3121 Orlando Dr - BC02-000184 (KASH N KARRY FOOD STORE) (INTERIOR REMODEL) (A)SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Bos 1788, Sanford, Fl. 32772 (407 302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 Plans Review Sheet Date: October 29, 2001 Business Address: 3121 S. Orlando Drive Occ. Ch.25 Business Name: KASH N' KARRY FOOD STORES Ph. (727) 573-3612 FAX. (727) 573-7734 Contractor: Chrigtiano Const. Co. Ph. (727) 573-3612 FAX (727) 573-7734 Reviewed Re e..ed with", %Mm ] Rejected Reviewed by: Timothy Robles, Fire Protection Inspector Comment: Application accepted as renovation ofstore fagade & interior fixture replacement. Application — If fire alarm panel is going to be relocated, low voltage permit, and plans of scope of'work required by a certified alarm contractor • Permit required if fire alarm is going to be replaced 9 If more than 12 fire sprinkler heads are going to be replaced, and (or) relocated please have fire sprinkler contractor submit plans for permitting 1 SANFORD FIRE DEPARTMENT FIRE PREVENTION DIVISION 300 N. Park Ave., Sanford, Fl. 32771 / P. O. Box 1788, Sanford, Fl. 32772 (407302-2520 / FAX (407) 330-5677 Pager (407) 918-0395 • Existing location of fire extinguisher, and type of fire extinguishers may be required additional fire extinguishers per NEP.A. #10 • Post address on front of building in large numbers, contrast in color t o building color (see blueprints, see #A-3) • Permits for mechanical duct hanger will require certified contractor to submit drawings 2 i 4j RECEIVED KASH N KARRY FOOD STORE INC. s� nz, 26 zoa;T � l(ASH NKARRY # 1890 API PROJECT N0. 9949.01 3121 ORLANDO DRIVE SANFORD, FLORIDA. 32771, ARCHITICTURI [US n ArchitecturePlus International 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813.281.9292 E -Mail api@architectureplus.com INTERNATIONALLicense#AAC001935 OWNER ARCHITECT STRUCTURAL CONSULTANT PLUMBING CONSULTANTS FOOD LION, INC. ARCH ITECTUREPLUS INTERNATIONAL McCARTHY & ASSOCIATES, INC. ENGINEERING PROFESSIONALS, INC. P.O. BOX 1330 2709 ROCKY POINT DRIVE 2555 NURSERY ROAD, SUITE 101 1720 W. CLEAVELAND STREET, SUITE E SALISBURY, NC 28145 SUITE 201 CLEARWATER, FLORIDA 34624-3080 TAMPA, FLORIDA 33605 (704) 633-8250 TAMPA, FLORIDA 33607 (727) 536-8772 (813) 251-6848 (813) 281-9299 CONTACT: CHUCK MORSE CONTACT: PETER HOGG CONTACT: MIKE McCARTHY CONTACT: GARY STENLUND, P.E. BOB SELINSKY -� �-- MUS'f r11 �:E-�W.., LO SDA MECHANICAL CONSULTANT ELECTRICAL CONSULTANT ACCESSIBILITY CODES,i BOWERS CONSULTING CHEHAYEB & ASSOCIATES MUST MEET FLORIDA ENGINEERING 3702 AZEELE STREET ENERGY CODES 1425 JAKE ALEXANDER BLVD. TAMPA, FLORIDA 33609 ------- -- -- sA"FORC1 aUILOING DEpT THESE PLANS ACCEP'rEU FUF F'ER+.11T. Iq P=RMINO SUCEJ t:rT1 TRUE[) 'r0 E3[ A SOUTH SUITE B (813 876-14 5 City of Sanford +;_ �,,p"U LICENS^ C.11lCEL, a TErniUr AS AUT'H o pROCEEO WfTH SALISBURY, N C 28146 Model Codes in effect: c lit3lUtJs a R _ To VIO Standard Building Code 1997 ed. ' -,NCE Ur?r .t„F _' � HnIC � AS, ANY aFLT [?r: p? FRO L}tr.11 r "'EV-_' UDEs. No7q gp�N (704) 630-0075 Standard Plumbing Code 1997 ed. T+pN pF E ;r�EAFrca RE��rnie n co Standard Mechanical Echanical Code 1997 ed. )R pTHEri vl LATIONS pF ►GOING National Electrical Code 1996 ed. Trl SHE C S' CONSTRUCT ON CONTACT: MIKE BOWERS CONTACT: SOUHEIL CHEHAYEB See City Code AMENDMENTS FL. Accessibility Codes 1997 FL. E'!':) Qy C d2 '1297 ISSUED FOR BID/PERMIT SET NO. ISSUE DATE: 9/06/01 OFFICE CRY PEMMIT '� s • ARCHIT[CTURI IU5 INTERN ATI0 NAL 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281,9299 Fax 813281,9292 E—Mail api@architecturep us.com License #AAC001935 F K ash Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- I" FUTURA (ON DENSE D API LOGO BACKGROUND REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC_ #50985 LIGHT (PMS 281 U) (PMS 281 U) (ICIPAINT- EGRET) A F (CONTINUED) p 8' 0" PLAN REVIEW JURISDICTION: CITY Or- SANFORD AB ANCHOR BOLT ABV ABOVE FLR FLUOR FLOOR OA OVERALL. FLUORESCENT OC ON CENTER `�.ancoo"'� 4" FUTURA CONDENSED /Tampa, Florida LIGHT(PMS281U) ACT ACOUSTICAL CEILING TILE PO FINISHED OPENING OD OUTSIDE DIAMETER STANDARD BUILDING CODE (I1BS7) 813.281.9299 4" FUTURA CONDENSED ADJ ADJUSTABLE FP FIREPROOF( ING) OH OVERHEAD k6ledure REGULAR (PMS 2Bl U) AFF ABOVE FINISHED FLOOR FRM FT FRAME OPP HAND OPPOSITE HAND FEET/FOOT STANDARD PLUMBING CODE (11BS4) o heri Wiin 2" FUTURA CONDENSED AHU AIR HANDLING UNIT OPNG OPENING Store Manning REGULAR (PMS 281 U) ALT ALTERNATE FTG FOOTING OPP OPP051TE _ RetaiWgn ALUM ALUMINUM PUT FUTUREP STANDARD MECH AN I CAL CODE (1 SSi I Food Retuning APPROX APPROXIMATE I1 I L I U Il L I U) Padraging ARCH ARCHITECT(URE) (URAL) G NAT I ONAL ELECTR I C COPS C 1SS�o � I N '1 L R N A T 10 N A L Graphics 3" FLAT SCREWS @ 6" O.C. . AUX AUXILIARY PL PROPERTY LINE f (PAINTED) AVG AVERAGE GA GALV GAGE/GAUGE PLAM PLASTIC LAMINATE GALVANIZEID PLAS PLASTIC LICE aA1=ETY CODE Ni�A IP1 C199i) LOGOTYPE RUIELINE 4X4X9'0"P.T.WDPOSTS B GB GRAB BAR. PLYWD PLYWOOD AND ALL Ai=PL (CABLE NFf=A CODE5 (PMS 281 U) (PMS 281 U) (PMS 5U) GC GENERAL CONTRACTOR PNL PANEL GRADE BFF BELOW FINISHED FLOOR GWB GYPSUM WALLBOARD PNT PAINT FLORIDA ACCESSIBILTY CODE FOR BUILDING CONSTR. (11BS7) BIT/BfTUM BITUMINOUS PR PAIR NOTES: -CONTRACTOR MUST COMPLY WITH COLOR SPECIFICATIONS: ALL - "PMS" = PANTONE MATCHING SYSTEM BLD BOLLARD H PSI POUNDS PER SQUARE INCH LOCAL ORDINANCES FOR PERMITTING, 3/4" SIGN BOARD -FRONT & BACK TO BE BLDG BUILDING PT POINT CONSTRUCTION AND INSTALLATION OF ALL ICI PAINT -EGRET BLK(G) BLOCKING HG HANDICAP PVC POLYVINYLCHLORIDE TEMPORARY JOBSITE SIGNAGE. PAINTED POSTS TO BE PMS 5 U BLW BELOW HDW/HDWE HARDWARE M - COORDINATE EXACT LOCATION OF SIGN 2 COLORS: BM BEAM / BENCHMARK HGT HEIGHT Q WITH ARCHITECT. A. BACKGROUND TO BE ICI PAINT -EGRET BR/BRK BRICK HM HOLLOW METAL - API LOGO AVAILABLE FOR USE IN B. LETTERS TO BE PMS 281 U BRD BOARD HORIZ HORIZONTAL QT QUARRY TILE REPRODUCTION ART OR DISK BTM BOTTOM HVAC HEATING, VENTILATING AND QTY QUANTITY (ELECTRONIC) FORM. BTW BETWEEN AIR CONDITIONING BUR BUILT-UP ROOF HW HOT WATER: R APPLICABLE CODES PROJECT IDENTIFICATION SIGN C I RAD RADIUS NORTH SHEET NO. SHEET DESCRIPTION CAB CABINET ID INSIDE DIAMETER/DIMENSION REF REFERENCE) REEL REELECTED CB CATCH BASIN/COVE BASE INCL INCLUDED) (ING) REFR REFRIGERATION CEM CI=MENT INFO INFORMATION EXISTING DOOR REINF REINFORCED) (ING) NORTH ARROW IDENTIPIC4TION COVERSHEET CER CERAMIC INSUL INSULATION READ REQUIRED PROJECT DESCRIPTION: CG CORNER GUARD INT INTERIOR RES RESILIENT INDEX SHEET CJ CONTROL JOINT CL.G CEILING G L R CLEAR INV J INVERT REV REVISION RH RIGHT HAND RHR RIGHT HAND REVERSE XX DOOR IDENTIFICATION THIS PROJECT CON515TS OF SELECTIVE DEMOLITION AND RENOVATION OF THE EXISTING STORE FACADE, FINISH ARCHITECTURAL (ARCH ITECTUREPLUS INTERNATIONAL) REY15ION NO. 1 2 3 4 5 6 GM GROWN MOULDING JAN JANITOR RO ROUGH OPENING XX FACE OF EXTERIOR WALL IMPROVEMENTS AT THE STORE INTERIOR, CMU CONCRETE MASONRY UNIT JB JUNCTION E=.30XRM ROOM pooR NUMBER AND REPLACEMENT OR RELOCATION OF D -I DEMOLITION PLAN COL COLUMN JST JOIST RTD RATED XX � SELECTED STORE FIXTURES/GASES. A-0 EXISTING CONDITIONS PLAN CONIC CONCRETE JT JOINT S A-2 CONSTRUCTION PLAN CONN CONNECT( ION) CONT CONTINUOUS SC 50LID CORE A-3 EXTERIOR ELEVATIONS, ROOF PLAN 4 DETAILS CONTR CONTRACTOR CONST CONSTRUCTION K 5CHED 5CHEDULE(D) SCJ SAW CUT JOINT WINDOW IDENTIFICATION XX XX BUILDING OCCUPANCY CLASSIFICATION: A-4 A-4.1 LUALL SECTIONS AND DETAILS WALL SECTIONS AND DETAILS CPT CARPET KIT KO KITCHEN KNOCKOUT SECT SECTION UJINVOLU LETTER FOODSTORE (MERCANTILE A-6 PARTITION TYPES 4 CONSTRUCTIONS DETAILS CR CHAIR RAIL KPL KICK PLATE SERV SERVICE COLUMN CENTERLINE OCCUPANCY -GROUP M) A-1 INTERIOR ELEVATIONS 4 TILE PATTERNS CT CERAMIC TILE SF SQUARE FOOT/FEET WALL/ PARTITION TYPE L SHT SHEET A-9 REFLECTED CEILING PLAN D LAM LAMINATED SIM SIMILAR SPEC SPECIFICATION ELEVATION TARGET xx PARTITION NUMBER SQUARE FOOTAGE: A -al A -I0 SIGNAGE PLAN DOOR SCHEDULE 4 DETAILS DEMO DEMOLITION LAV LAVATORY' SQ SQUARE EL.= 100'-0"E ELEVATION HEIGHT A-10.1 FINISH SCHEDULE 4 RESTROOM PLANS DEPT DEPARTMENT PTL DETAIL LB LBL POUND SS STAINLESS STEEL LABEL REMARK- ELEVATION DESCRIPTION TOTAL FOODSTORE SQUARE A-12 FIXTURE PLAN DP DRINKING FOUNTAIN LF STG SOUND TRANSMISSION CLASS LINEAR FOOT/FEETSTD STANDAR D REFERENCE SHEET NOTE FOOTAGE=32236 GROSS 50. FT. A-13 FLOORING PLAN DIA DIAMETER LH LEFT HAND STL STEEL MATCH LINE A-14 ENLARGED FIXTURE AND REFLECTED CEILING DIM DIMENSION LHR LEFT HAND REVERSE STOR STORAGEXX = REFE;RENCE NUMBER MATCH LINE A-16 MILLLUORK AND DETAILS D I SP D 15PENSER D15TR DISTRIBUTION LL LP LIVE LOAD 5TR STRUCTURAL/STRUCTURE LAMINATED PLASTIC MATCHLINE IpENTIFICATION CONSTRUCTION TYPE: DIV DIVISION I -TWT L ICzHTWE IGHT SUSP SUSPENDED ELECTRICAL (CHEHAI'E8 4 A380CIAtES) DN DOWN M SYM SYMMETRICAL TOILET ACCESSORY TYPE TYPE IV, UNPROTECTED, FULLY T XX SPRINKLERED ONE STORY BUILDING. E-1 LIGHTING PLAN DS DOWNSPOUT DWG DRAWING MAS MASONRY TEL TELEPHONE X SECTION CUT TOILET ACCESSORY NUMBER E-0 LIGHTING DEMOLITION PLAN DBL DOUBLE MAT MATERIAL TEMP TEMPERATURE XX E-2 ELECTRICAL PLAN E MAX MAXIMUM TJ TOOLED JOINT SECTION NUMBER � � TOTAL TOILET FIXTURE REQUIREMENT S E -2D ELECTRICAL DEMOLITION PLAN MECH MECHANICAL TOJ TOP OF JOIST SHEET NUMBER � \ (FOODSTORE): E -2K REFRIGERATION PLAN EA EACH MTL METAL TOS TO OF SLAB DETAIL SYMBOL E-3 ELECTRICAL PANEL DETAILS EJ EXPANSION JOINT MFR MANUFACTURER TYP TYPICAL -" NO ADDITIONAL SQUARE FOOTAGE 15 BEING E-4 ELECTRICAL DETAILS ELEV ELEVATION EMER EMERSENCY MIN MISG MINIMUM MISCELL,41`4EoUS J X DETAIL NUMBER DETAIL CUT XX - SHEET NUMBER ADDED TO THE EXISTING BUILDING AREA. E-5 ELECTRICAL LAYOUT FOR OFFICE 4 REGISTERS ENCL ENCLOSURE MLDG MOULDING X THE BUILDING OCCUPANCY WILL REMAIN WITH AN OCCUPANCY CLASSIFICATION OF E-5.1 CASH REGISTER DETAILS EQ EQUAL MO MASONRY OPENING U UNDERCUT UL UNDERWRITER'S LABORATORY XX DETAIL NUMBER MERCANTILE -GROUP M. NO UPGRADES TO E-1 DELI/BAKERY ELECTRICAL PLAN EQUIP EQUIPMENT MODF MTD MODIFIED MOUNT(ED) UON UNLESS OTHERWISE NOTED SHEET NUMBER THE EXISTING FIXTURE COUNTS ARE EWG ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER MTG MOUNTING UTIL UTILITY ROOM IDENTIFICATION REQUIRED. PLUMBING (ENGINEERING PROFESSIONALS, INC.) EXP EXPOSED/EXPANSION MULL MULLION V EX5T EXISTING MW MILLWORK 101 OFFICE PM FLOOR PLAN PLUMBING EXT EXTERIOR N VCT VINYL COMPOSITION TILE EXTERIOR ROOM NAME MAXIMUM TRAVEL DISTANCE TO EXITS P12 ENLARGED FLOOR PLAN VERT VERTICAL ELEVATION SYMBOL F N VEST VESTIBULE NORTH VIF VERIFY IN FIELD Roots NUMBER X MAXIMUM TRAVEL DISTANCE TO EXITS DOES MECHANICAL. (MICHAEL D. BOWERS) FA FIRE ALARM NA NOT APPLIICABLE VT VINYL TILE XX ELEVATION NUMBER NOT EXCEED 200 FT. PG FILE CABINET NIC NOT IN CONTRACT SHEET NUMBER M-1 MECHANICAL DEMOLITION PLAN FD FLOOR DRAIN NO NUMBER W REVISION MARKS M-2 MECHANICAL FLOOR PLAN FDN FOUNDATION FE FIRE EXTINGUISHER NOM NRC NOMINAL W/ WITH NOISE REDUCTION DEADEND CORRIDOR (TABLE 1104 S.B.CJ M-3 MECHANICAL SCHEDULES AND DETAILS MAXIMUM DEADEND CORRIDOR LENGTHS WC WATER CLOSET FEC FIRE EXTINGUISHER CABINET COEFFICIENT EXTERIOR FF FINISHED FLOOR NTS WD WOOD NOT TO SCALE ELEVATION SYMBOL AREA REVISED DO NOT EXCEED 20 FT. W/O WITHOUT FIN FIN15H(ED) WP WATERPROOF ER XX � REVISION NUMBER FIXTURE WWM WELDED WIRE MESH ELEVATION NUMBER - PRT PIKE RETARDANT WNCT WAINSCOT xxX 5Hl=[=7 NUMBER ABBREVIATIONS SYMBOLS PROJECT DATA SHEET INDEX -FOR ANY REFERENCES TO INTERIOR OR DECOR DRAWINGS, NOTE - ALL WORK SHALL CONFORM TO THE CURRENT EDITION OF - TRANSPORT AND HANDLE PRODUCTS IN ACCORDANCE DOCUMENT REQUIRED GENERAL THIS 15 A SEPARATE PACKAGE AND NOT PART OF THESE THE STANDARD BUILDING CODE. AND ALL OTHER WITH MANUFACTURER'S INSTRUCTIONS. CITY OF MAP REVISION No. DATE METHOD BY DESCRIPTION CONSTRUCTION DRAWINGS. GOVERNMENTAL OR REGULATORY AUTHORITIES. - PROMPTLY INSPECT SHIPMENTS TO ASSUIRE THAT - THE GENERAL CONTRACTOR SHALL HAVE MADE ALL REQUIRED - GENERAL CONTRACTOR AND ALL SUBCONTRACTORS PRODUCTS COMPLY WITH REQUIREMENTS, QUANTITIES ARE SNOT TO SGALE A N F R D ~ 1 PROVISIONS FOR THE REMOVAL OF THE DEBRIS ON SITE. c VERIFY ALL DIMENSIONS IN THE FIELp. ANY D15CREPANIE6 CORRECT, AND PRODUCTS ARE UNDAMAGED. , SHALL BE REPORTED TO THE OWNER PRIOR TO �� - GENERAL CONTRACTOR SHALL TAKE ORDINARY PRECAUTIONS TO PROCEEDING WITH THE WORK. DO NOT SCALE PLANS. - SHOULD MANUFACTURER'S INSTRUCTIONS CONFLICT WITH SECURE AND PROTECT MATERIALS. THE DRAWINGS, REQUEST CLARIFICATION FROM /2\ IT SHALL BE THE RESPONSIBILITY OF ALL ARCHITECT/ENGINEER BEFORE PROCEEDING. �� - ALL WOOD MEMBERS IN CONTACT WITH MASONRY SHALL BE SUBCONTRACTORS TO HAVE EXAMINED AND REVIEWED THE O PRESSURE TREATED. COMPLETE SET OF WORKING DRAWINGS AND/OR - CONTRACTOR SHALL PROVIDE AND INSTALL A PROJECT SPECIFICATIONS TO PROVIDE ALL LABOR AND MATERIALS SIGN, BEARING GRAPHIC INFORMATION AS W AIRPORT BLWo 5AN1=0 LAZA g - ALL METAL USED FOR CONNECTING WOOD MEMBERS GALVANIZED OR CORROSION RESISTANT. TO BE FOR THEIR RESPECTIVE AREA OF WORK, FOR THE COMPLETE AND FINISHED INSTALLATION IN COMPLIANCE WITH THE INTENT SPECIFIED/PROVIDED BY ARCHITEGTUREP'LUS INTERNATIONAL. THE SIGN IS TO BE ERECTiED BEFORE Z ��R STATS 5T P"E5NOOL o - THE "GENERAL CONDITIONS OF THE CONTRACT FOR OF THE DRAWINGS AND/OR SPECIFICATIONS WHETHER IT IS INDICATED OR NOT. START OF CONSTRUCTION IN A LOCATION AS MUTUALLY AGREED TO BETWEEN CONTRACTOR AND ARCHITECT. SEE CONSTRUCTION" AIA DOCUMENT A201, IN ADDITION TO THESE BELOW FOR SIGN DESCRIPTION. -' CONSTRUCTION DRAWINGS FORM PART OF THE CONTRACT - CONTRACTOR TO PROVIDE ALL BARRICADES, E AIRPORT BLW � DOCUMENTS. SCAFFOLDING, SIGNS, LIGHTING AND OTHER MEANS OF - ALL GRADES, LINES, LEVELS, AND SITE DIMENSIONS PROTECTION AS REQUIRED TO COMPLY WITH ALL STATE SHOWN ON THE DRAWINGS SHALL BE VERIFIED. ANY ERROR LAKE AI)A A - THE ARCHITECT SHALL NOT BE RESPONSIBLE FOR ANY LAWS AND LOCAL ORDINANCES TO SAFEGUARD PROPERTY OR INCONSISTENCY SHALL BE REPORTED TO THE DEVIATION FROM THESE DRAWINGS. AND PERSONS. OBSTRUCTIONS SHALL BE PLACED 50 AS ARCHITECT FOR INSTRUCTIONS. NOT TO DIMINISH THE LIFE SAFETY REQUIREMENTS. - SPECIFIC SECTIONS, DETAILS AND STANDARD DETAILS ARE - THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE A INDICATED ON THE DRAWINGS AT LOCATIONS WHERE THEY OCCUR, - ALL WORK SHALL BE PERFORMED BY QUALIFIED FOR PROVIDING TELEPHONE, TOILET, WATER, AND OR AT CHARACTERISTIC LOCATIONS. THEY APPLY, UNLE55 CONTRACTORS IN STRICT ACCORDANCE WITH ELECTRICITY FOR ALL PROJECT FUNCTIONS. COORDINATE OTHERWISE NOTED, TO OTHER LOCATIONS WHERE IMPLIED BY MANUFACTURERS SPECIFICATIONS AND RECOMMENDATIONS. WITH OWNER. �Q SIMILARITY OF GONSTRUGTION. - ALL MATERIAL AND EQUIPMENT SHALL 5E NEW, STORED - THE GENERAL CONTRACTOR SHALL LIMIT THE INGRESS - CONTRACTOR TO COORDINATE SPACE REQUIREMENTS AND AND INSTALLED IN A WORKMANLIKE MANNER STANDARD TO AND EGRESS OF WORKERS AND EQUIPMENT TO THE 51TE INSTALLATION OF MECHANICAL AND ELECTRICAL WORK WHICH ARE THE TRADE AND THE AMERICAN 50CIETY OF TESTING CONSTRUCTION SITE TO AUTHORIZED PER50N5 ONLY. INDICATED DIAGRAMMATICALLY ON THE DRAWINGS. FOLLOW MATERIALS. LOCATION ROUTING SHOWN FOR PIPES, DUCTS AND CONDUIT AS CL05ELY AS - THE CONTRACTOR SHALL AT ALL TIMES PROVIDE qV4 PRACTICABLE. PLACE RUNS PARALLEL WITH LINE OF BUILDING. - THE DESIGN INFORMATION INDICATED ON THE PLANS ARE PROTECTION AGAINST WEATHER TO MAINTAIN ALL WORK, VD UTILIZE SPACES EFFICIENTLY TO MAXIMIZE ACCESSIBILITY FOR INTENDED TO BE A COMPLETE AND WORKABLE SYSTEM IN MATERIALS, APPARATUS, AND FIXTURES FROM DAMAGE. AT OTHER INSTALLATION AND FOR MAINTENANCE AND REPAIRS. ACCORDANCE WITH ALL PRODUCT MANUFACTURER'S THE END OF EACH DAY ALL NEW WORK LIKELY TO BE SPECIFICATIONS, EXISTING AND/OR PROPOSED BUILDING DAMAGED SHALL BE COVERED OR OTHERWISE - IN FINISHED AREAS, UNLESS OTHERWISE NOTED, CONCEAL PIPES, DESIGN, FIELD CONDITIONS, ETC. ALL MI5CELLANEOU5 SUFFICIENTLY PROTECTED. TfPUE DUCTS, AND WIRING WITHIN THE CONSTRUCTION. COORDINATE MATERIALS, PARTS, DESIGN DIMENSIONS, WHETHER INDICATED NOFRTi4 LOCATIONS OF FIXTURES AND OUTLETS WITH FINISH ELEMENTS. ON THE PLANS OR NOT, SHALL BE INCLUDED A$ PART OF TH15 DRAWING PACKAGE. GENERAL NOTES LOCATION MAP REVISION SUMMARY ARCHIT[CTURI IU5 INTERN ATI0 NAL 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281,9299 Fax 813281,9292 E—Mail api@architecturep us.com License #AAC001935 F K ash Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- Z� ------------------------------------------------- ------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC_ #50985 GA #8343 SC #98033 ----------------------------------------------------- -- ----------------------------------------------------- To TWE BEST OF TFE MMUDCE OF TK AROiTECTS MD ENCS, SAD PIANS ar•D SFEUCATM COWRY win hE PFPUCA9F W NF" BI.IDNG GOOFS AM hE PPPMADF MMLM HE SAFETY 9FMDAFDS. KASH _ _ N' _ _KARRY NO. _ 1890 SANFORD,--- L------------------------- PROJECT NAME INDEX --- SHEET -------------------------------------------------- SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: DR CHECKED BY: API SCALE AS NOTED ISSUE DATE 9/06/01 ----------------------------------------------------- ISSUE FOR: BID/PERMIT ------------ --------- -------------------------------- SHEET NUMBER ARCHITICTURI [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813,281.9292 E—Mail api@architecturep us,com License #AAC001935 PrA Kash n Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. A ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935NC #50985 -- -- GA ----------------------------------------------------- ---------- ---- #8343 -SC #98033 ----- ------------------------------------- ------- To TFE BEST OF TFE W O&EDGE CF RE AFGHTEGTS AND EFUPEEM, 340 Rj" PND aEGFY_ATXW GDNfl-Y VrH THE PFR1C?ELE NW4" BULDNG OWES PTD TFE AFF"BLE MNMUM FiE SAFETY STAPDAFEr. KASH --N' --KARRY------N-0. 1890 ------------------------------------------ SANFORD,-- FL------------------------- PROJECT NAME DEMOLITION PLAN DEMO -LIT -ION --- ----------------------------------------------------- SHEET NAME PROJECT NUMBER: 9949.01 ----------------------------------------------------- DRAWN BY: DR CHECKED- BY: API ---------------------------------------------------- SCALE:AS NOTED ----------------------------------------------------- ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE FoFt BID/PERMIT ----------------------------------------------------- ------------------- D-_1 -------------------- SHEET NUMBER I PUMFFT R PAP r -------t r------- I I I I v 14 l I I I I I I I I ------------ EXIT EXIT II POTATO II 40' HZVS1 PRODUCE PRODUCE PREP. ROOM ii 80' LV5N1 FROZEN FOODARCHIT[CTUR[ v a N N II w I N T E R N A T I O N A L Ll 6(d' LVSHI FROZEN FOOD Q Q7V U� -1 X00 4 W 4 1 1 II j0 ee I ��� e� o ° – �.4 2709 Rock Point Drive Suite 201 Lu I" a II �N y II Tampa, Florida 33607 O N i i O' LV5H1 FROZ N FOOD `n U w Tel 813281,9299 I u UX �t U ii 62' GONDOLA OQ 4i – – – —;—;- 5 Fax 813281,9292 CONCRETE w II ti q E—Mail a I@architecture us.com I I TRUCK PAD IL�° p p License #AAC001935 Z � ii 64' CzONDOLA �e I I 2111 I I I (L/ 5AG3-120 5AG3-110 lull �Lu Q 0 11 2111 p/ MEAT COOLER p ii (Jul I I (k 34 -1 xl4 II 1 I � I I 114' GONDOLA (5 ROWS) • 9AGGI-41-41 i i 18' ENTRY • - - - • I' I • ® TRAY COOLER I ii I I I 4.3 f 4'-4"x10 -1" • ii 2111� EXIT II N ---/I 0 i ----- ® B ii 11 . I CARTS IIly- ----MEAT PREP. ROOM i i w MEAT FREEZE ,I ---- ;; 24" 0 VESTIBULE I I _ • _ _ _ _ _ _ _ _ _ _ _ _ _ _ -� _ _ _ 3., n I 'rNITOI U ii Q e 3.6 MEAT RECEIVING ROOM[x] TORR �� I I I 4 0 I I arr I L u- ® Ki y P lq 2111tu Il I I I�I 1 I N ® ® ® ii uU� EXIT GROCERY ;0 �' ROOM A Z 24" STORAGE [K © AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. I II U I I ENTRY ^• TB 111 II - F I U ii 66' GONDOLA l3 ROWS) m�� � i I ----------------------------- � LOUNGE 4 I ii 51-A ii Xn i i X0 1 iL O q U i [L ----------------------------------------------------- ® OFFICE OFFICE ACEsE i i 2.5 qU Z �cn — R Q — — 0 iu� - ---------- ------ --- -- --- -- ---- --------- �� __ ____ — 2A REVISION LOG I I I I iin4 2111 I I lit DELI/ .0 w I I II µ BAKER fl ® ii}� ��1� �1_ " I I p� 4 pAIRY COOLER II _ STATE REGISTRATIONS }-� ----------------------------------------------------- 3 x20'3" ;; _)rT ; ; (L U z " -'�� aFL #AA001935 NC -- 0985 - ------------------------------------------------ GA 343 SC 98033 — — — — — — — — ui CONCRETE I TERVIEWING ROO C}' 'I . i i Q --------- --- ----- - - --- ------ ---- ----- - - TRUCK PAD I I 110 I 1 I Q w II � ii I I � I i,U ®❑ i DELI/BAKERY MEN WOMEN �� ii 26' GONDOLA 40 D61 BI=ERR STORAGE ROO ;; 2-111 ; ; — 1•i EC i- ' 2111 I 116' - i i DO I I xAGS-Ism ``� ii i LI/BAKERY AREA (L II 5'-6" LDIGI 5' 6" LDIC1 II� " F9 1 ii DAIRY PROMO DAI Ply PROMO ICE CREAM FZR 'I 40' IV5HI ICE CREAM O I1:3 r'__ iir ' WQ I I } I 1 I ----------------------------------------------------- > TO TFE BEST OF TFE IQJ & DGE CF THE AW>MTS ASD 9" EEMN BPD KANE; APD SPRINKLER RISER ii iiV� ELI/BAKERY I i SCALE , DLU AMICABLE��Y �Y MW1 �u+BUFnMG cols ArD TFe L5 AI ,,� Q FREEZER 11 I MEZZANINE PLAN2WANDAFM ORRIDOR No.2 DRIN ��12' D61 EGGS 84' D61 DAIR FROZEN DELI 1:;) � g -S x11 -( ----- I I 3/32`=1'-0" SECURITY RM. I 8PL _ 1 EXI ND I '1 I I I ii sari Izm 1. THE EXISTING CONDITIONS PLAN ON THIS SHEET IS INTENDED TO 1.1 CONVEY THE APPROXIMATE CONDITIONS OF THE BUILDING. ALL DATA KASH N' KARRY NO. 1890 ` DELI/BAKERY SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO THE SUBMISSION 1 -I J I CLOSET 1 OF BIDS AND/OR THE COMMENCEMENT OF WORK. ANY CONDITIONS SANFORA FL I I I I I WHICH DIFFER SUBSTANTIALLY FROM THAT INDICATED ON THE EXISTING ---------- ----------------------------------- CONDITIONS PLAN OR THE CONSTRUCTION DOCUMENTS, SHALL BE PROJECT NAME • • • IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT. l . EXISTING CONDITIONS FA B•1 B A.1 A THE MEZZANINE LAN IS NOT SHOWN ON THE ARCHITECTURAL SHEETS NSINCE THERE IS TO BE NO WORK OTHER THAN THAT WHICH IS CALLED PLAN FOR IN THE MECHANICAL, ELECTRICAL, OR PLUMBING PORTION OF THIS ----------------------------------------------------- TRUE CONTRACT. SHEET NAME NORTH 3. GENERAL CONTRACTOR SHALL PHOTOGRAPH OR VIDEOTAPE EXISTING PROJECT NUMBER: 9949.01 CONDITIONS IN AND AROUND THE STORE PRIOR TO BEGINNING -"------------ ------- ------ --- --- --- --- --"--- j CONSTRUCTION. PARTICULAR ATTENTION SHOULD BE DIRECTED TO THIS DRAWN BY: DR CHECKED BY: API ROOF AND ALL ASPHALT DRIVES AND PARKING AREAS. ----------------------------------------------------- PLAN SCALE: NORTH 4. THE GENERAL CONTRACTOR SHALL REVIEW THE HAZARDOUS MATERIAL - --------AS S -----NOTED TED---------------------------- REPORT AND COORDINATE ALL HAZARDOUS MATERIAL REMOVAL WITH 9/06/01 THE KASH N' KARRY ISSUE CONSTRUCTION SUPERVISOR. ISSUE ATE:__________________________ ISSUE FOR: BID/PERMIT ----------------------------------------------------A�O a ----------------------------------------------------- EXISTING CONDITIONS SCALE 1 GENERAL NOTES SHEET NUMBER 3/32"=1'-0" I i II , • Al 25 106 RECEIVING 25 110 GROCERY ST 1148 TRAINING 116 WOMEN'S ROc 115 MEN'S ROOM 114A INTERYIEWINC r ��M IIS DELIBAKERY 5 114 SECURITY 6'-5" 16 Ii PI I211 102 PROpUCE PREP. 102A� �.��w„ COOLER 1. McGUE CART STOP 6LIMLINE 0`1 -_62ND -40. COLOR: 0-149 "LAVENDER" FLOOR MOUNT. 2. EXISTING GONG. WALK TO REMAIN. PRESSURE WASH SURFACE. PATCH TO MATCH EXISTING CONDITION. 3. PROVIDE NEW WINDOW AND LINTEL. PATCH TO MATCH AS REQUIRED. REFER TO CONSTRUCTION PLAN SHEET 3/A-6. 4. PROVIDE NEW CONC. BOLLARDS. REFER TO CONSTRUCTION DETAIL SHEET. 5. EXISTING FRAME TO BE SANDED, FILLED, PAINTED FOR REUSE IN PRESENT LOCATION. REFER TO INTERIOR ELEVATION SHEET FOR COLORS. 6 6. NEW TOILET PARTITIONS. REFER TO RESTROOM PLANS SHEET A-10.1. ------------ 5,9 I. NEW CERAMIC TILE FLOOR. REFER TO FLOORING PLAN SHEET A-13. 1 16 it ; S. VERIFY CONDITION OF EXISTING CAN WASH AND REPAIR AS REQUIRED. COORDINATE SCOPE OF WORK WITH KASH N' KARRY CONSTRUCTION O ii I i REPRESENTATIVE AT PRE BID WALK TNRU. 9. NEW E.W.C. AND 2 DIAMETER PIPE GUARDS. I I H 10. REUSE EXISTING 1/2" GWB ON EXISTING SUBSTRATE TO RECEIVE NEW CERAMIC TILE FINISH. REFER TO INTERIOR ELEVATION SHEET A-7. I I I it I I 1 x 20 I - �.4 11. NEW MARLITE TO BE APPLIED TO EXISTING WALL FINISH. 12. EXISTING CART CORRAL TO BE REPAINTED. REFER TO SHEET A-3 FOR I ADDITIONAL DETAIL. 4 13. EXISTING HEAD ABOVE TO BE PATCHED TO MATCH EXISTING -4. CONDITIONS AFTER REMOVAL OF STOREFRONT SYSTEM. 'I 20 i i OPP. HAND EXTERIOR 14. EXISTING SPLIT FACE BLOCK WORK TO BE PAINTED SEE ELEVATION SHEET A-3, REFERENCE NOTE *10. 11 e 15. HATCHED AREA INDICATES APPROXIMATE AREA TO BE REPAIRED TO 16 l - �� MATCH EX16TING FLOOR AFTER REMOVAL OF LOW WALL AND WINDOWS. it 4,4t,- MEAT/SEAFOOD COOLER I I 1048 it I LI It 104E TRAY COOLER II , II , ii it • 2 � ii I I 4 16. EXISTING COLUMNS IN GENERAL SALES AREA TO BE REPAINTED. 1q i i w TYP. REFER TO INTERIOR COLOR SELECTIONS ON INTERIOR ELEVATION I > SHEET. li. PROVIDE NEW 3 COMP. SINK 28 I I I 3 I8. LINE INDICATES THE LIMITS OF THE NEW "AXIOM" PERIMETER TRIM (o (-Ir i-- '41 ABOVE. REFER TO ENLARGED PLANS ON SHEET A-14. 6 Ii _0 42 OPP. HAND_ry19. PROVIDE NEW ALUMINUM SILL COVER PER SILL DETAIL 7 ON SHEET A-6. 104A MEAT/SEAFOOp PREP. II ' 15 I I}= 19 20.FILL ABANDONED REFRIGERATION PITS W/GONG. FLUSH WITH EXISTING X15 22 +' 29 I i } FINISHED FLOOR. DOWEL INTO EXISTING SLAB. it , I I I SINK. 21. RELOCATED EX15TING 2 COMP. 3 it ' 104 MEAT/SEAFOOD 5ALE5 - I i 1 21 Q-6 I I 39 22. PROVIDE DUCT FOR SENSORMATIC INSTALLATION. REFER TO 104-_ MEAT/5EAFOOD FREEZER A'6 ii ' 3 A8Y• , I I I 2 1 I I �-' ' ' ELECTRICAL DWGS. FOR EXACT LOCATION OF WORK. -10A-3 23. NEW PLEXIGLASS WINDOW ON TOP OF EXISTING WALL. REFER TO DETAIL ii { I 1 100 VESTIBULE I I I I _ 3.1 S/A-6. 24. PROVIDE NEW 1 COMP. SINK 8 i�-J I 101 GENERAL SALES I I L i i u u I I � � � 1 , , 25. NEW LOADING DOCK BUMPERS, DOCK SEALS AND LEVELERS. JANITOR I ii '�'-� 1 �..a_ j , I 3.4 COORDINATE WITH KN'K CONSTRUCTION REP. 1[ 107 II `� I i p 0 POCK LEVELERS: ii O 20 1D 22 1 T i i r gn SUPPLIED BY: CAROLINA INDUSTRIAL SYSTEM, INC. CONTACT: DAVE � -- � MEAT STORAGE j II 18 A-1 IA I I i:1_ 2 6 i 3 WHITING-�TON (33ro) 852-5663. a 104D I I 15 +- 2 3 11 1 IC -4. DOCK DEALS: IIT:;= 2-I SUPPLIED BY: CAROLINA INDUSTRIAL SYSTEM, INC. CONTACT= DAVE ii 10 I ( �� r'.1 WHITINGTON (336)852-5663. ii OPP. HAND A_6 CAROLINA INDUSTRIAL WILL ALSO INSTALL BOTH LEVELERS 4 SEALS, A TIME FOR GENERAL CONTRACTOR NEEDS TO GALL AND SET UP ROOMii - 118 CUSTOMER INSTALLATION. INDICATES EW 3 5/8" h'IETAL ---- «l SERVICE 26 REPAIR FLOOR AND WALLS, IF REQUIRED, AFTER WOOD AND/OR ii - ? CONCRETE CURB IS REMOVED. II STUD WALL. - 1 I 14 EISA C>FFICE INDICATES ELXISTINCc WALLS.II I 21. INSTALL CART BUMPER SYSTEM ON VESTIBULE WALL. (SEE NOTE 6 ON OFFICE STORAGE SHEET A --i). ii INDICATES ONCRETE FLOOR IS 10 - -t1- ROOM ii II SLAB TOB REPAIRED. 28.INSTALL SPRINKLERS IN FRONT CANOPY. REFER TO REFLECTED CEILING I / I I 2S PLAN 1/A-9. I II I SEE PARTITION/UJALL TYf�E DETAILS ON UP SHEET A-6. ; J 23 - 12 - - �� II - _ - - - _ _ _ �r-------- 29. FLOOR MOUNTED McCUE CARTSTOP, COORDINATE WITH SHEET A --f 20 / - 28 ' 2.4 (TYP). II / II 4. REFERENCE NOTES O DELI/BAKERY 111 II 16 /� ;;/'� i i 1178 COOLER I SERVICES TO EXISTING TEN DR SHALL MAINTAIN ALL UTILITIESAND AIRY COOLER ANT SPACES (VACANT OR OCCUPIED) 2 DURING DEMOLITION AND CONSTRUCTION. UTILITIES AND SERVICES SHALL INCLUDE BUT NOT BE LIMITED TO: ELECTRICAL, PLUMBING, GAS, DELIBAKE SAL �S i i WATER, FIRE SPRINKLER, FIRE ALARM SYSTEMS, ETC. ANY SCHEDULED I A-101 117 �� I INTERRUPTION OF SERVICES REQUIRED DURING DEMOLITION OR CONSTRUCTION SHALL BE COORDINATED WITH KASH N' KARRY AND OR I ii I I i ii iIi TENANTS AT LEAST SEVEN (l) DAYS PRIOR TO INTERRUPTION. 6 6 I ii i ii 24 2. ALL ABANDONED PLUMBING AND REFRIGERATION LINES SHALL BE © IDELIBAKERY CAPPED BELOW FINISHED SLAB LEVEL. FLOORS SHALL BE PATCHED I ii I ii I IIIA PREP. TO MATCH EXISTING ADJACENT CONDITION OR PREPARED TO ACCEPT NEW FINISH. NTER LINE OF 3. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR Cr ii 20 ii i i COLUMN. UNLESS OTHERWISE NOTED. I 6 I ii I I ii it I 2 4. REFER TO PARTITION TYPES ON SHEET A-6 FOR PARTITION ii 5 8 CONSTRUCTION DETAILS. 9 8 ii ii 5. THE G.C_ SHALL BE RESPONSIBLE FOR MAINTAINING ALL EXISTING LIFE ii I 1 ii ' ' SAFETY SYSTEMS AND EQUIPMENT INCLUDING BUT NOT LIMITED TO FIRE ii 11 I II - 1.1 I � ALARM SYSTEMS, AUTOMATIC FIRE SPRINKLERS, EMERGENCY LIGHTING, EXIT LIGHTING AND FIRE EXTINGUISHERS FOR THE DURATION OF CONSTRUCTION. THE G.G. SHALL COORDINATE THE LOCATION OF NEW PELIA3 KERY CL05ET I I Y'«" 1 I 117D OR RELOCATED FIRE EXTINGUISHERS WITH THE BUILDING OFFICIAL 105A CORRIDOR 02 1 HAYING JURISD IGTION. DELI/BAKERY • • • I FREEZER 6 . THE GENERAL CONTRACTOR SHALL PROTECT ALL EXISTING FIXTURES, O 117-_ B A.1 A FINISHES 4 STRUCTURE ETC. TO REMAIN. FAO O O G 4N -i. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH DRAWINGS AND SPECIFICATIONS OF ALL APPLICABLE TRADES AND ENGINEERING DISCIPLINES. TRUE NORTW 8. FILL ABANDONED REFRIGERATION PITS W/GONG. FLUSH WITH EXISTING FINISHED FLOOR DOWEL INTO EXISTING SLAB. 9. GENERAL CONTRACTOR SHALL INSPECT TRUCKWELL WALLS, 6LA5AND GUARD RAIL WITH THE KN'K CONSTRUCTION REP. AND DETERMINE ON SITE WORK TO BE DONE IN THE AREA. INCLUDED IN THIS WORK IS PLAN VERIFYING THE EXISTING TRUCKWELL SUMP PUMP IS IN A GOOD NORTH WORKING ORDER 4 CAPABLE OF PERFORMING IN THE CORRECT MANNER 10. GENERAL CONTRACTOR SHALL INSPECT EXISTING HANDRAILING 4 GUARD POSTS TO BE INSPECTED FOR REFURBISHING. COORDINATE W/KN'K CONSTRUCTION REP. R PLAN SCALE 1 GENERAL NOTES CONSTRUCTION FLOG 3/32"=V-0" ARCHIT[CTURI IUS I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813.281.9292 E -Mail api@architectureplus.com License #AAC001935 FA' Kash n'� ir4(Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Z� ------------------------------------------------- A------------------------------------------------- 0------------ ------------------------------------- -------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935NC-#50985 ----- ---------------------------------- GA #8343 --------SC #98033 ----------------------------------------------------- ----------------------------------------------------- TO TFE BEST OF TI -E MOMEDGE OF TFE AACFREMS AND EA[3Effi9, W RAW AND SPECFICATaS CONKY WITH THE APPLICABLE MNMJM BLA-DW CODES AND TFE AFRICABLE MNMUM FIFE SAFETY STANOAFM KASH N' KARRY N0. 1890 SANFORD,-- FL ------------------------- PROJECT NAME CONSTRUCTION__ PLAN_____-_ ----------------- SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: DR CHECKED- BY: API ---------------------------------------------------- SCALE: AS NOTED ISSUE- - - DATE: 9/0-6/01 ------------------------------------------------- ISSUE-FoFt-BID/PERMIT --------------------------------------------------- Ar__2 ------------------ SHEET NUMBER ARCHITfCTUREP[US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281,9299 Fax 813.281,9292 E -Mail apl@architectureplus.com License #AAC001935 Fr(Ki shn A ,I Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC #50985 ----------------------------------------------------- GA #8343 SC #98033 ----------------------------------------------------- ----------------------------------------------------- i� ---------------------------- ------------------------- TO THE BES" OF TFE TQ HEDGE OF THE AWA ECTS AND ffr.N EF6, SAD FtMS AND SFEGMATOS OOWLY V4N TFE APR -CABLE MWAN BJUING CODES AND TFE AFPLCA 3LE hTltvAM FOE SAFETY STANDAFM FOOD--- ION__NO.__1890-_______ SANFORD,__ FL____---_____ ------------ PROJECT NAME EXTERIOR-- ELEVATION, ROOF PLAN & DETAILS SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: PH CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ISSUE FOR: BID/PERMIT ----------------- ------------ ------------------------ SHEET NUMBER POLYURETHANE CAULK 1. EXISTING CANOPY'S STANDING SEAM ROOF TO REMAIN. COLOR FILL FLANGE CORNERS MECHANICAL CLAMP NEW EFIS. REFER TO WALL SECTIONS. PER ELEVATION. W/BEVELLED EDGES 24 GA STAINLESS 2. EXISTING COPING TO REMAIN, COLOR AS PER ELEVATION. STEEL WEATHER CAP 3. COLUMN BOX OUT OR WALL BELOW. REINFORCED EGDE I 2" POURABLE SEALANT 4. EXISTING PARAPET TO BE MODIFIED TO ACCOMMODATE NEW 1 I I I 24 GA STAINLESS PARAPET. STEEL PITCH PAN PROVIDE CONT. SEALANT 5. EXISTING ROOF TO REMAIN. ASPHALT FILL 6. NEW METAL COPING. COLOR AS PER ELEVATION. ELASTOMERfG FLASHING TWO PIECE COUNTERFLASHING -i. NEW CORNICE/PARAPET . MIN. OF S" ABOVE FINISHED xxxxxxxx x xxxxxx ROOF OR PARAPET DETAIL 8. PROVIDE 5/8" FRT CDX PLYWD. IN LIEU OF GWB SHEATHING FOR LEVEL IIRED. COORDINATE W/SIGNAGE MANUFACTUREPPOR R.CSIRCEa NEW COUNTERFLASHING TO PROVIDE POSITIVE COVERAGE. 9. NEW CEMENT PLASTER FINISH. SHIM AS REQUIRED TO ASSURE ALIGNMENT W/FINISH ABOVE. REFER TO COLUMN DETAILS AND EXISTING STANDING SEAM ROOF TO SECTIONS. BE MODIFIED TO ACCEPT NEW CONSTRUCTION. 10. EXISTING SPLIT FACE BLOCK FINISH TO BE PREPARED FOR NEW SET FLANGE IN FULL BED PAINT. OF MASTIC EXISTING SUBSTRATE. 11. NEW CONTROL JOINT. NOTE: THIS DETAIL BE CONSIDERED 12. NEW CONCRETE CURB, REFER TO CONSTRUCTION DETAIL SHEET SHALL TYPICAL FOR TUBULAR PENETRATIONS A-6. NO PAINT. NOT USED SCALE $ PITCH POCKET DETAIL SCALE 7 BASE FLASHING SCALE 6_ 13. NEW PAINTED STEEL PIPE BOLLARD. REFER TO CONSTRUCTION DETAIL SHEET A-6. (COLOR "E") N/A 14. NEW LIGHT FIXTURE. BOTTOM OF FIXTURE TO ALIGN W/ TOP OF NEW CEMENT PLASTER REVEAL AT EACH NEW COLUMN BOX OUT (ADJACENT TO BOTTOM OF NEW SOFFIT). REFER TO SECTIONS. C T 15. NEW EIFS ON 1 1/2 EP5. ROOFING MEMBRANE ON � FL = 30'-0„ AFF 3/4" PLYWOOD. 16. EXISTING SOFFIT TO BE PAINTED. 5/8 FRT CDX PL'1'WD. T.O. PARAPET 11. EXISTING STOREFRONT GLAZING TO REMAIN. (HIGHEST POINT) - SINGLE PLY MEMBRANE 18. PROVIDE 3/4" x 3/4" REVEAL IN NEW CEMENT PLASTER FINISH. TO EXTEND UP AND CONTINUOUS BEAD OF SEALANT EL = 2"I'-0" AFF OVER PARAPET 19. PROVIDE 3/4" X 3/4" REVEAL 10 TRANSITION FROM CEMENT TOOLED TO FASGILITATE WATER T.O. PARAPET (LOWEST POINT) PLASTER TO EIFS. REFER TO DETAIL A-3. RUN OFF. CLEAN ALL METAL RADIUS=82'-5 15/16" SURFACES TO BE SEALED TO 20. EXISTING CART CORRAL TO BE REPAINTED. (COLOR "A") ENSURE PROPER ADHESION. ENSURE SEALANT IS COMPATIBLE LINE OF CMU OR STUD 21. NEW PAINT LINE. WITH ALL MATERIALS USED. WORK, EXT. GRADE FRT. CDX PLYWOOD. 22. NEW LIMITS OF ROOF DECK EXTENSION OVER NEW COLUMN BOX OUTS BELOW. PEAL AND STICK MEMBRANECONTINUOUS TO EXTEND 12" MIIN. ABOVE METAL RETAINER PAR. (IF rSECTIONS 23. EXISTING SPLIT FACE CMU BOX OUT TO REMAIN. AND BELOW THE 6" L -ANGLE. NEEDED) TWO TWO PI PIECE 24. NEW PARAPET ANGLE AND BRACE TYPICAL OF (4). REFER to COU RFLASHING AND DETAILS. ALIGN WITH EXISTING JOISTS. SYSTEM EQUIVALENT TO FRY 5PRINGLOK 25. NEW FLASHING. REFER TO DETAIL 6/A-3. REGLET, TYPE 5TX". 26. SITE FRAMED PARAPET SADDLE. REFER TO DETAIL 5/A-4. 01 22'-31/2" PARAPET BRACE FLASHING SCA2LE, DETAIL @ MAIN PARAPET SCALE 4. BASE FLASHING SCALE 3 1 0 /43`=11'-O" 4 7 -I A-3 TYP TYP. 3 4 5 TYP. 6 A-4 A-4 A-lra 2� 24 5 TYP. 2 2 B � ,4.1 A I EM 1 TYP: 22 22 1 1.1 1.1 2.4 3.1 3.1 4.2 4.8 ROOF PLAN SCALE 2 REFERENCE NOTES O y1 = 3/3 '�► QA 4 -f 4 A2.1 � 1 1.1 1.1 2.4 3.1 C 3.7 4 4.8 5.4 8.9 6 6 � X PAINT COLORS: O 26 26 I 'I APP. COLOR A = DEVOE 4WI�o -2 GAZELLE TYP. TYP- TYP. TYP- T.O.