Loading...
2921 Orlando Dr #150 - BC05-000781 (INDUSTRIAL COMMERCIAL STRUCTURE) (A)CERTIFCATE OF OCCUPANCY REQUEST FOR FINAL INSPECTION ****INTERIOR COMMERCIAL REMODEL**** DATE: PERMIT #:` ADDRESS: PHONE #: 06/17/05 05-781 2921 Orlando Dr #150 Industrial Commercial Structures The building division has prepared a Certificate of occupancy for the above location and is requesting final inspection by your department. After your inspection, please sign off and date the C. o. or submit addendum if it has been denied or approved with conditions. Your prompt attention will be appreciated. ngineerin �� ��fl, Tire ❑Public Works ming ❑Utilities Licensing CONDITIONS: (TO BE COMPLETED ONLY IF APPROVAL IS CONDITIONAL) 7 z PHOTOCELL "PC -1" TORK CAT. #2101(120V) MOUNT ON ROOF FACING NORTH H.O.A. SELECTOR SWITCH "HOA -1" MOUNT IN NEMA 1 ENCLOSURE LIGHTING CONTACTOR 10-1" MOUNT IN NEMA 1 ENCLOSURE TIME CLOCK TORK CAT. #W220L (120V) 120V CONTROL CIRCUIT Ll -29 TO EXISTING PANEL "L1" TO EXTERIOR LIGHTS CIRCUIT NO. 29 NOTE: 1. LIGHTING CONTACTOR SHALL BE A MECHANICALLY HELD TYPE, RATED AT 30 AMPS WITH COIL CLEARING CONTACTS. PROVIDE CONTACTS AS REQUIRED. TYPICAL PHOPOCELL 00"N / TIME . 1"K OFF CONTROL DUAL NOT TO SCALE SOLID CONCRETE OR UL RATED BLOCK WALL 3" MINERAL WOOL EACH SIDE 1" MIN. 3M FIREDAM 150 CAULK N I 1/4" MIN. - 1 3/8" MAX. ANNULAR SPACE COVER LIFT HOLE 3" HIGH LETTERS CAST IN COVER COVER LIFT HOLE #4 AWG TINNED - COPPER GROUNDING CONDUCTOR, PROVIDE 36" SLACK MECHANICAL CONNECTOR GROUND TEST WELL -� '.0,111111w aasp, #2/0 AWG TINNED --- COPPER COPPER GROUNDING CONDUCTOR TO OTHER GROUND RODS BROOKS PRODUCTS NO. 1100 COVER FINISHED GRADE GRAVEL GROUND ROD 1100 COVER 8-0 J, o 2'r o "SNAP LOCK" TABS GROUND TEST WELL DETAL NOT TO SCALE I BODY 29"0' PIPE SLOT (TYPICAL OF 2) 13'1"0 NOTES BOBES ASSOCIATES CONSULTING ENGINEERS ELECTRICALGENERAL APPLIES TO ALL DRAWINGS (SOME SYMBOLS MAY NOT BE USED ON THIS PROJECT.) 1. BRANCH WIRING IS NOT SHOWN GRAPHICALLY ON DRAWING AND IS B D T INDICATED BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND FLORIDA STATE P.E. NUMBER: 5131 EQUIPMENT, PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT R 1/4" MIN. - 1 3/8" MAX. ANNULAR SPACE COVER LIFT HOLE 3" HIGH LETTERS CAST IN COVER COVER LIFT HOLE #4 AWG TINNED - COPPER GROUNDING CONDUCTOR, PROVIDE 36" SLACK MECHANICAL CONNECTOR GROUND TEST WELL -� '.0,111111w aasp, #2/0 AWG TINNED --- COPPER COPPER GROUNDING CONDUCTOR TO OTHER GROUND RODS BROOKS PRODUCTS NO. 1100 COVER FINISHED GRADE GRAVEL GROUND ROD 1100 COVER 8-0 J, o 2'r o "SNAP LOCK" TABS GROUND TEST WELL DETAL NOT TO SCALE I BODY 29"0' PIPE SLOT (TYPICAL OF 2) 13'1"0 © Copyright 2004 ACi, Inc. C 11 -SA HUMAN SERVICES ASSOCIATES, INC. C� C�� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida ACi ASSOCIt1TED CONSULTING IN I'ERNA'I'.I0NAL ® ■ • DE�TLOPNIENT.l UkNAGENIENT =ARCHITECTURE FL AA0002940 955 Ni. PENNSYLVANIA AVE. WINTER PARD., FLORIDA 32789 USA PHONE: (407) 740-8405 FAY: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material Information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. 701-31 NOTES BOBES ASSOCIATES CONSULTING ENGINEERS ELECTRICALGENERAL APPLIES TO ALL DRAWINGS (SOME SYMBOLS MAY NOT BE USED ON THIS PROJECT.) 1. BRANCH WIRING IS NOT SHOWN GRAPHICALLY ON DRAWING AND IS B D T INDICATED BY CIRCUIT NUMBERS BESIDE FIXTURES, DEVICES AND FLORIDA STATE P.E. NUMBER: 5131 EQUIPMENT, PROVIDE COMPLETE WIRING SYSTEM WHETHER OR NOT ® RECESSED FLUORESCENT FIXTURE, UPPER CASE INDICATED GRAPHICALLY. PHASE BALANCE ALL PANELBOARDS IN THE FIELD. LETTER INDICATES FIXTURE TYPE 0 SURFACE OR PENDANT MOUNTED FLUORESCENT FIXTURE 2. LIGHTING FIXTURES ARE SHOWN FOR QUANTITY AND CIRCUITING ONLY. FOR EXACT LOCATION OF LIGHTING FIXTURES, REFER TO ARCHITECTURAL WALL MOUNTED FLUORESCENT FIXTURE REFLECTED CEILING PLANS. COORDINATE WORK WITH CEILING CONTRACTOR. PROVIDE PROPER FIXTURE FRAMES FOR TYPE OF CEILING INDICATED. INCANDESCENT, FLUORESCENT OR HID DOWNL IGHT. 3. FOR EXACT ARCHITECTURAL LAYOUT AND DIMENSIONS, COORDINATE WITH OK a UPPER CASE LETTER INDICATES FIXTURE TYPE, SUBSCRIPT ARCHITECTURAL DRAWINGS. ELECTRICAL DRAWINGS ARE FOR REFERENCE ONLY. LETTER INDICATES SWITCH CONTROL. 4. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE AMERICANS WITH )PH WALL MOUNTED EMERGENCY LIGHT, BATTERY UNIT DISABILITIES ACT (ADA) AND 2002 NATIONAL ELECTRICAL CODE (NEC), (ZH WALL MOUNTED INCANDESCENT, FLUORESCENT OR HID FIXTURE 5. COORDINATE ALL WORK DONE UNDER THIS DIVISION WITH WORK TO BE PERFORMED UNDER DIVISION 15.;® CEILING MOUNTED EXIT LIGHT. ARROW INDICATES DIRECTIONAL ARROW ON FIXTURE, SHADED AREA INDICATES FACE OF FIXTURE. 6. COORDINATE WITH OTHER TRADES FOR EXACT LOCATIONS OF ALL MOTORS AND OTHER EQUIPMENT TO BE INSTALLED AND/OR WIRED UNDER THIS DIVISION CIA WALL OR END MOUNTED EXIT LIGHT BUT FURNISHED UNDER ANOTHER DIVISION OF THE SPECIFICATIONS. OA PHOTOCELL 7. ALL BRANCH CIRCUITS FOR 120 VOLT, 20 AMP CIRCUITS EXCEEDING EIGHTY FEET IN LENGTH SHALL BE #10 AWG ENTIRE CIRCUIT MINIMUM. $0 SINGLE POLE SWITCH, SUBSCRIPT LETTER INDICATES FIXTURE CONTROLLED. (3 = 3 WAY, 4 = 4 WAY, K = KEY OPERATED) MOUNTED 48" AFF 8. PACK ALL SLEEVES FOR CONDUITS PASSING THROUGH FIRE RATED WALLS AND FLOOR SLABS WITH FIRE RESISTANT MATERIALS. ALL PENETRATIONS ®-` SPECIAL RECEPTACLE SHALL BE UL RATED. 9 DEDICATED RECEPTACLE 9. ALL EMPTY CONDUITS (EC) SHALL BE PROVIDED WITH NYLON PULL WIRES. 20A, 2 POLE, 125V GROUNDED DUPLEX RECEPTACLE. 10. TYPE AC CABLE AND ELECTRICAL NON-METALLIC TUBING SHALL NOT BE PERMITTED. G 18" -AFF UNLESS OTHERWISE NOTED. G = GROUND FAULT INTERRUPTER 11, COORDINATE THE REQUIRED SIZE OF ALL CIRCUIT BREAKERS FEEDING EQUIPMENT 20A, 2 POLE, 125V GROUNDED DUPLEX RECEPTACLE. (I.E. MOTORS, HVAC, KITCHEN EQUIPMENT, SPECIAL PURPOSE OUTLETS, ELEVATORS, MOUNTED ABOVE COUNTERTOP UNLESS OTHERWISE NOTED. OWNER FURNISHED EQUIPMENT, ETC,) WITH APPROVED EQUIPMENT SHOP DRAWINGS TELEPHONE WALL OUTLET- 18" AFF UNLESS OTHERWISE NOTED. AND OWNER REPRESENTATIVES PRIOR TO ORDERING PANELBOARDS. BREAKERS P ® = SHALL BE SIZED PER THE NEC, THE EQUIPMENT NAME PLATE AND MANUFACTURER'S P PAY PHONE OUTLET MOUNTED 48" AFF. PROVIDE 1" EC TO TELEPHONE RECOMMENDATIONS. TERMINAL BOARD (TTB). ( ) 12. THE POWER COMPANY SHALL BE CONTACTED WITHIN 10 DAYS OF THE AWARD OF d TELEPHONE AND DATA DUPLEX OUTLET, 18" AFF UNLESS OTHERWISE NOTED. THE CONTRACT BY THE CONTRACTOR TO VERIFY THE ACTUAL AVAILABLE SHORT CIRCUIT FAULT CURRENT (SGC) AT THE TRANSFORMER SECONDARY BUSHINGS. THE H TELEVISION OUTLET WITH 1" EC TO TTB. 18" AFF UNLESS OTHERWISE NOTED. CONTRACTOR SHALL PROVIDE ELECTRICAL DISTRIBUTION AND UTILIZATION EQUIPMENT AND PANELBOARDS WHICH HAVE AIC/WITHSTAND RATINGS GREATER THAN THE Q CEILING MOUNTED JUNCTION BOX AVAILABLE SCC. 13. ALL CONDUITS IN OR UNDER SLAB OR UNDERGROUND SHALL BE PVC QJ I WALL MOUNTED JUNCTION BOX SCHEDULE 40. 14. ALL CONDUITS ABOVE SLAB, WHETHER EXPOSED OR CONCEALED, SHALL BE EMT, © CONNECTION TO EQUIPMENT IMC, OR RIGID GALVANIZED STEEL. PUSHBUTTON. 15. FLEXIBLE METAL RACEWAYS SHALL NOT EXCEED 6' IN LENGTH, sM MOTOR HORSEPOWER RATED TOGGLE SWITCH BY DIVISION 15 16. "LIQUID -TIGHT" TYPE FLEXIBLE WEATHERPROOF RACEWAYS SHALL HAVE A 11, METALLIC INTERIOR AND NOT EXCEED 6' IN LENGTH. NONFUSED DISCONNECT SWITCH. NUMBERS INDICATE SWITCH SIZE. 60A/2P/NF 17. ALL BOXES, PLASTER RINGS, EXTENSION RINGS, AND BOX COVERS SHALL Ey FUSED DISCONNECT SWITCH. FUSES SIZED AS SHOWN ON DRAWINGS. BE METAL. / V' MOTOR 18. ALL CONDUITS SHALL BE PARALLEL AND PERPENDICULAR TO STRUCTURAL MEMBERS. PANELBOARD 19. ALL BENDS SHALL BE MADE IN CONDUIT USING PROPER EQUIPMENT AND MEET NATIONAL ELECTRICAL CODE (NEC) REQUIREMENTS. FACP® FIRE ALARM/SECURITY CONTROL PANEL 20. ALL WIRE, INCLUDING BUT NOT LIMITED TO FEEDERS AND BRANCH CIRCUIT FAAP ® FIRE ALARM ANNUNCIATOR PANEL WIRING, SHALL BE COPPER - #12 AWG THWN MINIMUM. ALL CIRCUITS REQUIRING NEUTRALS SHALL BE FURNISHED WITH DEDICATED NEUTRAL CONDUCTORS. ❑I INTERCOM 21. ALL BREAKERS SHALL BE "FULL SIZE". NO TANDEM, PIGGY BACK, TWIN, OR SO CEILING SPEAKER HALF SIZE BREAKERS WILL BE ACCEPTED. BREAKER MUST BE APPROVED BEFORE INSTALLATION. r TELEPHONE TERMINAL BOARD (TTB) r 22. ALL DEVICES SHALL BE COMMERCIAL OR SPECIFICATION GRADE. F ' FIRE ALARM STROBE LIGHT, MOUNTED 80" AFF , o 23. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE FOR TEMPORARY POWER OF FIRE ALARM MANUAL PULL STATION, MOUNTED 48" AFF AND TEMPORARY LIGHTING DURING CONSTRUCTION. TEMPORARY POWER SHALL PROVIDE ADEQUATE POWER FOR NORMAL CONSTRUCTION USE. F FIRE ALARM SPEAKER WITH STROBE LIGHT, MOUNTED 80" AFF TEMPORARY LIGHTING SHALL PROVIDE ADEQUATE LIGHT SO THAT THE INDIVIDUAL ' TRADES WORK CAN BE COMPLETED, FS SPRINKLER FLOW SWITCH 24. ALL ELECTRICAL EQUIPMENT SHALL BE UL LISTED. TS SPRINKLER TAMPER SWITCH ', 25. A GREEN INSULATED COPPER GROUND CONDUCTOR SHALL BE INSTALLED LB KEY LOCK'.BOX , IN ALL RACEWAYS, SIZED ACCORDING TO NATIONAL ELECTRICAL CODE, 26. PROVIDE A COMPLETE LIGHTNING PROTECTION SYSTEM FOR THE BUILDING TO ® HF!T Di_'ECTOR COMPLY WITH THE REQUIREMENTS OF NFPA 70, NFPA 780, LPI STANDARDS 175, 176, AND 177. PROVIDE COMPONENTS WHICH ARE UL -LISTED AND MASTER DUCT SMOKE DETECTOR LABELED. COORDINATE ALL ROOF PENETRATIONS WITH ROOFING CONTRACTOR. ® S,YOKE DETECTOR 27. GROUNDING SYSTEM SHALL BE IN ACCORDANCE WITH NEC ARTICLE 250 AND APPLICABLE REQUIREMENTS OF IEEE- STANDARDS 142 AND 241.R❑ AHU'F.IRE ALARM SHUTDOWN RELAY 28. TEST RESISTANCE TO GROUND (EARTHING CONNECTION) WITH RESISTANCE DC SECURITY._SYSTEM DOOR CONTACT TESTER SUBSEQUENT TO FINAL INSTALLATION. WHERE TEST INDICATES RESISTANCE TO GROUND IS OVER 5 OHMS, TAKE APPROPRIATE ACTION AFF ABOVE FINISHED FLOOR TO REDUCE RESISTANCE TO 5 OHMS OR LESS BY DRIVING ADDITIONAL PROPERLY SPACED GROUND RODS AND TREATING SOIL IN PROXIMITY FF FINISHED FLOOR OF GROUND RODS WITH COMMON SALT, COPPER SULFATE OR MAGNESIUM AHU AIR .HANDLING UNIT SULFATE. RETEST TO DEMONSTRATE COMPLIANCE. EC EMPTY CONDUIT 29. THE CONTRACTOR SHALL FURNISH AND INSTALL A COMPLETE 24 VDC, CLOSED CIRCUIT, ELECTRICALLY SUPERVISED, ZONE ANNUNCIATED, VOICE EVACUATION FIRE EF EXHAUST FAN ALARM SYSTEM (SIMPLEX OR APPROVED EQUAL) AS SPECIFIED HEREIN AND EWC ELECTRIC WATER COOLER INDICATED ON DRAWINGS. THE SYSTEM SHALL INCLUDE BUT NOT BE LIMITED TO ALL CONTROL PANELS, POWER SUPPLIES, SIGNAL INITIATING DEVICES, AUDIBLE EWH ELECTRIC WATER HEATER AND VISUAL ALARM DEVICES, WIRE, FITTINGS AND ALL ACCESSORIES REQUIRED G GROUND FAULT INTERRUPTER TO PROVIDE A COMPLETE OPERATING VOICE EVACUATION SYSTEM. THE SYSTEM SHALT- MEET ALL REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. CU CONDENSING UNIT WP WEATHERPROOF (NEMA -3R) 30. DIVISION 16 CONTRACTOR SHALL SUPPLY AND WIRE ALL SMOKE DETECTORS IN NL NIGHT LIGHT THE SUPPLY AIR DUCTWORK OF ALL AIR HANDLING UNITS OF 2000 CFM AND ST SHUNT TRIP ABOVE TO SHUT DOWN THE FANS IN THE EVENT OF A FIRE. DUCT SMOKE DETECTORS SHALL BE PHOTOELECTRIC TYPE AND LOW VOLTAGE, DIVISION 15 CONTRACTOR SHALL INSTALL ALL SMOKE DETECTORS. © Copyright 2004 ACi, Inc. C 11 -SA HUMAN SERVICES ASSOCIATES, INC. C� C�� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida ACi ASSOCIt1TED CONSULTING IN I'ERNA'I'.I0NAL ® ■ • DE�TLOPNIENT.l UkNAGENIENT =ARCHITECTURE FL AA0002940 955 Ni. PENNSYLVANIA AVE. WINTER PARD., FLORIDA 32789 USA PHONE: (407) 740-8405 FAY: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material Information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. 701-31 BOBES ASSOCIATES CONSULTING ENGINEERS 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628.7024 C® a f' i T © Copyright 2004 ACi, Inc. C 11 -SA HUMAN SERVICES ASSOCIATES, INC. C� C�� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida ACi ASSOCIt1TED CONSULTING IN I'ERNA'I'.I0NAL ® ■ • DE�TLOPNIENT.l UkNAGENIENT =ARCHITECTURE FL AA0002940 955 Ni. PENNSYLVANIA AVE. WINTER PARD., FLORIDA 32789 USA PHONE: (407) 740-8405 FAY: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material Information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. 701-31 BOBES ASSOCIATES CONSULTING ENGINEERS 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628.7024 C® E-MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 a�Zq� o s F ssues and Revisions Issue/Revision By 5 VE / REVISION I WMC Date: November 30, 2004 Checked By: WMC Drawn By: TT Project No.: 0416 File Name: _2010416,4\vg Phase: PERMIT DOCUiKENT Sheet Name: GENERAL NOTES, SYMBOL LIST AND SCHEDULES SHEET NUMBER E- 0. 1 !-1 3. 0 Im V) L. LLJ X i 0 a- 1) X 4- N I 0 M L -- I t�i _ I I ,, i 1 1' 1 1- 21 I , {., I 1 � ; I_i 1 1 _ VIA CONTACTOR) _29 - -- t ---- -------- �_ - - -- --- - _ -., _ . _� ..� ,:,,mss _ _,,,. - - , - - -i T i i 7 - 1 _ ' - - - - , 4 I T 1 . .I . , #r air 3 r --�,• i ; A I�I�; €. : » �, 1 S H 1 �P , L1- 21 _ I LL, 21, I - - I 1€r.2t I 3 # , X 4- > U I i .>= i v - = j J j' IYFF( , ' =r,_- _._i _ £ __ :i L_.� i€ 1 Y I A 1 - -- �a -- , I = ; I , -- - , r € - '� I _, . # , _- L1-23 ;' L1-23 1 I _' , 1 i __ -- I i __ I �1 Baa,,...' - _ _, _ ' _ _ I ,I I i �I L1 '23 = :;> ;: _ :. -- I j = B B I_ -I T Ll 23 j -_--- -—„,�..,_,.,,,�---tee.-�.,,,.,,.,. �,,.«,,,,�...,,.,,A-- __ $ �,,.,.,..<>- - __ _ - F - _ 3 - _ _ :-E _ -�- _ ,€ # , IX IP d b9= ; X_ I °G f G G EMAL1-16 G G EM G I L1 �� Ia ' L1-16 I � 1 0 L1-18 0 IIs _L1 23=;=° L1-14 I L_1=-t6p L1 -16p L1 -16p L1 -16p L1 -18r L1 -18r € > II 1 Lt E23 € ,1 -EM I ; G �_-_,:-__._. I 3 - 3 3 1 ' I # = `:•LJi .f f 1 , '• 3,= F ,ISI ��1� ,,R Gr�� >j£ 1- 8r� 3 _ � G i# E B 3 - 1 S S I -'� G : 3 _ _ 7' '': I _ _ -_, - _F' r,, _ - I s 1 I � ' --- _ (( _ I G i Q- - =T i4i Ia3 � 3 € - __' , I i 3i 11 1 1, ,' e.; ,z- r.-7; -_I=1 i:18r # I�f€sf saT ,O ` �I ---- 1 I I} -16p II !; L1 -18r _' _ W Ll� 18r II I I LI -16p I 1=PEN yS 1 s �7it 8- _ B L 1 G 1. I a f It �I I I I I L1 - :3 ; a: ]_ ;;� !;i �_ ` . F: ' _ 1 , €t i + II _ - - r -71 "P I' NIL G I L1 1 0; I 1_ - ` I ' 3 1 ;� 1 a , 1 'I 11 ;; I l8r _ 11 = 11 I! G ,�, I L1,=16 ' i j L1 -18r3 j L1-fi8r ,; I I C, = P-� , 1 L1 -18r ,3 € g - i I -' '- I I L1 -16p 1_ ,= I . MD. I 3 1.. 1 1 I� i_- - -- I -- - - -- - - II T « , , EMI - _ -__ _ - _-- - _ _ _ #I - _ - - - - _- - - - - __ - '� _�� -T_;- � --_- ; r --Ii , -s- - ------------------------ ----=---------_------ ;£ 11 -J 01-23---- ---- rz I B 1 '' I- 1 I 3 G ; 1- - -- --- I ; G -- I = -- 1 �- ; I t-1 I ( I; I , I._ - L1-23 - r# I! 1 a G C1 G - _ 1 I ---- -- L1-16 6p L1 16 T; I, i t==18F 1 .: „I0 8�; L1 I- ��--� _ 'r H5 1 ri I !- 'I H5A 1-18r L 18rI_ I 0 S I 3' l 1 #tr 1 I I - II # i 1 L1 - 1 I L1 -14n -� �� :,, =s ?1; E ;. Cs _;L AIR : _ �UI.AR �1 1-� _ •; r-.9UL E _ �� (= 3- Ii a 1. :°__ - _. - jj t.. - i - I 1 (=G . 1 ;' i . s �. _ r!�1 (I ; .I� v --- --- - - - - - 1G== - ; G -- _ �. 11 "7 G - 1E as ; IP t ; c, i 1-16p a 6 1�ii _ , 13 _. G=I 3 - -II H H1 ;i =a r , -20s,1# L1-16 I - ; r _ ,` I = ;gig r p. _ ;j ; �1 ! L1 # P 3 3i€ ,R I _ _ i I =:; I;U r L1 20s",, I a _=-- I I �I I 1 Ll jt5pl' 3, ijT_ , ='' - _ ffi­11ff = _r A€ . II iI U1; 1 - - -� I - 1 , - I - I P :' L1- 6 3 I , L1 I23 -..._`L1 -14n i' - - a_� �� ' _ I I } # - �.z i � � q ` 1 1 I B \f� ���_ I,R i; ,_ ;# �£ G is I �? 11, Ij E, » I L1 -16p G5_21 =G --_- L1 lop�_,1� Ll -20s j 10 II �F _ ! SE- '_ _ , =16 I 11 I -- I I Lt -14 .��1r L1 1' pI 11 I _' �I C� L1 2Qs EM 1 B C' P I H i '� _ H P I _- �' -20s 1 - „it C -- jj € _ I I = Jr I 3'= 71 34 '- - -16 ��i: st 1 >i':i i `[ ` 'ir i 'I € 4D Ii t ! , o X17 I -10 _ , -1 0�l S L1 -20s -- - . r �I 7-,m 1 1 3 I G I r 3 G r I :1 I- i -1r € 1,: S '.� - - - I }, G 1 G ' _ A 1 - 'a 1£U€ . = r,, „ 3 ;P €=L1-20 c G 131 I>�1t L1 =14n G L1 -14n I r� :1 11 "� n t=G-; , L1 -14n s` _C { li_ _ # �' L1 20s = i €1 I , 3 I i - _ i� Ll 20s (It _ I L1-14 - 1 n �, t # r r 1 � .L1 -14n � £i _ - 3� .-�` I L1 -20s L1 20s I , .. _ � L1; 14 - I,I I - ;- ,,.