Loading...
6220-6241 Tarmac Way - BC07-000146 (SANFORD AIRPORT AUTH) (LG HANGAR) (A)PERMIT ADDRESS v 0 Z � � ��**040()SUB ISION * DATE CONTRACTORPERMIT ADDRESS = C t P 1/� d�C'L PERMIT DESCRIPTION unAaAA PERMIT VALUATION 3m2 S PHONE NUMBER 644 23 SQUARE FOOTAGE • ���7. PROPERTY OWNER O IJ E olPk ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE n O d CODES 2004 FLORIDA BUILDING CODE 2004 FLORIDA FIRE CODE WIND 5PEED 120 MPH NFPA 409 2001 CODE PARAMETERS DESCRIPTION ALLOWABLE PROVIDED BUILDING EXTERIOR NON-BEARING (30') 0 HOURS U5E/OCCUPANCY 5TORA5E, LOW HAZARD, GROUP 5=2 CON5TRUCTION TYPE TYPE V UNPROTECTED / UN5PRINKLED NFPA 409 GROUP III, TYPE 2 000 BUILDING AREA 0 HOUR5 16,000 5F PER FLOOR 11,932 5F MAX. NO. OF 5TORIE5 INTERNAL. PRE55URE COEFFICIENT +/- 2 1 MAX. HANGAR 5PACE JOB D15CRIPTION 12,000 5F 11,932 5F MAX. HGT. IN FEET 55' 20'=11.5' (ROOF PEAK) LARGE BOX WEND A2, 4.1, ETC_ 16 FIRE PROTECTION REQUIREMENTS (TABLE 600) 5TRUCTURAL FRAME 0 HOURS EXTERIOR BEARING 630') 0 HOURS PER TABLE 601 NOTE F EXTERIOR NON-BEARING (30') 0 HOURS INTERIOR BEARING WALL5 0 HOURS INTERIOR NON-BEARING WALLS 0 HOURS FLOOR 0 HOURS ROOF 0 HOUR5 ALPHABETICAL SEQUENCE. CLIENT NAME OCCUPANCY ANALY515 INTENDED FOR THE STORAGE OF AIRCRAFT. GENERAL CONDITIONS AND NOTES I. IT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND OCCUPANCY. ALL CONTRACTORS SHALL DO THEIR WORK IN CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. 2. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMEN51ONS AT THE JOBSITE PRIOR TO COMMENCING WORK CONTRACTOR SHALL REPORT ALL DISCREPANCIES IN THE DRAWINGS AND EXISTING CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCING WORK 3. CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD IN THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS, AND PITCHES A$ MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORW, 4. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ARCHITECT AND MAY NOT BE USED OR REPRODUCTED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. 5. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY 51MILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL 15 SHOWN. THE CONTRACTOR SHALL A CONSULT THE ARCHITECT IF THERE 15 ANY UNCERTAINTY REGARDING THE INTENT OR APPLICATION OF A DETAIL OR CONSTRUCTION ISSUE. 6. ALL DIMENSIONS AND ELEVATIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. 1. THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH AND MEETS THE REQUIREMENTS OF SECTION 1609, 2004 EDITION OF THE FLORIDA BUILDING CODE. IT 15 DESIGNED AS FOLLOWS TO WITHSTAND THE FOLLOWING LOAD5: 120 MPH WIND LOAD5 WITH SHAPE FACTORS. EXPOSURE B WIND LOADS IMPORTANCE FACTOR OF Im, BUILDING CATEGORY 11 s INTERAL PRE55URE COEFFICIENT 15 0.18 MINIMUM DESIGN PRESSURE FOR OPENINGS AND CLADDING IS +25.9, -28.1 PSF NET UPLIFT DE51GN PRE55URE SHALL BE 30 PF. DESIGN ROOF LIVE LOAD IS 20 P5F --ALL CONNECTIONS HAVE BEEN CHECKED TO WITHSTAND ALL APPLICABLE LOADS. 8. CONTRACTOR 15 SOLELY RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION. 9. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HAVING VISITED THE 51TE AND PAVING FAMILIARIZED HIMSELF WITH ALL EXISTING CONDITIONS. ANY QUESTIONS OR DISCREPANCIES FOUND WITH REGARD TO THE DRAWINGS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BEFORE SUBMITTING A PROPOSAL. 10. IT 15 THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THI5 INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER TEMPORARY BRACING, GUYS OR TIE -DOWNS MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. 11. IF MATERIALS, QUANTITIES, 5TRENGTH5 OR SIZES INDICATED BY THE DRAWINGS OR SPECIFICATIONS ARE NOT IN AGREEMENT WITH THESE NOTES, THE BETTER QUALITY AND/OR GREATER QUANTITY, STRENGTH OR 51ZE INDICATED, 5PEGIEIED OR NOTED SHALL BE PROVIDED. 12. 'PROJECT SHALL BE TURNED OVER TO OWNER IN CLEAN CONDITIONS WITH ALL TRASH AND DEBRIS REMOVED FROM SITE, ALL WINDOWS AND GLASS CLEAN, ALL FLOORS CLEAN, ALL HORIZONTAL 5URFACE6 DUSTED AND CLEANED, AND ALL TOILET AND PLUMBING FIXTURES CLEAN AND IN GOOD WORKING ORDER 13. CONTRACTOR SHALL HAUL ALL RUBBISH FROM SITE ON A REGULAR BASIS, AND SHALL NOT ALLOW DEBRIS TO ACCUMULATE. 14. CONTRACTOR TO OBTAIN ALL PERMITS, AND PAY ALL FEES AND TAXES_ 15. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE BASED ON THE BEST AVAILABLE DATA AS PROVIDED BY THE OWNER BEFORE PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS OR OTHER CONDITIONS OF LIMITATIONS AT THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK 15 PERFORMED BY THE CONTRACTOR OR ANY SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, ANY RESULTANT EXTRA C05T FOR ADJUSTMENT OF WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR SCALING DIMENSIONS FROM PLANS 15 PROHIBITER I6. A DESIGNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPEMNT SHALL BE DETERMINED BY THE OWNER CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, STORING, PLACING AND PROTECTING FROM DAMAGE ALL NEW EQUIPMENT AND MATERIALS FURNISHED BY THE CONTRACTOR, OR BY THE OWNER FOR THE CONTRACTORS USE. 11. CONTRACTOR SHALL PROVIDE, AND SUBMIT WITH PERMIT APPLICATION, ALL PRODUCT CERTIFICATIONS AND MANUFACTURER'S INSTALLATION SPECIFICATIONS FOR SELECTED MATERIALS REQUIRED FOR EXTERIOR CLADDINGS, ROOFING, AND STRUCTURAL CONSTRUCTION COMPONENTS, SHOWING COMPLIANCE WITH STATE OF FLORIDA PRODUCT APPROVAL COMPLIANCE, FOUNDATIONS 1, SUBSURFACE SOIL CONDITIONS INFORMATION IS NOT AVAILABLE. FOUNDATION DESIGN IS BASED ON AN ASSUMED ALLOWABLE BEARING PRE55URE OF 2000 PSF AND SHALL BE VERIFIED BY A GEOTECHNICAL ENGINEER REG15TRERED IN THE STATE OF FLORIDA CONTRACTOR OR OWNER TO PROVIDE AS REQUIRED BY BUILDING OFFICIAL_ 2. ALL REQUIREMENTS FOR 51TE PREPARATION AND SOIL COMPACTION SPECIFIED IN THE 501L5 REPORT SHALL BE FOLLOWED UNLESS ADDITIONAL MORE STRINGENT REQUIREMENTS ARE SPECIFIED. NOTIFY ARCHITECT IF FOUNDATION CONDITIONS ENCOUNTERED DIFFER FROM SOILS EXPLORATION INFORMATION MADE AVAILABLE TO THE CONTRACTOR 3. 501L SHALL BE COMPACTED TO A MINIMUM OF 95`o OF MAXIMUM MODIFIED PROCTOR DENSITY. 4. ALL FOOTINGS SHALL BE CENTERED UNDER THE COLUMN OR WALL ABOVE UNLESS NOTED OTHERWISE. 5. BACKFILL AGAINST A WALL SHALL BE PLACED EVENLY ON BOTH SIDES OF THE WALL UNLESS THE WALL 15 FULLY BRACED BY THE CONTRACTOR FOR LATERAL PRESSURE. SUCH BRACING, INCLUDING ITS DESIGN, 15 THE SOLE RESPONSIBILITY OF THE CONTRACTOR AND SHALL REMAIN IN PLACE UNTIL AFTER THE FLOOR SLAB OR OTHER STRUCTURAL ELEMENT BRACING THE WALL HAS BEEN CONSTRUCTED To THE 5AT15FACTION OF THE ARCHITECT. CAST IN PLACE CONCRETE I. ALL CONCRETE SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON GRADE AND FOOTINGS 3000 PSI REMAINING CONCRETE 3000 PSI 2. ALL CONCRETE SHALL HAVE A SLUMP OF 4' PLU5 OR MINUS 1', AND HAVE 2 TO 4% AIR ENTRAINMENTS, AND A MAXIMUM WATER/CEMENT RATIO OF 058. 3. CONCRETE MIX DESIGN SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AGI 301 CHAPTER 3, METHOD I OR METHOD 2. SUBMIT BACKUP DATA AS REQUIRED BY CHAPTER 5 SECTION 53 OF THE LATEST EDITION OF ACI 318 4. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFORMED BILLET STEEL CONFORMING TO A5TM A-615 GRADE 60. 5. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH 'THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' AGI 318 LATEST EDITION, AND 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS,' ACI 301. 6, WHERE BAR LENGTHS ARE GIVEN ON THE DRAWINGS, THE LENGTH OF ANY HOOK, IF REQUIRED, 15 NOT INCLUDED. HOOKS SHALL BE PROVIDED AT DISCONTINUOUS ENDS OF ALL TOP BARS OF BEAMS AND AT SLABS EDGES. 1. CONTRACTOR SHALL PROVIDE SPACERS, CHAIRS, BOLSTERS, ETC. NECESSARY TO SUPPORT REINFORCING STEEL. SUPPORT ITEMS WHICH BEAR ON EXPOSED CONCRETE SURFACES SHALL HAVE ENDS WHICH ARE PLASTIC TIPPED OR STAINLESS STEEL. 