSING SPRING HINGES 4-1/2 X 4-1/2 1 PASSAGE SET SCHLAGE 2-3/4" BSXASA 1 WALL MOUNTED DOOR STOP IVEY WALL MOUNTED TRANSPARENCY BY OTHERS DISPLAY CASES BY OTHERS —r 0 LF ., \ s�o:j" qfs� �, �, y ; 1 � e r A Y e ID P N Ln U o ® EXISTIf�C� QRINRNG '` ' i' L FO NTAI�I ' h - 2 A-5 A-5 I U El- 6,-� 5-+ 91-011 E_ 0 E2 ' i' il) E (FE2 m V) z 0 V) a 0 Uz- WALL MOUNTED TRANSPARENCY BY OTHERS DISPLAY CASES BY OTHERS —r 0 LF ., \ s�o:j" qfs� �, �, y ; 1 � e r A Y e ID P N Ln U o ® EXISTIf�C� QRINRNG '` ' i' L FO NTAI�I ' h - 2 A-5 A-5 I U El- 6,-� 5-+ 91-011 E_ 0 E2 ' i' il) E (FE2 m V) z 0 V) a 0 Uz- oo ( Ln -0 5 3,, .4. E-.+ M-�-1 :0 �� E+ Ln 2 -5 O,' I w \I o 0 Z r\ o �, I g M M 5 5 Z Q�_ I n 1'� _ � U 00 A-5 A-5 p' r 3 o 0 5 fL � ZD CD V) O3 i/1 0 3 3 N Q O � `b 11 A-5 0 WALL MOUNTED ~ TRANSPARENCY �• a BY OTHERS ��• �' 5 2 A-5 �A-5 r. 3 5 n I c A-5 0 WALL MOUNTED ��'• A-5 �, o TRANSPARENCY BY OTHERS PGj V l C) P D N �\� .2 FliL CONTRACTOR�SHALL VERIFY 9'-0" 3'-0" ALL CONDITIONS, --AND 6 o DIMENSIONS AT THE JOB SITE I AND NOTIFY THE ARCHITECT EXISTING '' 1 OF ANY DIMENSIONAL ERRORS, STEEL W s OMISSIONS OR DISCREPANCIES U Q BEFORE BEGINING OR COLUMN EXISTING — D FABRICATING ANY WORK, GQ� STEEL 0 00 NOT SCALE DRAWINGS. COLUMN �W x C3 � WALL MOUNTED LAS TRANSPARENCY ' BY OTHERS Q O 0 0 SHOW CASES (BY OTHERS) oy��, O tic DISPLAY CASES �p'L�� ��ppo \ BY OTHERS V N 4 A-5 { Q 6 Q N o �b I oCLM a. ¢I ¢o � Z o� 's- > 0 a o N O \ O 4 `� W w z o ® va A-5 WALL MOUNTED TRANSPARENCY v •7 SHOW CASES SHOW CASES BY OTHERS Q (BY OTHERS) (BY OTHERS) � o O 4 a LLJ A-5 Z TRANSPARENCY DISPLAY TRANSPARENCY DISPLAY �s `o BY OTHERS BY OTHERS 4 Q L CL \ \ \ \ _ _ _ _._._.—._a.---------- _ _ _ _ _ _ ----- _A wl- _ _ _ _ _ _ _ _ _ ----------------- ----------- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ......... EXISTING STOREFRONT �{ REMOVE EXISTING DOOR TRANSOM AND SIDE LIGHT. FILL IN WITH NEW 11 -7------ ; ;------ STOREFRONT FRAMING AND GLAZING TO MATCH EXISTING o STOREFRONT. 0 0 N Q 0 U FLOOR PLAN SCALE: 3/16" = 1'-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A2U SHEET A-2 NEW 3" V.T.R. - EXIST, 4" WASTE NEW 2" \ I VENT -� \ I I I I --f -- NEW LAV. NEW 4" WASTE --NEW 2" EXIST. 4 VENT WASTE ,A.- NEW W.C. NEW LAV. — NEW 2" -NEW WALL WASTE CLEANOUT � SANITARY RISER DIAGRAM SCALE; N.T.S. NEW GRAB BARS PROVIDE BLOCKING AS REQUIRED FOR SUPPORT 3'-6" 1 d- r� NEW SURFACE MOUNTED- L NEW WATER TOILET TISSUE HOLDER CLOSET RESTROOM B SCALE 112 " = 1'-0" NEW GRAB BARS PROVIDE MIRROR BLOCKING AS REQUIRED ---FOR SUPPORT NEW SURFACE MOUNTED TOILET TISSUE HOLDER x CO rn I 1'-6" NEW WATER CLEAR CLOSET RESTROOM A SCALE 1/2" = 1'-0" NEW SINK WRAP DRAIN PIPE WITH INSULATION -p 43 0 C�m_ Z v L NV T � C O d. Q 7 ` � V) 0 N V) C- M Z I dao Z o� >-:z I_' Q N O Q I o I..1..1 o W N J 0Q Q a (n V V I- Q O o V O Q W O z -: i H_ N V 1 N L C O L V C O J V 7 /Mq O u O O o Z N In M o g M S O °�' �✓ O Q V 1 0 IQ u, r - Ln 00 3 v` N Iw- c:) 0 W r�N C) p VJ O z _t V �T O x 3 V N Q Li o F+1 Q) 0 0-4 0 r? L l n u o w V) 0 c `L O O -F� O E O � O c `L rn CONTRACTOR SHALL VERIFY ALL CONDITIONS -AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. U) z V Z v L NV T � C O d. Q 7 ` � V) 0 N o C- M Z I dao o� >-:z I_' Q N Q I o I..1..1 o W S J 0Q Q a (n V V I- Q O o V O W ENLARGED FLOOR PLAN DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A3U w SHEET h 41.54 '{ .vp tEF i f i Z v o D T � C O d. CL 0 a ENLARGED FLOOR PLAN DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A3U w SHEET h 41.54 '{ .vp tEF i f i LEGEND: EXISTING SUSPENDED = ACOUSTICAL CEILING SYSTEM i s D NEW SUSPENDED ACOUSTICAL CEILING SYSTEM, MATCH EXISTING, NEW (N), EXISTING (E) OR RELOCATED (R), 2'x4', 4 TUBE RECESSED FLUORESCENT LIGHT FIXTURE WITH PARABOLIC LENS, NEW FIXTURES TO MATCH EXISTING, NEW (N), EXISTING (E) OR RELOCATED (R), 2'x4', 4 TUBE RECESSED FLUORESCENT LIGHT FIXTURE WITH PRISMATIC LENS, NEW FIXTURES TO MATCH EXISTING, NEW (N), EXISTING (E) OR RELOCATED (R), 2'x4', 4 TUBE RECESSED FLUORESCENT LIGHT FIXTURE WITH PARABOLIC LENS, WIRED TO FUNCTION AS A NIGHT LIGHT, NEW FIXTURES TO MATCH EXISTING. NEW (N), EXISTING (E) OR RELOCATED (R), 2'x2', 4 TUBE RECESSED FLUORESCENT LIGHT FIXTURE WITH PARABOLIC LENS, NEW FIXTURES TO MATCH EXISTING, REMOVE EXISTING LIGHT FIXTURE OR RELOCATE EXISTING LIGHT FIXTURE AS SHOWN, RECESSED MR16, 50 WATT, INCANDESCENT LIGHT FIXTURE. NEW RECESSED EMERGENCY LIGHT WITH BATTERY BACK—UP, NEW, EXISTING OR RELOCATED CEILING MOUNTED EXHAUST FAN, SUPPLY AIR DIFFUSER, SEE SHEET A-6, RETURN AIR GRILLE, SEE SHEET A-6, MANUrAU I UKtK JUJrtwutU D«vn LniJuw CEILING 0 8'-0" A.F.F. TO BOTTOM OF SOFFIT, TYPICAL. J........................... . ........ ........... ....... ... ...... .... . .... .............. ..... REFLECTED CEILING PLAN J _T >- 11 m V) z 0 a 0 0 z W E4 E 4 - Q' F--1 O �w O O Z M Lo O T� U �oo I uj V 1 Z = E uo 00 Lu O c) �No r T� o g: r`r/,, N Q � CPQ N c� CONTRACTOR, SHALL -VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. cyO u - t) Z • N c M dao i O Q 3 Q QNB �'� a� cy— w z can N C Q u O N n W C � Z U T O U � 1 7 2 DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT N0, C32479 FILE NAME 2479A4U SHEET A-4 I t, SYSTEM NO. WL1006 (FORMERLY SYSTEM NO. 187) F RATING - 2 HR TRATING -0HR �g SECTION g—g 1' 1. WALL ASSEMBLY -THE FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CIONSTRUCTED OF THE MATERIALS AND IN THE MANNER SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. STEEL STUDS TO BE MIN 2-1/2 IN. WIDE AND SPACED MAX 24 IN. O.C. B. WALLBOARD, GYPSUM* - TWO LAYERS OF NOM 5/8 IN. THICK GYPSUM WALLBOARD, AS SPECIFIED IN THE INDIVIDUAL WALL AND PARTITION DESIGN, MAX. DIAM OF OPENING IS 2 IN. 2. THROUGH PENETRANTS - ONE METLIC PIPE, CONDUIT OR TUBING TO BE CENTERED WITHIN THE FIRESTOP 2. SYSTEM. PIPE, CONDUIT OR TUBING TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY, THE FOLLOWING TYPES AND SIZES OF METALLIC PIPE, CONDUIT OR TUBING MAY BE USED; A. STEEL PIPE - NOM 1 IN. DIAM (OR SMALLER) SCHEDULE 5 (OR HEAVIER) STEEL PIPE. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. B. CONDUIT - NOM 1 IN. DIAM (OR SMALLER) ELECTRICAL METALLIC TUBING OR RIGID STEEL CONDUIT. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. C. COPPER TUBING - NOM 1 IN. DIAM (OR SMALLER) TYPE L (OR HEAVIER) COPPER TUBING. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. D. COPPER PIPE - NOM 1 IN. DIAM (OR SMALLER) REGULAR (OR HEAVIER) COPPER PIPE. A NOM ANNULAR SPACE OF 5/16 IN. IS REQUIRED WITHIN THE FIRESTOP SYSTEM. 3. FIRESTOP SYSTEM - THE FIRESTOP SYSTEM SHALL CONSIST OF THE FOLLOWING: A. FILL, VOID OR CAVITY MATERIAL* - PUTTY - MIN 1-1/2 IN. THICKNESS OF FILL MATERIAL APPLIED WITHIN THE ANNULS, ON BOTH SURFACES OF WALL. ADDITIONAL FILL MATERIAL TO BE INSTALLED SUCH THAT A MIN 1/8 IN. CROWN IS FORMED AROUND THE PENETRATING ITEM, HEVI-DUTY/NELSON UNIT OF GENERAL SIGNAL CORP, - TYPE FSP PUTTY *BEARING THE UL CLASSIFICATION MARKING D�IPEPENETRATION DETAIL T TO SCALE DESIGN N0. U465 NONBEARING WALL RATING -1 HR. 2 3 4 5 2 4 1. FLOOR AND CEILING RUNNERS - (NOT SHOWN) CHANNEL SHAPED RUNNERS, 3-5/8 IN. WIDE (MIN), 1-1/4 IN. LEGS, FORMED FROM N0, 25 MSG (MIN. NO. 20 MSG WHEN ITEM 4C IS USED) GLAV STEEL, ATTACHED TO FLOOR AND CEILING WITH FASTENERS SPACED 24 IN. OC MAX. 3, 2, STEEL STUDS - CHANNEL SHAPED, 3-5/8 IN. WIDE (MIN), 1-1/4 IN. LEGS 3/8 IN, FOLDED BACK RETURNS, FORMED FROM NO. 25 MSG (MIN NO. 20 MSG WHEN ITEM 4C IS USED) GALV STEEL SPACED 24 IN, OC MAX. 3. BATTS AND BLANKETS*- (OPTIONAL) - MINERAL WOOL OR GLASS FIBER BATTS PARTIALLY OR COMPLETELY FILLING STUD CAVITY. SEE BATTS AND BLANKETS (BZJZ) CATEGORY FOR NAMES OF CLASSIFIED COMPANIES. 3A. FIBER SPRAYED* - AS AN ALTERNATE TO BATTS AND BLANKETS (ITEM #3) SPRAY APPLIED CELLULOSE INSULATION MATERIAL. THE FIBER IS APPLIED WITH WATER TO COMPLETELY FILL THE ENCLOSED CAVITY IN ACCORDANCE WITH THE APPLICATION INSTRUCTIONS SUPPLIED WITH THE PRODUCT. NOMINAL DRY DENSITY OF 3.0 LB/CU.FT. U S GREENFIBER L L C- COCOON STABILIZED CELLULOSE INSULATION. * SYSTEM NO. W—L-2088 F RATINGS - 1 AND 2 HR (SEE ITEM 1) T RATINGS - 0, 1 AND 2 HR (SEE ITEM 2) SECTION A—A WALL ASSEMBLY - THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES WALL AND PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING CONSTRUCTON FEATURES: A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. STEEL STUDS TO BE MIN 3-1/2 IN, WIDE AND SPACED MAX 24 IN. O.C. B. WALLBOARD, GYPSUM* - THICKNESS, TYPE, NUMBER OF LAYERS AND FASTENERS AS REQUIRED IN THE INDIVIDUAL WALL AND PARTITION DESIGN, DIAM OF OPENING SHALL BE 7/8 IN, LARGER THAN THE OUTSIDE DIAM OF NONMETALLIC PIPE OR CONDUIT (ITEN 2) THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS EQUAL TO THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. THROUGH