- - - I I > 4 I , _# _ : I, _� Is1 , r, G _rel I1 r I i - f- 1 F� T� # L`1 -14n 110 11 E }" I 1 i191, ;. ;1 _11 ! G S�L=11m:=�4i�- ,I L1 -14n 1r £ - ;I ;I 8 1 1 - i 1 .€ .� _ 1, G 1 �11 _ -- T I --- '' . G 30 I M f r Ir. _-0 - f, I � I- .. r T, I o k `25t -y - L1 -14n L1 -14n G---_-�- - _-.. r : Ll -20s = L1 -20s; L1-20sa 13 - G,� i y) kE I3r L1 -14n r� _ Lr -14n I G Ile° € jL1 1 L17toM - = $r�$p-$>-$s,R HCl®1L1= 6 -0 _, �� 3 EML1 14 1 I __-' 1- -- _ 1 L1 28aa X1 -r I L1 -20s 1111 - M-' ,I G G , € I 3 = _ E _ £ ,. EML1-20 #�. -, i , , " t . I I, - - ,. �a � L - � -r _ O , i£ 1� _ , L1 17 $ i - 1 1� 7 , r - � € ` P r=G#� L1 -25t 3 I1 , t, I�_� i— OLi 6a I I IP MID I ff-D B I - _'i �,r - , L-1��1 " - ' L 28aa , I i 1 „ 1r=14n �I G I-- �_-_ _ rDr FI(C�. = 1 1 - P� - G B B B B I0 I • -`- r j B I�6�r-i r ° n CHS I' -I rl_-28aa I- j ; - �� 'Ll'l4ri ; eft 111 = 31, G'_ 1 I rT I I 11 a .ti}I_6, EM, rLl 17 1�$1 = r==l [LrB �7r�`�t�[� FT--- 3 F; OFT1 e_ I .. # ,t #: , IL1'17I I - ,,_ 1 r - I = � €- _ , 1 17r` -ICE1 €.t -- 1 B # r € f1 1,3 �B -_ I;f # I i� = - - - I L1 117 T-,_� tAl-- F_I IV --- 3; > L1 14n ff j cLO- ' 1 I B�__ . " f _ 6 U I __ ' = I -i L R r�;,lpj6a p KQL1-19b K®L1-19b I-= I ;�% G q1-1] _ I 1 L1-17 aT `- L1-2 as 11 I I _», L1 -14n L1 -14n 3- - --t' -- I 11-28aa Ll_19b K I-1 r B B E � � I` �P-t;: 0 1. I , #i _ + L1 _ B B B B 6 U_ -.GI - s :j i I =jam,. € _, ; L w - I_ - -�` I-011 I 1� 11. 1 _ L1- 7z(11 , O �- _ 1 G ,__ x ,,- - _-�-- o =L1-1 - I L1-1-4rrm-Y�_1 �' 1� ; £ I I �jb 9b 1 1 I Ll -19a t - I- 1 C 1 1 i - L1- �7r�`�t�[� u:-- - 1 ( I I C I I I -- C -- ' II - '`#9 I I € # O ( -- I 19b€'- Ll' € !p� f K r i 1OFrI I I . -`- 1 e� EM 1 EM Ll -6-� __� d . - Is B i I - i 1 I L1 -14n L L� EAST/ : •.r ¢ Lz ' -- F N LLU 2#10, 10G, 1/2"C ,. T F — ---- - - --- --- - €j P3-37 EF 3 ToW3=37� r 1 P3-6; MDP 42=`F' ( ' - _ - - METER STATION _ :- F - P3-36 P3-37 & CT CABINET SEE RISER DIAGRAM.- � ' n n �t sa� F tt T PHOTOCELL "PC -1 " j PF2 T3 PANE P1 € _ R r F €� PANEL P2 P2=2E, !J ! CE 01 L1-29 `Ia _ P`I � � j1-2 PANEL MDP i P2 6 P2=2 P1-2 - 56 - r P3-6 �. PA I HofzA €T_i I PNL1 L1 LIGHTING CONT. "LC -1 - -;PT 4-- P12T_P1=12- -�"- 1 11€ _ - TTB RTU -4 P1 4'�-€�'(EXISTINGI' 0 L1-29' ION ROOFS �-P1 �oP1 42 ! SD t 1P2 - P1 4 s i3 P1 -4l P2-3 I�P-36 FACP - P2 33 E _ �� VJr _ AR2 3 - T lb@ P2__=36 P2�, it P1-6 € 3P 60A/NF r= 1 MDP -8/10/12 --,_ 3 , 6€ 10G€ 3/4"C M, s �P1,�56 € 4 P1 -6E( Al ' �P3T3 , P31 -_ P3=1---� P3=3 - -TP3= €I € . 2n0 1R I I ?o R2. _33 iR I) . P1 __30� _ I� i�','r10EP P1 P1-30 fII fl P1-30 i Cr'15 F 9 P1 30 1 f EWH-1 (EXISTING) -�1 r - 1 r 1 P3-35-3.5 r M OF I U- ; `U''- ` 1 Q3=35 = P3-35 P3-37 ; L P3-26 (REFRIGERATORS) 3 ENST/ tf F^ r F=_ M- 00� -'r 3 - -' 7l ` 140 I II; i ' rP1=16 €€ M P2 27-�� P=2 29 I' y a !LR P 1 616 I _ __� I € €• - P27 - P-2 29 -- P-1 16 �t _3 P 2 M 9 ? 7 3 = 4 , _ �r - I ff ff„ j - ALU t1U L - v I I P1 =t6 1 P1=14 .Q, - - C�F1 J�ug I�P1r�81FIT�8��P1-181 14 ?�P2 3i 2 31®e ? I€ _ i. _ -P2 3T I ;, 'P1: 1 t F €ml z --_4P 32 ,--;�14 l 1 i 0 2P/60A/NFP1 18 4 T/ WEST I - 1Q .. MDP _38 40 - - ,j- 100 -_ 3#8, l OG, 3/4°C - - - - - - - --131D l F = T - ri •,r P3 -24 (DISHWASHER) P3-20 (DISPOSAL) 7---P3-18 (MICROWAVE) i F € 11 �€111 t 1 r l€ e II�I11� € € a I€ [C'N TU 6 i P2-37 �ROOF' I IOWP/G 1 =3 9 P1 =39 r I ; 1 �A , 1 VAV-4 T 3r P 1=37 P1,37 {r €il X37 P1 P1 -39 I I I I I I I I I I I I I IF IF 3P/60A/NF ' MDP -20/22/24" 3#6, #10G, 3/4 C 'll €II `II ItI II[ I[I �— — l I r I 1 I 4 I� I �I i -5 r —rt €II 3 s P2 3 �1 J I I , 0 € II i -1 312y = rr s1a3 �_ E' �F" I �T; { I• SP1 -32 - tl P1-20 - F. u _ I moi,:R= F _ _ P iW _ �;3'-t0TV � P 1 22+ R1 20 - d -- .04 _€P1-32 r -� � __- 1r�_'I EF�VI k I ,€ ;,- iP €1_ _�'2-=•15 € - i I i - II - -T131- rPa _� I��T , tea€= €I FB -4 I = L = P1r20 P1 22 �'CI?�rP12rI t `-�- I� = z 3 I € _� SP1 -34 i- 20 P 1 224 P�� '�1 -e 3-10 = P=1'34 11 4 {� -- _ 1 � *,-�P ,19 - 'j' Tff2 �y N110 DU r 1 P1 2Q z..P X22 t -__ P 24 €ter r t :�` = � T fl � - IO" _ �. - --- I F - . f. .} F - I ��2P -60A F _� �r , _ ; , - __ -___ _-- - F 2 -1,7 , ,�,_ _ �2 19� -- ,-_--�-r--�`� --- - T, - � r- P1 34 , 1� 1 34 _ T- :l.s .WA F SP1 -36 i_ 1MDP3/3,61- ; uu , - _ s ��Y I ! P3 6 S. 1r ' I C3#8�_`#l.G�E3/4'C_ P1 -34t ( ,f D j - ��.� �, �,r, (�br ' [ j��.�' j RTU -3 T' € ri I __--_1�fFg3_ C, P1-7s1t=SD�1�N ROOF,; :I -'_-= I Pl / _- 3,€ 1 €,F! _, =5 -z, T P_1 T9 WP/G1 ' a — s R m tT IF T I I I P-136 - SP1==36 t X26 _ II I SP1 -21 v __ r ,Lwp -€ 3P 200A NF1 -� Z� P1-24 P3 -3i i I ' P2� '- P1-19� I d� ire; ( li , — /29 i1,� --F F I'O € _ _'� f`'.:}r¢g �U1 13 €#€=� -€F € C i U5 4e € -- 1 r () r' r' s DP 27if =1 �' _ II 3 2, 6G, 1 1 C {� I P1 _ E'rlri-2 I G '�;` I £ / =' ` - €�W _ -� L ; I ' I i TI t a 31 Tom" �; -I if 3 z - _ ;3-12 I P -2"0 -24 ;1 = U i,r� = 3 i _Pr,-- € RTU -1 i SD~ -_---I - r -�-- _� _ i 1_: P1 r,> € _ �P4—_.F !Er ,;-tel lr=_€, ..IP13-21I , _ i� _ 3 •tee OP 1 t �.� _ I[ - —_ n_ f = ' - = I rr K i r , ,-�-_ , _ --_• __.-_. - - S€ - I 2-_-271 - -..F = _ 1 31 - _ r� , P1 24 _ P2- 2-1 A , r_,� I 3P1 99� _ ON ROOT ! I 1 = P3-28 : ; , 3,,,� I t=; r t �, '3 =r I P 1 13 P1. 7 l !_ _; }; I P2=21P2=21--- I P1 36 - J IFG— 12 - L- _ 1 2P/100A/NF 3P/100A/NF I`� _ z, P1-26 11- - _ - _ _ z P1 17 i „�-y 1i L P1- 3 MDP -26 28 I€ MDP -1; 15 17 ! ;� ,,,- / : _ Pi _ P1-38 / /_ EF -2_ ?,F�,-G`;T2I€VAV=1 `SP1 -21 L: 3#3, #8G, 1 1/4 C �I 3#4, #SG, 1 C P3 6riA1 _23 I _ 1_ I --- I_V_ FERT 1 _ _ u FB --t _ i £=� FB. -72. P1-38�P2€I5 P W26 ' '� L t 1 'AUC (- .; _nom P3-4 J 1 g j =I I G -..� i t� _ }j}j - _ ;-_...`F_.. .�-r-_`—•, �'[ i S € _ -- r��€€I��€�� -P1 —11 II€ x ?®P 1- 38 1 ° = - --' -=--- j €. P 1 21 = k -1I€,� .�`4 i{ 1� _ €° I! P1-.2Li _ i °VAV 2 RTU -2 r P1-17 1�€IP-19/21/23- 1 i- — - I'3rP I E r. _ - �' - - _ (r , r----�ON OOr -� 3#3, #8G _1 /4 Pl 26 1 _,_ � , F � P1 28 E i "�. I ` l - P,1 X11_ _ --- _ -— _ _ - --- - _ � — ;, u—u , -MDR=30/32 :� I m F 6 - }1=' - R C - tW P1 17 f- „max :_ _ n L � S � � =;1 � P 1-23 _I P 121 _ =P 1 15-t- - -- - _ 3# � #BGF= 1I . H ' _P2 ;2 _, =3 11 i __ SD - -_, �- 1P x P � 8�P -23 - :; _ 1_- :; P1-7 rl _4�1 PT 1l - ;' ;tr , ,I r r tr _ _ ^,pq _ P - l t= '_� i i ; �IF� r! . - , , _ ,�- i _ _I 31 13`- j� acv-un=:,,r—w.�.€� _ ._��a_ =( _ a 1 €-, _ _ _ _ _ r �3 r _ ' = P1-2�r` t1`t F ' _ _ - drr 1 - , 0� n� I r �€ - -� _ _ ERF �- - � -n P1-28_ , _, °__r _ 1 _ _ , - 1 t?®P1=1 1 I 0�����.,�f'1�� � �--- .� a=f�� ___ _ �� 1_�- P1-23 _.=`= P3 8��_� L§-�- - � ��' P1 17 P1 —38 ,-s i I�1 ��; i L - -I 8 _ - - 3 € r� i `, = �� _ _'� ) -P1=23 t-'' € `5 P - - 1 tW 2 _ �€ F If P -28 f ��WST 11-= 3 -404 1 P1-15 s _ 5� I An? iii r—f _11 _ _ �� -:� T = -- _ - t. FAA r _ 1 _ F)IP1 _ -�P3 1.911 j 1 - ;;S;s• F =_ 3 i ! I Vis} lioPl 38 ( - _sl€° �;€„€ A;€—) _ PI --i 3 � 1 �I 1�_;— — t-€ -=tom — Il P34:Er_ I,� 1-1 SP1 _�,vE1 SP1°'3f1j'f'?1 3 �P1 3�,.'3P1 5 -s_ =- - 1 - - > - _ - ' . - € _....._ - t i 1 =_' i a l � j; 1I�` y�� t r 3 j I _ F, I I � .I i. I3 `I v T_€ _- _ - - ;I - P1 3 - P= -38 , : , ,__ i�-P-1 40 � -_ _ _ ;€ P�1 40 f € I� F11 40 1 i _' `' � � � l P1 1 �;, 3P1 1 �P1 3 e }: I F 4 �f — Ste' — - i' € I�.� _ _ — _ - I - _IV } _S. I i , 1 I -c ,PT 10= I FIRST FLOOR PLAN - POWER & I� ' E I l I I I I I 1 rEms SCALE: 11T=1 =1 -0 GENERAL NOTES 1. REFER TO GENERAL NOTES SHEET E-0.1. 2. AT HIS DISCRETION, CONTRACTOR MAY REUSE EXISTING CONDUIT, FITTINGS, AND BOXES WHICH ARE FREE FROM DEBRIS AND CORROSION, AND ARE CONSIDERED IN "LIKE -NEW” CONDITION. WHERE EXISTING CONDUIT ROUTING DOES NOT ACCOMMODATE INSTALLATION OF NEW WORK, NEW CONDUIT SHALL BE INSTALLED. EXISTING CONDUCTORS/WIRING SHALL NOT BE REUSED. 3. FOR ANY PANELBOARD TO BE REUSED, REVISE CIRCUIT DIRECTORY TO REFLECT ALL CHANGES AND ADDITIONS. 4. FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND EQUIPMENT POINT OF CONNECTION, REFER TO MECHANICAL DRAWINGS AND MANUFACTURER'S SHOP DRAWINGS. 5. ALL CIRCUIT FEEDERS AND DISCONNECTS SHALL BE SIZED PER REQUIREMENTS OF NATIONAL ELECTRICAL CODE. CONTRACTOR IS TO VERIFY DISCONNECT SWITCH AND FUSE SIZES WITH SELECTED EQUIPMENT MANUFACTURER'S SHOP DRAWING PRIOR TO PLACING ORDER AND PROVIDE EVERYTHING AS REQUIRED. KEY NOTFS O VERIFY EXACT ELECTRICAL REQUIREMENTS OF EXISTING HVAC EQUIPMENT TO BE REUSED AND MAKE ANY CHANGES AS MAY BE NECESSARY. P Copyright 2004 ACi, Inc. HSA HUMAN SERVICES ASSOCIATES, INC. C� lllc:� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i AS S O C -LATER CONS ULTIN G INTERN fl1'I ONJA L DEVELOPi�iENT.f�Ii' NAGENIENT.ARCIUTECTURE FL AA0002940 955 N. PENNSYLVANIA.AVE. W'INTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 F-,tX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusirely to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. B `L P3-22 P3-164 144 '(COFFEE MA.� �01) 1 F 3 !!- P3-164EH N 0060 BEESNNG. E 5 P1-9 i F € 11 �€111 t 1 r l€ e II�I11� € € a I€ [C'N TU 6 i P2-37 �ROOF' I IOWP/G 1 =3 9 P1 =39 r I ; 1 �A , 1 VAV-4 T 3r P 1=37 P1,37 {r €il X37 P1 P1 -39 I I I I I I I I I I I I I IF IF 3P/60A/NF ' MDP -20/22/24" 3#6, #10G, 3/4 C 'll €II `II ItI II[ I[I �— — l I r I 1 I 4 I� I �I i -5 r —rt €II 3 s P2 3 �1 J I I , 0 € II i -1 312y = rr s1a3 �_ E' �F" I �T; { I• SP1 -32 - tl P1-20 - F. u _ I moi,:R= F _ _ P iW _ �;3'-t0TV � P 1 22+ R1 20 - d -- .04 _€P1-32 r -� � __- 1r�_'I EF�VI k I ,€ ;,- iP €1_ _�'2-=•15 € - i I i - II - -T131- rPa _� I��T , tea€= €I FB -4 I = L = P1r20 P1 22 �'CI?�rP12rI t `-�- I� = z 3 I € _� SP1 -34 i- 20 P 1 224 P�� '�1 -e 3-10 = P=1'34 11 4 {� -- _ 1 � *,-�P ,19 - 'j' Tff2 �y N110 DU r 1 P1 2Q z..P X22 t -__ P 24 €ter r t :�` = � T fl � - IO" _ �. - --- I F - . f. .} F - I ��2P -60A F _� �r , _ ; , - __ -___ _-- - F 2 -1,7 , ,�,_ _ �2 19� -- ,-_--�-r--�`� --- - T, - � r- P1 34 , 1� 1 34 _ T- :l.s .WA F SP1 -36 i_ 1MDP3/3,61- ; uu , - _ s ��Y I ! P3 6 S. 1r ' I C3#8�_`#l.G�E3/4'C_ P1 -34t ( ,f D j - ��.� �, �,r, (�br ' [ j��.�' j RTU -3 T' € ri I __--_1�fFg3_ C, P1-7s1t=SD�1�N ROOF,; :I -'_-= I Pl / _- 3,€ 1 €,F! _, =5 -z, T P_1 T9 WP/G1 ' a — s R m tT IF T I I I P-136 - SP1==36 t X26 _ II I SP1 -21 v __ r ,Lwp -€ 3P 200A NF1 -� Z� P1-24 P3 -3i i I ' P2� '- P1-19� I d� ire; ( li , — /29 i1,� --F F I'O € _ _'� f`'.:}r¢g �U1 13 €#€=� -€F € C i U5 4e € -- 1 r () r' r' s DP 27if =1 �' _ II 3 2, 6G, 1 1 C {� I P1 _ E'rlri-2 I G '�;` I £ / =' ` - €�W _ -� L ; I ' I i TI t a 31 Tom" �; -I if 3 z - _ ;3-12 I P -2"0 -24 ;1 = U i,r� = 3 i _Pr,-- € RTU -1 i SD~ -_---I - r -�-- _� _ i 1_: P1 r,> € _ �P4—_.F !Er ,;-tel lr=_€, ..IP13-21I , _ i� _ 3 •tee OP 1 t �.� _ I[ - —_ n_ f = ' - = I rr K i r , ,-�-_ , _ --_• __.-_. - - S€ - I 2-_-271 - -..F = _ 1 31 - _ r� , P1 24 _ P2- 2-1 A , r_,� I 3P1 99� _ ON ROOT ! I 1 = P3-28 : ; , 3,,,� I t=; r t �, '3 =r I P 1 13 P1. 7 l !_ _; }; I P2=21P2=21--- I P1 36 - J IFG— 12 - L- _ 1 2P/100A/NF 3P/100A/NF I`� _ z, P1-26 11- - _ - _ _ z P1 17 i „�-y 1i L P1- 3 MDP -26 28 I€ MDP -1; 15 17 ! ;� ,,,- / : _ Pi _ P1-38 / /_ EF -2_ ?,F�,-G`;T2I€VAV=1 `SP1 -21 L: 3#3, #8G, 1 1/4 C �I 3#4, #SG, 1 C P3 6riA1 _23 I _ 1_ I --- I_V_ FERT 1 _ _ u FB --t _ i £=� FB. -72. P1-38�P2€I5 P W26 ' '� L t 1 'AUC (- .; _nom P3-4 J 1 g j =I I G -..� i t� _ }j}j - _ ;-_...`F_.. .�-r-_`—•, �'[ i S € _ -- r��€€I��€�� -P1 —11 II€ x ?®P 1- 38 1 ° = - --' -=--- j €. P 1 21 = k -1I€,� .�`4 i{ 1� _ €° I! P1-.2Li _ i °VAV 2 RTU -2 r P1-17 1�€IP-19/21/23- 1 i- — - I'3rP I E r. _ - �' - - _ (r , r----�ON OOr -� 3#3, #8G _1 /4 Pl 26 1 _,_ � , F � P1 28 E i "�. I ` l - P,1 X11_ _ --- _ -— _ _ - --- - _ � — ;, u—u , -MDR=30/32 :� I m F 6 - }1=' - R C - tW P1 17 f- „max :_ _ n L � S � � =;1 � P 1-23 _I P 121 _ =P 1 15-t- - -- - _ 3# � #BGF= 1I . H ' _P2 ;2 _, =3 11 i __ SD - -_, �- 1P x P � 8�P -23 - :; _ 1_- :; P1-7 rl _4�1 PT 1l - ;' ;tr , ,I r r tr _ _ ^,pq _ P - l t= '_� i i ; �IF� r! . - , , _ ,�- i _ _I 31 13`- j� acv-un=:,,r—w.�.€� _ ._��a_ =( _ a 1 €-, _ _ _ _ _ r �3 r _ ' = P1-2�r` t1`t F ' _ _ - drr 1 - , 0� n� I r �€ - -� _ _ ERF �- - � -n P1-28_ , _, °__r _ 1 _ _ , - 1 t?®P1=1 1 I 0�����.,�f'1�� � �--- .� a=f�� ___ _ �� 1_�- P1-23 _.=`= P3 8��_� L§-�- - � ��' P1 17 P1 —38 ,-s i I�1 ��; i L - -I 8 _ - - 3 € r� i `, = �� _ _'� ) -P1=23 t-'' € `5 P - - 1 tW 2 _ �€ F If P -28 f ��WST 11-= 3 -404 1 P1-15 s _ 5� I An? iii r—f _11 _ _ �� -:� T = -- _ - t. FAA r _ 1 _ F)IP1 _ -�P3 1.911 j 1 - ;;S;s• F =_ 3 i ! I Vis} lioPl 38 ( - _sl€° �;€„€ A;€—) _ PI --i 3 � 1 �I 1�_;— — t-€ -=tom — Il P34:Er_ I,� 1-1 SP1 _�,vE1 SP1°'3f1j'f'?1 3 �P1 3�,.'3P1 5 -s_ =- - 1 - - > - _ - ' . - € _....._ - t i 1 =_' i a l � j; 1I�` y�� t r 3 j I _ F, I I � .I i. I3 `I v T_€ _- _ - - ;I - P1 3 - P= -38 , : , ,__ i�-P-1 40 � -_ _ _ ;€ P�1 40 f € I� F11 40 1 i _' `' � � � l P1 1 �;, 3P1 1 �P1 3 e }: I F 4 �f — Ste' — - i' € I�.� _ _ — _ - I - _IV } _S. I i , 1 I -c ,PT 10= I FIRST FLOOR PLAN - POWER & I� ' E I l I I I I I 1 rEms SCALE: 11T=1 =1 -0 GENERAL NOTES 1. REFER TO GENERAL NOTES SHEET E-0.1. 2. AT HIS DISCRETION, CONTRACTOR MAY REUSE EXISTING CONDUIT, FITTINGS, AND BOXES WHICH ARE FREE FROM DEBRIS AND CORROSION, AND ARE CONSIDERED IN "LIKE -NEW” CONDITION. WHERE EXISTING CONDUIT ROUTING DOES NOT ACCOMMODATE INSTALLATION OF NEW WORK, NEW CONDUIT SHALL BE INSTALLED. EXISTING CONDUCTORS/WIRING SHALL NOT BE REUSED. 3. FOR ANY PANELBOARD TO BE REUSED, REVISE CIRCUIT DIRECTORY TO REFLECT ALL CHANGES AND ADDITIONS. 4. FOR EXACT LOCATIONS OF MECHANICAL EQUIPMENT AND EQUIPMENT POINT OF CONNECTION, REFER TO MECHANICAL DRAWINGS AND MANUFACTURER'S SHOP DRAWINGS. 5. ALL CIRCUIT FEEDERS AND DISCONNECTS SHALL BE SIZED PER REQUIREMENTS OF NATIONAL ELECTRICAL CODE. CONTRACTOR IS TO VERIFY DISCONNECT SWITCH AND FUSE SIZES WITH SELECTED EQUIPMENT MANUFACTURER'S SHOP DRAWING PRIOR TO PLACING ORDER AND PROVIDE EVERYTHING AS REQUIRED. KEY NOTFS O VERIFY EXACT ELECTRICAL REQUIREMENTS OF EXISTING HVAC EQUIPMENT TO BE REUSED AND MAKE ANY CHANGES AS MAY BE NECESSARY. P Copyright 2004 ACi, Inc. HSA HUMAN SERVICES ASSOCIATES, INC. C� lllc:� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i AS S O C -LATER CONS ULTIN G INTERN fl1'I ONJA L DEVELOPi�iENT.f�Ii' NAGENIENT.ARCIUTECTURE FL AA0002940 955 N. PENNSYLVANIA.AVE. W'INTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 F-,tX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusirely to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. B A BORES ASSOCIATES CONSULTING ENGINEERS 150 CIRCLE DRIVE MAITLAND, FL 32751 638.7024 �0 N 0060 BEESNNG. E 5 FLO RDA4 Issues and Revisions No. Date Issue/Revision By 1 02/23/05 VE / REVISION WMC Date: November 30, 2004 Checked By: NWMC Drawn By: TT Project No.: 0416 File Name: _2010416.dwg Phase: PERMIT DOCUMEN Sheet Mame: FIRST FLOOR & MEZZANINE PLANS - POWER SHEET NUMBER i InIAN SERVICES ASSOCIATES, INC 0 CD S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC /0 ASSOCIATED CONSULTING INTERNA 1102NAL ® ® 0 DEVELOPMENT. TbL NAGEMENToARCHITECTURE FL AA0002940 955 N. PENNSYLVANLA AVE. 1 h\1TERPARK,FLORIDA 32789 USA PHONE: (407) 740-8405 FAY: (407) 74M406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI. Inc. Any unauthorized use, dis— closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laxs. B ❑ A ❑ BOBLSASSOCIATES w. ]EN C� 1 Gw7 CONSULTING ENGINEERS Issue/Revision By 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628.7024 02/23/05 VE / REVISION C E E --MAIL: INFO*BOBESENG.COM File Name: _2010416.dwg FLORIDA STATE P.E. NUMBER: 5131 Issues and Revisions No. Date Issue/Revision By 02/23/05 VE / REVISION WMC Project No.: 0416 File Name: _2010416.dwg Phase: PERMIT DOCUA ENT , Sheet Name: Date: November 30, 2004 Checked By: NIC Drawn By: TT Project No.: 0416 File Name: _2010416.dwg Phase: PERMIT DOCUA ENT , Sheet Name: PANEL SCHEDULES & RISER DIAGRAM SHEET NUMBER E— 3,o HUM1 AN SERVICES ASSOCIATES, INC. 0 C� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida Ac 2 ASSOCIATED CONS ULX1NG