8. CONTRACTOR SHALL PROVIDE 3/4 INCH CHAMFER ON ALL EXPOSED CORNERS OF COLUMNS, BEAMS, AND WALLS UNLESS OTHERWISE INDICATED ON THE ARCHITECTURAL DRAWINGS. 9. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT: 3' CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. 2' CONCRETE EXPOSED TO EARTH OR WEATHER % THROUGH "18 BARS 11/2' ALL OTHER CASES 10, MINIMUM LAP SPLICES ON ALL REINFORCING BAR SPLICES SHALL BE 48 BAR DIAMETERS TYP. EXCEPT WHERE OTHERWISE NOTED ON THE DRAWINGS. It WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. WWF SHALL BE LAPPED AT LEAST 6' AND CONTAIN AT LEAST ONE CROSS WIRE WITHIN THE 8'. 12. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, ANCHOR BOLTS, INSERTS, ETC., AS REQUIRED BY OTHER TRADES BEFORE CONCRETE IS PLACED. 13. HORIZONTAL WALL, BEAM AND FOOTING BARS SHALL BE BENT I'-0' AROUND CORNERS OR CORNER BARS WITH 24' LAP SHALL BE PROVIDED. 14, ALL REINFORCING DETAILS SHALL CONFORM TO 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES' ACI 315 LATEST EDITION, UNLE66 DETAILED OTHEW16E ON THESE PLANS. 15. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND MECHANICAL DRAWINGS FOR 51ZE AND LOCATION OF EMBEDDED ITEMS, SLEEVES, SLAB DEPRESSIONS, SLOPES, ETC. REQUIRED BY OTHER TRADES. THESE ITEMS HALL BE FUFIISHED AND INSTALLED PRIOR TO PLACEMENT OF CONCRETE. I6. FOR BEAMS, LAP BOTTOM STEEL AT THE SUPPORT AND TOP STEEL OVER THE MID5PAN, UNLE65 NOTED OTHERWISE. Il, TESTING LABORATORY SHALL SUBMIT ONE COPY OF ALL CONCRETE TEST REPORTS DIRECTLY TO THE ARCHITECT. SYMBOLS KEY ROOMTITLE ROOM FIRST DIGIT REPRESENTS FLOOR 101 TARGET S REPRESENT LEVELROOM NUMBER REMAINING I01TTHRU 99 I01A DOOR DOORS LABELED BY NUMBER OF SPACE INTO WHICH DOOR SWINGS, PREPARED BY SiMPOL FOLLOWED BY LETTERS IN B ALPHABETICAL SEQUENCE. CLIENT NAME WINDOW INTERNAL. PRE55URE COEFFICIENT +/- O �1'MBOL NUMBERED BY TYPES. JOB D15CRIPTION GRID LINE DIRECTION! A, E1 2, 3, ETC, IN THE OTHER OTARGET LOCATIONS OFF MAIN GRID NOTED A5 NOTED LARGE BOX WEND A2, 4.1, ETC_ 16 DRAW. NO. �DRWG. TITLE O TITLE Al AWING 151 1/4'=1'-0' -- SCALE MAJOR BLDG. 5ECTION ROOF 5LOPE (X:12) DETAIL NO. Al NDICATE5 DIRECTION OF GENERAL NOTES DETAIL CUT AND/OR LOCATION. ME OPENING OPENING SHEET ON WHICH OPENING DETAIL IS DRAWN. PARTIAL SECTION ZONE DETAIL WIDTH (Ft) HEIGHT (Ft) AI 5F) PRE55URE ( 5F) REFERENCE PARTITION SECTION 1 48 AI -10.4 ARTITION TYPE A INTERIOR �Ar ELEVATION 1 60 DIRECTION OF VIEW, GENERAL NOTE NUMBER NOTE ®1 LOCATION OF 3 NOTE APPLICATION. MATERIAL NOTE NUMBER NOTE 04200"'� LOCATION OF 8 NOTE APPLICATION. I I I I WIND VELOCITY (MPH) 120 m COMPANY ERIC KURITZKY, ARCHITECT IMPORTANCE FACTOR 1.00 o PREPARED BY ERIC KURITZKY, ARCHITECT EXPO5URE CATEGORY B O_ CLIENT NAME TRACY FORRE5T INTERNAL. PRE55URE COEFFICIENT +/- 0.18 0 JOB D15CRIPTION 5ANFORD HANGAR5 MEAN ROOF HEIGHT (FT) 21 m A5 NOTED LARGE BOX WEND BUILDING WIDTH (FT) 16 JOB NUMBER 25053.2 BUILDING LENGHT (FT) 151 U O ROOF 5LOPE (X:12) .5 x a GENERAL NOTES ME OPENING OPENING M LOCATION OPENING OPENING DIME N5ION5 MAXIMUM P051TIVE MAXIMUM NEGATIVE MARK DE5CRIPTION ZONE ELEVATION WIDTH (Ft) HEIGHT (Ft) PRE55URE ( 5F) PRE55URE ( 5F) 101 OVERHEAD 5 1 48 14 11.1 -10.4 102 OVERHEAD 5 1 60 14 16.4 -11] 103 HOLLOW METAL 4 333 3 6106 22.6 -29.5 104 OVERHEAD 5 5 8 8 20.2 -222 N m 0 _. c 0 r,ri i rr i_r STRIP (a) IN 4 A3 SOUTHEAST RAMP -PHASE 2A � � �A> BAR PROVIDE PURPLE K�EWALKS, DRIVEWAYS 4 PAVING. FE -FIRE EXTINGUISHERS LARGE BOX HANGAR WIND UNIT 2 a3 i atitord Fire -Frey t� m m c DRAWN o CJD CHECKED O_ r� DATE 0 4/12 /0% m SCALE m A5 NOTED PROJECT NO. 25053.2 U O � x a GENERAL NOTES LANN G2wc F 0 P Y L SHEET Y o � 0 U m Al 0 c ■ p � N m 0 _. c 0 N L � ®� C 5 v r DRAWN o CJD CHECKED DATE 0 4/12 /0% m SCALE m A5 NOTED PROJECT NO. 25053.2 U LARGE BOX W/END x a GENERAL NOTES LANN G2wc F 0 P Y SHEET Y 0 U w w Al 0 ■ 7 kFr-- F5 F5F5 _ / \ IF2 IF 2 �F2 F1 Hr9 \ FROM'- ',U► RUM_ C.J. (TYP.) 1/8" x i" DEEP 5 WITHIN 12 HOURS WCUT F5 OF POUR F4 - - - - \ - - - - - 8'-0° X -20'= 0" MAT O F 6x6 1.4 / 1.4 WWM AT EA. INTEIROR FOOTING F2� II \ I 4" THICK MIN. 3000 P5I CONC. (TYP) I 5LA5 W/ 6X6 1.4 X 1.4 WMM ON 6 I I I j I MIL. V15OUEEN ON COMPACTED TERMITE TREATED FILL F5 I �Q 8JI - F5 SLOPE 2' I I I NOTE: CONCRETE CONTRACTOR 5ET IN PLACE ANCHOR BOLT5 TO MFGR ANCHOR BOLT SETTING PLAN J , TEMPLATE5 REQ'D (4" i F4 F4 PROJECTION MAX) GRADE 60 REBAR, 25" MIN. LAP 05 HAIRPIN (TYP.) BARS MIN. 15'-0" LEGS 6" I F0 RVC AC CHASE - - OPT. ATH P B R OOM5 I - _ - - - - I - - - - � F2 / F5 F2 / \ / #5 HAIRPIN (TYP.) BEND 20'-0" BARS MIN. 9'-0" LEGS FT F5 / F F5 \ I / F F5 I F F5 ;IF 1 \ _ e ot, FROM'- ',U► RUM_ D J, I 7� ^te^a h� C/-1 cy-5 DOOR 5CNEDULE SYMBOL xx DOOR FRAME EMS. SHEET A4 CLOSURE RATED MTL THRESH H� SPECS PRE56URE POSITIVE PRESSURE NEGATIVE REMARKS LOCATION TYPE WIDTH HEIGHT THICK MAT'L fiRADE MAT'L HEAP JJAMB THRESH 101 HANGAR D 40' 14' - - - - - - - - - - - - REQ. TO MFCxR 5PEG --- --- --- 11.1 -1a.4 OVERHEAD DOOR W/ TRANS. PANEL W/ HYDROLIFT 102 HANGAR D 60' 14' - - - - - - - - - - - - REF, TO MFGR MPEG - - - - - - --- 16.4 -11.1 OVERHEAD DOOR W/ TRANS. PANEL W/ HYDROLIFT 103 HANGAR A 3'-0'' 6'=a" 13/4" MTL PAINT HOLLOW/MTL Cl— GI G2 YES --- YE6 22.6 -29.5 FLUSH PANEL DOOR 104 HANGAR B --- STEEL PAINT --- --- --- --- --- --- --- 20.2 -22.2 GARAGE DOOR (TYP) W/ HIGH LIFT 105 HG BATHROOM C 3'-0" 6'-a" 1 3/4" MTL PAINT HOLLOW/MTL Al A2 A3 YE5 --- YE5 FLUSH PANEL DOOR 106 HG 5ATHROOM C 3'-0" 6'-a" 13/4"1 MTL 110,41NTIHOLLOW/MTL 1 Al 42 A3 YE5 20MIN, YE5 FLUSH PANEL DOOR WITH RATED HARDWARE A cll�a F q � e U V (� o a z O F O O � � A � � � d z � L O W x P Q ° o H.V.A.C. SPECIFICATIONS GENERAL SCOPE OF WORK FURNISH AND INSTALL COMPLETE AIR GONDITIONING SYSTEMS AS INDICATED ON THE DESIGN DRANINC75 AND AS OUTLINED WITHIN THESE SPECIFICATIONS. WORK SHALL INCLUDE BUT NOT BE LIMITED TO THE FABRICATION AND/OR INSTALLATION OF THE SCHEDULED AIR GONDITIONING UNITS, EXHAUST FANS, AIR DISTRIBUTION AND DUGTWORK. RELATED WORK SPECIFIED ELSEWHERE REFER TO ELECTRICAL SPECIFICATIONS FOR ALL ELECTRICAL WORK PERFORMED IN CONJUNCTION WITH MECHANICAL WORK. DIVISION 15 CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL CONDUIT, WIRING, JUNCTION BOXES, ETC. REQUIRED FOR COMPLETE, WORKING HVAG CONTROLS AND EQUIPMENT. ODES AND STANDA ALL MECHANICAL WORK SHALL BE GOVERNED AND INSTALLED IN ACCORDANCE WITH THE APPLICABLE PROV I S I ONS OF THE FLORIDA BUILDING CODE 2004, NATIONAL ELECTRIC CODE, FLORIDA MECHANICAL CODE 2004, FLORIDA FIRE PREVENTION CODE 2004, FLORIDA LIFE SAFETY CODE 2004, AMERICANS WITH DISABILITIES ACT, ASHRAE STANDARDS, ANSI, SMAGNA, AND FLORIDA ENERGY EFFICIENCY FOR BUILDING CONSTRUCTION 2004. NO WORK SHALL BE COVERED OR CONGEALED UNTIL PROPERLY INSPECTED AND TESTED. PRODUCTS ALL EQUIPMENT AND APPURTENANCES SHALL BE NEW UNLE55 OTHERWISE NOTED. SUBSTITUTIONS EQUIPMENT AND DESIGN OF 5Y5TEM5 AS INDICATED ON THE PRANINC75 AND WITHIN THESE SPEGIFIGATIONS SHALL BE CONSIDERED AS THE SPECIFIED STANDARD OF QUALITY. 5UB5TITUTION5 OF EQUIPMENT WITH EQUAL OR BETTER SPECIFICATIONS MAY BE SUBSTITUTED. WORKMANSHIP ALL MATERIALS SHALL BE FABRICATED AND INSTALLED IN A NEAT, WORKMANLIKE MANNER. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES TO AVOID CONFL I GTS AND DELAYS. NO ALLOWANGES WILL BE MADE FOR REWORK DUE TO GOORDINATION CONFLICTS WITH OTHER TRADES. NO WORK SHALL BE COVERED OR CONGEALED UNTIL PROPERLY INSPECTED AND TESTED. WARRANTY/GUARANTEE: THE CONTRACTOR SHALL WARRANTY/GUARANTEE AND MAINTAIN THE: STABILITY OF WORK AND MATERIALS AND KEEP SAME IN PERFECT REPAIR AND CONDITION OF THE PERIOD OF ONE (1) YEAR. DEFECTS OF ANY KIND DUE TO FAULTY WORK OR MATERIALS APPEARING DURING THE ABOVE MENTIONED PERIOD MUST BE IMMEDIATELY MADE GOOD BY THE CONTRACTOR AT H15 OWN EXPENSE TO THE ENTIRE 5AT15FAGTION OF THE OWNER AND ARCHITECT AND ENGINEER. SUCH RECONSTRUCTION AND REPAIRS SHALL INCLUDE ALL DAMAGE TO THE FINISH OR FURNISHING OF THE BUILDING RESULTING FROM THE ORIGINAL DEFECT OR REPAIRS THERETO. H.V.A.C. LEGEND DOUBLE LINE SINGLE LINE DUCT DIMENSION A x B A x B (A = HORIZONTAL, B = VERTICAL)-� SPIN -IN FITTING W/DAMPER e (SIDE TAPPIN(5) aOlb ELBOW WITH TURNING VANES RADIUS ELBOW EXHAUST AIR DUCT UP �--� EXHAUST AIR DUCT DOWN �--� RIGID ROUND DUCT UP (`,) I •� RIGID ROUND DUCT DOWN �--� MANUAL VOLUME DAMPER ® EXHAUST GRILLE O DRAWING HEX NOTE Q REVISION DELTA AND NUMBER EXECUTION DRAWINGS ARE GENERALLY DIAGRAMMATIG AND DO NOT NEGE55ARILY SHOW EVERY FITTING AND DETAIL. INSTALL DUCTS, EQUIPMENT AND CONTROLS IN A NEAT WORKMANLIKE MANNER AND IN ACCORDANCE WITH GOOD PRACTICE FOR A COMPLETE, WORKABLE INSTALLATION. AVOID CONFLICT WITH OTHER TRADES; MAKE ADEQUATE PROVISIONS FOR PREVENTING NOISE AND VIBRATION. ARRANGE EQUIPMENT IN THE AVAILABLE SPACE TO MAKE ALL WORKING PARTS AGGE551BLE FOR MAINTENANCE AND SERVICE. CONTRACTOR IS RESPONSIBLE FOR ALL FIELD MEASUREMENTS REQUIRED TO PROVIDE AN APPROVED, FUNCTIONAL INSTALLATION. IT IS TO BE UNDERSTOOD THAT UNFORESEEN CONDITIONS MAY EXIST AND WORK MAY NOT BE LOCATED OR INSTALLED EXACTLY AS INDICATED ON THE DRAWINGS. DEVIATIONS REQUIRED TO COORDINATE WITH OTHER TRADES SHALL BE CONSIDERED PART OF THIS CONTRACT. NO WORK SHALL BE COVERED OR CONGEALED UNTIL PROPERLY INSPECTED AND TESTED. HANGERS AND SUPPORTS PROVIDE ALL NECESSARY DUGTWORK, PIPE SUPPORTS, HANGER, RODS, CLAMPS AND ATTACHMENTS TO PROPERLY INSTALL AND SUPPORT DUGTWORK, PIPING AND EQUIPMENT FROM THE BUILDING STRUCTURE. PROVIDE ANY ANGLE IRON OR UN15TRUT AND SUSPENSION RODS REQUIRED TO INSTALL EQUIPMENT, PIPING AND DUGTWORK. THE USE OF BALING WIRE OR PERFORATED METAL STRAPPING IS NOT ACCEPTABLE FOR SUPPORTS. EXHAUST FANS: FURNISH EXHAUST FANS WITH PERFORMANCE AND GAPACITIES AS LISTED ON THE DESIGN DRAWINGS. ALL EXHAUST FANS SHALL COME WITH INTEGRAL BAGKDRAFT DAMPERS. SUSPENDED FANS SHALL BE SUPPORTED FROM A TRAPEZE -TYPE HANGER WITH SPRING -MOUNTED VIBRATION ISOLATORS. GOORDINATE WITH ARCHITECT TO LOCATE EXHAUST FANS, EXHAUST GRILLES, WALL OR ROOF GAPS A MINIMUM DISTANCE OF IO' -O" FROM ANY OPERABLE WINDOW, DOOR OR FRESH AIR INTAKE. OUGTWORK: MATERIALS: GALVANIZED STEEL OF GAUGES GONFORMING TO LATEST EDITION OF SMAGNA STANDARDS BASED ON 2" W.G. PRESSURE UNLESS SPECIFICALLY NOTED OTHERWISE ON THE DRAWINGS. THE GALVANIZED DUCT GOATING IS TO BE 6-a0. ALL DIMENSIONS ARE INSIDE NET FREE AREA. SEAL ALL JOINTS AND SEAMS WITH MEDIUM PRESSURE DUCT SEALANT. FIBERGLASS DUGTBOARD MAY BE SUBSTITUTED; PROVIDE MINIMUM R-6, SEAL ALL JOINTS WITH FABRIG TAPE AND MASTIC. FAN FROM STRUCTURE DUCTWORK FLEXIBLE CONNECTION PROVIDE TRANSITION FROM FAN DISCHARGE TO DUCTWORK DISCHARGE DUCTWORK. REFER TO PLANS FOR SIZE AND LOCATION CEILING CABINET FAN - CEILING EXHAUST GRILLE L CEILING (TYPICAL) REFER TO ARCH. DWGS. FOR TYPE AIR FLOW CEILING CABINET EXHAUST FAN NOT TO SCALE ATTACH TO STRUCTURE PER SMACNA RF__.........�.... 1 1/2' MII DIAMETER I NOTE ,N,l_.,,k.k«U kms" METAL SADDLE ROUND FLEXIBLE DUCTWORK RECTANGULAR DUCTWORK —0 ATTACH TO STRUCTURE PER SMACNA RECOMMENDATIONS. 1 1/2" MIN. SHEETMETAL STRAP (TYPICAL) 1. DO NOT USE POWDER ACTIVATED FASTENING SYSTEMS TO ATTACH SUPPORTS 4. SUPPORT HORIZONTAL FLEXIBLE DUCT EVERY 5'-0° MINIMUM. TO STRUCTURE. 5. DUCT SAG BETWEEN SUPPORTS SHALL NOT EXCEED 1/2" 2. SUPPORT SYSTEM MUST NOT DAMAGE DUCT, INSULATION, OR CAUSE DUCT PER FOOT OF LENGTH. SHAPE DEFORMATION. 6. FLEXIBLE DUCTS SHALL BE INSTALLED FULLY EXTENDED. 3. HANGER SIZES SHALL BE IN ACCORDANCE WITH SMACK LATEST EDITION. DUCTWORK SUPPORT DETAIL NOT TO SCALE 5. INTERLOCK FAN WITH LIGHT SWITCH; PROVIDE TEN MINUTE TIME DELAY RELAY. HVAC FLOOR PLAN 1/8, = 1'-0° 3 O T � o h k w M O Q MLB x FAN SCHEDULE o 6/13/06 r U SYMBOL LOCATION SERVICE TYPE � FAN DATA q DATA O CFM ESP (IN W. G.) FAN RPM MAX. SONES DRIVE HP (MAX WATT) RPM VOLT PH. HZ. U EF -1 TOILET ROOM EXHAUST CEILING CABINET 80 0.250 1500 3.6 DIRECT (75) 1750 110 1 60 b O Z EF -2 TOILET ROOM EXHAUST CEILING CABINET 80 0.250 1500 3.6 o DIRECT (75) 1750 110 1 60 0 c C3 a a o SYMBOL PHYSICAL CHARACTERISTICS CONTROLLED BY MANUFACTURER MODEL NUMBER REMARKS DIMENSIONS LxWxH (in) WEIGHT (LBS.) OUTLET DIMS LxW (in.) EF -1 13.5 x 15.5 x 12 15 6"0 WALL SWITCH COOK GC -140 ALL EF -2 13.5 x 15.5 x 12 F15 6"0 WALL SWITCH COOK GC -140 ALL REMARKS 1. 2. PROVIDE DISCONNECT SWITCH PER CODE REQUIREMENTS. PROVIDE INTEGRAL BACKDRAFT DAMPER. 3_ PROVIDE BIRDSCREEN AT OUTLET. 4. PROVIDE VARIABLE SPEED SWITCH FOR BALANCING AND ROOF JACK. 5. INTERLOCK FAN WITH LIGHT SWITCH; PROVIDE TEN MINUTE TIME DELAY RELAY. HVAC FLOOR PLAN 1/8, = 1'-0° 3 O T � o h k w M O Q MLB x v o 6/13/06 r U o Q CL � � M N q O Boz� o E U Zvi v N g:, } co GA � P b O Z V � o i w � o U m w q W U x 0 c C3 a a o CAM o C E ­4E -+—I o O CL �-+ w O • � w o E— CL M --I V CL c.� O o c�z 0 DRAWN o MLB a MLB x v o 6/13/06 r r~ rn o � NO. � M N t Boz� o E U Zvi v N } co GA 0 A b O Z 00 Eoo"o �_4 CAM o C E ­4E -+—I o O CL �-+ w O • � w o E— CL M --I V CL c.� O o c�z 0 DRAWN o MLB CHECKED MLB DATE 0 6/13/06 SCALE ID AS NOTED PROJECT NO. U - W HVAC PLAN, SPECIFICATIONS ,- & DETAILS Y N SHEET Y c U W tia ■ SECTION 15400 PLUMBING PART1 GENERAL A.MANUFACTURERS: 1.1 SECTION INCLUDES 1. B LINE. A. GENERAL PROVISIONS SPECIFICALLY APPLICABLE TO DIVISION 2.OTHER ACCEPTABLE MANUFACTURERS OFFERING EQUIVALENT PRODUCTS. 15 SECTIONS, IN ADDITION TO DIVISION 1 - GENERAL REQUIREMENTS. A) MICHIGAN HANGER. B) PHD. 1.2 SCOPE PLUMBING FIXTURE CONNECTION SCHEDULE SATISFACTION OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL 2.2 A. THE WORK SHALL INCLUDE THE PROVISIONS OF SYSTEMS, PA EQUIPMENT AND MATERIALS SPECIFIED IN THIS DIVISION AND AS COUPLED TANK AND LID, TRIP LEVER. CALLED FOR ON THE DRAWINGS. WORK SHALL ALSO INCLUDE A. SUPERVISION, OPERATION, METHODS AND LABOR FOR THE STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. FABRICATION, START-UP AND TESTS FOR A COMPLETE OPERATIONAL McGUIRE NO. H172 -LK, CHROME PLATED ANGLE LOOSE -KEY STOP, 12" LONG COPPER TUBE RISER PLUMBING INSTALLATION. AND ESCUTCHEON. F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES B. B. DRAWINGS FOR THE WORK ARE DIAGRAMMATIC IN NATURE AND FLUSH TANK, ADA COMPLIANT, 12" ROUGH -IN, 1.6 GALLONS PER FLUSH, 2" GLAZED TRAPWAY, CLOSE - ARE INTENDED TO CONVEY THE SCOPE OF THE INSTALLATION AND TO C INDICATE THE GENERAL ARRANGEMENT AND LOCATIONS OF THE WORK. BEMIS TOILET SEAT NO. 1955C, WHITE, HEAVY-DUTY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER, BECAUSE OF THE SCALE OF THE DRAWINGS, CERTAIN BASIC ITEMS STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. SUCH AS PIPE FITTINGS, ACCESS PANELS, AND SLEEVES MAY NOT D. BE SHOWN. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR AND ESCUTCHEON. SELECTING THE EQUIPMENT TO FIT THE SPACE PROVIDED. THE 2.3 LOCATION AND SIZES FOR PIPE FITTINGS, SLEEVES, INSERTS, ADA COMPLIANT, 4" CENTER FAUCET DRILLING, FRONT OVERFLOW, BACKSPLASH. FIRE AND/OR SMOKE DAMPERS, AND OTHER BASIC ITEMS REQUIRED AMERICAN STANDARD "RELIANT +" NO. 2385.406, CHROME PLATED BRASS CONSTRUCTION, 4" CENTERSET, BY CODE AND OTHER SECTIONS SHALL BE COORDINATED AND ADA COMPLIANT, 0.50 GPM VANDAL RESISTANT AERATOR, LESS POP-UP AND POP-UP HOLE, CERAMIC DISC INCLUDED FOR THE PROPER INSTALLATION OF THE WORK. VALVE CARTRIDGE, ADJUSTABLE HOT LIMIT SAFETY STOP. C. EQUIPMENT SPECIFICATIONS MAY NOT DEAL INDIVIDUALLY WITH McGUIRE MANUFACTURING NO. PW2125WC, CHROME PLATED BRASS CONSTRUCTION, ADA COMPLAINT, MINUTE ITEMS REQUIRED SUCH AS COMPONENTS, PARTS, CONTROLS 2.4 AND DEVICES WHICH MAY BE REQUIRED TO PRODUCE THE EQUIPMENT IS PREINSULTED (INCLUDING SUPPLY STOP ASSEMBLIES) IN ACCORDANCE WITH ADA REQUIREMENTS. PERFORMANCE SPECIFIED OR AS REQUIRED TO MEET THE EQUIPMENT McGUIRE NO. H170 -LK, CHROME PLATED ANGLE LOOSE -KEY STOPS, 12" LONG COPPER TUBE RISERS WARRANTIES. WHERE SUCH ITEMS ARE REQUIRED, THEY SHALL BE AND ESCUTCHEONS. INCLUDED BY THE INSTALLER OF THE EQUIPMENT, WHETHER OR NOT WOODFORD NO. 24, CHROME PLATED HOSE BIBB, WITH POLYCARBONATE HANDLE, SPECIFICALLY INDICATED IN THE CONTRACT DOCUMENTS WITH NO ASSE STD 1011 VACUUM BREAKER. ADDITIONAL COST INCURRED. ZURN NO. Z1400 -HD, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, D. WHERE NOTED ON THE DRAWINGS OR INDICATED IN OTHER ROUND SCORIATED HEAVY-DUTY SECURED TOP. SECTIONS OF THE SPECIFICATION THE CONTRACTOR FOR THIS ZURN NO. ZB1400, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, HOT WATER WATER PIPING INSULATION (INCLD RECIRC PIPING) Manufacturers: 1. Owens-Corning 2. Johns -Manville 3. Knauf ASTM C547, rigid molded non-combustible fiberglass insulation. 'K' value .024 at 75 degrees F. Vapor Barrier Jacket, Kraft paper with glass fiber yarn and bonded to aluminized film Closure system shall be UL 181. Insulation Thickness: 1-1/2" PIPING: SANITARY SEWER PIPING, BELOW AND ABOVE GRADE (NON -PLENUM AREAS ONLY). THIS PIPING ONLY ALLOWED WITHIN RESTROOM WALLS AND BELOW SLAB. A. PVC: ASTM D2665 SCHEDULE 40 PVC PIPING/ 1. FITTINGS: SCHEDULE 40 PVC. 2. JOINTS: CASTM D2855 SOLVENT WELD WITH ASTM D2564 SOLVENT CEMENT PIPING: SANITARY SEWER PIPING, ABOVE GRADE IN PLENUM AREAS AND IN RATED PARTITIONS. CAST IRON TO BE PROVIDED IN PLENUM AREAS. A. CAST IRON PIPING: CISPI 301 HUBLESS SERVICE WEIGHT. 1. FITTINGS: CAST IRON 2. JOINTS: CISPI 310, STAINLESS STEEL CLAMP -AND SHIELD HUSKEY SERIES 4000 OR CLAMP -ALL ONLY. DIVISION SHALL INSTALL PLUMBING EQUIPMENT FURNISHED BY 2.5 PIPING: WATER PIPING, ABOVE GRADE OTHERS, AND SHALL MAKE ALL FINAL CONNECTIONS. CONTRACTOR A. COPPER PIPING: ASTM B88 TYPE 'L' HARD DRAWN. SHALL INSTALL EQUIPMENT AND SYSTEMS IN STRICT ACCORDANCE 1. FITTINGS: ASTM B16.8 CAST BRONZE OR ASTM B16.22 WROUGHT WITH MANUFACTURERS RECOMMENDATIONS. COPPER OR BRONZE. E COORDINATE WITH ALL TRADES IN SUBMITTAL OF SHOP 2. JOINTS: ASTM B32 SOLDER, ASTM 95TA MINIMUM. DRAWINGS. TIGHT SPACE CONDITIONS SHALL BE DETAILED TO THE PLUMBING FIXTURE CONNECTION SCHEDULE SATISFACTION OF ALL TRADES, SUBJECT TO THE REVIEW AND FINAL AMERICAN STANDARD "CADET" NO. 2898.012, WHITE VITREOUS CHINA, FLOOR MOUNTED, ACCEPTANCE OF THE ARCHITECT/ENGINEER. IN THE EVENT THAT PA THE CONTRACTOR INSTALLS HIS WORK BEFORE COORDINATING WITH COUPLED TANK AND LID, TRIP LEVER. OTHER TRADES OR SO AS TO CAUSE ANY INTERFERENCE WITH THE BEMIS TOILET SEAT NO. 1955C, WHITE, HEAVY-DUTY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER, WORK OF THE OTHER TRADES THIS CONTRACTOR SHALL MAKE ALL STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. REQUIRED CHANGES TO CORRECT THE CONDITION AT NO ADDITIONAL McGUIRE NO. H172 -LK, CHROME PLATED ANGLE LOOSE -KEY STOP, 12" LONG COPPER TUBE RISER COST TO THE PROJECT. AND ESCUTCHEON. F. CONTRACTOR SHALL VERIFY ALL EQUIPMENT CONNECTION SIZES AMERICAN STANDARD "CADET RIGHT HEIGHT" NO. 2998.012, WHITE VITREOUS CHINA, FLOOR MOUNTED, PRIOR TO INSTALLATION OF ANY SYSTEMS. THIS CONTRACTOR SHALL FLUSH TANK, ADA COMPLIANT, 12" ROUGH -IN, 1.6 GALLONS PER FLUSH, 2" GLAZED TRAPWAY, CLOSE - ADJUST PIPING SYSTEM SIZES AS REQUIRED TO MATCH EQUIPMENT COUPLED TANK AND LID, TRIP LEVER. CONNECTIONS. UTILIZE REDUCERS WHERE EQUIPMENT CONNECTIONS BEMIS TOILET SEAT NO. 1955C, WHITE, HEAVY-DUTY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER, ARE SMALLER THAN PIPE SIZES INDICATED ON PLANS, NO PIPING STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. SHALL BE DECREASED IN SIZE (IN THE DIRECTION OF FLOW). McGUIRE NO. H172 -LK, CHROME PLATED ANGLE LOOSE -KEY STOP, 12" LONG COPPER TUBE RISER G. EXAMINATION OF BIDDING DOCUMENTS: AND ESCUTCHEON. 1. EACH BIDDER SHALL EXAMINE THE BIDDING DOCUMENTS AMERICAN STANDARD "LUCERNE" NO. 0355.012, WHITE VITREOUS CHINA, WALL HUNG, CONCEALED ARM, CAREFULLY AND NOT LATER THAN TEN (10) DAYS PRIOR TO THE ADA COMPLIANT, 4" CENTER FAUCET DRILLING, FRONT OVERFLOW, BACKSPLASH. DATE FOR RECEIPT OF BIDS, SHALL MAKE WRITTEN REQUEST TO AMERICAN STANDARD "RELIANT +" NO. 2385.406, CHROME PLATED BRASS CONSTRUCTION, 4" CENTERSET, THE ENGINEER FOR INTERPRETATION OR CORRECTION OF ANY ADA COMPLIANT, 0.50 GPM VANDAL RESISTANT AERATOR, LESS POP-UP AND POP-UP HOLE, CERAMIC DISC AMBIGUITY, INCONSISTENCY OR ERROR THEREIN. ANY VALVE CARTRIDGE, ADJUSTABLE HOT LIMIT SAFETY STOP. INTERPRETATION OR CORRECTION WILL BE ISSUED AS AN McGUIRE MANUFACTURING NO. PW2125WC, CHROME PLATED BRASS CONSTRUCTION, ADA COMPLAINT, ADDENDUM BY THE ENGINEER. ONLY A WRITTEN OFFSET GRID STRAINER, 1-1/4" P -TRAP, WITH CLEANOUT, NIPPLE AND ESCUTCHEON, ENTIRE ASSEMBLY INTERPRETATION OR CORRECTION TO BID DOCUMENTS BY IS PREINSULTED (INCLUDING SUPPLY STOP ASSEMBLIES) IN ACCORDANCE WITH ADA REQUIREMENTS. ADDENDUM SHALL BE BINDING. NO BIDDER SHALL RELY UPON McGUIRE NO. H170 -LK, CHROME PLATED ANGLE LOOSE -KEY STOPS, 12" LONG COPPER TUBE RISERS ANY INTERPRETATION OR CORRECTION GIVEN BY ANY OTHER AND ESCUTCHEONS. METHOD. WOODFORD NO. 24, CHROME PLATED HOSE BIBB, WITH POLYCARBONATE HANDLE, H. SUBSTITUTIONS ASSE STD 1011 VACUUM BREAKER. 1. EXCEPT AS PROVIDED BELOW, EACH BIDDER ZURN NO. Z1400 -HD, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, REPRESENTS THAT HIS BID IS BASED UPON THE MATERIALS AND ROUND SCORIATED HEAVY-DUTY SECURED TOP. EQUIPMENT DESCRIBED IN THE BIDDING DOCUMENTS. ZURN NO. ZB1400, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, 2. NO SUBSTITUTIONS FOR OTHER MATERIALS AND ROUND SCORIATED POLISHED BRONZE SECURED TOP, EQUIPMENT WILL BE CONSIDERED UNLESS WRITTEN REQUEST HAS PROVIDE THE FOLLOWING OPTIONS AS REQUIRED FOR FLOOR TYPES: BEEN SUBMITTED TO THE ENGINEER FOR APPROVAL AT LEAST CARPETED FLOORS: OPTION "CM" CARPET MARKER. TEN (10) DAYS PRIOR TO THE DATE FOR RECEIPT OF BIDS. TILED FLOORS: OPTION "T" SQUARE TOP. EACH SUCH REQUEST SHALL INCLUDE A COMPLETE DESCRIPTION ZURN NO. Z-1441, CAST IRON BODY, ABS TAPERED PLUG, ROUND SMOOTH STAINLESS STEEL ACCESS OF THE PROPOSED SUBSTITUTE, THE NAME OF THE MATERIAL OR COVER WITH SECURING SCREW, PROVIDE WITH A CLEANOUT TEE IN VERTICAL PIPING. EQUIPMENT FOR WHICH IT IS TO BE SUBSTITUTED, DRAWINGS, SIOUX CHIEF WATER HAMMER ARRESTER MODEL "HYDRA -RESTER", ASSE 1010, COLD -ROLLED ONE-PIECE CUTS, PERFORMANCE AND TEST DATA OR INFORMATION COPPER CHAMBER, PRESSURIZED AIR CUSHION, GUARANTEED FOR LIFE OF PLUMBING SYSTEM. NECESSARY FOR A COMPLETE EVALUATION. Y INDICATES REQUIRED P.D.I. SIZE. 3. IF THE ENGINEER APPROVES ANY PROPOSED 0s SUBSTITUTION, SUCH APPROVAL WILL BE ISSUED AS AN ADDENDUM FORWARDED TO ALL PARTICIPATING BIDDERS. N 4. IF ANY BIDDER IS UNABLE TO PROCURE WRITTEN APPROVAL OF ANY SUBSTITUTION FROM THE ENGINEER PRIOR TO THE OPENING OF BIDS, THEN HE SHALL BASE HIS BID ON N ITEMS AND SYSTEMS AS SPECIFIED IN BID DOCUMENTS. 5. SUBSTITUTIONS REQUESTED ON THE BID PROPOSAL FORM WHICH ARE PRIOR APPROVED BY THE ENGINEER WILL BE INCORPORATED INTO THE CONTRACT WITH THE SUCCESSFUL BIDDER. 6. REQUESTS FOR ANY SUBSTITUTIONS NOT SUBMITTED AND APPROVED IN ACCORDANCE WITH THE ABOVE INSTRUCTIONS WILL BE DENIED BY THE ENGINEER. 1.3 REGULATORY REQUIREMENTS A. ALL INSTALLATIONS AND EQUIPMENT SHALL BE IN STRICT ACCORDANCE WITH ALL APPLICABLE STATUTES, CODES AND I REGULATIONS OF THE GOVERNMENTAL BODIES HAVING JURISDICTION. B. CONFORM TO 2004 FLORIDA BUILDING CODE. C. CONFORM TO 2004 FLORIDA PLUMBING,MECHANICAL AND FUEL GAS CODES. D. CONFORM TO 2004 FLORIDA FIRE PREVENTION CODE. E. NATIONAL ELECTRIC CODE 2002 EDITION. F. NFPA 54 (NATIONAL FUEL GAS CODE). 