= ARA T.PAR PET/CORNICE CHEW) F 2 C C EL - 2,' -ID" A�P.F. T.O. UPPER CC7RNICE COLOR 1=3 = DEVOE 4W12-3 COf PEfRDUST TIP 15 F 2 (NEW) II II TT COLOR C = DEVOE 31.U23-1 MOUNTAIN TOP EL = 22'-8" AQP. COLOR D = STANDINC- SEAM CANOIP�' 4 METAL 21 C 15 S C41 W%h, TA aa& k \�r�=-2" APP. 21 G EXISTING PARAPET COPING. CUSTOM <YNAR FINISH TO MATCH PMS#3125U TYP- 21 25 COLOR E = O A B LL RDS ' F F I PAINT TRAFFIC YELLOW TYP. I5 C 16 �, EL =V-0` AFP. COLOR F = DETAILS 1m lm 14 19 10 17 �� i i i I -I 10 S.O. EXIST. SQFFIT 14 TYP. 1m 1m PAINT TO MATCH PMS#3125U. 21 C TYP '�'P. , 9 1-I 1-I , 18 G 21 G COLOR 63 = DETAILS �FTYf=>�, lm r EL = 3'-4" AFP. T.O. NEWPAINT LINE PAINT TO MATCH BENJAMIN MOORE #1021 . FINI5H FLOOR 23 13 12 2m 23 I I 2 2 TYP. YP. TYP. TYP. A-4 A-4 A-4.1 A-4.1 FRONT ELEVATION SCALE 1 EXTERIOR COLOR SELECTION 3/32 -10 ARCHITfCTUREP[US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281,9299 Fax 813.281,9292 E -Mail apl@architectureplus.com License #AAC001935 Fr(Ki shn A ,I Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC #50985 ----------------------------------------------------- GA #8343 SC #98033 ----------------------------------------------------- ----------------------------------------------------- i� ---------------------------- ------------------------- TO THE BES" OF TFE TQ HEDGE OF THE AWA ECTS AND ffr.N EF6, SAD FtMS AND SFEGMATOS OOWLY V4N TFE APR -CABLE MWAN BJUING CODES AND TFE AFPLCA 3LE hTltvAM FOE SAFETY STANDAFM FOOD--- ION__NO.__1890-_______ SANFORD,__ FL____---_____ ------------ PROJECT NAME EXTERIOR-- ELEVATION, ROOF PLAN & DETAILS SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: PH CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ISSUE FOR: BID/PERMIT ----------------- ------------ ------------------------ SHEET NUMBER ARCHIT[CTURI [us I N T E R N A TI O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281,9299 Fax 813.281.9292 E—Mail api@architectureplus.com License #AAC001935 or(Kash n Pv'A Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- Z� REINFORCED ROOFING ----------------------------------------------------- ROOFING MEMBRANE ------------------------------------------------- ------------------------------------------------- REINFORCED ROOFING ROOFING MEMBRANE STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC #50985 ------ GA ----------------------------------------------------- ----------------------------------------------------- EDGE At EDGE ON 5/5" FRT GDX ----- ----------------------------------------------- TO THE BEST OF THE IQJ &EDGE OF THE AC"TECTS aro Eta SAD PLAM APD SPHFCATUI S CLtuFLY WITH THE APPUCABLE MNMUM BULDNC' CODES AND THE APPUCABLE MNt" FIFE SAFETY STAroAfiB. AT EDGE ON 5/5" FRt CDX EIFS ON 1-1/2" EPS ON CONTINUOUS P. T. PLYWD. PLYWD. 5/5" M.R GYPSUM SHEATHING ON MTL. STUDS. PROVIDE A WOOD CUT 2X8 1._3„ OVERLAP ROOF MEMBRANE ONTO STOP CONTINUOUS P. T. WOOD CUT 2X8 I -3 OVERLAP ROOF MEMBRANE ONTO PVC J MOULD AT GRAVEL FLASHING. GRAVEL STOP BOTTOM EDGE OF - FLASHING. GYPSUM SHEATHING `V CONT. 2"X4" P.T. WOOD `�' SITE FRAMED !n BLOCKING CONT. 2 "X4" P.T. �n WOOD BLOCKING PARAPET SADDLE,X.- DRAINED TOWARDS • • CONT. HOLD DOWN CLIP • ROOF STRUCTURE. • • t: CONT. HOLD DOWN PROVIDE ROOFING CLIP MEMBRANE ON 5/8" • ',' FRT CDX PLYWOOD. - CONTINUOUS ` ° CONTINUOUS 2x2x20GA. MTL. 2x P.T. WOOD `r ANGLE - 2x2x2GGA. MTL. ANGLE BLOCKING EIFS W/1 1/2" EPS ON CONTINUOUS 5/8 GLASS MATT - EIFS W/1 1/2" EPS ON 5/8" GLASS MATT 2x2x2OGA. MTL. SHEATHING ON METAL SHEATHING ON ANGLE STUDS METAL STUDS 3 1 -011 CONTINUOUS RAIN DRIP CONTINUOUS RAIN DRIP 31111-011 ROOFING MEMBRANE ROOFING MEMBRANE CONTINUOUS RAIN ON 5/5" FRT CDX ON 5/5" FRT CDX PLYWD. LAP OVER DRIP PLYWD. LAP OVER NEW NEW NEW METAL STUD COUNTERFLASHING GOUNTERFLASHING NEW METAL STUDS. EIFS ON 1-1/2" EPS ON NEW MTL. SCUDS 5/5" GLASS MATT ATTACHED TO SHEATHING SHEATHING v EXISTING CMU. REFER ON MTL. STUDS. TO SECTIONS. CORNICE DETAIL SCALE 5 CORNICE DETAIL SCALE 4 CORNICE DETAIL SCALE 11/2"=1'-0" „,2"=1'_0.. ,i, EL = 30'-0" AFF T.O. NEW PARAPET BEYOND (HIGHEST POINT) I OILEL = 21'-0" A.F.F. T.O. NEW PARAPET BEYOND I I (LOWEST POINT) E3 3 I _ A-� T.O. NEW CORNICE NEW 5" 20 GA. METAL STUDS Q 16" PROVIDE MTL. FLASHING I O.C. MTL. STUD W/L4x4x14GAx4" I I EL = 22'-2" A.F.F. REFER TO 3/A -3I D LONG CLIP ANGLE (2) EA. TOP T.O. EXISTING PARAPET BTM. AND (1)4'-0" O.C. MAX. BETWEEN. FASTEN TO CMU WK2) EXISTING ROOF EXISTING ROOF N, l 0.14 MIN. DIA. E 11/4" MIN LENGTH POWDER DRIVEN FASTNEIRS. — J I FASTEN STUDS TO CLIP ANGLE W/(3) 1*12 TEK SCREWS. EL = 15'-5" AFF EL = 15'-5" AFF B.O. EXISTING JOIST BRG. NEW EIFS ON 1 1/2" EPS ON 5/ M GLASS MATT SHEATHING ON MTL B.O. EXISTING J015T BRG. STUDS. NEW CONTINUOUS FLASHING. REFER TO EXISTING HORIZONTAL I 6/A-3 EXISTING HORIZONTAL EXISTING RAISED SIDE JOINT REINF. AT EXISTING RAISED SIDE JOINT REINF. AT PARAPET BEYOND ALTERNATE COURSES PARAPET BEYOND ALTERNATE COURSES EXISTING STANDING SEAM EXISTING STANDING SEAM ROOF ROOF TO BE REPLACED EXISTING 2x WOOD EL = 12'-0" AFF NEW PREFINISHED DRIP EDGE EL = 12'-0" AFF STUDS EXIST ACT GLC.EXISTING ROOF TRUSS I EXIST ACT CLC. EXISTING ROOF TRUSS I FS FINISH ON 1-1/2" EPS ON EL = 10'-6" AFF - GLASS MATT SHEATHING ON 5/S" EL = 10'-6" AFF - _ EL = 10'-6'12" A.F.F. EXISTING CANOPY 3-5/5" MTL STUDS ON EXISTING EXIST. CANOPY CEILING T.O. STEEL BEAM CEILING TO REMAIN. - N FRAMING. tL PATCH AND REPAIR TOEL ACCOMMODATE NEW / EXISTING BEAM = V-1'/, *- " AFF. // EXISTING LINEAR AIR � EL = 9'-0" AFF HT. OF TRANSITION (lC VENT B.O. EXISTING SOFFIT RUGTION AND (REVEAL), NEW LIGHT Wd) EXIST. 1/2" GWB I PAINT. FIXTURE f� EXISTING STEEL COLUMN w U EXISTING ALUM. FRAME AND MASONRY COLUMN EXISTING ALUM. FRAME— TO REMAIN. EXIST. 1/2" GWB 3/4" CEMENT PLASTER ON PAPER BACKED WIRE ATH � � � � _ � EXISTING STEEL COLUMN (TYP) OVER 5/5" M.R. GYP. SHEATHING ON MTL. STUDS (L/ C� N�R�,L,. ��L�v SPLIT FACE CMU COLUMN. COL EL = 3'-5 1/2" A.F.F. EXISTING ALUM. EXISTING SPLIT FACE NEW 3/4" x 3/4" GEMENT x EXISTING SPLIT FACE ENTRANCE DOORS TO CMU PLASTER REVEAL p CMU REMAIN NEW 5%. BOLLARD, REFER TO CONSTRUCTION DETAIL Uy Q SHEET A-6-� } EXISTING GONG. SLAB 7000000 0000000000Cc( FINISH FLOOR EXISTING GONG. SLAB 7000000 0000000000OCr FINISH FLOOR EXISTING COMPACTED FILL goo 0000no n I EXISTING ASPHALT EXISTING COMPACTED FILL ,goo 0000n -0 I FLUSHI WITH EDGE OF NEW CONCRETE CURB FLUSH WITH EDGE OF EXISTING GONG. FOOTING I (SEE DETAIL ON SHEET # GONG. WALK (TYP) EXISTING CON(. FOOTING CONG. WALK ITYPJ A-6). NOTE: AUTOMA IC p00RS ARE NOT SCHEDULED FOR REPLACEMENT. IF DECISION IS MADE IN THE FIELD THE GENERAL CONTRACTOR SHALL CONTACT UNITED DOOR SERVIGE AT 1-517-531-366-( IF AUTOMATIC, DOOR PACKAGES NEED TO BE REPLACED. ALSO COORDINATE WITH THE KN'K CONSTRUCTION REP. AND INSURE THAT THE WORK IS COMPLETED PRIOR t0 THE BOXING OUT OF THE CANOPY COLUMNS. WALL SECTION @ CANOPY ENTRANCE (NEW) SCALE 2 WALL SECTION @ CANOPY (EXISTING) SCALE 3/8" 0 3/8`=1'-0" ARCHIT[CTURI [us I N T E R N A TI O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281,9299 Fax 813.281.9292 E—Mail api@architectureplus.com License #AAC001935 or(Kash n Pv'A Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- Z� ----------------------------------------------------- ------------------------------------------------- ------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC #50985 ------ GA ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------- #8343 SC #98033 1} ----- ----------------------------------------------- TO THE BEST OF THE IQJ &EDGE OF THE AC"TECTS aro Eta SAD PLAM APD SPHFCATUI S CLtuFLY WITH THE APPUCABLE MNMUM BULDNC' CODES AND THE APPUCABLE MNt" FIFE SAFETY STAroAfiB. KASH__N' __KARRY - NO. 1890 SANFORD,-- FL ------------------------- PROJECT NAME WALL_ SECTIONS ----------------- AND__DETAILS________________ SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: CE CHECKED BY: API SCALE: AS NOTED ISSUE DATE 9/OEC/O1 ----------------------------------------------------- ISSUE-FoR:-BID/PERMIT --------------------------------------------------- A0__4 ----------------- SHEET NUMBER ARCHITICTURI [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281.9299 Fax 813281,9292 E—Mail api@architecturep us,com License #AAC001935 F Kash n Karry OAS DATED ARICHITECTUREPLUS INTERNATIONAL, INC. Z_\� ------------------------------------------------ Z ----------------------------------------------------- zn� ------------------------------------------------- (REVISION LOG STATE REGISTRATIONS FL #AA001935 NC #50985 ----------------------------------------------------- GA ----------------------------------------------------- #8343 ---------------SC #98033---- 'U U ----------------------------------------------------- TO THE BEST OF TFE FQJDIMFDGE CF TFE AFCHITBCTS AND BVGNEEFA SAID PLANS APD S ECK-ATICN5 COMPLY WITH TFE APRJCAWE K"ALAA OULD G CGCG APD TFE APPLICABLE K4*lW FFE SAFETY STAMAFDS. COLUMN GRID LINE, REFER 5" TO CONSTRUCTION PLAN COLUMN GRID LINE, REFER I EXISTING STOREFRONT TO CONSTRUCTION PLAN I I SYSTEM TO REMAIN I I 3-5/8" METAL STUD TO I I 1-5/8" METAL STUD TO BOTTOM UNDERSIDE OF EXISTINGOF ..... ........... . NEW STUD WORK ABOVE { .... ..: .. : .. .. . ._ .--:.... _ ...:.. - -. CANOPY. (TYP.), BRACE BACK AS REQUIRED i EXISTING COLUMN AND BOX OUT TO REMAIN C 7 1-5/8" METAL STUD TO BOTTOM OF NEW STUD WORK ABOVE Ul EXISTING COLUMN AND BOX OUT TO REMAIN �n m 3/4" GEMENT PLASTER ON PAPER BACKED WIRE LATH ON 5/8" FRT CDX PLYWOOD (� 3/4" CEMENT PLASTER ON UP TO 3'-4" A.F.F. AND 5/8" M.R. PAPER BACKED WIRE LATH GYPSUM SHEATHING ABOVE L-1 ON 5/0" FRT CDX PLYWOOD UP TO 3'-4" AFF. AND 5/8" M.R. NEW GONG. CURB BELOW GYPSUM SHEATHING ABOVE 3-5/8" METAL STUD TO 21-611 NEW GONG. GURB BELOW 21-611 BOTTOM OF SOFFIT AND CEILING ABOVE (TYP.), BRAGE BACK AS REQUIRED LINE OF NEW CANOPY i I ABOVE LINE OF NEW CANOPY ABOVE *NOTE: VARIOUS SIZES IN METAL STUD FRAMING MAY BE *NOTE: VARIOUS SIZES IN METAL STUD FRAMING MAY BE REQUIRED TO ACHIEVE THE ILLUSTRATION SHOWN. REQUIRED TO ACHIEVE THE ILLUSTRATION SHOWN. NOT USED SCALE 5 COLUMN DETAIL (CANOPY) SCALE 4. COLUMN DETAIL (VESTIBULE) SCALE .1 4 E3 OL EL = 30-0" A.F.F.>4-4 � — — — EL = 30'-0" AFF T.O. NEW PARAPET/CORNICE � I T.O. NEW PARAPET BEYOND PROVIDE SINGLE PLY ROOF (HIGHEST POINT) SYSTEM ON 5/8" FRT CDX I PLYWOOD ON MTL STUD. REFER TO FLASHING DETAIL J I 1 ON 5/A-3. — EL = 2-1'-0 "AFF. EL = 21'-0" A.F.F. _ 3-5/8" EA. END Q 4'-0" O.G. T.O. NEW PARAPET BEYOND T.O. NEW PARAPET BRACING BETWEEN, W/ (3) 1'10 TEK EA. (LOWEST POINT) SIDE I I FASTEN 8" TRACK TO CMU W/ (2).14 DIA. PDF a 16" O.C. 3 NEW PARAPET I I 4-4 T.O. BRACING. REFER TO EL = 22'-S" A.F.F.I — NEW CORNICE DETAIL ON -1/A-10.T.O. NEW CORNICE BEYOND — — NEW 8" 20 GA. MTL STUD m 16"PROVIDE MTL. FLASHING I NEW 6" 20 GA. METAL STUDS 16" PROVIDE MTL. FLASHING O.C. MTL STUD W/L4x4x14GA.x4" REFER TO 3/A-3 1 D O.G. MTL. STUD W/L4x4x14GA.x4" REFER TO 3/A-3(6IM.) I LONG CLIP ANGLE W/2 0.14 MIN. LONG GLIP ANGLE (2) EA. TOP 4 DIA. 8 1 1/4" MIN LENGTH BTM. AND (1)4'-0" O.G. MAX. POWDER DRIVEN FASTENERS BETWEEN. FASTEN TO CMU W/(2) EXISTING ROOF INTO CMU AND 3 X12 TEK SCREWS EXISTING ROOF 0.14 MIN. DIA. 4 11/411 MIN LENGTH INTO STUDS 4'-0" O.C. C2 EA. m — I POWDER DRIVEN FASTNERS. TOP 4 BTM. AND 4'-0" O.C. FASTEN STUDS TO CLIP ANGLE EL = 18'-8" AFF BETWEEN). EL = 18'-8" AFF W/(3) 012 TEK SCREWS. 8.0. EXISTING J015T BRG. •. NEW EIFS ON 1 1/2" EPS ON 5/8" B.O. EXISTING J015T BRG. NEW EIFS ON 1 1/2" EPS ON 5/8" GLASS MATT SHEATHING ON MTL GLASS MATT SHEATHING ON MTL STUDS. STUDS. NEW CONTINUOUS FLASHING. REFER TO 6/A-3 NEW CONTINUOUS EXISTING HORIZONTAL I EXISTING HORIZONTAL 1 FLASHING. REFER TO JOINT REINF. AT EXISTING RAISED SIDE PARAPET JOINT REINF. AT 6/A-3 ALTERNATE COURSES BEYOND ALTERNATE COURSES EXISTING RAISED SIDE PARAPET BEYOND ° 1 NEW STANDING SEAM ROOF TO I NEW STANDING SEAM ROOF TO MATCH EXISTING. MATCH EXISTING. EL = 12'-0" AFF ° ° EXIST ACT CLG. a I NEW PREFINISHED DRIP EDGE EL = 12'-0" AFF EXIST ACT CLC. I NEW PREFINISHED DRIP EDGE EL = 10'-6" AFF EXISTING ROOF TRUSS EXISTING ROOF TRUSS OL EXISTING GWB CEILING - _ NEW EIFS FINISH ON 1-1/2" EPS ON EL = 10'-6 " AFF NEW EIFS FINISH ON 1-I/2" EPS ON GLASS MATT SHEATHING ON TO REMAIN " 5/8" GLASS MATT SHEATHING ON _/8" 3-5/8" MTL STUDS ON EXISTING 3-5/8" MTL STUDS ON EXISTING EXISTING CANOPY EL = 10' -0" A.F.F. EXISTING LINEAR FRAMING. CEILING TO REMAIN. EXISTING LINEAR FRAMING. HEAD (TYP) AIR VENT ,h EL = 9'-0" A.F.F.PATCH AND REPAIR TO ACCOMMODATE NEW AIR VENT EL = 9'-0" A.F.F. EXISTING BEAM B.O. NEW SOFFIT, NEW CONSTRUCTION AND EXISTING BEAM B.O. NEW SOFFIT, NEW LIGHT FIXTURE PAINT. LIGHT FIXTURE EXISTING HEAD TO BE 1 I I I III WRAPPED IN 1/2" GWB EXISTING VE8TI5ULE LOWCOLUMN 85OXEXISTING D AFTER STOREFRONT WALL TO REMAIN. EXISTING ALUM- FRAME - OUT TO REMAIN SYSTEM IS REMOVED. I I 2 CQ 1 / �10 NEW 5%. BOLLARD, REFER TO EXIST. STOREFRONT I I 11-61I 3/4" GEMENT PLASTER ON PAPER BACKED WIRE LATH GrESSRAL SAL & I CONSTRUCTION DETAIL SHEET 2/A-6. GLAZING TO REMAIN TYP) OVER 5/8 M.R. GYP. pj I I I SHEATHING ON MTL. STUDS (TYP) EL = 3'_ �� 5 1/2 A.F.F. EL = 3'- 5 1/2 A.F.F. EXISTING ALUM. FRAME NEW 3/4" x 3/4" CEMENT EXISTING SPLIT FACE - NEW 3/4" x 3/4" CEMENT X PROVIDE NEW GWB AND / / / PLASTER REVEAL CMU / / I I / PLASTER REVEAL 0 STUD AS REQUIRED TO EXIST. SPLIT FACE GMU TO III NEW S5%. BOLLARD, REFER W_ q F PATCH WALL. REFER TO FINISH SCHEDULE AND NIREP TO RECEIVE TO CONSTRUCTION DETAIL 9 NEW PAINT SHEET 2/A-6 dJ CONSTRUCTION DETAILS. EL = 0'-0" EL = 0'-01I EXISTING GONG_ SLAB I uuuuu OgL FINISH FLOOR EXISTING CON(_ SLAB FINISH FLOOR �oo0 000000 0 0 o o 0 T �O�O�O���r�-, �oo0 o 0 � 000000 0000 �OpOpOp�p�� EXISTING COMPACTED FILL o� 0 0 I EXISTING ASPHALT Op EXISTING COMPACTED FILL 0 0 0 0 � EXISTING ASPHALT FLUSH WITH EDGE OF FLUSH WITH EDGE OF EXISTING GONG. FOOTING I GONG. WALK (TYP) EXISTING GONG. FOOTING GONG. WALK (TYP) 1/4" INTERIOR MA LITE UP TO SILL, 1/2" GEMENT PLASTER ON WIRE LATH ABOVE OVER EXISTING SPLIT FACE BLOGK NOTE: AUTOMATIC DOORS ARE NOT SCHEDULED FOR REPLACEMENT. IF DECISION IS MADE IN THE FIELD THE FINISH 9 VESTIBULE INTERIOR ONLY. GENERAL CONTRACTOR SHALL CONTACT UNITED DOOR SERVICE AT 1-8-17-831-366l IF AUTOMATIC DOOR NOTE: AUTOMATIC DOORS ARE NOT SCHEDULED FOR REPLACEMENT. IF DECISION IS MADE IN THE FIELD THE PACKAGES NEED TO BE REPLACED- ALSO COORDINATE WITH THE KN'K CONSTRUCTION REP_ AND INSURE GENERAL CONTRACTOR SHALL CONTACT UNITED DOOR SERVICE AT I -Si -1-837-3667 IF AUTOMATIC DOOR THAT THE WORK IS COMPLETED PRIOR TO THE BOXING OUT OF THE CANOPY COLUMNS. PACKAGES NEED TO BE REPLACED. ALSO COORDINATE WITH THE KN'K CONSTRUCTION REP. AND INSURE THAT THE WORK IS COMPLETED PRIOR TO THE BOXING OUT OF THE CANOPY COLUMNS. WALL SECTION @ VESTIBULE NEW SCALE % WALL SECTION @ ENTRANCE (NEW) SCALE 1-011 ARCHITICTURI [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281.9299 Fax 813281,9292 E—Mail api@architecturep us,com License #AAC001935 F Kash n Karry OAS DATED ARICHITECTUREPLUS INTERNATIONAL, INC. Z_\� ------------------------------------------------ Z ----------------------------------------------------- zn� ------------------------------------------------- (REVISION LOG STATE REGISTRATIONS FL #AA001935 NC #50985 ----------------------------------------------------- GA ----------------------------------------------------- #8343 ---------------SC #98033---- 'U U ----------------------------------------------------- TO THE BEST OF TFE FQJDIMFDGE CF TFE AFCHITBCTS AND BVGNEEFA SAID PLANS APD S ECK-ATICN5 COMPLY WITH TFE APRJCAWE K"ALAA OULD G CGCG APD TFE APPLICABLE K4*lW FFE SAFETY STAMAFDS. KASH __N'_ _KARRY_ NO. -1890 SANFORD,---- FL -- - --- - - PROJECT NAME WALL_ SECTIONS _________________ AND__DETAILS ________________________ SHEET NAME PROJECT NILMER: 9949.01 ----------------------------------------------------- DRAWN BY: CE CHECKED BY: API - ---------------------------------------------------- SCALE: AS NOTED ----------------------------------------------------- ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE--FoR: -BID/PERMIT - ------------------------------------------------ -------------- A�_4_w_l SHEET NUMBER i ARCHITICTUR[ [US I N T E R N A TI O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com License #AAC001935 /,Dash n Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- I. GENERAL CONTRACTOR SHALL SPECIFY ................................................. ----------------------------------------------------- REVISION LOG INSULATING SAFETY GLASS TO WINDOW STATE REGISTRATIONS ----------------------------------------------------- FL ----- #AA001935 NC #50985 ------------------------------------------------ GA ----------------------------------------------------- #8343 SC #98033 MANUFACTURER. _____________________________________________________ TO THE BEST OF TFE R40M EDGE OF THE AfK:FHECTS AND aCNEE % SAD FLANS AND SPfCFCATICNS COMPLY WITH THE APPDCABLE Nl%&N BI.ID W CODES AND THE AFRJCABLE MNIMUM FRE SAFETY STAPDAfDS. 2. GENERAL CONTRACTOR TO PROVIDE METAL TRACK ON HOLLOW MWTAL FRAME (FRAME TO HAVE A THERMAL BREAK) AND BALL BEARING ROLLERS FOR SLIDING GLASS PANELS (USE INSULATING GLASS PANELS.) TYPICAL OF 4. EXISTING STOREFRONT EDGING STRIP ON GLAZING TO REMAIN. 3. ENTRE WINDOW AREA TO BE SEALED AIR TIGHT TOP OF 20 GA DONT. STL. 40" A.F.F. WITH RUBBER GASKETS, CAULKING, ETC. PLEXIGLASS NEW 0.032" MIN. ALUM. SILL SET AROUND COLUMN. PROVIDE IN BED OF MASTIC AND CORNER BEAD a EACH PLEXIGLASS SEALED W/BRONZE SILICON. CORNER. NEW 2X2 WOOD FOLD EXPOSED EDGE UP SIDE. ALIGN COLUMN BOX OUT CORNER POST BACK COLOR TO MATCH ".:.:.:-..:'-:.;:.:.. - WITH THE SOFFIT ABOVE ON W/GAP. SPACE tv EXIST. STOREFRONT. BOTH SIDES 3'-0" O.C. MAX.= 5/8" GWB XISTIN 8" GMU WALL STAIN TD MATCH �4 MARLITE COLOR. - EXIST. EXT. SILL CAP TO EXISTING COLUMN TD REMAIN REMAIN 1X6 WOOD STOOL - STAIN TO 1-5/8" METAL STUDS L _ EL=B'-10" AFF MATCH MARL ITE NEW P.T. WOOD BLOCKING ::: ' :: ' EXISTING ACT ° '" COLOR AS REQUIRED. E SOFFIT ABOVE WALL FINISH, REFER TO p FINISH SCHEDULE MARLITE - EXISTING SPLIT FACE BLOCK GROUT (2) COURSES TO REMAIN. n NEW 8"x8"X3/8" WELDED STEEL 4°: PLATE. BEAR 4" MIN. a EACH END. MARLITE ON GWB 1 5/8" MTL :" a 3/8"X511 FH ANCHOR tv 2'-0" O.C. STUDS ON EXISTING CMU. EL = 1'-4" AFF T.O. MASONRY OPENING NEW P.T. 2 "X1011 CASE WINDOW W/FINISH TO MATCH EXISTING. REFER TO FINISH SCHEDULE. A-10.1. CASE WINDOW W/F.R.P. TRIM ON THE MEAT PREP. SIDE MEAT SALES TO MATCH EXISTING CONDITIONS. DETAIL — PLEXIGLASS SCALE $ DETAIL — SILL FisliALE 7 DETAIL — COL BOX OUT SCALE ��1 T 1'-0" /2"=1'-0" 11/2"=1'-0" WINDOW, REFER TO SCHEDULE SHEET A-10. EL = 3' - 4" AFF CMU, OR METAL STUD OIL WALL B.O. MASONRY OPENING CERAMIC TILE WALL WALL FINISH, REFER TO NEW COL. BOX OUT. FINISH. REF TO FINISH I04A MEAT PREP FINISH �C HEDULE SCHED. SHEET A-10.1.HEET S 3/4" GEMENT PLASTER CERAMIC TILE BULL NOSE Wu I VARIES COVE BASE (REFER TO SINGLE DECK CASE CONT. SEALANT FINISH SCHEDULE) SHEET WALL FINISH. REF. TO FINISH A-10.1. SGNEO. 1/2" PREMOLDED EXPANSION I �� EXISTING STOREFRONT JOINT MAT'L. ON LOW WALL TO REMAIN E.L. = AS D IGTED METAL STUDS CONC. CURB SLOPE �� 5/8 GWB _ ..... ... .. LE�ATION AS a CONC. SLA SIDE WALK ,... > . . INDICATED S t _,p BA E OF ».•..... • '♦ ALIGN COLUMN BOX OUT - . ,. e.: .. -. b.' , 'r CURB „. WITH THE SOFFIT ABOVE ON — — — BOTH SIDES :...:.,,::.. CERAMIC TIL FLOOR R .�• '.k''' ,. .' ''; (REFER TO FINISH EXISTING SOFFIT ABOVE SCHEDULE) SHEET A-10.1. EXISTING AUTOMATIC d----- LOW WALL AND STORE ----- ---.--zt—�------- SETTING BED. REF. TO FRONT TO BE REMOVED NEW BREAK METAL a 4 FINISH SCHED. EXISTING CONCRETE - EL = 0 011 AFF SLABa a d "d ° °� FINISH FLOOR a` d *4 DOWEL AT 24" O.G. CERAMIC TILE DETAIL �,O O O O O^O„O^O,.O O O, ,O�,O, ,O, ,O O PLAN VIEW NOTE: AT METAL STUD WALL-DUROCK TO 4'-0" AND M.R. GYP. BD ABOVE DUROCK. jCB2_ CB1 DETAIL — EDGE CLOSURE SCSLE 5 DETAIL — CURB TYPES SCALE 4 DETAIL — MEAT PREP WIN SCALE 1 0 N.T.S. 1 — 1'-0" I MTL. STUD BRACING/ ROOF DECK ABOVE 8" KICKER a 4'-0" O.G. MAX. BOLLARD TYPES I 3 5/8" METAL STUD FRAMING ® 6" DIAMETER STEEL PIPE e 16" O.G. W/CHANNEL CONT. 3-5/8" MTL. TRACK A BOLLARD - CONCRETE 2 X 4 WELDED WIRE MESH FILLED i FASTEN W/SHEET METAL LOCATION: AT VESTIBULE SCREWS 4 WASHERS. EL. = VARIES ENTRY COLUMNS EL. - AS INDICATED - •4' O 2" DIAMETER STEEL PIPE f.. f SEL. = 8'-6" AFF. ROOF DECK ABOVE -------- GLC. NT. BOLLARD - CONCRETET.O. GWB 3 5/8�� 20 GA. METAL STUD CLG. (AS SPEC.) FILLED LOCATION: ELECTRICAL �4 I FRAMING 16" O.G. { cr1 WATER COOLER MTL. BRIDGING TO ROOF DECK ABOVE. BETWEEN STUDS 1 I 2 X 4 WELDED WIRE MESH PRo[=E PREP. CLG. (AS SPEC.) FASTEN W/SHEET METAL FINISH PAVING SCREWS 4 WASHER I } FIBERGLASS REINFORCED t PANELS ON 5/8 FRT CDX EL. = MATCH W/T.O. PLYWD. ON 3-5/8 METAL STUD °•''a• 3 5/8" METAL STUD FRAMING PLAN i ADJ. CMU WALLS FRAMING m 16" O.G. 16" D.G. W/CHANNEL " b 1/2" GWB Ln •a " •. �. 3 5/8" 20 GA. METAL EXISTING CMU WALL. 2-0 '. .. DIA. STUD FRAMING 4.. • :: ` `' CON. FTG. ( l6 " O.C. 4 PT 1X6 WOOD BASE. BASE/CURB (AS SPEC.) BASE/CURB (AS SPEC.) OLEL. = 0'-01' PLAN VIEW FIN. FLR.SEL. = 0'-0" P3 FP2 FP1 DETAIL — BOLLARD (TYP.) SCALE 2 DETAIL — PARTITION TYPES SCALE 1 10 1 1/2" = 1'-0" ■ ARCHITICTUR[ [US I N T E R N A TI O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com License #AAC001935 /,Dash n Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- ................................................. ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL ----- #AA001935 NC #50985 ------------------------------------------------ GA ----------------------------------------------------- #8343 SC #98033 _____________________________________________________ TO THE BEST OF TFE R40M EDGE OF THE AfK:FHECTS AND aCNEE % SAD FLANS AND SPfCFCATICNS COMPLY WITH THE APPDCABLE Nl%&N BI.ID W CODES AND THE AFRJCABLE MNIMUM FRE SAFETY STAPDAfDS. KASH N' KARRY NO. 1890 SANFORD,----- L ______________________ PROJECT NAME PARTITIONS TYPES & CONSTRUCTION DETAILS__ SHEET NAME PROJECT NUMBER 9949.01 DRAWN BY: PH CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ISSUE FoR: BID/PERMIT ----------------- A-__6 ------------------ SHEET NUMBER s Y 12" 12" 12" 12" -rY T L. . lu I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813.281.9292 E—Mail api@architecturepus,com 12" 12" 12" 12" TY TY II II A DALTILE-OCEAN BLUE -DI -{-49 l4 X 4) D D REVISION LOG A5L7-),4LT1LF=-GANVA5- OIL EL = 8' - lm" A.F.F. ----------------------------------------------------- FL #AA001935NC #50985 EL = 8' - �" A.F.F. � 8343 p -13-i C4" X �") EXIST. ACT. CLG. NT. / / AE EXf 5T. ACT. CLC. HT. _ _ Ar - Ac - � DALTILE= BOTTLE GREEN= Q=179 C4" X 4"> — A A 00 0 0 0o IE I - o0 0 0 00 AD pALTILE-GNAI"IOIS- �-180 C4" X 4") Ac; -� AE DALTfLE-DENIM-DH-I-� C4" X 4") G � pALTILE- WOOp VIOLET -p-146-1 C4" X 4") O � OARCHIT[CTURI AG O 0 DALTfLE- DAL -WHITE -ID -D-100 C4" X 4") ►— u �- TILE PATTER N DETAIL B TILE PATTERN DETAIL A GROUT COLOR: WHITE MEAT & SEA FOOD SALES DELI. &BAKERY SALES TILE PATERNS DETAILS LE CERAMIC TILE LEGEND NTS GENERAL SALES AREAS PAINTED GWB, INCLUDING AREA OPEN TO SALES lll�i CUSTOMER SERVICE, IOOF, 100G VESTIBULES) F a c B 8' TO CEILING ICI 6�1 "LAURENS LACE" FLAT BELOW 8' ICI 382 "KENYA CORAL" SATIN 14 T`1 P. 2 T TYP. T `F I I I I I I I I I I I I I I I I I I I I I I I I 11 I I I I I I 1 II 5. - GJ 0 AFF. B.o. EXST. CANOPY J. ICI 15-16 "ULTRAMARINE" SATIN. -- _ — — — _ _ — _ — — — — — — — — — — — — — — — — — — — — — — — — — — — — 1T — — — — — — — — —Ir — — .-�w.11��.l.-ALL 1 — — +-+i �1Jv�14�-J1-X11.-.-1Lw.11.�-ii--ii I I I TYP I I I PREFIN. MED. DENSITY FIBERBOARD ____________ __r J� I MARLITE WOODGRAIN COLLECTION - " DESIGNER SERIES PLANK z4' COLOR: 323-52 "PLANTATION" 15 TYP- I FROZEN FOOD AREA I I PRODUCE AREA 3 EXISTING STEEL COLUMNS AT GENERAL SALES AREA ICI -134 "BAKER WHITE" RIGHT ELEVATION D FRAMES AT TRAFFIC DOORS ICI -382 "KENYA CORAL" SATIN. INTERIOR 4 EXTERIOR HOLLOW CORE DOORS FRAMES AND DOORS IGI-151(o "ULTRAMARINE" SEMI -GLOSS GUARDS MFR Mr -CUE COORPORATION/MDL. C,62-120-FWALL-401 10 VESTIBULE CG5-10 $ CGT -10 w ALL OTHERS 2A c v e F CART BUMPER 4, AT 2'-10" A.F.F. A-1 COLOR: McGUE X149 "LAVENDER" EL = 12' - 0" AFF, 0-800-800-8503) 11 9 I I I 2 I I EXIST. ACT. CLCs. HT. TYP.. TYP. TYP. ----------- -------------------- EL = 8' - 10" AFF. EXIST. ACT. CLC. HT. INTERIOR COLOR SELECTION ---- -------------------- -------------------- — — — — — — (BEHIND) --------— _ I I I EL = aI - 0" Ar -F. v — — —EM, I B.O. EXST. CANOPY 1. NO PAINT OR WALL FINISH REQUIRED. �I 1 11 111 }` EL = 0' - mll FF 2. PAINTED GWB. SEE INTERIOR COLOR SELECTION ABOVE. I I I I 1 15 3. APPROXIMATE MIII MATE LINE OF FIXTURE/EQUIPMENT FOR RELATIONSHIP TO 13 TYP I I SERVICE AREA CUSTOMERBAKERY/DELI AREA GENERAL SALES AREA DAIRY AREA " 4. NEW GWB FINISH AT VESTIBULE TO BE PAINTED, IC1382 KENYA CORAL" SATIN. LEFT ELEVATION r+ V 5. STAINLESS STEEL COLUMN WRAP UP TO 4m" A.F.F. REFER TO DETAIL A-6. 6. WALL MOUNTING W/BRACKET CART BUMPER AT 2'-10" AFF MODELO=CS2-120 F WALL -401. COLOR: -1413 "LAVENDER" AT VESTIBULE WALL ONLY. I 2 3 2 4 6 6 -1. DASHED LINE INDICATES APPROXIMATE LINE OF MILLWORK. 14 A-1 18 9 2 EL = 12' - 0 APF. 1=xlsr. ACT! c��. Hr. 8. FOAM MOLDING (N.LC.). REFER TO SIGNAGE 4 DESIGN DECOR TYP. I I I I PACKAGE. EL - 8' - 1m" AFP 9. SUSPENDED CEILING EDGE TRIM, REFER TO ENLARGED PLANS SHEET EXIST. ACT. CLG. HT. A-14 (BEHIND) I I I I / I EL = 8' - 011 AFF. 10. SUSPENDED ILLUMINATED DEPARTMENT SIGNAGE (N -1-C.). REFER TO EXST. CANOPY SIGNAGE $ DESIGN DECOR PACKAGE. / I EL 0' - 0 F.F. 11. HANGING MAGNETIC SIGNAGE (N.I.C.). REFER TO SIGNAGE 4 DESIGN zq' 24 DECOR PACKAGE. MEAT AREA 15 12. BASE MOUNTED MAGNETIC SIGNAGE (N.I.C.). REFER TO SIGNAGE 4 MEAT/SEAFOOD AREA LUNCH MEAT AREA DECOR PACKAGE. 13. PREFINISH MED. DEN. F1BERl30ARD "MARLITE" WITH EDGE TRIM WHERE REAR ELEVATION B REQUIRED. WAINSCOT TO 40" UNLESS OTHERWISE INDICATED. 14. HANGING SIGNAGE BANNER(N.I.C.). REFER TO SIGNAGE 4 DESIGN DECOR PACKAGE. 15. PREFINISH MED. DEN. FIBERBOARD "MARLITE" UP TO BOTTOM OF EXIST. CEILING HEIGHT. PROVIDE END TRIM - 69 3 2 I 1(o. EXISTING STEEL COLUMNS TO BE PAINTED. REFER TO INTERIOR COLOR SELECTION ON THIS SHEET. BEYOND ANGLE oFFI 2A 2 19 4 g 1_1 A-1 1� EL = - 0" A.F.F. HT. 1-1. EXHAUST HOOD. . EXIST. ACT. CLC. II TYP. I I I 18. EXISTING WINDOW AT MEAT/SEAFOOD PREP. AREA. 11Y I I I II II II II II II II II II II II II II 1L.. LE '1� I I I _ _ __ I I _ EL = a� - 0" AF.F. 19. SENSORMATIC CONTROL BOX IN.I.GJ. REFER TO ELECTRICAL DWCxS. r J flu itiumll, EXST. CANOPY B.O. I�—r------------ -- --- I I Erg: EL = 0'- 0" FF. I I II z� 13 I 5 6 I I I PRODUCE AREA TYP TYP DELI/BAKERY AREA FRONT ELEVATION q INTERIOR ELEVATIONS��,s/cAL%0.1 1 REFERENCE NOTES O 14 TYP. 8 TYP. 12 TYP. 10 EL = Ir - 0" APP. I' SUSPENDED CEILING EDGE TRIM (AXIOM) License #AAC001935 I I I I exlsT. ACT. CLC. Hr. m 8'-0" AFF -(WHITE) I -,.-Y-Y-., ., _ MOULDING AT 8'-0" AFF I ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- A------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935NC #50985 ----------------------------------------------------- GAJ ----------------------------------------------------- 8343 U� ----------------------------------------------------- TO TFE BEST CF TFE KNOALEJGE CIF TFE ARCH ECTS AND El"EFR SPD RAMS PAD SPEC IFCARM CIDWLY MA TFE APRJCAB E MMAJM BULLING CODES AND TFE APPLICABLE MMAUM FFE SAFETY SfAKDAHS. KASH N' KARRY NO. 1890 ----------------------------------------------------- SANFOR®,-- FL------------------------- PROJECT NAME INTERIOR ELEVATIONS SHEET NAME PROJECT NUMBER 9949.01 DRAWN BY: DR CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE FoR: BID/PERMIT ----------------------------------------------------- ----------------------------------------------------- SHEET NUMBER 0 Y NG PREFAB 117(D/BAELIIKERY FREEZER �� TRUE NORTH PLAN NORTH REFLECTED CEILING PLAN SCALE10 v EXISTING 24" X 4811 RECESSED FLUORESCENT LIGHT FIXTURI=. EXISTING 24" X 48" RECESSED FLUORESCENT LIGHT FIXTURE TO BE RELOCATED. ® NEW 24"X48" OR 24"X24" RECESSED FLUORESCENT FIXTURE. EXISTING B' OR 4' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE TO REMAIN AND BE REBALASTI=D AS T-66 AND REFLECTORS ADDED. REFER TO ELEC. DWGS. NEW 4' OR 8' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE. NEW SUSPENDED LIGHT TRACK AND TRACK FIXTURE HUNG FROM STRUCTURE ABOVE TO 9'-0" AFF UNLESS OTHERWISE NOTED. LENGTH OF TRACK AS INDICATED. �°— NEW SUSPENDED SOFTER LIGHT TRACK AND TRACK FIXTURE HUNG FROM STRUCTURE ABOVE TO 9'-0" AFF UNLESS OTHERWISE NOTED. LENC:sTH OF TRACK A5 INDICATED. NEW RECESSED HID FIXTURE. NEW EXTERIOR WALL MOUNTED UP/DOWN HID FIXTURE. NEW EXTERIOR RECESSED HID FIXTURE. EXISTING SURFACE MOUNTED WALL WASHER FIXTURES TO BE REUSED AS CASE TOP WALL WASHER. MOUNT 6" FROM BACK OF CASE TO (t OF FIXTURE. O NEW RECESSED 6" ROUND BIAXIAL FLUORESCENT FIXTURE. NEW 5U5PENDED FLUORESCENT LIGHT FIXTURE 1w 9'-011 AFF CENTERED ON REGISTERS BELOW. SUPPLIER DIFFUSER. NOTE: REFER TO ELECTRICAL DRAWINGS FOR FIXTURE SPECIFICATIONS. REFER TO FINISH SCHEDULE FOR ACT TYPES. FIXTURE LEGEND 1. NO ACT/GWB GLG. AT EXHAUST HOOD. NO SPRINKLER HEADS TO BE INSTALLED OVER THIS RACK OVEN. COORDINATE INSTALLATION OF THIS UNIT WITH THE KN'K CONSTRUCTION REP. 2. GENERAL CONTRACTOR TO PROVIDE FRP FILLER PANEL FREEZER WALL TO MATCH COLOR AND FINISH AS REQUIRED TO FILL GAP CIF ANY) BETWEEN TOP OF FREEZER AND NEW ACT CEILING. 3. EXISTING STEEL ACCESS HATCH TO BE REPAINTED. INSURE NEW CONSTRUCTION DOES NOT INTERFERE WITH OPERATION OF HATCH AND ACCESS TO INTERIOR OF CANOPY. 4. EXISTING ACT. AND GRID TO REMAIN. CLEAN TILE AND GRID. REPAINT (TOUGH -UP PAINT) AS REQUIRED. COORDINATE W/KN'K CONSTRUCTION REP. 5. PATCH GWB CLG. AS REQUIRED AND REPAINT WITH SHERWIN WILLIAMS PURE WHITE EPDXY, "SW 1004, MINIMUM 2 COATS. 6. NEW "AXIOM" EDGE BAND AT 5'-0" A.F.F.REFER TO ENLARGED PLAN SHF=I=T A-14 FOR EXACT LAYOUT AND DETAIL. 1. APPLY NEW FINISH TO REMAINING SOFFIT AFTER STOREFRONT IS REMOVED. REFER TO WALL SECTION SHEETS A -4/A-4.1. S. NEW TRACK LIGHT HUNG FROM STRUCTURE ABOVE MATCHING THE HIGH OF THE TRACK LIGHT UNDER THE DELI/BAKERY "AXIOM" EDGE. 9. FOAM MOLDING (N.I.C.) REFER TO SIGNAGE AND DESIGN DECOR PACKAGE. 10. EXISTING SOFFIT TO REMAIN AND TO BE REPAINTED. PATCH TO MATCH AS REQUIRED. ll. CEILING GRID TO BE LAID OUT FROM ROOM CENTER LINE BOTH DIRECTIONS (U.ON.). 12. EXISTING GRIP TO BE GLEANED AND PAINTED. PROVIDE NEW ACT. 13. PROVIDE NEW GRID AND ACT. IN THIS AREA. PAINT GRID TO MATCH EXISTING GRID AT SALES AREA. 14. GENERAL CONTRACTOR SHALL EXTEND 5PRINKLER SYSTEM INTO EXTERIOR CANOPY CEILING. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING TO PROPER AUTHORITY, SPRINKLER SYSTEM DRAWINGS FOR APPROVAL. 15. PAINT NEW CEILING WITH SHERWIN WILLIAMS PURE WHITE, EPDXY # SWI004, MINIMUM 2 COATS. REFERENCE NOTES O 1. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR CENTERLINE OF COLUMN UNLESS OTHERWISE NOTED. 2. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH DRAWINGS AND SPECIFICATIONS OF ALL APPLICABLE TRADES AND ENGINEERING DISCIPLINES. 3. CONTRACTOR TO COORDINATE THE LOCATION OF SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES AND COILS IN ALL AREAS. 4. DASHED LINES INDICATE EQUIPMENT/FIXTURES BELOW. 5. THE CONTRACTOR SHALL FURNISH TWO BOXES OF CEILING TILE FOR EVERY TYPE OF TILE USED IN THE STORE. LEAVE TILE AT THE STORE FOR FUTURE USE. (SEE SPECIFICATION BOOK.) C . ALL VISIBLE CEILING MOUNTED REGISTERS, PLATES 4 GRILLES (ELECTRICAL, MECHANICAL, SPRINKLER, ETC.) SHALL HAVE A WHITE FINISH UNLESS OTHERWISE NOTED. 7. INSURE THAT LIGHT FIXTURE AND ACT METAL SUSPENSION GRID CLEARS COLUMNS, GWB. HEADER AND HOOD ENCLOSURES. 8. IN AREAS WHERE EXISTING LIGHTS ARE BEING REMOVED THE EXISTING GRID TO REMAIN SHOULD BE REPAIRED TO MATCH EXISTING CONDITIONS. 9. GENERAL CONTRACTOR TO ENSURE THAT ALL EXISTING PREFRABICATED LINEAR AIR VENT AT CANOPY AREA ARE CLEANED AND REPAIRED AS REQUIRED. 1 I GENERAL NOTES ARCHITICTURI 1V IN T E R N A T 10 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281,9299 Fax 813,281.9292 E—Mail api@architectureplus.com License #AAC001935 r Dash n' harry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ------------------------------------------------- ------------------------------------------------- ------------- Y REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL ---------------------------------------------------- #AA001935 NC_ #50985 GA #8343 SC #98033 ----------- 01 ----- ----------------------------------------------- TO THE BEST OF Tl E aMLEDGE OF TIE AK; - OiB AND UCMEFB, SAD RMB AND SPECFICATKM COWLY WTTH THE APPLICABLE NIRAN BLAS OOOES AND THE AFR.ICAM MNIN ,1 FPE SAFETY STAPDAFDS — 5.9 Le pC4 L O r� Iii I I I T P. lI1'L. XI TIN EI IN 1 - Jul T IN - I I I I 14 N EXISTING EXPOSED TO I I Ijl ISI 1 i LNJSTORAGE I I 1 102A PRODUCE r_J lm3 FREEZER COOLER 1 ; 1 I I 12 L 1 L STRUG. ABV. TO REMAIN 105 CORRIDOR "1 �: EL: 6-0" A.F.F.' . OL EL: -011 Ar -P. o EXISTING PREFA J EXISTING PREFA 1^I — — _ 5 ' I ISI 2 I t I I t I I LTJ I 1 5 4.8 I I l 0 1 r —_ EL: 8'-0" AFF. I I I I 5AG3 — G3-120 L — EXISTING PREFA — — „u I 1048 MEAT/SEAFOOp COOLER � I EL: V-01' AFF. I I I EXISTING PREFAB I Q 1 1 I I I d 1 I 104E TRAY COOLER qct -4 � 1 _J J I' I 0I IBA MEAT/ AFOOD P. I 1 10 I — 42 I _ I EL: 10'-01' FF. '1 I I T 15 IM IN I I = L 1 r EXISTING _ FAB ni 1♦ i ' c– �, I Q I I I 1 — 1 1 IL_ 11 1 IQ 1-; I -- ExkT�S APtDOf'E Z R !A I If PT — 3.9 -� I e --� TI _ 1_ 11 EL: 0 FF. I I uil 1 I i �• i EXI TING REFAB I I 1 uiu I � I I I L__J — — GEE 106 RECEI INC 1 101 ANITOR I.�. I 1 _ I OW (T T— lm EX TING CEILING' 1 I _ I L; 12' 0" AFT I I B EXISTING XPOSED TO TO REMAIN �' \� X STI G 0 RE AI INC CEILING IF STRUC. A V. TO REMAIN O EAT STORAGE r---------� 104D r--� EX -TING CEILING I I I TO TO REMAIN VESTIBULE t0 Mjyj� I I I I L ---------J --L Os I lm - - 100 I O r--_� __-� I 1 l LI=CTRICAL '04 J 31 O 108 , II I I EXISTING CEILINGt) -- -- -- — -- -- — TO MAIN 1 EXISTING CEILING L-_' i i I O I TO REMAIN -- -- CUSTOMER IIS OUNCE I 109 I 4 1 I _ -' i 1 SERVICE I EXISTING CEILING OSED TO 1' I ; ; EXISTING CEILING O I L ezr__ __ _ ---- I OFFICE STRUC. ABY. TO _ GROCERY STORAGE F__� TO MAIN I 1,i . i I18A 110 I I I I u 1___jI � EL: W-0" AFF I I ® I I I I I 142.4 I 2 5 PLYW EPDXY PAINT WHIT I _ _ _ _ _ 1148 PC TRAINING ROOM 1 — _ — — — — — — _ _ I EL: W-011 AFF r- II I I I I 1 I J I� I EXISTING CEILING TO REMAIN GWB/EPDXY PAINT WHITE WOMEN'S ROOM 116 0 I _ 1 L I 1 I OFFICE StORAG 1188 EL: S'-0" AFF I I Ill DAIRY COOLER I —�4� I 4 I I , ,11 1 R O GWB/EPDXY PAINT WHITE MEN'S ROOM 115 EXISTING CEILING 1 r� 2 I OIL TO REMAIN I YAA3-_ ELI K Y A E ' I - - - Yui J I LIL- I EXISTING PREFAB INTERVIEWING I I I I 1- 1 1 NJ I 11IB DELI/13AKERY 114A ROOM r` M t t L; g_ F 0 I i i Cl X I 5 COOLER OgL EXISTING CEILING TO REMAIN- I --� I 1 I 1 I DELI/BAKERY L; : �; `•� J 112 STORAGE F-- RAG5-180 �I I 4 OIL EL: V-0" A.F.F. 15 l �) 15 — — — — - — T2 _ _ .- _ = h - -- EL: S'-611 AFF. ExiDELI/BAKERYA EXISTING PREFABW-11-1-1 113 ICE CREAM FREEZER 2 I I 9 I I __ 1 rl = L L IIlA ABY7 1 1 PREP. O EXISTING CEILING 13 11 8 8, - - TO REMAIN e I ---- - - - -- -- - I I I •� -- LsAG3 T2 _0 - 3 114 SECURITY ROOM I I EL: 8'-0" AFF. EXIS ING CEILING 1 ACT. #3 I I I TO REMAIN 105A CORRIpOR #2 IIID DELI AKERY CLOSET I _ k EL: 8'-0" AFF. Y NG PREFAB 117(D/BAELIIKERY FREEZER �� TRUE NORTH PLAN NORTH REFLECTED CEILING PLAN SCALE10 v EXISTING 24" X 4811 RECESSED FLUORESCENT LIGHT FIXTURI=. EXISTING 24" X 48" RECESSED FLUORESCENT LIGHT FIXTURE TO BE RELOCATED. ® NEW 24"X48" OR 24"X24" RECESSED FLUORESCENT FIXTURE. EXISTING B' OR 4' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE TO REMAIN AND BE REBALASTI=D AS T-66 AND REFLECTORS ADDED. REFER TO ELEC. DWGS. NEW 4' OR 8' SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE. NEW SUSPENDED LIGHT TRACK AND TRACK FIXTURE HUNG FROM STRUCTURE ABOVE TO 9'-0" AFF UNLESS OTHERWISE NOTED. LENGTH OF TRACK AS INDICATED. �°— NEW SUSPENDED SOFTER LIGHT TRACK AND TRACK FIXTURE HUNG FROM STRUCTURE ABOVE TO 9'-0" AFF UNLESS OTHERWISE NOTED. LENC:sTH OF TRACK A5 INDICATED. NEW RECESSED HID FIXTURE. NEW EXTERIOR WALL MOUNTED UP/DOWN HID FIXTURE. NEW EXTERIOR RECESSED HID FIXTURE. EXISTING SURFACE MOUNTED WALL WASHER FIXTURES TO BE REUSED AS CASE TOP WALL WASHER. MOUNT 6" FROM BACK OF CASE TO (t OF FIXTURE. O NEW RECESSED 6" ROUND BIAXIAL FLUORESCENT FIXTURE. NEW 5U5PENDED FLUORESCENT LIGHT FIXTURE 1w 9'-011 AFF CENTERED ON REGISTERS BELOW. SUPPLIER DIFFUSER. NOTE: REFER TO ELECTRICAL DRAWINGS FOR FIXTURE SPECIFICATIONS. REFER TO FINISH SCHEDULE FOR ACT TYPES. FIXTURE LEGEND 1. NO ACT/GWB GLG. AT EXHAUST HOOD. NO SPRINKLER HEADS TO BE INSTALLED OVER THIS RACK OVEN. COORDINATE INSTALLATION OF THIS UNIT WITH THE KN'K CONSTRUCTION REP. 2. GENERAL CONTRACTOR TO PROVIDE FRP FILLER PANEL FREEZER WALL TO MATCH COLOR AND FINISH AS REQUIRED TO FILL GAP CIF ANY) BETWEEN TOP OF FREEZER AND NEW ACT CEILING. 