INTERNATIONAL ® ® • DEVELOP,MENT.1\111 \'AGEN EMT -ARCHITECTURE FL AA0002940 955 N. PENNSYLVANIA AVE. WINTER PARK, FLORIDA 32789 USA PHONE: (407)" 40-8405 FltX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis— closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. B ❑CONsW NG ENG ]�Y S A CONSULTING ENG�*�'�'p+a 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628.7024 {: )� E—MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 Issues and Revisions No. Date Issue/Revision By Date: November 30, 2004 Checked By: NX/MC Drawn By: TT Project No.: 0416 File Name: _1010416.dwg Phase: PERMIT DOCUNtENT Sheet Name: FIRST FLOOR AND MEZZANINE PLANS DEMOLITION - ELEG SHEET NUMBER L L VENTILATION SCHEDULE H. LDiNG CFM 20 CHS OFFICE #2 156 1 LOCATION NO. PEOPLE CFM/PERSON CFM CONFERENCE RM #7 168 14 10 CFM 140 CONFERENCE RM #8 169 14 10 CFM 140 CONFERENCE RM #9 171 75 10 CFM 750 TOTAL -� f - 680 RTU -4 VENTILATION 1030 RTU -1 VENTILATION PRESSURE 700 HIGH BAY MODULARS 141 (CENTER) 1050 LOBBY 101 2 20 CFM 40 CBCS RECEPT,/WAIT. 102 10 20 CFM 200 CLWS RECEPTION 111 4 20 CFM 80 CLWS OFFICE #1 112 2 20 CFM 40 CLWS OFFICE #2 113 2 20 CFM 40 CLWS OFFICE #3 114 2 20 CFM 3 40 TOTAL 20 CHS OFFICE #6 162 I 1 440 RTU -2 VENTILATION 20 TOTAL MANUAL RIR VENT 450 CBCS OFFICE #1 103 2 20 CFM 40 CBCS OFFICE #2 104 2 20 CFM 40 CBCS OFFICE #3 105 2 20 CFM 40 CBCS FILE ROOM 106 1 20 CFM 20 CBCS FAMILY ROOM 107 6 20 CFM 120 CLWS OFFICE #3 114 2 20P CFM 40 CBCS FILE ROOM 106 1 20 CFM 20 CBCS FAMILY ROOM 107 6 20 CFM 120 CLWS OFFICE #4 115 2 20 CFM 40 CLWS OFFICE #5 116 2 20 CFM 40 CLWS OFFICE #6 117 2 20 CFM 40 CLWS WORK ROOM 118 4 20 CFM 80- CLWS CONFERENCE RM 121 6 20 CFM 120 CONFERENCE RM #1 122 14 10 CFM 140 STEINS'S OFFICE 124 2 20 CFM 40 M.H. MODULAR 127 8 20 CFM 160 CONFERENCE RM #4 164 2 20 CFM 40 CONFERENCE RM #5 165 2 20 CFM 40 CONFERENCE RM #6 166 2 20 CFM 40 CBCS MODULAR 172 2 20 CFM 40_ TOTAL 2 20 CFPA 1260 RTU -3 VENTILATION1300 2 20 CFM 40 CHS OFFICE #1 155 1 20 CFM 20 CHS OFFICE #2 156 1 20 CFM 20 CHS OFFICE #3 157 1 20 CFM 20 CHS OFFICE #4 158 1 20 CFM 20 HIGH BAY MODULARS 141 (WEST) 30 20 CFM 600 TOTAL KITCHEN AIR SUPPLY UNIT DUCT UNDER POSITIVE -� f - 680 RTU -4 VENTILATION BTU BRITISH THERMAL UNIT PRESSURE 700 HIGH BAY MODULARS 141 (CENTER) 14 20 CFM 280 LOW BAY MODULARS 142 16 20 CFM 320 I&P OFFICE 131 1 20 CFM 20 FB/ICCP OFFICE 132 1 20 CFM 20 HSA OFFICE #5 160 1 20 CFM 20 NSA OFFICE #6 161 1 20 CFM 20 CHS OFFICE #5 163 1 20 CFM 20 CHS OFFICE #6 162 I 1 20 CFM 20 TOTAL MANUAL RIR VENT ®-+- RETURN OR EXHAUST AIR`- 720 RTU -5 VENTILATION T ----- -r LINEAR DIFFUSERS -(] 700 FC/HRNB/TCM MODULARS 14 20 CFM 280 MENTAL HEALTH OFFICE 128 1 20 CFM 20 CONFERENCE ROOM #2 129 18 10 CFM 180 WIS-FIS OFFICE #1 133 1 20 CFM 20 WIS-FIS OFFICE #2 134 1 20 CFM 20 WIS-FIS OFFICE #3 135 1 20 CFM 20 TCM OFFICE 137 1 20 CFM 20 CONFERENCE ROOM #3 138 6 20 CFM 120 TOTAL ® AD DUCT ACCESS DOOR -Q 680 RTU -6 VENTILATION SENSOR SUPPLY AIR PIPE ELBOW 700 DAVID'S OFFICE 142 2 20 CFM 40 BREAKROOM 144 8 20 CFM 160 HSA OFFICE #1 145 2 20 CFM 40 HSA OFFICE #2 146 2 20 CFM 40 HSA OFFICE #3 152 2 20 CFM 40 HSA OFFICE #4 154 2 20 CFM 40 FB-ICCP MODULARS 2 20 CFM 40 TCM MODULARS #8 & 9 2 20 CFM 40 HEALTH FAM. OFFICE #1 201 2 20 CFM 40 HEALTH FAM. OFFICE #2 202 2 20 CFPA 40 HOME MER OFFICE 204 2 20 CFM 40 HOME .MAKER MODULES 2 u 20 CFM 40 HEALTH FAMILIES MODULES 14 20 CFM 280 TOTAL 880 AHU-2 VENTILATION 900 HVAC CENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA MECHANICAL_ CODE WITH 2002 AND 2003 REVISIONS, 2001 FLORIDA ENERGY EFFICIENCY CODE AND THE ORANGE COUNTY BUILDING DEPARTMENT REQUIREMENTS AND ALL OTHER APPLICABLE CODES AND STANDARDS. MECHANICAL ROOMS, LOCATIONS AND SIZES OF BEAMS AND CEILING AND SOFFIT HEIGHTS. 5. DUCTWORK AND EQUIPMENT LOCATIONS AND CLEARANCES SHALL BE COORDINATED WITH GENERAL, PLUMBING AND ELECTRICAL CONTRACTORS. REFER TO ARCHITECTURAL PLANS FOR BUILDING SECTIONS AND DETAILS. 6. CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURERS CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR ALL EQUIPMENT FURNISHED. 7. COORDINATE DIFFUSER, REGISTER AND GRILLE LOCATION WITH LIGHTING, SPRINKLER AND ARCHITECTURAL CEILING PLANS. ALSO COORDINATE THE TYPE OF DIFFUSER FRAME WITH THE CEILING TYPE. 8. ALL HVAC SYSTEMS SHALL BE BALANCED FOR AIR QUANTITIES SHOWN AGAINST THE ACTUAL INSTALLED STATIC PRESSURE OF THE SYSTEM. CONTRACTOR SHALL PROVIDE POSITIVE MEANS FOR BALANCING EACH INDIVIDUAL AIR OUTLET AND INLET. 9. ALL EQUIPMENT SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING VIBRATION ISOLATORS PADS. ALL CONNECTIONS BETWEEN AIR HANDLING EQUIPMENT AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 10. EVERY APPLIANCE AND ALL MECHANICAL EQUIPMENT SHALL BE LOCATED WITH RESPECT TO BUILDING CONSTRUCTION AND OTHER EQUIPMENT SO AS TO PERMIT ACCESS TO THE MECHANICAL EQUIPMENT IN CONFORMITY WITH ANY CLEARANCE WHICH MAY BE RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT. SUFFICIENT CLEARANCE SHALL BE MAINTAINED FOR CLEANING COILS, MOTORS, BURNERS, AS WELL AS CHANGING FILTERS. ALL EQUIPMENT SHALL BE LOCATED WITHIN THE MECHANICAL ROOM AND CEILING SPACES WITH ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE, ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. INSTALLATION OF ALL MECHANICAL EQUIPMENT SHALL COMPLY WITH THE MANUFACTURERS SPECIFICATION AND CLEARANCE REQUIREMENT. 11. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. 12. THE INSIDE OF ALL DUCTS VISIBLE THRU THE FACE OF DIFFUSERS, REGISTERS, AND GRILLES SHALL BE PAINTED FLAT BLACK WITH NON TOXIC PAINT. 13, OUTSIDE AIR AND EXHAUST AIR DUCTWORK SHALL BE GALVANIZED STEEL SHEETS. FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH LATEST EDITION OF SMACNA DUCT CONSTRUCTION STANDARDS FOR A 2 INCH PRESSURE CLASSIFICATION. 14. FLEXIBLE DUCTWORK SHALL BE INSULATED VINYL TYPE (R-6) WITH WIRE SPIRAL SUPPORT. FLEXIBLE DUCTWORK SHALL BE RUN IN MAXIMUM LENGTHS OF 14'-0". FLEXIBLE DUCTWORK SHALL BE PROPERLY SUPPORTED WITH GALVANIZED STEEL_ STRAPS 2" WIDE AND SHALL BE RUN AS STRAIGHT AS POSSIBLE WITH ND KINKS OR BENDS TO RF_STRICT AIRFLOW. 15. ALL SUPPLY AIR AND RETURN AIR DUCTWORK SHALL BE FIBERGLASS DUCTBOARD (R-6). 16. ALL DUCT JOINTS SHALL BE SEALED WITH APPROVED MASTIC. 17. ALL FIBROUS GLASS INSULATION JOINTS, SEAMS AND CONNECTIONS SHALL BE CONSTRUCTED WITH PRESSURE SENSITIVE TAPE, FAB, STAINLESS STEEL STAPLES AND THEN SEALED WITH MASTIC. HEAT AND PRESSURE SENSITIVE TAPE ARE NOT ACCEPTABLE AS A FINAL CLOSURE. 18. PROVIDE HANGER STRAPS FOR ALL DUCTS MADE OF 2" WIDE, 22 GAGE GALVANIZED STEEL - SPACED ACCORDING TO SMACNA STANDARDS AND ALL OTHER APPLICABLE GOVERNING CODES AND STANDARDS. 19. ALL DUCT BRANCH TAKE OFFS FROM MAIN DUCT FOR INDIVIDUAL AIR OUTLETS, INLETS AND BOXES SHALL_ HAVE BALANCING DAMPERS. 20 ALL DUCTWORK STORED ON SITE OR ALREADY INSTALLED SHALT_ HAVE ALL OPEN ENDS SEALED WITH VISQUINE TO PREVENT DUST AND DEBRIS FROM ACCUMULATING INSIDE OF THE DUCTWORK. INTERIORS OF ALL DUCTWORK SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION. 21. ALL DAMPERS AND EXTRACTORS SHALL HAVE LOCKING QUADRANTS AND SHALL BE ACCESSIBLE. 22. PROVIDE REMOTE VOLUME DAMPER OPERATORS IN ALL NON -ACCESSIBLE CEILINGS. EQUAL TO YOUNG REGULATOR COMPANY MODEL 270-896C BOWDEN CABLE CONTROL UNIT. 23. BEVELED TAKE OFFS AND DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTWORK LEADING FROM MAIN TRUNK LINES. 24. ALL SPLITTER DAMPERS SHALL BE BALANCED AND SET PRIOR TO THE INSTALLATION OF THE CEILING. 25. PROVIDE ADJUSTABLE PULLEYS WITH CONSTANT VOLUME AIR HANDLING UNITS AND BELT DRIVE FANS. 26, EXHAUST FAN OUTLETS SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM FRESH AIR INTAKES OF MECHANICAL EQUIPMENT AS WELL AS ALL OPERABLE WINDOWS AND DOORS, 27. ALL FANS AND AIR HANDLING UNITS SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING ISOLATORS. ALL CONNECTIONS BETWEEN FANS OR AIR HANDLING UNITS AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 28. ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACES SHALL HAVE ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE. ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. 29. ALL AIR HANDLING UNITS SHALL BE MOUNTED ON STEEL SKIDS. 30. REFER TO MECHANICAL AND ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE AND SMOKE RATED PARTITIONS. ALL PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS OR FLOORS AND CEILINGS SHALL HAVE FIRE/SMOKE DAMPERS. ALL FIRE WALL PENETRATIONS SHALL HAVE FIRE DAMPERS. PROVIDE ACCESS DOORS IN WALL OR HARD CEILING FOR THESE DAMPERS. 31. PROVIDE ACCESS DOORS (24"x24") FOR ALL FIRE/SMOKE DAMPERS AND FIRE DAMPERS IN NON -ACCESSIBLE CEILINGS, 32. PROVIDE ACCESS PANELS IN DRYWALL CEILINGS AS REQUIRED FOR ACCESS TO MECHANICAL EQUIPMENT. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE WORK PLATFORMS AS REQUIRED FOR ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACE. 33. FURNISH AND INSTALL INSULATED COPPER OR PVC CONDENSATE DRAINS WITH TRAPS FOR ALL ROOFTOP UNIT COOLING COILS. RUN CONDENSATE DRAIN LINE ALONG ROOF TO NEAREST ROOF DRAIN. PROVIDE SUPPORT EVERY 5'-0" O.C. 34. FURNISH AND INSTALL INSULATED PVC CONDENSATE DRAINS WITH TRAPS FOR ALL AIR HANDLING UNIT COOLING COILS. 35. ALL PIPING SHALL BE FULLY SUPPORTED THE ENTIRE LENGTH AND ANCHORED TO PREVENT SWAY AND VIBRATION, 36. DIVISION 16 CONTRACTOR SHALL SUPPLY AND WIRE ALL SMOKE DETECTORS IN THE SUPPLY AIR DUCTWORK OF ALL AIR HANDLING UNITS 2000 CFM AND ABOVE TO SHUT DOWN THE FANS IN THE EVENT OF A FIRE. DUCT SMOKE DETECTOR SHALL BE OF PHOTOELECTRIC TYPE AND LOW VOLTAGE. DIVISION 15 CONTRACTOR SHALL INSTALL ALL SMOKE DETECTORS, 37. ALL WALL SENSORS, VARIABLE SPEED CONTROL SWITCHES, ON-OFF SWITCHES AND MOTOR STARTERS SHALL BE INDIVIDUALLY LABELED. LABELS SHALL INDICATED THE UNIT CONTROLLED, TYPE OF CONTROL AND AREA SERVED. THE LABELS SHALL BE PLASTIC LAMINATE, PERMANENT TYPE, WHITE WITH BLACK LETTERING, AND SHALL BE MOUNTED INSIDE OF THE COVER PLATE, OF THE CONTROL DEVICE. 38, ALL ROOF MOUNTED FANS AND PACKAGE A/C UNITS SHALL BE BOLTED DOWN TO ROOF CURB USING 1/4" STAINLESS STEEL BOLTS EVERY 12" INCHES. PROVIDE 1/4" THICK NEOPRENE GASKETS BETWEEN EQUIPMENT AND ROOF CURBS. 39. ALL EXHAUST FANS SHALL BE CONTROLLED BY TIMECLOCK. 40. COORDINATE ALL CONTROL DEVICES WITH ELECTRICAL CONTRACTOR. 41. ALL CONTROL WIRING, CONDUIT AND HARDWARE TO COMPLETE THE HVAC CONTROL SYSTEM SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 15 - MECHANICAL, 42, ALL CONTROL WIRING AND INTERLOCK WIRING SHALL BE IN CONDUIT. 43. AIR FILTERS SHALL BE 2" PLEATED 30% EFFICIENT (MIN.) OR EQUAL IN AIR HANDLING EQUIPMENT. FILTERS SHALL BE INSTALLED PRIOR TO UNIT START UP, REPLACED A MINIMUM OF ONCE PER MONTH DURING THE CONSTRUCTION PERIOD, REPLACED PRIOR TO TEST AND BALANCE, AND REPLACED MONTHLY UNTIL FINAL COMPLETION. 44. ALL EXHAUST FANS SHALL BE PROVIDED WITH BACK DRAFT DAMPERS. 45. ALL REFRIGERANT LINES FOR SPLIT SYSTEM DX UNITS SHALL HAVE FILTER DRYERS AND SIGHT GLASSES. ALL PIPING BELOW SLAB SHALL BE WITHOUT JOINTS AND RUN IN A PIPING CHASE OR CONDUIT OF SUFFICIENT SIZE TO ALLOW REPLACEMENT IN THE PIPING IN THE FUTURE. EACH END OF THE CHASE SHALT_ BE SEALED AIR TIGHT AND WATERTIGHT. 46. ALL REFRIGERANT PIPING IN CONCEALED CHASES FOR SPLIT DX UNITS SHALL BE SOFT DRAWN TYPE K COPPER. SERVICE FITTINGS FOR REFRIGERANT LINES SHALL BE LOCATED IN A MANNER TO BE INACCESSIBLE TO THE PUBLIC. 47• INTAKE LOUVERS SHALL HAVE 1/2" x 1/2" MINIMUM MESH SCREEN, AND SHALL BE LOCATED Ac 1 11 (11 1 An(1ur nAur'11 r'nAnr Ar nncrr'ln r 52. MULTISTAGE COOLING EQUIPMENT SHALL UTILIZE A SPLIT FACE COOLING COIL OF TWO OR MORE COIL CIRCUITS. THE FIRST STAGE (CIRCUIT) OF COOLING SHALL BE ON THE BOTTOM /� OF THE COIL. DO NOT USE ROW SPLIT OR INTERTWINED COILS. © Copyright 2004 ACi, Inc. HSA HUMAN SERVICES ASSOCIATES, INC. C:: C� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i ASSOCIATED CON'S ULTIING IN'I'ERNATIONAL DEVE•LOPIVIENT.I4L1-iNAGE•iIIENT.ARCHITECTURE FL AA0002940 953 N. PENNSYLVANIA AVE. WINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, disseminaWn, or duplication of any of the information contained herein may result in liability under applicable laws. B ❑ HVAC SYMBOL LEGEND 2412 DUCT -FIRST DIM. IS WIDTH DUCT -SECOND IS HEIGHT-' HP LIMIT OF REMOVAL X DUCT ELBOW DOWN 4 THERMOMETER FLORIDA TATEEBP E. NUMB RM 5131 DUCT ELBOW UP O PRESSURE GAUGE AHU R DUCT RISE --�I f- UNION OR FLANGE D DUCT DOWN INITIAL BALL OR BUTTERFLY VALVE BRAKE HORSEPOWER ® KITCHEN AIR SUPPLY UNIT DUCT UNDER POSITIVE -� f - LAT SA BTU BRITISH THERMAL UNIT PRESSURE LINEAR DIFFUSER CHECK VALVE RA LR LINEAR RETURN DUCT UNDER NEGATIVE CEILING DIFFUSER LVG EA ® OA PRESSURE LVG. WATER TEMPERATURE MODULATING CONTROL VALVE CUBIC FEET PER MINUTE MAU ELBOW W/TURNING VANES TWO POSITION CONTROL VALVE TAKE -OFF W/EXTRACTORS-- CLG PLUG VALVE W/ MEMORY L®� DUCT UP TO UNIT ABOVE FLEXIBLE PIPE CYCLES FLEXIBLE DUCT CONNECTOR NOISE CRITERIA STEAM TRAP CONDENSATE FLEXIBLE DUCT NOT IN CONTRACT STRAINER CONDENSING UNIT SUPPLY AIR TERMINAL NOT TO SCALE DB !® _ ARROW INDICATES THROW OUTSIDE AIR MANUAL RIR VENT ®-+- RETURN OR EXHAUST AIR`- OPERATING AUTOMATIC AIR VENT T ----- -r LINEAR DIFFUSERS -(] 3/4" HOSE END DRAIN PIPE DEGREES FARENHEIT SIDE MOUNTED EHD PUMP, CHEMICAL FEED PRESSURE REDUCING VALVE - BOTTOM MOUNTED EHD RS REFRIGERANT SUCTION IF FIRE DAMPER RL REFRIGERANT LIQUID S SMOKE DAMPER RHG - , REFRIGERANT HOT GAS S/F SMOKE AND FIRE DAMPER CWS - CONDENSER WATER SUPPLY VD VOLUME DAMPER - CWR - CONDENSER WATER RETURN MD MOTORIZED DAMPER -CHWS - CHILLED WATER SUPPLY RVD REMOTE VOLUME DAMPER - CHWR - CHILLED WATER RETURN ELECTRIC HEATER, DUCT SMOKE DETECTOR (DUCT MOUNTED) D CONDENSATE DRAIN L J AD CEILING ACCESS DOOR REVOLUTION PER MINUTE PIPE DOWN ELBOW ® AD DUCT ACCESS DOOR -Q PIPE UP ELBOW QHUMIDITY SENSOR SUPPLY AIR PIPE ELBOW Y ROOM SENSOR :.: PIPE DOWN TEE T THERMOSTAT SPLITTER DAMPER PIPE UP TEE �f SELF CONTAINED THERMOSTAT 0 ROUND EXHAUST FAN POINT OF CONNECTION STATIC PRESSURE ^ EFG EXHAUST FAN, GREASE NEW TO EXIST. WORK SUPPLY AIR REGISTER IT HVAC CENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA MECHANICAL_ CODE WITH 2002 AND 2003 REVISIONS, 2001 FLORIDA ENERGY EFFICIENCY CODE AND THE ORANGE COUNTY BUILDING DEPARTMENT REQUIREMENTS AND ALL OTHER APPLICABLE CODES AND STANDARDS. MECHANICAL ROOMS, LOCATIONS AND SIZES OF BEAMS AND CEILING AND SOFFIT HEIGHTS. 5. DUCTWORK AND EQUIPMENT LOCATIONS AND CLEARANCES SHALL BE COORDINATED WITH GENERAL, PLUMBING AND ELECTRICAL CONTRACTORS. REFER TO ARCHITECTURAL PLANS FOR BUILDING SECTIONS AND DETAILS. 6. CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURERS CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR ALL EQUIPMENT FURNISHED. 7. COORDINATE DIFFUSER, REGISTER AND GRILLE LOCATION WITH LIGHTING, SPRINKLER AND ARCHITECTURAL CEILING PLANS. ALSO COORDINATE THE TYPE OF DIFFUSER FRAME WITH THE CEILING TYPE. 8. ALL HVAC SYSTEMS SHALL BE BALANCED FOR AIR QUANTITIES SHOWN AGAINST THE ACTUAL INSTALLED STATIC PRESSURE OF THE SYSTEM. CONTRACTOR SHALL PROVIDE POSITIVE MEANS FOR BALANCING EACH INDIVIDUAL AIR OUTLET AND INLET. 9. ALL EQUIPMENT SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING VIBRATION ISOLATORS PADS. ALL CONNECTIONS BETWEEN AIR HANDLING EQUIPMENT AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 10. EVERY APPLIANCE AND ALL MECHANICAL EQUIPMENT SHALL BE LOCATED WITH RESPECT TO BUILDING CONSTRUCTION AND OTHER EQUIPMENT SO AS TO PERMIT ACCESS TO THE MECHANICAL EQUIPMENT IN CONFORMITY WITH ANY CLEARANCE WHICH MAY BE RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT. SUFFICIENT CLEARANCE SHALL BE MAINTAINED FOR CLEANING COILS, MOTORS, BURNERS, AS WELL AS CHANGING FILTERS. ALL EQUIPMENT SHALL BE LOCATED WITHIN THE MECHANICAL ROOM AND CEILING SPACES WITH ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE, ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. INSTALLATION OF ALL MECHANICAL EQUIPMENT SHALL COMPLY WITH THE MANUFACTURERS SPECIFICATION AND CLEARANCE REQUIREMENT. 11. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. 12. THE INSIDE OF ALL DUCTS VISIBLE THRU THE FACE OF DIFFUSERS, REGISTERS, AND GRILLES SHALL BE PAINTED FLAT BLACK WITH NON TOXIC PAINT. 13, OUTSIDE AIR AND EXHAUST AIR DUCTWORK SHALL BE GALVANIZED STEEL SHEETS. FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH LATEST EDITION OF SMACNA DUCT CONSTRUCTION STANDARDS FOR A 2 INCH PRESSURE CLASSIFICATION. 14. FLEXIBLE DUCTWORK SHALL BE INSULATED VINYL TYPE (R-6) WITH WIRE SPIRAL SUPPORT. FLEXIBLE DUCTWORK SHALL BE RUN IN MAXIMUM LENGTHS OF 14'-0". FLEXIBLE DUCTWORK SHALL BE PROPERLY SUPPORTED WITH GALVANIZED STEEL_ STRAPS 2" WIDE AND SHALL BE RUN AS STRAIGHT AS POSSIBLE WITH ND KINKS OR BENDS TO RF_STRICT AIRFLOW. 15. ALL SUPPLY AIR AND RETURN AIR DUCTWORK SHALL BE FIBERGLASS DUCTBOARD (R-6). 16. ALL DUCT JOINTS SHALL BE SEALED WITH APPROVED MASTIC. 17. ALL FIBROUS GLASS INSULATION JOINTS, SEAMS AND CONNECTIONS SHALL BE CONSTRUCTED WITH PRESSURE SENSITIVE TAPE, FAB, STAINLESS STEEL STAPLES AND THEN SEALED WITH MASTIC. HEAT AND PRESSURE SENSITIVE TAPE ARE NOT ACCEPTABLE AS A FINAL CLOSURE. 18. PROVIDE HANGER STRAPS FOR ALL DUCTS MADE OF 2" WIDE, 22 GAGE GALVANIZED STEEL - SPACED ACCORDING TO SMACNA STANDARDS AND ALL OTHER APPLICABLE GOVERNING CODES AND STANDARDS. 19. ALL DUCT BRANCH TAKE OFFS FROM MAIN DUCT FOR INDIVIDUAL AIR OUTLETS, INLETS AND BOXES SHALL_ HAVE BALANCING DAMPERS. 20 ALL DUCTWORK STORED ON SITE OR ALREADY INSTALLED SHALT_ HAVE ALL OPEN ENDS SEALED WITH VISQUINE TO PREVENT DUST AND DEBRIS FROM ACCUMULATING INSIDE OF THE DUCTWORK. INTERIORS OF ALL DUCTWORK SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION. 21. ALL DAMPERS AND EXTRACTORS SHALL HAVE LOCKING QUADRANTS AND SHALL BE ACCESSIBLE. 22. PROVIDE REMOTE VOLUME DAMPER OPERATORS IN ALL NON -ACCESSIBLE CEILINGS. EQUAL TO YOUNG REGULATOR COMPANY MODEL 270-896C BOWDEN CABLE CONTROL UNIT. 23. BEVELED TAKE OFFS AND DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTWORK LEADING FROM MAIN TRUNK LINES. 24. ALL SPLITTER DAMPERS SHALL BE BALANCED AND SET PRIOR TO THE INSTALLATION OF THE CEILING. 25. PROVIDE ADJUSTABLE PULLEYS WITH CONSTANT VOLUME AIR HANDLING UNITS AND BELT DRIVE FANS. 26, EXHAUST FAN OUTLETS SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM FRESH AIR INTAKES OF MECHANICAL EQUIPMENT AS WELL AS ALL OPERABLE WINDOWS AND DOORS, 27. ALL FANS AND AIR HANDLING UNITS SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING ISOLATORS. ALL CONNECTIONS BETWEEN FANS OR AIR HANDLING UNITS AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 28. ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACES SHALL HAVE ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE. ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. 29. ALL AIR HANDLING UNITS SHALL BE MOUNTED ON STEEL SKIDS. 30. REFER TO MECHANICAL AND ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE AND SMOKE RATED PARTITIONS. ALL PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS OR FLOORS AND CEILINGS SHALL HAVE FIRE/SMOKE DAMPERS. ALL FIRE WALL PENETRATIONS SHALL HAVE FIRE DAMPERS. PROVIDE ACCESS DOORS IN WALL OR HARD CEILING FOR THESE DAMPERS. 31. PROVIDE ACCESS DOORS (24"x24") FOR ALL FIRE/SMOKE DAMPERS AND FIRE DAMPERS IN NON -ACCESSIBLE CEILINGS, 32. PROVIDE ACCESS PANELS IN DRYWALL CEILINGS AS REQUIRED FOR ACCESS TO MECHANICAL EQUIPMENT. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE WORK PLATFORMS AS REQUIRED FOR ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACE. 33. FURNISH AND INSTALL INSULATED COPPER OR PVC CONDENSATE DRAINS WITH TRAPS FOR ALL ROOFTOP UNIT COOLING COILS. RUN CONDENSATE DRAIN LINE ALONG ROOF TO NEAREST ROOF DRAIN. PROVIDE SUPPORT EVERY 5'-0" O.C. 34. FURNISH AND INSTALL INSULATED PVC CONDENSATE DRAINS WITH TRAPS FOR ALL AIR HANDLING UNIT COOLING COILS. 35. ALL PIPING SHALL BE FULLY SUPPORTED THE ENTIRE LENGTH AND ANCHORED TO PREVENT SWAY AND VIBRATION, 36. DIVISION 16 CONTRACTOR SHALL SUPPLY AND WIRE ALL SMOKE DETECTORS IN THE SUPPLY AIR DUCTWORK OF ALL AIR HANDLING UNITS 2000 CFM AND ABOVE TO SHUT DOWN THE FANS IN THE EVENT OF A FIRE. DUCT SMOKE DETECTOR SHALL BE OF PHOTOELECTRIC TYPE AND LOW VOLTAGE. DIVISION 15 CONTRACTOR SHALL INSTALL ALL SMOKE DETECTORS, 37. ALL WALL SENSORS, VARIABLE SPEED CONTROL SWITCHES, ON-OFF SWITCHES AND MOTOR STARTERS SHALL BE INDIVIDUALLY LABELED. LABELS SHALL INDICATED THE UNIT CONTROLLED, TYPE OF CONTROL AND AREA SERVED. THE LABELS SHALL BE PLASTIC LAMINATE, PERMANENT TYPE, WHITE WITH BLACK LETTERING, AND SHALL BE MOUNTED INSIDE OF THE COVER PLATE, OF THE CONTROL DEVICE. 38, ALL ROOF MOUNTED FANS AND PACKAGE A/C UNITS SHALL BE BOLTED DOWN TO ROOF CURB USING 1/4" STAINLESS STEEL BOLTS EVERY 12" INCHES. PROVIDE 1/4" THICK NEOPRENE GASKETS BETWEEN EQUIPMENT AND ROOF CURBS. 39. ALL EXHAUST FANS SHALL BE CONTROLLED BY TIMECLOCK. 40. COORDINATE ALL CONTROL DEVICES WITH ELECTRICAL CONTRACTOR. 41. ALL CONTROL WIRING, CONDUIT AND HARDWARE TO COMPLETE THE HVAC CONTROL SYSTEM SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 15 - MECHANICAL, 42, ALL CONTROL WIRING AND INTERLOCK WIRING SHALL BE IN CONDUIT. 43. AIR FILTERS SHALL BE 2" PLEATED 30% EFFICIENT (MIN.) OR EQUAL IN AIR HANDLING EQUIPMENT. FILTERS SHALL BE INSTALLED PRIOR TO UNIT START UP, REPLACED A MINIMUM OF ONCE PER MONTH DURING THE CONSTRUCTION PERIOD, REPLACED PRIOR TO TEST AND BALANCE, AND REPLACED MONTHLY UNTIL FINAL COMPLETION. 44. ALL EXHAUST FANS SHALL BE PROVIDED WITH BACK DRAFT DAMPERS. 45. ALL REFRIGERANT LINES FOR SPLIT SYSTEM DX UNITS SHALL HAVE FILTER DRYERS AND SIGHT GLASSES. ALL PIPING BELOW SLAB SHALL BE WITHOUT JOINTS AND RUN IN A PIPING CHASE OR CONDUIT OF SUFFICIENT SIZE TO ALLOW REPLACEMENT IN THE PIPING IN THE FUTURE. EACH END OF THE CHASE SHALT_ BE SEALED AIR TIGHT AND WATERTIGHT. 46. ALL REFRIGERANT PIPING IN CONCEALED CHASES FOR SPLIT DX UNITS SHALL BE SOFT DRAWN TYPE K COPPER. SERVICE FITTINGS FOR REFRIGERANT LINES SHALL BE LOCATED IN A MANNER TO BE INACCESSIBLE TO THE PUBLIC. 47• INTAKE LOUVERS SHALL HAVE 1/2" x 1/2" MINIMUM MESH SCREEN, AND SHALL BE LOCATED Ac 1 11 (11 1 An(1ur nAur'11 r'nAnr Ar nncrr'ln r 52. MULTISTAGE COOLING EQUIPMENT SHALL UTILIZE A SPLIT FACE COOLING COIL OF TWO OR MORE COIL CIRCUITS. THE FIRST STAGE (CIRCUIT) OF COOLING SHALL BE ON THE BOTTOM /� OF THE COIL. DO NOT USE ROW SPLIT OR INTERTWINED COILS. © Copyright 2004 ACi, Inc. HSA HUMAN SERVICES ASSOCIATES, INC. C:: C� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i ASSOCIATED CON'S ULTIING IN'I'ERNATIONAL DEVE•LOPIVIENT.I4L1-iNAGE•iIIENT.ARCHITECTURE FL AA0002940 953 N. PENNSYLVANIA AVE. WINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, disseminaWn, or duplication of any of the information contained herein may result in liability under applicable laws. B ❑ A AC AIR CONDITIONING HP HORESPOWER AFF ABOVE FINISHED FLOOR HVAC HEATING, VENTILATING & FLORIDA TATEEBP E. NUMB RM 5131 AIR CONDITIONING AHU AIR HANDLING UNIT H2O WATER BDD BACKDRAFT DAMPER INR INITIAL BHP BRAKE HORSEPOWER KSU KITCHEN AIR SUPPLY UNIT BMS BUILDING MANAGEMENT SYSTEM LAT LVG. AIR TEMPERATURE BTU BRITISH THERMAL UNIT LD LINEAR DIFFUSER CC COOLING COIL LR LINEAR RETURN CD CEILING DIFFUSER LVG LEAVING CF CHEMICAL FEEDER LWT LVG. WATER TEMPERATURE CFM CUBIC FEET PER MINUTE MAU MAKE UP AIR UNITKITCHEN HOOD CLG CEILING MBH MEGA BTU PER HOUR CYC CYCLES NC NOISE CRITERIA COND CONDENSATE NIC NOT IN CONTRACT CU CONDENSING UNIT NTS NOT TO SCALE DB DRY BULB OA OUTSIDE AIR DIM DIMENSION OPER OPERATING F FILTER OV OUTLET VELOCITY 'F DEGREES FARENHEIT PCF PUMP, CHEMICAL FEED DWG DRAWING PCH PUMP, CHILLED WATER EA EXHAUST AIR PO PRESSURE DROP EAT ENT. AIR TEMPERATURE PH PHASE EF EXHAUST FAN RA RETURN AIR EG EXHAUST AIR GRILLE RF RETURN FAN ENC ELECTRIC HEATING COIL RG RETURN AIR GRILLE EHD ELECTRIC HEATER, DUCT ROT ROTATION EHU ELECTRIC UNIT HEATER RPM REVOLUTION PER MINUTE EHW ELECTRIC HEATER, WALL RTU ROOF TOP UNIT ENT ENTERING SA SUPPLY AIR ER EXHAUST AIR REGISTER SENS SENSIBLE EWT ENT. WATER TEMPERATURE SD SPLITTER DAMPER FCU FAN COIL UNIT SF SUPPLY FAN EF EXHAUST FAN SP STATIC PRESSURE ^ EFG EXHAUST FAN, GREASE SR SUPPLY AIR REGISTER IT FLY FAN TG TRANSFER AIR GRILLE FPI FINS PER INCH TEMP TEMPERATURE FPM FEET PER MINUTE UD UNDERCUT DOOR FR FAN, RETURN VG VENT, GRAVITY GPM GALLONS PER MINUTE W WATTS HD HUB DRAIN WB WET BULB HOA HAND/OFF/AUTOMATIC W/ WITH HVAC CENERAL NOTES 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE 2001 FLORIDA MECHANICAL_ CODE WITH 2002 AND 2003 REVISIONS, 2001 FLORIDA ENERGY EFFICIENCY CODE AND THE ORANGE COUNTY BUILDING DEPARTMENT REQUIREMENTS AND ALL OTHER APPLICABLE CODES AND STANDARDS. MECHANICAL ROOMS, LOCATIONS AND SIZES OF BEAMS AND CEILING AND SOFFIT HEIGHTS. 5. DUCTWORK AND EQUIPMENT LOCATIONS AND CLEARANCES SHALL BE COORDINATED WITH GENERAL, PLUMBING AND ELECTRICAL CONTRACTORS. REFER TO ARCHITECTURAL PLANS FOR BUILDING SECTIONS AND DETAILS. 6. CONNECTION TO ALL EQUIPMENT SHALL BE VERIFIED WITH MANUFACTURERS CERTIFIED DRAWINGS. TRANSITIONS TO ALL EQUIPMENT SHALL BE VERIFIED AND PROVIDED FOR ALL EQUIPMENT FURNISHED. 7. COORDINATE DIFFUSER, REGISTER AND GRILLE LOCATION WITH LIGHTING, SPRINKLER AND ARCHITECTURAL CEILING PLANS. ALSO COORDINATE THE TYPE OF DIFFUSER FRAME WITH THE CEILING TYPE. 8. ALL HVAC SYSTEMS SHALL BE BALANCED FOR AIR QUANTITIES SHOWN AGAINST THE ACTUAL INSTALLED STATIC PRESSURE OF THE SYSTEM. CONTRACTOR SHALL PROVIDE POSITIVE MEANS FOR BALANCING EACH INDIVIDUAL AIR OUTLET AND INLET. 9. ALL EQUIPMENT SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING VIBRATION ISOLATORS PADS. ALL CONNECTIONS BETWEEN AIR HANDLING EQUIPMENT AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 10. EVERY APPLIANCE AND ALL MECHANICAL EQUIPMENT SHALL BE LOCATED WITH RESPECT TO BUILDING CONSTRUCTION AND OTHER EQUIPMENT SO AS TO PERMIT ACCESS TO THE MECHANICAL EQUIPMENT IN CONFORMITY WITH ANY CLEARANCE WHICH MAY BE RECOMMENDED BY THE MANUFACTURER OF THE EQUIPMENT. SUFFICIENT CLEARANCE SHALL BE MAINTAINED FOR CLEANING COILS, MOTORS, BURNERS, AS WELL AS CHANGING FILTERS. ALL EQUIPMENT SHALL BE LOCATED WITHIN THE MECHANICAL ROOM AND CEILING SPACES WITH ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE, ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. INSTALLATION OF ALL MECHANICAL EQUIPMENT SHALL COMPLY WITH THE MANUFACTURERS SPECIFICATION AND CLEARANCE REQUIREMENT. 11. ALL DUCT DIMENSIONS SHOWN ARE CLEAR INSIDE DIMENSIONS. 12. THE INSIDE OF ALL DUCTS VISIBLE THRU THE FACE OF DIFFUSERS, REGISTERS, AND GRILLES SHALL BE PAINTED FLAT BLACK WITH NON TOXIC PAINT. 13, OUTSIDE AIR AND EXHAUST AIR DUCTWORK SHALL BE GALVANIZED STEEL SHEETS. FABRICATION AND INSTALLATION SHALL BE IN ACCORDANCE WITH LATEST EDITION OF SMACNA DUCT CONSTRUCTION STANDARDS FOR A 2 INCH PRESSURE CLASSIFICATION. 14. FLEXIBLE DUCTWORK SHALL BE INSULATED VINYL TYPE (R-6) WITH WIRE SPIRAL SUPPORT. FLEXIBLE DUCTWORK SHALL BE RUN IN MAXIMUM LENGTHS OF 14'-0". FLEXIBLE DUCTWORK SHALL BE PROPERLY SUPPORTED WITH GALVANIZED STEEL_ STRAPS 2" WIDE AND SHALL BE RUN AS STRAIGHT AS POSSIBLE WITH ND KINKS OR BENDS TO RF_STRICT AIRFLOW. 15. ALL SUPPLY AIR AND RETURN AIR DUCTWORK SHALL BE FIBERGLASS DUCTBOARD (R-6). 16. ALL DUCT JOINTS SHALL BE SEALED WITH APPROVED MASTIC. 17. ALL FIBROUS GLASS INSULATION JOINTS, SEAMS AND CONNECTIONS SHALL BE CONSTRUCTED WITH PRESSURE SENSITIVE TAPE, FAB, STAINLESS STEEL STAPLES AND THEN SEALED WITH MASTIC. HEAT AND PRESSURE SENSITIVE TAPE ARE NOT ACCEPTABLE AS A FINAL CLOSURE. 18. PROVIDE HANGER STRAPS FOR ALL DUCTS MADE OF 2" WIDE, 22 GAGE GALVANIZED STEEL - SPACED ACCORDING TO SMACNA STANDARDS AND ALL OTHER APPLICABLE GOVERNING CODES AND STANDARDS. 19. ALL DUCT BRANCH TAKE OFFS FROM MAIN DUCT FOR INDIVIDUAL AIR OUTLETS, INLETS AND BOXES SHALL_ HAVE BALANCING DAMPERS. 20 ALL DUCTWORK STORED ON SITE OR ALREADY INSTALLED SHALT_ HAVE ALL OPEN ENDS SEALED WITH VISQUINE TO PREVENT DUST AND DEBRIS FROM ACCUMULATING INSIDE OF THE DUCTWORK. INTERIORS OF ALL DUCTWORK SHALL BE THOROUGHLY CLEANED PRIOR TO INSTALLATION. 21. ALL DAMPERS AND EXTRACTORS SHALL HAVE LOCKING QUADRANTS AND SHALL BE ACCESSIBLE. 22. PROVIDE REMOTE VOLUME DAMPER OPERATORS IN ALL NON -ACCESSIBLE CEILINGS. EQUAL TO YOUNG REGULATOR COMPANY MODEL 270-896C BOWDEN CABLE CONTROL UNIT. 23. BEVELED TAKE OFFS AND DAMPERS SHALL BE INSTALLED IN ALL BRANCH DUCTWORK LEADING FROM MAIN TRUNK LINES. 24. ALL SPLITTER DAMPERS SHALL BE BALANCED AND SET PRIOR TO THE INSTALLATION OF THE CEILING. 25. PROVIDE ADJUSTABLE PULLEYS WITH CONSTANT VOLUME AIR HANDLING UNITS AND BELT DRIVE FANS. 26, EXHAUST FAN OUTLETS SHALL BE INSTALLED A MINIMUM OF 10'-0" FROM FRESH AIR INTAKES OF MECHANICAL EQUIPMENT AS WELL AS ALL OPERABLE WINDOWS AND DOORS, 27. ALL FANS AND AIR HANDLING UNITS SHALL BE PROPERLY SUPPORTED AND ISOLATED TO PREVENT NOISE AND VIBRATION TRANSMISSION. ALL AIR HANDLING EQUIPMENT SHALL BE SUPPORTED OR SUSPENDED WITH SPRING ISOLATORS. ALL CONNECTIONS BETWEEN FANS OR AIR HANDLING UNITS AND DUCTWORK SHALL BE CANVAS FLEXIBLE CONNECTORS. 28. ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACES SHALL HAVE ADEQUATE CLEARANCES FOR REPAIR AND MAINTENANCE. ALL PIPING AND DUCTWORK SHALL BE INSTALLED TO PROVIDE ADEQUATE CLEARANCE FOR ACCESS TO ALL EQUIPMENT. 29. ALL AIR HANDLING UNITS SHALL BE MOUNTED ON STEEL SKIDS. 30. REFER TO MECHANICAL AND ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE AND SMOKE RATED PARTITIONS. ALL PENETRATIONS THROUGH FIRE RATED/SMOKE RATED PARTITIONS OR FLOORS AND CEILINGS SHALL HAVE FIRE/SMOKE DAMPERS. ALL FIRE WALL PENETRATIONS SHALL HAVE FIRE DAMPERS. PROVIDE ACCESS DOORS IN WALL OR HARD CEILING FOR THESE DAMPERS. 31. PROVIDE ACCESS DOORS (24"x24") FOR ALL FIRE/SMOKE DAMPERS AND FIRE DAMPERS IN NON -ACCESSIBLE CEILINGS, 32. PROVIDE ACCESS PANELS IN DRYWALL CEILINGS AS REQUIRED FOR ACCESS TO MECHANICAL EQUIPMENT. COORDINATE WITH GENERAL CONTRACTOR TO PROVIDE WORK PLATFORMS AS REQUIRED FOR ALL EQUIPMENT LOCATED WITHIN THE CEILING SPACE. 33. FURNISH AND INSTALL INSULATED COPPER OR PVC CONDENSATE DRAINS WITH TRAPS FOR ALL ROOFTOP UNIT COOLING COILS. RUN CONDENSATE DRAIN LINE ALONG ROOF TO NEAREST ROOF DRAIN. PROVIDE SUPPORT EVERY 5'-0" O.C. 34. FURNISH AND INSTALL INSULATED PVC CONDENSATE DRAINS WITH TRAPS FOR ALL AIR HANDLING UNIT COOLING COILS. 35. ALL PIPING SHALL BE FULLY SUPPORTED THE ENTIRE LENGTH AND ANCHORED TO PREVENT SWAY AND VIBRATION, 36. DIVISION 16 CONTRACTOR SHALL SUPPLY AND WIRE ALL SMOKE DETECTORS IN THE SUPPLY AIR DUCTWORK OF ALL AIR HANDLING UNITS 2000 CFM AND ABOVE TO SHUT DOWN THE FANS IN THE EVENT OF A FIRE. DUCT SMOKE DETECTOR SHALL BE OF PHOTOELECTRIC TYPE AND LOW VOLTAGE. DIVISION 15 CONTRACTOR SHALL INSTALL ALL SMOKE DETECTORS, 37. ALL WALL SENSORS, VARIABLE SPEED CONTROL SWITCHES, ON-OFF SWITCHES AND MOTOR STARTERS SHALL BE INDIVIDUALLY LABELED. LABELS SHALL INDICATED THE UNIT CONTROLLED, TYPE OF CONTROL AND AREA SERVED. THE LABELS SHALL BE PLASTIC LAMINATE, PERMANENT TYPE, WHITE WITH BLACK LETTERING, AND SHALL BE MOUNTED INSIDE OF THE COVER PLATE, OF THE CONTROL DEVICE. 38, ALL ROOF MOUNTED FANS AND PACKAGE A/C UNITS SHALL BE BOLTED DOWN TO ROOF CURB USING 1/4" STAINLESS STEEL BOLTS EVERY 12" INCHES. PROVIDE 1/4" THICK NEOPRENE GASKETS BETWEEN EQUIPMENT AND ROOF CURBS. 39. ALL EXHAUST FANS SHALL BE CONTROLLED BY TIMECLOCK. 40. COORDINATE ALL CONTROL DEVICES WITH ELECTRICAL CONTRACTOR. 41. ALL CONTROL WIRING, CONDUIT AND HARDWARE TO COMPLETE THE HVAC CONTROL SYSTEM SHALL BE FURNISHED AND INSTALLED UNDER DIVISION 15 - MECHANICAL, 42, ALL CONTROL WIRING AND INTERLOCK WIRING SHALL BE IN CONDUIT. 