Loading...
6320-6371 Tarmac Way - BC07-000148 (SANFORD AIRPORT AUTH) (LG BX HANGAR) (A)00 ---Mo PERMIT AD 004 CONTRACTOR ADDRESS PHONE NUMBER PROPERTY OWNER ADDRESS PHONE NUMBER ELECTRICAL CONTRACTOR MECHANICAL CONTRACTO { PLUMBING CONTRACTOR MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE MISCELLANEOUS CONTRACTOR PERMIT NUMBER FEE PERMIT* V DATE O '110(w PERMIT DESCRIPTION PERMIT VALUATION 3a Ov SQUARE FOOTAGE CA GENERAL CONDITIONS AND NOTES C IT 15 THE INTENT OF THE ARCHITECT THAT TH15 WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS OF THE BUILDING AUTHORITIES FOUNDATIONS HAVING JURISDICTION OVER TH15 TYPE OF CONSTRUCTION AND OCCUPANCY. ALL CONTRACTORS SHALL DO THEIR WORK IN I. 5U55URFACE SOIL CONDITIONS INFORd'IATION 15 NOT AVAILABLE. FOUNDATION DESIGN 15 BASED ON AN ASSUMED ALLOWABLE CONFORMANCE WITH ALL APPLICABLE CODES AND REGULATIONS. BEARING PRESSURE OF 2000 P5F AND SHALL BE VERIFIED BY A GEOTECHNICAL ENGINEER REGI5TRERED IN THE STATE OF 2., THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT THE J05517E PRIOR TO COMMENCING WORK CONTRACTOR FLORIDA. CONTRACTOR OR OWNER TO PROVIDE A$ REQUIRED BY BUILDING OFFICIAL. SHALL REPORT ALL DISCREPANCIES IN THE DRAWINGS AND EXISTING CONDITIONS TO THE ARCHITECT PRIOR TO COMMENCING 2. ALL REQUIREMENTS FOR 51TE PREPARATION AND SOIL COMPACTION SPECIFIED IN THE SOILS REPORT SHALL BE FOLLOWED WORK UNLESS ADDITIONAL MORE STRINGENT REQUIREMENTS ARE SPECIFIED. NOTIFY ARCHITECT IF FOUNDATION CONDITIONS 3. CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD IN THE WORK ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, ENCOUNTERED DIFFER FROM 501L5 EXPLORATION INFORMATION MADE AVAILABLE TO THE CONTRACTOR HANGERS, SLAB DEPRESSIONS, AND PITCHES AS MAY BE REQUIRED TO ATTACH AND ACCOMMODATE OTHER WORK 3. 501L SHALL BE COMPACTED TO A MINIMUM OF 959- OF MAXIMUM MODIFIED PROCTOR DENSITY. 4. THESE DOCUMENTS, AS INSTRUMENTS OF SERVICE, ARE THE PROPERTY OF THE ARCHITECT AND MAY NOT BE USED OR 4. ALL FOOTINGS SHALL BE CENTERED UNDER THE COLUMN OR WALL ABOVE UNLE55 NOTED OTHERWISE. ON 0TH SIDES OF THE WALL IN P55 THE WALL 15 FULLY BRACED BY THE 2004 FLORIDA BUILDING CODE 2004 FLORIDA FIRE CODE WIND SPEED 120 MI 5. REPRODUCTED WITHOUT EXPRESSED WRITTEN CONSENT OF THE ARCHITECT. ALL DETAILS AND 5ECTION5 SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO 5. BACKFILL AGAINST A WALL SHALL BE PLACED EVENLY B CONTRACTOR FOR LATERAL PRESSURE. SUCH BRACING, INCLUDING ITS DESIGN, IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR SHALL REMAIN IN PLACE UNTIL AFTER THE FLOOR SLAB OR OTHER STRUCTURAL ELEMENT BRACING THE WALL HAS BEEN 13, ANY SIMILAR SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT DETAIL IS SHOWN. THE CONTRACTOR SHALL CONSULT THE ARCHITECT IF THERE 15 ANY UNCERTAINTY REGARDING THE INTENT OR APPLICATION OF A DETAIL OR CONSTRUCTION PROVIDED BY THE OWNER BEFORE PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS OR OTHER CONDITIONS OF LIMITATIONS A7 THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS AND CONSTRUCTED TO THE SATISFACTION OF THE ARCHITECT. 6, ISSUE. ALL DIMENSIONS AND ELEVATIONS SHOWN SHALL BE FIELD VERIFIED BY THE CONTRACTOR PRIOR TO CONSTRUCTION. CAST IN PLACE CONCRETE 1, TH15 STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH AND MEE75 THE REQUIREMENTS OF SECTION 1609, 2004 EDITION OF I. ALL CONCRETE SHALL HAVE THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH AT 28 DAYS: 16. A DE51GNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPEMNT SHALL BE DETERMINED BY THE OWNER CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, STORING, PLACING AND PROTECTING FROM THE FLORIDA BUILDING CODE. IT IS DESIGNED AS FOLLOWS TO WITHSTAND THE FOLLOWING LOADS: PRIOR TO PLACEMENT OF CONCRETE. FOR BEAMS, LAP BOTTOM STEEL AT THE SUPPORT AND TOP STEEL OVER THE MIDSPAN, UNLE55 NOTED OTHERWISE. SLAB ON GRADE AND FOOTINGS 3000 P51 11. • 120 MPH WIND LOAD5 WITH SHAPE FACTORS. • EXPOSURE B WIND LOADS 2. REMAINING CONCRETE 3000 P51 ALL CONCRETE SHALL HAVE A SLUMP OF 4' .PLUS OR MINUS 1', AND HAVE 2 TO 4% AIR ENTRAINMENT5, AND A MAXIMUM 5YME30L • IMPORTANCE FACTOR OF 1-0, BUILDING CATEGORY 11 • INTERAL PRESSURE COEFFICIENT IS 0.18 3. WATER/CEMENT RATIO OF 058. CONCRETE MIX DESIGN SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AGI 301 CHAPTER 3, METHOD I OR METHOD 2. A, BI, 2, 3, ETCININ THE OONE THER CTION± • MINIMUM DESIGN PRESSURE FOR OPENINGS AND CLADDING 15 +25.9, -28.1 P5F RATED WAIL 5EE SUBMIT BACKUP DATA AS REQUIRED BY CHAPTER 5 SECTION 53 OF THE LATEST EDITION OF ACI 318 • NET UPLIFT DESIGN PRESSURE SHALL BE 30 P5F. 4. 5. ALL REINFORCING STEEL SHALL BE NEW DOMESTIC DEFOWED BILLET STEEL CONFORMING TO ASTM A415 GRADE 60. ALL CONCRETE WORK SHALL BE IN ACCORDANCE WITH 'THE BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE' ACI 318 INDICATE5 4 HOUR • DESIGN ROOF LIVE LOAD 15 20 PSF • ALL CONNECTIONS HAVE BEEN CHECKED TO WITHSTAND ALL APPLICABLE LOAD5. OTITLE LATEST EDITION, AND 'SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS,' AGI 301. 8. CONTRACTOR 15 SOLELY RESPONSIBLE FOR THE SAFETY OF THE BUILDING DURING CONSTRUCTION. 6. WHERE BAR LENGTHS ARE GIVEN ON THE DRAWINGS, THE LENGTH OF ANY HOOK, IF REQUIRED, 15 NOT INCLUDED. HOOKS SHALL BE 9. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR HAVING VISITED THE 51TE AND HAVING FAMILIARIZED HIMSELF WITH ALL PROVIDED AT DISCONTINUOUS ENDS OF ALL TOP BARS OF BEAMS AND AT 5LA55 EDGES, EX15TING CONDITIONS. ANY QUESTIONS OR DISCREPANCIES FOUND WITH REGARD TO THE DRAWINGS SHALL BE BROUGHT TO THE 1. CONTRACTOR SHALL PROVIDE SPACERS, CHAIRS, BOLSTERS, ETC. NECESSARY TO SUPPORT REINFORGING STEEL. SUPPORT ITEMS ATTENTION OF THE ARCHITECT BEFORE SUBMITTING A PROPOSAL. WHICH BEAR ON EXPOSED CONCRETE SURFACES SHALL HAVE ENDS WHICH ARE PLA571C TIPPED OR 5TAINLE55 STEEL. 10. 17 IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND SEQUENCE TO INSURE THE SAFETY OF 8. CONTRACTOR 5HALL PROVIDE 3/4 INCH CHAMFER ON ALL EXPOSED CORNERS OF COLUMNS, BEAM5, AND WALLS UNLE55 REFERENCE THE BUILDING AND ITS COMPONENT PARTS DURING ERECTION. THIS INCLUDES, BUT 15 NOT LIMITED TO, THE ADDITION OF WHATEVER PARTITION SECTION OTHERWISE INDICATED ON THE ARCHITECTURAL DRAWINGS. TEMPORARY BRACING, GUYS OR TIE -DOWNS MAY BE NECESSARY. SUCH MATERIAL SHALL BE REMOVED AND SHALL REMAIN THE 9, THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT: A INTERIOR PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF THE PROJECT. 3' CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH. MAX. HANGAR SPACE 11. IF MATERIALS, QUANTITIES, 5TRENGTH6 OR SIZES INDICATED BY THE DRAWINGS OR 5PECIFICATION6 ARE NOT IN AGREEMENT WITH GENERALNOTE 2' CONCRETE EXPOSED TO EARTH OR WEATHER "6 THROUGH r18 BARS NOTE THESE NOTES, THE BETTER QUALITY AND/OR GREATER QUANTITY, STRENGTH OR SIZE INDICATED, SPECIFIED OR NOTED SHALL BE 10. 11/2' ALL OTHER CASES MINIMUM LAP SPLICES ON ALL REINFORCING BAR SPLICES SHALL BE 48 BAR DIAMETERS TTP. EXCEPT WHERE OTHERWISE NOTED MAX. HGT. IN FEET 12. PROVIDED. PROJECT SHALL BE TURNED OVER TO OWNER IN CLEAN CONDITIONS WITH ALL TRASH AND DEBRIS REMOVED FROM SITE, ALL NO ON THE DRAWINGS. WINDOWS AND GLA55 CLEAN, ALL FLOORS CLEAN, ALL HORIZONTAL SURFACES DUSTED AND CLEANED, AND ALL TOILET AND IL WELDED WIRE FABRIC SHALL CONFORM TO ASTM A-185. WILF SHALL BE LAPPED AT LEAST 8' AND CONTAIN AT LEAST ONE CRO55 PLUMBING FIXTURES CLEAN AND IN GOOD WORKING ORDER 13. CONTRACTOR SHALL HAUL ALL RUBBISH FROM 51TE ON'A REGULAR BASIS, AND SHALL NOT ALLOW DEBRIS TO ACCUMULATE. 12. WIRE WITHIN THIS V. CONTRACTOR SHALL VERIFY LOCATIONS OF ALL OPENINGS, SLEEVES, ANCHOR BOLTS, INSERTS, ETC, AS REQUIRED BY OTHER 14. CONTRACTOR TO OBTAIN ALL PERMIT5, AND PAY ALL FEES AND TAXES. 15. DIMENSIONS INDICATED ON THE DRAWINGS IN REFERENCE TO EXISTING CONDITIONS ARE BASED ON THE BEST AVAILABLE DATA A$ 13, TRADES BEFORE CONCRETE 15 PLACED. HORIZONTAL WALL, BEAM AND FOOTING 5AR5 SHALL BE BENT 1'-0' AROUND CORNERS OR CORNER BARS WITH 2'-0' LAP SHALL PROVIDED BY THE OWNER BEFORE PROCEEDING WITH ANY WORK, THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS, GRADES, LINES, LEVELS OR OTHER CONDITIONS OF LIMITATIONS A7 THE SITE TO AVOID CONSTRUCTION ERRORS. IF ANY WORK IS 14. BE PROVIDED. c 7 CONCRETE f ALL REINFORCING DETAILS SHALL CONFORM TO 'MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED PERFORMED BY THE CONTRACTOR OR ANY SUBCONTRACTORS PRIOR TO ADEQUATE VERIFICATION OF APPLICABLE DATA, ANY RESULTANT EXTRA CAST FOR ADJUSTMENT OF WORK SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR 15. STRUCTURES' AGI 315 LATEST EDITION, UNLESS DETAILED OTHERW15E ON THESE PLANS. CONTRACTOR SHALL REVIEW ARCHITECTURAL AND MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF EMBEDDED ITEMS, SCALING DIMENSIONS FROM PLANS 15 PROHIBITED. ROOF SLEEVES, SLAB DEPRESSIONS, SLOPES, ETC. REQUIRED BY OTHER TRADES. THESE ITEMS HALL BE FUW16HED AND INSTALLED 16. A DE51GNATED LOCATION FOR STORAGE OF CONSTRUCTION MATERIAL AND EQUIPEMNT SHALL BE DETERMINED BY THE OWNER CONTRACTOR IS RESPONSIBLE FOR SCHEDULING DELIVERY, RECEIVING, UNLOADING, STORING, PLACING AND PROTECTING FROM I6. PRIOR TO PLACEMENT OF CONCRETE. FOR BEAMS, LAP BOTTOM STEEL AT THE SUPPORT AND TOP STEEL OVER THE MIDSPAN, UNLE55 NOTED OTHERWISE. DAMAGE ALL NEW EQUIPMENT AND MATERIALS FURNISHED BY THE CONTRACTOR, OR BY THE OWNER FOR THE CONTRACTORS USE. 11. TESTING LABORATORY SHALL SUBMIT ONE COPY OF ALL CONCRETE TEST REPORTS DIRECTLY TO THE ARCHITECT. 11. CONTRACTOR SHALL PROVIDE, AND 5U5MIT WITH PERMIT APPLICATION, ALL PRODUCT CERTIFICATIONS AND MANUFACTURER'S O 5YME30L INSTALLATION SPECIFICATIONS FOR SELECTED MATERIALS REQUIRED FOR EXTERIOR CLADDINGS, ROOFING, AND STRUCTURAL CONSTRUCTION COMPONENTS, SHOWING COMPLIANCE WITH STATE OF FLORIDA PRODUCT APPROVAL COMPLIANCE. PROJECT INDICATE5 I HOUR A, BI, 2, 3, ETCININ THE OONE THER CTION± O RATED WAIL 5EE LOCATIONS OFF MAIN GRID NOTED UL430 ON A2, A2,41, ETC. INDICATE5 4 HOUR ® RATED WAIL 5EE UL -U901 ON A2, CODES CTED / UN5PRINKLED GROUP III, TYPE 2 OOP 16,000 5F PER FLOOR(2)11,900 5F 5LDG5 5EPARADED DY 4 HR WALL 2 1 12,000 5F (2)11,900 5F 5LDG5 5EPARADED 5Y 4 HR WALL 55' 24'=3' (ROOF PEAK) FIRE PROTECTION REQUIREMENTS (TABLE 600) STRUCTURAL FRAME 0 HOURS EXTERIOR BEARING (301) 0 HOURS PER TABLE 601 NOTE F EXTERIOR NON-5EARING630') O HOURS INTERIOR SEARING WALLS 0 HOURS INTERIOR NON-BEARING WAL15 FIRE WALL 4 HOUR5 FLOOR O HOURS ROOF 0 HOURS FOLLOWED BY LETTERS OCCUPANCY ANALY515 INTENDED FOR THE STORAGE OF AIRCRAFT. 2 A3 OPP. SYMBOLS KEY ROOMTITLE ROOM FIRST DIGIT REPRESENTS FLOOR 101 TARGET LEVELROOM NUMBER . REMAINING DIGITS 01 THRU'39 0.18 MEAN ROOF HEIGHT (FT) DOORS LABELED BY NUMBER OF IOTA DOOR SPACE INTO WHICH DOOR SWINGS, IN 315 5YMF301_ FOLLOWED BY LETTERS 4/12/m(o ALPHABETICAL SEQUENCE. SCALE WINDOW CD O 5YME30L NUMBERED BY TYPES. PROJECT GRID LINE A, BI, 2, 3, ETCININ THE OONE THER CTION± O TARGET LOCATIONS OFF MAIN GRID NOTED A2,41, ETC. -DRW�G.TITLE OTITLE g�NO. WING•0' SCALE MAJOR BLDG. SECTION DETAIL NO. AI DICATE5 DIRECTION OF DETAIL CUT AND/OR LOCATION. SHEET ON WHICH DETAIL IS DRAWN. PARTIAL SECTION L_ DETAIL AI REFERENCE ID PARTITION SECTION AI ARTITION TYPE A INTERIOR ELEVATION +\-DIRECTION O VIEW. of GENERALNOTE NUMBER NOTE 01 LOCATION OF NOTE APPLICATION. MATERIALNOTE NUMBER NO 04200.A LOCATION OF NOTE APPLICATION. WIND VELOCITY (MPH) 120 IMPORTANCE FACTOR 1.00 EXPOSURE CATEGORY B INTERNAL PRESSURE COEFFICIENT +/- 0.18 MEAN ROOF HEIGHT (FT) 23 BUILDING WIDTH (FT) 16 BUILDING LENGHT (FT) 315 ROOF SLOPE (X:12) .5 COMPANY ERIC KURITZKY, ARCHITECT PREPARED BY ERIC KURITZKY, ARCHITECT CLIENT NAME TRACY FORREST JOB D15CRIPTION SANFORD HANGARS LARGE BOX W/CMU WALL JOB NUMBER 25053.4 ----------------------- OPENING OPENING LOCATION OPENING OPENING DIMENSIONS MAXIMUM P051TIVE MAXIMUM NEGATIVE MARK DESCRIPTION ZONE ELEVATION WIDTH (Ft) HEIGHT (ft) PRESSURE (W) PRESSURE ( 5l') 101 OVERHEAD 5 1 50 14 11.0 -182 102 OVERHEAD 5 1 40 14 11.6 =19.4 103 HOLLOW METAL 5 3.33 3 6.66 22.6 -29.5 Mill 11 WIDTH -OF -E y GE- IF T= 99,11 San Fire P ev Di Date: lO h O ® O a lO OI a a . JtjL 0 T v m� L 0 a H W r a } Y 0 n w 0 ID ID N c 0 n c E. v m N N a X m ml t } 0 O L_ 3 c m n 0 -v m N m L_ 0 0 0 E L 0 N C I-0 c v I Y N SOUTHEAST RAMP - PHASE 2A SEE 51TE PLAN BY OTHERS FOR SIDEWALKS, DRIVEWAYS d PAVING. FE -FIRE EXTINGUISHERS�2 P L #' LARGE BOX HANGAR - N HANGARS PROVIDE PURPLE K10 A3 PLANS REVIEWED SCALE: 3132" = V-0" CITY OF SANFORD n W CZD o CJD t CHECKED m EDK DATE o 4/12/m(o •v m SCALE CD A5 NOTED PROJECT N0. 