3. EXISTING STEEL ACCESS HATCH TO BE REPAINTED. INSURE NEW CONSTRUCTION DOES NOT INTERFERE WITH OPERATION OF HATCH AND ACCESS TO INTERIOR OF CANOPY. 4. EXISTING ACT. AND GRID TO REMAIN. CLEAN TILE AND GRID. REPAINT (TOUGH -UP PAINT) AS REQUIRED. COORDINATE W/KN'K CONSTRUCTION REP. 5. PATCH GWB CLG. AS REQUIRED AND REPAINT WITH SHERWIN WILLIAMS PURE WHITE EPDXY, "SW 1004, MINIMUM 2 COATS. 6. NEW "AXIOM" EDGE BAND AT 5'-0" A.F.F.REFER TO ENLARGED PLAN SHF=I=T A-14 FOR EXACT LAYOUT AND DETAIL. 1. APPLY NEW FINISH TO REMAINING SOFFIT AFTER STOREFRONT IS REMOVED. REFER TO WALL SECTION SHEETS A -4/A-4.1. S. NEW TRACK LIGHT HUNG FROM STRUCTURE ABOVE MATCHING THE HIGH OF THE TRACK LIGHT UNDER THE DELI/BAKERY "AXIOM" EDGE. 9. FOAM MOLDING (N.I.C.) REFER TO SIGNAGE AND DESIGN DECOR PACKAGE. 10. EXISTING SOFFIT TO REMAIN AND TO BE REPAINTED. PATCH TO MATCH AS REQUIRED. ll. CEILING GRID TO BE LAID OUT FROM ROOM CENTER LINE BOTH DIRECTIONS (U.ON.). 12. EXISTING GRIP TO BE GLEANED AND PAINTED. PROVIDE NEW ACT. 13. PROVIDE NEW GRID AND ACT. IN THIS AREA. PAINT GRID TO MATCH EXISTING GRID AT SALES AREA. 14. GENERAL CONTRACTOR SHALL EXTEND 5PRINKLER SYSTEM INTO EXTERIOR CANOPY CEILING. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR SUBMITTING TO PROPER AUTHORITY, SPRINKLER SYSTEM DRAWINGS FOR APPROVAL. 15. PAINT NEW CEILING WITH SHERWIN WILLIAMS PURE WHITE, EPDXY # SWI004, MINIMUM 2 COATS. REFERENCE NOTES O 1. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR CENTERLINE OF COLUMN UNLESS OTHERWISE NOTED. 2. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH DRAWINGS AND SPECIFICATIONS OF ALL APPLICABLE TRADES AND ENGINEERING DISCIPLINES. 3. CONTRACTOR TO COORDINATE THE LOCATION OF SPRINKLER HEADS, DIFFUSERS, LIGHT FIXTURES AND COILS IN ALL AREAS. 4. DASHED LINES INDICATE EQUIPMENT/FIXTURES BELOW. 5. THE CONTRACTOR SHALL FURNISH TWO BOXES OF CEILING TILE FOR EVERY TYPE OF TILE USED IN THE STORE. LEAVE TILE AT THE STORE FOR FUTURE USE. (SEE SPECIFICATION BOOK.) C . ALL VISIBLE CEILING MOUNTED REGISTERS, PLATES 4 GRILLES (ELECTRICAL, MECHANICAL, SPRINKLER, ETC.) SHALL HAVE A WHITE FINISH UNLESS OTHERWISE NOTED. 7. INSURE THAT LIGHT FIXTURE AND ACT METAL SUSPENSION GRID CLEARS COLUMNS, GWB. HEADER AND HOOD ENCLOSURES. 8. IN AREAS WHERE EXISTING LIGHTS ARE BEING REMOVED THE EXISTING GRID TO REMAIN SHOULD BE REPAIRED TO MATCH EXISTING CONDITIONS. 9. GENERAL CONTRACTOR TO ENSURE THAT ALL EXISTING PREFRABICATED LINEAR AIR VENT AT CANOPY AREA ARE CLEANED AND REPAIRED AS REQUIRED. 1 I GENERAL NOTES ARCHITICTURI 1V IN T E R N A T 10 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281,9299 Fax 813,281.9292 E—Mail api@architectureplus.com License #AAC001935 r Dash n' harry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ------------------------------------------------- ------------------------------------------------- ------------- - - - - ------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL ---------------------------------------------------- #AA001935 NC_ #50985 GA #8343 SC #98033 ----------- 01 ----- ----------------------------------------------- TO THE BEST OF Tl E aMLEDGE OF TIE AK; - OiB AND UCMEFB, SAD RMB AND SPECFICATKM COWLY WTTH THE APPLICABLE NIRAN BLAS OOOES AND THE AFR.ICAM MNIN ,1 FPE SAFETY STAPDAFDS KASH N' KARRY N0. 1890 SANFORD,-- FL ------------------------- PROJECT NAME REFLECTED --- CEILING----------- PL-AN ------------------------------------------ SHEE --------- PLAN------------------------------------------ SHEET NAME PROJECT NUMBER: 9949.01 ----------------------------------------------------- DRAWN BY: DR CHECKED BY: API ----------------------------------------------------- SCALE: AS NOTED - ---------------------------------------------------- ISSUE DATE: 9/06/01 ISSUE FOR: BID/PERMIT ----------------------------------------------------- ----------------- A_-__9 ------------------ SHEET NUMBED I I I 1 I • 10 1 CORRIpOR {'1 I 110 GROCERY STORAGE 1148 PG TRAINING ROOM 116 WOMEN'S ROOM 115 MENS ROOM 114A INTERVIEWING ROOM 112 DELIBAKERY STORAGE 113 ICE CREAM FREEXER 114 SECURITY ROOM } r ------ii U r------- i ----------------------------------------------------- 6 I I I I I I I I _________________________________________________ ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL --- #AA001935-------- NC_ #50985 ---------- GA #8343 SC #98033 ----- ----------------------------------------------- TO T}f BEST OF 11-E WM-EDGE OF TFE AflD4TWFS AND HVGt4EH� SAO RlNS AAD 5TJUICATONIS LOWLY WITH THE ARPJCAaE NWW.0 BI.IQNG CODES AND TFE AFPUCAE E MNMW FIFE SAFETY STAhDAFDS. I r �i I I_ T 7 -I- T- rt -I- T 1 1 1 1 1 1 I I I I I I I I I I I -I-i--I-i--I---I-I-a-I_L�-I-L1-1_L I T, -i-- �-�_�- I I I � �-}� I I I `{ -I I I I I 1 1 1 1 11 1� 1�,�1 1 1 � 1.,�I 1 1 1 � �- 'N �`'N la I I I I I II I I -I- 1 -1 1,� -1- -k-- _}��- I 7+ I I I I I I -I- �.,� J`I I �,-�I - �� � - �-L�-�=1- I I I I I I -1 -I- - � L I I -I- � Y I I 1_I_I 11 L1_I_ _ L_ I I I I �27pt U E f� .I I I I I I �t� R E 1-1- T- T T- T M AIS° I I I I I I I+ ��- > T- T j� �t I I I I I+ T_T I- I I I T i- S 1 1 1 1 1 -t -I + I T I I I I I I I I I ,1 I I I I1 1 _T -I -T --I-fi t -I- -I-+- -I- 1_I I l rR -L L1__ 2) • 1_I_ 1_I_L1-1_L1-I_L1-1_L1_I_L1 I_L1 I_L1_I_L1_I_L1_I_�1_I_L �, ,�-T-I- �►��, __�� �� _I_ I I I 11 I I -I-L _I_ I I _I_ I I _I-+ I _I_ I +_I- I I I I I I I I LL I I I I I I I I �� -1 -I- f tl- -I- I- jJ- +�9- -I -I- I- -li -1-1- - f- fi14-I- J I_I�I- -� -I- { t -{ -I- f�� -I- I-I_� I i-I-� I- I�I_L I -I-1 + H -I- F- I r -} -I �%' 1 I,;6, ` } k %' T �` r�`i t1- �� %'�' I TT ' 5 1 I I -I_I� I �_� + T- _ - T- -Lr II -1- _IU L 11-I-1TI I -I— - _I_�I IY I I I'%6� I�� I, ,; I I =1 4 r F �� - I I L_ �L ,-JI- 1"_'i�L1 `�I '1�'I� LV 1" �'LV �J L" L J� JIL1 I L 1__ I I; I T 1 - I I I I I I I _ I I I I I I I I FN Oz�Z KAON I I I �11{ ERs x31- -I_ I I s 102A PRODUCE COOLS 103 STORAGE FREEZER 1 }-I- i- 4- 1-1- H -I- j- -i- - -{ -1- � H- -1- i- -I- -1- j- -I -I- f- -} I I- T- - � - i- j -I- T- � -I- T -t -I- i- 7 -I -��G, � 1- f i f -� �Y -I_ � -I_ i_ �I � 'BA N1 RSI I-_ +-1-}-+-I- { -I-� -{- +-I-}-+-1-I- �_ { --I - Iii= -H+-I-{-� _�-1-4 _4 I _I_L I I I_I ��� Fi 1 �'1 � �'�> I I I __FT_ L1 I _+ 2 1__L.1_1_L1_I_ I _I _ I + _ +_ _I _+ 1-1_L1-1_E1J_L1-1-L1-I-L1 I I I + _I _ +_ _I _+ _ + I _J! I + 1 1 1 + �,6,i , -i- 1- I I I I I I I I I I I I I I I I I I I I I I I I I _L1-I-L1-I_LZ-I_L1_I_�1-I-L� I I I I I I I l 1 1 1 1 1 I� ; ,1 �-1-� -If I ; I% 11 i L I I ; M NOTld I I I I I I I I I I -♦-4-1-+ � -1-F -I-� I I �-I-i-4-1-{-�-I-+--F-1-� 1 H -F_ -I-� H-I-r-�-I-�-=���i- 1 ,f I Y I I �•�, ��T� MEAT/SEAFOOD COOLER T_ T I I I I I I_ L I ISI �I_L�=_L -1- _L _t _I L _I_ L _I_ L L=1=1_L=I_LJ.LJ.=1_ -I- -I- _T - -1- L _I_ L _I_ L J.=1_L -1- -1-1- _I_ L =I_LA=__LJ.=1_- -1= -1- L _I_ -t I �_L -1-1- I I I I I I ��;'� ( I I I I %'' I I I I I I I _I_I I_I 1 L1_I_ �9`1�_I_ I I I I) I I- I�LT= T= T T- 7 T F` T T -I- -i -- 7 -f -I- -i T - EtJDdAFj RIGS I I I I I I I I I I J_ I I F I I w 1 1 1 I T- I _I_L1__L1_1_ __T _r T -T I _T I T I T_T--T-T-I- 1 _L-I_L1-_L1_I_ -T -I-T 1_I_L _I_L1__L1_I_ T T I 1 _L _I_L1__L I 516NAGEI I I I I I I 11 1 1 1 I_L _I_L 4 � 4-1- 4-1_ I I TRAY COOLER 11 I �� I 104E + I `= I I I I I I I I I I I I I I I I I I I I I I I I I I I I j 1 (1TY 1 .12�J 1 1 1 1 1 1 I I I I I I I 1 I I T L I I I I I I I 4 -T--I -��-1- – I I I I I I I I -I=+-+J=�-f -I_�� —I -I I I I 1 1 1 -I=1--I--- +--� -I -I 1 1 1 -i- 1 -1= - -I I I I 1 --I=I-��=T--{ J-� -I 1 1 i 17 1 1 1 1 1 1 1 I I I_ I 1 1 1 -I-f- LJ L ---fit T L_ _T I 1 1 7FT-,=rTl= T- �=f7=F I I_ I I I I I I _ 7=1=rT 1=FT7=rT7=r77=rT -i=j�1->=��=1=�-1=�� I _ 1 11 1-�fi-1=1=��=>_��=��=1=T= 1 =1=fi-1=-= 1 1 _j_ 1 I =1=1==F 1 -t 11 1 I I I->- -I I I "I/� `T L.- 1 1 2 I, I I T T T T T ,, NMEAT/SEAFOOD PREP.1 I I+ - 1_1_L1_I_L1_1_L1 I+ I 1 1+ 1 I+ I I I+ I I I+ _ 1_I-L1-1_L1_I-L1_I_L1-1-L1 I I I+ I I I+ I I I+ I_L1-I_L1-1-L1_I_ I 1 1+ 1 1+ 1_I_L1_I-L_+-1-L I �� + H _1_+.4. EAFOOD' ALES II r� �i� 1 1 1 1 4 1 1 1 1 1 -1 -if+= F�=1= 1 I I l l i l l 1 _-T 4�=i=�-I=�'�=T=�7=1=F4�=F�-=F��=I':=1=T=$-! 1 1 1 1 1 l I I I I I I J_ P�=1=�� � -I- IE �'It�' + + UPC T� J_ I IT I r-i=�= I ILI- -I-- T-- H -1- �_�-1==�=i= 4 -1- - I- - T I -1- -�---I- T_ T -I- �_� i -I -1- -1- i- -I-T- -I-T _��-�=i= - I- - -T -I- =1-� I -1- - I- 7 -I -T- -T - _ - L I - 7T 11 I 1 I\ 1 I 1 I I I 1 I I Q T F. )I I I I I I I 41 1 EC 1 1 1 I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 I I I 1 1 1 1 1 1 I I 104C ME T/SEAFOOD FREE R–— ' r 1 _ IG AG 1_1_ 1 —L _I_L1__L1_I_ 1_I_L _I—L1__L1_I_ I I 1_I_L _I_ I I I I I I I I I I r I I I i i i i i I I _ LJ -i- t- LL _I I I I I I ��a rI- 1-+-1- _-I _ � = 1 1 I 1 1 1 1 1 1 +-I- -i-h + -r +-i- _ = I I I I I I I +-I-F -T-i- - - I I -F �- - = 1 +-i-F -1-t-+ �-i= -� t _ _� I I I \ o I I I I I I 1 I I I I I I I I I I 1 - - I _ - 7 _ - - fi Vii= L _ - 3.� T X I HJT JG T �; I� I I ILI_ L_L 11 1 1 1 1 1J- J_L1�_L1L_JL1J_L I 1 I I 1 1 1 1 1 1 1 J_L1 1 1 1 1 1 1 1 1 _L1J_�1J_L 1 1 1 1 �_L1�_i I I I I I 11 1 - I I I II I I I H C OUTS) I I I I I I IC JANITOR - r �' 101 I LL 1 I -1 -T -1 -1 -T -1 -r -f -T -7 -I -T- T-1-T-7-I-r7-1-T- I -I-T-T-I-T--T-1-r7-I-F-T-- I 1 I 7-I-�7-I-T I _I I-1 I I l T P. V' s I }{ I I I+ I I+ I I I+ I I+ I I I+ I I I+ 1-1_L1_I_L1-I_ I I I+ I I I+ I I I+ I_L1_I_ I I I+ I I+ 1_I i l l+ I I I I I I I I I I 1 Ftp ■ _ _ 3.� T- I L _L.1 -_L1-1- 1__ 1_I_L -I-L1 -L __1J_ H._I_L _I -T-4 -}--1- 4 1 104D TEAT ---- L 11`' I �I- I 11 I AL=L 1== �=�� =1=1�= ��=1= �=�= _L= 1�=i= �_ -I-+- -- =L 1 1 I I I I I 11 I I I I I Ali .� I I I I I -I- -1-t-1 1(00 VESTIBULIE r� I ; r--� -� T 1 I I +- -1- -I-_ i --I J= 4-I-i-1-T--F--�-+ -I- I -I- -I-I I -I I -I- H -I- F- -I=T-+- I -I - I I I _LH -1- I I -I 1 +--_T--i I I I F_ I 1 }--1-t 1 I I I I 1 1 1 1 4 s L_ _m _ J� I I 1 I I I I I A}�GI�IG I B N RSI I AISLE t'hA I2S I I 1 I I I _I- T --T I -T -I- I I I 1 '( I I 17 I I I + 1t�_ ` _� 1 ; I �;, I �- I 1 1 1 I I I I I I I I I I I I 1 1 1 I I I I I I I I 11-T I I I 1 1 1 1 1 1 1— 3.1 I- i s I T- I _I� L1�- 1J -L J_L1 -L1J_ __ _L 1J_L J -L1 _L1J_ Lam_ 1J -L �_L1 _L1 _I_L_I-T- { I - I 108 ELECTRICAL RO 1 I L I t ��a LI r F I _I t+ 1 1 1 11 1 I I I I I I 1 1 1 1 1 1 =F I I I I I I i o I I I 1 1 1 I I I I I 1 \ I -1-T-�- -7-I- �g- I I ; + I 1 i- -I +=-��-1= 7=1= -7=FT-=1=-T=1= -T=1=T= �_♦_� -T- �=1=T=$-1-T=om=1= -T i T F I I 1 a---4-1--1-- T I a-- L- F -�_ F` 7__ Ir _I_ I �_ I I I I I I I T--I-T-T--1-_f-I- 1 I I I I I I -T-1-T--I-T-1--T_-T-I- I I I +_I_ I 1 I_ I I .-T -� - 1--f--fi7-1- I I I I I I _ 1 _I_ _I _ -1- F`, 1 I r� I CUSTOMER SERVICE 118 s 1 I I ,OUNCE , I I I I ---�--�-I I I 109 I I 1- � I L I I I_ I_ I _I _ IT�1 L 1 � = --1 + L L LI _I_ I _I_ I+ _1 _I = _I =L L _ __L 1 _1 =L -f-1 -1=T-1=T-T-=T--T=�- I I _I_ _I_ I 1 _I =L T_I =L -L ---T__7 I I __ =L 1 _I - I I _I_ _ _I -L I _ 1 � 1 1 1 1 _ L 1 _I _ I 1 _I _ L � _I H _ 0 -I _ L _I I OFF ICE IIBA 1 i --i 1 I I I I I i La`s I 1 r'1=T ( PI)LI- I - T_ -j- H -t - Trt-1 rt-I-� I- T_ rt- I- -1- i - I- + - I H -i - I__ff T_-I-rt-I_T H -t - I - - I - I- -I- T- rt- -1- + - T 7-F= I I J Trt-I- -1 I I - I - I- + I I I I I - I +- I - I I I I I I I I I I I I I I I I I i - t- +I - � _1 TT -1- OFFICE STORAGE ROO' 1188 I I f F -�-I I I I + Ir I LI 1 1 11 I I I I I I I I I Tom- f -I=T -1=Tf] _-_i_J- _-�T I I I I I Tf=1= -T_3_- �_IILS -_I_- 1 IT, _J _L I I I I I _ - Y I -_ - a, r L I =1fT�- -t I I I I I F-1 I I I I I I I I I I I I l l t l l l I I l l _L I t l X71- I jyE111G 516NAGE I I I DEL IBAKERY COOLEF IIIB o L 1 I I I 1 !- 4 T 1 = I + - }- + -I Cts I 1 1 1 + I I I I I I I I I- -i - I- -1- I I I 1 1 1 - I- + -I - I I I I + - f- I- + -1 I I 1 1 1 I I I -1- - I I I I _ �- -i - I - I I I I 1 X 1 1 1 I II I I _-= I pAIRY COOLER Ill i-- L� I tI I I I I I I I -T - -7-1 I I I I I I I I T` -T -T` -TTT- TT -T I I I I I I T --TT 7T7 I I I I TT -_T T -7T T 1 1 -r T �f� I+ Ir -9 _ � -� I T I I 1LTL- _ I I I I I - � =1 � � =1 _ I I I I I I I I I = �_ I I I I I I =1�- I I I = �_ �� L I I I I I I I� it / •:, I L'� Y L I I I' T- - 1 ----2----�-: I I I I I I I Irn- I I I I I I - - -- T-1�-T 1 11 1 �-1= -I- T- -i - I ► I I Cry I I I - - - - -1-�-t--t=,T- �1- T -- I I I - 14 WjIJE' I () I TTR 1 11 1 - - - ��-I- �=1-� I I I I I I 1 1 - - -1=��-�1=�1=-IST I I I 1 1 1 1 1 1 1 1 s III 1 1 1 1 1 -1- 1- 5 I I I` I I; II; 11'y I I 1 i W= 1 1 I III%l iI JI t- - I 1� I J I 1 IJ I I I -' 1 1 t o DELI/15AKERY PREP. IIIA I 1 T+ L I = 1_I L F -1-L 1 1 1 T _T -I I I I 1 1 1 =1-L __ I L1-1_ 1-1L C T 71-1- T -T�T� 1-1-1- _r I I I 1 1 11 11 1 1 1 I L L_I_ J_I L rT_I_ t- I- 11 1 I I I-L1-�L IIII 1J II I S L IIII 1 1 1 _1_L I 1 �1 I I- ISI I I I D 11 1 I I„i I II, ,I l��u DELIBAKERY SALES I I I T I I -I - -I - T-1- I I_1 - T- -I -I - T t II I I 1 I F -1 I I I I I I I I I I I I I I I _T-_�--_ II I r j I I I _1 _I_I __I II T -T Ij T I 1- I T T I I I 1 1 1 I I T -T I I I I 1 T I - *IE I� I I(IY I I 3 I I �T i I�„i II 1 �- L.J I �_�_,I_� -4 1- - _ PtAi�L-I- I I I I I L1 -I L -I_ }144 I I "F1�E I I I I I I I l TY (qp� 1_I_L LDAIRY"I I I I 5 V I I I I I __LL I I I I I I L1 -I_ I _I_L I I I T I I I I I I I I _I_L1 I I I I 1 I 11T � =I tt—= � 1= �� =t= i= 1= _ #T=t i= ce=1--i= =1- - =1- - =t --I --r �= - �-=r - - - I- i i I I I I I I ( I I I I I I I - �— I I I I 1 1 1 I I 1 1 1 II I I I I III I I I I I 11 I I I I I 11 I I I III III l I 1-1 C�` I I' >1 1`J `----- l 105A CORRIDOR i'2 IIID DELI 1 AKERY CLOSET -J I I (FOAM MOULDING AT CII _ A 1ALL I ERIMETERS) 11IG DELIBAKERY FREEXER OG F_5 FA O O Ur- I B� A.1 rql TRUE NORTH 1!) PLAN NORTH NOT USED SCALE N.S. I. AISLE MARKERS TO BE LOCATED BETWEEN EXISTING FLUORESCENT LIGHT FIXTURE. TYPICAL FOR ALL AISLE MARKERS. COORDINATE FINAL LOCATION WITH KASH N' KARRY. 2. CASH REGISTER FIXTURE LIGHT TO BE HUNG 9'-0" A_F_F_ ABOVE REGISTERS. COORDINATED WITH ELECTRICAL DW'GS. 3. CHECK-OUT MARKERS TO BE LOCATED AT CASH REGISTERS. COORDINATE FINAL LOCATION WITH CASH REGISTER MANUFACTURE AND KASH N' KARRY. 4. LINE INDICATES EXTENSION OF AXIOM EDGE. REFER TO ENLARGED REFLECTED CEILING PLAN ON SHEET A-9. 5. ILLUMINATED DEPARTMENTAL SIGNAGE. COORDINATE W/ ELECTRICAL DWG S. 6. ALIGNED SIGNAGE UNDER THE RECESSED LIGHT. REFERENCE NOTES (D 1. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR CENTERLINE OF COLUMN UNLESS OTHERWISE NOTED. 2. THESE DRAWINGS SHALL 5E READ IN CONJUNCTION WITH STRUCTURAL, MECHANICAL, ELECTRICAL AND PLUMBING AND SIGNAGE AND DECOR DESIGN PACKAGE. 3. DASHED LINES INDICATE EQUIPMENT/FIXTURES BELOW AND ACT_ CEILING/LIGHT FIXTURE ABOVE. 4. FINAL ELEVATIONS, CONSTRUCTION DETAILS AND SPECIFICATIONS OF GRAPHICS AND SIGNAGE ARE TO BE COORDINATED WITH THE SIGNAGE AND DECOR DESIGN PACKAGE. SIGNAGE PLAN 3 32LE1' 1 SCAGENERAL NOTES 2 AUH11tulut 111) I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281,9299 Fax 813.281.9292 E—Mail ap'@arch'tectureplus.com License #AAC001935 I' Dash n' Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- _________________________________________________ ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL --- #AA001935-------- NC_ #50985 ---------- GA #8343 SC #98033 ----- ----------------------------------------------- TO T}f BEST OF 11-E WM-EDGE OF TFE AflD4TWFS AND HVGt4EH� SAO RlNS AAD 5TJUICATONIS LOWLY WITH THE ARPJCAaE NWW.0 BI.IQNG CODES AND TFE AFPUCAE E MNMW FIFE SAFETY STAhDAFDS. KASH N' KARRY NO. 1890 SANFORD,-- FL ------------------------- PROJECT NAME SIGNAGE --PLAN - _ _ _ _ _ _ _ _ _ ----------------------------------------------------- SHEET NAME PROJECT NUMBER: 9949A1 - ---------------------------------------------------- DRAWN BY: DR CHECKED BY: API ----------------------------------------------------- SCALE:AS NOTED ----------------------------------------------------- ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE Fat BID/PERMIT ----------------------------------------------------- ------------------------------------------ SHEET NUMBER EL = 30'-0" A.F.F. ----------------------------------------------------- ------------------------------------------------- Z� ----------------------------------------------------- T.O. NEW PARAPET/CORNICE REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL#AA001935 NC #50985 ------ GA ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------- #8343 SC #98033 V" ----------------------------------------------------- To TFE BEST OF THE 00hI®GE OF TFE PACHTECTS MD EN13NEEFA SAD RMS AND SPECFICAUM COWRY WfTH THE AFflJCABLE MNMIM BLALM CCCF.9 AND THE A-KCABLE MNNW FFE SAFETY STA DPFDS • - DOOR FRAME - HOLLOW METAL FRAME BEYOND • ' •' VCT BEYOND - HOLLOW METAL = METAL DOOR DOOR EXTRUDED ALUM. SEALED CONCRETE DOOR SWEEP 3-5/8" w 4' O.C. HORIZ. W/ (3) 1*12 TRANSITION STRIP TO TL (PEMKO 321AN) CONT. L6x6x5/16" W/ 1/4" TEK EA. END BE FURNISHED BY DREADNOUGHT. EDGING STRIP ALUM. THRESHOLD STIFFENER V 10'-10" O.C. MAX., COORDINATE LOCATION W/ 5/8" FRT CpX PLYWOOD FASTENED DREADNOUGHT QUARRY TILE IMUp SET) (PEMKO IIIA) * .4I -I- �iCPOSD STS._ EXISTING JOISTS TO STUDS W/012 SELF DRILLING FLAT CARPET TILE. Z/F/ HEAD SCREWS m 6" O.C. EDGES, 12" TO 3 HOT DIPi= D . (l) 3/4" DIA. BOLT O.C. IN THE FIELD "•. '• �• • THROUGH CA325 4. !^' BOLT) ' 1��r I yI 1}..•1��.,+ ii �/ II �✓� OI\ DBL_ FRT PT 2x8 BLOCKING m 32" O_G. . •.. `,. •i `:.' ., LAG '. AT MAX.;;; ,. .. SIT I\ M _ �, _ EL - 2 -0- AFF. o W/C4) 16d NAILS EA. END, EA. BLOCK .a, .. g11 C.C. C HEIGHT OF NEW BRACING 5/8" DIA. BOLT THROUGH Q 32" O.C. T6 T5 T4 TS 5x5x1/445' all 18 GA. Iroll O.G. 8" 20 GA_ 6 16" O.G. - DOOR FRAME - DOOR FRAME TS 5x5x1/4 EVERY OTHER - EXISTING: HOLLOW METAL BEYOND BEYOND JOIST (10'-10"O.C.) FRAME BEYOND = DOOR DOOR - HOLLOW MTL. DOOR (EXST) VINYL TILE SEALED CONC. 1/4 GUSSET PL, CUT AS REQUIRED 1/8 I x2 FLAT MTL. II 1 %THK x 2 W. SLOT THRU TS - 45' CERAMIC TILE EDGING STRIP FLAT METAL BRACE 4" PIPE COL. lm' -10" O.C. Q QUARRY TILE EDGING STRIP o MARBLE THRESHOLD. (MUD SET) VCT L6x6x3/8 (1) 3/4" DIA. BOLT ADD L3x3x1/4 "X" BRACING BETWEEN JOISTS DIRECTLY VCT ', THROUGH (A325 BOLT) UNDER 4" PIPE COLUMN i : '' : :: •' :; 4" STD. PIPE COL. 16" LONGS LOCATE ON JOIST •'. :; , ".;; �:F :, • ::.. LAG : AT MAX_ <. ��. LAG AT MAX. PANEL POINT 3/16" < C O.G. 9 O-C- 6x6x1/2 BASE PL T3 T2 T1 EXISTING JOISTS 5'-5" O.C. C F.) TYPES SCALE SCALE 4 V.I 3" = 1'-0" EXISTING 22K JOIST 6 5'-5" O.G. SECTION THROJ49H J0I6Te PNGSPACE DOOR CAS APPLICABLE) FRAME (11) DETAIL REFERENCE FINISH REMARKS OPNG (Y.LF.) TYPE WIDTH HGT. THK. MAT'L HDW. TYPE MAT'L HEAD JAMB TILS DR. FRM. NO' LOC- NO. HIGH PARAPET BRACING DETAIL SCALE 5 I — , _a I 102/101 C (01-011 ,_ I, l 0 3/ 4 S.S. ALUM MFR. EXISTING EXISTING N/A N/A TI - PAINT 1 2 104A/I01 A 3'-6" -1'-m" 3i4 S•S• ALUM MFR. EXISTING EXISTING N/A N/A T2 _ PAINT (0/-1 2 OIL EL =MATCH W/T.O. ADJ. CMU WALLS 3 110/105A G 6'-0" -t'-0" 3/4 S.S. ALUM MFR ST -I STEEL H-2 J-2 T1 - PAINT 3 4 114/1.05A EXISTING - - - - - - T1 CLEAR PAINT 3/9 4 FRAME THROAT i CHANNEL THROAT CLR TO T4 3/�/II ACCOMODATE STUDS AND GWB CLR VARIES 5 105,4/EXIT EXISTING - - - - - - PAINT PAINT 5 6 115/105A EXISTING - - - - - - T3 PAINT PAINT 3/1/11 6 - EXISTING CMU WALL _ _ _ T3 3/-1/II - _1 116/105A EXISTING - - - - - - PAINT PAINT 8 105A/101 REMOVE - - - - - - N/A - PAINT 1/_T S 5/5" GWB 9 101/111 D " 3'-0 4'-0" N/A ALUM MFR. N/A - N/A N/A T2 N/A - 2 9 5/8., GWB EL = AS IND IGATED 10 — 101/117 p 3'-0" 4'-0" N/A ALUM MFR. N/A - N/A N/A T2 N/A - 2 lm 2 X 'FR' WOOD BLOCKING AS REQUIRED ACT AS SCHEDULED 2 " X 'FR' WOOD BLOCKING 11 118/118A B 3'-0" 4'-0" - - - - - - N/A L. LAM. - 2 11 (ATTACHED TO CMU WALL)- AS REQUIRED - = BED SEALANT BOTH SIDES BED OF SEALANT 50TH SIDES STEEL CHANNEL AS REQUIRED WALL FINISH. REF t0 FINISH SGHED. 12 11814/1105 EXISTING-� - - - - - - PAINT PAINT 12 13 1148 E 3'-0" 1'-0" 3/4" S.S. MFR. 6T1 STEEL H -I J-1 T1 N/A N/A - 13 STEEL CHANNEL AS REQUIRED 1X WOOD BLOCKING AS REQUIRED IX WOOD BLOCKING AS REQUIRED ALUM - - - N/A 3/8/I0 14 106/EXIT EXISTING - - - - - - PAINT PAINT 14 FLATHEAD SELF -TAPING SCREWS 15 102/EXIT EXISTING - - - - - - - - 3/10/12 15 (COUNTER -SINK) FILL PUTTY - SCREW HEADS BEFIORE PAINTING FLATHEAD SELF -TAPING SCREWS FILL PUTTY (CREW 16 101/EXIT EXISTIN�� - - - _ _ _ - - - _ _ 3/10/12 16 SCREW NBEFORE PAINTING HERDS EADS OPNG SPACE WINDOW (AS APPLICABLE) FRAME DETAIL REFERENCE FINISH REMARKS OPNG DOOR AS SPECIFIED DOOR AS SPECIFIED J2 H2 NO. LOC- TYPE WIDTH HGT. THK. GLAZE HDW. TYPE MAT'L HEAD JAMB WINDJ IL WIND. FRM. NO. A 105A/105 AL -1 51 -Oil 41-011 5/8" TEMP' GLASS MFR AL -1 ALUM. DTL 2/A-6 DTL 2/A-6 DTL 21A -(o - _ 4/5 A VARIES VARIES 1. REMOVE TRANSOM BAR, GLAZING STOPS d GLAZING ± PATCH, FILL AND PAINT. 2. F-LIA50N LWP-5 OR EQUAL BY CHASE_PURUS. REFER TO PARTITION TYPES REFER TO PARTITION TYPES 3. EXISTING DOOR TO REMAIN. FOR METAL STUD SIZE FOR METAL STUD SIZE 4. CUSTOM SLIDING GLASS DOOR. MFR PGT. SERIES 2000. 5. REFER TO SECTION 3/A-6_ 6_ PROVIDE FULL PERIMETER GASKETING. 7_ FRAME TO BE REPAINTED. REFER TO INTERIOR COLOR SELECTION ON SHEIET A--1_ GYPSUM WALLBOARD U.O.N. '/z" GYPSUM WALLBOARD U.O.N. r^ VJ 8. THE GENERAL CONTRACTOR SHALL SAND, CLEAN REPAINT ALL EXISTING HOLLOW META!_ DOORS SCHEDULED FOR REUSE. THE DOOR HARDWARE, WEATHER-STRIPPINCx, ETC. SHALL BE BROUGHT UP TO DATE WITH CURRENT KN'K STANDARDS. COORDINATE WITH KASH N' KARRT- CONSTRUCTION REPRESENTATIVE. METAL STUD FRAMING M 9. POOR *4 SHALL HAVE PUSH/PULL PLATE 4 DEAD BOLT. METAL STUD FRAMING L.L. 10. THE GENERAL CONTRACTOR SHALL INSTALL ON DOORS #1415,16 THE FOLLOWING: VON DUPRIN EXIST DEVICE PURCHASED FROM BEASOM CONTRACT HARDWARE C1-800-96�- 0394). _ 1/2" 11_ THE RESTROOM SIDE OF DOOR #(o 4 ""l SHALL BE PAINTED SHERWIN WILL -IAMB "PURE WHITE" SW1004. 12. THE GENERAL CONTRACTOR SHALL INSTALL A WIDE ANGLE DOOR SCOPE 4 PAINT STORE NO. ON DOOR 016 USING A 4" STENCIL, AT CONTRASTING COLOR FOR VISIBILITY. w - HOLLOW METAL FRAMEEL. _ HOLLOW METAL FRAME AS INDICATED DOOR PANEL 0 TYPE O DESCRIPTION Z DOOR PANEL N A 5/8" TEMPERED CLEAR GLASS LINE OF FRAME BEYOND B POLY CARBONATE GLAZING. J1 H1 HEAD/JAMB DETAILS 3 DOOR/FRAME/WINDOW SCHEDULE N/AALE 3CAL=l'-O AS INDICATED 2111 AS INDICATED 8 _0 ALUMINUM 211 AS INDICATED L L N p AQ HALF GLASS Q ALUM. CLAD - AS INDICATED ALUM. CLAD p GLAZING � GLAZING () cD Q Q vvvvv ��vvv 6TAINLE55 ��vv ��v�v D vv�vv Z - INLE55 STEEL Z HOLLOW METAL •�v��v ``�`��• Z ATEEL GLAD ��v v��,� _ ALUMINUM y � vvv �vv v� v\11 - O _�vxxX v�vv CLAD v���� 6i � �, v vvv SINGLE DECK SEAFOOD CASE to v vvv \11 IX,vv N' Q vvvvvv TEAR DROP / Q � TEAR DROP M BUMPER5 BUMPERS { r DOOR FRAME� _ ST1 pCAFE DOOR C WOOD F� � O AL 1 MEAT/SEAFOOD PREP. STEC- CHANNEL ATDELI/BAKERY DOOR AND FRAME TYPES SCALE i ARCHITICTURI 1V I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813,281.9292 E—Mail api@architectureplus,com License #AAC001935 P, Dash n Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ------------------------------------------------- Z� ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL#AA001935 NC #50985 ------ GA ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------- #8343 SC #98033 V" ----------------------------------------------------- To TFE BEST OF THE 00hI®GE OF TFE PACHTECTS MD EN13NEEFA SAD RMS AND SPECFICAUM COWRY WfTH THE AFflJCABLE MNMIM BLALM CCCF.9 AND THE A-KCABLE MNNW FFE SAFETY STA DPFDS KASH N' KARRY NO. 1890 SANFORD,-- FL ------------------------- PROJECT NAME DOOR __SCHEDULE ________________ &__ DETAILS ------------------------------ SHEET NAME PROJECT NUMBER: 9949141 DRAWN BY: DR/CE CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ISSUE F0Ft BID/PERMIT --------------- A�__1_0 ----------------- SHEET NUMBER No. SPACE / ROOM FLOOR BASE 14ORTH SOUTH EAST WEST CELING HEIGHT o. MATERIAL LAS FH MATERIAL FLASH MATERIAL FNM MATERIAL FNSH 100 VESTIBULE CPT/VCT VB CMU1GWB PAINT t MARL ITE GWB PAINT 4 MARLI7E GLA55/GWB PAINT 4 MARLITE GLASS/GWB PAINT t MARLITE EXOT.GWB 9' -II" 1/2/4/10 100 GLASS 5.5. FNT. 101 GENERAL SALES VCT V5 CMU/GWB PAINT t MARLITE CMU/GWS PAINT 4 MARLITE CMU/GWB PAINT CMU/GW5 PAINtt MARLITE EXIOTGLG. 12'-0" 1/2/4/10 101 5.5. FLAT 102 PRODUCE PREP ..................... ........ 102 - .... - .............. 102A PRODUCE COOLER --- ------------- •-------------....----..... 102A . .._........ ------- •---...... ---•-••--- 03 O E FREEZER.............•--......_.....__.......__......------......---...............----......----....----.....---....---......---....---........----.....---.. ...-----....----•• •••-----•.•-•---...'.'.'.'.'.-•-•---•••.•---•-- 103 . GT -1 GT -1 104 MEAT/SEAFOOD SALES VCT VB N/A N/A CMU/GWB CT/GLA55 N/A N/A N/A N/A EXIST. CL.U. 8'-10"1/2/& 104 DAL WHITE -D-100 41IX4" DAL WHITE -D-100 411X4" CERAMIC WALL TILE: FNT• CERAMIC TILE ABOVE TO . c0 c\\n-_IfI-E_-EII -_]F II .- - -III�I-\I`III.I11- ___-_- II II11 -- 1/ ___- \M1:-.IJ-5AL-_IHf:.I1-_11).:q/II,1G.I1�-': I __-_- I1_-_:.,6 _N_,, : I_ -_.I1, --I- A\,,.I1I_I-1111---t.'111�1I�I1'1�,1?1"T< 1T r1-II11­I11R''%11> ."111'II1 II --,,/ 1- 1I1I �--R_::-- ��iI s. ,1I_-__ --,_ 1 -- I L 1. I_-___---I\/i.II-_-_+, + I ,M_ -_l -. IIIII 4 4, :� , I -N-�-/ ,�-.. �I-- ' I _- ' I ----&-_41T1II�14I w.'1-_-011,_.'1�1_1I I-_1 1-_1�1-'­1G1�1,I`,-_-,.,. jI/I =---EV1��-_-/�,_-;1I.1II r-_1-=--- --1--_---.- 10; ) II I1 -- >-<I,�7\iw-,ACTo-P_-I-�,_�+-:1-_I_]HI_ __-+1UrIIIIIII.___:+-�tIII1LFrII--- -.I- I IEfIIlI I -_--tI III, I _I tIIII�,II,//I-//1tIIII "II I I 1 -_t- . II�II�II,II III I �Dt I ---- -: IIIIxIII�_--_--=.---/// II--_ -I, CERAMIC TILE ABOVE >TO 104A MEAT/SEAFOOD PREP. X15TING QT. EXISTING Q . CMU/GWS FRP/GLASS N/A N/A N/A N/A N/A N/A ExISTP'REFAe 10'-0" N/A 104A CEILING CEILING 1045 MEAT/SEAFOOD COOLER ---_-_"_-. ".-.'_' .-. ... "...................... . . . ........ . .. .. . ..........."."."."..- .-.'..•_•_ .-_-_-__._.. __.-__._._.. __.. - - - I111111IIIII ------:--_- 1II ------_- I ----_-_-/ ,1I ---, I I, ---1aIIII[=_K�III1l, _IIIlI L -_-.,1I I -I 1I.II1 1I I --IW1I --I1--=1IIIIIIII -Ii1�� IIi1 II.LI I#__--1d1I1II1.1I111<"- 1i__-I-1I1I.iIIIII II -_IIII I.F----I_4--� LIIII � - T 4I_III_-4-9._-_T,_. � I1I--T-4_zT"I--"-+_CI -- -11--j-:_1f. O1,-4�. .H -W- >`-IA.,N _-I---�1__ /-=-�I- �._---- _____ FI=__',1 I__T - III _-��]II _-�_.---I,1I-.---�N--��0-�- II1I �-11IIII1 <� II 1I_#\[I11I7_1I1-j'"�IV-1I.�'1I1I�4111L,I11 "11II11II ;:xII1I11�4:I1F< 4I. __ --f > IIIIII:11II4; II1III1;---_ ) _�III j�-< :_--1-Z_-1II i.I :_f -I1 w-- IIIa1IIIII I1=_FI111-I11 IiIFTII119 III I11 IIIIII 1III II IIM IIIIIII II1II II1. M9.I III_If/jII1III1I 1 III[11I- < 11 111 11 1/--- YI1 11I1_:�1I11 1�11II1III1IIIII'fIIII ir f-,IIIII,<- II "=1­I-II1II 1111r>-x_0-I'III II1_---I]11 1___IL1 1 -. 1 I.1 -6 .1 -\ 1 � _4 -II �I - 1 =-"JQ%=1T�1 TO M......yw ...-. .. w...M- w.....M..._....m....-. ..._*.-. < .._-...__.-. ...-...*..w..m...,,..w ....,.--W....7_........ ..M..<....w-... .-...........,-_..*......_..._.w-....-"......�-.......1.._..M..._....-"..0..........(..>-._._... _"_M.... _...._M..�...-.�....._-M_\ M. -... ....... ...I *-.t..._....-,:...............*-...._...-,r.........�'.... M..".--.�i� w... - / ._... ......._..... .. m. - ,....w....T.M-.w. EL=5'-0" AFF CT -1 DALTILE 0-100 ---------------------• ..................w. ........ .- ._ .. ._ _._. --- -- . - ..... ... . 1048 \ EL=S 0 AFF WHITE (4" X 41) M S ---..... ... ......--- / ❑ 104G EAT/ EAFOOD FREEXE CT -2 CT -2 ............. _ _. - _-_•.•.•.-_-_--. .- _-_•.-."---•••• . ..----.._....._ ...---------•- ..---- ---- -- --- 104c 104 ....... .....--------------------•---......------•---.......... .....---------•--••••-------•--- •• ... . - ----- D MEAT STORAGE ---..... ........ ................ .... - •--------...._--_ ....w... ........ ............---- -- • _" " . 104D GT -3 HCT-2 DALTILE 0-131 .......... ................................................................................................................................................................................................. CT -3 CANVAS C 4"X4") 104E TRAY COOLER .. . .......................... . . . .......... . _ .. .. - - - _ ....... . GT- 5 ."........ ...............--....----- •-----.......... - .... 104E CT -4 ............ --------•--•-----..... 105 co o ...CT -3D - RRID »1 ---.......w.......... ....... ........ ...•••...w..... -- -..... ALTILE O 11l R. ssIj;;•-• .... ...... ....... . .... ............. - ... ...__..._.. ...-----•------ ---•- ......-- ...... :: „y,;, BLUE MOON (4"X4") -• • "- 105 D ITE IPE. 4X4 DAL WHITE -D-100 4"X4" 105A CORRIDOR w1 VCT 1/B CMU PAINT t MARLITE CMU/PREFAB PAINT < MARLITE CMU PAINT t MARLITE CMU/GWB PAINT < MARLITE ACT -3 8'-0" 4/10 105A CERAMIC ACCENT TILE CONT. CERAMIC ACCENT TILE CONT. BELOWSTRIPE. BELOW STRIPE. ............................................................... --.....•----_.....-----..... .-----........-------•-- CT-4 DALTILE D H - 51 106 REGI=fVING .......--•................................................................... 106 GRAPE (4 X4) . --------•---•••-------------------------------------••-----..........------....... ............. -------------------------------------- - ..... . .-----....--. ------------------------------------------------------------------------------------------------------------------------------------------ ------------------------- . . . " _ ... ........... • . •-• • . .....-_-_-_•.•.'.•- ".'.'::::. 101 DET . . • - . ........................ . - .. - -- .--.............•---. --...---------....------ . - EN RESTROOM 109 LOUNGE............................................................................. ...........................••------•-••----••------....--•--.......---... .....-----....._.. .........- --...........---•--...--- WOMEN'S RESTROOM ........................ - .............---.....-------------------...------.._...---••---...----- ........-----. 109 ..--•---------------------------------------- . 110 GROCERY STORAGE " " _ _ _ .. .... •• . .- Ilm III DAIRY COOLER ..w_........_. ......... ................................••--• ...._...------.......--------...--- 111 ". - .- -- 112 112 I A ........ ......... ................ .---.......----- ...----...--•--- •-••---------------•-•----•------ ............MMDKERY STOF ACsE .-. .. . .............. ,_....w._......-...-....-- ..... ..._...... _...._.......- ...--...........------ ... ------:: ._..."..---....._. 113 3 ICE CREAM FREEZER - - ..... . . - ................ . - -------------------------------"."."."_ ".'.'.'.'_'_ ":. 114 114 SECURITY ROOM 114 A INTE IEWIN O ._._._.__Mw .'.'. .... ..----.... ------------•- ................ ...............- ---- ... .._----- .........-- RY G R OM- . 114A - 1145 PG7R.41NINGROOM ----------------------------- -------------- VCT VS GW5 PAINT CMU PAINT G11B PAINT GW5 PAINT PL7U/EPDXY V-0" 4 1148 PAINT WHITE 115 MEN'S ROOM CT CT CMU CT CMU CT CMU CT CMU CT GWe/EFOXY 01-0, I,18/15 115 CERAMIC TILE PATTERN @ RESTROOMS SCALE PAINT WHITE N/A 116 WOMEN'S ROOM G7 GT CMU GT CMU GT CMU GT CMU GT Gwe/EFoxY 8,-0„ 7/8/15 Ilb FAINT WHITE 117 DELI/BAKERY SALES ISTING QT. EXISTING al. GWS CT GW15 CT. CMU/GLUE CT GW5 CT AOT -I 8'-6" 5/6 III 1. REFER TO INTERIOR ELEVATIONS AND DETAILS SHEET FOR ACT: ACOUSTICAL CEILING TILE FLOOR COVERINGS PAINTED WALL PATTERN LOCATIONS AND LAYOUTS. CMU 11IA DELI/BAKERY PREP. ISTING Qt. EXISTING Q - CMU/GUM CT t S.S. GWS/FREFAS FRP CMU CT GwI5 CT ACT -I 8l-6 516 IIIA CONCRETE MASONRY UNIT REFER TO FLOORING PLAN FOR FLOOR COVERING FRT 2_ REFER TO SIGNAGE AND DESIGN DECOR PACKAGE AND LEGEND. VINYL COPE BASE: CO __ __.'----------------------------------------•--- --."....-------•-•---•--...-------"-- CPT . CARPET NAF CB -80 II75 DELI/BAKERY COOLER --'_•.' • " - - - - • • . • - - - - .... - - . " ... . . . ............ . . . . • • - ....... . • • . • • . .-•-•-•-••'•• . - .•.•.-..-.-_".'.-:.•.• IIIB G PAN SHEET FOR ALL SIGNAGE, BANNER, . . . ........-- .......................... CT : CERAMIC TILE IIIC DELI/BAKERY FREEZER "•_._•... _ _ " _'_'::.... ---.•_•_•--. .-. "- -•- ..-.-. -_ "..............."-.-.-.-...... _ ..... -•- . -M......11IC S E MARKERS, WALL TRIM, AND NEON SIGN LAYOUT AND PREFINISHED WALL PANELING ................. ................... .. .. --- - -- ... -- ---••-----....-•------...-----•-"""-. .._...------...---............................. ...---------.........---- OCATIONS. FRP: FIBERGLASS REINFORCED M"__ ...- "--. . . ,"-""m-"*",-",,"* '"' __._.... IIID IIID DELI/SAKEi.Y CLOSET ..... . ........ . MARLITE: WOODGRAIN COLLECTION ------------------------------------------------ ----------------------------------------------------------------------------------------•-•------------------------..... ...-------._........----- CWB : CEMENTITIOUS WALL BOARD •----------------- •-------•-."---•--------------••-"----•----"------••-------...._ 3. AREAS WHERE FLOOR DRAINS ARE INSTALLED, """----"�-""""•""""""" """."_"-"""". THE FLOOR SHALL SLOPE 1/16" PER FOOT TO DRAINS. DESIGNER SERIES PLANK 118 CUSTOMER SERVICE VCT VS CMU/GW5 PAINT 4 MARLITE N/A N/A GW5 PAINT t MARLITE N/A N/A AXIOM EDGE 8'-0" 2/4/10 118 C. BTL: GALVANIZED STEEL COLOR: 323-52 "PLANTATION" 118A OFFICE VCT VB GWB PAINT GIUB PAINT GWB PAINT GWB PAINT AXIOM EPG6 8'-0" 4 I18A 4. 4" VINYL COVE BASE. GWB : GYPSUM WALL BOARD FRP: FIBERGLASS REINFORCED POLYESTER, ------------------••-"-----..............------.......------------...----...----...-----••-----------.-.-- 4 .Ilse OFFICE STORAGE ROOM ..... .................. .................... ---------••----......_......... ._.....................---...----....--•-••----....._. . -- 118)3 GO CRETE SANITARY WALL SYSTEM , PEBBLE -...... .._... .... .. 5. 1/2" THICK ABRASIVE QUARRY TILE (6"X6") W - •-. •. --... ...----- --...----- ITN PLWD : PLYWOOD TEXTURED SURFACE. COLOR: WHITE SETT INC 5E°• FINISH SCHEDULE (ROOM FINISH SCHEDULE AS PER PLAN NORTH INDICATED ON CONSTRUCTION REFERENCE PLAN) SCALE PLAT :PAINT TOILET PARTITION'S 4 CERAMIC WALL TILE (HATCH INDICATES NO WORK TO BE DONE ON THIS AREAS) N/A 5 6. QUARRY TILE BULL -NOSE COVE BASE (1/2"X6"X6")_ PREFAB: PREFABRICATED INSULATED REFER TO RESTROOM DETAILS ON TH15 SHEET. 1. CERAMIC TILE (5"X0") WITH THIN SETTING BASE. PANELS WNCT : PLYWOOD WAINSCOT ACOUSTICAL CEILING TYPES NO DESCRIPTION O MANUFACTURER MTG HT REMARKS 8. CERAMIC TILE BULL -NOSE COVE BASE (6"X0") Y5 : VINYL COVE BASE ACT -1: "VINYL ROCK" BY U.S.G. 032-10, WHITE, 1/2" 9. REFER TO RESTROOM DETAILS SHEET FOR WALL PATTERN VCT: VINYL COMPOSITION TILE BOARD W/ VINYL FACE 24" X 46" X 1/2" 1 ELECTRIC HAND DRYER BRADLEY # 25-13 40" A.F.F. ,@ CL. GC PROVIDES 4 INSTALLS. LOCATIONS AND LAYOUTS. aT :QUARRY TILE W/ ALUMINUM T -BAR GRIP, COLOR WHITE. 2 DISPENSER TOILET TISSUE 8-213* BOBRICK 19" AFF '6 C.L. GC PROVIDES 4 INSTALLS. 10. MARLITE WAINSCOT TO 40" AFF. TYPICAL AT ALL 5C: SEALED CONCRETE ACT -2: 24"X48" USG INTERIOR MILLENNIA CLIMAPLUS - LOCATIONS OTHERWISE INDICATED ON ELEVATIONS. 5$ : STAINLESS STEEL FACE CUT ILLUSION TWO/24 OR EQUAL. 3 FEMININE NAPKIN DISPOSAL (DOUBLE) 8-354* 505RIGK 33" A.F.F. TOP OF FIXTURE GG PROVIDES 4 INSTALLS. 