43. AIR FILTERS SHALL BE 2" PLEATED 30% EFFICIENT (MIN.) OR EQUAL IN AIR HANDLING EQUIPMENT. FILTERS SHALL BE INSTALLED PRIOR TO UNIT START UP, REPLACED A MINIMUM OF ONCE PER MONTH DURING THE CONSTRUCTION PERIOD, REPLACED PRIOR TO TEST AND BALANCE, AND REPLACED MONTHLY UNTIL FINAL COMPLETION. 44. ALL EXHAUST FANS SHALL BE PROVIDED WITH BACK DRAFT DAMPERS. 45. ALL REFRIGERANT LINES FOR SPLIT SYSTEM DX UNITS SHALL HAVE FILTER DRYERS AND SIGHT GLASSES. ALL PIPING BELOW SLAB SHALL BE WITHOUT JOINTS AND RUN IN A PIPING CHASE OR CONDUIT OF SUFFICIENT SIZE TO ALLOW REPLACEMENT IN THE PIPING IN THE FUTURE. EACH END OF THE CHASE SHALT_ BE SEALED AIR TIGHT AND WATERTIGHT. 46. ALL REFRIGERANT PIPING IN CONCEALED CHASES FOR SPLIT DX UNITS SHALL BE SOFT DRAWN TYPE K COPPER. SERVICE FITTINGS FOR REFRIGERANT LINES SHALL BE LOCATED IN A MANNER TO BE INACCESSIBLE TO THE PUBLIC. 47• INTAKE LOUVERS SHALL HAVE 1/2" x 1/2" MINIMUM MESH SCREEN, AND SHALL BE LOCATED Ac 1 11 (11 1 An(1ur nAur'11 r'nAnr Ar nncrr'ln r 52. MULTISTAGE COOLING EQUIPMENT SHALL UTILIZE A SPLIT FACE COOLING COIL OF TWO OR MORE COIL CIRCUITS. THE FIRST STAGE (CIRCUIT) OF COOLING SHALL BE ON THE BOTTOM /� OF THE COIL. DO NOT USE ROW SPLIT OR INTERTWINED COILS. © Copyright 2004 ACi, Inc. HSA HUMAN SERVICES ASSOCIATES, INC. C:: C� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i ASSOCIATED CON'S ULTIING IN'I'ERNATIONAL DEVE•LOPIVIENT.I4L1-iNAGE•iIIENT.ARCHITECTURE FL AA0002940 953 N. PENNSYLVANIA AVE. WINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, disseminaWn, or duplication of any of the information contained herein may result in liability under applicable laws. B ❑ A BORES ASSOCIATES CONSULTING ENGINEERS Issue/Revision By 1 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628.7024 VE / REVISION ABJr FLORIDA TATEEBP E. NUMB RM 5131 Issues and Revisions No. Date Issue/Revision By 1 02/23/05 VE / REVISION ABJr Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416.dNvg Phase: PERMIT DOCUMENT Sheet Name: LEGEND & NOTES - HVAC SHEET NUMBER M 001 1( 0 0 10 to It N 00n CtiL W x 0 N 0 z D 7 It N 1 D P :,L VO CD -2, 100 CFM 14 16x6 CONDENSATE DRYVWELL ___ -- I I G-3, I - I I 1 I► f-_ - r 0-4 n _ -� -I .1- - _ 200 CFM 6 % CD -1, I# 11 1 1 100 CFM 2 6 0 D-1, 8"� CD -1, I I I ' l I 6x6 100 CFM 150 CFMC 200 CFM --- - -- - - - -- - --_...........- - - - - - --- - -- --- -- --r - zr- T (� `...... s = --- rte- # # 1 i '._._.�. _ l r_ _ I - _- sC # # 7 f_j - - ..,nT'i� 1. - - # Ii _'..�€ -- tom- �='---- ---- _`----- I i ,\-., I I r# °. i €;- r.,.- 1 I : H I I' 1 "...t-_=7� #!!.. #€ i �.> �' - .� _ - - _ . Y _- _ - - _ - _ _ - �- _! I ;T > I , ; l } 1 3 _„ _3i�_a# i ; , - Jc:� _i F �I i , _ r } r I (. I {j; _ - V_ _- I # , _ i I _ ---� - I 1 £ _ I , - _ _ - I _ - - - 1 - _ F. r- 1 4"O CD -2 # - A�t_1 - 28 I € # 1 I �1 , i EF 3 50 CFM I i UC i€ 1 1 1 _ �j 1 t 1 _ I sj _ i II , 11 I I x12. �..._ -:. I I I ,## I sy I ll 1' f. 1 _ 1 y I I Ifi�_ -- -- -_ ��---I GL- : � _ _ - 1 I - _- - _ _ - - --- _ , € - - - #€ i= UC UC UC } LIC ,�_ _ 7 10x10 G=7 6 0 CD 2, I 0 UC 8x8 r I VD 100 CFM 0 Q G_3 ,-�- Wf 1,.- j1 2 - _ _ I :. -- - - t 0IJ CFM 1 - -- - " --- _ - - --, -= ---..-..-_... _, --- _- _ - fi 1, _, , I I r r, - 12 I I II 11° i 13 I• _" _ ; -F"3 - [ #�.,s� g r" `r., _ I 3- I 6 CD -1, I i1 = ' 1 - _;= 'X71 11, `_ i = I I 1 t=rte' , 1 !' O _ .. , s,�D }0 s ,. , I:1r _ I�_1r _� 100 CFM - - :, _ I - , 10x10 I wy f,'�� T I L; j -�-� �r I I I _ 8x8 :#. 11 °_ I. '° 'v I ,I Pte- i i I I 1 _ - I _ -- - _ - - _ - -- - - - --_ __- - - _ , 1° r - 1i _ f-- _ __s .I-lv _ EF -4 14x12 - I II r X11 ` , ,I = , i1 <__ 11 1 __ I �� - , I 1 r €,--� r f r - 3'I 1 - 1 E i I a I I �� _.� 1 I -- ; ,1 i I ,1,iD Z I ri J f ,Ir Mo r m - ,1 _ 1 (5) WR -2, 1 = r F' "(jI 1 _ ).i I f f1 ' - ,44 ,�r ,t , f i1 - 1 -- I I= , _ I 1�� IUC I - � 1 29 1 , , / I :I 180 CFM I I: ;1=1 _ - ° y .._ € II = I 7, 2/1 ice'€ i�� �I ' thAlS �I : ,. '�mT I - srAU r = Ii €I r " I' _ I# I i, , # i 11I 1r- - Fi4 - -= _ - - VD - j T } } } - 25C v = _ - - - -r - - ,-i - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - II I - t € - . 6 CD -1, 24x20 10�..# �-'`-- - - 6x10r .-- t ;I l -"'D _I 4 - = ---- x L0 I VD 10 ' fir -i, 12 6 U P - 100 CFM :I 1 I I ` I I = G -ill i 1 -- - _ !I _ li X IIA3 SSE - _-,1 i . _ _ _ i _ _ - I =< VD rte, I'r11, =t: O . - __- z - L 1 -i 0 . = I I = '� ase; - . _i3x10 , r I I � 45' DOWN STANDARD DUCT CONSTRUCTION, SEAMS WATER TIGHT ANGLE RIVETED OR SPOT WELDED AS REQUIRED PROVIDE 1/2" DIAMETER STAINLESS STEEL BOLT TYPICAL OF 4 - 1 PER SIDE. INSTALLATION SHALL MEET WIND LOADS PER 2001 FLORIDA BUILDING CODE BIRD SCREEN SPECIFIED DUCT FLASHING -BOLT AND SIZE SEAL TO DUCTWORK DUCT SIZE +25% WATER TIGHT _ _ — _ 18" MINIMUM ROOF CURB i- ROOFING G00""SENECK DETAIL NOT TO SCALE f- BRANCH DUCT MANUAL DAMPER WITH f QUADRANT LOCKING LEVER EXPOSED DAMPER HANDLE ON OUTSIDE OF INSULATION AND PAINTED BRIGHT YELLOW L _AV_ AIR FLOW i �L SUPPLY AIR DUCT WITH FLEXIBLE CONNECTOR Ain I IA AIMI — —k I—If ATr ITH tEW T LINE A i/4" -HANDLING" O E W rL `- BRANCH DUCT L=1/4W,(4"MIN) MANUAL DAMPER WITH QUADRANT LOCKING LEVER — ON OUTSIDE OF INSULATION L HEIGHT AS REQUIR FOR R.A. DUCT (MINIMUM 16") /' 11 A , " /" 4x 1 /8< x GRED ANGLE IRON. RUST INHIBITING I TO MATCH AHU HEIGHT AS REQUIRED TO ACCOMMODATE RETURN AIR DUCTWORK SLOPE CONCRETE COVER SLOPE n U. SUPPORT BASE NOT TO SCALE ALTERNATE LOCATION DOWNSTREAM FULL RADIUS OR MITERED OF ELBOW OR OBSTRUCTION ELBOW W/ TRAILING EDGE TURNING VANES AIR FLOW {- A -{ 18" MINIMUM STRAIGHT W DUCT DOWNSTREAM 18" MINIMUM ELECTRIC HEATING COIL STRAIGHT DUCT — PREFERRED LOCATION UPSTREAM DOWNSTREAM OF ELBOW OR OBSTRUCTION A MINIMUM STRAIGHT DUCT UPSTREAM A= 2 X W OR 4 FT WHICHEVER IS GREATER (A =MINIMUM TO OBSTRUCTION, FITTING, OR DUCT TRANSITION) ELECTRICL NOT TO SCALE 3/16"x2" WIDE GALVANIZED STEEL HOLD DOWN STRAP BOLTED TO ROOF CURB WITH 3/16 STAINLESS STEEL BOLTS AND WELDED OR BOLTED TO ROOF SUPPORT STRUCTURE BELOW. PROVIDE ONE STRAP PER SIDE OF CURB. PROVIDE OPENINGS THROUGH ROOF DECK AS REQUIRED FOR ATTACHMENT OF STRAPS TO ROOF STRUCTURE. _____—MITERED CORNERS ON TOP PROVIDE OPENINGS IN ROOF AS REQUIRED TO RUN SUPPLY AND RETURN DUCTWORK THROUGH ROOF. OPENINGS SHALL BE 2" LARGER THAN DUCT PENETRATIONS AND SHALL ALIGN WITH SUPPLY AND RETURN OPENINGS OF ROOF TOP UNIT. 14" MIN INSULATED BASE PANS W/ GASKET NOTES: 1. REFER TO MANUFACTURERS CERTIFIED DRAWINGS FOR DIMENSIONS. 2. ROOF CURB SHALL BE INSTALLED PER MANUFACTURERS DATA. 3, ALL CURBS SHALL BE INSULATED DOUBLE WALL. 4. FOR FLASHING SEE ARCHITECTURAL DRAWINGS. 5. CONSTRUCTION SHALL BE GALVANIZED STEEL WITH STAINLESS STEEL BOLTS/NUTS. ROOF MOUNTING CURB DETAIL ATTACH ROOF CURB TO ROOF DECK WITH 1/2" DIAMETER STAINLESS STEEL TIE DOWN BOLTS (LENGTH AS REQUIRED TYPICAL OF 8 - 2 PER SIDE). INSTALLATION SHALL MEET WIND LOADS FOR FLORIDA BUILDING CODE VWit, ` \ o 0 SIZE AS INDICATED FLEX CONN. AND SPECIFICATIONS ALUMINUM 30' FACE LINING ON DRAWING - � BEARING OPTION File Name: _2010416.dNvg ` � ` —I WING NUT ���� ROD CONTINUOUS j l J�AIR VALVE ON ALL DAMPERS ARM 3D OVER 12" DIA. ELEVATION DUCT ROUND DAMPER 2 -BLADE ARRANGEMENT — RETURN VD, LOCATE AS FAR DUCT 1/8" CLEARANCE — _I AWAY FROM GRILLE ALL AROUND X- DUCT 3/8 3/8 PIN QUADRANT SIZE 1/2" �\ 1/2" ROD -PIN SIZE AS INDICATED ' QUADRANT 1/8" CLEARANCE 22 GA. BLADE ' ALL AROUND 16 GA. BLADE UP TO 18" - 19" TO 48" = ~ STIFFEN AS REQUIRED 1/2" NOTE: OVER 12" HIGH USE MULTIPLE BLADES. 0 I SIDE ELEVATION i �L SUPPLY AIR DUCT WITH FLEXIBLE CONNECTOR Ain I IA AIMI — —k I—If ATr ITH tEW T LINE A i/4" -HANDLING" O E W rL `- BRANCH DUCT L=1/4W,(4"MIN) MANUAL DAMPER WITH QUADRANT LOCKING LEVER — ON OUTSIDE OF INSULATION L HEIGHT AS REQUIR FOR R.A. DUCT (MINIMUM 16") /' 11 A , " /" 4x 1 /8< x GRED ANGLE IRON. RUST INHIBITING I TO MATCH AHU HEIGHT AS REQUIRED TO ACCOMMODATE RETURN AIR DUCTWORK SLOPE CONCRETE COVER SLOPE n U. SUPPORT BASE NOT TO SCALE ALTERNATE LOCATION DOWNSTREAM FULL RADIUS OR MITERED OF ELBOW OR OBSTRUCTION ELBOW W/ TRAILING EDGE TURNING VANES AIR FLOW {- A -{ 18" MINIMUM STRAIGHT W DUCT DOWNSTREAM 18" MINIMUM ELECTRIC HEATING COIL STRAIGHT DUCT — PREFERRED LOCATION UPSTREAM DOWNSTREAM OF ELBOW OR OBSTRUCTION A MINIMUM STRAIGHT DUCT UPSTREAM A= 2 X W OR 4 FT WHICHEVER IS GREATER (A =MINIMUM TO OBSTRUCTION, FITTING, OR DUCT TRANSITION) ELECTRICL NOT TO SCALE 3/16"x2" WIDE GALVANIZED STEEL HOLD DOWN STRAP BOLTED TO ROOF CURB WITH 3/16 STAINLESS STEEL BOLTS AND WELDED OR BOLTED TO ROOF SUPPORT STRUCTURE BELOW. PROVIDE ONE STRAP PER SIDE OF CURB. PROVIDE OPENINGS THROUGH ROOF DECK AS REQUIRED FOR ATTACHMENT OF STRAPS TO ROOF STRUCTURE. _____—MITERED CORNERS ON TOP PROVIDE OPENINGS IN ROOF AS REQUIRED TO RUN SUPPLY AND RETURN DUCTWORK THROUGH ROOF. OPENINGS SHALL BE 2" LARGER THAN DUCT PENETRATIONS AND SHALL ALIGN WITH SUPPLY AND RETURN OPENINGS OF ROOF TOP UNIT. 14" MIN INSULATED BASE PANS W/ GASKET NOTES: 1. REFER TO MANUFACTURERS CERTIFIED DRAWINGS FOR DIMENSIONS. 2. ROOF CURB SHALL BE INSTALLED PER MANUFACTURERS DATA. 3, ALL CURBS SHALL BE INSULATED DOUBLE WALL. 4. FOR FLASHING SEE ARCHITECTURAL DRAWINGS. 5. CONSTRUCTION SHALL BE GALVANIZED STEEL WITH STAINLESS STEEL BOLTS/NUTS. ROOF MOUNTING CURB DETAIL ATTACH ROOF CURB TO ROOF DECK WITH 1/2" DIAMETER STAINLESS STEEL TIE DOWN BOLTS (LENGTH AS REQUIRED TYPICAL OF 8 - 2 PER SIDE). INSTALLATION SHALL MEET WIND LOADS FOR FLORIDA BUILDING CODE VWit, RETURN A GRILLE WI" PLENUM PLE VD, LOCATE AS FAR AWAY FROM GRILLE AS POSSIBLE STRAP SUPPORT----�,, (5'f O.C. MAX.) MYLAR REINFORCED FACTORY ELECTRIC DISCONNECT INTEGRAL W/ UNIT CONTINUOUS ROOF DECK-\ PRE -MANUFACTURED ROOF CURB FOR FLASHING SEE ARCHITECTURAL DRAWING ROOFING MATERIAL -' FOR ROOF, SEE ARCHITECTURAL DRAWING FILL CAVITY W/ FIBER GLASS INSULATION CONTROL BOX 2" STRAP OR DRAW BAND INSULATED (1" THICK) FLEXIBLE DUCT FOR SIZE AS NOTED ON PLANS. MAXIMUM LENGTH IS 10'-0" CAULK & SEAL AT BOTH DIFFUSER NECK AND FLEXIBLE DUCT CONNECTION. TIGHTEN WITH DRAW BAND. INSULATE TOP OF DIFFUSER f WITH 2" THICK FIBERGLASS BLANKET INSULATION. EXPOSED CEILING TEE REGULAR CEILING PANEL DIFFUSER CONNECYRD"N DETAIL NOT TO SCALE SMOKE DETECTOR INSIDE OF ROOFTOP UNIT MOTORIZED OUTSIDE PROVIDE ACCESS DOOR AIR DAMPER 0/A INTAKE �i i FJ HOOD I I 0 ROOFTOP AIR HANDLER 3/16" THICK GALVANIZED TIE DOWN OF S I RTU TO ROOF CURB WITH 1/2" DIAMETER STAINLESS STEEL BOLTS (TYPICAL OF 8 - 2 PER CORNER) INSTALLATION SHALL MEET WIND LOADS SUPPLY RETURN FOR FLORIDA BUILDING CODE AIR AIR ROOF JOIST (TYPICAL) NOTE: SEE ARCHITECTURAL 1. COORDINATE ROOF OPENINGS WITH STRUCTURAL. DRAWING KEEP OPENING TO MINIMUM AS REQUIRED, ALSO COORDINATE OPENINGS WITH BAR JOIST OR ROOF TRUSS LOCATION. E FLEX DUCT AS PER PLANS SIZE AS INDICATED FLEX CONN. AND SPECIFICATIONS ALUMINUM 30' FACE LINING ON DRAWING _--� FVICE: LORIDA P EESENG.COM 5638.7024 File Name: _2010416.dNvg ` , t ` —I Sheet Name: 0 j l J�AIR VALVE RETURN AIR 24° 3D GRILLE WITH PLENUM PLENUM — RETURN VD, LOCATE AS FAR — _I AWAY FROM GRILLE AS POSSIBLE T.A. FILTER SIZE SIZE AS INDICATED AS INDICATED ON DRAWING ON DRAWING _ _- __ - 24 RETURN TO AHU SIZE AS INDICATED ON DRAWING NYLON TY -WRAP TIGHTENED WITH TY -WRAP TOOL OR S.S. DRAW BAND T.A. FILTER - /,,--ALUMINUM ' R=D ALUMINUM i-30' I inuklr- RETURN A GRILLE WI" PLENUM PLE VD, LOCATE AS FAR AWAY FROM GRILLE AS POSSIBLE STRAP SUPPORT----�,, (5'f O.C. MAX.) MYLAR REINFORCED FACTORY ELECTRIC DISCONNECT INTEGRAL W/ UNIT CONTINUOUS ROOF DECK-\ PRE -MANUFACTURED ROOF CURB FOR FLASHING SEE ARCHITECTURAL DRAWING ROOFING MATERIAL -' FOR ROOF, SEE ARCHITECTURAL DRAWING FILL CAVITY W/ FIBER GLASS INSULATION CONTROL BOX 2" STRAP OR DRAW BAND INSULATED (1" THICK) FLEXIBLE DUCT FOR SIZE AS NOTED ON PLANS. MAXIMUM LENGTH IS 10'-0" CAULK & SEAL AT BOTH DIFFUSER NECK AND FLEXIBLE DUCT CONNECTION. TIGHTEN WITH DRAW BAND. INSULATE TOP OF DIFFUSER f WITH 2" THICK FIBERGLASS BLANKET INSULATION. EXPOSED CEILING TEE REGULAR CEILING PANEL DIFFUSER CONNECYRD"N DETAIL NOT TO SCALE SMOKE DETECTOR INSIDE OF ROOFTOP UNIT MOTORIZED OUTSIDE PROVIDE ACCESS DOOR AIR DAMPER 0/A INTAKE �i i FJ HOOD I I 0 ROOFTOP AIR HANDLER 3/16" THICK GALVANIZED TIE DOWN OF S I RTU TO ROOF CURB WITH 1/2" DIAMETER STAINLESS STEEL BOLTS (TYPICAL OF 8 - 2 PER CORNER) INSTALLATION SHALL MEET WIND LOADS SUPPLY RETURN FOR FLORIDA BUILDING CODE AIR AIR ROOF JOIST (TYPICAL) NOTE: SEE ARCHITECTURAL 1. COORDINATE ROOF OPENINGS WITH STRUCTURAL. DRAWING KEEP OPENING TO MINIMUM AS REQUIRED, ALSO COORDINATE OPENINGS WITH BAR JOIST OR ROOF TRUSS LOCATION. NOTES: 1. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 2. IF INDICATED STRAIGHT RUN CANNOT BE OBTAINED, A FLOW - STRAIGHTENER SHALL BE PROVIDED AT BOX INLET. FAN BOX CONNECTRt."o"NS (IER iES DETAIL NOT TO SCALE E Copyright 2004 ACi, Inc. IHSA HUMAN SERVICES ASSOCIATES, INC. C� C:� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida 0 ACi ASSOCIATED CONSULTING INTEKNATI0NAL ■ DEVELOP NLENT. DLAAGEME_VT.ARCHITECTURE FL AA0002940 955 N. PENNSYLVANJA AVE. tXIINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unoutharized use, dis— closure, dissemination, or duplication of any of the information contolned herein may result in liability under applicable laws. E 3D � /-30' AIR -TERMINAL BOX Checked By: FLEX CONN. [—] r—] 00 NFO®BSTATE _--� FVICE: LORIDA P EESENG.COM 5638.7024 File Name: _2010416.dNvg Phase: PERMIT DOCUMENT Sheet Name: rFAN� L I 3 I ' DAMPER INTERNALLY LINED W/ 1 1/2" LINER SIZE AS INDICATED CONTROLLER 20 FT MINIMUM UNLESS DISTANCE TO HEATING COILT 24 ON DRAWING v-30' DIFFUSER IS LESS 5/8" SUPPORT— ROD D —� SPRING VIBRATION BOX ISOLATOR DAMPER CONTROLLER R=D NOTES: PART PLAN (ELEV.) 1. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 2. IF INDICATED STRAIGHT RUN CANNOT BE OBTAINED, A FLOW -STRAIGHTENER SHALL BE PROVIDED AT BOX INLET. HEATING COIL 3. DUCT AND PLENUM LINER SHALL BE PERMACOTE LINACOUSTIC R-300 LINER FLEX CONN. BY SCHULLER. AIR TERMINAL BOX CONNECT10"NS IF (HARD DUCTEDI DETAIL FAN IIID — — NOT TO SCALE NOTES: 1. BOX SENSOR SHALL BE ORIENTED IN SAME PLANE AS ELBOW AND BE WITHIN 10' OF HORIZONTAL OR PER MANUFACTURER'S RECOMMENDATION. 2. IF INDICATED STRAIGHT RUN CANNOT BE OBTAINED, A FLOW - STRAIGHTENER SHALL BE PROVIDED AT BOX INLET. FAN BOX CONNECTRt."o"NS (IER iES DETAIL NOT TO SCALE E Copyright 2004 ACi, Inc. IHSA HUMAN SERVICES ASSOCIATES, INC. C� C:� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida 0 ACi ASSOCIATED CONSULTING INTEKNATI0NAL ■ DEVELOP NLENT. DLAAGEME_VT.ARCHITECTURE FL AA0002940 955 N. PENNSYLVANJA AVE. tXIINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unoutharized use, dis— closure, dissemination, or duplication of any of the information contolned herein may result in liability under applicable laws. Issues and Revisions No. Date I Issue/Revision I By E ATES BOBESF0_ CONSULTING ENGINEERS Checked By: 150 CIRCLE DRIVE MAITLAND, FL 32751 407.628.0882 FAX. [—] r—] 00 NFO®BSTATE Project No.: 0416 FVICE: LORIDA P EESENG.COM 5638.7024 Issues and Revisions No. Date I Issue/Revision I By DETAILS HVAC SHEET NUMBER M-201 Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416.dNvg Phase: PERMIT DOCUMENT Sheet Name: DETAILS HVAC SHEET NUMBER M-201 S �L ROOF TOP UNIT SCHEDULE FAN DATA UNIT DX. COOLING COIL DATA ELECTRIC HEATING COIL ELECTRICAL MEZZANINE OFFICE AREA UNIT MIN AREA SERVED OUTSIDE CFM EXT. RPM BHP HP FILTER DATA ENT. AIR LVG. AIR MBH MBH FPI FACE RTU -2 ENT. AIR LVG. AIR KW VOLTS PHASE STAGE COMPRESSOR _ OUTDOOR FAN FM TOTAL MOPD VOLTS PHASE EE MANUFACTURER/MODEL NUMBER AIR E.S.P. -- +800 OPEN OFFICE AREA (WEST) NO/SIZE DB 'F WB 'F DB 'F DB 'F TOTAL SENSIBLE AREA O ROWS 'F .F 1/4 170 - - 6.9 10 N0. RLA LRA N0. FLA MCA 4,200 0.80 EER 1/2 RTU -1 CONFERENCE ROOMS #7, 8 & 9 1050 4,500 1.0 955 2.82 3.7 4/20"x20%2° 80.4 67.3 57.6 56.6 153.5 111.1 15 11.1 4 -- -- -- --- -- -- 2 23 EA. 146 EA. 2 1.4 65.2 80 208 3 9.2 CARRIER 50TFF014 RTU -2 RECEPTION/ENTRY/OFFICE AREA 450 4,400 1.0 919 2.71 2.9 4/20"x20"x2" 77.9 65.4 58.4 56.9 120.4 94.9 15 10.0 3 70 87 32* 208 3 2 2 15.8 EA. 130 EA. 2 1.4 92.8 100 208 3 9.0 CARRIER 50TFF012 RTU -3 OPEN OFFICE AREA/CONF. ROOMS 1300 5,600 1.0 1084 4.47 5.25 4/20"x20" x2" 80.4 67.3 59.9 58.7 157.5 123.7 15 11.1 4 70 83 32* 208 3 . 