25(d53.4 c L_ O 0 4 m O m U O � -Gid P L 0 0 '1- 0 C75 ` v I-0 c v I Y N SOUTHEAST RAMP - PHASE 2A SEE 51TE PLAN BY OTHERS FOR SIDEWALKS, DRIVEWAYS d PAVING. FE -FIRE EXTINGUISHERS�2 P L #' LARGE BOX HANGAR - N HANGARS PROVIDE PURPLE K10 A3 PLANS REVIEWED SCALE: 3132" = V-0" CITY OF SANFORD n W U LARGE BOX HANGAf,; a GENERAL NOTES Y &12� ITR P�, ml � N Fx SHEET 0 a vW Al DRAWN o CJD t CHECKED m EDK DATE 0 4/12/m(o •v m SCALE CD A5 NOTED PROJECT N0. 25(d53.4 U LARGE BOX HANGAf,; a GENERAL NOTES Y &12� ITR P�, ml � N Fx SHEET 0 a vW Al UL 430 1 HR RATED WALL ASSEMBLY Design: No:643D October 07;'2004 Nonbearing Wail Rating - 1 or 2 Hr. 2. Ha Cor f gi.1.i•0-1011 1. Floor and Ceiling Runners- (Not shown) -Channel shaped, fabricated from min 20 MSG (0.038 in. thick) corrosion -protected or galv steel, rain width to accommodate stud size, with rain 1 in. long legs, attached to floor and ceiling with fasteners spaced max 24 in. OC. 2. Steel studs - Channel shaped, fabricated from niih:20 MSG (0.0327 in. thick) corrosion -protected or gaiv steel, 3-1/2 in. min width, min t-1/2 in.' flanges and, 1/4. in: return, spaced a max of 16 In. OC. Studs friction -fit into floor and ceiling runners. Studs to be cut 5/8 to 314 In.less than assembly height, 3. Lead Batten Strips -- Lead batten strips, 2 in. wide, max 10 It long with a max thickness of 0.080 in. Strips placed on the interior face of studs and attached from the exterior face of the stud with two 1 in. long Type S- 12 pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead batten strips to. have a purity of 99.9*,Io meeting the Federal specification QQ-L-201f, Grade "C" . Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item S) and optional at remaining stud locations. 4. Batts and Blankets* - (Optional) -Placed iii -stud (avides, any glass fiber or mineral wool insulation bearing the UL Classification Marking as to Surface 36ming; Characteristics arid/or Fire Resistance, See Batts and Blankets (BKNV or BZIZ) Categories for names of Classified companies. 5. Gypsum Board- Nom 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. long Type S-12 steel. screws spaced 6 in. OC at perimeter and 12 In. OC in the field. - RAY -BAR ENGINEERING CORP - Type RB-LBG� 6. Gypsum Board* - Nem 5/8 in. thick gypsum panels with beveled, square or staggered edges 1 Hr. Configuration When substitutedforlead backed gypsum panels (Itern 5), panels applied vertically with joints staggered rain 1 stud cavity from lead backed gypsum panels (Item 5) on opposite sides of studs. Wallboard secured to studs with 1 in. long Type S-12 steel screws spaced 8 In. OC at perimeter and 12 in. OC In the field. 2 Hr. Configuration When substituted for lead backed gypsurn panels (Item 5), base layer panels applied vertically with joints staggered min 1 stud cavity from lead backed gypsum panels (Item 5) on opposite sides Of studs. Wallboard secured to studs with I In. long Type S-12 steel screws spaced 24 in. OC at the perimeter arid in the field. Face layer applied vertically or horizontally. When applied vertically, joints In adjacent layers staggered min 1. stud cavity. When applied horizontally, butt joints centered over studs and staggered a min 1 stud cavity from vertical joints in adjacent layer. When applied vertically over lead backed gypsum panels (Itefu 5), panels secured to studs with 1-5/8 in. lung Type S-12 steel screws spaced t2 In. OC and staggered from screws on base layer. When applied horizontally. ever lead backed gypsurn panels (Item 5), panels secured to studs with 1-5/8 in. long Type S-12 steel screws: spaced 8 in. OC at the perimeter and in the Fleid, screws staggered from screws ori base layer.. When applied vertically over gypsum panels (Item 6), panels secured to studs with 1-S/8 in. long Type 5-12 steel screws spaced 12 in. OC and staggered 12 in. from screws on base layer. When applied horizontally over gypsum panels (Item 6), panels secured to studs with 1-5/8 in. long Type S-12 steel screws spaced 8 in. OC at the perimeter and in the field, screws staggered 8 In. from screws on base layer. CANADIAN GYPSUM COMPANY -Type AR, C, IP -X 1, IP -X2, SCX, SHX UNITED STATES GYPSUM CO -- Type AR, C, FRX-G, IP -X1, IP -X2, SCX, SHX USG MEXICO s A DE C V - Type AR, C, IP -X1., IP -X2, SCX; SHX 7: joint Tape and Compound - (Not shown) -Vinyl or casein, dry or premixed joint Compound applied in two cats to joints ond screw heads of outer layer. Paper tape, nom 2 in wide, embedded in first layer of cornpound over all j0int3 of outer panels. UL -U901 4 HR RATED WALL ASSEMBLY Design No. U901 October 26, 1993 Bearing Wall Rating -4 HR. Nonbearing Wall Rating - 4 HR. f: 1p �• ,41.1 •� �A. 3 .• �;�f. I a 4 III 1 ry 1 d•I, ..-..-. 4 a,j :A ,ter. L,'.;•4 1. Concrete Blocks* - Various designs. Classif cation B-4 (4 hr). See Concrete Blocks category for lists of eligible manufacturers. 2. Mortar - Blocks laid in full bed of mortar, nom. 3/8 in. thick, of not less than 2-1/4 and not more than 3- 1/2 parts of clean sharp sand to 1 part Portland cement (proportioned by volume) and not more than SO percent hydrated lime (by cement volume). Vertical joints staggered. 3. Portland Cement Stucco or Gypsum Plaster - If used, add 1/2 hr. to Classification. 4. Loose Masonry Fill - If all core spaces are filled with loose dry expanded slag, burned clay or shale (rotary kiln process), water repellant vermiculite masonry fill insulation, or silicone treated perlite loose fill insulation, Class D-2 (2 hr) or C-3 (3 hr) concrete blocks will provide a 4 hr fire resistance rating. 2 COUR5E5 CONCRETE FILLED LINTEL BLOCK W/ (2) #5 EACH COUR5E I (5EE SECTION EOR I HT.) I COUR5E CONCRETE ------- - I FILLED LINTEL I I COURSE ill/ (2) #5 (5EE SECTION FOR 12" MA50NRY WALL W/ HT.) (2) 15 IN CONCRETE FILLED" CELL5 Q 4'-0 O.C. (5) #5 BOT F5 INTERIOR FOOTING SCALE: 1/2" =1'-0" 5TEEL COLUMN BY OTHER5 (TYP) 5/5"=11, A913, GRD 5I THRID ROD (4140) SET IN 51MP50N 5ET HIGH 5TR'TH EPXY MIN. 5" DEPTH a a la. 1 d.J , () #5 EA. WAY a� . BOTTOM 6" 3'-0" 6" F4 COLUMN FOOTING SCALE: 1/2" =1'-0" 54'-6" 315'-0" (4) #5 CONT. TOP 4 BOTTOM W/ #3 TIE5 636" O.C. d a ° da � �I I r d °�.