1.4 CUTTING AND PATCHING A. Employ skilled and experienced installer to perform cutting and patching. B. Submit written request in advance of cutting or altering elements which effect: 1. Structural integrity of element. 2. Integrity of weather -exposed element 3. Efficiency, maintenance, or safety of element. 4. Visual qualities of sight 5. Work of Owner or separate contractor. PART 2 PRODUCTS 2.1 PIPE HANGERS AND SUPPORTS RT 3 INSTALLATION A. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. B. TORQUE ALL HUBLESS CAST IRON COUPLINGS IN STRICT ACCORDANCE WITH THE MANUFACTURERS RECOMMENDATIONS. UTILIZE COUPLING MANUFACTURERS PRE-SET TORQUE WRENCH. C. PROVIDE NON -CONDUCTING DIELECTRIC CONNECTIONS WHEREVER JOINTING DISSIMILAR METALS. D. ROUTE PIPING IN ORDERLY MANNER AND MAINTAIN GRADIENT. E. INSTALL PIPING TO CONSERVE BUILDING SPACE AND NOT INTERFERE WITH USE OF SPACE. F. GROUP PIPING WHENEVER PRACTICAL AT COMMON ELEVATIONS. G. INSTALL PIPING TO ALLOW FOR EXPANSION AND CONTRACTION WITHOUT STRESSING PIPE, JOINTS, OR CONNECTED EQUIPMENT. H. PROVIDE CLEARANCE FOR INSTALLATION OF INSULATION AND ACCESS TO VALVES AND FITTINGS. I. PROVIDE ACCESS WHERE VALVES AND FITTINGS ARE NOT EXPOSED. COORDINATE SIZE AND LOCATION OF ACCESS DOORS WITH APPROPRIATE ARCHITECTURAL SECTION. J. ESTABLISH ELEVATIONS OF BURIED PIPING OUTSIDE THE BUILDING TO ENSURE PROPER SLOPE AND COVER. K. ESTABLISH ELEVATIONS OF EXISTING BURIED PIPING FOR CONNECTION TO NEW WORK TO ENSURE PROPER SLOPE AND COVER. L. WHERE PIPE SUPPORT MEMBERS ARE WELDED TO STRUCTURAL BUILDING FRAMING, SCRAPE, BRUSH CLEAN, AND APPLY ONE COAT OF ZINC RICH PRIMER TO WELDING. M. EXTEND CLEANOUTS TO FINISHED FLOOR OR WALL SURFACE, LUBRICATE THREADED CLEANOUT PLUGS WITH MIXTURE OF GRAPHITE AND LINSEED OIL. ENSURE CLEARANCE AT CLEANOUT FOR RODDING OF DRAINAGE SYSTEM. N. ENCASE EXTERIOR CLEANOUTS IN CONCRETE FLUSH WITH GRADE. 0. INSTALL EACH FIXTURE WITH TRAP, EASILY REMOVABLE FOR SERVICING AND CLEANING. P. PROVIDE CHROME PLATED RIGID OR FLEXIBLE SUPPLIES TO FIXTURES WITH LOOSE KEY STOPS, REDUCERS, AND ESCUTCHEONS. Q. INSTALL COMPONENTS LEVEL AND PLUMB. R. INSTALL AND SECURE FIXTURES IN PLACE WITH WALL SUPPORTS, WALL CARRIERS AND BOLTS. S. SEAL FIXTURES TO WALL AND FLOOR SURFACES WITH SEALANT AS SPEiCIFIED IN SECTION 07900, COLOR TO MATCH FIXTURE. T. NO PVC PIPING IS ALLOWED IN RATED WALL AND PARTITIONS (USE NO - HUB CAST IRON PIPING). CONTRACTOiR SHALL KEEP AS -BUILT PLANS DURING CONSTRUCTION NDICATING ALL DEVIATIONS FROM CONTRACT DOCUMENTS INCLUDING ALTERED PAPE ROUTING. PLUMBING FIXTURE SCHEDULE TYPE MARK DESCRIPTION PLUMBING FIXTURE CONNECTION SCHEDULE WATER CLOSETS WC -1 FIXTURE AMERICAN STANDARD "CADET" NO. 2898.012, WHITE VITREOUS CHINA, FLOOR MOUNTED, VENT CW HW NOTES FLUSH TANK, 12" ROUGH -IN, 1.6 GALLONS PER FLUSH, 2" GLAZED TRAPWAY, CLOSE - 4" INTEGRAL COUPLED TANK AND LID, TRIP LEVER. SEAT BEMIS TOILET SEAT NO. 1955C, WHITE, HEAVY-DUTY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER, 1-1/2" i 1/2" 1/2' STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. STOP McGUIRE NO. H172 -LK, CHROME PLATED ANGLE LOOSE -KEY STOP, 12" LONG COPPER TUBE RISER v AND ESCUTCHEON. WC -2 FIXTURE AMERICAN STANDARD "CADET RIGHT HEIGHT" NO. 2998.012, WHITE VITREOUS CHINA, FLOOR MOUNTED, o FLUSH TANK, ADA COMPLIANT, 12" ROUGH -IN, 1.6 GALLONS PER FLUSH, 2" GLAZED TRAPWAY, CLOSE - a COUPLED TANK AND LID, TRIP LEVER. SEAT BEMIS TOILET SEAT NO. 1955C, WHITE, HEAVY-DUTY PLASTIC, ELONGATED, OPEN FRONT, LESS COVER, ADD ALTERNATE NO. 1 STAINLESS STEEL POST SELF-SUSTAINING CHECK HINGES. STOP McGUIRE NO. H172 -LK, CHROME PLATED ANGLE LOOSE -KEY STOP, 12" LONG COPPER TUBE RISER o AND ESCUTCHEON. LAVATORIES LL=1 FIXTURE AMERICAN STANDARD "LUCERNE" NO. 0355.012, WHITE VITREOUS CHINA, WALL HUNG, CONCEALED ARM, ADA COMPLIANT, 4" CENTER FAUCET DRILLING, FRONT OVERFLOW, BACKSPLASH. FAUCET AMERICAN STANDARD "RELIANT +" NO. 2385.406, CHROME PLATED BRASS CONSTRUCTION, 4" CENTERSET, U 0 ADA COMPLIANT, 0.50 GPM VANDAL RESISTANT AERATOR, LESS POP-UP AND POP-UP HOLE, CERAMIC DISC VALVE CARTRIDGE, ADJUSTABLE HOT LIMIT SAFETY STOP. DRAIN McGUIRE MANUFACTURING NO. PW2125WC, CHROME PLATED BRASS CONSTRUCTION, ADA COMPLAINT, 01 a OFFSET GRID STRAINER, 1-1/4" P -TRAP, WITH CLEANOUT, NIPPLE AND ESCUTCHEON, ENTIRE ASSEMBLY IS PREINSULTED (INCLUDING SUPPLY STOP ASSEMBLIES) IN ACCORDANCE WITH ADA REQUIREMENTS. STOPS McGUIRE NO. H170 -LK, CHROME PLATED ANGLE LOOSE -KEY STOPS, 12" LONG COPPER TUBE RISERS 0 AND ESCUTCHEONS. HOSE BIBBS HB -1 WOODFORD NO. 24, CHROME PLATED HOSE BIBB, WITH POLYCARBONATE HANDLE, o ASSE STD 1011 VACUUM BREAKER. EXTERIOR CLEANOUT ECO -1 ZURN NO. Z1400 -HD, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, w ROUND SCORIATED HEAVY-DUTY SECURED TOP. FLOOR CLEANOUT FCO -1 ZURN NO. ZB1400, COATED CAST IRON, ADJUSTABLE CLEANOUT, WITH ABS TAPERED -THREAD PLUG, 0��a;w ROUND SCORIATED POLISHED BRONZE SECURED TOP, PROVIDE THE FOLLOWING OPTIONS AS REQUIRED FOR FLOOR TYPES: CARPETED FLOORS: OPTION "CM" CARPET MARKER. TILED FLOORS: OPTION "T" SQUARE TOP. WALL CLEANOUT WCO-1 ZURN NO. Z-1441, CAST IRON BODY, ABS TAPERED PLUG, ROUND SMOOTH STAINLESS STEEL ACCESS O COVER WITH SECURING SCREW, PROVIDE WITH A CLEANOUT TEE IN VERTICAL PIPING. SHOCK ARRESTERS SLY SIOUX CHIEF WATER HAMMER ARRESTER MODEL "HYDRA -RESTER", ASSE 1010, COLD -ROLLED ONE-PIECE COPPER CHAMBER, PRESSURIZED AIR CUSHION, GUARANTEED FOR LIFE OF PLUMBING SYSTEM. Y INDICATES REQUIRED P.D.I. SIZE. I� 3" VTR 4yl- J 3" 2" C,�4 3/4" CW L-1 L -1-N%., \ I I WC -1 WC -1 4" PLUMBING RISER DIAGRAM (ADD ALTERNATE NO. 1). NOT TO SCALE 0 , f PLUMBING FIXTURE CONNECTION SCHEDULE MARK DESCRIPTION WASTE TRAP VENT CW HW NOTES WC -1 WATER CLOSET 4" INTEGRAL 2" 1/2 if -- L-1 LAVATORY 2" 1-1/4" 1-1/2" i 1/2" 1/2' NOTE: ALL FIXTURE CONNECTION SIZES ARE MINIMUM REQUIRED SIZES, REFER TO PLANS FOR LARGER PIPE SIZE REQUIREMENTS. I� 3" VTR 4yl- J 3" 2" C,�4 3/4" CW L-1 L -1-N%., \ I I WC -1 WC -1 4" PLUMBING RISER DIAGRAM (ADD ALTERNATE NO. 1). NOT TO SCALE 0 , f v m N H m a m � LD i v 0 0 C o M a U' w w o U U 0 + N \ b�A� m �M 01 a 0 �� cd 'd o O o '1 w U bA o 0��a;w H O U 0s N ID W 5U xq w N 0 v m N H m a m � o 0 C � M � w o U 0 + N \ b�A� m �M 01 a 0 �� cd 'd o O o '1 w H bA o 0��a;w 41 c 0 v 0 a m C a �i .3 v v m N m L_ 0 v 0 c U m 0 a w U m a N CD 47- L_ 12 `o >. C 0 v m m v v C O U m L a Y N 7 Y O U w 0 m a 0 a rC m v c C C 0 v r DRAWN MLB CHECKED MLB DATE 0 6/13/0 CD SCALE AS NOTED L PROJECT NO. U �= LRG. BOX END PLUMBING SPECS & DETAILS r Y N rx SHEET D Y x U o: a d U w w H O x U o: a d U w x CD G M �N m C 7 oz a 13 M -I Q [� m } a con4 F..� a1w4 o .� 'd OGo v to O U 0 SO O N C O — — �N m C 7 a � v L o � O o c Qy a ^ U a � O �wr L � T_� T f., GENERAL REQUIREMENTS THE GENERAL CONDITIONS AND THE SUPPLEMENTARY CONDITIONS OF THE ARCHITECT SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF ALL EXISTING SITE CONDITIONS. FIELD VERIFY THE EXISTING ELECTRICAL AND TELEPHONE SITE CONDITIONS AND ROUGH—IN (IF ANY). CONTRACTOR TO VERIFY THE INTERCONNECTION REQUIREMENTS OF EACH ELECTRICAL SYSTEM BETWEEN THIS SPACE AND ANY OTHER ATTACHED SPACE. THESE REQUIREMENTS ARE TO BE INCLUDED IN BID. FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS TO PERFORM THE ELECTRICAL WORK AS INDICATED FOR A COMPLETE AND OPERABLE INSTALLATION. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE, WIRING, POWER, AND LIGHTS AS REQUIRED. TEMPORARY SERVICE SWILL MEET ALL NEC AND OSHA REQUIREMENTS CONCERNING GROUND FAULT PROTECTION. UPON COMPLETION OF PROJECT, CONTRACTOR SHALL REMOVE ALL CONDUIT, CONDUCTORS, DEVICES, ETC., ASSOCIATED WITH TEMPORARY SERVICE AND WIRING. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE GENERAL CONTRACTOR A RECORD SET OF PRINTS SHOWING THESE CHANGES. COMPLYING AND PERMITS COMPLY WITH LOCAL CODES, STATE CODES, AND NATIONAL ELECTRICAL CODE (NEC), AND ALL APPLICABLE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AT THE SITE. WHERE THE REQUIREMENTS OF ANY OF THE AUTHORITIES LISTED ABOVE DIFFER FROM THE PLANS OR SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS TAKE PRECEDENCE OBTAIN PERMITS FROM THE AUTHORITIES HAVING JURISDICTION AND TURN OVER TO THE GENERAL CONTRACTOR. MATERIALS ALL MATERIALS USED IN THIS PROJECT SHALL BE NEW UNLESS OTHERWISE NOTED AND SHALL BE LISTED BY THE UNDERWRTH'S LABORATORIES, INC., AS CONFORMING TO ITS STANDARDS WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED. THESE MATERIALS SHALL BEAR THE LISTING MARK OF THE UL SUBMIT MATERIALS LIST AND SHOP DRAWINGS FOR ALL MAJOR EQUIPMENT PROPOSED FOR THIS WORK TO THE GENERAL CONTRACTOR FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS AND SHALL BEAR THE APPROVAL OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED THEM AND THAT THE PROPOSED MATERIALS ARE EQUIVALENT TO OR BETTER THAN THE SPECIFIED MATERIALS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN. CONTRACTOR SHALL PROVIDE AND INSTALL THE SPECIFIED MANUFACTURER AND MODEL NUMBER OF LIGHT FIXTURES AND LAMPS AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE. THE CONTRACTOR SHALL; PROVIDE ADEQUATE INFORMATION ON ANY PROPOSED EXCEPTION TO THE SPECIFIED LIST NO LESS THAN THREE (3) DAYS PRIOR TO BID DATE. PROVIDE MANUFACTURER AND MODEL NUMBER OF PROPOSED EXCEPTIONS AND, IF REQUESTED, PROVIDE CUT SHEET, PHOTOMETRICS, AND SAMPLES. FIXTURE SUBMITTALS NOT AS SPECIFIED AND PROVIDED AFTER BID WITHOUT PRIOR APPROVAL WILL NOT BE ACCEPTED FOR REVIEW. GROUNDING AND BONDING GROUND THE SYSTEM IN ACCORDANCE WITH ARTICLE 250 OF THE LATEST ADOPTED ISSUE OF THE N.E.C. ALL EQUIPMENT, MOTOR, FIXTURE, RECEPTACLE, OR DEVICE TO WHICH CURRENT CARRYING CONDUCTORS ARE CONNECTED SHALL HAVE A SEPARATE GREEN EQUIPMENT GROUNDING CONDUCTOR, SIZED IN ACCORDANCE WITH N.E.C. TABLE 250-95, AND TO BE INSTALLED IN THE RACEWAY AND CONNECTED TO THE DEVICE. ALL GROUNDING OR BONDING CONDUCTORS SHALL BE SIZED AS REQUIRED BY THE NEC AND SHALL BE THWN/THHN INSULATED WITH GREEN COLOR CODING. ALL ELECTRICAL EQUIPMENT ENCLOSURES AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED. SAFETY SWITCHES SAFETY SWITCHES SHALL BE GENERAL DUTY SAFETY SWITCHES WITH 100,000A SHORT CIRCUIT RATING AND SHALL BE LISTED IN ACCORDANCE WITH U.L 98. THE COVER SHALL BE INTERLOCKED SO THAT THE DOOR CANNOT BE OPENED WITH THE HANDLE IN THE 'ON' POSITION, EXCEPT BY THE INTENTIONAL OPERATION OF A CONCEALED RELEASE (DEFEATER) MECHANISM. PROVIDE NEMA 1 ENCLOSURES FOR INTERIOR LOCATIONS AND NEMA 3R ENCLOSURES FOR EXTERIOR LOCATIONS. SAFETY SWITCHES AND DISCONNECTS SHALL BE FUSED (FOR A/C EQUIPMENT AS PER U.L LISTING AND LOCAL CODE REQUIREMENTS) OR NON—FUSED AS INDICATED ON DRAWINGS OR AS REQUIRED BY THE NEC. SWITCHES SHALL BE MANUFACTURED BY GENERAL ELECTRIC, SQUARE D. SIEMENS, WESTINGHOUSE, OR EQUIVALENT. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL SAFETY SWITCHES INDICATING EQUIPMENT SERVED. FUSES TO BE BUSSMAN TYPE, DUAL—ELEMENT, TIME DELAY, TYPE RK5. DIVISION 16 - ELECTRICAL SPECIFICATIONS LIGHT FIXTURES LIGHT FIXTURE SCHEDULE SHOWS REQUIRED TYPE OF FIXTURES ONLY. DETERMINE MODIFICATIONS REQUIRED TO MAKE FIXTURES SUITABLE FOR CEILINGS AS INSTALLED., AND FURNISH FIXTURES ADAPTED TO THE CEILING USED. FIXTURES SHALL BE U.L APPROVED. THIS CONTRACTOR SHALL PROTECT THE FIXTURES AND LAMPS, AND SHALL REPLACE BROKEN PARTS. 'ALL LENSES AND LOUVERS IN ANY AREAS SHALL BE CLEANED AFTER ALL TRADES HAVE COMPLETED THEIR WORK IN THAT AREA. RACEWAY ALL RACEWAY ROUTED CONCEALED ABOVE CEILING OR IN WALL SHALL BE EMT. ALL CONDUIT EXPOSED TO THE PHYSICAL DAMAGE OR OUTSIDE SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT. MINIMUM SIZE OF RACEWAY SHALL BE 1/2'. UNDERSLAB OR UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC CONDUIT. SIZE CONDUIT PER N.E.C. FOR ENCLOSED WIRING. FITTINGS SHALL BE APPROVED AND U.L LISTED FOR THE RACEWAY INSTALLED. PROVIDE PULLSTRINGS IN ALL EMTPY CONDUITS. ALL CONDUIT TERMINATING IN OUTLETS, JUNCTION OR PULL BOXES, AND CABINETS MUST TERMINATE WITH A LOCKNUT AND BUSHING, EXCEPT AT EXPOSED CAST BOXES WHERE THEY MAY BE OMITTED. RIGID CONDUIT SHALL BE INSTALLED WITH DOUBLE LOCKNUTS AND BUSHING. COUPLINGS, CONNECTORS, AND FITTINGS FOR EMT SHALL BE STEEL SETSCREW. FLEXIBLE METAL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHTING FIXTURES, FIXED APPLIANCES AND MOTORS WHERE FLEXIBILITY IS REQUIRED FIXTURE WHIPS MAY BE 1/2' TO 3/8' TO INDIVIDUAL FIXTURES AND ALL OTHER SHALL BE 1/2'. PVC CONDUIT SHALL BE INSTALLED WITH FACTORY ELBOWS AND FITTINGS. USE ONLY APPROVED SOLVENT GLUE FOR THE CONDUIT AND FITTINGS. FIELD BENDING OF PVC CONDUIT MAY BE PERFORMED ONLY WITH THE CONDUIT MANUFACTURER'S "HOT BOX' APPROVED BENDERS. ALL CONDUCTORS MUST BE IN A RACEWAY. NO BX OR ROMEX ALLOWED. MX TYPE IS ALLOWED WHEN ITS' USE IS PERMITTED BY THE AUTHORITIES HAVING JURISDICTION. CONDUCTORS ALL CONDUCTORS SHALL BE #12 COPPER (MINIMUM) WITH THHN/THWN INSULATION AND SHALL CONFORM TO THE CURRENT ISSUE OF THE NEC. ARTICLES 300 AND 310, AND SHALL MEET ASTM SPECIFICATIONS. ALL CONDUCTORS SHALL BE NEW FREE OF KINKS AND OTHER DEFECTS WHEN INSTALLED. MINIMUM WIRE SIZE SHALL BE NO. 12 (EXCEPT NO. 14 FOR CONTROL WIRING) AND SHALL BE SOFT DRAWN COPPER, SOLID WITH THWN/THHN INSULATION IN SIZES THROUGH NO. 10 AND STRANDED WITH THWN/THHN INSULATION FOR NO. 8 AND LARGER. INSULATION SHALL BE SUITABLE FOR 600 VOLTS AND MUST BEAR THE CONDUCTOR SIZE, TYPE OF INSULATION, AND THE MANUFACTURER'S NAME STAMPED AT REGULAR INTERVALS. COLOR CODING SHALL BE AS FOLLOWS: SYSTEM VOLTAGE: 240/120 VOLT PHASE A BLACK PHASE B RED PHASE C BLUE NEUTRAL WHITE GROUND GREEN COLOR CODE SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM FROM MAIN SWITCH THROUGH ALL BRANCH CIRCUITRY. SUPPORTS PROVIDE ALL SUPPORTS FOR MATERIAL AND EQUIPMENT. PROVIDE STRAIN RELIEFS FOR OVERHEAD DROP SERVICE CORDS. WIRING A COMPLETE SYSTEM OF CONDUCTORS SHALL BE INSTALLED FOR ALL FEEDERS, BRANCH CIRCUITS, AND CONTROL CIRCUITS AS NOTED ON THE PLANS. NO WIRE IS TO BE INSTALLED IN RACEWAY UNTIL THE ENTIRE RACEWAY SYSTEM IS COMPLETE AND THEN ONLY WITH THE USE OF AN APPROVED WIRING LUBRICANT. BRANCH CIRCUIT SIZES ARE NOTED ON THE PLANS AND MUST BE CONTINUOUS WITHOUT REDUCTION IN SIZE THROUGHOUT THEIR LENGTH BETWEEN FIXTURE, EXCEPT WHERE CONNECTING TO FIXTURES. BRANCH CIRCUITS EXCEEDING 70 FEET IN TOTAL LENGTH SHALL BE A MINIMUM OF NO. 10 AWG TO THE FIRST OUTLET OR FIXTURE (THIS DOES NOT APPLY TO CIRCUITS WITH LARGER THAN NO. 12 CONDUCTORS ALREADY INDICATED ON PLANS). TELEPHONE PREWIRING PROVIDE ALL NECESSARY WIRING, BOXES AND RELATED ACCESSORIES REQUIRED BY LOCAL TELEPHONE COMPANY FOR COMPLETE PREWIRED UNIT INSTALLATON OF TELEPHONE SERVICE TO TELEPHONE COMPANY INTERFACE. WIRING DEVICES THE FOLLOWING LISTED HUBBELL DEVICES MAY BE THE PRODUCT OF EAGLE, P do S, OR ARROW—HART, BUT MUST BE EQUIVALENT TO THE DEVICES LISTED AND MUST BE IDENTIFIED IN THE SUBMITTALS. ALL DEVICES SHALL BE GANG MOUNTED WHERE POSSIBLE. SWITCHES: SINGLE POLE, 20 AMPERES, 120/277 VOLT. CS120—W RECEPTACLES: DUPLEX, NEMA 5-20R, 20 AMP, 125 VOLT. CR20—W THE COLOR OF ALL WIRING DEVICES SHALL BE IVORY (FIELD VERIFY TO MATCH EXISTING COLOR) UNLESS OTHERWISE NOTED OR AS APPROVED/DIRECTED BY THE ARCHITECT. COVER PLATES SHALL BE PLASTIC, COLOR TO MATCH THE ASSOCIATED DEVICE. EQUIPMENT CONNECTIONS THE ELECTRICAL CONTRACTOR SHALL MAKE ALL POWER CONNECTIONS TO EQUIPMENT INCLUDING ALL THE ONES INSTALLED BY THE HVAC AND PLUMBING CONTRACTORS. ALL CONTROL WIRING NOT INDICATED ON THE PLANS WILL BE THE RESPONSIBILITY OF OTHER TRADES. THE ELECTRICAL CONTRACTOR MUST OBTAIN ROUGH—IN INFORMATION FROM OTHER CONTRACTORS