PENETRANTS - ONE NONMETALLIC PIPE OR CONDUIT TO BE INSTALLED EITHER CONCENTRICALLY OR ECCENTRICALLY WITHIN THE FIRESTOP SYSTEM. THE ANNULAR SPACE FOR NOM 1-1/4 IN, DIAM AND SMALLER BETWEEN THE PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 0 IN. (POINT CONTACT) TO MAX 7/8 IN. THE ANNULAR SPACE FOR PIPE OR CONDUIT GREATER THAN NOM 1-1/4 IN. DIAM BETWEEN THE PIPE OR CONDUIT AND PERIPHERY OF OPENING SHALL BE MIN 1/2 IN. TO MAX. 1 IN. PIPE OR CONDUIT TO BE RIGIDLY SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY. THE FOLLOWING TYPES AND SIZES OF NONMETALLIC PIPES OR CONDUITS MAY BE USED: A. POLYVINYL CHLORIDE (PVC) PIPE - NOM 2 IN. DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE OR CELLULAR CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEM. B. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 2 IN. DIAM (OR SMALLER) SDR17 CPVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. C. POLYVINYL CHLORIDE (PVC) PIPE - NOM 3 IN. DIAMOR SMALLER) SCHEDULE 40 SOLID CORE PVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY PIPING SYSTEM. D. CHLORINATED POLYVINYL CHLORIDE (CPVC) PIPE - NOM 3 IN. DIAM (OR SMALLER) SDR17 CPVC PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) PIPING SYSTEMS. E. RIGID NONMETALLIC CONDUIT++ - NOM 3 IN. DIAM (OR SMALLER) SCHEDULE 40 PVC CONDUIT INSTALLED IN ACCORDANCE WITH ARTICLE 347 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). F. ELECTRICAL NONMETALLIC TUBING (ENT)++ - NOM 1 IN. DIAM (OR SMALLER) ENT FORMED OF PVC, INSTALLED IN ACCORDANCE WITH ARTICLE 331 OF THE NATIONAL ELECTRICAL CODE (NFPA NO. 70). SEE RIGID NONMETALLIC CONDUIT (DZKT) AND ELECTRICAL NONMETALLIC TUBING (FKHU) IN UL CONSTRUCTION MATERIALS DIRECTORY OR NAMES OF MANUFACTURERS. G. ACRYLONITRILE BUTADIENE STYRENE (ABS) PIPE - NOM 2 IN. DIAM (OR SMALLER) SCHEDULE 40 SOLID CORE OR CELLULAR CORE ABS PIPE FOR USE IN CLOSED (PROCESS OR SUPPLY) OR VENTED (DRAIN, WASTE OR VENT) PIPING SYSTEMS. THE HOURLY T RATING IS DEPENDENT ON THE HOURLY RATING OF THE WALL ASSEMBLY, THE PIIPE OR CONDUIT SIZE AND WHETHER THE PIPE IS INTENDED FOR USE AS A CLOSED OR VENTED SYSTEM, AS SHOWN IN THE FOLLOWING TABLE: NOM PIPE WALL ASSEMBLY CLOSED (C) OR T RATING DIAM IN. RATING HR VENTED (V) HR 1/2 TO 3 1 C 1 1/2 TO 1-1/4 1 V 1 1/2 TO 1-1/4 2 C 2 1/2 TO 1-1/4 2 V 1 2 1 V 0 2 2 V 0 FILL, VOID OR CAVITY MATERIALS* - CAULK OR PUTTY - MIN THICKNESS OF 5/8 IN, AND 1-1/4 INI. OF CAULK OR PUTTY FOR 1 OR 2 HR RATED WALL ASSEMBLIES, RESPECTIBLY, APPLIED WITHIN ANNULUS BETWEEN PIPE OR CONDUIT AND PERIPHERY OF THE OPENING, FLUSH WITH BOTH SURFACES OF WALL ASSEMBLY. AT THE POINT CONTACT LOCATION BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD, A MIN 1/2 IN, DIAM BEAD OF CAULK OR PUTTY SHALL BE APPIED AT THE PIPE OR CONDUIT/WALLBOARD INTERFACE ON BOTH SURFACES OF WALL ASSEMBLY. MINESOTA MINING & MFG CO - CP 25WB+, MPS -2+ ++BEARING THE UL LISTING MARK. *BEARING THE UL CLASSIFICATION MARKING PIPE PENETRATION _D1TAIL 8 NOT TO SCALE 4. WALLBOARD, GYPSUM -5/8 IN. THICK, 4 FT. WIDE, ATTACHED TO STEEL STUDS AND FLOOR AND CEILING TRACK WITH 1 IN. LONG, TYPE S SELF -TAPPING STEEL SCREWS SPACED 8 IN. OC. ALONG 3-5/8" METAL STUDS EDGES OF BOARD AND 12 IN. OC. IN THE FIELD OF THE BOARD. JOINTS ORIENTED VERTICALLY AND @ 48" O.C. BRACE STAGGERED ON OPPOSITE SIDES OF THE ASSEMBLY. WHEN ATTACHED TO ITEM 6 (FURRING CHANNELS), WALL TO BAR JOIST WALLBOARD IS SCREW ATTACHED TO FURRING CHANNELS WITH 1 IN. LONG, TYPE S STEEL SCREWS SPACED 12 IN. OC. BORAL GYPSUM INC. -TYPE BG -C. EXISTING SUSPENDED CANADIAN GYPSUM COMPANY - TYPES AR, C, IP -X2, SCX, SHX, WRC OR WRX. ACOUSTICAL CEILING CONTINENTAL GYPSUM COMPANY - TYPE CG -C. SYSTEM EAGLE -GYPSUM PRODUCTS - TYPE EG -C. G -P GYPSUM CORP. - TYPES 5, 9, C, GPFS6, GPFS-C. NATIONAL GYPSUM CO., CHARLOTTE, NC - TYPES FSK -G, FSW-G. NATIONAL GYPSUM CO., RIYADH, SAUDIA ARABIA - TYPE FR OR WR. R-19 BATT INSULATION PABCO GYPSUM CO. - TYPE PG -C. REPUBLIC GYPSUM CO. - TYPE RG -C, STANDARD GYPSUM CORP. - TYPE SG -C. TEMPLE-INLAND FORREST PRODUCTS CORP. - TYPE TP -5. UNITED STATES GYPSUM CO. - TYPE AR, C, IP -X2, SCX, SHX, WRC OR WRX YESO PANAMERICANO SA de CV - TYPE AR, C, IP -X2, SCX, SHX, WRC OR WRX, WESTROC INDUSTRIES LTD. - TYPE WESTROC FIREBOARD. 