-d �. w 611 11-411 F3 TYP. EDGE GRADE BM SCALE: 112" =1'-0" 5TEEL COLUMN BY OTHERS (TYP) 5/0"o 3/4"o A.B. 12" MIN. PLACEMENT DEPTH PER MFGR. °d a d1 ° a. e d d ° I. CO cd . (6) #6 EA. WAY TOP A 74V 4. BOTTOM 9" O.C. (F-1) 6" I Fl - 3'-0"X 3'-0" F2 TYP. ENDWALL COL. FOOTING SCALE: 1/2" = 1'-0" 45i-'�II nl �" IIIIY1t- I-rh,lllnllG MAT' /1C 5TEEL COLUMN BY OTHER5 (TYP) Vail 0 3/4"0 A.B. 15" MIN. PLACEMENT DEPTH PER MFGR. #5 HAIRPIN = =�� •% i.;. d GV d (6) 06 EA. WAY TOP r BOTTOM 9" O.C. (F-1) °—a - •d �4 .• �' m �� d e a 6 T C ~~ a � 611 F1 - 4'-6"X 4'-6" w O F1 TYP. COLUMN FOOTING o m SCALE: 1/2" =1'-0" 55'-011 55'-0" 48' 0" 54' 6" 54'-6" 45ll-Or SOUTHEAST RAMP - PHASE 2A - FOUNDATION PLAN SCALE: 3/3211=1'-0'1 O v � DRAWN o rz _' I� rn SDK m L -�C DATE O O SCALE A5 NOT1=D N PROJECT NO. 25053.4 v O LARGE BOX HANGAR F1/ FOUNDATION Y PLAN � N T n SHEET W c _ m O o 0 a 0 1d� S O 55'-0" 48' 0" 54' 6" 54'-6" 45ll-Or SOUTHEAST RAMP - PHASE 2A - FOUNDATION PLAN SCALE: 3/3211=1'-0'1 t t I n DRAWN m I� CHECKED SDK 0 DATE Q SCALE A5 NOT1=D N PROJECT NO. 25053.4 v LARGE BOX HANGAR 3 FOUNDATION Y PLAN � N T n SHEET W c O 0 1d� S O cv r m L m O t C O t t I DRAWN CJD I� CHECKED SDK DATE n SCALE A5 NOT1=D PROJECT NO. 25053.4 v LARGE BOX HANGAR E FOUNDATION PLAN � N T SHEET A2 c o 0 y m U a DRAWN CJD I� CHECKED SDK DATE n SCALE A5 NOT1=D PROJECT NO. 25053.4 LARGE BOX HANGAR FOUNDATION PLAN � T SHEET A2 c o 0 y m U a DRAWN CJD CHECKED SDK DATE 4/12/Oro SCALE A5 NOT1=D PROJECT NO. 25053.4 LARGE BOX HANGAR FOUNDATION PLAN SHEET A2 3 U v m r 0 L CL h 0 U m L U L Q T N N 3 Y U W w O C C ID h C O U C m .L 3 m U) V) m L M x m m t t 0 t h C C m E 0 U O 'O m h m s 0 O C O U 'O O E L 0 h c� 0 N m L h C O t U 7 O L a m L c Q h O� C .3 O L m h m L C O 'O m O C } U m �O L CL U 0 m a h m t L O v- C O .D m 7 h h m L U vl C O U m t U Q Y N t 7 Y n W O m O m L m O t C m C O U DIVISION 16 - ELECTRICAL SPECIFICATIONS GENERAL REQUIREMENTS LIGHT FIXTURES THE GENERAL CONDITIONS AND THE SUPPLEMENTARY CONDITIONS OF THE ARCHITECT SHALL BE CONSIDERED AS PART OF THIS SPECIFICATION. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BIDDING. BIDS SHALL SERVE AS EVIDENCE OF KNOWLEDGE OF ALL EXISTING SITE CONDITIONS. FIELD VERIFY THE EXISTING ELECTRICAL AND TELEPHONE SITE CONDITIONS AND ROUGH—IN (IF ANY). CONTRACTOR TO VERIFY THE INTERCONNECTION REQUIREMENTS OF EACH ELECTRICAL SYSTEM BETWEEN THIS SPACE AND ANY OTHER ATTACHED SPACE. THESE REQUIREMENTS ARE TO BE INCLUDED IN BID. FURNISH ALL LABOR, MATERIALS, EQUIPMENT, AND TOOLS TO PERFORM THE ELECTRICAL WORK AS INDICATED FOR A COMPLETE AND OPERABLE INSTALLATION. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY SERVICE, WIRING, POWER, AND LIGHTS AS REQUIRED. TEMPORARY SERVICE SHALL MEET ALL NEC AND OSHA REQUIREMENTS CONCERNING GROUND FAULT PROTECTION. UPON COMPLETION OF PROJECT, CONTRACTOR SHALL REMOVE ALL CONDUIT, CONDUCTORS, DEVICES, ETC., ASSOCIATED WITH TEMPORARY SERVICE AND WIRING. ELECTRICAL CONTRACTOR SHALL RECORD ALL FIELD CHANGES IN HIS WORK AS THE JOB PROGRESSES, AND UPON COMPLETION SHALL TURN OVER TO THE GENERAL CONTRACTOR A RECORD SET OF PRINTS SHOWING THESE CHANGES. COMPLYING AND PERMITS COMPLY WITH LOCAL CODES, STATE CODES, AND NATIONAL ELECTRICAL CODE (NEC), AND ALL APPLICABLE REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION AT THE SITE. WHERE THE REQUIREMENTS OF ANY OF THE AUTHORITIES LISTED ABOVE DIFFER FROM THE PLANS OR SPECIFICATIONS, THE MOST STRINGENT REQUIREMENTS TAKE PRECEDENCE OBTAIN PERMITS FROM THE AUTHORITIES HAVING JURISDICTION AND TURN OVER TO THE GENERAL CONTRACTOR. ALL MATERIALS USED IN THIS PROJECT SHALL BE NEW UNLESS OTHERWISE NOTED AND SHALL BE LISTED BY THE UNDERWRITIR'S LABORATORIES, INC., AS CONFORMING TO ITS STANDARDS WHERE SUCH STANDARDS HAVE BEEN ESTABLISHED. THESE MATERIALS SHALL BEAR THE LISTING MARK OF THE UL SUBMIT MATERIALS UST AND SHOP DRAWINGS FOR ALL MAJOR EQUIPMENT PROPOSED FOR THIS WORK TO THE GENERAL CONTRACTOR FOR REVIEW. SUBMITTALS SHALL BE IN ACCORDANCE WITH THE GENERAL CONDITIONS AND SHALL BEAR THE APPROVAL OF THE ELECTRICAL CONTRACTOR SHOWING THAT HE HAS REVIEWED THEM AND THAT THE PROPOSED MATERIALS ARE EQUIVALENT TO OR BETTER THAN THE SPECIFIED MATERIALS AS INDICATED ON THE DRAWINGS AND AS SPECIFIED HERON. CONTRACTOR SHALL PROVIDE AND INSTALL THE SPECIFIED MANUFACTURER AND MODEL NUMBER OF LIGHT FIXTURES AND LAMPS AS INDICATED ON THE LIGHTING FIXTURE SCHEDULE THE CONTRACTOR SHALL PROVIDE ADEQUATE INFORMATION ON ANY PROPOSED EXCEPTION TO THE SPECIFIED LIST NO LESS THAN THREE (3) DAYS PRIOR TO BID DATE PROVIDE MANUFACTURER AND MODEL NUMBER OF PROPOSED EXCEPTIONS AND, IF REQUESTED, PROVIDE CUT SHEET, PHOTOMETRICS, AND SAMPLES. FIXTURE SUBMITTALS NOT AS SPECIFIED AND PROVIDED AFTER BID WITHOUT PRIOR APPROVAL WILL NOT BE ACCEPTED FOR REVIEW. GROUNDING AND BONDING GROUND THE SYSTEM IN ACCORDANCE WITH ARTICLE 250 OF THE LATEST ADOPTED ISSUE OF THE N.E.C. ALL EQUIPMENT, MOTOR, FIXTURE, RECEPTACLE, OR DEVICE TO WHICH CURRENT CARRYING CONDUCTORS ARE CONNECTED SHALL. HAVE A SEPARATE GREEN EQUIPMENT GROUNDING CONDUCTOR, SIZED IN ACCORDANCE WITH N.E.C. TABLE 250-95, AND TO BE INSTALLED IN THE RACEWAY AND CONNECTED TO THE DEVICE ALL GROUNDING OR BONDING CONDUCTORS SHALL BE SIZED AS REQUIRED BY THE NEC AND SHALL BE THWN/THHN INSULATED WITH GREEN COLOR CODING. ALL ELECTRICAL EQUIPMENT ENCLOSURES AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED. SAFETY SWITCHES SAFETY SWITCHES SHALL BE GENERAL DUTY SAFETY SWITCHES WITH 100,000A SHORT CIRCUIT RATING AND SHALL BE LISTED IN ACCORDANCE WITH U.L 98. THE COVER SHALL BE INTERLOCKED SO THAT THE DOOR CANNOT BE OPENED WITH THE HANDLE IN THE 'ON' POSITION, EXCEPT BY THE INTENTIONAL OPERATION OF A CONCEALED RELEASE (DEFEATER) MECHANISM. PROVIDE NEMA 1 ENCLOSURES FOR INTERIOR LOCATIONS AND NEMA 3R ENCLOSURES FOR EXTERIOR LOCATIONS. SAFETY SWITCHES AND DISCONNECTS SHALL BE FUSED (FOR A/C EQUIPMENT AS PER U.L LISTING AND LOCAL CODE REQUIREMENTS) OR NON—FUSED AS INDICATED ON DRAWINGS OR AS REQUIRED BY THE NEC. SWITCHES SHALL BE MANUFACTURED BY GENERAL ELECTRIC, SQUARED, SIEMENS, WESTINGHOUSE, OR EQUIVALENT. PROVIDE ENGRAVED PHENOLIC NAMEPLATES FOR ALL SAFETY SWITCHES INDICATING EQUIPMENT SERVED. FUSES TO BE BUSSMAN TYPE, DUAL—ELEMENT, TIME DELAY, TYPE RKS. LIGHT FIXTURE SCHEDULE SHOWS REQUIRED TYPE OF FIXTURES ONLY. DETERMINE MODIFlCATTONS REQUIRED TO MAKE FIXTURES SUITABLE FOR COUNGS AS