11. PAINT CEILING W/(2) COATS (MIN.) SHERWIN WILLIAMS "PURE ACT -3: 24" X 48" AND 24" X 24" ARM5TRONG-RH90 4 FEMININE NAPKIN DISP05AL (SINGLE) 5-254* BOBRfCK 33" AF.F. TOP OF FIXTURE GC PROVIDES 4 INSTALLS. WHITE" EPDXY "SW 1004. CnI/0 FINE FISSURED #1129, USG-AURATONE CORONA 5 MIRROR 20' X 28" 5_Ir05* BOBRICK 40" AFF BTM REFL. SURF. GC PROVIDES 4 INSTALLS. Z 0 90 X990, OR CELOTEX-HYTONE VANTAGE 10 VAN 19-1. GRAB BAR W/PEENED SURFACE 5-6106X36"* 505RICK 36" A.F.F. v BAR C.L. QUANTITY: 1 PER H.C. STALL O Z 6 GC PROVIDES GC INSTALLS. W GRAS BAR W/PEENED SURFACE 5-6100X421* 505RICK 36" APF. m BAR GL. QUANTITY: 1 PER N.C. STALL 0 GC PROVIDES GC INSTALLS. ♦^ vV S TOILET/URINAL PARTITIONS REFER TO 5PECIFICATION6 CONTRACTOR TO SUBMIT MFR STD. COLOR V, w CHOICES TO ARCHITECT FOR SELECTION. cc > J g SOAP DISPENSER 40" AFF MAX. KA5H N' KARRY PROVIDES 4 GG INSTALLS. LU 10 DIAPER CHANGING STATION "KOALA" OR "AMERICAN INFANT CARE" OU Q r ♦♦=^^ (FLIP DN HORz) PRODUCTS. PER MFR. M NT PER MFR INSTALLATION MANUAL 2 00 KOALA CORPORATION 4390 MCMENEMY ROAD, SUITE 5, ST. PAUL, MINNESOTA, 5512-1 AMERICAN INFANT CARE PRODUCTS 9-111 TREE FARM ROAD EDEN PRARIE, MINNESOTA, MLI) En z PHONE - 612/490-1535 "BEAR KARE HORIZ. BABY CHANGING STATION" 55344 PHONE -612,/4-14-0204 "DIAPER DECK" LL Q NOTE: ANY DIFFERENCES 5ETWEEN THE CONSTRUCTION DOCUMENTS AND SPECIFICATIONS THAT CONCERN THE RESTROOM ACCESSORIES, THE DRAWINGS SHALL GOVERN. SCHEDULE NOTES SCALE 4 FIXTURE SCHEDULE-RESTROOMS SCALE N/A N/A BENCH MARK WOMEN'S ROOM 6 10 1 g 11 1 a 2%10 6 2 �<�> 115 MAN'S ROOM 116 �2<I 9'-o" GENERAL NOTES: -i 4 1. ALL OUTSIDE WALL CORNERS SHOULD HAVE RADIU5 / BULL 1 NOSE EDGES (T'I'P. FOR ALL CT. COVERED WALLS.) 10 �j \ 2 2 1 1 2. PROVIDE NEW TILE SUBSTRATE ON NEW STUDS 1/2" 10 6 DUROCK TO 4'-O" AFF 1/2" M.R. GW5 FROM 4'-O" AFF `� \ n 10 10 TO CEILING. FOLLOW TILE COUNCIL OF AMERICA AND f - 10 fi TILE MFR RECOMMENDATIONS TO ADHERE TILE TO ° EXISTING PAINTED MASONRY. 5 0 o S ELEVATION ELEVATION ELEVATION ELEVATION 3. PATTERN TO >3E CONTINUOUS AROUND CORNERS. MEN'S MEN'S O �MENS O 2 2 4. THE CERAMIC WALL TILE AND BASE SHALL BE SANDED 1 S 1 BENCH MARK 6 4 -1 S 3 a -, POLYMER MODIFIED (LATEX) GROUT. 10 g 10 2 q Il 6 9 TYP 3 I _1 2 ( P) E. ALL DIMENSIONS FOR FIXTURES ARE TYP. U.O.N. ALL -4'-6" 6" B - RESTROOM DISPENSERS SMALL 5E 40" A.F.F_ U.O.N. \ 6 Cx Alm.l 2E I -6 -� 2 A AIm.12C &. GENERAL CONTRACTOR SUPPLY 4 INSTALL INSULATE HOT 11 Ia 0_ / WATER DRAIN PIPE INSULATION ON ALL RESTROOM \ 0 5 LAVATORIES. o f 1 5 C3 0 N, 1. TOILET FIXTURES ARE EXISTING AND WILL i3E REMOVED ANF /_;t `t v Q _! 2 Q REINSTALLED AS 15. mz ry I]$1I� om o� ELEVATION �ELEVATION ELEVATION ELEVATION g 1 WOMEN'S WOMEN'S WOMEN'S ® '�` I'-41/2" - ,'-4 I/2" WOMENS INTERIOR ELEVATIONS- RESTROOMS SCALE 2 ENLARGED PLAN-RESTROOMS SCALE -- -- --- - - -- --- ARCHITICTURI [U5 I N T E R N A TI O N A L 70 2 9 Rocky Point Drive, e2 Suit 201 Tampa, Florida 33607 Tel 813,281.9299 Fax 813,281,9292 E -Mail ap i@architecturep lus.com License #AAC001935 i I,lash n I Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Z� ----------------------------------------------------- zn� ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL_ FL_ - - - ---------------------------------- -#AA001935NC #50985 GA #8343 - . - SC #98033 - - 4 � --- ------------------------------------------------- TO THE BEST CF TFE IVJMMGE CF THE AMITECTS AND Ef",EEAS SAD R -AM AM 131`13CFlCATONS COMPLY NRH TFE APPI-CABLE MNMJM BJ -DNC CCD.S AM TFE APRJCABI_E MNMJM Rf� SAFETY STArDAFDE'i. KASH - - N'--KARRY-- NO. --1890 SANFORD,- FL ------------------------- PROJECT NAME FINISH --SCHEDULE--& ----------- PLANS --------------------- PROJECT- ---------------- PROJECT NUMBER: 9949.01 DRAWN BY: DR CHECKED BY: API SCALE AS NOTED ----------------- - - ------------------------------- ISSUE DATE: 9/06/01 ISSUE FOR: BID/PERMIT - --------------------------------------------------- ------------- A710-01 -------------- SHEET NUMBER I i I y I M I I >p �O 212 CONCRETE UMPSTER PA Cs. G.P. G.P --- -- I .10 4 DRS. 0 3 Dt� G 5 e, S m m3 m I I� Z201Y PP PNEW 1'-6" L51NEW 62'-6" LV5V14 FROZ N FOOD 10 215 0 105 II II FROZEN MEAT lil lilBV.P L�"102 PRODUCE PREP. LTJ �' ii NEW 60'LVEH1 FROZEN OOD EXISTING II v EXISTING CONCRETE TRUCK PAD I105 CORRIDOR IEXISTING 4 5 D S. 4 5 DRS. 40Y4 DRS. 4 5 RS. 4 5 S. ® r---� ,----i 140 ii 1 GSAG3-12J LAG3-120, I — 20" MEAT/SEAFOOD COOLER I I 2011 1048 EXISTING ;; 1, L 34'-1"x14'-6" Q � ;G CRAY COOLER I ��„il0',' 109NEW 11' I ONDOLA C5 ROWS) 1 G.P. ® 104E EXISTING C460 4 -4 X10 -1 I Q , _ �• G.P.------- A61�— — ui,' F 20n G.P. • I 20" • ® I i i I I, I I Cx.P. • ��\ MEAT/SEAFOOD PREP. cf� i i 109 G P • IK/`NH EXISTING ' 104 MEAT/SEAFOO ALES I� _M\ ii 1 _ I--- ® II ® I I4 iiI I —L 20" L -1cv I L II F— 1040 MEAT/SEAFOOD FREEZER J iiI i G E 16TING ;; I 109 M I I I 401 I I I F - 2 011 RECEIVING;; I 3 106 EXISTING 107 JANITOR ROOM ISI 1 �' l� A-14 lm9 I 101 GENERAL SALES I EXISTING 4� � � � IQ P 41 � ii I 20' MEAT STORAGE I I 20" 104D EXISTING I L - ® 0 ��I ® o - zl1 19 CV II 108 ELECtRICAL ROOM I _ EXISTING m III 2 - - - - - - G.P. TB Lu G • I i i 109 LOUNGE I i i - NEW 611 GONDOLA (2 ROWS) I _ — ® EXISTING M i i I 20 20" I 401 11 GROCERY I G (STING CONCRETE TRUCK PA ® 1� 10 STORAGE I ii 109 I I 114H SCTRAINING ROOM EXISTING X81-0111 I I L 20" - - - - - - - - I 116 WOMEN'S ROOM �40�d EXISTING i i 109 DAIRY COOLER I 111NEW 64 GONDOLA 115 MEN'S ROOM EXISTING _ EXISTING 20'-3"X20'-3" I �' LU 11 20" I I 114A INTERVIEWING /M\ II ROOM Q EXISTING I LAA3fj 5j 109 DELI/BAKERY 1 `� �' NEW 24' I HELVING NEW 40'-4" 161 BIEER 6 5 81 81 \4-02/12 02 121 0 g' NEW 8' NEW 32'-3" HZVI FRESH PRODUCE N FLORAL NEW '-I" DOL1 I MUI�TI-DECK w 0 i I v_ �v > � � . 110 �� Q ' TYP. P Q� i � U 107 `� I Uj P O2 z 01 } II X I I O; O Z ' 107 �' Ila? - 4.8 I I I I G I q 225 I I I I 100 VESTIBULA I I � IEXISTINGJ I ' 3.9 TYP.— z G i i OC �224 I I _ U �LLJ 0 ' i 121 3.1 — --------- % I I 3.6 3.4 I I FIXTURE GONDOLAS REF. 2 -DECK PRODUCE CASES REF. PRODUCE MD. SALAD CASES 4' PRODUCE EURO TABLES NOT CASE DELI SERVICE CASE ISLAND BAKERY DISPLAY S.S. BAKERY CASE DONUT CASE SELF SERVICE SEAFOOD CASE SINGLE DECK FRESH MEAT GASES REACH -IN FROZEN MEAT DOORS MD. FRESH MEAT CASES DELI MEAT CASES DAIRY PROMO TABLES (1) MULTI DECK DAIRY CASES BEER REF. CASES REACH -IN FROZEN FOODS DOORS FLORAL MERCHANDISER (WALL UNIT) NO. DESCRIPTION B -BAKERY 110 OCTAGONAL TABLE 212 DRY BAKERY (DONUT CA D - DELI 212 SS. CHICKEN WARMER 412 S.S. COLD DELI CASE I - � Z� M ii >p �O ----------------------------------------------------- ------------------------------------------------- REVISION LOG 40 STATE REGISTRATIONS 40 109 40 #8343 ---------------SC #98033----------- 140 ----------------------------------------------------- TO TFE BE&( OF TI -E i0MIEME OF TFE AFIC lfrE S AMD e"EEFF; W RAMS AND SPECFICAW,18 CCWLY VATH THE APPLCA13LE MMA1M EOLDW CODES AND THE APPLICABLE MMMW FFE SAFETY SfANIAFUS. I I 113 CASE GUARD \40X5 Di�S. 4 5 DRS. 122 PAY NE SII �N ro 4 127 RECYCLE BIN - 203 CHECK-OUT REGISTER _ o 1 F-1 ��1 206 ELECTRIC WATER COOLER Dw NEW 208 ICE MERCHANDISER SII z 210 ATM MACHINE L X11 I NEW 60' LVE)V14 FROZEN FOOD nil PRODUCE F4 1;1 STORAGE 103 FREEZER MEXISTING 7NEW COOLER 1�1 EXISTING 4 911 65' GONDOLA Il' -4"X21'-2" L> -Ll FN' Il' -4"X23'-1" �'i_ — I I8I I Til L- 20" LTJ _ II G 109 61I GONDOLA 4 5 D S. 4 5 DRS. 40Y4 DRS. 4 5 RS. 4 5 S. ® r---� ,----i 140 ii 1 GSAG3-12J LAG3-120, I — 20" MEAT/SEAFOOD COOLER I I 2011 1048 EXISTING ;; 1, L 34'-1"x14'-6" Q � ;G CRAY COOLER I ��„il0',' 109NEW 11' I ONDOLA C5 ROWS) 1 G.P. ® 104E EXISTING C460 4 -4 X10 -1 I Q , _ �• G.P.------- A61�— — ui,' F 20n G.P. • I 20" • ® I i i I I, I I Cx.P. • ��\ MEAT/SEAFOOD PREP. cf� i i 109 G P • IK/`NH EXISTING ' 104 MEAT/SEAFOO ALES I� _M\ ii 1 _ I--- ® II ® I I4 iiI I —L 20" L -1cv I L II F— 1040 MEAT/SEAFOOD FREEZER J iiI i G E 16TING ;; I 109 M I I I 401 I I I F - 2 011 RECEIVING;; I 3 106 EXISTING 107 JANITOR ROOM ISI 1 �' l� A-14 lm9 I 101 GENERAL SALES I EXISTING 4� � � � IQ P 41 � ii I 20' MEAT STORAGE I I 20" 104D EXISTING I L - ® 0 ��I ® o - zl1 19 CV II 108 ELECtRICAL ROOM I _ EXISTING m III 2 - - - - - - G.P. TB Lu G • I i i 109 LOUNGE I i i - NEW 611 GONDOLA (2 ROWS) I _ — ® EXISTING M i i I 20 20" I 401 11 GROCERY I G (STING CONCRETE TRUCK PA ® 1� 10 STORAGE I ii 109 I I 114H SCTRAINING ROOM EXISTING X81-0111 I I L 20" - - - - - - - - I 116 WOMEN'S ROOM �40�d EXISTING i i 109 DAIRY COOLER I 111NEW 64 GONDOLA 115 MEN'S ROOM EXISTING _ EXISTING 20'-3"X20'-3" I �' LU 11 20" I I 114A INTERVIEWING /M\ II ROOM Q EXISTING I LAA3fj 5j 109 DELI/BAKERY 1 `� �' NEW 24' I HELVING NEW 40'-4" 161 BIEER 6 5 81 81 \4-02/12 02 121 0 g' NEW 8' NEW 32'-3" HZVI FRESH PRODUCE N FLORAL NEW '-I" DOL1 I MUI�TI-DECK w 0 i I v_ �v > � � . 110 �� Q ' TYP. P Q� i � U 107 `� I Uj P O2 z 01 } II X I I O; O Z ' 107 �' Ila? - 4.8 I I I I G I q 225 I I I I 100 VESTIBULA I I � IEXISTINGJ I ' 3.9 TYP.— z G i i OC �224 I I _ U �LLJ 0 ' i 121 3.1 — --------- % I I 3.6 3.4 I I FIXTURE GONDOLAS REF. 2 -DECK PRODUCE CASES REF. PRODUCE MD. SALAD CASES 4' PRODUCE EURO TABLES NOT CASE DELI SERVICE CASE ISLAND BAKERY DISPLAY S.S. BAKERY CASE DONUT CASE SELF SERVICE SEAFOOD CASE SINGLE DECK FRESH MEAT GASES REACH -IN FROZEN MEAT DOORS MD. FRESH MEAT CASES DELI MEAT CASES DAIRY PROMO TABLES (1) MULTI DECK DAIRY CASES BEER REF. CASES REACH -IN FROZEN FOODS DOORS FLORAL MERCHANDISER (WALL UNIT) NO. DESCRIPTION B -BAKERY 110 OCTAGONAL TABLE 212 DRY BAKERY (DONUT CA D - DELI 212 SS. CHICKEN WARMER 412 S.S. COLD DELI CASE I - � Z� ------------------------------------------------- ------------------------------------------------- ----------------------------------------------------- ------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL---#AA001'935--------NC_ 109 GONDOLAS #8343 ---------------SC #98033----------- UU ----------------------------------------------------- TO TFE BE&( OF TI -E i0MIEME OF TFE AFIC lfrE S AMD e"EEFF; W RAMS AND SPECFICAW,18 CCWLY VATH THE APPLCA13LE MMA1M EOLDW CODES AND THE APPLICABLE MMMW FFE SAFETY SfANIAFUS. 113 CASE GUARD 122 PAY NE 127 RECYCLE BIN - 203 CHECK-OUT REGISTER _ o 1 206 ELECTRIC WATER COOLER NEW 208 ICE MERCHANDISER 5,ERVICE 210 ATM MACHINE r WONALLE— I I I J IN OC1 A ONA ' TA LE LU I I f NEW , � OCTADO�1 L I Z 112 EXILi STING n+ c4 ii L - 20" G Ca G G Y_ Q TABLE W ❑ I I II L- 2011 8 � 12 � 12 8 D Q �1� I to II NEW 21' SHE1_ING m - 412 O ui,z IO ICE CREAM FREEZER '- XAG5-180 -' 40 z I' G 0 0 0 U I1 z z 113 L ----J LU 4 4 4 S 4 S W 11 EXISTING 109 z a Z � -qI I > 11'-7"X14'-6" II G cp � ��mli � I II G. NEW 40' IV5VI4 I E CREAM CD -j I i i TYP. 0 I I SECURITY ROOM 114 EXISTING G ii NEW 8'-1" IL1 1 0 ii DAIRY PROMO NEW 100'-0" D6L DAIRY Ir I —;iim II— CfGE 211 VERTICAL BALER 118A (E:XI TING 212 DUMPSTER 220 COIN STAR 1188 5LTORAGE 222 WATER VENDOR ROOM 224 SECURITY PEDESTAL (EXISTING) 225 MART CART I 2.5 401 MULTI -DECK DAIRY CASE 402 MULTI -DECK BEER COOLS — - - 2.4 1 403 REACH -IN FROZEN FOOD A-16 i i 404 REACH -IN ICE CREAM I`ll ; I ; 11tE DELI/BAKERY 405 DAIRY PROMO I I I cooLER r i i (EXISTING) M -MEAT I I I 6 10 x10 8 401 SERVICE MEAT CASE 402 MULTI -DECK FRESH MEAT .> U 403 DELI MEAT CASE 408 FROZEN MEAT DELI/BAKERY III 111 SALES P -PRODUCE 101 WORK DESK 105 WORK TABLE 122 i 107 PRODUCE EURO TABLE 111A DELI/BAKERY 110 HANGING SCALE I I �P. 111 BOAT RACK 203 SCALE I I 222 i i 206 TOP COUNTER WRAPPER III 209 ICE MACHINE L 14 �II(1, I 210 HAND SINK FROZ DELI zii� ® I I 211 3 COMP. SINK 215 2 COMP. SINK G G I G G G I G G G I I I G3-12 �i 8' 01 g' 01 12' 01 12' 01 12' 01 1 01 4 12' 01 12' Ol 12' " LILj - - _ - 1.1 402 TWO -DECK DE K F ERODUCE � H PRODUC 403 M_ p. SPECIAL PRODUCE C X16TING SPRINKLER RISER I 1 AND SIAMESE CONNECTION L — J IMSA CORROOR 02 I I 11tD DXIST EXISTING H G F_5 p_.� G.P. 6.P. SGP O O 1 1�1 DELI/BAKERY FREEZER J EXISTING A-14 I S -SEAFOOD 405 SELF SERVICE SEAFOOD C g AI.I q TRUE NORTH PLAN NORTH FIXTURE LEGEND PROV. 1418 LFT. 68 LFT. 8 LFT. 12 TABLES 6 LFT. 22 LFT. 12 TABLES 8 LFT. 5 LFT. 8 LFT. 56 LFT. 7 DOORS 36 L. FT. 36 LFT. 8 LFT. 100 LFT. 40 LPT. 91 DOORS 8 LFT. EXIST.1 MANUFACTURER/MODEL • C C 0 C F K 310 Ew 00 No No 11311111111110. Mc 311110 a■ S• {7 T M12 LV5V14 IV5VI4 M4AL1 1. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR CENTERLINE OF COLUMN UNLESS OTHERWISE NOTED. 2. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH DRAWINGS AND SPECIFICATIONS OF ALL APPLIGABLE TRADES AND ENGINEERING DISCIPLINES. 3. G.C. SHALL INSTALL GRAVITY SCALES AND BAG RACKS SUPPLIED BY KASH N' KARRY. 4. THIS PLAN IS PROVIDED FOR COORDINATION PURPOSES ONLY. ALL FIXTURE DEMOLITION/REPLACEMENT/REPAIR WILL BE (N.I.C.) AND WILL BE COVERED BY THE REFRIGERATION CONTRACT. SCALE I FIXTURE PLAN 3/32"=1'-0" 1 GENERAL NOTES ARCHITICTURI [US I N T E R N A T 10 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813,281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com License #AAC001935 r Kash n' Karry ©AS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Z� ------------------------------------------------- ------------------------------------------------- ----------------------------------------------------- ------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL---#AA001'935--------NC_ #50985 ---------- GA- ----------------------------------------------------- #8343 ---------------SC #98033----------- UU ----------------------------------------------------- TO TFE BE&( OF TI -E i0MIEME OF TFE AFIC lfrE S AMD e"EEFF; W RAMS AND SPECFICAW,18 CCWLY VATH THE APPLCA13LE MMA1M EOLDW CODES AND THE APPLICABLE MMMW FFE SAFETY SfANIAFUS. KASH N' KARRY NO.1890 SANFORD,-- FL ------------------------- PROJECT NAME FIXTURE PLAN ______________________ SHEET NAME PROJECT- NUMBER: 9949.01 ---------------------------------------------------- DRAWN- BY: DR CHECKED- BY: API --------------------------------------------------- SCALE: AS NOTED - ---------------------------------------------------- ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE - - FOR: -BID/PERMIT -------------------------------------------------- --------------- A�_1_2 ----------------- SHEET NUMBER I m S ARCHITICTUR[ [US I N T E R N A TI O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813281,9292 E—Mail api@architectureplus.com License #AAC001935 I, Dash n' Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL #AA001935 NC_ #50985 GA ----------------------------------------------------- #8343 ---------------SC #98033_---------- ----------------------------------------------------- TO_ T}E BEBi CF TI -E K4OftEDCE OF TFE AFCNTEM *0 SFECFCATCPS COVKY WITH THE APPLCA13LE MAN BULM AND TFF ArD APPLJCAB.E MJLW FFE SPFEfY STAMI4FT)6. KASH--N'----- KARRY N-0.1890 ------------------------------------------ SANFORD,__ FL ------------------ PROJECT NAME FLO-ORING ---------------------------------------------------- PLAN ----------------------------------------------------- SHEET NAME PROJECT- NUMBER: 9949A1 ---------------------------------------------------- DRAWN BY: DR CHECKED- BY: API DRAWN­BY. SCALE AS NOTED ----------------------------------------------------- ISSUE DATE 9/06/01 ----------------------------------------------------- ISSUE FOR: BID/PERMIT ----------------------------------------------------- SHEET NUMBER SUSPEND "PRELUDE XL 360" CEILING GRID OPEN SYSTEM AND "AXIOM" EDGE W/#6 (1/161) BRAIDED CABLE, GALVANIZED STEEL HANGER WIRE FROM EXISTING GRID ABOVE, AT 48" GRID INCREMENTS MAX. INSURE THAT SUSPENSION WIRES ARE PLUMB. TRACK LIGHTNG SUSPENDED TO 8'-8" A.F.F. TO TOP OF TRACK. LENGTH AS INDICATED. "AXIOM" AND "PRELUDE XL 300 MSTR — GRID PROFILE AND 8" "AXIOM" PROFILE. FACTORY FINISHED WHITE Al It �1= �o \ IL DEPARTMENTAL SIGNAGE/o? \ ARC * 3 R=56'-2" 1 -1 L=24'-8 5/32" Ro w1l SURFACES. L I �� BENCH MARK/START POINT Q OF GRID LAY OUT. I _ I 0 16'L. k, � I I� — 24"X24" GRID \IF RI III II R=33'-3"Li�I— L=39'-100" � <\ -� � I � � JI MAIN T -BAR GRID TO TRUN iRPWA L. I I IL III I Ell �:]�I I*I r—_i L _ J IL I �_. I �_�_u / \ I— __j12 JI / \ NOTE: — — — EXISTING SPRINKLER HEADS TO REMAIN L UNDISTURBED. m =� 2'-00"TYP TRACK LIGHT z4 2'-O m DELI/BAKERY "AXIOM" CEILING II I I 11 I I —II II I TRACK LIGH�'ING C L _ JI II SCALE 3/16`=1'-0" TRACK L IGHTNG SUSPENDED TO 8'-8" A.F.F. TO TOP OF TRACK. LENGTH AS INDICATED SUSPEND "PRELUDE" CEILING GRID OPEN SYSTEM AND "AXIOM" EDGE W/06 (1/1611) BRAIDED GABLE, GALVANIZED STEEL HANGER WIRE FROM EXISTING GRID ABOVE, AT 48" GRID INCREMENTS MAX. INSURE THAT SUSPENSION WIRES ARE PLUMB. ARCO 3 R=69'-11 1/4" L=36' -m" OIL EL -=V-0" AFF 24"X24" GRID MAIN T -BAR GRID TO RUN PERPINDICULAR TO SOFFIT WALL. "AXIOM" AND "PRELUDE" BY ARMSTRONG. 15/16" GRID PROFILE AND 8" "AXIOM" PROFILE. FACTORY FINISHED WHITE, ALL SURFACES_ MITER CORNERS (TTP.) EA I NO. I DESCRIPTION S 405 5 -BAKERY 301 206 101 WORK DESK 105 WORK TA5LE_ 109 BREAD SLICE 110 ISLAND BAKE' 116 S.S. TABLE W/P -1 120 BOAT RACK U M 2(03 106 108 106 2005 ELECTRICAL f 208 20-i AIR BSH GL M ABV RU208 KOPY KA M 105 209 DONUT GLAZE 109 214 HAND SINK ABV. 211 CAN WASH M 20930121x0 3f03 RE OORDER 1„ 1 109 ABV 1(05 1..1 305 DONT FRYER 1005 — — — — — 207 308 20 QT. MIXER 313 SINGLE RACK M 4001 SERVICE CAS] 212 MEAT/5EAFOOD PREP. D -DELI 1sa4A 105 WORK TABLE M M 1108 BOAT (RACK LITY c 213 214 M 2003 CASH REGISTE 407 204 SCALE 200-1 COU T RTOF X)<X 208 COUNTERTOP 209 SLICER 213 HO C SE 216 HAND SINK 1„1 211 3 COMP. SINK 101 218 CLEANING/SAi 221 CONDIMENTS r 222 1 CO P. SCALE 225 IIN � CO P. SI :NLARGED MEAT/SEAFOOD PREP FIXTURE PLAN SCALE Q„ L 1/4"301 E EG o R 303 CHICKEN FRYE 305 EXHAUST HOC 306 MICROWAVE CUSTOMER 5ERVICE 311 RANGE/OVEN IIS 4001 ERV CE COLI if 413 FROZEN DELI 414LT F M -MEAT / — — — — — 101 WORK DESK I 1005 WORK T 8L E loci BOAT R C 201 SCALE `R'STEr �/ ml ► LIISA OFFICE 208 SLICER I� 18R STORAGE ROOM 209 GUBER (� 210 SAW 212 LARGE GRIND' 110 213 HARD SINK / 214 3 COMP. SINK / i I—� ---- ----1 401 SING E DIEL >S -SEAFOOD D w204 4D 106 S.S. UTILITY TA D D U08 E30AT RACK_ 203 SCALE i m 4m1 216 222 liB DEL I/BAKERY COOLER / I I D D 206 TOP CO NTER 204 / i I 218 3001 STEAMER � D 00 / 11100 - I 8 45 SELF SERVICE / JJ ABV- I I ABV. -110 PR///� 30 BV. I I D // Z�_ D 3(03 1 221 // D 225 1 2004 p I I I U � I 311 I I 209 I I I 1 � ABV. I II p I I D 1 1 2(03 I D lm ® 108 p I 100a I I 3x01 D Iz 2m8 20 I I 110 ABV. 1005 I I 7 --- IS, I Q N D r -1 20-1 105 B I B I 2008 'Iwo 1008 = 21D3 I 308 8'-10" LONG B l>m '� 116 209 I I B EXIST. WALL 2m9 =L 1200 ABV. 1� I I� 117A DELI/BAKERY PRE 3m1 IIz 1 1 1 � 214 UFIXTURE LEGEND I I�w F_ IfQ� 1 � B EXIST. MANUFACTURER/MODEL (NEW FIXTURES) • • RELOCATED • • RELOCATED • KOPY KAKE AIRBRUSH SET KOPY KAKE PROJECTOR • • • • • BKI DNF -F • Q;=1 nrA-r;=n 0 0 0 0 A n C M IL-1- V5VI4 1 1_1 4®1 I 1. ALL DIMENSIONS ARE TAKEN TO FACE OF WALL OR CENTERLINE OF COLUMN UNLESS NEW 5 1 1 �r 1 313 OTHERWISE NOTED. LV5V14I IW U_ B I 2. THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH DRAWINGS AND SPECIFICATIONS FROZEN pEL 1 I Iz ww 1m9 IHC DELI/BAKERY FREEZER L — — OF ALL APPLICABLE TRADES AND ENGINEERING DISCIPLINES. 1 1 B 3. G_C_ SHALL INSTALL GRAVITY SCALES AND BAG RACKS SUPPLIED BY KASH N' KARRY. I I lm1 B rOE, 21-1 D 413 414 11 MEAT/SEAFOOD PREP. "AXIOM" CEILING3/16ALE1,a„ 2 ENLARGED DELI/BAKERY FIXTURE PLAN SCALE 1 GENERAL NOTES 1/4 -1 0 ARCHITICTUR[ [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813281.9292 E—Mail api@architectureplus,com License #AAC001935 /'Dash n' harry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL#AA001935 NC_ #50985 ---------------------------------------------------- GA --#8343 --------------- SC#98033----------- �jt a� ----- ----------------------------------------------- TO THE BEST OF THE WAIEDGE OF TFE AFICHREOTS AND UCNEEF , SAO FLAAS AAD SPECFCATICNB DOWLY WITH THE AFPOCABLE NVI UM BL&ONG CODES AND THE AFPIJCABLE MNMUM FFE SAFETY STANDAFM KASH__N' __KARRY --- NO. --1-890 SANFORD,__ FL______________________ PROJECT NAME ENLARGED __FIXTURE AND REFLECTED CLG. ----------------- SHEET NAME PROJECT NUMBER 9949.01 DRAWN BY: DR CHECKED BY: API SCALE: AS NOTED ----------------------------------------------------- ISSUE DATE: 9/06/01 ISSUE FoFtBID/PERMIT ------------------------------------------- --------------- A�_1_4 ---------------- SHEET NUMBER I" f I N I I 0 ARCHITICTURI 1V I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813.281.9292 E -Mail api@architecturep us,com License #AAC001935 /,bash n Karry OAS DATED ARCH ITECTUREPLUS INTERNATIONAL, INC. 0 Z� OPENING FOR FILM ARCHITICTURI 1V I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813.281.9292 E -Mail api@architecturep us,com License #AAC001935 /,bash n Karry OAS DATED ARCH ITECTUREPLUS INTERNATIONAL, INC. Z� OPENING FOR FILM ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL#AA001935 ------ NC_ #50985 ---------------------------------------------- DROP. 2"x 8" OPENING #8343 SC #98033 O� V ----------------------------------------------------- TO TFE BEST OF TFE IQJCNJL DGE OF TFE AFCNIECTS AND RUIEERS, SAD BANS AND SPECT I TIONS COWLY WITH TI -E APPUCABLE MNWM BI.IDNG CODES AN) TFE AFPUCABLE MNMW FFIE SAFELY STAPDAftS. W/3/4" x 3/4" x 1/8" ALUM. EDGE GUARD. 3'-1" PLLAM."I PLLAM."I 3'-r' X"I PLLAM.M 3'-I" PL.LAM.1 PLLAM.�I I' -m" t" 3/4" X 3/4 X 1/8" I'-3 i/4" r -r' 3/4"PL.L t' ALU X 3/4 X GE ALUMINUM EDGE AS REQUIRED VERIF t" ALUMINUM EDGE GUARD. F 3/4" X 3/4 X I/8" 6„ GUARD I 6" SLIDING DOORS W/rOP ALUMINUM EDGE C m 3/4" X OAK EDGE = AND BASE TRACKS, 6" GUARD REGISTER SCANNER/SCAL = - DRAWERS W/ STEEL FRAMING RECESSED BALL -BEAR GLIDES 4 RECESS. PULL 2'-0" PLLAM.02 PROVIDED 4 INSTALLED 'BY SCREW OTHER"/HOLE CUT IN TOP Y ATTACHED , J SIDE PANELS 4 FULL 1/4" TEMP. HANDLES CHW-1 8° t. m„ t'-6" GENERAL CONTRACTOR m REMOVABLE 3" 6" = EXTENSION GLIDES e (STYLE/SIZE AS INDfC.) GLA55 CA5E SUPPORT POSTS FOR SHELF BRACKETS (3EA.) P PANEL 3/4 MED. PENS. - CHW-5 W/ SEC. GLASS FRAMES 4 SUPP! PLLAM."2 3/4" MEDIUM DENSITY PLLAM.02 FIBER/PARTICLE BP. _ C CHW-11 PLLA .02 FIBER/PARTICLE BOARD `" c (TYP.-U.oN.) m m N C STANDARDS 4 GLASS �4Ii1INE INE l TYP: U.ONJ DOOR/DRAWER e e SHELF SUPPORTS W/ 3/4" M DIUM DENSITY SLAT WALL 0 _ C PULL HANDLES SLAT WALL r C - m NEOPRENE GASKETS FIRE ARTICLE MONIT > BOAR).- PL *2 WOOD SPACER FURRING AT `" v CHW-2 P m `� LINE OF GAB. "' (10" SHELF) CNW-4 (SHELF, = (T .ON.) TOP 4 BOTTOM AND 16" O.G. VERTICAL�}� n IN = PLLAM."2 1x3/4 WD. SPACER FURRING AT TOP M PULL BEYOND. TEMP. MONITOR t -m t t/z� FULL EXTENSION 4 BOTTOM 4 16 O.G. MELAMINE CNW-2 3/4 MED. DENS. PLLAM. 1/4" THK PLLAM."2 = DRAWER VERTICAL. FINISH = PLLAM"2 FIBER/PARTICLE BOARD DOOR/DRAWER PULL = HANDLES CHW-2 KEYBOARD I-1/2" 1/8" ALUM. KEYBOARD ANLL PULL/STOP -� mE:7 � GLIDES /CHW-6 2" DIA. HOLES PLLAM."2 v FULL EXTEN5. -U.ON.) DRAWERS W/ STEEL SIDE = CART EDGE GUARD GHW-9 IN FRAME FOR �+ ELECT. 4 DATA m DRAWER GLIDES CHW-6 PLLm 330H/22 _ = PANELS 4 FULL EXTENSION GLIDES (STYLE/SIZE AS INDICATED) CNW-5 CABLES cq RT EDGE GUARD CART EDGE - VINYL COVE BASE t'_m" n 6.. v CHW-9 = CHW 3 = 2" DIA. HOLES IN FULL EXTENSION KEYBOARD VINYL COVE BASE � m FRAME FOR ELECT. v m FRAME FOR ELECT. 4 DRAWER GLIDES 6" z'-4" z" VINYL COVE BASE `^ _ 4 DATA GABLES VINYL COVE BASE m _ 6' 4 DATA CABLES / CHW-6 OPENINGS FOR DATA z'-6' I' -m" " 6" VINYL COVE BASE v `" VINYL COVE BASE CABLES 2" 6" BASE CABINET V-6" AS INDICATED BASE CABINET DETAIL SCALED BC16 BASE CABINET DETAIL SCALED BC15 BASE CABINET DETAIL SCALE BC6 BASE CABINET DETAIL SCALED ��� 1 111=11-011 A55REVIATION5 PB PEGBOARD BG BASE CABINET E35 BACK 5PLA5F-1 PL.LAM.* 3'-t" PL1_AM.*1 PLL " ."IAM.1 3'-IPL.LAM ° AS REQUIRED 5" IIZI W. -ALUM. EDGE GUARD BC26 LK LOCKABLE DRAWER F 6" 3/4" X 3/4 X 1/8" ALUMINUM EDGE = END/CLOSURE3'-r' 3/4" X 3/4 X 1/8" ALUMINUM EDGE PLLAM."1 PL PLASTIC LAMINATE `C LOTTO TICKET DISPENSES, GUARD PANEL BEYOND - GASH REGISTER PLLAM.*2 GUARD - PROVIDED 4 INSTALLED ' Y OTHERVHOLE CUT IN TOP BY m t C 6' 5" 4 3/4" X 3/4 X 1/8" VB VINYL BASE GENERAL CONTRACTOR PL.LAM."1 EL T/DATA = CE CASH DRAWER SHELF_ DOOR/DRAWER `C 6 ALUMINUM EDGE EDGE GUARD 4"x4"A/4" STEEL - PULL HANDLES = m PLLAM."2 WS WALL SHELF/SURFACE 17 3/4„ MEp. DENS. m ANGLE BRACES. 2 EA. REOD. CNW-2 GASH DRAWER SHELF - FIBER/PARTICLE BD. (TYP.-U.O.N.) DOOR/DRAWER PULL HANDLES FILE EXPOSED EDGES. _ 330M/22" DRAWERS W/ STEEL m a M�qM l GHW-2 3/4" MED. DENS. a SIDE PANELS 4 FULL EXTENSION 4 POOwHDANDLES FINISHES fI�ISH rl 1S+t PLLAM."2 FIBE"ARTICLE BD. (TYP.-U.ON.) GLIDES (STYLE/SIZE AS INDICATED) 3/4" MEDIUM DENSITY FIBER/PARTICLE BOARD e m CHW-2 PLLAM.M2 SLAT WALL m - s m C fNE CNW-5 ..) (TYP-UDN 33OH/22" _ - PL*1 WILSONART/TAWNY LEGACY/4663-60 PL "2 m SLAT WALL. `; FINS FI SLAT WALL 1x3/4" WOOD SPACER x3/4" WD. SPACER L 02 ADJUSTABLE SHELF WOOD SPACER FURRING AT = PL*2 WILSONART/MAN1T01BA MAPLE/7911-60 FURRING a TOP 4 1507. 4 16" O.C. VERTfCAL REMOVABLE PANEL FOR ACCE ADJUSTABLE SHELF WA WALL STANDARDS FURRING . TOP 4 BOTToM 4 16" O.C. W/ WALL STANDARDS REMOVABLE PANEL FOR AGCES 4 CLIPS /CNW-3 TOP 4 BOTTOM AND Ib" O.G. VERTICAL M L� FI IS I PLLAM."2 TO ELECJDATA LINES BELOW. 4 CLIPS /CHW-3 VERTICAL. TO ELECJDATA LINES BELOW. - PLLAM.'7 PROVIDE 2" SQ. NOTCH IN PANE PLLAM."2 - REAR CORNERS FOR CABLES.j. CONCEALED SELF- PLIAM.*2 �* PROVIDE 2" SQ. NOTCH IN PANE REAR COMERS FOR CABLES. CONGEALED SELF- PLLAM."2 _ - - 1\CHW-I CART EDGE GUARD CLOSING HINGES m CLOSING HINGES CHW-1 i L330H/22" < 2" DIA. HOLES CHW-9 a 2" DIA. HOLES IN CART EDGE GUARD 1 2" DIA. HOLES IN CART EDGE GUARD GNW-9 -A M FOR �` FRAME + + + + + F ME FOR ELECT. 4 PI GABLES GHW-9 v + + + + + FRAME FOR ELECT. _ `� �, 4 DATA GABLES ABBREVIATIONS VINYL COVE BASE = v r -m" n 6" `� VIINYL COVE BASE , , VINYL COVE BASE = 4 DATA CABLES_ r -m" n 6" VfNYL COPE BASE VINYL COVE BASE m r -m" - 6" VINYL COVE BASE r rollz.. z.. I, 611 I, 2' HDWR ��. -,� MARK DESCRIPTION MNFR MODEL/SERIES NOTES GHW-1 CONCEALED HINGES BLUM 11M3550 SELF-CLOSING OVERLAY GHW-2 DOOR/DRAWER PULLS EPCO DP -412A CLEAR ANODIZED CHW-3 SHELF STANDARDS KV 255AL 4 256 ALUMINUM/NATURAL 4 CLIPS (WOOD) CNW-4 SHELF STANDARDS KV 450013 4 4 SAWS SUPPORTS (GLASS) 232010 W/RUBBER CUSHIONS BASE CABINET DETAIL SCALE BC3 BASE CABINET DETAIL SCALE BC2 BASE CABINET DETAIL SCALE BC1A _ 1'-1'-0' , _o„ ,"'_o" CHW-5 DRAWER SIDE PANELS BLUM "METABOX" FULL EXTENSION, SELF-CLOSING, W/RUNNERS/GLIDES STEEL HTJLGTH. AS INDICATED CHW-6 DRAWER RUNNERS/GLIDES BLUM 430E FULL EXTENSION, SELF-CLOSING, HTJLGTH. AS INDICATED 3611H H.C. ACCESSIBLE COUNTER FILM 2A A_I6 GNW-7 SLIDING DOOR ROLLERS 4 STYLMARK 610141 DOUBLE TRACK /SECURITY CREDIT DROP TRACKS SCANNER I-- --� FILM DISPLAY GASES SCANNER/ scALE lBGl6 , DROP GHW-8 COMPRESSION BAR W/ 415 KV LK LK KEYBOARD ---____-_j ` 2'-�✓" BASE TRACK --------------I PLi / \ TS o LK REMOVABLE PANEL PNp ILM CASH DRAWER p P o LK 2B .� A 16 GNW-9 CART BUMPER GUARD McCUE C52-120- FWALL-401 SELF-CLOSING OVERLAY. COLOR: 0149 "LAVENDER" --t PANEL LK Ko .�`` � ,4 O CHW-10 ADJUSTABLE DRAWER FOR 1/2'� PLYWD. DIVIDERS AT LK TRIM `,\ �, ` , G�� 5C4 DIVIDER BRACKETS 1/2" INCREMENTS I BG6 SIM_ 5C6 \ C �G ° aBC4 O 33 k G� CHW-11 GLASS FRAMES/CHANNELS STYLMARK 510198 TOP SECURITY TYPE CHANNELS ELEVATION_(: SIM. �G�� o G '� �� ELEVATION ELEVATION E D 3 a F6 CABINET HARDWARE AND FINISHES 36"H H.G. ACCESSIBLE MON! tOR COUNTER �. G SCANNER/ 'D SCALE FILM C�>� 2E O DROP SCANNER/ SCALE SCANNER G rQ A-16 0 BCI6 KEYBOARD _ DISPLAY CASE 2C LOTTO TICKET 5�� DISPENSER A ca p 1. ALL MATERIAL AND WORKMANSHIP SHALL COMPLY WITH AMERICAN GRADE QUALITY. WODWORK INSTITUTE (AWD FOR "PREMIUM" H.G. COUNTER PL,r2 I r SLATWALLi eLYWp 7. 3LC) PANEL - LATWALL U 2D UPB 2. ALL CABINETRY SUBSTRATE/FRAMING SHALL BE 3/4" MEDIUM DENSITY UNLESS OTHERWISE NOTED. FIBER/PARTICLE BOARD (MDFB) 5LATWALLtND OAK EDGE -N\ TRIM I A-16 4 pOBPLAYO (XIS .1 3. ALL EXPOSED AND SEMI -EXPOSED INTERIOR CABINET SURFACES, DRAWERS, AND DOORS SHALL HAVE WHITE "MELAMINE" FINISH ----- ------ ---- WEDGE 111EDGE -- ----- - --- ------ - --- ----- ----- ----- ------ -- �� ------ - --------- BCIA SIM. 51M. I BG6 BGIS 5C2 BC3 BC6 WEDGE PL"2 ----- - SIM. BC BG6 SAFE Bch Bch CARL BUMPER Bch 8IM. BC6 WEDGE (EXIST.) 4. ALL EXPOSED AND SEMI -EXPOSED EXTERIOR CABINET AND COUNTER TOP SURFACES SHALL RECIEVE GUARD (TYP) 51M• SIM. PLASTIC LAMINATE FfN151-1 AS INDICATED. ELEVATION ELEVATION C ELEVATION B A 5. ALL GLASS TOPS, FRONTS AND SHELVES USED IN DISPLAY CASE (5C4) SHALL BE 1/4" TEMPERED GLASS WITH POLISHED EDGES. 6. ALL MDFB ADJUSTABLE SHELVES SHALL BE NOTCHED ON THE BOTTOM/UNDERSIDE TO FIT OVER SHELF BRACKETS/CLIPS. 1. ALL CABINETRY DRAWERS AND DOORS SHALL BE A FLUSH OVERLAY DESIGN. 8. CAFE DOOR BY MILLWORK. INSTALLER ELEVATIONS - MILLWORK 2 ENLARGED CUST. SERV. CALE 1 GENERAL SHEETNOTES BALE , 3 o ARCHITICTURI 1V I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813.281.9292 E -Mail api@architecturep us,com License #AAC001935 /,bash n Karry OAS DATED ARCH ITECTUREPLUS INTERNATIONAL, INC. Z� ----------------------------------------------------- ----------------------------------------------------- ----------------------------------------------------- REVISION LOG STATE REGISTRATIONS ----------------------------------------------------- FL#AA001935 ------ NC_ #50985 ---------------------------------------------- GA ----------------------------------------------------- #8343 SC #98033 O� V ----------------------------------------------------- TO TFE BEST OF TFE IQJCNJL DGE OF TFE AFCNIECTS AND RUIEERS, SAD BANS AND SPECT I TIONS COWLY WITH TI -E APPUCABLE MNWM BI.IDNG CODES AN) TFE AFPUCABLE MNMW FFIE SAFELY STAPDAftS. KASH__N' __KARRY--- N-0. 1890 SANFORD,-- FL ------------------------- PROJECT NAME MILLWORK __AND -------------------- DETAILS ----- ___________________DETAILS_____ ---------------------------- SHEET ___SHEET NAME PROJECT NUMBER: 9949.01 DRAWN BY: DR CHECKED BY: API SCALE: AS NOTED ISSUE DATE: 9/06/01 ----------------------------------------------------- ISSUE -FOR:-BID/PERMIT- -------------------------------------------------- --------------- A--1-6 ----------------- SHEET NUMBER i KEY NOTES �N WIRE NEW LIGHT FIXTURES TO CIRCUIT INDICATED. FIELD 'VERIFY L U1 XIS MS C EXISTING EMS CONTROL ZONE OF EXTERIOR LIGHTS. WIRE NEW FIXTURES TO BE CONTROLLED THROUGH EXTERIOR EMS ZONE. G WIRE NEW LIGHT FIXTURES TO EXISTING CIRCUIT 'LEFT FROM DEMOLITION PHASE. EXTEND WIRING AND CONDUITS AS REQUIRED. H SEE DEMOLITION GENERAL NOTE f2 ON SHEET E-11). T 03 EXISTING EMERGENCY EXIT LIGHT FIXTURE WITH BATTERY BACKUP TO REMAIN. TRACK LIGHTS SHALL BE SUSPENDED AT 9'-0- A.F.F. PROVIDE N SO CORD ASSEMBLY HARDWIRED TO A JUNCTION BOX FLUSH WITH CEILING. PAINT BOX COVER TO MATCH CEILING COLOR. EXISTING EMERGENCY DIGHT FIXTURE WITH BATTERY BACKUP TO REMAIN. RELOCATED WALLWASH FIXTURE TO BE MOUNTED ON TOP OF CASES AND AIMED UPWARD. SEE DEMO LIGHTING PLAN NOTE #4, UTILIZE EXISTING CIRCUIT AND CONTROL EXTEND WIRING AND CONDUITS AS REQUIRED TO NEW LOCATION. 07 CONNECT NEW TOILET FIXTURES TO EXISTING CIRCUITS AND MAINTAIN INTERLOCKING WITH TOILET EXHAUST FAN. CONNECT UNSWITCHED LEG OF BATTERY BACKUP AHEAD OF SWITCHING, TYPICAL EXISTING SURFACE -MOUNTED FLUORESCENT UGHT FIXTURE TO REMAIN. SEE DEMO LIGHTING PLAN NOTE #3 ON SHEET E-10 & GENERAL NOTES # 3 & 12 THIS SHEET. DISCONNECT EXISTING FIXTURE FROM EXISTING CIRCUIT AND CONNECT TO EXISTING NIGHT LIGHT CIRCUIT. WIRE EM. LIGHT TO UNSOTCHED LEG OF LOCAL LIGHTING CIRCUIT, 10 NEW LIGHT FIXTURES WITH REFLECTOR TO BE MOUNTED ON TOP OF CASES AND AIMED UPWARD. UTILIZE EXISTING CIRCUIT LEFT FROM DEMOLITION PHASE TO WIRE NEW LIGHTS. EXTEND WIRING AND CONDUIT TO NEW LOCATION AS REQUIRED. 11 EXISTING LIGHT FIXTURE TO REMAIN. SEE DEMOLITION PLAN, DRAWING E-11). SEE GENERAL NOTE #3, THIS SHEET. 102 WIRE NEW LIGHT FIXTURES TO NEAREST CIRCUIT INDICATED. RUN (2) #10 THWN LU. AND (1) #10 CU. GROUNDING CONDUCTOR IN 1/2' CONDUIT. SEE DEMOLITION GENERAL NOTE #2, SHEET E-1 103 TYPICAL EXISTING RECESSED FLUORESCENT LIGHT FIXTURE TO REMAIN. SEE DEMO LIGHTING PLAN NOTE #12< 14 EXISTING LIGHT FIXTURES IN THIS AREA TO REMAIN. SEE GENERAL NOTE NO, 11 THIS SHEET. 15 ELECTRICAL CONTRACTOR SHALL TAKE SPECIAL CARE IN ROUTING AND SUPPORTING OF FLEXIBLE CONDUIT FEEDING FIXTURES MOUNTED ON COMPASSO GRID, KEEP CONDUITS OUT OF LINE OF SITE FROM BELOW AS MUCH AS POSSIBLE. ALL LIGHT FIXTURES MOUNTED TO GRID SHALL HAVE ADDITIONAL AIRCRAFT CABLE TO BAR JOIST ABOVE. 106 RELOCATED WMLWASH FIXTURE FROM DELI AREA TO BE MOUNTED ON TOP OF CASES AND AIMED UPWARD. 17 JUNCTION BOX FOR NEW KASH N KARRY SIGNAGE. FIELD COORDINATE FINAL LOCATIONS AND REQUIREMENTS. WIRE NEW SIGNAGE TO EXISTING CIRCUITS LEFT FROM REMOVAL OF OBSOLETE SIGNAGE. EXTEND EXISTING WIRING AND CONDUIT AS NEEDED, PROVIDE. WEATHERPROOF DISCONNECT SWITCHES AT JUNCTION BOXES PER SIGNAGE REQUIREMENTS. 18 WIRE NEW LIGHT FIXTURES TO CIRCUIT INDICATED. PROVIDE NEW RELAYS TO WIRE THOSE LIGHTS TO BE CONTROLLED VIA ZONE #2 OF EMS SYSTEM. 19 RUN (2) #10 THWN CU. AND (1) #10 E.G. IN 3/4- CONDUIT TO PANEL 'LB' AND CONNECT TO SPARE IP -20A CIRCUIT BREAKER. PROVIDE TRIP -FREE HANDLE LOOK -ON CKT. BKR. EXISTING EMERGENCY LIGHT FIXTURE TO BE RELOCATED. EXTEND WIRING AND CONDUIT AS REQUIRED. MEZZANINE PLAN. SCALE- 3/32" = V -O" (Typ') TYPE 'G' --, (TYP-) BALANCE (3) CIRCUIT TRACK & HEADS EVENLY ACROSS THE CIRCUITS SHOWN. TRACK LIGHTING MOUNTED TO UNDERSIDE OF PRELUDE CEILING GRID, LENGTH AS INDICATED WNERAL NOMS COORDINATE LOCATIONS ................. ......... WITH PRODUCE TABLES 1. REFER TO PANELBOARD SCHEDULE FOR EMS CONTROL NUMBER OF 7. ALL JUNCTION BOXES LOCATED IN COOLERS & FREEZERS ARE TO BE LA -18,20 BALANCE (3) CIRCUIT : : : : : : : : : : : : : : - : : (T YPICAL) EACH NEW LIGHTING CIRCUIT. FIELD COORDINATE FINAL CONTROL WEATHERPROOF. AFTER WRING IS COMPLETE, SEAL ALL PENETRATIONS TRACK & HEADS EVENLY ........... CIRCUIT WITH KASH N KARRY REPRESENTATIVE. PER N.E.C. 370-15. (SEAL TO PREVENT ANY AIRFLOW.) ACROSS THE CIRCUITS Z ALL WORK SHALL BE CONCEALED, CUT AND PATCH WALLS AND/ OR 8, ALL LIGHT SWITCHES ARE TO BE MOUNTED NO MORE THAN 48" A.F.F. SHOWN. (TYPICAL) CS -LING AS REQUIRED. PAINT WALLS AND/ OR CEILING TO MATCH PER THE REQUIREMENTS OF A.D.A. G' LA -27,29,31,33,36 .... ....... G SURROUNDINGS. 9. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR RUNNING ALL WIRING TO TRACK LIGHTNG MOUNTED 18 3, ALL EXISTING FLUORESCENT FIXTURES WITH T12 LAMPS OR SINGLE ROW PANELS & CONNECTION OF ALL FIXTURES. TO UNDERSIDE OF PRELUDE j (TYPICAL FOR G: T8 LAMPS SHALL BE RETROFITTED WITH DOUBLE ROW T8 SP35 LAMPS CEILING GRID 10. ALL LAY -IN FIXTURES SHALL BE INSTALLED NTH A FLEX WHIP AND ......... ........ ......... AND ELECTRONIC BALLASTS U.O.N. COORDINATE BALLAST AND LAMPS PRODUCE TRACK SUPPORTED FROM STRUCTURE AT (2) POINTS MINIMUM AT OPPOSITE TING) WITH FIXTURE LENGTH SHOWN ON DRAWINGS. CONTRACTOR SHAH CORNERS. DO NOT DEPEND ON CEILING SYSTEM FOR SUPPORT. LICH VERIFY EXISTING CONDITIONS ON SITE PRIOR TO BID. 15 ........... ........... ........... ELECTRICAL CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR (TvI 4, ALL LIGHTING FIXTURES SHALL BE FURNISHED AND INS71ALLED BY THE ..... j . . . . . AND KASH N KARRY CONSTRUCTION MANAGER FOR EXTENT OF WORK PERTAINING .. ELECTRICAL CONTRACTOR (UNLESS OTHERWISE NOTED). TO CLEANING, RELAMPING AND REFURBISHING OF EXISTING LIGHT FIXTURES ......... TO REMAIN. IN ADDITION, ELECTRICAL CONTRACTOR SHALL MAKE ALLOWANCES 5. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ADDITIONAL FOR WORK ASSOCIATED WITH PROTECTION AND SUPPORTING OF EXISTING ....... ' G. EMERGENCY AND EXIT SIGNS IF REQUIRED AT LOCATIONS REQUESTED LIGHT FIXTURES DURING REPLACEMENT AND CLEANING OF CEILING TILES. TYPE 'G BY LOCAL BUILDING OFFICIALS. (TYP.) 2 T WITH GENERAL CONTRACTOR I ELECTRICAL CONTRACTOR SHALL COORDINATE V ... 'T 6. THE KASH N KARRY STOREFRONT SIGNAGE IS FURNISHED AND INSTALLED 0 . : : : : : : . : AND KASH N KARRY CONSTRUCTION MANAGER FOR WORK ASSOCIATED NTH BY OTHERS. THE ELECTRICAL CONTRACTOR SHALL PROVIDE PIG -TAILS, PROTECTION AND SUPPORTING OF EXISTING LIGHT FIXTURES DURING G:: APPROPIATE CIRCUITING, AND MAKE FINAL TERMINATIONS AS REQUIRED. REPLACEMENT AND CLEANING OF CEILING TILES. r .......... . ..... ........ ......... PENDANT MOUNT E2 11 qP11 9 PENDANT - MOUNT C2 11 12 11 T wj CONNECT TO SALES LIGHTING ABOVE PART PLAN DELI LIGHTING SCALE, 3/32" = 1'-0" TRUE PLAIN SCALE NnRTH NORTH IUG"'HTINU PLAN ARChITECTUREPLUS . I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 8132811.9299 Fax 813281.9292 E—Mail apiCa)architectureplus.com License #AAC001935 CHEHAYEB & ASSOCIATES, INC. CONSULTING ENGINEERS CTSE::� MR AZEFLk ST. (8f.3) 876-1415 TAMPA, FL 33609 9977 (fax) 876-0913 ISSUE DATE : 09/0611011 ISSUE FOR PERMIT CAS DATED AFrHITECTUREPWS INTERNATIONAL, INC,. A ..................................................... A................................................. Io ..................................................... A ..................................................... F—, -VISION LOG ........ ..................... ... To nF- I .... M&I... I ......... f7 ST Cr'aC- tMAMM Or T1 E -*0 E= -EP: ..... .......... 4 0 .... ........... ............ 4 1.... ...... ........... ..... . .. . ....... .... ........... .......... ..... .... ... ..... ...... U ... ... ..... .......... T ..... ..... ...... ............. ... . ..... ................. .... ..... . .... ..... ..... ................. ..... .......... .13 ................ ........... iL 11, ... .... .......... 3 DEMOLITION GENERAL NOTES 1. CONTRACTOR SHALL INSPECT EXISTING LIGHTING FIXTURES WHICH ARE TO REMAIN AND NOTIFY KASH N KARRY PROJECT REPRESENTATIVE OF ANY REPAIRS INEEDED OR OF ANY NON-FUNCTIONING DEVICES. 2. ALL EXISTING CIRCUITS INDICATED TO RECEIVE ADDITIONAL LOAD SHALL BE TESTED WITH AN APPROPRIATE VOLT METER TO DETERMINE THE VOLTAGE DROP ON THE CIRCUIT. IF THE VOLTAGE DROP EXCEEDS 3x THE CIRCUIT SHALL REMAIN AS IS AND THE ADDED LOAD WILL BE SERVED FROM ANOTHER SOURCE, CONTACT ARCHITECT/ENGINZER FOR DIRECTION, 3. DEMOLITION SHALL BE CLOSELY COORDINATED WITH THE KASH N KARRY PROJECT REPRESENTATIVE AND THE STORE MANAGER BEFORE COMMENCING WORK IN ANY AREA. 4. CONTRACTOR SHALL COORDINATE WITH THE KASH N KARRY PROJECT REPRESENTATIVE FOR THE DISPOSITION OF ALL EXISTING EQUIPMENT BEING REMOVED PRIOR TO REMOVING ANY EQUIPMENT. 5. ALL LAMPS AND FIXTURES NOT TURNED OVER TO OWNER SHALL. BE PROPERLY DISPOSED OF BY THE CONTRACTOR AT THEIR OWN EXPENSE IN A PROPER AND ENVIRONMENTALLY SAFE METHOD. 6. THE INTENT OF THIS PLAN IS TO INDICATE THE GENERAL SCOPE OF THE ELECTRICAL DEMOLITION WORK. CONTRACTOR SHALL COORDINATE WITH G.C. ON SITE FOR ACTUAL SCOPE OF DEMOLITION WORK REQUIRED IN ALL RENOVATED AREAS AND COMPLY ACCORDINGLY. CONTRACTOR SHALL SATISFY THEMSELVES WITH THE INFORMATION SHOWN ON THESE ELECTRICAL PLANS AND CONTACT ENGINEER/ ARCHITECT FOR ANY QUESTION HE OR SHE MAY HAVE PRIOR TO BID. SUBMISSION OF A BID WILL BE EVIDENCE THAT THE CONTRACTOR HAS FULL UNDERSTANDING OF HIS /HER SCOPE OF WORK AND THE CONSTRUCTION DOCUMENTS, 7. CONTRACTOR SHALL IN HIS BID, ALLOW FOR CORRECTION OF ANY CODE VIOLATIONS THAT COULD BE IDENTIFY DURING A VISUAL INSPECTION. 8. MAINTAIN CONTINUITY OF EXISTING CIRCUITING REMAINING ACTIVE AFFECTED BY RENOVATION WORK. ALL OBSOLETE WIRING, CONDUITS, JUNCTION BOXES, ETC. SHALL BE REMOVED BACK To SOURCE UNLESS OTHERVASE NOTED. 9. SHALL EXISTINGHAVE FIXTGUARDSURES BEIANDNG RCAGESETROFITTED RENST I LLED WITH LAMPS THAT HAVE TUBE GUARDS OR ORE CAGES , (TYPICAL FOR WALLWASH FIXTURES) 91.-111111111 q SCALE 3/32J 1' 011 I — GENERAL LIGHT FIXTURE -RETROFIT NOTE: CONTRACTOR SHALL FIELD VERIFY EXISTING FIXTURES' TYPE, MANUFACTURER, ETC. AND PROVIDE ALL COMPONENTS NECESSARY TO RETROFIT EXISTING FIXTURES SHOWN IN LIGHTING PLAN NOTES WITH ELECTRONIC BALLASTS AND DOUBLE ROW T8 SP35 LAMPS. (TYPICAL FOR DELI/BAKERY, U,O,N,) w TRUE NORTH AN 'Af PLAN NORTH LIGHTING PLAN NOTES D EXISTING SURFACE MOUNTED MOUNTED LIGHT FIXTURES TO BE DISCONNECTED AND REMOVED. UTILIZE EXISTING CIRCUITS AND tE CONTROL TO WIRE NEW FIXTURES. SEE NEW LIGHTING PLAN, DRAWING E-1. M DISCONNECT, REMOVE, AND TURN OVER TO OWNER, OR 0 DISPOSE OF EXISTING STORE FRONT SIGNAGE AND FLOOD LIGHTS AS DIRECTED BY KASH N KARRY REPRESENTATIVE. EXISTING CIRCUITIN( L AND CONTROL TO REMAIN FOR CONNECTION TO NEW SIGNAGE. SEE NEW LIGHTING PLAN, DRAWING E-1. TYPICAL (IN SALES AREA) EXISTING SURFACE—MOUNTED T FLUORESCENT FIXTURE WITH (2) 8' T12 OR (1) 8- T8 LAMPS IN EACH TYP TO BE RETROFITTED. REMOVE EXISTING LAMPS, LAMP SOCKETS AND I BALLAST. PROVIDE NEW (2) 8' T8 SP35 LAMPS, SOCKETS AND NEW 0 ELECTRONIC BALLASTS WITH <207o THD. COORDINATE LENGTH OF FIXTURES AND NUMBER WITH FLOOR PLAN. CONTRACTOR SHALL VERIFY N EXISTING FIXTURE TYPES ON SITE PRIOR TO BID. REFER TO ALTERNATE BELOW. 04 TYPICAL EXISTING CEILING SURFACE—MOUNTED FLUORESCENT LIGHT FIXTURE WITH (1) 8' T12 LAMP EACH AND WALL WASH REFLECTOR TO BE DISCONNECTED, RETROFITTED, AND REMOUNTED ON TOP OF CASE FACING UPWARD, WITH REFLECTOR ORIENTATED TO WALL WASH. UTILIZE EXISTING CIRCUITS AND CONTROL TO WIRE FIXTURES AT NEW LOCATION, REMOVE EXISTING LAMPS, LAMP SOCKETS AND BALLAST. PROVIDE NEW 8' T8 I ig SP35 LAMPS, SOCKETS WITH ELECTRONIC BALLASTS WITH <20% THD. COORDINATE LENGTH OF FIXTURES AND NUMBER WITH FLOOR PLAN, EXISTING FLUORESCENT STRIP FIXTURE WITH (2) 8' 1112 LAMPS T EACH TO REMAIN AND BE RETROFITTED, REMOVE EXISTING LAMPS, SOCKETS AND BALLAST PROVIDE NEW (2) 8' T8 SP35 LAMPS, SOCKETS AND NEW ELECTRONIC BALLASTS WITH <20% THD. T I I COORDINATE LENGTH OF FIXTURES AND NUMBER WITH FLOOR PIJI CONTRACTOR SHALL VERIFY EXISTING FIXTURE TYPES ON SITE PRIOR TO BID. T 01 EXISTING CEILING SURFACE—MOUNTED FLUORESCENT LIGHT FIXTURE WITH (1) T12 LAMP EACH AND WALL WASH (TYPI. REFLECTOR TO BE DISCONNECTED, RETROFITTED, CLEANED, AND REMOUNTED ON TOP OF MULTI—DECK MEAT CASES SUCH THAT REFLECTOR IS ORIENTATED TO WALL WASH. REMOVE EXISTING LAMPS, SOCKETS AND BALLAST. PROVIDE NEW 8' T8 S?35 LAMPS, SOCKETS WITH ELECTRONIC BALLASTS WITH <20% THD. UTILIZE CIRCUITS AND CONTROL TO WIRE FIXTURES AT NEW LOCATION. SEE NEW LIGHTING PLAN, DRAWING E-1. EXISTING EMERGENCY EXIT LIGHT FIXTURE WITH BATTERY BACKUP TO BE REPLACED. SEE GENERAL NOTE #8 THIS DRAWING, EXISTING EMERGENCY LIGHT FIXTURE WITH BATTERY BACKUP TO BE RELOCATED. SEE GENERAL NOTE #8 THIS DRAWING, TYPICAL SURFACE—MOUNTED FLUORESCENT FIXTURE WITH T12 LAMPS WIRED TO CIRCUIT INDICATED TO BE REMOVED UTILIZE EXISTING CIRCUITS TO WIRE NEW FIXTURES, SEE NEW LIGHTING PLAN, DRAWING E-1. EXISTING PENDANT METAL HALIDE FIXTURE TO BE REMOVED. REMOVE I/ (TYP. OFF 7) CIRCUITING BACK TO LAST ACTIVE FIXTURE OR ELECTRIC PANEL. J 11 EXISTING LIGHT FIXTURES AND CIRCUITS IN THIS AREA TO REMAIN, UNLESS OTHERWISE NOTED. EXISTING 2 x 4' FLUORESCENT FIXTURE WITH (4) 4' T12 LAMPS TO REMAIN. REMOVE EXISTING LAMPS, LAMP SOCKETS AND BALLASTS. PROVIDE NEW T8 SP35 LAMPS, SOCKETS AND NEW ELECTRONIC BALLASTS WITH <20% THD. i 13 EXISTING FIXTURE TO BE RELOCATED. EXTEND WIRING AND CONDUIT AS REQUIRED, SEE NEW LIGHTING PLAN, DRAWING (Typ'). E-1. REMOVE EXISTING LAMPS, LAMP SOCKETS AND BALLAST. PROVIDE NEW T8 SP35 LAMPS, SOCKETS AND NEW ELECTRONIC BALLASTS WITH <20% THD. II 4 II ALTERNATE #1 NOTE: CONTRACTOR SHALL PROVIDE AN ALTERNATE PRICE FOR SUPPLYING AND INSTALLING ING NEW -SYMMETRICAL SILVER REFLECTORS EQUAL TO LITHONIA CSMR—SSR FOR EACH SALES AREA FIXTURE. (2) PER 8' NXTURE, ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAL MUST BE BROUGHT TO THE ARCHITECT'S R('HITEC_rS ATTENTION FOR CLARIFICATION, RESOLUTION .- ' AND DIRECTION BEFORE PROCEEDING WITH THE WORK. 1. 0 0 D5 Z A FMEZ SCALE AN11I Flom"LA1`4 iE � 3/32Z= V-011 I N T E R N A T 10 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281 1�9290 le V ax81328IT2T2 F—Mail api@archifectureplus.com License #AAC001935 CHEIIAYEB & ASSOCIATES, INC. CONSULTINI, ENGINEERS -===z1 ncT� C,-=- 3702 AZEWME = — (w!) 876-1416 TAMPA, FL 33609 9977 (fax) 876-0913 MEV 1� A S d Air h n IN ISSLIE DATE : 09/0610" I -S -SUE. FOR PERM T *AS DATED ARCHITECTUREPLUS INTERINATC)NAL, IN( -'- A 0 .............. ........... ; .......................... ..................................................... ................. I ............. I ........ A ..................... ; ............................... REVISION LOG &Q,•��-•�i .................................. I ................. TO .�fr�AT 49 CUA -LY 'M1H TkE MWABLE WNWIM UUNG OMES ND Tri aW=1j&MF70=A'1 - VKH .8T 61+, STATUTE KASH NP KARRY NO. 1 0%9J-111 it ................ ................. ... U I ,SANF.0R.D,FL ..... ..... . I .. .... ......... PRWECT NAME W.GHTING ­ I .............................. PEMOPT.I.O.N ... PLAN ............. SHEET NAME PRO,ECTMAREP. 99419.011 .............. I ............ I ............. I ......... DRAWN BY. SKC/BA OEGI(ED BY: SC .......... ......... SCALE AS NOTED ................... ......... PLOT DATE 9/6/01 IISSM FOR aim E man D .......... ... I ..... ............. SHEET NUMBER U i 9 CONNECT TO FLORAL CASE /7 O I PB -40,42 j :j ............:.......................... ... I. GFIGFI GFI IC 4 1 • I�� L ......... . ,-, ❑ ..... 19 +54 1 I I I NTH BELDEN 3/4 CONDUIT WI I''``:. EX I #8761 RUN OVERHEAD ICAL) "�•.�: �....... ....•. ........................................... ' f .... ..................... 5 J - KDo {{� M .. I ........... ; .. I. t EMS CONTROL ZONE (TYPICAL) I I I } LC -19 2 ...............................................................................__.......... f; :; f,. — — — — — — ——,— — — — — —i —. ❑— -- — — — ............................... -.............................................. 5 I� J .......... ........................................................ 5 . i f' L C ........................................................................................... ;....... E'OATE ATM 11 ;Ex { 1 ....................................... I........................................................................................... I.................................................................. I ®� COIN STAR 10 38. I 4Fii4fFiS+ .•I II °•. SEE ENLARGED PLAN {: (ON ROOF) 1 I I I ON SHEET E-5 FOR RELOCATED FLY FAN 21 2 PB -3335,37 _................................................. .... t 36 ADDI110NAL WORK [Ex.................................................. ....... 1 -- t i ...................................•........................................................ :�"' MAR TCART t PA -38 EX 34 PA -40 . I I ...................................I................................................................................................................................................................................................ RB -26,28 I s :s PB -34,36,38 �• .r . - — 4.2 14WP PB -39 3 (TYPICAL) 2 A.F.F.�G " ® - - - - - -.� - r:•.. ......... ............................................... .......44.1 ... I ........ I., ............. I ........................... 4 . ., 40A I I i ,,�, �• �,.. ................................... i fir, t 34.: _ 3.7:: . EXISTING 3 VESTIBULE ---034 D-39,41 ................................................................................................................................................................................... IPA Pg PC—JB— r r•i 30/3/30 i1........................................................................................................,......,............ *• MDP SWEAT q_J 1 NEMA3R ?RISER I L......................................................................... . . �.. t 13 F �________® {1 EXISTING ` r.ELECTRICAL 3/4" CONDUIT WITH. BELDE�1. 15 I NEW ROOF TOP , .i :..............ROOM I �Q761 RUN OVERHEAD (TYPICAL) �'�' •' `= . �" ` �� I tt" IGONDENSING RACK G I r J MDP 23OOA —s. - - - - 3 17 ............. 3 ............................ . MDP I PB 21 23 � ' NEMA 3R .......,.... 'I TEL _ I z 14 �® NEW ROOF TOP I t 1CONDENSING RACK 'A'0 i �•� — 2 ........................................................................................ MDP' 61/3/40.......................................................NEMA 313 ... : 41 I i 1 NEW ROOF TOP<I I :: ... 2.5 1 CONDENSING RACK B I ::::l ®' I I ,. r:2 1 :'r' ..4. li • . 0 20 I I l i I ,p11i "sc ' EXIST iWI 3/4" CONDUIT UNDERSLAB5 WITH BELDEN #8761'. I { k } Il ONUT CASE PB-3� :::: 02 15 I I I LC -14 F2 I / I 10 J 12 ,..... ......................................... I ...................... .................. I .................... C I ............................................................. ........................... is f. ........... . .....r...........................,....................... ........................ ....................... ... ............. ....... ................ .. :.I......... I•t•• - I' 1• 1 „ L)• .. PB18,1O,12 (TYP. OF 4) I ' I 12 PB -411 .......................... EXISTINGFIRE ALARM:a.................... .......................................................................... L...... .. ' PANEL. SEE FIRE ALARM SYSTEM NOTE .... i- � - op - SEE ENLARGED PLAN I I✓. ON SHEET E--/ FOR ADDITIONAL WORK A I W. W:H: sal 16 18 >ni _.-. 0 T, � D x SCALE LOOP LEGEND c � n 2"x4" WATERPROOF JUNCTION BOX 4'-0" A.F.F. WITHOUT COVER. LEAVE 15'-0" OF BELDEN #8761 1 m A SLACK FROM SEAFOOD SCALE. MAKEUP BY OTHERS. 0 2"x4" WATERPROOF JUNC11ON BOX 4'-0" A.F.F. WITHOUT COVER. LEAVE 15-0" OF BELDEN #8761 SLACK FROM MEAT SCALE MAKEUP BY OTHERS, 3 4"x4" WATERPROOF JUNCTION BOX MOUNTED ON MEAT PREP CEILING WITH THE 3/4" CONDUITS STUBBED DOWN 1" BELOW CEILING. I€AVE 15'-0" OF BELDEN #8761 (FROM OFFICE) HANGING FROM ONE CONDUIT AND 15'-0" OF #8761 (TO SEAFOOD SCALE HANGING FROM THE OTHER CONDUIT. ALL MAKEUP TO BE BY OTHERS. 2"x4" JUNCTION BOX MOUNTED 3'-0" A.F.F. IN OFFICE WITH 4—WIRE PHIONE JACK (VERIFY). 15-0" OF BELDEN #8761 SHALL BE LEFT FROM EACH DELI SCALE RUN AND FROM MEAT PREP. CONNECTION BETWEEN OUTLET AND HOST TO BE DONE BY OTHERS. 5 2`'x4" WATERPROOF JUNCTION BOX FLOOR MOUNTED. LEAVE: 15-0" OF BELDEN #8761 SLACK. MAKEUP BY OTHERS. COORDINATE -EXACT ROUTING IN FIELD WITH KASH IN KARRY CONSTRUCTION MANAGER AND CONSTRUCTION DOUMENTS. 2"x4" WATERPROOF JUNCTION BOX STUBBED UP AT REFRIGERATED CASE LEAVE 15.0" OF BELDEN #8761 SLACK FOR MAKEUP BY OTHERS. COORDINATE EXACT ROUTING IN FIELD WITH KASH N KARRY CONSTRUCTION MANAGER AND CONSTRUCTION DOCUMENTS. EXISTING E.C,P. F_ a 6) y Kx M >n 0 �. C) CD � x r z_ 0 m c asx Z.]►d1►1 SCALE MEZZA'NUNE PLA' NoZ 3/32"=1'-0" TRUE PLAN NORTH NORTH . 1 PROVIDE WEATHERPROOF 3P -30A UNFUSED DISCONNECT SWITCH, EQUAL TO "HUBBELL" MODEL #HBLDS3, MOUNTED 60 A.F.F. AND SEALTTTE CONNECTION TO STEAMER. 2 JUNCTION BOX FOR AIR CURTAIN. FLY FAN). COORDINA7 E FINAL LOCATION AND VOLTAGE WITH EQUIPMENT SUPPLIER. THE MECHANICAL CONTRACTOR o SHALL SUPPLY THE FLY FANS, FLY FAN MOUNTING BRACKETS, AND MICRO— SWITCHES. THE ELECTRICAL CONTRACTOR SHALL INSTALL AND WIRE THE MICRO—SWITCH FOR FLY FAN CONTROL, 3 ELECTRICAL CONTRACTOR SHALL EXTEND EXISTING WIRING AND CONDUIT (3#8, 1#8 E.G. IN 3/4"C) SERVING RELOCATED GRINDER/MIXER AND REINSTALL EXISTING TwSTLOCK PLUG AND RECEPTACLE ASSEMBLY AT NEW LOCATION. PROVIDE NEW JUNCTION BOXES AS REQUIRED. 4 REFER TO SCALE LOOP LEGEND ARID SCOPE OF WORKS ON THIS SHEET FOR EXTENT OF WORK REGARDING SCALE LOOP CABLING AND CONDUIT. L! 50 MOUNT JUNCTION BOX ABOVE CEILING AND WIRE TO INDICATED CIRCUIT FOR SIGNAGE LIGHTING. PROVIDE MOTOR -RATED SWITCH WITHIN SIGHT PER N.E.C. REQUIREMENTS. PROVIDE CONDUIT DROP TO SIGNAt3E WHERE SUSPENDED. 6 ELECTRICAL CONTRACTOR SHALL REPLACE FIRST RECEPTACLE FOR EACH PRODUCE CIRCUIT WITH GROUND FAULT INTERRUPTING TYPE AND PROVIDE NEW "WEATHERPROOF IN USE'' TYPE COVER. MAINTAIN CONTINUITY TO ALL EXISTING RECEPTACLES ON CIRCUITS. 7 ELECTRICAL CONTRACTOR SHALL PROVIDE CONNECTION TO FLOOR MOUNTED JUNCTION BOX WITH (2) NEMA5-20R RECEPTACLES FROM POWERPOLE. VERIFY ISLAND MERCHANDISER POWER REQUIREMENTS AND PLUG CONFIGURATION PRIOR TO ROUGH -IN. COORDINATE ROUTING WITH RECEPTACLE LOCATION WITH KASH N KARRY CONSTRUCTION MANAGER. 10 8 RUN 2 1OE.G. IN 3/4"C TO P EL # 1 #AN SHOWN VIA NEW CONTROL RELAY AND CONNECT TO EXISTING SPARE 1P -20A C/B. 9 ELECTRICAL CONTRACTOR SHALL EXTEND EXISTING WIRING AND CONDUIT (2#10, 1#10 E.G, IN 3/4"C) SERVING RELOCATED ICE: MAKER AND REINSTALL EXISTING DISCONNECT SWITCH AT NEW LOCATION. PROVIDE NEW JUNCTION BOXES AS REQUIRED. 10 ELECTRICAL CONTRACTOR SHALL FROMDE RECEPTACLE AND CIRCUIT FOR COIN STAR. RUN (1) 4 PAIR 24 AWG PLENUM PHONE CABLE BACK TO TELEPHONE BOARD IN ELECTRIC ROOM, COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER, 11 ELECTRICAL CONTRACTOR SHALL PROVIDE RECEPTACLE AND CIRCUIT FOR ATM. RUN (1) 4 PAIR CAT 5 DATA CABLE (PLENUM RATED) BACK TO TELEPHONE BOARD IN ELECTRIC ROOM. COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER. 12 PROVIDE CONNECTION TO HAND DRYER, VERIFY EXACT LOCATION AND MOUNTING HEIGHT WITH KASH N KARRY CONSTRUCTION MANAGER PRIOR TO ROUGH -IN. 13 EXISTING CONDENSER RACK TO BE REPLACED WITH NEW. RECONNECT EXISTING CIRCUITING TO NEW DISCONNECT SWITCH. REI IR TO RISER ON SHEET E-4 FOR NEW CIRCUIT BREAKER IN MDP. COORDINATE WITH REFRIGERATION CONTRACTOR. 14 EXISTING CONDENSER RACK TO BE REPLACED WITH NEW. RECONNECT EXISTING CIRCUITING TO NEW DISCONNECT SWITCH. COORDINATE WITH REFRIGERATION CONRTRACTOR. 15 ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL BLANK POWER POLE EQUAL TO WIREMOLD 25DTP-412 FROM HUNG CEILING DOWN TO DISPLAY CASE. PROVIDE ALL MOUNTING HARDWARE AND RECEPTACLES AS REQUIRED. NEW 16 hEA! ENERG Y MANAGEMENT SYSTEM CONTACTOR SCREEN 18 x18 x6 CABINET TO BE PURCHASED FROM McNAMARA & CO. BY THE ELECTRICAL CONTRACTOR. PHONE 1-888-996-2220. SUBMIT DRAWINGS TO McNAMARA FOR CONTACTORS REQUIRED, RUN (10) #14 AWG STRANDED CONDUCTORS IN 3/4"C FROM EACH NEW CONTACTOR SCREEN CABINET TO ECP IN MEZZANINE FOR CONTROL. COORDINATE ALL WORK WITH KASH N KARRY CONSTRUCTION MANAGER PRIOR TO BID. 17 SEE PLAN NOTE #7 ON SHEET E-5 FOR NEW CUSTOMER SERVICE TELEPHONE CABLES. 18 EXISTING COMPRESSOR RACK TO BE REWIRED WITH NEW MAIN BREAKER. REFER TO EXISTING POWER RISER ON SHEET E-4, FOR NEW WIRING TO PANEL 'MDP' AND NEW CIRCUIT BREAKER. COORDINATE WITH REFRIGERATION CONTRACTOR. 13 RELOCATE EXISTING INTERCOM AND TELEPHONE RECEPTACLES TO NEW DESK LOCATION. EXTEND EXISTING WIRING AND CONDUIT AS REQUIRED. 20 ROUTE 3/4" CONDUIT WITH (1) 4 PAIR 24 AWG CABLE BACK TO TELEPHONE BOARD FROM TELEPHONE WALL RECEPTACLE. ROUTE 3/4" CONDUIT WITH PULLSTRING FROM INTERCOM W C ALL RECEPTACLE AND STUB UP ABOVE CEILING TO BAR JOIST HEIGHT. MOUNT RECEPTACLES 18" APART AT 54" A.F.F., U.N.O. COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER. 21 ELECTRICAL CONTRACTOR SHALL DISCONNECT AND RELOCATE EXISTING DISCONNECT SWITCH AND EXTEND CIRCUITING TO NEW LOCATION OF RELOCATED FLY FAN. PROVIDE NEN! WIRING FOR MICRO—SWITCH AS REQUIRED. WIRE SIZE NOTE (TYPICAL OF ALL SHEETS) WHERE WIRE SIZE IS SHOWN IN PANEL SCHEDULE OR ON FLOOR PLANS, THE SAME WIRE SIZE, AS A MINIMUM, SHALL BE CARRIED THROUGH OUT THE CIRCUIT. `1 rlr- . Fir, /AUMr,%1VI ��,`�'�:i5�4i,�����','�"_�,s,f�,�,ra=��s'--..,1"i#ti'�u(�t fir::<2�f� ,,.,-it..�,..exp.nv�'�•ak'�:r?r'5�,���,�s'�irP.r„�cx�l�.�d.tYr'�.., .. TSE ?FRE ALARM! SYSTEfvIM IS kIS, TNG AI IDS N}OFwAt3DITIONALlSQUAREFOOTAGE .IIS,3BEINGz AaDED TO TFfE EXISTING STRUCTURE, WHICH IS,fULLY SPRINKLERED. Alt LN90DIFIOATIONS REQUIRED_ B Y . KASht -sN KARRY (3F2 LCICAL FIRI OFFICIALS SHALL BE IIVGORPORATED INTO THE EXISTING SYSTE 4 UNDER A SEPERATE r�®IYTRAItT •fir exf y�la 4�h5{{µ{ii x . ,f 3�Tr � ! t s{i 5s �"�3r �, byk + . �.., ..” r x .: 1 <�.. $' F S SCALE LOOP SYSTEM SCOPE OF WORK NOTES: ALL DEVICES, CONDUIT AND CABLING SHOWN FOR THE SCALE LOOP IS SHOWN AS NEW. 'THE EIEC MCAL CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS AND REUSE EXISTING SCALE LOOP WHERE POSSIBLE. THE ELECTRICAL CONTRACTOR SHALL COORDINATE WITH KASH N KARRY'S CONSTRUCTION MANAGER PRIOR TO BID FOR EXTENT OF WORK ASSOCIATED WITH NEW SCALE LOOP. PROVIDE PHONE JACKS AT EACH SCALE LOCATION IF REQUIRED BY KASH N KARRY. fa 0 I N T E R N A TI O N A L 2709 Rc sky Point Drive, Suite 201 Tampa, 7 Floridaa 338 Tel 813281-0, 9 Fax 813281.9292 E—Mail api@architectureplus.com License #AAC001935 C13E'IIAYEB & ASSOCIATES, INC. CONSULTING ENGINEERS -CS- T 3742 AZEELE ST (813) 876-1415 TAAiPA FL 33609 9977 (.faz) 876-0913 mash n" ano MW M AF ll y ISSLE DATE Q /06/01 ISSUE FOR PERMT DATED ARCHITECTLJREPLUS INTEFINATIONAL, INC, A ........... ................. AA............. I ........ ............. ........ ........ ....... A. .................... ... I REVISION LOG TO ME r"C•ST Cr RE CQOMEDGE Cr Tic A "affEm A"W .'moi WD llvlia ND $FK"W4S CMILY WITH TFE APKrAE.E h"" 6t"M CCOB3 AAD THE APP"RE .Pd WE SAFETY STAN AS C£T� N ACGOHCE WTH CHEM 6�3 AAD M a- 1w *w SkRfA4t3dlu TO TI -E fi.Cf✓Q4 STATUTE ' ra .......®........................ PPOJECT NAME ................... SHEET NAME PRMCT NUM.Ft 9949.01 DRAWN BY: SKC/B,ABY. SC SCALE. AS NOTED OT DATE 9/6/01 MM FOR- ............................................ 2 ............ I ...................... I ................. SHEET NUMBER SCALE 3/321=1'-0° DEMOLITION L NOTES 1. CONTRACTOR SHALL INSPECT EXISTING EQUIPMENT WHICH IS TO REMAIN AND NOTIFY KASH N KARRY PROJECT REPRESENTATIVE OF ANY REPAIRS NEEDED OR OF ANY NON–FUNCTIONING DEVICES. 2. ALL EXISTING CIRCUITS INDICATED TO RECEIVE ADDITIONAL LOAD SHALL BE TESTED WITH AN APPROPRIATE VOLT METER TO DETERMINE THE VOLTAGE DROP ON THE CIRCUIT. IF THE VOLTAGE DROP EXCEEDS 3X THE CIRCUIT SHALL REMAIN AS IS AND THE ADDED LOAD WILL BE SERVED FROM ANOTHER SOURCE. CONTACT ARCHITECT/ENGINEER FOR DIRECTION. 3, DEMOLITION SHALL BE CLOSELY COORDINATED WITH THE KASH N KARRY PROJECT REPRESENTATIVE AND THE STORE MANAGER BEFORE COMMENCING WORK IN ANY AREA. 4. CONTRACTOR SHALL COORDINATE WITH THE KASH N KARRY PROJECT REPRESENTATIVE FOR THE DISPOSITION OF ALL EXISTING EQUIPMENT BEING REMOVED PRIOR TO REMOVING ANY EQUIPMENT. 5. THE INTENT OF THIS PLAN IS TO INDICATE THE GENERAL SCOPE OF THE ELECTRICAL DEMOLITION WORK. CONTRACTOR SHALL COORDINATE WITH G.C. ON SITE FOR ACTUAL SCOPE OF DEMOLITION WORK,REQUIRED IN ALL RENOVATED AREAS AND COMPLY ACCORDINGLY. CONTRACTOR SHALL SATISFY THEMSELVES WITH THE INFORMATION SHOWN ON THESE ELECTRICAL PLANS AND CONTACT ENGINEER/ ARCHITECT FOR ANY QUESTION HE OR SHE MAY HAVE PRIOR TO BID. SUBMISSION OF A BID WILL BE EVIDENCE THAT THE CONTRACTOR HAS FULL UNDERSTANDING OF HIS/HER SCOPE OF WORK AND THE CONSTRUCTION DOCUMENTS. 6. CONTRACTOR SHALL IN HIS BID, ALLOW FOR CORRECTION OF ANY CODE VIOLATIONS THAT COULD BE IDENTIFY DURING A VISUAL INSPECTION. 7, MAINTAIN CONTINUITY OF EXISTING CIRCUITING REMAINING ACTIVE AFFECTED BY RENOVATION WORK. ALL OIJSOLEt WIRING, CONDUITS, JUNCI1I4DN BOXES, ETC. SHALL BE REMOVED BACK 10 SOURCE UNLESS OTHERWISE NOTED. 8. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER AND RELOCATE ANY MOTION SENSORS, CAMERAS AND MISC. SECURITY EQUIPMENT AS DIRECTED IN FIELD, ELECTRICAL DEMOLITION PLAN � 1 ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAL MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION, RESOLUTION AND DIRECTION BEFORE PROCEEDING WITH THE WORK. ZJ Drp D4 1 D.4 �Da 3.i a L I'D TRUE NORTH PLAN NORTH DEIVIOLITION �( EXISTING #2 UNDERFLOOR DUCT FOR CASH STANDS COMMUNICATION CABLING TO BE ABANDONED. PROVIDE PLUGS OR BLANK PLATES FOR ALL UNDERFLOOR DUCT OPENINGS BECOMING OBSOLETE DUE TO NEW CASH STAND LOCATIONS. AL WORK INVOLVING REMOVAL OF EXISTING CASH REGISTER COMMUNICATION AND INTERCOM WIRING TO BE COORDINATED WITH KASH N KARRY PRIOR TO DISCONNECTION OF EXISTING CABLING. REFER TO SHEET E-5 FOR ROUTING OF NEW CABLING. �2 EXISTING #4 UNDERFLOOR DUCT FOR CASH STANDS POWER 6 6 6 6 6 6 6 to .............. �\ �/ V -- ----- (% ................................................. REQUIRED. EXISTING WIRING TO BE REMOVED, COORDINATE WITH ••",°,,• :......:......:......:......:.....;......;.....:::. .•.. ; .,. : •:. : • .. ::. : '• ,. ... ._.. 8 POTATOES ................................. ....... 40 NZ�l51 PRUU:IGE 03 EXISTING POWER PANEL 'CR' FEEDING CASH STANDS TO REMAIN. EXISTING COMMUNICATIONS PANEL FEEDING CASH STANDS TO 10 80' LV5HI FROZEN FOOD TELEPHONE LINE FOR ATM. EXISTING REFRIGERATION CASE TO BE REPLACED WITH NEW. DISCONNECT CASE FROM EXISTING CIRCUIT, EXTEND EXISTING PRODUCE PREP, ROOM CIRCUITS AND CONDUITS TO WIRE NEW CASE. TO INCLUDE ANTI -SWEAT HEATER, FAN, LIGHTING, AND REFRIGERATION CONTROL CIRCUITS, IF APPLICABLE, COORDINATE WITH REFRIGERATION CONTRACTOR. 25 � 25 REPLACED WITH NEW. DISCONNECT EXISTING CIRCUIT. SEE NEW FLOOR PLANS FOR CIRCUITING OF NEW EQUIPMENT. SEE SHEET E' -2K AND E-7. EXISTING GRINDER TO BE RELOCATED. REMOVE EXISTING RECEPTACLE, WIRING AND CONDUIT TO FIRST CONCEALED 60' LV5H1 FROZEN FOOD JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF GRINDER. EXISTING TWIST -LOCK RECEPTACLE AND PLUG TO BE REUSED. SEE SHEET E-2. 0 EXISTING REFRIGERATED CASE TO BE REMOVED, DISCONNECT 6 6 . d0 CONTINUITY OF WIRING TO REFRIGERATED CASES TO REMAIN. ALL QBSOLE;'E WIRING TO BE REN40VED BACK TO SOURCE OR LAST ACTIVE DEVICE. .: . 6 DISCONNECT SW., WIRING AND CONDUIT TO FIRST CONCEALED JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF' ICE MAKER AND REINSTALL EXISTING DISCONNECT .......... o •:' SWITCH. SEE SHEET E-2. �6 , ti REMOVE EXISTING WIRING BACK TO PANEL. CONDUIT TO REMAIN FOR WIRING TO NEW EQUIPMENT. 2 6 I2 EXISTING RACK OVEN TO BE REPLACED WITH NEW. DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRE BACK 6 .•'''•�' TO SOURCE. 13 EXISTING SUPPLY AND EXHAUST FANS FOR HOOD TO BE CD 60` LY5N1 FRcJZEN FOQ� _: REMOVE EXISTING WIRING BACK TO PANEL. CONDUIT TO REMAIN FOR WIRING TO NEW EQUIPMENT. STORAGE FREEZER 15 DISCONNECT AND REMOVE RECEPTACLES OR EQUIPMENT SHOWN AND ASSOCIATED WIRING AND CONDUIT BACK TO SOURCE OR LAST ACTIVE RECEPTACLE. 16 EXISTING POWER POLES FOR COOLERS AT GONDOLAS TO BE PROD'U'CE COOLER' AND POWER POLES RELOCATED AS DIRECTED BY KASH N KARRY IN FIELD. SEE SHEET E=5 77 EXISTING REFRIGERATION CONDENSER RACK TO BE REPLACED DISCONNECT AND REMOVE DISCONNECT SWITCH. EXISTING POWER AND CONTROL WIRING TO REMAIN FOR RECONNEC11ON 62 GONDOLA ................................................................................. ........................... _ JVD:'' 18 EXISTING CONNECTIONS TO PROOFER TO BE REMOVED. DISCONNECT AND REMOVE WIRING BACK TO TO PANEL PROVIDE ,'•;26 Iq DISCONNECT AND REMOVE ALL OBSOLETE PLUGMOLD, CONDUIT AND WIRING ASSOCIATED WITH SENSORMATIC EQUIPMENT BEING RELOCATED. COORDINATE ALL WORK WITH KASH N KARRY : 1___ .......... ........... ......... ................... ........ ................................... .......... ......................... ........................................ .......... ____ _. FOR ADJACENT CASES TO REMAIN IN OPERATION. L .......... EXTENSION TO NEW REGISTER LOCATION. SEE SHEET E-5. a 22 EXISTING WIRING, CONDUIT AND RECEPTACLES FOR COOLERS TO BE REMOVED, ELECTRICAL CONTRACTOR SHALL PROVIDE NEW RECEPTACLES AT ALTERATE GONDOLA LOCATION AND CONNECT TO GONDOLA RECEPTACLE CIRCUITS. COORDINATE n EXACT LOCATION WITH KASH N KARRY CONSTRUCTION MANAGER. PROVIDE ADDITIONAL CIRCUITING AND POWER POLES IF REQUIRED. i _64: .. f a .... 06 CONQOLA..........................................................•................ ..................................•................ TO NEW WIRING AT LOCATION SHOWN ON SHEET E-7. 24 EXISTING TELEPHONE AND INTERCOM RECEPTACLES TO BE 2 ;: a SAGS -120 SAG3-120 z 3 i 1:::::::::::::::::::::::::::::........................................................................................ : �u ................�. ........ :i E TO BE REPL%CED. EXTEND EXISTING CONDUIT AND WIRING TO NEW UNIT INCLUDING CONTROL WIRING IF APPLICABLE, 2 205 C, ! i ...2.1.................................. ................................................. ......................... _----I 4 �0 EXTEND EXISTING CONDUIT AND WIRING TO NEW UNIT INCLUDING DOOR CONTACTS AND CONTROL WIRING. CONDENSATE HEAT TAPE o MEAT COOLER :Z4_ f 27 EXISTING REFRIGERATION COMPRESSOR RACK 'C' TO BE REWIRED < n DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING BACK TO PANEL 'MDP': 2g EXISTING FLY FAN TO BE RELOCATED. REMOVE EXISTING DISCONNECT SW., WIRING AND CONDUIT TO FIRST CONCEALED JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF FLY FAN AND REINSTALL EXISTING DISCONNECT 20 16.:::: ::::::::: ............ 74 CONDOLA (5 POWs) I ........................................................... ...... _ _.: TRAY COOLER �� IF B5 4'-4°x10'-I°x8'_4° H ............ ..... i ... .. o' E _ o•:i::...• F:4 ,f 25 I• :r, , . 2 a L ¢. ,MEAT ....................•.......................................................•....•......................,.... r__ 2, ................. ........................ ..........•..................................................................... --- :..:.. > I MA 12TG;ART __............................. .................................................................................... ........ ............. ............. ................................. ........... ___ ......... .............. ••tea PREP. ROOM V Ls SBNG�MATlC !� ELECTRIC 34'•-4°x22' ©" MEAT FREEZER (TYP.) N LER EYE T C r-' T-q"x7-gox3"-8"H. i I -_.....I$1 .................• --- 1 / I .............................:.... � � J VESTIBULE i 24' - _ � ~iClJ 2� /` 1 i JANTOR 8 -4'x7'-2 LD 26 r - : �,/ MEAT U, YP. ) :........ �� 5 STORAGE c7 _..... : .................... •. I I off r_ L.t I 21° � " I6 PB PC EMCC r�,* PA �: L._...................................................................................................... .. ........... .................................................... .............................. --- = .... m: _. GROOERY r: .................... ELECTRICAL ..... i :... �REC©PT , & ? C ROOM. .......:..................... .......... ,,..,.,..,.....,...............,...,.,..,.,,.,,,,...,........................... _ .. --= s,oRA�E o .........•. 0 3`-10°x16' 10" r__ I ; 24 I TYP. ) a I I� „ � TO v i :_....: __ ........................... 27" 66' GONDOLA (3 ROW51 ....................... - --� i I - n4 ^ GONDEN5ERC.` I 17 .......................... 6...............................................................................................................•..................................................__ — � s– L__®®__m_®__.J -------- - 7 oFF� E c —� • :CONI?EN SER A llif El till . _.__. .: ._._........................ •....... :: :: ,I ...... ... , i ,O OQ M E :..... ; �+----_-�_m_ :]i I 27' �-- ............................. �__- J DaLI/ � u i - BAKERY o COOLER CONDENSER "D" 1-417) - 25 J `-' L— m= o � RAIRY COOLER 20'3"x2O'3''x8'4" H, t, .._.T ........ r _ I . ...................... I 24 .. _ Y,.: l tTERV -WNW ROOM. YAA3-195 6 i Yi __ . 26' CGNDOLA _......................:•............................... ........................................STORAGE ;................................. ;......................::........... 40 961 BEER 1�2D2 �..........DELI/BAKERY ROOM :• n 1 27'a 23 I 27' __ - .. f :.:: XAG5-180 I :....: WOMEN"S MEN"S <` ROOM ROOM 5'-6" LDICI 5'-6" LOlrl_.....:......................:..•..;......._.....:.....,......,:.....;...... " 22 �0' AREA 7RY AR ..... DELI/BAKE i �/DAIRY PROMO .. """""""" AIRY PROMO :.• :..••:.••:••'..•:'.••:.•:.• .. 40 IVSHI IG ECR EAM Lo i w ICE CREAM FZR i .. i 1. j � jj l3 jtl. ................w LI......... ............... DELI /BAKERY o m 0 FREEZER ' SECIJRITf RM. CORRIDOR No.2 ': Jt(NK l2' D6t En''S S4 U61 UA4 Y ..... .... 6' L5FAi - FROZEN DELI 26 —v .� DISPLAY 8......................................................................................... F1 6 6 ..... Ar� 0 2 s i SCALE 3/321=1'-0° DEMOLITION L NOTES 1. CONTRACTOR SHALL INSPECT EXISTING EQUIPMENT WHICH IS TO REMAIN AND NOTIFY KASH N KARRY PROJECT REPRESENTATIVE OF ANY REPAIRS NEEDED OR OF ANY NON–FUNCTIONING DEVICES. 2. ALL EXISTING CIRCUITS INDICATED TO RECEIVE ADDITIONAL LOAD SHALL BE TESTED WITH AN APPROPRIATE VOLT METER TO DETERMINE THE VOLTAGE DROP ON THE CIRCUIT. IF THE VOLTAGE DROP EXCEEDS 3X THE CIRCUIT SHALL REMAIN AS IS AND THE ADDED LOAD WILL BE SERVED FROM ANOTHER SOURCE. CONTACT ARCHITECT/ENGINEER FOR DIRECTION. 3, DEMOLITION SHALL BE CLOSELY COORDINATED WITH THE KASH N KARRY PROJECT REPRESENTATIVE AND THE STORE MANAGER BEFORE COMMENCING WORK IN ANY AREA. 4. CONTRACTOR SHALL COORDINATE WITH THE KASH N KARRY PROJECT REPRESENTATIVE FOR THE DISPOSITION OF ALL EXISTING EQUIPMENT BEING REMOVED PRIOR TO REMOVING ANY EQUIPMENT. 5. THE INTENT OF THIS PLAN IS TO INDICATE THE GENERAL SCOPE OF THE ELECTRICAL DEMOLITION WORK. CONTRACTOR SHALL COORDINATE WITH G.C. ON SITE FOR ACTUAL SCOPE OF DEMOLITION WORK,REQUIRED IN ALL RENOVATED AREAS AND COMPLY ACCORDINGLY. CONTRACTOR SHALL SATISFY THEMSELVES WITH THE INFORMATION SHOWN ON THESE ELECTRICAL PLANS AND CONTACT ENGINEER/ ARCHITECT FOR ANY QUESTION HE OR SHE MAY HAVE PRIOR TO BID. SUBMISSION OF A BID WILL BE EVIDENCE THAT THE CONTRACTOR HAS FULL UNDERSTANDING OF HIS/HER SCOPE OF WORK AND THE CONSTRUCTION DOCUMENTS. 6. CONTRACTOR SHALL IN HIS BID, ALLOW FOR CORRECTION OF ANY CODE VIOLATIONS THAT COULD BE IDENTIFY DURING A VISUAL INSPECTION. 7, MAINTAIN CONTINUITY OF EXISTING CIRCUITING REMAINING ACTIVE AFFECTED BY RENOVATION WORK. ALL OIJSOLEt WIRING, CONDUITS, JUNCI1I4DN BOXES, ETC. SHALL BE REMOVED BACK 10 SOURCE UNLESS OTHERWISE NOTED. 8. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER AND RELOCATE ANY MOTION SENSORS, CAMERAS AND MISC. SECURITY EQUIPMENT AS DIRECTED IN FIELD, ELECTRICAL DEMOLITION PLAN � 1 ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAL MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION, RESOLUTION AND DIRECTION BEFORE PROCEEDING WITH THE WORK. ZJ Drp D4 1 D.4 �Da 3.i a L I'D TRUE NORTH PLAN NORTH DEIVIOLITION �( EXISTING #2 UNDERFLOOR DUCT FOR CASH STANDS COMMUNICATION CABLING TO BE ABANDONED. PROVIDE PLUGS OR BLANK PLATES FOR ALL UNDERFLOOR DUCT OPENINGS BECOMING OBSOLETE DUE TO NEW CASH STAND LOCATIONS. AL WORK INVOLVING REMOVAL OF EXISTING CASH REGISTER COMMUNICATION AND INTERCOM WIRING TO BE COORDINATED WITH KASH N KARRY PRIOR TO DISCONNECTION OF EXISTING CABLING. REFER TO SHEET E-5 FOR ROUTING OF NEW CABLING. �2 EXISTING #4 UNDERFLOOR DUCT FOR CASH STANDS POWER WIRING TO BE ABANDONED. PROVIDE PLUGS OR BLANK PLATES FOR ALL UNDERFLOOR DUCT OPENINGS NO LONGER IN USE. REMOVE OBSOLETE RECEPTACLES AND CUT CONDUIT AS REQUIRED. EXISTING WIRING TO BE REMOVED, COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER. REFER TO SHEET E-5 FOR NEW CIRCUITING. N 03 EXISTING POWER PANEL 'CR' FEEDING CASH STANDS TO REMAIN. EXISTING COMMUNICATIONS PANEL FEEDING CASH STANDS TO REMAIN. �5 DISCONNECT AND REMOVE EXISTING RECEPTACLE AND TELEPHONE LINE FOR ATM. EXISTING REFRIGERATION CASE TO BE REPLACED WITH NEW. DISCONNECT CASE FROM EXISTING CIRCUIT, EXTEND EXISTING CIRCUITS AND CONDUITS TO WIRE NEW CASE. TO INCLUDE ANTI -SWEAT HEATER, FAN, LIGHTING, AND REFRIGERATION CONTROL CIRCUITS, IF APPLICABLE, COORDINATE WITH REFRIGERATION CONTRACTOR. i-'_.! EXISTING DELI/BAKERY EQUIPMENT TO BE REMOVED AND REPLACED WITH NEW. DISCONNECT EXISTING CIRCUIT. SEE NEW FLOOR PLANS FOR CIRCUITING OF NEW EQUIPMENT. SEE SHEET E' -2K AND E-7. EXISTING GRINDER TO BE RELOCATED. REMOVE EXISTING RECEPTACLE, WIRING AND CONDUIT TO FIRST CONCEALED JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF GRINDER. EXISTING TWIST -LOCK RECEPTACLE AND PLUG TO BE REUSED. SEE SHEET E-2. 0 EXISTING REFRIGERATED CASE TO BE REMOVED, DISCONNECT CONNECT EQUIPMENT FROM EXISTING CIRCUIT, CUT CONDUIT BELOW FLOOR, CAP, AND PATCH AS REQUIRED. MAINTAIN CONTINUITY OF WIRING TO REFRIGERATED CASES TO REMAIN. ALL QBSOLE;'E WIRING TO BE REN40VED BACK TO SOURCE OR LAST ACTIVE DEVICE. IO EXISTING ICE MACHINE TO BE RELOCATED. REMOVE EXISTING DISCONNECT SW., WIRING AND CONDUIT TO FIRST CONCEALED JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF' ICE MAKER AND REINSTALL EXISTING DISCONNECT SWITCH. SEE SHEET E-2. II EXISTING HOT CASE TO BE REMOVED. DISCONNECT AND REMOVE EXISTING WIRING BACK TO PANEL. CONDUIT TO REMAIN FOR WIRING TO NEW EQUIPMENT. I2 EXISTING RACK OVEN TO BE REPLACED WITH NEW. DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRE BACK TO SOURCE. 