2 2 23 EA. 146 EA. 2 1.4 102.1 110 208 3 9.2 CARRIER 50TFF014 RTU -4 OPEN OFFICE AREA ( WEST) 700 4,000 1.0 875 2.21 2.4 4/20"x20°x2" 79.4 66.5 58.7 57.2 118.9 89.8 15 10.0 3 70 80 16* 208 3 2 2 15.8 EA. 130 EA. 2 1.4 90.6 100 208 3 9.0 CARRIER 50TFF012 RTU -5 OPEN OFFICE AREA (CENTER) 700 4,000 1.0 875 2.21 2.4 4/20"x20°x2" 79.4 66.5 58.7 57.2 118.9 89.8 15 10.0 3 70 80 16* 208 3 2 2 15.8 EA. 130 EA. 2 1.4 90.6 100 208 3 9.0 CARRIER 50TFF012 RTU -6 OPEN OFFICE AREA (EAST) 700 4,000 1.0 875 2.21 2.4 4/20N20%2" 79.4 66.5 58.7 57.2 118.9 89.8 15 10.0 3 70 80 1 fi* 208 3 2 2 15.8 EA. 130 EA. 2 1.4 90.6 100 208 3 9.0 CARRIER 50TFF012 1. MANUFACTURER SHALL PROVIDE SINGLE POINT POWER CONNECTION, ROOF CURB, 25% O.A. MOTORIZED DAMPER, HEAD PRESSURE CONTROL, CONDENSER COIL HAIL GUARD, AND UV LAMPS. * ELECTRIC HEATERS ARE RATED AT 240V. ACTUAL OUTPUT OF HEATER WILL BE 75% OF RATED KW. BUILDING AIR BALANCE SCHEDULE AREA SERVED UNIT SUPPLY AIR RETURN AIR OUTSIDE AIR EXHAUST AIR NET EFFECT MEZZANINE OFFICE AREA AHU-2 4200 3300 900 -- +900 CONFERENCE RMS 7,8,&9 RTU -1 4500 3450 1050 -- +1050 RECEPT/ENTRY/OFFICES RTU -2 4400 3950 450 -- +450 OFFICE/CONFERENCE RMS RTU -3 5600 4300 1300 -- +1300 OPEN OFFICE AREA ( EAST) RTU -4 4000 3400 600 -- +600 OPEN OFFICE AREA (CENTER) RTU -5 4000 3200 800 -- +800 OPEN OFFICE AREA (WEST) RTU -6 4000 3300 700 -- +700 SUB TOTAL -- -- -- -- -- +5800 RESTROOMS 128 & 129 EF -1 CBCS RR 106 EF -2 RESTROOMS 148,149 & J.C. EF -3 ELECTRIC ROOM 153 EF -4 SUB TOTAL -- TOTAL (NET DIFFERENCE) -- -- -- 1200 -1200 -- -- -- 150 -150 -- -- -- 500 -500 -- -- -- 500 -500 -- -- -- -- -2350 UNIT UNIT +3450 FAN POWERED VAV OX PERFO"'RMANCE DATA ""ERIES FLOW) DX. COOLING COIL DATA CONSTRUCTION DATA ELECTRIC HEATING COIL ELECTRIC DATA MIN DATA MAX RADIATED SOUND POWER 100% PRIM. FLOW R UNIT FAN ELECTRIC CONTROL do UNIT UNIT MAX AP ENT. AIR F E,S.P, 0.5 INLET Ps 1.0 INLET Ps FAN No. STATIC IN. AMPERAGE HEATER KW HEATER NUMBER SIZE CFM (IN W.G.) 455 - - (IN W.G.) 2 4 6 7 2 4 6 7 HP LOREN COOK GN -920 (120V) (20" ACCESS+ FB -1 1218 1500 0.08 FR ,f 0.80 71 62 51 50 73 64 52 50 1/4 170 - - 6.9 10 RH SIDE FB -2 1224 1800 0.08 4,200 0.80 71 60 44 42 73 62 46 43 1/2 2.4 8.9 10 RH SIDE FB -3 0811 600 0.08 7.3 0.60 60 51 35 35 63 54 40 39 1/8 -- 3.2 - - RH SIDE FB -4 0811 600 0.08 301 - - 0.80 60 51 35 35 63 54 40 39 1/8 LOREN COOK GC -720 3.2 - - RH SIDE PERFORMANCE DATA IS BASED ON TEST CONDUCTED IN ACCORDANCE WITH INDUSTRY STANDARD ARI 880; 885-90 AND 880-94. ALL FAN POWERED BOXES SHALL BE ENVIRO-TEC MODEL CRF (SERIES FLOW) WITH FAN SET AT LOW SPEED, FOIL FACE INSULATION, 1 ALUMINUM AND FILTER RACK WITH DISPOSABLE FILTER. TITUS 50F G-6 RETURN WALL ALL B XES SHALL HAYE SINGLE POINT ELECTRICAL CONNECTION 208V, 30, 60 CYCLES WITH BUILT IN DISCONNECT IN PANEL DOOR. 20 + ACCESS LISTED AS YOU FACE OUTLET OF FAN POWERED BOX. PROVIDE MINIMUM 3 FEET OF ACCESS CLEARANCE. REMARKS SEE NOTE #1 SEE NOTE #1 SEE NOTE #1 SEE NOTE #1 SEE NOTE #1 SEE NOTE #1 v v NO, AIR HANDLING UNIT SCHEDULE FAN DATA DX. COOLING COIL DATA CONSTRUCTION DATA ELECTRIC HEATING COIL ELECTRIC DATA FILTER DATA SEER MODEL MANUFACTURER MODEL MANUFACTURER/ R UNIT LOCATION AREA OUTSIDE SERVED AIR CFM TOTAL MINDCN. OUTLET OUTLET RPM BHP HP ENT. AIR F LVG. AIR TOTAL F MBH SENS. MBH FACE F.P.I No. STATIC IN. ENT. VG. KW, AMPS VOLTS PHASE UNIT MCA MOPD TYPE CLEAN P.D. IN. NO./SIZE NUMBER 455 - - 120 1 I w�G' PEG. LOREN COOK GN -920 SEE NOTE #1 EF -2 DB WB DB WB 1.9 � ROWS FR ,f - - - - -- 170 - - 120 1 60 LOREN COOK GC -420 SEE NOTE #2 MECH. RM OfFIC�S/LIQZ. OFFICE AID 900 4,200 1.0 -- 2000 --- -- 2.4 80.0 1 67.0 59.31 57.9 123.6 93.9 17 10.1 2 -- DUCT HEATER 208 3 7.3 15 DISP. 2" 4/16"x24"x2" -- CARRIER 40RM012 SEE NOTE #1 NOTES: 1. EXISTING AIR HANDLING UNIT TO BE RELOCATED. PROVIDE NEW INSULATED CABINET PANEL FOR RETURN AIR OPENING. REMOVE BOTTOM PANEL FOR NEW RETURN AIR OPENING. CONDENSING T SCHEDULE UNIT BCU/HR CONSTRUCTION DATA COMPRESSOR DATA CONDENSER FAN ELECTRICAL MANUFACTURER/MODEL NUMBER AT ARI E E R �� - MANUFACTURER/MODEL REMARKS CLASS CONDITION DISCH NO. HP/KW RLA LRA NO. HP/KW FLA MCA FUSE VOLTS PHASE CYCLE 3 VOLTS CU -2 -- -- 2 - - - -- -- 1 -- --� -- -- 208 3 60 CARRIER (EXISTING) SEE NOTE #1 1. EXISTING NOMINAL 10 TON CONDENSING UNIT SERVING RELOCATED AHU-2 TO REMAIN IN PLACE, PROVIDE NEW REFRIGERANT PIPING. FAN SCH ED U LE UNIT NUMBER PERFORMANCE DATA CONSTRUCTION DATA MOTOR DATA ELECTRICAL MANUFACTURER/MODEL REMARKS CFM SP RPM SONES BHP FAN TYPE CLASS ROT DISCH HP WATTS START VOLTS PHASE CYCLES EF -1 1200 50" 867 4.8 .285 INLINE CENTRIFUGAL - - - - - - -- 455 - - 120 1 60 LOREN COOK GN -920 SEE NOTE #1 EF -2 150 .50" 842 1.9 -- CEILING CABINET - - - - - - -- 170 - - 120 1 60 LOREN COOK GC -420 SEE NOTE #2 EF -3 500 .50" 1088 2.5 -- INLINE CENTRIFUGAL - - - - - - -- 323 - - 120 1 60 1 LOREN COOK GN -720 1 SEE NOTE #1 EF -4 500 .50" 1190 5.3 -- CEILING CABINET - - - - - - -- 301 - - 120 1 60 LOREN COOK GC -720 SEE NOTE #2 NOTES: 1, MANUFACTURER SHALL PROVIDE ROOF VENT CAP 'MTH CURB, VIBRATION ISOLATORS AND SOLID STATE VARIABLE SPEED CONTROLLER. 2. MANUFACTURER SHALL PROVIDE ROOF VENT CAP WITH CURB, ALUMINUM GRILLE, AND SOLID STATE VARIABLE SPEED CONTROLLER. ELECTRICHEATING"SCHEDULE UNIT AREA HEATINGINPUT OUTPUT OUTPUT # OF NR TEMP('F) DUCT SIZE ELECTRICAL DATA NUMBER SERVED AHU CFM SPE KW KW MBH STEPS ENT LVG W(IN) H(IN) VOLTS PHASE CYCLE FLA MANUFACTURER/MODEL EDH-1 NOT USED FDH-2 MEZZ. OFF. AREA I AHU-2 4,200 1 INSERT 30 22.5 92.1 -- 63 83.3 24 20 208 1 3 60 1 53.8 MARKEL/CHMS N OTES: 1. MANUFACTURER SHALL PROVIDE FAN INTERLOCK SWITCH, OVERTEMPERATURE CONTROL, OVER CURRENT PROTECTION, MERCURY CONTACTORS, AND ELECTRONIC SCR CONTROLLER. REMARKS SEE NOTE #1 VARIABLE AIR VOLUME BO"XES PERFORMANCE MARK FRAME MOUNT DIFFUSER NECK C.F.M. N.C. pp' PARI DAMPER FINISH SURFACE CONSTRUCTION MANUFACTURER/MODEL 1.0' APs SIZE SIZE RANGE MAX IN.W.G. NUMBER SERVICE MOUNT C.F.M.G SIZE L'X H" N.C. FRAME MAY,IN * � ' DAMPER GRID CONSTRUCTION FINISH MANUFACTURER/MODEL G-1 RETURN CLG 0-1000 2412 20 LAY -IN 0.054 NO 1/2° ALUMINUM WHITE TITUS 50F G-2 RETURN CLG 1001-2000 2424 20 LAY -IN 0.054 NO 1/2" ALUMINUM WHITE TITUS 50F G-3 EXH/RET CLG 0-600 12x12 23 SURFACE 0.073 NO 1/2" ALUMINUM WHITE TITUS 50F G-4 EXHAUST CLG 0-100 6x6 11 SURFACE 0.054 NO 1/2" ALUMINUM WHITE TITUS 50F 0-5 RETURN WALL 0-1300 2416 20 SURFACE 0.054 YES 1/2" ALUMINUM WHITE TITUS 50F G-6 RETURN WALL 0-5000 48x48 20 SURFACE 0.024 YES 1/2" ALUMINUM WHITE TITUS 50F G-7 TRANSFER DOOR 0-500 2424 20 SURFACE 0.028 NO -- ALUMINUM WHITE TITUS CT -700L PAINT FLAT BLACK INSIDE OF DUCTS BEHIND EXHAUST GRILLES ALL GRILLES AND REGISTERS SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50 IN COMPLIANCE WITH SECTIONS 603.15 AND 603.15.1 OF THE FLORIDA BUILDING CODE VARIABLE AIR VOLUME BO"XES PERFORMANCE MARK FRAME MOUNT DIFFUSER NECK C.F.M. N.C. pp' PARI DAMPER FINISH SURFACE CONSTRUCTION MANUFACTURER/MODEL 1.0' APs SIZE SIZE RANGE MAX IN.W.G. 1.0' APs 3.0' APs ELETRIC HEAT PANEL NUMBER CFM CD -1 LAY -IN CEILING 18x18 SEE DING SEE DWG. 25 0.13 4 -WAY NO WHITE 24x24 ALUMINUM TITUS TMS -AA CD -2 SURFACECEILING 12x12 SEE DWG SEE DWG. 25 0.13 4 -WAY NO WHITE --- ALUMINUM TITUS TMS -AA CD -3 SURFACE EXPOSED 27"0 12"0 0-600 28 0.08 4 -WAY NO WHITE --- ALUMINUM TITUS TMRA-AA CD -4 SURFACE EXPOSED --- -- --- -- -- 4 -WAY -- GREEN --- ----- EXISTING WR -1 SURFACE WALL 18x8 18x8 0-500 22 0.08 2 -WAY NO WHITE --- ALUMINUM TITUS 30OFS WR -2 SURFACE WALL 12x6 12x6 0-250 20 0.08 2 -WAY NO WHITE --- ALUMINUM TITUS 30OFS REMARKS: 1. SEE ARCHITECTURAL CEILING PLAN FOR DIFFUSER FRAME TYPE. 2. MECHANICAL CONTRCTOR TO CONFIRM EXISTING DIFFUSER AND INLET SIZES. PAINT DIFFUSER IN COLOR AS DIRECT BY ARCHITECT. 3.ALL DIFFUSERS AND REGISTERS SHALL HAVE A MINIMUM FLAME SPREAD RATING OF NOT OVER 25 AND A MINIMUM SMOKE DEVELOPED RATING OF NOT OVER 50 AND SHALL BE IN COMPLIANCE WITH SECTIONS 603.15 AND 603.15.1 OF THE FLORIDA BUILDING CODE, MECHANICAL. VARIABLE AIR VOLUME BO"XES PERFORMANCE ❑ BOBIES ASSOCIATES A CONSULTING ENGINEERS VOICE: 407.628.0882 FAX: 407.628.7024 [_]-11O CIRCLE DRIVE MAIIIAND, FL 32151 E-MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 DISCHARGE NOISE CRfTERIA(NC) RADIATED MOISE CRITERIA (NC) 0.5'A Ps 1.0' APs 3.0' AN 0.5' APs 1.0' APs 3.0' APs ELETRIC HEAT NUMBER CFM pps eIPNt MANUFACTURER ANDEL\SIZE M DEL MODEL MODEL MODEL MODEL DEL VOLTSKW PHASE CYCLE SOR SDR SDR SDR SDR SDR-SA VAV-1 500 0.03 -- -- -- 24 -- -- 24 - -- -- -- ENVIRO-TEC SDR -8 VAV-2 400 0.02 -- -- -- 23 -- -- 21 - -- -- -- ENVIRO-TEC SDR -8 VAV-3 800 0.03 -- -- -- 27 -- -- 27 - -- -- -- ENVIRO-TEC SDR -10 VAV-4 400 0.03 -- -- -- 23 -- -- 21 - -- �- -- ENVIRO-TEC SDR -8 NOTE: MANUFACTURER TO PROVIDE 24 VOLT TRANSFORMER, ELECTRONIC CONTROLS, AND FOIL FACED INSULATION. © Copyright 2004 ACI', Inc. I HSA HUMAN SERVICES ASSOCIATES, INC. C�BC�S COMMUNITY BASE CARE SEMINOLE Sanford, Florida ACi ASSOCIATED C01NSULTI-NI G IN i'ERN I i'IUNA[ AL N DEVELOPMENT.NUi NIrAGEi%LEN'I'.ARCI I'ECI'URE FL AA0002940 955 N. PENNSYLVANIA AVE. WINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis- closure, dissemination, or duplication of any of the Information contained herein may result in liability under applicable laws. B ❑ BOBIES ASSOCIATES A CONSULTING ENGINEERS VOICE: 407.628.0882 FAX: 407.628.7024 [_]-11O CIRCLE DRIVE MAIIIAND, FL 32151 E-MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 [-] xij 25 VV_, Issues and Revisions V. Date Issue/Revision By 1 02/23/05 VF- / REVISION ABJr Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416. File Name: _2010416.dwg Phase: PERMIT DOCUNMNT Sheet Name: SCHEDULES & DETAILS - HVA SHEET NUMBER M-3el ic ro /—EXISTING UNDERGROUND !I .,_.- __ _®, ._- _® ®�- _® _® — - -... — e— — — _- _® -._._ — .,.e- — 1 EXISTING UNDERGROUND SANITARY PIPE TO REMAIN v 1 [ i 3 C I 1' F - r7 =. 3 1/8-=1 CVIC-rlkt , r -VI I kir-117 nd - HEK NOTES DEMOLITION - HVAC 0 REMOVE EXISTING AHU-3 AND HANDLE AS DIRECTED BY OWNER REPRESENTATIVE. REMOVE EXISTING TEMPERATURE CONTROLS FOR AIR HANDLING UNIT. N ITMEZZA SCALE: 1 8 = 02 REMOVE EXISTING ELECTRIC DUCT HEATER AND HANDLE AS DIRECTED BY OWNER REPRESENTATIVE. DISCONNECT POWER SUPPLY TO ELECTRIC HEATER. O REMOVE EXISTING AHU-2 AND RELOCATE WHERE INDICATED ON DRAWING M1.1. DISCONNECT POWER SUPPLY TO SUPPLY FAN. REMOVE EXISTING TEMPERATURE CONTROLS FOR AIR HANDLING UNIT. 04 REMOVE EXISTING ELECTRIC DUCT HEATER AND HANDLE AS DIRECTED BY OWNER REPRESENTATIVE. DISCONNECT POWER SUPPLY TO ELECTRIC HEATER. O REMOVE EXISTING SUPPLY AIR DUCTWORK AND SUPPORTS UNLESS OTHERWISE NOTED. PROPERLY DISPOSE OF SHEET METAL DUCTWORK AND DUCT INSULATION. O6 REMOVE EXISTING RETURN AIR DUCTWORK AND SUPPORTS, PROPERLY DISPOSE OF SHEET METAL DUCTWORK AND DUCT INSULATION. (7 REMOVE EXISTING EXHAUST AIR DUCTWORK AND SUPPORTS. PROPERLY DISPOSE OF SHEET METAL DUCTWORK. REMOVE EXISTING EXHAUST FAN ON ROOF. TEMPORARILY CAP ROOF OPENING FOR REUSE. O8 REMOVE EXISTING PROPELLER ROOF EXHAUST FAN AND VENT CAP. G.C. TO PATCH EXISTING ROOF OPENING. DISCONNECT EXISTING POWER SUPPLY AND CONTROLS, O REMOVE EXISTING ROOF EXHAUST VENT CAP AND CONNECTING DUCTWORK. TEMPORARILY CAP EXISTING ROOF OPENINGS FOR REUSE, 10 REMOVE EXISTING REFRIGERANT PIPING FROM CONNECTION TO AIR HANDLING UNIT TO CONNECTION TO ITS RESPECTIVE CONDENSING UNIT. PROPERLY EVACUATE REFRIGERANT FROM THE PIPING AND DISPOSE OF PIPING AS DIRECTED BY THE OWNER REPRESENTATIVE. G.C. TO PATCH PIPE PENETRATION AT EXISTING WALL. 11 EXISTING CONDENSING UNITS TO REMAIN. CAP ENDS OF CONNECTING REFRIGERANT PIPING UNTIL NEW PIPING IS INSTALLED. 12 NOT USED. 13 EXISTING OUTDOOR INTAKE WALL OPENING TO BE REMOVED AND G.C. TO PATCH EXTERIOR `"TALL. 14 EXISTING OUTDOOR INTAKE WALL OPENING TO BE REMOVED AND G.C. TO PATCH EXTERIOR WALL. 15 REMOVE EXISTING RETURN AIR GRILLES. 16 REMOVE EXISTING SUPPLY AIR DIFFUSERS AND HANDLE AS DIRECTED BY OWNER REPRESENTATIVE. 17 REMOVE EXISTING SUPPLY AIR DIFFUSERS OR GRILLES. 18 REMOVE EXISTING EXHAUST AIR DUCTWORK AND SUPPORTS, REMOVE VENT CAP ON ROOF, G.C. TO PATCH EXISTING ROOF OPENINGS UNLESS OTHERWISE NOTED. 19 REMOVE EXISTING CEILING EXHAUST FAN AND SUPPORTS. DISCONNECT POWER SUPPLY AND CONTROLS, HEX NOTES, DEMOLITION - PWMBING 21 REMOVE EXISTING PLUMBING FIXTURES, REMOVE AND CAP SANITARY PIPING CONNECTIONS TO FIXTURES BELOW EXISTING FLOOR. REMOVE EXISTING VENT PIPING INCLUDING VENT THROUGH ROOF. REMOVE EXISTING WATER PIPING FROM CONNECTION TO FIXTURES TO ABOVE CEILING AND CAP REMAINING ENDS OF PIPING. REUSE ANY WATER CLOSET OR URINAL IF IN GOOD CONDITION. G.0 TO PATCH FLOORING AND ROOF. 22 REMOVE EXISTING FLOOR DRAIN AND CAP SANITARY PIPE CONNECTIONS BELOW THE FLOOR. 23 EXISTING FLOOR DRAIN TO REMAIN. ADJUST HEIGHT OF DRAIN TO MEET NEW FLOOR HEIGHT. 24 EXISTING WATER CLOSET TO REMAIN. EXISTING SANITARY AND VENT PIPING TO REMAIN. PROVIDE NEW ANGLE STOP AND FLEXIBLE CONNECTION TO EXISTING FIXTURE. 25 EXISTING WALL HUNG LAVATORY TO REMAIN, EXISTING SANITARY AND VENT PIPING TO REMAIN. PROVIDE NEW ANGLE STOPS AND FLEXIBLE CONNECTIONS TO FIXTURE. PROVIDE NEW ADA APPROVED TRAP WRAP AND WATER PIPING FOAM PROTECTIONCOVER. 26 REMOVE EXISTING FLOOR DRAIN IN MEZZANINE. REMOVE CONNECTING PIPING IN CEILING SPACE BELOW TILL PIPING PENETRATES AN EXISTING 'NALL OR FLOOR TO REMAIN. CAP PIPING AT REMAINING END FLUSH TO EXISTING WALL OR FLOOR. 27 EXISTING ELECTRIC WATER HEATER, CONNECTING PIPING AND APPURTENANCES TO REMAIN, 28 EXISTING JANITOR SINK TO REMAIN. EXISTING SANITARY AND VENT PIPING TO REMAIN. EXISTING WATER PIPING AND FAUCET TO REMAIN. CLEAN EXISTING FIXTURE AND FAUCET, 29 REMOVE EXISTING ABANDONED GAS WATER HEATERS IN MEZZANINE. 