INSTALLED., AND FURNISH FIXTURES ADAPTED TO THE CEILING USED. FIXTURES SHALL BE U.L APPROVED. THIS CONTRACTOR SHALL PROTECT THE FIXTURES AND LAMPS, AND SHALL REPLACE BROKEN PARTS. ALL LENSES AND LOUVERS IN ANY AREAS SHALL BE CLEANED AFTER ALL TRADES HAVE COMPLETED THEIR WORK IN THAT AREA. ALL RACEWAY ROUTED CONCEALED ABOVE CEILING OR IN WALL SHALL BE EMT. ALL CONDUIT EXPOSED TO THE PHYSICAL DAMAGE OR OUTSIDE SHALL BE GALVANIZED RIGID STEEL OR INTERMEDIATE METAL CONDUIT. MINIMUM SIZE OF RACEWAY SHAH. BE 1/2'. UNDERSLAB OR UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC CONDUIT. SIZE CONDUIT PER N.E.C. FOR ENCLOSED WIRING. FITTINGS SHALL BE APPROVED AND U.L LISTED FOR THE RACEWAY INSTALLED. PROVIDE PULLSTRINGS IN ALL EM1PY CONDUITS. ALL CONDUIT TERMINATING IN OUTLETS, JUNCTION OR PULL BOXES, AND CABINETS MUST TERMINATE WITH A LOCKNUT AND BUSHING, EXCEPT AT EXPOSED CAST BOXES WHERE THEY MAY BE OMITTED. RIGID CONDUIT SHALL BE INSTALLED WITH DOUBLE LOCKNUTS AND BUSHING. COUPLINGS, CONNECTORS, AND FITTINGS FOR EMT SHALL BE STEEL SETSCREW. FLEXIBLE METAL CONDUIT SHALL BE USED FOR CONNECTIONS TO LIGHTING FIXTURES, FIXED APPLIANCES AND MOTORS WHERE FLEXIBILITY IS REQUIRED, FIXTURE WHIPS MAY BE 1/2' TO 3/8' TO INDIVIDUAL FIXTURES AND ALL OTHER SHALL BE 1/2'. PVC CONDUIT SHALL BE INSTALLED WITH FACTORY ELBOWS AND FITTINGS. USE ONLY APPROVED SOLVENT GLUE FOR THE CONDUIT AND FITTINGS. FIELD BENDING OF PVC CONDUIT MAY BE PERFORMED ONLY WITH THE CONDUIT MANUFACTURER'S NOT BOX' APPROVED BENDERS. ALL CONDUCTORS MUST BE IN A RACEWAY. NO BX OR ROMEX ALLOWED. MX TYPE IS ALLOWED WHEN ITS' USE IS PERMITTED BY THE AUTHORITIES HAVING JURISDICTION. CONDUCTORS ALL CONDUCTORS SHALL BE #12 COPPER (MINIMUM) WITH THHN/M INSULATION AND SHALL CONFORM TO THE CURRENT ISSUE OF THE N.E.C. ARTICLES 300 AND 310, AND SHALL MEET ASTM SPECIFICATIONS. ALL CONDUCTORS SHALL BE NEW FREE OF KINKS AND OTHER DEFECTS WHEN INSTALLED. MINIMUM WIRE SIZE SHALL BE NO. 12 (EXCEPT NO. 14 FOR CONTROL WIRING) AND SHALL BE SOFT DRAWN COPPER, SOLID WITH THWN/THHN INSULATION IN SIZES THROUGH NO. 10 AND STRANDED WITH THWN/THHN INSULATION FOR NO. 8 AND LARGER. INSULATION SHALL BE SUITABLE FOR 600 VOLTS AND MUST BEAR THE CONDUCTOR SIZE, TYPE OF INSULATION, AND THE MANUFACTURER'S NAME STAMPED AT REGULAR INTERVALS. COLOR CODING SHALL BE AS FOLLOWS: SYSTEM VOLTAGE: 240/120 VOLT PHASE A BLACK PHASE B RED PHASE C BLUE NEUTRAL WHITE GROUND GREEN COLOR CODE SHALL IDENTIFY THE SAME PHASE THROUGHOUT THE SYSTEM FROM MAIN SWITCH THROUGH ALL BRANCH CIRCUITRY. PROVIDE ALL SUPPORTS FOR MATERIAL. AND EQUIPMENT. PROVIDE STRAIN RELIEFS FOR OVERHEAD DROP SERVICE CORDS. WIRING A COMPLETE SYSTEM OF CONDUCTORS SHALL BE INSTALLED FOR ALL FEEDERS, BRANCH CIRCUITS, AND CONTROL CIRCUITS AS NOTED ON THE PLANS. NO WIRE IS TO BE INSTALLED IN RACEWAY UNTIL THE ENTIRE RACEWAY SYSTEM IS COMPLETE AND THEN ONLY WITH THE USE OF AN APPROVED WIRING LUBRICANT. BRANCH CIRCUIT SIZES ARE NOTED ON THE PLANS AND MUST BE CONTINUOUS WITHOUT REDUCTION IN SIZE THROUGHOUT THEIR LENGTH BETWEEN FIXTURE, EXCEPT WHERE CONNECTING TO FIXTURES. BRANCH CIRCUITS EXCEEDING 70 FEET IN TOTAL LENGTH SHALL BE A MINIMUM OF NO. 10 AWG TO THE FIRST OUTLET OR FIXTURE (PHIS DOES NOT APPLY TO CIRCUITS WITH LARGER THAN NO. 12 CONDUCTORS ALREADY INDICATED ON PLANS). TELEPHONE PREWIRING PROVIDE ALL NECESSARY WIRING, BOXES AND RELATED ACCESSORIES REQUIRED BY LOCAL TELEPHONE COMPANY FOR COMPLETE PREWIRED UNIT INSTALLATON OF TELEPHONE SERVICE TO TELEPHONE COMPANY INTERFACE. WIRING DEVICES THE FOLLOWING LISTED HUBBELL DEVICES MAY BE THE PRODUCT OF EAGLE, P do S, OR ARROW—HART, BUT MUST BE EQUIVALENT TO THE DEVICES LISTED AND MUST BE IDENTIFIED IN THE SUBMITTALS. ALL DEVICES SHALL BE GANG MOUNTED WHERE POSSIBLE. SWITCHES: SINGLE POLE, 20 AMPERES, 120/277 VOLT. CS120—W RECEPTACLES: DUPLEX, NEMA 5-20R, 20 AMP, 125 VOLT: CR20—W THE COLOR OF ALL WIRING DEVICES SHALL BE IVORY (FIELD VERIFY TO MATCH EXISTING COLOR) UNLESS OTHERWISE NOTED OR AS APPROVED/DIRECTED BY THE ARCHITECT. COVER PLATES SHALL BE PLASTIC, COLOR TO MATCH THE ASSOCIATED DEVICE. EQUIPMENT CONNECTIONS THE ELECTRICAL. CONTRACTOR SWILL. MAKE ALL POWER CONNECTIONS TO EQUIPMENT INCLUDING ALL THE ONES INSTALLED BY THE HVAC AND PLUMBING CONTRACTORS. ALL CONTROL WIRING NOT INDICATED ON THE PLANS WILL BE THE RESPONSIBILITY OF OTHER TRADES. THE ELECTRICAL CONTRACTOR MUST OBTAIN ROUGH—IN INFORMATION FROM OTHER CONTRACTORS AND VERIFY THE ACTUAL PURCHASED EQUIPMENT PRIOR TO INSTALLATION. VERIFY THE THERMAL CONDITIONS OF THE EQUIPMENT BASED ON NAMEPLATE DATA AND CONNECT AS THE LISTING REQUIREMENTS ARE STATED USING THE SPECIFIED MATERIALS. ALL POWER AND CONTROL CIRCUITS FOR ELECTRICAL EQUIPMENT REQUIRING ELECTRICAL. CONNECTIONS ARE BASED ON THE DESIGN AS INDICATED WITHIN THE CONTRACT DOCUMENTS. THE DIVISION 16 TRADESMAN SHALL VERIFY ALL PURCHASED EQUIPMENT THAT REQUIRES ELECTRICAL CONNECTION WITH THE RESPONSIBLE CONTRACTOR OR VENDOR PRIOR TO ELECTRICAL ROUGH—IN. ANY DEVIATIONS IN EQUIPMENT ROUGH—IN REQUIREMENTS FROM THE CONTRACT DOCUMENTS SHALL BE CONSIDERED A COORDINATION ITEM THAT THE ELECTRICAL TRADESMAN SHALL DISCUSS WITH THE OTHER TRADES INVOLVED. APPARATUS IDENTIFICATION PANELBOARDS, CIRCUIT BREAKERS, DISCONNECT SWITCHES AND OTHER APPARATUS USED FOR THE OPERATION AND CONTROL OF CIRCUITS, APPLIANCES AND EQUIPMENT SHALL BE PROPERLY IDENTIFIED BY MEANS OF ENGRAVED LAMINATED PLASTIC DESCRIPTIVE NAMEPLATES MOUNTED ON THE APPARATUS USING PERMANENT CONTACT CEMENT. PROVIDE TO THE OWNER UPDATED PANELBOARD DIRECTORIES UPON COMPLETION OF CONSTRUCTION. GUARANTEE MATERIALS, EQUIPMENT, AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF ACCEPTANCE DEVICE MOUNTING HEIGHTS ALL MOUNTING HEIGHTS ARE TO THE CENTER OF DEVICE, UNLESS SHOWN OR NOTED OTHERWISE: SWITCH: 48' A.F.F. RECEPTACLE: 18' A.F.F. OR AS NOTED TELEPHONE: ON CENTERLINE OF ADJACENT DEVICES (RECEPTACLES). DISCONNECT SWITCH: NOT LESS THAN 24' A.F.F. OR A.F.G. AND NOT MORE THAN 6'-5' A.F.F. OR A.F.G. TO TOP OF HANDLE, UNLESS SHOWN OR NOTED OTHERWISE ELECTRICAL ABBREVIATIONS; ELECTRICAL SYMBOL LEGEND A AMPERE ® EXIT FIXTURE — SINGLE OR DOUBLE FACE DIRECTIONAL ARROWS AS SHOWN ON PLANS AFF ABOVE FINISHED FLOOR O WALLPACK, SEE LIGHT FIXTURE SCHEDULE AFG 3 ABOVE FINISHED GRADE O HIGH BAY OR DOWNLIGHT