13 EXISTING SUPPLY AND EXHAUST FANS FOR HOOD TO BE REMOVED. DISCONNECT AND REMOVE ALL SWITCHES, LIGHTS AND ASSOCIATES WIRING BACK TO SOURCE. 14 EXISTING BAR–B–QUE TO BE REMOVED. DISCONNECT AND REMOVE EXISTING WIRING BACK TO PANEL. CONDUIT TO REMAIN FOR WIRING TO NEW EQUIPMENT. 15 DISCONNECT AND REMOVE RECEPTACLES OR EQUIPMENT SHOWN AND ASSOCIATED WIRING AND CONDUIT BACK TO SOURCE OR LAST ACTIVE RECEPTACLE. 16 EXISTING POWER POLES FOR COOLERS AT GONDOLAS TO BE v i Ai i E' i REMOVED. E.,,l.�TING �!!RlRG TO REhrI�IP. AND B� EXTENDED AND POWER POLES RELOCATED AS DIRECTED BY KASH N KARRY IN FIELD. SEE SHEET E=5 77 EXISTING REFRIGERATION CONDENSER RACK TO BE REPLACED DISCONNECT AND REMOVE DISCONNECT SWITCH. EXISTING POWER AND CONTROL WIRING TO REMAIN FOR RECONNEC11ON TO NEW REFRIGERATION CONDENSER. 18 EXISTING CONNECTIONS TO PROOFER TO BE REMOVED. DISCONNECT AND REMOVE WIRING BACK TO TO PANEL PROVIDE FLUSH BLANK WAH PLATES AS REQUIRED. Iq DISCONNECT AND REMOVE ALL OBSOLETE PLUGMOLD, CONDUIT AND WIRING ASSOCIATED WITH SENSORMATIC EQUIPMENT BEING RELOCATED. COORDINATE ALL WORK WITH KASH N KARRY CONSTRUCTION MANAGER PRIOR TO DISCONNECTION, 20 EXISTING REFRIGERATION CASE TO BE REPLACED WITH NEW. DISCONNECT CASE FROM EXISTING CIRCUIT, REWORK CONTROLS FOR ADJACENT CASES TO REMAIN IN OPERATION. 2t EXISTING CASH REGISTER WIRING AND CABLE TO REMAIN FOR EXTENSION TO NEW REGISTER LOCATION. SEE SHEET E-5. 22 EXISTING WIRING, CONDUIT AND RECEPTACLES FOR COOLERS TO BE REMOVED, ELECTRICAL CONTRACTOR SHALL PROVIDE NEW RECEPTACLES AT ALTERATE GONDOLA LOCATION AND CONNECT TO GONDOLA RECEPTACLE CIRCUITS. COORDINATE EXACT LOCATION WITH KASH N KARRY CONSTRUCTION MANAGER. PROVIDE ADDITIONAL CIRCUITING AND POWER POLES IF REQUIRED. 23 EXISTING RECEPTACLE FOR MIXER TO BE RELOCATED. DISCONNECT AND REMOVE' WIRING BACK TO PANEL.. CONNECT RECEPTACLE TO NEW WIRING AT LOCATION SHOWN ON SHEET E-7. 24 EXISTING TELEPHONE AND INTERCOM RECEPTACLES TO BE RELOCATED TO NEW DESK LOCATION, SEE SHEET E-2. 25 EXISTING COOLER OR PREP AREA EVAPORATOR FAN COIL UNIT TO BE REPL%CED. EXTEND EXISTING CONDUIT AND WIRING TO NEW UNIT INCLUDING CONTROL WIRING IF APPLICABLE, COORDINATE WITH REFRIGERATION CONTRACTOR. 26 EXISTING FREEZER EVAPORATOR FAN COIL UNIT TO BE REPLACED. EXTEND EXISTING CONDUIT AND WIRING TO NEW UNIT INCLUDING DOOR CONTACTS AND CONTROL WIRING. CONDENSATE HEAT TAPE POWER TO REMAIN. COORDINATE WITH REFRIGERATION CONTRACTOR, 27 EXISTING REFRIGERATION COMPRESSOR RACK 'C' TO BE REWIRED DISCONNECT AND REMOVE EXISTING CONDUIT AND WIRING BACK TO PANEL 'MDP': 2g EXISTING FLY FAN TO BE RELOCATED. REMOVE EXISTING DISCONNECT SW., WIRING AND CONDUIT TO FIRST CONCEALED JUNCTION BOX, EXTEND CONDUIT AND WIRING TO NEW LOCATION OF FLY FAN AND REINSTALL EXISTING DISCONNECT SWITCH. SEE SHEET E-2. ARMIRTURPM I N T E R N A T 1 0 N A L 2709 Rocky Point Drive; Suite 201 Tampa, Florida 33007 Tel 813.281,9299 Fax 813281.9292 E—Mail api@architectureplus.com License #AAC001935 CHEHAYEB _.eft CONS>LTING ENGfNEERS 3702 AZF.E'LF ST. C�S (813) 876-1415 TAMPA, FL 33609 9977 (Jhz) 876-0913 mewn pri n K� a rr y ISSUE DATE: 09/06/01 IE FOR PERMIT CCAS DATED ARCHITECTUREPLUS INTERNATI)IAL, INC, A................................................. i ..................................................... ..................................................... O ..................................................... REVISION LOG TO TWE TE5T OF TOE *0&= OF rX Mid=L , AND =SM Ka ftf.143 $EU"TM CC&ftY VM TW AFRrAKE W"" UWjJC3 CODES nO TW Afi"EAE WAN FM SAFM 5fAt$ AS CUEMB..W N ACCOMAWE MM CWfUS 633"833 CF TFE 17 SIfffW/& 3 T0 71 -E FLCFM STATUTE ....................,.. fL. ........................ PPQMT NAME SHEET NAME PR CT NUMBEFt ® ®0? DRAWN BY: SKC/BA BY: SC SCALE: AS . PLOT DATE" 9/6/01 ISSIX FOR Lem 2D ................... I ........ -1 ...... 11 .............. SHEET NUMBER �, I PA -19 0 (AACK 'A' 0: PC -7,11,11 3 8 PB 2,4,6 3 8 PB -11,3 l 6 . ............... I-: . . . .......... ---------------- ................ ............... GD D :41 C)GD................ ... .............. .. ............. ..........6.... D.... ... .. ....... GD . . ...............D.5.. ........ ........................ —E 4. P) -2,4,6 PA -10,12 C82) ...... 3 8 3 8 PC -1,3,5 QQ . . . . . . . . . . ....�1 ...... . .... ..... .... .. ...................... . ... .......... PA -1,3 CD CD GD ................................ ................ ............................. .. ............ I ... ........ 5) ............... ........... ....... ...... ...... ............. .... ...... ...................... PB -19 I PC -10,12 CD GD GD GD -2 ... . PC ......................... 8 GD PB -5,7,9 PB 14 PC -4.6,8 ...... 8 RACK'C' .......... ........................ ...... ..................... ................. ............ ......................... ........ ........... ...................................... 7 T t ............................................................. ................. ....................... .......................... .............. .... ... ........... ... ......... ......... ...... ..... .. .......... .......... ......... ...... ........ j .............................................................. ............ 3 8 ....... I .... . . .......... ................ .......... PG3- 2 RACK 'A.' ..................... ...................................................... ..... ...... .......... ...................... .......... ............................. ............................ J 4 1 PC -10, PB -29,31 ......... ....... .................. .................... ............... ........ ........ I. ......... ........ .......... ...... A5 4K ........... .................................. G11-4 .................... ......................................................... - ............................ ......... ....................... ............................ - ... ......... PA -37,39,41 .......... ....................................... ....... ......................... ................ ........... .................................................................................................. 00 PA -37,, PB -22 .................................. . ......... ............ .......... ............................................................................... .............. I ...................... .............................. I. .... ................. . .. .... ............ I.::............. ........................ .,;:; .......... ... ..I......................................... ..... .. - — - — - — - — - — -- ................. .............. I ........... ................ ...... ....... .............. .................... ................. ................................................................ ......... ......... .......... ............ q CA9) . ............. I ........ .......... I ................. I .. . ....... .................. .. I .......... I .................... I ........ ......................... 0 _NEW CONDENSER V a NEW CON W.H. XA05-1 80 > >> > > 0 X TO RACK z. U) C: X ECP c= 1,47,zl I TT7_ ................ .. ". ------- - — - — - — - ------ .... .................................................... ........ ........ ....................................... ...... ............................. 3.6 TOR .................... ..................... ....... ....... PA PB PC JB SWE \T MISI:R .......... ....... ......... .... .................. ....... ...................... .......... PB -11,13 3-1 3 8 ......... EXISTING ...... ELECTRICAL ROOM .......... ......................... ....... .......... ........ .................................. .............................................................. ------ ---- - — - — - — - — - — --- . ............. ............. - .. .......... : : .. : ..... ............. ............ .. . ............................ ... ................. .. .... ............. ............ .. —03 CD— — . . ................... .......... ................................ .............................................................. ................................................................................................................................. T6 DENOTES RACK 'A' (TYPICAL) ...................... .......... .............................. ................................ ....... ...................... ...................... ...... ............................... .......... 4 as 10 ............................... .......... ................ ................... ........... .......................... ..... ..................... .............................. ....... 9 ................ RACK W .......... 9 .5 A3 -C2.)4 .. ... ............................ ............. ........ .................... ........ ....... . ...... ................ —_76- ...... ........ ....... .... - ........ ....... . ...... tp ........... .......... ....... ........ ................ ....... ........ ........... I A8 �8-14 �4 10 PA -29,31,33 .......... .... ........ 6 ...... ........ ....... . ......... . . .......... ......... -24 PC --i - - — - — - 3 8 .... ................................... .......................... .......... ..................... . ..... ...................................... .......... PB2416,18 ...... . .... .............. .... .... _4� ........... ............. .. .... .......... ...... 12 Al Al ICE!) ................ ................. ........... ...................... : ........... ........ .......... . ........... ............. ..... .......... RACK B-12,13, ...........} C12 C12 ........ ...... (2D P -13 ...... .. C PB�16,18,20 4 4 2 ...... ....... .. 7 -19,21,23 ................ PC ....... . (ED 3 8 3 8 PA -11,13,21 ............ 3 3 CD 3 -03 PC -1 PA -15,17 �77,_ - IPB- 15,17 fi :.1.1 ..... I ..... ................ ....... .......... .. ....................... ......... .................... ..... .. ........ ................ .......... ............. ....................... C1 'C RACK I CD SAG3-120 CD :Gz) GD GD I GD PA -26,28X I. A. I A F.�Z ru% AV% *V% a lom%k IL I IL a AO% IL a SCALE Ht1_h1UtKA I IVN Wit NU MAN 3/32't=:1%-0` SCALE Oft MEZZAN"INE P"LANlog 1 3/32"=1,-M I e. ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAL MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION, RESOLUTION AND DIRECTION BEFORE PROCEEDING WITH THE WORK. GENERAL NOTES: 1. ANTI- I SWEAT HEATER CIRCUITS SERVING CASES TO BE 2 WIRE, 1 HOT 1 NEUTRAL, FOR SERVING 6. (1) 4 -CONDUCTOR SHIELDED CABLE (#22 AWG OR LARGER) EACH CIRCUIT (DEDICATED NEUTRAL). MARK NEUTRAL AND PROPER PANEL LETTER AND CIRCUIT �2� CONDUCTOR �BLACK & WHITE-- FOR TEMPERATURE SENSOR, INDICATED AS: NUMBER AND RUN TO RELAY TERMINAL BOARD OF THE ASHG PANEL LOCATED WITHIN ELECTRIC 2 CONDUCTOR RED & GREEN) - FOR DEFROST TERMINATION, INDICATED AS: ROOM. THIS CABLE SHALL BE RUN IN A SEPARATE CONDUIT TO ABOVE CEILING SPACE AND RUN 2. ALL WIRE SHALL BE STRANDED FOR CONTROLS AND SOLID FOR BRANCH CIRCUITS, IN CONDUIT BACK TO RESPECTIVE REFRIGERATION RACK CONTROL CABLE JUNCTION BOX LOCATED IN MEZZANINE. 3. ALL CONDUIT FOR REFRIGERATED CASES SHALL BE 1". HOLD SALES AREA STUB -UPS TO WITHIN 7. JUNCTION BOXES MOUNTED ABOVE CEILING SHALL BE SUPPORTED BY STRUCTURE ABOVE, 1" OF DIMENSION. NOT CEILING GRID. 4. ALL CASE LIGHTING CIRCUITS WITH THE EXCEPTION OF THE DELI CASES SHALL BE CONTROLLED BY EMCC CONTACTOR #2 VIA LIGHTING RELAYS (NO FANS OR ANTI -SWEATS). 8. ALL CONDUIT DROPS TO REFRIGERATED CASES SHALL BE PAINTED TO MATCH SURROUNDINGS. COORDINATE WITH GENERAL CONTRACTOR. 5. ALL ELECTRICAL WRING, WILL BE DONE...IN . STRICT. ACCORDANCE WITH THE N.E.C. NO COLOR. CHANGES IN WIRE RUNS OR MISLABELED CIRCUITS WILL BE ACCEPTED. ALL WRING SHALL BE DONE ACCORDING TO KASH N KARRY SPECIFICATIONS. NO SLOPPY WORK WILL BE ALLOWED. jo TRUE NORTH PLAN NORTH LEGEND �- ELECTRICAL STUB -UP 03 DROP FROM CEILING r L J EVAPORATOR COIL ---- MAGNETIC SWITCH REFRIGERATION CIRCUIT NUMBER WIRE SIZE NOTE: (TYPICAL OF ALL SHEETS) WHERE WIRE SIZE IS SHOWN IN PANEL SCHEDULE OR ON FLOOR PLANS, THE SAME WIRE SIZE, AS A MINIMUM, SHALL BE CARRIED THROUGH OUT THE CIRCUIT. ---- ---- - _ CONTROL WIRING NOTES: 1, ( ------- . INDICATES FIELD WIRING BY THE ELECTRICAL CONTRACTOR. 2. KLIXONS ARE PROVIDED AND MOUNTED BY OTHERS. 3, SENSORS ARE PROVIDED BY OTHERS AND WIRED BY THE ELECTRICAL CONTRACTOR. NOTES (D NEW HOMERUN CIRCUITS TO PANELS INDICATED. REFER TO PANEL SCHEDULES FOR R WRING. COORDINATE NEW POWER AND CONTROL CONDUIT ROUTING TO RELOCATED AND/ OR NEW REFRIGERATED CASES WITH ARCHITECTURAL FURRED OUT CHASES AND .E KASH N KARRY CONSTRUCTION MANAGER, PRIOR TO ROUGH -IN. F Q ELECTRICAL CONTRACTOR SHALL REUSE EXISTING CONDUIT STUBS TO PANEL V OR 'D' FOR NEW REFRIGERATED CASE CIRCUITING. EXISTING CIRCUITS BEING MADE SPARE R BY ALTERATION WORK TO BE REUSED. UTILIZE EXISTING CIRCUIT LEFT FROM DEMOLITION PHASE TO WIRE NEW EQUIPMENT. REFER TO ELECTRICAL DEMOLITION KEY NOTE No. 6, DRAWING E -2D. G EXTEND EXISTING CONDUIT AND WIRE AS REQUIRED FOR RECIRCUITING OF REFRIGERATED CASES RESPECTIVE SYSTEM FAN, LIGHTING AND ANTISWEAT HEATER POWER AND CONTROL E CIRCUITS. COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR AND KASH N KARRY R CONSTRUCTION MANAGER. NOTE: A EXISTING CIRCUIT NUMBERS ARE SHOWN FOR REFERENCE ONLY. ELECTRICAL CONTRACTOR SHALL VERIFY THAT FAN CIRCUIT WRING IS 24HR NON -INTERRUPTED WRING, LIGHTING T CIRCUITS ARE CONTROLLED BY THE EMCC CONTACTORS PER GENERAL NOTE #4, AND ANTI -SWEAT HEATER CIRCUITS ARE CONTROLLED VIA THE APPROPRIATE ANTI -SWEAT CONTROL PANELS CONTACTOR PER GENERAL NOTE #1. 04 PROVIDE CONTROL CABLE TO REFRIGERATION RACK SHOWN. SEE GENERAL NOTE No. 6, N AND DETAIL #1 /E -2K. ON THIS SHEET. (D EXISTING COMPRESSOR RACK 'C' TO BE REFURBISHED. COORDINATE WITH REFRIGERATION CONTRACTOR AND PROVIDE ANY WRING AND EQUIPMENT P REQUIRED FOR REWIRING OF COMPRESSOR RACK. L @ UTILIZE EXISTING 120V. CIRCUIT LEFT FROM DEMOLITION TO WIRE NEW COOLER OR PREP. AREA FAN COIL UNITS SHOWN. SUPPLY AND INSTALL NEW WEATHERPROOF TOGGLE SWITCH A IF REQUIRED. N 07 U11LIZE EXISTING 208V. CIRCUIT LEFT FROM DEMOLITION, TO WIRE NEW FREEZER, COOLER OR PREP. AREA FAN COIL UNITS SHOWN. EXTEND EXISTING CONDUIT AND WIRE AS REQUIRED FOR FAN COIL, DOOR SWITCHES, DEFROST TERMINA11ONS AND SENSORS, PER RESPECTIVE DETAILS #2/E -2k OR #3/ E -2k, PROVIDE AND INSTALL NEW CONTROL CABLE AND WEATHERPROOF FAN COIL DISCONNECT SWITCHES PER GENERAL NOTE #6, IF REQUIRED. COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR AND FOODLION CONSTRUCTION MANAGER. @ REFER TO DETAIL #1/E 2k FOR RECONNECTION OF EXISTING DEFROST TERMINATION CONTROLS. PROVIDE AND INSTALL NEW CONTROL CABLE PER GENERAL NOTE #6, IF REQUIRED. COORDINATE ALL WORK WITH REFRIGERATION CONTRACTOR AND FOODLION CONSTRUCTION MANAGER. 09 ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL BLANK POWER POLE EQUAL To WIREMOLD #25DTP-412 FROM SUSPENDED CEILING DOWN TO DISPLAY CASE. 10 RUN 3/4" CONDUIT FROM CONDENSER RACK CONTAINING (1) 2 -WIRE SHIELDED CABLE (BELDEN #8760) FOR COMMUNICATION TO RESPECTIVE COMPRESSOR RACK CONTROLLER IN MEZZANINE. FIELD COORDINATE NTH REFRIGERATION CONTRACTOR. ONLY SHIELDED CABLES SHALL BE RUN IN THIS CONDUIT. 11 ELECTRICAL CONTRACTOR SHALL PROVIDE CONNECTION TO REFRIGERATION CASE PLENUM ANS AS REQUIRED, REFRIGERATION CONTROL JUNCTION BOX .... TYP. ELECTRICAL CONTRACTOR SHALL I RECONNECT' NECT ANDIOR PROVIDE NEW TEMPERATURE SENSOR CONTROL WRING FOR SENSORS NOT SHOWN, PER KASH N KARRY CONSTRUCTION MANAGER AND REFRIGERATION CONTRACTOR I I RED & GREEN -TYPICAL CASE DEFROST TERMINATOR V) WIRES 0 0 - 0 --a- (MULTIPLE CASES) 1 __j-1 ! 2 M -.- w 0 0 (2 CASES) 0 0 (1 CASE) C5 NOTES: CONNECT CLOSE ON RISE TERMINATION CONTROL BETWEEN TERMINAL BLOCKS. IF MORE THAN ONE CASE, WIRE CON- TROLS IN SERIES. 6— TYPICAL CASE CONTROL WIRING EKJFOR HOT GAS CONTROL WIRE ALL CONTROL WRING FOR CASES AND SHALL TERMINATE AT THE RESPECTIVE COMPRESSOR RACK'S REMOTE MANIFOLD: INSTALLATION OF CONTROL CABLES SHALL BE AS PER FOOD LIONS SPECIFICATIONS WITH THE CABLE SHIELD GROUNDED AT THE RACK AND TAPED OFF AT THE CASE. FAN KLIXON 208 VOLT BLUE __3MFAN COIL MOTOR (TYP) RED - ----- SINGI E -POLE DRYCONTACT-RE©----�G MAGNETIC SWITCH DEFROST TERMINATION RED TERMINAL BLOCKS GAN __1__j__DEFROST TERM" (RCJB) INATION KLIXON (AT COMP. RACK) MTD ON FAN COIL NOTE, INSTALL A RED & GREEN WIRE FOR DEFROST TERMINATION. INSTALL 2 RED WIRES TO THE MAGNETIC SWITCH. INSTALL 2 BLUE WIRES FOR POWER & FAN CONTROLS WIRE CONTROLS IN SERIES AS SHOWN (IF REQUIRED) I�NTYPICAL STORAGE FREEZER, MEAT FREEZER, �K ICE CREAM FZR & DELI FZR CONTROL WIRING FAN 208 VOLT KLIXON LLkLE_ PL(LE_-6_�i3� FAN COIL MOTOR (TYP) DEFROST TERMINATION—. DEFROST TERM - TERMINAL BLOCKS AD INATION KLIXON MTD ON FAN COIL REFRIGERATION CONTROLLED JUNCTION BOY AT COMP. RACK INSTALL A RED & GREEN WIRE FOR DEFROST TERMINATION. INSTALL 2 BLUE WIRES FOR POWER & FAN CONTROLS * WIRE CONTROLS IN SERIES AS SHOWN (IF REQUIRED) TYPICAL MEAT COOLER CONTROL WIRING I N T E R N A TI 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281-9299 Fax 8132811.922% E—Mail.pi@architectureplus.com License #AAC001935 CHEHAYEB & ASSOCIATES, INC. CONSULTING ENGINEERS 3702 AZEELE St (813) 876-1 3 TAMPA, FL 33609 9977 (Jhx) 876 -(Li moniffilow JIM ..AV k h a ti I Kaiy I WUE DATE ®l ISSILE FOR PERMT *AS DATED ARC',HITECTUREIPLUS INTEWATK)NAL, INC. A ..................................................... A ..................................................... A ..................................................... A ..................................................... REVISION LOG I ......................... ... ................... TO Dr- BMT CV _R -E ""AWCE CF RE 9l-1 ffB= Iq_0 0"Em, = R.Aw� AID sf�TM CMFLY YMN 1 FE AFF"RE WMN UDM 0-M AAD TE Affl"SX- W" HE WW STAVAFW AS CBEEY.� N PCOaqWU MM CWPM--S 6M " = CF 1W %7 UfFUHM TO 1-E R -%M STATUTE KASH N' KARRY NO. 1?8`90 ......... I ... ................... I .................. .SANF,OR.D,.. fL. ........... MOJUCT WJV1E REFRIGERATION -WIRING ... PLAN... I ...................................... SHEET NAME PRCQJECT NUKELER 909409.01 ... I ..... I ................................. I ......... DRAWN BY. SKC/BA (>EG1(ED BY: SC ............................... SCALE. AS NOTED ... ............. I ......................... PLOT DATE- 9/6/01 .................. I ...... ISSUE FOR .......... 11 RAT lam ..................... .......... SHEET NUMBER 0 0 1 30 1 �1 0 0 + DENOTES ADDITIONAL LOAD TO PANEL (CUTLER—HAMME NUFACTURER CHALLENGER MATY PANEL PE PRL 1 IH2 EX AMPERE INTERRUPTING C, No.1 KVA CONT. WARE OND I COND 1 — — EX EX EX 3 = — EX EX EX 5 — — EX EX EX 7 — — EX EX EX T 9 — — EX EX EX 11 0.1 C2 3#10 1#10 3/4" 13 0.1 — 15 — — EX EX EX 17 — — E:X EX EX 19 21 — 0.1 A — EX 2#10 EX 1 #10 1 EX 3/4" 23 — — EX EX I EX 25 — — EX EX EX 27 - - EX EX EX 29 — — EX EX EX 31 — _ EX EX EX 33 — — EX EX EX 35 - _ EX EX EX 37 0.1 — 2#10 1#10 3/4" 39 0.1 — 3#10 41 0.1 C2 CONNECTED LOAD KVA +4.1 (VOTE: ALL BREAKERS 20A, UNLE 0 0 G `4 + DENOTES ADDITIONAL LOAD TO PANEL 0 02- 02 2 + DENOTES ADDITIONAL LOAD TO PANEL WIRE SIZE NOTE: (TYPICAL OF ALL SHEETS) WHERE WIRE SIZE IS SHOWN IN PANEL SCHEDULE OR ON FLOOR PLANS, THE SAME WIRE SIZE, AS A MINIMUM, SHALL BE CARRIED THROUGH OUT THE CIRCUIT. PANEL SCHEDULE LEGEND: �1 DISCONNECT AND REMOVE EXISTING SPARE CIRCUIT BREAKER. PROVIDE AND INSTALL NEW MATCHING CIRCUIT BREAKERS SHOWN AND CONNECT TO NEW CIRCUITS. O PROVIDE AND INSTALL NEW MATCHING CIRCUIT BREAKER SHOWN IN EXISTING SPACE. VERIFY EQUIPMENT REQUIREMENTS WITH KASH N KARRY CONSTRUCTION MANAGER PRIOR TO ORDERING CIRCUIT BREAKERS. NEW LIGHTING CIRCUITS SHALL BE RUN THROUGH LIGHTING CONTACTORS FOR ENERGY MANAGEMENT SYSTEM CONTROL. I FGFNn EXISTING TO REMAIN NEW 10 10 I� ARCHIT[CTURV [us I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33007 Tel 813281.9299 Fax 813281092' E—Mail apiC%rchitectureplus.com License #AAC001935 CHEHAYEB & AS'S'OCIATES, INC. CONSULTING ENGINEERS 3702 AZEELE ST, f CTS (813) 876-14115 TAMPA, FL 336nQ 9977 (fax) 876-0913 *,F firma If my Aw „f ISSUE DATE . 09/10611011 ISSUE FOR PERMIT CCAS DATED ARC!-IITECTUFEPLUS INTEF NATONAIL, INC_,_ D ..................................................... D .................................................... O ................................................... D ..................................................... REVISION LOG ................. .............. I ............... TO TF[ W;;T C: DE 1Qn4W . 3 OF R5 A9,kftE= ND Fh"fg"' = nRjS:,gV UirMA ,r9 MWLY L`^` -t THE MICA'1.E MAM MUM CCDES AND Ti E PfFtY-ABLE N"" FR : UY STPhffM AS CETEiMED f4 ACCCFUAME VM CKW FRB p3 AM 633 CF- T}E 1987 UfFLEh'EM TO TW R -CFM 5TATM SH ' ARRY N.0.'.1890 .SANF............... . FLS........................ PPUECT NAME TIL SHEET NAME CT.R 9949.01 ...................... I ................. I............ j DRAWN BY: SKC/BA BY: SC ....... .... ........................ I................. SCALE: NO SCALE PLOT DATE: 9/6/01 MSW Ems' ................................... I ......... ....... SHEET NUMBER (CUTLER. -HAMMER) EXISTING MANUFACTURER CHALLENGER PANEL TYPE LOAD CENTER 120 VOLTS j EX AMPERE INTERRUPTING CAPACITY PANEL UPS SPECIAL — PH. 3 WIRE/SOLID NEUTRAL 100 AMPERE BUS 100 AMPERE MAIN LUGS MOUNTING: FLUSH X SURFACE LOCATION OFFICE No. KVA CONT. `dBRE GND. COND. DESCRIPTION 40A A — — — 2.2 , B 50A 2.2 1.2 '�� DESCRIPTION WIRE GND. GOND. CONT. KVA No. 1 3.0 — EX EX EX BY—PASS TO UPS UPS IN',PUT EX EX EX — 3.0 2 3 1.2 — 2#10 1#10 3/4" DIRTY POWER REG. #5, #6 REGISTER COOLER 2#12 1#12 3/4 — 1.0 4 5 1.2 — 2#10 1#10 3/4" DIRTY POWER REG. #3, #4 REGISTER COOLER 2#12 1#12 3/4" — 1.0 6 1#10 3/4" DIRTY POWER REG. #1, #2 SPACE ONLY — — — — 8 CONNECTED LOAD KVA 5.6 KVA SUB TOTALS 2.2 3.4 DEMAND FACTOR 1.0 DEMAND LOAD KVA 5.6 NOTE ALL BREAKERS 20A, UNLESS OTIiERWiSE NOTED. DEMAND AMPERES 15.6 WIRE SIZE NOTE: (TYPICAL OF ALL SHEETS) WHERE WIRE SIZE IS SHOWN IN PANEL SCHEDULE OR ON FLOOR PLANS, THE SAME WIRE SIZE, AS A MINIMUM, SHALL BE CARRIED THROUGH OUT THE CIRCUIT. PANEL SCHEDULE LEGEND: �1 DISCONNECT AND REMOVE EXISTING SPARE CIRCUIT BREAKER. PROVIDE AND INSTALL NEW MATCHING CIRCUIT BREAKERS SHOWN AND CONNECT TO NEW CIRCUITS. O PROVIDE AND INSTALL NEW MATCHING CIRCUIT BREAKER SHOWN IN EXISTING SPACE. VERIFY EQUIPMENT REQUIREMENTS WITH KASH N KARRY CONSTRUCTION MANAGER PRIOR TO ORDERING CIRCUIT BREAKERS. NEW LIGHTING CIRCUITS SHALL BE RUN THROUGH LIGHTING CONTACTORS FOR ENERGY MANAGEMENT SYSTEM CONTROL. I FGFNn EXISTING TO REMAIN NEW 10 10 I� ARCHIT[CTURV [us I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33007 Tel 813281.9299 Fax 813281092' E—Mail apiC%rchitectureplus.com License #AAC001935 CHEHAYEB & AS'S'OCIATES, INC. CONSULTING ENGINEERS 3702 AZEELE ST, f CTS (813) 876-14115 TAMPA, FL 336nQ 9977 (fax) 876-0913 *,F firma If my Aw „f ISSUE DATE . 09/10611011 ISSUE FOR PERMIT CCAS DATED ARC!-IITECTUFEPLUS INTEF NATONAIL, INC_,_ D ..................................................... D .................................................... O ................................................... D ..................................................... REVISION LOG ................. .............. I ............... TO TF[ W;;T C: DE 1Qn4W . 3 OF R5 A9,kftE= ND Fh"fg"' = nRjS:,gV UirMA ,r9 MWLY L`^` -t THE MICA'1.E MAM MUM CCDES AND Ti E PfFtY-ABLE N"" FR : UY STPhffM AS CETEiMED f4 ACCCFUAME VM CKW FRB p3 AM 633 CF- T}E 1987 UfFLEh'EM TO TW R -CFM 5TATM SH ' ARRY N.0.'.1890 .SANF............... . FLS........................ PPUECT NAME TIL SHEET NAME CT.R 9949.01 ...................... I ................. I............ j DRAWN BY: SKC/BA BY: SC ....... .... ........................ I................. SCALE: NO SCALE PLOT DATE: 9/6/01 MSW Ems' ................................... I ......... ....... SHEET NUMBER KV'A LIGHTING (ADD). . . . . . . . . . 9..0 REFRIGERATION (ADD) . . 9.4 DELI/ BAKERY (ADD) 5.4 KVA @ 70% . . . . . . . 3.4 (PER NEC 220.20) EXISTING BUILDING LOAD (PER N.E.C. 220-35). . . . . . 543.8 TOTAL. . . . . . .565.6 KVA 565.6 KVA 120/208V, 3ph, 4VN = 565,600- 2087\5 = 1571 AMPS EXISTING SERVICE IS 2000 AMPS 120/ 208V. 3PH, 4W PEAK DEMAND PREVIOUS 12 MONTHS (PER F.P.& L.) = 348 KW * 348 KW ® .8pf = 435 KVA x 1.25 = 543.8 KVA LIGHT FIXTURE SCHEDULE VOLTS 208 120 120 208 120 120 120 120 120 120 120 120 120 120 120 120 120 120 LOCATION/MTG. CEILING/RECESSED PENDANT CEILING/RECESSED WALL/SURFACE CEILING/RECESSED CEILING/RECESSED CEILING/RECESSED CEILING/RECESSED SUSPENDED TRACK WALL/SURFACE CEILING/RECESSED CEILING/RECESSED SUSPENDED TRACK CEILING/LAY-1N UNIVERSAL UNIVERSAL CEILING/RECESSED CEILING/LAY—IN REMARKS NOTES 1 & 2 NOTE 9 NOTE 10 NOTE 3 NOTE 3 - - NOTES 4, 5, & 8 NOTES 1 & 6 - NOTE 1 NOTES 7 & 8 — NOTES 1 & 6 NOTES 1 & 6 NOTE 11 — NOTES: 1- PROVIDE FIXTURE WITH BATTERY BACKUP, WIRE BATTERY AHEAD OF ALL SWITCHING. WHERE THE BATTERY IS A PART OF THE FLUORESCENT FIXTURE. BATTERY BALLAST SHALL PRODUCE 1300 LUMENS MINIMUM. 2. SUSPEND FIXTURE WITH AIRCRAFT CABLES TO 9'-0" A.F.F. °f0 BOTTOM OF FIXTURE. COORDINATE MOUNTING OF DECORATIVE MOLDING WITH GENERAL CONTRACTOR, 3. MOUNT FIXTURE ABOVE INDICATED CASES. AIM FIXTURE UPWARD WITH REFLECTORS ORIENTATED TO WALL WASH.. REFLECTOR COLOR SHALL MATCH EXISTING. 4. REFER TO LIGHTING PLAN FOR NUMBER OF HEADS AND TRACK LIGHT LENGTH. TRACKS SHAH BE NOKIA #XTSA-AR2-5 SUSPENDED WITH AIRCRAFT CABLES TO 9'-0" A.F.F. TO BOTTOM OF FIXTURE, EXCEPT IN BAKERY, DELI AND SEAFOOD AREAS TO BE MOUNTED ON CEILING. 5. OWNER PROVIDED FIXTURE. ELECTRICAL CONTRACTOR TO INSTALL AND WIRE. 6. FIXTURE COLOR TO MATCH EXISTING, FIELD VERIFY. 7. REFER TO LIGHTING PLAN FOR NUMBER OF HEADS AND TRACK LIGHT LENGTH. TRACKS SHALL BE (2) CIRCUIT TRACK. SUSPEND WITH PENDANTS TO 9'-0" A.F.F. TO BOTTOM OF FIXTURE. PROVIDE ALL MOUNTING AND POWER FEED ACCESSORIES AS REQUIRED. 8. CIRCUITING OF TRACK HEADS SHALL BE DISTRIBUTED EVENLY AMONG CIRCUITS. 9, TRIM COLOR TO BE SELECTED BY ARCHITECT, COORDINATE WITH CEILING TYPE. 10. REFER TO ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT AND EXACT LOCATION. 11. ELECTRICAL CONTRACTOR SHALT- PROVIDE GE LAMPS (NO SUBSTITUTIONS) WITH TUBE SHIELDS �PE�tAL NOTE:.. LIGHT FIXTURES SHALL BE MANUFACTURED BY LITHONIA (U.O.N.). THESE ITEMS SHALL BE PURCHASED FROM GENERAL ELECTRIC SUPPLY COMPANY AT THE NATIONAL CONTRACT PRICE. CONTACT DEBBIE CALDWELL AT (704) 597-6760. FSYM. MANUFACTURER LITHONIA CATALOG NO. GS-250MH LAMPS (1) 250W., M.H. A PM3X-232-8LD—EL—GE8 (2) FLT8 32W/SP-35 B LITHONIA AH-175M-9AR120 (1) 175W., M.H. COATED LAMP C LITHONIA DALTOR HWR-818—IR-70MH—CLMB —LT—WHT-120 CASR-96—WH—GEB CASR-48-WH-GEB (1) 70W., M.H. D (1) FLT8 59W/SP-35 E LITHONIA (1) FLT8 32W/SP-35 E1 LITHONIA LITHONIA C-248-120-GEB (2) FLT8 32W/SP-35 E2 AF-1/26DTT-6AR-LS (OWNER PROVIDED) 6ELM2 (1) 26W.DTT F LITHONIA (1) 70W, M.H. G AMERLUX PROVIDE W/UNIT H LITHONIA L LITHONIA (3) FLT8 2SPF-332—GEB 32W/SP-35 2SPF-332—GEB—EL (3) FLT8 32W/SP-35 TGR30—WH—T4 PAR30 75W (3) FLT8 2SPG-332—GEB 32W/SP-35 LOM -SW -1R -EL LED LQM—SW-2R—EL LED PM3—G13332- 81-D-1 20-1/3GEB (3) FLT8 WITH TUBE SHIELDS 32W/SPX-35 Li LITIiONIA M LITHONIA N LITHONIA P LITHONIA P1 LITHONIA MACHINE ROOM MEZZANINE Q LITHONIA R LITHONIA 2SPG-432—GEB (4) FLT8 32W/SP-35 POWER RISER KEY NOTES: (1 PROVIDE AND INSTALL NEW MATCHING CUTLER HAMMER 3P -300A CIRCUIT BREAKER TRIP MODULE IN EXISTING FRAME UNIT SERVING REFRIGERATION RACK 'C' BEING REFURBISHED, DISCONNECT AND REMOVE EXISTING FEEDER FOR REFRIGERATION RACK 'C' AND RUN NEW FEEDER SHOWN AND CONNECT TO NEW REFRIGERATION RACK 'C'. SEE SWBD. NOTES BELOW. QDISCONNECT AND REMOVE EXISTING 3P -40A C/B SERVING ROOF TOP CONDENSING UNIT 'C' BEING REPLACED, FURNISH AND INSTALL MATCHING 3P -30A CIRCUIT BREAKER AND RECONNECT TO EXISTING FEEDER. SEE SWBD. NOTES BELOW. SWITCHGEAR NOTES: ELECTRICAL CONTRACTOR SHALL EXAMINE SWITCHGEAR PRIOR TO BID AND VERIFY THAT EXISTING CIRCUIT BREAKERS ARE CAPABLE OF BEING REFURBISHED AND PROVIDE NEW CIRCUIT BREAKER FRAMES, MOUNTING HARDWARE AND FILLER PLATES IF REQUIRED. CIRCUIT BREAKER SHALL MATCH EXISTING A.I.C. RATING VERIFY PRIOR TO ORDERING. NEW 3#350 MCM CU. & 1#4 E.G. IN 3"C, ARCHITECTUREPLUS I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 i el 813281.9299 Fax 813281.9292 E—mail apCarchitectureplus.com License #AAC001935 CIIEIIAYEB do ASSOCIATES, INC. CONSULTING ENGINEERS 3702 AZEELE S1'. (813) 875-1415 TAMPA, FL 33609 9977 (fax) 876-0913 ISSUE DATE o 09/06/01 ISSUE FOR PERMIT CAS DATED ARCHITECTUiCPLUS INTERNATIONAL; INC: A. .................. 11 .......... L............ ................................... A., ............. I ................. I ....... ........D .......... I .............................. REVISION LOG J ....................................... zo 1F� car x r� ta�rartt� � n+� arsa�:> Fra eass� �a starve ua ktlCt�t'i CC�Y Hil}I TFE AFH.IC?,�E }R�8JA16A F3�.LW3 CCCE� tv�D 1}+E cssst aceto as � � � � Toga sr� vnrr+ PPQECT NAME � PPO,ECT R 9949,91 ..................................................... DRAWN BY: SKC/BA CES EY: SC .....................................I............... SCALE: NO SCALA ..... ................................................. PLOT DATE: 9/6/01 IS&K FOR ...................................................... ..................................................... q ",ET NUMBER r----------------------------, 1 I __---- J I ------ I 1 I I I I I 1 I I I I I I PANEL i PANEL i i PANEL I LA 1 1 LB I I LC 1 l !! 1 1 I I I I I I I I I i t 1 I L ------J 1----�---J 1----�---J I i I I REFURBISHED I I 1 REFRIGERATION COMP. RACK 'C' r-----L--------'----------'-- MACHINE ROOM MEZZANINE L------ --------------------------- I —DELI /BAKERY -- FRONT OFFICE ELECTRIC ROOM 1 --- --- ----- --------------� l E 11�--L----� r--------------- , i----------------- I I I 1 I 2000A – – – – – 3P -100A I I ! ° 11P-50Ar PANEL EM PANEL UPS 1 I I I 1 I I 1 i MAIN BOLTED -------I-------4 1 1 I I I 1 t PRESSURE I 3P -150A I SPACE 1 1 I I I_ AHI �____-- { I I I ---- I I I I I t I I. 1 L__ I 1 SWITCH WITH I SHUNT TRIP �- 1 ®�► I -- i 1--- !- --- –I 1 3P -225A 113P -30A ! I J--- _ I–=– 1–_ _... . .- C– _ .... r __–---E (_-1-- – 1 t ----i – i ------ j k �PANEL_fJa' BOND. C �-4 I 11 I I I I I j I I I I 11 1 I t i I 120 208V i / I PANEL 18' i a�r;� ®` i 1 i t PANEL 1 1 PANEL I I PANEL 1 11 ► 1 PANEL 1 1 PANEL 1 1 PANEL 1 1 PANEL t 1 1 1 I I1 'UPS' 1 PANEL 1 1 , CR 1 SHUNT TRIP j I 3—PHASE I I------- t -------I 1, , ' I 3P -225A 1 3P -225A I I PA I I PB I I PC 1 'LC' PANEL PC' I I I I 1 EM l i D i B i i I 4-ti"DIRE I PANEL I I I I j PUSH BUTTON I 1 r 3P -225A I 3P -225A i I i I I I I I I I 1 I I I I rel l`J I 1 PANEL 'PA' 1 PANEL 'B L------4-- o—J L L---r--J L ---,---J L ------J I L ------J L ------J L–� ----J L--- i---1 ------J 1 3P -300A F3–P=30 0A LACK 'A' 1 I i LRACK r --------i- j I 3P -250A I 3P -250A I I RACE: °B° I 'DUCT HTP.' t I L-------t-------I I 3P -400A 13P -250A F PANEL °D' I AC COND.LIGHTNING ARRESTOR L I--------------� --r-- -------------- ------------------------ -----------------------^--------------_J—TO ------------- -J— ; � EXISTING PaWER RISER TO,FLORIDA POWER &LIGHT N.T.S. TRANSFORMER_4 ARCHITECTUREPLUS I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 i el 813281.9299 Fax 813281.9292 E—mail apCarchitectureplus.com License #AAC001935 CIIEIIAYEB do ASSOCIATES, INC. CONSULTING ENGINEERS 3702 AZEELE S1'. (813) 875-1415 TAMPA, FL 33609 9977 (fax) 876-0913 ISSUE DATE o 09/06/01 ISSUE FOR PERMIT CAS DATED ARCHITECTUiCPLUS INTERNATIONAL; INC: A. .................. 11 .......... L............ ................................... A., ............. I ................. I ....... ........D .......... I .............................. REVISION LOG J ....................................... zo 1F� car x r� ta�rartt� � n+� arsa�:> Fra eass� �a starve ua ktlCt�t'i CC�Y Hil}I TFE AFH.IC?,�E }R�8JA16A F3�.LW3 CCCE� tv�D 1}+E cssst aceto as � � � � Toga sr� vnrr+ PPQECT NAME � PPO,ECT R 9949,91 ..................................................... DRAWN BY: SKC/BA CES EY: SC .....................................I............... SCALE: NO SCALA ..... ................................................. PLOT DATE: 9/6/01 IS&K FOR ...................................................... ..................................................... q ",ET NUMBER EF- 4 �-- TIE TO AN EXISTING UNSWITCHED NON CR PANEL CIRCUIT NEW TELEPOWER POLE SEE TELEPOLE INSTALLATION NOTES ON SHEET E5.1 CASHREGISTER (TYP. FOR EACH REGISTER) LOCATION (TYPICAL) VISA COOLERS (TYPICAL OF 2) ....... SEE REGISTER INSTALLATION NOTE #2 ....... ON SHEET E5.1. i 1O (TYPICAL) 46 :• f COORDINATE RECEPTACLE MOUNTING AND CONDUIT CR t CR -3 CR -5 ROUTING WITH MILLWORK CR- 2CR-6 CR -4 (TYPICAL) /,\03 --------------------------- ------------------- x 7. ----------- -:COMMUNICATIONS ........Ic 'JUNCTION BOX +S-0" EX:: ...... NEW SENSORMATIC CONTROLLER MOUNTED ABOVE HUNG CEILING VERIFY LOCATION WITH KASH N. KARRY CONSTRUCTION MANAGER. EXTEND 3" CONDUIT TO CONTROLLER UPS -5,6 UPS -4,7 UPS -3 B-18 B-17 INX r2 -5, . 6 E5.1 E5.1 HUBBELL MG -5262 RECEPTACLE TYPICAL FOR 'CR.' RECEPTACLES --------------------------- -------- C ------------------ - --------------------------------------- ) CR -9 RELOCATED SENSORMATIC TIE TO EXISTING 'CR' TIMECLOCK CIRCUIT CONTROLLER, MOUNTED AT BASE OF WALL WITH 2,912, 1112 I.G. & 1 #12 E.G. IN 1/2C, NEW 3" PVC CONDUIT IN SLAB ......... .... PEDESTAL J: ip-on (TYP. of 5) ............... ' 4 F T L "N IT SCALE OFFICE &HEGASTER ELECTRICAL AL LAAYUU ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAL MUST BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION, RESOLUTION AND DIRECTION BEFORE PROCEEDING WITH THE WORK. ANTI -THEFT SYSTEM -INSTALLATION NOTES 1. THE 24" x 24* CONTROLLER IS SUPPLIED BY OTHERS. IT REQUIRES I POWER SOURCE RATED AT 120 VAC, 4.5A. 540VA. IT MUST BE ON A DEDICATED CIRCUIT AND ON THE SAME PHASE AS THE SENSORMATIC POWER UNDER THE REGISTERS. 2. USE THIS RECEPTACLE FOR FAN TRANSFORMER. TRANSFORMER PROVIDED BY OTHERS. LEAVE THE BOTTOM OUTLET OPEN SO TRANSFORMER WILL FIT. THE TRANSFORMER Is RATED AT 120 VAC, .125A, 15VA. 3. PROVIDE A 3- PVC, CAPPED AT BOTH ENDS AND RUN AT THE BASE OF THE CONCRETE SLAB. CENTER OF CONDUIT TO BE 4" OFF FINISHED WALL CONDUIT TO BE STUBBED UP UNDER THE 2X4 BOX FOR THE SECURITY CONDUIT. 4. THIS BOX FOR INSTALLATION OF SPEAKER PROVIDED BY OTHERS. PROVIDE 1/2" CONDUIT FROM TOP OF BOX TO 12* ABOVE FINISHED CEILING. RUN CONDUIT IN WALL WHERE POSSIBLE. 5. USE THIS UTILITY BOX FOR THE SECURITY DRY CONTACT WIRE THAT GOES TO THE OFFICE STORAGE. ELECTRICAL CONTRACTOR TO PROVIDE A PULL STRING FOR WORK TO BE DONE BY OTHERS. 6. THE ELECTRONICS ENCLOSURE IS PROVIDED BY OTHERS, IT WILL BE MOUNTED FLUSH WITH FINISHED FLOOR, U.O.N. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL UTILITY & JUNCTION BOXES AS SHOWN. THE BOXES ARE TO BE RECESSED FLUSH WITH FACE OF FINISHED WALL REGISTER WIRING LEGEND DIRTY CIRCUIT No, 1(BELT MOTOR, STAND LIGHT, GEN. RECEPS.) DIRTY CIRCUIT No. 2 (SENSORMATIC DEACTIVATION PAD) CLEAN CIRCUIT No. I (REGISTER, CATALINA, DEBIT CARD, SCANNER & SCALE, SPARE RECEP.) 1/2-0 CONDUIT ABOVE CEILING. 2x4 BOX FOR REMOTE— ALARM (BY OTHERS) SEE ANTI -THEFT NOTE #4. 10" 2X4 UTILITY BOX, SEE ANTI -THEFT NOTE #5 2X4 UTILITY BOX. SEE ANTI -THEFT NOTE #2 24" x 24" CONTROLLER SEE ANTI -THEFT NOTE #1 r------- -- ------ F. T F. 4" CONCRETE SLAB 4' CRUSH STONE BASE COMPACTED EARTH -1/2"0 CONDUIT ABOVE CEILING TO ADJACENT CONTROLLER OR OFFICE. 