30 EXISTING 1" DOMESTIC COLD WATER ABOVE CEILING TO REMAIN. CONTRACTOR TO VERIFY EXACT LOCATION OF PIPE. REMOVE CW PIPING IN WALL. 31 EXISTING UNDERGROUND SANITARY SHALL BE REMOVE TO POINT WHERE NEW SANITARY PIPING CAN CONNECT TO EXISTING. CONTRACTOR TO CONFIRM EXISTING SANITARY PIPE INVERT AND SLOPE, 32 EXISTING COLD WATER SUPPLY PIPING TO BE REMOVED FROM CONNECTION OF REMOVED PLUMBING FIXTURES TO ABOVE CEILING. CONTRACTOR OPTION TO REMOVE PIPING ALL THE WAY TO CONNECTION BACK AT MAIN SUPPLY (REAR OF BUILDING). CAP END OF REMAINING PIPING. CONTRACTOR TO REMOVE ALL HOT WATER PIPING AND WATER HEATER AS REQUIRED SERVING THE EXISTING REMOVED PLUMBING FIXTURES. Copyright 2004 ACi, Inc. i HSA HUMAN SERVICES ASSOCIATES, INC. (D C� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i ASSOCIATED CONSULTING INTERNATIONAL DEVELOP:NLENT. AI1�rAGEiVIENT. ARCHITECTURE FL AA0002940 955 N. PENNSYL�fANIA Al T. WENTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted materid information belonging exclusively to ACI, Inc. Any unauthorized use, dis— closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. Issues and Revisions No. Date Issue/Revision By Date: November 30, 2004 Checked By: Drawn By: Project No.: 041 G File Name: _1010416.dNvg Phase: PERMIT DOCUMENT Sheet Name: 1 ST FLOOR AND MEZZ, PLANS - DEMOLITION HVAC & PLUMBING SHEET NUMBER 0113' CONSULTING ENGINEERS 150 CIRCLE DRIVE MAITLAND, FL 32751 VOICE: 407.628.0882 FAX: 407.628 7024 C E E—MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 Issues and Revisions No. Date Issue/Revision By Date: November 30, 2004 Checked By: Drawn By: Project No.: 041 G File Name: _1010416.dNvg Phase: PERMIT DOCUMENT Sheet Name: 1 ST FLOOR AND MEZZ, PLANS - DEMOLITION HVAC & PLUMBING SHEET NUMBER r PLUMBING SYMBOL LEGEND v SANITARY WASTE LINE - BELOW FLOOR CW AIR LINE WC [)0 Co WATER CLOSET A WC -1 SANITARY WASTE LINE - ABOVE FLOOR 0--- PIPE ELBOW UP U URINAL ----- SANITARY VENT LINE C PIPE ELBOW DOWN L ® WALL MOUNTED LAVATORY 2" DOMESTIC COLD WATER WCO Illy- WALL CLEANOUTL 3/4" COUNTER TOP LAVATORY - 1 1/2" DOM. HOT 'NATER 140' F FCO O -I - - FLOOR CLEANOUT --- BALL VALVE - - - - 1 1/4" DOMESTIC HOT WATER RECIRCULATED GOO 0- - e GROUND CLEANOUT 1/2" BALL BUTTERFLY VALVE / - - - -T- TEMPERED WATER 100' F VTR �- '1ENT THRU ROOF -� �- CHECK VALVE - - - F - FILTERED WATER RL O ROOF LEADER CS -1 INLINE PUMP - - - S - SOFT WATER RD ® ROOF DRAIN -� I f -- UNION '• SD STORM DRAIN -® BELOW FLOOR - - FLOOR DRAIN �(J TEMP. & PRESSURE RELIEF VALVE - SD STORM DRAIN - ABOVE FLOOR HD O HUB DRAIN COCK GR •, ® GREASE WASTE LINE- POINT OF CONNECTION BELOW FLOOR NEW TO EXISTING GAS COCK - CON - CONDENSATE DRAIN HB HOSE BIBB �_ WATER ARRESTOR G NATURAL GAS LINE HBR- HOSE BIBB RECESSSED BALANCING VALVE AD AREA DRAIN ESE EMERGENCY SHOWER/ S SINK EYEWASH ADR AIR DRIER COMPRESSED AIR EWH ELECTRIC WATER HEATER SR _ SANITARY RISER DIAGRAM AF AIR FILTER COMPRESSED AIR EWC ELECTRIC WATER COOLER SE SEWAGE EJECTOR AFF ABOVE FINISHED FLOOR FL FLOOR SH SHOWER AR AIR RISER DIAGRAM FS FLOOR SINK SS SERVICE SINK BTU BRITISH THERMAL UNIT GPH GALLON PER HOUR STR STORM RISER DIAGRAM CA COMPRESSOR COMPRESSED AIR GR GAS RISER DIAGRAM TEMP TEMPERATURE CLG CEILING HD HUB DRAIN TW TEMPERED WATER CHDW CHILLER, DRINKING WATER HW HOT WATER UR URINAL CS COUNTER SINK KS KITCHEN SINK WC WATER CLOSET CW COLD WATER KW KILOWATT W/ WITH OF DEGREES FARENHEIT LAV, L LAVATORY WHE WATER HEATER, ELECTRIC DISP DISPOSER MBH MEGA BTU PER HOUR WHG WATER HEATER, GAS DN DOWN MS MOP SINK WF WATER FILTER DF DRINKING FOUNTAIN NIC NOT IN CONTRACT WR WATER RISER DIAGRAM B TEMP. DIFFERENCE IN 'F OD OVER FLOW DRAIN WS WATER SOFTENER DWG DRAWINGPC PUMP, CIRCULATING DOMESTIC HOT WATER EDF ELECTRIC DRINKING FOUNTAIN PD PLANTER DRAIN EFF EFFICIENCY PS PUMP, SUMP 2.1 GALLON EXPANSION TANK 22" HEAT TRAP WILKINS WXTP-8 OR AMTROL I ; I 1 1 P&T RELIEF DISCHARGE RUN FULL SIZE COPPER EXISTING ELECTRIC WATER HEATER TO SPILL OUTSIDE OF BUILDING PIPE TO SPILL OVER FLOOR DRAIN OR OUTSIDE OF BUILDING 3" I 0 3/4" TO SCALE HOT WATER 1 --- --------------------� VACUUM BREAKER COLD WATER RELIEF VALVE (TEMP. & PRESS.) UNION (TYPICAL) WATER HEATER DRAIN ATER PAN GALVANIZED METAL 18 GAUGE MIN) PROVIDE 'NATER HEATER SUPPORT BASE SEE DETAIL TO MATCH /� 2" X 2" X 1/4' ANGLE IRON PAN SIZE , j \ �! LENGTH AS REQUIRED - PAINT WITH RUST INHIBITING PAINT 14 12" GALVANIZED STEEL PLATFORM TO MATCH PAN SIZE L C L 1 1/8" MIN. TO 2 1/4" MAX. FLOOR DRAIN DETAIL NOT TO SCALE TRAP PRIMER CONNECTION VIDE P -TRAP OR UEEP SEAL TRAP PLUMBING FIXTURE CONNECTION SCHEDULE SYMBOL DESCRIPTION CW HW WASTE VENT REMARKS WC -1 WATER CLOSET 1/2"- - 3" 2" - - - WC -2 WATER CLOSET 1/2" - - 3" 2" HANDICAP UR -1 URINAL 3/4" - - 2" 1 1/2" HANDICAP L-1 LAVATORY 1/2" 1 1/4" COUNTER L-2 LAVATORY 1/2" :t�j_ 1 1/211 1 1/4' HANDICAP EWC-1 ELECTRIC WATER COOLER 1/2" 1 - - 1 1/4" 1 1/4" HANDICAP CS -1 COUNTER SINK 1/2" 1/2" 1 1/2" 1 1/4" - - - CS -2 F__1 COUNTER SINK 1/2" - - 1 1/2" 1 1/4" - - - STANDARD FRAME AND COVER FINISH FLOOR A. - TEST TEE THREADED CLEANOUT PLUG ACCESS COVER AND FRAME FINISED H WALL SURFACE CLEANOUT NOT TO SCALE DIAL TYPE THERMOMETER TEMPERED WATER SUPPL THERMOSTAIC MIXING VALVE TMV-1 (TEMPERED WATER) 1 HOT WATER SUPPLY FROM 22" HEAT TRAP TO TO SCAT E NO -HUB COUPLING CONCRETE FLOOR SLAB 1/2" TEMPERED WATER RETURN TEMPERED WATER CIRCULATING PUMP CP -1 BALANCING VALVE SET FOR 3 GPM 1 /2" BY-PASS COLD WATER SUPPLY NOTES: 1. DESIGN BASED ON LEONARD VALVE CO, MODEL TM25-E-RF-LTR. MANUFACTURER TO PROVIDE WALL MOUNTING BRACKET. 2. PROVIDE CIRCULATING PUMP AND BY-PASS WHERE INDICATED ON DRAWINGS. NOT ALL MXING VALVES WILL HAVE THESE ITEMS. kTIC MIXING VALVE DETAIL r I uI ID ISHED FLOOR OR SCHEDULE 40 PVC CONSTRUCTION ULCr JCJiL If(P _HUG DRAIN DETAIL NOT TO SCALE - AID /'An WITU DISHWASHER INDIRECT CON'"NEC710"*N DETAL NOT TO SCALE PLUMBING GENERAL NOTES 1. ALL WORK SHALL CONFORM WITH THE 2001 FLORIDA BUILDING CODE, WITH 2002 AND 2003 REVISIONS AND THE CITY OF SANFORD BUILDING DEPARTMENT REQUIREMENTS. 2. ALL HANDICAP FIXTURES SHALL BE MOUNTED IN ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA) AND THE 2001 FLORIDA BUILDING CODE CHAPTER 11 - FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION. 3. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY EXACT LOCATIONS OF UTILITIES IN FIELD. 4. PRIOR TO START OF CONSTRUCTION, CONTRACTOR SHALL VERIFY ALL EXISTING BUILDING CONDITIONS. 5. COORDINATE WORK WITH ALL OTHER TRADES TO AVOID INTERFERENCES. 6. INSTALL ALL WATER, WASTE AND VENT PIPING IN ACCORDANCE WITH ALL APPLICABLE CODES. 7. SOIL, WASTE AND VENT PIPING SHALL BE SCHEDULE 40 PVC IN ACCORDANCE WITH ASTM D 2665. PVC PIPE FITTINGS SHALL BE IN ACCORDANCE WITH ASTM D 3311. JOINTS SHALL BE SOLVENT CEMENTED IN ACCORDANCE WITH ASTM D 2855 USING SOLVENT CEMENT IN COMPLIANCE WITH ASTM D 2564. B. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND MOUNTING HEIGHTS OF ALL PLUMBING FIXTURES. 9. ALL PIPING SHALL BE CONCEALED WITHIN THE CEILING SPACE, WALLS AND CHASES AS SHOWN ON PLANS. 10, ALL EXPOSED PIPING AT PLUMBING FIXTURES SHALL BE CHROME PLATED BRASS WITH ESCUTCHEON PLATES AT THE WALL, FLOOR OR CEILING PENETRATIONS. 11. ALL ABOVE SLAB COLD WATER AND HOT WATER PIPING SHALL BE SCHEDULE 40 CPVC IN ACCORDANCE WITH ASTM F 441. PIPE FITTINGS SHALL BE IN ACCORDANCE WITH ASTM F 483. JOINTS SHALL BE SOLVENT CEMENTED IN ACCORDANCE WITH ASTM D 2846 USING SOLVENT CEMENT IN COMPLIANCE WITH ASTM F 493. 12. ALL BELOW SLAB COLD WATER AND HOT WATER PIPING SHALL BE TYPE "K" COPPER. 13. ALL COPPER WATER LINE PENETRATIONS THROUGH WALLS SHALL BE SLEEVED. 14. INSULATE ALL HOT WATER PIPING WITH 3/4" FOAM RUBBER INSULATION (ARMA FLEX). 15. INSULATE ALL EXPOSED PIPES AND SURFACES UNDER ACCESSIBLE LAVATORIES PER ADA 4.19.4 AND ANSI -A117.1. PROVIDE ONE PIECE PROTECTOR WITH FULL ROTATION OPTION CONSISTING OF INTERNAL GROOVE LOCKING RING FOR NON SEPARATION AND EXTERNAL LOCKING RING WITH STAINLESS STEEL SECURITY SCREW TO INSURE EXTRA LONG TERM TAMPER RESISTANCE ANTI MICROBIAL U.V. INHIBITED UNIVERSAL FIT, 3-M DUAL LOCK (TM) FASTENERS SECURED WITH SELF LOCKING APPROVED NYLON STRAPS. FURNISH ONE PIECE VALVE/ANGLE STEP PROTECTOR. ONE PIECE OFFSET PROTECTOR AND ONE PIECE P -TRAP PROTECTOR. PRO-XTREME BY PLUMBEREX. 16. ALL PIPING SHALL BE FIRMLY ANCHORED AND SUPPORTED TO PREVENT SWAY AND VIBRATION THE ENTIRE LENGTH. 17. CONTRACTOR SHALL FURNISH AND INSTALL WATER SHOCK ARRESTORS EQUAL TO ZURN SHOKTROL AS SHOWN ON PLANS AND AS PER MANUFACTURER'S RECOMMENDATIONS, AIR CHAMERS SHALL NOT BE SUBSTITUTED FOR FACTORY FABRICATED WATER SHOCK ARRESTORS. 18. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMER CONNECTIONS AND SHALL BE SUPPLIED FROM AUTOMATIC TRAP PRIMERS CONNECT TO THE NEAREST SINK. RUN 1/4" SOFT COPPER TUBING FROM TRAP PRIMERS TO FLOOR DRAIN TRAP PRIMER CONNECTION. TRAP PRIMERS SHALL BE EQUAL TO ZURN "SANT-GUARD" MODEL Z-1022, 19. FURNISH SUPPLIES WITH STOP VALVES FOR ALL PLUMBING FIXTURES. 20. ALL SHUT-OFF VALVES SHALL BE BALL VALVES. 21. ALL PLUMBING ROOF VENTS SHALL HAVE TAMPER PROOF VENT CAPS. 22. ALL WATER PIPING SHALL BE SLOPED TO DRAIN. 23. ALL SOIL, WASTE, AND VENT PIPING SHALL BE SLOPED 1/4" PER FOOT (2%) FOR PIPES 2 1/2" AND SMALLER AND 1/8" PER FOOT (1%) FOR PIPES 3" AND LARGER, 24, PROVIDE DIELECTRIC UNIONS AT ALL CONNECTIONS OF DISSIMILAR METALS. 25. SEAL ALL PENETRATIONS OF FIRE RATED PARTITIONS WITH FIRE RATED STOPPING MATERIAL, 26, FURNISH AND INSTALL A TIME CLOCK FOR THE WATER HEATER, 27. FURNISH AND INSTALL A TIME CLOCK FOR THE HOT WATER RECIRCULATION PUMP. 28. SET WATER HEATER THERMOSTAT (140' F MIN.) TO PREVENT PROMOTION OF LEGIONELLA. FURNISH TEMPERING MIXING VALVE TO PROVIDE 110'F WATER AT THE PLUMBING FIXTURES, 34. PIPE ALL P&T VALVES FROM `NATER HEATERS TO OUTSIDE OF BUILDING OR HUB DRAIN USING FULL SIZE COPPER PIPING. 35. PROVIDE 12"x12" ACCESS DOORS ON ALL NON -ACCESSIBLE CEILINGS AND WALLS FOR VALVES TRAP PRIMER WATER SUPPLY PIPING TO FREQUENTLY USED FIXTURE 1/2" SOFT COPPER FDS FINISHED FL00 45 T - TRAP PRIMER CONNECTION - -- _ -----... rn TDAD WC -1 WATER CLOSET: FLOOR MOUNTED, FLUSH TANK, SIPHON JET, WATER SAVER 1.6 GPF, ELONGATED, WHITE VITREOUS CHINA WHITE OPEN FRONT SEAT, SUPPLY WITH STOP. AMERICAN STANDARD "NEW CADET" 2174.139. CHURCH #9400KC SEAT. WC -2 HANDICAP WATER CLOSET: FLOOR MOUNTED, FLUSH TANK, SIPHON JET, WATER SAVER 1.6 GPF, ELONGATED, WHITE VITREOUS CHINA, 18" HIGH FOR HANDICAPPED, WHITE OPEN FRONT SEAT, SUPPLY WITH STOP. AMERICAN STANDARD "CADET" 2108,408. CHURCH #9400KC SEAT. ADA APPROVED HANDICAP ACCESSIBLE. UR -1 HANDICAP URINAL: WALL HUNG, TOP SPUD WATER CONSERVING 1.0 GPF,FLUSH VALVE, WASHOUT, WHITE VITREOUS CHINA, FLOOR MOUNTED CARRIER. AMERICAN STANDARD "WASHBROOK" 6501.010. ZURN Z-6003XL-WS1 EXPOSED FLUSH VALVE, ZURN ZR -1222 CARRIER. MOUNT AT ADA APPROVED HANDICAP ACCESSIBLE HEIGHT. L-1 LAVATORY: 20" X 17" OVAL, COUNTER MOUNTED, SELF RIMMING, WHITE VITREOUS CHINA, SINGLE LEVER CENTERSET FAUCET WITH FLAT GRID STRAINER, BRASS P -TRAP, SUPPLIES WITH STOP. AMERICAN STANDARD "AQUALYN" 0476-028 WITH SPEAKMAN S-3561 FAUCET, L-2 HANDICAP LAVATORY: 20" X 18" WALL HUNG, WHITE VITREOUS CHINA, FLOOR MOUNTED CARRIER, SINGLE LEVER CENTERSET FAUCET WITH FLAT GRID STRAINER, BRASS P -TRAP, SUPPLIES WITH STOP. INSULATE HOT WATER AND WASTE PIPING BELOW LAVATORY. AMERICAN STANDARD "LUCERNE" 0355.012, S-3561 FAUCET. CS -1 COUNTER SINK: 17" x 20" SINGLE BOWL, 18 GAUGE TYPE 304 STAINLESS STEEL, COUNTER MOUNTED, SELF RIMMING, SINGLE HANDLE FAUCET WITH GOOSENECK, CRUMB CUP STRAINER, SUPPLIES WITH STOP, BRASS P -TRAP. ELKAY "LUSTERTONE" LR -1720, LKA- 4160 FAUCET, LK -35 STRAINER, T & S BRASS B-1305 SUPPLIES, KOHLER K-9000 P -TRAP. CS -2 KITCHEN SINK: 33" X 22" DOUBLE BOWL, 18 GAUGE TYPE 304 STAINLESS STEEL, COUNTER MOUNTED, SELF RIMMING, DUAL HANDLE FAUCET WITH SWING SPOUT AND SPRAY, CRUMB CUP STRAINERS, SUPPLY WITH STOP, BRASS P -TRAP. ELKAY "LUSTERTONE" LR -3322, LK -4161 FAUCET, LK -35 STRAINERS, T & S BRASS B-1305 SUPPLIES, KOHLER K-9000 P -TRAP. DISPOSER: SINK MOUNTED, STAINLESS STEEL IMPELLERS AND GRIND COMPONENTS, INSULATED, 1/2 HP 1725 RPM, 115 VOLT, 1 PHASE, 60 CYCLE. ELKAY CENTURY LKD-100. EWC-1 ELECTRIC WATER COOLER: WALL HUNG, HI -LOW, HANDICAP ACCESSIBLE, STAINLESS STEEL, FRONT AND SIDE PUSH BARS, SUPPLY WITH STOP, BRASS P -TRAP, 8.0 GPH OF 50 DEGREE WATER, 1/5 HP COMPRESSOR, 5.4 FLA 115V, 1 PHASE, 60 CYCLE. HALSEY TAYLOR HAC88L-Q. FD -1 FLOOR DRAIN: CAST IRON BODY WITH BOTTOM OUTLET, COMBINATION INVERTABLE MEMBRANE CLAMP, ADJUSTABLE TYPE B NICKEL BRONZE STRAINER, TRAP PRIMER CONNECTION, ZURN Z- 415 -P. HD-1 HUB DRAIN: CAST IRON BODY WITH INTEGRAL TRAP, BOTTOM OUTLET, COMBINATION INVERTABLE MEMBRANE CLAMP, ADJUSTABLE TYPE E NICKEL BRONZE STRAINER WITH 4" FUNNEL, TRAP PRIMER CONNECTION, ZURN Z -450-7E OR CAST IRON HUB WITH DEEP SEAL TRAP. SS -1 SERVICE SINK: WALL HUNG, 22" X 20" WHITE VITREOUS CHINA, CAST IRON S TRAP TO FLOOR, STAINLESS STEEL FRONT & SIDE RIM GUARDS, 8" CENTERS, WALL HANGER, DUAL HANDLE BRASS FAUCET WITH SILVER SPOUT. SUPPLIES WITH STOP. VACUUM BREAKER. ELJER MODEL 241-0354 SINK WITH 4491200 FAUCET. TMV-1 THERMOSTATIC MIXING VALVE: WATER MIXING VALVE WITH MINIMUM FLOW OF 1.0 GPM, MAXIMUM FLOW OF 1D GPM, ADJUSTABLE HIGH TEMPERATURE LIMIT STOP, INLET CHECK STOP, AND LOCKING TEMPERATURE REGULATOR, MANUFACTURER TO FURNISH WALL MOUNTING BRACLET. 3/4" INLETS, 3/4" OUTLET. LEONARD MODEL TM -25 -E -RF -LTR. PROVIDE DIAL TYPE THERMOMETER ON OUTLET PIPING. ® WATER ARRESTOR EQUAL TO ZURN SHOCKTROL MODEL Z-1700, 65 T PSI MAX. RATING MAX. PIPING LENGTH COVERED BY ONE ARRESTOR. SHALL BE 20 LINEAR FT. TYPE "A" = 11 FU MAX, TYPE "B" = 30 FU MAX, TYPE "C" = 60 FU MAX. ALL WATER ARRESTORS SHALL BE TYPE "A" UNLESS OTHERWISE SHOWN. WCO WALL CLEANOUTS: EQUAL TO: FINISHED AREAS ZURN, ZN-1460-2VP 8X8 UNFINISHED AREAS ZURN, ZN-1460-9VP 7" FCO FLOOR CLEANOUTS: EQUAL TO: FINISHED AREAS ZURN, ZN-24000-2 CARPETED AREAS ZURN, ZN-14000-14 UNFINISHED AREAS ZURN, ZN-1420-27 ALL THREADED D^^ STANDAR ALL THREADED ROD HANGER PIPE RING 69, TYPE (FOR 1/2" THROUGH 4" PIPE ONLY) SUPPOR- STEEL B C -CLAMP THI THREAD ROD TOP BEAN Lj--- C -CLAMP NOTE: 1. PROVIDE PROTECTION SHIELD FOR INSULATED PIPES 2. SIZE RODS AS PER TABLE 13-4 ASPE CHAPTER 13 3. SELECT SUPPORTS AND HANGERS TO COMPLY WITH ASPE CHAPTER 13 CENTER -BEAM UT IUGH Y) 1 BEAM © Copyright 2004 ACi, Inc. 3UMAN SERVICES ASSOCIATES, INC C� S COMMUNITY BASE CARE SEMINOLE Sanford Florida I Acz ASSOCIEIMD CONS UI.TiNG IN`I'ERNATIUNAL DEVELOP NIENT. DIIINAGFAIENT. ARCHITECTURE FL AA0002940 955 N. PENNSYLVi-NIA AVE. %SINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FA_X: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI. Inc. any unauthorized use, dis- closure, dissemination, or duplication of any of the informatlon contained herein may result in liability under applicable laws. Issues and Revisions JNo. Date Issue/Revision flr i 02/23/05 VE / REVISION Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416.dwg Phase: PERMIT DOCUME1\1T Sheet Name: LEGEND & NOTES PLUMBING SHEET NUAB3ER • FM 13 BOBES ASSOCIATES CONSULTING ENGINEERS 150 CIRCLE DRIVE MAITLAND, FL 32751 407.628.0882 FAX: 407.628.7024 C®.VOICE: E-MAIL: INFOOBOBESENG.COM FLORIDA STATE P.E. NUMBER: 5131 Issues and Revisions JNo. Date Issue/Revision flr i 02/23/05 VE / REVISION Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416.dwg Phase: PERMIT DOCUME1\1T Sheet Name: LEGEND & NOTES PLUMBING SHEET NUAB3ER • 91 0 3-1It N 0 N af K i N M 2 D 0 It .14ID I') KL 1 EXISTINGTOANITARY REMAIN ESTIMATED PIPE INVERT EXISTING UNDERGROUND -43.5" BELOW FINISHED FLOOR ! € €--I - - SANITARY TO REMAIN . �I- _i l l=, - 5-o I I 1 € I�I ;- I s I EXIST. ELEC. WATER HEATER EWH 1 2 J - --- - - --- - - - - - - -- -- _ - - --- -- - _... , _ _ _ _ _ -.�_ I = I :EXIST. -r - _ I °' 11 I - £ - - - -i _-- I [, I f x _ - fr,p I _ _ I 1 �_ I�IECH- I i I' I S 1 1PiNG-'� - ��ATE R HSA I I I-II. 1; - \ I I „""-_.�>_ .; =-I- I �{ �. § :'_x.1 = _ _ :Ir=' -a l_ ?lam II - €'-+ ;-_ €- { I far• --'I f i_( ! E I I< ---� s tri Imo= I` _ _ - 1 - i i I ,,;, r € € _ € _,€ _ - EXIST. FD _ I I sa��-�... ; _ _ - F 3 c _ I - z , .' i , =,a T 3 ) sem`' J _ 1 fzs x T n _ I ; _ , __ 1 I ` - I EXIST. LAV EXIST. SS : - E - 1 /2" { n - I i z� I EXIST. LA 1 I I 3 " _ - I '{ r W W 1 "' I i I. - r ,_ 1 I z - i _ s ° ' I , , . , € ; -]- _ _ _ , _ `-Ni f __ I zs > 9-_ l � at , !I; I ---- - r I f'I, t; It ° 1 �, A _0 I i NEW TMV-1 I I i I 1 I 11' : EXIST. WC 4 „ 1° V I I I it - ti 11 j A , ' A ' I I 112 I Y 1 I} I I I I t 1 I O ! I I{ _ _T I I` _, I If {1. Ij Ii I I I - --�-- II , € 1 - 3 I € ;�I-' 1 I { € 1 _ I 11 I I , - - = s, s I _ .: _ - < - _ I _ z T"° z 3 _ 3 � _ -__ I >_ _ a F� '�I:T'-i a Ir,�y - F = - P, = i} = _ _ , _ , 3 I _ - 3 J .� - _ _ I - - i� }' - - t I - � - � r - as �,. - l I € #. :> I J..,. II =�1­ 1 I _ I 4" I I .. 0:�c 1 �t _,a -U 'itI I I - _ -;II . _ _ - --- - - # I > _, - r , , II } I 1 I I =='-_ _ a _- I - _ I - - a - -- ,, _ _ _ �'- -.a _€ I - - a, ;_ I I< _ I -1_I F :I - I g I r If I I I§ ; _ r ,> 3 , F 4, r g r I _.� � I= I I I i r, I-� - -- - _3 S r _ , = r _ I _ _ _ .t _ _ , t, __ __ _ _ ii � 1 [[ ; t... � rte# _I' £ I€ I :l H Sk& I rI r _ I ?' _ _ _ I€ 1=.d 7 t" ;1 I j• _;,L�,I, #I P #F1 - - I __ __ . - j I 1 1 !