LIGHT FIXTURE, SEE LIGHT FIXTURE SCHEDULE C CONDUIT Al)k COMBINATION BATTERY OPERATED EMERGENCY / EXIT LIGHT FIXTURE C.B. CIRCUIT BREAKER i $ SWITCH — SINGLE POLE, +48A.F.F. E EXISTING $� ROTARY TIME SWITCH, INTERMATIC jFD60MC—IVORY OR EQUAL EF EXHAUST FAN $3 THREE WAY SWITCH, +48' A.F.F. EWC ELECTRIC WATER COOLER $3T 3—WAY ROTARY TIME SWITCH, INTERMATIC #FD32H—IVORY OR EQUAL EWH ELECTRIC WATER HEATER 3 cxi cf) DUPLEX RECEPTACLE, NEMA 5-20R FF FINISHED FLOOR ' DUPLEX RECEPTACLE MOUNTED 48' A.F.F. GFI GROUND FAULT CIRCUIT INTERRUPTING ® 30A, 250V RECEPTACLE, 48' A.F.F. GND GROUND Q JUNCTION BOX KAIC KILO—AMPERES OF INTERRUPTING CURRENT PANELBOARD, 240/120V, SEE PANELBOARD SCHEDULE M.C.B. MAIN CIRCUIT BREAKER D NEMA 3R METER BASE AND SOCKET. METER BY POWER CO. S/N SOLID NEUTRAL i/--RPA-1,3,5 HOMERUN TO PANEL (ONE ARROW PER CIRCUIT) TTB TELEPHONE TERMINAL BOARD CONDUIT CONCEALED IN WAIS TYP. TYPICAL CONDUIT EXPOSED XFMR TRANSFORMER CONNECTION TO EQUIPMENT V VOLT FUSED DISCONNECT SWITCH, S/N, 2 — POLES, 60 — FRAME SIZE, 40 — FUSE SIZE WP WEATHERPROOF OR NEMA 3R 2240 0 GARAGE DOOR OPENER CONTROL PAD, +48' A.F.F. MM- ALL INDICATED MOUNTING HEIGHTS ARE TO THE BOTTOM OF DEVICE UNLESS OTHERWISE SHOWN OR NOTED. GENERAL ELECTRICAL NOTES 1. THE USE OF ANY PROCESS INVOLVING ASBESTOS OR PCB, AND THE INSTALLATION OF ANY PRODUCT, INSULATION, COMPOUND OF MATERIAL CONTAINING OR INCORPORATING ASBESTOS OR PCB, IS PROHIBITED. THE REQUIREMENTS OF THIS SPECIFICATION FOR A COMPLETE AND PROPERLY OPERATING ELECTRICAL SYSTEM SHALL BE MET WITHOUT THE USE OF ASBESTOS OR PCB. 2. AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES ENCOUNTERED WILL NOT BE RECOGNIZED. 3. ALL WORK TO BE PERFORMED IN ACCORDANCE WITH NEC 2005 AND ALL OTHER CODES AND REGULATIONS OF AUTHORITIES HAVING JURISDICTION. 4. IT IS THE INTENT THAT THE WORK INDICATED ON THESE DRAWINGS BE PERFORMED IN A WORKMANLIKE MANNER AND BE COMPLETE IN EVERY RESPECT FOR OCCUPANCY BY THE OWNER. TOLERANCES TYPICALLY 1/8' IN 10'-0' U.N.O. 5. INSTALL. ALL MATERIALS AND FIXTURES PER MANUFACTURER'S RECOMMENDATIONS. 6. FIELD VERIFY ALL DIMENSIONS AND ROUGH—IN DIMENSIONS WITH ACTUAL CONDITIONS. 7. ALL SYSTEMS AND CONSTRUCTION TO BE COMPLETE IN EVERY RESPECT AND OPERATIONAL FOR THE PURPOSE FOR WHICH THEY WERE INTENDED. PROVIDE OWNER WITH ALL WARRANTIES / MANUALS FOR MATERIALS, SYSTEMS, ETC. 8. PROVIDE ELECTRICAL SYSTEM COMPONENTS AND ITEMS AS REQUIRED. ELECTRICAL CONTRACTOR TO PROVIDE ADDITIONAL DRAWINGS FOR PERMIT AND ALL LABOR, MATERIALS, AND ANY MISCELLANEOUS ITEMS NECESSARY FOR A COMPLETED SYSTEM READY FOR OPERATION DISCLAIMER NOTICE: THIS DOCUMENT CONTAINS PRIVILEGED AND CONFIDENTIAL INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY 'AZ POWER SYSTEMS' FOR THE USE OF THE INTENDED RECIPIENT, AND FOR AN INTENDED PURPOSE ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN CONSENT OF 'AZ POWER SYSTEMS' IS STRICTLY PROHIBITED. ..................... Power Systems FL License 160953 11655 Swift Water Circle Orlando, FL 32817 Phone/Fox: 40724J6020 arpo wersystemsObellsouth. net C/D C_� ton O � � cxi cf) w LIGHT FIXTURE SCHEDULE LIGHT FIXTURE DATA LAMP DATA BALLAST DATA DESCRIPTION ID MANUFACTURER MODEL NUMBER TYPE WATTS QTY. TYPE VOLTS MAIN AMPS: ....................................................................................... A ........................ LTTHONIA ......................................................................................................_................................,.,._...,....,.......,.............._ UNS 2 32 120 ..... ._----.......i,..._.,.......... .... .. .:. FLUORESCENT ( 32 t 2 # ELECTRONIC 120 4' HEAVY-DUTY FLUORESCENT STRIP, 2 -LAMP, HIGH GLOSS BAKED ENAMEL CIRCUITS: 42 i r i SERVICE: FINISH H LITHONIA TWA 100A 120 SF LPI METAL HALIDE 100 1� HPF 120 DIE-CAST ALUMINUM WALLPACK, LAMP INCLUDED, FINISH SELECTION BY OWNER, KVA OM� MEDIUM BASE CKT. FUSED, INSTALL AT -9'-0* A.F.G. TO BOTTOM :.. .-.-.:::..: .: .......... r.:.,,..,...., -....,:....,,:.........:.. LOCATION OF PANELBOARD AND METERING. KVA K DAYBRIfE NITS BRTTES FU 400 M 120 ISF WRABH GG1 METAL HALIDE 1 400 1 i HPF 120 INTERMEDIATE FLOODLIGHT, DIE-CAST ALUMINUM, GASKETED, N0. IP .,,..:.:.....: POLE POLE LOAD SERVED t DARK BRONZE POLYESTER FINISH, INSTALL AT N14'-6' A.F.G. TO BOTTOM XEM ..::: MCPHILBEN - - - - CCAXL 1 G W H LED 8 2 -120 Ma .4 H, :::.:. COMBINATION EMERGENCY BATTERY FIXTURE AND SINGLE GREEN 2 20 MR16 HALOGEN ( LTG EXTERIOR FACE IXCt LIGHT, WHITE HOUSING, EMERGENCY NI -CAD BATTERY NOTES: 1. PROVIDE ENERGY SAVING LAMPS AND BALLASTS. 2. ALL EXIT AND BATTERY PACK LIGHT FIXTURES SHALL BE CONNECTED AHEAD OF ROOM LIGHT SWITCHING. 3. EQUAL MANUFACTURERS TO BE LTTHONIA, LIGHTOLIER AND COOPER. 3. VERIFY- AND COORDINATE EXACT FIXTURE MOUNTING HEIGHTS WITH THE OWNER PRIOR TO ROUGH IN. FEEDER / CONDUIT SCHEDULE ID MARK WIRE SIZE (AWS) GROUND SIZE (AWS) CONDUIT SIZE ® 2010 #10 5/4' BUS AMPS: 225 PHASE:. 1 K u. 1. LUG LOCATION: BOTTOM g k I i i i ` THEY PENETRATE E MAIN AMPS: 200 M.C.B. WIRE: 3 NOTED OR SPECIFIED OTHERWISE 3. MOUNTING: SURFACE CIRCUITS: 42 THIS BUILDING FOR CONTROL OF LIGHT FIXTURES TYPE 'K' AND W. INTERMATIC JK4321 C SERVICE: 240/120 V OPTIONS: NEMA 3R 5. TYPE: SQUARE D• NQOD AIC RATING: 10K ROUTED BELOW 18' A.F.F. TO BE IXPLOSIONPROOF TYPE KVA OM� CB CKT. BUS CKT CB LOCATION OF PANELBOARD AND METERING. KVA ...... ....... OTHER LTG I LOAD SERVED REC P OLE .... ......... :TRIP N0. ........... ........: A B N0. IP .,,..:.:.....: POLE POLE LOAD SERVED ....::... .:..... REC : .._�,.,... LTG .::.. OTHER ............. 1 92LTG, EXTERIOR 20 E 1 1 2 20 1 LTG EXTERIOR 1.92 0.24 a ;LTG, EXTERIOR, PHOTOCELL 20 1 3 4 20 1 1 SPARE ! w 0.36 j RECEPT., LTG., HANGAR .:..:. 20 1 1 .. 5 6 20 ._............. 1 RECEPT., LTG., HANGAR 0.36 0.38 W... ......._»...."..-_...__...... 1,38-1 ]"1"0, TORIZED AIRCRAFT DOOR 2HP 20 1._ 2 7 K 8 20 2 W _..._.......................... .»....._......».»..» MOTORIZED AIRCRAFT DOOR 2HP W W--._-_. » .............. 1.38 i 1.38 ;----- ---<--- 9 10 ---:--- ----- x 1.38 ....... 1 038 0.36 ..;. RECEPT., LTG., HANGAR ». ...................... 20 = 1 11 12 20 1 RECEPT., LTG., HANGAR 0.36 `= 0.38 ........ 1.38 » »» _ _ =MOTORIZED AIRCRAFT DOOR 2H _ .H2O , ........................... 2 13 .............. 14 ......... 