4A. WALLBOARD, GYPSUM* - (AS AN ALTERNATE TO ITEM 4) - NOM 3/4 IN. THICK, 4 FT WIDE, INSTALLED AS DESCRIBED IN ITEM 4 WITH SCREW LENGTH INCREASED TO 1-1/4 IN. CANADIAN GYPSUM COMPANY - TYPE AR. i UNITED STATES GYPSUM CO. - TYPE AR. STORE FRONT FRAMING YESO PANAMERICANO SA de CV - TYPE AR. AND GLAZING - KAWNEER 4B. WALLBOARD GYPSUM - (AS AN ALTERNATE TO ITEMS 4 AND 4A) - 5/8 IN. THICK INSTALED TRI -FAB 450 OR EQUAL AS DESCRIBED IN ITEM 4, JOINT COVERING (ITEM 5) NOT REQUIRED.WITH CLEAR FINISH CANADIAN GYPSUM COMPANY - TYPE WSX. o UNITED STATES GYPSUM CO. - TYPE WSX. YESO PANAMERICANO SA de CV - TYPE WSX, o 5. JOINT TAPE AND COMPOUND - VINYL, DRY OR PREMIXED JOINT COMPOUND, APPLIED IN TWO COATS 1/2' GYP. BD. BOTH TO JOINTS AND SCREW HEADS; PAPER TAPE, 2 IN. WIDE, EMBEDDED IN FIRST LAYER OF COMPOUND SIDES OF 3 5/8" (25 OVER ALL JOINTS, AS AN ALTERNATE, NOMINAL 3/32 IN. THICK GYPSUM VENEER PLASTER MAY BIE GA.) METAL STUDS ® 24" APPLIED TO THE ENTIRE SURFACE OF CLASSIFIED VENEER BASEBOARD. JOINTS REINFORCED, O.C. BRACE STUDS AS 6, FURRING CHANNEL - (OPTIONAL -NOT SHOWN) - RESILIENT 25 MSG GALV. STEEL FURRING CHANNELS i REQUIRED BY CODE SPACED VERTICALLY MAX 24 IN. OC, FLANGE PORTION ATTACHED TO EACH INTERSECTING STUD WITH EW CARPET ON 1/2 IN. LONG TYPE S-12 PANHEAD STEEL SCREWS. *BEARING THE UL CLASSIFICATION MARKING. SLAKING CONCRETE TENANT f,.SEPERATION iWALL 6 DETAIL; k. ksPHASE}t y*2 5 WALL SECTION—PH. 3 NOT TO SCALE SCALE 1 /2 EXISTING SUSPENDED ACOUSTICAL CEILING SYSTEM, SYSTEM NO. WL1001 N (FORMERLY SYSTEM NO. 147) VARIES QZ F RATINGS -1,2,3 AND 4 HR (SEE ITEMS 2 AND 3) T RATINGS -0,1,2,3 AND 4 HR (SEE ITEM 3) L RATING AT AMBIENT -LESS THAN 1 CFM/SQ. FT. (SEE ITEM 3) L RATING AT 400 F -LESS THAN 1 CFM/SQ. FT. (SEE ITEM3) SYSTEM NO. WL1017 (FORMERLY F RATING - 1,2 SYSTEM ) HR(SEES TEM3) TRATING -0HR L RATING AT AMBIENT - LESS THAN 1 CFM/SQ FT L RATING AT 400 F - LESS THAN 1 CFM/SQ FT I 4 v 0 Z 3 1C o V) 2 1B A - A SECTION A—A SECTION A—A 1. WALL ASSEMBLY -THE 1,2,3 OR 4 HOUR FIRE -RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CONSTRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SE- 1. WALL ASSEMBLY -THE 1 OR 2 HR FIRE RATED GYPSUM WALLBOARD/STUD WALL ASSEMBLY SHALL BE CON - RIES WALL OR PARTITION DESIGNS IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLL- STRUCTED OF THE MATERIALS AND IN THE MANNER DESCRIBED IN THE INDIVIDUAL U300 OR U400 SERIES z OWING CONSTRUCTION FEATURES; WALL OR PARTITION DESIGN IN THE UL FIRE RESISTANCE DIRECTORY AND SHALL INCLUDE THE FOLLOWING A. STUDS -WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS (MAX 2 H FIRE RATED ASSEMBLIES) OR' CONSTRUCTON FEATURES; o STEEL CHANNEL STUDS. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. A. STUDS - WALL FRAMING MAY CONSIST OF EITHER WOOD STUDS OR STEEL CHANNEL STUDS. WITH NOM 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN, 3-5/8 IN. WOOD STUDS TO CONSIST OF NOM 2 BY 4 IN. LUMBER SPACED 16 IN. O.C. WITH NOMST Q WIDE BY 1-3/8 IN. DEEP CHANNELS SPACED MAX 24 IN. O.C. 2 BY 4 IN. LUMBER END PLATES AND CROSS BRACES. STEEL STUDS TO BE MIN, 3-5/8 IN.WIDE B. WALLBOARD, GYPSUM* -NOM 1/2 OR 5/8 IN. THICK, 4 FT. WIDE WITH SQUARE OR TAPERED EDGES, BY 1-3/8 IN. DEEP CHANNELS SPACED MAX. 24 IN. O.C. W E-+ THE GYPSUM WALLBOARD TYPE, THICKNESS, NUMBER OF LAYERS, FASTENER TYPE AND SHEET ORIENTA- B. WALLBOARD, GYPSUM* - NOM 5/8 IN. THICK, 4 FT, WIDE WITH SQUARE OR TAPERED EDGES. THE o E� ATION SHALL BE AS SPECIFIED IN THE INDIVIDUAL U300 OR U400 SERIES DESIGN IN THE UL FIRE RES- GYPSUM WALLBOARD TYPE, NUMBER OF LAYERS, AND SHEET ORIENTATION SHALL BE AS SPECIFIED �+ ISTANCE DIRECTORY, MAX DIAM OF OPENING IS 13-1/2 IN. IN THE INDIVIDUA-L WALL OR PARTITION DESIGN. DIAM OF CIRCULAR CUT THROUGH GYPSUM WALL- o F ­Io 2. PIPE OR CONDUIT -NOM 12 IN. DIAM (OR SMALLER) SCHEDULE 10 OR HEAVIER) STEEL PIPE, NOM 6 IN. BOARD ON EACH SIDE OF WALL ASSEMBLY TO BE MIN, 0 IN. (POINT CONTACT) TO MAX 1 IN. Q DIAM (OR SMALLER) STEEL CONDUIT, NOM 4 IN. DIAM (OR SMALLER STEEL ELECTRICAL METALLIC TUBING OR LARGER THAN OUTSIDE DIAM OF FLEXIBLE METAL CONDUIT (ITEM 2) INSTALLED IN THROUGH OPEN- TYPE L OR (OR HEAVIER) COPPER TUBING OR NOM 1 IN. DIAM (OR SMALLER) FLEXIBLE STEEL CONDUIT. ING. SIDE EDGE OF CIRCULAR OPENING TO BE MIN. 3 IN. FROM NEAREST STUD IN WALL CAVITY.Z N ® rCe)) WHEN COPPER PIPE OR FLEXIBLE STEEL CONDUIT IS USED, MAX F RATING OF FIRESTOP SYSTEM (ITEM3) _ 0 IS 2 H. STEEL PIPE OR CONDUITS LARGER THAN NOM 4 IN. DIAM