1/2- CONDUIT (BY ELECTRICAL CONTRACTOR) THIS CONDUIT TO BE PAINTED TO MATCH WALL AS NEEDED. EDGE OF WALL AT VESTIBULE OPENING SECURITY CONDUIT TO OFFICE STORAGE AREA (1/2" CONDUIT) 1/2"0 CONDUIT INPUT POWER FROM DELI PANEL PANEL"B" STUB UP 6" A.F.F. -4 4 :4 -44 3" PVC, CAPPED AT BOTH ENDS. RUN AT BASE OF SLAB, 4" OFF FINISHED WALL TO CENTER. SEE ANTI -THEFT NOTE No. 3. — ANTI -TI -EFT SYSTEM R00"'UGO""H-IN ELEVATION I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 8132810 9 Fax 813281.9292 E -Mail api@architectureplus.com License #AAC001935 CHEHAYEB & ASSOCIA-TES, INC. CONSULTING! ENGINEERS 3702 AZEELE ST. (813) 876-105 TAMPA, FL 33609 9977 (fax) 876-0913 ME AV aph if iL ff 1c.,arry ISSUE DATE : 09/06101 ISSUE FOR PERNT MRFPI.LJ,_9 IUTF_=jkT*N4.,L IIJG A .................................................... A .......... ............... ... ........................... A .................................................... REVISION LOG ....................... ................ T071F WST CF TPC or TWE Alafrmr. AID &14rclm %' D RLNS AID F,F££fflCAWCS CCMILY WITH TW APKCASIE hff" RXDW CCCES AW TIE AFREAM W*" WE SAFM ST40AMS AS CUtq ACOC"J," MM CWffF,S 533 AW 6W CF THE T" SI TU3,UM TO 7W R-ORCA STAWM 0. ­ 1 * 890 SANIF.01R.13, ... FL., ....... I ............... PPQECT NAME .ELIECTRIC.A.L..L.A.Y.OUT FOR OFFICE & REGISTP.-RS ............. I ............................... SHEET NAME ROJECT MMILER 9949.01 .................................... I ................ DRAWN BY. SKC/BA CHECKED BY: SC ............... I ..... I ........ ...................... SCALE. AS NOTED ............... I I ............ ....................... PLOT DATE: 9/6/01 L98M FOR 000M mom Emw b ............................ S. r__ET NUMBER NOTES P EXISTING EQUIPMENT AND CIRCUITING IN THIS AREA TO REMAIN, (U.O.N.). 10 PROVIDE BELDEN CABLE #9829 LOOP BETWEEN REGISTER CPU AND EACH REGISTER LEAVING A 6 FOOT LOOP OF CABLE AT EACH REGISTER WITH 0 COORDINATE INSTALLATION OF ALL RECEPTACLES IN COUNTER MILLWORK WITH SUPPLIER/ A HOME RUN BACK TO THE REGISTER CPU FROM THE LAST REGISTER. INSTALLER. FR. PROVIDE EMPTY CONDUITS FROM LOW WALLS AND COUNTERS FOR POWER, COORDINATE WITH KASH N KARRY CONSTRUCTION MANAGER. W TELEPHONE, INTERCOM AND COMMUNICATIONS WRING TO FULL HEIGHT WALL FOR ACCESS UP TO HUNG CEILING JUNCTION BOX. ALL WRING CONCEALED IN CEILING SHALL BE IN 11 SUPPLY AND INSTALL NEW WIREMOLD G-3000 RACEWAY (WITH BASE AND E CONDUIT. COVER) VERTICALLY FROM HUNG CEILING ALONG WALL TO 1*�-0* A.F.F. FOR REGISTER COMMUNICATIONS CABLES. VERIFY EXACT LOCATION WITH R ELECTRICAL CONTRACTOR SHALL VERIFY ALL RECEPTACLE AND CONDUIT STUB UP KASH N KARRY CONSTRUCTION MANAGER. PROVIDE ALL MOUNTING LOCATIONS FOR FRONT OFFICE LAYOUT WITH KASH N KARRY PROJECT REPRESENTATIVE HARDWARE REQUIRED. PRIOR TO ROUGH -IN. PROVIDE CIRCUITING TO EXHAUST FAN FACTORY INSTALLED DISCONNECT SWITCH L AND INTERLOCK WITH 120V. ROOM THERMOSTAT. A CASH REGISTER LOCATION. PROVIDE (2) PULL STRINGS PER REGISTER LOCATION BACK TO REGISTER CPU VIA NEW TELEPOWER POLES AND PROMDE (2) ADDITIONAL PULL STRINGS N FROM EACH REGISTER BACK TO OFFICE VIA NEW TELEPOWER POLES FOR INTERCOM SYSTEM COORDINATE ALL CABLING WITH KASH N KARRY CONSTRUCTION MANAGER, PROVIDE 2#10, 1#10 E.G. & 1#10 I.G. IN 3/eC, TO PANEL 'CR' AND CONNECT TO IP -20A CIRCUIT BREAKER BEING MADE SPARE BY REWORKING OF CASH REGISTERS. TELEPHONE OUTLET FOR LOTTO MACHINE & MONEY ORDER. ROUTE 3/4-C. CONDUIT STUB -UP TO BAR JOISTS. RUN (2) 4 PAIR (TWISTED), 24 AWG DATA CABLE TYPE 5 OR EQUIVALENT TO TELEPHONE BOARD LOCATED IN ELECTRIC RM. PROVIIDE 6'-0" OF SLACK FOR ALL CABLE ENDS. ROUTE CONDUIT STUBS FOR TELEPHONE & INTERCOM UP TO BARJOIST. RUN PULLWIRE FOR INTERCOM. RUN 4 PAIR (TWISTED), 24 AWG PHONE 'CABLE TYPE 5 OR EQUIVALENT TO TELEPHONE BOARD LOCATED IN ELECTRIC R.M, PROVIVE 6'-0" OF SLACK FOR ALL CABLE ENDS. CONTRACTOR SHALL COORDINATE SLAB WORK WITH G.C. FOR INSTALLATION OF NEW WALKERDUCT FOR SENSORMATIC PEDESTALS. REFER TO DETAIL #1 ON THIS SHEET COORDINATE ALL WORK WITH KASH N KARRY SENSORMATIC INSTALLER FR AND PROVIDE ALL WRING AND EQUIPMENT AS REQUIRED, CONNECT BOTH CONTROLLER RECEPTACLES TO SAME SENSORMA11C CONTROLLER CIRCUIT (B-41). COORDINATE CONDUIT ROUTING FROM UNDERSLAB CONDUIT UP TO SENSORMATIC CONTRO11 I FR WITH GENERAL CONTRACTOR AND KASH N KARRY CONSTRUCTION MANAGER. ROUTING OF EXPOSED CONDUITS OR RACEWAYS SHALL BE KEPT TO A MINIMUM. ANTI -THEFT SYSTEM -INSTALLATION NOTES 1. THE 24" x 24* CONTROLLER IS SUPPLIED BY OTHERS. IT REQUIRES I POWER SOURCE RATED AT 120 VAC, 4.5A. 540VA. IT MUST BE ON A DEDICATED CIRCUIT AND ON THE SAME PHASE AS THE SENSORMATIC POWER UNDER THE REGISTERS. 2. USE THIS RECEPTACLE FOR FAN TRANSFORMER. TRANSFORMER PROVIDED BY OTHERS. LEAVE THE BOTTOM OUTLET OPEN SO TRANSFORMER WILL FIT. THE TRANSFORMER Is RATED AT 120 VAC, .125A, 15VA. 3. PROVIDE A 3- PVC, CAPPED AT BOTH ENDS AND RUN AT THE BASE OF THE CONCRETE SLAB. CENTER OF CONDUIT TO BE 4" OFF FINISHED WALL CONDUIT TO BE STUBBED UP UNDER THE 2X4 BOX FOR THE SECURITY CONDUIT. 4. THIS BOX FOR INSTALLATION OF SPEAKER PROVIDED BY OTHERS. PROVIDE 1/2" CONDUIT FROM TOP OF BOX TO 12* ABOVE FINISHED CEILING. RUN CONDUIT IN WALL WHERE POSSIBLE. 5. USE THIS UTILITY BOX FOR THE SECURITY DRY CONTACT WIRE THAT GOES TO THE OFFICE STORAGE. ELECTRICAL CONTRACTOR TO PROVIDE A PULL STRING FOR WORK TO BE DONE BY OTHERS. 6. THE ELECTRONICS ENCLOSURE IS PROVIDED BY OTHERS, IT WILL BE MOUNTED FLUSH WITH FINISHED FLOOR, U.O.N. 7. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL ALL UTILITY & JUNCTION BOXES AS SHOWN. THE BOXES ARE TO BE RECESSED FLUSH WITH FACE OF FINISHED WALL REGISTER WIRING LEGEND DIRTY CIRCUIT No, 1(BELT MOTOR, STAND LIGHT, GEN. RECEPS.) DIRTY CIRCUIT No. 2 (SENSORMATIC DEACTIVATION PAD) CLEAN CIRCUIT No. I (REGISTER, CATALINA, DEBIT CARD, SCANNER & SCALE, SPARE RECEP.) 1/2-0 CONDUIT ABOVE CEILING. 2x4 BOX FOR REMOTE— ALARM (BY OTHERS) SEE ANTI -THEFT NOTE #4. 10" 2X4 UTILITY BOX, SEE ANTI -THEFT NOTE #5 2X4 UTILITY BOX. SEE ANTI -THEFT NOTE #2 24" x 24" CONTROLLER SEE ANTI -THEFT NOTE #1 r------- -- ------ F. T F. 4" CONCRETE SLAB 4' CRUSH STONE BASE COMPACTED EARTH -1/2"0 CONDUIT ABOVE CEILING TO ADJACENT CONTROLLER OR OFFICE. 1/2- CONDUIT (BY ELECTRICAL CONTRACTOR) THIS CONDUIT TO BE PAINTED TO MATCH WALL AS NEEDED. EDGE OF WALL AT VESTIBULE OPENING SECURITY CONDUIT TO OFFICE STORAGE AREA (1/2" CONDUIT) 1/2"0 CONDUIT INPUT POWER FROM DELI PANEL PANEL"B" STUB UP 6" A.F.F. -4 4 :4 -44 3" PVC, CAPPED AT BOTH ENDS. RUN AT BASE OF SLAB, 4" OFF FINISHED WALL TO CENTER. SEE ANTI -THEFT NOTE No. 3. — ANTI -TI -EFT SYSTEM R00"'UGO""H-IN ELEVATION I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 8132810 9 Fax 813281.9292 E -Mail api@architectureplus.com License #AAC001935 CHEHAYEB & ASSOCIA-TES, INC. CONSULTING! ENGINEERS 3702 AZEELE ST. (813) 876-105 TAMPA, FL 33609 9977 (fax) 876-0913 ME AV aph if iL ff 1c.,arry ISSUE DATE : 09/06101 ISSUE FOR PERNT MRFPI.LJ,_9 IUTF_=jkT*N4.,L IIJG A .................................................... A .......... ............... ... ........................... A .................................................... REVISION LOG ....................... ................ T071F WST CF TPC or TWE Alafrmr. AID &14rclm %' D RLNS AID F,F££fflCAWCS CCMILY WITH TW APKCASIE hff" RXDW CCCES AW TIE AFREAM W*" WE SAFM ST40AMS AS CUtq ACOC"J," MM CWffF,S 533 AW 6W CF THE T" SI TU3,UM TO 7W R-ORCA STAWM 0. ­ 1 * 890 SANIF.01R.13, ... FL., ....... I ............... PPQECT NAME .ELIECTRIC.A.L..L.A.Y.OUT FOR OFFICE & REGISTP.-RS ............. I ............................... SHEET NAME ROJECT MMILER 9949.01 .................................... I ................ DRAWN BY. SKC/BA CHECKED BY: SC ............... I ..... I ........ ...................... SCALE. AS NOTED ............... I I ............ ....................... PLOT DATE: 9/6/01 L98M FOR 000M mom Emw b ............................ S. r__ET NUMBER 3/4" 1" CONDUIT R "TELE -POWER" POLE NOTES REAR SECTION OF TELE POWER POLE FOR POWER, FRONT SECTION FOR COMMUNICATIONS RECTANGULAR "TELE -POWER" POLE TO BE 2-1/4" x 2-1/2" (NP600 PA -2). MOUNT WITH LARGER DIMENSION OF TELE POWER POLE RUNNING BACK TO FRONT. ca i CONVEYOR DRIVE MOTOR C C 2-1/4' POLE BASE (NP600 PA) I GROMMET ED OPENIINGS TO FACE: ,'THE REAR OF THE STORE, I r REGISTER I STAND LIGHT -- (SUPPLIED BY REGISTER STAND MANUFACTURER) PREFINISHED "TELE -POWER" POLE (NP 600-10-20-1007) CONVEYOR CONTROL BOX POLE BASE (NP60Q PA) ---� (SUPPLIED BY REGISTER STAND MANUFACTURER)TO "QW" PANEL —4 1.1/16" SQUARE JUNCTION BOXES 3/4" CONDUIT --1" CONDUIT BX CABLES FROM JUNCTION BOXES THROUGH "TELE -POWER" POLE TO JUNCTION BOX IN REGISTER STAND ------POLE TOP (NP600 PA -2) (2.25" x 2.50" "TELE -POWER" POLE) X AND Y AXIS SUPPORT. (2) SP81-10X35DT TEE CLAMPS CEILING CEILING TRIM PLATE 2 E5.1 BX CABLES RUN BX CABLE FROM REGISTER STAND LIGHT TO SWITCHED LIGHT RECEPTACLE. DISPLAY STAND (SUPPLIED BY REGISTER STAND MANUFACTURER) -RUN BX CABLES FROM "TELE -POWER" POLE TO 40 JUNCTION BOX. -10 TWIST LOCK RECEPTACLE SWITCHED. (SUPPLIED BY REGISTER STAND MANUFACTL IRER) TO "CR" PANEL LIGHT SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS' PANEL. -SCANNER SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS" PANEL (DIRTY POMER)--J(DIRTY POWER) 4"x4" JUNCTION BOX (BY ELEC CONITRACTOR) (CLEAN POWER) TELEPHONE AND CONDUIT SYSTEN NI. -f 3. P,EC15'rek INSTALLATION NOTA 1. PROVIDE CONNECTION TO EACH REGISTER'S STEM MOUNTED LIGHT AND SWITCH TO CIRCUIT SHOWN. 2. MOUNT RECEPTACLE FLUSH IN THE REGISTER STAND FOR THE VISU COOLER AT THIS REGISTER. RECEPTACLE TO BE MOUNTED 1'4" A.F.F. IN THE SIDE NEAREST THE CASHIER AND ACCESSIBLE TO THE VISU COOLER PIGTAIL CONNECTION. FACE PLATE TO BE PAINTED TO MATCH REGISTER STAND COLOR. COORDINATE LOCATION WITH PREWIRED CONTROLS MOUNTED INSIDE THE REGISTER. TELEPOLE INSTALLATION NOTES: 1. CONDUITS FROM "UPS" & "CR" SHALL BE AS FOLLOWS: (4) 3/4" CONDUITS FROM PANEL "CR" -2 REGISTERS MAXIMUM. PER CONDUIT. PROVIDE ADDITIONAL CONDUITS AS REQUIRED. (2) 1" CONDUITS FROM PANEL "UPS" DEDICATED TO DIRTY POWER FOR REGISTER STAND LIGHTING, REGISTER BELT MOTOR, SENSOR-MATIC DEACTIVATION PADS & GENERAL RECEPS. 2. CASH REGISTER CIRCUITS SHALL BE PROVIDED WITH DEDICATED NEUTRAL AND GREEN ISOLATED GROUND. 3. BX CABLES SHALL BE INSTALLED WITH INSULATED THROATS AND APPROVED CONNECTORS. 4. ELECTRICAL CONTRACTOR SHALL ENSURE THAT THE TELEPOLES ARE INSTALLED SECURE AND PLUM. 5. INSTALL ADAPTER TO REGISTER STAND TOP. A HOLE IS PROVIDED IN REGISTER STAND TOP AT THE DESIRED LOCATION, THE ADAPTER MUST BE INSTALLED SO THAT POLES GROMMETED OPENING AND POWER CORD ARE FACING TOWARD THE REAR OF THE STORE. 6. "TELE -POWER" POLES CUT IN THE FIELD TO BE CUT AT THE TOP ONLY & FILED SMOOTH. 7. TO ORDER TELEPOLES, CALL WIREMOLD (1-800-338-1315), ENTER YOUR ZIP CODE. ORDER BY DRAWING NO. SP80FWP600-12DV. ORDER NO. INCLUDES POLE ADAPTER, TRIM -PLATE, (2) TEE CLAMPS, AND A 10' POWER CORD. 2" X 2" POLES TO BE PAINTED MORTON #20-1007 FURNITURE WHITE. 8, ELECTRICAL CONTRACTOR SHALL LEAVE (2) PULL STRINGS IN THE TELEPOLE (COMMUNICATION SIDE) BETWEEN REGISTERS FOR OTHERS. IN ADDITION TO PULL STRINGS OUTLINED IN POWER PLAN NOTE #1. NOTE: STAND LIGHTS PROVIDED BY GENERAL CONTRACTOR. CONTACT : SOUTHEASTERN PRODUCTS 1-800-237-3944 FOR WIRING REQUIREMENTS COOIRDINATE WITH KASH N' KARRY CONSTRUCTION MANAGER. MOUNT FIXTURES TO TELEPOLE 7'-0" A.F.F. TO FIXTURE BOTTOM. f r r I ��AdEGISTER STAND ~�\ SCANNER RUN INCOMING DIRTY POWER CIRCUIT #1 INTO SIGN JUNCTION BOX FOR CONTINUOUS POWER ON THE AD SIGN LIGHTS. THEN CONTINUE THE CIRCUIT DOWN THE "TELE -POWER" POLE TO SUPPLY THE REGISTER 4x4 JUNCTION BOX WITH POWER. GROMMETED OPENINGS IN POWER POLE -- SIGN JUNCTION BOX 4 '—AD SIGN LIGHTS--- REAR IGHTS- -REAR OF STORE NOTES G o�- I Lk— ELECTRICAL CONTRACTOR TO TERMINATE 1m THE ELECTRICAL. CONTRACTOR SHALL- DE KESPCNSIDLE FOR GROUNDING THIS POWER CORD AT THE SWITCHED THE REGISTER COMMUNICATION LOOP TO THE NEAREST COLD WATER PIPE. I 2. ELECTRICAL CONTRACTOR, SHALL SUPPLY ,SND INSTALL ALL POWERPOLE �I \\-ELECTRICAL CONTRACTOR TO TERMINATE FITTINGS ANP MOUNTING HARDWARE TO MET ALL N.E.C. REQUI6?EMENTS r� L AND MAINTAIN U.L. LISTING. U 3. ALL WORK INVOLVING INSTALLATION OF NEV, OFFICE AREA PANELS, POWER TO THE REGISTER Ab LIGHT). UNDERFLOOR DUCTS; CASH REGISTER WIRI�C, ETC< SHALL 13E CLOSELY 1 4, COORDINATED WITH REMOVAL OF EXISTING ,OFFICE AND CHECKOUTS TO A MAINTAIN STORE OPERATION. 4. COORDINATE REMOVAL AND INSTALLATION r* ALL PHONE CA.13LE3 WITH KASH N' KARRY PROJECT MANAGER, 3/4" 1" CONDUIT R "TELE -POWER" POLE NOTES REAR SECTION OF TELE POWER POLE FOR POWER, FRONT SECTION FOR COMMUNICATIONS RECTANGULAR "TELE -POWER" POLE TO BE 2-1/4" x 2-1/2" (NP600 PA -2). MOUNT WITH LARGER DIMENSION OF TELE POWER POLE RUNNING BACK TO FRONT. ca i CONVEYOR DRIVE MOTOR C C 2-1/4' POLE BASE (NP600 PA) I GROMMET ED OPENIINGS TO FACE: ,'THE REAR OF THE STORE, I r REGISTER I STAND LIGHT -- (SUPPLIED BY REGISTER STAND MANUFACTURER) PREFINISHED "TELE -POWER" POLE (NP 600-10-20-1007) CONVEYOR CONTROL BOX POLE BASE (NP60Q PA) ---� (SUPPLIED BY REGISTER STAND MANUFACTURER)TO "QW" PANEL —4 1.1/16" SQUARE JUNCTION BOXES 3/4" CONDUIT --1" CONDUIT BX CABLES FROM JUNCTION BOXES THROUGH "TELE -POWER" POLE TO JUNCTION BOX IN REGISTER STAND ------POLE TOP (NP600 PA -2) (2.25" x 2.50" "TELE -POWER" POLE) X AND Y AXIS SUPPORT. (2) SP81-10X35DT TEE CLAMPS CEILING CEILING TRIM PLATE 2 E5.1 BX CABLES RUN BX CABLE FROM REGISTER STAND LIGHT TO SWITCHED LIGHT RECEPTACLE. DISPLAY STAND (SUPPLIED BY REGISTER STAND MANUFACTURER) -RUN BX CABLES FROM "TELE -POWER" POLE TO 40 JUNCTION BOX. -10 TWIST LOCK RECEPTACLE SWITCHED. (SUPPLIED BY REGISTER STAND MANUFACTL IRER) TO "CR" PANEL LIGHT SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS' PANEL. -SCANNER SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS" PANEL (DIRTY POMER)--J(DIRTY POWER) 4"x4" JUNCTION BOX (BY ELEC CONITRACTOR) (CLEAN POWER) TELEPHONE AND CONDUIT SYSTEN NI. -f 3. P,EC15'rek INSTALLATION NOTA 1. PROVIDE CONNECTION TO EACH REGISTER'S STEM MOUNTED LIGHT AND SWITCH TO CIRCUIT SHOWN. 2. MOUNT RECEPTACLE FLUSH IN THE REGISTER STAND FOR THE VISU COOLER AT THIS REGISTER. RECEPTACLE TO BE MOUNTED 1'4" A.F.F. IN THE SIDE NEAREST THE CASHIER AND ACCESSIBLE TO THE VISU COOLER PIGTAIL CONNECTION. FACE PLATE TO BE PAINTED TO MATCH REGISTER STAND COLOR. COORDINATE LOCATION WITH PREWIRED CONTROLS MOUNTED INSIDE THE REGISTER. TELEPOLE INSTALLATION NOTES: 1. CONDUITS FROM "UPS" & "CR" SHALL BE AS FOLLOWS: (4) 3/4" CONDUITS FROM PANEL "CR" -2 REGISTERS MAXIMUM. PER CONDUIT. PROVIDE ADDITIONAL CONDUITS AS REQUIRED. (2) 1" CONDUITS FROM PANEL "UPS" DEDICATED TO DIRTY POWER FOR REGISTER STAND LIGHTING, REGISTER BELT MOTOR, SENSOR-MATIC DEACTIVATION PADS & GENERAL RECEPS. 2. CASH REGISTER CIRCUITS SHALL BE PROVIDED WITH DEDICATED NEUTRAL AND GREEN ISOLATED GROUND. 3. BX CABLES SHALL BE INSTALLED WITH INSULATED THROATS AND APPROVED CONNECTORS. 4. ELECTRICAL CONTRACTOR SHALL ENSURE THAT THE TELEPOLES ARE INSTALLED SECURE AND PLUM. 5. INSTALL ADAPTER TO REGISTER STAND TOP. A HOLE IS PROVIDED IN REGISTER STAND TOP AT THE DESIRED LOCATION, THE ADAPTER MUST BE INSTALLED SO THAT POLES GROMMETED OPENING AND POWER CORD ARE FACING TOWARD THE REAR OF THE STORE. 6. "TELE -POWER" POLES CUT IN THE FIELD TO BE CUT AT THE TOP ONLY & FILED SMOOTH. 7. TO ORDER TELEPOLES, CALL WIREMOLD (1-800-338-1315), ENTER YOUR ZIP CODE. ORDER BY DRAWING NO. SP80FWP600-12DV. ORDER NO. INCLUDES POLE ADAPTER, TRIM -PLATE, (2) TEE CLAMPS, AND A 10' POWER CORD. 2" X 2" POLES TO BE PAINTED MORTON #20-1007 FURNITURE WHITE. 8, ELECTRICAL CONTRACTOR SHALL LEAVE (2) PULL STRINGS IN THE TELEPOLE (COMMUNICATION SIDE) BETWEEN REGISTERS FOR OTHERS. IN ADDITION TO PULL STRINGS OUTLINED IN POWER PLAN NOTE #1. NOTE: STAND LIGHTS PROVIDED BY GENERAL CONTRACTOR. CONTACT : SOUTHEASTERN PRODUCTS 1-800-237-3944 FOR WIRING REQUIREMENTS COOIRDINATE WITH KASH N' KARRY CONSTRUCTION MANAGER. MOUNT FIXTURES TO TELEPOLE 7'-0" A.F.F. TO FIXTURE BOTTOM. f r r I ��AdEGISTER STAND ~�\ SCANNER RUN INCOMING DIRTY POWER CIRCUIT #1 INTO SIGN JUNCTION BOX FOR CONTINUOUS POWER ON THE AD SIGN LIGHTS. THEN CONTINUE THE CIRCUIT DOWN THE "TELE -POWER" POLE TO SUPPLY THE REGISTER 4x4 JUNCTION BOX WITH POWER. GROMMETED OPENINGS IN POWER POLE -- SIGN JUNCTION BOX 4 '—AD SIGN LIGHTS--- REAR IGHTS- -REAR OF STORE REGI,'?EE' `.',"IANp I_Ir;l_{f Wr.S. SCANNER FLEXTO "TELE -POWER" IG TWIST LOCK RECEPTACLE POLE FOR INCOMIN� SWITCHED. (SUPPLIED BY % POWER CIRCUITS. REGISTER STAND MANUFACTURER) .� TO "CR" PANEL ^.w.�. i 1 \ IGHT SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS PANEL. FLEX CONDUIT (SUPPLIED BY REGISTER STAND i I MANUFACTURER) WITH DIRTY POWER r FROM CONVEYOR CONTROL BOX. 1 SCANNER SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS" PANEL NOTES C o�- I Lk— ELECTRICAL CONTRACTOR TO TERMINATE r ` Q THIS POWER CORD AT THE SWITCHED ELEVATIONS PRIOR TO ROUGH -IN. REGISTER LIGHT RECEPTACLE. (SWITCH tV ONLY THE REGISTER NUMBER LIGHT). .FRONT OF STORE \\-ELECTRICAL CONTRACTOR TO TERMINATE AND OWNER FOR LOCATION OF ALL TELEPHONE BACK BOXES THIS POWER CIRCUIT AT THE REGISTER 4x4 JUNCTION BOX SUPPLIED BY THE U ELECTRICAL CONTRACTOR.. (CONTINUOUS UNDERGROUND CONDUITS SHALL BE 3/4" MINIMUM, UNLESS POWER TO THE REGISTER Ab LIGHT). REGI,'?EE' `.',"IANp I_Ir;l_{f Wr.S. SCANNER FLEXTO "TELE -POWER" IG TWIST LOCK RECEPTACLE POLE FOR INCOMIN� SWITCHED. (SUPPLIED BY % POWER CIRCUITS. REGISTER STAND MANUFACTURER) .� TO "CR" PANEL ^.w.�. i 1 \ IGHT SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS PANEL. FLEX CONDUIT (SUPPLIED BY REGISTER STAND i I MANUFACTURER) WITH DIRTY POWER r FROM CONVEYOR CONTROL BOX. 1 SCANNER SWITCH (SUPPLIED BY REGISTER STAND MANUFACTURER) TO "UPS" PANEL FINISHED FLOOR SECTION AT RE�ISTER NAND N.T.S. BACK OF CASH DRAWER BACK OF UTILITY DRAWER BACK OF CPU I N T E R N A T I O N A L 2709 Rc,°'Ky Point Drive, Suite 201 Tampa, Florida 33007 Tel 813281.9299 Fax 813281.9292 E—Mail apiCa)architectureplus.corn License #AAC001935 G`HEHAY B & ASSOCIATES, INC. CONSOLTINC .ENGINEERS 3702 AZEELE ST. —f �C (&3) 876-1415 11 TAMPA, FL 33609 9977 (fax) 876-0913 a ISSUE 09/06,101 ISSUE FOR PERMIT JDAS DATED F A ..................................................... A ..................................................... ........... ................ I ....... I ................. A ..................................................... REVISION LOG se f TO TFE @EST CF -RF 14""'AMGE CF TT@ ARCS LOPS Na C' = %EOF GATM WALLY NTH THE APWJ ASEF °xWa9lAA T3 UNG OCCES " THE A E FSO N HE SAFETY STA WAS TET� N ADZ NTH CIWFrms 633 Aw ew CF Tic m7 S4FFq.R4wM TO TFE FLCFIDA STATUTE. _i 9 .SANFL. ............r ................................ PPQECT NAME ............................... SHEET NAME ROACTNUMMIt DRAWN KY. SKC/BA - 9Y: SC ... .................................................. SCALE: ASTED .... ............. ..... ......... I ........ I............ PLOT DATE- 9/6/41 ISSUE FOR ..................................................... rM AN ................... I ................ ........ I ....... SHEET NUMBER J NOTES C 1. COORDINATE LOCATIONS OF ALL DEVICES WITH KASH N' KARRY PROJECT REPRESENTATIVE AND ARCHITECTURAL INTERIOR 0 ELEVATIONS PRIOR TO ROUGH -IN. 2. ELEMiCAL CONTRACTOR SHALL COORDINATE WITH G.C. AND OWNER FOR LOCATION OF ALL TELEPHONE BACK BOXES CONDUITS AND ETC. AND PROVIDE ACCORDINGLY. U 3. UNDERGROUND CONDUITS SHALL BE 3/4" MINIMUM, UNLESS OTHERWISE NOTED. 1 4, ALL EMPTY CONDUITS TERMINATING ABOVE CEILING T SPACE SHALL: a. TERMINATE IN AN ACCESSIBLE LOCATION. b. PROVIDE A 90 DEGREE BEND INTO THE CEILING SPACE: C. PROVIDE A CONNECTOR AND A PLASTIC BUSHING AT END OF CONDUIT. d. PROVIDE PULL WIRE IN CONDUIT FOR USE BY OTHERS. e. CONDUIT SHALL EXTEND INTO BAR JOISTS. 5. THESE NOTE APPLY TO ALL SHEETS. FINISHED FLOOR SECTION AT RE�ISTER NAND N.T.S. BACK OF CASH DRAWER BACK OF UTILITY DRAWER BACK OF CPU I N T E R N A T I O N A L 2709 Rc,°'Ky Point Drive, Suite 201 Tampa, Florida 33007 Tel 813281.9299 Fax 813281.9292 E—Mail apiCa)architectureplus.corn License #AAC001935 G`HEHAY B & ASSOCIATES, INC. CONSOLTINC .ENGINEERS 3702 AZEELE ST. —f �C (&3) 876-1415 11 TAMPA, FL 33609 9977 (fax) 876-0913 a ISSUE 09/06,101 ISSUE FOR PERMIT JDAS DATED F A ..................................................... A ..................................................... ........... ................ I ....... I ................. A ..................................................... REVISION LOG se f TO TFE @EST CF -RF 14""'AMGE CF TT@ ARCS LOPS Na C' = %EOF GATM WALLY NTH THE APWJ ASEF °xWa9lAA T3 UNG OCCES " THE A E FSO N HE SAFETY STA WAS TET� N ADZ NTH CIWFrms 633 Aw ew CF Tic m7 S4FFq.R4wM TO TFE FLCFIDA STATUTE. _i 9 .SANFL. ............r ................................ PPQECT NAME ............................... SHEET NAME ROACTNUMMIt DRAWN KY. SKC/BA - 9Y: SC ... .................................................. SCALE: ASTED .... ............. ..... ......... I ........ I............ PLOT DATE- 9/6/41 ISSUE FOR ..................................................... rM AN ................... I ................ ........ I ....... SHEET NUMBER J ............... ........... .. .......... ....... ............................. ................ ELI ............................ 0 ............ ry i IG (D ........... ...... ...... M SC el EX +7-6. X D-36 cc LLI EX 12 Sc. 12 EX 5 EX: sc n.4 . . ............ . .............................. DELI/BAKERY AREA 9 12 �X IG bj .............. ............... 117 _ EXISTING CASH REGISTER > RECEPTACLE AND CABLINGwf 0 TO REMAINcn U ID( . ..: i .............. . ............ IEX ................. ......... ....... EX 12 Q� ................ . . . ......... . WP D-25,27,29 EX 12 f..XS_:R9GFI DC-10 ................... 6 ....... . �RELOCATED ................ MIXER Ilk c) .... ...... ..... . . .............. ....... ................ .. .......... .................... C, ................................................. ........... cn EX EXISTING > DELI/BAKERY .............. FREEZER L_Lj............ ....................... ID -36 ............. i. sBv PDj ............ . ............. EXISTING DELI/ BAKERY COOLER - - - - - - - - - - ............. ......... ............. .......... ........... ........................ ........... D-37WP D-38,40,42,-.". +30: ................. ............... ............. ............... ............ ............... B-8 �+qe JC 8-10 ........ + 9 r> * B-33,35 .......... " ........ .......... I ................... D-8 ........... 7': .............. ............. PANEL 'D 7 EX EX ................ ANY CONFLICTS OR DISCREPANCIES BETWEEN THESE DRAWINGS AND ARCHITECTURAI LUST BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION, RESOWTIC SND DIRECTION BEFORE PROCEEDING WITH THE WORK. M* w I A A A (CUTLER HAMMER) MANUFACTURER WESTINGHOUSE EXIS-nNG PANEL 13 SPECIAL PANEL TYPE PRLI 120/208 VOLTS 3 PH. 4 WIRE/SOLID NEUTRAL 225 AMPERE BUS 225 AMPERE MAIN LUGS EX AMPERE INTERRUPTING CAPACITY MOUNTING. FLUSH X SURFACE z_ LOCATION DELI/BAKERY No. KVA ICONT. TYPE - - L T� WIRE I GND COND DESCRIPTION 50A A 8 C 20A - - - 15A 15A 15A � 15A 15A 15A 40A 1.2 40A 40A 16 .8 DESCRIPTION WIRE GND COND CONT. KVA Nb COND CONT. KVA EX EX EX RTU-D/B MIXER 3#.10 1#10 r - 1.5 2 3 - - - 1,5 4 5 10 0 NIPPLE AS REQUIRED RETARDER CONTROL EX EX EX < 0 lfr'- - 6 7 4 EX EX FX HOOD EXHAUST FAN PROOFER CONTROL 2#10 1#10 3/4' 3#10 I 1.2 8 9 40 0' 0 0 0 PROOFER CONTROL 2#10 1#10 3/4* 0 1.2 10 11 - 1.4 BAKERY CASE FANS 2#10 1#10 EX 0.5 12 131 0,8 1 - 2#10 1#10 EX BAKERY CASE LIGHTS DELI COOLER FAN COIL EX EX EX SLICER - 14 15 - 1.0 EX EX EX PREP- RECEPTACLES EXISTING EX EX EX - 16 17 0.6 - 2#10 1#10 3/4- REGISTER SENSORMATIC REGISTER SENSORMATIC 2#10 1#10 3/4* - 0.6 18 19 2.4 - 3#8 1#8 1- PROOFER #1 COFFEE EX EX EX - 17 20 21 2.4 EX EXISTING EX EX EX - 18 22 23 - EX EX EX FREEZER DRAIN HTR. SLICER EX EX EX 24 251 - EX EX EX EXISTING EXISTING EX EX EX 26 27 - - EX EX EX EXISTING 3.2 -24 28 29 - EX EX EX EXISTING EXISTING EX EX EX 30 31 - 25 EX LX u BEV. DISPENSER DELI/BAKERY LIGHTING Fx EX EX EX EX 32 33 2.4 3#13 1#8 1- PROOFER #2 DELI/BAKERY LIGHTING EX EX EX - - 34 11 35 2.4 - DELI/BAKERY LIGHTING EX EX EX - - 36 37 - - EX EX EX WRAPPER DELI/BAKERY LIGHTING EX EX EX - - 38 39 0.8 - 2#1D 1 #10 31e SERVICE COUNTER RECEPT. SERVICE COUNTER RECEPT. 2#10 1 #10 3/4' - 0.8 40 *1 0.8 35 110 1#T0 3/4- , REGISTER SENSORMATIC FREEZER/COOLER LIGHTING EX EX EX - 37 42 CONNECTED LOAD KVA +3.6 KVA SUB TOTALS I - 1+1:6: +2°0 DEMAND FACTOR 1.0 DEMAND LOAD KVA +3,6 NOTE. ALL BREAKERS 20A, UNLESS OTHERWISE NOTED, DEMAND AMPERES +10.0 El DISCONNECT AND REMOVE EXISTING CIRCUIT BREAKER. SUPPLY AND INSTAL NEW MATCHING CIRCUIT BREAKER SHOWN. NEW CIRCUIT BREAKER AIC RATING SHALL MATCH EXISTING. SUPPLY AND INSTAL MATCHING CIRCUIT BREAKER SHOWN IN EXISTING SPACE. A EXISTING WIRING TO BE DISCONNECTED FROM EXISTING CIRCUIT BREAKER AND EXTENDED TO PANEL V AND RECONNECTED TO NEW SPARE IP -20A CIRCUIT BREAKER, TO CREATE SPARE CIRCUIT BREAKER FOR CASH REGISTER CIRCUIT. 0 SENSORMATIC EQUIPMENT SHALL BE CONNECTED TO THE SAME PHASE (CUMM HAMMER) EXISTING PANEL D SPECIAL [I NEW 3P -150A SUB -FEED C/B FOR OVEN MANUFACTURER WESTINGHOUSE MANUFACTURER PRL1 120/208 VOLTS 3 PH. 4 WIRE/SOLID NEUTRAL 400 AMPERE BUS 400 AMPERE MAIN LUGS TYPE - - L T� EX AMPERE INTERRUPTING ChPACITY MOUNTING: FLUSH X SURFACE- LOCATION DELI/BAKERY No. KVA ICONT. BOX WITH WATER PROOF COVER WIRE GND COND DESCRIPTION A B C +1.4 DESCRIPTION WIRE GND COND CONT. KVA No. I 0 01 0 CD UNUSABLE SPACE UNUSABLE SPACE - - - - - 2 3 10 0 NIPPLE AS REQUIRED B UNUSABLE SPACE DELI TRACK LIGHTS < 0 lfr'- FINISHED FLOOR. - 1.4 4 FINISHED FLOOR X +1.4 40A +1.0 - +1.0 - - 3#10 I 1 #10 3/4- 40 0' 0 0 0 5 0 .0 1N SPARE DELI TRACK LIGHTS - 1.4 6 7 SUPPORTS OR KINDORF SPARE OVEN CONTROL 2#10 1#10 3/4- - 1.0 8 9 SLICER 2#10 1 #10 31e - 1.0 10 11 SPARE - - - 12 13 - - EX EX EX EXISTING - - DELI CASE HUMIDIFIER 4#10 1#10 3/4- 1.2 1 15 - - EX EX EX EXISTING DELI CASE FANS - 0.5 16 17 - EX EX EX XISF4NG DELI CASE LIGHTS - D.B 18 40A 90A 30 60A 119 3.2 EX EX EX DONUT FRYER RANGE EX EX EX 20 21 3.2 - 22 23 3.2 -24 - 25 2.3 - 1#8 1- HOT CASE -26 FRYER EX EX EX 27 2.3 --4#8 28 29 2.3 30 15A 40A +1.3 +1.8 31 - EX EX EX HOOD SUPPLY FAN BREAD SLICER 2#10 1#1Q EX 32 33 - - SPARE - - - - 34 35 - - MANTIS FLY TRAPS 2#10 1#10 3/4" - 36 37 1.3 2#10 1#10 3/4' HOLDING CABINET COMBI-OVEN 3#8 1#8 EX 3.13 38 39 1.8 3#8 1#8 1 CHICKEN WARMER 3.3 40 411 1.8 CHICKEN WARMER ......... +1.8 CONNECTED LOAD KVA +9.7 KVA SUB TOTALS 1+2_31++.21+3,2] DEMAND FACTOR 1.0 DEMAND LOAD KVA 9.7 NOTE: ALL BREAKERS 20A, UNLESS OTHERWISE NOTED, DEMAND AMPERES +26.9 SUPPLY AND INSTALL MATCHING CIRCUIT BREAKER SHOWN IN EXISTING SPACE. DISCONNECT AND REMOVE EXISTING CIRCUIT BREAKER. SUPPLY AND INSTALL NEW MATCHING CIRCUIT BREAKER SHOWN. NEW CIRCUIT BREAKER AIC RATING SHALL MATCH EXISTING. EXISTING ACTIVE 'IP -20A CIRCUIT FROM PANEL 'B' TO BE EXTENDED TO PANEL V SPARE CIRCUIT BREAKER CREATED BY ALTERATION WORK AND WRING RECONNECTED. NOTE, EXISTING CIRCUIT BREAKER IN MDP SERVICING PANEL V HAS SHUNT TRIP MECHANISM INTERLOCKED WITH DELI HOOD FIRE SUPPRESSION SYSTEM. NOTICE: ELECTRICAL CONTRACTOR SHALL VERIFY ALL EQUIPMENT, LOCATIONS, ELECTRICAL LOADS, ETC. WITH KASH N KARRY PRIOR TO START OF WORK IN THE DELI/BAKERY'.. LAYOUT SHOWN REFLECTS THE PROPOSED EQUIPMENT AT THE TIME ldigramkhOF DESIGN. LAYOUT MAY CHANGE WHEN FINAL APPROVAL IML IS GIVEN BY KASH 'N* KARRY. GENERAL NOTES TRUE NORTH 1. PROVIDE SEAL -_ITE FLEX ON ALL DELI, AND BAKERY EQUIPMENT CASES: 3 FT. (MIN.) ON FLOOR CIRCUITS AND 4 FT. (MIN.) lddwftb� I AON WALL CIRCUITS. 2. ALL RECEPTACLES AND JUNCTION BOXES IN PREP AREAS SHALL HAVE WEATHERPROOF BOXES AND COVERS (HUBBELL #WP26). ALL OTHER RECEPTACLES SHALL HAVE STAINLESS STEEL COVERS. PLAN 3. ANY EXPOSED CONDUIT IN PREP. AREAS SHALL BE SECURELY NORTH FASTENED IN PLACE AS PER CODE. NOTES P (D EXISTING EQUIPMENT AND CIRCUITING TO REMAIN. REFER TO NEW POWER PLAN SHEET E -2K FOR REWIRING OF NEW REFRIGERATED SERVICE CASES, W I -z" REWIRE NEW SCALE RECEPTACLES TO EXISTING CIRCUIT SERVING EXISTING SCALP"' E RECEPTACLES. EXTEND EXISTING WIRING AND CONDUIT AS REQUIRED AFTER NEW CASES ARE SET. NEW IG RECEPTACLES TO BE MOUNTED IN KICKPLATE OF CASE. I -A\ PROVIDE NEW WEATHERPROOF BOX WITH PHONE JACK AND BELDEN #8761 CABLE FOR DAISY CHAIN SCALE LOOP WITH 15' SLACK AT EACH SCALE LOCATION. CABLE TO BE ROUTED VIA COMMUNICATIONS COMPARTMENT OF POWERPOLES AND BACK P TO SCALE LOOP CONTROLLER IN OFFICE. EXISTING SCALE LOOP WRING TO BE REUSED L IF FEASIBLE, COORDINATE ALL WORK WITH KASH N KARRY CONSTRUCTION MANAGER. ELECTRICAL CONTRACTOR SHALL ROUTE COMMUNICATIONS CABLES AND POWER A CONDUITS FROM HUNG COLING SPACE DOWN TO MILLWORK/AND OR FLOOR BOXES N VIA PVC WIRING CHASE PROVIDED BY GENERAL CONTRACTOR. COORDINATE EXACT LOCATIONS AND PROVIDE ALL MOUNTING HARDWARE AND FITTINGS REQUIRED TO FISH CONDUITS THROUGH WRING CHASE AND SUPPORT AT TOP AND BOTTOM SECURELY. PROVIDE DOUBLE HUBBED CASTED JUNCTION BOX FOR NEW EQUIPMENT AS SHOWN ON FLOOR BOX DETAIL THIS DRAWING FOR CONNECTION TO NEW EQUIPMENT. PROVIDE SEALTITE CONNECTION TO POWERPOLE FEED OR EXISTING CONDUIT STUB -UP WITHIN CASE, COORDINATE IN FIELD. RUN NEW 3 #1/0 & 1#6 E.G. IN 2"C. FOR NEW OVEN BACK TO PANEL V AND CONNECT TO NEW 3P -150A SUB -FEED CIRCUIT BREAKER. VERIFY OVEN TYPE AND POWER REQUIREMENTS PRIOR TO ROUGH -IN. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & ENGINEER IMMEDIATELY. WIRE EQUIPMENT SHOWN TO NEW CIRCUIT BREAKER. EXISTING CONDUIT BACK TO PANEL D TO BE REUSED. EXISTING RECEPTACLE FOR RELOCATED MIXER TO BE REUSED. PROVIDE NEW SUPPORT AS M AT LOCATION SHOWN AND CONNECT TO NEW CIRCUITING. REFER TO SHEET E -2D. 10 ELECTRICAL CONTRACTOR SHALL RUN 2#10 & 1#10E.G. IN 3/4-C. FROM OVEN TO ROOF VENTILATOR FAN PER MANUFACTURER'S SPECIFICATIONS. PROVIDE AND INSTALL WEATHERPROOF DISCONNECT SWITCH FOR VENTILATOR FAN AS REQUIRED. 11 ELECTRICAL CONTRACTOR SHALL COORDINATE LOCATION OF DELI/ BAKERY CASH REGISTER LOCATION WITH KASH N KARRY CONSTRUCTION MANAGER AND PROVIDE AND PULL NEW CASH REGISTER WRING AS REQUIRED, COORDINATE WITH CENTURY DATA SYSTEMS. 12 EXISTING CONDUIT STUB -UP WITH WEATHERPROOF RECEPTACLE TO BE REUSED. A r7_11 L. I N T E R N A T 10, N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813281.9292 E -Mail api@architectureous.com Liwnse #AAC001935 CHEHAYEB & ASSOCIATES, INC. r /CONSULTING ENGINEERS 370? AZEELk ST. (8f3) 876-1416 TAMPA, FL 33609 9977 (fax) 876-0913 Aix& Ag"k 1\d�bh n Ex ACE I Arlm y ISSUE DM E : 09/06/011 ISSUE FOR PERNT OAS DATED ARRIJATK)NAL, INC. A ............... ..................................... A ..................................................... A ..................................................... 0 .......... 11 ...................... ......... REVISION LOG ............ .. .............. ...................... TORE 8= OF nE "OMMW OF IM AFOMM,40 B.'4W-M C.tV ELMS ,%NV W8C*r,AMW COWLY VM TI -E PFFD AUE W*" WUM OCAS MD TI -E APP"aE WO" FM SAFETY STA"FW AS CB� N ACCC".PU W" CWTM M AM 6W ar TW 1W &EFLROM TO ME A-Unk STATUTE R KASH r . KARRY NO. 1890 .. I ....... I ...... P.............. .................. .SANFQR.D,.. FL. .......... I ......... I ...... PRCUECT NAME .DELI/.B.AK.ERY ...... I .................. .EL.ECTRIC.A.L.. PLAN ............ SHEET NAME PROJECT NULMR 99491.01 I ......................... I ......... ................ DRAWN BY: SKC/BA CHECKED BY: SC I ................... I I ............................... SCALE: AS D'OTED . I ................................................... PLOT DA9/6/01 ........ I ; ..... ­­­ .............. ........... MW FOR ............ I ........ ...... SHEET NUMBER MOUNTING DETAIL PROVIDE DOUBLE HUBBED CAST BOX WITH WATER PROOF COVER F AND RECEPTACLE. OMIT RECEPTACLE WHEN USED AS JUNCTION BOX. L 0 0 01 0 CD R X 2M0 r U_ 0 0 10 0 NIPPLE AS REQUIRED B � �- X COUPLING FLUSH WITH < 0 lfr'- FINISHED FLOOR. 0 FINISHED FLOOR X is 0 0 IS 40 0' 0 0 0 0 .0 1N 0 A 0 0 tj 0 0 0 0 0 3/4" CONDUIT SUPPORTS OR KINDORF I N T E R N A T 10, N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813281.9299 Fax 813281.9292 E -Mail api@architectureous.com Liwnse #AAC001935 CHEHAYEB & ASSOCIATES, INC. r /CONSULTING ENGINEERS 370? AZEELk ST. (8f3) 876-1416 TAMPA, FL 33609 9977 (fax) 876-0913 Aix& Ag"k 1\d�bh n Ex ACE I Arlm y ISSUE DM E : 09/06/011 ISSUE FOR PERNT OAS DATED ARRIJATK)NAL, INC. A ............... ..................................... A ..................................................... A ..................................................... 0 .......... 11 ...................... ......... REVISION LOG ............ .. .............. ...................... TORE 8= OF nE "OMMW OF IM AFOMM,40 B.'4W-M C.tV ELMS ,%NV W8C*r,AMW COWLY VM TI -E PFFD AUE W*" WUM OCAS MD TI -E APP"aE WO" FM SAFETY STA"FW AS CB� N ACCC".PU W" CWTM M AM 6W ar TW 1W &EFLROM TO ME A-Unk STATUTE R KASH r . KARRY NO. 1890 .. I ....... I ...... P.............. .................. .SANFQR.D,.. FL. .......... I ......... I ...... PRCUECT NAME .DELI/.B.AK.ERY ...... I .................. .EL.ECTRIC.A.L.. PLAN ............ SHEET NAME PROJECT NULMR 99491.01 I ......................... I ......... ................ DRAWN BY: SKC/BA CHECKED BY: SC I ................... I I ............................... SCALE: AS D'OTED . I ................................................... PLOT DA9/6/01 ........ I ; ..... ­­­ .............. ........... MW FOR ............ I ........ ...... SHEET NUMBER o ' 0 Cu Q LC, &i " co N C-) CD (n aT UKAWING NO FES: O CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF WATER AND CONNECT TO EXISTING AS REQUIRED. CONTRACTOR SHALL INSTALL NEW SHUT—OFF VALVE ON STUB FROM EXISTING PIPING. O CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF SANITARY PIPING AND CONNECT TO EXISTING AS REQUIRED. O CONTRACTOR TO REMOVE EXISITING FIXTURE AND DISPOSE OF AS DIRECTED BY THE OWNER. IT IS THE CONTRACTOR'S RESPONSIBILITY TO ADJUST EXISTING PLUMBING TO ACCOMMODATE NEW FIXTURES. O4 REMOVE EXISTING FIXTURE, CLEAN, REFURBISH AND REINSTALL FIXTURE IN SAME LOCATION. PROVIDE ALL REQUIRED MATERIAL DUE TO NEW TILE. U5 INSTALL NEW FLOOR DRAIN IN EXISTING LOCATION. COORDINATE HEIGHT WITH NEW TILE FLOOR. © REMOVE EXISTING HUB DRAIN AND PLUG AND CAP B.F.F. PATCH FLOOR TO MATCH EXISTING. O7 MODIFY LOCATION OF EXISTING HUB DRAINS AS REQUIRED TO ACCOMMODATE NEW FIXTURES. FLOOR PLAN — PLUMBING SCALE: 3/32"=1'-0" 9399.01 O MODIFY LOCATION OF EXISTING REFRIGERATION PITS AND PIPING AS REQUIRED TO ACCOMMODATE NEW CASES O9 REFURBISH AND REINSTALL EXISTING FIXTURE IN NEW LOCATION CUT AND PATCH CONCRETE TO MATCH EXISTING. 