AND VERIFY THE ACTUAL PURCHASED EQUIPMENT PRIOR TO INSTALLATION. VERIFY THE THERMAL CONDITIONS OF THE EQUIPMENT BASED ON NAMEPLATE DATA AND CONNECT AS THE LISTING REQUIREMENTS ARE STATED USING THE SPECIFIED MATERIALS. ALL POWER AND CONTROL CIRCUITS FOR ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL CONNECTIONS ARE BASED ON THE DESIGN AS INDICATED WITHIN THE CONTRACT DOCUMENTS. THE DIVISION 16 TRADESMAN SHALL VERIFY ALL PURCHASED EQUIPMENT THAT REQUIRES ELECTRICAL CONNECTION WITH THE RESPONSIBLE CONTRACTOR OR VENDOR PRIOR TO ELECTRICAL ROUGH—IN. ANY DEVIATIONS IN EQUIPMENT ROUGH—IN REQUIREMENTS FROM THE CONTRACT DOCUMENTS SHALL BE CONSIDERED A COORDINATION ITEM THAT THE ELECTRICAL TRADESMAN SHALL DISCUSS WITH THE OTHER TRADES INVOLVED. APPARATUS IDENTIFICATION PANELBOARDS, CIRCUIT BREAKERS, ;DISCONNECT SWITCHES AND OTHER APPARATUS USED FOR THE OPERATION AND CONTROL OF CIRCUITS, APPLIANCES AND EQUIPMENT SHALL BE PROPERLY IDENTIFIED BY MEANS OF ENGRAVED LAMINATED PLASTIC DESCRIPTIVE NAMEPLATES MOUNTED ON THE APPARATUS USING PERMANENT CONTACT CEMENT. PROVIDE TO THE OWNER UPDATED PANELBOARD DIRECTORIES UPON COMPLETION OF CONSTRUCTION. GUARANTEE MATERIALS, EQUIPMENT, AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE DEVICE MOUNTING HEIGHTS ALL MOUNTING HEIGHTS ARE TO THE CENTER OF DEVICE, UNLESS SHOWN OR NOTED OTHERWISE: SWITCH: 48' A.F.F. RECEPTACLE: 18' A.F.F. OR AS NOTED TELEPHONE. ON CENTERLINE OF ADJACENT DEVICES (RECEPTACLES). DISCONNECT SWITCH: NOT LESS THAN 24' A.F.F. OR A.F.G. AND NOT MORE THAN 6'-5' A.F.F. OR A.F.G. TO TOP OF HANDLE, UNLESS SHOWN OR NOTED OTHERWISE ELECTRICAL ABBREVIATIONS A AMPERE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE C CONDUIT C.B. CIRCUIT BREAKER E EXISTING EF EXHAUST FAN EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER FF FINISHED FLOOR GFI GROUND FAULT CIRCUIT INTERRUPTING GND GROUND KAIC KILO—AMPERES OF INTERRUPTING CURRENT M.C.B. MAIN CIRCUIT BREAKER S/N SOLID NEUTRAL TTB TELEPHONE TERMINAL BOARD TYP. TYPICAL XFMR TRANSFORMER V VOLT WP WEATHERPROOF OR NEMA 3R ELECTRICAL SYMBOL LEGEND ® EXIT FIXTURE — SINGLE OR DOUBLE FACE DIRECTIONAL ARROWS AS SHOWN ON PLANS G WALLPACK, SEE LIGHT FIXTURE SCHEDULE O HIGH BAY OR DOWNLIGHT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE COMBINATION BATTERY OPERATED EMERGENCY / EXIT LIGHT FIXTURE $ SWITCH — SINGLE POLE, +48' A.F.F. $�r ROTARY TIME SWITCH, INTERMA11C #FD60MC—IVORY OR EQUAL $3 THREE WAY SWITCH, +48" A.F.F. i $3T 3—WAY ROTARY TIME SWITCH, INTERMATIC #FD32H—IVORY OR EQUAL qp DUPLEX RECEPTACLE, NEMA 5-20R DUPLEX RECEPTACLE MOUNTED 48' A.F.F. ® 30A, 250V RECEPTACLE, 48' A.F.F. JUNCTION BOX I PANELBOARD, 240/12OV, SEE PANELBOARD SCHEDULE D NEMA 3R METER BASE AND SOCKET. METER BY POWER CO. /'-RPA-1,3,5 HOMERUN TO PANEL (ONE ARROW PER CIRCUIT) CONDUIT CONCEALED IN WALLS CONDUIT EXPOSED 3 ��- CONNECTION TO EQUIPMENT I r7lj FUSED DISCONNECT SWITCH, S/N, 2 — POLES, 60 — FRAME SIZE, 40 — FUSE SIZE 3 2 40 0 GAME DOOR OPENER CONTROL PAD, +48' A.F.F. RAG MM- ALL INDICATED MOUNTING HEIGHTS ARE TO THE BOTTOM OF DEVICE UNLESS OTHERWISE SHOWN OR NOTED. GENERAL ELECTRICAL NOTES 1. THE USE OF ANY PROCESS INVOLVING ASBESTOS OR PCB, AND THE INSTALLATION OF ANY PRODUCT, INSULATION, COMPOUND OF MATERIAL CONTAINING OR INCORPORATING ASBESTOS OR PCB, IS PROHIBITED. THE REQUIREMENTS OF THIS SPECIFICATION FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM SHALL BE MET WITHOUT THE USE OF ASBESTOS OR PCB. 2. AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. 3. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH NEC 2005 AND ALL OTHER CODES AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION. 4. IT IS THE INTENT THAT THE WORK INDICATED, ON THESE DRAWINGS BE PERFORMED IN A WORKMANLIKE MANNER AND BE COMPLETE IN EVERY RESPECT FOR OCCUPANCY BY THE OWNER. TOLERANCES TYPICALLY 1/8" IN 10'4" U.N.O. 5. INSTALL ALL MATERIALS AND FIXTURES PER MANUFACTURER'S RECOMMENDATIONS. 6. FIELD VERIFY ALL DIMENSIONS AND ROUGH—IN ' DIMENSIONS WITH ACTUAL CONDITIONS. 7. ALL SYSTEMS AND CONSTRUCTION TO BE COMPLETE IN EVERY RESPECT AND OPERATIONAL FOR THE PURPOSE FOR WHICH THEY WERE INTENDED. PROVIDE OWNER WITH ALL WARRANTIES / MANUALS FOR MATERIALS, SYSTEMS, ETC. 8. PROVIDE ELECTRICAL SYSTEM COMPONENTS AND ITEMS AS REQUIRED. ELECTRICAL CONTRACTOR TO PROVIDE ADDITIONAL DRAWINGS FOR PERMIT AND ALL LABOR, MATERIALS, AND ANY MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETED SYSTEM READY FOR OPERATION DISCLAIMER NOTICE: THIS DOCUMENT CONTAINS PRIVILEGED AND CONFIDENTIAL INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY 'AZ POWER SYSTEMS' FOR THE USE OF THE INTENDED RECIPIENT, AND FOR AN INTENDED PURPOSE ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN CONSENT OF 'AZ POWER SYSTEMS' IS STRICTLY PROHIBITED. OM w im =L, w O O �7) LIGHT FIXTURE SCHEDULE BUS AMPS: 225 PHASE: 1 LUG LOCATION: BOTTOM MAIN AMPS: 150 M.C.B. WIRE: 3 MOUNTING: SURFACE CIRCUITS: 42 IBALLAST DATA DESCRIPTION LIGHT FIXTURE DATA LAMP DATA SERVICE: 240/120 V OPTIONS: NEMA 3R TYPE: SQUARED, NQOD AIC RATING: 10K KVA QTY. TYPE VOLTS KVA CB CKT BUS CKT. CB ID MANUFACTURER MODEL NUMBER TYPE WATTS Y.....: TG OTH LOAD €..W.». .....WW. »..... �....»»..._ W` .............W �.».. _ . »W... W ... ._....... » ... �_._ �..._. ».._.... �»..._ »._ ... �...»»._W».. OTHER ; ...LTG REC LOAD SERVED POLE TRIP N0. A B N0. TRIP POLE EC j L W..... »....... ............._ ..._..._ ...W... »..... �.. 2 1 T 120 4' HEAVY-DUTY FLUORESCENT STRIP, 2 -LAMP, HIGH GLOSS BAKED ENAMEL E 1.46 LTG, EXTERIOR .20........E _ 1 46 2.... 0 LTG, EXTERIOR A LITHONIA UNS 2 32 120 FLUORESCENT 32 2 ELECTRONIC " "^ ` -....0 26:0 36 RECEPT , LTG., HANGAR 20 1 3 4 20 1 RECEPT , LTG., HANGAR m. 0.36 z....0 26. FINISH nmr « »»......,r_........ _.. f ..... .... ......... .. :» 1.38 r _.. ., .»» _.. »w , »»».... »»» .. OTORIZED AIRCRAFT DOOR 2HP 20 2 _5 6.W »?0 2::,::, .MOTORIZED »AIRCRAFT DOOR (2HP) » 1.38 , : : M ...._ W,»_.»....... __ .. _ W...__W 1 3 f 6' ABOVE THE MIIRROR »... €..._.. W .._..^.»...W.».....r »___»__.».»__ » .». _...W »» ---' --- 7 8 F20T12 f 20 2 ELECTRONIC 120 2 FLUORESCENT WALL BRACKET, --- --- ----- CD22OW-120 E 1.38 C2 DAYBRITE »,.r.:._ . r ::... :.�.,. . 0.26 0.36 1 RECEPT., HANGAR 2U E. _ �._u ....9_LL..,...... uu.. ....,_.�� _ .. 20 ; 2 MOTORIZED AIRCRAFT DOOR „ 2HP)....... ...... W . _ uu u .,1.38 FLUORESCENT € m:::..»....._ _ W.w. _......W... W_u.W..� ......uuu.»_..... _LL »...-._LL._LL..».. u € _. 11 12 --- --- - m....... 20 1 .38 € .... ..... _ _ ......... SPARE m. ..,.. ..,,.r ...mw. ..... I , 100 1 HPF � 120 DIE-CAST ALUMINUM WALLPACK, LAMP INCLUDED, FINISH SELECTION BY .._ ...» -�- <,• � ��� H LITHONIA TWA 100A 120 SF LPI METAL HALIDE € 1.38 £ MOTORIZED AIRCRAFT DOOR (2HP ., 20 2 13 14 20 1 RECEPT., LTG., HANGAR, RESTROOMS 0.54 0.305 € FUSED, INSTAL. AT N9'-0' A.F.G. TO BOTTOM »... w ...., »» , . ,._ » , u u.. MEDIUM BASE€ _ »� 8 ----- 15 1 fi 20 1 SPARE ................! ......... . ...._ ----. m :. ...:::::: .. ;:::. .. ......,...E .. __.. ,.... ....................... ... .::.:... f 17 18 20 1 SPARE .............:....:....::.......... .»,.. ,, __ . _„ ......._ ..,,.....__. 120 LIGHT DIE-CAST ALUMNINUM, GASKETED, 0.05 0.90 I RECEPT., LTG., HANGJAR, RESTROOMS 20 f HPF INTERMEDIATE FLOOD �,�.:...._�,,,,,,,,,,,,,,,,;,,,,,,;,;,,,,,.:::.,..__.,,,,,,,,,.._.,:,,,,,,,......__,:..,,,,,,... ww__�.w„�,.:»,»,.�,w.k,,.._.�.,,..._.�..,,,,,.._:...,,,,,...�..,,�.__,,,,,,..__ .,,,,...»».�» __�.�._ ...» »..:..,,,.»..:..,,:,,,,...,::..,,,,,...._. " K DAYBRITE NITE BRITES FU 400 M 120 ISF WRABH GG1 METAL HALIDE E 400 1 f € 0.52 # LTG., HANGAR .2a. -`.... 1..... _ ....9 20.:.. 