MAY ONLY BE USED IN WALLS CONSTR- C. FASTENERS WHEN WOOD STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTACHED TO STUDS Q U)o J ao o WITH CEMENT COATED NAILS AS SPECIFIED IN THE INDIVISUAL WALL OR PARTITION DESIGN. WHEN Z UCTED USING STEEL CHANNEL STUDS. A MAX OF ONE PIPE OR CONDUIT IS PERMITTED IN THE FIRESTOP U� �-+= w o Lo °O STEEL CHANNEL STUD FRAMING IS EMPLOYED, GYPSUM WALLBOARD ATTCHED TO STUDS WITH TYPE S SYSTEM. PIPE OR CONDUIT TO BE INSTALLED NEAR CENTER OF STUD CAVITY WIDTH AND TO BE RIGIDLY SUP- n � °O PORTED ON BOTH SIDES OF WALL ASSEMBLY. SELF -DRILLING, SELF -TAPPING BULGE -HEAD STEEL SCREWS AS SPECIFIED IN THE INDIVISUAL WALL Qlj 3 N o 3. FILL, VOID OR CAVITY MATERIAL* - CAULK -CAULK FILL MATERIAL INSTALLED TO COMPLETELY FILL ANNULAR OR PARTITION DESIGN. P -SMALLER)L o z - .1 SPACE BETWEEN PIPE OR CONDUIT AND GYPSUM WALLBOARD AND WITH A MIN 1/4 IN, DIAM. BEAD OF CAULK 2. THROUGH PENETRANTING PRODUCT* - FLEXIBLE METAL CONDUIT NOM 4 IN. DIAM (OR 3 � N APPLIED TO PERIMETER OF PIPE OF CONDUIT AT ITS EGRESS FROM THE WALL. CAULK INSTALLED SYMETRICA- ALUMINUM OR STEEL FLEXIBLE METAL CONDUIT+. MAX ONE FLEXIBLE METAL CONDUIT TO BE INSTALLED LLY ON BOTH SIDES OF WALL ASSEMBLY. THE HOURLY F RATING OF THE FIRESTOP SYSTEM IS DEPENDENT NEAR CENTER OF CIRCULAR OPENING IN GYPSUM WALLBOARD. FLEXIBLE METAL CONDUIT TO BE RIGIDLY W UPON THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED. AS SHOWN IN THE SUPPORTED ON BOTH SIDES OF WALL ASSEMBLY, o H FOLLOWING TABLE. THE HOURLY T RATING OF THE FIRESTOP SYSTEM IS DEPENDENT UPON THE TYPE OR SIZE AFC CABLE SYSTEMS INC. Q la -z x OF THE PIPE OR CONDUIT AND THE HOURLY FIRE RATING OF THE WALL ASSEMBLY IN WHICH IT IS INSTALLED, 3. FILL, VOID OR CAVITY MATERIAL* - CAULK - CAULK FILL MATERIAL FORCED INTO ANNULAR SPACE AROUND ry u AS TABULATED BELOW: ENTIRE CIRCUMFERENCE OF THROUGH PENETRATING PRODUCT TO COMPLETELY FILL OPENING IN GYPSUM MAX PIP ANNULAR F T WALLBOARD LAYERS ON EACH SIDE OF THE WALL ASSSEMBLY, A MIN 5/8 IN. THICKNESS OF CAULK IS OR CONDUIT SPACE, RATING RATING REQUIRED FOR THE 1 HR. F RATING, A MIN. 1-1/4 IN THICKNESS OF CAULK IS REQUIRED FOR 2 F o DIAM, IN. IN. HR. HR. RATING, 1 0 TO 3/16 1 OR 2 0+, 1 OR 2 MINNESOTA MINING & MFG CO - CP 25WB+ 1 1/4 TO 1/2 3 OR 4 3 OR 4 *BEARING THE UL CLASSIFICATION MARKING 4 0 TO 1/4 1 OR 2 0 6 1/4 TO 1/2 3 OR 4 0 PIPE PENETRATION DETAILcn 12 3/16 TO 3/8 1 OR 2 0 1 O NOT TO SCALE E +WHEN COPPER PIPE IS USED, T RATING IS 0 H. -' o MINNESOTA MINING & MFG. CO.- TYPES CP -25 S/L, CP -25 N/S, CP -25 WB, CP -25 WB+. (NOTE; L RATINGS APPLY ONLY WHEN TYPE CP -25 WB+ CAULK IS USED.) EXIST. 5/8" TYPE "X" CUT IN BOX - 2G �_ hj *BEARING THE UL CLASSIFICATION MARKING GYP. BD. ® BOTH ® 24" A.F.F. SIDES OF STUDS CONDUIT PENETRATION DETAIL y `� AVT_TO SCALE U EXIST, 6" L 4" SQ. BOX CONTRACTOR SHALL VERIFY META'_ STUDS ® 18" A.F,F. ALL CONDITIONS --ANDY DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, WRAP BOTH BOXES INSIDE THE EXIST. FIRE WALL ( 1 HR, RATED) W/ OMISSIONS OR DISCREPANCIES FIRE RETARDANT PUTTY PADS COMPLETELY COVERING BOXES AND 3" OF Q BEFORE BEGINING OR FABRICATING ANY WORK. CONDUIT. SEE UL DESIGN (CLIV) WALL OPENING PROTECTIVE MATERIALS, o DO NOT SCALE DRAWINGS. cnz ELECTRICAL BOX PENETRATION DETAIL Q 11 SCALE; 1 = 1 -0 ELEC-PENETRATION o U LL_ EXISTING METAL BUILDING 3-5/8" METAL STUDS ® 48" O.C. BRACE WALL TO BAR JOIST 8d Z a o EXISTING SUSPENDED NEW R-19 BATT INSULATION FULL O HEIGHT AT WAREHOUSE ONLY. ACOUSTICAL CEILING NEW R-19 BATT NEW R-19 BATT � p__Q N SYSTEM INSULATION INSULATION NEW R-19 CEILING BATT, Q i d INSULATION '` W a o 0 , rnr000000000 F00000000 00000000100000010000 00000000000 o LLJ ® �--- w z C � N fn Q EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE LAY -IN SYSTEM iE < a � Q -19 BATF ,,, EXIST. OR NEW 2' X 4' w O INSULATION EXIST. 