Loading...
1401 W Seminole Blvd - E05-003915 (CENTRAL FLA REGIONAL HOSP.) (ADD UTILITY SWITCH (A)REVISIONS PERMIT # 2— IS ADDRESS RECEIVED �r JAN 0 4 2007 DATE_T��� CONTRACTOR l 1 PH # FAX # DESCPRITION OF REVISION: 'OW\ ANZ& &-10tr-Ad - t Crvk-%,t UTILITIES FIRE BLDG � ,•a, � 5tv7' cA3 NEC TABLE 110.26(A)(1) WORKING SPACES NOMINAL MINIMUM CLEAR DISTANCE VOLTAGE TO GROUND CONDITION 1 CONDITION 2 CONDITION 3 0-150 3 FT 3 FT 3 FT 151-600 3 FT 3 1/2 FT 4 FT Note: Where the conditions are as follows: Condition 1 - Exposed live parts on one side and no live or grounded parts on the other side of the working space, or exposed live parts on both sides effectively guarded by suitable wood or other insulating materials. Insulated wire or insulated busbars operating at not over 300 wits to ground shall not be considered live parts. Condition 2 - Exposed live parts on one side and grounded parts on the other side. Concrete, brick, or file walls shall be considered as grounded. Condition 3 - Exposed live parts on both sides of the work space (not guarded as provided in Condition 1) with the operator in between. NOTE NO PLUMBING PIPING SHALL BE ROUTED THRU OR ABOVE AN ELECTRICAL ROOM, CEILING ELEC. PANEL OR DEVICE FINISHED FLOOR MINIMUM FRONT VIEW ELEC, PANEL FOOTPRINT TO STRUCTURE OR 25'-0' 6'-4' SEE TABLE SIDE VIEW ELECTRICAL CLEARANCE FINISHED GRADE iu %-I "i D I T P RTS r Cutler -Hammer PRLC Switchboard manufactured to switchboard standards UL 891, 2000A, 480t277V, 3PH, 4W, 65kMC rated and consisting of Cutler -Hammer Model CRD, 100% rated, 2000A, Molded Case Circusf Breaker with Cutler -Hammer Model Digitrip 510 LSI trip unit, and Key Interlocked with Normal Power Disconnect Cutler -Hammer Emergency Generator Quick Connection Assembly, manufactured to PRLC switchboard standards UL 891, 2000A, Nem 31t, 480/277V„ JPH, 4W, 65kAIC rated, and consisting of 2000A Hubble Generator Incoming Power Quick Connect Receptacles, 2000A Density Rated Copper Bus, and a 100% rated, 2000A, Pringle Type QA Non -Fused Bolted Pressure Switch Generator Disconnect INCOMING 480/211 VOLT SERVICE 4000 AMP UTILITY ISOLATION SWITCH L� ELECTRICAL SPECIFICATILIN CODES, PERMITS AND FEES, CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH 2002 NATIONAL ELECTRICAL CODE AND FBC 2001 W/2003 REVISIONS- OBTAIN ALL PERMITS, PAY ALL FEES AND SECURE ALL INSPECTIONS REQUISITE FOR LAWFUL EXECUTION OF THIS WORK, SERVICE AND DISTRIBUTIONS EXTEND ELECTRICAL DISTRIBUTION AS INDICATED• REFER TO ONE LINE DIAGRAM BELOW. WIRINGS ALL INDOOR WIRING SHALL BE COPPER AND INSTALLED IN CONTINUOUS RACEWAY, ALL CONDUCTORS SHALL BE STRANDED THHN. COLOR CODE CONDUCTORS. GROUNDING PROVIDE' PULLEDGROUND CONDUCTORS IN ALL CIRCUITS. WORKMANSHIPS ALL WORK SHALL BE PERFORMED BY, OR UNDER DIRECT SUPERVISION [IF A DULY QUALIFIED TECHNICIAN. CLEAN UP ON A DAILY BASIS. REMOVE ALL DEBRIS INCIDENT TO THE PERFORMANCE OF THIS WORK, GUARANTY/ WARRANTY; ALL WORK SHALL BE GUARANTEED TO,THE OWNER FOR A PERIOD OF ONE (1) YEAR FROM PROJECT COMPLETION (OR FROM TIME OWNER TAKES BENEFICIAL USE, OF A PORTION OF BUILDING