20... _ 1. .. SPARE ...... i f DARK BRONZE POLYESTER FINISH, INSTALL AT N14 -6 A.F.G. TO BOTTOM €...... �s...,_...._»»....v� 3.22 < MOTORIZED AIRCRAFT DOOR 5HP) 50 I 2 mm ...::: �» ..........,. _ »._ ..., _ _»....... ...». E m._ :..... £...::m ; ...._»»..:..... 22 20 1 SPACE»..........».. CCAXL-I-G-W-H LED 120 COMBINATION EMERGENCY BATTERY FIXTURE AND SINGLE GREEN -- XEM MCPHILBEN € .W......23 . �. 24._ .»W .................... ........» ..._.»...»........W..».._ MR16 HALOGEN FACE EXIT LIGHT, WHITE HOUSING, EMERGENCY NI -CAD BATTERY 1.20 ..:..... :.... GARAGE DOOR OPENER (1/2HP) 20 f 1 25 26 r _ 'SPACE .. _ W . ... ...... ._.....4___. Em 1. PROVIDE ENERGY SAVING LAMPS AND BALLASTS. 2. ALL EXIT AND BATTERY PACK LIGHT FIXTURES SHALL BE CONNECTED AHEAD OF ROOM LIGHT SWITCHING. 3. EQUAL MANUFACTURERS TO BE LITHONIA, UGHTOUER AND COOPER. 3. VERIFY AND COORDINATE EXACT FIXTURE MOUNTING HEIGHTS WITH THE OWNER PRIOR TO ROUGH -IN. FEEDER / CONDUIT SCHEDULE ID MARK WIRE 51ZE (AHS) EEROM SIZE (AHS) CONDUIT 51ZE ® 2010 #10 5/4' ® 2#8 #10 5/4' GENERAL ELECTRICAL PLAN NOTES € 29 30 THEY PENETRATE (TYP.). 2. ALL HOMERUNS TO BE 110 THHN/THWN CU. IN 3/4' EMT C. MINIMUM, UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE 3. ALL EXIT AND EMERGENCY BATTERY BALLASTS OF LIGHT FIXTURES TO BE CONNECTED € AHEAD OF LOCAL SWITCHING. € 31 40 32 OR EQUAL INSTALL AS HIGH AS POSSIBLE 5. ALL RECEPTACLES AND ELECTRICAL DEVICES WITHIN AIRCRAFT HANGAR SPACE TO BE INSTALLED AT +48' A.F.F. TO THE BOTTOM OF EACH DEVICE ALL CONDUIT AND FITTINGS ROUTED BELOW 18' A.F.F. TO BE EXPLOSIONPROOF TYPE KEY NOTES: PROVIDE 30A, 24OV, 14, NEMA L6-30 TWISTLOCK RECEPTACLE IN SURFACE MOUNTED METAL BACKBOX AND TYPE SJO 30/3 CORD WITH PLUG FOR THE AIRCRAFT OVERHEAD DOOR MOTOR. INSTALL RECEPTACLE AT +48' A.F.F. (TYP. OF 4). PROVIDE A SURFACE MOUNTED 4'X4' JUNCTION BOX ABOVE GARAGE DOOR OPENING TO SERVE GARAGE DOOR OPENER. f I PROVIDE A SURFACE MOUNTED GARAGE DOOR PUSHBUTTON CONTROLS AT +48' A.F.F. TO ....:........ THE BOTTOM OF CONTROLS. PROVIDE ALL NECESSSARY INTERCONNECTIONS TO THE 35 L%l 36 PROVIDE A WALL SURFACE MOUNTED 60A, 24OV, 10, S/N NEMA 1 OVERHEAD AIRCRAFT HANGAR DOOR MOTOR DISCONNECT SWITCH AT +60' A.F.F. TO THE BOTTOM OF SWITCH. . f .... 37 38 ....... ........ ........... .. ....... ! .. ..................................._............ ........ ............... 39 40 ........ ......... .. 41 42 PROVIDE: CONNECTED KVA 2.52 1 4.57 18.68 DEMAND FACTOR 1.0 HACR TYPE CIRCUIT BREAKERS SERVING HVAC EQUIPMENT DEMAND KVA 2.52 5.71 € 9.34 UPDATED TYPEWRITTEN DIRECTORY TOTAL DEMAND KVA 17.57 ? SBX SURGE ARRESTER DEMAND AMPS 73.2 GENERAL ELECTRICAL PLAN NOTES 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.). 2. ALL HOMERUNS TO BE 110 THHN/THWN CU. IN 3/4' EMT C. MINIMUM, UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE 3. ALL EXIT AND EMERGENCY BATTERY BALLASTS OF LIGHT FIXTURES TO BE CONNECTED AHEAD OF LOCAL SWITCHING. 4. PROVIDE AN EXTERIOR WAIL FLUSH MOUNTED PHOTOCELL AT THE NORTHWEST CORNER OF ' ' 'H'. INTERMATIC K4321C TYPE K AND 0 LIGHT Fl i� THIS BUILDING FOR CONTROL F FIXTURES OR EQUAL INSTALL AS HIGH AS POSSIBLE 5. ALL RECEPTACLES AND ELECTRICAL DEVICES WITHIN AIRCRAFT HANGAR SPACE TO BE INSTALLED AT +48' A.F.F. TO THE BOTTOM OF EACH DEVICE ALL CONDUIT AND FITTINGS ROUTED BELOW 18' A.F.F. TO BE EXPLOSIONPROOF TYPE KEY NOTES: PROVIDE 30A, 24OV, 14, NEMA L6-30 TWISTLOCK RECEPTACLE IN SURFACE MOUNTED METAL BACKBOX AND TYPE SJO 30/3 CORD WITH PLUG FOR THE AIRCRAFT OVERHEAD DOOR MOTOR. INSTALL RECEPTACLE AT +48' A.F.F. (TYP. OF 4). PROVIDE A SURFACE MOUNTED 4'X4' JUNCTION BOX ABOVE GARAGE DOOR OPENING TO SERVE GARAGE DOOR OPENER. PROVIDE A SURFACE MOUNTED GARAGE DOOR PUSHBUTTON CONTROLS AT +48' A.F.F. TO THE BOTTOM OF CONTROLS. PROVIDE ALL NECESSSARY INTERCONNECTIONS TO THE GARAGE DOOR OPENER MOTOR. L%l LOCA11ON OF PANEI"D AND METERING. PROVIDE A WALL SURFACE MOUNTED 60A, 24OV, 10, S/N NEMA 1 OVERHEAD AIRCRAFT HANGAR DOOR MOTOR DISCONNECT SWITCH AT +60' A.F.F. TO THE BOTTOM OF SWITCH. ...... ..... . ........ ......... ...... ........... .. ... ......... .. ...... ......... f = SBX-10:12, SOUTHEAST RAMP - PHASE 2A LARGE BOX HANGAR WEND UNIT - ELECTRICAL FLOOR PLAN SCALE: 1 /8" =1'-0" SBX-13:15` € ................ ._ ............. DIS.CLAII .E.R. w TIC.. THIS DOCUMENT CONTAINS PRIVILEGED AND CONFIDENTIAL INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY 'AZ POWER SYSTEMS' FOR THE USE OF THE INTENDED RECIPIENT, AND FOR AN INTENDED PURPOSE ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN CONSENT OF 'AZ POWER SYSTEMS' IS STRICTLY PROHIBITED. ull ICU. IN2'C. CS TRANSFORMER ti C' y! Power Systems Boobiml Enptn"riey a Coo Ing R. License 160953 11655 Swift Water Circle Orlando, FL 32817 Phone/Fox.- 407.243 6020 azpowersystemsObellsouth. net .. .. ...... ..... �u._W EXISTING HANGAR ......_._ EXISTING HANGAR L GDENERAL ELECT GAL NOTES: 1: PROPOSED F7. HANGAR EL. 28.5 SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE ® WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.). 2. ALL HOMERUNS TO BE #10 THHN/THWN CU. IN 3/4" EMT C. MINIMUM, .. .. ...... ..... �u._W EXISTING HANGAR ......_._ EXISTING HANGAR L GDENERAL ELECT GAL NOTES: 1: ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE WIRE SIZE (AWS) SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE ® WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.). 2. ALL HOMERUNS TO BE #10 THHN/THWN CU. IN 3/4" EMT C. MINIMUM, UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE. 3. ALL ELECTRICAL EQUIPMENT SHOWN DASHED IS EXISTING TO REMAIN, UNLESS SHOWN OR NOTED OTHERWISE (TYP.). 4. FINAL LOCATION OF POWER AND TELECOMMUNICATIONS OUTLETS TO BE COORDINATED WITH THE OWNER PRIOR TO ROUGH—IN. 5. ALL TERMINATED ENDS OF EMTPY UNDERGROUND OR STUBBED—UP CONDUIT TO BE CAPPPED AND SEALED. PROVIDE TWO NYLON PULLSTRINGS IN EACH CONDUIT FOR FUTURE CABLE PULLS. 5. ALL SECONDARY CONDUIT TO BE BURIED A MINIMUM OF 24" BELOW FINISHED GRADE WITHIN TRAFFIC RATED AREAS, AND 18" BELOW FINISHED GRADE IN NON—TRAFFIC OR LANDSCAPE AREAS (TYP.). 6. PRIMARY CONDUIT BURIAL DEPTH PER POWER CO'S REQUIREMENTS OR 36" BELOW FINISHED GRADE (TYP.). li__-�:>REMOVE EXISTING PORTION OF BURIED PRIMARY CONDUIT AND REROUTE TO THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER. 2 PROVIDE A METAL STAKE TO IDENTIFY THE LOCATION OF BURIED 2" PRIMARY CONDUIT FOR FUTURE USE. 3 > PROPOSED LOCATION OF POWER CO'S. 240/12OV, 10 TRANSFORMER TO SERVE BUILDING(S) AS SHOWN. PROVIDE 2" SECONDARY CONDUIT FROM THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER TO SERVE BUILDING PANELBOARD. 5 PROVIDE 2'X3' GRADE MOUNTED POLYCRETE PULLBOX (TYP.). PROVIDE TWO (2) 2" AND FOUR (4) 3" BURIED CONDUITS BETWEEN PULLBOXES AS SHOWN. 7 PROVIDE TWO (2) 2" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF TELEPHONE TERMINAL BOARD. STUB—UP +18" A.F.F. 8 ,> PROVIDE THREE (3) 1" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF GATE CONTROL DEVICES AS DIRECTED BY AIRPORT AUTHORITY AND THE OWNER. 9 EXISTING POWER CO.'S PRIMARY CONDUIT TEMRINATION. 10 PROVIDE A WEATHERPROOF CAST OUTLET BOX AND WATERTIGHT FLEXIBLE CONNECTION TO THE EXTERIOR ILLUMINATED SIGN, CONTROLLED BY A PHOTOCELL. VERIFY EXACT LOCATION WITH THE OWNER PRIOR TO ROUGH—IN. SERVICE TO BE PROVIDED VIA 20A/1 P CIRCUIT BREAKER IN PANELBOARD 'C2-1', CIRCUIT 31. FEEDER / CONDUIT SCHEDULE ID MARK WIRE SIZE (AWS) GROUND SIZE (AWG) CONDUIT SIZE ® 2010 *10 S/4" CRAPHIC SCALE 30 0 15 30 60 120 IN FEET) > INCH = 60 FT. FONARYOV, P.E. Power Systems Electrical Engineering & Consulting fZ. License /60953 11655 Swift Water Circle Orlando, fZ 32817 Phone/Fox: 407.243.6020 azpowersystems®bellsouth.net 0 b cz Cz I~ co 0 �E-1 a a � C (� Ha W 0 U) b 0 cid DRAWN AEZ CHECKED AEZ DATE JUNE 15, 2006 SCALE AS NOTED PROJECT NO. 24015.3 PHASE 2A HANGARS ELECTRICAL SITE UTILITIES SHEET ES -2.0