2' X 4' SUSPENDED � J ACOUSTICAL TILE LAY -IN SUSPENDED ACOUSTICAL TILELij SYSTEM o LAY -IN SYSTEM z 5/8" TYPE "X" GYP. BD. z a Z W w BOTH SIDES OF EXISTING w Z FULL BATT INSULATION IN FULL BATT INSULATION IN 6" METAL STUDS ® 24" RESTROOM PARTITIONS ONLY o RESTROOM PARTITIONS ONLY o O.C. - 1 HR. TENANT o o FOR SOUND CONTROL o FOR SOUND CONTROL o SEPARATION WALL. PROVIDE o o C) BRACING AND BLOCKING C) m AS REQUIRED BY CODE. m 1/2" GYP. BD. BOTH SIDES o 1 /2" GYP. BD. BOTH SIDES OF o 0 STORE FRONT FRAMING OF 6 METAL STUDS 0 24 AND GLAZING - KAWNEER " '� 0 3 5/8" METAL STUDS 0 24" o OOF STRUCTURE HEIGHT E N O.C. BRACING AND BLOCKING VARIES QZ • Q SEAL WALL TO ROOF DECK WITH o N FIRE RATED CAULK (PROVIDE FIRE RATED BACKING AS REQUIRED) Q a- a WALL TO BAR JOIST 8d Z a o EXISTING SUSPENDED NEW R-19 BATT INSULATION FULL O HEIGHT AT WAREHOUSE ONLY. ACOUSTICAL CEILING NEW R-19 BATT NEW R-19 BATT � p__Q N SYSTEM INSULATION INSULATION NEW R-19 CEILING BATT, Q i d INSULATION '` W a o 0 , rnr000000000 F00000000 00000000100000010000 00000000000 o LLJ ® �--- w z C � N fn Q EXIST. 2' X 4' SUSPENDED ACOUSTICAL TILE LAY -IN SYSTEM iE < a � Q -19 BATF ,,, EXIST. OR NEW 2' X 4' w O INSULATION EXIST. 2' X 4' SUSPENDED � J ACOUSTICAL TILE LAY -IN SUSPENDED ACOUSTICAL TILELij SYSTEM o LAY -IN SYSTEM z 5/8" TYPE "X" GYP. BD. z a Z W w BOTH SIDES OF EXISTING w Z FULL BATT INSULATION IN FULL BATT INSULATION IN 6" METAL STUDS ® 24" RESTROOM PARTITIONS ONLY o RESTROOM PARTITIONS ONLY o O.C. - 1 HR. TENANT o o FOR SOUND CONTROL o FOR SOUND CONTROL o SEPARATION WALL. PROVIDE o o C) BRACING AND BLOCKING C) m AS REQUIRED BY CODE. m 1/2" GYP. BD. BOTH SIDES o 1 /2" GYP. BD. BOTH SIDES OF o 0 STORE FRONT FRAMING OF 6 METAL STUDS 0 24 AND GLAZING - KAWNEER " '� 0 3 5/8" METAL STUDS 0 24" o WALL SECTION— PH. 3 SCALE 1/2" = 1'-0" z t -A 1/2" = 1-0" r= t OtS LELE 1L/2" .PHAS_E 221 11STENANT.T,SE SCALE 1/2" = V-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A-5 SHEET A-5 TRI -FAB 450 OR EQUAL O.C. BRACING AND BLOCKING O.C. BRACING AND BLOCKING o 0 WITH CLEAR FINISH AS REQUIRED BY CODE. CD AS REQUIRED BY CODE. o NEW R-19 BATT INSULATION - TO 10'-0" HIGH 0 OFFICES, a Q) VINYL WALL BASE - BOTH SIDES OF WALL o em EW CARPET ON EXISTING VINYL WALL BASE VINYL WALL BASE XISTING CONCRETE 0 N i CONCRETE SLAB EXISTING CONCRETE SLAB EXISTING CONCRETE SLAB SLAB O FINISH PER SCHEDULE FINISH PER SCHEDULE 0 UL DESIGNk; N0. U465 - 1 HOUR RATED WALL SECTION— PH. 3 SCALE 1/2" = 1'-0" z t -A 1/2" = 1-0" r= t OtS LELE 1L/2" .PHAS_E 221 11STENANT.T,SE SCALE 1/2" = V-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A-5 SHEET A-5 EXIST. EXHAUST FAN EF -1 (RESTROOMS) 100 CFM (2 CFM/S.F.) 2.5 SONES NOTES .25 STATIC BACKDRAFT DAMPER BROAN 5C189 MECHANICAL NOTES: 1. FLEXIBLE DUCTS OF NOT MORE THAN 10 FEET IN LENGTH MAY BE USED TO CONNECT SUPPLY, RETURN OR EXHAUST AIR TERMINAL DEVICES TO RIGID DUCT SYSTEMS. 2. THERMAL OR ACOUSTICAL LINING MATERIALS SHALL NOT BE INSTALLED WITHIN DUCTS, TERMINAL BOXES, SOUND TRAPS AND OTHER IN -DUCT SYSTEMS SERVING AREAS SUCH AS OPERATING, DELIVERY AND RECOVERY ROOMS, NURSERIES, INTENSIVE CARE UNITS AND NEGATIVE PRESSURE ISOLATION ROOMS UNLESS TERMINAL FILTERS WITH 90 PERCENT EFFICIENCY ARE INSTALLED DOWNSTREAM OF THE DUCT LINING, HVAC PLAN SYMBOLS LEGEND SYMBOL QTY DESCRIPTION MOUNTING MANUFACTURER & CATALOG REMARKS NOTES 24 X24 FACE SIZE W/ 12 NOMINAL NECK SIZE AIR SUPPLY GRILLE RECESSED TITUS MODEL TMS CLEAN AND PAINT ALL EXIST, DIFFUSERS TO MATCH EXIST, 1,2 CEILING TILE. ADD INSULATION BLANKETS ABOVE DIFFUSER 24X48 OR 24 X 24 FACE SIZE AIR RETURN GRILLE RECESSED TITUS MODEL 50-F CLEAN AND PAINT ALL EXIST. DIFFUSERS TO MATCH EXIST. 1,2 CEILING TILE, ADD INSULATION BLANKETS ABOVE DIFFUSER BUILDING STANDARD RECESSED IMATCH EXISTING INSTALL NEW 6" DIA. GALV. METAL DUCT TO EXISTING 1,2 EXHAUST GRILLE/FAN ROOF PENETRATION. O THERMOSTAT WALL MOUNTED REMOVE, CLEAN AND REMOUNT OVER NEW WALL FINISH HVAC SYMBOLS LEGEND NOTES: 1. 'N' NOTATION NEXT TO AN HVAC FIXTURE INDICATES THAT CONITRACTOR IS TO PROVIDE A NEW HVAC FIXTURE AS SPECIFIED IN THE HVAC SYMBOLS LEGEND, 2. 'R' NOTATION NEXT TO AN HVAC FIXTURE INDICATES THAT CONTRACTOR IS TO RELOCATE AN HVAC FIXTURE AS SHOWN ON THE REFLECTED CEILING PLAN. 3. DIFFUSERS / GRILLES WITHOUT DESIGNATIONS INDICATES EXISTIING BUILDING STANDARD DIFFUSER / GRILLE TO REMAIN IN EXISTING POSITION. R-6 FILE) DUCT W01 2" METAL STRAPPIN, 2x2 "PER. NECK ON ROOF 3"0 GALV. METAL DUCT TO ROOF BATHROOM EXHAUST FAN CFM PER SQUARE FOOT IrW/ "ZERO" BACK DRAFT DAMPER NOTE: MAKE UP AIR FOR NEW RESTROOM IS BY UNDERCUT DOOR AND THE AC SUPPLY. MAKE-UP AIR IS TO BE EQUIVALENT TO AIR EXHAUSTED. 