10 EXTEND AND MAKE NEW CONNECTION TO EXISTING HOT AND COLD WATER AND VENT PIPING. VERIFY LOCATION. W-5 TRUE NORTH MATERIAL SPECIFICATIONS: 111D 1. DOMESTIC HOT AND COLD WATER PIPING SHALL BE TYPE "L" COPPER WITH WROUGHT COPPER FITTINGS. PL,4N 2. SANITARY WASTE AND VENT PIPING SHALL MATCH EXISTING. NORTH 3. INSULATION SHALL BE FLEXIBLE UNICELLULAR—SELF—SEAL ARMAFLEX 2000 1/2 - THICK /2"THICK FOR HOT WATER PIPING UP TO 2" SIZE — PROVIDE SHEET METAL SADDLES AT EACH HANGER. PLUMBING GENERAL NOTES: • ALL WORK SHALL COMPLY WITH APPLICABLE NATIONAL, STATE, AND LOCAL CODES. THIS SHALL INCLUDE, BUT NOT BE LIMITED TO, THE STANDARD PLUMBING CODE. • THE PLUMBING SUBCONTRACTOR SHALL FURNISH AND INSTALL ALL PLUMBING FIXTURES, UNLESS NOTED OTHERWISE. I • THE PLUMBING SUBCONTRACTOR SHALL INSTALL AND MAKE ALL PLUMBING CONNECTIONS TO OWNER FURNISHED EQUIPMENT. • REVIEW PLANS OF ALL TRADES PRIOR TO BIDDING AND INSTALLATION TO INCLUDE ALL PLUMBING FOR COMPLETE SYSTEMS SHOWN ON THE PLANS AND AS REQUIRED. • VERIFY MOUNTING HEIGHT AND WATER CONNECTION SIZES TO ALL PLUMBING FIXTURES PRIOR TO ROUGH—IN. FURNISH CUT—OUT TEMPLATES, FOR PLUMBING FIXTURES TO BE INSTALLED IN MILLWORK, TO THE GENERAL CONTRACTOR. • COORDINATE WITH OTHER TRADES TO PREVENT INTERFERENCE WITH HVAC DUCTS, STRUCTURE, ELECTRICAL LIGHTING, AND OTHER PIPING IN THE CEILING SPACE. VENT PIPING AND WATER PIPING SHALL BE HELD EITHER ABOVE OR BELOW HVAC DUCTWORK AS COORDINATED WITH THE HVAC CONTRACTOR. • ALL WORK, BOTH MATERIAL AND INSTALLATION, SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM ACCEPTANCE BY THE OWNER. • ALL CHANGES SHALL BE APPROVED BY THE ARCHITECT. • COORDINATE WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING—IN PLUMBING FIXTURES AND EQUIPMENT SUPPLIES. • MAKE PROPER HOT AND COLD WATER, WASTE AND VENT PIPING CONNECTIONS TO ALL FIXTURES AND EQUIPMENT EVEN THOUGH ALL FITTINGS AND CONNECTIONS ARE NOT SHOWN. • CONTRACTOR TO FIELD VERIFY EXACT LOCATION AND DIRECTION OF SANITARY, WATER AND VENT PIPING. CONTRACTOR TO CONNECT AS REQUIRED TO EXISTING PIPING. • CONTRACTOR TO REPAIR DAMAGED WALL AND/OR FLOOR DUE TO REMOVAL AND/OR REPLACEMENT OF PLUMBING FIXTURES. CONTRACTOR'S RESPONSIBILITY TO CUT AND PATCH AREA TO MATCH EXISTING. • PROVIDE TRAP PRIMERS FOR FLOOR DRAINS, FROM THE NEAREST LAVATORY, AS SHOWN ON THE PLAN AND AS REQUIRED BY LOCAL CODE. PRIMERS SHALL BE LOCATED IN A SERVICABLE LOCATION AND INSTALLED PER MANUFACTURERS INSTALLATION INSTRUCTIONS. • PLUMBING CONTRACTOR SHALL SUPPLY AND INSTALL HUB SCREENS IN ALL VISIBLE HUB DRAINS. • IT IS IN THE INTENTION OF THESE DRAWINGS TO COVER ALL WORK AND MATERIAL FOR A FIRST CLASS INSTALLATION. ANY EQUIPMENT, PLUMBING FIXTURE, TRIM HARDWARE AND/OR DEVICES USUALLY UTILIZED IN THE CLASS OF WORK, THOUGH NOT SPECIFICALLY MENTIONED OR SHOWN ON THESE DRAWINGS, BUT WHICH MAY BE NECESSARY FOR THE SATISFACTORY COMPLETION OF THE WORK (AS DETERMINED BY THE ARCHITECT) SHALL BE FURNISHED AND INSTALLED BY THE CONTRACTOR AS PART OF HIS TOTAL WORK 4 I i O FD 4 11 _ `io o�° ii O FDO i EXTG. MEN'S RM. EXTG. WOMEN'S RM. ®Ial ou C Iului C� P-1 SEE SHEET P1.2 FOR 3 FIXTURE SCHEDULE I � I I PARTIAL FLOOR PLAN — PLUMBING SCALE: 1/4"=l'—O" 9399.01 PLUMBING LEGEND DESCRIPTION ABBREV. SYMBOL SANITARY PIPING SAN VENT PIPING V -------- COLD WATER PIPING CW — — HOT WATER PIPING HW — — — — CLEAN OUT CO FLOOR DRAIN FD TYPICAL (TYP) EXISTING PIPING TO REMAIN CONNECTION BETWEEN NEW AND EXISTING BELOW FINISHED FLOOR B.F.F A RCHIT[CTUR[ [US I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813281.9292 E—Mail api@architectureplus.com License #AAC001935 Engineering Professionals, Inc. Mechanical Engineers EB -0006437 1720 W. Cleveland Street — Suite E Tampa, FL 33606 (813) 251-6848 PrA bash n' Karry ®AS DATED ARCHITECTUREPLUS INTERiNATIONAL, INC. O 0 ..................................................... REVISION LOG STATE REGISTRATIONS F L... #.AO01935............................................... ..................................................... ./ .............................................. 4*91-Mot GARY G. STENLUND, P.E. REGM0439 FL. ................................. ........ TO TFE BEST CF THE IQJdMFDGE CF THE PAST-fiECTS MD DU4EEFa SAD R_M!S MID SPECFTCATM COMPLY WTFH THE APPLICABLE MINMUM BULDW CODES AND TFE APPLICABLE MWN FFE SAFETY STAALWUS. FOOD LION NO. 1890 ..................................................... SANFORD... FL. ........................ PROJECT NAME FLOOR PLAN PLUMBING.................................................. SHEET NAME PRMCT NUMBM 9449.01 ..................................................... DRAWN BY: FWH CHECKED BY. GGS ..................................................... SCALE: AS NOTED ..................................................... ISSN DATE 9/6/01 ISSN FOFt BID/PERMIT . . .. . .... . .. . .... . ... . P101 ..................................................... SHEET NUMBER CD 0 OU Cu (, ma Co r-, Cu a a� ALL REFRIGERATED DELI SERVICE CASES, PROVIDE A 60 Psi REGULATOR AND DOUBLE CHECK VALVE AND INSTALL ON ALL LINE FEEDS TO HUMIDIFIER. EXIST 1/2" CW UP FROM — SLAB. VERIFY LOCATION. — W (P lli U W Z EX. HD TO BE RELOCATED AS SHOWN. Q Q O i_ L— - - _-- _ - _ --- _L- - ENLARGED DELI/BAKERY FLOOR PLAN SCALE: 3/16"=1'-0" 9399 NOTE: CONTRACTOR SHALL REPLACE THE EXISTING HUB DRAIN IF THE EXISTING IS NOT SUITABLE FOR REUSE. DRAWING NOTES: O1 CONTRACTOR TO FIELD VERIFY EXACT LOCATION OF WATER ANID CONNECT TO EXISTING AS REQUIRED. CONTRACTOR SHALL INSTALL SHUT—OFF VALVE ON STUB FROM EXISTING PIPING. O2 PROVIDE NEW OR MODIFY LOCATION OF EXISTING HUB DRAINS OR CONDENSATE PIPING AS REQUIRED TO ACCOMODATE NEW CASES. VERIFY LOCATION OF EXISTING SANITARY. CUT AND PATCH FLOOR TO MATCH EXISTING. CASE MIN. DISTANCE AIR GAP BETWEEN CASE OUTLET AND COND. DRAIN I—��---CO)ND. DRAIN BY OF 18" i i REFRIGERATION SUIBCONTRACTOR L------------- ----------------� FLOOR 4"X3" REDUCER FITTING 3" DEEP SEAL TRAP NOTE: PROVIDE 3/8" ARMAFLEX INSULATION ON ALL DRAINS FROM PRODUCE CASES. CASE CONDENSATE DRAIN DETAIL NO SCALE / I o EAP Hui INc N URAiN S Nk P'2 3 SANK MP 30 3 is NE p ASN �u6 NEW 3" HUB DRAIN O LO N NEW 3" HUB DRAIN R�LO� coMp % SJNk / U PLO c R Fk�STI ORAIN loon c ORAIN SANITARY RISER DIAGRAM 1 NO SCALE P1.2 NEW Nie 0 RAIN I SANITARY RISER DIAGRAM 3 NO SCALE P1.2 UN% NO SCALE P1 2 PLUMBING FIXTURE SCHEDULE: P-1: ELECTRIC WATER COOLER — OASIS #PBAMSL, SPLIT LEVEL, STAINLESS STEEL TOP, 8.0 GPH. MOUNT ONE WITH SPOUT 030" A.F.F. AND ONE WITH SPOUT @36" A.F.F. PROVIDE FLOOR MOUNT CARRIER. NO SUBSTITUTIONS. P-2: 3—COMPARTMENT SINK — PROVIDE STOPS, SUPPLIES, TRAP, ETC., MAKE FINAL CONNECTIONS TO OWNER FURNISHED SINK. 1/2" CW, 1/2" HW, 2" VENT, 2" SAN. FD: FLOOR DRAIN — JOSAM #30000—A, 6" STRAINER, NIKALOY TOP. MATCH TO PIPE SIZE. FS: FLOOR SINK — JOSAM #49060, 12x12" NIKALOY TOP, 10" DEEP, ACID—RESISTING INTERIOR DRAINAGE FLANGE WITH WEEPHOLES. PROVIDE 1/2" GRATE. MATCH TO PIPE SIZE. ARCHITE"CTUR[ [U5 I N T E R N A T 1 0 N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813,281,9292 E—Mail api@architectureplus.com License #AAC001935 Engineering Professionals, lnc. Mechanical Engineers EB -0006437 1720 W. Cleveland Street — Suite E Tampa, FL 33606 (813) 251-6848 P' bash n' harry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. ..................................................... 0 ..................................................... REVISION LOG STATE REGISTRATIONS ..................................................... FL #AA001935 ..................................................... ..................................................... ............................... I..................... 41'�111,077%/ GARY G. STENLUND, P.E. R 043 FL. ' R TO Tl -E P,ES! CF THE fQdOYILECC-E CF THE AAZI I TS AND EW-JgM r, SAD _PMS PIVD' %rEC ATM COMILY Mli THE APDL CPRE MM" BUDW CCCES APD TF E APPLICABLE MMf" RV= SAFETY STANUMM. FOOD. LION .. NO... 18.90 .. , .. , . . SANFORD... FL. ........................ PROJECT NAME ENLARGED FLOOR PLAN ..................................................... ..................................................... SHEET NAME PROSECT Nt� 9449.01 .................... DRAWN BY: FWH CHECKED BY: GGS ..................................................... SCALE: AS NOTED ..................................................... ISSIE DATE: 9/6/01 ..................................................... MM FOR BID/PERMIT ..................................................... ................ P.1.■ ........................... SHEET NUMBER 39 M GP TRUE:: NOR Tr -1 PLAN NORTH EQUIPMENT ROOM �� 21 EXISTING DUCTWORK TO REMAIN — SIZE. I AS INDICATED. FIRST DIMENSION IS FACE OF DUCT SHOWN ON PLAN, EXISTING DUCTWORK TO BE REMOVED. r a i MOD 4 5 VOLUME DAMPER 39 M GP TRUE:: NOR Tr -1 PLAN NORTH EQUIPMENT ROOM �� 21 SYMBOL. LEGEND (B)SD SMOKE DETECTOR GRH RELATIVE HUMIDITY (ST TEMPERATURE QS P AIR PRESSURE SWITCH (1) THERMOSTAT(S)AS DISCHARGE AIR SENSOR NOTE: ALL EXISTING SENSORS, CONTROLS, WIRING, ETC. SHALL BE REMOVED UNLESS SPECIFICALLY INDICATED OTHERWISE. SENSOR LEGEND AHU AIR HANDLING UNIT A.F.F. ABOVE FINISHED FLOOR O.A. OUTSIDE AIR S.A. SUPPLY AIR R.A. RETURN AIR RTU ROOFTOP UNIT (AIR CONDITIONING) ABBREVIATIONS 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WITH DEMOLITION WORK. 2. DIFFUSERS, GRILLES, DAMPERS, DUCT HEATERS, FANS, ETC. SHALL BE SALVAGED AS INDICATED ON PLAN FROM AREAS SCHEDULED FOR DEMOLITION, SALVAGED EQUIPMENT MAY BE REUSED OR RELOCATED WHEN INDICATED ON SHEET M-2. UNUSED ITEMS SHALL BE RETURNED TO FOOD LION, INC. 3. EXISTING AIR HANDLING UNIT AHU-1 TO REMAIN. COILS, REFRIGERANT PIPING, AND ROOFTOP CONDENSING UNIT SHALL BE REUSED OR REPLACED AS INDICATED ON SHEET M-2, 4. COMPLETELY REMOVE EXISTING KITCHEN EXHAUST HOOD No. 2. � MECHANICAL DEMOLITION PLAN r;; � 1 (DEMOLITION NOTES ARCHIT[CTUR[ [US INTERN ATI 0 NAL 2709 Rocky Point Drive, Suite 201 Tampa, Horida 33607 Tel 813.281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com a B OWERS CONSULTING, PA C ONS ULTING ENGINEERS { 1425 JAKE ALEXANDER BLVD. SOUTH — SUITE B PO BOX 1711 (28145) SALISBURY, NC 28146 PHONE:(704)630-0075 FAX:(704)630-0051 EMAIL•bowers®vnet.net CERTIFICATE OF AUTHORIZATION #8458 P, Kash.n' Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Al7/19/01 FLOOR PLAN REVISION 02 9/04/01 FOOD LION COMMENTS ........................................... REVISION LOG STATE REGISTRATIONS N,C„#85,81, y T6 'THE BEST OFTHEKNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY MATH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. Kash, N,', K,a,r,r,y... N,o,,,,1,8,90 SAN FORDt...F�....................... PROJECT NAME M,ECH,AN,I,CAL......................... D E M O,L I, T I, 0 N ........................... . SHEET NAME PROJECT NUMBER: 9949,00 DRAWN BY: MDB CHECKED BY: MDB SCALE: AS NOTED ............ . .......... . . ... ISSUE DATE; 9/27/01 ISSUE FOR: PERMIT SHEET NUMBER i EXISTING DUCTWORK TO REMAIN — SIZE. 20x20 AS INDICATED. FIRST DIMENSION IS FACE OF DUCT SHOWN ON PLAN, EXISTING DUCTWORK TO BE REMOVED. SALVAGE DIFFUSERS AND/OR GRILLES FOR RE—USE/RELOCATION. SEE SHEET M-2. MOTOR OPERATED DAMPER MOD tt� VOLUME DAMPER VD 8 LIMIT OF REMOVED AND/OR ABANDONED DUCTWORK SYMBOL. LEGEND (B)SD SMOKE DETECTOR GRH RELATIVE HUMIDITY (ST TEMPERATURE QS P AIR PRESSURE SWITCH (1) THERMOSTAT(S)AS DISCHARGE AIR SENSOR NOTE: ALL EXISTING SENSORS, CONTROLS, WIRING, ETC. SHALL BE REMOVED UNLESS SPECIFICALLY INDICATED OTHERWISE. SENSOR LEGEND AHU AIR HANDLING UNIT A.F.F. ABOVE FINISHED FLOOR O.A. OUTSIDE AIR S.A. SUPPLY AIR R.A. RETURN AIR RTU ROOFTOP UNIT (AIR CONDITIONING) ABBREVIATIONS 1. CONTRACTOR SHALL VERIFY EXISTING CONDITIONS PRIOR TO COMMENCING WITH DEMOLITION WORK. 2. DIFFUSERS, GRILLES, DAMPERS, DUCT HEATERS, FANS, ETC. SHALL BE SALVAGED AS INDICATED ON PLAN FROM AREAS SCHEDULED FOR DEMOLITION, SALVAGED EQUIPMENT MAY BE REUSED OR RELOCATED WHEN INDICATED ON SHEET M-2. UNUSED ITEMS SHALL BE RETURNED TO FOOD LION, INC. 3. EXISTING AIR HANDLING UNIT AHU-1 TO REMAIN. COILS, REFRIGERANT PIPING, AND ROOFTOP CONDENSING UNIT SHALL BE REUSED OR REPLACED AS INDICATED ON SHEET M-2, 4. COMPLETELY REMOVE EXISTING KITCHEN EXHAUST HOOD No. 2. � MECHANICAL DEMOLITION PLAN r;; � 1 (DEMOLITION NOTES ARCHIT[CTUR[ [US INTERN ATI 0 NAL 2709 Rocky Point Drive, Suite 201 Tampa, Horida 33607 Tel 813.281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com a B OWERS CONSULTING, PA C ONS ULTING ENGINEERS { 1425 JAKE ALEXANDER BLVD. SOUTH — SUITE B PO BOX 1711 (28145) SALISBURY, NC 28146 PHONE:(704)630-0075 FAX:(704)630-0051 EMAIL•bowers®vnet.net CERTIFICATE OF AUTHORIZATION #8458 P, Kash.n' Karry OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Al7/19/01 FLOOR PLAN REVISION 02 9/04/01 FOOD LION COMMENTS ........................................... REVISION LOG STATE REGISTRATIONS N,C„#85,81, y T6 'THE BEST OFTHEKNOWLEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY MATH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPLICABLE MINIMUM FIRE SAFETY STANDARDS. Kash, N,', K,a,r,r,y... N,o,,,,1,8,90 SAN FORDt...F�....................... PROJECT NAME M,ECH,AN,I,CAL......................... D E M O,L I, T I, 0 N ........................... . SHEET NAME PROJECT NUMBER: 9949,00 DRAWN BY: MDB CHECKED BY: MDB SCALE: AS NOTED ............ . .......... . . ... ISSUE DATE; 9/27/01 ISSUE FOR: PERMIT SHEET NUMBER i 1, THE EXISTING CONDITIONS PLAN ON THIS SHEET IS INTENDED TO CONVEY THE APPROXIMATE CONDITIONS OF THE BUILDING. ALL DATA SHALL BE VERIFIED BY THE CONTRACTOR PRIOR TO THE SUBMISSION OF BIDS AND/OR THE COMMENCEMENT OF WORK, ANY CONDITIONS WHICH DIFFER SUBSTANTIALLY FROM THAT INDICATED ON THE EXISTING CONDITIONS PLAN OR THE CONSTRUCTION DOCUMENTS, SHALL BE IMMEDIATELY BROUGHT TO THE ATTENTION OF THE ARCHITECT. GENERAL NOTES SENSOR LEGEND ABBREVIATIONS TRUE PLAIN NORTH NORTH � EQUIPMENT ROOM �� 2 � �� NEW DUCTWORK -SIZE AS INDICATED T ;; I I I ; FIRST DIMENSION IS FACE OF DUCT EXTG, PRODUCE PREP. RIM. II I i SHOWN ON PLAN, �� I I EXISTING DUCTWORK RE -USED IN PLACE. �ry �I II I I I C i 715 C ! 715 4�1------ I I n 715 I I 715 --------- I ---- I It I I �_--- 140_-_-1 ' I _ 140 _�® I I DUCT OGEE (UP IN DIRECTION INDICATED) II ELECTRIC DUCT HEATER EXISTING STORAGE FREEZER TING PRODUCE COOLEREDHEXIS40�%� I ii IoI I I I_NI_ _ __ _ ____ _ _ �__ _�__ .__ _�_____ _ ___ _____ - ___�_. __ __ ____ __ ._____ _� _ _r__�_ MOTOR OPERATED DAMPER I " 2670 - I I I I MOD (NEW OR EXISTING AS INDICATED) I ------------- JJ I I ISI 221 _ /1 I I --- ---1-� __ I o I I------------ I/ I I I F267�0VOLUME DAMPER I - -IL J I I, I I I I;-- i ---- I I EXISTING MEAT COOLER 715 �'¢_-- C I I ( I ® NEW SUPPLY DIFFUSER II MI:f4-0 I I 2670 12x12 UP TO EF -6 I IL- II LLi I I I I C ®R RE-USED/RELOCATED EXISTING DIFFUSER I I --r-----------.571 I I C C I I l 3- 220 - - - - - - - I/ I I I I 2670 I 715 11 715 (; D I� I _ I I C N I _ _ _ _ 715 ; ; NEW RETURN GRILLE 800 I " II �� I I 14 I Z---_-_140-_-_-_-_ _ 140 - � - - - - - - - - - - ® ® - _ ® RELOCATE EXISTING RELOCATE EXISTING FLY FAN _ --- -- - -, _ 1 I it 220_ - - _ _ - - - I / I I - - - 715 I I SENSOR - MOUNT TO CEILINGCONNECT TO EXISTING r I! ISI I I I I /"I I - `tel M _ SII ---'"� •---- [� _„� �� jt ' III I ®5I -----I II Q ISI IIII Ii Ii 7A15 i i 4 UNDERCUT DOOR5236 7 FF-3 II 140 NFF-1 __ - - - - ------- -- - - EXISTING EUH TO REMAIN-/y-----ri5 C-4 -T- 21 -----i 2670 ( 2 14x14 ;; ; ; I 10x10 UP TO I ri-I ------------ ,8x,8 ---- "' - ------ SYMBOL LEGEND ,--- EF -3 TO REMAIN I II ' _,- , I I ''I I I I I EDH-1 Z I I I I " ' 220 - I / I I I L2��70 _ _-_ ,3.7 1. M.C. SHALL FIELD VERIFY ALL EXISTING CONDITIONS AT THE JOB SITE PRIOR TO ---r--------- - - -- ---I-------L/ J I I I _I EXISTING RECEIVING Ronrj �_ —lr--=-I�-�--==--I -,- .-._ _.____ _ _ _ _._.._ _. __.__ __ __ _._._ . __ _ _ __ __ _ ____ -- -- I - - ---- -- --I-I - - -- -- l -r-{-- - -- I �- - BEGINNING WORK. NOTIFY Kash N' Karry OF ANY DISCREPANCIES, ��� I II II1!t1I i� � MT. FzzH. E�II � II „iiii r, 715 IIIS�I L(,�p 2. DUCT SYSTEMS SHALL BE CONSTRUCTED IN ACCORDANCE WITH LATEST SMACNA FAT I 4_4_______ X(O. ® I[2:C670 STANDARDS WITH LIMITATIONS AS NOTED BELOW OR IN SPECIFICATIONS. ALL I ® _ _ ® DUCTWORK SHALL BE CONSTRUCTED TOA 1 PRESSURE CLASS, C-14 1 --___ -r� I I X 1 1o 220 1 I �7O 7 7 _ _________ l_-4 A 3, ALL DUCTWORK WITH A WIDTH DIMENSION OF 46 OR LARGER S HALL BE C1B0 ELECTRICAL I - - - - - - - - - - - - - 40- 4i0---- _X4_I® SUPPORTED WITH TRAPEZE TYPE HANGERS AS INDICATED PER DETAILS O N Rn�n- I _ _ _ _ 22� 715 SHEET M-3, SUPPORTS SHALL BE ATTACHED TO DUCTWORK PRIOR TO _ _ _ _ _ _ _ / I 800 I I I I L_J i i J I I �, I I EXISTING VESTIBULE I I I I I I _ 3.1 APPLICATION OF EXTERNAL INSULATION. INSULATION SHALL BE APPLIED TO �� 715 --------------- '��— COMPLETELY COVER DUCTWORK AND SUPPORTS. I I i I I M2O L0 I I - --�� --- - ------ ---- -._ ___ .._ L____ _ ___ __. _ _�____. _- .—_- -._-_ .- ----- _ ._—•- - --_l__ I ___- _ .A—_ _. _ _ �„�- __ _ -- -- -- f --,—t --- � 4, DUCTS CONNECTING TO NEW AND/OR RELOCATED DIFFUSERS SHALL BE INLET FF -4 I I I I I I II i i I I SIZE OF DIFFUSER. PROVIDE VOLUME DAMPER FOR BRANCH TAKEOFF AS FF -5 iXi I I 44✓= — - I 11 7C5 I I I I I I INDICATED ON PLAN. SEE DETAILS ON SHEET M-3, I i — ,I00 N z I�I I I I I I I I M15 5, ALL LONGITUDINAL SEAMS AND NON-GASKETED TRANSVERSE JOINTS SHALL BE X I I -�I I I I I EXTERNALLY SEALED WITH HIGH PRESSURE DUCT SEALER BY UNITED McGILL OR +I C i8x10 E ' 81 �Y I I I _ _ _ _ _ - - - - - a M EQUAL,. SEALER SHALL . BE APPLIED BY M.C. AND APPROVED BY Kash N Karry I I _ I li 715 00 - -r----- __17 -7-----Y,r= „ ( L I X j- - 500 I I REPRESENTATIVE BEFORE DUCT INSULATION IS INSTALLED. I I - II I---------� I N I SII - xE f� I II 2020 150 I II ® 141 I I /� loxton 6, ALL NEW DUCT SIZES SHOWN ARE "INSIDE -CLEAR" DIMENSIONS. ALL NEW I SoCo I I r— u�P it C C I I /' RTU -DB TO ®ExsR EF -4 500 I DUCTWORK SHALL HAVE 2", 3/4 PCF, EXTERNALLY WRAPPED INSULATION WITH I i I �_ - I, 715 715 I I , REMAIN I c ��E �___ - __.� VAPOR BARRIER SEE SPECIFICATIONS . ROUTE ALL NEW DUCTWORK AS TIGHT _ �_._ _ m �._ _. __. ._I ._.___..._ _.__._.__. __ .__.___ _ .__ ____ __-_ -_ .___ :._,, . _ _._ _ _ __ _ _ _ .._ -too - - _ _- ( ) 1 20 0�� - EXISTING DAIRY CCCLER II I I I I �;--------= � _ - __ _ _� - - `�� TO ROOF JOISTS AS PRACTICAL, COORDINATE ROUTING TO AVOID CONFLICTS I I ® I I r �+ r 7L � -) WITH OTHER TRADES. _ AHU-1 I+ �I I I -_I C ---- II EDH-1 \f'I I^I I Ic i �'r 1-- -I I II ,, i I I � i � H I I I ;I I/ I 11/1 IXI 1 F �I I ! i I I I --- I-�1------------=-` -�T I I ; II /L_J-� J EXISTING D/B + 7. FLEXIBLE DUCT MAY BE USED AT END OF RUNOUTS IN LENGTHS NOT I--- i II � _--------- (------ --------------I r/ II COOLER 200i- - T T , +, C 121- I I EXCEEDING 4'-0". INSTALL PER SMACNA STANDARDS (SEE SPECIFICATIONS). I I I / I I r l I( i i I I 72x28 I I 44x28 I I I 36x28 I_ ' PC TRAININL' RM 2250 �\ ,�-- /18xT8- I 1 II I I -- I . I _ _ 8. PROVIDE 90' METAL 24 GA. MINIMUM DUCT ELBOW WITH 4 PIECE GORE AT i I I---j=�'------(-- � � I � I I �� I �*I u C KH -1 TO REMAIN � � '� _ ®� ALL NEW CEILING DIFFUSER/GRI LLE -TO -FLEX DUCT CONNECTIONS, I �- - - - - J iI I II— - - -I-I — - -I-I - -I-I— .-1-1- - 1--1-- - •I -I ----- I -I- - -� -�- C I -N E- Soo- - ��_--_--�_s1 800 OA DUCT UP TO I--r�-- I I I I I I I I I I I I I I I I I 600 I I®� 32x18 GOOSENECK 10x10 UP TO I u e e e ISI i� 121 I I 100 ® _I ON ROOF TO REMAIN II C I I ISI ISI ISI ISI ISI ISI I �� C_ 9, M.C. SHALL VERIFY SIZE OF EXISTING DUCTWORK SCHEDULED TO REMAIN. INTERMEWNG ROOM I I ( EF -2 TC I! ® I I I' I H I' I 1= I I�I N I -I I ,I ; ; EQUIPMENT OPENINGS AS REQUIRED FOR PROPER CONNECTION OF NEW TO REMAIN I, 715 I I I I I I I I I I i i i 120 r T� R l i EXISTING. w H I ® I ® ® I I CJI I + ISI I I I I I I I I � ; I I I -- T�_ L� J I I SEXISTING D B I C I I I I ; II I I I 10, M.C. SHALL INSPECT AND REPAIR DUCTWORK AS REQUIRED TO PROVIDE A TIGHT TORAGE g OM I ``I C I I I I I C 1 1 C \\ I „ DELI/BAKERY AREA I I C \' C I I = 6� I I I� I I I I I 715 I I 715 I I 715 \\ LI I I I I I KH -1 I I AIR DISTRIBUTION SYSTEM, M.C. SHALL CAP AND INSULATE ALL OPEN DUCT 250 I , ,l 600 L_ I I TERMINATIONS AND OTHER OPENINGS IN EXISTING DUCTWORK DIRECTLY ____II_ __ I I I I I I , n I�I ,, -------- - I --- -I I II x DEMOLITION. LL SUPPLY D E URN I II IL II 20x�8_-_it_ __"24x24I I I + + RESULTING FROM OR INCIDENTAL TOA AN R T7EDH- 3� --ii -Igl I I I I I I I; 121 OUTLETS SHALL BE BALANCED TO THE AIR FLOW QUANTITIES SHOWN ON MEN'S RM., II I I I I -------® SoowGMEN's RM. I C DRAWINGS. (0 11IISI I I+ I II I Fj­ �I C® C® C C C® C® u-- II I I I I ;; 600 11. M.C. SHALL PROVIDE PREFABRICATED ROOF CURBS FOR INSTALLATION BY G.C. I ATG. ICE UZFAIA FREEZER 715 715 715 715 715 715 --1 �^ G.C. SHALL PROVIDE AND INSTALL ALL FIELD FABRICATED MECHANICAL CURBS EF -D TO REMAIN l _ I I _ -� II j ,! Exlsnlvc D/e ; ; AND PROVIDE FLASH INS TO ROOF SURFACE AS REQUIRED FOR WATERTIGHT C -- H �+ II FREEZER I I INSTALLATION AT ALL NEW OR MODIFIED MECHANICAL ROOF PENETRATIONS. G.C. EXISTING CORRIDOR #2 +I 6x6 U TO ROOF „ I I 100 ! ! CAP�T0 REMAIN II SHALL REPAIR ALL ROOF AND/OR WALL OPENINGS RESULTING FROM ' I I MECHANICAL PENETRATIONS REMOVED DURING DEMOLITION. EXTO. SECURITY ROOM L ------- r- I i 12, M.C. SHALL COORDINATE ALL WORK WITH OTHER TRADES TO AVOID CONFLICTS. I I —-- (� 13. COORDINATE ALL DIFFUSER AND GRILLE LOCATIONS WITH CEILING GRID AS I i i I SHOWN ON ARCHITECTURAL DRAWINGS. i — 10x10 FROM OVEN ! UP TO EF -5 ON ROOF 14, M.C. TO COORDINATE DUCTWORK SIZES WITH CLEARANCES ABOVE CEILING. M.C. SEE SHEET M-3 FOR TO NOTIFY PROPER Kash N' Karry REPRESENTATIVE OF ANY CONFLICTS. F 5 rSCHEDULE AND DETAILJ F3 A. p . 4)(E)��,,,/ ` _ � ✓ 15. REFER TO SPECIFICATIONS, DIVISION 15 SECTIONS FOR ADDITIONAL MECHANICAL REQUIREMENTS, MECHANICAL - FLOOR PLAN 3/32`=1'-O` SCALE 1 RENOVATION NOTES ARCHITICTUR[ [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813,281.9292 E—Mail api@architectureplus.com ® BOWERS C ONS ULTING, PA C ONS ULTING ENGINEERS 1425 JAKE ALEXANDER BLVD. SOUTH - SUITE B J. PO BOX 1711 (28145) SALISBURY, NC 28146 PHONE: (704)630-0075 FAX:(704)630-0051 EMAIL:bowers®vnet.net CERTIFICATE, OF AUTHORIZATION #8458 F Dash n' OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Zh 7/19/01 FLOOR PLAN REVISION Zj, AHU AIR HANDLING UNIT QS SD SMOKE DETECTOR QS RH RELATIVE HUMIDITY A. F. F. ABOVE FINISHED FLOOR (S)T TEMPERATURE QS P AIR PRESSURE SWITCH 0. A. OUTSIDE AIR Q THERMOSTAT QS AS DISCHARGE AIR SENSOR S.A. SUPPLY AIR NOTE: ALL EXISTING SENSORS, CONTROLS, WIRING, ETC. SHALL BE REMOVED R. A. RETURN AIR UNLESS SPECIFICALLY INDICATED OTHERWISE. RTU ROOFTOP UNIT (AIR CONDITIONING) SENSOR LEGEND ABBREVIATIONS TRUE PLAIN NORTH NORTH � EQUIPMENT ROOM �� 2 � �� NEW DUCTWORK -SIZE AS INDICATED T ;; I I I ; FIRST DIMENSION IS FACE OF DUCT EXTG, PRODUCE PREP. RIM. II I i SHOWN ON PLAN, �� I I EXISTING DUCTWORK RE -USED IN PLACE. �ry �I II I I I C i 715 C ! 715 4�1------ I I n 715 I I 715 --------- I ---- I It I I �_--- 140_-_-1 ' I _ 140 _�® I I DUCT OGEE (UP IN DIRECTION INDICATED) II ELECTRIC DUCT HEATER EXISTING STORAGE FREEZER TING PRODUCE COOLEREDHEXIS40�%� I ii IoI I I I_NI_ _ __ _ ____ _ _ �__ _�__ .__ _�_____ _ ___ _____ - ___�_. __ __ ____ __ ._____ _� _ _r__�_ MOTOR OPERATED DAMPER I " 2670 - I I I I MOD (NEW OR EXISTING AS INDICATED) I ------------- JJ I I ISI 221 _ /1 I I --- ---1-� __ I o I I------------ I/ I I I F267�0VOLUME DAMPER I - -IL J I I, I I I I;-- i ---- I I EXISTING MEAT COOLER 715 �'¢_-- C I I ( I ® NEW SUPPLY DIFFUSER II MI:f4-0 I I 2670 12x12 UP TO EF -6 I IL- II LLi I I I I C ®R RE-USED/RELOCATED EXISTING DIFFUSER I I --r-----------.571 I I C C I I l 3- 220 - - - - - - - I/ I I I I 2670 I 715 11 715 (; D I� I _ I I C N I _ _ _ _ 715 ; ; NEW RETURN GRILLE 800 I " II �� I I 14 I Z---_-_140-_-_-_-_ _ 140 - � - - - - - - - - - - ® ® - _ ® RELOCATE EXISTING RELOCATE EXISTING FLY FAN _ --- -- - -, _ 1 I it 220_ - - _ _ - - - I / I I - - - 715 I I SENSOR - MOUNT TO CEILINGCONNECT TO EXISTING r I! ISI I I I I /"I I - `tel M _ SII ---'"� •---- [� _„� �� jt ' III I ®5I -----I II Q ISI IIII Ii Ii 7A15 i i 4 UNDERCUT DOOR5236 7 FF-3 II 140 NFF-1 __ - - - - ------- -- - - EXISTING EUH TO REMAIN-/y-----ri5 C-4 -T- 21 -----i 2670 ( 2 14x14 ;; ; ; I 10x10 UP TO I ri-I ------------ ,8x,8 ---- "' - ------ SYMBOL LEGEND ,--- EF -3 TO REMAIN I II ' _,- , I I ''I I I I I EDH-1 Z I I I I " ' 220 - I / I I I L2��70 _ _-_ ,3.7 1. M.C. SHALL FIELD VERIFY ALL EXISTING CONDITIONS AT THE JOB SITE PRIOR TO ---r--------- - - -- ---I-------L/ J I I I _I EXISTING RECEIVING Ronrj �_ —lr--=-I�-�--==--I -,- .-._ _.____ _ _ _ _._.._ _. __.__ __ __ _._._ . __ _ _ __ __ _ ____ -- -- I - - ---- -- --I-I - - -- -- l -r-{-- - -- I �- - BEGINNING WORK. NOTIFY Kash N' Karry OF ANY DISCREPANCIES, ��� I II II1!t1I i� � MT. FzzH. E�II � II „iiii r, 715 IIIS�I L(,�p 2. DUCT SYSTEMS SHALL BE CONSTRUCTED IN ACCORDANCE WITH LATEST SMACNA FAT I 4_4_______ X(O. ® I[2:C670 STANDARDS WITH LIMITATIONS AS NOTED BELOW OR IN SPECIFICATIONS. ALL I ® _ _ ® DUCTWORK SHALL BE CONSTRUCTED TOA 1 PRESSURE CLASS, C-14 1 --___ -r� I I X 1 1o 220 1 I �7O 7 7 _ _________ l_-4 A 3, ALL DUCTWORK WITH A WIDTH DIMENSION OF 46 OR LARGER S HALL BE C1B0 ELECTRICAL I - - - - - - - - - - - - - 40- 4i0---- _X4_I® SUPPORTED WITH TRAPEZE TYPE HANGERS AS INDICATED PER DETAILS O N Rn�n- I _ _ _ _ 22� 715 SHEET M-3, SUPPORTS SHALL BE ATTACHED TO DUCTWORK PRIOR TO _ _ _ _ _ _ _ / I 800 I I I I L_J i i J I I �, I I EXISTING VESTIBULE I I I I I I _ 3.1 APPLICATION OF EXTERNAL INSULATION. INSULATION SHALL BE APPLIED TO �� 715 --------------- '��— COMPLETELY COVER DUCTWORK AND SUPPORTS. I I i I I M2O L0 I I - --�� --- - ------ ---- -._ ___ .._ L____ _ ___ __. _ _�____. _- .—_- -._-_ .- ----- _ ._—•- - --_l__ I ___- _ .A—_ _. _ _ �„�- __ _ -- -- -- f --,—t --- � 4, DUCTS CONNECTING TO NEW AND/OR RELOCATED DIFFUSERS SHALL BE INLET FF -4 I I I I I I II i i I I SIZE OF DIFFUSER. PROVIDE VOLUME DAMPER FOR BRANCH TAKEOFF AS FF -5 iXi I I 44✓= — - I 11 7C5 I I I I I I INDICATED ON PLAN. SEE DETAILS ON SHEET M-3, I i — ,I00 N z I�I I I I I I I I M15 5, ALL LONGITUDINAL SEAMS AND NON-GASKETED TRANSVERSE JOINTS SHALL BE X I I -�I I I I I EXTERNALLY SEALED WITH HIGH PRESSURE DUCT SEALER BY UNITED McGILL OR +I C i8x10 E ' 81 �Y I I I _ _ _ _ _ - - - - - a M EQUAL,. SEALER SHALL . BE APPLIED BY M.C. AND APPROVED BY Kash N Karry I I _ I li 715 00 - -r----- __17 -7-----Y,r= „ ( L I X j- - 500 I I REPRESENTATIVE BEFORE DUCT INSULATION IS INSTALLED. I I - II I---------� I N I SII - xE f� I II 2020 150 I II ® 141 I I /� loxton 6, ALL NEW DUCT SIZES SHOWN ARE "INSIDE -CLEAR" DIMENSIONS. ALL NEW I SoCo I I r— u�P it C C I I /' RTU -DB TO ®ExsR EF -4 500 I DUCTWORK SHALL HAVE 2", 3/4 PCF, EXTERNALLY WRAPPED INSULATION WITH I i I �_ - I, 715 715 I I , REMAIN I c ��E �___ - __.� VAPOR BARRIER SEE SPECIFICATIONS . ROUTE ALL NEW DUCTWORK AS TIGHT _ �_._ _ m �._ _. __. ._I ._.___..._ _.__._.__. __ .__.___ _ .__ ____ __-_ -_ .___ :._,, . _ _._ _ _ __ _ _ _ .._ -too - - _ _- ( ) 1 20 0�� - EXISTING DAIRY CCCLER II I I I I �;--------= � _ - __ _ _� - - `�� TO ROOF JOISTS AS PRACTICAL, COORDINATE ROUTING TO AVOID CONFLICTS I I ® I I r �+ r 7L � -) WITH OTHER TRADES. _ AHU-1 I+ �I I I -_I C ---- II EDH-1 \f'I I^I I Ic i �'r 1-- -I I II ,, i I I � i � H I I I ;I I/ I 11/1 IXI 1 F �I I ! i I I I --- I-�1------------=-` -�T I I ; II /L_J-� J EXISTING D/B + 7. FLEXIBLE DUCT MAY BE USED AT END OF RUNOUTS IN LENGTHS NOT I--- i II � _--------- (------ --------------I r/ II COOLER 200i- - T T , +, C 121- I I EXCEEDING 4'-0". INSTALL PER SMACNA STANDARDS (SEE SPECIFICATIONS). I I I / I I r l I( i i I I 72x28 I I 44x28 I I I 36x28 I_ ' PC TRAININL' RM 2250 �\ ,�-- /18xT8- I 1 II I I -- I . I _ _ 8. PROVIDE 90' METAL 24 GA. MINIMUM DUCT ELBOW WITH 4 PIECE GORE AT i I I---j=�'------(-- � � I � I I �� I �*I u C KH -1 TO REMAIN � � '� _ ®� ALL NEW CEILING DIFFUSER/GRI LLE -TO -FLEX DUCT CONNECTIONS, I �- - - - - J iI I II— - - -I-I — - -I-I - -I-I— .-1-1- - 1--1-- - •I -I ----- I -I- - -� -�- C I -N E- Soo- - ��_--_--�_s1 800 OA DUCT UP TO I--r�-- I I I I I I I I I I I I I I I I I 600 I I®� 32x18 GOOSENECK 10x10 UP TO I u e e e ISI i� 121 I I 100 ® _I ON ROOF TO REMAIN II C I I ISI ISI ISI ISI ISI ISI I �� C_ 9, M.C. SHALL VERIFY SIZE OF EXISTING DUCTWORK SCHEDULED TO REMAIN. INTERMEWNG ROOM I I ( EF -2 TC I! ® I I I' I H I' I 1= I I�I N I -I I ,I ; ; EQUIPMENT OPENINGS AS REQUIRED FOR PROPER CONNECTION OF NEW TO REMAIN I, 715 I I I I I I I I I I i i i 120 r T� R l i EXISTING. w H I ® I ® ® I I CJI I + ISI I I I I I I I I � ; I I I -- T�_ L� J I I SEXISTING D B I C I I I I ; II I I I 10, M.C. SHALL INSPECT AND REPAIR DUCTWORK AS REQUIRED TO PROVIDE A TIGHT TORAGE g OM I ``I C I I I I I C 1 1 C \\ I „ DELI/BAKERY AREA I I C \' C I I = 6� I I I� I I I I I 715 I I 715 I I 715 \\ LI I I I I I KH -1 I I AIR DISTRIBUTION SYSTEM, M.C. SHALL CAP AND INSULATE ALL OPEN DUCT 250 I , ,l 600 L_ I I TERMINATIONS AND OTHER OPENINGS IN EXISTING DUCTWORK DIRECTLY ____II_ __ I I I I I I , n I�I ,, -------- - I --- -I I II x DEMOLITION. LL SUPPLY D E URN I II IL II 20x�8_-_it_ __"24x24I I I + + RESULTING FROM OR INCIDENTAL TOA AN R T7EDH- 3� --ii -Igl I I I I I I I; 121 OUTLETS SHALL BE BALANCED TO THE AIR FLOW QUANTITIES SHOWN ON MEN'S RM., II I I I I -------® SoowGMEN's RM. I C DRAWINGS. (0 11IISI I I+ I II I Fj­ �I C® C® C C C® C® u-- II I I I I ;; 600 11. M.C. SHALL PROVIDE PREFABRICATED ROOF CURBS FOR INSTALLATION BY G.C. I ATG. ICE UZFAIA FREEZER 715 715 715 715 715 715 --1 �^ G.C. SHALL PROVIDE AND INSTALL ALL FIELD FABRICATED MECHANICAL CURBS EF -D TO REMAIN l _ I I _ -� II j ,! Exlsnlvc D/e ; ; AND PROVIDE FLASH INS TO ROOF SURFACE AS REQUIRED FOR WATERTIGHT C -- H �+ II FREEZER I I INSTALLATION AT ALL NEW OR MODIFIED MECHANICAL ROOF PENETRATIONS. G.C. EXISTING CORRIDOR #2 +I 6x6 U TO ROOF „ I I 100 ! ! CAP�T0 REMAIN II SHALL REPAIR ALL ROOF AND/OR WALL OPENINGS RESULTING FROM ' I I MECHANICAL PENETRATIONS REMOVED DURING DEMOLITION. EXTO. SECURITY ROOM L ------- r- I i 12, M.C. SHALL COORDINATE ALL WORK WITH OTHER TRADES TO AVOID CONFLICTS. I I —-- (� 13. COORDINATE ALL DIFFUSER AND GRILLE LOCATIONS WITH CEILING GRID AS I i i I SHOWN ON ARCHITECTURAL DRAWINGS. i — 10x10 FROM OVEN ! UP TO EF -5 ON ROOF 14, M.C. TO COORDINATE DUCTWORK SIZES WITH CLEARANCES ABOVE CEILING. M.C. SEE SHEET M-3 FOR TO NOTIFY PROPER Kash N' Karry REPRESENTATIVE OF ANY CONFLICTS. F 5 rSCHEDULE AND DETAILJ F3 A. p . 4)(E)��,,,/ ` _ � ✓ 15. REFER TO SPECIFICATIONS, DIVISION 15 SECTIONS FOR ADDITIONAL MECHANICAL REQUIREMENTS, MECHANICAL - FLOOR PLAN 3/32`=1'-O` SCALE 1 RENOVATION NOTES ARCHITICTUR[ [US I N T E R N A T I O N A L 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813,281.9292 E—Mail api@architectureplus.com ® BOWERS C ONS ULTING, PA C ONS ULTING ENGINEERS 1425 JAKE ALEXANDER BLVD. SOUTH - SUITE B J. PO BOX 1711 (28145) SALISBURY, NC 28146 PHONE: (704)630-0075 FAX:(704)630-0051 EMAIL:bowers®vnet.net CERTIFICATE, OF AUTHORIZATION #8458 F Dash n' OAS DATED ARCHITECTUREPLUS INTERNATIONAL, INC. Zh 7/19/01 FLOOR PLAN REVISION Zj, 9/04/01 FOOD LION COMMENTS .............................................. REVISION LOG STATE REGISTRATIONS FL #AA001935 NC #8581 10 TO THE 'BEST OF THE'KNOwtEDGE OF THE ARCHITECTS AND ENGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE MINIMUM BUILDING CODES AND THE APPUCABLE MINIMUM FIRE SAFETY STANIDARDS. K9.sh1,,N.'..1K1a1lr,r,y„No.., 1.118190 SANFORDt,,,F�,,,,,,,,,,,,,,,,,,,,,,, PROJECT NAME M.ECH,A,N,I,CAL. ................. FFLOO,R,,, PL.,A,N„:,,11,,,,,,,,,,,,,,,,,, SHEET NAME PROJECT NUMBER: 9949.00 DRAWN BY: MDB CHECKED BY: MDB SCALE: AS NOTED ISSUE DATE; 9/27/01 ISSUE FOR: PERMIT SHEET NUMBER i AIR DISTRIBUTION SCHEDULE TAG MFR MODEL LISTED SIZE a TYPE FINISH INTEGRAL DAMPER REMARKS A KRUEGER SH4FR23—PC 15x15 24x24 ' SUPPLY OW NO SUPPLY DIFFUSER B KRUEGER EGC5 12x12 AIR DISTRIBUTION SCHEDULE TAG MFR MODEL LISTED SIZE FACE TYPE FINISH INTEGRAL DAMPER REMARKS A KRUEGER SH4FR23—PC 15x15 24x24 ' SUPPLY OW NO SUPPLY DIFFUSER B KRUEGER EGC5 12x12 -- RET/EXH AL YES EGGCRATE, ALUMINUM C EXISTING -- -- -- RET/SUP -- -- CLEAN AND RE—USE EXISTING PER SHEETS M -1/M-2 D KRUEGER EGC5 14x14 -- RET/EXH AL YES EGGCRATE, ALUMINUM E KRUEGER 585H 18x10 -- SUPPLY OW YES SUPPLY GRILLE F KRUEGER SH4—PC 6x6 2424 SUPPLY OW NO SUPPLY DIFFUSER FAN SCHEDULE MARK MFR MODEL LOCATION SERVES TYPE CFM EXT. S.P. IN WG NOM RPM DRIVE ELEC. DATA DB RTU HP W VOLTS PH HZ REMARKS EF -4 COOK GN -720 CEILING OFFICE STORAGE CABINET FAN 500 0.500 1300 DIRECT -- 143 120 1 60 SEE NOTE #1 EF -5 COOK VCRHP-150 DELI RACK OVEN CENTRIFUGAL ROOF 750 0.750 1750 BELT 0.25 -- 120 1 60 SEE NOTES #1 AND #2 EF -6 COOK ACED -120 ROOF SEAFOOD PREP CENTRIFUGAL ROOF 800 0.375 1041 DIRECT 1/6 -- 120 1 60 SEE NOTE #1 FF -1 EXISTING -- WALL GROCERY STORAGE -- -- -- -- -- -- -- -- -- -- NOTE 3 FF -2 EXISTING -- WALL GROCERY STORAGE -- -- -- -- -- -- -- 120 1 60 NOTE 3 FF -3 LEADING EDGE E4800-1175SM WALL GROCERY STORAGE -- 3880 -- -- -- 0.75 -- 120 1 60 MAX AMPS=7.8 FF -4 LEADING EDGE E9600-2300SM WALL GROCERY STORAGE -- 8400 -- -- -- (2) 1.0 -- 208 1 60 MAX AMPS=6.4 FF -5 LEADING EDGE I E9600-2300SM WALL GROCERY STORAGE -- 8400 -- -- -- (2) 1.0 -- 1 208 1 60 MAX AMPS=6.4 NOTES: 1. PROVIDE ROOF CURB, DISCONNECT SWITCH AND BIRDSCREEN. 2. FAN SHALL HAVE AN UL NUMBER OF 762. 3. MC TO VERIFY OPERATION OF FLY FAN WITH KnK CONSTRUCTION REPRESENTATIVE, REPLACE IF REQUIRED. AIR BALANCE SCHEDULE MARK MAKE—UP AIR CFM EXHAUST AIR CFM REMARKS AHU-1 3,600 -- EXISTING AHU RTU—DB 750 --- DB RTU EF -1 -- 500 RESTROOMS HOOD EXH. 3,000 4,000 DELI/BAKERY HOOD EF -3 -- 450 JANITOR EXHAUST EF -6 -- 800 SEAFOOD PREP EF -DB -- 100 D/B CLOSET EXHAUST FAN EF -4 -- 500 OFFICE/STORAGE EF -5 -- 750 OVEN EXHAUST ,FAN TOTAL 7,350 7,100 _ TOTAL DIFF 7,350 - 7,100 = +250 CFM `12x8 ACCESS DOOR FOR CLEANOUT EXHAUST DUCT FOR BAXTER OVEN SHALL BE 16 GAUGE STEEL. ALL JOINTS AND SEAMS SHALL BE LIQUID TIGHT CONTINUOUS EXTERNALLY WELDED CONSTRUCTION. 10x10 HOOD VENT 12x8 ACCESS DOOR FOR CLEANOUT STEAM HOOD BAXTER OVEN FLOOR FRONT ELEVATION RACK OVEN ELEVATION SIDE VIEW RACK OVEN FLUE SECTION ROOF 7' BEAM CLAMP W/ RETAINING BAR JOISTS-"\ � CLIP AND LOCK NUT NUT &WASHER DUCT INSULATION SEE SPECS. 3/8" ALL—THREAD NUT BOTH&SIDESHER GALV. ROD MIN. \___UNISTRUT CHANNEL NOTE: DUCT SHALL BE INSTALLED AND HANGERS SPACED AS RECOMMENDED BY MANUFACTURER, NOT TO EXCEED 8'-0" SPACING. TYPICAL RECTANGULAR DUCT HANGER FAN MOTOR FAN WHEEL ELEC. CONDUIT— BIRD ` SCREE IF ROOF CURB BY G. C. S H EETM ETAL------- ...... CURB CAP BURGLAR BARS BY COORDINATE WITH MECH. CONTR. — 10x10 HOOD VENT UP EXHAUST FAN ON R( 12x8 ACICESS C FOR CLEAT RACK OVEN FLUE DETAIL NO SCALE NO SCALE ALUMINUM HOUSING / ROOF STRUCTURAL STEEL SUPPORT BACKDRAFT DAMPER —EXH. DUCT TYPICAL ROOF FAN DETAIL Z I"lI I n/ IAJr- n PLAN VIEW RACK OVEN FLUE DETAIL NO SCALE =45' =1 /4W, 41 RECTANGULAR RETURN I=45' =1/4W, 4"MIN. RECTANGULAR SUPPLY TYPICAL DUCT BRANCH TAKE -OFFS NO SCALE ;AP 5 ROOF CAP DETAIL NO SCALE ROOF FLEX DUCT 4'-0" MAX 90° METAL DUCT ELBOW _\ WITH EXTERNAL WRAPPED INSULATION. MINIMUM 24 GAUGE, 4 PIECE GORE ~DUCT TAKE—OFF EXTERNALLY WRAP ENTIRE ASSEMBLY WITH INSULATION "T" BAR CEILING �,DIFFUSER CONNECTION DETAIL AIIAGH RUU IU KUUF 5I PROVIDE SUPLEMENTAL S_ 1/2" THREADE1 (TYP. FOR 4) FLY FA ROLL—UF NO SCALE EXTERIOR WALL FLOOR I L! NOTES: 1. M.C. MAY USE FIELD FABRICATED ANGLE SUPPORT BRACKETS IN PLACE OF THREADED RODS. 2. FF -2 SHALL BE HUNG FROM EXTERIOR WALL. 7 FLY FAN DETAI L NO SCALE ARCHITICTURI [US INTERN ATI 0 NAL 2709 Rocky Point Drive, Suite 201 Tampa, Florida 33607 Tel 813.281.9299 Fax 813.281.9292 E—Mail api@architectureplus.com n ,,y BOWERS CONSULTING, PA C ONS ULTING ENGINEERS 1425 JAKE ALEXANDER BLVD. SOUTH — SUITE 8 1 PO BOX 1711 (28145) SALISBURY, NC 28146 PHONE: (704)630-007 FAX:(704)630-0051 EMAIL:bowers®vnet.net CERTIFICATE OF AUTHORIZATION #8458 r ih OAS DATED ARCHITECTUIREPLUS INTERNATIONAL, INC. 01 7/19/01 FLOOR PLAN REVISION 9/4/01 FOOD LION COMMENTS ..................... ............................... ..................................................... REVISION LOG STATE REGISTRATIONS FL.... .. A001 ................. N C „#8581 I As N TO THE BEST OF THE KNOWLEDGE (OF THE ARCHITECTS AND EXGINEERS, SAID PLANS AND SPECIFICATIONS COMPLY WITH THE ,APPUCABLE MINIMUM BUILDING CODES AND THE APPLICABLE. MINIMUM FIRE SAFETY (STANDARDS. Ka,sh,,,N,',,,K,la,rr,y,.N,o.,, 1,8,90 SAN F;ORD?... F�....................... PROJECT NAME M,ECH,A,N,(,CAL SCH ED,U L,ES,, A I. D ETA,I,LS SHEET NAME .... , ...,. . PROJECT NUMBER: 9949.00 DRAWN BY: MDB CHECKED BY: MDB SCALE AS NOTED ............................ ISI I.SU1 1.E 1 1.DATE; 9/2/01 ISSUE FOR: PERMIT M�3 SHEET NUMBER