20 1 2 ....... MOTORIZED AIRCRAFT DOOR (2HP) mm :' 38.._.:. 1.38 i - ---- --- ; --- 1 5 16 --- � --- ----- F i 0.36 RECEPT., LTG., HANGAR 20 3 1 17 18 20 1 RECEPT., LTG., HANGAR F 0.36 € 0.38 11 .1.38 1 38 L MOTORIZED AIRCRAFT DOOR 2HP . _ 20 2 19 ..... 20 . 20 2 MOTORIZED AIRCRAFT DOOR 2HP 11.38 1.38 ----- -- < --- 21 ..:... 22 -- 4 - .....- --- »� 1.38 : _._. ..:_::.:n.:::.:.... ».....W.........._» 0.38 1 036..1 RECEPT.-..LTG- HANGAR.... . ........... l..__..RECEPT.,..:LTG., ..:.::::::..::.:. ...... ........: . ..::.: - ::....:..... HANGAR :.: 0.36 0.38...._�....W__.._.. 1..38 ...... 4 . ................... .»_....20..._k___.1------....23 ! MOTORIZED AIRCRAFT DOOR (2HP) rr rrr., r r ., r 20 2 . 25 �...-_24 26 ._20 20 2 ..W .W.» ............... MOTORIZED AIRCRAFT DOOR 2HP ... � ; 1.38 1.38 _----- E --- < --- k 27 28 - - --- ......... ..... .. _ ..._.. ...... ----- . k 1.38 0.38 w0 ...0 36 ; RECEPT., LTG., HANGAR_....,...:..... _.::::....:. 20 I 1 29 20 1 RECEPT., TG LTG., HA 0.36 i 0.38.... �.............. 1.38 = MOTORIZED AIRCRAFT DOOR 2HP 1 20 2 ... 31 _.. ..»._w»..... 32 20 . 2 ..::.:NGAR MOTORIZED AIRCRAFT DOOR (2HP 1.38 1:.:38 33 34 - -:: 1.38 0.38 ... ........ ............................... 0.36 = RECEPT., LTG., HANGAR 20 1 .:.....:.............. 35 36 ........, _ 20 .... 1 ..... ........ .............................. RECEPT., LTG., HANGAR ...... 0.36 `: ....... 0.38 ,::::. 1.38 kk = MOTORIZED AIRCRAFT DOOR 2HP ......... ......... »....�.. ....... , 20 2 .... . 37 .......................... w.:...,,.....:,..... 38 20 ...... 2 MOTORIZED AIRCRAFT DOOR (2HP ...................._. ..... ....�....__. .. 1.38 .1.38... i 38=SPARE i --- --- 39 40 -- ---LSPAIR_ 20_;_._._. 41_�.4220 1Ery PROVIDE: CONNECTED KVA 4.32 8.64 33.12 HACR TYPE CIRCUIT BREAKERS SERVING HVAC EQUIPMENT DEMAND FACTOR 1.0 " 1.25 0.50 UPDATED TYPEWRITTEN DIRECTORY DEMAND KVA 4.32 10.8 16.56 SURGE ARRESTER TOTAL DEMAND WA 131.0` �-BX DEMAND AMPS 132.0 ' LBX-3& i�Q) -- -� 2 LBX-3 34 0 2 2 L8X-26:28 ® A A A» A A A A A A LBX-36 LBX-30 LBX-24 ' A A A LJ HA,.- .... A A A LBX-35 i \ � \ A A � 2 =-37:3® CID A A A A A A % 81-29 „ LOBI -23 ILE1L 3 A A A A A A \ Y LBX-31:33 ®\' 22 ��2�, / LBX-25:27® H 3 i K u. 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A g k I i i i ` THEY PENETRATE E k #5j 3 NOTED OR SPECIFIED OTHERWISE 3. ALL EXIT AND EMERGENCY BATTERY BALLASTS OF LIGHT FIXTURES TO BE CONNECTED AHEAD OF LOCAL SWITCHING. 4. PROVIDE AN EXTERIOR WALL FLUSH MOUNTED PHOTOCELL AT THE NORTHWEST CORNER OF THIS BUILDING FOR CONTROL OF LIGHT FIXTURES TYPE 'K' AND W. INTERMATIC JK4321 C o OR EQUAL INSTALL AS HIGH AS POSSIBLE 5. ALL RECEPTACLES AND ELECTRICAL DEVICES WITHIN AIRCRAFT HANGAR SPACE TO BE INSTALLED AT +48' A.F.F. TO THE BOTTOM OF EACH DEVICE ALL CONDUIT AND FITTINGS ROUTED BELOW 18' A.F.F. TO BE IXPLOSIONPROOF TYPE KEY NOTES: OM� PROVIDE 30A, 24OV, 14, NEMA L6-30 TWISTLOCK RECEPTACLE IN SURFACE MOUNTED METAL BACKBOX AND TYPE SJO 30/3 CORD WITH PLUG FOR THE AIRCRAFT OVERHEAD DOOR MOTOR. INSTALL RECEPTACLE AT +48' A.F.F. (TYP. OF 12). LOCATION OF PANELBOARD AND METERING. C K K K LBX-3& i�Q) -- -� 2 LBX-3 34 0 2 2 L8X-26:28 ® A A A» A A A A A A LBX-36 LBX-30 LBX-24 ' A A A LJ HA,.- .... A A A LBX-35 i \ � \ A A � 2 =-37:3® CID A A A A A A % 81-29 „ LOBI -23 ILE1L 3 A A A A A A \ Y LBX-31:33 ®\' 22 ��2�, / LBX-25:27® H 3 i K u. 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A g k I i i i ` THEY PENETRATE E k #5j 3 i w.% . K GENERAL ELECTRICAL PLAN NOTES 3 i C__� 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE WALLS, FLOORS OR CEILINGS i i i ` THEY PENETRATE 2. ALL HOMERUNS TO BE 10 THHN CU. IN 3 C. UM UNLESS SHOWN, i� %T� / 4 EMT MINIM H WN NOTED OR SPECIFIED OTHERWISE 3. ALL EXIT AND EMERGENCY BATTERY BALLASTS OF LIGHT FIXTURES TO BE CONNECTED AHEAD OF LOCAL SWITCHING. 4. PROVIDE AN EXTERIOR WALL FLUSH MOUNTED PHOTOCELL AT THE NORTHWEST CORNER OF THIS BUILDING FOR CONTROL OF LIGHT FIXTURES TYPE 'K' AND W. INTERMATIC JK4321 C o OR EQUAL INSTALL AS HIGH AS POSSIBLE 5. ALL RECEPTACLES AND ELECTRICAL DEVICES WITHIN AIRCRAFT HANGAR SPACE TO BE INSTALLED AT +48' A.F.F. TO THE BOTTOM OF EACH DEVICE ALL CONDUIT AND FITTINGS ROUTED BELOW 18' A.F.F. TO BE IXPLOSIONPROOF TYPE KEY NOTES: OM� PROVIDE 30A, 24OV, 14, NEMA L6-30 TWISTLOCK RECEPTACLE IN SURFACE MOUNTED METAL BACKBOX AND TYPE SJO 30/3 CORD WITH PLUG FOR THE AIRCRAFT OVERHEAD DOOR MOTOR. INSTALL RECEPTACLE AT +48' A.F.F. (TYP. OF 12). LOCATION OF PANELBOARD AND METERING. LBX-& 10 LN -20:22 ® 2 2 __2�� '.• /X -EM A A KA A A A \ A r LM -18 LE181 .2 LBB1-6 ' A A A 5 A A A 3 E VM PHOTOCELL LBX-1 ?�Oh` 2OV, 10, 31M A A A A AA A A A VIA "TOCELL k g TOPO&1MBCU.N2'C. 1T) �'�+ �-•. ` k POKER CO.'S 1RAR i k LBX-17 LBX-11 LBB1-5 i 4: #� i3 f� 3 A A A JA A A / A A A ,... E%AM LOX -19.21 LBX-7:9® LBX-13:15 XEN VIA PHOTOCELL K SOUTHEAST RAMP - PHASE 2A 12 -UNIT LARGE BOX HANGAR - ELECTRICAL FLOOR PLAN SCALE: 3/32" =1'-0" DISCLAIMER NOTICE: THIS DOCUMENT CONTAINS PRIVILEGED AND CONFIDENTIAL. INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY 'AZ POWER SYSTEMS' FOR THE USE OF THE INTENDED RECIPIENT, AND FOR AN INTENDED PURPOSE ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN CONSENT OF 'AZ POWER SYSTEMS' IS STRICTLY PROHIBITED. cxn 3 i C__� k E k i i i ` 3 SOUTHEAST RAMP - PHASE 2A 12 -UNIT LARGE BOX HANGAR - ELECTRICAL FLOOR PLAN SCALE: 3/32" =1'-0" DISCLAIMER NOTICE: THIS DOCUMENT CONTAINS PRIVILEGED AND CONFIDENTIAL. INFORMATION, ALL OF WHICH IS EXPRESSLY PROVIDED BY 'AZ POWER SYSTEMS' FOR THE USE OF THE INTENDED RECIPIENT, AND FOR AN INTENDED PURPOSE ANY DISTRIBUTION, REPRODUCTION, OR OTHER USE OF THIS DOCUMENT IN WHOLE OR IN PART, WITHOUT THE EXPRESS WRITTEN CONSENT OF 'AZ POWER SYSTEMS' IS STRICTLY PROHIBITED. cxn C__� �E-4 O o w � OM� -Q' C t..t EXISTING HANGAR f FF. EL. 28.50 w:. EXISTING, HANGAR, µ FF. EL. 28.50 (..:., .mow } ..: .:.. �..... ..... .... ... ..„ .._., EXISTING HANGAR FF. ,EL. 28.50, k::.. .:.:E ?.. �... ..:..� # .....i L .:::.. f EXISTING HANGAR r.. ��° _� ��- XITING AIGAR w w r . E E � f..:. ; ....E FF...f EL.; 28.50 E 1 '- F. �28.5Q ........ .........I :.. i �s PROPOSED HANGAR FF. EL. 128.50 A T PRO OSED HAN�AR F. EL. 28.