IF TURNED OVER IN PHASESX LABELING, PROVIDE ENGRAVED NAMEPLATES ON ALL DEVICES• WIRING, ALL WIRING SHALL BE 75'C/90'C COPPER AND INSTALLED IN CONTINUOUS RACEWAY. WIRING SHALL BE STRANDED THHN. COLOR CODE CONDUCTORS, WEATHER TIGHT FLEXIBLE CONDUIT SHALL BE USED OUTSIDE FOR EQUIPMENT CONNECTIONS, RACEWAYS UNDER SLAB OR OUTSIDE SHALL BE RGS. OR SCH. 40 PVC. OVERHEAD -SHALL BE EMT. CONDUIT EXPOSED TO PHYSICAL DAMAGE SHALL BE RGS, NEMA 3R PAD -LOCKABLE NOT .TO BE OPERATED Q UNDER LOAD F-----_---- ----_._--- --- -� ELEC. PANEL OR I I I I NEW 2000A. DEVICE 480/2-1-1 VOLT I ENCLOSED BREAKER L"O W/ KIRK KEY DEVICE EXI5TIN(fi 4000 AMP $U)ITCHBOARD L----------------- --- -I TAP_ 5Us 5 SETS OF fo00MC INCLUDING GROUND IN 4' CONDUIT PROVIDE CLEARANCES PER NEC CODE. REFER TO DETAIL THIS SHEET. .NORMALLY OPEN 2 j0(00 AMP, x•80/2'1"1 VOLT L� �REVIEWED SAFETY SWITCH CITY Y SAND r L A- ' l shy► GENERATOR QUICK CONNECT ASSEMBLY (MAX GENERATOR CONNECTION PEnMIT IS 1500KVA/1250KW). GENERATORNEW WORD15 TO HAVE MAXIMUM 200f0 AMP�+ EXISTING OVERCURRENT PROTECTION SINGLE ENDED 480/271 VOLT SERVICE N U SUP 0 (TYPICAL) , ♦, . , ♦ . �.` a O N t• W WLA ^ ^ O M z MM 1i a, a 01 • • , ; @d Q r0 el U IW Z W LL LL U CrZ W 0 U nmmni L1 LL W z REFER TO ONE LINE FOR • : • �: • : • : TTP, TYP.4 • . s � EXACT NUMBER & SIZES O N F 14' 4 4=�- PEAW DOCLOW rRAror� QlIGiC IM W Q; W N � www CONNECT A560113LY M ice 0 ,•; m v� O a:• • •..• .. .� 8. UNDERGROUND CONDUIT DETAIL � OF REQUIRED) •4 • 8 GC RETE P,LAB W PER ANNEX B, TABLE B,310,7 AND FIGURE B• 310.1 tuAY F�' " 30" psI 600MCM 75•C CONDUCTORS ARE TO BE DERATED TO .963%, WITH A RHO=55 AND A LF=, 938, PAD DET,411;_, SCA -E I NOMI? ENERAL INSTRUCTIONS ngle-Ended 4801277 Volt Service detailed Instructions are to be prepared If variance from the general instructions are wired) base instructions describe the steps required to canned a mobile temporary generator utilizing e Quid( Conned Assembly. Perform Steps in Order 1. Conned mobile generator to Quick Conned Assembly utilizing cables provided. If no cable is provided, utilize cable splice kits provided. Connect cables utilizing proper rotation. 2. At each transfer switch, move to manual position fed from the permanent emergency source. 3. Utilize Pad Lod( Assembly: a. Utility Company to pull primary transformer jacks. b. close, and lock in place, enclosed breaker for mobile generator connection c. Manual shedding of Non -Patent care loads as required so as to not overload mobile generator system, 4. Verify cable connections and dose safety switch at Quick Conned Assembly. 5. Start mobile generator. o disconnect from mobile united and return to utility power source, perform steps In reverse, #5 0 #1. Y N O N t• W WLA ^ ^ O M z MM 1i a, a LA @d Q r0 el U IW Z W LL LL U CrZ W 0 U nmmni L1 LL W z t >V W 00 O N F PEAW DOCLOW t IM W Q; W N � www H M ice 0 ,•; m v� O o N 211/480 VOLT SERVICE E1.33 a CL O ^ p 01 LA LA @d Q r0 el U IW CL 0 01 CL @d Q r0 el U IW U CrZ wv U rwrr LL 0 >V to V O N PEAW DOCLOW EtS" www RDH wre« ice .� 21 MARCH 2001511 SMLE ENDED 211/480 VOLT SERVICE E1.33