3EXHAUST DETAIL NOT TO SCALE HVACD05H,DWG NOTE: ALL DUCT WORK TO BE SUPPORTED TO SMACNA AND TIMA STANDARDS BEADED WIRE OR 2" STRAPPING ® 48" O.C. R-6 FLEXR 2" METAL DUCT WORK STRAPPING 48 0. C. 2FLE�(QU CTDETAIL NOT TO SCALE HVACD04H.DWG NOTE: ALL DUCT WORK TO BE _SUPPORTED TO JA AN[ ARDS WIRE I NOTE: PER 2001 FLORIDA MECHANICAL CODE, SEAL ALL SEAMS AND CONNECTIONS WITH 181 UL APPROVED ALUMINUM TAPE. DUCT WORK } 1 NOT TO SCALE HVACD01H.DWG F NEW 24x48 RETURN AIR DUCT TO BE ' CONNECTED TO EXISTING RETURN AIRji PLENUM /i ✓ ; , i/ ✓i' j " / / 7 f / 1xi To i J R FOR 6 ✓/rr / �� r / ♦/ � of ` ,yr ,' � : � #/ ,i � f'`" f J ° fJ'"'p J ✓' i' ✓F\ —� j}J �J/ , / / i / `` i Oma' ✓ ;, f -!:%' -'' J '` // / ✓Tk .J.. O Jf O ✓ /ice r J ♦` :: I J`i'J' J ' r: /%// •J'` / �F//i \\iiJ/ pi/ jr r/ O. Jj' J � ,:! ,O fr •/,. `'�.' /J J , � „ yr /" ,. J/ / • i' < J /i / lam.♦ ��� '� O+tp/ r ✓ ,/ / o J Jar,, O ` f r fir f ✓�;. NEW 2448 RETURN AIR DUCT TO BE CONNECTED TO EXISTING RETURN AIR PLENUM / J .:::...:::.::»»...».....:....:.:...................:..........:..........................»:.:.:..:....:.....�............:.......... ........... ::..... :. o \ J a SCALE: 3/16" = 1'-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO, C32479 FILE NAME 2479A6U SHEET A-6 0 L 0 � V 1 r V w r C `^' O U 0 'O O 'u\ cl:� rl J1 O ® o J M Q a d J O Q c) U) % ^Q Ln 00 w OJ r- N �1 w Q" � cn o Z ( --4 o o � 0 Q CL o � 22 0 j 0 c�J v - o o � i N............. j U � N N L ,r N CONTRACTQR SHALL -VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. L L I o .. o � Q C) LjU C N y� V O S NU Q Z • 0 N �V M Z �¢M �Q i"Q� Q N W L ��a ® Q ¢ cn N Q c� V V E L j a o � o V O F v o ,0 T 0 V � Q O L Q *Q SCALE: 3/16" = V-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A7U SHEET - 7 m N Z O _N LLJ a 0 d 1 Z � L I Li 0 L 0 � V 1 r V w r C `^' O U 0 'O O 'u\ cl:� rl J1 O ® o J M Q a d J O Q c) U) % ^Q Ln 00 w OJ r- N �1 w Q" � cn o Z ( --4 o o � 0 Q CL o � 22 0 j 0 c�J v - o o � i N............. j U � N N L ,r N CONTRACTQR SHALL -VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. L L I o .. o � Q C) LjU C N y� V O S NU Q Z • 0 N �V M Z �¢M �Q i"Q� Q N W L ��a ® Q ¢ cn N Q c� V V E L j a o � o V O F v o ,0 T 0 V � Q O L Q *Q SCALE: 3/16" = V-0" DRAWN BJ, PH CHECKED JRJJ DATE 03/28/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A7U SHEET - 7 ROOM FINISH SCHEDULE ROOM FLOOR BASE WALLS CEILING HEIGHT ENTRY CARPET WOOD PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" SHOWROOM CARPET WOOD PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" SHOP CARPET 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #3 CARPET WOOD PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #4 CARPET WOOD PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" HALL #2 CARPET WOOD PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" NEW RESTROOM EXIST. EXIST, EXIST. ONE (1) EXIST. ACOUST./GRID 10'-0" BREAK ROOM VINYL 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #2 CARPET 4" VINYL PAINT ALL WALLS NEW ACOUST./GRID 10'-0" HALL #1 VINYL 4" VINYL PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" OFFICE #1 CARPET 4" VINYL PAINT ALL WALLS NEW ACOUST./GRID 1 O'-0" ELEC, ROOM VINYL 4" VINYL PAINT ALL WALLS NEW ACOUST./GRID 10'-0" EXIST. MEN EXIST. EXIST. PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" EXIST. WOMEN EXIST, EXIST. PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" EXIST. VEST, EXIST. EXIST. PAINT ALL WALLS EXIST. ACOUST./GRID 10'-0" FINISH NOTES VINYL AND CARPET FLOORING VINYL OR CARPET FLOORING IS TO BE SELECTED BY OWNER OR TENANT, INTERIOR FINISH REQUIREMENTS: MINIMUM FLAMESPREAD CLASSIFICATIONS: EXITS - CLASS B. - FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450. EXITS ACCESS - CLASS B.- FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450, WALL MOUNTED OTHER SPACES - CLASS C,- FLAMESPREAD 76-200, SMOKE DEVELOPED 0-450. TRANSPARENCY BY OTHERS— WALL MOUNTED TRANSPARENCY BY OTHERS DOOR SCHEDULE GENERAL CONTRACTOR TO PROVIDE AND INSTALL ALL FLOORING. WOOD BASE SEE WALL SECTIONS 4 &.5/A-5 FOR SPECIFICATION. ONE (1) COAT m m PRIMER PLUS ONE (1) COAT PAINT (SEMI -GLOSS FINISH). AS NOTED PROJECT NO. WOOD CHAIR RAIL SEE WALL SECTIONS, 4 & 5/A-5 FOR SPECIFICATION. ONE (1) COAT STILE 4 PRIMER PLUS ONE (1) COAT PAINT (SEMI -GLOSS FINISH). VINYL BASE 4" BASE SELECTED BY OWNER OR TENANT, GENERAL CONTRACTOR TO STILE 4 ° PROVIDE AND INSTALL VINYL BASE. WALL PAINT ONE (1) COAT PRIMER PLUS ONE (1) COAT PAINT (SEMI -GLOSS g FINISH), TRANSPARENCY CEILING TILE & GRID NEW 2' x 4' BUILDNG STANDARD SYSTEM. NEW WOOD DOORS ONE (1) COAT SANDING SEALER PLUS ONE (1) COAT SEMI -GLOSS URETHANE. NEW METAL DOORS & FRAMES ONE (1) COAT PRIMER PLUS ONE (1) COAT SEMI -GLOSS. INTERIOR FINISH REQUIREMENTS: MINIMUM FLAMESPREAD CLASSIFICATIONS: EXITS - CLASS B. - FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450. EXITS ACCESS - CLASS B.