$0 UE PRIMARY CO . .. ......... ... _. ...... € .... it I FF. EL. 28 50 LB3 PRO OSED HANGAR 13 F. EL. 28..r0 ELECTRICAL SITE PLAN -b EXISTING HANGAR FF. EU 28.50 F c io... .,.....f E y .. --------------- �.....': EXISTING HANGAR FF. EL. 28.50 ., ,.. 5 EXISTING' HANGAR FF, EL,'28.50 PROPOSED HANGAR FF. EL. 28.50 f GENERAL ELEGi CAL NOTES: " F s 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE i;fFa WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.). EXISTING HANGAR ` FF. EL. 28.50 .. 2. ALL HOMERUNS TO BE #10 THHN/THWN CU. IN 3/4 EMT C. MINIMUM, ' I UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE. �s 3. ALL ELECTRICAL EQUIPMENT SHOWN DASHED IS EXISTING TO REMAIN, UNLESS SHOWN OR NOTED OTHERWISE (TYP.). fl ., 4. FINAL LOCATION OF POWER AND TELECOMMUNICATIONS OUTLETS TO BE ..... ...... : :..; ..:;..:;......,,.,, _....:.. COORDINATED WITH THE OWNER PRIOR TO ROUGH -IN. 5. ALL TERMINATED ENDS OF EMTPY UNDERGROUND OR STUBBED -UP E; CONDUIT TO BE CAPPPED AND SEALED. PROVIDE TWO NYLON PULLSTRINGS IN EACH CONDUIT FOR FUTURE CABLE PULLS. EXISTING HANGAR£€ " FF. EL. 28.50 5. ALL SECONDARY CONDUIT TO BE BURIED A MINIMUM OF 24 BELOW FINISHED GRADE WITHIN TRAFFIC RATED AREAS, AND 18" BELOW FINISHED GRADE IN NON -TRAFFIC OR LANDSCAPE AREAS (TYP.). C-41 I 6. PRIMARY CONDUIT BURIAL DEPTH PER POWER COS REQUIREMENTS OR 36 m ry BELOW FINISHED GRADE (TYP.). f € E 9.. (TY''.) ? , € f i«Y NOTES: PROPOSE HANGAR FF. EL. 28.50 C2=1 C21 i E f PROPOED HANGAR 1_l /`/{-f' P FF EL �28 50GAR FF. E . 28.50 3 N r a I REMOVE EXISTING PORTION OF BURIED PRIMARY CONDUIT AND REROUTE TO THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER. 2 PROVIDE A METAL STAKE TO IDENTIFY THE LOCATION OF BURIED 2" PRIMARY CONDUIT FOR FUTURE USE. 3 > PROPOSED LOCATION OF POWER CO'S. 240/120V, 10 TRANSFORMER TO SERVE BUILDING(S) AS SHOWN. 4 > PROVIDE 2" SECONDARY CONDUIT FROM THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER TO SERVE BUILDING PANELBOARD. R�> PROVIDE 2'X3' GRADE MOUNTED POLYCRETE PULLBOX (TYP.). R�> PROVIDE TWO (2) 2" AND FOUR (4) 3" BURIED CONDUITS BETWEEN PULLBOXES AS SHOWN. PROVIDE TWO (2) 2" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF TELEPHONE TERMINAL BOARD. STUB -UP +18" A.F.F. R�> PROVIDE THREE (3) 1" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF GATE CONTROL DEVICES AS DIRECTED BY AIRPORT AUTHORITY AND THE OWNER. 9 EXISTING POWER CO.'S PRIMARY CONDUIT TEMRINATION. 10 PROVIDE A WEATHERPROOF CAST OUTLET BOX AND WATERTIGHT FLEXIBLE CONNECTION TO THE EXTERIOR ILLUMINATED SIGN, CONTROLLED BY A PHOTOCELL. VERIFY EXACT LOCATION WITH THE OWNER PRIOR TO ROUGH -IN. SERVICE TO BE PROVIDED VIA 20A/1 P CIRCUIT BREAKER IN PANELBOARD 'C2-1', CIRCUIT 31. FEEDER / CONDUIT SCHEDULE PROPOSED HANGAR FF. EL. 28.5 WIRE SIZE (AWS) MORO SIZE (AWS) CONDUIT SIZE ® 2010 #10 3/4" PROPOSED HANGAR FF. EL. 128.50 A T PRO OSED HAN�AR F. EL. 28.$0 UE PRIMARY CO . .. ......... ... _. ...... € .... it I FF. EL. 28 50 LB3 PRO OSED HANGAR 13 F. EL. 28..r0 ELECTRICAL SITE PLAN -b EXISTING HANGAR FF. EU 28.50 F c io... .,.....f E y .. --------------- �.....': EXISTING HANGAR FF. EL. 28.50 ., ,.. 5 EXISTING' HANGAR FF, EL,'28.50 PROPOSED HANGAR FF. EL. 28.50 f GENERAL ELEGi CAL NOTES: " F s 1. ALL CONDUIT THROUGH WALL, FLOOR OR CEILING PENETRATIONS TO BE SEALED WITH A FIRE RESISTIVE COMPOUND OF SAME FIRE RATING AS THE i;fFa WALLS, FLOORS OR CEILINGS THEY PENETRATE (TYP.). EXISTING HANGAR ` FF. EL. 28.50 .. 2. ALL HOMERUNS TO BE #10 THHN/THWN CU. IN 3/4 EMT C. MINIMUM, ' I UNLESS SHOWN, NOTED OR SPECIFIED OTHERWISE. �s 3. ALL ELECTRICAL EQUIPMENT SHOWN DASHED IS EXISTING TO REMAIN, UNLESS SHOWN OR NOTED OTHERWISE (TYP.). fl ., 4. FINAL LOCATION OF POWER AND TELECOMMUNICATIONS OUTLETS TO BE ..... ...... : :..; ..:;..:;......,,.,, _....:.. COORDINATED WITH THE OWNER PRIOR TO ROUGH -IN. 5. ALL TERMINATED ENDS OF EMTPY UNDERGROUND OR STUBBED -UP E; CONDUIT TO BE CAPPPED AND SEALED. PROVIDE TWO NYLON PULLSTRINGS IN EACH CONDUIT FOR FUTURE CABLE PULLS. EXISTING HANGAR£€ " FF. EL. 28.50 5. ALL SECONDARY CONDUIT TO BE BURIED A MINIMUM OF 24 BELOW FINISHED GRADE WITHIN TRAFFIC RATED AREAS, AND 18" BELOW FINISHED GRADE IN NON -TRAFFIC OR LANDSCAPE AREAS (TYP.). C-41 I 6. PRIMARY CONDUIT BURIAL DEPTH PER POWER COS REQUIREMENTS OR 36 m ry BELOW FINISHED GRADE (TYP.). f € E 9.. (TY''.) ? , € f i«Y NOTES: PROPOSE HANGAR FF. EL. 28.50 C2=1 C21 i E f PROPOED HANGAR 1_l /`/{-f' P FF EL �28 50GAR FF. E . 28.50 3 N r a I REMOVE EXISTING PORTION OF BURIED PRIMARY CONDUIT AND REROUTE TO THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER. 2 PROVIDE A METAL STAKE TO IDENTIFY THE LOCATION OF BURIED 2" PRIMARY CONDUIT FOR FUTURE USE. 3 > PROPOSED LOCATION OF POWER CO'S. 240/120V, 10 TRANSFORMER TO SERVE BUILDING(S) AS SHOWN. 4 > PROVIDE 2" SECONDARY CONDUIT FROM THE PROPOSED LOCATION OF PAD MOUNTED TRANSFORMER TO SERVE BUILDING PANELBOARD. R�> PROVIDE 2'X3' GRADE MOUNTED POLYCRETE PULLBOX (TYP.). R�> PROVIDE TWO (2) 2" AND FOUR (4) 3" BURIED CONDUITS BETWEEN PULLBOXES AS SHOWN. PROVIDE TWO (2) 2" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF TELEPHONE TERMINAL BOARD. STUB -UP +18" A.F.F. R�> PROVIDE THREE (3) 1" CONDUITS FROM THE PULLBOX TO THE FUTURE LOCATION OF GATE CONTROL DEVICES AS DIRECTED BY AIRPORT AUTHORITY AND THE OWNER. 9 EXISTING POWER CO.'S PRIMARY CONDUIT TEMRINATION. 10 PROVIDE A WEATHERPROOF CAST OUTLET BOX AND WATERTIGHT FLEXIBLE CONNECTION TO THE EXTERIOR ILLUMINATED SIGN, CONTROLLED BY A PHOTOCELL. VERIFY EXACT LOCATION WITH THE OWNER PRIOR TO ROUGH -IN. SERVICE TO BE PROVIDED VIA 20A/1 P CIRCUIT BREAKER IN PANELBOARD 'C2-1', CIRCUIT 31. FEEDER / CONDUIT SCHEDULE ID MARK WIRE SIZE (AWS) MORO SIZE (AWS) CONDUIT SIZE ® 2010 #10 3/4" C APIIIC SCALE 30 0 15 30 60 120 ( IN FEET ) > INCH = 60 FT. I O KARYOV, P.E. E #60953 Power Systems Seatrtcal Engineering & Coneutting FL. License /60953 11655 Swift Water Circle Orlando, FL 32817 Phone/Fox: 407.243.6020 azpo wersystems®bellsouth. net DRAWN AEZ CHECKED AEZ DATE JUNE 15, 2006 SCALE AS NOTED PROJECT NO. 24015.3 PHASE 2A HANGARS ELECTRICAL SITE UTILITIES SHEET ES -2.0 4. Cd '—' o U a� 0 o U a� Q � 0 bJ O o U rd w `n 0 b 4-4 Q) c� 2 g o� P;-4 E-1 m . p -!4 b ,b a U ; ; +' ° co Cn cd E P -i o O U) Un DRAWN AEZ CHECKED AEZ DATE JUNE 15, 2006 SCALE AS NOTED PROJECT NO. 24015.3 PHASE 2A HANGARS ELECTRICAL SITE UTILITIES SHEET ES -2.0 4.