€ €. ii,o. I I I I I l 1. I'=1 r - 1 I , I I xl I is I I r� II , 3I `_ _- it I I _- - ��- "'a I ) 3 3 1 , I {= -�j� - - - - - - - - - - - - --- - - - - I` 1. IT t I t I t 1 1€ ' - 11 _. I I € 11_ I I ;, 10 1- 1=1 #s# 1 I , ; ? RUN CW PIPING AS HIGH AS POSSIBLE 11 `' I 11� I I ! ., _ _ - 1-- -= ELOW=ROOF==S ORT STURCT 3 j I _�' P' 1_ -- t �I _ - It ;I�� =z __ = -1; I ! I €_T. ! �€�_ R =P 1 I � I, I I = r 11 - _ 'I r:_ I - �; r _ HC- U P _ U I = r`,: 1 _ I _ ii I B ;jl ;. i €I M. r=`r,1 IE-L- .: '•;_ II: I €I s` Tt _' `S i - cl �i I tI - II ,; <, - - I T;� , - I li =1s-;.; I€; �>R II , v.'_IJ �: �i1_.. - -- ,_ I_ II FCO II I I I § I I 1 IIj hr I � # ,I I` I , €_{ X13 Ii I= € I€ _ 1_ - v t 1 I T L €Ja 11I Ili %I- , ,I- jj x I § I = Fir rl � ; I ;I ,§t IT - _- € - - - - -- __ € I -`_ s- - Ii _ _ 7 € ; ,�_TT I II ),> - -- I; ,�,»>=s _ .._ -- �='__- I - ---- i€ I£ I _rr € - I € 1 -., ) .-,>'- it' i �'.£s', 1, i ..T� >' I, 1s..,] I 11 z I£#"' 3 -�>-3� '>I -.It I ).�_� I _ I _ ;j l..§I>r�„�' )€ �1 {I3;1 I I. _i .,r1' x #xI, €I• I= _ I ; .- -_ i -_ 11 j ! Il .I lir--}E�I -171 „ a i--!" §g� ., € �IF !-<r}-i1� s-, II -I s�� I' �` ' '_'' � II I_ - , _ . § :_ I 11 I t I: __. j1 •;7'-�` # . r'>i x ;': DL , I, a s 3': :3 r'r1��1 ; Nit P, U s- • j _ =rte €I } - I = 3 € _ € , IIS i j, Y;r II ' i ;I = 1; I -_ 1 Y s 1 I I - € - 'T-� 1; - �-,- II , - I I I 1 1 II s , -- - - - II I t '1 I 3' 1 tI I 1{ _ __ {I I }I x II I a i „ . is I _ c ; 's I I ,, - I 11 I - P - -' 3 r-3 = _ - - .I a i t ,35 I,�' `- E Z; ' ! , 3 _si __ .zi �r x,13 ;-i _ , I I€ I - - -_ e1 Ips -> i;a III - I L � 11 = I _ _VII� , r; , I = I° _ t - II I •I I ;{ IIi, I -,; ; }_. �€ _ �= iI II - - I - - - -I I _ I I€ I ..:I '} e _'="}: ' 3€ £ - -_ € € 1=�3 - i 7 i I __ _ _ __ -_ _ --__ - , _ 801 -sal:__ It i r§ I II T # I i 11. s 1= I�€I AR Mon 1' ' piioc) _ ,,, 1f -', 0 �I ,Ii r#1�� _ „ _ �R � tJ _ _ , jj rI r I r 1 P t £ I €� €-i ? €':3 T E a II i"t� ,.. _ I iI € i; €r I = - . _ - I°yP I ,I �, _ I - :I I __ _ - . I _ I I I E I H= I'�,r I° I SOI I al ff° 1 1» _71[ I I I II 1 i1 I I 1 I ; _- __ -- - -.. ____ _ -__-- s - _ a1p - '' 4§ I i�A) r (tt II aC :S 1 >r'_ =i I€ - �'�. 1 I } iI i _ -} _.� = Ij'#I )I _, - _> s i II J v> --fix ; ;.:r.'-€ ,, . i > : _ I; a,= t-� I'I 13 € s I 3 > ._-..�- -- __ __- _ > . I; _ n �I T �_ I - : -_ -II }} 1qq xj? _ _fr I: I tl', IIT11 -_ 31fJr 31� Ic 3 r�E i I` §: } Ii = a) _ i.FI .3:43_ -> , t M _LA 5 €i§ -}_- > } _d.3 - }_� - _V ,; --� II I , 1 '(3-� - II i#'.} I I fr 1V, I i � i I it -r� j�1 � 11 � I t� �F,� = / �� If i atz It I' r� i i %.`.i: t'_ r I r 8....-: �€'_ I � HS7 o 11 I i, '` l - n-= -1 ,o r- n,� 1� I I II I I° �I s,r € I I _ f-�: I WIS_` I € 111 - � --/"--- _ - _ - --�- - - - - - - - -I - T_ - 1� -_-- - _ - - - -- : _ 7 ;_ I; .;-_�TI01 r ____ _ I€I �- -I ;I,I I' I I - i III I` I , € � I �� il 1� 3 1 1 x g I 'ri�I I: I1 € Y j P - _ I € = s�I�i }L_`, - I �. _€-, � ES I If ; I � I; �� I CORI ,-r R .13 I I �C II -t T _ I -- - -- - I - - �, 1� = I 1= I€ , - = _ I'} II II I I 'r I I0 I, - - - I- §I I n , z - t 1 i I I 3 ,, € { ,s I = = I r-= 'l ,I }{j( On u[ iii I ;, F -€tY I€ r�r S>'; 1 ^} _ I z i i `L_ a _ �� I I 3 -,,I _,I . Ia I{_ ;- I;€ € _ rr-' �1 I r- I t} t: } It.= ,>.� a ail, III -I,__ t la I �_� - - { 1 I II` i II I �� Iz€ - :# II �� = vl = I t _ j 3 -- = - d ' i '._' szimj €I , I F. ' ? I I '' Ii..,. {<f (I� `'r _ - - t I _. '-�_ I § _ 1 I r1;Ir=_ ,_ f IN�., ��---- :, I I I S--- ( 1 132 _ - I'S�1 31 ;IS IFI I n I I 3 F ,3 1 ° II r t 1- I=( I I _ I' I I z`=t` E -- t -'F ir` '} I W I I t ` ,� 10,: II II I- �' Iii i € �� I I' _ �'� i }} = I � � ��' � I III vriDa a# I = , jjj - 411 I, _ a_ _ �{A § € I- - i�. € U! =, t't � zAR U€, ,f '- _r IV i -I I_ - __ ,...,.,<,v,..._. I _ I �I 3� Pilo �_ f�ll� 11 ��r -I[ _ I IAr� I- I (t1 ll OFrI FE - ,- I� _D - III I_ 7r`�' t t 1 I I 0 io? � I __ I ` III III - _T� i � I 1 I I - I ' I= € € I I I EI I rI 1 �11 ���� } It 1� I I: 3I rIJ . €I - r Ix II x I , =I , . TFFI x'05 I s 1 ISE �' 06 I 1! HRNR__ ,; II__ v*: I.1 "I' I -3= NF R_==ICE 1 1 M0 Uri ii n .' _ }, I = s _. _ - -- 1 i II- € _` _ ; _ R€" t 33Yi "3' lI3r"-.i { t''I ai _ _ _< _� _ .- II 1 €- _ i,I-§>„ _- r1€ -T __ .`7-'] t j_j=m i - € I I II) I >y D II, _ I 7; ,i€;' : ;;SII a' 1 E4,_E I € 129. 1 l", Ir .� t ' , I£ - I II 11 '`�I � _ #} j T 1 t= _ #0I �> fir 1r '� � I z3� �,� £;t € �� � _1? �` - --- I �II I _ - a> I --- i I I I - -- if - -= HRI� �- =; -.�_. 01 - I '.-. = I ; I I L `� € > i _EST j } P H# -. I--_ .� �' i d � � r� - I t If I I =, I i a ; '... I COr' - :T _ iI - - - - - - _ _ - {, - 3, - I �>~ - til = �€ _ I - - -- - - - - - - - - - -"' 411 - - - - - , �I -_ _ _ - I I �( I 1 { __ T 'E I € , r �_ , _ I a - I _ v i I �I I I � a- i__ - [I { I 1 - I F03�Er -_- ') I z I- - _.- _ ' t ��ON R, r - ' § 4€t VTR r = = I C _ , I I - I1; z RO M ,:- I I = �-, �+ `I --. s t I }ter t= -t=- t I f ��t I I € �I- - 12„ I - -� € I, I INTI✓ Vll��d , VI ON II li1T�r�'/Ir I+ `I �I �t, 1 I rs I € I:I 11 _ II �: I - �, :1 I - I I I , = I- I M Ix1TA? H tI 11 _ ?•' ENC -1 I i 1 = _ R0 I , € D I I M>?I =: IILf'H '_ i.i -_- �CS'1 I r OIr1 It _yt I , I I ` ] 1 1 =fes I 1 _fir I I'I = � -= - 2»FOIS1 II I 2 FCO I , I. rAw n 1 _ _ - }J I I 11 t I 1 I I I I,DUI, R I _ �'d.D WC -€'11 _ I _ _ALi ,. I s I;,t I,lij , _ I �_ {; „ `� « . , 4 F I UR 1- V_ ,n_I { I I= § --. .I _ , / _ OR _ r _ 511 �_ `__rjI _ .ra1 �"T' _ _ I -- - -- - - - - Y {I CORRIDOR j I '111 ice. _§ --- 1WGO I 1# I I I I ,; 1 4 ; I If;I I- _ - - } -= II , I I I > _ - _ --. ..__=-z�> I - ___.a_ -it j € a - ,Ir,,T; 71 1 2 f e s< I£r'I'r4 ) I . --7 �11 ' _ _ _ _ _ __ I I I _. - __ _ T----__- ate_- i' I I €€i_tt tF-2.. rir ,ter -z V PEI -I_ In I - I p }5-' _ I , - _ __ -..I I I I � l 1 II I- II 13�ODUt - I�� MOMQLAI II: I �,3 _; €. � I I.3 FD 1;I I ., - - �€ 42}€ II 'II - - € i - - ;? I_ III it =_ 11 I.._ I - _ _ IT�1f. tj rr I€ I I I I t; 7t €€ iI i E a ( I I 1�)'IrEr rf Ir I 1 I c III I; - L_2 . WC -2 F 4- NC 2 L- 1 � FI� n I ! [[ 1. ROOM ,:Tray I 'I� :� !It It =�-_I.I _-- -I -- ----I1 I - - - - l: q I } -- _€ _ 1 , ° 1, 2 VTR IIr C8CS I - € € I € § _ /-b I - I _€ _ - I I _ � 1 _ Z. 3/4 I - I ROOM i`•a - t . FGD tj __ i 1 III I i I I'� I� 3 4 II MI NTA1r 4"Ii=SAI r+�TH /// I ---- - ;, - jlll _ t , >- a. I 1 � �= Ir I a 0DU� -'� €ISI `>R '-a V_1 _..._..... 11 _ ._ £ I =� _�..._�.,1 € it n -I -I ` '}T -€- s-?1� III �Ir Yi'. t' V_ - z -f'„''€'>'1, _ a = I % a 1 ; I I =' Y I _ I� ,�- - --- _.-_----------._ -- ---- --. _z -'s. t r„ I I I i I - -- fid I� ` €i 3`C sC-.f'!i -fir; 3 !F� I - I II I f-- ___1 - - I -,I _ 1 = -- --- - =I '' i I -1 „ ;i; 3 ,- ;r'- �I.�'._ 1`I `'� Ii '_ I r_ -3 __ �-,� t I I I 4 :I : . 1 / I I 1 I Ir= r _ _L__; '� 3 If = m .1 f€rx 3;r=, € a T _ € 1 jj ; I - � €_- := „ 1 �7r., _=, 7�_ _�j :t �'F"`^� II -rte- ''§I nl i.:L.I i.�. f.��I ', '�' 1-11.1 €2i I --€�,:t' _ _ s�=<>s __ _ , I'._ -/I =' _ ` tee- I `I x`11 , 4 I 1=3 I _ ;� I - I J _ _ --- !I _ -_ �, _ _ - =_C�l�n}3_ -_ FU LAN€. ��� � I III 3 ; ° 1 _ - --��- - -� - -�� O- Tt I -_ - t - 11 _ a I _ _; J - -- •I i ; - / _ _ -- -- _ - = _ - I1 -- 3, / ,I =� _ - -- - - - - - - - - - _ - _ _ _ _ - ;> t 21, I- - 1 / I II € I I I 1 Y�CO I / spa 111 - I ' I_ § I �� I I I € i -= I _ L' 2 ;I�v 1 ' F_ I 1 t , -- , I = I - -- / d0 - - �,-°- = - F "� I : t I]J ='•�� -'�.-i €� - r_ 1 I I:1 ,a;,I , =` i' I';^ i , -,r--=-i �- 1 , 117--r§111I AM II / i = - __ __ ____ a{,7�-� _ > I'.=;��= I_ m; t'�-f-,-= I I r , �; FI I, t FIs-§ - I IIl I• -q i 'r I= 1 2 I 'I {'-• 3''z ° ,?j T' - I I - _ - I I . 13 _ { ___ �_ ! ` I I I - 3 - ....� -.- - I = I, It 1 r 'r; /- _ €�_ I iI I� ,s r I = I I / �.� II - � . _ I, t 41 I- £ _ - &_:_________J 3 t rj I _.= I I I.Ti=j�I�=: II I b� ;t ;__ II0 I---- - I1 I =I - ��RR1DI} `�2, / i= € -�l F t=� I.. II, I -I I i ____- ;I __ �� €1 , n _ - . r ±mss' _ € i A A A � I i ,Bt�y-� I r FI 11 I i' ,I. _ Y- - - ; }3t _ _ �i I- paw - �r - II ; II _ I I ' I - �_ �_.. __--- ,� 7 - - - - I - I �_ / � 3 � - � I 7 r , 13 _ I R__ � ___ I I I i 1 I � j I F,r'). -I 1I I I 1 a., I I 11 I I I i �` I r � ? I€ - 3 ; $i=l a"r=' °€ €' - I_I} , '1I; a li-'r _ III [ I _- .... _ - I I - 1��_ 111 _ _,�- /I I�. 1: I __ , € _ € _ _ E I 1 c0� r I € .-. ,_� / 1 - =IU- I }t It I I-_ ?t 1 0 = I ! �� I I i , - d - - • I I�-� = I , , 3"'"' ' I - ---- I I -1 -- I ` I _� - - ' I r _ I � I I: I 11` 71 F€ r- € / / I; 1 1 1-I I I!1 y It I i 1 i l: I 13 / ;I 1 I I ; - ;I I; 1 ' = - II 1 _ _.. -x 1 I 1 €� f t I€ , , s 1 c E s t 1 -,....<R ,<....-.�.,.� -- , t t<d t I - -� I I r I _- 1 _ - _'I C' -'=Y I € I - t- I { / :F I I I I ; I - EAST/ 7s I I r = S - - - _ �1 -_- I _ I I I . ' f �. • � I I = a a Cy LU � � _ _= Imo ---I I I I § x i , ; 1_ "I I I ;, ti _ II 11 I I 3 I t } { „ �'_ €" - € i a F ;�} ; I i ! - € € 1 >ii 11 _ I I = _ - -it I II I „ € / I I I _##r I's=1 r-rr {€ _ __ I Of - f-;- 1„7= II` �� it Il: WCO -_` § I I - I _ It Irl1� 1 i I =1 I 114 1 P3 _; 1 _--� =iT I _ } 4 `I = 19 _= I , I CS -1 ; ; 1 I tea' }j 77 I , _ ._. I .. __ _-__ - -- __. _ - ; - - _ { _ r - - -- _ - - - -- - -- - _ _ s€ Ii I I II II I I I I I -I iii- - I I r_1 __ I I I i Iii _ '� s t 1 1 I I I I- '- ° ---i I =I I I II II I I II 11 = I � . __ _ I I sr. v __> --_, _e �_ _a _� _- _. � �-. � ___ --._ tea. _. �_ � _. -__ - >_� _, .� � _� _... �u -� � _, - �� _> �_ _� � � � - a _�_- - IE�'' �_, �_2 � _. �>_, �, ------ __ . -= -- II I I I I - FLOOR PIAN - LIGHTINGI I SCALE: 1/8"=V-0" T� a I i-1 I11 i �� I-; I T_ I a I I _ I tEi : p 3 Y t3 A IR D > I IE R -__-----r ------ _. ..- ------------y --- ._._ r 1 11 -i --_ . _ €-__. - -a _ _._�- - - -- T _ - .I' _1 € I I I I I p I I - -r._ I - , i F j{ { [ _ I T 1 _ it ,t _ _ _ _ _ I gg ( j -1 I 1 i1 1 I. ' I -1 {-- TS - r3 3 II, €- r__ � I � # # '_ _ __ _ I _�- 1 - I ! r r I , - I I I_ -1r - IIg �; I r 1- - I Iv a ' I 1 I i I 1 I �� -=l 1 .-.L,11 I __ - {01 1 r i '1U F 5%A 3 tT�� t r �, 1 r �1fw _ � _ I� I __, _ ' - x - I - - 1 € all - 3 I -§ t � -W'- - _ I < _ _ I #, , € t I T3 I t1 E LTH F f' -LES I - _, i3 m I 3 ; , z t - _ ........__ - ----_ ..._....... ___ ----- ,....-_._.-..-.. --_� _ ---_ - __ -_ ___ _ a- -- I- __ _ C -1 :al mss. E. I I > --sr: - � _ .�`r RCI' - r''at.::': I _� FGu i �I 206 - - I ! I It _ 1 ---- -�, t = I I € €I I - - I q4j I II - 9 e ,,. { sea - €' "c `F I ;" ; r .Y ; ( _ A; _ _ € _ - I _ _ - - ; r i - 3 i, ��ITT � i� I €..r m J€ t' P' € €§7€ >_�__ I'>I=,--- - `r;�},- I ice' - I,3: _ °� ->�€ s'I�a? ­ i'� _ I -_ .i ` ROOM �, � � _-_ ,€ �- _ ,{ .a �, ; s tri 1 I , T I€ #€ I 05 ! €# IF t; I I f. I! II 3 1 ', j f� It - HEX NOTES O NEW 4" SANITARY RUN UNDERGROUND CONNECT TO EXISTING SANITARY OUTSIDE OF BUILDING. CONTRACTOR SHALL LOCATE EXISTING SANITARY MAIN ON SITE AND DETERMINE THE PIPE INVERT. SAV'! CUT AND PATCH EXISTING FLOOR AS REQUIRED TO INSTALL NEW SANITARY PIPING. O NEW THERMOSTATIC MIXING VALVE CONNECT TO EXISTING HOT WATER SUPPLY PIPING. CONNECT OUTLET OF MIXING VALVE TO EXISTING HOT WATER SUPPLY PIPING TO LAVATORIES. ALSO CONNECT TEMPERED WATER TO NEW SINK CS -2. CONNECT EXISTING COLD WATER SUPPLY TO MIXING VALVE. O EXISTING FLOOR DRAIN TO BE RAISED UP TO BE FLUSH TO FINISHED FLOOR. U4 NEW 1 1/4" DOMESTIC COLD WATER CONNECT TO EXISTING COLD WATER MAIN INSIDE OF BUILDING, CONTRACTOR TO CONFIRM EXACT LOCATION OF INCOMING WATER SUPPLY. O5 EXISTING SANITARY PIPING RUN UNDERGROUND FROM REMOVED PLUMBING FIXTURES TO BE ABANDONED IN PLACE. O EXISTING DOMESTIC COLD WATER PIPING ABOVE CEILING FROM REMOVED PLUMBING FIXTURES TO BE ABANDONED IN PLACE. CONTRACTOR OPTION TO REMOVE PIPING BACK TO CONNECTION AT WATER MAIN. 7 NEW 1 1/2" VENT RUN ABOVE CEILING AND CONNECT TO EXISTING VTR FROM EXISTING PLUMBING FIXTURES. A" PLUMBING FIXTURE DEMAND SCHEDULE SYMBOL DESCRIPTION QUANTffY DFU TOTAL CWFU TOTAL HWFU TOTAL WC -1 WATER CLOSET 1 4 4 5 . 5 --- --- WC-2 WATER CLOSET 3 4 12 5 15 --- --- UR-1 URINAL 1 4 4 5 5 --- --- L-1 LAVATORY 2 1 2 1.5 3 1.5 3 L-2 HANDICAP LAVATORY 3 1 3 1.5 4.5 1.5 4.5 EWC-1 ELECTRIC WATER COOLER 1 .5 .5 .25 .25 --- --- CS-1 COUNTERTOP SINK 3 2 6 1,5 4.5 1.5 4>5 FD -1 FLOOR DRAIN 3 2 6 --- --- --- --- HD-1 HUB DRAIN 1 2 2 --- --- --- --- TOTAL --- --- 39.5 --- 37.25 --- 12 WC WATER CLOSET (EXISTING) 2 4 8 5 10 --- --- LAV LAVATORY (EXISTING) 2 1 2 1.5 3 1.5 3 SS SERVICE SINK (EXISTING) 1 3 3 2.25 2.25 2.25 2.25 TOTAL* --- --- 13 --- 15.25 --- 5.25 FD FLOOR DRAIN (EXISTING) 1 2 2 --- --- --- --- --- DISHWASHER 1 2 2 --- --- 1.4 1=4 CS -2 COUNTERTOP SINK 1 2 2 1.5 1.5 1.5 1.5 TOTAL --- --- 6 --- 1.5+ --- 2,9+ BASED ON 2001 PLUMBING CODE WITH 2002 & 2003 REVISIONS: TABLE 710.1 AT 1/8 PER FOOT SLOPE (1%) FOR 39.5 DFU REQUIRES 4 SANITARY MAIN= COLD WATER DEMAND FOR 37.25 CWFU IS 25.5 GPM, FROM FIGURE E1038 AT 1 1/4" PIPE 5.0 FPS AND PRESSURE DROP OF 4.0 PSI PER 100 FEET. HOT WATER DEMAND FOR 12 HWFU IS 16 GPM, FROM FIGURE E1038 AT 111 PIPE 5.5 FPS AND PRESSURE DROP OF 7,0 PSI PER 100 FEET. * EXISTING SANITARY PIPE SIZE SHOULD BE 3". BASED ON TOTAL OF 54 CWFU EXISTING MAIN COLD VyATER SUPPLY FOR 30.3 GPM AT 1 1/2" PIPE, 4.9 FPS AND PRESSURE DROP OF 3.1 PSI PER 100 FEET. +COLD HOT WATER FOR NEW COUNTERTOP SINK AND DISHWASHER SHALL COME FROM EXISTING COLD WATER SUPPLY AND EXISTING ELECTRIC HOT WATER HEATER EWH-1. © Copyright 2004 ACi, Inc. I HSA HUMAN SERVICES ASSOCIATES, INC. lc:� C�� COMMUNITY BASE CARE SEMINOLE Sanford, Florida AC i AS S O CIATE;D CONSULTING INTERNATIONAL DEVELOP.ME T.KNNAGENIENT.ARCHITEC N TURE FL AA0002940 955 N. PENNSYLVANIA AVE. f lX INTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX:407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted Py�9 material information belongingexclusiwxl Y to ACI Inc. Any uncutharized use dis- closure dissemination or duplication of any of the information contained herein may result in liability under applicable laws. ��Xil ^ / ✓ - V Issues and Revisions No. Date Issue/Revision By 02/23/05 VE / REVISION ABJr Date: BO®ES ASSOCIATES 11:031 CONSULTING ENGINEERS Drawn By: 150 CIRCLE DRIVE MAITLAND, FL 32751 407.628.0882 FAX: 407.628.7024 ®VOICE: E E-MAIL: INFO®BOBESENG.COM File Name: FLORIDA STATE P.E. NUMBER: 5131 ��Xil ^ / ✓ - V Issues and Revisions No. Date Issue/Revision By 02/23/05 VE / REVISION ABJr Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416=dwg Phase: PERMIT DOCUMENT Sheet Name: FIRST FLOOR & MEZZANINE PLANS - PLUMBING SHEET NUNIBER P-1.1 L NEW 1 1/2" VENT RUN TO EXISITNG VTR FROM EXISITNG PLUMBING FIXTURES 3" \ EXIST. FED 1 DISPOSAL 1 1/2" C`• �. EXISTING COLD & HOT WATER PIPING TO EXISTNG RESTROOMS AND SERVICE SINK J)ANIIHKf MHIIV VUIJIVc. Ur OUILUIIVV / I \ I 1 1/2" EWC-1 WCO 1 / 2" / / "1 // 1 1/2 — //- UR -11_ � 1 1/2„ 2»� I \\ / I LL2 I WC 1 \ / \ n t>6 XWC \ /D-14" 4»/ 2" / 3" FD -1 L-2 4„ 2 3 2" WC -2 I 3 / / / LL1 I �3" F WC -2 D-1 L-2 1 1/2" 'a-r-ANITARY WASTEAND VENT RISER DIAGPWA g NOT TO SCALE THERMOSTATIC MIXING 1/2" VALVE TMV-1 \ . 3/4" G DOMESTIC COLD WATER © Copyright 2004 ACi, Inc. ' HSA HUMAN SERVICES ASSOCIATES, INC. CD 41�0� S COMMUNITY BASE CARE SEMINOLE Sanford, Florida Ac i ASS O CIA -MD CONSULTING IN'I'ERNA'FIONAL DEVELO P-NIENT. jNtf1N AGEAiENT•ARCHITECTi; RE f! AA,0002940 955 N. PENNSYLVANIA AVE. \VINTER PARK, FLORIDA 32789 USA PHONE: (407) 740-8405 FAX: (407) 740-8406 COPYRIGHT NOTICE This document contains copyrighted material information belonging exclusively to ACI, Inc. Any unauthorized use, dis— closure, dissemination, or duplication of any of the information contained herein may result in liability under applicable laws. Issues and Revisions A ❑ BOBES ASSOCIATES® CONSULTING ENGINEERS Issue/Revision By 150 CIRCLE DRIVE MAITLAND, FL 32751 407.628.0882 FAX: 02/23/05 VE / REVISION ®VOICE: FLORIDA STATE P.E.SNUMBER: 5138.7024 Issues and Revisions No. Date Issue/Revision By 02/23/05 VE / REVISION ABJr Date: November 30, 2004 Checked By: Drawn By: Project No.: 0416 File Name: _2010416.dmg Phase: PERMIT DOCUNIENT Sheet Name: RISER DIAGRAMS PLUMBING SHEET NUMBER P-201