- FLAMESPREAD 26-75, SMOKE DEVELOPED 0-450, WALL MOUNTED OTHER SPACES - CLASS C,- FLAMESPREAD 76-200, SMOKE DEVELOPED 0-450. TRANSPARENCY BY OTHERS— WALL MOUNTED TRANSPARENCY BY OTHERS DOOR SCHEDULE BJ, PH CHECKED JRJJ m m # SIZE THK. MATERIAL FRAME TYPE REMARKS HARDWARE AS NOTED PROJECT NO. 00 3'-6" x 7'-0" 1-3/4" METAL/GLASS METAL STOREFRONT AFn KAWNEER 500 WIDE STILE 4 SHEET a : 3'-6" X 7'-0" 1-3/4" METAL/GLASS METAL STOREFRONT KAWNEER 500 WIDE STILE 4 ° WALL MOUNTED g TRANSPARENCY V) 3. 3'-0" X 6'-8" 1-3 4' WD GLASS WOOD FRENCH / INTERIOR DOOR 1 BY OTHERS z 4. 3'-0" X 6'-8" 1-3/4" WD/GLASS WOOD FRENCH INTERIOR DOOR 2 o 5. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE Q 5 N 6. 3'-0" X 6'-8" 1-3/4" WOOD METAL FLUSH SOLID CORE 1 7. 2'-0" X 6'-8" 1-3/4 WOOD METAL FLUSH SOLID CORE 2 ee Q 8, 3'-6" X''''6'1-3/4' WOOD METALFLUSH SOLID CORE 1 EXISTING Z V) STEEL E1. 3'-0" x 7'-0" 1-3/4" EXIST. METAL EXIST. FLUSH EXIST, EXTERIOR 3 DASHED LINE COLUMN f a ,> " �� E2. 3'- 0 x 6 -8 1-3/4 EXIST. WOOD EXIST. FLUSH EXIST. INTERIOR EXIST. DISPLAY CASES BY OTHERS ,.-' ,-Y' REPRESENTS LIMITS Z U LL_ o OF WOOD CHAIR RAIL o DOOR NOTES: (PROVIDE HARDWARE AS SPECIFIED OR EQUAL TO) ,-'O V) SEE DETAIL 12/A-5 �y '' 0 � � 1. ALL NEW WOOD DOORS ARE TO BE STAIN GRADE BIRCH, CL- o Q 2. LOCKING DEVICES ON REQUIRED EXIT WAY DOORS SHALL NOT REQUIRE THE USE OF 0 A KEY FOR OPERATION FROM INSIDE THE BUILDING, 0 3. DOOR LOCKSETS/PASSAGE SETS ARE TO BE RUSSWIN WITH LEVER ACTION HANDLES. KEYED TO MASTER. o 4. CONTRACTOR IS TO ADJUST ALL DOORS TO NORMAL WORKING OPERATION WHICH INCLUDES THE \ ' - '� DISPLAY CASES BY OTHERS REPAIR OR REPLACEMENT OF HARDWARE AND WEATHER STRIPPING AS REQUIRED. \ Z FcV 5. UNDER CUT INTERIOR DOORS 1/2," \ `� GROUP #1 1-1/2 PR. BUTTS FBB 179 4-1/2 X 4-1/2 \ A-5 DASHED LINE 1 LOCKSET RUSSWIN 2-3/4" BSXASA \ \ '�'- REPRESENTS LIMITS 1 WALL MOUNTED DOOR STOP IVEY \ 03 OF WOOD CHAIR RAIL. GROUP 2 \ \ 1 \\ SEE DETAIL 12/A-5 1-1/2 PR. BUTTS FBB 179 4-1/2 X 4-1/2 \ \ 2 \\ 4 1 PASSAGE SET RUSSWIN 2-3/4" BSXASA \ \ \ 1 WALL MOUNTED DOOR STOP IVEY \ \ A-5 GROUP 1-1/2 PR. BUTTS EXISTING '" \ \ �. �`� SHOW CASES 1 LOCKSET EXISTING \ \ �`� ,% (BY OTHERS) 3 NEW SLIDE BOLTS FULL WIDTH OF DOOR AUTOMATIC WITH TIME DELAY \ \ \\ GROUP #4 \ \ 4 1-1/2 PR. BUTTS FBB 199 4-1/2 X 4-1/2 \ \ = A-5 1 PANIC DEVICE DOR-O-MATIC 1590 "CO SIDE \ \ ��-- TRANSPARENCY DISPLAY 1 PULL HANDLE KAWNEER STYLE -12" @ EXTERIOR \ \ tO BY OTHERS 1 LATCH LOCK ADAMS RITE 4510 \ \ \ `Q---_—=--- 1 ELECTRIC STRIKE ADAMS RITE 7130 ------------ 1 THRESHOLD KAWNEER BUTT HUNG EXISTING STOREFRONT 1 CLOSER LCN 4041 SUPER SMOOTHEE \ O (- GROUP #5 \ \ 11 -7 ' , 1-1/2 PR. BUTTS 21 FBB 199 4-1/2 X 4-1/2 \ \ 1 PANIC DEVICE DOR-O-MATIC 1590 OR EQUAL \ 1 PULL HANDLE/LEVER RUSSWIN 1 LATCH LOCK RUSSWIN 1 ELECTRIC STRIKE RUSSWIN ---------------------- 1 CLOSER LCN 4041 SUPER SMOOTHEE 0 0 w wU Qi o � U CL 1--1 o ® 0 g C `n o Q J O Q c) � rwoJ 000 �I w = �` c) 3V)0 Q o CJ p 'J v N Q 0 W EN -4 0-40 1 Q x C Q U o � 0 0 a o CONTRACTOR -SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. o .. 0 0 U IIS V � r ^ U v Q Z C,7 0 o Q Z ¢ CL a o Q zq N� C) a o W Q o M CL W ® I— w z Q 0� Q V CQ CL Q O U W Q � � Z U o ,a� o CLCL0 RIM � o o L 0 N CD 0 U FLOOR PLAN SCALE: 3/16" = 1'-0" DRAWN BJ, PH CHECKED JRJJ m m m SCALE AS NOTED PROJECT NO. 00 FILE NAME 2479A2U SHEET a g V) a z o N o D_ ee Z V) o V„ a Z U LL_ o o V) � � o CL- o Q 0 0 o Lo- Z FcV 0 0 w wU Qi o � U CL 1--1 o ® 0 g C `n o Q J O Q c) � rwoJ 000 �I w = �` c) 3V)0 Q o CJ p 'J v N Q 0 W EN -4 0-40 1 Q x C Q U o � 0 0 a o CONTRACTOR -SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE JOB SITE AND NOTIFY THE ARCHITECT OF ANY DIMENSIONAL ERRORS, OMISSIONS OR DISCREPANCIES BEFORE BEGINING OR FABRICATING ANY WORK. DO NOT SCALE DRAWINGS. o .. 0 0 U IIS V � r ^ U v Q Z C,7 0 o Q Z ¢ CL a o Q zq N� C) a o W Q o M CL W ® I— w z Q 0� Q V CQ CL Q O U W Q � � Z U o ,a� o CLCL0 RIM � o o L 0 N CD 0 U FLOOR PLAN SCALE: 3/16" = 1'-0" DRAWN BJ, PH CHECKED JRJJ DATE 04/01/03 SCALE AS NOTED PROJECT NO. C32479 FILE NAME 2479A2U SHEET A-2